Loading...
HomeMy WebLinkAboutFPS2023-00132 (2) F(o 3-col 2 t`�a, '.. ,,, �r4„qs ^ . a s#` "�'f;"'S r. �,.. IVED .. F :**+iNLlk ° 3 ~ FF ' .' y Li 4 ,r s ,� :x.. T4 wr Western States { t t x s F reProtection Co. P'wtectc. 4ce4 aad Ploftette,f POWERED BY API GROUP FIRE PROTECTION PRODUCT SUBMITTAL Port Plastics 7500 SW Tech Center Dr. #100 ����� cOPs1 Portland, OR 97223 0 WSFP Project # LC0917 Prepared By: Alexander Funk Western States Fire Protection 17500 SW 65th Avenue Lake Oswego, OR 97035 Phone: 503.657.5155 Email: Alexander.Funk@wsfp.us X �,.,r x _,. ...v ;. .._ „ _. *.,�- - �"ter � - fia,,,,,, 4.,, . 3.4 .-,==' r; ,' "tom f. vc, rc 4 CONTENTS 1 . Sprinklers 2. Valves 3. Pipe & Fittings 4. Hangers & Supports ii..4-1,,,N1w44, - • cam, c �"+ ti I VIgC !' i�� .-: a Nt sic,'.n-%.- ^`'h< } Jar It) * �f x ^a' mow.....'... SPRINKLERS t Page 1 of 4 STANDARD RESPONSE TECHNICAL DATA UPRIGHT SPRINKLER VK580 (K16.8) (STORAGE-DENSITY/AREA) The Viking Corporation,210 N Industrial Park Drive, Hastings M149058 Telephone:269-945-9501 Technical Services: 877-384-5464 Fax:269-818-1680 Email:techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 1. DESCRIPTION Viking Standard Response Upright Sprinkler VK580 is a thermosensitive glass bulb spray sprinkler available in various temperature ratings to meet design requirements. With a 16.8 nominal K-Factor, the sprinkler provides greater flows at lower pressures than sprinklers with smaller K-Factors. This feature allows reduced pipe sizing for hydraulically calculated sprinkler systems, and provides the higher densities required to allow an increase in the hazard classification of an occupancy. Viking Standard Response Sprinkler VK580 was subjected to full-scale high piled storage fire testing and is cULus Listed and FM Approved for use in protecting high-piled storage. 2. LISTINGS AND APPROVALS e@ix cULus Listed: Category VNIV FM FM Approved: Class 2024 NOTE: This sprinkler is NOT Listed or Approved as a Specific Application Sprinkler. Refer to the Approval Charts Design Criteria for Listing and Approval requirements that must be followed. A WARNING Cancer and Reproductive Harm www P65Warnings ca gov 3. TECHNICAL DATA Specifications: Available since 2004. Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 3/4"(20 mm) NPT Nominal K-Factor: 16.8 U.S. (242 metric*) Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to-65°F (-55 °C) Overall Length: 2-7/16"(62 mm) Material Standards: Sprinkler Frame: Brass UNS-C84400 Deflector: Phosphor Bronze UNS-051000 Bulb: Glass, nominal 5 mm diameter Pip Cap: Brass UNS-C31600 or Brass UNS-C31400 Compression Screw: Brass UNS-C36000 Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Ordering Information: Refer to Table 1. 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, when the temperature around the sprinkler reaches its operating temperature, the heat-sensitive liquid in the glass bulb expands, causing the bulb to shatter, releasing the pip cap and sealing spring assembly.Water flowing through the sprinkler orifice strikes the sprinkler deflector,forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection,Testing and Maintenance requirements. 7. AVAILABILITY The Viking Model VK580 Sprinkler is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Form No. F_041904 22.04.14 Rev 22.1 Replaces Form No. F_041904 Rev 20.1 (Updated FM references to non-storage sprinklers.) ( 1 Page 2 of 4 STANDARD RESPONSE NIKING, TECHNICAL DATA UPRIGHT SPRINKLER VK580 (K16.8) (STORAGE-DENSITY/AREA) The Viking Corporation,210 N Industrial Park Drive, Hastings MI 49058 Telephone:269-945-9501 Technical Services: 877-384-5464 Fax:269-818-1680 Email:techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com TABLE 1: SPRINKLER ORDERING INFORMATION Instructions: Using the sprinkler base part number, (1) add the suffix for the desired Finish (2) add the suffix for the desired Temperature Rating. r.14CIt!,',44::;..itt-,7,',.";-f:,. terepiP.%:. 1-.':-yytiz. ,,,,,77-':--f:':7',4wei4 Av,0104.VV:47'44",--'--t-- rivn---f-k-GeMeakrir,,. , 41741' 4#' 'fi x.A.T'.....A,' &d41 I4IIIF1E, :...:r 12739 3/4 Brass A Ordinary 155 °F (68 °C) Red 100 °F (38 °C B Intermediate 175 °F 79 °C Yellow 150 °F 65 °C D Intermediate 200 °F 93 °C Green 150 °F 65 °C E High 286 °F(141 °C) Blue 225°F(107 °C) G Example: 12739AB= 155°F (68°C)Temperature Rated Sprinkler with a standard Brass finish. Sprinkler Wrench: 07297W/B Sprinkler Cabinet: 1. Holds up to 6 sprinklers: 01724A 2. Holds up to 12 sprinklers: 01725A y . : (i@t.,kk'. ...' la 'r„ .' .tr .'a a.. �. i ' 1 ,, .° .. x,? a 1. Part number shown is the base part number.For complete part number,refer to the current Viking price list schedule. 2. The sprinkler temperature rating is stamped on the deflector. 3. Based on NFPA 13, NFPA 13R,and NFPA 13D.Other limits may apply,depending on fire loading,sprinkler location,and other requirements of the Authority Having Jurisdiction.Refer to specific installation standards. 2" (51 mm) r Protective Wrench Flat Clip 2-7/16" (62 mm) i . Figure 1: Sprinkler with Protective Clip and Wrench Figure 2: Sprinkler Dimensions Form No. F_041904 22.04.14 Rev 22.1 Page 3 of 4 STANDARD RESPONSE TECHNICAL DATA UPRIGHT SPRINKLER VK580 (K16.8) (STORAGE-DENSITY/AREA) The Viking Corporation,210 N Industrial Park Drive, Hastings MI 49058 Telephone:269-945-9501 Technical Services:877-384-5464 Fax: 269-818-1680 Email:techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Listings and Approvals' Base Part SIN Sprinkler Thread Size Nominal K-Factor Overall Length (Refer also to Design Criteria below.) Number' Style NPT BSPT U.S. metric2 Inches mm cULus4 NYC 12739A VK580 Upright 3/4" 20 mm 16.8 242 2-7/16 62 Al See Footnote 5. Approved Temperature Ratings Approved Finish A- 155°F(68°C), 175°F(79°C),200°F(93°C),and 286°F(141 °C) 1 -Brass Footnotes 'Base part number shown. For complete part number,refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing.Other approvals may be in process. "Listed by Underwriters Laboratories Inc.for use in the U.S.and Canada. 5 Meets New York City requirements,effective July 1,2008. cULus Listing Reauirements: Standard Response Upright Sprinkler VK580 is cULus Listed for installation in accordance with the latest edition of NFPA 13 for standard upright spray sprinklers: • Designed for use in hazard occupancies up to and including Extra-Hazard Group II for hydraulically calculated wet or dry systems. • The sprinkler installation and obstruction rules contained in NFPA 13 for standard spray upright sprinklers must be followed. &4Q Sprinkler VK580 is cULus Listed for use in High-Piled Storage Occupancies as defined in NFPA 13: • This sprinkler may be used for the protection of solid piled, palletized,rack storage(single,double,multiple-row and portable), bin box,and shelf storage including,but not limited to: encapsulated or unencapsulated Class I-IV and Group A or B plastics, cartoned,expanded or unexpanded, as well as exposed unexpanded. • For hydraulically calculated wet or dry systems per NFPA 13 with a minimum operating pressure of 7 psi(0.5 bar). • Use the standard sprinkler positioning requirements and area/density sprinkler protection criteria provided in NFPA 13 for High-Piled Storage Occupancies. IMPORTANT: Always refer to Bulletin Form No. F_091699 -Care and Handling of Sprinklers.Also refer to Form No. 080614 for general care, installation,and maintenance information.Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data,the appropriate standards of NFPA, FM Global, LPCB,APSAD,VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances,and standards,whenever applicable. Form No. F 041904 22.04.14 Rev 22.1 t 1 Page 4 of 4 NII(ING STANDARD RESPONSE TECHNICAL DATA UPRIGHT SPRINKLER VK580 (K16.8) (STORAGE-DENSITY/AREA) The Viking Corporation,210 N Industrial Park Drive, Hastings MI 49058 Telephone:269-945-9501 Technical Services:877-384-5464 Fax:269-818-1680 Email:techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Base Part SIN Thread Size Nominal K-Factor Overall Length FM Approvals3 Number' NPT BSPT U.S. metric2 Inches mm (Refer also to Design Criteria below.) 12739A VK580 3/4" 20 mm 16.8 242 2-7/16 62 Al Approved Temperature Ratings Approved Finish A-155°F(68°C), 175°F(79°C),200°F(93°C),and 286°F(141 °C) 1 -Brass Footnotes 'Base part number shown. For complete part number,refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 'This table shows the listings and approvals available at the time of printing.Other approvals may be in process. FM Aooroval Requirements: • Sprinkler VK580 is FM Approved for use as a standard response Storage upright sprinkler as indicated in the FM Approval Guide. • Approved storage sprinklers are also FM Approved for use as Non-Storage upright sprinklers. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets(including Data Sheets 2-0 and 8-9). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to:minimum water supply requirements, hydraulic design, ceiling slope and obstructions,minimum and maximum allowable spacing,and deflector distance below the ceiling. NOTE:The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F 091699 -Care and Handling of Sprinklers.Also refer to Form No. 080614 for general care, installation,and maintenance information.Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data,the appropriate standards of NFPA, FM Global, LPCB,APSAD,VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances,and standards,whenever applicable. Form No. F_041904 22.04.14 Rev 22.1 Replaces Form No. F_041904 Rev 20.1 (Updated FM references to non-storage sprinklers.) J } Page 1 of 4 NIKING BULLETIN CARE AND HANDLING OF SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com SPRINKLERS ARE FRAGILE - HANDLE WITH CARE! General Handling and Storage: • Store sprinklers in a cool,dry place. • Protect sprinklers during storage, transport, handling, and after installation. • Use the original shipping containers. DO NOT place sprinklers loose in boxes, bins, f" ' " or buckets. - ' • Keep sprinklers separated at all times. DO NOT allow metal parts to contact sprinkler • ` R ` operating elements. CORRECT INCORRECT For Pre-Assembled Drops: (Original container used) (Placed loose in box) • Protect sprinklers during handling and after installation. • ` • For recessed assemblies, use the protective sprinkler cap(Viking Part Number 10364). Sprinklers with Protective Shields or Caps: • DO NOT remove shields or caps until after sprinkler installation and there no longer is t"f potential for mechanical damage to the sprinkler operating elements. Ct 0 ,, • Sprinkler shields or caps MUST be removed BEFORE placing the system in service! CORRECT INCORRECT • Remove the sprinkler shield by carefully pulling it apart where it is snapped together. (Protected with caps) (Protective caps not used) • Remove the cap by turning it slightly and pulling it off the sprinkler. Sprinkler Installation: • DO NOT use the sprinkler deflector or operating element to start or thread the sprinkler ; into a fitting. • Use only the designated sprinkler head wrench! Refer to the current sprinkler tech- nical data page to determine the correct wrench for the model of sprinkler used. • DO NOT install sprinklers onto piping at the floor level. CORRECT INCORRECT (Piping is in place at the (Sprinkler at floor level) • Install sprinklers after the piping is in place to prevent mechanical damage. ceiling) • DO NOT allow impacts such as hammer blows directly to sprinklers or to fittings, pipe, ry or couplings in close proximity to sprinklers. Sprinklers can be damaged from direct or ,.. Ck X:' indirect impacts. • DO NOT attempt to remove drywall, paint, etc., from sprinklers. • Take care not to over-tighten the sprinkler and/or damage its operating parts! 3 Maximum Torque: 1/2" NPT: 14 ft-lbs. (19.0 N-m) CORRECT INCORRECT 3/4" NPT: 20 ft-lbs. (27.1 N-m) (Special installation (Designated wrench not 1" NPT: 30 ft-lbs. (40.7 N-m) wrenches) used) /� WARNING:Cancer and Reproductive Harm / l www.P65Warnings.ca.gov Any sprinkler with a loss of liquid from the glass bulb or damage to the fusible element should be destroyed. Never install sprinklers that have been dropped,damaged,or exposed to temperatures exceeding the maximum ambient temperature allowed.Sprinklers that have been painted in the field must be replaced per NFPA 13. Protect sprinklers from paint and paint overspray in accordance with the installation standards. Do not clean sprinklers with soap and water, ammonia, or any other cleaning fluid. Do not use adhesives or solvents on sprinklers or their operating elements. Refer to the appropriate technical data page and NFPA standards for complete care, handling, installation,and maintenance instructions. For additional product and system information Viking data pages and installation instructions are available on the Viking Web site at www.vikinggroupinc.com. Form No. F_091699 18.10.11 Rev 16.1.P65 Replaces Form No. F_091699 Rev 16.1 (Added P65 Warning) C J Page 2 of 4 BULLETIN CARE AND HANDLING OF SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com PROTECTIVE SPRINKLER SHIELDS AND CAPS General Handling and Storage: Many Viking sprinklers are available with a plastic protective cap or shield temporarily covering the operating elements. The snap- on shields and caps are factory installed and are intended to help protect the operating elements from mechanical damage during shipping, storage, and installation. NOTE: It is still necessary to follow the care and handling instructions on the appropriate sprin- kler technical data sheets*when installing sprinklers with bulb shields or caps. WHEN TO REMOVE THE SHIELDS AND CAPS: NOTE: SHIELDS AND CAPS MUST BE REMOVED FROM SPRINKLERS BEFORE PLACING THE SYSTEM IN SERVICE! Remove the shield or cap from the sprinkler only after checking all of the following: • The sprinkler has been installed*. • The wall or ceiling finish work is completed where the sprinkler is installed and there no longer is a potential for mechanical damage to the sprinkler operating elements. SHIELDS AND CAPS MUST BE REMOVED FROM SPRINKLERS BEFORE PLACING THE SYSTEM IN SERVICE! yj • Figure 1: Sprinkler shield being Figure 2: Sprinkler cap being Figure 3:Sprinkler cap being re- removed from a pendent sprinkler. removed from a pendent sprinkler. moved from and upright sprinkler. HOW TO REMOVE SHIELDS AND CAPS: No tools are necessary to remove the shields or caps from sprinklers. DO NOT use any sharp objects to remove them! Take care not to cause mechanical damage to sprinklers when removing the shields or caps. When removing caps from fusible ele- ment sprinklers, use care to prevent dislodging ejector springs or damaging fusible elements. NOTE: Squeezing the sprinkler cap excessively could damage sprinkler fusible elements. • To remove the shield, simply pull the ends of the shield apart where it is snapped together. Refer to Figure 1. • To remove the cap, turn it slightly and pull it off the sprinkler. Refer to Figures 2 and 3. NOTICE Refer to the current sprinkler technical data page to determine the correct sprinkler wrench for the model of sprinkler used. Never install sprinklers that have been dropped,damaged,or exposed to temperatures in excess of the maximum ambient temperature allowed. * Refer to the appropriate current technical data pages for complete care, handling, and installation instructions. Data pages are included with each shipment from Viking or Viking distributors.They can also be found on the Web site at www. vikinggroupinc.com. Form No. F_091699 18.10.11 Rev 16.1.P65 Page 3 of 4 NIKING BULLETIN CARE AND HANDLING OF SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Ao*tibw CONCEALED COVER ASSEMBLIES ARE FRAGILE! TO ASSURE SATISFACTORY PERFORMANCE OF THE PRODUCT, HANDLE WITH CARE. Concealed Sprinkler and Adapter aaMx ' + Assembly(Protective Cap Removed) • j ` t Sri r 't t r � af' 11. x}' % F 74, Concealed Sprinkler and Adapter Cover Plate Assembly ,. 44"7., "^'= Tr` ; Assembly with Protective Cap (Pendent Cover 12381 shown) GENERAL HANDLING AND STORAGE INSTRUCTIONS: • Do not store in temperatures exceeding 100°F(38°C).Avoid direct sunlight and confined areas subject to heat. • Protect sprinklers and cover assemblies during storage,transport, handling, and after installation. --Use original shipping containers. --Do not place sprinklers or cover assemblies loose in boxes, bins,or buckets. • Keep the sprinkler bodies covered with the protective sprinkler cap any time the sprinklers are shipped or handled, during testing of the system, and while ceiling finish work is being completed. • Use only the designated Viking recessed sprinkler wrench(refer to the appropriate sprinkler data page)to install these sprinklers.NOTE:The protective cap is temporarily removed during installation and then placed back on the sprinkler for protection until finish work is completed. • Do not over-tighten the sprinklers into fittings during installation. • Do not use the sprinkler deflector to start or thread the sprinklers into fittings during installation. • Do not attempt to remove drywall, paint,etc.,from the sprinklers. • Remove the plastic protective cap from the sprinkler before attaching the cover plate assembly. PROTECTIVE CAPS MUST BE REMOVED FROM SPRINKLERS BEFORE PLACING THE SYSTEM IN SERVICE! Refer to the appropriate current technical data pages for complete care, handling, and installation instructions. Data pages are included with each shipment from Viking or Viking distributors.They can also be found on the Web site at www. vikinggroupinc.com. Form No. F_091699 18.10.11 Rev 16.1.P65 t S Page 4 of 4 BULLETIN CARE AND HANDLING OF SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com USE THE FOLLOWING PRECAUTIONS WHEN HANDLING WAX-COATED SPRINKLERS Many of Viking's sprinklers are available with factory-applied wax coating for corrosion resistance.These sprinklers MUST receive appropriate care and handling to avoid damaging the wax coating and to assure satisfactory performance of the product. General Handling and Storage of Wax-Coated Sprinklers: • Store the sprinklers in a cool, dry place(in temperatures below the maximum ambient temperature allowed for the sprinkler temperature rating. Refer to Table 1 below.) • Store containers of wax-coated sprinklers separate from other sprinklers. • Protect the sprinklers during storage,transport, handling,and after installation. • Use original shipping containers. • Do not place sprinklers in loose boxes, bins,or buckets. Installation of Wax-Coated Sprinklers: Use only the special sprinkler head wrench designed for installing wax-coated Viking sprinklers (any other wrench may damage the unit). • Take care not to crack the wax coating on the units. • For touching up the wax coating after installation,wax is available from Viking in bar form. Refer to Table 1 below.The coating MUST be repaired after sprinkler installation to protect the corrosion-resistant properties of the sprinkler. • Use care when locating sprinklers near fixtures that can generate heat. Do not install sprinklers where they would be exposed to temperatures exceed- ing the maximum recommended ambient temperature for the temperature rating used. • Inspect the coated sprinklers frequently soon after installation to verify the integrity of the corrosion resistant coating.Thereafter,inspect representative samples of the coated sprinklers in accordance with NFPA 25.Close up visual inspections are necessary to determine whether the sprinklers are being affected by corrosive conditions. TABLE 1 155 °F (68 °C)/ 165 °F(74 °C) 02568A 148 °F (64 °C) 100 °F (38 °C) Light Brown 175 °F (79 °C) 04146A 161 °F (71 °C) 150 °F (65°C) Brown 200 °F (93 °C) 04146A 161 °F (71 °C) 150 °F (65°C) Brown 220 °F (104 °C) 02569A 170 °F (76 °C) 150 °F (65 °C) Dark Brown 286 °F (141 °C) 02569A 170 °F (76 °C) 150 °F (65°C) Dark Brown 'Based on NFPA-13.Other limits may apply,depending on fire loading,sprinkler location,and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Never install sprinklers that have been dropped, damaged, or exposed to temperatures in excess of the maximum ambi- ent temperature allowed. Refer to the appropriate current technical data pages for complete care, handling, and installation instructions. Data pages are included with each shipment from Viking or Viking distributors.They can also be found on the Web site at www. vikinggroupinc.com. Form No. F_091699 18.10.11 Rev 16.1.P65 Replaces Form No. F_091699 Rev 16.1 (Added P65 Warning) Page 1 of 3 NIKIING TECHNICAL DATA SPRINKLER OVERVIEW The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION Viking fire sprinklers consist of a threaded frame with a specific waterway or orifice size and a deflector for distributing water in a specified pattern.A closed or sealed sprinkler refers to a complete assembly, including the thermosensitive operating element.An open sprinkler does not use an operating element and is open at all times. The distribution of water is intended to extinguish a fire or to control its spread. Viking sprinklers are available in several models and styles. Refer to specific sprinkler technical data pages for available styles, finishes, temperature ratings, thread sizes, and nominal K-Factors for the particular model selected. 2. LISTINGS AND APPROVALS Refer to the Approval Charts on the appropriate sprinkler technical data page(s) and/or /� WARNING Cancer and Reproductive Harm approval agency listings. \ www P65Warmngs ca gov 3. TECHNICAL DATA Pressure Ratings: Maximum allowable water working pressure is 175 psig (12 Bar) unless rated and specified for high water working pressure [250 psig (17.2 bar)]. Sprinkler Identification: Viking sprinklers are identified and marked with the word "Viking", the sprinkler identification number(SIN) consisting of"VK" plus a three digit number", the model letter, and the year of manufacture. Available Finishes: Viking sprinklers are available in several decorative finishes. Some models are available with corrosion-resistant coatings or are fabricated from non-corrosive material. Refer to the sprinkler technical data page for additional information. Available Temperature Ratings: Viking sprinklers are available in several temperature ratings that relate to a specific temperature classification.Applicable installa- tion rules mandate the use and limitations of each temperature classification. In selecting the appropriate temperature classifica- tion, the maximum expected ceiling temperature must be known. When there is doubt as to the maximum temperature at the sprinkler location, a maximum-reading thermometer should be used to determine the temperature under conditions that would show the highest readings to be expected. In addition, recognized installation rules may require a higher temperature classifica- tion,depending upon sprinkler location,occupancy classification,commodity classification,storage height,and other hazards. In all cases,the maximum expected ceiling temperature dictates the lowest allowable temperature classification. Sprinklers located immediately adjacent to a heat source may require a higher temperature rating. K-Factors: Viking sprinklers are available in several orifice sizes with related K-Factors.The orifice is a tapered waterway and, therefore, the K-Factor given is nominal. Nominal U.S. K-Factors are provided in accordance with the 1999 edition of NFPA 13, Section 3-2.3. Refer to the specific data page for appropriate K-Factor information. Available Styles: Viking sprinklers are available for installation in several positions as indicated by a stamping on the deflector. The deflector style dictates the appropriate installation position of the sprinkler; it breaks the solid stream of water issuing from the sprinkler orifice to form a specific spray pattern. The following list indicates the various styles and identification of Viking sprinklers. UPRIGHT SPRINKLER:A sprinkler intended to be installed with the deflector above the frame so water flows upward through the orifice, striking the deflector and forming an umbrella-shaped spray pat- tern downward. Marked"SSU"(Standard Sprinkler Upright)or"UPRIGHT" on the deflector. Viking Technical Data may be found on PENDENT SPRINKLER: A sprinkler intended to be oriented with the deflec- Viking Corporation's Web site at tor below the frame so water flows downward through the orifice, striking http://www.vikinggroupinc.com. the deflector and forming an umbrella-shaped spray pattern downward. The Web site may include a more recent Marked "SSP" (Standard Sprinkler Pendent) or "PENDENT" on the de- edition of this Technical Data Page. flector. CONVENTIONAL SPRINKLER:An "old style" sprinkler intended to be installed with the deflector in either the upright or pendent position. The deflector provides a spherical type pattern with 40 to 60 percent of the water initially directed downward and a proportion directed upward. Must be installed in accordance with installation rules for conventional or old style sprinklers. DO NOT USE AS A REPLACEMENT FOR STANDARD SPRAY SPRINKLERS. Marked "C U/P" (Conventional Upright/Pendent)on the deflector. Form No. F_080814 18.12.06 Rev 14.1.P65 Replaces Form No. F_080814 Rev 14.1 (Added P65 Warning.) r s Page 2 of 3 NIKING TECHNICAL DATA SPRINKLER OVERVIEW The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com VERTICAL SIDEWALL(VSW)SPRINKLER:A sprinkler intended for installation near the wall and ceiling.The deflector provides a water spray pattern outward in a quarter-spherical pattern and can be installed in the upright or pendent position with the flow arrow in the direction of discharge. Marked "SIDEWALL" on the deflector with an arrow and the word "FLOW". (Note: Some vertical sidewall sprinklers can only be installed in the upright or pendent position—in this case,the sprinkler will also be marked "UPRIGHT"or"PENDENT') HORIZONTAL SIDEWALL(HSW)SPRINKLER:A sprinkler intended for installation near the wall and ceiling.The special deflector provides a water spray pattern outward in a quarter-spherical pattern. Most of the water is directed away from the nearby wall with a small portion directed at the wall behind the sprinkler.The top of the deflector is oriented parallel with the ceiling or roof. The flow arrows point in the direction of discharge. Marked "SIDEWALL"and "TOP"with an arrow and the word "FLOW". EXTENDED COVERAGE (EC) SPRINKLER: A spray sprinkler designed to discharge water over an area having the maximum dimensions indicated in the individual listings. Maximum area of coverage, minimum flow rate,orifice size,and nominal K-Factor are specified in the individual listings. EC sprinklers are intended for Light-Hazard occupancies with smooth,flat, horizontal ceil- ings unless otherwise specified. In addition to the above markings, the sprinkler is marked "EC". QUICK RESPONSE (QR) SPRINKLER: A spray sprinkler with a fast- actuating operating element. The use of quick response sprinklers may be limited due to occupancy and hazard. Refer to the Authority Having Jurisdiction (AHJ) prior to installing. QUICK RESPONSE EXTENDED COVERAGE (QREC) SPRINKLER:A spray sprinkler designed to discharge water over an area having the maximum dimensions indicated in the individual listing. This is a sprinkler with an operating element that meets the criteria for quick response. QREC sprinklers are only intended for Light Hazard occupancies. The sprinkler is marked "QREC". FLUSH SPRINKLER: A decorative spray sprinkler intended for installation with a concealed piping system. The unit is mounted flush with the ceiling or wall, with the fusible link exposed. Upon actuation, the deflector extends beyond the ceiling or wall to distribute water discharge. The sprinkler is marked "SSP", "PEND", or"SIDEWALL"and "TOP". CONCEALED SPRINKLER:A decorative spray sprinkler intended for installation with a concealed piping system. The sprinkler is hidden from view by a cover plate installed flush with the ceiling or wall. During fire conditions, the cover plate detaches, and upon sprinkler actuation, the deflector extends beyond the ceiling or wall to distribute water discharge.The sprinkler is marked "SSP", "PEND", or"SIDEWALL"and "TOP". RECESSED SPRINKLER:A spray sprinkler assembly intended for installation with a concealed piping system.The assembly con- sists of a sprinkler installed in a decorative adjustable recessed escutcheon that minimizes the protrusion of the sprinkler beyond the ceiling or wall without adversely affecting the sprinkler distribution or sensitivity. Refer to the appropriate technical data page for allowable sprinkler models, temperature ratings, and occupancy classifications. DO NOT RECESS ANY SPRINKLER NOT LISTED FOR USE WITH THE ESCUTCHEON. CORROSION-RESISTANT SPRINKLER: A special service sprinkler with non-corrosive protective coatings, or that is fabricated from non-corrosive material,for use in atmospheres that would normally corrode sprinklers. DRY SPRINKLER:A special-service sprinkler intended for installation on dry pipe systems or wet pipe systems where the sprinkler is subject to freezing temperatures. The unit consists of a sprinkler permanently secured to an extension nipple with a sealed inlet end to prevent water from entering the nipple until the sprinkler operates. The unit MUST be installed in a tee fitting. Dry upright sprinklers are marked with the "B" dimension [distance from the face of the fitting (tee) to the top of the deflector]. Dry pendent and sidewall sprinklers are marked with the "A" dimension [the distance from the face of fitting (tee) to the finished surface of the ceiling or wall]. LARGE DROP SPRINKLER:A type of special application sprinkler used to provide fire control of specific high-challenge fire haz- ards. Large drop sprinklers are designed to produce an umbrella-shaped spray pattern downward with a higher percentage of "large" water droplets than standard spray sprinklers. The sprinkler has an extra-large orifice with a nominal K-Factor of 11.2. Marked "HIGH CHALLENGE"and "UPRIGHT". EARLY SUPPRESSION FAST-RESPONSE(ESFR)SPRINKLER:A sprinkler intended to provide fire suppression of specific high- challenge fire hazards through the use of a fast response fusible link, 14.0, 16.8,or 25.2 nominal K-Factor, and special deflector. ESFR sprinklers are designed to produce high-momentum water droplets in a hemispherical pattern below the deflector. This permits penetration of the fire plume and direct wetting of the burning fuel surface while cooling the atmosphere early in the development of a high-challenge fire. Marked "ESFR"and "UPRIGHT"or"PEND". INTERMEDIATE LEVEL/RACK STORAGE SPRINKLER: A standard spray sprinkler assembly designed to protect its operating element from the spray of sprinklers installed at higher elevations. The assembly consists of a standard or large orifice upright or pendent sprinkler with an integral upright or pendent water shield and guard assembly. Use only those sprinklers that have been tested and listed for use with the assembly. Refer to the technical data page for allowable sprinkler models. RESIDENTIAL SPRINKLER:A sprinkler intended for use in the following occupancies: one-and two-family dwellings with the fire protection sprinkler system installed in accordance with NFPA 13D; residential occupancies up to four stories in height with the fire protection system installed in accordance with NFPA 13R; and where allowed by the Authority Having Jurisdiction in resi- dential portions of any occupancy with the fire protection system installed in accordance with NFPA 13. Form No. F_080814 18.12.06 Rev 14.1.P65 Page 3 of 3 NIKING TECHNICAL DATA SPRINKLER OVERVIEW The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Residential sprinklers have a unique distribution pattern and utilize a "fast response" heat sensitive operating element. They en- hance survivability in the room of fire origin and are designed to provide a life safety environment for a minimum of ten minutes. For this reason, residential sprinklers must not be used to replace standard sprinklers unless tested for and approved by the Authority Having Jurisdiction. In addition to standard markings,the unit is identified as"RESIDENTIAL SPRINKLER"or"RES". 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION Refer to the appropriate sprinkler technical data page(s). 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. IMPORTANT:Always referto Bulletin Form No.F_091699-Care and Handling of Sprinklers and the appropriate sprin- klergeneral care,installation,and maintenance guide.Viking sprinklers areto be installed in accordancewith the latest edition of Viking technical data,the appropriate standards of NFPA,FM Global,LPCB,APSAD,VdS or other similar organizations,and also with the provisions of governmental codes,ordinances,and standards,wheneverapplicable. The sprinkler technical data page may contain installation requirements specific for the sprinkler model selected. The use of certain types of sprinklers may be limited due to occupancy and hazard. Refer to the Authority Having Jurisdiction prior to installation. Form No. F_080814 18.12.06 Rev 14.1.P65 Replaces Form No. F_080814 Rev 14.1 (Added P65 Warning.) c S Page 1 of 1 NIKING® REGULATORY AND HEALTH BULLETIN WARNINGS The Viking Corporation,210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email:techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 1. DESCRIPTION Regulatory and Health Warnings applying to materials used in the manufacture and construction of fire protection products are provided herin as they relate to legally mandated jurisdictional regions. STATE OF CALIFORNIA, USA Installing or servicing fire protection products such as sprinklers, valves, piping etc. can expose you to chemicals including, but not li- mited to, lead,nickel, butadiene,titaninum dioxide,chromium,carbon black,and acrylonitrile which are known to the State of California to cause cancer or birth defects or other reproductive harm. For more information, go to www.P65Warnings.ca.gov 2. WARRANTY TERMS AND CONDITIONS For details of warranty, refer to Viking's current list price schedule at www.vikinggroupinc.com or contact Viking directly. Form No. F_111218 18.11.15 Rev 18.1 New Bulletin Bulletin 074 January 2023 to Fl FR56 Series Reliabi Quick Response Sprinklers K-factor 5.6(80) Features 3 4 • Standard coverage quick-response sprinklers • Upright, pendent, horizontal sidewall, and vertical sidewall deflectors • Low profile, compact design ti • Available in a wide variety of finishes Product Description Model F1FR56 Pendent Model F1FR56 Upright Reliable Model F1 FR56 series sprinklers are quick-response standard spray automatic fire sprinklers utilizing a sensitive 3.0 mm glass bulb thermal element. �. Pendent and horizontal sidewall sprinklers may be installed exposed or surface mounted using escutcheons such as the Reliable Models B, C, or HB(reference Technical Bulletin 204). When installed recessed or concealed,the Model F1FR56 series • sprinklers are specifically listed with and may only be installed with listed Reliable escutcheons and cover plates. Refer to the Model F1FR56 Vertical Sidewall Model F1FR56 technical information on the following pages for specific listings Horizontal Sidewall for recessed and concealed installations and refer to Figures 5 and 6 for dimensional information. Note:Not all versions of the product are shown. When fitted with an approved water shield,these sprinklers may considered intermediate sprinklers for use in racks, below grated walkways, and other areas where intermediate level sprinklers are required. Note:This bulletin may contain information on New and Legacy Table A provides a summary of the approvals and availability of sprinklers that reflects a dimensional change only.Sprinkler Iden- tification Number(SIN),application, performance, and listings/ specific Model F1 FR series sprinkler configurations.Additional approval are not otherwise affected. Sprinklers with New frames technical information for each sprinkler model is provided on the will include the suffix"N"in the order. following pages. Fl FR Series Sprinkler Summary Table A Sprinkler K-Factor gprKi7psi'h " - Max,Working fissure Model (ipmIbar' " Sprinkler" Orientation Listings&Approvals identification si;(bar) Number(SIN)' Upright cULus,FM,LPCB,VdS, 175(12) RA1425 Intermediate Upright EC,WM,UKCA 250(17)(cULus only) Pendent cULus,FM,LPCB,VdS, 175(12) RA1414 EC,WM,UKCA 250(17)(cULus only) F1FR56 5.6(80) Concealed Pendent cULus,VdS,EC,WM, 175(12) RA1414 UKCA 250(17)(cULus only) Horizontal Sidewall cULus,FM 175(12) RA1435 250(17)(cULus only) Vertical Sidewall cULus,FM,LPCB, 175(12) RA1485 UKCA www.reliablesprinkler.com t 1 Model F1 FR56 Upright Sprinkler SIN RA1425 Technical Specifications Guards&Shields(New Frames) Style:Upright,Intermediate Upright Factory Water Shield(cULus,FM) Threads:1/2"NPT or ISO 7-R1/2 F-1 Guard(cULus,FM) Nominal K-Factor:5.6(80 metric) F-3 Guard with Shield(cULus, FM) Max.Working Pressure: 175 psi(12 bar) Guards and Shields(Legacy Frames) FactoryWater Shield 250 psi(17 bar)(cULus only) Material Specifications C-1 Guard(FM) -.- +frr(ti-rc1 C-3 Guard with Shield(cULus,FM) Thermal Sensor:3 mm Glass Bulb D-1 Guard(cULus) 111 Sprinkler Frame:Brass Alloy D-3 Guard with Shield(cULus) Cap:Bronze Alloy Sealing Washer:Nickel with PTFE Sprinkler Wrench Load Screw:Copper Alloy Model W2 - Deflector:Brass Alloy Model J(New frame with guard installed) Model JD(Legacy frame with guard Sprinkler Finishes installed) -1, - (See Table B) fListings and Approvals Sensitivity cULus Listed Quick response FM Approved LPCB Temperature Ratings VdS 135°F(57°C) EC 155°F(68°C) WM 175°F(79°C) UKCA:0832-UKCA-CPR-S5045 200°F(93°C) 286°F(141°C) Model Fl FR56 Upright Sprinkler Components and Dimensions Figure 1 31/4"[83mm] Load Screw 1 3/8"[33mm] Deflector i rTTrTTT11PA i r TTTiT►� ' Glass Bulb r (3 mm) F1 FR_FIALF_UPR_INT 11111—= _� 2 1/4"[58mm] Wrench Flat 1 RA Cap/Seal Assembly IIMIk ' Threads Shown with Optional Factory Installed Water Shield (Intermediate Upright) Bulletin 074 eliable Page 2 of 9 January 2023 www.reliablesprinkler.com Model F1FR56 Pendent Sprinkler SIN RA1414 Technical Specifications Recessed Escutcheons Style: Model F1 (cULus,LPCB,VdS,CE,WM) Pendent Model F2(cULus,FM,LPCB,VdS,CE, Recessed Pendent WM) Concealed Pendent Model FP(cULus,VdS,CE,WM) Threads:1/2"NPT or ISO 7-R1/2 Nominal K-Factor:5.6(80 metric) Cover Plate Max.Working Pressure: Model CCP(cULus,VdS(2),CE(2)) 175 psi(12 bar) 250 psi(17 bar)(cULus only) Guards&Shields(New Frames?) , 1 Material Specifications F 1 Guard(FM) 4 • Thermal Sensor:3 mm Glass Bulb F-5 Guard/Shield Kit(FM) - .. Sprinkler Frame:Brass Alloy F-7 Guard(cULus) Cap:Bronze Alloy F-8 Guard/Shield Kit(cULus) Sealing Washer:Nickel with PTFE S 1 Shield(cULus,FM) Load Screw:Copper Alloy Guards&Shields(Legacy Frames?) Deflector:Brass Alloy C-1 Guard(FM) Sprinkler Finishes C-5 Guard/Shield Kit(FM) II ,. (See Table B) D-1 Guard(cULus,FM) k D-4 Guard/Shield Kit(FM) Sensitivity D-5 Guard/Shield Kit(cULus,FM) Quick response S-1 Shield(cULus,FM) _ Temperature Ratingst'I Sprinkler Wrenches 135°F(57°C) Model W2(pendent) 155°F(68°C) Model W4(recessed or concealed) 175°F(79°C) Model J(New frame with guard installed) 200°F(93°C) Model JD(Legacy frame with guard 286°F(141°C) installed) Listings and Approvals141 cULus Listed FM Approved LPCB VdS EC WM UKCA:0832-U KCA-CPR-S 5045, 0831-UKCA-CPR-5072(CCP) Notes: 1. 286°F(141°C)temperature rated sprinkler not listed for recessed or concealed use. 2. VdS and CE approval for CCP concealed use is for 155°C(68°C)sprinkler ONLY. 3. Not suitable for recessed or concealed pendent installations. 4. When used surface mounted or exposed.See Recessed Escutcheon and Cover Plate section for specific approvals when installed recessed or concealed. Model F1FR56 Pendent Sprinkler Components and Dimensions Figure 2 3 1/4"[83mm] Threads 1_- FIFN HALF_PEND INT 0d3 I Wrench Flat pi ? 2 1l4"[57mm] Cap/Seal 1 1 Assembly Glass Bulb n (3 mm) ... .., Deflector Load Screw 1"[25mm] Shown with Optional S-1 Water Shield(Ordered Separately) Note:Please refer to Figure 8 for recessed and concealed installation. Bulletin 074 Reliable Page 3 of 9 January 2023 www.reliablesprinkler.com r 7 Model F1FR56 Horizontal Sidewall Sprinkler SIN RA1435 Technical Specifications Recessed Escutcheonsg4 Style: Model F1 (cULus) Horizontal Sidewall Model F2(cULus,FM) Recessed Horizontal Sidewall Model FP(cULus) Threads:1/2"NPT or ISO 7-R1/2 Nominal K-Factor:5.6(80 metric) Guards&Shields(New Frames)(3) Max.Working Pressure: F-4 Guard(FM) 175 psi(12 bar) F-7 Guard(cULus) 250 psi(17 bar)(cULus only) Guards&Shields(Legacy Frames)(3) Material Specifications C1 Guard(FM) Thermal Sensor:3 mm Glass Bulb D1 Guard(cULus) Sprinkler Frame:Brass Alloy Sprinkler Wrenches Cap:Bronze Alloy Model W2(non-recessed) Sealing Washer:Nickel with PTFE Model W4(recessed) Load Screw:Copper Alloy Model J(New frame with guard installed) t 4,1 1, ` ji Deflector:Brass Alloy Model JD(Legacy frame with guard installed) Sprinkler Finishes (See Table B) Listings and Approvals Sensitivity cULus Listed(4) Quick response FM Approved(5) Temperature Ratings 47) 135°F(57°C) 155°F(68°C) 175°F(79°C) 200°F(93°C) 286°F(141°C) Notes: 1. 286°F(141°C)temperature rated sprinkler not listed for recessed use. 2. FM approved recessed installation when used with Model F2 escutcheon ONLY. 3. Not suitable for recessed horizontal sidewall installations. 4. cULus Listed for Light and Ordinary Hazard when installed exposed or surface mounted. Listed for Light Hazard ONLY when installed recessed. 5. FM Approved for Light Hazard ONLY. Model F1FR56 Horizontal Sidewall Sprinkler Components and Dimensions Figure 3 1 1/8"[28mm] Deflector Load Screw IIIII��III Frame Ifr„MI�I Glass Bulb 2 3/4"[70mm] (3 mm) F1FR_HALF_HSW r_ 1 Wrench Flat Cap/Seal Assembly —== Threads Note: Please refer to Figure 9 for recessed installation. Bulletin 074 Page 4 of 9 January 2023 Reliable www.reliablesprinkler.com Model Fl FR56 Vertical Sidewall Sprinkler SIN RA1485 Technical Specifications Guards&Shields(New Frames) Style: F-2 Guard(FM) Upright Vertical Sidewall Pendent Vertical Sidewall Guards&Shields(Legacy Frames) Threads: 1/2"NPT or ISO 7-R1/2 C1 Guard(FM) Nominal K-Factor:5.6(80 metric) Sprinkler Wrenches Max.Working Pressure: 175 psi(12 bar) Model W2 Model J(New frame with guard installed) Material Specifications Model JD(Legacy frame with guard Thermal Sensor:3 mm Glass Bulb installed) Sprinkler Frame:Brass Alloy Cap:Bronze Alloy „) Sealing Washer:Nickel with PTFEc Listings and Approvals Load Screw:Copper Alloy M F A Listed FM Approved Deflector:Brass Alloy LPCB(2) UKCA:0832-UKCA-CPR-S5045 Sprinkler Finishes (See Table B) Sensitivity — Quick response Temperature Ratings 135°F(57°C) 155°F(68°C) 175°F(79°C) 200°F(93°C) 286°F(141°C) Notes: 1. Listed and approved for Light Hazard ONLY. 2. LPCB approved for use in pendent position ONLY. Model F1 FR56 Vertical Sprinkler Components and Dimensions Figure 4 Deflector Load Screw ► 1 1/2" [38mm] Frame 111 Glass Bulb �v (3 mm) F1FR_HALF_VSW 2 1/4" [57mm] • RA CO RAACO Wrench Flat - --- Cap/Seal Assembly =— Threads Bulletin 074 Reliably Page 5 of 9 January 2023 www.reliablesprinkler.com r 1 Recessed and Concealed Installation:Pendent Sprinklers Figure 5 2-1/4" 2-1/4" (57 mm)Dia. (57 mm)Dia. Hole in Ceiling Hole in Ceiling 1-15/16" 1-15/16" (49 mm)Dia. Reducing (49 mm)Dia. Reducing Fitting Fitting 1.4 Face of Fitting Face of Fitting to Face of Ceiling to Face of Ceiling a mm)at Max. 7/8"(22 mm)at M .Recess pi Max.Recess 3/8"(10 mm)at 3/8"(10 mm)at . Min.Recess Min.Recess r � 1_ - - •• Am.. ,. .,.: 1-3/4" 1-3/4" (44 mm) 1" (44 mm) 1-1/4" I n (25 mm) ( IIPI (32 mm) Minimum Maximum Minimum Maximum Recess 2-7/8"(72 mm)Dia. - Recess Recess -2-7/8"(72 mm)Dia.- Recess Models F1&F1FR Pendent Sprinkler Models F1&F1FR Pendent Sprinkler with Model F1 Recessed Escutcheon with Model F2 Recessed Escutcheon 3/4"(19mm)Nominal Adjustment 1/2"(13mm)Nominal Adjustment Fi REC_PEND CCP 2-1/2" 2-1/2" (64 mm)Dia. (64 mm)Dia. Hole in Ceiling Hole in Ceiling 2-5/16" 2-5/16" (59 mm)Dia. Reducing (59 mm)Dia. Reducing Fitting Fitting Illi Face of Fitting Face of Fitting to Face of Ceiling to Face of Ceiling Vented Cup 1-1/2"(38 mm)at Vented Cup 1-1/2"(38 mm)at ill Max.Recess Max.Recess 1"(25 mm)at 1"(25 mm)at m= Min.Recess - ��__ Min.Recess , I*41.' =I' liEll ' 1- a elm ,... 1. (25 mm) (Pljuipr 1/2" (25 mm) ‘111Wir 1/2" .----------., (12 mm) (12 mm) Minimum t Minimum Recess 3-3/16"(78 mm)Dia. Recess Maximum Maximum Recess 3-5/16"(84 mm)Dia. Recess Models F1&F1FR Pendent Sprinkler with Model FP Recessed Escutcheon 1/2"(13mm)Nominal Adjustment Model F1FR56 CCP Conical Concealed Sprinkler 1/2"(13mm)Nominal Adjustment Note:Model FP recessed assemblies may not be used where the (Nominal Cover Plate Projection is 1"(25 mm)) pressure in the space above the ceiling is positive with respect to the protected area.Ensure that the openings in the Model FP cup Note:Model CCP concealed assemblies may not be used where are unobstructed following installation. the pressure in the space above the ceiling is positive with respect to the protected area. Ensure that the openings in the Model CCP cup are unobstructed following installation. .:' :;r1f#:*;'..' vOrix-'''''':::11110k.., #1111*.k., F1 Escutcheon FP Escutcheon CCP Cover Plate (F2 Similar) Bulletin 074 ReliablEj Page 6 of 9 January 2023 www.reliablesprinkler.com i Recessed Installation:Horizontal Sidewall Sprinklers Figure 6 1/2"(12 mm) Reducing +/-3/8"(10 mm) — 1-3/8"(35 mm)Maximum Recess Fitting Face of fitting to face of wall N II 4"-12" , (102mm-305mm) j ' ✓ Deflector to ceiling (571mm) 1-15/16" '' \ 7 Dia. (49 mm) = I (73 mm) Dia. Dia. Hole —9/16"[14mm] F1 Recessed escutcheon 3/4"(19 mm)Adjustment 2 1/8"(54 mm)Minimum Recess Model F1FR Horizontal Sidewall Sprinkler with Model F1 Recessed Escutcheon F1FR REC_HSW 3/4"(19mm)Nominal Adjustment 3/8"(16 mm) "1/4/- 6 mm Reducing + ( ) ,,,,. 1-5/8"(42 mm)Maximum Recess Fitting Face of fitting to face of wall t 4"-12" (102 mm-305 mm) —I—II 1 Deflector to ceiling 2-1/4" I ( ✓ 2-7/8" (57 mm) 1-15/16" _ I (73 mm) Dia (49 mm) Hole DIA. I I Dia. —9/16"[14mm] F2 Recessed escutcheon 1/2"(13 mm)Adjustment 2-1/8"(54 mm)Minimum Recess Model F1FR Horizontal Sidewall Sprinkler with Model F2 Recessed Escutcheon 1/2"(13mm)Nominal Adjustment 1-1/4"(32 mm) Reducing +/- 1/4"(6 mm) 7/8"(22 mm)Maximum Recess Fitting Face of fitting to face of wall t JI 4„-12" �I �7 (102 mm-305 mm) ✓ Deflector to ceiling 2-5/8" 2-5/16" II C I\I ) I, 3-1/4" (67 mm) (58 mm) (83 mm) Dia Dia. Dia. Hole. —9/16"[14mm]1 . r Vented Cup 1-3/8"(35 mm)Minimum Recess Model F1FR Horizontal Sidewall Sprinkler with Model FP Recessed Escutcheon 1/2"(13mm)Nominal Adjustment Note:Model FP recessed assemblies may not be used where the pressure in the space behind the sprinkler is positive with respect to the space in the protected area. Ensure that the openings in the Model FP cup are unobstructed following installation. Bulletin 074 Page 7 of 9 January 2023 Reliable www.reliablesprinkler.com r 1 Wrenches Model W2(upright, pendent) Model J (New frame with guard installed) Model JD(Legacy frame with guard installed,similar but with zinc finish) Model W4 (recessed,concealed pendent) Finishes') y{ y� /y�� s «yR�j p �1p"y�� Table B ..l,s— n l�Y litlisheS '. ' ? 6 s�eec/ ication�shes e �yg; ,p �y •J �i[fk w f s 3 h IJ , 1'y a FT'-' f cover h F I7 F2 and Sprinkler escutchez�»s. } tiler ct rrat� �? ?lste+�). .,. �ti# h POI)s �. Bronze Brass Chrome Electroless Nickel PTFE3>(4) Bright Brass Bright Brass Chrome Chrome White Paint Bright Brass(5) Satin Chrome Satin Chrome White Polyestero> White Polyester Satin Chrome Custom Color Polyester Custom Color Paint Custom Color Polyestert3) Notes: 1. Paint olr any other coating applied over the factory finish will void all approvals and warranties. 2. Model FP escutcheons and Model CCP sprinklers utilize a galvanized steel cup with a finished trim ring or cover plate. 3. cULus Listed as corrosion resistant. 4. FM Approved as corrosion resistant. 5. For 200°F(93°C)maximum temperature rated sprinklers only. Installation Maintenance Model F1 FR Series sprinklers must be installed in accordance with Reliable Model F1 FR series sprinklers should be inspected and NFPA13 and the requirements of all applicable authorities having the sprinkler system maintained in accordance with NFPA 25,as jurisdiction. Model F1 FR Series sprinklers must be installed with well as the requirements of any Authorities Having Jurisdiction. the Reliable sprinkler installation wrench identified in this Bulletin. Prior to installation,sprinklers should remain in the original Any other wrench may damage the sprinkler. The Models W2 and cartons and packaging until used.This will minimize the potential W4 wrenches have two sets of jaws. Use the smallest set of jaws for damage to sprinklers that could cause improper operation or that fit on the wrench flats of the sprinkler. A leak tight sprinkler non-operation. joint can be obtained with a torque of 8 to 18 lb-ft(11 to 24 N•m). Do not tighten sprinklers over the maximum recommended Do not clean sprinklers with soap and water, ammonia liquid or installation torque. Exceeding the maximum recommended any other cleaning fluids. Remove dust by gentle vacuuming installation torque may cause leakage or impairment of the without touching the sprinkler. sprinkler. Replace any sprinkler which has been painted(other than factory applied).A stock of spare sprinklers should be maintained to Glass bulb sprinklers have orange bulb protectors or protective allow quick replacement of damaged or operated snklers. caps to minimize bulb damage during shipping, handling and Failure to properly maintain sprinklers may result ipri n inadvertent installation. Reliable sprinkler installation wrenches are designed operation or non-operation during a fire event. to install sprinklers with bulb protectors in place. Remove the bulb protector at the time when the sprinkler system is placed in service for fire protection. Removal of the bulb protector before this time may leave the bulb vulnerable to damage. Remove bulb protectors by undoing the clasp by hand. Do not use tools to remove bulb protectors. Bulletin 074 Page 8 of 9 January 2023 e■■ ��ab�C www.reliablesprinkler.com Guarantee For the guarantee,terms, and conditions,visit www. reliablesprinkler.com. Ordering Information Specify the following when ordering: Model • F1FR56 Deflector/Orientation • Upright • Intermediate Upright • Pendent • CCP Concealed Pendent • Horizontal Sidewall • Vertical Sidewall Temperature Rating • See sprinkler technical specifications Sprinkler Finish • See Table B Recessed Escutcheono)(2) • F1 • F2 • FP Escutcheon Finish • See Table B CCP Cover Plate Temperature Rating • 135°F(57°C) [For use with 135°F(57°C) and 155°F(68°C)sprinklers.] • 165°F(74°C) [For use with 175°F(79°C) and 200°F(93°C)sprinklers.] CCP Cover Plate Finish • See Table B Sprinkler Wrench • Model W2 • Model W4(recessed,concealed) • Model J (New frame with guard installed) • Model JD(Legacy frame with guard installed) Notes: 1.286°F(141°C)sprinklers are not listed to be used recessed or concealed. N 2. For FM, recessed sprinklers must use the Model F2 escutcheon. rn rn rn rn rn z �t Bulletin 074 ReliablC Page 9 of 9 January 2023 www.reliablesprinkler.com fi bh 1 L•am ' ,� l{ s: • w��a Pry •::::...''''--,- --" ''''''. .:.._ .A..:{... i , ,„ , . . .,... . k w } t VALVES i ' Bulletin 621 March 2022 Reliabit Model CR Commercial Riser 1-1/2"through 8"(40-200 mm)Sizes cULus Listed, FM Approved Features • Cast stainless steel body for 1-1/2"models and 2"threaded .,. model • Schedule 10 welded body for 2"-8" grooved versions a,° ,," 1 • Optional schedule 40 manifold for 2" -4" sizes •` • Approved for vertical or horizontal installation ..' 0 Product Description The Reliable Model CR Commercial Riser arrives factory assembled with water flow switch, pressure gauge, and main drain for a cost-effective system riser or floor control assembly. The Model CR is cULus listed(VEOY.EX5980)and FM approved as a unit.The main drain is available with a ball valve or Reliable 3"(80mm)welded Commercial Riser Test and Drain valve,which is available with a wide selection of w/175psi Pressure Relief Kit and Test&Drain Valve(K5.6) test orifice K-factor choices.An optional pressure relief valve kit, available in 175, 185,210,260,and 310 psi(12, 13, 14, 18,and 21 bar)rating, is also available. Model CR Commercial Riser Table A '„'t ct for Pressure r End-# -Ends Optional Test Valve Size End Connections Material Drain Size'r. P . . . Rating Take Out w , v. Threaded Cast Stainless 8-1/4" 1" 25mm (NPT or BSPT) (210mm) ( ) 1-1/2" (40mm) Grooved 250 psi) Cast Stainless (241mm)/ 1" (25mm) 2.8(40) (17.2 bar Threaded 8-1/4" 4.2(60) 2"(50mm) (NPT or BSPT) Cast Stainless (210mm) 1"(25mm) 5.6(80) 2"(50mm) Grooved S10,S40 Steel 13 1"(25mm) (330mm) 2-1/2" (65mm) Grooved S10, S40 Steel 13" 1-1/4" 2.8(40) (330mm) (32mm) 4.2(60) ' 5.6(80) 3"(80mm) Grooved S10, S40 Steel 13" 1-1/4" 8.0(115) 300 psi (330mm) (32mm) 11.2(160) (20.7 bar) 4"(100mm) Grooved S10,S40 Steel 13 2"(50mm) 2.8(40) (330mm) 4.2(60) 6"(150mm) Grooved S10 Steel (330mm) 2" (50mm) 8.0(18�j 13" 11.2(160) 8"(200mm) Grooved S10 Steel (330mm) 2"(50mm) 16.8(240) *Note: K-factor must be equal to or less than the K-factor of the smallest K-factor installed on the sprinkler system. For sprinkler sys- tems where the smallest K-factor sprinkler on the system is greater than the largest available valve K-factor, use any valve K-factor that will provide a minimum flow of 10gpm (38 Ipm)as required to operate a UL Listed Waterflow Switch. www.reliablesprinkler.com Model CR Commercial Riser Threaded End Assemblies(1-1/2"[40mm]&2"[50mm]) Figure 1 B PRESSURE r GAUGE D Threaded End Basic Assembly w/T Pressure Relief Valve Table B / /, \ PRESSURE Mid, A B ,Ci E 3-WAY \ /I �y RELIEF in, x VALVE "!r'1I P. KIT ;pIR19SiG11 LE— I) 1-1/2 1 2 1 0 1/2 3 5 1/2 8 1/4 8.3 1/8 A al 111 (40) 308 (267) (80) (140) (210) (3.8) E � � Threaded ( ) (TAKE OUT) 6 Ends i (See Fig.1) 2 12 1/8 10-3/4 3-1/4 5-3/4 8-1/4 9.1 u �y', (50) (308) (273) (83) (146) (210) (4.1) 1 2-1 BALL VALVE WATERFLOW_/ MANIFOLD C ] (DRAIN DETECTOR BODY CONNECTION) BASIC ASSEMBLY(2"[50MM]VERSION SHOWN) WITH OPTIONAL PRESSURE RELIEF KIT 621FGO1C B PRESSURE HANDLE IN TEST POSITION GAUGE Threaded End w/Test&Drain Valve and Pressure Relief Kits Table C 3-WAY t/VALVE v�1lll,l I �. § In , In hi �&Weight 'INI�I�•) o",w 4171=O'-IItI1-1 t'..2. -a 12- Y "fit �,_ m1-1/2 12- 14-1/4 3 5-1/2 8-1/4 8.3 A .. 01 e f 1, Threaded (40) 308 (362) (80) (140) (210) (3.8) E i!� � � \`eJI! I Ends ( ) (TAKE OUT) 1 Or tall (See Fig.1) 2 1/8 1412 3-1/4 5-3/4 8-1/4 9.1 71III/I Pt" ID TEST/DRAIN (50) (308) O (83) (146) (210) (4.1) VALVE i CONNECTION) :i�-i l� WATERFLOW DETECTOR J MANIFOLD c _ BODY BASIC ASSEMBLY (2"[50MM]VERSION SHOWN) WITH TEST AND DRAIN VALVE &OPTIONAL PRESSURE RELIEF KIT (TEST AND DRAIN SHOWN IN'TEST"POSITION) Bulletin 621 Reliable Page 2 of 5 March 2022 www.reliablesprinkler.com , Model CR Commercial Riser Grooved End Assemblies(2"[50mm]-8"[200mm]) Figure 2 Grooved End Basic Assembly w/ Pressure Relief Valve Table D B - PRESSURE4. 1 T GAUGE D (L.-� .' Ri N4 inn PRESSURE 7 `411_cmne j j in ' y z. ,..in KIT { RELIEF / liwP�sl, ,'=' n.{ ); A*�'Yi f, nnc ) „I 7,:' ' )., 1REDUCINGECING 1-1/2 13-1/2 10-1/2 3 5-1/2 9-1/2 8.3 ® TEE (40) (343) (267) (76) (140) (241) (3.8) .iigi■ill) I 2 15-1/4 14-1/2 5-1/4 6 13 10.7 A use ' E (50) (387) (368) (133) (152) (330) (4.9) (TAKEOUT) 2-1/2 15-1/4 15 6-3/4 6-1/4 13 12.9 L K ll (65) (387) (381) (171) (159) (330) (5.9) WATERFLOW ) C7 Grooved DETECTOR Ends 3 15-1/4 16-1/4 7 6-1/2 13 17.6 , (See Fig.2) (80) (387) (413) (178) (165) (330) (8.0) / BALL 4 15-1/4 19 8-1/4 7 13 21.3 BFDIFOLDJ DRAIN VALVE BODY (80) (387) (483) (210) (178) (330) (9.7) C CONNECTION 6 15-1/4 21-1/2 9-1/4 8 13 26.3 BASIC ASSEMBLY(3•(SUMM]VERSION SHOWN) (150) (387) (546) (235) (203) (330) (11.9) WITH OPTIONAL PRESSURE RELIEF KIT 8 15-1/4 23 10-1/4 9 13 31.0 (200) (387) (584) (260) (229) (330) (14.1) B HANDLE IN TEST POSITION - D Grooved End w/Test&Drain Valve and Pressure Relief Kits Table E ,Maf ik4d°: A Tir 8 ' D` E wag 51livi d Pipe Size in In , Lin In "".;,in 'lbs PRESSURE , = ^ ■I♦M m GAUGE .Ii�rI�N����U �f �� ., .. fri OO14- e1 'iy 1-1/2 13-1/2 11-1/2 3-1/2 5-3/4 9-1/2 8.3 A 3-WAY •I (40) (343) (292) (89) (146) (241) (3.8) _ . E �' (TAKEOUT) � �_,: ,,� 2 15-1/4 16 5-1/4 6 13 10.7 WATERFLOW '`�1 "TEST AND DRAIN (50) (387) (406) (133) (152) (330) (4.9) DETECTOR r t VALVE(DRAIN 2-1/2 15-1/4 16-12 6-3/4 6-1/4 13 12.9 �!� \. CONNECTION) =mu (65) (387) (419) (171) (159) (330) (5.9) MANIFOLD Grooved 3 15-1/4 17-1/4 7 6-1/2 13 17.6 BODY c _ (see Fig.2) (80) (387) (438) (178) (165) (330) (8.0) BASIC ASSEMBLY(4• 00MM]VERSION SHOWN) 4 15-1/4 20-1/2 8-1/4 7 13 21.3 ]7 WITH TEST AND DRAIN VALVE (80) (387) (521) (210) (178) (330) (9.7) &OPTIONAL PRESSURE RELIEF KIT (TEST AND DRAM SHOWN IN TEST'POSIUON) 6 15-1/4 23 9-1/4 8 13 26.3 (150) (387) (584) (235) (203) (330) (11.9) 8 15-1/4 24-1/2 10-1/4 9 13 31.0 Notes: (200) (387) (699) (260) (229) (330) (14.1) 1. 1-1/2"grooved version will be cast in stainless steel. 2. 1-1/2"and 2"models will have threaded test and drain valve. Bulletin 621 eliable Page 3 of 5 March 2022 www.reliablesprinkler.com Installation Guarantee The Model CR Commercial Riser shall be installed in accordance For Reliable Automatic Sprinkler,Co., Inc.guarantee,terms, and with NFPA 13,"Standard for the Installation of Sprinkler Systems," conditions,visit www.reliablesprinkler.com. as well as the requirements of any authorities having jurisdiction. When installed vertically,the direction of flow shall be up through Ordering Information the assembly.For horizontal installations,the water flow indicator must be located to the top and drain opening to the bottom. Failure Specify: to follow installation instructions may void the warranty and/or listing of the valve.Verify compatibility of the Model CR Commercial Riser 1. Reliable Model CR Commercial Riser materials with the water supply and the environment where the valve 2. Size will be installed prior to installation. 3. End Connections 4. (Optional)Schedule 40(2"through 4"grooved end only) Maintenance 5. Drain Option(Ball valve or Test and Drain valve) 6. Test orifice K-factor(if ordering Test and Drain valve) The owner is responsible for maintaining the fire protection system 7. (Optional) Pressure Relief Valve Kit in proper operating condition.Any system maintenance or testing that involves placing a system out of service may eliminate the fire Notes: protection that is provided by the fire protection system.Notify any 1. All Model CR Commercial Riser Assemblies come with a 300 required authorities having jurisdiction and implement appropriate psi(20.7 bar)UL Listed and FM Approved pressure gauge precautions prior to proceeding. for 175 psi (12.1 bar)applications. If the Model CR Com- The Reliable Model CR Commercial Riser shall periodically be given mercial Riser Assembly is to be installed in a higher pressure a thorough inspection and test. NFPA 25,"Inspection,Testing and application, please purchase a 600 psi(41.4 bar) (P/N Maintenance of Water Based Fire Protection Systems,"provides 98248005) pressure gauge.This gauge may or may not be minimum maintenance requirements.Replace any components UL Listed and/or FM Approved at the time of purchase. found to be corroded,damaged,worn or non-operable.Increase 2. Unless specified at the time of ordering, pressure relief kits the frequency of inspections when the valve is exposed to corrosive are installed at the factory. conditions or chemicals that could impact materials and/or operation of the assembly. Note:The water flow switch for the 1-1/2"and 2"cast stainless steel manifold uses a proprietary paddle. This paddle is only available for purchase from Reliable.When replacing water flow switch,order part number 96556923. Bulletin 621 pe 'a Page 4 of 5 March 2022 �7 ` www.reliablesprinkler.com e a Commercial Riser Ordering Information Part Number Figure 3 6AXXOCPYYZ e coons Drain VaIvve/K-Facfkpr 04= 1-1/2"BSPT Female SS 00= 1" Ball Valve 0= None 05= 1-1/2"Grooved SS 03= 1" RASCO T&D Valve K2.8 1 = 175 psi (12.1 bar) 07=2"BSPT Female SS 04= 1" RASCO T&D Valve K4.2 2= 185 psi(12.8 bar) 08= 1-1/2"NPT Female SS 05= 1" RASCO T&D Valve K5.6 3=210 psi (14.5 bar) 09=2" NPT Female SS 4=260 psi (17.9 bar) 10=2"Grooved SCH10 5=310 psi(21.4 bar) 11 =2"Grooved SCH40 12=2-1/2"Grooved SCH10 01 = 1-1/4" Ball Valve 13=2-1/2"Grooved SCH40 26= 1-1/4" RASCO T&D Valve K2.8 14=3"Grooved SCH10 06 = 1-1/4" RASCO T&D Valve K4.2 15=3"Grooved SCH40 07= 1-1/4" RASCO T&D Valve K5.6 08= 1-1/4" RASCO T&D Valve K8.0 09= 1-1/4" RASCO T&D Valve K11.2 16=4"Grooved SCH10 02=2"Ball Valve 17=4"Grooved SCH40 27=2"RASCO T&D Valve K2.8 18=6"Grooved SCH10 28=2" RASCO T&D Valve K4.2 19=8"Grooved SCH10 10=2" RASCO T&D Valve K5.6 11 =2"RASCO T&D Valve K8.0 12=2" RASCO T&D Valve K11.2 13=2" RASCO T&D Valve K16.8 Notes: 1. 1-1/2"and 2"manifolds have a 1"threaded drain outlet. 2. 2-1/2"and 3"manifolds have a 1-1/4"grooved outlet for Test&Drain valve or a 1-1/4"threaded outlet for ball valve drain. 3. 4",6",and 8"manifolds have a 2"grooved outlet for Test&Drain valve or 2"threaded outlet for ball valve drain C) a O a) C, C) Bulletin 621 Page 5 of 5 °' March 2022 Reliable www.reliablesprinkler.com a iti..;(k:ig:.,,,ItaiSiNior, • ,....s,e H . " xa ` m #r ,. tli I- ,. . ,.41,N. :1;4% :4,4 r / rt '+ ,,,,„,,,,„,.-.7." ' :Ii.tN'k' ri h-M k , ''' ',.: , , c- _,. .„.,,...\ a': PIPE & FITTINGS Schedule-I O/Schedule-40 - M-COAT ® Submittal Data Sheet > Fully Listed and FM Approved Sprinkler Pipe Sch-40-M-COAT Specifications NPS Nominal I.D. Wt. Wt.(H20 Filled) CRR When you specify Schedule-10/Schedule-40-M-COAT'sprinkler pipe from Allied Tube In;mm In;mm LbslFt;kg/rn Lbs/Ft;kg/m> - &Conduit,you get UL listed and FM approved products.Although these products do 1" 1.049 1.680 2.05 1 not require separate approvals,Schedule-10/Schedule-40-M-COAT gives you the extra 25 26.6 2.5 3.05 - quality assurance you demand.Our Sch-10(1-1/4"-8")pipe and Sch-40(1"-2-1/2") 11/4" 1.380 2.270 2.93 1 pipe have passed the same thorough lab testing as our other listed pipe products,and 32 35.1 4.36 4.36 - receive periodic mill inspections from both UL and FM agents to ensure consistent quality. 1'/2" 1.610 2.720 3.61 1 40 40.9 4.0 5.37 - > Galvanized Pipe Schedule-10/Schedule-40-M-COAT product can be 2" 2.067 3.650 5.13 1 "hot-dip" galvanized to meet FM requirements. 50 52.5 5.4 7.63 - 2' " 2.469 5.790 7.86 1 > Superior Coating Our advanced formula mill coating offers a clean,durable 65 62.7, 8.6 11.73 - surface that is also paintready for custom color applications without special preparation. Sch-10-M-COAT Specifications The internal surface of all black Fire Sprinkler pipe up to 4.5000" in diameter shall be NPS Nominal I.D. Wt. Wt.(H20 Filled) CRR coated with Allied Tube &Conduit Antibacterial Formula "M-COAT". In;mm In;mm Lbs/Ft;kg/m Lbs/Ft;kg/rn - 1'/4" 1.442 1.810 2.525 7.0955 > American Made Able to meet"Buy American" requirements,and is available 32 36.6 2.7 3.75 through distributors in the USA, Canada, Mexico and Latin America. 1Y2" 1.682 2.080 3.04 5.6570 40 42.7 3.1 4.52 > Specifications & Approvals Schedule-10-M-COAT pipe is in 2 2.157 2.640 4.22 4.5827 compliance with ASTM A135,Type E Grade A,and NFPA 13.Schedule-40-M-COAT 50 54.8, 3.9 6.28 - pipe is in compliance with ASTM A135/A795,Type E Grade A,and NFPA 13. 21h" 2.635 3.530 5.89 3.5196 - Both pipe products have a working pressure rating of 300 psi maximum and also meet 65 66.9 5.3 8.77 the stringent requirement for the followingtests:Welded Outlets, Hydrostatic Pressure, 7� 83.2 8 4.3306. 1 8 2.5550- 9 q Y 75 ;, 82.8, 6.4 11.$2 Side Wall Rupture,Vibration Test. 4" 4.260 5.610 11.78 1.6020 100 108.2 8.3 17.53 - 5" 5.295 7.77 17.33 1.4874 125 134.5 11.56 25.80 - 6" 6.357 9.290 23.03 1.0251 150 161.5 13.8 34.27 - 8" 8.249 16.490 40.15 1.8365 200 209.5 24.5 59.75 - F CL c® 41> APPROVED Project: Sprinkler Contractor: Date: Engineer: Specification Reference: System Type: Locations: Comments: ^® Customer Service (800) 882-5543 Fax: (800) 659-7730 www.alliedtube-sprinkler.com T �I I I�/� • 16100 S Lathrop Ave. • 11350 Norcom Rd. •2525 N 27th Ave. •600 Dean Sievers Place TUBE & CONDUIT® Harvey,IL 60426 Philadelphia,PA 19154 Phoenix,AZ 85009 Morrisville,PA 19067 A PART O,.,Glatkore • i Victaulic® FireLockTM Fittings 4tauiicr 10.03 1.0 PRODUCT DESCRIPTION Available Sizes • 11/4—8'/DN32— DN200 Maximum Working Pressure • Pressure ratings for Victaulic FireLockTM Fittings conform to the ratings of Victaulic FireLock EZTM Style 009N couplings (refer to publication 10.64 for more information). Application • FireLockTM fittings are designed for use exclusively with Victaulic couplings that have been Listed or Approved for Fire Protection Services. Use of other couplings or flange adapters may result in bolt pad interference. • Connects pipe, provides change in direction and adapts sizes or components Pipe Materials • Carbon steel 2.0 CERTIFICATION/LISTINGS can ® oLPCB Vd$ E UK LISTED CA EN 10311 BS EN 10311 CPR(EU) CPR(UK) No.305/2011 2019 No.465 3.0 SPECIFICATIONS- MATERIAL Fitting: Ductile iron conforming to ASTM A536, Grade 65-45-12. Fitting Coating: (specify choice) ❑ Orange coating. ❑ Red coating(standard for EMEA-I and Asia Pacific). ❑ Optional: Hot dipped galvanized. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION,MAINTENANCE OR SUPPORT. victaulic.com 10.03 1539 Rev P Updated 07/2022 ©2022 Victaulic Company.All rights reserved. 1 ✓Ctaulic victaulic.com 4.0 DIMENSIONS k-CtoE-1 C I "0 i to v� p CtoE p p ME E ii____, br ��� .1°r''�% =i= tE No.001 No.003 No.002 No.006 No.001 No.003 No.002 I No.006 90°Elbow 45°Elbow Straight Tee Cap Actual Approximate Approximate Approximate Approximate Nominal Outside Weight Weight Weight 1 Weight Size Diameter C to E Each C to E Each C to E Each i T Each inches inches inches lb inches lb inches lb 1 inches lb DN mm mm kg mm kg mm kg mm kg 11/2 1.900 - - - - - - 0.82 0.4 DN40 48.3 - - - - - - 21 0.2 2 2,375 2,75� 1.7 i2,00 1,8 2,75' 2,4 0.88" ' 0.6 DN50 60.3 70 :: 0.8 51 0.8 70 1.1 22 0.3 21 2.875 3.00 3.1 2.25 2.2 3.00 3.6 0.88 1.0 73.0 76 1.4 57 1.0 76 1.6 22 0.5 3.000 3.00 3.30 2,25} 2=4 3.00 3.0 DN65 76.1, 76 1,5 57 1.1 76 1,7 - 3 3.500 3.38 4.0 2.50 3.1 3.38 5.3 0.88 1.2 DN80 88.9 86 1.8 64 1.4 86 2.4 22 0.5 4.250 4.00 57 350 5.1 400, 75 108.0 102 2.6.. 76 2,3 102 34 4 4.500 4.00 6.7 3.00 5.6 4.00 8.7 1.00 2.4 DN100 114.3 102 3.0 76 2.5 102 3.9 25 1.1 5 5563 4.88 12,6 325 8.3 4.88 15.7 141.3 124 5.7 83; 3.8 124 . 7.1 25 1.9 5.500 4.88 12.4 3.25 8.2 4.88 15.4 - - DN125 139.7 124 5.6 82.6 3.7 124 6.9 6.250 550 12.6 3.50 9.2 5,50 17.9 - 158.8 140 5.7 89 4.2 140 8.0 - 6 6.625 5.50 18.3 3.50 11.7 5.50 22.7 1.00 5.9 DN 150 168.3 140 8.3 89 5.3 140 10.3 25 2.7 6.500 5.43 17.6... 3.50 11.4 5.50 22.0 165.1 140 7.9 89. 5,2 _ 140 9.9 8 8.625 6.81 25.5 4.25 20.4 6.94 38.7 1.13 12.7 DN200 219.1 173 11.6 108 9.3 176 17.6 29 5.8 8.515 6.81 : 23.1 . - - 6.94 33.6 - - 216.3 r 173 10.5 - 176 "`" 15.2 - . 10.03 1539 Rev P Updated 07/202 ©2022 Victaulic Company.All rights reserved. victaulic.com 2 ✓ataulic victaulic.com • 5.0 PERFORMANCE Flow Data Size 1 Frictional Resistance Equivalent of Straight Pipel No.002 Actual L Elbows Straight Tee Nominal Outside i No.001 No.003 Size Diameter ! 90°Elbow 45°Elbow Branch Run inches inches feet feet feet feet DN mm meters meters meters meters a DN32 42.4 - - - - 11/2 1.900 - - - - DN40 48.3 - - - - 2 2.375 2 Y 2.875 4.3 2.2 10.8 4.3 73.0 1.3 0.7 3.3 1.3 3.000 4.5 2.3 11.0 4.5 DN65 3 3.500 5.0 2.6 13.0 5.0 DN80 88.9 1.5 0.8 4.0 1.5 2.0 4 4.500 6.8 3.4 16.0 6.8 DN100 114.3 2.1 1.0 4.9 2.1 5 5.563" 8.5" 4.2 ..� 21.0 8.5 141:3' 2.6 1.3 ,," 6.4 2.6 5.500 8.3 4.1 20.6 8.3 DN125 139.7 2.5 1.3 6.3 2.5 _ 6 250 9.4 4.9 25.0 9.6 158.8 2.9 15. 7.6 2.9 6 6.625 10.0 5.0 25.0 10.0 DN150 168.3 3.0 1.5 7.6 3.0 6.500 9.8 4.9 24.5 9.8 -- 1 3.0 8 8.625 13.0 5.0 33.0 13.0 DN200 219.1 4.0 1.5 10.1 4.0 8515 13.0 33.0 13.0 215.3 4.0 _. 10.1 4.0 ' The flow data listed is based upon the pressure drop of Schedule 40 pipe. • • 10.03 1539 Rev P Updated 07/202 ©2022 Victaulic Company.All rights reserved. victaulic.com 3 ✓atauliC Y � victaulic.com 6.0 NOTIFICATIONS General Notes NOTE: When assembling FireLock EZT" couplings onto end caps,take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZTM Style 009N/009H couplings, use FireLock'' No. 006 end caps containing the "EZ" marking on the inside face or No. 60 end caps containing the "QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009/009V/009H/009N couplings. 7.0 REFERENCE MATERIALS 10.64_Victaulic®FircLock°^"RigidCocling Style 009N 10.02:Victaulic®FireLockT"^Rigid Coupling SLyje 005H with Vic-Plus'''Gasket System 29.01:Victaulic®Terms and Conditions of Sale • • User Responsibility for Product Selection and Suitability Note Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications.All products Victaulic products for a particular end-use application,in accordance with industry to be installed in accordance with current Victaulic installation/assembly instructions. standards and project specifications,and the applicable building codes and related Victaulic reserves the right to change product specifications,designs and standard regulations as well as Victaulic performance,maintenance,safety,and warning equipment without notice and without incurring obligations. instructions.Nothing in this or any other document,nor any verbal recommendation, Installation advice,or opinion from any Victaulic employee,shall be deemed to alter,vary,supersede, Reference should always be made to the Victaulic installation handbook or installation or waive any provision of Victaulic Company's standard conditions of sale,installation instructions of the product you are installing.Handbooks are included with each shipment guide,or this disclaimer. of Victaulic products,providing complete installation and assembly data,and are available Intellectual Property Rights in PDF format on our website at www.victaulic.com. No statement contained herein concerning a possible or suggested use of any material, Warranty product,service,or design is intended,or should be constructed,to grant any license Refer to the Warranty section of the current Price List or contact Victaulic for details. under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design,or as a recommendation for the use of such Trademarks material,product,service,or design in the infringement of any patent or other intellectual Victaulic and all other Victaulic marks are the trademarks or registered trademarks of property right.The terms"Patented"or"Patent Pending"refer to design or utility patents Victaulic Company,and/or its affiliated entities,in the U.S.and/or other countries. or patent applications for articles and/or methods of use in the United States and/or other countries. • •10.03 1539 Rev P Updated 07/202 ©2022 Victaulic Company.All rights reserved. victaulic.com 4 ✓ataulic • Victaulic® Grooved End Fittings ✓ctaulid 07.01 • No.20 Tee No. 10 Elbow 1.0 PRODUCT DESCRIPTION Available Sizes • 3/4—24'/DN20— DN600 Pipe Material • Carbon steel Maximum Working Pressure • Pressure ratings for Victaulic standard fittings conform to the ratings of Victaulic Style 77 couplings (refer to publication 06.04 for more information). Application • Connects pipe, provides change in direction and adapts sizes or components • Supplied with Victaulic Original Groove System (OGS) grooves • Exclusively for use with Victaulic couplings, valves, accessories and pipe which feature ends formed with the Victaulic OGS groove profile NOTES • For 14"/DN350 and larger roll grooved systems for carbon steel pipe,Victaulic offers fittings for the Advanced Groove System(AGS).Refer to publication 20.05 for more information. • These fittings are not intended for use with Victaulic plain end couplings.Intended for use only in grooved piping systems.When connecting wafer or lug type butterfly valves directly to Victaulic fittings using Style 741 or Style 743 flange adapters,be sure to check disc clearance dimensions with I.D.dimension of fitting. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION,MAINTENANCE OR SUPPORT. victaulic.com 07.01 1449 Rev AJ Updated 05/2023 ©2023 Victaulic Company.All rights reserved. 1 ✓ctaulic • victaulic.com • 2.0 CERTIFICATION/LISTINGS cOus ® PCB.,: vdS C E UK CA usreo pvrxau® v EN 10311 BS EN 10311 CPR(EU) CPR(UK) No.305/2011 2019 No.465 NOTES • When supplied as"hot dip galvanized"the following fittings are UL Classified in accordance with ANSI/NSF 61 and for use on cold+86"F/+30"C potable water service and ANSI/NSF 372:No.10 90"Elbow,No.11 45"Elbow,No.12 221/2"Elbow,No.13 11/a"Elbow,No.100 90"Long Radius Elbow,No.110 45"Long Radius Elbow,No.20 Tee,No.25 Tee with Grooved Branch,No.30 45"Lateral,No.60 Cap,No.50 Concentric Reducers,No.51 Eccentric Reducers. • The following Victaulic fittings are VdS approved:No.10 90"Elbow,No.11 45"Elbow,No.20 Tee and No.60 Cap. • The following Victaulic fittings are LPCB approved:No.10 90"Elbow,No.11 45"Elbow,No.12 22 1/2 Elbow,No.13 11 IA"Elbow,No.30 45"Lateral,No.30-R Reducing Lateral,No.100 Long Radius Elbow,No.110 Long Radius Elbow,No.20 Tee,No.35 Cross,No.60 Cap,No.25 Reducing Tee,No.33 True Wye,No.50 Concentric Reducer,No.51 Eccentric Reducer and No.29M Tee with Threaded Branch. • The following Victaulic fittings are FM approved:No.10 90"Elbow,No.11 45"Elbow,No.12 221 Elbow,No.13 11 1/"Elbow,No.30 45"Lateral,No.100 Long Radius Elbow,No.20 Tee,No.35 Cross,No.60 Cap,No.25 Reducing Tee and No.50 Concentric Reducer. • Download publication 10.01 for Fire Protection Certifications/Listings Reference Guide to view which sizes of the fittings listed above have active fire protection approvals. 3.0 SPECIFICATIONS- MATERIAL Fitting: (specify choice) ❑ Standard: Ductile iron conforming to ASTM A536, Grade 65-45-12. ❑ Optional: Segmentally welded carbon steel, standard wall, conforming to ASTM A53, Type E or S, Gr. B Nipples: (specify choice) ❑ 3/4-6"/DN20-DN150: Carbon steel, Schedule 40, conforming to ASTM A53, Type E or S, Gr. B ❑ 8- 12"/DN200- DN300: Carbon steel, standard wall, conforming to ASTM A53, Type E or S, Gr. B Flanged Adapter Nipples: (specify choice) ❑ Class 125 Flange: Cast iron conforming to ANSI B16.1 ❑ Class 150 Flange: Carbon steel conforming to ANSI B16.5, raised or flat face ❑ C• lass 300 Flange: Carbon steel conforming to ANSI B16.5, raised or flat face Fitting Coating: (specify choice) ❑ Standard: Orange enamel ❑ O• ptional: Hot dip galvanized and others. Some fittings supplied electroplated as standard-see product specifications Flanged Adapter Nipple Coating: (specify choice) ❑ Standard: None (Unfinished) 0 Optional: Orange enamel, hot dip galvanized and others • 07.01 1449 Rev AJ Updated 05/2023 ®2023 Victaulic Company.All rights reserved. victaulic.com 2 ✓ctaulic victaulic.com 4.0 DIMENSIONS Elbows No. 1090° Elbow .-ctoE+l No. 11 45° Elbowcf illill ,\ c to E to E L. - ------_--- No.10 _.._�.._.__ No.11---- - Size 90°Elbow 45°Elbow Actual - Approx. Approx. Outside Weight Weight Nominal Diameter C to E (Each) C to E (Each) inches inches inches lb inches lb DN mm mm kg mm kg 34 ,: 1.050 = 2.25 0.5 1.50 ' .0.5 DN24,;:. 26.9 57 0.2 .38 0.2 1 1.315 2.25 0.6 1.75 0.5 DN25 33.7 57 0.2 44 0.2 1''A 1.660 ,2.75 0.8 1.75 06 0N32 42,4 70 0,4 44 0.3 1 y2 1.900 2.75 1.0 1.75 0.8 _ DN40 _ 48.3... 70 0.5 r, 44 0.4 2 2.375 3,25 18 .. 2.00 1.3 DN50 60.3 83 08 51 = 0.6 2 Y2 2.875 3.75 3.0 2.25 2.1 73.0 95 1.3 57 1.0 _^ 3.000 3.75 3.1 2.25 2.3 DN65 = 76.1 95 1A 57 1.0 3 3.500 4.25 4.5 2.50 3.0 DN80 88.9 108 2.0 64 1.3 31 4.000 4.50 5.6` 2.75 4.0 DN90 101.6 114 ',- 25 70 1.8 4.250 5.00 6.2 3.00 4.6 108.0 127 2.8 76 2.1 4 4.500 5.00 6.8 3.00 5.2 DN100 114.3 127 3.1 _ 76 2A 4 V2 5.000 5.00 8.6 3.13 5.9 127.0 127 3.9 79 2.7 5.250 5.50 10.3,.-- 3.25 66 133.0 140. 4.7 83 - 3.0 5.500 5.50 9.9 3.25 7.2 DN125 139.7 140 4.5 83 3.2 5 5.563 5.50 10.1 3.25 7.4 14T3 140 46 - 83 3.4 6.000 6.50(sw) 13.3 3.50(sw) 9.5 152.4 - 165 6.0 89 4.3 6.250 6.50 13.0 3.25 9.5 159.0 165 5.9 83 4.3 6.500 6.50 15.5 3.50 9.7 165.1 165 7.0 89 4.4 6 6625 6.50 153 3.50 10,2 DN150 168..3 165 6.9 89 4.6 200A 216.3 7.75 34.7 4.25 14.4 197 15.7 108 6.5 ' For 14'/DN350 and larger roll grooved systems for carbon steel pipe,Victaulic offers fittings for the Advanced Groove System(AGS).Refer to publication20.05 for more information.For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. (sw)=Carbon Steel Segmentally Welded NOTE • All fittings are ductile iron unless otherwise noted with an(sw). • , 07.01 1449 Rev AJ Updated 05/2023 ©2023 Victaulic Company.All rights reserved. victaulic.com 3 ✓1taulicr • victaulic.com • •4.0 DIMENSIONS (CONTINUED) Elbows No. 1090° Elbow r-ctoE1 No. 11 45° Elbow ctoE I � � - '_ 'C to E L. No.10 No.11 Size 90°Elbow 45°Elbow Actual I Approx. Approx. Outside Weight Weight Nominal Diameter C to E (Each) C to E I (Each) inches inches inches lb inches lb DN mm mm kg mm kg 8. 8.625" 7.75 275 4.25 18:6? DN200 219.1 197 12.5 108 SA" 250A 267.4 9.00 67.8 4.75 28.1 229 30.7 121 12.7 10 10.750 9.00 T 50.0_. - 4.75 37.5 DN2S0 273.0 229 , 22.7 121 <' .' :,'17,0 300A 318.5 10.00 73.5 5.25 41.3 __ 254 33.3 133 18.7 12 12.750 10.00 79.3 5.25 '" 45.0 DN300 , 323.9 254'" .. 360 133 20.4 "";ry 141 14.000 14.00 146.0 5.80 78.0 DN350 355.6 356 66.2 147 35.4 14.843,, 14,88 ie 168Q 6.15 82.0 277".0 378 76.3 156 37.2 161 16.000 16.00 190.0 6.63 88.2 DN400 406.4 406 86.2 168 40.0 16,772 16.75; 216,0 .::;"6.95 98.1 426.0 425 98A,." 18' 18.000 18.00 241.0 7.46 123.0 DN450 457.2 457 109.3 189 55.8 18.898 18:90 291.0 7.83 123.2 480.0 . 480 132.0 199 53.9 201 20.000 20.00 296.0 8.28 151.0 DN500 508.0 508 134.3 210 68.5 20.866 20,88 355.0 8.64. 179.0 530.0,, 530 161.0 .' 219 81.2 22 22.000 25.00 386.0 12.11 210.0 DN550 558.8 635 175.1 308 95.3 24' 24.000 24.00 475.0 ", 9,94 240.0 DN600 , 609,E 610 " '.: 215.5 :- , 252 108.9 24.803 24.75 545.0 10.27 275.4 630.0 629 247.2 261 124.9 14-60 For AGS fitting information,see publication 20.05 DN350-DN1500 _AGS ' For 14'/DN350 and larger roll grooved systems for carbon steel pipe,Victaulic offers fittings for the Advanced Groove System(AGS).Refer to publication 20.05 for more information.For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. (sw)=Carbon Steel Segmentally Welded NOTE • All fittings are ductile iron unless otherwise noted with an(sw). • •07.01 1449 Rev AJ Updated 05/2023 ©2023 Victaulic Company.All rights reserved. victaulic.com 4 ✓ctaulhc• victaulic.com 4.0 DIMENSIONS (CONTINUED) Elbows No. 12 221/2° Elbow No. 13 111/4° Elbow to-4.c ` I t 11- E CtoE ail n 0 No.12 No. 12G(GSNK) No. 13 Size 22 W Elbow 221h°Elbow 111/4°Elbow Actual Outside Approx.Weight Approx.Weight Approx.Weight Nominal Diameter C to E (Each) E to E (Each) C to E (Each) inches inches inches lb inches lb inches lb DN mm mm kg mm kg mm kg ' 1050 ' 1.63(sw) 0.4 ' 138(Sw) 0.4 0.2 1 1.315 1.63(sw) 0.5 3.25 0.6 1.38(sw) 0.4 DN25 33.7 41 0.2 _ 83 0.3 35 0.2 11A .. 1,660 1,75 0:8 NA NA 1,38 "" 40.6 DN32 42.4 44: 0.4 11 1.900 1.75 1.0 NA NA 1.38 0.6 DN40 48.3 44 0.4 35 0.3 2 2.375 ", 1.88 . 1.2 " 3.75r: 14 138 1,0 DN50_ 60.3 48'- " .. 21 2.875 2.00(sw) 2.4 4.00 2.0 1.50 1.6 73.0 51 1.1 102 0.9 38 0'7 3.000 2 25 2.5 DN65 76.1 57" 1.1 38 '` 0.8. 3 3.500 2.25(sw) 3.1 4.50 3.1 1.50 2.0 DN80 88.9 57 1.4 114 1.4 38 0.9 3 Y2 ' 4.000 2.50(sw) 4.0 NA NA 1.75 0sw) 2.8 " ONO:,. . ' 101.6. : 64 1.8 4.250 2.88(sw) 1.75(sw) 108.0 73 + NA NA 44 + 4" ' 4.500 2,88 4.8 5,25 ; 4.8 1,75 3.3 DN 100;. 114 3 :;.. 73. 2.2 133" 22 44 1.5 41/2 5.000 2.88(sw) + NA NA 1.88(sw) i + 127.0 73 _ 48 ' S,250 2,88(sw7 + NA NA 2.00(sw) +" 5.500 2.88 6.3 NA NA 2.00 4.6 DN12S 139.7 73 2.9 _ 51 2.1 5 5 563 2,88(sw);; : 7,8 2:00(sw) . 5.0 s'::141.3 .. '.. . 73 - 3.5 NA 6.000 3.13(sw) + NA NA 2.00(sw) + 152.4 79 51 . 6.250 "; 3.13(sw) + NA NA 2.00(sw) 159,0,',.". :: . 79 6.500 3.13 10.4 2.00 7.1 165.1 79 4.7 NA NA 51 3.2 12.2 6.25 12.2 2.00 6,4 DN150 1683 79 5.5 159 5.5 51 2.9 i For 14"/DN350 and larger roll grooved systems for carbon steel pipe,Victaulic offers fittings for the Advanced Groove System(AGS).Refer to publication 20.05 for more information.For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. (sw)=Carbon Steel Segmentally Welded NA=Not Available "+"=Contact Victaulic for details NOTE • All fittings are ductile iron unless otherwise noted with an(sw). 07.01 1449 Rev AJ Updated 05/2023 CO 2023 Victaulic Company.All rights reserved. victaulic.com 5 ✓otauli victaulic.com • • 4.0 DIMENSIONS (CONTINUED) Elbows No. 12 221/2° Elbow No. 13 111/4° Elbow ctoE` t I- EtoE CtoE ni No.12 No. 12G(GSNK) No. 13 Size 221/2°Elbow 22 W Elbow 11W Elbow Actual -----^ I - Outside Approx.Weight Approx.Weight I Approx.Weight Nominal Diameter C to E (Each) E to E (Each) C to E (Each) inches inches inches lb inches lb inches lb DN mm mm kg mm kg mm kg 8 : .625 3.88(sw) 20.0 7.50 18.>1 ° f,. y 2 00 ..: 8.2 DN200 219.1 98 9.1 191 " .' 8.2. 51" 3.7 10 10.750 4.38 30.0 2.13 11.8 DN250 273.0 111 13.6 NA NA 54 5.3 12 12.750 4.88 40.0 2.25 29.3 DN300 323.9 124 18.1 NA NA" 57 :� 13.3 14' 14.000 5.00(sw) 46.0 3.50(sw) 32.0 DN350 355.6 127 20.9 NA NA 89 14.5 16' 16.000. 5.04(sw):° ." 58 0 NA NA 4.00(sw)" 42.8 DN400 406t4. 127 " 26.3 , >. :.._" _�._. 102 19.1 _ 18' 18.000 5.50(sw) �65.0 NA NA 4.50(sw) 53.0 DN450 457.2 140 29.5 114 24.0 20 20.000 ,6.00(sw) 78.6 NA NA 5.00(sw) -_ 65.0 . - v ., ))N500 '508.0 _ 152 35:7 _ :127 - " 29.5' 22 22.000 6.50(sw) 125.0 5.50(sw) 80.0 DN550 558.8 165 _ 56.7 NA NA 140 36.3 24' 24.000 7.00(sw) 140.0 6.00(sw) 94.5 ' 0N600 609.6 178 63.5 NA NA 152 42.9', 14-60 For AGS fitting information,see publication 20.05 DN350-DN 1500 A GS- 1 For 14"/DN350 and larger roll grooved systems for carbon steel pipe,Victaulic offers fittings for the Advanced Groove System(AGS).Refer to publication 2005 for more information.For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. (sw)=Carbon Steel Segmentally Welded NA=Not Available "+"=Contact Victaulic for details NOTE • All fittings are ductile iron unless otherwise noted with an(sw). • • 07.01 1449 Rev AJ Updated 05/2023 ©2023 Victaulic Company.All rights reserved. victaulic.com 6 ✓ctaulic victaulic.com • • 4.0 DIMENSIONS (CONTINUED) Elbows No. 100 90° Long Radius Elbow '-ct0 E---1 No. 110 45° Long Radius Elbow i II C to r\ Air No.100 No.110 90°11/D 45°1 Y2D Size Long Radius Elbow Long Radius Elbow Actual Outside Approx.Weight Approx.Weight Nominal Diameter C to E (Each) C to E (Each) inches inches inches lb inches lb DN mm mm kg mm kg DN2A 26:9 G4 0 2 44 0.2 1 1.315 2.88(s) 0.8 2.25(s) 0.6 DN25 33.7 73 0.4 57 ry 0.3 1114 1.660 3.25(s) 1.1 2.38(s) 0.9 -_` 11/2 1.900 3.63(s) 2.2 2.50(s) 1.1 DN40 48.3 92 1.0 64 0.5 2: ::'2.375 : ..438 2.6 2.75` - 1,9 21/2 2.875 5.13 3.4 3.13(s) 3.0 73.0 130 1.5 79 1.4 DN80 88.9 31/2 4.000 6.63(s) 8.7 3.63(s) 5.6 -� DN90 101.6 168 3.9 92 2.5 4 4.500 7.50 10.8 : 4.00 7.4 DN100. 1143 19i 4.9 102 3.4 5 5.563 9.25 18.0 4.25 14.8 141.3 235 8.2 108 -- - 6.7 .:6.500 °. 10,75: 25.8 5.50 15.8 '165.1 273: 11.7 .; 140 - 7.2 6 6.625 10.75 30.4 5.38 16.7 DN 150 168.3 273 13.8 137 7.6 DN200 � 219.1 : 362 31.1 10 10.750 15.00 81.6 6.25 40.1 DN250 273.0 381 37.0 159 18.2 s 12 12.750 18.00 138.0 7:5fl 69.6 0N300 323.9 457. ` . 62.6 141 14.000 21.00 222.7 8.75 112.4 DN350 355.6 533 101.0 222 51.0 161 16.1100 24.00 302.0 10.00 158.7 DN400 406.4 610 137.0 254 720 18' 18.000 27.00 421.8 11.25 224.9 DN450 457.2 686 191.3 286 102.0 201 20.000 30.00 498.2 12.50 246.9 DN500 508.0 762 ,; '226.0.' 318 112.0 22' 22.000 36.00(s) 400.0 16.50(s) 205.0 DNSSO 558.8 914 181.4 419 93.0 241 24Aflfl 36,00 765.0 15.00 370.4 ;.0N600 609.6 914 347,0 381 For AGS fitting information,see publication 20.05 14-60 DN350-DN1500 AGS~ 1 For 14"/DN350 and larger roll grooved systems for carbon steel pipe,Victaulic offers fittings for the Advanced Groove System(AGS).Refer to publication 20.05 for more information.For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. (s)=Carbon Steel NOTE • All fittings are ductile iron unless otherwise noted with an(s). • , 07.01 1449 Rev AJ Updated 05/2023 ©2023 Victaulic Company.All rights reserved. victaulic.com 7 jctsulie victaulic.com 4.1 DIMENSIONS No. 10-DR 90° Drain Elbow 1-C-E- C-E H 1"NPT Drain Tap G---1 B No. 10-DR T Size 90°Drain Elbow 1 Weight Actual Approx. Nominal Outside Diameter C to E OB G H Drain Tap NPT (Each) inches inches inches inches inches inches inches lb DN mm mm mm mm mm mm kg 2Y2 2.875 3.75 1.81 2.75 1,68 1 35' 73.0 95 46 70 43 25 1.6 3 3.500 4.25 1.81 2.75 2.13 1 4.8 0N80 88.9 108 46 70 54 _ 25 2.2 4 4.500 - 5.00 1.81 2.75 2.63 1 7,8 DN100 ... .: 114.3 127 46 70 .: 67 = .25; J 3.5 6 6.625 6.50 1.81 2.75 3.65 1 18.1 DN150 168.3 165 46 70 93 25 8.2 4.2 DIMENSIONS Reducing Base Support Elbow No. R-10G r-C-E No. R-lOF r-c-E Ti T2 T2 C-E Ti 2576.4 mm 25"/64 mm T2 C-E III .25"/6.4 mm 25"/6.4 mm -�:� III T2 4 L F II T e AA H1J�LJA T1 Hl-g. . H2 View B B No.R-10G No.R-10F 90°Reducing Base Support Elbow 90°Reducing Base Support Elbow Size Groove x Groove Groove x Class 150 Flange* Actual Approx. Approx. Outside Weight Weight Nominal Diameter C to E H1 H2 T1 T2 (Each) C to E OF H1 H2 T1 T2 (Each) inches inches inches inches inches inches inches lb inches inches inches inches inches inches lb DN mm _ mm mm mm mm mm mm kg mm_ mm mm mm mm mm kg 6 x 4 6.625 x 4.500 9.19 ," 1/5 0.38 2.00 150 33.0___._9.19 9.00 ,1.25 0.38 2.00 1.50 46 00 DN150 014100 168.3 114.3 233 32 : 10 51 ,= 38 15.0 233 229 32 10 51 38 20,9 5 5563 9.00 1.50 0.38 2.00'``. 150 ' 37.0 9.00 10.00. 1.50 0.38 2.00 1.50 52.0 1413 229 38 10 51-r' 38 16.8 229 254 38 10 51 38 23.6 8 T x 6 8.625 x 6.625 10.50 2.13 0.38 2.00 1.50 51.0 10.50 11.00 2.13 0.38 2.00 1.50 70.0 DN200 DN150 219.1 168.3 267 54 10 51 38 23.1_ 267 279 54 10 51 38 31.8 10 x 8 10.750 x 8.625 12.00" 238 0,38 '2.00 1.50 88.0 12.00 13.50 238 -T0.38 2.00 150 118.0 DN250 DN200 273.0 219.1 305 60 10 51;. _ 38 39.9 305 I 343 60 10 51 38 53.5 Contact Victaulic for additional flange end options. For long radius base support elbow options,please refer to publication 07.13. 07.01 1449 Rev AJ Updated 05/2023 ®2023 Victaulic Company.All rights reserved. victaulic.com 8 \Ctaulic . r victaulic.com • 4.3 DIMENSIONS Adapter Elbow No. 18 90"Adapter Elbow �E No. 19 45"Adapter Elbow i �E r\ C to __6/- TE l TES No. 18 No. 19 90°Adapter Elbow 45°Adapter Elbow Size Groove x Male Thread' Groove x Male Threads Actual Outside Approx.Weight Approx.Weight Nominal Diameter C to GE C to TE (Each) C to GE C to TE (Each) inches inches inches inches inches inches inches lb DN mm mm mm mm mm mm kg . . 2.25 05 1.50 1.50 3/4 3:050 ' 5 03 = 2 0N20 26.9 57" 57 0.2 38 38, 0.2' 1 1.315 2.25 2.25 0.6 NA NA NA DN25 33.7 57 57 0.3 NA NA DN32 i: 42.4 70 70" 0.5 ,� . 1 1/2 1.900 2.75 2.75 1.4 1.88 1.75 0.9 DN40 48.3 70 70 0.7 48 44 0.4 2 .375. 3.2 - 4.25" 2.5 2.00 2A4"" ?.. DN50 603 83 108 1.1 51 51; ` 0.7 21/2 2.875 3.75 3.75 3.7 2.25 2.25 2.3 73.0 95 95 1.7 57 57 1.0 3 3 500 4.25 6.00. 56 " 2.50 4.25 5.0 ON80"° 889 108 ", 152 3.0 64 108 2.3 4 4.500 5.00 7.25 10.0 NA NA NA DN100 114.3 127 184 4.5 _ 6 6.625 6.50 ` 6.50 19.0 1. 3.50 3.50 10.8'. DN150 168.3 165 165 8.6 89 89 4.9 .: 1 Available with British Standard Pipe Threads,specify"BSP"clearly on order. NA=Not Available • ' 07.01 1449 Rev AJ Updated 05/2023 ©2023 Victaulic Company.All rights reserved. victaulic.com 9 jctatulic' victaulic.com 4.4 DIMENSIONS Tees, Crosses and True Wyes No. 20 rCtoE 1 cm "-GE-1 No. 29M II,I= c 11111,11 to c to TE it No.29M No.20 Tee Size Tee Groove x Male Thread2 Branch - � Actual -------"-- � Outside Approx.Weight Approx.Weight Nominal Diameter C to E (Each) C to GE C to TE (Each) inches inches inches lb inches lb inches DN mm mm kg mm kg mm 3A 1.050:" - - 2/5 - " .--;.:`0.8:, '';':.;2.25(sw) 2.25(sw) .. -.0.6 DN20. 26.9 57 0.4 -7 57 " 0.3 1 1.315 2.25 0.9 2.25(sw) 2.25(sw) 0.9 DN25 33.7 57 0.4 57 57 0.4 11/4 , ..1.660 . 2.75" 1.5 2.75 2.75 1.6" DN32, 42.4 70 0.7 70 70' :<4:7 11 1.900 2.75 1.7 2.75 2.75 1.8 DN40 48.3 70 0.8 70 70 0.8 2 2.375 3.25 2.8 ' 3.25 4.25 3.5 -- DN50 603 .83". °...,," "1:3 : 83 108 1.6 21/2 2.875 3.75 4.8 3.75(sw) 3.75(sw) 4.3 73.0 95 2.2 95 95 2.0 3.000 3;75 53 3.75(sw) 3.75(sw) " 5 2` , DN65. 76.1 3 3.500 4.25 6.4 4.25(sw) 4.25(sw) 7.2 DN80 88.9 108 2.9 108 108 3.3 31h 4.000 4.50(sw) 7.9 4.50(sw) 4.50(spy) 7 9" DN90 : '; : 101.6 ' 114 3.6 114 '114 3.6 4.250 5.00 12.0 5.00(sw) 5.00(sw) 15.5 108.0 127 5.4 127 127 7.0 , 4 4.500 5.00 11.3 500 7.25 163 DN100 114"3 127 5.1 127 184 7.4 " 41/2 5.000 5.25(sw) 15.0 5.25(sw) 5.25(sw) 15.0 127.0 133 6.8 133 _ 133 6.8 5.250 5.50 16.2 5.50(sw) 5.50(sw)"< 17.6",. 133.0 140 7.3 140 140 , 8.1 5.500 5.50 17.8 5.50(sw) 5.50(sw) 17.8 DN125 139.7 140 8.1 140 140 8.1 5 5.563 5.50 17.8 5.50(sw)" '' 5.50-(sw) 24.0 1413 140 _ .. 8.1 14010.9 6.000 6.50(sw) 6.50(sw) 6.50(sw) 25.7 152.4 165 + 165_ 165 11.7 6.250 6.50(sw) ^- 6:50(sw) 6.50(sw) 27.1 159.0 165 + 165" 165 12.3 6.500 6.50 25.0 6.50(sw) 6.50(sw) 28.0 165.1 165 11.3 165 165 12.7 6 6.625 6.50 25.7 6.50(sw) 6.50(sw) 33.0 DN 150 168.3 165: 11.7 165 165 15.0 200A 216.3 ! 7.75 43.3 NA NA NA 197 j 19.6 ' For 14"/DN350 and larger roll grooved systems for carbon steel pipe,Victaulic offers fittings for the Advanced Groove System(AGS).Refer to publication20.05 for more information.For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. 2 Available with British Standard Pipe Threads,specify"BSP"clearly on order. (sw)=Carbon Steel Segmentally Welded NA=Not Available "+"=Contact Victaulic for details NOTES • All fittings are ductile iron unless otherwise noted with an(sw). • • 07.01 1449 Rev AJ Updated 05/2023 ©2023 Victaulic Company.All rights reserved. victaulic.com 10 ✓ataulicr victaulic.com • • 4.3 DIMENSIONS (CONTINUED) Tees,Crosses and True Wyes No. 20 C to E•� to GE No. 29M iiiiiii C ligu to C to TE 1 No.29M No.20 Tee Size Tee Groove x Male Thread2 Branch Actual Outside Approx.Weight Approx.Weight Nominal Diameter C to E (Each) C to GE C to TE (Each) inches inches inches lb inches lb inches DN mm mm kg mm kg mm 8 8.625 7.15 49.5 7.75(sw) r`"7.75(sw) 47.6 0N200 219.1 197 .. 225 . 197 ' 197 21t6 250A 267.4 9.00 66.0 NA NA NA 229 29.9 10 10.750 " 9.00 72.4: ' 9.00(sW) 9.00(sw) 99.0 x DN250 273.0 229 32.8 229 229 44.9" 300A 318.5 10.00 95.0 NA NA NA T 254 _ 43.1 12 12.750 1.0.00 ; 1072 "10.00(sw) 10. 0 ism :.133.0 DN300, 323.9 _ 254," 48 + 254 254 60.3 14' 14.000 11.00(sw) 150.0 11.00(sw) 11.00(sw) + DN350 355.6 _279 _ 68.0 279 279 377.0 4 "" 292 -- 72.3 16' 16.000 12.00(sw) 188.0 12.00(sw) 12.00(sw) + DN400 406.4 305 85.3 305 305 16.772 13.00 211.6. NA NA NA ' 426.0 330 . 96.0 18' 18.000 15.50(sw) 200.0 15.50(sw) 15.50(sw) + DN450 457.2 394 90.7 394 394 18.898 14.57; 2111.E NA" Nit NA 4800 370. 96:0. " 20' 20.000 17.25(sw) 339.0 17.25(sw) 17.25(sw) + DN500 508.0 438 153.8 438 438 r"':: 40.:86.6. 15,39 3821) ;.NA , . NA - NA 530.0 391 173.3 22 22.000 19.00(sw) 468.0 19.00(sw) 19.00(sw) + DN550 558.8 483 212.3 483 483 241 • 24.000 20.00(sw) 592.0 2040(sw) 2000(SW)" DN600 609.6` - 508 268.5 ._. 1_ 508 , 508 24.803 I 17.37 502.0 NA NA NA 630.0 I 441 227.7 14-60 For AGS fitting information,see publication 20.05 DN350-DN1500 A GS- v ' For 14"/DN350 and larger roll grooved systems for carbon steel pipe,Victaulic offers fittings for the Advanced Groove System(AGS).Refer to publication 2005 for more information.For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. 2 Available with British Standard Pipe Threads,specify"BSP"clearly on order. (sw)=Carbon Steel Segmentally Welded NA=Not Available "+'=Contact Victaulic for details NOTES • All fittings are ductile iron unless otherwise noted with an(sw). • • 07.01 1449 Rev AJ Updated 05/2023 ©2023 Victaulic Company.All rights reserved. victaulic.com 11 jctaulie victaulic.com . . 4.4 DIMENSIONS • Tees, Crosses and True Wyes No. 33 ` �� 'CtoEi No. 35 Cto E` ell No.33 No.35 Size True Wye Cross Actual Outside ( Approx.Weight Approx.Weight Nominal Diameter C to LE C to SE (Each) C to E (Each) inches inches inches inches lb inches lb DN mm mm mm kg mm kg 1/4 „ 1.050 2:25(sw) 2.00(sw) 0.8 2.25,(Sw) 0.9 011120 _26,9. 57 51 04 57 044 __ 1 1.315 2.25(sw) 2.25(sw) 1.1 2.25(sw) 1.3 DN25 33.7 57 I 57 0.5 57 0.6 1'/a 1.660 2.75(sw) = 2.50(sw) 1.5 2.75(sw) 2.1 DN32 42:4 70 64 0.7 70 1.0 11/2 1.900 2.75(sw) 2.75(sw) 1.8 2.75(sw) 2.5 DN40 48.3 70 70 0.8 70 1.1 2 2,375 3.25(sw) ° r: 2.75(sw) 2.5 r 3.25 4.0 DN50 60.3; 83 70 1.1 83 1.8 21/2 2.875 3.75(sw) 3.00(sw) 5.1 3.75 6.1 73.0 95 76 2.3 95 2.8 3:000 ~3.75(sw) 3.25(sw) 5.5", 3.75 7.8 0N65 76.1,.. '., 95 83 2.5: ,_: 95 3.5 3 3.500 4.25(sw) 3.25(sw) 6.1 4.25 11.8 DN80 88.9 108 83 2.8 108 _ 5.4 T 31 4.000 4.50(sw) 3.50(sw) 9.6- 4.50(sw)ry 11.5 DN90 - - 101.6 ,, 114 � 89 4.4 114 5.2 4.250 5.00(sw) 3.75(sw) 9.7 5.00 18.4 108.0 127 95 4.4 127 8.3 4 4.500 - 5.00 3.75 10.0 5.00 15.8 DN100 114.3 127 95 - 4.5 127 7,2 41/2 5.000 5.25(sw) 4.00(sw) 12.5 5.25(sw) 18.5 127.0 133 102 5.7 133 8.4 5.250 5.50(sw) 4.00(sw) 13.8 5.50(sw) 19.0 133.0 140 102 6.2, 140 ", 8.6 5.500 5.50(sw) 4.00(sw) 15.0 5.50(sw) 19.5 DN125 139.7 140 102 6.8 140 8.8 5 5.563 5.50(sw) 4.00{;w) 15.0 , 5.50 ,28.6 141.3 140 102.. 6.8 _ 140 13.0 6.000 6.50(sw) 4.50(sw) 17.5 6.50(sw) 22.0 152.4 165 114 7.9 _165 10.0 6.250 6.50(sw) 4.50($w) 19.9 -__.. 6.50 414 159.0 165 114 9.0 165 18.8 6.500 6.50(sw) 4.50(sw) 21.5 -�" 6.50 44.0 165.1 165 114 9.8 165 20.0 6 6.625 6.50(sw) 4.50(sw) 22.3m 6.50 46.0 DN150 168.3 165 . 114 10.1 165 20.9 8 8.625 7.75(sw) 6.00(sw) 36.0 7.75(sw) 48.0 DN200 219.1 197 152 16.3 197 21.8 1 For 14"/DN350 and larger roll grooved systems for carbon steel pipe,Victaulic offers fittings for the Advanced Groove System(AGS).Refer to publication 20 05 for more information.For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. (sw)=Carbon Steel Segmentally Welded NOTE • All fittings are ductile iron unless otherwise noted with an(sw). • 07.01 1449 Rev AJ Updated 05/2023 ©2023 Victaulic Company.All rights reserved. victaulic.com 12 ✓ctaulic victaulic.com 4.4 DIMENSIONS (CONTINUED) Tees,Crosses and True Wyes No. 33 -CtoEi o. 35 Ct°E`N iiIi -------- ---------- - No.33 No.35 Size True Wye Cross Actual Outside Approx.Weight Approx.Weight Nominal Diameter C to LE C to SE (Each) C to E (Each) inches inches inches inches lb inches lb DN mm mm mm kg mm kg 10 : " 1O 750:` 9.00(sw) 6.50(sw) 54.5 9.00(sw) a0.0 ' 250 273,0. 229 '..165 24.7 229 31.8 12 12.750 10.00(sw) 7.00(sw) 80.0 10.00(sw) 110.0 DN300 323.9 254 178 36.3 254 49.9 14' ::. "14.000 " 11.00(svt') 7'50(sv) 134,2 - 11.00(sw) 4 1988 0N350= '. .' 355.6' 279 191 60.9 279 898 16' 16.000 12.00(sw) 8.00(sw) 167.0 12.00(sw) 250.0 DN400 406.4 305 203 75.7 305 - 113.4 18' 18400 15.50(sw)" 8.50(sw) 180.0 ':15 50(star),5 350.0 0N450 457.2 '; 394I ." 216 81.6 394 158.8 20' 20.000 17.25(sw) 9.00(sw) 200.0 17.25(sw) 452.0 DN500 508.0 438 229 90.7 438 205.0 22 22.000 19.00(sw){. 9.50(sw)" " 225.0..; 19.00(sw) 624.0 DN550 _ : '558.8 : 483 241 102.1 483 283.0 24' 24.000 20.00(sw) 10.00(sw) 250.0 20.00(sw) 795.0 DN600 609.6 508 254 113.4 508 360.6 For AGS fitting information,see publication 20.05 14-60 DN350-DN1 500 AGS" 1 For 14'/DN350 and larger roll grooved systems for carbon steel pipe,Victaulic offersfittings for the Advanced Groove System(AGS).Refer to pu-blication 20.05 for more information.For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. (sw)=Carbon Steel Segmentally Welded NOTE • All fittings are ductile iron unless otherwise noted with an(sw). • • 07.01 1449 Rev AJ Updated 05/2023 C 2023 Victaulic Company.All rights reserved. victaulic.com 13 jctaulie victaulic.com 4.4 DIMENSIONS (CONTINUED) Reducing Tee No. 25 j.ctoE1l ctoE.1 No. 29T No. 29F II 1i c II Ii c to to No.29T _....No.29F2 No.25 Reducing Tee Reducing Tee Grooved Branch Groove x Male Thread2 Groove x Female Thread2 Size I Reducing Tee Branch Branch Approx. Approx. Approx. Weight Weight Weight Nominal Actual Outside Diameter C to E (Each) C to E (Each) C to E (Each) inches inches inches lb inches lb inches lb DN mm mm kg mm kg mm kg 1 x 1` ' x 3/4 i 1.315 x 1.315 x 1;050 2.25(sw) : 0.8 ' 2,25(sw) 0.8 NA NA " 1 DN25 DN25 DN20 : 33.7 33.7 26.9 57 0.4 '.57 0.4 1% x 1 1/4 x 3/4 1.660 x 1.660 x 1.050 2.75(sw) 1.0 2.75(sw) 1.0 NA NA DN32 DN32 DN20 42.4 42.4 26.9 70 0.5 70 0.5 1 1.315 2.75(sw) 1.3 2.75(sw) 1.5 NA NA DN25 _ 33.7 70 0.6 70 0.7 1 x 11A x 3 1.900 x 1.900 x 1.050 2.75(sw) ,_ 1.5 2.75(sw) 1,5 NA NA_. DN40 ON40 DN20" ..48,3 48.3 26.9 .. 70 0.7 70 0.7 1 1.315 2.75(sw) 1.5 2,75(sw) 1.8:: NA NA DN25 33.7 70 0.7 70" . 0.8:' ,1 '/4 1 1.660 2.75(sw)" 2.1 " 2.75(sw) 1.7 . DN32 42.470 1.0 70 0,8 NA NA w 2 x 2 x % 2.375 x 2.375 x 1.050 3.25 2.5 3.25 2.5 NA NA DN50 DN50 _ DN20 60.3 60.3 26.9 83 _ 1.1 83 1.1 1 1.315 3.25 2.7 3.25 2.7 NA NA DN25 33.7 83 1.2 83 1.2 1'/4 1.660 3.25(sw) 2.3 3.25(sw) 23 NA NA DN32 42.4 83 1.0 83 1.0 11/2 1.900 3.25 3.2 3.25 3.2 NA NA DN40 48.3 83 1.5 83 1.5 214" x 21/2 x 3/4 2.875 x 2.875 x 1.050 3.75(sw) 3.9 3.75(sw) 3.0 NA NA DN20 73.0 73.0 26.9 95 ' ' 1.8 95 1.4 1 1.315 3.75 ' 3.8 ' 3.75 3.8 NA NA DN25 33.7 , 95 1.7 95 1.7 1'% 1.660 .3.75 4.0 3.75 4.0 NA NA DN32, 42.4 95 1.8 , 95 1.8 _ 13/2 1.900 3.75 4.8 3.75 4.8 NA NA DN40 48,1 95 2.2 95 2.2 _ 2 2,375" 3.75 .4.5. 3.75 4:5 NA NA _ DN50 60.3 95 --2 0 95 _2.0 x x 3/4 3.000 x 3.000 x 1.050 3.75(sw) 3.75(sw) DN65 DN65 DN20 76.1 76.1 26.9 95 + 95 - - + NA NA 1 1.315 i 3.75(sw) 3.75(sw) DN25 33.7 95 + 95 + NA NA 1% 1.660 3.75(sw) 3.75(sw) DN32 42.4 95 + _ 95 + NA NA 1 1 1.900 3.75(sw) 3.75(sw) DN40 48.3 95 _ + 95 + NA NA 2 2.375 iI 3.75 4.6 3.75 4.6 NA NA DNSO 60.3 I 95 2.1 95 2.1 ' For 14"/DN350 and larger roll grooved systems for carbon steel pipe,Victaulic offers fittings for the Advanced Groove System(AGS).Refer to p blic at on 20.05 for more information.For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. 2 Available with British Standard Pipe Threads,specify"BSP"clearly on order. (sw)=Carbon Steel Segmentally Welded NA=Not Available "+'=Contact Victaulic for details NOTES • All fittings are ductile iron unless otherwise noted with an(sw). • 07.01 1449 Rev AJ Updated 05/2023 (C)2023 Victaulic Company.All rights reserved. 4 victaulic.com 14 �ctaulic a r victaulic.com 4.4 DIMENSIONS (CONTINUED) Reducing Tee No. 25 r-ctoEl i ctoE-1 No. 29T No. 29F II1 c 11,1 11, 11 No.29T No.29F2 No.25 Reducing Tee Reducing Tee Grooved Branch Groove x Male Thread2 Groove x Female Thread2 Size Reducing Tee Branch Branch Approx. Approx. Approx. Weight Weight Weight Nominal Actual Outside Diameter C to E (Each) C to E (Each) C to E (Each) inches inches inches lb inches lb inches lb DN mm mm kg mm kg mm kg 3 )c, - 3 x :, 3,4 ;;. 3500 .i: 3.500 'x 1.050 , 4.25(sw) 5.7 4.25(sw) 5.7 NA NA DN80 DN80 ..:{DN20 88.9 88.9 = 26.9 108 2.6-, 108 , 2.6 ' 1 1.315 4,25 6.0, 4.25 . 6.0 NA NA DN25 33.7 108 2.7 .. 108 2.7 1?/s '.1.660 425 6.0 4.25 6.3 NA NA DN32 424 108 2.7 108. 2.9 . 1 1/2: 1.900 4.25 '(' 6.6 5 DN40 48.3 108 3.0. 08 30 D1450 60,3 '108 2.8 108 2.8 108 2.8 2�h 2.875 4.25 6.6. 4.25 6.6 73.0 > 108 3.0 " 108 3.0 AlA NA 3.0004.25 11.6 NA NA DN65 `: 76.1 108 3.1 108 5.3 31/2 x 31/2 x 3/4 4.000 x 4.000 x 1.050 4.50(sw) + 4.50(sw) + NA NA DN90 DN90 DN20 101.6 101.6 26.9 114 114 1 1.315 1 4.50(sw) 4.50(sw)+ + NA NA DN25 33.7 114 114 1 1/4 1.660 ( 4.50(sw) + 4.50(sw) + NA NA DN32 42.4 114 114 11/2 1.900 4.50(sw) + 4.50(sw) + NA NA DN40 48.3 114 114 2 2.375 4.50(sw) 4.50(sw) + + NA NA DN50 60.3 114 114 a- - - 2 1/2 2.875 4.50(sw) + 4.50(sw) + NA NA 73.0 114 114 -- 3 3.500 4.50(sw) + 4.50(sw) + NA NA DN80 88.9 114 114 4.250 x 4.250 "x 1.050' 5.00(sw) 5.00(sw) 5.00(sw) 108.0 108.0 26.9 127 + 127 127 + 1315 5.00(sw) ; 5.00(sw) 5.00(sw) 33.7 127 + 127 + 1 27 + ,. 1.660 5.00(sw) 5.00(sw) 5.00(sw) 42.4 127 + 127 + 127 1.900 5.00(sw) = 5.00(sw) 5.00(sw) 48.3 127 + 127 + 127 + 2.375' 5.00(sw) 5.00(sw) 5.00(sw) 60.3 127 + 127 + . 127 + 3.000 5.00(sw) 5.00(sw) - 5.00(sw) 76.1 127 ' 127 . + 127 + 3.500 5.00 95 5.00(sw) 88.9 127 4.3 127 + NA NA , For 14"/DN350 and larger roll grooved systems for carbon steel pipe,Victaulic offers fittings for the Advanced Groove System(AGS).Refer to publication 20.05 for more information.For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. 2 Available with British Standard Pipe Threads,specify"BSP"clearly on order. (sw)=Carbon Steel Segmentally Welded NA=Not Available "+"=Contact Victaulic for details NOTES • All fittings are ductile iron unless otherwise noted with an(sw). • • 07.01 1449 Rev AJ Updated 05/2023 C 2023 Victaulic Company.All rights reserved. victaulic.com 15 ✓ataulic victaulic.com • • 4.4 DIMENSIONS (CONTINUED) Reducing Tee No. 25 -CtoE»I CtoE.1 No. 29T - - No. 29F II II c IV: c toto ii 1 Z� No.29T No.29F2 No.25 Reducing Tee Reducing Tee Grooved Branch Groove x Male Thread2 Groove x Female Thread2 Size Reducing Tee Branch Branch Approx. Approx. Approx. Weight Weight Weight Nominal Actual Outside Diameter C to E (Each) C to E (Each) C to E (Each) inches inches inches lb inches lb inches lb DN mm mm kg mm kg mm kg 4 x 4 x 3/4 4.500 x 4.500 x 1.050 5.00(sw) 8.0 5.00(sw) 9.3 NA NA DN100 DN100 DN20 114.3 114.3 26.9 127 3.6 127 4.2 1 1.315 5.00 9.1 5.00 9.1 NA NA DN25 33.7 127 4.1 127 4.1 1 t/4 1.660 5.00(sw) 8.9 5.00(sw) 10.0 NA NA DN32 42.4 127 4.0 127 4.5 1 t/2 1.900 5.00 10.2 5.00 10.2 NA NA DN40 48.3 127 4.6 127 4.6 2 2.375 5.00 11.2 5.00 11.2 NA NA DN50 60.3 127 5.1 127 5.1 21 2.875 5.00 11.5 5.00 11.5 NA NA 73.0 127_ 5.2 127 5.2 3.000 5.00 10.3 5.00 10.3 NA NA DN65 76.1 127 4.7 127 4.7 3 3.500 5.00 11.6 5.00 11.6 NA NA DN80 88.9 127 5.3 127 5.3 5.250 x 5.250' x 1050 550(sw) 5.50(sw) 550.(sw)' 133.0 1n0 Zb.9 140 + 140 + 140 3 + 1.315 5.50(sw) 5.50(sw) 5.50(sW) 1660 5.50(sw) 5:50(sw) 5.50(sw) °; 1.900 , -5,50(sw) 5.50(sw),' 5.50(sw) ?i8,3 ... : 140 +. 140 + 140 2375 5,50(sw) ? 5.50(sw) .. 60.3 140 + 140 + NA NA 3.000 5.50(sw) 5,50(sw) 5:50(sw)-.. 76.1 " 140 + 1.40 + 140 + 3500 5,50(sw) 5.50(sw) 5.50(swj. 88.9 ;. 140 + . ... 140 + 140 +. .. 4.250 5,50 12.9';... 5.50:(sw) + NA NA 1 108.0 =_"" '140 5.9 140 .: 1 For 147DN350 and larger roll grooved systems for carbon steel pipe,Victaulic offers fittings for the Advanced Groove System(AGS).Refer to publication 20.05 for more information.For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. 2 Available with British Standard Pipe Threads,specify"BSP"clearly on order. (sw)=Carbon Steel Segmentally Welded NA=Not Available "+"=Contact Victaulic for details NOTES • All fittings are ductile iron unless otherwise noted with an(sw). • • 07.01 1449 Rev AJ Updated 05/2023 ©2023 Victaulic Company.All rights reserved. victaulic.com 16 ✓ctaulic' victaulic.com 4.4 DIMENSIONS (CONTINUED) Reducing Tee No. 25 'ctoEi i ctoE No. 29T No. 29F II ! 'i c II 1� c _ y tO il i + No.29T No.29F2 No.25 Reducing Tee Reducing Tee Grooved Branch Groove x Male Thread2 Groove x Female Thread2 Size Reducing Tee Branch Branch Approx. Approx. Approx. Weight Weight Weight Nominal Actual Outside Diameter C to E (Each) C to E (Each) C to E (Each) inches inches inches lb inches lb inches lb DN mm mm kg mm kg mm kg x x 3/4 5.500 x 5.500 x 1.050 5.50(sw) 5.50(sw) + + NA NA DN125 DN125 DN20 139.7 139.7 26.9 140 140 1 1.315 5.50(sw) 5.50(sw)+ + NA NA DN25 33.7 140 140 _ 1 1/4 1.660 5.50(sw) 5.50(sw)+ + NA NA DN32 42.4 140 140 1 1 1.900 5.50(sw) 5.50(sw) + + NA NA DN40 48.3 140 140 2 2.375 5.50 13.5 5.50(sw) + NA NA DN50 60.3 140 6.1 140 3.000 5.50(sw) 5.50(sw) + + NA NA DN65 76.1 140 140 3 3.500 5.50 13.8 5.50(sw) DN80 88.9 140 6.3 140 + NA NA 4.250 5.50(sw) 5,50(sw) + + NA NA 108.0 140 _ 140 4 4.500 5.50 14.4 5.50(sw) + NA NA DN100 114.3 140 6.5 140 5 at 5.' "x ` aA 5.563 x 5.563 x 1.050 5.50(sw) . 5.50(sw). DN20 141.3 141.3 26.9 ".140 + 140 + NA , ;;NAl. 1 -1315 5.50(Sw) ' 14.0 5.50(sw) 14.0 " DN25 "" 33 7 140 6A 140 6.4 1VA NA 11 1660.: 5.50(sw). _' + 5,50"(sw) + NA NA. . DN32 42 4 140 140 1 t/2 1.900 " 5.50(sw) 14,3 5.50(sw) " 14.5 DN40 48 3 140 6.5 140 6.6 NA" .i 2 2.375 5.50(sw) 14.5 5:50(sw) 14.5 NA` NA (7N5(! 60 3 r i 140 4,6" )44 6.6 21/2 . 2.875 '5.50 15.5 5.50 `' 15.8 NA NA 14© 7,0 1"90 7.2. 3 3.500 5.50 12.6 5,50.(sw), 17.0 ' ON80 88.9" 140" 5.7 140 77 NA NA " 4 4.500,;. 550'. . 16.0 5.50(sW) " 16.0 NA NA 'DN100 114,3': " 140 :.-a: . "'7.3 140 7.3 1 For 14"/DN350 and larger roll grooved systems for carbon steel pipe,Victaulic offers fittings for the Advanced Groove System(AGS).Refer to publication 20.05 for more information.For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. 2 Available with British Standard Pipe Threads,specify"BSP"clearly on order. (sw)=Carbon Steel Segmentally Welded NA=Not Available "+"=Contact Victaulic for details NOTES • All fittings are ductile iron unless otherwise noted with an(sw). • • 07.01 1449 Rev AJ Updated 05/2023 ©2023 Victaulic Company.All rights reserved. victaulic"com 17 ✓ctl ulic victaulic.com • 4.4 DIMENSIONS (CONTINUED) Reducing Tee No. 25 f-CtoE»I -I CtoE. No. 29T No. 29F 1111 [ 111I 11, 11 to No.29T No.29F2 No.25 Reducing Tee Reducing Tee Grooved Branch Groove x Male Thread2 Groove x Female Thread2 Size _ Reducing Tee Branch Branch Approx. Approx. Approx. Weight Weight Weight Nominal Actual Outside Diameter C to E (Each) C to E (Each) C to E (Each) inches inches inches lb inches lb inches lb DN mm mm kg mm kg mm kg 6.000 x 6.000 x 1.050 6.50(sw) 6.50(sw)+ + NA NA 152.4 152.4 26.9 165 165 1.315 6.50(sw) 6.50(sw)+ + NA NA 33.7 165 165 1.660 6.50(sw) 6.50(sw)+ + NA NA 42.4 165 165 1.900 6.50(sw) 6.50(sw)+ + NA NA 48.3 165 165 2.375 6.50(sw) 6.50(sw)+ + NA NA 60.3 165 165 3.000 6.50(sw) 6.50(sw)+ + NA NA 76.1 165 165 3.500 6.50(sw) 6.50(sw)+ + NA NA 88.9 165 165 4.250 6.50(sw) 6.50(sw)+ + NA NA 108.0 __, 165 165 4.500 6.50(sw) 6.50(sw)+ + NA NA 114.3 165 165 5.250 6.50(sw) 6.50(sw)+ + NA NA 133.0 165 165 1 For 14"/DN350 and larger roll grooved systems for carbon steel pipe,Victaulic offers fittings for the Advanced Groove System(AGS).Refer to publication 2005 for more information.For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. 2 Available with British Standard Pipe Threads,specify"BSP"clearly on order. (sw)=Carbon Steel Segmentally Welded NA=Not Available "+"=Contact Victaulic for details NOTES • All fittings are ductile iron unless otherwise noted with an(sw). • • 07.01 1449 Rev AJ Updated 05/2023 ©2023 Victaulic Company.All rights reserved. victaulic.com 18 ✓ctauhe victaulic.com 4.4 DIMENSIONS (CONTINUED) Reducing Tee No. 25 ,-ctoE-1 i ct°E-1 No. 29T - i No. 29F -i---- --1- II1u7 I I II ! t° r--5 i ����--------_ No.29T No.29F2 No.25 Reducing Tee Reducing Tee Grooved Branch Groove x Male Thread2 Groove x Female Thread2 _ Size Reducing Tee Branch Branch Approx. Approx. Approx. Weight Weight Weight Nominal Actual Outside Diameter C to E (Each) C to E (Each) C to E (Each) inches inches inches lb inches lb inches lb DN mm mm kg mm kg mm kg 6.250 " x 6.250 z 1.050 630(sw) : " 6.50(sw) 6.50(sw) 159.0 159.0 26.9 165 - + 165 + 165 + 1.315 6.50(sw) 6.50(sw) 6.50(sw) 33.7 165 + 165 + ' 165 1.660 6.50(sw) 6.50(sw) `>.6.50;(sW) 424 . 365 + 165 165 : " + '.. 1.900 6.50(sw) 6.50(sw) 6.50(sw) :. , 483 165 +' 165 + 2375 650(sw) 6.50(sw) 6.50(sw) 60.3. ., 165 *:_ 165 + 165 '' - } , 3,000 . .6.50(sw) + 6.50(svv): . 4, 6.50(sw)" + 761 165 165'." 165 3.500 630 18.5 6.50(sw,) ." + NA NA St#9 165 8.4 165 4.250 6.50 183 630(sw) NA NA 1080 165 8.4 s 1G5.'. 4500 <6.50 7 '12.1 15.50(Sw) 11.4.3. ' 165. 55 . ' 165 + NA NA 5.250 6.50 19.0 6.50(sw) + NA NA 133,0 165 8.6 165 _ 6.500 x 6.500 x 1.050 6.50(sw) 6.50(sw)+ + NA NA 165.1 165.1 26.9 165 165 1.315 6.50(sw) 10.8 6.50(sw) 10.8 NA NA 33.7 165 4.9 165 4.9 1.660 6.50(sw) 11.0 6.50(sw) 11.0 NA NA 42.4 165 5.0 165 5.0 1.900 6.50(sw) 11.3 6.50(sw) 113 NA NA 48.3 165 5.1 165 5.1 2.375 6.50 18.9 6.50 18.9 NA NA 60.3 165 8.6 165 8.6 3.000 6.50 20.0 6.50(sw) + NA NA 76.1 1 165 9.1 165 3.500 ' 6.50 24.3 6.50(sw) + NA NA 88.9 165 11.0 165 4.500 6.50 23.8 6.50(sw) + NA NA 114.3 165 10.8 165 5.500 6.50 26.0 6.50(sw) + NA NA 139.7 165 11.8 165 1 For 147DN350 and larger roll grooved systems for carbon steel pipe,Victaulic offers fittings for the Advanced Groove System(AGS).Refer to publication 20.05 for more information.For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. 2 Available with British Standard Pipe Threads,specify"BSP"clearly on order. (sw)=Carbon Steel Segmentally Welded NA=Not Available "+"=Contact Victaulic for details NOTES • All fittings are ductile iron unless otherwise noted with an(sw). • 07.01 1449 Rev AJ Updated 05/2023 ©2023 Victaulic Company.All rights reserved. victaulic.com 19 ✓ctaulic' victaulic.com • • 4.4 DIMENSIONS (CONTINUED) Reducing Tee No. 25 jctoE1l ctoEl No. 29T No. 29F VI c II Ii c _ _ to to li y No.29T No.29F2 No.25 Reducing Tee Reducing Tee Grooved Branch Groove x Male Thread2 Groove x Female Thread2 Size Reducing Tee Branch Branch _ Approx. Approx. Approx. Weight Weight Weight Nominal Actual Outside Diameter C to E (Each) C to E (Each) C to E (Each) inches inches inches lb inches lb inches lb DN mm mm kg mm kg mm kg 6 x 6 x 4'":"" 6.625 x 6.625 x "1.050 630(sw) + 6.50(sw) + £" NA NA DN150 DN150 DN20 168:3 168.3 26,9 165 165 .. 1 1.315 6.50{sw) 23.0 6.50(sw) 23.0 NA NA :'"" DN25 33,7 "" ' 165 10.4 165, 10.4 ` 1 Y,. 1.660" 6650(sw) :.. 25.0 .6,50(sw)_" 25.0 DN32 42.4 165" . 1 .3"": .; " ",165 11:3 NA..: NA 1'h 12900 6.50(sw) :' 25.0 . 6.50(sw) 25.0 DN40 483 165 '- , " , 11.3'<; 165 113 NA NA 2 :' 2,375 :. 6.50 22.8 6.50 " " 22:8; NA NA . .` ..DN50 60 3 165 10:3 165 10.3 2'h 2 875 6 5fl 23.8 6,Si1" 25.2 73.0 " 165 10.8 165 .:: ':'11.4' NA NA J 6:50 DN65 •76.1 165" + ,, 165 + NA NA 3: 3.500 = 6.50 24.8 " 6,50 24.9 DN80` 88.9 ' 165 113 165 11,3 :" NA NA _ 4 4:500 6.50 24.8 6.50 22.1 ": 7 DN100 " " 114.3 165 11,2 165 10,0 NA NA 5,500 6.50(sw) ;+ 6.50(sw) 24- NA NA DN125 139.7 165 165 5 .. -5.563 6.50 26.7 6.50(sw). 26.7 141.3 165 12.1 165 : . 12.1 NA NA 200A x 200A x 65A 216.3 x 216.3 x 76.3 7.75(sw) + NA NA NA NA 197 100A 114.3 7.75(sw) + NA NA NA NA 197 165A I 7.75 50.0 NA NA NA NA _I 197 22.7 1 For 14"/DN350 and larger roll grooved systems for carbon steel pipe,Victaulic offers fittings for the Advanced Groove System(AGS).Refer to publication 20,05 for more information.For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. 2 Available with British Standard Pipe Threads,specify"BSP"clearly on order. (sw)=Carbon Steel Segmentally Welded NA=Not Available "+"=Contact Victaulic for details NOTES • All fittings are ductile iron unless otherwise noted with an(sw). • 07.01 1449 Rev AJ Updated 05/2023 ©2023 Victaulic Company.All rights reserved. victaulic.com 20 ✓otaulia' victaulic.com • •4.4 DIMENSIONS (CONTINUED) Reducing Tee No. 25 �ctoE.l r ctoE. No. 29T ! - -No. 29FII Iic IV! c _toto 4 No.29T No.29F2 No.25 Reducing Tee Reducing Tee Grooved Branch Groove x Male Thread2 Groove x Female Thread2 Size Reducing Tee Branch Branch Approx. Approx. Approx. Weight Weight Weight Nominal Actual Outside Diameter C to E (Each) C to E (Each) C to E (Each) inches inches inches lb inches lb inches lb DN mm mm kg mm kg mm kg 8 x 8 x. M 8.625 x 8.625 : x 1.050 7.75(Sw) 7.75(sw). 7.75(sw) DN200 DN200 DN20 . 219.1. 219.1 26.9 197 + 197, + 197.: 1 , 1.315; 7.75(sw) 7.75(Sw)y 7.80(sw) DN25 .' 33.7 197 + 197 + t 98 + 1�/a . .. 1.660 7.75(sw) 7.75(sw). . 7.80(sw) DN32 42.4 - 197 * 197 + 198 1'/2 1.900 7.75(sw) :. 33.0 : 7.75(sw) 37.7 7.80(sw) , + DN40 48.3 197 ' 15.0 197 17.1.,.. - 198 2 2.375 7.75(sw) 33.5- 7.75-(Sw) 33,5. , ' DN50 60.3 197 - 15.2 197 15.2., CIA NA" , 21/2 2.875 7.75 373 7.75(sw) ' 34.0 ' NA NA 73.0 197 16.9 197' 15.4 . 3,000 7.75(sw) 37.5 :. 7.8(sw) DN65 76.1 197 17.0 NA. NA .' '....` 19$ �' '- DN80 88.9 197 17.0 197- 15.2 NA NA, 4250 7 75 48.9 NA NA NA NA 108.0 197 222 4 4.500 7.75 42.9 : .' 7.75(sw) . 35.0, ' DN100 ' 114.3 . 197 19.5 197 15.9 NA . NA 5.250 9.02 54.6 7.75(sw) + NA NA 133.0 229 24.8 197 5.500 7.75(sw) + NA NA NA NA DN 126 139.7 197 5 - 5.563 7.75 37.0 7.75(sw) 37.0 NA NA 141.3 197 16.8 197 16.8 , 6250 '; 7,75 516 715(sw) 159.0 197 23.4 197 + NA NA 6.500 -. , 7.75 43.2_,- 7.75(sw) + NA - NA 165,1 ' 197 19.6 - 197 6 6.625 7.75 48.5 7.75(sw) 43.0 DN150 168.3 197 - 22.0 197 19.5 NA NA 10.528 10.528 6.500 9.02 68.4 _ NA NA NA NA 267.4 267.4 165.1 229 31.0 250Ar. x 250A x 125A 267A . x 267,4 . x 139.8 9.00(sw) + NA NA NA NA . 229 200A 216.3 29.00 82.0 29 37.2 NA NA NA NA i For 14"/DN350 and larger roll grooved systems for carbon steel pipe,Victaulic offers fittings for the Advanced Groove System(AGS).Refer to publication 20.05 for more information.For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. 2 Available with British Standard Pipe Threads,specify"BSP"clearly on order. (sw)=Carbon Steel Segmentally Welded NA=Not Available "+"=Contact Victaulic for details NOTES • All fittings are ductile iron unless otherwise noted with an(sw). • • 07.01 1449 Rev AJ Updated 05/2023 ©2023 Victaulic Company.All rights reserved. victaulic.com 21 ✓c1taulic victaulic.com • • 4.4 DIMENSIONS (CONTINUED) Reducing Tee No. 25 bctoE»I ctoE-1 No. 29T i - 111i4No. 29F - I' 1 + :i....., ,.....:: No.29T No.29F2 No.25 Reducing Tee Reducing Tee Grooved Branch Groove x Male Thread2 Groove x Female Thread2 Size Reducing Tee Branch Branch Approx. Approx. Approx. Weight Weight Weight Nominal Actual Outside Diameter C to E (Each) C to E (Each) C to E (Each) inches inches inches lb inches lb inches lb DN mm mm kg mm kg mm kg 10 x 10 x 3/4 10.750 x 10.750 x 1.050 9.00(sw) 9.00(sw) DN250 DN250 DN20 273.0 273.0 26.9 229 + 229 + NA NA 1 1.315 9.00(sw) + 9.00(sw) + NA NA DN25 33.7 1 229 229 -- ------ --------- -- 1% 1.660 I 9.00(sw) 9.00(sw) DN32 42.4 229 + 229 + NA NA 1 1h 1.900 9.00(sw) 57.0 9.00(sw) 57.0 DN40 48.3 229 25.9 229 25.9 NA NA 2 2.375 9.00(sw) 62.0 9.00(sw) 65.0 9.00(sw) + DN50 60.3 229 28.1 229 29.5 229 21/2 2.875 9.00 62.5 9.00(sw) 53.0 73.0 229 28.3 229 24.0 NA NA �3.000 9.00(sw) 71.2 NA NA NA NA DN65 76.1 229 32.3_ 3 3.500 9.00 62.1 9.00(sw) 60.0 DN80 88.9 229 28.2 229 27.2 NA NA 4.250 9.02 77.6 9.00(sw) + NA NA 108.0 229 35.2 229 4 4.500 9.00 61.0 9.00(sw) 61.0 DN100 114.3 229 27.7 229 277 NA NA 5.250 9.02 84.2 9.00(sw) + NA NA 133.0 229 38.2 229 - - 5.500 9.00(sw) 9.00(sw) DN125 139.7 229 + 229 + NA NA 6.250 9.02 84.9 9.00(sw) + NA NA 159.0 229 38.5 229 5 5.563 9.00(sw) 52.0 9.00(sw) 52.0 141.3 229 23.6 229 23.6 NA NA 6.250 9.00 61.0 9.00(sw) + NA NA 159.0 229 27.7 229 6.500 9.00 64.2 9.00(sw) + NA NA 165.1 229 29.1 229 6 6.625 9.00 59.0 9.00(sw) 60.0 NA NA DN150 168.3 229 26.8 229 27.2 8 8.625 9.00 64.7 9.00(sw) 64.7 DN200 219.1 229 29.3 229 29.3 NA NA 300A x 300A x 150A 318.5 x 318.5 x 165.2 10.00(sw) 1 254 + NA NA NA NA 200A 216.3 10.00(sw) + -NA' NA mm NA NA 254 250A 267.4 10.00. 111.0 NA NA NA NA 1 For 14"/DN350 and larger roll grooved systems for carbon steel pipe,Victaulic offers fittings for the Advanced Groove System(AGS).Refer to publication 20.05 for more information.For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. 2 Available with British Standard Pipe Threads,specify"BSP"clearly on order. (sw)=Carbon Steel Segmentally Welded NA=Not Available "+"=Contact Victaulic for details NOTES • All fittings are ductile iron unless otherwise noted with an(sw). • •07.01 1449 Rev AJ Updated 05/2023 ©2023 Victaulic Company.All rights reserved. victaulic.com 22 �Ct9Ulic victaulic.com • •4.4 DIMENSIONS (CONTINUED) Reducing Tee No. 25 r-ctoE»I ctoE»I No. 29T No. 29F 11,111 c 111I c 11, 11 to to - --------..---T- - No.29T ------No.29F2 -- I No.25 Reducing Tee Reducing Tee Grooved Branch Groove x Male Thread2 Groove x Female Thread2 Size Reducing Tee Branch Branch Approx. Approx. Approx. Weight Weight Weight Nominal Actual Outside Diameter C to E (Each) C to E (Each) C to E (Each) inches inches inches lb inches lb inches lb DN mm mm kg mm kg mm kg 12 x 12 x 3/4 12.750 x 12.750 x 1.050 10.00(sw) + NA NA 10.00(sw) + DN300 DN300 DN20 323.9 323.9 26.9 254 254 1 1.315 10.00(sw) 70.0 10.00(sw) 77.0 10.00(sw) + DN25 33.7 I 254 31.8 254 254 - - 1 1/4 1.660 10.00(sw) 10.00(sw) 10.00(sw) DN32 42.4 254 + 254 + _ 254 + 11/2 1.900 10.00(sw) 10.00(sw) 10.00 DN40 48.3 254 + 254 + 254 + 2 2.375 10.00(sw) 78.0 10.00(sw) 78.0 10.00(sw) + DN50 60.3 254 35.4 254 35.4 254 21/2 2.875 10.00(sw) 80.0 10.00(sw) 80.0 73.0 254 36.3 254 36.3 NA NA 3.000 10.00(sw) 10.00(sw) 10.00(sw) DN65 76.1 254 + 254 + 254 + 3 3.500 10.00(sw) 80.0 10.00(sw) 86.5 NA NA DN80 88.9 254 36.3 254 39.2 4.250 10.00 10.00(sw) 108.0 254 + 254 + NA NA 4 4.500 10.00(sw) 86.7 10.00(sw) 77.0 NA NA DN100 114.3 254 39.3 254 34.9 - 5.250 10.00 130.0 10.00(sw) + NA NA 133.0 254 59.0 254 5.500 10.00(sw) 81.8 10.00(sw) + NA NA DN125 139.7 254 37.1 254 - 5 5.563 10.00(sw) 75.0 10.00(sw) 75.0 NA NA 141.3 254 34.0 254 34.0 6.250 10.00 125.6 10.00(sw) + NA NA 159.0 254 57.0 254 - 6.500 10.00(sw) 10.00(sw) + + NA NA 165.1 254 254 6 6.625 10.00 88.5 10.00(sw) 75.0 NA NA DN150 168.3 254 40.2 254 34.0 8 8.625 10.00 80.0 10.00(sw) 80.0 NA NA DN200 219.1 254 36.3 254 36.3 10 10.750 10.00 123.5 10.00(sw) 84.0 DN250 273.0 254 56.0 254 38.1 NA NA 1 For 14"/DN350 and larger roll grooved systems for carbon steel pipe,Victaulic offers fittings for the Advanced Groove System(AGS).Refer to publication 20.05 for more information.For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. 2 Available with British Standard Pipe Threads,specify"BSP"clearly on order. (sw)=Carbon Steel Segmentally Welded NA=Not Available "+"=Contact Victaulic for details NOTES • All fittings are ductile iron unless otherwise noted with an(sw). • • 07.01 1449 Rev AJ Updated 05/2023 ©2023 Victaulic Company.All rights reserved. victaulic.com 23 Jatauli victaulic.com 4.4 DIMENSIONS (CONTINUED) Reducing Tee No. 25 E.c to E+l c to E-1 No. 29T No. 29F 11,11 IC c 11, 11 to i No.29T No.29F2 1 No.25 Reducing Tee Reducing Tee Grooved Branch Groove x Male Thread2 Groove x Female Thread2 Size Reducing Tee Branch Branch . Approx. Approx. Approx. Weight Weight Weight Nominal Actual Outside Diameter C to E (Each) C to E (Each) C to E (Each) inches inches inches lb inches lb inches lb DN mm mm kg mm kg mm kg 14' r'.x 14 x 4 14.000 . x 14.000 )e 4.500 .11.00(sw) 102.0 11.00(sw) 102.0 . DN350 DN350 DN100 355.6- , 355.6" : 114.3 279. ' 46.3 279 46.3 NA NA 6 6425 11.00(sw) 108.2 11.00(sw) 108.2 NA ` NA DN150 168.3, 279. 49.1 279 49.1 8.625. 1100(sw) 112.0 11.00(sw) 112.0; NA NA MOO 219.1 279 50.8 279 50.8 10 10.750 11.00(sW) 120.0 1.140(sw) 1204 . ,NA NA 0N250 273.11.. 279 54:4 279 54.4 '. ' 12 12.750 11.00(sw) 129.1 1100(sw) 129.1' DN300 , 323.9 279 58.6 279 58:6 NA ,. NA 14.843 14.843 6.500 11.00 142.4 NA NA NA NA 377.0 377.0 165.1 279 64.6 8.625 11.00 145.5 NA NA NA NA 219.1 279 66.0 10.750 11.00 149.9 NA NA NA NA 273.0 279 68.0 12.750 11.00 144.6 NA NA NA NA 323.9 279 65.6 16' x 16 x 4 16 x 16 x 4.500 12.00(sw) 130.0 12.00(siw) 130.0 NA NA DN400 0N400 DN100 0N400 DN400 114.3 305 59.0 305 59.0 6 6425 12.00(sw) 133.5 12.00(sw) 133.5 NA NA DN150 168.3 305 60.6 305 60.6 8 8.625 12.00(sw) 145.0 12.00(sw) . =145.0 " NA NA DN200 219.1 305 65.8 =305 65.8 10 10 750 12.00(sw) 149.5 12.00(sw) 149.5 NA -: NA ' DN250 273.0 305 67.8 • 305 67.8 12 12.750 12.00(sw) 154.0 12.00(sw) 154.0 NA _ NA 0N300 323.9 305 69.9 305 69.9 '. 14 14.000 12.00(sw) ,..'. .167.0 NA NA NA NA DN350 355.6 305 75.7 , 16.772 x 16.772 x 6.250 12.83 189.6 NA NA NA NA 426.0 426.0 159.0 326 86.0 8.625 12.83 213.9 NA NA NA NA 219.1 326 97.0 10.750 12.83 224.9 NA NA NA NA 273.0 326 102.0 _ - 12.750 12.83 224.9 NA NA NA NA 323.9 326 102.0 14.843 12.83 227.1 NA NA NA NA 377.0 326 103.0 ' For 14"/DN350 and larger roll grooved systems for carbon steel pipe,Victaulic offers fittings for the Advanced Groove System(AGS).Refer to public;ation 20.05 for more information.For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. 2 Available with British Standard Pipe Threads,specify"BSP"clearly on order. (sw)=Carbon Steel Segmentally Welded NA=Not Available "+"=Contact Victaulic for details NOTES • All fittings are ductile iron unless otherwise noted with an(sw). 07.01 1449 Rev AJ Updated 05/2023 ®2023 Victaulic Company.All rights reserved. victaulic.com 24 ✓ctaulic victaulic.com 4.4 DIMENSIONS (CONTINUED) Reducing Tee No. 25 -ctoE»I -ctoE.1 No. 29T .. No. 29F WI 119117 to to _7 - No.29T No.29F2 No.25 Reducing Tee Reducing Tee Grooved Branch Groove x Male Thread2 Groove x Female Thread2 Size Reducing Tee Branch Branch Approx. Approx. Approx. Weight Weight Weight Nominal Actual Outside Diameter C to E (Each) C to E (Each) C to E (Each) inches inches inches lb inches lb inches lb DN mm mm kg mm kg mm kg 18' x 18 ; 'x 4 '18 000 ;.:x 18.000 x 4.500 15.50(sw) 194.0 15.50(sw) 194.0 NA. NA DN450. DN450 DN100_;..457.2 ,i '`457.2 114.3 .394 88.0 394 88.0 6 ' .6.625 1539(sw) ' 200.0. 15.50.(sW) : 200.0 NA NA :DN150. 1683- 394 90,7' 394 ' 90.7 8 8.625 15.50(sw) 202.6 15.50(sw) 202.0 DN200 219.1 394 91.9 394 91 ::. 'NA NA 10 10.750 15.50(sw) . 212.0 15.50(sw) r 0N250 273.0 394 96.2 394 NA - NA 12- 12.750 '15.50(sw) - 222.6 _-. 15.50(sw)- DN300 323.9 ' 394 101.0 394 101.0 NA', . NA 14 14.000-15,50(sw) 230:1 ' DN350 $55.6,.y :::,.394 104.4 NA NA NA 16 16 15,,50:(sw) 2.47.E NA NA NA , NA' ' ON400 ON400 394 112.3 18.898 x 18.898 x 4.250 14.75 282.4 NA NA NA NA 480.0 480.0 108.0 375 128.1 5.250 14.75 283.0 NA NA NA NA 133.0 375 128.4 _ 6.250 14.75 283.3 NA NA NA NA 159.0 J- 375 128.5 10.750 14.75 285.1 NA NA NA NA 273.0 375 129.3 14.843 14.75 293.8 NA NA NA NA 377.0 375 133.2 1 For 14'/DN350 and larger roll grooved systems for carbon steel pipe,Victaulic offers fittings for the Advanced Groove System(AGS).Refer to publication 20.05 for more information.For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. 2 Available with British Standard Pipe Threads,specify"BSP"clearly on order. (sw)=Carbon Steel Segmentally Welded NA=Not Available "+"=Contact Victaulic for details NOTES • All fittings are ductile iron unless otherwise noted with an(sw). • • 07.01 1449 Rev AJ Updated 05/2023 ©2023 Victaulic Company.All rights reserved. victaulic.com 25 jctaulie victaulic.com 4.4 DIMENSIONS (CONTINUED) Reducing Tee No. 25 . ctoE-. i ctoE-1 No. 29T No. 29F II1i I IIIi 11, 11 E No.29T No.29F2 No.25 Reducing Tee Reducing Tee Grooved Branch Groove x Male Thread2 Groove x Female Thread2 Size Reducing Tee Branch Branch Approx. Approx. Approx. Weight Weight Weight Nominal Actual Outside Diameter C to E (Each) C to E (Each) C to E (Each) inches inches inches lb inches Ib inches lb DN mm mm kg mm kg mm kg 30', x 20` x 6 20 000 x 30(100 x 6.625 17,25(sw)`: 2d0.0 17.25(sw) 240.0` " NA" NA DN500 DN500 DN 150 "" 508 0 SO$b 16875, b8 3 438 108.9 438' 108 9" 8 8425 17 25(sw) 2440 17.25(sw) NA NA DN200 219.1 438 110.7: 438 110.7": 10 10.750 17•25(sw) ; 17.25(sw). 256.0 0N250 116.1116.1 NA NA 12 12t750 12:35(sw) 4;3 17.25(SW) 2640 DN300 323.9 438 119:9 438 119 7 N+� 14 14.000 .:.17Z"5(sw) 275.0 .. NA NA NA,. NA" ON350. : 355.E 438 124.7 16- 16;000 17:25(3w) 288.6 NA NA NA NA ON400 406A 438 130.9 18 18A00 1.7.25(sw) 297.0 " 0N450 457.2 438 NA NA NA NA: 134.7,: 20.866 x 20.866 x 6.250 17.25 368.2 NA NA NA NA 530.0 530.0 159.0 438 167.0 8.625 17.25 401.3 NA NA NA NA 219.1 438 182.0 10.750 17.25 379.2 NA NA NA NA 273.0 438 172.0 12.750 17.25 401.2 NA NA NA NA 323.9 438 182.0 _.... 14.843 17.25 383.6 NA NA NA NA 377.0 438 174.0 16.772 17.25 401.2 NA NA NA NA 426.0 438 182.0 18.898 17.25 399.2 NA NA NA NA 480.0 438 181.1 For 14"/DN350 and larger roll grooved systems for carbon steel pipe,Victaulic offers fittings for the Advanced Groove System(AGS).Refer to Au licaton 20.05 i. for more information.For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. 2 Available with British Standard Pipe Threads,specify"BSP"clearly on order. (sw)=Carbon Steel Segmentally Welded NA=Not Available =Contact Victaulic for details NOTES • All fittings are ductile iron unless otherwise noted with an(sw). 07.01 1449 Rev AJ Updated 05/2023 ©2023 Victaulic Company.All rights reserved. ' victaulic.com 26 4tauiicr victaulic.com 4.4 DIMENSIONS (CONTINUED) Reducing Tee No. 25 I CtoE+l -CtoE+l No. 29T - - No. 29F 11,11 c "II Tc _toto I No.29T No.29F2 No.25 Reducing Tee Reducing Tee Grooved Branch Groove x Male Thread2 Groove x Female Thread2 Size Reducing Tee Branch Branch Approx. Approx. Approx. Weight Weight Weight Nominal Actual Outside Diameter C to E (Each) C to E (Each) C to E (Each) inches inches inches lb inches lb inches lb DN mm mm kg mm kg mm kg 24',` ;x 24 x 8. 24.000 x 24.000 x : 8b25 20.00(sw) . 340.0 '20.00(sw) 340.0: NA NA` DN600 : DN600 DN200 '..4r09.6" 609.6', . .2.19.1 508 154.2 508 154.2 10 '> 10,750 ;20.00(sw) 343.9 20.00(sw) 343.9 ., - . DN250 273.0 w.:508 156.0 508 ;' 156.0 NA NA ,.. 12 12.750 20.00(sw) 352.8 ..-20.00(sw) 352.8 DN300 323.9 508 160.0 508 160.0 NA(; NA 14 14.000 0.00 +' NA NA NA NA .,; DN350 355.E 508 16 16.000 406A 508 171.5 20.00 NA NA NA NA DN400 18 - 18.000 2fl.t10 � . ..} NA NA NA' NA 20 20.000 20,00(sw) 400.0 NA NA NA NA iDN500` 508.0 508 . - 181.4 24.803 x 24.803 x 6.250 20.00 559.2 NA NA NA NA 630.0 630.0 159.0 508 253.6 8.625 20.00 559.2 NA NA NA NA 219.1 508 253.6 10.750 20.00 562.2 NA NA NA NA 273.0 508 255.0 12.750 20.00 562.2 NA NA NA NA 323.9 508 255.0 - 14.843 20.00 586.4 NA NA NA NA 377.0 508 266.0 16.772 20.00 579.8 NA NA NA NA 426.0 508 263.0 18.898 20.00 568.8 NA NA NA NA 480.0 508 258.0 20.866 20.00 574.3 NA NA NA NA - - 530.0 508 260.5 For AGS fitting information,see publication 20 05 14-60 DN350-DN1500 A Gs- V t For 14"/DN350 and larger roll grooved systems for carbon steel pipe,Victaulic offers fittings for the Advanced Groove System(AGS).Refer to publication 20.05 for more information.For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. 2 Available with British Standard Pipe Threads,specify"BSP"clearly on order. (sw)=Carbon Steel Segmentally Welded NA=Not Available "+"=Contact Victaulic for details NOTES • All fittings are ductile iron unless otherwise noted with an(sw). • 07.01 1449 Rev AJ Updated 05/2023 ©2023 Victaulic Company.All rights reserved. victaulic.com 27 ✓ctaulic' f victaulic.com 4.6 DIMENSIONS 45 Lateral No. 30 7�- c to `` �E ,, c to `,<<, • SE 7 1_iiiilm No.30 Size 45°Lateral Actual Outside Approx.Weight Nominal Diameter C to LE C to SE (Each) inches inches inches inches lb DN mm mm mm kg 1 1.315 5.00(sw) 2.25(sw) 1.7 DN25 33.7 127 57 0.8 11/4 1.660 $75(sw�) 2.50(sw) 25 DN32 42.4 146 b4` 1.1 11/2 1.900 6.25(sw) 2.75(sw) 3.5 DN40 48.3 159 70 1.6 2 . 2.375 7:00(sw) 2 75(sw 5 1 s: 21/2 i 2.875 7.75(sw) 3.00(sw) 9.0 73.0 197 76 4.1 ,1000 50(sw) 3.25(sw) 9.8 3 3.500 8.50 3.25 10.3 DN80 88.9 216 83 4.6 3 Y2 - .4 000 ,:10.00(sw) 7 3:$0(sw) 22.0 AN90 101.6 254 _ 89 - 10.0 4.250 10.50(sw) 3.75(sw) 22.1 108.0 267 95 10.0 DN100 114.3. 267 95 8.1 41/2 5.000 12.50(sw) 4.00(sw) 23.8 127.0 _ 318 _ 102 10.8 - 5.250 12.50(sw) 4.00(sw) 25.3 133.0 318 102 11.5 " 5.500 12.50(sw) 4.00(sw) 26.8 DN125 139.7 318 102 12.1 5 5,563: 12.50(sw) ::: 4.00(sw) 29.8 318 102'. 13.§.' 6.000 14.00(sw) 4.50(sw) 33.8 .,._,__ �_ 152.4 356 114 15.3 " 6.250 14.00(sw) 4.50(sw) 36.8 -w�- - - 1590 _ 356 114 16.7 _ 6.500 14.00(sw) 4.50(sw) 43.6 165.1 356 114 19.8 6 6.625 14.00 450 43.6 DN150 168.3 356 114 19.8".". 1 For 14"/DN350 and larger roll grooved systems for carbon steel pipe,Victaulic offers fittings for the Advanced Groove System(AGS).Refer to piihlication 2005 for more information.For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. (sw)=Carbon Steel Segmentally Welded NOTE • All fittings are ductile iron unless otherwise noted with an(sw). • • 07.01 1449 Rev AJ Updated 05/2023 ©2023 Victaulic Company.All rights reserved. victaulic.com 28 jctaulie victaulic.com 4.6 DIMENSIONS (CONTINUED) 45 Lateral No. 30 LE cto `moo No.30 Size 45°Lateral Actual Outside Approx.Weight Nominal Diameter C to LE C to SE (Each) inches inches inches inches lb DN mm mm kg 8n 8.111111562 ' 18.00(sw) 6.00(sw) " 73.0 0N200" .457 152 33'1 10 10.750 20.50(sw) 6.50(sw) 105.0 DN250 273.0 521 165 47.6 12' 12.75fl 23.00 7(sw) 00(sw) 165.0 DN300 323.9 _ 584 178 748" 14' 14.000 26.50(sw) 7.50(sw) 276.0 DN350 355.6 673 191 125.2 161" 16,000 29.001SW) - 8.00{sw) 3A4.2 406.4 737 DN400 15B.1 .18' 18.000 32.00(sw) 8.50(sw) 429.0 DN450 457.2 813 216 194.6 20' 20.000 35.00(sw) 9.00{sw) " - 500.0 DN51 " , 508.0 8$9::=. 229 226.8 22 22.000 38.00(sw) 9.50(sw) 610.0 DN550 558.8 965 241 276.7 24' 24.000 . 40.00(sw) -10.00(sw) 71 0. - 0N600 609.E 1016 254 3243 For 14"/DN350 and larger roll grooved systems for carbon steel pipe,Victaulic offers fittings for the Advanced Groove System(AGS).Refer to pullication20.05 for more information.For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. (sw)=Carbon Steel Segmentally Welded NOTE • All fittings are ductile iron unless otherwise noted with an(sw). • 07.01 1449 Rev AJ Updated 05/2023 ©2023 Victaulic Company.All rights reserved. victaulic.com 29 ✓ataulic victaulic.com • 4.7 DIMENSIONS 45 Reducing Lateral No. 30-R SWS 7i -i Co % LE i , i li o\<:i' Cto \ L` 5i__ No.30-R SWS 45°Reducing Lateral Size (sw) Approx.Weight Nominal Actual Outside Diameter C to LE C to SE (Each) inches inches inches inches lb DN DN mm mm kg 3 x 3 x 2 3.500 x; ::. 3500" x 2.375 8.50 3.25 9,8 1 DN80 DN80 DN50 88.9 88.9 60.3 216 83 - 4.4 2 h 2.875 8.5t1 .: 3.25 9.8 4 x 4 x 2 4.500 x 4.500 x 2.375 10.50 3.75 10.0 DN100 DN100 DN50 114.3 114.3 60.3 267 95 _ 4.5 2 1 2.875 10.50 3.75 10.0 73.0 267 95 4.5 3 3.500 10.50 3.75 18.3 DN80 88.9 267 95 8.3 5 x 5 ., x , .. 2 5 x : 5: . :.x 2.375 12.50 4.00 ;: 24.0 DN50 60.3 3'18r: :` 1'02 10.9.:: 3 3500 12-S0 4.00 27.0 T DN80 889t..;. 318 102'..: 12.2 4 4.500 12.50 - 4.00 26.5 �__. __ DN700 114.3 318 102 12.0. 6 x 6 x 3 6.625 x 6.625 x 3.500 14.00 4.50 37.0 DN150 DN150 DN80 168.3 168.3 88.9 356 114 16.8 4 4.500 14.00 4.50 36.0 DN100 114.3 356 114 16.3 5 5.563 14.00 4.50 44.7 141.3 356 114 20.3 8 x 8 x 3 8.625 x '.: 8,625 x 3.500 18.00 6.00 58.0 DN200 DN200 0N80 219.1 219.1 88.9 457 152 26.3 4 4500 18.00 6.00 62.0 DN100 .114.3 -' 457 152 28.1 5 5.563 18.00 6.00 75.5 1413 457':.. 152 t.,.: 34.2 6 6.625 18.00 .' 6.00 82.0 , DN150 1683 457 152 37.2 { 10 x 10 x 4 10.750 x 10.750 x 4.500 20.50 6.50 104.8 DN250 DN250 DN100 273.0 273.0 _ 114.3 521 165 47.5 5 5.563 20.50 6.50 105.0 141.3 521 165 47.6 6 6.625 20.50 6.50 105.8 DN150 168.3 521 165 48.0 8 8.625 20.50 6.50 118.0 DN200 219.1 521 165 53.5 12 x 12 x 4 12.750 x` 12.750 x 4.500 23.00 7.00 1350 : DN300 DN300 DN100 323,9 323.9 114.3 584- 178 61.2 5. 5.563 23.00 7.00 122.0 141.3 : 584 1711 55.3 6 6.625 23.00 7.00 137.0 DN150 168.3 584 178 62.1 8 8625 .., 23.00 7.00 147.0 DN200 314:1 584, 178 66.7 10 10.750 ".; 23.00 7,00 167.0 DN250 273,4: 584 178 75.7 For 14'/DN350 and larger roll grooved systems for carbon steel pipe,Victaulic offers fittings for the Advanced Groove System(AGS).Refer to publication 20.05 for more information.For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. (sw)=Carbon Steel Segmentally Welded • • 07.01 1449 Rev AJ Updated 05/2023 ®2023 Victaulic Company.All rights reserved. victaulic.com 30 ✓ataulic r victaulic.com • 4.7 DIMENSIONS (CONTINUED) 45 Reducing Lateral No. 30-R SWS 7. cto i `` LE / \ P Cto \ C �5�- No.30-R SWS 45°Reducing Lateral Size (sw) Approx.Weight Nominal Actual Outside Diameter C to LE C to SE (Each) inches inches inches inches lb DN DN mm mm kg 141 x 14 x 4 14.000 x 14.000 x 4.500 26.50 7.50 176.0 DN350 DN350 DN100 355.6 355.6 114.3 673 191 79.8 6 6.625 26.50 7.50 187.0 DN150 168.3 673 191 84.8 8 8.625 26.50 7.50 210.0 DN200 219.1 673 191 95.3 10 10.750 26.50 7.50 235.0 DN250 273.0 673 191 106.6 12 12.750 26.50 7.50 252.0 DN300 323.9 673 191 114.3 16' ' x 16, x 6., 16.000 x 16.000 x 6.625 29.00 8.00 215.0 DN400 DN400 DN150'; ' 406.4 =: 406.4: 168.3 737 203 `- 97.5 8;" 8b25 29A0 - 8.00 252.5 0N200 219.1 737 ": 203 .. 114;5 10 10.750 29.00 8.00 265.0 DN250 < 273.0 737 -203' 120.2 12 tr " 12.750 29.00 8.00 ..- 295.0 DN300 323.9 737 203 133.8 14 16.000: 29.00 8.00 305.0 t N3Si� 406.4._ 737 203 138.3 181 x 18 x 6 18.000 x 18.000 x 6.625 32.00 8.50 274.0 DN450 DN450 DN150 457.2 457.2 168.3 813 216 124.3 8 8.625 32.00 8.50 275.0 DN200 219.1 813 216 124.7 10 10.750 32.00 8.50 285.0 DN250 273.0 813 216 129.3 12 12.750 32.00 8.50 347.0 DN300 323.9 813 216 157.4 14 14.000 32.00 8.50 350.0 DN350 355.6 813 216 158.8 16 16.000 32.00 8.50 362.0 DN400 _ 406.4 813 216 164.2 j 20' x 20 x 10 20.000 x ' "20.000:: x 10.750 35.00;; 9.00 410.0 ON500 ,t".....0N500 DN250 508.0 508.0. 273.0 889 229 186.0 12 12.750 35.00 9.00 415.0 DN300 323.9 889 229 ; 188.2 14 14.000 35.00 9.00 420.0 0N350 355.6 889 229 190.5 16 ,: 16.000 35.00 9.00 425.0 DN400r 406.4 889 229 192.8 241 x 24 x 16 24.000 x 24.000 x 16.000 40.00 10.00 556.0 DN600 DN600 DN400 _ 609.6 609.6 406.4 1016 254 252.2 20 20.000 40.00 10.00 715.0 DN500 508.0 1016 254 324.3 For AGS fitting information,see publication 20.05 14-60 DN350-DN 1500 AGS ' For 14'/DN350 and larger roll grooved systems for carbon steel pipe,Victaulic offers fittings for the Advanced Groove System(AGS).Refer to puuublicalion 20.05 for more information.For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. (sw)=Carbon Steel Segmentally Welded 07.01 1449 Rev AJ Updated 05/2023 0 2023 Victaulic Company.All rights reserved. victaulic.com 31 jctaulie victaulic.com • 4.8 DIMENSIONS Tee Wye No. 32 IH E, G ..MM. I.-E, No.32 Tee Wye Size _ (sw) Approx.Weight Nominal Actual Outside Diameter G H El E2 (Each) inches inches inches inches inches inches lb DN mm mm mm mm mm kg 2 x 2 x 2 2.375 x.;'"2.375"` x 2.375 '£2.75 7.00 9.00 4.63 6.4 DN50 DN50 131450 603 60.3 . :60.3 70 178 229- 117 2.9 21/2 x 21/2 x 21/2 2.875 x 2.875 x 2.875 3.00 7.75 10.50 5.75 11.5 73.0 73.0 73.0 76 197 267 146 5.2 3 x 3 - x 2 3.500 x 3,500 x 2375 3.25 8.50 10.38 -:;600 12.5 0N80 DN80 DN50` 88.9 88.9 , 60.3< 83 216 264 152 5.7 3 3,500 3.25 8.50 1150 6.50 14.3 DN80'R_ 88.9 -. 83 _ -:216 292 165 : : 6.5 31/2 x 31/ x 31/2 4.000 x 4.000 x 4.000 3.25 10.00 13.00 7.75 15.0 DN90 DN90 DN90 101.6 101.6 101.6 83 254 330 197 6.8 4 x 4 x 1 : 4.500 x 4.500 xx 1.315 3;75 1050 12.25 8.38: 17.0 DN100 : .DN100 0N25;. 114.3 114.3 33,7 95 267 . 311 213 7.7 2: :.. :. 2375. 3.75 10.50,, 11.88 .::. 7.50 20.0 DN50 ` 60.3: 95 267 302 191 9.1 3 3.500 3.75 10.50 12.88 7.88 23.0 DN80 88:9 95 267 327. 200: 10.4 4 4.500 3.7S :. 10.00: 13.63 8.13 26.0 DN100 114.3 95 254 : 346 206 11.8 5 x 5 x 2 5.563 x 5.563 x 2.375 4.00 12.50 13.13 8.75 29.0 DN50 141.3 141.3 60.3 102 318 333 222 13.2 3 3.500 4.00 12.50 14.25 9.25 31.5 DN80 88.9 102 318 362 235 14.3 4 4.500 4.00 12.50 15.13 9.63 36.7 DN100 _ 114.3 102 318 384 244 16.6 5 5.563 4.00 12.50 16.13 10.00 48.0 141.3 102 318 410 254 21.8 6 x 6 ' x 2 6;625 x -6.625- x .2.375 4.50 14.00 - 14.13 9.75 29.0 DN150 DN150 DN50 168.3 168.3 60.3 114 356 359- 248 13.2 3 3.500 4.50 i 14.00 15.31.r; 10.31 37.3 DN80 88.9 114 356 389', 262 16.9 4 4.500 4.50 g 14.00 16.25 10.75 46.3 DN100 114.3 114 356 413 273 21.0 5 5563 4.50 14.00.:- 17.25 11.13 55.0 141.3' 114 ` 35i 438 283 25.0 6 6.625 4.50 14.00 18.25 11.50 60.5 DN150 1683 114 356 464 292 27.4 , 8 x 8 x 2 8.625 x 8.625 x 2.375 6.00 18.00 17.00 12.63 70.0 DN200 DN200 DN50 219.1 219.1 60.3 152 457 432 321 31.8 3 3.500 6.00 18.00 18.19 13.19 76.0 DN80 88.9 152 457 462 335 34.5 4 4.500 6.00 18.00 19.00 13.50 76.4 DN100 114.3 152 457 483 343 34.6 5 5.563 6.00 18.00 20.00 13.88 85.6 141.3 152 457 508 352 38.8 6 6.625 6.00 18.00 21.13 14.38 112.0 DN150 168.3 152 457 537 365 50.8 8 8.625 6.00 18.00 23.25 15.25 127.9 DN200 219.1 152 457 591 387 58.0 (sw)=Carbon Steel Segmentally Welded 07.01 1449 Rev AJ Updated 05/2023 ©2023 Victaulic Company.All rights reserved. victaulic.com 32 ✓ctaulie victaulic.com • 4.8 DIMENSIONS Tee Wye No. 32 E. G j_:aG I E, No.32 Tee Wye Size _ (sw) Approx.Weight Nominal Actual Outside Diameter G H El E2 (Each) inches inches inches inches inches inches lb DN mm mm mm mm mm kg 10 x 10 x 2 10.750 x 10.750 x "'2.375 6.50 2050 18.75 14.38 90.0 • 'DN250 0N250 1JN50 273.0 273.0 60.3 165 521 -' 476 365 ; 40.8 3 3.500 6.50 20.50 -',_ 19.138 14.88 96.0 DN80 88.9 16§, 521 505 378 43.5 4 4.500 6.50 . 2056, `:"". .''' 20.75 15,25 97.4 ::DN100 114.3 �165 521 527 387 44.2 5.' 5 563 6.80 20.50 21.88 15.75 115,0 -:141.3 ;:165 521, 556 400 52.2,,.. 6 6.625 6.50 20.50 22.88 16,13 133.1 0N150. 168.3 165.-. 521;;., 581 410 60.4' 8 8.625- i 50 20 50. �.27.25 19.25. 156.0 ON200 ` 219,1 165 521 692 489 70.8.. 10 '10.750 6.50 20.50 27.25 18.00 ".. 190.0 DN250 _ 273.0 165 521, ; 692 457 86.2 12 x 12 x 2 12.750 x 12.750 x 2.375 7.00 23.00 20.75 16.38 120.0 DN300 DN300 DN50 323.9 323.9 60.3 178 584 -_ 527 416 54.4 3 3.500 7.00 23.00 21.75 16.75 125.0 DN80 88.9 178 584 552 425 56.7 4 4.500 7.00 23.00 22.63 17.13 127.0 DN100 114.3 178 584 _ 575 435 57.6 _ 5 5.563 7.00 23.00 23.63 17.50 143.0 141.3 178 584 600 445 64.9 _- 6 6.625 7.00 23.00 24.78 18.03 165.0 DN150 168.3 _ 178 584 629 458 _ 74.8 8 8.625 7.00 23.00 26.92 18.92 176.0 DN200 219.1 178 584 684 481 79.8 10 10.750 7.00 23.00 29.00 19.75 200.0 DN250 273.0 178 584 737 502 90.7 12 12.750 7.00 23.00 31.00 20.50 240.0 DN300 323.9 178 584 787 521 108.9 (sw)=Carbon Steel Segmentally Welded • • 07.01 1449 Rev AJ Updated 05/2023 ©2023 Victaulic Company.All rights reserved. victaulic.com 33 ✓ctaulic' victaulic.com • • 4.9 DIMENSIONS Adapter Nipple No. 40 -EtoE1 r-EtoE-.I r-EtoE-.1 No. 42 No. 43 _ _ _ _ No.40 No.42 No.43 Adapter Nipple Adapter Nipple Adapter Nipple Groove x Male Thread2 Groove x Bevel Groove x Groove Size (s) (s) (s) Actual Outside Approx.Weight Approx.Weight Approx.Weight Nominal Diameter E to E (Each) E to E (Each) E to E (Each) inches inches inches lb inches lb inches lb DN mm mm kg mm kg mm kg DN20 26.9- -76 0.1. 1 1.315 3.00 0.4 3.00 0.4 3.00 0.4 DN25 33.7 76 0.2 76 -__ 0.2 76 0.2 116 - 1.660 4.00 0.8 4.00' 0.$, 4.00 ' 0.8 DN32 424 '. 102. :' 0.3" ' :102 " _ r 03 102 0.3 1' 1.900 4.00 0.9 4.00 0.9 4.00 0.9 DN40 48.3 102 0.4 102 _ 0.4 102 0.4 2:: ON50" 60.3 102 -0.6„ 102 _ 0.6 102. 0.6 21/2 2.875 4.00 1.9 4.00 1.9 4.00 1.9 73.0 102 0.9 102 0.9 102 0.9 3.000 4.00 2 0 4:00 2,0 4:00 2.0 DN65 76.1 102 - 0.9 102 0.9 102 ,'0,9 3 3.500 4.00 2.5 4.00 2.5 4.00 2.5 DN80 88.9 102 1.1 102 1.1 102 1.1 DN90 101.6 102 1.4 . 102 " 1.4' 102 1.4 ' 4.250 6.00 4.9 6.00 4.9 6.00 4.9 108.0 152 2.2 152 2.2 152 2.2 4 4.500 6.00 . 5.4 6.00 5.4 6.00` 5.4 DN1O0" ".__. 114.3" 152 2.5 : ____u: 152 2.5 152�: 2.5,__"___ 41/2 5.000 6.00 6.3 6.00 6.3 6.00 6.3 1 127.0 152 2.8 152 2.8 152 2.8 ' 5.250 6.00 6.9 - 6.00 6.9 6.00. 6.9 133.0 152 3.1 152 3.1 152 3,1 5.500 6.00 7.2 6.00 7.2 6.00 7.2 DN125 139.7 152 3.3 152 3.3 152 3.3 5 5.563 6.00 7.3 6.00 7.3' 6.00 7.3 141.3 _ 152 3.3 : .'` : :' 152 3.3 .152 3.3 6.000 6.00 8.6 6.00 8.6 6.00 8.6 152.4 152 3.9 152 3.9 152 3.9 6.250 .. 6.00 9.0 6.00 " 9.0 6.00 ' 9.0 159.0 152 4.1 152 4.1 152 4.1 6.500 6.00 9.3 6.00 9.3 6.00 9.3 165.1 152 4.2 152 4.2 152 4.2 6 6.625 6.00 9.5 6.00 9.5 6.00 9.5 0N150 168.3 152 4.3 152 4.3 152 4.3 8 8.625 6.00 14.3 6.00 14.3 6.00 14.3 DN200 219.1 152 6.5 152 _ 6.5 152 6.5 10 10.750, 8.00 . 22.8 8.00 22.8 8.00 22.8� DN250 273.0 203 .._._ 10.3 203 103 '__.. 203 10.3 .. 12 12.750 8.00 33.1 8.00 33.1 8.00 33.1 DN300 323.9 203 15.0 203 15.0 203 1_ -___._ 15.0_ For 14"/DN350 and larger roll grooved systems for carbon steel pipe,Victaulic offers fittings for the Advanced Groove System(AGS).Refer to publication 20.05 for more information.For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. 2 Available with British Standard Pipe Threads,specify"BSP'clearly on order. (s)= Carbon Steel Segmentally Welded NOTE • For pump package nipples with 11/2"/40mm hole cut to receive Style 923 Vic-Let or Style 924 Vic-O-Well request special No.40,42 or 43 nipples and specify No.40-H,42-H or 43-H on order. Note:4-12"/DN100-N300 diameter-8"/200mm length required. • , 07.01 1449 Rev AJ Updated 05/2023 it)2023 Victaulic Company.All rights reserved. victaulic.com 34 4t::iuiiC• • a victaulic.com • • 4.9 DIMENSIONS (CONTINUED) Adapter Nipple No. 40 r--EtoE-1 I.-EtoE-.I r-EtoE-1 No. 42 -:_ No. 43 'r No.40 No.42 No.43 Adapter Nipple Adapter Nipple Adapter Nipple Groove x Male Thread2 Groove x Bevel Groove x Groove Size (s) (s) (s) Actual Outside Approx.Weight 1 Approx.Weight Approx.Weight Nominal Diameter E to E (Each) E to E 1 (Each) E to E (Each) inches inches inches lb inches lb inches lb DN mm mm kg mm kg mm kg 14' 14 0"` 8.00'. : > 36.5 8.00 365 .".r. 8.00''' 36.5 0:N350 `.355.6" 203 16.5. 203 16.5 203 16,5 16' 16.000 8.00 41.8 8.00 41.8 8.00 41.8 DN400 406.4 203 19.0 203 19.0 203 19.0 18', ""' '' 18.000 8.00 _ 47.2 8.00 " 47.2 8.00 47.2 DN450 ".. ,. 457.2 203 21.4 203 21.4 "203 21.4 20' 20.000 8.00 52.5 8.00 52.5 8.00 52.5 DN500 508.0 203 23.8 203 _ 23.8 203 23.8 ,22 __ 22.000" $00. 57.9 ' 8.00 57.9 - 8.00` ,' 57.9 DN550 558.8 203 26.3 ,203 26.3 203' 26,3 _ 24' 24.000 8.00 63.2 8.00 63.2 8.00 63.2 DN600 609.6 203 28.7 203 28.7 203 28.7 14-60 For AGS fitting information,see publication 20.05 DN350-DN1500 AGS. ' For 14"/DN350 and larger roll grooved systems for carbon steel pipe,Victaulic offers fittings for the Advanced Groove System(AGS).Refer to publication 20.05 for more information.For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. 2 Available with British Standard Pipe Threads,specify"BSP'clearly on order. (s)= Carbon Steel Segmentally Welded NOTE • For pump package nipples with 1 1/2"/40mm hole cut to receive Style 923 Vic-Let or Style 924 Vic-O-Well request special No.40,42 or 43 nipples and specify No.40-H,42-H or 43-H on order. Note:4-12"/DN100-N300 diameter-87200mm length required. • • 07.01 1449 Rev AJ Updated 05/2023 ©2023 Victaulic Company.All rights reserved. victaulic.com 35 ✓ataulac' victaulic.com • 4.10 DIMENSIONS Cap No. 60 Bull Plug br 14-E to E No. 61 D No.61 No.60 Bull Plug Size Cap (s) Actual Outside Approx.Weight Approx.Weight Nominal Diameter T (Each) E to E (Each) inches inches inches lb inches lb DN mm mm kg mm kg 1 1.315 0.79 0.2 NA NA DN25 33.7 20 0.1 1' 1.660 0.79 0.4 DN32 . ... 42.4 20 02 NA NA 1 1h 1.900 0.79 0.4 NA NA DN40 48.3 20 0.2 2 2.375 0.8$ 0.7 4.00 2.6 DN50. 60.3 22 0.3 1.0 1.2 21 2.875 0.88 1.2 5.00 3.0 73.0 22 0.5 -- 127 1.4 ' 3.000 0.88 1.2 DN65 76.1 22. 0:5 NA NA 3 3.500 0.88 1.7 6.00 4.5 DN80 88.9 - 22 0.7 152 2.0 3'/z 4 000 0.88 1.9 NA NA 4.250 0.92 2.6 NA NA 108.0 23 1.2 4 4.500 0.92 . 3.1. 7.00 7.5 DN100 i 114.3 23 1.4: _ 178 3.4 41 5.000 1.00(s) 5.4 NA NA 127.0 25 i 2.4 5 250 0.92 .' 3 9" NA :NA 133A 23;.. 1.8 5.500 0.92 4.5 NA NA DN125 139.7 23 2.0 5 5,563 0.92 4.9 8.00 113 141.3 23 2.2 203 "" 5.2 6.250 0.92 5.7 NA NA 159.0 23 2.6 6.500 0.92 6/ NA NA 165.1 23 - 2 8 - 6 6.625 0.92 6.4 10.00 18.0 DN150 168.3 23 2.9 254 { 8.2 200A 216.3 1.13 17.4 NA .. NA 7.9 ! 1 For 14"/DN350 and larger roll grooved systems,Victaulic offers the Advanced Groove System(AGS).For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. (s)=Carbon Steel NA=Not Available "+"=Contact Victaulic for details NOTES • All fittings are ductile iron unless otherwise noted with an(s). • No.60 cap is not suitable for use in vacuum service with Style 72 or Style 750 couplings.No.61 bull plugs should be used. • Steel dish caps available through 24"/DN600,contact Victaulic. • No.61 Bull Plugs should be ued in vacuum service with Style 72 or Style 750 couplings. 07.01 1449 Rev AJ Updated 05/2023 ©2023 Victaulic Company.All rights reserved. victaulic.com 36 ✓ctaulid victaulic.com • 4.10 DIMENSIONS Cap No. 60 in Bull Plug bl- E to E No. 61 No.61 No.60 Bull Plug Size Cap (s) Actual Outside ! Approx.Weight Approx.Weight Nominal Diameter T (Each) E to E (Each) inches inches inches Ib inches lb DN mm mm kg mm kg 8 8:625 1.13 13.6 12.00 "', 29.0 DN200"" 219.1 29 �___ 6.2 305' ._- 13.2 10 10.750 1.13 23.6 10.00 39.0 DN250 273.0 29 10.7 254 17.7 12 12:750 1.25 DN300 323.9 .. 32 17.5 14' 14.000 9.50(s) 42.0 DN350 355.6 241 19.1 NA NA 16 3 16.000 - 10.00(s) 45A NA' NA "`- DN400 406.4 254; 2{iA 18' 18.000 11.00(s) 58.0 DN450 457.2 2.0079(s) 79 26.3 NA NA 201 20.000 1" .00(s) 67S" NA NA" ;" ON500 508.0 305 30b ":. " 22 22.000 13.00(a) + NA NA DN550 558 8 330 24' r DN600 24000_ 13.50.(s). 105A NA 343 -.� _ 47 6 For AGS fitting information,see publication 20.05 DN350-DN1500 AGS i For 14"/DN350 and larger roll grooved systems,Victaulic offers the Advanced Groove (AGS).For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. (s)=Carbon Steel NA=Not Available "+"=Contact Victaulic for details NOTES • All fittings are ductile iron unless otherwise noted with an(s). • No.60 cap is not suitable for use in vacuum service with Style 72 or Style 750 couplings.No.61 bull plugs should be used. • Steel dish caps available through 24/DN600,contact Victaulic. • No.61 Bull Plugs should be ued in vacuum service with Style 72 or Style 750 couplings. • 07.01 1449 Rev AJ Updated 05/2023 ©2023 Victaulic Company.All rights reserved. • ✓ctaul�lc victaulic.com 37 victaulic.com 4.11 DIMENSIONS Flanged Adapter Nipple No. 41 -E to E 1 1.1 _--_- ----------- No.41 ---- No.41-DN ANSI Class 125 Flange PN10/16 Flange Adapter Nipple Adapter Nipple Flat Face Flat Face Size (s) (s) Actual Outside 1 Approx.Weight Approx.Weight Nominal Diameter E to E (Each) E to E (Each) inches inches inches lb inches lb DN mm mm kg mm kg Vo1050 3.00 + NA NA DN20 _ 26.9 76 1 1.315 3.00 2.0 3.00 2.6 DN25 33.7 76 0.9 76 1.2 , DN32" 42.4 11/2 1.900 4.00 3.5 NA NA DN40 48.3 102 1.6 DN50 60.3 102 2:5. - 102 2.8 2'/2 2.875 4.00 8.0 NA NA 73.0 102 3.6 3.000 NA NA 4.00 7.1 DN65 76.1 ` 102 3.2 3 3.500 4.00 9.5 4.00 9.0 DN80 88.9 102 4.3 _ 102 4.1 3' 4,900 4.00 + NA NA DN90 101.6 102 4.250 NA NA NA NA 108.0 4 4.500 6.00 16.7 6.00 12.8 DN 104 � v :114. 152 7.6 152 5.8 41 5.000 NA NA NA ._._._" NA..__.----_--- 127.0 _ 5.250 T., NA ,. NA T NA. NA 133.0 5.500 NA NA 6.00 16.8 DN 125 139.7 152 7.6 5 5.563 6.00 21.5 NA NA 141.3 152 9.8 6.500 NA NA NA NA 165.1 6 6.625 6.00 26.5 6.00 20.5 DN 150 168.3 152 12.0 152 9.3 200A 216.3 NA NA NA NA For 14"/DN350 and larger roll grooved systems,Victaulic offers the Advanced Groove System(AGS). For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. (s)=Carbon Steel NA=Not Available "+"=Contact Victaulic for details • • 07.01 1449 Rev AJ Updated 05/2023 ®2023 Victaulic Company.All rights reserved. victaulic.com 38 ✓ctaulic victaulic.com • • 4.11 DIMENSIONS (CONTINUED) Flanged Adapter Nipple No. 41 .—E`oE— 1111 No.41 No.41-DN ANSI Class 125 Flange PN10/16 Flange Adapter Nipple Adapter Nipple Flat Face Flat Face Size (s) (s) Actual Outside Approx.Weight Approx.Weight Nominal Diameter E to E (Each) E to E (Each) inches inches inches lb inches lb DN . mm mm kg mm kg 8 = 8625 6.00 39,0. 6.00 30.8 DN200 219.1 152. : 17.7 152 1411 250A 267.4 NA NA NA NA 10 10 750' 8.00 641 v 8.00 — 46.3 DN250` - .._ 273.0 203 29.1 v 203 210 300A 318.5 NA NA NA NA __.12— 12150 " :8.00 87.0 8.00 " 58.7 DN300 323.9 :203 39.5 203 26.6 For 14'/DN350 and larger roll grooved systems,Victaulic offers the Advanced Groove System(AGS). For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. (s)=Carbon Steel NA=Not Available "+"=Contact Victaulic for details • • 07.01 1449 Rev AJ Updated 05/2023 ©2023 Victaulic Company.All rights reserved. victaulic.com 39 ✓ctaulic• victaulic.com • 4.11 DIMENSIONS (CONTINUED) Flanged Adapter Nipple No. 45F EtoE> EtoE* No. 45R - L No. 45FE _ _E to E--I _ No.45F No.45R No.45FE ANSI Class 150 Flange Adapter ANSI Class 150 Flange Adapter PN10/16 Flange Size Nipple Flat Face Nipple Raised Face Adapter Nipple Flat Face Actual Outside Approx.Weight Approx.Weight Approx.Weight Nominal Diameter E to E (Each) E to E (Each) E to E (Each) inches inches inches lb inches lb inches lb DN mm mm kg mm kg mm kg V4 " L050 3.00(s)- 2.0 ' 3.00(s) - .2.0 1 1.315 3.00(s) 2.7 3.00(s) 2.7 NA NA DN25 33.7 76 1.2 76 1.2 11 1 1.660 , 4,00(s)= ,, w.°3.6" 4.00(s) ....;. 3.6 " NA NA DN32 42.4 102 ,r =(b 102 _ 1,6 11/2 1.900 4.00(s) 3.9 4.00(s) 3.9 2.52 + DN40 48.3 102 1.8 102 1.8 64 2 " 2 375 4.00 6.0 4.00 6.0 2 52 DN50 60.3 102. 2.7 102 2.7 64 + 21 2.875 4.00 9.9 4.00 9.9 73.0 102 4.5 102 4.5 NA NA DN65 761 NA NA NA NA 64 + 3 3.500 4.00 11.7 4.00 11.7 2.52 DN80 88.9 102 5.3 102 5.3 64 + DN90 101.E 102 6.3 102 6.3" NA NA; 4.250 NA NA NA NA NA NA 108.0 4. 4.500 6.00 183 6.00 185 2.7b DN100 114.3 152" 8.4 152 8.4 70 DN125 139.07 2.76 NA NA NA NA 7� + 5 5.563 6.00(s) 21.4 6.00(s) 21.4" Nfl NA 141.3` 152 9,7 152 9.7 6.5 0 6 NA NA NA NA 2 0 +_. 1 1 6 6.625 - 6.00(s) 29.0. 6.00(s) 29.0 2.76 " 0N150 168.3 _.� 152 13.2. "::' '152 ry'13,2:' 70 8 8.625 6.00(s) 42.0 6.00(s) 42.0 3.15 0.0 DN200 219.1 152 19.1 152 19.1 80 0.0 10 10.750 8.00(s) 64.2 8.00(s) 64.2 " '3.15 .` 0.0 DN250 273.0 203 29.1 '` 203 29.1' 80 '; 0.0 12 12.750 8.00(5) 88.2 8.00(5) 88.2 3.15 0.0 DN300 323.9 203 40.0 203 40.0 80 0.0 14' = 14.000 8.00(s) " _"" 126.4 8.00(s)- 126.4 NA NA DN350 355.6 203 57.3 203 57.3 161 16.000 8.00(s) 150.0 8.00(s) 150.0 NA NA DN400 1 406.4 203 68.0 y- 203 68.0 1 For 14"/DN350 and larger roll grooved systems,Victaulic offers the Advanced Groove System(AGS).For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. (s)=Carbon Steel NA=Not Available "+"=Contact Victaulic for details NOTE • All fittings are ductile iron unless otherwise noted with an(s). • 07.01 1449 Rev AJ Updated 05/2023 ©2023 Victaulic Company.All rights reserved. victaulic.com 40 ✓atauliiC victaulic.com 4.11 DIMENSIONS (CONTINUED) Flanged Adapter Nipple No. 45F •.-EtoE+ EtoE► No. 45R — No. 45FE EtoE -• _ No.45F No.45R No.45FE ANSI Class 150 Flange Adapter ANSI Class 150 Flange Adapter PN1O/16 Flange Size Nipple Flat Face Nipple Raised Face Adapter Nipple Flat Face Actual Outside Approx.Weight Approx.Weight Approx.Weight Nominal Diameter E to E (Each) E to E (Each) E to E (Each) inches inches inches lb inches lb inches lb DN mm mm kg mm kg mm kg 18r 8,t (s) 177.0 8,00(5) 1770 0N450 v> 4 7 .. "; ?3 80.3 20 .. 80.3 NA; NA 20' 20.000 8.00(s) 218.0 8.00(5) 218.0 DN500 508.0 203 98.9 203_ 98.9 NA NA 24° 24 000 8.00(s) 283.0 8.00(s) 283.0 NA NA ON600 609 6 ,r.::<s: _ 203 v �,,128.4 203 — 128.4 For AGS fitting information,see publication 20.05 14-60 DN350-DN1500 AGS- For 14'1DN350 and larger roll grooved systems,Victaulic offers the Advanced Groove (AGS).For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. (s)=Carbon Steel NA=Not Available "+"=Contact Victaulic for details NOTE • All fittings are ductile iron unless otherwise noted with an(s). • • 07.01 1449 Rev AJ Updated 05/2023 ©2023 Victaulic Company.All rights reserved. victaulic.com 41 ✓1taulicr victaulic.com 4.16 DIMENSIONS (CONTINUED) Flange Adapter Nipple No 46F .-E to E l i.-E to E 1 No 46R No.46F No.46R ANSI Class 300 ANSI Class 300 Flange Adapter Nipple Flange Adapter Nipple Flat Face Raised Face Size (s) (s) Actual Outside Approx.Weight Approx.Weight Nominal Diameter E to E (Each) E to E (Each) inches inches inches lb inches lb DN mm mm kg mm kg DN20 1 1.315 3.00 3.9 3.00 3.9 DN25 33.7 76 1.8 76 1.8 1'/•. 1.660": 4.00 4.8 400 4:8 DN37:.. 42.4 102 2:2 1d2 -- 2.2 1' 1.900 4.00 6.9 4.00 6.9 DN40 48.3 102 3.1 102 3.1 DM 60.3 102. ;,: ; '3.7 '102 3.7 ' 21/2 2.875 4.00 11.9 4.00 11.9 73.0 102 5.4 102 5.4 ON80. 3500 4.00 16.5 4:00 111111911111 3 Y2 4.000 4.00 20.1 4.00 20.1 DN90 101.6 102 9.1 102 9.1 DN100 114.3. 152 12.4 152 , w 12A 5 5.563 6.00 35.3 6.00 35.3 141.3 152 16.0 152 16.0 4 6,625 b.00 47.5 4.00 4 ; DN150 168,3 152 215 152 215 8 8.625 6.00 68.0 6.00 68.0 DN200 _ 219.1 152 30.8 152 30.8 10 10.750 8,00 100.8 8.00 100.8 DN250 _ '273.0 203 .;.. 45.7 203 45.7 12 12.750 8.00 148.0 8.00 148.0 DN300 323.9 203 67.1 203 67.1 141 14000 8.00 180.0 NA }'.NA DN350_._ 355.6': 203 81.8 16' 16.000 8.00 237.0 NA NA DN400 406.4 203 107.5 ON450 - , 457.2 203 134:7. ;.. 201 20.000 8.00 + NA NA DN500 508.0 203 22 22 ti00 8.00 DN550 558.8, 203 NA- NA 24' 24.000 8.00 + NA NA DN600 609.6 203 14-60 For AGS fitting information,see publication 20.05 DN350-DN1500 AGS v ' For 14'/DN350 and larger roll grooved systems,Victaulic offers the Advanced Groove System(AGS).For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. (s)=Carbon Steel NA=Not Available +=Contact Victaulic for details • 07.01 1449 Rev AJ Updated 05/2023 ©2023 Victaulic Company.All rights reserved, victaulic.com 42 ✓ctaulic' . . victaulic.com • 4.12 DIMENSIONS Swaged Nipple No. 53 E to E 1 1.---E to E 1 1.-- E to E-. No. 54 No. 55 Eill 11011 01 No.53 No.54 No.55 Swage Nipple Swage Nipple Swage Nipple Groove x Groove Groove x Male Thread' Male Thread"x Groove Size (s) (s) (s) Approx. Approx. Approx. Weight Weight Weight Nominal Actual Outside Diameter E to E (Each) E to E (Each) E to E (Each) inches inches inches lb inches lb inches lb DN mm mm kg mm kg mm kg NA N DN50 ...1 ' -, ' 0N20 603 ' 26.9 165 0,9 NA NA A 1 ' 1.315 6.50 2.0 630 2.0 6.50 2.0 ---'DN25 ' 33.7 165 0.9 165 0.9 165 , 0.9 114 ' , 1.660 6.50 . 2.0 6.50 2.0 6.50„, " 2.0 0N32 42,4 165 0.9 165 0.9 16S 0.9 11/2 1.900 630 2.0 6.50 2,0 '6.50 2.0 % 0N40 _ 48,3 165 ' 0.9 165 0.9 1455 0.9 , 2'/2 x 1 2.875 x 1.315 7.00 3.0 7.00 3.0 7.00 3.0 DN25 73.0 33.7 178 1.4 178 1.4 178 1.4 11/4 1.660 7.00 3.0 7.00 3.0 7.00 3.0 DN32 42.4 178 1.4 178 1.4 178 1.4 11/2 1.900 7.00 3.0 7.00 3.0 7.00 3.0 DN40 48.3 178 1.4 178 1.4 178 1.4 2 2.375 7.00 3.0 7.00 3.0 7.00 3.0 DN50 60.3 178 1.4 178 1.4 178 1.4 x 11/2 3.000 x 1.900 8.00 4.0 NA NA ' NA NA DN65 ,' 0N40 76.1 48.3 203 1.8 2 2.375 8.00 4.0 NA NA NA DNS() - 60.3 , , 203 ' 18 3 x 1 3.500 x 1.315 8.00 4.5 8.00 4.5 8.00 4.5 DN80 DN25 88.9 33.7 203 2.0 203 , 2.0 203 2.0 -r- 11/4 1.660 8.00 4.5 8.00 4.5 I 8.00 4.5 DN32 42.4 203 2.0 203 2.0 203 2.0 r 1 1/2 1.900 8.00 4.5 8.00 4.5 8.00 4.5 DN40 48.3 203 2.0 203 2.0 203 2.0 2 2.375 8.00 4.5 8.00 4.5 8.00 4.5 DN50 60.3 203 2.0 203 2.0 203 2.0 21/2 2.875 8.00 4.5 8.00 4.5 8.00 4.5 73.0 203 2.0 203 2.0 203 2.0 3.000 8.00 4.5 7 8.00 4.5 NA NA DN65 76.1 203 2.0 203 2.0 DN90 0N80" , ' 101.6 88.9 203 3.1 203 3.1 203 3.1 4 x 1 4.500 x 1.315 9.00 I 7.5 9.00 7.5 9.00 7.5 DN100 DN25 114.3 33.7 229 I 3.4 229 3.4 229 3.4 1 Y4 1.660 I 9.00 7.5 9.00 7.5 NA NA DN32 42.4 229 3.4 229 3.4 11/2 1.900 9.00 7.5 9.00 7.5 9.00 7.5 DN40 48.3 229 3.4 229 3.4 229 3.4 _, 2 2.375 9.00 7.5 9.00 7.5 I 9.00 7.5 DN50 60.3 229 3.4 229 3.4 229 3.4 21/2 2.875 9.00 7.5 9.00 I 7.5 I 9.00 7.5 73.0 229 3.4 229 I 3.4 229 3.4 3.000 9.00 7.5 NA NA NA NA DN65 76.1 229 3.4 3 3.500 9.00 7.5 9.00 7.5 9.00 7.5 DN80 88.9 229 3.4 229 3.4 229 3.4 3 y2 4.000 9.00 7.5 9.00 7.5 9.00 7.5 DN90 101.6 229 3.4 229 3.4 229 3.4 1 Available with British Standard Pipe Threads,specify BSP clearly on order. (s)=Carbon Steel NA=Not Available • 07.01 1449 Rev AJ Updated 05/2023 ©2023 Victaulic Company.All rights reserved. victaulic.com 43 jctaulic' • victaulic.com . 4.12 DIMENSIONS Swaged Nipple No. 53 EtoE-� EtoE-I 1-- EtoE No. 54 No. 55 liplj III WI No.53 No.54 No.55 Swage Nipple Swage Nipple Swage Nipple Groove x Groove Groove x Male Thread' Male Threads x Groove Size (s)____-_ i (s)__--_._--- (s) Approx. Approx. Approx. Weight Weight Weight Nominal I Actual Outside Diameter E to E (Each) E to E (Each) E to E (Each) inches inches inches Ib inches lb inches lb DN mm mm kg mm kg mm kg 5563 x 2.375 11.00 115 11.00 " 11.5 11.00 11.5 DN50 141.3 6t13 '" 279 5 2 279 5,2 279 5 2 3 3500 1"1;00 11 5 11.00 11;5 11.00. .- 11.5 DN80 88.9 279 52 .. 279. S 2 4., 4.Stf0 . 11.00 11.5 11.00 11'.5 11.00 11.5, DN100 114.3."; 279...' 5.2 5.2". ' 279 5 2 6 x 1 x 1.315 12.00 17.0 12.00 17.0 12.00 17.0 DN150 DN25 33.7 305 7.7 305 7.7 305 7.7 1% 1.660 12.00 17.0 12.00 17.0 12.00 17.0 DN32 42.4 305 7.7 305 7.7 305 7.7 1 1/2 1.900 12.00 17.2 12.00 17.2 12.00 17.0 DN40 48.3 305 7.8 i 305 7.8 305 7.7 2 2.375 12.00 17.4 12.00 17.4 12.00 17.4 DN50 60.3 305 7.9 305 7.9 305 7.9 21/z 2.875 12.00 17.4 12.00 17.4 12.00 17.4 73.0 305 7.9 305 7.9 305 7.9 3 3.500 12.00 17.4 12.00 17.4 12.00 17.4 DN80 88.9 305 7.9 305 7.9 305 7.9 3'/z 4.000 12.00 17.5 12.00 17.5 DN90 101.6 305 7.9 305 -__ 7.9 NA NA 4 4.500 I 12.00 ( 17.5 12.00 17.5 ' 12.00 17.5 DN100 114.3 305 7.9 305 7.9 305 7.9 41/2 5.000 1 12.00 i 17.5 12.00 17.5 NA NA 127.0 305 j 7.9 305 7.9 5 5.563 12.00 17.5 12.00 17.5 12.00 17.5 141.3 305 7.9 305 7.9 305 7.9 " x 6- 8 625 x 6.625..: 12.00 29.0 12.00 29.0 ' 12.00 29.0 DN200 DN 150 219.1 168.3 305 -__-_ 13.2.' -305 13.2 305 - 13.2__ 1 1 Available with British Standard Pipe Threads,specify BSP clearly on order. (s)=Carbon Steel NA=Not Available • • 07.01 1449 Rev AJ Updated 05/2023 ©2023 Victaulic Company.All rights reserved. victaulic.com 44 ✓ctaulic• victaulic.com • 4.13 DIMENSIONS Female Threaded Adapter No. 80 E to E No.80 Adapter Size Groove x Female Thread' --- ---- --- Actual Outside Approx.Weight Nominal Diameter E to E (Each) inches inches inches lb DN mm mm kg 4 1.050 2.00(s)" 0.6€ "DN20a L 26.9 51.- : :': 0.3 1 1.315 2.08 0.4 DN25 33.7 53 0.2 1 1:. 1.660 2.29 0.6 `''10N32, 42.4 58 0.3 1'h 1.900 2.29 1.0 DN40 48.3 58 0.5 2 2. 75 = 2.50 1.5 DN50 60.3 = 64 0.7 2 Y2 2.875 2.75 1.8 73.0 70 0.8 3.000 2.75 2.2 DN65 76.1 4 70 1.0 3 3.500 2.75 2.8 DN80 88.9 70 1.3 4 4.500 3.25 4.5 DN100 : = 114.3 83 _._ 2.0 Available with British Standard Pipe Threads,specify"BSP"dearly on order. (s)=Carbon Steel NOTE • All fittings are ductile iron unless otherwise noted with an(s). • • 07.01 1449 Rev AJ Updated 05/2023 ©2023 Victaulic Company.All rights reserved. victaulic.com 45 ✓3taulac victaulic.com 4.15 DIMENSIONS Concentric/Eccentric Reducer No. 50 t to E No. 51rc-EtoE-si El Lid No.50 No.51 Size Concentric Reducer Eccentric Reducer Approx.Weight 1 Approx.Weight Nominal Actual Outside Diameter E to E (Each) E to E I (Each) inches inches inches lb inches lb DN mm mm kg mm kg 1 x ; 3J4 ;;: 1.315 x 1.050 8.00(s) +:. 8.00(s) + DN25 DN20 33.7' 26.9 203" 203 11/4 x 3/a 1.660 x 1.050 8.00(s) 1.3 8.00(s) 1.3 DN32 DN20 42.4 26.9 203 0.6 203 0.6 1 1.315 2.50 0.6 8.00(s) 1.4 DN25 33.7 64 0.3 203 0.6 1lh__ x sdi.: 1.900 x 1.050. 8,50.(s) 1.5 i'" 850(s) 1.5 DN40 DN20 48.3 26:9:,, ' 216 0.7; 'r" 216 0.7 1 1.315`" 2.50 0.8 8.50(s) 1.7 DN25 33:7 64 0.4 216 0.8 F. 1 Y+ . ' 1.660 2.50 0.9 8.50(s) 1.8 DN32.. 42.4 64 0.4 216 0.8 2 x 3/4 2.375 x 1.050 2.56 0.8 9.00(s) 2.2 DN50 _ DN20 60.3 26.9 65 0.4 229 1.0 1 1.315 2.50 0.7 9.00(s) 2.3 DN25 33.7 64 0.3 229 1.0 1'/4 1 1/4 2.50 0.8 9.00(s) 2.5 DN32 DN32 64 0.4 229 __ 1.1 1 Y2 1.900 2.50 1.2 3.50 1.1 DN40 48.3 64 0.5 .-_._._ 89 ._.__ 0.5 2'h x 4 2.875 ,x 1 s050 9.50(s) 9.50(s) r...- D1420 73.0 26,9 241 241 1 1345 r 2.50 1.4 9.50(s) 3.4 DN25 317 64 0.6 241 1.5 114 ' 2.50 1.4 3.50 1.3 DN32 DN32 64 0.6 89 0.6 1'h 1.900 2.50 1.4 9.50(sr - -- 3.8 0N40 48.3. 64 0.6 241 1.7 2 2.375 250 1.5 3.50 1.6 DN50 60.3" 64" 0.7 89 0.7 x 1 3.000 x 1.315 2.50 + NA NA DN65 DN25 76.1 33.7 64 1'/4 1.660 2.50 + NA NA DN32 42.4 64 11/2 1.900 2.50 + NA NA DN40 48.3 64 2 2.375 2.50 + NA NA DN50 60.3 64 21/2 2.875 i 2.75(s) + NA NA 73.0 1._..._... 70 1 For 14"/DN350 and larger roll grooved systems,Victaulic offers the Advanced Groove System(AGS).For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. (s)=Carbon Steel NA=Not Available "+"=Contact Victaulic for details NOTES • All fittings are ductile iron unless otherwise noted with an(s). • Available with make threaded small end No.52 • Steel eccentric reducers available through 30"/DN750,contact Victaulic for dimensions. • •07.01 1449 Rev AJ Updated 05/2023 C 2023 Victaulic Company.All rights reserved. victaulic.com 46 ✓ctaulic victaulic.com • •4.15 DIMENSIONS (CONTINUED) Concentric/Eccentric Reducer No. 50 r-toEl No. 51 *-E to E-e 111111 nd No.50 No.51 Size Concentric Reducer Eccentric Reducer Approx.Weight Approx.Weight Nominal Actual Outside Diameter E to E (Each) E to E (Each) inches inches inches lb inches lb DN mm mm kg mm kg 3 :' x 3/4 .'3500 x .' 1.050 9.50(s)"`">" 9.50(s) .x DN80 8.9 DN20 '8 26.9 241 - + 2�4( . . + 1 1.315` 250 18 950(s) DN25 33.7 :' 64 08 24t 2.2 1,660 2.50 1.4 . 9.50(s) 5.0 ON32 42.4 64 ''OA 241 2.3 1% 1.900 2.50 2.0 950(s) ;" 5.1 2 2.375 3.50 : 1:6 3.50 1.9 DN50 21/2 2,875: ' 150 1.7 3.50 n 2.1 31/2 x 3 4.000 x 3.500 2.50 2.1 10.00(s) 7.0 DN90 DN80 101.6 88.9 64 1.0 254 3.2 4 250 x 2.875 3.50 76,1 89 3.500 350,. NA $8.9 89 4 x 1 4.500 x 1.315 3.00 3.0 10.00(s) 6.5 DN100 DN25 114.3 33.7 76 1.4 254 2.9 11/4 1.660 10.00(s) 10.00(s) DN32 42.4 254 + 254 + 1 1/z 1.900 3.00 2.6 10.00(s) 6.9 DN40 48.3 76 1.2 254 3.1 2 2.375 3.00 3.4 4.00 2.9 DN50 60.3 76 1.5 102 1.3 3.000 3.00 3.3 4.00 3.2 DN65 76.1 76 1.5 102 1.4 21/2 2.875 3.00 3.3 4.00 3.1 73.0 76 1.5 102 1.4 3 3.500 3.00 3.2 4.00 3.4 DN80 88.9 76 1.5 102 ( 1.5 31/2 4.000 3.00 3.0 10.00(s) ( 8.1 DN90 101.6 76 1.4 254 3.7 5.250 x 4.250 4,50 133.0 108.0 : 114 + NA NA 1 For 14"/DN350 and larger roll grooved systems,Victaulic offers the Advanced Groove System(AGS).For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. (s)=Carbon Steel NA=Not Available "+"=Contact Victaulic for details NOTES • All fittings are ductile iron unless otherwise noted with an(s). • Available with make threaded small end No.52 • Steel eccentric reducers available through 30"/DN750,contact Victaulic for dimensions. 07.01 1449 Rev AJ Updated 05/2023 ©2023 Victaulic Company.All rights reserved. victaulic.com 47 jctaulic' victaulic.com 4.15 DIMENSIONS Concentric/Eccentric Reducer No. 50 rto E-�Eli t4-E to E No. 51 nEll No.50 No.51 Size Concentric Reducer Eccentric Reducer - - -- - Approx.Weight Approx.Weight Nominal Actual Outside Diameter E to E (Each) E to E (Each) inches inches inches lb inches lb DN mm mm kg mm i kg x 5.500 x 3.000 4.50 4.1 10.00(s) 10.7 DN125 DN65 139.7 76.1 114 1.9 254 4.9 3 3.500 4.50 5.7 NA ' NA DN80 88.9 114 2.6 4 4.500 4.50 5.1 5.00 + DN100 114.3 114 2.3 127 5"; x " 2 5.563 _i. x 2.375 11.00(s), 10.1 11.00(s) ' 1fl.1 DN50 141.3 60.3 279 4.6 279 4.6 1 2Y2 , 2.875 4.00 4.3I. 11.00" 10.8. 73.0 102 2.0 279 4.9 3 3.500 4.00 5.7 1100(s) 11.1 DN80 8.8:9 102 2.6 `279 3! 4.000 : 11.00(s) + 11.00(s) DN90 101;6 279' 279: 4 4500 350 4.3 5:00 5.5 DN100 � 1143 89 2.0 127 2.5 6.250 x 3.500 4.50 + NA NA 159.0 88.9 114 4.250 4.00 + NA NA 108.0 102 4.500 4.00 + NA 1 NA 114.3 102 5.250 4.00 + NA NA _ 133.0 102 .. 6.500 x.. 2.375' 165.1 60,3 102 2.8 3.000 4.00 5.9 10.50(s) 18.1 76.1 102 2.7 292 8.2 88.9 102 2.8_ 140 2.8 4.500 4.00 6.2 5.50 6,8 114.3 102 2.8 140 3.1 �. 5.500 4.00 5.6 5.50 8.0 139.7 102 . . 2.5 i s 140 " 3.6 5.563 4.00 6.4 5.50 7.5 141.3 102 2.9 140 3.4 6.250 4.00 6.6 NA NA 159.0 '102 3.0 J 1 For 14'/DN350 and larger roll grooved systems,Victaulic offers the Advanced Groove System(AGS).For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. (s)=Carbon Steel NA=Not Available "+"=Contact Victaulic for details NOTES • All fittings are ductile iron unless otherwise noted with an(s). • Available with make threaded small end No.52 • Steel eccentric reducers available through 30YDN750,contact Victaulic for dimensions. • • 07.01 1449 Rev AJ Updated 05/2023 ©2023 Victaulic Company.All rights reserved. victaulic.com 48 ✓ataulic victaulic.com • • 4.15 DIMENSIONS Concentric/Eccentric Reducer No. 50 E No. 51 rt°El E t°E 11111[1 11[Thl No.50 No.51 Size Concentric Reducer Eccentric Reducer Approx.Weight Approx.Weight Nominal Actual Outside Diameter E to E (Each) E to E (Each) inches inches inches lb inches lb DN mm mm kg mm kg 6 x 1 6.625 x 1.315 4.00 6.2 11.50(s) + DN150 DN25 168.3 33.7 102 2.8 292 1'h 1.900 11.50(s) 11.50(s) DN40 48.3 292 + 292 + 2 2.375 4.00 6.6 11.50(s) 14.2 DN50 60.3 102 3.0 292 6.4 2'/2 2.875 4.00 6.4 11.50(s) 14.2 73.0 102 2.9 292 6.4 3.000 11.50(s) 11.50(s) DN65 76.1 292 + 292 + 3 3.500 4.00 6.4 5.50 7.4 DN80 88.9 102 2.9 140 3.4 4 4.500 4.00 5.8 5.50 7.8 DN100 114.3 102 2.6 140 3.5 5.500 5.50 8.1 DN125 139.7 NA NA 140 3.7 5 5.563 4.00 6.4 5.50 8.1 141.3 102 2.9 140 3.7 6.500 4.00 - 7.2 11.50(s) + 165.1 102 3.3 _ 292 8.515 x 3.500_.- 5.00 +m NA NA 2163 88.9 127 4,500 5.00 t NA.' NA 114.3" 127 s500 4.50 + . NA NA 139.7 200A x 165A 216.3 x 6.500 5.00 9.5 NA NA 165.1 i 127 4.3 For 14/DN350 and larger roll grooved systems,Victaulic offers the Advanced Groove System(AGS).For pricing and availability of cut groove fittings in this I size,contact your nearest Victaulic sales representative. (s)=Carbon Steel NA=Not Available "+'=Contact Victaulic for details NOTES • All fittings are ductile iron unless otherwise noted with an(s). • Available with make threaded small end No.52 • Steel eccentric reducers available through 307DN750,contact Victaulic for dimensions. • 07.01 1449 Rev AJ Updated 05/2023 ©2023 Victaulic Company.All rights reserved. victaul c.com 49 ✓ctaulic' victaulic.co_m • • 4.15 DIMENSIONS Concentric/Eccentric Reducer No. 50 rto E» No. 51 rs-EtoE s nd No.50 No.51 Size Concentric Reducer Eccentric Reducer Approx.Weight Approx.Weight Nominal Actual Outside Diameter E to E (Each) E to E (Each) inches inches inches lb inches lb DN mm mm kg mm kg 8 x 21 8.025 x 2:875 1,2.00(s) 12.00(s) DN200 ' :2193 3 3.500 5.00 9.3 ,. 12.00(s) 22.0 DN80 . 88.9 127. 4.2 305 10.0 4 250 5.00 , " : 11.5 108.0 127 5:2., NA. NA 4 4.500 5.00 :10.4 6.00 10.5 DN100 114.3 127 4.7 152 4.8 5,500 5.00 11.7 . 12.00(s)' 24:5 DN125 1397 127 5,3: 305 r 11.1 5 5563 ~ 5.00 11.0 1200(9 23.8 1413 ' 127 53" 305 :. 10.8 6250 4.50 11,9;'y.' " 1590 114 5.4 NA 6,500 5.00 12o5 6.00 ; .r `12.8, 6 6.625 .:. 5.00 .11. , 6,00 13.2 DN150 _ 168.3 127 5.4," 152 6.0 " 10 x 4 10.750 x 4.500 6.25 20.1 13.00(s) 33.8 DN250 DN100 273.0 114.3 159 9.1 330 15.3 5.500 NA NA 13.00(s) 35.7 DN125 139.7 330 16.2 5 5.563 13.00(s) 35.8 13.00(s) 35.8 141.3 330 16.2 330 16.2 6.500 6.00 13.00(s) 165.1 152 + 330 + 6 6.625 6.00 22.0 13.00(s) 36.9 DN150 168.3 _ 152 10.0 330 16.7 8 8.625 6.00 23.0 7.00 37.0 DN200 219.1 152 10.4 178 16.8 - 250A x 200A 267.4 x 216.3 600 23.0 NA NA 152 10A 12 x 4 12.750 x 4.500 14.00(s) 48.0 14.00(s) 48.0 DN300 DN100 323.9 114.3 356 21.8 356 21.8 6.500 14.00(s) 14.00(s) 165.1 356 + 356 + 6 6.625 7.00 25.0 14.00(s) 50.2 DN150__...__ 1683 178 11.3 356 22.8 8 8.625 7.00 38.0 14.00(s) 53.5 DN200 219.1 178 17.2 356 24.3 10 10.750 7.00 38.0 14.00(s) 56.5 DN200 273.0 178 17.2 356 25.6 ' For 14"/DN350 and larger roll grooved systems,Victaulic offers the Advanced Groove System(AGS).For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. (s)=Carbon Steel NA=Not Available "+"=Contact Victaulic for details NOTES • All fittings are ductile iron unless otherwise noted with an(s). • Available with make threaded small end No.52 • Steel eccentric reducers available through 30"/DN750,contact Victaulic for dimensions. • 07.01 1449 Rev AJ Updated 05/2023 ©2023 Victaulic Company.All rights reserved. • victaulic.com 50 ✓ctaulic victaulic.com • •4.15 DIMENSIONS Concentric/Eccentric Reducer No. 50 wtoE.1 No. 51 t.--E to E 111/111 T No.50 No.51 Size Concentric Reducer Eccentric Reducer ---- ---------------- Approx.Weight Approx.Weight Nominal Actual Outside Diameter E to E (Each) E to E (Each) inches inches inches lb inches lb DN mm mm kg mm kg 300A , `x.. x" " " 250A 318.5 x 216.3 7.00 38.0 , NA NA . 178 17.2 14' x 6 14.000 x 6.625 13.00 63.1 13.00 77.2 DN350 DN150 355.6 168.3 330 28.6 330 35.0 8 8.625 13.00 72.7 13.00 81.6 DN200 219.1 330 33.0 330 37.0 10.528 13.00 80.5 13.00 88.2 267.4 330 36.5 330 40.0 10 10.750 13.00 80.5 13.00 88.2 DN200 273.0 330 36.5 330 40.0 12.539 13.00 81.6 13.00 90.4 318.5 330 37.0 330 41.0 12 12.750 13.00 81.6 13.00 90.4 DN300 323.9 330 37.0 330 41.0 11, x 8 16.000 x . 8.625 v"14.00 80,5 14.00 99.2' 1:iN400. `' 0N200" 406.4 219.1 356 36.5 356 45.0 250A 267.4 14.00 93.0 356, 42 2 NA NA 10 10.750 . 14.00 93.0 14.00 99.2 0N200 273.0 '356 422 °.,356 45k 12.539 "; 14.00 100.3 14:t)0 103.6. 318.5 356 45.5 356 47.0 12 . 12.750 14.00 100.3 14.00 103.E DN300 323,9 356 45.5 356 47.0 14 14.000 14.00 100.3 14.00 108.0 DN350 355.6 356 45.5 356 49.0' 18' x 10 18.000 x 10.750 15.00 112.4 15.00 125.7 DN450 DN200 457.2 273.0 381 51.0 381 i 57.0 12 12.750 15.00 122.4 15.00 134.5 DN300 323.9 381 55.5 381 61.0 14 14.000 15.00 122.4 15.00 136.7 DN350 355.6 381 55.5 381 62.0 16 16.000 15.00 126.8 15.00 143.3 DN400 406.4 I 381 57.5 381 1 65.0 1 For 14"/DN350 and larger roll grooved systems,Victaulic offers the Advanced Groove System(AGS).For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. (s)=Carbon Steel NA=Not Available "+"=Contact Victaulic for details NOTES • All fittings are ductile iron unless otherwise noted with an(s). • Available with make threaded small end No.52 • Steel eccentric reducers available through 30"/DN750,contact Victaulic for dimensions. • • 07.01 1449 Rev AJ Updated 05/2023 ©2023 Victaulic Company.All rights reserved. victaulic.com 51 ✓ctaulic' victaulic.com 4.15 DIMENSIONS Concentric/Eccentric Reducer No. 50 rto E No. 51 l ,-E to E-s Ell No.50 No.51 Size Concentric Reducer Eccentric Reducer Approx.Weight Approx.Weight Nominal Actual Outside Diameter E to E (Each) E to E (Each) inches inches inches lb inches lb DN mm mm kg mm kg 20' x r,.-30 20.000 x 10.750e 2000 _ 160.0 20:� ,", 172.0 DN500 DN200 '.' 5080 273.0 :: 508`.. '"..;, ° 72.6 :'"508 �s0 300A 318.6. 20.00 "' „,. 162.3 NA IdA" 508 73.6 12 :; 12.750 20.00 162,3 20.00 '',183.0.. ON300 , 323.9 508:" 73.6 508 83A 14 14.000 20.00 ' 177.5-'' : 20.00 191.8 ; DN350 355.E"` 508 $0.5 508 $70 #16 "16.0i00 i.20.00 176.4 20.00 200.6 DN4(1i3,. .. 4. 7+�0�8//�� 80..0 2"'50/8/� 91.0 18.000 .. ',.ti.',''.20.00 205.0 2000 209.4 DN450..;. 4 7 2:",' ".' S08,. 93.0 50#1. 95.0.. 241 x 10 24.000 x 10.750 20.00 222.7 20.00 222.7 DN600 DN200 _ 609.6 273.0 508 101.0 508 _ 101.0 12 12.750 20.00 209.4 20.00 238.1 DN300 323.9 508 95.0 508 108.0 14 14.000 20.00 213.8 20.00 246.9 DN350 355.6 508 97.0 508 112.0 16 16.000 20.00 215.8 20.00 ( 251.3 DN400 406.4 508 97.9 508 [ 114.0 18 18.000 20.00 229.3 20.00 I 244.7 DN450 457.2 508 104.0 508 111.0 20 20.000 20.00 + 20.00 275.6 DN500 508.0 508 508 125.0 14-60 For AGS fitting information,see publication 20.05 DN350-DN1500 AGS" 1 For 14"/DN350 and larger roll grooved systems,Victaulic offers the Advanced Groove System(AGS).For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. (s)=Carbon Steel NA=Not Available "+"=Contact Victaulic for details NOTES • All fittings are ductile iron unless otherwise noted with an(s). • Available with make threaded small end No.52 • Steel eccentric reducers available through 30"/DN750,contact Victaulic for dimensions. 07.01 1449 Rev AJ Updated 05/2023 ®2023 Victaulic Company.All rights reserved. victaulic.com 52 ✓ataulic victaulic.com • •4.16 DIMENSIONS Small Threaded Reducer No. 52 E E No. 52F r-to El r-to E, 111111 No.52 No.52F Concentric Reducer Concentric Reducer Size Groove x Male Thread' Groove x Female BSPT Thread Approx.Weight Approx.Weight Nominal Actual Outside Diameter E to E (Each) E to E (Each) inches inches inches lb inches lb DN mm mm kg mm kg 1 V4 x 1 1.660 .. x 1.315 2.50 O:4 DN32 DN25 42.4 '. ° 33.7 "£; �NA NA . i'64 0.2 11/2 x 1 1.900 x 1.315 2.50 0.8 DN40 DN25 48.3 33.7 64 0.4 NA NA 1'A 1.660 2.50 0.9 NA NA DN32 42.4 64 0.4 2 x V.1 2375 `x 1.050 2.56 0.8 NA NA 01450 DN20 60.3 26.9 '" 65 0.4 DN25 33.7 64 0� NA 'NA 1Y4 1.660 2.50 0.9 NA DN32 42.4 64 0.4 1'!s 1.900 2.50 LO DN40 48.3 64 U.5 . " NA _ NA 2'h x 1 2.875 x 1.315 2.50 1.1 DN25 73.0 33.7 64 0.5 NA NA 1 Y 1.660 2.50 i 1.6 DN32 42.4__ 64 0.7 NA NA 1 1 1.900 2.50 - 1.6 DN40 48.3 64 0.7 NA NA 2 2.375 2.50 1.8 DN50 60.3 64 0.8 NA NA x 1 3A0©. x 1.315 2.50 1.8 DN65 DN25 76.1 33.7 64 ' 08 NA NA 114 1.660" 2".50° 1.8 I D1432 42.4 64 0.8. NA NA 1 h;. 1.900 2.50 1:8 2.50 18 D1440 48.3 64 0.8.. 64 0.8 2.375 2.50 1.8 2.50 2.0 DN50." 60.3 64 0,8 64 0.9 1 Available with British Standard Pipe Threads,specify"BSI,"clearly on order. (s)=Carbon Steel NA=Not Available "+"=Contact Victaulic for details NOTE • All fittings are ductile iron unless otherwise noted with an(s). • 07.01 1449 Rev AJ Updated 05/2023 C 2023 Victaulic Company.All rights reserved. victaulic.com 53 ✓ctaulic victaulic.com • 4.16 DIMENSIONS Small Threaded Reducer No. 52 E E No. 52F iii r-toE El No.52 No.52F Concentric Reducer Concentric Reducer Size Groove x Male Thread1 Groove x Female BSPT Thread Approx.Weight Approx.Weight Nominal Actual Outside Diameter E to E (Each) E to E (Each) inches inches inches lb inches lb DN mm mm kg mm kg 3 x 3/4 3.500 x 1.050 9.50(s) + NA NA DN80 DN25 88.9 26.9 241 1 1.315 2.50 1.8 NA NA DN25 33.7 64 0.8 1'/a 1.660 2.50 1.5 2.50 2.0 DN32 42.4 64 0.7 _ 64 0.9 1' 1.900 2.50 2.2 2.50 2.0 DN40 48.3 64 1.0 64 0.9 2 2.375 2.50 2.0 2.50 2.0 DN50 60.3 _ 64 0.9 64 0.9 21/2 2.875 2.50 2.4 NA NA 73.0 64 1.1 3.000 2.50 2.4 2.50 2.0 DN65 76.1 64 1.1 64 0.9 4.250. �x 1.660 3.00 2.9 148,0" i 42.4 NA NA " 76 t; 1.3 483 1.+900 : 3 00 3.1 3 NA NA: 2.375 :;3.00 1.3 3.00 3.1 61).3 76: 0,6 76 1.4 2.875 3.00 :. 13" 73.0 76I; 0.6 NA NA 3.000 3.00.i" 13 NA NA 76.1 " 76 0.6 3.500 3,50 3.4 NA NA ,88.9• `89 . 1S 4 x 1 4.500 x 1.315 3.00 3.0 DN100 DN25 114.3 33.7 76 1.4 NA NA 11/4 1.660 3.00 3.3 DN32 42.4 NA NA 76 1.5 11/z 1.900 3.00 2.7 3.00 3.3 DN40 48.3 76 1.2 76 1.5 2 2.375 3.00 3.5 3.00 3.5 DN50 60.3 76 1.6 76 1.6 21/2 2.875 3.00 3.5 NA NA 73.0 76 1.6 3.000 3.00 2.9 NA NA DN65 76.1 76 1.3 3 3.500 3.00 3.5 NA NA L DN80 88.9 76 1.6 1 Available with British Standard Pipe Threads,specify"BSP"clearly on order. (s)=Carbon Steel NA=Not Available "+"=Contact Victaulic for details NOTE • All fittings are ductile iron unless otherwise noted with an(s). 07.01 1449 Rev AJ Updated 05/2023 ©2023 Victaulic Company.All rights reserved. victaulic.com 54 ✓ataulic victaulic.com - 4.16 DIMENSIONS Small Threaded Reducer No. 52 E E No. 52F r-to El r-to E-, III El No.52 No.52F 1 Concentric Reducer Concentric Reducer Size Groove x Male Threads Groove x Female BSPT Thread Approx.Weight Approx.Weight Nominal Actual Outside Diameter E to E (Each) E to E (Each) inches inches inches lb inches lb DN mm mm kg mm kg 5.250 x 3 500 4.507 4.6 NA x 5.500 x 3.000 4.50 4.4 NA NA DN125 DN65 139.7 76.1 114 2.0 3 3.500 4.50 4.4 NA NA _ DN80 _ _ 88.9 114 2.0 5 x 2 5.563 , x 2.375 11.00(s). 3.5 NA NA DN50 141.3 60.3 279 1,6 3 3.500 11.00(s) 3.6 NA NA DN80 88.9 . 79. 1.6 4. ..Y 4.500 11.00(s). 11:9:- .., NA f.tr NA % i MOO .:: 114.3 279- 5.4 . 6.250 x 1.660 NA NA 4.50 5.5 159.0 42.4 114 2.5 1.900 NA NA 4.50 5.5 48.3 114 2.5 2.375 W NA NA 4.50 5.5 60.3 _ 114 2.5 3.000 4.50 5.1 NA NA 76.1 114 2.3 3.500 4.75 5.5 NA NA 88.9 121 2.5 6.500 x 1.660 NA`- NA _ 4.00 6.4 . 165.1:. . 42.1 1 ill 2.9 1.900 NA. NA 4AQ 6.6 48.3 03 3.0 2.375 4.00 5.5 4.00 6.6 6i1;3 102; 25 102 3.0 3.000 ° 4.00 76.1 102 3.7. NA. .,, NA 3,500 4.(i0. 6.6 NA NA 88.9 . 102" 3.0 I. Available with British Standard Pipe Threads,specify"BSP"clearly on order. (s)=Carbon Steel NA=Not Available "+"=Contact Victaulic for details NOTE • All fittings are ductile iron unless otherwise noted with an(s). 07.01 1449 Rev AJ Updated 05/2023 ©2023 Victaulic Company.All rights reserved. victaulic.com 55 ✓ataulicr victaulic.com 4.16 DIMENSIONS Small Threaded Reducer No. 52 E E No. 52F o E toEiiI ID No.52 No.52F Concentric Reducer Concentric Reducer Size Groove x Male Thread' Groove x Female BSPT Thread Approx.Weight -� I Approx.Weight Nominal Actual Outside Diameter E to E 1 (Each) E to E (Each) inches inches inches lb inches lb DN mm mm kg mm kg 6 x 1 6.625 x 1.315 4.00 5.5 NA NA DN150 DN25 168.3 33.7 102 2.5 2 2.375 4.00 6.7 NA NA DN50 60.3 102 3.0 21/2 2.875 4.00 5.8 NA NA 73.0 102 2.6 3 3.500 4.00 8.0 NA NA DN80 88.9 102 3.6 4 4.500 11.50(s) 15.9 NA ---NA DN100 114.3 292 7.2 5 5.563 11.50(s) 20.0 NA NA _ 141.3 292 9.1 DN200 DN100 114.3 305 " 10.4 NA - tJA 6" 6.625 12,00(s) 25.0 NA NA s DN150 168.3 3U5" 11.3 1 Available with British Standard Pipe Threads,specify"BSP"clearly on order. (s)=Carbon Steel NA=Not Available "+"=Contact Victaulic for details NOTE • All fittings are ductile iron unless otherwise noted with an(s). • 07.01 1449 Rev AJ Updated 05/2023 ©2023 Victaulic Company.All rights reserved. victaulic.com 56 jctauhc* victaulic.com 4.16 DIMENSIONS (CONTINUED) Hose Nipple No. 48 1.--EtcE--,1 l'IIIIIIIIIIII ------ ----- No.48 Hose Nipple Size (s) Actual Outside Approx.Weight Nominal Diameter E to E (Each) inches inches inches lb � DN mm mm kg 1 ' 1.050; 3,13 ..._-0:3 DN20 26,9.. --- - 1 1.315_��_.._..._ 3.38 0.4 DN25 33.7 86 0.2 . 1' 1.660 3,88 0.6 0N32.. 42.4 9$ 0.3 1 Y2 1.900 3.88 0.8 DN40 48.3 98 0.4 2 2.375 4.50, 1.0 N50 60.3 114:. ' 0,4 2 Y2 2.875 - 5.38 2.0 73.0 137 0.9 3 3.500 5,75 3.1 .45N89 88.9 146 n, 1,4 4 4.500 7.00 4.9 DN100 114.3 178 2.2 5 5.563 8:75 8,0 141.3 222 3.6 6 6.625 10.13 14.3 DN150 168.3 257 6.5 8 r. 8,625 11.88 24.7 014200 219,1 _. ; 302 112 _ I 10 10.750 12.50 41.0 DN250 273.0 318 18.6 12 12.750 14.50 62,0 0N300 �. 323.9 368 281 (s)=Carbon Steel • 07.01 1449 Rev AJ Updated 05/2023 ©2023 Victaulic Company.All rights reserved. victaulic.com 57 ✓ctaulic' victaulic.com • •5.0 PERFORMANCE Flow Data (Frictional Resistance) The chart expresses the frictional resistance of various Victaulic fittings as equivalent feet of straight pipe. Fittings not listed can be estimated from the data given, for example, a 221 "elbow is approximately one-half the resistance of a 45"elbow. Values of mid-sizes can be interpolated. Size 90°Elbows 45°Elbows Tees No.100 No. 110 Actual Outside No.10 1' D No. 11 11/2 D Nominal Diameter Std.Radius Long Radius Std.Radius Long Radius Branch Run inches inches feet inches feet inches feet feet DN mm meters mm meters mm meters meters 44.". 1050° - DN20 1 1.315 1.7 0.8 4.2 1.7 DN25 33.7 0.5 _ 0.2 1.3 0.5 1 V4, 1,660 2:1 1.0 5.3 2.1" 1'h 1.900 2.7 1.3 6.6 2.7 DN40 48.3 0.8 0.4 2.0 0.8 2 2.375 36 : . 2.5 18 -.:; 1.1 8.5 3:6 DN50 ---- 60.3 1.1 3.000 4.3 2.3 _ 10.8 4.3 DN65 76.1 1.3 0.7 3.3 1.3 3" 3500 5.0 38 2.6 1.6 13.0" 5.0 4.250 6.4 _ 3.2 _ 15.3 6.4 108.0 2.0 1.0 4.7 2.0 4 4.500 6.8. 5.0 34 2.1 ' `16.0. " 6.8, DN1.00 114.3 2.1 5.250 8.1 4.1 _ 20.0 8.1 133.0 2.5 1.3 6.1 2.5 5.500 8.5 4.2 210 8.5: DN125 139.7 2.6 13 6.4 2.6 5 5.563 8.5 4.2 21.0 8.5 - 141.3 2.6 1.3 6.4 2.6 6.250 9,4 49 ;::" 250 9.6` 159.0 2.9 1.5 : _ - 7.6 2.9 6.500 9.6 _ 5.0 _ 25.0 110.0 165.1 2.9 1.5 7.6 3.0 6" 6.625 10.0 7.5 5.0 3.0 : :" 25.0 10.0 DN150 168.3 30 23 1 5�-._._.. 0.9 7.6 3.0 8 8.625 13.1 9.8 6.5 4.0 33.1 13.1 DN200 219.1 4.0 3.0 2.0 1.2 10.1 4.0 10 10.750 17.0 . x. . 12.0 8.3 -" 5.0 41.0 17.0 DN250 273.0 5.2 3.7 2.5 "" _N 1.5 12.5 5.2 12 12.750 20.0 14.5 10.0 6.0 50.0 1 20.0 DN300 _ 323.9 6.1 4.4 3.0 1.8 15.2 6.1 14 14.000 24.5' 15.8 18.5' 11.0 70.0 23.0 DN350 355.6 7.5 4.8 5.6 3.4 21.3 7A,:. 16 16.000 28.0' 18.0 21.0' 13.0 80.0 27.0 DN400 406.4 8.5 5.5 6.4 4.0 24.4 8.2 18 18.000 31.0' : 20.0 23.5' 14.0 90.0 304 DN450 457.2 _ 9.4 6.1 7.2 4.3 ,27.4 9.1 20 20.000 34.01 22.5 25.5' 16.0 100.0 i 33.0 DN500 508.0 10.4 6.9 7.8 4.9 30.5 10.1 24 24.000 42.0' 27.0 . ;:29.5'" - -- 19.0 1200 40.0 DN600 609.6 12.8 8.2 '": 9.0 5.8 36.6 12.2 1 Fitting flow data for 14-24/DN350-DN600 size No.10 and No.11 Elbows is based on fittings for Style 07 and Style 77 couplings.For flow data on AGS fittings (No.W10 and No.W11 Elbows),refer to publication 20.05. • 07.01 1449 Rev AJ Updated 05/2023 ©2023 Victaulic Company.All rights reserved. victaulic.com 58 Jctaulic victaulic.com '6.0 NOTIFICATIONS • Read and understand all instructions before attempting to install any Victaulic •,, A 4,11 otproducts. iy • Always verify that the piping system has been completely depressurized and drained immediately prior to installation,removal,adjustment,or maintenance of any Victaulic products. • Confirm that any equipment,branch lines,or sections of piping that may have been isolated for/during testing or due to valve closures/positioning are identified, Q depressurized,and drained immediately prior to installation,removal,adjustment, or maitenance of any Victaulic products. • The installer shall understand the use of this product and why it was specified for the particular application. • The installer shall understand common industry safety standards and potential consequences of improper product installation. • Wear safety glasses,hardhat,and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. • 07.01 1449 Rev AJ Updated 05/2023 ©2023 Victaulic Company.All rights reserved. victaulic.com 59 ✓ctauliC' w victaulic.com • 7.0 REFERENCE MATERIALS Galvanized Plain End Publication 07.01 for Original Groove Fittings Publication 14.04 Publication 20.05 for AGS Fittings '4" . • Extra Heavy EndSeal"ES" Stainless Steel Publication 07.03 Publication 17.16 Fabricated Steel Fittings AGS-Advanced Groove System Publication 07.04 from 14—60"/DN350—DN1500 Publication 20.05 Shouldered Ends Aluminum Publication 07.06 Publication 21.03 xL fittings for abrasive services Copper Publication 07.07 Publication 22.04 110 Ili° Victaulic Base Support Elbows Ductile Iron for AWWA size pipe Publication 07.13 Publication 23.05 • • 07.01 1449 Rev AJ Updated 05/2023 ®2023 Victaulic Company.All rights reserved. victaulic.com 60 jotaulie victaulic.com • • • User Responsibility for Product Selection and Suitability Note Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications.All products Victaulic products for a particular end-use application,in accordance with industry to be installed in accordance with current Victaulic installation/assembly instructions. standards and project specifications,and the applicable building codes and related Victaulic reserves the right to change product specifications,designs and standard regulations as well as Victaulic performance,maintenance,safety,and warning equipment without notice and without incurring obligations. instructions.Nothing in this or any other document,nor any verbal recommendation, Installation advice,or opinion from any Victaulic employee,shall be deemed to alter,vary,supersede, Reference should always be made to the Victaulic installation handbook or installation or waive any provision of Victaulic Company's standard conditions of sale,installation instructions of the product you are installing.Handbooks are included with each shipment guide,or this disclaimer. of Victaulic products,providing complete installation and assembly data,and are available Intellectual Property Rights in PDF format on our website at www.victaulic.com. No statement contained herein concerning a possible or suggested use of any material, Warranty product,service,or design is intended,or should be constructed,to grant any license Refer to the Warranty section of the current Price List or contact Victaulic for details. under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design,or as a recommendation for the use of such Trademarks material,product,service,or design in the infringement of any patent or other intellectual Victaulic and all other Victaulic marks are the trademarks or registered trademarks of property right.The terms"Patented"or"Patent Pending"refer to design or utility patents Victaulic Company,and/or its affiliated entities,in the U.S.and/or other countries. or patent applications for articles and/or methods of use in the United States and/or other countries. • • 07.01 1449 Rev AJ Updated 05/2023 ©2023 Victaulic Company.All rights reserved. victaulic.com 61 jactaullie CARBON STEEL PIPE HOLE CUT PRODUCTS, ,. 1.Q2 ra Mec anical-T`° Bolted Branch Outlets 0i vas pc�B: VNIIPO STYLES 920 AND 920N CE CA Victaulic Mechanical-To Outlet provides a direct branch connection at any location a hole can EN 10311 BS EN 10311 be cut in pipe.The hole is cut oversize to receive a"holefinder" locating collar which secures CPR(EU) CPR(UK) the outlet in position permanently.A pressure responsive gasket seals on the pipe O.D. No,305/2011 2019 No.465 SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS Cross-type connections can be achieved by utilizing two upper housings of the same style and size,with the same or differing branch size connections. NOTE:Style 920 and Style 920N housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded 4 outlet.Specify choice on order. Units are supplied painted with plated bolts.Galvanized hous- ings are available,supplied with plated bolts. i All sizes of Style 920 and 920N are rated at 500 psi/3450 kPa working pressure on Schedule A 10 and 40 carbon steel pipe.They may also be used on high density polyethylene or poly- butylene(HDPE)pipe. Pressure ratings on HDPE are dependent on the pipe rating.Contact Victaulic for ratings on other pipe.Style 920 and 920N are not recommended for use on STYLES 920 AND 920N STYLE 920 CROSS PVC plastic pipe. PATENTED Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 90°angle when permanently attached to the pipeline surface. Additionally,the Vic-Tap II®hole cutting tool,which allows for hole cutting capabilities on pressurized systems,utilizes the Style 920 Mechanical-T in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-T unit.See page 8 for further information. • MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536,grade 65-45-12,with orange enamel coating. Ductile iron conforming to ASTM A-395,grade 65-45-15, is available upon special request. • Optional:Hot dipped galvanized Gasket:(Specify choice*) • Grade"E"EPDM EPDM(Green color code).Temperature range—30°F to+230°F/-34°C to+110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids,oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold+86°F/+30°C and hot+180°F/+82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. • Grade"T"nitrile Nitrile(Orange color code).Temperature range—20°F to+180°F/-29°C to+82°C. Recommended for petroleum products,air with oil vapors,vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over+150°F/+66°C or for hot dry air over+140°F/+60°C. *Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended.Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts:Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.ID2022 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ictaulic° REV P 11.02.1 CARBON STEEL PIPE-HOLE CUT PRODUCTS 11.02 c ical- o Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS Style ,Max.Work i Approx. Size No. Pressure Dimensions Weight Each Run x Branch Hole VS it V 3 Female Nominal Size 920 Diameter T"` Thd. Grv. W Y Z Thd. Grv. Inches or psi a0.13 Inches Inches Inches Inches inches Inches Lbs. Lbs. Y 1.4 Z mm 920N kPa -0.00 mm mm mm mm mm mm kg kg 2 /z(a)❑ I 500 1.50 2.00 2.53 1.61 5.35 2.75 31 ^ _ � 4 50 x 15 920N 3450 41 136 38.1 51 64 70 1.5 �_ ,_ au �� inr 1 �l I(ri 1 3/4(a)❑ 500 1.50 1.97 2.53 161 5.35 2.75 31 _ 20 920N 3450 38.1 50 64 41 136 70 1.5 Ir 1 25Il 500 1.50 1.85 2.53 1.61 136 2.7501.4 yl-1 920N 3450 38.1 47 64 41 136 70 1.4 1^L 1'/4(a)to 920N 500 1.75 2.05 2.75 3.00 ' 1.61 5.35 3.00 3.5 3.2 GROOVED OUTLET 32 3450 44.5 52 70 76 41 136 76 1.7 1.5 1 Yz(a)to 920N 500 1.75 2.03 2.75 3.12 161 5.35 3.25 3.6 3.2 40 , 3450 44.5 52 70 79 41 136 83 1.7 1.5 Y µ Z N 2' Yz(a)9a 920N 500 1.50 2.21 2.74 1.82 5.64 2.75 3.04 655 x 15 3450 38.1 56 70 46 143 70 14 T 3/,(a)§o 920N 500 1 50 2.18 2.74 1 82 5.64 2.75 3 0 V �_ 20 3450 381 55 70 46 143 70 1.4 Aim ll 1(a)5n 920N 500 1.50 2.06 2.74 1.82 5.64 2.75 2.9 i f - -,O-t 25 3450 381 52 70 46 143 70 1.4 y - 1 Y4 t(a)p 920N 500 1.75 2.30 3.00 3.25 1.82 6.29 3.00 3.5 3.2 �,� 32 3450 44.5 58 76 83 46 160 ! 76 1.7 1.5 FEMALE THREADED OUTLET 1 Yz t(a)° 920N 500 2.00 2.28 3.00 3 25 1 82 6.26 3.25 3.6 3.3 40 3450 50.8 58 76 83 46 159 83 1.7 16 76.1 x 1/2(a) 920N 300 1.50 2.22 2.75 2.25 6.46 3.18 3.9 15 2065 , 38.1 56 70 57 164 81 1.8 • Provides a direct branch connection at 4 300 1.50 2.19 2.75 225 6.46 3.18 3.9 any location where a hole can be cut 20((a) 920N 2065 38.1 56 70 57 164 81 1.8 - in the pipe i(a) 920N 300 1.50 2.07 2.75 2.25 6.46 3.18 3.8 _ 25 2065 38.1 53 70 57 164 81 1.7 • A pressure responsive gasket provides 11/4(a)a 920N 500 1.75 2.30 3.00 3.31 1.92 6.29 3.00 3 5 3.2 the seal 32 3450 44.5 58 76 84 49 160 76 1 6 1.5 11/2(a)° 920N 500 2.00 2.28 3.00 3 31 1 92 6.29 3.25 3.5 3.3 • Request Publication 11.03 for 40 3450 50.8 58 76 84 49 160 83 1 6 I 1.5 Mechanical-T cross assemblies 3 1/2(a)o soo 1.502sz 3 os 2.28 6.15 2.75 3.4 80 x 15 920N 3450 38.1 64 78 58 156 70 1.6 • Pressure rated up to 500 psi/3450 kPa 3r.(a)n } 920N 500 1.50 2.49 305 2.28 6.15 2.75 3.4 on steel pipe;also available for use 20 3450 38.1 63 78 58 156 70 1.6 with HDPE pipe I(a) 920N 500 1.50 2.38 3.06 2.28 6.15 2.75 3.3 - 25 3450 38.1 61 78 58 156 70 1.6 • Sizes from 2 x 1 "/50 x 15mm 114(a)toi g20N 500 1.75 2.55 3.25 3.56 2.28 6.15 3.00 3.8 3.7 through 8 x 4"/200 x 100 mm 32(b) 3450 44.5 65 83 90 ! 58 156 76 1.8 1.8 1'/z(a)to 1500 2.00 2.78 3.50 3.56 2.28 6.15 3.25 4.1 3.8 920N 40(b) 3450 50.8 71 89 90 58 156 83 1.9 1.8 2(a).-1, 920N 500 2.50 2.75 3.50 3.56 2.28 6.75 3.88 49 4.6 50 I 3450 63.5 70 89 90 58 172 99 2.3 2.1 3 x 2 920N 500 2.50 3.00 1 375 244 6.72 3.88 I/z 3.8 90 50 j 3450 63.5 76 95 62 171 99 1.8 IMPORTANT NOTES: TABLE CONTINUED ON PG.3 Style 920 and Style 920N housings cannot be **Center of run to engaged pipe end,female threaded outlet only(dimensions approximate). mated to one another t Available with grooved or female threaded outlet.Specify choice on order. to achieve cross connections. t Center of run to end of fitting. It Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT"clearly on order. (b)For 76.1 mm threaded outlet,specify 21/2"BSPT clearly on order. §Vds approved for fire protection services o LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.m 2022 VICTAULIC COMPANY.ALL RIGHTS RESERVED. jctaulic' 11,02 2 REVP ' CARBON STEEL PIPE- HOLE CUT PRODUCTS 11.02 MechanicaL-T® I Branch Outlets STYLES 920 AND 920N DIMENSIONS Style Max.Work Approx. Size No. Pressure@ Dimensions Weight Each Run x Branch Hole V t# V 8 Female Nominal Size 920 Diameter T** Thd. Grv. W Y Z Thd. Gm': Inches or psi +0.13 Inches Inches Inches inches Inches Inches ''Lbs. Lbs. Y > <-Z ►I mm 920N kPa •0.00 -, mm mm : mm mm mm mm kg kg `. 4 I TABLE CONTINUED FROM PAGE 2 4 z(a)❑ 500 1.50 3.03 3.56 2.69 701 2.75 3.7 V 100 x 15 920NI Fill 3450 381 77 90 68 178 70 1.8 '/4(a)0 920N 500 1.50 3 00 3.56 2.69 701 2.75 3.7 _ mW-,4, j 20 , 3450 381 76 90 68 178 70 1.8 o.) y 1(a)0 920N 500 1 50 2.88 3.56 2.69 7.01 2.75 3.6 1 (f 25 3450 38.1 73 90 68 178 70 1.8 GROOVED OUTLET 1'/a(a)to' 920N 500 1.75 3.08 3.78 4.00 E 2.69 701 3.00 4.0 3.6 32(b) i 3450 44.5 78 96 102 68 178 76 1.9 1.8 1'/2(a)taf 920N E 500 2.00 3.28 4.00 4.00 2.69 7.01 3.25 4.2 E 3.9 Y Z� 40(b) 3450 50.8 83 102 102 68 178 83 2.0 1.9 2(a)to 1 920N 500 2.50 3.25 4.00 4.00 2.69 7.01 3.88 5.0 4.6 4 PR50 3450 . 63.5 83 102 102 68 178 99 2.3 21 V T 2'/z(a)t, 500 2.75 2 4 0 2.69 84 418 2.6 2 3 illl�i �� ��a T I(fit t 65 920 3450 69.9 73 102 102 68 186 118 2.6 2 3 1 > ,4 500 2.75 2 88 4.00 2.69 7.34 4.63 6.4 �_111 II 763.1(mm 920 3450 69.9 . 73 102 68 186 118 2 9 V� 3(a)t l 500 3.50 i 3 31 4.50 4.12 2.69 7.73 5.12 8.4 6.4 80 I 920 i 3450 88.9 84 114 105 68 196 130 3.8 2.9 FEMALE THREADED OUTLET - - --_._ 1''A(a)a1 500 175 308 3.78 _ 2.63 764 3.05 5.0 108.0 x 32 920N I 3450 44.5 78 96 67 194 78 2.3 1/(a)a, 920N ' 500 E 200 3.28 E 4.00 _ 2.63 764 3.25 5.0 • Provides a direct branch connection at 40 3450 50.8 83 102 67 194 83 2.3 any location where a hole can be cut 2(a) 920N E 500 2.50 3.25 4.00 2.63 764 4.00 4.0 in the pipe 50 E 3450 63.5 83 102 - 67 194 102 1.9 76.1 mm 920 500 2.75 . 2.88 4.00 4.00 2.63 ; 764 4.29 8.0 7.8 • A pressure responsive gasket provides 3450 699 73 102 102 67 i 194 109 3.6 3.5 the seal 3(a) 1 920 500 3.50 , 3.31 4.50 4.50 2.63 7.63 4.88 6.8 6.5 80 E 3450 88.9 84 114 114 67 194 124 3.1 3.0 • Request Publication 11.03 for 5 1 Yz(a)t 500 200 ! 403 4.75 4.75 3.16 9.70 3.69 7.4 7.6 Mechanical-T cross assemblies 125 x 40 920 E3450 50.8 102 121 121 80 246 94 3.4 3.4 2(a)t 500 2 50 4.00 4.75 4.75 316 9.70 ; 4 38 8.2 8.0 • Pressure rated up to 500 psi/3450 kPa 50 920 3450 E 63.5 102 121 121 80 I 246 111 3 7 3.6 on steel pipe;also available for use 2/(a)t 920 500 2.75 3 63 4.75 4.75 3.16 9.70 463 8.3 79 with HDPE pipe 65 3450 699 92 121 121 80 246 118 3.8 3.6 76.1 mm a 920 500 2 75 3.75 _ 4.75 316 9.70 4.63 8.0 • Sizes from 2 x 1/2"/50 x 15mm ' 3450 699 95 121 80 246 118 3.6 through 8 x 47200 x 100 mm 3(a)t I 920 500 3 50 3.81 5.00 4.63 3.16 970 5.31 8.4 8.8 80 j 3450 88.9 97 127 118 80 246 135 3.8 4.0 2 500 2.50 3.75 4.50 - 3.17 8.00 3.88 8.0 133.0 x 50 1 920N 3450 63.5 95 114 81 203 99 3.6 3 ; 500 350 381 5.00 300 946 5.31 8.0 80 920 3450 88.9 97 127 - 76 240 135 ! 3.6 TABLE CONTINUED ON PG.4 IMPORTANT NOTES: **Center of run to engaged pipe end,female threaded outlet only(dimensions approximate). Style 920 and Style 920N housings cannot be t Available with grooved or female threaded outlet.Specify choice on order. mated to one another # Center of run to end of fitting. to achieve cross connections. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT"clearly on order. (b)For 76.1 mm threaded outlet,specify 21/2"BSPT clearly on order. §Vds approved for fire protection services n LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.e 2022 VICTAULIC COMPANY.ALL RIGHTS RESERVED. IICtauI.0 REV_P 11.02.3 CARBON STEEL PIPE- HOLE CUT PRODUCTS 11.02 • Mechanical- ® Boltedranch Outlets STYLES 920 AND 920N DIMENSIONS Style Max_Work Appro, Size No. Pressure Si' Dimensions Weight Each Run x Branch Hole V t 8 V#, Female Nominal Size 920 Diameter T** TM. Grv. W Y Z Thd. Grv. Inches er psi +0.13 Inches Inches Inches Inches inches Inches Lbs. Lbs. Y > Z->i mm 920N kPa -0.00 mm mm mm mm mm mm kg kg t ^ ^' 1 I TABLE CONTINUED FROM PAGE 3 1'/t 920N j 500 2.00 3.78 4.50 3.30 8.23 3.25 70 V 39.7 x 40 3450 50 8 96 114 84 209 83 3 2 - r`eI�nt rr�Il -- - _ n 2 t 920N 500 2.50 3.75 4.50 3.30 8.23 3.88 90 _ T L-� 50 3450 63.5 95 114 84 209 99 41 6 1'/a(a) j 500 2. 1.75 4.43 5.13 5.13 3.79 915 3.25 51 4.8. I. 150 x 32(b) j 920N 3450 44.5 112 130 130 96 232 83 2.3 2.2 GROOVED OUTLET 1 1/2(a)1ui 920N 500 2.00 4.40 5.13 513 3.79 9.15 3.25 5.4 • 5.1 40(b) I 3450 50.8 112 130 130 96 232 83 2.4 ' 2.3 2(a)to 92ON 500 2.50 4.38 5.13 5.13 3.79 9.15 3.88 60 5.6 SO 3450 63.5 111 130 130 ; 96 232 99 2.7 : 2.5 Y > r--Z 21/2 920 500 2.75 401 513 512 3.69 10.51 4.63 83 7.6 65 3450 69.9 110 130 130 94 267 118 3.8 I 3 4 y di. ---- risk T I PI l 76.1 mm e 920 500 2.75 415 5.21 3.69 10.51 4.63 8.4 3450 69.9 105 132 94 267 118 3.8 i > �� 3(a)t 1 920 500 3.50 431 550 5.13 369 10.51 5.31 99 I 8.4 w 80 3450 88.9 110 140 130 94 267 135 4.5 3.8 y .1�1. 4(a)to 920 500 4.50 3.81 5 75 5.38 3.69 10.51 6.25 101 10.1 100 3450 114.3 97 146 137 94 ! 267 159 4.6 , 4.6 FEMALE THREADED OUTLET 1'/2(a) 500 2.00 4.41 513 363 9.40 3.25 7.8 159.0 x 40 920N 40 3450 50.8 112 130 92 239 83 3.5 2(a) 920N 500 2.50 4.38 5.13 3.63 9.40 3.88 8.0 _ • Provides a direct branch connection at 50 3450 63.5 111 130 92 239 99 36 any location where a hole can be cut 76.1 mm 920 500 2.75 438 5.50 5.13 363 9.40 4.63 9.5 9.5 in the pipe _ 3450 69.9 111 140 130 92 239 118 43 4.3 3 500 3.50 4.31 5.50 5.13 I 3.63 9.40 5.31 8.1 1 14.0 • A pressure responsive gasket provides 80 920 3450 88.9 110 140 130 ' 92 239 135 37 6.4 the seal 108.0mm1 920 500 4.50 4.45 538 3.63 9.40 6.12 10.0 3450 114.3 113 137 92 239 155 4.5 • Request Publication 11.03 for 4 I 920 500 450 3.81 5.75 3.63 9.40 6.25 18.0 Mechanical-T cross assemblies 10o i 3450 114.3 96.80 146 92 239 159 8.2 TABLE CONTINUED ON PG.5 • Pressure rated up to 500 psi/3450 kPa ..Center of run to engaged pipe end,female threaded outlet only(dimensions approximate). on steel pipe;also available for use t Available with grooved or female threaded outlet.Specify choice on order. with HDPE pipe * Center of run to end of fitting. • Sizes from 2 x 1/2°/50 x 15mm # Female threaded outlets are available to NPT and BSPT specifications. through 8 x 4"/200 x 100 mm @ See page 7 for Fire Protection approvals and pressure ratings. (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT"clearly on order. (b)For 76.1 mm threaded outlet,specify 21/2"BSPT clearly on order. §Vds approved for fire protection services ❑LPCB approved for fire protection services IMPORTANT NOTES: 0 Approved for use in China by Tianjin Approvals Company. Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2022 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ICt.'aukc 11.02_4 REVP ' CARBON STEEL PIPE- HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS Style Mar Work Approx. Size No. Pressure@ Dimensions Weight Each Run x Branch Hole V i# VI. female Nominal size 920 .Diameter T** Thd. Gre W Y Z Thd. Gm.' Inches or. psi +0.13 Inches Inches Inches Inches Inches Inches Lbs Lbs. Y a- I Z-s mm 920N kPa -0.00 mm mm mm mm mm mm kg kg a TABLE CONTINUED FROM PAGE 4 1 500 1.50 3.88 4.56 3.79 9.34 2.75 8.0 �. V 8 1651 x 25 920N 3450 381 99 116 96 237 70 3.6 u.r ^ ami I r[11 1/n 920N 500 1.75 443 5.13 _ 379 934 325 8.4 _ ,(, 0, 32 3450 445 113 130 96 237 83 3.8 44Ni...01 W 1 Yz(a)t 920N 500 2.00 441 5.13 513 3.79 9.34 3.25 8.4 54 40 3450 50.8 i 112 130 130 96 237 83 3.8 2.4 GROOVED OUTLET 2(a)t I 920N 500 2.50 4.38 5.13 5.13 3.79 9.34 3.88 8.5 6.0 50 3450 63.5 111 130 130 96 237 99 3.9 2.7 76:1 mm 920 500 2.75 4.01 5.13 5.21 3.63 10.51 4.63 8.6 7.6 3450 69.9 110 130 132 92 ! 267 118 3.9 3.4 Y 1 1 z > 3(a)t e 920 500 3.50 4.31 5.50 5.13 3.63 ' 10.51 5.31 10.2 8.4 A PR 80 ' 3450 88.9 110 140 130 92 267 135 4.6 3.8 V = _ g 4(a)to ' 500 4 50 3.81 5.75 5.38 3.63 10 51 6 25 10.5 8.4 II tl.5. �.. r5r, I I N 1Il 100 920 3450 114.3 97 146 137 92 267 159 4.8 3.8 i 1 >- 'i-t 4 8 2(a)t ( 500 ; 275 5.44 6.19 6.25 481 12.42 4.50 11.6 11.6 W 200 x 50 920 3450 69.9 138 157 159 122 316 114 5.3 5.3 �f y u 2 Yz(a)t 500 2.75 5.07 6.19 6.19 4 81 12 42 4.50 11.6 11.6 65 920 3450 69.9 129 157 157 122 316 114 5.3 I 5.3 FEMALE THREADED OUTLET 761 mm❑ 920 500 2.75 5.25 _ 6.25 4.81 12 42 4.56 _ 11.6 3450 69.9 133 159 122 316 116 5.3 3(a)to 500 3.50 5.31 6.50 6.50 481 1242 5.31 126 11.6 • Provides a direct branch connection at 80 I 920 3450 889 135 165 165 122 316 135 5.7 5.3 any location where a hole can be cut 4(a)to i 500 4.50 4.81 6.75 6.38 481 1242 625 15.3 ` 12.5 in the pipe 100 ! 920 3450 114.3 122 171 , 162 122 316 159 6.9 5.7 **Center of run to engaged pipe end,female threaded outlet only(dimensions approximate). • A pressure responsive gasket provides t Available with grooved or female threaded outlet.Specify choice on order. the seal # Center of run to end of fitting. • Request Publication 11.03 for # Female threaded outlets are available to NPT and BSPT specifications. Mechanical-T cross assemblies @ See page 7 for Fire Protection approvals and pressure ratings.' • Pressure rated up to 500 psi/3450 kPa (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT"clearly on order. On steel pipe; also available for use (b)For 76.1 mm threaded outlet,specify 21/2"BSPT clearly on order. with HDPE pipe §Vds approved for fire protection services ❑LPCB approved for fire protection services • Sizes from 2 x l "/50 x 15mm 0 Approved for use in China by Tianjin Approvals Company. through 8 x 47200 x 100mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to each other to achieve cross connections. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.02022 VICTAULIC COMPANY.ALL RIGHTS RESERVED. liCtSlUliC. REV_._P 11.02.._5 CARBON STEEL PIPE- HOLE CUT PRODUCTS 11.02 echanical- .R Bolted Branch Outlets STYLES 920 AND 920N FLOW DATA Flow test data has shown that the total head loss between point(1)and(2)for the Style 920,920N and 929 Mechanical-Te fittings can best be expressed in terms of the pressure difference across the inlet and branch.The pressure difference can be obtained from the relationship below. zQ Cv and Kv Values Values for flow of water at+60°F/+16°C are shown in the table below. • Formulas for Cv/K.Values: AP = Qz Where: �P = Q2 Where: O /r� z CI Q = C x DP Q=Flow(GPM) K z Q=Flow(m3/hr) AP=Pressure Drop(Bar) ________� /� AP=Pressure Drop(psi) C =Flow Coefficient Q = K x DP Ky=Flow Coefficient Exaggerated for clarity Equivalent Length of Outlet Size Schedule 40 Carbon Steel Pipe (per UL 213,Sec.16) OUTLET SIZE (C=120)t FT C,/K„Values NOMINAL ACTUAL DIAMETER O.D. In/mm In/mm GROOVED THREADED GROOVED THREADED '/a 0.840 11 15 . 213 2 94 34 1.050 ( 16 20 26.7 - 4 13.7 1 1.315 21 25 33.7 3.. 8 1.8 1 A 1.660 50 48 32 42.7 6 42.9 41.1 1'/z 1.900 53 53 11 40 48.3 11 45.4 45.4 2 2.375 112 104 50 603 9 10'h 96 891 21/2 2.875 119 150 65 73.0 20 12 1/2102 128.5 3.000 161 76.1 mm 76.1 16* 138.1 - 3.500 249 237 80 88.9 14 15 1/2 213.4 203.1 4 1 4.500 421 401 100 114.3 20 I 22 360.8 343.6 t Hazen-Williams coefficient of friction is 120. *Pipe with a wall thickness of 0.165in./4.2mm. µ*1"FireLock'C Innovative Groove System(IGS)outlet www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2022 VICTAULIC COMPANY.ALL RIGHTS RESERVED. iCtaul1C 11.02„6 REV P • CARBON STEEL PIPE- HOLE CUT PRODUCT'S 11.02 echanica rBoltedolted Brach Outlets STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies.Contact Victaulic for performance on other pipe and the latest listings and approvals. Approval Agency Run Size Outlet Size Pipe Rated Working Pressures—psi/kPa Actual Nominal Outside Vds Size Diameter Inches/mm Inches/nun Inches/mm Schedule UL ULC FM LPCB (Style 920) (Style 920N) 21/2-6 : 2.875 6.625 All 10,40 400 400 400 290 232 362 65-150 73.0 168 3 2755 2755 2755 1999 1599 2496 21/2-4 2.875 4.500 All DF 300 300 300 290 232 362 65-100 73.0-114.3 2065 2065 2065 1999 1599 2496 21/2-4 i 2.875-4 500 All SF 300 300 300 290 232 362 65-100 ; 73.0-114.3 2065 2065 2065 1999 1599 2496 6 6.625 3 4 10 300 300 250 290 232 362 150 168.3 2065 2065 1724 1999 1599 2496 6 I 6.625 3,4 30,40 300 300 300 290 232 362 150 1683 2065 2065 2065 1999 1599 2496 8 8.625 21/2 10,40 400 _ 145 200 2191 2755 1000 8 j 8.625 3,4 10 300 — 250 _ 145 _ 200 i 219.1 2065 1724 1000 8 8.625 3,4 30,40 300 300 145 200 219.1 2065 2065 1000 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. DF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. VIC-TAP II HOLE CUTTING TOOL FOR The Vic-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical-T unit, 4-87100-200 MM CARBON STEEL PIPE which is a combination of the Style 920 Mechanical-T and Series 726 Vic-Ball Valve.The Vic-Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500 psi/3450 kPa. The Style 931 Vic-Tap II Mechanical-T unit is a full port ball valve which can be mounted on 47100mm, 57125mm,6"/150mm and 8'/200 mm diameter pipe.The Style 931 comes with a 2' 765mm grooved outlet. dC.l€ �l The drill motor is an electric motor with ground fault circuit interrupter(GFCI)in accordance with II .. safety codes. +11 .... For more information,refer to publication 24.01. 1 •• www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2022 VICTAULIC COMPANY.ALL RIGHTS RESERVED. jctaulie REV P 11.02_7 CARBON STEEL PIPE- HOLE CUT PRODUCTS 11.02 , l echanicel-T® Bolted Branch Outlets STYLES 920 AND 920N • INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data,and are available in PDF format on our website at www.victaulic.com. • WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. For complete contact information,visit www.victaulic.com 11.02 1480 REV P UPDATED 07/2022 iCt8UIIC. VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2022 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 11,02._L FireLockTM Outlet T �CtaUIiC Style 922 10.52 • 1.0 PRODUCT DESCRIPTION Available Sizes • 1 1/4—2 1/2'/DN32—DN65 • Threaded Outlet Sizes: 1/2'/DN15, 34a'/DN20, and 1"/DN25 NOTE • IGS Grooved 1YDN25 Outlets available for this product.See publication 10.54. Maximum Working Pressure • 300 psi/2068 kPa/21 Bar Application • Provides a convenient method of incorporating outlets for directly connecting sprinklers, drop nipples,•sprigs, gauges, drains and other outlet products Pipe Material • Carbon steel • Contact Victaulic for use on additional pipe types and wall thicknesses 2.0 CERTIFICATION/LISTINGS ® VdS *OLPCB. C E uK CAMED APPROVED LPS 1186: EN 10311 BS EN 10311 Issue 3.1 CPR(EU) CPR(UK) Cert/LPCB Ref. No.305/2011 2019 No.465 491a/27 NOTES • See Section 7.2 REFERENCE MATERIALS for additional certification information. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION,MAINTENANCE OR SUPPORT. victaulic.com 10.52 3355 Rev L Updated 01/2023 ©2023 Victaulic Company.All rights reserved. 1 ictaulic° victaulic.com 3.0 SPECIFICATIONS - MATERIAL Housing: Ductile iron conforming to ASTM A536, Grade 65-45-12. Ductile iron conforming to ASTM A395, Grade 65-45-15, is available upon special request. Housing Coating: (specify choice) ❑ Orange coating. ❑ Red coating(standard for EMEA-I and Asia Pacific). ❑ Optional: Contact Victaulic with your requirements for other coatings. ❑ Optional: Hot dipped galvanized. Gasket': ❑ Grade"E" EPDM (Type A) EPDM (Violet color code)Applicable for wet and dry(oil-free air)sprinkler services only. Listed/Approved for continuous use in wet and dry systems. Listed/Approved for dry systems at-40°F/-40°C and above. NOT COMPATIBLE FOR USE WITH HOT WATER SERVICES OR STEAM SERVICES. 1 Services listed are General Service Guidelines only.It should be noted that there are services for which these gaskets are not compatible.Reference should always be made to the latest Victaulic Seal Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nuts: ❑ Standard: Carbon steel oval neck track bolts meeting the mechanical property requirements of ASTM A449(imperial) and ISO 898-1 Class 9.8 (metric). Carbon steel hex flange nuts meeting the mechanical property requirements of ASTM A563 Grade B (imperial—hex nuts) and ASTM A563M Class 9 (metric— hex nuts). Track bolts and hex flange nuts are zinc electroplated per ASTM B633 Fe/Zn 5,finish Type III (imperial)or Type II (metric). 10.52 3355 Rev L Updated 01/2023 ©2023 Victaulic Company.All rights reserved. victaulic.com 2 jictaulic° victaulic.com 4.0 DIMENSIONS Style 922 Y 1..11.11 1+ 10 IVr \ ` yTy U" tui Style 922 Size -1 Bolt/Nut Dimensions Weight Nominal Actual 1 Approximate Run x Branch FPT2 Outside Diameter Qty. Size T3 V W Y Z (Each) inches inches inches inches inches inches inches inches lb DN mm mm mm mm mm mm mm kg 11 Ys 1:60 0.840 1.30` 1.83 =c - 1.10 .387 2.56 1 ON32 DN15 , 42.4 x 21.3 1 33 47 . 28: : .:.: 98 44 i' 1.050. 1.28 1.83 1.10'.' 387 2.56:... 'I: DN20 = 26.4" ,. .- 33 47 28 98. 65 0,5 1 = 1315 2 152"°"a 2.18 1.10 3.87 2.56 1 1 Y2 1h 1.900 0.840Egli 1.95 1.22 4.08 2.56 1 40 x DN15 48.3 x 21.3 2 3/e x 13/e 50 31 104 65 0.5_ _ 3/4 1.050 1.40 1.95 1.22 4.08 2.56 1 DN20 26.9 2 3�x 13/8 36 50 31 104 65 0.5 1 1.315 1.64 2.30 1.22 4.08 2.56 1 DN25 33.7 2 3/8 x 1 3/8 42 58 31 104 65 0.6 0 840 1 Ufa 219 t.46. 4.60 2.56 1 50 �. x 0,N15 '':60.3_ x 21.3 5" 2 3/4x 13,b . ,,..42. 56 37: - 117 65 " . 0.6 1.050 1.64 2.19 1".46 4.60 2.56 1 56 37 1l7 65 :6.6 1.46 '.4.60 2.556 = 2 DN25 _ `.33.7 2 1" x134 :: 48 ` 65" 37 117 65 0.7 21 Yz 2.875 0.840 1.91 2.44 1.71 5.40 2.56 2 x DN15 73.0 x 21.3 2 3/8 x 1% 49 62 43 137 65 0.7 3/4 1.050 1.89 2.44 1.71 5.40 2.56 2 DN20 26.9 2 3/3 x 13/8 48 62 43 137 65 0.7 1 1.315 2.13 2.79 1.71 5.40 2.56 2 2 3/8 x 1 3/8 DN25 33.7 54 71 43 137 65 0.7 DN65 " 1 3.000 _._ 0.840 3/e x 13/• 1.91 2.44 1.71 5.50 2.56, 2 X DN15 76.1 x 21,3 2 44 6t' 43 r 140 65..;.. 0.7'. s 1.050 1.89 2.44 1.71 S;S0 2.56 2 DN20 26.9 2" ,%x 13 48 62 43 140 65 07 1 1.315 2.13 : 2.79 1.71 5,50 2.56 2 0N25 33.7 ? 3/s x 1318" 54 71 43 140 65 0.8. 2 Victaulic female threaded products are designed to accommodate standard NPT or BSPT(optional)male pipe threads only.Refer to the specific literature for these types of special male-threaded products for guidance and possible limitations for use.Failure to verify suitability in advance may result in assembly problems or leakage. 3 Center of run to engaged pipe end for NPT threads(dimensions are approximate). • a 10.52 3355 Rev L Updated 01/2023 ©2023 Victaulic Company.All rights reserved. victaulic.com 3 ✓ataulic victaulic.com 5.0 PERFORMANCE Style 922 Equivalent Length of 1 inch Schedule 40 Steel Pipe(per UL 213,Section 16)(C=120)4 Run Size x Outlet Size Threaded Grooved5 inches feet feet DN meters meters 114 18 t2S 1.)N32 " DN25 2.6 1 Y2 1 8.5 12.5 DN40 • DN25 2.6 3.8 2 1 85.. 12.5 ON50 • °,.DN25 2.63.8.xa" 2' 1 8.5 12.5 • DN25 2.6 3.8 1 8-5 125 0N665 x DN25;'„ 2.6 3.8 Hazen-Williams coefficient of friction is 120. 5 1"FireLockTM Innovative Groove System(IGS)outlet 6.0 NOTIFICATIONS i * eQOo0 • Read and understand all instructions before attempting to install, remove,adjust,or maintain any Victaulic piping products. • Depressurize and drain the piping system before attempting to install, remove, adjust, or maintain any Victaulic piping products. • Wear safety glasses, hardhat,and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. 7.0 REFERENCE MATERIALS Dimensions Minimum Hole Diameter/ Maximum Hole Diameter! Hole Saw Size Hole Saw Size inches inches mm mm All Outlet Sizes' i 1 rlo 10.52 3355 Rev L Updated 01/2023 ©2023 Victaulic Company.All rights reserved. victaulic.com 4 ✓ataul�c victaulic.com •7.1 REFERENCE MATERIALS Size Services Pressures per Regulatory Approvals and Listings6 Nominal UL ULC FM T VdS LPCB CNBOP inches psi psi psi psi psi psi DN kPa kPa kPa kPa kPa kPa 114 x? 300 "' 300 :300 : .,;432 ' 232 232 ' " DN32 XDN15 2068', 2068 2068 ;`1600•: - 1600 :1600 1'/4 x 3/4 300 300 300 232 232 232 DN32 X DN20 2068 2068 2068 1600 1600 1600 300 300 232 232 • '" . DN32 X DN23 2068 " - : .."2068 :.. .'_3468 ... i"",'" 1600 1600r:< :"". ".,, 1600 ,. 1 Y x Y 300 300 300 232 232 232 DN40 X DN15 2068 2068 2068 1600 1600 1600 1� x 31i 300"`"_ -. 300' .. • 300 232 232 „„.• 232 DN40 X DN2O 2068; • 2068 „.:,2068. . 1600 .„ . 1600 - 1600 •: 1' x 1 300 --__, 300 300 232 232 232 DN40 X DN25 2068 2068 2068 1600 1600 1600 2 x 1 ' -- • 300 - ' 300 ' 300 ; _ 232 - 232 232 DN50 X DN15 ; 2068 2068 ' 2068 1600 1600" 1600 2 x 3/4 300 300 300 232 232 232 DN50 X 20 2068 2068 2068 1600 1600 1600 2 x 1 ~ • 300 ;300 ; 300 '•.„; 232 232 Z32 `DNSO.X DN25 . 2068"" --2068 '. 2068 " , :,11600•., - 1600 ;: 1600:. . • 2' x1/2 300 300 300 232 232 232 2068 2068 2068 1600 1600 1600 23 x' a :,. 300 - 300 ,. 300 232. ' .232 '232 2068 "2068': '2068"- 1600 '' :1600 - - 1600' 2 Y x 1 300 300 300 232 232 232 2068 2068 2068 1600 1600 1600 _ 300 232 232 232 .. • 0N65 X(MI5 2068 ,.:";1600 16000 • ' ";1600 _ 300 232 232 232 DN65 X DN20 _ 2068 _ 1600 1600 1600 _ 300 232 232 232 DN65 X.DN23 - 2068 1600 1600 1600 j 6 Pressures listed in this chart are based upon standard wall pipe.Approved and Listed pressures may vary by pipe schedule. NOTE • Consult regulatory agency websites for details and the most recent regulatory information. 7.2 REFERENCE MATERIALS 05.01:Vlctaullc Seal Selection Guide 29.01:Victaulic Terms and Conditions of Sale 1-100:Installation Instructions I-922:Installation Instructions FireLockT"'Outlet-I • User Responsibility for Product Selection and Suitability Note Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications.All products Victaulic products for a particular end-use application,in accordance with industry to be installed in accordance with current Victaulic installation/assembly instructions. standards and project specifications,and the applicable building codes and related Victaulic reserves the right to change product specifications,designs and standard regulations as well as Victaulic performance,maintenance,safety,and warning equipment without notice and without incurring obligations. instructions.Nothing in this or any other document,nor any verbal recommendation, Installation advice,or opinion from any Victaulic employee,shall be deemed to alter,vary,supersede, Reference should always be made to the Victaulic installation handbook or installation or waive any provision of Victaulic Company's standard conditions of sale,installation instructions of the product you are installing.Handbooks are included with each shipment guide,or this disclaimer. of Victaulic products,providing complete installation and assembly data,and are available Intellectual Property Rights in PDF format on WeChat. No statement contained herein concerning a possible or suggested use of any material, Warranty product,service,or design is intended,or should be constructed,to grant any license Refer to the Warranty section of the current Price List or contact Victaulic for details. under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design,or as a recommendation for the use of such Trademarks material,product,service,or design in the infringement of any patent or other intellectual Victaulic and all other Victaulic marks are the trademarks or registered trademarks of property right.The terms"Patented"or"Patent Pending"refer to design or utility patents Victaulic Company,and/or its affiliated entities,in the U.S.and/or other countries. or patent applications for articles and/or methods of use in the United States and/or other countries. • '10.52 3355 Rev L Updated 01/2023 ©2023 Victaulic Company.All rights reserved. victaulic.com 5 ✓ataulic Victaulic® FireLockTM Rigid Coupling ✓ctauliC' Style 005H 10.02 IJ■LI • 1► 41•01 Patented Exaggerated for clarity 1.0 PRODUCT DESCRIPTION Available Sizes • 1 —8"/DN32— DN2O0 Maximum Working Pressure • Up to 350 psi/2413 kPa Function • Joins carbon steel pipe with grooved ends conforming to publication25.O1 • This product is designed for fire protection systems only Pipe Material • Schedule 10, Schedule 40 or specialty carbon steel pipe listed in Section 5. For use with alternative materials and wall thicknesses please contact Victaulic • For exceptions reference section 6.0 Notifications 2.0 CERTIFICATION/LISTINGS COus ® VdS LPCBo LISTED 104-1a/02 ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION,MAINTENANCE OR SUPPORT. • victaulic.com 10.02 01538 Rev P Updated 01/2022 ©2022 Victaulic Company.All rights reserved. 1 iCtaulic° victaulic.com 3.0 SPECIFICATIONS- MATERIAL Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Housing Coating: (specify choice) ❑ Orange coating. ❑ Red coating(standard for EMEA-I and Asia Pacific). ❑ Optional: Hot dipped galvanized. Coupling Gasket(specify choice): ❑ Grade "E" EPDM Type A Vic-Plus- Gasket Systems EPDM (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry(oil free air)sprinkler services up to the rated working pressure using the Grade "E" Type A Vic-Plus' Gasket System, requiring no field lubrication for most installation conditions. ❑ Grade "L" silicone Recommended for dry heat, air without hydrocarbons to+350°F and certain chemical service. For dry services,Victaulic continues to recommend the use of Grade "E" Type A FlushSeal®Gasket. Contact Victaulic for details. Standard gasket and FlushSeal gasket approved for dry pipe systems to—40°F/-40°C.Based on"typical"pipe surface conditions,supplemental lubricant is recommended for services installed below 0°F/-18°C and for all dry pipe systems or systems to be subjected to air tests prior to being filled with water. Supplemental lubrication may also be required on pipe with raised or undercut weld seams or pipe that has voids and/or cracks at the weld seams.Victaulic continues to recommend the use of FlushSeal gaskets for dry services. NOTE • Additional gasket styles are available.Contact Victaulic for details. Bolts/Nuts: Carbon steel oval neck track bolt(s) meeting the mechanical property requirements of ASTM A449 (imperial) and ISO 898-1 Class 9.8(M10-M16) Class 8.8(M20 and greater). Carbon steel hex nuts meeting the mechanical property requirements of ASTM A563 Grade B (imperial)and ASTM A563M Class 9 (metric). Track bolts and hex nuts are zinc electroplated per ASTM B633 Fe/Zn 5,finish Type III (imperial) or Type II (metric). • 10.02 01538 Rev P Updated 11/2021 ©2022 Victaulic Company.All rights reserved. victaulic.com 2 ✓ctaulicr victaulic.com • 4 4.0 DIMENSIONS Style 005H Rated for wet and dry sprinkler systems at 350 psi/2413 kPa for 11/4-4732- 100 mm sizes and 300 psi/2068 kPa for 4 1/4-87108-200 mm sizes; Schedule 10 roll grooved or Schedule 40 cut or roll grooved steel pipe. Style 005H is rigid and does not accommodate expansion, contraction or angular deflection. < Y 1 i.i_Z_ii Aso.*iieu I i-A-11/4 Oil la fe IT / Style 005H Size ; Dimensions Actual Maximum Maximum Allow. Approx. Outside Working End Pipe End Weight Nominal Diameter Pressure 14 Load' Separation2 Bolt/Nut3 X Y Z Each inches inches psi Ibs inches No-size inches inches inches lbs mm mm kPa N mm inches mm mm mm kg 1�a ' 1.660 350 755 fl115 2 % .2,1l;.,,,, 2.75 4.50 148 1.2 .32 = =i';: ::42.A . 2413 1'/a 1.900 350 990 0.05 3.00 4.75 1.88 1.2 40 48.3 2413 _ 4415 1.2 2-3/s x 2'/a 76 121 48 0.5 2 2.375 . ,,350 1550 0.07 3S0 5.25 1.88 1.6 2 41. ,21h :. 50 60.3: 2413 6900 1.7 89 133 48 0.7 21/2 2.875 350 2270 0.07 4.00 5.75 1.88 1.9 65 73.0 2413 10110 1.7 2-;/s x 21/2 102 146 48 .09 3.000 :w350 2475 0.07 '°: '- 4.13 5.75 1.88 1.9 76,1mm2-%x2� 76.1 : 2413 .1101fl 1.7 105 146 48 0.9 3 3.500 350 3365 0.07 4.63 6.13 1.88 2.1 80 88.9 2413 14985 1.7 2 1/2 x 2 Y: 118 156 48 1.0 4 4.500 350 5565 0.16 5.75- 7,25 2.13 3,1. 2-34x2Y2 , 100 114.3 . ; 2413 24770 4.1 146. 184 54 1.4 4.250 300 4255 0.16 5.63 7.25 2.13 3.1 108.0 mm 108.0 2068 18940 4.1 2 3/s x 2 Yz 143 184 54 1.4 T 5 5.563 300. 7290 0.16 _.. : " 4.88 9.00 2.13 4.5 125 141.3 ,..:=2068 32445 4.1 2 x 3 175 : 229 54 2.0 5.250 300 6495 0.16 6.63 9.00 2.13 4.5 133.0mm _133.0 2068 28900 4.1 2 Yz x 2;/a 168 229 54 2.0 5.500' 300 7125 0.16 628 9.00 2.13 .4.$ 139.7mm 2-16x21 139.7 __;',2068 31715 4.1 _ 175 229 54 2 2 6 6.625 300 10340 0.16 8.00 10.00 2.13 5.0 150 168.3 2068 46020 4.1 2 ,1/2 x 3 203 254 53 2.3 159.O m, 6.250 300 9200 016 2_%x 2% 7.63, ' 10.00 213 SS „.:.159.0 2068 40955 4r1, 194, 254 6.500 300 9955 0.16 8.15 10.00 2.13 5.5 165.1 mm 165.1 2068 44295 4.1 2 1/2 x 3 207 254 54 2.5 8 8.625 300 17525 0.19 10.50 13.14: ' 2.63 11.3 i 200 219.1 2068 78000 4.8 2-5/a x 43/4 267 334 67 5.1 I 1 Working Pressure and End Load are total,from all internal and external loads,based on standard weight(ANSI)steel pipe,standard roll or cut grooved in accordance with Victaulic specifications.Contact Victaulic for performance on other pipe.WARNING:FOR ONE TIME FIELD TEST ONLY,the Maximum Joint Working Pressure may be increased to 11/2 times the figures shown. 2 The allowable pipe separation dimension shown is for system layout purposes only.Style 005H couplings are considered rigid connections and will not accommodate expansion or contraction of the piping system. 3 Number of bolts required equals number of housing segments.Metric thread size bolts are available(color coded gold)for all coupling sizes upon request. Contact Victaulic for details. 4 Style 005H couplings are VdS and LPC Approved to 16 Bar/235 psi. 10.02 01538 Rev P Updated 11/2021 ©2022 Victaulic Company.All rights reserved. victaulic.com 3 ✓ctaulic' victaulic.com 5.0 PERFORMANCE • Style 005H The information provided below is based on the latest listing and approval data at the time of publication. Listings/ Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Related Working Pressure Related Working Pressure Related Working Pressure psi psi psi Size Size Size Pipe Sch. inches UL ULC FM Pipe Sch. inches UL ULC FM Pipe Sch. inches UL ULC FM 5' 1114-3 - 175 175 175 ,: 11/-2 300 : N/A N/A' Mr, . ''1114-2. 300 :" N/A. N/A 10,40 11/4-3 350 350 350 ET 11/4-2 300 N/A N/A STF 11/4-4 N/A N/A 300 5-8 300 300 300 EZ 4-6 3006 N/A 300 Steady Thd. 11/4-2 N/A N/A 300 BLT 134-2 - 300 300 N/A FF 114-4 N/A N/A 300 TF 3-8 N/A N/A 300 DF 11/4-4 300 300 300 GAL-7 13/4-2 300 N/A N/A WLS 1 Y4-2 300 300 N/A DT :':1/-2 300 300 N/A MLT 114-2' ;300 N/A.. N/A XL 11 -3., 300 300 . 300 EF 11/4-4 1757 N/A 175 MF 11/4-4 300 N/A 3005 5 FM approved for service in 112-4"pipe. 6 UL Listed for service up to 4"pipe only. UL Listed for service up to 3"only. • 4 10.02 01538 Rev P Updated 11/2021 ©2022 Victaulic Company.All rights reserved. victaulic.com 4 ✓ctaulic victaulic.com • 6.0 NOTIFICATIONS • Read and understand all instructions before attempting to install any Victaulic •�� products. Woo ct • Always verify that the piping system has been completely depressurized and drained immediately prior to installation,removal,adjustment,or maintenance of any Victaulic products. • Wear safety glasses,hardhat,and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. • These products shall be used only in fire protection systems that are designed and installed in accordance with current,applicable National Fire Protection Association(NFPA 13, 13D, 13R,etc.)standards,or equivalent standards,and in accordance with applicable building and fire codes.These standards and codes contain important information regarding protection of systems from freezing temperatures,corrosion,mechanical damage,etc. • The installer shall understand the use of this product and why it was specified for the particular application. • The installer shall understand common industry safety standards and potential consequences of improper product installation. • It is the system designer's responsibility to verify suitability of materials for use with the intended fluid media within the piping system and external environment. • The material specifier shall evaluate the effect of chemical composition,pH level,operating temperature,chloride level,oxygen level, and flow rate on materials to confirm system life will be acceptable for the intended service. Failure to follow installation requirements and local and national codes and standards could compromise system integrity or cause system failure,resulting in death or serious personal injury and property damage. NOTICE • Victaulic does not recommend the use of any furnace butt-welded pipe with sizes 2"/DN50 and smaller Victaulic gasketed joint products. This includes, but is not limited to, ASTM A53 Type F pipe. 7.0 REFERENCE MATERIALS 10.01 Victaulic Products for Fire Protection Piping Systems_ReguIatory Approval Reference Guide 1-100 Victaulic Field Installation Handbook • • User Responsibility for Product Selection and Suitability Note Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications.All products Victaulic products for a particular end-use application,in accordance with industry to be installed in accordance with current Victaulic installation/assembly instructions. standards and project specifications,and the applicable building codes and related Victaulic reserves the right to change product specifications,designs and standard regulations as well as Victaulic performance,maintenance,safety,and warning equipment without notice and without incurring obligations. instructions.Nothing in this or any other document,nor any verbal recommendation, Installation advice,or opinion from any Victaulic employee,shall be deemed to alter,vary,supersede, Reference should always be made to the Victaulic install,,ticn handbook or installation or waive any provision of Victaulic Company's standard conditions of sale,installation instructions of the product you are installing.Handbooks are included with each shipment guide,or this disclaimer. of Victaulic products,providing complete installation and assembly data,and are available Intellectual Property Rights in PDF format on WeChat. No statement contained herein concerning a possible or suggested use of any material, Warranty product,service,or design is intended,or should be constructed,to grant any license Refer to the Warranty section of the current Price List or contact Victaulic for details. under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design,or as a recommendation for the use of such Trademarks material,product,service,or design in the infringement of any patent or other intellectual Victaulic and all other Victaulic marks are the trademarks or registered trademarks of property right.The terms"Patented"or"Patent Pending"refer to design or utility patents Victaulic Company,and/or its affiliated entities,in the U.S.and/or other countries. or patent applications for articles and/or methods of use in the United States and/or other countries. • • 10.02 01538 Rev P Updated 11/2021 ©2022 Victaulic Company.All rights reserved. victaulic.com 5 jottaulic* 45° ELBOW )64114311114 14tC—PF/FIWIL lk Cast Iron Class 125 Fittings MATERIAL SPECIFICATIONS Cast iron threaded fittings are UL& ULC Listed and FM Approved. a"' Cast iron per ASTM A126. Dimensions conform to ANSI B 16.4 Class 125. Threads are NPT per ANSI/ASME B 1,20,1, MID APPROVED Fors "andnaWadsend Nat ow at drandandandi DM1 or maw.n Mat swnd.. 45 ELBOW Nominal Size Moe,Working Dim Approx. Pressures A B Wi,Inch Qv le,ovu ;stow An) it term 116.14) �, 1 300 1.12 1,12 0,84 Ph 300 1.29 1.29 1.A0 4 s.."s� Ji r IN) 2, 34f tiX4 .Ii 300 143 14 1 40 ,T.:', ,7:srt' ea3.. 082 2 300 1.68 1.68 2.79 LF 20'5 ff"..,te 4,.r,:'s J:_, ♦-%Wag Nouns Rulings ono for relor�onc�o"�only and based on Soh 40 ppc,For use WED UVUIC,and v FM Immure rdmgs'mws Opt scrredulc,p6oso vit onvilord corn or 4:or4oci your Iota Arn4 Roonoorootivo. 90' ELBOW ( P4JWfl siww : Cast Iron - Class 125 Fittings MATERIAL SPECIFICATIONS Cost iron threaded fittings are UL& ULC Listed and FM Approved. Cast iron per ASTM A126. Dimensions conform to ANSI 816.4 Class 125. Threads ore NPT per ANSI/ASME B1.20.1, crrn OPPROVIO ,, � . NM at at or 90 ELBOW Nang SheMax.Working Dimensions Ann*. ,,,_ Pressures. A B Wt.Each F izs N1 G►ugi now AL dnml AR Gmr1 1t ,, ,'~=; I 300 1.50 1.50 0�.$4 : 1! 300 1.75 1.75 1,34 47. =` � lh 300 1.94 1.94 1. 1 dD 2N5 49,i 021 0'a i ''a"5`. 2 300 2.25 2,25 2.90 ' 50 2N,5 Si 5 75 I 52 2h 300 2.70 2.70 4,75 65, 2045 68.3r. 60 55 2 d5 A-Voaidng Prsswrs Rohngs one for reio►oncs only land bowl Co Sch.40 pqu.For oho lc**UL/UIC,and r,M pne nvre ft.&VS VOCAUS.pOoldwilia,ploon visit ovrriliri,00rr,or oordod your let o1 Anvil Risorosentafivo DULL HEAD TEE (....2)Atww ;wvvr= Cast Iron - Class 125 Fittings MATERIAL SPECIFICATIONS Cost iron threaded fittings ore UL& ULC Listed f. _.•,, and FM Approved. of Cost iron per ASTM A126. Dimensions conform to ANSI 816,4'Class 125, 4 - Threads ore NPT per ANSI/ASME B 1.20.1, m UM APPROVED Farms � Orn . OMO. A ,o rOnnO ands BULL HEAD TEE Nominal 5iu Mex.Working Dimemion$ Approx. Presstaea A 8 ( WI,Eotli te,OW MON le km) It I*_ to 6mm1 .t 1 x 1 x 1Y, 300 1,67 1.67 ' 1.58 1.52 ' B j4 A-61 Ea,(5z3 2016 4E4J 41.41r 40 13;% ttoi ,o 1x1xi'h 300 L8 1.8 1.65 1.73 4 r , ..^. a r.r .. 1YYxIx14 300 1.88 1.8 1.82 2.05 „r'. I1bx1vx1Y 300 1.88 1.88 1.82 2.21 U 't't '?d 4) IL c� , ,7 I 4 �,,5`t 46 38 1 6) $3 ,..liftliii iv,,x11x2 300 2.1 2.1 1.9 2.55 T 1�hx1%x2 300 2.16 2.1 2.02 2.80 4:3ujir4 tJF5 5,4644 SJ.I4 5J.3354 :.. 114x1Yrx2 300 2.16 2.16 2.02 3.28 2x2x2' _ 300 2.6 2.6 2.39 5.10 92 4 i A t••i.) I,) 5 o t.314 4 t i`s t3 7 Ul" 2 j-^waking Pressure Ratings are for reference only and baled onf 5th.40 pipe.Forke k4eo �tC,r k pressure ratings teems pips sdfwe.U� Please vise prM1iJintcan ar Conia!rut i coi Anvil itsprewoolive REDUCING 90° ELBOW (1r) -A4,41193.11; (t: 1C -PF/RNVIL-D),) Cast Iron - Class 125 Fittings MATERIAL SPECIFICATIONS Cast iron threaded fittings are UL& ULC listed and FM Approved. Cast iron per ASTM A126. N..... Dimensions conform to ANSI B16.4 Class 125. Threads are NPT per ANSI/ASME B1,20,1, ces <> WIWI OPPROVE0 Ft*ObtrOlINAMNAlli WS*Aktoii LAMialtors t air websan at worwaArAnti oxn or {,0410 Oh,1104d.Sias R.0.041.4114* REDUCING 90 ELBOW Max.Working Ohniursions Apron. NonintA Site Pressure* A 8 WI.Esti is ORO B PS/Orit) le.Anod is lord ik.Ogt) i"4- ---41 ixii 3/4 1.26 1.36 0.64 'ge701,10-4-4 31 00 3;34 0 29 ,,,,x7f4r4,5t4tt, 01 1 x 3/4 300 1.37 1.45 0.87 1Vis',6 300 134 1.53 0.96 A ta 32,05 71,4 34 03 3E e: 0 4 4 ../._ rata ritt14 W PAX% a® 1.45 1.62 1.13 i 32 3 20 2025 2e-63 4314 031 1.4,41 300 1.58 1.61 1.16 3 x 23 2L',63 _ 40 13 ., 42 4, 112,04 300 1.41 1.66 Ili 0 03 106 33 61 42 36 013 bi x 14 300 1.52 1.75 1.28 40 i 20 206.!` 3;3 64 44 45 0 333 300 1.65 1.80 1.51 46 A 24 2015 4?ci 45 7,? 013 Phx114 300 132 1,:; 1.62 40 s 3; 704.5 46 n 41 13 013 2 x 1/2 300 1.49 1.88 2.00 3 l'..!,42 2 a..,.; 32 64 41 7:' 0 Fi 2 x 3/4. 300 1.60 1.97 2.05 204.5. 4:0 4 60 03 0 P3 2x 1 300 1.73 2,02 2,10 50 A 23 2010 1:'14 5)3. 0"i.:- 2x1V4 300 1.90 2.10 2.30 41';': :S.3,:i.'.: '04 2 x11/1 300 2.02 2.16 2.60 50,4' ir';:. A^Working Pressure lkokcp are for reference only ond booed on Sch 40 pipe For the lases IA/ULC,and FM pressure rulings versus pipe allyz144,pleose t onvilir41.com or conicori yowl'local AnvO Itepresereolive REDUCING COUPLING N , r.,t! Cast Iron - Class 125 Fittings MATERIAL SPECIFICATIONS Cast iron threaded Fittings are UL& ULC Listed and FM Approved. Cast iron per ASTM A126. Dimensions conform to ANSI B 16.4 Class 125. Threads ore NPT per ANSI/ASME 81.20.1. URIII APPROVED rw lhMgstAppirm Waft and lrnmUwa.. Waif our«ruin at rawrnaaaemn w contri an Mw4fl WIN REDUCING COUPLING Nook Size Mix.Working Iron Approx, PressireA A WI.Each a I fnrrr) PSI NW It WO it tc,i+hP1 -# A 1 x Y 300 1.70 0.62 itr tyz I; 2114 d?ILL fit '. 1 x 1•, 300 1.70 0.Nd A-W4riarro Pressure Ramps are for reference only and hosed on sch.40 pipe.For dte bless UVUIC,and FM pressure ran nip west's pipe schedule,please tit omilinr cans or wood your bcoi Ara R,epresengfive, REDUCING TEE ()AfilY3111114 siwavr Cast Iron - Class 125 Fittings MATERIAL SPECIFICATIONS Cost iron threaded fittings are Ul& ULC listed I+-B-1-i-A and FM Approved. Cast iron per ASTM A126. . , Dimensions conform to ANSI B16.4 Class 125, i �� � Threads are NPT per ANSI/ASME B1,20.1. 41. C zitiligfft.:1_,f_ I $ Fw tAANAollopmfost 0A03 end LoAlbo eWM air robs*at grominv1601can or maim an REDUCING TEE Box, Dimensions REDUCING TEE APProx- Nominal Size Working 8 Wt.Ea& Mex. Dimensions Approx. . Nominal Size' Working Wi,Led, k[.eel ?SION lx.OW lx fist) to ' At 610 Pressure. A 8 C 1 x V x 1 300 159 1,36 1.50 1.i; lx feral NON k OW k(nasal it(i& &1}I) 75x75x1` 2R5 8 34.44 3F'i' 0'44 1-1ix1Y�x115 300 1.94 1.88 1.94 2.45 1 x4x 1 300 1.50 1.45 1.50 1.18 40r31x 15 2055 4922 471 4924 1. .5A20,v25 'Vr5 38;50 3432 353' r 4 11/4.x1Yx'1 300 1,41 1,41 1,66 1.76 1 x 1 x Y 300 1.26 1.26 1,36 0.95 40,x 4 x 40 2365 23.81 35.3 43 5 V"50 13725xi5 ?(36) 33.0 u4;r�; 349,4 1143 1'rx1tix1+ 300 1,52 1.52 1.75 1.87 1 x 1 x l 300 1,37 1.37 1A5 1,10 40x 40,23 2051 255,1 ,9.50 44 45 C.85 253 25 x 20 ;4, 5 34/5 34.79 36 3 9.50 114 1! x 1 300 1.65 1,65 1.80 1,94 1 xtxl 300 1.34 1.26 1.53 1;17 40 C.;x2` 7{:, 47 ) 41:5 4572 5. 1%r x 1 x 1 300 1.45 1,37 1.62 1,38 4 1 x 115 x l I, 300 1,8? 1.82 1.88 2,29 :ii A25 A 70 2665 36 E:3 i.7 47.74 0;53 11,4x1.1 300 1.58 1.50 1.57 1,47 2 x 1 x 2 300 4!5 313 225 3.54 wr7riias''4 7vr.4 45'?y r'is; + r`-� �-5i 4�'�et)xt� ��`� !.'i5 $3.s't� 4'�i �5" 2x15542 300 2.25 2.10 2.25 2.80 1%x 1 x 1% 300 1.75 1,67 1.75 1.80 44+x,3013.0 .�3r5 57;5 5:534 57 3.2i 32).25132 '. .0S; 667 44 45 42.# 4 ! ,�,_, 2 x 1'AS x%. 300 1.49 1.41 1.88 2.09 1Y+x1%x% 300 1.34 1.34 1.53 1.31 34x4,A3a rocs3 rs4 35.8; 4r1; 39; 32A32A35 2t116$ 3403 3483 388: 05 1fx15+x� 300 1,45 1,45 1,62 1,54 2x115x1. 300 1.b0 1,52 1.97 2.40 fi .,. ..�, n.- SC�F�;"'t:l� tiis',e. 4t'.'�' .i'3'..�;,� yiii)7 I.U2 37 A 3,.i 26 ru55 35 5i 36.,52 4)1.4 10.7Or .... 1 V x 1 k5 x 1 300 1.58 1,58 1,67 1.65 2 x 1°f1 x 1 300 1.73 4,65 202 2.55 i, 5 n6 40Lt 40.13 424: 075 S{!? x14 :`35 4a 4 4i.4 5) ''; }< A37X7 l h x l x'�5 3 r.;. 2 x 1%x 1 v; 300 190 1.82 7.10 2.85 1,41 1.34 1,66 1,41 50 4 d,A 3.:' 241 `= 43.7. 46 72 53:34 i.31.) 43i25xl< 21'43 .3;.573 34.7,3 42''5 0.54 2x15x115 300 1,49 1A1 1.88 2.24 1551 1 xVs 300 1.52 1.37 175 1.65 4, 4 x4CY40 20:75 32.1°74 9,'a,ur 47:1.7 t,f: 40x25a20 2ta7, .C4 34.13 4444 0"7* 2x1f x2 300 2.25 2,16 2,25 3.75 1' x 1 x 1 3001.65 1,50 i.;+s 1.65 5V it,, 3r,., t,=.i' 54.uer. 41 i5 ,,7i' 40125 z 25 7(36 41.9) i,1 1;12 115 2 x 2 x 5 300 1.49 149 1.88 2.60 1°!tx1x115 300 1.82 1.b7 1.r; 200 5oa5 x75 21;b 1.4 1. 4 4775 i;t ?x 2 x 1'1 300 1.60 1.60 1.97 231 1 e!s x 1 x 115 300 1.94 1.8 194 2,30 . 5�9 r 5,',x.'iJ `3a5 �15'64 4�;.f4 ii t3 i 1 23 40 25r4 .7?G5 49.21 4.5,2 452 ..'r 4 2x2x1 300 1,73 1.73 2,02 2,97 115x1, x 5 300 1.41 1.34 1,66 1.58 33, 5ta;5, "065 43'74 43:24 '2.. 1.f 40132.e 5 A163 , 35.3, :4.62 ;,16 an 2 x 2 x t , 300 1.90 1,90 2.10 3.32 lYrxl'rlxti 300 1.52 1.45 1,75 1,72 55� 5,x 32 ;*...5 ,3;',"eL 4k6 32 34 ;4, �5' `4.33 212x134 300 2.02 2.02 7.16 3.72 115x155xl 300 1.65 1.58 1. 1.85 40x 3ekE5 i4i4 4r.? .5! 4.>..}2 54' .-WOlui_.. insXC notion Me 6 lo.4nww,,Ml'ond beexi M. .•�p�e.FP iiie 1,5 x 1 If x 1 300 1.82 175 1.88 2.22 t$uJt,and FM protium r ,,,gs verses pipe teheei,aa,phase riri avi l tem or 435!37A;2 r5t:5 46.2f '4, 47,25 i 00 mew your local Anvil ReproSlreative . . STRAIGHT TEE (),6141113f4116: 4C<CC-1512F/ ' Cast Iron - Class 125 Fittings •, , MATERIAL SPECIFICATIONS .....,- Cast iron threaded fittings are UL& ULC Listed and FM Approved. I Cast iron per ASTM A126. i 1 Dimensions conform to ANSI 816.4 Class 125. Threads are NPT per ANSI/ASME 81-20,1„ MID APPROVIO kr Ust A-ost oWrowig Ittrda016 Anti tottiolocos. troli ow%Amin atirmanoillne corn or c an MVP WHY RtP(*Wattat STRAIGHT TEE National site Max.Working P Dimensions AProx,ressure. it g Wt.Inch I.—A—.1.—A--1 , . it uwo MAP& le.firent it ket tbs,* , -77. ...„,.._ pa " 300 1.75 1.15 1.87 B 1 ci 300 194 1,94 2,51 1 69-6&811111,68.ft ,4 t 2 300 2,25 2,25 3.96 26 300 2.70 2.70 6.45 i Elz'i 1.8 5 6E!,. 2 93 A-Waiting Prawn*&Onion are for ratinanco only and 60.4 on Soh 40 pp*Fork laktil MAC,and FM proseNno rafingt yousut pipe schodale,Opole visit anyilinti aim or cordad rut bed MAI Repmentativr. SA} l F +L'x .. k M l V' '1 ,�. ‘,AN A k. ....„,,.i_),,..-,„,„,.,,.,-,.....-.,.„,,,.„.?'..,,,,,.A1.y,,.A,..—,A,.....,,.:,,,.:...,:1,.,,',.,„„.„.A;..',A„::,..>,-fi3,4A,:',.„A A,,.ii.,„:!„n,,,,..%,:"F„.r......,„„,3 i..6.,,',g,A.7i,x..,.,„,,,,,,„,AAi;,,-,,1..'..„A, •.,.,i-.:.',o‘4-t.-1 4),,„,c,. .-,_:AA.,,..-:..,,.:,„ r, ,. '.-,',"::, 9 _ --, --"-i'„.„..._7—,, '_. e..,. Jj ' #..��. •r_ �� /ter . . - n , ..,. „; ., . ......„,„. 144t:!a . kn'k i., .. ___„. .......„ .;tom „.J_ §M1s '43 F 'y yG T.I. HANGERS AND SUPPORTS Page 1 of 3 Fasten al Product Standard REV-06 Date:January 11,2019 TROD.316 Threaded Rod,316 Stainless Steel This product standard contains the required dimensional,mechanical,performance, and chemical characteristics of the products shown in this purchase order(as applicable to the product). Unless specified below,current revisions of national or international standards shall be applicable as of the date of Fastenal's purchase order and must be adhered to in their entirety. If the order received does not meet these requirements,corrective action may be issued which could jeopardize your status as an approved supplier to Fastenal. 0101 1.,,, ,,T ,r , r D Diameter Nominal D (Major Diameter) Size Max. Min. #2-56* .0860 .0854 .0813 #4-40* .1120 .1112 .1061 #6-32* .1380 .1372 .1312 #8-32* .1640 .1631 .1571 #10-24* .1900 .1890 .1818 #10-32* .1900 .1891 .1831 1/4-20 .2500 .2489 .2367 1/4-28 .2500 .2490 .2392 5/16-18 .3125 .3113 .2982 5/16-24 .3125 .3114 .3006 3/8-16 .3750 .3737 .3595 3/8-24 .3750 .3739 .3631 7/16-14 .4375 .4361 .4206 7/16-20 .4375 .4362 .4240 *Class 2A threads shall be used for sizes where 1A is not applicable RECORD OF REVISION CHANGES TO THIS DOCUM ENT ARE LOCATED ON THE LAST PAGE R a Page 2 of 3 Fastenal Product Standard REV-06 Date:January 11,2019 FASIENAC TROD.316 Diameter Nominal D (Major Diameter) Size Max. Min. 1/2-13 .5000 .4985 .4822 1/2-20 .5000 .4987 .4865 9/16-12 .5625 .5609 .5437 5/8-11 .6250 .6233 .6051 5/8-18 .6250 .6236 .6105 3/4-10 .7500 .7482 .7288 3/4-16 .7500 .7485 .7343 7/8-9 .8750 .8731 .8523 7/8-14 .8750 .8734 .8631 1-8 1.000 .9980 .9755 1-14* 1.000 .9984 .9881 1 1/8-7 1.125 1.1228 1.0982 1 1/8-8* 1.125 1.1229 1.1079 1 1/8-12 1.125 1.1232 1.1060 1 1/4-7 1.250 1.2478 1.2232 1 1/4-12 1.250 1.2482 1.2368 1 3/8-6 1.375 1.3726 1.3544 1 1/4-12 1.250 1.2482 1.2310 1 3/8-6 1.375 1.3726 1.3453 1 1/2-6 1.500 1.4976 1.4703 1 5/8-8* 1.625 1.6228 1.6078 2-4.5 2.000 1.9971 1.9751 *Class 2A threads shall be used for sizes where 1A is not applicable Length Tolerance 3' +/- 1/4" 6'- 12' +/- 1/2" Length shall be measured fromend to end Specification Requirements: • Dimensions: ASMEB18.31.3 • Material: UNS S31600 Stainless Steel • Mechanical Properties: CW,Group 2 perASTM F593 shall be accepted for all diameters listed in the table above,per their respective tensile stress areas • Thread Requirements: Rolled threads to ASMEB1.1,UNC,UNF,UNS &UN8 Class lA • Product Marking: Marked with predetermined color on rod end. Vendor to supply colorcodewith the MTRand purchase order. • Finish: Per ASTM A380/A380M • Material Test Reports: The MTRmust have documented lot traceability,dimensional results,full chemical test results and full mechanical test results to the specification(s)above. In addition,the MTRshallbe in full compliance with Fastenal's MTRRequirements. � M Page 3 of 3 Fastenal Product Standard REV-06 Date:January 11,2019 FAMINE TROD.316 Revision Level Changes to this Document Document Name Revision Revision Rationale for Revision Level Date TROD.316 06 1/11/2019 Revised finish specification. The rationale above may not include all of the changes within each revision. A complete review of the Fastenal Product Standard is required. :yx a v: 41r � Jj � 3 V. : Y r StN a y -'s, Y'r t 1 FSAMM YS '�1�� _ - �- �: Ufa' T "' z ' ,hr� L , , p �-� `r..-.��; _`r � i�`'-..r ''.,;.- � _' du .?;� ,._";.;,,fir, •4'�' 4 �,'r„_: ,- �.' r..t,; ..:'a�.,... " SAMMYS° FOR WOOD - Vertical Application Application Product Features Not less than Wood Flooring •No pre-drilling required. 2"nominal width (1 / •Quick to install using the Sammy Not less than Nut Driver with an 18V cordless Ie 3"nominal drill/driver. thickness(2-1/2") (depth or side Wood Joist •Saves time from traditional of vertical member) E:; - - = -:` :1 methods. Double Sheetrock IFor vertical use- Ceiling •Reduces installation costs. install in center of lower face. Minimum 2"embedment into base •Manufactured in the U.S.A. material for NFPA 13 compliance. Composite/Truss • Consult truss manufacturer for a recommended installation point. Pre-drilling may be required for GST 25-380.Tool available on page If. i„ ,. Ill Watch a video demonstration at www.itwbuildex.com Approvals Rod Part Model Screw Ultimate ULTest FM Test Box Case Size Number Descriptions Pullout(Ibs) Load(Ibs) Load(Ibs) Qty Qty VERTICAL MOUNT 1/4" 8002957 GST 100 1/4 x 1" 210 (7/16"OSB) 25 125 670 (3/4"Ply) "" .'tr4" 1,0039`?7 GST 200 t14 x 2" . ,..( r) ... 2 , . (25 Q- h 3/8" 8007957 GST 10 1(4 x l" 210 (7/16"OSB) 300 25 125 670 (3/4"Ply) '` ;..318". .. ..,80t3895 _SST 20 "' .114 x 2' i7 0{Far) r .� _ 1475,=- 25 'f ,; ri — r :;'-. 3/8" 8068925 GST 20-SS 114 x 2" 1760 (Fir) 850 25 125 #14 Black .;3/8". .. 800 2,5 aGST25-380 31b x2 i2" 2Y13'Fir) ,�. , 25 125 Nut Driver 3/8" 8010957 GST 30 1/4 x 3" 2060 (Fir) 1500 1475 25 125 Part#8113910 „` _ 2f8 ,,..8069926 G51'3tl;ou5...,.,V4 x 2 : 2 .'49/a 25 ;rxr.,, ,>: 1/2" 8013925 GST 2 1/4 x 2" 1760 (Fir) 25 125 x 112a 8015925 'CAST 3 ., ' 114'x'3",., .:�-2275(Fir) ... s 25 .., 1255 , #14 SW Red Nut Driver Part#8114910 A vf oxs Mvnurocnuveo U.S.A SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes into contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. For the most up to date information,visit www.itwbuildex.com 4 MiiiiiiiiiMilliiiiMINI Zt A NNYZ® SIDEWINDER® FOR WOOD -Horizontal Application Application Product Features i. Not less than 2"nominal width •No pre-drilling required. (1-1/2")up to 3-112"pipe;not less than 3"(2-1/2")nominal width 4"&5"pipe ), •Quick to install using the Sammy 1—/ Floor Joist Nut Driver with an 18V cordless drill/driver. Minimum 2-1/2"from bottom for branch lines.Minimum 3"from bot- tom for main lines.Exception:This •Saves time from traditional requirement shall not apply to 2"or methods. thicker nailing strips resting on top of steel beams. F � •Reduces installation costs. •Manufactured in the U.S.A. Composite I Truss Consult trussmanufaclurerfor recommended installation point. ? "Pre-drilling may be required for Model SWG 25-380.Tool available on page 11. Watch a video demonstration at www.rtwbuildex.com) Approvals Rod Part Model Screw Ultimate UL Test Box Case Size Number Descriptions Pullout(Ibs) Load(Ibs) Qty Qty HORIZONTAL MOUNT 1/4" 8019957 SWG 200 114 x 2" 1725 (Fir) 25 125 2 95 3i8 � 892t}}957 Li 10 r. -1 x4 . r (Fu)``. . 300 ;:25 i 12$ Q. 3/8" 8021957 SWG 20 1/4 x 2" 1725 (Fir) 1050 25 125 a . .- 3/8" - ,.:. 8073925 ;;.. .. ,TWO 20•SS ° 1/4 x2" ;', 1.fr25,F 'r 850 25 ¶25 Q.. 3/8"* 8022925 SWG 25-380 3/8 x 2-1/2" 2249 (Fir) 1500 25 125 3/8" 8023925- r 4 #14 SW Red _ v SWG, 1/4 x 3" f884r fiT) 125 Nut Driver Part#8114910 *May require pre-drilling;consult joist manufacturer. F SAMMYS SWIVEL HEADTM FOR WOOD - Swivel Application • Application Product Features 4 •Eliminates distortion of threaded rod. •Accommodates up to 3%"x 12 pitch roof. *Allows 17°deflection from vertical. , woo •Saves time from traditional methods. 4, 1 « •Reduces installation costs. .• w�N1Daeor MAX Ir I Etl ! Manufactured in the U.S.A. el Rod Part Screw Ultimate UL Test Load FM Test Min Box Case Approvals Size Number Model Descriptions Pullout(Ibs) (Ibs) Load(Ibs) Thickness Qty Qty #14 Black — SWIVEL MOUNT ,. d Nut Driver — Q X ••' 3/8" 8139957 SH-GST 20 1/4 x 2" 1257(Fir) 1050 1475 25 125 Part#8113910 1903 Dim.Lumber , 4000;;''k--: ' -,--';' ; -- :i i ° - :" ,3/8 825 51 $1W GST/G&T20;'i/15 x 13/4° ;1406 @ 45°of ver4cai $5D 45° 25 125 : v.. Dire.Lumber 903 Dim.Lumber 1/2" 8303957 SH-GST/CST 2.0 5/16 x 1-3/4" 1406 @ 45°off vertical 25 125 Dim.Lumber *May require pre-drilling;consult joist manufacturer. #14 SI I Orange qi Nut Driver Part#8273910 •' • 5 To find a distributor near you,call 800-BUILDEX Pipe Hangers Fig. 200 - "Trimline" Adjustable Band Hanger (B-Line Fig. B317ONF) goro'CC7 Fig. 200F- "Trimline" Adjustable Band Hanger with Felt Lining (B-Line Fig. B317ONFF) C.(:)I.18 Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line Fig.B317ONFC) LISTED Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig. 200 - 1/2" (15mm)thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled -- swivel nut design permits hanger adjustment after installation. Features: b ® ,_- • (1/2" (15mm)thru 2" (50mm)) Flared edges ease installation for all pipe `"'� types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily n i s B installed around pipe. For hanger with non-captured nut order Fig. 200S. ' A �j • (21/2" (65mm)thru 8" (20omm)) Spring tension on nut holds it securely in hanger before installation.Adjusting nut is easily removed. i Approvals: Underwriters Laboratories listed (1/2" (15mm)thru 8" (20omm)) Fig.200-1/2.200-3/4 in the USA(UL)and Canada (cUL)for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (FM) (3/4" (20mm)thru 8" (200mm)). Fig.200-'1 to 200-2 Fig.200-21/zto200-8 Conforms to Federal Specifications WW-H-171 E &A-A-1192A,Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69&SP-58, Type 10. Maximum Temperature: 650°F (343°C) , " t Finish: Pre-Galvanized. Stainless Steel . materials will be supplied with (2) hex nuts11 in place of a knurl nut. Order By: Figure number and pipe size '.t.. Designed to meet or exceed requirements of FM DS 2-0. t_> Fig.200 Fig.200C Fig.200F Pipe Size Rod Size A B Approx.Wt./100 Part No. in. (mm) in. (mm► in. (mm) lbs. (kg) ;r t 200-1/2 1/2" (15) 3/8"-16 31/8" (79.4) 25/8" (66.7) 11 (5.0) , 200-3/4 3/4" (20) 3/8"-16 31/8" (79.4) 21/2" (63.5) 11 (5.0) , f 200-1 1" (25) 3/8"-16 33/8" (85.7) 25/8" (66.7) 12 (5.5) `r 200-11/4 11/4 (32) 3/8'-16 33/4" (94.0) 27/8' (73.0) 13 (5.9) rX R 200-11/2 11/2" (40) 3/8"-16 37/8" (98.4) 27/8" (73.0) 14 (6.4) 200-2 2" (50) 3/8"-16 41/2" (114.3) 3" (76.3) 15 (6.9) 200-21/2 21/2" (65) 3/8"-16 55/8" (142.9) 41/8" (104.7) 27 (12.3) ,,• 200-3 3" (75) 3/t"-16 57/s" (149.1) 4" (101.6) 29 (13.3) Fig.200S 200-31/2 31/2" (90) 3/8"-16 73/8" (187.3) 51/4" (133.3) 34 (15.6) 200-4 4" (100) 3/8"-16 73/8" (187.31 5" (127.0) 35 (16.0) 200-5 5" (125) 1/2"-13 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200-6 6" (150) 1/2"-13 101/8" (257.2) 63/4" (171.4) 73 (33.4) 200-8 8" (200) 1/2"-13 131/8" (333.4) 83/4" (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line Protection Solutions 21 by 'S Pipe Hangers TOLCOTM Fig. 200H - Heavy Duty Band Hanger(For Trapeze) Size Range: 2" (50mm)thru 4" (100mm)trapeze pipe size. Material: Steel—Pre-Galvanized to G40 Spec Function: Designed primarily to support substantially heavier loads �Jr;� than is normally intended for the nominal hanger size. Used .. ,,,' extensively to support trapeze installations and the increased loads LISTED from both above and below the trapeze assembly. Features: Furnished with 3/8"-16 or 1/2"-13 adjusting threaded ring nut. Approvals: Underwriters Laboratories listed in the USA(UL)and B Canada** (cUL). Conforms to Federal Specification WW-H-171 E & A-A-1192A,Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69&SP-58, Type 10. A Maximum Temperature: 650°F(343°C) Finish: Pre-Galvanized Order By: Part number, pipe size and rod size. Important Design Note. Because of the increased loads applied to the trapeze assembly, both the upper trapeze supports as well as the lower hanging unit must be able to hold the maximum loads intended. T I 1 1 Q r 1 1 1 L I Pipe Size Rod Size A B Max.Rec.Load Approx.Wt./100 Part No. in. (mm) in. (mm) in. (mm) lbs. (kN) lbs. (kg) 200H-2-3/8 2" (50) 3/8"-16 49/16" (115.91 37/32" (81.7) 1200 (5:34) 48 (21.8) 200H-2-1/2 2" (50) 1/2"-13 423/32" (119.81 33/8" (85.7) 1200 (5.34) 45 (20.4) 200H-21/2-3/11 21/2" (65) 3/8"-16 55/16" (134.9) °? 323/32" (94.4) 1200 (5.34) 59 (26.7) 200H-21/2-1/2 21/2" (65) 1/2"-13 515/32" (138.9) 37/8" (98.3) 1200 (5.34) 56 (25.4) 200H-3-3/a 3" ` (75) 3/8"-16 53/4" (146.0) 327/32" (97.6) 1200 (5.34) 63 (28.6) 200H-3-1/2 3" (75) 1/2"-13 57/8" (148.1) 331/32" (100.8) 1200 (5.34) 60 (27.2) 200H-4-3/8 4" (100) 3/8"-16 67/8 (174.6) 47/i6" (112.7) 1200 (5.34) 76 (34.5) 200H-4-1/2 4" (100) 1/2"-13 71/32" (178.6) 419/32"(1116.7) 1200 (5.34) 73 (33.1) Note: Select trapeze pipe size based on section modulus required for span of trapeze per information provided in NFPA 13 (2002)Table 9.1.1.6.1 (a and b). All sizes are UL Listed to support up to 8"pipe at max spacing per NFPA 13. For 6" (150mm)and 8" (200mm)trapeze pipe,consult factory. All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. Eaton 61 B-Line series Pipe Hangers&Supports P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 552 TAPPED BRACKET SIZE-ROD: 3/8" SIZE-SYSTEM PIPE:4"max. A MATERIAL-Carbon Steel. 0 FINISH Plain or E.G. 2.3125 LISTING/APPROVAL- *— DLISIEDDS203-EX 2551 1 1/2 1 �1.250 FUNCTION-Attachment component of an AFCON hanger. 4!" To support horizontal piping. INSTALLATION-Per NFPA 13 and these instructions. Install on vertical mounting surface. ASSEMBLY/ATTACHMENT- Center mounting hole accepts 3/8"and 1/2" fasteners. �� FASTENERS PER NFPA 13 Dix eD* MOUNTING FASTENERS DS LISTED FOR STEEL PIPE -SEE TABLE. Wood Steel - 1/4"or#14 Tek Fastener Qtv. Steel Min. Steel FEATURES No Pre-drill pipe Thickness Qty. Pipe *Vertical fastener mounting: #14x1 1/2 SMS 1 2 14 GA. 1 3 Hangs plumb from first fastener. #14x2 SMS 2 4 2 4 Stops wood splitting along the grain. 1/4 x 2 LB 1 2 1/2 16 GA. 1 2 *No speed/pal nuts re required. 2 4 2 3 9 #16x2 DS 2 2 18 GA. 2 21/4 ORDERING-Part#and finish. SMS=Sheet Metal Screw LB=Lag Boll DS=Drive Screw WS=Wood Spew 553 BRACKET SIZE-ROD:3/8" 0 SIZE-SYSTEM PIPE:4"max. 0 MATERIAL-Carbon Steel. 0 FINISH-Plain or E.G. LISTING/APPROVAL- B/ `t,h)DDs203-EX 2551 NOTE- Criteria same as 552 above except 13/32"rod hole. Install hanger rod with 3/8"nut. 4/11 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 555 BRACKET SIZE-ROD: 1/2" SIZE-SYSTEM PIPE: 8"max. �hti5� MATERIAL-Carbon Steel. FINISH-Plain or E.G. LISTING/APPROVAL- / 1°1 ` ��i�sreo°'203— EX 2551 ff o A 5 ti FUNCTION Attachment component of an AFCON hanger. INSTALLATION- Per NFPA 13 and these instructions. is°� Install on vertical mounting surface. ASSEMBLY/ATTACHMENT- Mounting hole accepts 1/2"or 5/8"fasteners. FEATURES-Tapped rod bore. ORDERING-Part#and finish. 556 BRACKET SIZE-ROD: 1/2" / SIZE-SYSTEM PIPE:8"max. MATERIAL-Carbon Steel. Le, FINISH-Plain or E.G. LISTING/APPROVAL- euOU oa203- EX 2551 NOTE-Criteria same as 555 except smooth 17/32"rod bore. Install hanger rod with'/2"nut. 4/13 Mounting Hardware & Supports Eaton's B-Line series is a leading manufacturer of high quality support systems for the data communications and from all threaded rod to U,V and J bolts and more, Eaton offers a complete line of hardware to help complete a professional installation. Material: Type Specification Steel ASTM A307 and SAE J429 Silicon Bronze (BR) ASTM F468 Finishes: -Zinc Plated (ZN) ASTM B633 -Yellow Zinc (YZ) ASTM B633 - Black Zinc (BZ) ASTM B633 ZN (YZ) (BZ) l ) Zinc Plated Yellow Zinc Black Zinc B-Line series Server&Network Solutions www.eaton.com 357 Mounting Hardware & Supports All Threaded Drop Rod Part Rod Weight • Rolled threads for added strength Number Length Per Rod • In. (mm) Lbs. (kg) Loading Capacity(Safety Factor of 5) 3/e"-16 = 610 lbs. (2.71 kN) %"-16 Thread Size W-13 = 1130 lbs. (5.02 kN) ATR%x12YZN 12" (305) 0.3 (0.13) 5/a" 11 = 1810 lbs. (8.05 kN) ATR%x36YZN 36" (914) 0.9 (0.41) • Sold per 100 ft. (30.5m) • Material:ASTM A307 Gr. A steel ATR%x72YZN 72" (1829) 1.9 (0.86) ATRS/sx120YZN t 120" (3048) 1 3.1 (1.40) • Finish:Yellow zinc(YZN) (Other finishes available upon request) ATR%x144YZN 1144" (3657) 3.8 (1.72) 1/2"-13 Thread Size ATR'/2x12YZN 12" (305) 0.6 (0.27) ATRY2x36YZN 36" (914) 1.8 (0.81) ATR'/2x72YZN 72" (1829) 3.6 (1.63) ATRV2x120YZN 120" (3048) 6.0 (2.72) '�R ATR'/2x144YZN : 144" (3657) 7.2 (3.26) %"-11 Thread Size _-R,1` ,,'_. ATRS/sx12YZN 12" (305) 1.0 (0.45) �� -, ATRfsx36YZN ; 36" (914) 3.0 (1.36) �\V��� ��' ATRS/sx72YZN 72" (1829) 6.0 (2.72) 1-'1,1,:e.,`) ATRS/sx120YZN 120" (3048) 10.0 (4.53) ) ATR%x144YZN 144" (3657) 12.0 (5.44) �t Threaded Rod Coupling • Material: ASTM A307 Gr.A steel • Finish: Clear zinc(ZN) Part Thread Coupling Weight "t.._ Number Size Length ,#' "t ,, N' In. (mm) Lbs. (kg) (( ' " B655-% 3/8"-16 11/8" (28) 0.02 (0.01) .: B655 B656-'/sx'/s 3/8"-16&'/8"-13 11/8" (32) 0.07 ' (0.03) B655-'/s '/8"-13 1%" (44) 0.11 (0.05) B655 5/e S/8"-11 21/4" (54) 0.18 ` (0.08) ,- `' B656%x'Is 1/8"-13 &5/8"-11 11/8" (32) 0.14 (0.06) �� . • B656 358 8-Line series Server&Network Solutions www.eaton.com Mounting Hardware & Supports Threaded Rod Protector • Use to protect cabling from the all threaded rod • UL-94 VO material for flame resistance • Material: PVC • Finish Color: Gray • Part Thread 'L' Weight Number Size In. (mm) Lbs. (kg) SB3011/2x8 1h"-13 8" (203) 0.03 (0.01) SB3015/sx8 5/8"-11 8" (203) 0.04 (0.02) SB3011/2x72 '/2"-13 72" (1829) 0.23 (0.10) SB301%x72 1 %'-11 72" (1829) 0.32 (0.14) Threaded Rod End Cap • Use to provide a protective covering for exposed threads on threaded rods, cap screws, etc • Sold in packages of 10 • Material: Polyethylene • Finish Color:Yellow Part Hardware Weight Number Size per Package Lbs. (kg) SB300B 3/8"-16 0.04 (0.018) SB300C 1/2"-13 0.05 (0.022) SB300D 5/8"-11 0.06 (0.027) B-Line series Server&Network Solutions www.eaton.com 359 Mounting Hardware & Supports "U" Bolt • Includes: hardware shown • Finish : Black zinc(BZ) or • Material: SAE J429 steel Yellow zinc(YZ) Other finishes are available upon request Part 'A' 'B' 'C' Thread Weight Number Size , Per 100 C0 In. (mm) In. (mm) In. (mm) Lbs. (kg) SB1001A_ 3" (76) 11/4" (32) 31/s" (79) 1/2"-13 18 (8.1) %IMl SB1001B_ 41/2 (114) 11/2" (38) 31/s" (79) '/z"-13 23 (10.4) 'B' . SB1001E_ 51/2" (140) 1'/2" (38) 119/32" (40) 3/8"-16 34 (15.4) to SB1001M_ 5" (127) 11/2" (38) 41/s" (105) i 1/2"-13 75 (34.0) te .11 SB1001S_ 5" (127) 1" (25) 51/4" (133) 1/2"-13 84 (38.1) C A SB1001U_ 4" (101) 1" (25) 1%6" (39) 1/2"-13 54 (24.5), Specify part number and finish when ordering. "V" Bolt • Designed for use with angle iron • Finish_: Black zinc(BZ)or • Includes: hardware shown Yellow zinc(YZ) • Material: SAE J429 steel Other finishes are available upon request Part 'A' 'B' 'C' 'D' , Thread ' Weight Number Size Per 100 ^� In. (mm) In. (mm) In. (mm) In. (mm) Lbs. (kg) w. SB100203A_ 3" (76) 21/26" (52) 11/8" (28) 11/4" (32) 3/4"-16 21 (9.5) tadc. SB100203B_ 4" (101) 21/16" (52) i 11/s" (28) 11/2" (32) 3/8"-16 26 (11.8) 'D' SB100203C_ 6' (152) 21/26" (52) 11/8" (28) 11/2" (32) 3/4"-16 36 (16.3) ,B, SB100204B_ 3" (76) 21/8 (54) 2" (51) '3/16" (20) , 1/2"-13 i 44 (19.9) ,,,,-00 SB100204D_ 4" (101) 21/8" (54) 2" (51) 1' " (32) 1/2"-13 52 (23.6) v SB100204G__. 5" (127) 21/8" (54) 2" (51) 2" (51) '"-13 ' 62 (28.1) A SB100204H_ 6" (152) 21/8" (54) 2" (51) 2" (51) 1/2"-13 71 (32.2) C Specify part number and finish when ordering. "J" Bolt • Includes: hardware shown • Finish_: Black zinc (BZ)or • Material: SAE J429 steel Yellow zinc(YZ) Other finishes are available upon request Part 'A' 'B' 'C' 'D' Thread Weight 'C Number Size Per 100 In. (mm) In. (mm) In. (mm) In. (mm) Lbs. (kg) 'A' SB1003A_ 2" (51) 1/4" (6) 1/2" (13) 1" (25) 5/16"-18 �� 13 (5.9) 'B'ti SB1003F_ 141/4" (108) 1/2" (13) 3/4" (19) 11/4" (32) 3/8"-16 31 (14.0) 0 'D' SB1003G i 31/" (89) 1%s" (20) 3/4" (19) 11/4" (32) 5/16""-18 20 (9.1) O 1ffh1 SB1003J_ 23/4" (28) 7A6" (11) 3/4" (19) 1'/4" (25) .l 5/16"-18 16 (7.2) I C SB1003K_ 5" (127) 1/2" (13) 3/4" (19) li 11/4" (32) li 5/6"-18 25 (11.3) i®1 SB1003M_ 33/4" (95) ' 7A6" (11) 3/4" (19) , 11/4" (32) 5/s"-18 20 (9.1) Specify part number and finish when ordering. 360 B-Line series Server&Network Solutions www.eaton.com Mounting Hardware & Supports Isolated Seismic Anchors Torque Nut (TN) or • For use in concrete in seismic applications Hex Nut (HN) • Complies with all NEBS GR-63-CORE requirements Flat Washer • Loading: 2700 Lbs (12.0kN)pull-out load with safety Belleville Washer factor of 3 2%" (60mm) Dia. • Material: Steel anchor&hardware with isolation washer Steel Washer Isolation Washer • Finish: Yellow zinc(YZN) 11/16" (27mm) Long Bushing 23/8" (60mm) Long Flare Sleeve 63/16" (157mm) Long M12 Shaft Part Overall Hole Weight M12 Wedge Nut Number Length Size Per 100 In. (mm) In. (mm) Lbs. (kg) ASSAM12157TN 63/16" (157) 11/s" (17) 100 (45.3) ASSAM12157HN 63/is" (157) 11/is" (17) 3 100 (45.3) Wedge Anchors • For use in concrete or stone • Material: steel with stainless steel clip liiit'J'1a1jY7E�,J;1;' Ar • Finish: Clear zinc(ZN) 1 Part Thread 'L' Hole Weight Number Size Length Size Per 100 In. (mm) In. (mm) Lbs. (kg) AWA-25-225 I 1/4"-20 21/4" (57) 1/4" (6) 3.7 (1.7) AWA-37-275-BLT 3/8'-16 234° (70) 3/8" (19) 18.8 (8.5) AWA-50-275 1/2"-13 23/4" (70) 1/2" (13) 18.8 (8.5) AWA-50=375 1/2"-13 33/4" (95) i 1/s" (13) 23.6 (10.7) AWA-62-350 5/8"-11 I 31/2" (89) %" (16) 36.0 (16.3) * Includes an additional%"fender washer. B-Line series Server&Network Solutions www.eaton.com 361 Mounting Hardware & Supports Drop-In Anchors • For use in concrete or stone • Use with machine screw, bolt, or threaded rod `�I • Material:Zamac#3 alloy Part Thread 'L' Thread Hole Weight Number Size Length Depth Size Per 100 In. (mm) In. (mm) In. (mm) Lbs. (kg) ADI-37 %"-16 19/16" (40) 5/6" (16) 1/2' (13) 3.2 (1.4) ADI-50 1/z"-13 2" (51) t3/16" (20) 5/9' (16) 5.8 (2.6) ADI-62 %"-11 21 (64) 13/6" (30) '/s" (22) 8.0 (3.6) ADI-75 3/4"-10 31/s' (79) 13/1s" (30) 1" (25) 12.5 (5.7) Single Expansion Anchors • For use in concrete, block, brick, or stone • Use with machine screw or bolt • Material:Zamac#3 alloy Part Thread 'L' Hole Weight Number Size Length Size Per 100 In. (mm) j In. (mm) Lbs. (kg) ASE-25 1/4"-20 15/16" (33) 1/2" (13) 3.6 (1.6) ASE-37 3/e"-16 11/2" (38) % (16) 6.4 (2.9) ASE-50 1/2"-13 2" (51) 7/8" (22) 12.4 (5.6) ASE-62 %"-11 25/a" (67) 1" (25) 20.5 (9.3) Toggle Bolts • For use in any type of hollow construction, drywall or block • Material: Steel • Finish: Clear zinc (ZN) m Part Thread 'L' Hole Weight Number Size Length Size Per 100 In. (mm) In. (mm) Lbs. (kg) ATB-25-300 1/4"-20 3" (76) 5/8" (16) i 5.8 (2.6) ATB-37-300 %'-16 3" (76) 7/s" (22) 14.4 (6.5) ATB-37-400 %"-16 4" (101) 7/s" (22) 17.6 (8.0) 362 B-Line series Server&Network Solutions www.eaton.com Mounting Hardware & Supports • Bolts and Screws • Threads: Class 2A, except • Finish:Yellow zinc(YZN) • For equipment rack / lag screw • Other sizes are available, mounting hardware see f -r • Material:ASTM A307 Gr. contact customer service page 44(SB58604) . A steel Part Thread 'L' Weight Number Size Length Per 100 In. (mm) Lbs. (kg) 5/,sX3/aSFHMSYZN : ::: : 3/a" (19)j 7/8" (22) 2.0 (0-91) 5/,eX1SFHMSYZN 5/,e"-18 1" (25) 3.0 (1.36) 'L' ►I %fsX1SFHMSYZN 3/8"-16 1" (25) 4.0 (1.81) Part Thread 1 'L' [ Weight Number Size Length Per 100 In. (mm) Lbs. (kg) 12-24X'/2SRHMSYZN #12-24 ' ' (13) 1.0 (0.45) 1�t \�4 1 �������� � �1 12-24X1SRHMSYZN #12-24 ; 1" (25) 2.0 (0.91) YX%SRHMSYZN 1/4"-20 3/a" (9) 1.0 (0.45) I. 'L' ►-1 1/4X%SRHMSYZN Y4"-20 , 3/4" (19) 2.0 (0.91) Part Thread 'L' I Weight Number Size Length Per 100 In. (mm) ! Lbs. (kg) 4 ( [ 12-24X'/2SPHMSYZN #12-24 '/z" (13) 1.0 (0.45) ��� �\\{{\\\\ �I�{�k(i��\l E�� 12-24X5/sSPHMSYZN #12-24 5/8' (16) j 2.1 (0.95) 'L' ,. 12-24X3/4SPHMSYZN #12-24 3/4" (19) 1.0 (0.45) Part Thread 'L' Weight Number Size Length Per 100 In. (mm) Lbs. (kg) 1/4X11/4SNCBYZN '/4"-20 11/4" (32) ! 2.0 (0.91) 5/,sX2Y4SNCBYZN 5/,6-18 2W (57) 5.0 (2.27) 111t`It `�i`�`��,����'�1�� b 5/16X23/4SNCBYZN 5/As"-18 23/4" (70) 6.0 (2.72) `!1 %X11/4SNCBYZN 3/s"-16 11/4" (32) 5.0 (2.27) LA 'L' 1.1 %X13/4SNCBYZN 3/s"-16 13/4" (44) 7.0 (3.17) s/sX2'/4SNCBYZN 3/s"-16 21/4" (57) 8.0 (3.63) Part Thread 'L' Weight Number Size Length Per 100 In. (mm) Lbs. (kg) 3/5X1'/zHHLSYZN 3/a" 11/2" (38) 4.0 (1.81) 41 %X2HHLSYZN 3/8" 2" (51) j 5.0 (2.27) %X2'hHHLSYZN 3/a" 21/2" (63) 8.0 (3.63) . 'L' 0. . Y2X2'/zHHLSYZN 'h" 2' (63) 15.0 (6.80) B-Line series Server&Network Solutions www.eaton.com 363 Mounting Hardware & Supports Steel Hex Head Cap Screw Bolt 'H' 'W' 'T' • No threads within two pitches of bolt head Size • Class 2A threads In. (mm) In. (mm) �'1 In. (mm) ' • Dimensions are for reference only '/4"-20 5/32" (3.97) 7/16" (11.1) 3/4" (19.0) • Material: SAE J429 grade 5 steel.ASTM F468 silicon 5/,6"-18 1/4" (6.35) 1/2". (12.7) ' '/s" (22.2) bronze %"-16 19/64" (7.54) 9/16" (14.3) 1" (25.4) • Finish:Yellow zinc(YZN) If 1 • Other sizes are available, contact customer service. '/z"-13 6/'s" (7.94) 3/4" (19.0) 1'/a" (31.7) 5/9"-11 t5/3i" (11.90) !� 15/16" (23.8) 11/2" (38.1) Part Weight Part Weight l' -11-- Number Per 100 Number Per 100 Lbs. (kg) I Lbs. (kg) T. _ 1/4"-20 Thread Size '/2"-13 Thread Size ''; If- ' ' '/aX'/zHHCS_ 1.0 (0.45) '/2X3/4HHCS_ 8.0 (3.63) 1/4X3/4HHCS_ 1.0 (0.45) '/2XIHHCS_ 9.0 (4.08) '/4X1 HHCS_ 2.0 (0.91) 1/2X1'/4HHCS_ 10.0 (4.45) '/4X1'/4HHCS_ 2.0 (0.91) '/2X1'/2HHCS_ 11.0 (4.99) L 1 '/4X1'/zHHCS 2.0 (0.91) 1/2X13/4HHCS_ 12.0 (5.44) ( r.,„ J '/4X13/4HHCS_ 3.0 (1.36) 1/zX2HHCS_ 114.0 (6.35) � 1/4X2HHCS 4.0 (1.81) 1/2X21/4HHCS_ 1 15.0 (6.80) 'H' '/4X2'hHHCS_ 4.0, (1.81) '/2X2'/2HHCS_ 116.0 (7.26) ® ` '/4X2%HHCS_ 4.0 (1.81) '/X23/4HHCS_ 18.0 (8.16) to .�..) �/�/ '/.X3HHCS_ 5.0 (2.27) '/2X3HHCS_ a 19.0 (8.62) 'i 6/,e"-18 Thread Size Y2X3'/4HHCS_ 20.0 (9.07) 5/,6X3/aHHCS_ 2.0 (0.91) '/ 3'/zHHCS_ 22.0` (9.98) 5/,6X1HHCS_ 3.0 (1.36) '/2X33/aHHCS_ 23.0 (10.43) Part Number Example 5/,6X1'/aHHCS_ 3.0 (1.36) '/2X4HHCS_ ' 25.0 (11.34) 'h x 2 HHCS YZ 5/+6X1'/2HHCS_ ; 4.0 (1.81) 1/2X41/2HHCS_ ! 27.0 (12.25) 5/,6X2HHCS_ 5.0 (2.27) 5/6"-11 Thread Size Thread Size 5A6X3HHCS_ 7.0 (3.17) %X3/4HHCS 1 13.0 (5.89) = 1/4 5/+6"-18 Thread Size 5/6X1HHCS_' 15.0 (6.80) 1/4 "-20 5/16= 5/16"-18 3 , %X1'/4HHCiS , 17.0 (7.71) /6X/2HHCS_ 4.0 (1.81) 3/a =3/8"-16 slsX3/aHHCS_ 4.0 (1.81) %XI' HHCS, 18.0 (8.16) 1/2 = '/z" 13 s 0 %X13/aHHCS_ 20.0 (9.07) /6X1HHCS_ 5.0 (2.27) /a= /e 6 6 -11 /s" 3 + %X2HHCS_ 22.0 (9.98) X1/aHHCS_ 5.0 (2.27) Length 3/6X1'/2HHCS_ 6.0 (2.72) 5X2'/4HHCS_ 24.0 (10.88) 'L' 3 3 %X2'/zHHCS 26.0 (11.79) /6X7/aHHCS_ 7.0 (3.17) 3/6X2HHCS_ 7.0 (3.17) %X23/4HHCS_ 28.0 (12.70) 3/sX21/4HHCS_ 8.0 (3.63) %X3HHCS_ 31.0 (14.06) Add Suffix_ %X2'/2HHCS_ 9.0 (4.08) %X3'/4HHCS_ 33.0 (14.97) YZN - Yellow Zinc 3/sX23/4HHCS_ 9.0 (4.08) %X3'/2HHCS_ 35.0 (15.87) SB - Silicon Bronze 5/6X33/4HHCS_ 37.0 (16.78) /6X3HHCS_ 10.0 (4.45) Y6X4HHCS_ 40.0 (18.14) %X5HHCS_ 48.0 (21.77) 364 B-Line series Server&Network Solutions www.eaton.com Mounting Hardware & Supports Hex Nuts F'B' .- 'C' • Material:ASTM A536 Gr.A steel. ASTM F468 silicon bronze • Finish:Yellow zinc(YZ) 0, Silicon Bronze(SB) Part Thread 'B' 'C' Weight Number Size Per 100 YZN Silicon Bronze In. (mm) In. (mm) Lbs. (kg) 12-24HNYZN 12-24HNSB #12-24 7/,s' (11.1) 5/3i' (3.9) I 1.0 (0.45)/4HNYZN YIHNSB 1/4"-20 7A6" (11.1) 7/32" (5.5) 1.0 (0.45) 5/16HNYZN 5/,6HNSB 5/,6"-18 1/2" (12.7) 17/64" (6.7) 1.0 (0.45) %HNYZN %HNSB 3/8"-16 9/16" (14.3) ( 21/64' (8.3) 2.0 (0.91) 1/2HNYZN 1/2HNSB 1/2"-13 3/4" (19.0) 7/6" (11.1) 6.0 (2.72) %HNYZN 5/sHNSB %"-11 15/16" (23.8) 35/64" (13.9) 7.0 (3.17) Flat Washer • Material:ASTM 844 steel. 651 alloy silicon bronze • Finish: Yellow zinc(YZ) A -- Silicon Bronze(SB) Part Thread 'A' 'B' ,C, Weight Number Size Per 100 YZN Silicon Bronze In. (mm) In. (mm) In. (mm) Lbs. (kg) 12FWYZN - #12-24 1/4" (6.3) 9/16" (14.3) 3/64" (1.19) 0.30 (0.13) 1/aFWYZN 1/4FWSB 1/4"-20 5/6" (7.9) 3/4" (19.0) 1/16" (1.591 0.40 (0.18) 5/16FWYZN 5/16FWSB 5/i6"-18 3/8' (9.5) 3/4" (19.0) 5/64' (1.98) 1.20 (0.54) 3/sFWYZN 3/sFWS6 3/8"-16 As" {11.1) 1" (25.4) 5/64" (1.98) 1.60 (0.72) 1/2FWYZN Y2FWSB 1/2"-13 5/6" (14.3) 1%" (34.9) 7/64" (2.78) 4.10 (1.86) 5/8FWYZN g%s"-11 11/,6" (17.4) 13/4" (44.4) Ve.4" (3.57) 7.30 (3.31) - B-Line series Server&Network Solutions www.eaton.com 365 Mounting Hardware & Supports Lock Washer • Material:ANSI 18.21.1 steel. 651 alloy silicon bronze B • Finish:Yellow zinc(YZ) 'C' Silicon Bronze (SB) Part ', Thread 'B' 'C' Weight Number Size Per 100 YZN Silicon Bronze In. (mm) In. (mm) Lbs. (kg) 10LWSB #10-24 21/64" (8.2) .05" (1.3) 0.1 (0.04) '/4LWYZN 'LWSB 1/4"-20 1%2" (11.9) .05" (1.3) 3.0 (1.36) 5/,sLWYZN 5/16LWSB 5A6"-18 1%2" (15.1) .09 (2.3) 4.0 (1.81) %LWYZN %LWSB %'-16 11/16" (17.4) .10" (2.5) 6.0 (2.72) '/zLWYZN '/2LWSB 1/2"-13 7/8" (22.2) .13" (3.3) ! 13.0 (5.89) %LWYZN — 5/8"-11 13/32" (27.8) .17" (4.3) 25.0 (11.34) Two Hole Plate 'E' • Material:ASTM A36 structural steel • Finish:Yellow zinc(YZ) max. 'F' Part Number 'A' 'B' 'C' 'D' 'E' •L" Weight In. (mm) In. (mm) In. (mm) In. (mm) In. (mm) In. (mm) Lbs. (kg) SB21501 35/8" (92) 27/16" (62) 7A6" (11) 2" (51) 3A6" (5) 11/4" (32) 0.25 (0.11) SB21502 393/16" (97)` ' 25/8" (66) 9/16" (14) 21/A6" (52) 3/6'` (5) 11/4" (32) 0.25 (0.11) SB21503 31/4" (82) 21/16" (52) 9/16" (14) 11/2" (38) 3/16" (5) 11/4" (32) 0.20 (0.09) SB21504 33/4 (95) 29/%6" (65) 3/6" (9) 23/A6"' (55) 3/16" (5) 11/4" (32) 0.20 (0.09) SB21505 31/2" (89) I 27/16" (62) 3/8" (9) 21/6" (52) 3/16" (5) 11/4" (32) 0.20 (0.09) SB21506 51/8" (130) 43/s' (111) 3/8" (9)., 4" (101) , 1/4" (6) 11/4 (32)' i 0.35 (0.16) SB21507 63/4" (171) 53/4" (146) 9/16" (14) 53/16" (132) 3/8" (9) 2" (51) 1.40 (0.63) i I Touch-Up Paint Part Color Qty./Box Wt./Box • Size: 0.6 ounce bottle Number ozs. (liter) • Brush on SB420CFB Flat Black Lacquer 1 0.6 (0.18) SB420CTG Gray Lacquer 1 0.6 (0.18) 366 B-Line series Server&Network Solutions www.eaton.com Mounting Hardware & Supports Stand-Off Isolator • Use to electrically isolate copper ground bus • UL recognized material • UL 94 VO flame resistance • Material: Polyester fiberglass with steel threaded inserts • Finish color: Red • Tensile pull-out strength: 2300 lbs. (10.23kN) • Cantilever strength: 2800 in./lbs. (316Nm) • Dielectric strength: 19000-21000 volt S.T. Part Thread 'L' Weight Number Size In. (mm) Lbs. (kg) SB1155 3/8"-16 21/2" (63) 0.30 (0.13) SB1156 W-13 21/2" (63) 0.31 (0.14) SB1157 5/8"-11 25/8" (66) 0.39 (0.17) 1" (25mm) Stand-Off Isolator • Use to secure and electrically isolate copper ground bus to equipment frame • Includes: (1) Isolator, (2 each) hex head cap screws and lock washers • UL recognized material • UL 94 VO flame resistance • Material: Polyester fiberglass with steel threaded inserts • Finish color: Red • Tensile pull-out strength: 900 lbs. (4.00kN) MDF or Relay Rack Upright • Cantilever strength: 350 in./lbs. (39.5Nm) Copper • Dielectric strength: 10000 volt S.T. minimum Ground Bus 00 1" "C (25mm) , reo f� Isolator Part Thread Weight HHCS Number Size Lbs. (kg) SB1154 1/4"-20 0.09 (0.04) Lockwasher SB1153 #12-24 0.09 , (0.04) B-Line series Server&Network Solutions www.eaton.com 367 Mounting Hardware & Supports Two-Hole Isolation Pad • Use to provide electrical isolation between metallic fittings • See SB-2531 for kit 'D' • UL recognized material A' • UL 94 VO flame resistance B • Material: 1/16" (1.6mm)polyester fiberglass • Finish Color: Red 'C' Hole Dia. Part 'A' 'B. ,C, ,D. ,E, Hole Weight Number Diameter In. (mm) In. (mm) In. (mm) In. (mm) In. (mm) In. (mm) Lbs. (kg) SB116301 47/6" (112) 27/6" (62) 1" (25) 21/2" (54) 11/6" (27) 3/e" (9) 0.04 (0.02) SB116302 31/2" (89) 11/2" (38) 1' (25) 21A" (54) 1'/6"; (27) a/a" (19) 0.03 (0.01) SB116303 65/s" (168) 4%" (117) 1" (25) 21/4" (54) 1'/16" (27) 11/16" (17) 0.06 (0.03) S13116304 45/e" (117) 25/8" (66) 1" (25) 21/s" (54) 1'/16" (27) 9/is" (14) 0.04 (0.02) SB116305 49/is" (116) 29/is" (65) 1" (25) 23/4" (70) 2%2" (58) 3/s" (9) 0.06 (0.03) SB116306 4/" (105) 2'/e" (54) 1" (25) 2'/e" (54) 11/16 (27) 9/16" (14) - 0.04 10.02) SB116307 73/4" (197) 53/4" (146) 1" (25) 2%' (67) 15/is" (33) %" (16) 0.09 (0.04) SB116308 49/is" (116) 29/16" (65) 1" (25) I 73/4" (197) 29/a2"', (58) G s/s" (9) 0.16 (0.07) SB116309 91/8" (232) 2%" (67) 1" (25) 21/2" (54) 11/16" (27) 9/6" (14) 0.09 (0.04) Single-Hole Isolation Pad • Use to provide electrical isolation between metallic fittings 27/1s 2'/e • See SB-2501 for kit (62mm) (54mm) • UL recognized material • UL 94 VO flame resistance / • Material: '/1s" (1.6mm) polyester fiberglass • Finish Color: Red 3/a" Hole (9mm) Part Weight Number Lbs. (kg) SB1162 0.03 (0.01) 368 B-Line series Server&Network Solutions www.eaton.com Mounting Hardware & Supports Nylon Headed Sleeve Kit(Sleeve Washer Included) • Use to provide electrical isolation when using metallic i fasteners 1 ` Gx • Material: 6/6 Nylon —44 — 'A' 'C' • Finish: Natural _ I• 'B' 1.1 (1.6mm) Part Used With 'A' 'B' ,C, Weight Number Bolt Size In. (mm) In. (mm) ! In. (mm) Lbs. (kg) SB114502 5/6"-18 .356" (0.16) 1/4" (6) 3/4" (19) 0.001 (0.0004) SB114504 5/t6"-18 .356" (0.16) 1/2" (13) 3/4" (19) 0.001 (0.0004) SB114518 5/is"-18 .356" (0.16) 25/6" (59) 3/4" (19) 0.003 (0.0013) SB114602 3/s"-16 .419" (0.19) 1/4" (6) 7/a" (22) 0.001 (0.0004) SB114605 3/s"-16 .419" (0.19) 5/s" (16) 7/8" (22) 0.001 (0.0004) SB114707 1/2"-13 .548" (0.25) 7/a" (22) 1" (25) 0.001 (0.0004) SB114718 1h"-13 .548" (0.25) 25/s" (59) 1" (25) 0.005 (0.0022) SB114807 5/s"-11 .680" (0.31) 7/a" (22) 11/4" (32) 0.002 (0.0009) SB114818 %"-11 .680" (0.31) j 25/is" (59) 11/4" (32) 0.006 (0.0027) Screws&Cage Nuts • All part numbers are packaged and sold in bags of 100 pieces. Cage Nuts Screws Weight Part Number Description Finish Each lbs. (kg) E2MA1032PHMS100 #10-32 Phillips Clear Zinc 0.1 (0.04) Screws E2MA1224PHMS100 #12-24 Phillips Clear Zinc 0.1 (0.04) E2MAM6PHMS100 M6 Phillips Yellow Zinc 0.1 (0.04) E2MACN1032100 ` i #10-32 Phillips Clear Zinc 0.1 (0.04) Cage Nuts E2MACN1224100 #12-24 Phillips Clear Zinc 0.1 (0.04) E2MACNM6100 , M6 Phillips Yellow Zinc 1 0.1 (0.04) Hardware Rackstuds' tool-less mounting kit Part number Description RSSTUD- Pkg.of 100 KIT100 6-Line series Server&Network Solutions www.eaton.com 369 Mounting Hardware & Supports Nylon Fasteners • Sold in packages of 100 pcs • Material: 6/6 Nylon >I• Finish: Natural Pan Head Machine Screw Part Thread 'L' 'W' Weight Number 1 Size r Per 100 In. (mm) In. (mm) Lbs. (kg) 12-24X1SPHMSNYL #12"-24 1" (25) 27/e4" (11) 0.2 (0.09) Hex Head Cap Screw ` j ;.\ (I ( (\ \�1�111 Part Thread 'L' 'W' Weight li1�1'1'k�ll)114+1'�p��11 �11IG Number Size Per 100 ,W, �— 'L' .1 In. (mm) In. (mm) Lbs. (kg) 1 3 i 1 3 ' /aX/aHHCSNYL /a"-20 /a" (6) /s' (9) 0.2 (0.09) 1/4X1HHCSNYL" '/4"-20 1" (25) 1' 3/s" (9) 0.3 (0.13) 1/4X1'/2HHCSNYL 1/4"-20 11/2' (38) 3/s" (9) 0.3 (0.13) 5/IsX1HHCSNYL 5/1s"-18 1" (25) 7/16" (11) 0.4 (0.18) Hex Nut ram. Part Thread 'H' 'W' Weight till\ Number Size Per 100 A ►jr 'H' In. (mm) In. (mm) Lbs. (kg) i 12HNNYL #12"-24 5/32" (4) 7/16" (11) 0.1 (0.04) 'AHNNYL 1/4"-20 7/32" (5) 7/is" (11) 0.1 (0.04) 5/,eHNNYL 5/16"-18 7/64" (7) 1/2" (13) 0.2 (0.09) ,W, 1' Flat Washer Part For 'D' 'W' Weight f Number Bolt Size Per 100 ,W, In. (mm) In. (mm) Lbs. (kg) II 12FWNYL l #12 1/4" (6.3) 9/1a" (14) 0.1 (0.04) 'AFWNYL 1/a" 5/16" (7.9) 11/ie' (17) 0.1 (0.04) � 5 5.... 3/6" (9.5) 3/4" (19) 0.1 (0.04) 1/16" /�eFWNYL /is" � (1.6mm) %FWNYL 3/a" 7/1e" (11.1) 7/8" (22) 0.1 (0.04) I i I a,,, ,, 370 B-Line series Server&Network Solutions www.eaton.com Seismic Bracing ' Fig. 4L- Longitudinal In-Line Sway Brace Attachment Size Range: 21/2" (65mm)through 8" (200mm) IPS. Material: Steel APPROVED Function: For bracing pipe against sway and seismic disturbance. Set Bolt&Hardware Included Approvals: Approved by Factory Mutual Engineering (FM), 21/2"(65mm) $�, through 8" (200mm) pipe. ,.:, For UL Listed information refer to page 50. ,�7 = Installation Instructions: Fig. 4L is the"braced pipe" attachment component of a longitudinal sway brace assembly. It is intended to be A combined with the "bracing pipe"and TOLCO structural attachment component to form a complete bracing assembly. NFPA 13 and/or FM guidelines should be followed. To Install: Place the Fig. 4L over the pipe to be braced and tighten D bolts.Then engage "bracing pipe" into jaw opening and tighten set bolt until head snaps off. Jaw attachment can pivot for adjustment to proper brace angle. Finish: Plain. Contact B-Line for alternative finishes and materials. c :11 Order By: Figure number, pipe size and finish. Designed to meet or exceed requirements of FM DS 2-8. ►.. • /. 11111 4-Way Riser Brace (plan view) Longitudinal Brace Pipe Max.Rec.Load(FM) Approx. Part Size A C D Bolt Size 30°-44° 45°-59° 60°-74° 75°-90° Wt./100 No. in. (mm) in. (mm) in. (mm) in. (mm) lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kg) 41-21/2 21/2" (65) 67/l6" (163.5) 21/2"'°(63.5) 23/4" (69.8) 1/2"-13 1030 (4.58) 1180 (5.24) 1420 (6.31) 1590 (7.07) 253 (114.7) 41-3 3" (80) 7" (177.8) 23/4" (69.8) 31/16" (77.8) 1/2"-13 1030 (4.58) 1180 (5.24) 1420 (6.31) 1590 (7.07) 268 (121.5) 4L-4 4" (100) 81/2" (215.9) 33/8" (85.7) 311/16"(93.7) 1/2"-13 530 (2.36) 730 (3.25) 890 (3.96) 990 (4.40) 348 (157.8) 41-5 5" (125) 93/4" (247.6) 37/8" (98.4) 43/8" (111.1) 1/2"-13 530 (2.36) 730 (3.25) 890 (3.96) 990 (4.40) 380 (172.3) 41-6 6" (150) 111/2" (292.1) 5" (127.0) 51/8' (130.2) 1/2"-13 530 (2.36) 730 (3.25) 890 (3.96) 990 (4.40) 640 (290.3) 41-8 8" (200) 131/4" (336.5) 55/8"(142.8) 55/8" (142.9) 1/2"-13 490 (2.18) 680 (3.02) 830 (3.69) 930 (4.131 728 (330.2) FM Approved when used with 1', 11/4", 11/2" or 2" Sch. 40 brace pipe. FM Approved design loads are based on ASD design method. Eaton's B-Line Business seismic bracing components are designed to be compatible only with other B-Line bracing components, resulting in a listed seismic bracing assembly. B-Line's warranty for seismic bracing components will be the warranty provided in B-Line's standard terms and conditions of sale made available by B-Line, except that, in addition to the other exclusions from B-Line's warranty, Eaton's B-line Business makes no warranty relating to B-Line's seismic bracing components that are combined with products not provided by Eaton's B-Line Business. All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line L Fire Protection Solutions 51 by E 1.H ' Seismic Bracing Fig.4LA- In-Line Sway Brace Attachment (t) CCT Size Range: 1"(25mm)through 12"(300mm) IPS. Material: Steel Function: For bracing pipe against sway and seismic disturbance. Approvals: �� For FM Approval information refer to page 53. *' �j,.\ Alij Installation Instructions: Fig.4LA can be used as the system attachment , '.��I'I component of a longitudinal or lateral brace assembly. It is intended to be ` combined with the"bracing member and TOLCO transitional attachment 1 c and structural attachment to form a complete bracing assembly. For fire A sprinkler applications NFPA 13 guidelines should be followed. T. w k C To Install: Place the Fig.4LA pipe clamp component over the pipe to be r +,,ji___J braced and tighten down the break-off nuts until the hex head portion breaks off to verify correct installation torque. Next engage brace member(pipe or 4LA-1 thru 4LA-4 strut)with jaw component and tighten break-off head bolt until the hex head breaks off to verify correct installation torque. Pivot jaw for correct angle and attach to structure using TOLCO brand transitional 6- attachment and structural attachment. C` Finish: Plain or Electro-Galvanized. Contact B-Line for % alternative finishes and materials. y, :�■ dt Order By: Figure number, pipe size and finish. .y Longitudinal Brace 2F " C • Lateral r:., r - ;A,, Brace Oa k_---- -- 4LA-5 thru 4LA-12 Pipe Max.Rec.Load Approx. Part Size A C D Bolt Size Longitudinal&Lateral Wt./100 No. in. (mm) in. (mm) in. (mm► in. (mm) lbs. (kN) lbs. (kg) 4LA-1 ' 1" (25) 319/32" (91.2) 15/is" (33.5) 15/16" (33.5) 3/8"-16 1000 (4.45) 119 (54.0) 4LA-11/4 11/4" (32) 329/32" (99.3) 13/8" (35.3) 13/8" (35.3) 3/8"-16 1000 (4.45) 123 (55.8) 4LA-11/2 11/2" (40) 45/32" (105.7) 11/2" (38.5) 11/2" (38.5) 3/8"-16 1000 (4.45) ` 127 (57.6) 4LA-2 2" (50) 511/32" (135.6) 21/32" (51.9) 21/16" (51.9) 3/8"-16 1000 (4.45) 142 (64.4) 4LA-21/2 21/2" (65) 527/32 (148.7) 25/16" (58.5) 25/16" (58.5) 3/8"-16 1000 14.45) 173 (78.5) 4LA-3 3" (80) 61/2" (164.9) 25/8" (66.6) 25/8" (66.6) 3/8"-16 1000 (4.45) 187 (84.8) 41.A-31/2 31/2" (90) 7.407" (188.1) 27/8" (73.1) 27/8" (73.1) 3/8"-16 1000 (4.45) 198 (89.81 4LA-4 4" (100) 713/32" (190.8) 31/8" (79.5) 31/8" (79.5) 3/8"-16 1000 (4.45) 209 (94.8) 4LA-5 5" (125) 83/4"`(222.3) 35/8" (92.1) 35/8" (92.1) 1/2"-13 1600 (7.12) 298 (135.2) 4LA-6 6" (150) 105/8" (269.9) 49/16"(115.9) 49/16" (115.9) 1/2"-13 1600 (7.12) 521 (236.3) 2132" 1437 12"4LA$ 8" (200) 1213/16"'(325.5) 59/16"(143.7) 5 / ) / 13 2015 (7.12) 629 (285.3) 4LA-10 10" (250) 161/2" (419.1) 71/4" (184.2) 71/4" (184.2) 1/2"-13 2765 (8.96) 1320 (598.7) 4LA-12 12" (300) 181/2" (469.9) 81/4";(209.6) 81/4" (209.6) 1/2"-13 -- 1496 (678.6) Eaton's B-Line Business seismic bracing components are designed to be compatible only with other B-Line bracing components, resulting in a listed seismic bracing assembly. B-Line's warranty for seismic bracing components will be the warranty provided in B-Line's standard terms and conditions of sale made available by B-Line,except that, in addition to the other exclusions from B-Line's warranty, Eaton's B-line Business makes no warranty relating to B-Line's seismic bracing components that are combined with products not provided by Eaton's B-Line Business. All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line by 6.T•N 52 Fire Protection Solutions Seismic Bracing A Fig.4LA- In-Line Sway Brace Attachment Size Range: 1"(25mm)through 12"(300mm) IPS. 44(1::)° Material: Steel APPROVED Function: For bracing pipe against sway and seismic disturbance. - r9" Approvals: Approved by Factory Mutual Engineering(FM), 1"(25mm)through ",►,f`a " N. . .. 12"(300mm)pipe. Installation Instructions: Fig.4LA can be used as the system attachment component of a longitudinal or lateral brace assembly. It is intended to be ,,-. " u A combined with the"bracing member and TOLCO transitional attachment , �, _" and structural attachment to form a complete bracing assembly. For fire c sprinkler applications NFPA 13 guidelines should be followed. :. 1 To Install: Place the Fig.4LA pipe clamp component over the pipe to be braced and tighten down the break-off nuts until the hex head portion 4LA-1 thru 4LA-4 breaks off to verify correct installation torque. Next engage brace member *` (pipe or strut) with jaw component and tighten break-off head bolt �„ until the hex head breaks off to verify correct installation torque. Pivot jaw 4 for correct angle and attach to structure using TOLCO brand transitional ,'" e�0 attachment and structural attachment. d Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and materials. Order By: Figure number, pipe size and finish. o A .': ate 4.441. Brace . f' Lateral , A Brace 4LA-5 thru 4LA-12 Pipe FM Max.Rec.Load Approx. Longitudinal&Lateral** Part Size A C D Bolt Size 30°-44° 45°-59° 60°-74° 15°-90° Wt./100 No. in. (mm) in. (mm) in. (mm) in. (mm) lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kg) 4LA-1 1" (25) 319/32" (91.2) 15/16" (33.5) 15/16" 133.5) 3/8"-16 680 (3.02) 970 (4.31) 1190 (5.29) 1320 (5.87) 119 (54.0) 4LA-11/4 11/4" (32) 329/32" (99.3) 13/8" (35.3) 13/8" (35.3) 3/8"-16 680 (3.02) 970 (4.31) 1190 (5.29) 1320 (5.87) 123 (55.8) 4LA-11/2 11/2" (40) 45/32" (105.7) 11/2" (38.5) 11/2" (38.5) 3/80-16 680 (3.02) 970 (4.31) 1190 (5.29) 1320 (5.87) 127 157.6) 4LA-2 2" (50) 511/32" (135.6) 21/32" (51.9) 21/16" (51.9) 3/8"-16 680 (3.02) 970 (4.31) 1190 (5.29) 1320 (5.87) 142 (64.4) 4LA-21/2 21/2" (65) 527/32" (148.7) 25/16". (58.5) ; 25/16" (58.5) 3/8"-16 680 (3.02) 970 (4.31) 1190 (5.29) 1320 (5.87) 173 (78.5) 4LA-3 3" (80) 61/2" (164.9) 25/8" (66.6) 25/8" (66.6) 3/8"-16 680 (3.02) 970 (4.31) 1190 (5.29) 1320 (5.87) 187 (84.8) 4LA-31/2 31/2" (90) 7.407" (188.1) 27/8" (73.1) 27/8" (73.1) 3/8"-16 680 (3.02) 970 (4.31) 1190 15.29) 1320 (5.87) 198 (89.8) 4LA-4 4" (100) 713/32" (190.8) 31/8" (79.5) 31/8" (79.5) 3/8"-16 680 (3.02) 970 (4.31) 1190 (5.29) 1320 (5.87) 209 (94.8) 41A-5 5" (125) 83/4" (222.3) 35/8'; (92.1) 35/8' (92.1) 1/2"-13 680 (3.021 970 (4.31) 1190 (5.29) 1320 (5.87) 298 (135.2) 4LA-6 6" (150) 105/8" (269.9) 49/16" (115.9) 49/16" (115.9) 1/2"-13 1620 (7.20) Note 1 Note 3 Note 5 521 (236.3) 4LA-8 8 (200) 1213/16"(325.5) 59/16" (143.7) 5�1/32"(143.71 1/7-13 1620 (7.20) Note 2 Note 4 Note 6 629 (285.3) 4LA-10 10" (250) 161/2" (419.1) 71/4" (184.2) 71/4" (184.2) 1/2'-13 1620 (7.20) Note 2 Note 4 Note 6 1320 (598.7) 4LA-12 12" (300) 181/2" (469.9) 81/4" (209.6) 81/4" (209.6) 1/2"-13 1620 (7.20) Note 2 Note 4 Note 6 1496 1678.6) ** Longitudinal and Lateral Loads are the same except where noted in chart. Note 1: Longitudinal Load 2260 lbs. (10.05kN) - Lateral Load 2300 lbs. (10.23kN) Note 2: Longitudinal Load 1660 lbs. (7.38kN) - Lateral Load 2300 lbs. (10.23kN) Note 3: Longitudinal Load 2010 lbs. (8.94kN) - Lateral Load 2820 lbs. (12.54kN) Note 4: Longitudinal Load 1570 lbs. (6.98kN) - Lateral Load 2820 lbs. (12.54kN) Note 5: Longitudinal Load 2220 lbs. (9.87kN) - Lateral Load 3140 lbs. (13.96kN) Note 6: Longitudinal Load 1740 lbs. (7.74kN) - Lateral Load 3140 lbs. (13.96kN) Eaton's B-Line Business seismic bracing components are designed to be compatible only with other B-Line bracing components, resulting in a listed seismic bracing assembly. B-Line's warranty for seismic bracing components will be the warranty provided in B-Line's standard terms and conditions of sale made available by B-Line,except that,in addition to the other exclusions from B-Line's warranty, Eaton's B-line Business makes no warranty relating to B-Line's seismic bracing components that are combined with products not provided by Eaton's B-Line Business. All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. ■ B-Line Fire Protection Solutions 53 by E:T•N Seismic Bracing Fig. 980 - Universal Swivel Sway Brace Attachment-3/8" to 3/4" ® " Y Size Range: One size fits bracing pipe 1"(25mm)thru 2" (50mm), B-Line APPROVED 12 gauge (2.6mm)channel, and all structural steel up to 1/4"(31.7mm)thick. Material: Steel Function: Multi-functional attachment to structure or braced pipe fitting. 6.64-% Features: This product's design incorporates a concentric attachment 1 opening which is critical to the performance of structural seismic connections. � °.\ D NFPA 13 indicates clearly that fastener table load values are based only on concentric loading. Mounts to any surface angle. Break off bolt head assures verification of proper installation. A Installation: Fig.980 is the structural or transitional attachment component ' ..,/ B of a longitudinal or lateral sway brace assembly. It is intended to be combined with the "bracing pipe"and TOLCO "braced pipe"attachment, Fig. 1000, 1001, Set Bolt 4L, or other TOLCO approved attachment to pipe to form a complete bracing Included assembly. NFPA 13 guidelines should be followed. Mounting Hardware Is Not Included To Install: Place the Fig. 980 onto the "bracing pipe". Tighten the set bolt until the head breaks off. Attachment can pivot for adjustment to proper brace angle. Approvals:—Approved by Factory Mutual Engineering (FM). For UL Listed information refer to page 66. 1M Note: Fig. 980 Swivel Attachment and Fig. 1000, 1001, 4L or other TOLCO , s't approved attachment to pipe that make up a sway brace system of UL Listed . attachments and bracing materials which satisfies the requirements of Underwriters Laboratories and the National Fire Protection Association (NFPA) *.•., .k,. :'`- P. Finish: Plain, Electro-Galvanized or Stainless Steel. Contact B-Line for alternative finishes. Order By: Figure number and finish. lir— Fig.980 Pat.#6,273,372,Pat.#6,517,030,Pat.#6,953,174, • Pat.#6,708,930,Pat.#7,191,987,Pat.#7,441,730, Pat.#7,669,806 • /11,1 Designed to meet or exceed requirements of FM DS 2-8. Fig.4L J. Lateral Bracei_l Longitudinal Brace Part Mtg.Hdw. Mounting Hole ' Max.Design Load**(FM) Approx. Number Size A B D 30°-44° 45°-59° 60°-74° 75°-90° Wt./100 in. (mm) in. (mm) in. (mm) in. (mm) i lbs./(kN) lbs./(kN) lbs./(kN) lbs./(kN) lbs. (kg) 980-3/8 3/8" (9.5) 51/4"(133.3) 17/8'. (47.6) 13/32"110.3) 149 (67.6) 980-1/2* 1/2"(12.7) 51/4"(133.3) 17/8" (47.6) 17/32"(13.5) ( 1320 1970 2310 2550 148 (67.1) 980-5/8 5/8"(15.9) 51/4"(133.3) 17/8" (47. ) 11/16"(17.5) (5.87) (8.76) (10.27) (11.34) 147 (66.7) 980-3/4 3/4"(19.0) 51/4"(133.3) 17/8" (47.6) 13/16"(20.5) i 146 (66.2) * Standard size. ** Installed with 1" or 11/4" Schedule 40 brace pipe. FM Approved design loads are based on ASD design method. Eaton's B-Line Business seismic bracing components are designed to be compatible only with other B-Line bracing components, resulting in a listed seismic bracing assembly. B-Line's warranty for seismic bracing components will be the warranty provided in B-Line's standard terms and conditions of sale made available by B-Line, except that, in addition to the other exclusions from B-Line's warranty, Eaton's B-line Business makes no warranty relating to B-Line's seismic bracing components that are combined with products not provided by Eaton's B-Line Business. All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line Fire Protection Solutions 67 by EZ•N Seismic Bracing ` TOLCO Fig. 1001 - sway brace attachment (FM approved) Size Range: Pipe size to be braced: 1" (25mm)thru 8" (200mm) IPS. Pipe size used OPM igi> for bracing: 1" (25mm)and 11/4" (32mm)Schedule 40 IPS. APPROVED Material: Steel a Function: For bracing pipe against sway and seismic disturbance..The pipe c attachment component of a sway brace system: Fig. 1001 is used in conjunction m with a Fig. 900 Series fitting and joined together with bracing pipe per NFPA 13, 0 forming a complete sway brace assembly. E so Features: Can be used to brace schedule 7 through schedule 40 IPS. Field 4n adjustable, making critical pre-engineering of bracing pipe length unnecessary. Unique design requires no threading of bracing pipe. Can be used as a component of a four-way riser brace. Comes assembled and ready for installation. Fig. 1001 r* has built-in visual verification of correct installation. See installation note below. \1 Installation Note: Position Fig. 1001 over the pipe to be braced and tighten two \� hex head cone point set bolts until heads bottom out. A minimum of 1" (25mm) Set Bolts pipe extension is recommended. Brace pipe can be installed on top or bottom of Included pipe to be braced. 1 Approvals: Approved by Factory Mutual Engineering (FM). Included in our Seismic Engineering Guidelines approved by the State of California Office of Statewide Health Planning and Development(OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to our Seismic Engineering Guidelines, OPM-0052-13. For UL Listed information refer to UL Listed page 66. ; Finish: Plain, Electro-Galvanized or Hot Dip Galvanized. Contact customer service ' for alternative finishes and materials. Order By: Order by figure number, pipe size to be braced, followed by pipe size used for bracing (1"(25mm)or 11/4" (32mm)) , and finish. Important Note: Fig. 1001 is precision manufactured to perform its function as a critical component of a complete bracing assembly.To ensure performance, the FM Approval requires that Fig. 1001 must be used only with other TOLCO'" x:>4► bracing products.The Fig. 1001 is not intended for use with the Fig. 907 r 4-way Longitudinal Brace Attachment. Designed to meet or exceed requirements of FM DS 2-8. Design Load-For Sch.7,Sch.10,&Sch.40 Pipe Pipe Part Number&Approx.Wt./100 Allowable Horizontal Capacity(Ibf)Per Installation'•''' Size 1"(25mm)Brace Pipe 1'/4")32mm►Brace Pipe 30°-44° 45°-59° 60°-74° 75°-90° in. (mm) li Lbs. (kg) Lbs. (kg) Lbs. (kN) Lbs. (kN) Lbs. (kN) Lbs. (kN) 1" (25) 1001-1 X 1 104.6 (47.4) 1001-1 X 11/4 122.2 (55.4) 1800 (8.01) 2550 (11.34) 3120 (13.88) 3490 (15.52) 11/4"(32) 1001-11/4 X 1 105.2 (47.71 1001-1'/4 X 1'/4 122.6 (55.6) 1230 (5.47) 1740 (7.74) 2140 (9.52) 2380 (10.59) 11/2"(40) ( 1001-11/2 X 1 107.0 (48.5) 1001-11/2 X 11/4 124.7 (56.6) 1230 (5.47) 1740 (7.74) 2140 (9.52) 2380 (10.59) 2" (50) 1001-2 X 1 112.6 (51.1) 1001-2 X 1'/4 129.2 (58.6) 1230 (5.47) 1740 (7.74) 2140 (9.52) 2380 (10.59) *21/'1651 1001-21/2 X 1* 136.3 (61.8) j 1001-2'/2 X 11/4* 154.4 (70.0) 800 (3.56) 1130 (5.03) 1380 (6.14) 1540 (6.85) 3" (80) 1001-3 X 1 145.0 (65.8) !: 1001-3 X 1'/4 163.1 (74.01 850 (3.78) 1200 (5.34) 1470 (6.541 1640 (7.30) 4" (100) i 1001-4 X 1 158.6 (71.9) 1001-4 X 1'/4 176.7 (80.1) 850 (3.78) 1200 (5.34) 1470 (6.54) 1640 (7.30) 5" (100) 1001-5 X 1 173.2 (78.6) ! 1001-5 X 11/4 191.4 (86.8) 510 (2.27) 730 (3.25) 890 (3.96) 990 (4.40) *6"(150) 1001-6 X 1* 190,0 (85.21 1001-6 X 11/4* 206.0 (93.4) 510 12.27) 730 (3.25) 890 (3.96) 990 (4.40) *8"(200) 1001-8 X 1* 217.4 (111.5) 1001-8 X 11/4* 265.3 (120.3) ( 510 (2.27) 730 (3.25) 890 (3.961 990 (4.401 FM Approved when used with 1 or 174 inch NPS Schedule 40 GB/T 3091,EN 10255H,or JIS G3451 steel pipe as the brace member. Load rating for LW above refers to FM Approved Lightwall Pipe commonly referred to as "Schedule 7".These ratings may also be applied when EN 10220 and GB/T 8163 steel pipe. Load rating for Schedule 10 above may be applied to GB/T 3092,EN 10255M and H,or JIS G3454, FM Approved Thinwall,or Schedule 40 steel pipes. Note: See UL load ratings in UL Listed Design tLoad chart shown under drawing. 0. ���� *Note: Metric sizes available for 65mm, 150mm,200mm ' �` ® 111,_111111 as pipe size with 25mm and 32mm brace pipe size. .�" �r tliti n11 Contact the factory. %J Fig.1001 .,,. -- All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Fire Protection Solutions 67 Eaton Seismic Bracing TOLCO Fig. 906 - sway brace multi-fastener adapter Material: Steel ppM C (120US LISTED Allows sway brace fittings to develop greater load carrying ability by providing multiple fastener attachments for steel and wood.The National Fire Protection (NFPA) provides information on fastener loads to various structures. Refer to NFPA 13 (2016) 9.3.5.9.1. Approvals: Underwriters Laboratories Listed in the USA Hi (UL)and Canada (cUL)only when used with TOLCO' Fig. 900 Series Earthquake Brace Attachments. Included in our Seismic Engineering Guidelines approved by the State of California B J Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to our Htj0' Seismic Engineering Guidelines, OPM-0052-13. D Installation Instructions: Fig. 906 is a multiple fastener ► .. structural attachment component of a longitudinal or lateral C I J H2 sway brace assembly. It is intended to be combined with a TOLCO transitional attachment, "bracing pipe" and a TOLCO A "braced pipe" attachment to form a complete bracing "", assembly. NFPA 13 guidelines should be followed. Mounting Hardware To Install: Attach the Fig. 906 to the structural surface as Is Not Included per fastener design guidelines.Attach other TOLCO transitional attachment fitting, Fig. 980, 910, 909, or any other TOLCO approved transitional fitting.Transitional fitting attachment can pivot for adjustment to proper brace angle. Finish: Plain or Electro-Galvanized. Contact customer service for alternative finishes and materials. ,tt Order By: Figure number and specify dimensions H1 and H2. • Part A B C D H1 H2 Approx.Wt./100 Number in. (mm) in. (mm) in. (mm) in. (mm) Lbs. (kg) 906 12" (305.0) 9" (228.6) 2.5"(63.5) '/4' (6:3) Specify Specify 394 (178.7)' 906-12 15" (381.0) 12" (304.8) 2.5"(63.5) 1/4' (6.3) Specify Specify 494 (224.1) Load Note: Actual design load determined by anchor and concrete strength, not to exceed the UL Listed maximum load of 1200 lbs (5.33kN). Load is for Fig. 906. If combined load of anchors is less, must reduce to anchor maximum capacity. Eaton's B-Line series seismic bracing components are designed to be compatible only with other B-Line series bracing components, resulting in a listed seismic bracing assembly. Eaton B-Line Division warranty for seismic bracing components will be the warranty provided in Eaton B-Line Division standard terms and conditions of sale made available by Eaton, except that, in addition to the other exclusions from Eaton B-Line Division warranty, Eaton makes no warranty relating to B-Line series seismic bracing components that are combined with products not provided by Eaton. All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Fire Protection Solutions 57 Eaton . 4 .44,,, IVED .M '' 023 ,: ,, .., ., �,,e . ," �t • { ' \.: I / 7 4 .,.. „,..„,.. , Western States 't ',0 _.... ,00 ,,,,,,,, .., ,, ,. ,,, ��, t ,. , t. . ' Fire Protection Co. *° ; i; ;-` P s IP --LA., . ptuii,,,eetc,49.---- --'' . 0.41,7,, et4tee Pireftertet POWERED BY API GROUP FIRE PROTECTION TECHNICAL DATA SUBMITTAL Port Plastics fie` 7500 SW Tech Center Dr. #100 Portland, OR 97223 0 WSFP Project # LC0917 Prepared By: Alexander Funk Western States Fire Protection ���sp PROFESS 17500 SW 65th Avenue ��,c' �,‘6 t NFF� off cr 80861 PE r Lake Oswego, OR 97035 Digitally signed by Brandon Koonz OREGON e� Phone: 503.657.5155 ''sipy 9'?• /2 ti �4\' NC • \ Email: Alexander.Funk@wsfp.us wsfp.us EXPIRES:6/30/2025 w++rw+tirt3aaw iat e� `' '�,4 40 \'.,t...'"':'114/s-- ,,,,,,, ,....,„,,,,,,...Q.....,,, ,,,, . ,..g4--., ' -a,,4.4 i R 5. W _ '.0 -1,, S ,(..0... :,-. ‘le i Ipt ¢r ' 'e � b. _ ^e w .-.'.,..,, ..,4-'141'i '''''''\'''''''_ it , ' �������,, fi^, r17 1 i 1 ._ 1. i CONTENTS 1 . Water Flow Information 2. Hydraulic Calculations 3. Seismic Calculations 11' 410,4 40, 10, • ,4144 I — = ei4v1c1..:t3A.- I I ' 9 6 +.* , t . , ° . 4 WATER FLOW INFORMATION ill6 Western States Fire Protection Co. 17500 SW 65th Avenue,Lake Oswego,OR 97035 teeteicq.ilued egad to Phone:(503)657-5155•Fax:(503)657-5182 POWERED BY API GROIN HYDRANT FLOW TEST REPORT PROJECT: Port Plastics JOB NO: LC0917 LOCATION: 7500 SW Tech Center Dr. #100 DATE: 11/21/23 Portland, OR 97223 TIME: 8:00AM MAJOR CROSS STREETS: SW Tech Center Dr& SW 72nd Ave JURISDICTION: City of Tigard TEST MADE BY: Nathan Younce REPRESENTING: Western States Fire Protection WITNESSED BY: Dave with Tigard Public Works REPRESENTING: City of Tigard Public Works PURPOSE OF TEST: Water flow data for upgrade to existing fire sprinkler system. FLOW HYDRANTS A-1 A-2 A-3 B-2 C-1 C-2 SIZE NOZZLE-2.50/4.00 4.00 INCH PITOT READING 34 PSI DISCHARGE COEFFICIENT - - - FLOW 2200 GPM ELEVATION 170 FEET STATIC PRESSURE: 98 PSI STATIC HYDRANT ELEVATION: 178 FEET RESIDUAL PRESSURE: 82 PSI TOTAL FLOW: 2200 GPM FLOW @ 20 PSI: 5175 GPM - 14 Static/Residual , :.3.;:i . t= Hydrant , ,,, :::iiiivi: '-: ''El ''''.:..: J—. -..... s• .il"l. � � '�." Flow Hydrant .< , Y � sr% / r '' — ,€, t as IL REMARKS: Test conducted using a 4" Big Boy Hose Monster. 120 Fire Hydrant Flow Test 100 200,82 80 z 60 a M 6 40 20 517 5,20 of 0 1000 2000 3000 40O0 5000 6000 Flaw(GPM) ii MapTtle A �VICInIty map, � — , a 3eaverran B k. , :0." a,, Tjrg a r d f 01C00480011CC00D8ei49 7 01 D0006 . City of Tigard, Oregon '*; © Water Hydrants ,-- , ...„:„,,,a!„, (ter ' ; Flow Test Yes Tfka!al.4,1 + ow es o Water Valves 0 Gate Valve 0100004011)0 09 Butterfly Valve ao . —a__. .�6 DIP e_ aJ • Hydrant Valve -„ 77 • Other Valves � , 7477 _ 0 Closed Water Valves 0100039 ` co + Water Fittings 01C004 0042 � (� (�/n�//y� a���QQrJ �� w Water Main jr..-- C0040 t`.. ! Y - 0��QVW' "t w »da ,. v _xr^ In service 01C0043 1D0002 ;. J a New construction nT ., ?�.y _ a* " Abandoned 01CUOdd oicoo5201C005d 01D00{i7 1D0008 oic©o, . 0113000 3 12 DIP 12 DIP 12 DIP rO1cO053 12 DIP 01 Goo: RJ orcvos . y Static/Residual Hydrant !aSttC 7 - .43 t d Data,derived from multi Pia s s.The City of Tes to 1; makes n w only rapraaenlef�an,or ufl renlen as the u nten[,accuracy.timefinesa or completeness of any of the data yi ovldad herein.The ae�tYo f Tigard shall oi tblhty for ny err rs m aloha r e naccurac ea hn M1or maaa us eti rov des regardiuss of `7550 ow e 01C006(} 1C01062 01CU05r8, 6 DIP- 1"C0055 _01C t. 0` 01CO061_,--�1 Q t 1C0059 r _ .�m ,... Flow Hydrant re; Scale: 0.02 Miles :' ' T� City of Tigard °+r 13125 SW Hall Blvd : e `' Tigard, OR 97223 : '# Map Created: (503) 639-4171 1111712023 www.tigard-or.gov ' f�'��I'. I. h g�. a� A'b.WM p•.y,�.41 \N„, ',..i..4i;--.-c,:::;,-., '544,-'---- ' fib �� � �� Irl a sa w iy ` . • yt • 4111'4- y ,,► y y II''0 t tYkf$riI try ierr ; a ra f 8„f kk ,- r ' ye ry I - r HYDRAULIC CALCULATIONS Job Number:LC0917 Report Description:FM Storage v w * "� �� �... _ �..�1, �1'•.,�.�... .. ,x3 ". 'a_ �'i'. 1e Job Number Designer LC0917 Alexander Funk Job tame: Stete CertificatlorvLlcene NuMrer Port Plastics Address t AHJ 7500 SW Tech Center Dr.#100 Address 2 Job Sitelluiding Portland,OR 97223 Address 3 Drawing Name Sprinkler Plan Most Demsntlnq Spddder Data Omryarv:y Job Su1141 16.8 K-Factor 78.80 at 22.000 FM Storage Hose Allowance At Source Denby Area of Application 250.00 0.00 gpm/ft2 0 ft2(Actual 1368 ft2) Additional Hose Supplies Number Of SPhddors Calculated Number Of Nozzles Calculated Coverage Per Sprtnider Node Flow(ooml 15 0 130 ft2 AutoPeek Reuits:Pressure For Remote Area(s)Adjacent To Most Remote Area Left:75.499 Right:75.499 Total Hose Streams 250.00 System Flaw Demand Toal Water Regoired(InckMing H one Al owuae) 1251.38 1501.38 Maximum Pressure unbalance In Loops 0.000 Maximum Velocity Above Ground 18.80 between nodes 15 and 14 Maximum Velocity under Ground 12.96 between nodes 12 and 11 Volume capacity of Wet Pipes Volume capacity of Dry Pipes 4313.70 gal �''"� .., .... �" -#. Y,,� i w.'�� jz . �n �rt�,,, a '� 'x s`3, ...��.., ... '�,�,rw=�d � �,.,.,s ri=,. x..; Hose Flow Static Residual Flow Available Total Demand Required Safety Margin Node Name (gpm) (psi) (psi) (gpm) (psi) @ (gpm) (psi) (psi) 13 Water Supply 250.00 98.000 82.000 I 2200.00 90.109 I 1501.38 75.499 14.610 Contractor Number Contact Neme Contact Tale 241374 Alexander Funk Name of Contractor Phone Extension Western States Fire Protection 503-305-3018 Address I FAX 17500 SW 65th Ave Address 2 E-mail Lake Oswego,OR 97035 Alexander.Funk@wsfp.us Mdress 3 Web-Site wsfp.com �,©M.E.P.CAD AutoSPRINK 2023 v18.1.24.0 11/27/2023 2:08:01PM Page 1 • .+.,.„,. 1p, __> ., .._ , ..; Job Number:LC0917 Report Description:FM Storage Water Supply at Node 13 100 - I I I 0Static Pressure 98.000 90 1501.38 90.109 80 — 2200.00 @ 82. 1501.38 with hose streams 1251.38 @ 756.499 70 60 50 System demand curve a 40 30 20 10 0 1 1 1 1 ) 1 1 ) ) ) 0250 500 750 1000 1250 1500 1750 2000 2250 2500 Water flow,gpm Hydraulic Graph Water Supply at Node 13 Static:Pressure 98.000 Residual:Pressure Available Flow a 20 PSI: 82.000 @ 2200.00 4571.82 Available Pressure at System Demand 90.109 @ 1501.38 Raqui d Pressure at System Demand 75.499 @ 1251.38 Regrk d Pressure al System Demand(Includhg Hose Nmwanca St Saurce) 75.499 @ 1501.38 (� ©M.E.P.CAD ;j'j'.AutoSPRINK 2023 v18.1.24.0 11/27/2023 2:08:03PM Page 2 . el Job Number:LC0917 Report Description:FM Storage Actual Flow Minimum Flow K-Factor Pressure Device ((Wm) (gpm) (K) (psi) t4> Sprinkler 101 78.80 78.80 16.8 22.000 Sprinkler 102 78.80 78.80 16.8 22.000 Sprinkler 103 79.08 78.80 16.8 22.156 Sprinkler 104 80.05 78.80 16.8 22.706 Sprinkler 105 79.05 78.80 16.8 22.141 Sprinkler 106 79.94 78.80 16.8 22.642 Sprinkler 107 80.33 78.80 16.8 22.866 Sprinkler 108 80.54 78.80 16.8 22.981 Sprinkler 109 81.46 78.80 16.8 23.513 Sprinkler 110 83.94 78.80 16.8 24.964 Sprinkler 111 88.99 78.80 16.8 28.058 Sprinkler 112 88.99 78.80 16.8 28.058 Sprinkler 113 89.26 78.80 16.8 28.231 Sprinkler 114 89.02 78.80 16.8 28.078 b Most Demanding Sprinkler Data ,©M.E.P.CAD ill AutoSPRINK 2023 v18.1.24.0 11/27/2023 2:08:04PM Page 3 11 ^ x Job Number:LC0917 Report Description:FM Storage Node Elevation(Foot) Fittings Pressure(psi) Discharge(gpm) 13 -29'-3% S 75.499 1251.38 101 21-9 Spr(-22.000) 22.000 78.80 102 21-9 Spr(-22.000) 22.000 78.80 103 21'-9 Spr(-22.156) 22.156 79.08 104 21'-9 Spr(-22.706) 22.706 80.05 105 21'-9 Spr(-22.141) 22.141 79.05 106 21'-9 Spr(-22.642) 22.642 79.94 107 21.-5% Spr(-22.866) 22.866 80.33 108 21'-5% Spr(-22.981) 22.981 80.54 109 21-5% Spr(-23.513) 23.513 81.46 110 21'-9 Spr(-24.964) 24.964 83.94 111 21-5% Spr(-28.058) 28.058 88.99 112 21-5% Spr(-28.058) 28.058 88.99 113 21-5% Spr(-28.231) 28.231 89.26 114 21-5% Spr(-28.078) 28.078 89.02 115 21-2% Spr(-30.729) 30.729 93.13 1 2V-9 fT(14'-9%) 32.463 2 21'-9 32.500 3 19'-11 mecT(7'-5%) 36.301 4 19'-8 mecT(T-5%) 36.519 5 19'-5 mecT(7'-5%) 36.781 6 19'-2 mecT(7'-5%) 37.103 7 18'-11 mecT(7'-5'%) 37.473 8 18'-8 mecT(7'-5%) 37.890 9 18'-7'% P0(20'-2) 39.187 10 1'-6 BOR 56.280 11 0'-6 56.756 12 -23'-3% E(22'-%) 70.593 14 21'-9 fT(14'-10) 25.311 15 19'-11'% PO(16'-5%) 30.599 16 20'-2% PO(16'-5%) 30.888 17 22'-0 ff(14'-9%) 34.085 18 22'-0 34.100 19 20'-2 mecT(7'-5%) 36.138 20 19.-10% P0(16.-5%) 30.597 21 21'-5% fT(14'-9%) 28.520 22 19'-8'/z PO(16'-5%) 30.871 23 19'-5% PO(16'-S%) 31.346 24 19'-2% P0(16'-5%) 31.773 25 18'-11'% P0(16.-5%) 32.033 26 20'-8'% fT(14'-9%) 35.367 27 20'-8'/. 35.384 28 21'-5% fT(14'-9%) 33.661 29 21'-5% 33.686 30 2V-2% ff(14'-9%) 34.477 31 21'-2% 34.496 32 20.-5'% ff(14'-9%) 35.766 33 18'-8'/z P0(16'-5%) 37.002 34 20.-5'% 35.782 35 20'-11% fT(14'-9%) 34.995 36 20.-11'% 35.011 37 22'-3% fT(14'-9%) 33.971 38 22'-3% 33.986 39 20'-5 mecT(7'-5%) 35.996 40 22.-6'% fT(14'-9%) 33.857 41 22'-6'% 33.872 42 20'-8 mecT(7'-5%) 35.872 43 22'-9% fT(14'-9°%) 33.743 44 22.-9'% 33.757 45 20'-11 mecT(7'-5%) 35.758 46 20'-5'% P0(16-5%) 31.010 47 20'-8% P0(16'-5%) 31.009 g,©M.E.P.CAD J AutoSPRINK 2023 v18.1.24.0 11/27/2023 2:08:05PM Page 4 li . ,,...e,-,- Job Number:LC0917 Report Description:FM Storage Node Elevation(Foot) Fittings Pressure(psi) Discharge(gpm) 48 20'-11'% P0(16'-5%) 30.929 49 19'-2% PO(16'-5%) 36.185 50 18.-11'% PO(16'-5%) 36.572 51 19'-6 PO(16'-5'/,) 35.844 52 19'-9 P0(16-5%) 35.567 53 20-% P0(16'-5%) 35.345 54 20'-6% PO(16'-5%) 35.056 55 20'-3% PO(16'-5%) 35.193 56 21'-% P0(16'-5%) 34.813 57 20'-9'/: P0(16'-5%) 34.931 58 18'-8% PO(16'-5%) 32.180 rk,©M.E.P.CAD M AutoSPRINK 2023 v18.1.24.0 11/27/2023 2:08:05PM Page 5 [i ,- ' �R Job Number:LC0917 Report Description:FM Storage Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq.Length Summary Upstream Total Length OD Route 1 BL 2.6350 2.11 0.12 120 0.000023 8'-0 Pf 0.000 101 21'-9 78.80 16.8 22.000 Sprinkler Pe 102 21'-9 22.000 8'-0 Pv BL 2.6350 80.91 4.76 120 0.019463 8'-0 Pf 0.156 102 21'-9 78.80 16.8 22.000 Sprinkler Pe 103 21'-9 22.156 8'-0 Pv BL 2.6350 159.98 9.41 120 0.068705 8'-0 Pf 0.550 103 21'-9 79.08 16.8 22.156 Sprinkler Pe 104 21'-9 22.706 8'-0 Pv BL 2.6350 240.04 14.12 120 0.145534 52'-2% Pf 9.757 104 21'-9 80.05 16.8 22.706 Sprinkler, 14'-9% Pe 1 2V-9 32.463 fT(14'-9%) 67-'% Pv DY 2.6350 26.60 1.57 120 0.002486 0'-0 Pf 0.037 1 21'-9 32.463 fT(14'-9%) 14'-9% Pe -0.000 2 21'-9 32.500 14'-9% Pv BL 1.4420 26.60 5.23 120 0.046833 49'-4% Pf 3.010 2 21'-9 32.500 14.-10% Pe 0.792 3 19'-11 36.301 T(7'-5%),mecT(7'-5'/4) 64'-3'/4 Pv CM 3.2600 91.53 3.52 120 0.008673 12'-6 Pf 0.108 3 19'-11 64.93 36.301 Flow(q)from Route 2 Pe 0.110 4 19'-8 36.519 12'-6 Pv CM 3.2600 113.13 4.35 120 0.012835 12'-1 Pf 0.155 4 19'-8 21.60 36.519 Flow(q)from Route 6 Pe 0.106 5 19'-5 36.781 12'-1 Pv CM 3.2600 131.42 5.05 120 0.016935 12'-6 Pf 0.212 5 19'-5 18.29 36.781 Flow(q)from Route 8 Pe 0.110 6 19'-2 37.103 12'-6 Pv CM M 3.2600 148.43 5.71 120 0.021212 12'-4 Pf 0.262 6 19'-2 17.01 37.103 Flow(q)from Route 11 Pe 0.109 7 18'-11 37.473 12'-4 Pv CM 3.2600 165.46 6.36 120 0.025934 12'-0 Pf 0.311 7 18'-11 17.04 37.473 Flow(q)from Route 5 Pe 0.106 8 18'-8 37.890 12'-0 Pv CM 3.2600 182.66 7.02 120 0.031140 7'-1'/2 Pf 1.268 8 18'-8 17.20 37.890 Flow(q)from Route 10 33'-7% Pe 0.029 9 18'-7'% 39.187 2fE(6'-8%),PO(20'-2) 40'-8% Pv CM 6.3570 1251.38 12.65 120 0.042363 15'-4Y4 Pf 9.678 9 18'-7'% 1068.73 39.187 Flow(q)from Route 9 22'-7 Pe 7.415 10 1'-6 56.280 fE(12'-7),2f(-0.000),Tr(10'-0), 37'-11'% Pv BFP(-8.071),BOR FR 6.3570 1251.38 12.65 120 0.042363 1'-0 Pf 0.042 10 1'-6 56.280 Pe 0.434 11 0'-6 56.756 1'-0 Pv FR 6.2800 1251.38 12.96 140 0.033800 70'-101h Pf 3.514 11 0'-6 56.756 33'-1%4 Pe 10.323 12 -23'-3% 70.593 EE(11-'/2),E(22-%) 103.-11% Pv UG 8.3900 1251.38 7.26 140 0.008246 248'-11'% Pf 2.305 12 -23'-3% 70.593 30.-6% Pe 2.601 13 -29'-3% 75.499 E(30'-6+%) S 279'-5% Pv 250.00 Hose Allowance At Source 13 1501.38 v Route 2 BL 2.6350 76.69 4.51 120 0.017630 8'-0 Pf 0.141 101 21'-9 78.80 16.8 22.000 Sprinkler Pe 105 21'-9 22.141 8'-0 Pv BL 2.6350 155.74 9.16 120 0.065375 7'-8 Pf 0.501 105 21'-9 79.05 16.8 22.141 Sprinkler Pe 106 21'-9 22.642 7'-8 Pv BL 2.6350 235.68 13.87 120 0.140690 4'-1% Pf 2.669 106 21'-9 79.94 16.8 22.642 Sprinkler, 14'-10 Pe 0.000 14 21'-9 25.311 fT(14-10) 18'-11% Pv RN 2.6350 319.62 18.80 120 0.247191 1'-9% Pf 4.514 14 21'-9 83.94 25.311 Flow(q)from Route 4 16'-5% Pe 0.774 15 19'-11% 30.599 P0(16.-5%) 18'-3 Pv ik,©M.E.P.CAD di AutoSPRINK 2023 v18.1.24.0 11/27/2023 2:08:07PM Page 6 � e . d � , � �� , .� 4 Job Number:LC0917 Report Description:FM Storage Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq.Length Summary Upstream Total Length CM 4.2600 378.31 8.52 120 0.032543 12'-2 Pf 0.396 15 19'-11'% 58.69 30.599 Flow(q)from Route 3 Pe -0.107 16 20'-2'% 30.888 12'-2 Pv RN 2.6350 97.76 5.75 120 0.027624 97'-10 Pf 3.977 16 20'-2'/: 30.888 P0(16'-53/4) 46'-1'/: Pe -0.779 17 22'-0 34.085 fT(14'-10),fT(14'-93/4) 143.-11'% Pv DY 2.6350 16.47 0.97 120 0.001025 0'-0 Pf 0.015 17 22'-0 34.085 fT(14'-9%) 14'-9% Pe 18 22'-0 34.100 14'-9% Pv BL 1.4420 16.47 3.24 120 0.019302 49'-5 Pf 1.241 18 22'-0 34.100 14.-10'% Pe 0.797 19 20.-2 36.138 T(7'-5%),mecT(7'-5%) 64'-3% Pv CM 3.2600 64.93 2.50 120 0.004595 12'-2 Pf 0.056 19 20'-2 48.46 36.138 Flow(q)from Route 12 Pe 0.107 3 19'-11 36.301 12'-2 Pv es Route 3 BL 2.6350 80.33 4.73 120 0.019210 6'-0 Pf 0.115 107 21'-5% 80.33 16.8 22.866 Sprinkler Pe 108 21'-53/4 22.981 6'-0 Pv BL 2.6350 160.87 9.46 120 0.069412 7'-8 Pf 0.532 108 21'-5% 80.54 16.8 22.981 Sprinkler Pe 109 21'-5% 23.513 7'-8 Pv BL 2.6350 242.33 14.26 120 0.148122 14'-10'% Pf 6.391 109 21'-5% 81.46 16.8 23.513 Sprinkler, 28'-3% Pe 0.693 20 19.-10'% 30.597 2fE(5'-10' ),P0(16'-5%) 43'-1% Pv CM 4.2600 58.69 1.32 120 0.001036 19'-7 Pf 0.037 20 19'-10'% 30.597 15'-9 Pe -0.035 15 19'-111% 30.599 Tr(6'-9'/a),fE(8'-111/n) 35'-4 Pv ® Route 4 BL 2.6350 83.94 4.94 120 0.020835 1'-10Y. Pf 0.348 110 21'-9 83.94 16.8 24.964 Sprinkler, 14'-10 Pe 0.000 14 21'-9 25.311 fT(14'-10) 16'-8% Pv w Route 5 BL 2.6350 3.38 0.20 120 0.000055 8'-0 Pf 0.000 111 21.-5% 88.99 16.8 28.058 Sprinkler Pe 112 21'-5% 28.058 8'-0 Pv BL 2.6350 92.37 5.43 120 0.024869 3'-9% Pf 0.462 112 21'-5% 88.99 16.8 28.058 Sprinkler, 14'-9% Pe 21 21'-5% 28.520 fT(14'-93/�) 18'-7 Pv RN 2.6350 181.39 10.67 120 0.086671 1'-9% Pf 1.582 21 21'-5% 89.02 28.520 Flow(q)from Route 7 16'-5% Pe 0.769 22 19'-8'% 30.871 PO(16'-5%) 18'-3 Pv CM 4.2600 365.03 8.22 120 0.030461 12'-1 Pf 0.368 22 19.-8'% 183.64 30.871 Flow(q)from Route 24 Pe 0.107 23 19'-5'% 31.346 12'-1 Pv CM 4.2600 330.68 7.44 120 0.025370 12'-6 Pf 0.317 23 19'-5'% 31.346 Pe 0.110 24 19'-2'% 31.773 12'-6 Pv CM 4.2600 222.68 5.01 120 0.012208 12'-4 Pf 0.151 24 19'-2'% 31.773 Pe 0.109 25 18'-11'/z 32.033 12'-4 Pv RN 2.6350 109.58 6.45 120 0.034114 73'-8% Pf 4.089 25 18'-11% 32.033 P0(16.-5%) 46.-1'% Pe -0.754 26 20'-8'% 35.367 fT(14'-10),fT(14'-9%) 119'-10'% Pv DY 2.6350 17.04 1.00 120 0.001090 0'-0 Pf 0.016 26 20'-8'% 35.367 fT(14'-9%) 14'-9% Pe 27 20.-8'% 35.384 14.-9%Pv BL 1.4420 17.04 3.35 120 0.020534 49'-4% Pf 1.319 27 20.-8% 35.384 14.-10'% Pe 0.771 7 18'-11 37.473 T(7.-5%),mecT(7'-5%) 64'-2'% Pv o Route 6 BL 2.6350 85.61 5.04 120 0.021609 8.-0 Pf 0.173 111 21.-5% 88.99 16.8 28.058 Sprinkler Pe 113 21'-5% 28.231 8'-0 Pv BL 2.6350 174.87 10.29 120 0.081002 52'-23h Pf 5.431 113 21'-5% 89.26 16.8 28.231 Sprinkler, 14.-9% Pe 28 21.-5% 33.661 f(14,-9%) 67'-'/z Pv tk,©M.E.P.CAD itAutoSPRINK 2023 v18.1.24.0 11/27/2023 2:08:07PM Page 7 n. -. Z. 4 ., Job Number:LC0917 Report Description:FM Storage Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq.Length Summary Upstream Total Length DY 2.6350 21.60 1.27 120 0.001691 0'-0 Pf 0.025 28 21'-5% 33.661 fT(14'-9a ) 14.-9% Pe 0.000 29 21'-5% 33.686 14'-9% Pv BL 1.4420 21.60 4.24 120 0.031852 49'-4% Pf 2.046 29 21'-5% 33.686 14.-10'% Pe 0.786 4 19'-8 36.519 T(7.-5%),mecT(7'-5%) 64'-3 Pv = Route 7 BL 2.6350 89.02 5.24 120 0.023228 4'-2% Pf 0.442 114 21.-5% 89.02 16.8 28.078 Sprinkler, 14.-9% Pe 21 21.-5% 28.520 fT(14'-9%) 19'-'/a Pv ® Route 8 BL 2.6350 127.48 7.50 120 0.045138 68'-2% Pf 3.748 115 21'-2% 34.36 16.8 30.729 Sprinkler„Flow(q)from Route 14.-9% Pe 30 21'-2% 34.477 27 83'%a Pv fT(14'-9%) D Y 2.6350 18.29 1.08 120 0.001243 0.-0 Pf 0.018 30 21.-2% 34.477 fT(14'-9%) 14.-9% Pe -0.000 31 21'-2% 34.496 14'-93h Pv BL 1.4420 18.29 3.59 120 0.023414 49.-4% Pf 1.504 31 21'-2% 34.496 14'-10'% Pe 0.781 5 19'-5 36.781 T(7'-5/,),mecT(7'-5%) 64'-2% Pv ® Route 9 RN 2.6350 95.91 5.64 120 0.026660 1'-8% Pf 0.485 32 20.-5% 113.10 35.766 Flow(q)from Route 25 16'-5'/, Pe 0.750 33 18.-8'% 37.002 P0(16.-5%) 18'-2'/a Pv CM 6.3570 1068.73 10.80 120 0.031639 55.-1 Pf 2.141 33 18.-8'% 972.82 37.002 Flow(q)from Route 18 12.-7 Pe 0.045 9 18.-7'% 39.187 fE(12'-7) 67.-8 Pv ® Route 10 DY 2.6350 17.20 1.01 120 0.001109 0'-0 Pf 0.016 32 20'-5% 113.10 35.766 fT(14'-9%),Flow(q)from Route 14.-9% Pe 0.000 34 20'-5% 35.782 25 14'-93/, Pv BL 1.4420 17.20 3.38 120 0.020895 49'-4 Pf 1.342 34 20.-5/. 35.782 14'-10% Pe 0.766 8 18'-8 37.890 T(7'-5%),mecT(7'-5%) 64'-2% Pv OD Route 11 DY 2.6350 17.01 1.00 120 0.001087 0.-0 Pf 0.016 35 20'-11'% 108.00 34.995 fT(14'-9%),Flow(q)from Route 14.-9% Pe 36 20'-11'% 35.011 26 14.-9% Pv BL 1.4420 17.01 3.34 120 0.020483 49'-4% Pf 1.316 36 20'-11'% 35.011 14.-10'% Pe 0.776 6 19'-2 37.103 T(7'-5%),mecT(7'-5%) 64'-2% Pv c Route 12 DY 2.6350 16.24 0.96 120 0.000998 0'-0 Pf 0.015 37 22'-3% 94.65 33.971 fT(14'-9%),Flow(q)from Route 14'-93/4 Pe 0.000 38 22'-3% 33.986 15 14'-9% Pv BL 1.4420 16.24 3.19 120 0.018792 49'-5 Pf 1.208 38 22'-3'% 33.986 14'-10'% Pe 0.802 39 20'-5 35.996 T(7'-5%),mecT(7'-5%) 64'-3'%Pv CM 3.2600 48.46 1.86 120 0.002674 12'-4 Pf 0.033 39 20'-5 32.22 35.996 Flow(q)from Route 13 Pe 0.109 19 20'-2 36.138 12'-4 Pv e= Route 13 DY 2.6350 16.13 0.95 120 0.000985 0'-0 Pf 0.015 40 22'-6% 93.16 33.857 fl(14'-9%),Flow(q)from Route 14'-9a/. Pe 0.000 41 22'-6% 33.872 16 14.-9% Pv BL 1.4420 16.13 3.17 120 0.018551 49'-5/, Pf 1.193 41 22'-6'% 33.872 14'-10% Pe 0.807 42 20'-8 35.872 T(7'-5%),mecT(7'-5%) 64'-3'%Pv CM 3.2600 32.22 1.24 120 0.001257 12'-4 Pf 0.016 42 20.-8 16.09 35.872 Flow(q)from Route 14 Pe 0.109 39 20'-5 35.996 12'-4 Pv o Route 14 (A,©M.E.P.CAD NgAutoSPRINK 2023 v18.1.24.0 11/27/2023 2:08:07PM Page 8 € Job Number:LC0917 Report Description:FM Storage Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq.Length Summary Upstream Total Length DY 2.6350 16.09 0.95 120 0.000981 0'-0 Pf 0.015 43 22'-9'/ 92.74 33.743 fT(14'-9%),Flow(q)from Route 14'-9% Pe 44 22'-9'% 33.757 17 14'-9%Pv BL 1.4420 16.09 3.16 120 0.018481 49'-5% Pf 1.189 44 22'-9'% 33.757 14'-10% Pe 0.812 45 20'-11 35.758 T(7'-5%),mecT(7'-5%) 64'-3%Pv CM 3.2600 16.09 0.62 120 0.000348 12'-5% Pf 0.004 45 20'-11 35.758 Pe 0.110 42 20'-8 35.872 12'-5% Pv es Route 15 CM 4.2600 280.55 6.32 120 0.018717 12'-4 Pf 0.231 16 20'-2% 97.76 30.888 Flow(q)from Route 2 Pe -0.109 46 20'-5% 31.010 12'-4 Pv RN 2.6350 94.65 5.57 120 0.026017 97'-10'% Pf 3.746 46 20'-5'% 31.010 P0(16-5%) 46'-1'% Pe -0.784 37 22'-3% 33.971 fT(14'-10),fT(14'-9%) 143'-11'% Pv es Route 16 CM 4.2600 185.90 4.18 120 0.008742 12'-4 Pf 0.108 46 20'-5% 94.65 31.010 Flow(q)from Route 15 Pe -0.109 47 20'-8% 31.009 12'-4 Pv RN 2.6350 93.16 5.48 120 0.025266 97'-10% Pf 3.638 47 20'-8% 31.009 PO(16'-5%) 46'-1'% Pe -0.789 40 22'-6'% 33.857 fT(14'-10),fT(14'-9%) 143'-11% Pv w Route 17 CM 4.2600 92.74 2.09 120 0.002415 12'-5% Pf 0.030 47 20'-8% 93.16 31.009 Flow(q)from Route 16 Pe -0.110 48 20'-11% 30.929 12'-5'% Pv RN 2.6350 92.74 5.46 120 0.025055 97'-10'/ Pf 3.608 48 20'-11'% 30.929 P0(16'-5%) 46'-1'/z Pe -0.794 43 22'-9% 33.743 fT(14'-10),fT(14'-9' ) 143'-11%Pv ® Route 18 CM 6.3570 880.28 8.90 120 0.022098 12'-4 Pf 0.273 49 19'-2% 789.29+90.99 36.185 Flow(q)from Route 19 and 32 Pe 0.114 50 18'-11% 36.572 12'-4 Pv CM 6.3570 972.82 9.83 120 0.026587 12'-0 Pf 0.319 50 18'-11% 92.54 36.572 Flow(q)from Route 34 Pe 0.111 33 18'-8'% 37.002 12'-0 Pv GO Route 19 CM 6.3570 789.29 7.98 120 0.018059 12'-6 Pf 0.226 51 19'-6 680.10+109.20 35.844 Flow(q)from Route 20 and 33 Pe 0.115 49 19'-2% 36.185 12'-6 Pv = Route 20 RN 2.6350 153.28 9.02 120 0.063473 1'-8% Pf 1.155 28 21'-5% 21.60 33.661 Flow(q)from Route 6 16'-5% Pe 0.750 52 19'-9 35.567 PO(16'-5%) 18'-2'% Pv CM 6.3570 680.10 6.87 120 0.013711 12'-1 Pf 0.166 52 19'-9 526.82 35.567 Flow(q)from Route 21 Pe 0.112 51 19'-6 35.844 12'-1 Pv ea? Route 21 RN 2.6350 213.44 12.56 120 0.117110 1'-83/4 Pf 2.132 1 21'-9 26.60 32.463 Flow(q)from Route 1 16'-5% Pe 0.750 53 20-% 35.345 P0(16'-5%) 18'-2% Pv CM 6.3570 526.82 5.33 120 0.008548 12'-6 Pf 0.107 53 20'-'% 313.38 35.345 Flow(q)from Route 22 Pe 0.115 52 19'-9 35.567 12'-6 Pv o Route 22 CM 6.3570 232.09 2.35 120 0.001876 12'-4 Pf 0.023 54 20'-6'% 153.68+78.41 35.056 Flow(q)from Route 23 and 30 Pe 0.114 55 20'-3% 35.193 12'-4 Pv CM 6.3570 313.38 3.17 120 0.003270 12'-2 Pf 0.040 55 20'-3'% 81.29 35.193 Flow(q)from Route 31 Pe 0.112 53 20'-% 35.345 12'-2 Pv es Route 23 CM 6.3570 76.65 0.77 120 0.000242 12'-5% Pf 0.003 56 21'-% 76.65 34.813 Flow(q)from Route 28 Pe 0.115 57 20'-9'% 34.931 12'-5% Pv k©M.E.P.CAD illAutoSPRINK 2023 v18.1.24.0 11/27/2023 2:08:07PM Page 9 • Job Number:LC0917 �� `� � � Report Description:FM Storage Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq.Length Summary Upstream Total Length CM 6.3570 153.68 1.55 120 0.000875 12'-4 Pf 0.011 57 20'-9% 77.04 34.931 Flow(q)from Route 29 Pe 0.114 54 20'-6% 35.056 12'-4 Pv so Route 24 CM 4.2600 183.64 4.13 120 0.008546 16'-71% Pf 0.198 20 19'-10% 58.69 30.597 Flow(q)from Route 3 6'-7 Pe 0.076 22 19'-8% 30.871 fE(6'-7) 23'-2'% Pv ® Route 25 CM 4.2600 113.10 2.55 120 0.003486 12'-0 Pf 0.042 25 18'-11'% 109.58 32.033 Flow(q)from Route 5 Pe 0.106 58 18'-8'% 32.180 12'-0 Pv RN 2.6350 113.10 6.65 120 0.036172 73'-8'/. Pf 4.335 58 18'-8'% 32.180 P0(16'-5%) 46'-1% Pe -0.749 32 20'-5'% 35.766 fT(14'-10),fT(14'-9'/.) 119'-10'% Pv o Route 26 RN 2.6350 108.00 6.35 120 0.033210 73'-9 Pf 3.981 24 19'-2'% 31.773 P0(16.-5%) 46'-1'% Pe -0.759 35 20'-11'% 34.995 fT(14'-10),fT(14'-9%) 119.-10'% Pv 4111 Route 27 RN 2.6350 34.36 2.02 120 0.003991 5'-6'% Pf 0.147 23 19.-5'% 31.346 P0(16'-5%) 31'-3'% Pe -0.764 115 21'-2% 30.729 fT(14'-10) 36'-10 Pv CI Route 28 RN 2.6350 76.65 4.51 120 0.017611 1'-8% Pf 0.321 43 22'-9% 92.74 33.743 Flow(q)from Route 17 16'-5% Pe 0.750 56 21-% 34.813 PO(16'-5%) 18'-2'%Pv 411 Route 29 RN 2.6350 77.04 4.53 120 0.017776 1'-8% Pf 0.324 40 22'-6% 93.16 33.857 Flow(q)from Route 16 16.-5% Pe 0.750 57 20'-9'% 34.931 • PO(16'-5%) 18'-2'% Pv Q Route 30 RN 2.6350 78.41 4.61 120 0.018367 1'-8% Pf 0.334 37 22'-3% 94.65 33.971 Flow(q)from Route 15 16'-5% Pe 0.750 54 20'-6'% 35.056 PO(16'-5%) 18'-2% Pv 411, Route 31 RN 2.6350 81.29 4.78 120 0.019634 1-8% Pf 0.357 17 22'-0 16.47 34.085 Flow(q)from Route 2 16'-5% Pe 0.750 55 20'-3% 35.193 P0(16'-5%) 18'-2'% Pv v Route 32 RN 2.6350 90.99 5.35 120 0.024185 1'-8% Pf 0.440 35 20'-11'% 108.00 34.995 Flow(q)from Route 26 16'-5% Pe 0.750 49 19'-2% 36.185 P0(16'-5%) 18'-2'% Pv ® Route 33 RN 2.6350 109.20 6.42 120 0.033895 1-8% Pf 0.617 30 21'-2% 18.29 34.477 Flow(q)from Route 8 16'-5% Pe 0.750 51 19'-6 35.844 P0(16'-5%) 18'-2'%Pv Q. Route 34 RN 2.6350 92.54 5.44 120 0.024956 1'-8% Pf 0.454 26 20'-8'% 17.04 35.367 Flow(q)from Route 5 16'-5% Pe 0.750 50 18'-11'% 36.572 PO(16'-5%) 18'-2'% Pv F w.^Y....-. .s c _ .9.,... ffi b�` !.A'E au v'.v k ...aw'�. l: • 9' ,' ,��S>t✓n Actual Inside Diameter 4.87 Value Of C 100 130 140 150 ( Schedule 40 Steel Pipe Inside Diameter ) =Factor Multiplying Factor 0.713 1.16 1.33 1.51 k,©M.E.P.CAD le AutoSPRINK 2023 v18.1.24.0 11/27/2023 2:08:07PM Page 10 �x. F �,41�' Job Number:LC0917 Report Description:FM Storage Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq.Length Summary Upstream Total Lengthy AO Arm-Over Diameter Inch ALV Alarm Valve BL Branch Line Elevation Foot AngV Angle Valve CM Cross Main Flow gpm b Bushing DN Drain Discha e m Be/ Ball Valve DR Drop r9 gp BFP Backflow Preventer DY Dynamic Velocity fps BV Butterfly Valve FM Feed Main Pressure psi C Cross Flow Turn 90° FR Feed Riser Length Foot cplg Coupling MS Miscellaneous Friction Loss psi/Foot Cr Cross Run OR Outrigger HWC Hazen-Williams Constant CV Check Valve RN Riser Nipple DelV Deluge Valve Pt Total pressure at a point in a pipe SN Swing Nipple DPV Dry Pipe Valve SP Sprig Pn Normal pressure at a point in a pipe E 90°Elbow ST Stand Pipe Pf Pressure loss due to friction between points EE 45°Elbow UG Underground Pe Pressure due to elevation difference between indicated Eel 11'Y.°Elbow points Ee2 22W Elbow Pv Velocity pressure at a point in a pipe f Flow Device fd Flex Drop FDC Fire Department Connection fE 90°FireLock(TM)Elbow fEE 45°FireLock(TM)Elbow flg Flange FN Floating Node fT FireLock(TM)Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Tum 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap �,©M.E.P.CAD AutoSPRINK 2023 v18.1.24.0 11/27/2023 2:08:07PM Page 11 „,,,,,,,,i,,,,,...'S:;..',....i.:14‘7, -"k'."'.41,144.., ''',..' . — \ aM Y. b4� ty 4 4 '# C '`� lie + . ' . I , - ii - / V. :4 _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _.. a . ”. 4. ,yrif �� ER VI/L f3aY ` �- tll ; '' a afi y 1 rv� '+0.. i a 4 9.,i i`-Ci {r t .—> � t t -. ., , SEISMIC CALCULATIONS TOLBraceTM Seismic Bracing Calculations V8.8.124 Contractor: Western States Fire Protectia Project Address: Port Plastics Address: 17500 SW 65th Ave. Lake Oswego,OR 97035 7500 SW Tech Center Dr.#100 MwsmpBusitiessWrrfdwide Phone: 503-305-3018 Portland,OR 97223 Licence: 241374 Job#LC0917 Calculations based on 2019 NFPA Pamphlet#13 Brace Information TOLCOTM Brace Components TOLCOTM Component Listed Load Adjusted Load Maximum Brace Length 10'6"(3.2 m) Diameter of Brace 1 Fig. 1001 Clamp 2000 lbs(907 kg) 1414 lbs(641 kg) Fig.980-1/2"Universal Swive 2100 lbs(953 kg) 1485 lbs(674 kg) Type of Brace Sch.40 See Fastener Information 45°Min. *Calculation Based on CONCENTRIC Loading Angle of Brace *Please Note:These calculations are for TOLCOTM components only.Use of any other components voids these calculations and the listing of the assembly. Least Rad.of Gyration 0.42"(11 mm) Seismic Brace Assembly Detail L/R Value 300 foLCO FI0.9t6 U«Nl RSK Max Horizontal Load 582 lbs(264 kg) ATT DRAM Fastener Information ORACC PIP! Orientation to Connecting Surface NFPA Type E Fastener Type 1/2in.x 3 1/2in.Thru Bolt Diameter 1/2in Length 3 1/2in. Maximum Load 350 lbs(159 kg) acorn amA,t:BR,i',Go Brace Identification on Plans 6"Lateral Bracing-A Prying Factor N/A Brace Type Lateral[X] Longitudinal[ ] 4-Way[ ] Sprinkler System Load Calculation (Fpw=CpWp) Cp= _0.456 Diameter Type Length Total Length Weight Per Unit Length Total Weight 6"(150 mm) Sch.10 12.5 ft(3.8 m) 12.5 ft(3.8 m) 23.03 lb/ft(34.27 kg/m) 288 lbs(131 kg) 2.5"(65 mm) Sch. 10 36 ft(11 m) 36 ft(11 m) 5.89 lb/ft(8.77 kg/m) 212 lbs(96 kg) 1.25"(32 mm) Sch.10 25 ft(7.6 m) 25 ft(7.6 m) 2.52 lb/ft(3.75 kg/m) 63 lbs(29 kg) Subtotal Weight 563 lbs(255 kg) Wp(incl. 15%) 647 lbs(294 kg) Main Size Type/Sch. Spacing(ft) I Total(Fpw) 295 lbs(134 kg) 6" Sch.10 12.5 Maximum Fpw per 18.5.5.2(if applicable) 4039 lb(1832 kg) 1TOLBrace"Version 81 Use of TOLBracen"is subject to terms and conditions per the end user license agreement TOLBraceTM Seismic Calculations Port Plastics Job#LC0917 7500 SW Tech Center Dr.#100 E_TeN Brace Identification 6" Lateral Bracing-A aewoawawriao Brace Type(Per NFPA#13) NFPA Type E Braced Pipe(ft) 6"Sch.10 Steel Pipe Spacing of Brace 12'6" (3.81 m) Orientation of Brace Lateral Bracing Material 1"Sch.40 Maximum Brace Length 10'6" (3.2 m) Slenderness Ratio used for Load Calculation 300 True Angle of Brace for Calculation 45° Type of Fastener 1/2in.x 3 1/2in.Thru Bolt Length of Fastener 3 1/2in. Summary of Pipe within Zone of Influence 6"Sch.10 Steel Pipe(152.4 mm) 12.5 ft(3.8 m) 2.5"Sch.10 Steel Pipe(63.5 mm) 36 ft(11 m) 1.25"Sch.10 Steel Pipe(31.75 mm) 25 ft(7.6 m) G-Factor Used 0.456 Allowance for Heads and Fittings 15% Conclusions Total Adjusted Load of Pipe in Zone of Influence 295 lbs(134 kg) Material Capacity 582 lbs(264 kg) Fastener Capacity 350 lbs(159 kg) Fig. 1001 Clamp 1414 lbs(641 kg) Fig.980- 1/2" Universal Swivel 1485 lbs(674 kg) Structural Member Wood Beam Calculations prepared by Alexander Funk *The description of the Structural Member is for informational purposes only. TOLBrace'°software calculates the brace assembly only,not the structure it is attached to. Calculated with TOLBrace'"8 Visit us at www.tolco.com TOLBraceTM Seismic Bracing Calculations V8.8.124 Contractor: Western States Fire Protectic Project Address: Port Plastics Address: 17500 SW 65th Ave. Lake Oswego,OR 97035 IF-T 7500 SW Tech Center Dr.#100 Powering Sa inessittridwrde Phone: 503-305-3018 Portland,OR 97223 Licence: 241374 Job#LC0917 Calculations based on 2019 NFPA Pamphlet#13 Brace Information TOLCOTM Brace Components TOLCOTM Component Listed Load Adjusted Load Maximum Brace Length 10.6"(3.2 m) Diameter of Brace 1 Fig. 1001 Clamp 2000 lbs(907 kg) 1414 lbs(641 kg) Fig.980-1/2"Universal Swive 2100 lbs(953 kg) 1485 lbs(674 kg) Type of Brace Sch.40 See Fastener Information 45°Min. "Calculation Based on CONCENTRIC Loading Angle of Brace *Please Note:These calculations are for TOLCOT"components only.Use of any other components voids these calculations and the listing of the assembly. Least Rad.of Gyration 0.42 R(11 mm) Seismic Brace Assembly Detail UR Value 300 !OLEO re 9"0 Max Horizontal Load 582 lbs(264 kg) ,NK�KYBRARg MI W BRACE Fastener Information BRAG!Pi! Orientation to Connecting Surface NFPA Type E Fastener Type 1/2in.x 3 1/2in.Thru Bolt Diameter 1/2in. Length 3 1/2in. Maximum Load 350 lbs(159 kg) TOMOPIIO 0 _... ,.� SNAYBIICINO Brace Identification on Plans 6"Lateral Bracing-B Prying Factor N/A Brace Type Lateral[X] Longitudinal[ ] 4-Way[ ] Sprinkler System Load Calculation (Fpw=CpWp) Cp= 0.456_ Diameter Type Length Total Length Weight Per Unit Length Total Weight 6"(150 mm) Sch.10 19 ft(5.8 m) 19 ft(5.8 m) 23.03 lb/ft(34.27 kg/m) 438 lbs(199 kg) 2.5"(65 mm) Sch. 10 16 ft(4.9 m) 16 ft(4.9 m) 5.89 lb/ft(8.77 kg/m) 94 lbs(43 kg) 1.25"(32 mm) Sch.10 50 ft(15.2 m) 50 ft(15.2 m) 2.52 lb/ft(3.75 kg/m) 126 lbs(57 kg) Subtotal Weight 658 lbs(298 kg) Wp(incl. 15%) 757 lbs(343 kg) Main Size Type/Sch. Spacing(ft) I Total(Fpw) 345 lbs(157 kg) 6" Sch.10 19 Maximum Fpw per 18.5.5.2(if applicable) 4039 lb(1832 kg) {TOLBrace'""Version 81 Use of TOLBracerM is subject to terms and conditions per the end user license agreement TOLBraceml Seismic Calculations Port Plastics Job#LC0917 7500 SW Tech Center Dr.#100 IF:'[•N Brace Identification 6" Lateral Bracing-B Aowpn�ya �rsi�a Brace Type(Per NFPA#13) NFPA Type E Braced Pipe(ft) 6"Sch.10 Steel Pipe Spacing of Brace 19'0"(5.79 m) Orientation of Brace Lateral Bracing Material 1"Sch.40 Maximum Brace Length 10'6"(3.2 m) Slenderness Ratio used for Load Calculation 300 True Angle of Brace for Calculation 45° Type of Fastener 1/2in.x 3 1/2in.Thru Bolt Length of Fastener 3 1/2in. Summary of Pipe within Zone of Influence 6"Sch.10 Steel Pipe(152.4 mm) 19 ft(5.8 m) 2.5"Sch.10 Steel Pipe(63.5 mm) 16 ft(4.9 m) 1.25"Sch.10 Steel Pipe(31.75 mm) 50 ft(15.2 m) G-Factor Used 0.456 Allowance for Heads and Fittings 15% Conclusions Total Adjusted Load of Pipe in Zone of Influence 345 lbs(156 kg) Material Capacity 582 lbs(264 kg) Fastener Capacity 350 lbs(159 kg) Fig. 1001 Clamp 1414 lbs(641 kg) Fig.980- 1/2" Universal Swivel 1485 lbs(674 kg) Structural Member Wood Beam Calculations prepared by Alexander Funk *The description of the Structural Member is for informational purposes only. TOLBrac&"software calculates the brace assembly only,not the structure it is attached to. Calculated with TOLBraceTM 8 Visit us at www.tolco.com TOLBraceTM Seismic Bracing Calculations V8.8.124 I Contractor: Western States Fire Protectic Project Address: Port Plastics Address: 17500 SW 65th Ave. Lake Oswego,OR 97035 F.T*N 7500 SW Tech Center Dr.#100 Pow*);BusinessiNandwidt Phone: 503-305-3018 Portland,OR 97223 Licence: 241374 Job#LC0917 Calculations based on 2019 NFPA Pamphlet#13 Brace Information TOLCOTM Brace Components Maximum Brace Length 10'6"(3.2 m) TOLCOTM Component Listed Load Adjusted Load Diameter of Brace 1" Fig.4L Clamp 2000 lbs(907 kg) 1414 lbs(641 kg) Fig.980-1/2"Universal Swive 2100 lbs(953 kg) 1485 lbs(674 kg) Type of Brace Sch.40 See Fastener Information Angle of Brace 45 *Calculation Based on CONCENTRIC Loading Min. •Please Note:These calculations are for TOLCOT"components only.Use of any other components voids these calculations and the listing of the assembly. Least Rad.of Gyration 0.42' (11 mm) Seismic Brace Assembly Detail L/R Value 300 TOLCO FIG.980 Max Horizontal Load 582 lbs(264 kg) "O Fastener Information BRACE PIPE Orientation to Connecting Surface NFPA Type H Fastener Type 1/2in.x 3 1/2in.Thru Bolt n TOLCO FIG.4L Diameter 1/2in. Length 3 1/2in. Maximum Load 330 lbs(150 kg) lin Brace Identification on Plans 6"Longitudinal Bracing Prying Factor N/A Brace Type Lateral[ ] Longitudinal[X] 4-Way[ ] Sprinkler System Load Calculation (Fpw=CpWp) Cp= _ 0.456 _ Diameter Type Length Total Length Weight Per Unit Length Total Weight 6"(150 mm) Sch. 10 25 ft(7.6 m) 25 ft(7.6 m) 23.03 lb/ft(34.27 kg/m) 576 lbs(261 kg) Subtotal Weight 576 lbs(261 kg) Wp(incl.15%) 662 lbs(300 kg) Main Size Type/Sch. Spacing(ft) I Total(Fpw) 302 lbs(137 kg) 6" Sch.10 25 Maximum Fpw per 18.5.5.2(if applicable) N/A fTOLBraceTM Version 8) Use of TOLBracen,is subject to terms and conditions per the end user license agreement TOLBraceml Seismic Calculations Port Plastics Job#LC0917 7500 SW Tech Center Dr.#100 6:T•N Pawing 9 inessWorldwide Brace Identification 6" Longitudinal Bracing Brace Type(Per NFPA#13) NFPA Type H Braced Pipe(ft) 6"Sch.10 Steel Pipe Spacing of Brace 25'0" (7.62 m) Orientation of Brace Longitudinal Bracing Material 1"Sch.40 Maximum Brace Length 10'6" (3.2 m) Slenderness Ratio used for Load Calculation 300 True Angle of Brace for Calculation 45° Type of Fastener 1/2in.x 3 1/2in.Thru Bolt Length of Fastener 3 1/2in. Summary of Pipe within Zone of Influence 6"Sch.10 Steel Pipe(152.4 mm) 125 ft(7.6 m) G-Factor Used 0.456 Allowance for Heads and Fittings 15% Conclusions Total Adjusted Load of Pipe in Zone of Influence 302 lbs(137 kg) Material Capacity 582 lbs(264 kg) Fastener Capacity 330 lbs(150 kg) Fig.4L Clamp 1414 lbs(641 kg) Fig.980- 1/2" Universal Swivel 1485 lbs(674 kg) Structural Member Wood Beam Calculations prepared by Alexander Funk *The description of the Structural Member is for informational purposes only. TOLBrace'software calculates the brace assembly only,not the structure it is attached to. Calculated with TOLBrace''8 Visit us at www.tolco.com TOLBraceTM Seismic Bracing Calculations V8.8.124 Contractor: Western States Fire Protectic Project Address: Port Plastics Address: 17500 SW 65th Ave. Lake Oswego,OR 97035 IFA aT 7500 SW Tech Center Dr.#100 Ptn,*fiusinassVtdrridwfde Phone: 503-305-3018 Portland,OR 97223 Licence: 241374 Job#LC0917 Calculations based on 2019 NFPA Pamphlet#13 Brace Information TOLCOTM Brace Components TOLCOTM Component Listed Load Adjusted Load Maximum Brace Length 10'6"(3.2 m) Diameter of Brace 1" Fig. 1001 Clamp 2000 lbs(907 kg) 1414 lbs(641 kg) Fig.980-1/2"Universal Swive 2100 lbs(953 kg) 1485 lbs(674 kg) Type of Brace Sch.40 See Fastener Information Min. "Calculation Based on CONCENTRIC Loading 45°M Angle of Brace i *Please Note:These calculations are for TOLCOT""components only.Use of any other components voids these calculations and the listing of the assembly. Least Rad.of Gyration 0.42"(11 mm) Seismic Brace Assembly Detail L/R Value 300 TOLCO flO ea UNARM SWAY BRACE Max Horizontal Load 582 lbs(264 kg) AT`"`""E"T Fastener Information !RACE f0'! Orientation to Connecting Surface NFPA Type H Fastener Type 1/2in.x 3 1/2in.Thru Bolt Diameter 1/2in r�, Length 3 1/2in. er TOLCO flO.1001 Maximum Load 330 lbs(150 kg) =war Brace Identification on Plans 4"Lateral Bracing Prying Factor N/A Brace Type Lateral[X] Longitudinal[ ] 4-Way[ ] Sprinkler System Load Calculation (Fpw=CpWp) Cp= ^_ 0.456 Diameter Type Length Total Length Weight Per Unit Length I Total Weight 4"(100 mm) Sch. 10 12.5 ft(3.8 m) 12.5 ft(3.8 m) 11.78 lb/ft(17.53 kg/m) 147 lbs(67 kg) 2.5"(65 mm) Sch. 10 36 ft(11 m) 36 ft(11 m) 5.89 lb/ft(8.77 kg/m) 212 lbs(96 kg) 2"(50 mm) Sch. 10 20 ft(6.1 m) 20 ft(6.1 m) 4.22 lb/ft(6.28 kg/m) 84 lbs(38 kg) Subtotal Weight 443 lbs(201 kg) Wp(incl. 15%) 509 lbs(231 kg) Main Size Type/Sch. Spacing(ft) I Total(Fpw) 232 lbs(105 kg) 4" Sch.10 12.5 Maximum Fpw per 18.5.5.2(if applicable) 1635 lb(741 kg) {TOLBraceTM Version 81 Use of TOLBraceTM is subject to terms and conditions per the end user license agreement TOLBraceTM Seismic Calculation Port Plastics Job#LC0917 7500 SW Tech Center Dr.#100 F-T•N Brace Identification 4"Lateral Bracing Brace Type(Per NFPA#13) NFPA Type H Braced Pipe(ft) 4"Sch.10 Steel Pipe Spacing of Brace 12'6"(3.81 m) Orientation of Brace Lateral Bracing Material 1"Sch.40 Maximum Brace Length 10'6"(3.2 m) Slenderness Ratio used for Load Calculation, 300 True Angle of Brace for Calculation 45° Type of Fastener 1/2in.x 3 1/2in.Thru Bolt Length of Fastener 3 1/2in. Summary of Pipe within Zone of Influence 4"Sch.10 Steel Pipe(101.6 mm) 12.5 ft(3.8 m) 2.5"Sch.10 Steel Pipe(63.5 mm) 36 ft(11 m) 2"Sch.10 Steel Pipe(50.8 mm) 20 ft(6.1 m) G-Factor Used 0.456 Allowance for Heads and Fittings 15% Conclusions Total Adjusted Load of Pipe in Zone of Influence 233 lbs(106 kg) Material Capacity 582 lbs(264 kg) Fastener Capacity 330 lbs(150 kg) Fig. 1001 Clamp 1414 lbs(641 kg) Fig.980- 1/2"Universal Swivel 1485 lbs(674 kg) Structural Member Wood Beam Calculations prepared by Alexander Funk *The description of the Structural Member is for informational purposes only. TOLBraceM software calculates the brace assembly only,not the structure it is attached to. Calculated with TOLBrace",8 Visit us at www.tolco.com TOLBraceTM Seismic Bracing Calculations V8.8.124 Contractor: Western States Fire Protectic Project Address: Port Plastics Address: 17500 SW 65th Ave. Lake Oswego,OR 97035 EST.N 7500 SW Tech Center Dr.#100 FbowingB siValdwide Phone: 503-305-3018 Portland,OR 97223 Licence: 241374 Job#LC0917 Calculations based on 2019 NFPA Pamphlet 913 Brace Information TOLCOTM Brace Components Maximum Brace Length 10's"(3.2 m) TOLCOTM Component Listed Load Adjusted Load Diameter of Brace 1 Fig.4L Clamp 2000 lbs(907 kg) 1414 lbs(641 kg) Fig.980-1/2"Universal Swive 2100 lbs(953 kg) 1485 lbs(674 kg) Type of Brace Sch.40 See Fastener Information 45°Min. *Calculation Based on CONCENTRIC Loading Angle of Brace *Please Note:These calculations are for TOLCOT*'components only.Use of any other components voids these calculations and the listing of the assembly. Least Rad.of Gyration 0.42"(11 mm) Seismic Brace Assembly Detail LJR Value 300 TOLCO FIG.980 Max Horizontal Load 582 lbs(264 kg) Fastener Information BRACE PIPE Orientation to Connecting Surface NFPA Type H Fastener Type 1/2in.x 3 1/2in.Thru Bolt _ TOLCO FIG.4L Diameter 1/2in. Length 3 1/2in. Maximum Load 330 lbs(150 41 � Brace Identification on Plans 4"Longitudinal Bracing Prying Factor N/A Brace Type Lateral[ ] Longitudinal[X] 4-Way[ ] Sprinkler System Load Calculation (Fpw=CpWp) Cp= 0.456 Diameter Type Length Total Length Weight Per Unit Length Total Weight 4"(100 mm) Sch. 10 50 ft(15.2 m) 50 ft(15.2 m) 11.78 lb/ft(17.53 kg/m) 589 lbs(267 kg) Subtotal Weight 589 lbs(267 kg) Wp(incl. 15%) 677 lbs(307 kg) Main Size Type/Sch. Spacing(ft) I Total(Fpw) 309 lbs(140 kg) 4" Sch.10 50 Maximum Fpw per 18.5.5.2(if applicable) N/A fTOLBracen,Version 81 Use of TOLBracem is subject to terms and conditions per the end user license agreement TOLBraceT" Seismic Calculations Port Plastics Job#LC0917 7500 SW Tech Center Dr.#100 E• Pow, errin ssWor+duade Brace Identification 4" Longitudinal Bracing Brace Type(Per NFPA#13) NFPA Type H Braced Pipe(ft) 4"Sch.10 Steel Pipe Spacing of Brace 50'0" (15.24 m) Orientation of Brace Longitudinal Bracing Material 1"Sch.40 Maximum Brace Length 10'6" (3.2 m) Slenderness Ratio used for Load Calculation 300 True Angle of Brace for Calculation 45° Type of Fastener 1/2in.x 3 1/2in.Thru Bolt Length of Fastener 3 1/2in. Summary of Pipe within Zone of Influence 4"Sch.10 Steel Pipe(101.6 mm) 150 ft(15.2 m) G-Factor Used 0.456 Allowance for Heads and Fittings 15% Conclusions Total Adjusted Load of Pipe in Zone of Influence 309 lbs(140 kg) Material Capacity 582 lbs(264 kg) Fastener Capacity 330 lbs(150 kg) Fig.4L Clamp 1414 lbs(641 kg) Fig.980- 1/2" Universal Swivel 1485 lbs(674 kg) Structural Member Wood Beam Calculations prepared by Alexander Funk *The description of the Structural Member is for informational purposes only. TOLBrace""software calculates the brace assembly only,not the structure it is attached to. Calculated with TOLBraceTM 8 Visit us at www.tolco.com TOLBraceTM Seismic Bracing Calculations V8.8.124 Contractor: Western States Fire Protectic Project Address: Port Plastics Address: 17500 SW 65th Ave. Lake Oswego,OR 97035 E_T•N 7500 SW Tech Center Dr.#100 Phone: 503-305-3018 '>aBuavrassittri�dxxcle Portland,OR 97223 Licence: 241374 Job#LC0917 Calculations based on 2019 NFPA Pamphlet#13 Brace Information TOLCOTM Brace Components Maximum Brace Length 10's"(3.2 rn) TOLCOTM Component Listed Load Adjusted Load Diameter of Brace 1" Fig. 1001 Clamp 2000 lbs(907 kg) 1414 lbs(641 kg) Fig.980-1/2"Universal Swive 2100 lbs(953 kg) 1485 lbs(674 kg) Type of Brace Sch.40 ---- - - - See Fastener Information Angle of Brace 45°Min. *Calculation Based on CONCENTRIC Loading *Please Note:These calculations are for TOLCOT*'components only.Use of any other components voids these calculations and the listing of the assembly. Least Rad.of Gyration 0.42"i11 mat) Seismic Brace Assembly Detail L/R Value 300 TACO FIG 900 Max Horizontal Load 582 lbs 264 k UNIVERSAL A*TT C Fastener Information MACE PPE Orientation to Connecting Surface NFPA Type H Fastener Type 1/2in.x 3 1/2in.Thru Bolt Diameter01;# 1/2in. Length 3 1/2in. '107/ Maximum Load lbs 4, TOLCO F10 700'330 FAO CLAMP FOR 150 kg) 9WAYe0ACNO Brace Identification on Plans 2TWz"Lateral Bracing Prying Factor N/A Brace Type Lateral[X] Longitudinal[ ] 4-Way[ ] Sprinkler System Load Calculation (Fpw=CpWp) Cp= __ 0.456 Diameter Type Length Total Length Weight Per Unit Length Total Weight 2.5"(65 mm) ,Sch. 10 40 ft(12.2 m) 40 ft(12.2 m) 5.89 lb/ft(8.77 kg/m) 236 lbs(107 kg) Subtotal Weight 236 lbs(107 kg) Wp(incl. 15%) 271 lbs(123 kg) Main Size Type/Sch. Spacing(ft) I Total(Fpw) 124 lbs(56 kg) 2.5" Sch.10 40 Maximum Fpw per 18.5.5.2(if applicable) 301 lb(136 kg) (TOLBraceTM Version 8) Use of TOLBraceT"is subject to terms and conditions per the end user license agreement TOLBracer" Seismic Calculations Port Plastics Job#LC0917 7500 SW Tech Center Dr.#100 E_ � Pbuw+ing�rrir�ussNkrfdudde Brace Identification 21/2" Lateral Bracing Brace Type(Per NFPA#13) NFPA Type H Braced Pipe(ft) 2.5" Sch.10 Steel Pipe Spacing of Brace 40'0" (12.19 m) Orientation of Brace Lateral Bracing Material 1" Sch.40 Maximum Brace Length 10'6" (3.2 m) Slenderness Ratio used for Load Calculation 300 True Angle of Brace for Calculation 45° Type of Fastener 1/2in.x 3 1/2in.Thru Bolt Length of Fastener 3 1/2in. Summary of Pipe within Zone of Influence 2.5"Sch.10 Steel Pipe(63.5 mm) 1406(12.2 m) G-Factor Used 0.456 Allowance for Heads and Fittings 15% Conclusions Total Adjusted Load of Pipe in Zone of Influence 124 lbs(56 kg) Material Capacity 582 lbs(264 kg) Fastener Capacity 330 lbs(150 kg) Fig. 1001 Clamp 1414 lbs(641 kg) Fig.980- 1/2" Universal Swivel 1485 lbs(674 kg) Structural Member Wood Beam Calculations prepared by Alexander Funk *The description of the Structural Member is for informational purposes only. TOLBrace'"software calculates the brace assembly only,not the structure it is attached to. Calculated with TOLBracer"8 Visit us at www.tolco.com TOLBraceTM Seismic Bracing Calculations V8.8.124 Contractor: Western States Fire Protectia Project Address: Port Plastics17500 SW j Address: Lake Oswego,hOR 97035 E_T•N 7500 SW Tech Center Dr.#100 Pawing BusinsssiNattivide Phone: 503-305-3018 Portland,OR 97223 Licence: 241374 Job#LC0917 Calculations based on 2019 NFPA Pamphlet#13 Brace Information TOLCOTM Brace Components Maximum Brace Length 10'6"(3.2 m) TOLCOTM Component Listed Load Adjusted Load Diameter of Brace 1" Fig.4L Clamp 2000 lbs(907 kg) 1414 lbs(641 kg) Fig.980-1/2"Universal SwivE 2100 lbs(953 kg) 1485 lbs(674 kg) Type of Brace Sch.40 YP See Fastener Information 45°Min. "Calculation Based on CONCENTRIC Loading Angle of Brace *Please Note:These calculations are for TOLCOTM components only.Use of any other components voids these calculations and the listing of the assembly. Least Rad.of Gyration 0.42"(11 mm) Seismic Brace Assembly Detail LJR Value 300 TOLCO FIG.980 �. Max Horizontal Load 582 lbs 2_64 k %O I� Fastener Information BRACE PIPE Orientation to Connecting Surface NFPA Type E Fastener Type 1/2in.x 3 1/2in.Thru Bolt 40• TOLCO FIG.4L Diameter 1/2in. Length 3 1/2in. Maximum Load 350 lbs(159 kg) I Brace Identification on Plans 2'/"Longitudinal Bracing Prying Factor N/A Brace Type Lateral[ ] Longitudinal[X] 4-Way[ ] Sprinkler System Load Calculation (Fpw=CpWp) Cp= _�.0.456 Diameter Type Length Total Length Weight Per Unit Length Total Weight 2.5"(65 mm) Sch. 10 80 ft(24.4 m) 80 ft(24.4 m) 5.89 lb/ft(8.77 kg/m) 471 lbs(214 kg) Subtotal Weight 471 lbs(214 kg) Wp(incl.15%) 542 lbs(246 kg) Main Size Type/Sch. Spacing(ft) I Total(Fpw) 247 lbs(112 kg) 2.5" Sch.10 80 Maximum Fpw per 18.5.5.2(if applicable) N/A 4TOLBrace'"'Version 8) Use of TOLBraceTM is subject to terms and conditions per the end user license agreement " TOLBraceTM' Seismic Calculations Port Plastics Job#LC0917 7500 SW Tech Center Dr.#100 E.T Pbtew*q 8rrir& 4 ksfda6dia Brace Identification 21/2" Longitudinal Bracing Brace Type(Per NFPA#13) NFPA Type E Braced Pipe(ft) 2.5" Sch.10 Steel Pipe Spacing of Brace 80'0"(24.38 m) Orientation of Brace Longitudinal Bracing Material 1"Sch.40 Maximum Brace Length 10'6" (3.2 m) Slenderness Ratio used for Load Calculation 300 True Angle of Brace for Calculation 45° Type of Fastener 1/2in.x 3 1/2in.Thru Bolt Length of Fastener 3 1/2in. Summary of Pipe within Zone of Influence 2.5"Sch.10 Steel Pipe(63.5 mm) 180 ft(24.4 m) G-Factor Used 0.456 Allowance for Heads and Fittings 15% Conclusions Total Adjusted Load of Pipe in Zone of Influence 247 lbs(112 kg) Material Capacity 582 lbs(264 kg) Fastener Capacity 350 lbs(159 kg) Fig.4L Clamp 1414 lbs(641 kg) Fig.980- 1/2" Universal Swivel 1485 lbs(674 kg) Structural Member Wood Beam Calculations prepared by Alexander Funk *The description of the Structural Member is for informational purposes only. TOLBrace""software calculates the brace assembly only,not the structure it is attached to. Calculated with TOLBrace'"8 Visit us at www.tolco.com