FPS2025-00044 Approved plans
Rcv'd 5/7/2025 - AP SCOPE OF WORK: FACP REPLACEMENT FIRE ALARM c, 1. THIS IS A REPLACEMENT OF AN EXISTING FIRE ALARM PANEL THAT IS STARTING TO HAVECY SEQUENCE z0 CV ISSUES AND NEEDS TO BE REPLACED WITH A NEW FACP. OF < z in o z Cn � FIRE ALARM LEGEND & MATERIAL LIST Il 2. REPLACE EXISTING FACP WITH NEW FIRELITE ADDRESSABLE FACP. RECONNECT EXISTING OPERATIONS 0 0 Q 120VAC DEDICATED CIRCUIT. PROVIDE TWO NEW BATTERIES 12V-8AH. UPGRADE EXISTING -D Q z ( p CELLULAR COMMUNICATOR AND RECONNECT TO EXISTING MONITORING STATION. REUSE < Cn > C7 SYMBOL DESCRIPTION MANUFACTURER PART NUMBER QTY. rill EXISTING CABLES AND EXISTING DEVICE LOCATIONS. L 0 w z Cn <1 FACP FIRE ALARM CONTROL PANEL (ADDRESSABLE) FIRELITE ES-50X 1 a 3. UPGRADE EXISTING SMOKE DETECTOR AND PULL STATION TO ADDRESSABLE VERSION. NOTES: Q p INSTALL ADDRESSABLE MONITOR MODULES AT SPRINKLER RISER. REUSE EXISTING CABLES AND DEVICE LOCATIONS 0 0 - C CENTRAL STATION ALARM SERVICE Q 0 G_ CELL FIRE CELLULAR COMMUNICATOR STARLINK SLE-LTEV-FIRE 1 a Li 4. RECONNECT EXISTING BELL CIRCUIT TO NEW FACP. UPDATE END OF LINE RESISTORS. TO RECEIVE SEPARATE & DISTINCT Q O 0 0) Ow LO I H -I DOC FIRE ALARM DOCUMENTS CABINET MIER PRODUCTS DOCBOX 1 CV CV 5. INSTALL FIRE ALARM DOCUMENTS CABINET NEXT TO FACP. SIGNALS AS FOLLOWS: o D L w D o CV A. ALARM 0 < Q D [Y ❑F PULL STATION (ADDRESSABLE) FIRELITE BG12LX 1 It 6. TEST FIRE ALARM SYSTEM AND CONFIRM SIGNALS RECEIVED. PRIOR TO FINAL INSPECTION Cn Q Cn 1-� w I- ~ I-B. SUPERVISORY THE SYSTEM SHALL BE FULLY TESTED. PREPARE AND FURNISH SYSTEM RECORD OF } � � � � U OS < 0 SMOKE DETECTOR (ADDRESSABLE) FIRELITE SD365 1 COMPLETION FOR FINAL INSPECTION. C. TROUBLE -1 z z z z o O� w w w MMIl ADDRESSABLE MONITOR MODULE FIRELITE MMF-300 2 ACTIVATION OF SMOKE DETECTOR 0 0 0 TS WF SPRINKLER VALVE TAMPER &WATER FLOW SWITCHES BY OTHERS EXIST ACTIVATION OF MANUAL PULL STATION # 0 0 AI 10, EKI HORN-STROBE SYSTEM SENSOR P2R EXIST IMPORTANT NOTES ACTIVATION OF SPRINKLER WATER FLOW SWITCH 0 # tl [BATT! BACK UP BATTERIES (2x) 12V-8AH 1. DO NOT START INSTALLATION BEFORE SYSTEM IS APPROVED BY THE AHJ. ACTIVATION OF SPRINKLER VALVE TAMPER SWITCH TROUBLE CONDITION AT COMMUNICATOR 0 # 2. INSTALLATION TO BE DONE PER NFPA 72 (FIRE ALARM & SIGNALING CODE 2019)AND ALL OTHER APPLICABLE CODES & STANDARDS. TROUBLE CONDITION AT PANEL # # 3. VERIFY EXACT LOCATIONS AND DIMENSIONS OF PANELS AND DEVICES BEFORE ROUGH IN. LOSS OF AC POWER AT PANEL ! ! 4. VERIFY ALL WIRING CONNECTIONS, BACKBOXES, CONDUITS, &CABLE TYPES BEFORE INSTALLATION. PLEASE PROVIDE COMPLETED cf.; NFPA 72 RECORD OF COMPLETION o AT FINAL INSPECTION r (--- 5 ...._ .._....,, =---Y---- . . Ce SPRINKLER RISER (E) (E) ELECTRIC WF TS MECH WOMEN MEN K1 003 OFFICE MM MM OS 001 002 004 !� w� 1.7) E FACP c) Approved plans shall be on job site. WHOLE FOODS TENANT PHARMACY LUNCH ► WAREHOUSE AREA CONF r APPROVED ` VI OFFICE 110 STORAGE ___) , 1 NCITY OF TIGARD _ Y I - . " REVIEWED FOR CODE COMPLIANCE W 0. . TIGARD Approved\: [A ] OTC: [ ] 0Q�// L.L � By: tomh Address: 12240 Scholls ferry Q 0 O Date: 5/7/2025 Suite No: V 0— Permit No: FPS2025-000441 >- H N I— (f) 0_ Lu N U ( M LI_ o 0 VALIDITY OF PERMIT Qis) I 0 THE ISSUANCE OF A PERMIT BASED ON CONSTRUCTION DOCUMENTS w Z � < AND OTHER DATA SHALL NOT PREVENT THE CODE OFFICAL FROM SALES 12 0 rY REQUIRING THE CORRECTION OF ERRORS. ORSC 105.4 AREA < Q —I � LLB � N ce II LL 4, t 4 DATE: 4-12-25 SCALE: AS SHOWN DRAWN BY: NLH PROJECT NUMBER: SHEET: SIDE EXIT MAIN ENTRY 1 OF 2 , i) .. ,_..x.: --..... EID FLOOR PLAN - EXISTING FIRE ALARM LAYOUT N SCALE:1/8" = 1' 4 s * ! 4 c9 CV 70 0 11 in C r= z IMPORTANT NOTES (11 0 a PC 1. VERIFY WIRING CONNECTIONS IN INSTALLATION MANUALS BEFORE ROUGH-IN. LO CV 2. VERIFY MOUNTING HEIGHTS WITH AHJ BEFORE ROUGH-IN. CV CV STARLINK It as CELL DIALER L) (UPGRADE) 2x CAT6— A/C SUPPLY -.._ 4,.—.- DIFFUSER OR INTAKE CEILING (MIN) iiiiiii /� /iiiiiii//iiiiiiiiiiiiiiiiiii���iiiiiiiiiiiiii ///// \\\\\ �iiiiiiiiiiiiiiiiiiiiiiii �iiiiiiiiiiiiiiiiiiiiiiiii //i///hill/, R FIR 1 SMOKE SMOKE CEILING 3 DETECTOR DETECTOR EXIST SPRINKLER SPRINKLER ABOVE ELEC HORN / (MIN) RISER RISER FACP ROOM STROBE MM MM F SLC CKTS WF TS 004 WALL 0 001 001 HORN / l (UPGRADED) STROBE `FO FIRE FIRE ALARM FACP DOC BOX ES-50X EXIST SYNCHRONIZE ALL DEVICES NAC CKT#1 TO EXISTING NOTIFICATION z NEXT TO FACP 0 0 U) w ce NAC CKT#2 SPARE (2x) 12V-8AH 90" TYPICAL FINISHED BATTERIES J 5' — WALL (MAX) REPLACED AT EXISTING FACP FIRE ALARMAL MANUAL PULL • FIRE ALARM PANEL & DIALER - RISER DAIAGRAM STATION (VERIFY EXACT LOCATIONS, WIRINGS, AND CONNECTIONS) lb 0 42" MAX (ADA) FINISHED FLOOR _ LI..I CABLE LEGEND 0 0 < 0 FIRE ALARM TYPICAL DEVICE MOUNTING HEIGHTS A ZONE 16AWG, 2 CONDUCTOR, FPLP p� DC Q B NAC 14 AWG, 2 CONDUCTOR, FPLP Q 0- ce (VERIFY EXACT PLACEMENT BEFORE INSTALL) C >- C ANN/COM 16 AWG, 4 CONDUCTOR, FPLP N cn 0- w N u N (>;) � U J Ln 0)( M u_ o 0 Q is) Q Z w Q FIRE ALARM GENERAL INFORMATION w 0 1-1 BATTERY CALCULATIONS FOR FACP A. ALL WIRING TO BE IN ACCORDANCE WITH NEC, LOCAL AUTHORITIES, AND LL < J 0 APPLICABLE CODES. EQUIPMENT GROUNDING CONDUCTORS, IF NEEDED, ARE LLI N SUPERV. ALARM TOTAL SUP. TOTAL ALARM NOT SHOWN ON THE DRAWING, UNLESS OTHERWISE NOTED. E- a N QTY MODULE DESCRIPTION CURRENT,A CURRENT,A CURRENT,A CURRENT,A I l IL. I 1 ES-50X FIRELITE FACP WITH IPOTS CARD 0.141000 0.257000 0.141000 0.257000 B. DISCONNECT POWER BEFORE SERVICING SYSTEM. w 1 SD365 FIRELITE ADDRESSABLE SMOKE DETECTOR 0.000200 0.004500 0.000200 0.004500Ce 1 BG12-LX FIRELITE ADDRESSABLE PULL STATION 0.000375 0.005000 0.000375 0.005000 C. ALL DC ALARM SIGNALS ARE MARKED SHOWING POLARITY OF OPERATION. THE POLARITY REVERSING DC ALARM INDICATING CIRCUITS ARE MARKED I� 2 MMF-300 FIRELITE ADDRESSABLE MONITOR MODULE 0.000375 0.005000 0.000750 0.010000 SHOWING POLARITY OF SUPERVISION. CONNECT ONLY 24VDC POLARIZED LL 1 SLE-MAX2 STARLINK FIRE COMMUNICATOR 0.085000 0.200000 0.085000 0.200000 ALARM SIGNAL. NOTIFICATION APPLIANCES CIRCUITS D. ALL SUPPLEMENTARY POWER MUST BE FUSED. USE ONLY UL LISTED POWER TOTAL CURRENT NAC CIRCUIT#1 -EXIST 0.176 SUPPLY FOR FIRE PROTECTIVE SERVICE. TOTAL CURRENT NAC CIRCUIT#2-SPARE E. INSTALLATION TO BE PER NFPA 72 (2019). 4 TOTAL ALARM CURRENT 0.653 TOTAL SUPERVISORY CURRENT 0.227 F. SEE INSTALLATION INSTRUCTIONS SHEET PACKAGED WITH FIRE ALARM DATE: TOTAL STANDBY HOURS 24 SYSTEM DEVICES FOR ADDITIONAL INFORMATION. 4-12-25 TOTAL SUPERVISORY CAPACITY 5.456 G. SEE DATA MANUAL(S) FOR ADDITIONAL INFORMATION. SCALE: ALARM PERIOD IN MINUTES 10 AS SHOWN TOTAL ALARM CAPACITY 0.109 H. MAKE SURE THAT ALL POWER-LIMITED/CLASS 2 WIRING IS SEPARATED AT TOTAL ALARM AND SUPERVISORY CAPACITY 5.565 LEAST 0.25 INCH FROM ANY WIRING THAT IS NOT POWER-LIMITED. DRAWN BY: TOTAL AMP HOURS REQUIRED(AFTER 20%DERATING FACTOR) 6.677 I. LOOP WIRE IN ALL J BOXES FROM TOP OF CAN TO BOTTOM OF CAN BACK TO NLH PROVIDE TWO (2) 12V-8AH BATTERIES TOP. PROJECT NUMBER: J. TO PREVENT CONFUSION AND POSSIBLE ERRORS, ALL CONDUCTORS SHOULD BE TAGGED OR OTHERWISE CODED AND LOGGED, AT INSTALLATION, TO IDENTIFY CIRCUIT ASSIGNMENT, POLARITY, AND WHETHER THE WIRING IS OUTGOING OR RETURN. SHEET: 2OF2 K. LEAVE ADEQUATE SLACK IN THE WIRING TO ALLOW FOR TROUBLE SHOOTING. 4 IP F A _ 2 4 4 , t Rcv'd 5/7/2025 -AP APPROVED DF-60953:C ES-50X Fire•LITe°Al arms Intelligent Addressable FACP with Communicator by Honeywell Addressable Fire Alarm Control Panels General The ES-50X is the latest intelligent addressable fire alarm control panel (FACP)from Fire•Lite Alarms and is a direct replacement for the MS-9050UD/LS. The ES-50X comes with a pre-installed communi-cator and supports up to 50 addressable devices in any combination of detectors or modules. With an extensive list of powerful features, the ES-50X programs just like Fire•Lite's other addressable panels, yet fits into applications previously served only by conventional panels. The pre-installed IPOTS-COM is a dual technology (POTS and IP) s = communicator.The POTS transmits system status(alarms,troubles, — AC loss, etc.)to a Central Station via the public switched telephone network.The IP communicator's Internet monitoring capability sends alarm signals over the Internet saving the monthly cost of two dedi- cated business telephone lines. Although not required, the second- ary telephone line may be retained providing backup communication over the public switched telephone line. Optional cellular reporting is available using the CELL-MOD or CELL-CAB-FL. Remote and local programming of the control panel is possible using the FS-Tools Upload/Download utility. Programming databases can be uploaded/downloaded via the panel's USB port(and USB cable) or via an ethernet connection using the IPOTS-COM communicator. The USB port also allows for the download or upload of the entire program, history file, walk-test data, current status and system volt- • Maintenance alert warns when smoke detector dust accumula- ages by means of a USB flash drive. tion is excessive The power supply and all electronics are contained on a circuit • One-person audible or silent walktest with walktest log&printout board supported on a new quick install chassis and housed in a • System alarm verification selection per detector point metal cabinet. Available accessories include local and remote • PAS (Positive Alarm Sequence) and Pre-signal per point (NFPA upload/download software, remote annunciators, and reverse polar- 72 compliant) ity/city box transmitter(4XTMF). • Up to 16 ANN-BUS annunciators-8 per each ANN-Bus Features • Remote Acknowledge, Alarm Silence, Reset and Drill via addressable modules or remote annunciator • Listed to UL Standard 864, 10th edition • Upload/Download of program and data via USB with optional FS- • Pre-installed IPOTS-COM Ethernet IP and POTS(Plain Old Tele- Tools Programming Utility phone Service)Central Station Communicator • Optional CELL-MOD or CELL-CAB-FL GSM Central Station SLC COMMUNICATION LOOP Communicator overAlarmNet® • Supports LiteSpeed TM and CLIP protocols • Compatible with SWIFT®wireless devices • SLC operates up to 10,000 ft. (3,000 m) in LiteSpeed mode with • Auto-programming (learn mode) reduces installation time. twisted, unshielded wire Reports two devices set to the same address • Single addressable SLC loop which meets NFPA Class B and • Two independently programmable, built-in Style Z (Class A) or Class A requirements Style Y(Class B)NAC circuits • 50 addressable device capacity(any combination of addressable • Selectable strobe synchronization for System Sensor, Wheelock, detectors and modules) and Gentex devices • Compatible with Fire•Lite's addressable devices (refer to the • Notification Appliance Circuit End of Line resistor matching SLC Wiring Manual) • Four programmable function keys for ease of maintenance NOTIFICATION APPLIANCE CIRCUITS(NACS) • Two programmable relays and one fixed trouble relay • Two independently programmable output circuits. Circuits can be • Built-in Programmer configured for the following outputs: • Integral 80-character LCD display with backlighting —Style Y(Class B) • Real-time clock/calendar with automatic daylight savings control —Style Z(Class A) • History file with 1,000 event capacity • Silence Inhibit and Autosilence timer options • Addressable sounder base • Continuous, March Time, Temporal, or California code for main • Multi-criteria detector (smoke, heat, CO) with programmable circuit board NACs with two-stage capability response • Selectable strobe synchronization per NAC • Control module delay timer • 2.5 A special application,250mA regulated,total power for NACs • Automatic detector sensitivity testing(NFPA 72 compliant) NOTE:Maximum or total 24VDC system power shared between all NAC • Automatic device type-code verification circuits and the ANN-BUS is 2.7 A • Point trouble identification PROGRAMMING AND SOFTWARE • Waterflow selection per module point • Alarm verification selection per detector point • Autoprogramming(learn mode)reduces installation time DF-60953:C•7/16/2018—Page 1 of 4 • Custom English labels (per point) may be manually entered or OPTIONAL MODULES selected from an internal library file 4XTMF Reverse Polarity Transmitter Module: Provides a super- • Two programmable Form-C relay outputs vised output for local energy municipal box transmitter, alarm and • 50 software zones trouble. Includes a disable switch and disable trouble LED. • Continuous fire protection during online programming • Program Check automatically catches common errors not linked COMPATIBLE ANNUNCIATORS to any zone or input point ANN-80: Remote, red LCD annunciator mimics the information dis- • OFFLINE PROGRAMMING: Create the entire program in your played on the FACP LCD display. Recommended wire type is un- office using FS-Tools,a Windows®-based software package,and shielded. upload/download system programming locally. Offline program- ANN-100: Remote LCD annunciator mimics the information dis- ming requires an ethernet connection. FS-Tools is available on played on the FACP LCD display. Recommended wire type is un- www.firelite.com. shielded. For use in FM applications only. User interface ANN-I/O: LED Driver Module provides connections to a user sup- LED INDICATORS plied graphic annunciator. (See DF-52430.) ANN-LED: Annunciator Module provides three LEDs for each zone: • Fire Alarm(red) Alarm,Trouble,and Supervisory.Ships with red enclosure. (See DF- • CO Alarm(red) 60241.) • AC Power(green) ANN-RLED: Provides alarm(red)indicators for up to 30 input zones • Supervisory(yellow) or addressable points. (See DF-60241.) • Trouble(yellow) ANN-RLY: Relay Module provides 10 programmable Form-C relays. • Ground fault(yellow) Can be mounted inside the cabinet. (See DF-52431.) • Battery fault(yellow) ANN-S/PG: Serial/Parallel Printer Gateway module provides a con- nection for a serial or parallel printer. (See DF-52429.) • Disabled(yellow) • Maintenance(yellow) ADDRESSABLE DEVICES • Communication (yellow) All feature a polling LED and rotary switches for addressing. • Alarm Silenced (yellow) SD365:Addressable low-profile photoelectric smoke detector. Lite- Speed only. • F1-F4 Programmable Function Keys(yellow) SD365-IV: Addressable low-profile photoelectric smoke detector. KEYPAD Ivory. LiteSpeed and CLIP mode. • 16 key alpha-numeric pad SD365T:Addressable low-profile photoelectric smoke detector with • Acknowledge thermal sensor. LiteSpeed only. • Alarm Silence SD365T-IV: Addressable low-profile photoelectric smoke detector • Drill (Manual Evacuate) with thermal sensor. Ivory. LiteSpeed and CLIP mode. • Four(4)programmable function keys SD365R: Remote test capable addressable photoelectric smoke detector for use with DNR(W)duct detector housing. LiteSpeed only. • Reset(lamp test) SD365R-IV: Remote test capable addressable photoelectric smoke Product Line Information detector for use with DNR(W) duct detector housing. Ivory. Lite- Speed and CLIP mode. ES-50X:Addressable Fire Alarm Control Panel with one SLC loop. H365: Low profile 135°F fixed thermal sensor. LiteSpeed only. Includes main circuit board with display, pre-installed IPOTS-COM communicator, chassis with transformer, backbox with door, plastic H365-IV: Low-profile 135°F fixed thermal sensor. Ivory. LiteSpeed bag containing screws, cables, key, etc. (For ES-50XC, refer to DF- and CLIP mode. 60954.) H365R: Low-profile, intelligent, rate-of-rise thermal sensor. Lite- FS-Tools: Programming software for Windows®-based PC com- Speed only. puter.Available for download at www.firelite.com. H365R-IV: Low-profile, intelligent, rate-of-rise thermal sensor. Ivory. CELL-CAB-FL/CELL-MOD: Optional GSM communicators. LiteSpeed and CLIP mode. IPOTS-COM: Dual technology (POTS and IP) communicator. H365HT: Low-profile intelligent 190°F/88°C fixed thermal sensor. (replacement board) LiteSpeed only. DP-ES-R: Optional dress panel for the ES-50X. H365HT-IV: Low-profile intelligent 190°F/88°C fixed thermal sensor. TR-CE:Optional trim ring for semi-flush mounting. Ivory. LiteSpeed and CLIP mode. BB-2F:Optional cabinet for one or two modules. Legacy Devices BB-6F: Optional cabinet for up to six modules mounted on CHS-6 SD355:Addressable low-profile photoelectric smoke detector. chassis. SD355T:Addressable low-profile photoelectric smoke detector with BB-26: Battery backbox,holds up to two 25 AH batteries&CHG-75. thermal sensor. BB-55F: Battery box, houses two 55 AH batteries SD355R: Remote test capable addressable photoelectric smoke CHS-6:Chassis,mounts up to six multi-modules in a BB-6F cabinet. detector for use with DNR(W)duct detector housing. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. SD355CO:Addressable, low-profile device that provides fire, heat, CHG-120F: Remote battery charging system for lead-acid batteries and carbon monoxide(CO)detection. with a rating of 55 to 120 AH. Requires additional BB-55F for mount- H355: Fast-response, low-profile heat detector. ing. H355R: Fast-response, low-profile heat detector with rate-of-rise BAT Series: Batteries,see data sheet DF-52397. option. PRN Series: UL listed compatible event printer. Uses tractor-fed H355HT: Fast-response, low-profile heat detector that activates at paper. 190°F/88°C. Page 2 of 4—DF-60953:C•7/16/2018 AD355: Low-profile, intelligent, "Adapt" multi-sensor detector W-BG12LX: LiteSpeed Intelligent wireless pull station. (B350LP base included). WAV-RL,WAV-WL,WAV-CRL,WAV-CWL: LiteSpeed Intelligent AV B200S: Programmable,addressable sounder base bases. B200SR:Addressable sounder base. W-USB: Wireless USB radio/antenna dongle that plugs into the BEAM355: Intelligent beam smoke detector. USB port of a PC running SWIFT Tools. BEAM355S: Intelligent beam smoke detector with integral sensitiv- ity test. Gateway and devices.Available for download from firelite.com. InnovairFlex low flow non relay duct detector housing; NOTE: For more information on Compatible Addressable Devices for D355PL: I includes S no R. use with the ES-50X, see the following data sheets (document num- bers): SD365 Series (DF-61010), H365 Series (DF-61011), AD355 DNR: InnovairFlex low-flow non-relay duct-detector housing. (Order (DF-52386), BG-12LX(DF-52013), CMF-300-6 (DF-52365), CRF-300-6 SD355R/SD365R separately.) (DF-52374), CMF/CRF Series (DF-52130), CP355 (DF-52383), H355 DNRW: InnovairFlex low-flow non-relay duct-detector housing, with Series (DF-52385), 1300 (DF-52389), ISO-6 (DF-60485), MMF-300 NEMA-4 rating.Watertight. (Order SD355R/SD365R separately.) Series/MDF-300 (DF-52121), MMF-300-10 (DF-52347), MMF-302-6 Modules (DF-52356), SD355/SD355T (DF-52384), and SLC Wiring Manual Addressable (51309). MMF-300: Addressable Monitor Module for one zone of normally- NOTE:Legacy 300 Series detection devices such as the CP300/CP350, open dry-contact initiating devices. Mounts in standard 4.0" (10.16 SD300(T)/SD350(T)and older modules such as the M300, M301, M302, cm.) box. Includes plastic cover plate and end-of-line resistor. Mod- C304, and BG-10LX are not compatible with LiteSpeed polling. If the ule may be configured for either a Style B(Class B)or Style D(Class SLC contains one of these devices, polling must be set for standard A) IDC. CLIP protocol. Please consult factory for further information on previous MDF-300: Dual Monitor Module. Same as MMF-300 except it pro 300 Series devices. vides two Style B(Class B)only IDCs. ADDRESSABLE DEVICE ACCESSORIES MMF-301: Miniature version of MMF-300. Excludes LED and Style End-of-Line Resistor Assembly (R-47K and R-3.9K): The D option. Connects with wire pigtails. May mount in device backbox. 47k ohm assembly supervises the MMF-300, MDF-300, MMF-301, MMF-302: Similar to MMF-300.Addressable Monitor Module for one and CMF-300 module circuits. The 3.9k ohm assembly supervises zone of conventional two-wire detectors. Requires resettable 24 the MMF-302 module circuit.These resistors are included with each VDC power. Refer to the Device Compatibility Document for listed module. compatible devices and quantity limitation. Power Supervision Relay: Supervises the power to 4-wire smoke CMF-300: Addressable Control Module for one Style Y/Z (Class B/ detectors and notification appliances. A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10.16 cm.) electrical box. NAC option requires Wiring Requirements external 24 VDC to power notification appliances. CRF-300: Addressable relay module containing two isolated sets of While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair o the ted pair panel minimize details. the effects of electrical interfer- Form-C contacts, which operate as a DPDT switch. Mounts directly ence. Refer to a 4.0"(10.16 cm.)box, surface mount using the SMB500. tomanual for wiring BG-12LX: Addressable manual pull station with interface module mounted inside. 1300:This module isolates the SLC loop from short circuit conditions (required for Style 6 or 7 operation). ISO-6: Six-fault isolator module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. SMB500: Used to mount all modules except MMF-301 and M301. MMF-300-10: Ten-input monitor module. Mount one or two modules in a BB-2F cabinet(optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. MMF-302-6: Six-zone interface module. Mount one or two modules in a BB-2F cabinet(optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. CMF-300-6: Six-circuit supervised control module. Mount one or two modules in a BB-2F cabinet(optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. CRF-300-6: Six-relay control module(Form-C relays). Mount one or two modules in a BB-2F cabinet(optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. SWIFT Wireless Devices W-GATE: LiteSpeed Wireless Gateway W-SD355: LiteSpeed intelligent,wireless photo detector. W-H355R: LiteSpeed intelligent wireless rate of rise (135°) heat detector. W-SD355T: intelligent wireless photo/heat detector. W-H355: LiteSpeed intelligent wireless fixed-temperature (135°) heat detector. W-MMF: LiteSpeed Intelligent wireless monitor module. W-CRF: LiteSpeed Intelligent wireless relay module. DF-60953:C•7/16/2018—Page 3 of 4 SYSTEM SPECIFICATIONS System Capacity Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0—49°C/32 • Intelligent Signaling Line Circuits 1 —120°F and at a relative humidity 93%±2% RH(noncondensing)at • Addressable device capacity 50 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's • Programmable software zones 50 standby batteries and the electronic components may be adversely • Annunciators 16 affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15—27°C/60- Electrical Specifications 80°F. AC Power: Operates in either 120 or 240 VAC, 50/60 Hz, 3.25 A, auto-sensing- no switch required. Wire size: minimum 14 AWG NFPA Standards (2.00 mm2) with 600 V insulation. Nonpower-limited, supervised. The ES-50X complies with the following NFPA 72 Fire Alarm Sys- Battery: Two 12 V 18 AH lead-acid batteries. Battery Charger tems requirements: Capacity: 7-18 AH (ES-50X cabinet holds maximum of two 18 AH —LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervi- batteries.) sory). Communication Loop: Supervised and power-limited. —AUXILIARY (Automatic, Manual and Waterflow) (requires Notification Appliance Circuits: Terminal Block provides connec- 4XTMF). tions for two NACs, Style Y (Class B) or Style Z (Class A). Special —REMOTE STATION (Automatic, Manual and Waterflow) Application power. Power-limited, supervised circuitry. Maximum (Where a DACT is not accepted,the alarm,trouble and supervi- signaling current per circuit: 2.5 amps special application, 250mA sory relays may be connected to UL 864 listed transmitters. For regulated. End-of-Line Resistor: 4.7k ohm, '/z watt (P/N 71252 UL reverse polarity signaling of alarm and trouble, 4XTMF is listed)for Style Y(Class B) NAC; system capable of 1.9 kf2-22 kf2 required.) ELR range. Refer to the Fire•Lite Device Compatibility Document for —PROPRIETARY(Automatic, Manual and Waterflow). listed compatible devices. —CENTRAL STATION (Automatic, Manual and Waterflow, and Two Programmable Relays and One Fixed Trouble Relay: Con- Sprinkler Supervised). tact rating: 2.0 A @ 30 VDC (resistive), 0.5 A @ 30 VAC (resistive). —OT, PSDN (Other Technologies, Packet-switched Data Net- Form-C relays, non-power-limited, non-supervised. work) Cabinet Specifications —IBC 2012, IBC 2009,IBC 2006, IBC 2003,IBC 2000(Seismic). —CBC 2007(Seismic) Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.72" (1.82 cm.)deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 Agency Listings and Approvals cm.) wide x 5.25" (13.34 cm.) deep. Trim Ring (TR-CE): 22.00" (55.88 cm.)high x 19.65"(49.91 cm.)wide. The listings and approvals below apply to the basic ES-50X control panel. In some cases, certain modules may not be listed by certain Shipping Specifications approval agencies, or listing may be in process. Consult factory for latest listing status. Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) high • UL:S624 x 22.5"(57.15 cm.)wide x 8.5"(21.59 cm.)deep. • FM approved • CSFM: 7165-0075:0500 • FDNY: COA#6261 NOTE:See DF-60954 for ULC-listed model. AlarmNet®, Fire-Lite®Alarms, SWIFT®, and System Sensor®are registered trademarks of Honeywell International Inc.Microsoft®and Windows®are registered trademarks of the Microsoft Corporation. ©2018 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. ENGINEERING S MANUFACTURING QUALITY SYSTEMS For more information,contact Fire•Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. Country of Origin:USA www.firelite.com Page 4 of 4—DF-60953:C•7/16/2018 *Lmier ,I�.r,.. PRODUCTS, INC. 4-,s,,, DocBoxEs &i. mi—Ammiow FThe door can be left blank, or - i,,,,,a.iu, one of the three In Mit"'•"d labels may be .r. I4lirtrrrtw-. ”Tt_,r -- _ used. r II1i, ) .- ( # , BW DocBox (15"Wx 13"Hx 4"D) • UL/c-UL Listed imii6 • THREE labels: "Fire Alarm Documents" "As Built Permits" "Test and Maintenance Documents" • An adjustable bungee allows you to fit various sizes of binders, �, documents, smoke-cans, etc. • A door bracket holds two CDs, three sets of keys and more documents • A cam lock with two keys BW DocBox2 (11"Wx 15"Hx 4"D) Smaller model without the door bracket. -r I i I ' Don't see the enclosure you need? Other colors,graphic screening, and customization are available Call or e-mail us and we'll be happy to help! for quantities of 25 or more. 1 a I • . \II 1111111.11.1 Indoor & Outdoor Electrical Enclosures I Drive-Alert Vehicle Detection & Asset Protection Systems I Custom Fabrication 800-473-0213 — info@mierproducts.com — www.mierproducts.com ® StarLink Fire MAX 2: SLE-MAX2-Series � The Power of 2: Dual SIM, Dual Path by Napco PdIIih1 •Dual SIM,Dual Path Universal full data 5G LTE-M cellular&/or IP commercial fire alarm reporting from any panel brand,virtually anywhere nationwide •One Model to Stock:Provides both Verizon°&AT&T®Cell Networks plus either sole or IN IRE npi / dual path cell/IP reporting(selectable by plan) RH •Auto-Network-Select by Site-Upon power up,the signal-strength provided by each cell 1. �AT&T + verizOni f a • carrier is analyzed at the site,and the unit will lock-in the best carrier automatically,ie.,AT&T orVerizon.Thereafter,it's periodically reviewed and dynamically swapped when needed. •EZ Cell-Network ID-Red or Blue Indicators-Inside the unit,the Carrier Indicators will light Blue for DUAL SIM/DUA - H — AT&T or Red for Verizon connection(also test button indicates signal strength on each for manual check) AT&T and VERIZON •See/Set SIM Status Remotely-using a PC or smart device,the StarLink Network Operations Center(NOC),in Napco Headquarters,NY,can be accessed allowing you used to set Cell &/or IP UNIVERSAL 5G parameters or view current status,Dual SIM status of accounts •Supports 12V-24V FACUs,No Panel Reprogramming with those that communicate using COMMERCIAL FIRE LTE-M COMMUNICATORS Contact ID and 4/2(such as on legacy panels),as primary or backup. •UL&NFPA Code-compliant,replaces 2 POTs lines per FACU saves thousands of dollars per year over the leased landlines.(Show accounts savings-Free Sales Tool/Calculator App left) AT&T verizonv v NAPCO •Proven StarLink Reliability&Best 5G LTE-M Performance-Works where others can't- Signal Boost'Circuitry&unique dual-diversity twin antennas,maximizing signal acquisition and eliminating the multiphase-effect signal-clash/drop-outs single-antenna units are prone to. •Easiest installation,powered by panel,NO extra power supply,NO extra conduit. (Excludes Metal Direct AC-Powered Model,shown below.) •Labor-Saving Supervision Features Save Time&Money-Uniquely including 4 supervised, programmable EOLR zone inputs;2 Form C Relay outputs(no extra supervision modules to buy 1 ;— ' 4 or install);plus,2 Telephone style jacks for easy FACU-connection.Self-supervised on 4 wires. •Easy-RepeatAccountTemplates-Save your typical account setup and reuse for goof-proof ""• . communicator programming&fast deployment. "•■•••• t •Free StarLink FACU-Saver App-Smartphone Pro sales tool / for calculating/demonstrating account's cellular cost-savings with dealer by number of lines&locations vs.copper POTs lines — leased from phone co.FREE download on Apple Store or Google Play. 1 4 •Pro Incentive Instant Rebate Program-Dealers save on new and retrofit installations, replacing POTs,old radios,sunset networks and even new installations. (Nothing to mail in/fill out;Service credit automatically applied upon valid plan activation. - - See details online;scan QR code on back) •UL&NFPA 72 Fire Code-Compliant,the StarLink Max2 Fire Series Wireless Commercial Fire • ...: Alarm Sole Path&Dual Path Communicators provide universal support for any brand 12Vto .01F-ACIP $LE MAX2 FIRE - • 24Vfire alarm control panel(FACU),reporting in Contact ID and 4/2.With broadest nationwide coverage footprint,Verizon or AT&T,using proven StarLink circuitry,they are also available in locking metal models. Universal Panel-Powered Commercial Fire FACU Communicator: Dual SIM for 2 Networks;Dual Path Cell or Cell/IP all in One Model •Over-the-Air Upgradeable Firmware for updates without a truck-roll. �� verizon 4 AT&T One Dual SIM Dual Path Model is Both Verizon and AT&T and Sole or Dual Path with Cellular+Internet Option.StarLink Fire provides full data reporting,in sole&dual path,as a primary or backup,to any central station of your choice,w/o requiring any special equipment on premises.The units are very easily activated,plans for dual or sole path&check-in periods are selected,and 24/7 account management is provided all through www.napcocomnet.com. mill tire I Easy,Universal Installation at Every Application;standardlyw/Panel-Powered Technology' or metal units with choice of power source.StarLink Fire Communicators are easily connected to any 12Vto 24V panel or Fire Alarm Control Panel(FACU)using easy Quick-Connect FACP modular jacks.For any application,StarLink Max Fire 2 Series comes in standard,ABS plastic Panel-Powered Technology"(powered by the panel),models,or in metal housings w/or w/o&choice of power options,i.e.,direct-connect 120VAC or Plug-in transformer.Quick Tip:Using StarLink Fire Max 2 All as • C. with Power Supply models(suffix-PS)eliminates the need to do recalculations on the fire • system being retrofitted as well. StarLink Fire is End-to-End UL 864 Listed to protect signal reliability,speed&performance dill for critical life and safety alarm reports for maximum life safety&liability protection.UL-Listed 11`••" from the UL 864 StarLink Fire Max 2 communicator,to Napco's NY UL 864 Network Operations Center(shown below in map),to any Central Station's UL Listed Receiver. 4 (It is also backed by Disaster Recovery NOC in PA for immediate,mirrored emergency switchover.) ihriw- SLE-MAX2-CFBPS STARLINK:ALL SIGNALS, .7, , SLE-MAX2-CFB ALWAYS IN THE USA 0 Dual SIM/Dual Path StarLink Fire MAX 2 also available in verizonv+`,... "AT&T Metal enclosures with or without power supply 40, 1•�° StarLlnk� SLE-MAX2 SERIES Fire Dual SIM/Dual Path FIRE f __I.4 Commercial Fire Alarm Cell Communicators tarLink •Dual SIM models auto-select optimal cell carrier- and Red or Blue LED Indicators inside signal -IRE A,..- Verizon or AT&T respectively,shown right. ALP "qm 1 1 \ •LED Status/Trouble Indicators 3 Radio Status LED Indicators 111110r AMP �AT&T + verizon Strength;Amber-Busy/Activation;(visible from outside modelard Red-Trouble.(Additional nal internal LEDs,not visible with cover closed,i.e.,for troubleshooting and for AT&T or Verizon SPECIFICATIONS:(Apply to all models unless otherwise stated) network selection,status).Power LED indicator viewable on outer metal enclosure models. SLE-MAX2-FIRE&SLE-MAX2-CFB: •Sole or Dual Path 5G LTE-M Cell Commercial Fire Alarm Communicator in One-Simply Electrical Ratings for+12V/24V(Models w/o Power Supply) select Cell or Cell/IP Service Plan&check-in period:5 minutes,60 minutes,6 hours or 24 hours. •Input Volta e:10-24VDC regulated(power-limited output from •Signal Boost and Patented Switching Dual Diversity Antenna for maximum signal UL Certified gFACU/panel Aux/Remote Fire Power). acquisition&null/signal-clash avoidance,receiving signals on both antennas •Input Current:24VDC standby:85mA (2 supplied,nothing extra to buy.) SLE-MAX2-CFBPS: •"Return Receipt"Fully-Supervised Communication Path between premise¢ral station, Electrical Ratings for 120VAC,60Hz(Models with Power Supply) keeping channel open until kiss-off is received from Central Station receiver •Input Voltage:120VAC nominal •Input Current:200mA maximum ORDERING INFORMATION •Maximum Charging Current:200mA Dual Sole Dual Low Current Current Electrical Ratings Fire Input 1: Model Description SIM/ Verizon AT&T Path Path Draw, Draw, •Input e:9-25VDC Dual _ Cell Cell/IP Standby Peak P 9 Path (@24V) (@24V) •Max Input Current:Up to 2mAfrom FACU NAC circuit Universal Fire Electrical Ratings for Inputs 2 to 5(Class B): Communicator,Dual SLE-MAX2- •Maximum Loop Voltage:25VDC FIRE SIM,Dual Path,Panel- I i i i i 85mA 325mA Ot •Maximum LoopCurrent:1.2mA(metal models); (plastic) PBS Plastic Housing ) ABSPIasticHousing - -•End of Line Resistor(EOLR)Value:10K Universa Fire Electrical Ratings for PGM3 Output: Communicator,SLE-MAX2 •Open Collector Output:Max Voltage 3Vwhen active;25V max.when not. CFB Dual SIM,Dual ✓ si. si. 17 17 85mA 325mA •PGM Max Sink Current:50mA(up to 15VDC),25mA(15.1 VDC-25VDC) Path,echeoPowered Technology Physical&Environmental . •Plastic Housing:8 x 51/2 x 11/2"(WHD)+antennas(2ea,supplied)81/4"H Universal Fire •Metal Housing:111/2 x 91/2 x 31/2"(WHD)+antennas(2ea,supplied)81/4"H Communicator,Dual SIM,Dual Path,Direct •Housings:2 Keyholes for wall mount SLE-MAX2- ACPower120VAC •Operating Temp.32 to 120°F,93%Humidity Max. CFBPS Metal Housing w/ i l i i l 200mA 200mA Provision.For Plug-in COMPLIANCES: TRF12 XFormer,16VAC, NFPA 72 Eds:2022,2019,2016,2013,2010;UL 2610,UL 985,UL1023,UL864 10th Ed.,CSFM, 20VA(w/provision for backup battery) NYC FD,LAFD Napco US Network Operations Center(NOC)UL 86410th Ed.,UL 1610,UL 1635 OPTIONS/ACCESSORIES: ill SLE-WIFI-MODULE:Optionally connects supported dual path models to Internet via WiFi, eliminating Ethernet cable connection.Requires 7AH battery.(see WI2191) Oa SLE-ANTEXT30:StarLink Omni-X Optional Extended Range Marine-Grade Complete Antenna Kit,w/30'of ultra low-noise LMR 300 cable,all hardware&ground fault isolator plate. \:, II 1 I SLE-ANTEXT50:as above,50'cable SLE-ANTEXT75:as above,75'cable SLE-ANTEXT100:as above,100'cable SLE-ANTEXT04:as above,4'cable SLE-FIRE-VR:FACU Voltage Drop Kit,maintains safe input voltage<27.5VDC 1 TRF12:Plug in AC Transformer,used w/SLE-MAX2-CFBPS model,16.5V/20VA :1 1 I■ (use subject to local code). AN GEM-TAMPERKIT:Tamper switches and screws to protect metal housing where required. SLE-ULPS-R:Power Supply,for installations where FACU cannot provide Aux Power. SLE-FMBB:Opt.Metal Cable Management Backboxforsurface mounting plastic StarLink • . communicator models adjacent to FACUs on same plane.Radio easily snaps in on 4 stand-offs, no rewiring.Red metal enclosure w/3/4"cable knockouts;2 Connectors&4"Conduit,supplied. AT&T Coming soon Also See FireLink FACUs with built-in Starlink Communicators&LCD Touchpads for Canada on Door addressable&conventional cloud-.ro•rammable. w .StarLinkFire.com r ww Addressable, Conventional Fire Alarm Systems & o,.; o I - Leading Commercial Fire Cellular Communications ;- ' - g I For Compliance,Always Consult with AEU&TechDocsby Model,i.e.,SLE-MAX2-FIRE(Plastic)W12609LF;SLE-MAX2-CFBPS,-CFB(Dual Path Metal) ❑• W12642LE Starb nk&StarLinkMAX Fire are trademarks of NAPCO Security Technologies,Inc.Other marks remain intellectual property of their FOR MORE • respective companies.Preliminary data&promotions subject to change without notice.©NAPCO2024.1 A852 =_ . DF-61010:C SD365 Series ezij Flre trreALarms Addressable Photoelectric Smoke Detectors by Honeywell Addressable Devices The Fire•Lite® Alarms SD365(A), SD365R(A), and SD365HT(A) intelligent plug-in smoke detectors are designed for both perfor- mance and aesthetics, and are direct replacements for the SD355 Series. A new modern, sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more strin- gent code standards. Exclusively for use with Fire•Lite's addressable fire alarm control panels, the SD365(A) Series point ID capability allows each detec- tor's address to be set with rotary,decimal address switches,provid- ing exact detector location for emergency personnel to quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local,visible sensor indication. The SD365(A) Series also offers 135°F (57°C) fixed temperature thermal sensing on the SD365T(A)and a remote test capable detec- tor on the SD365R(A) for use with DNR(A)/DNRW duct smoke detector housings. Features • Plugs into separate base for ease of installation and maintenance SLC LOOP: • Separate base allows interchange of photoelectric, ionization and • Two-wire SLC loop connection thermal sensors • Unit uses base for wiring OPTIONS: • Compatible with LiteSpeedTM and CLIP protocol systems • Optional relay, isolator,and sounder bases • Stable communication technique with noise immunity Installation ADDRESSING: SD365 Series plug-in intelligent smoke detectors use a detachable • Addressable by device base to simplify installation, service and maintenance. Installation • Rotary,decimal addressing instructions are shipped with each detector. (Refer to the Fire•Lite panel manuals for device capacity.) Mount detector base(all base types)on an electrical backbox which ARCHITECTURE: is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DF-60059. • Sleek, low-profile, stylish design Unique single source design to respond quickly and dependably NOTE: Because of the inherent supervision provided by the SLC loop, • end-of-line resistors are not required. Wiring "T-taps"or branches are to a broad range of fires permitted for Class"B"wiring only. • Integral communications and built-in device-type identification When using relay or sounder bases, consult the 1300(A) installation • Built-in tamper resistant feature sheet 156-3626 for device limitations between isolator modules and isola- tor bases. • Remote test feature from the panel • Walk test with address display (an address on 121 will blink the Construction detector LED: 12-[pause]-1(LiteSpeed systems only) These detectors are constructed of fire-resistant plastic.The SD365 • Built-in functional test switch activated by external magnet Series plug-in intelligent smoke detectors are designed to commer- • Removable cover and insect-resistant screen for simple field cial standards and offer an attractive appearance. cleaning • Expanded color options Operation OPERATION: Each SD365 Series detector uses one of the panel's addresses (total limit is panel dependent)on the Fire•Lite Signaling Line Circuit • Designed to meet UL 268 7th Edition (SLC). It responds to regular polls from the control panel and reports • Factory preset at 1.5%nominal sensitivity for panel alarm thresh- its type and the status. If it receives a test command from the panel old level (or a local magnet test), it stimulates its electronics and reports an • LED "blinks"when the unit is polled (communicating with the fire alarm. It blinks its LEDs when polled and turns the LEDs on when panel)and latches in alarm. commanded by the panel. The SD365 Series offers features and Low standby current performance that represent the latest in smoke detector technology. •MECHANICALS: Detector Sensitivity Test • Sealed against back pressure Each detector can have its sensitivity tested (required per NFPA 72, • SEMS screws for wiring of the separate base Chapter 14 on Inspection, Testing and Maintenance)when installed/ Designed for direct surface or electrical box mounting connected to an Fire•Lite addressable fire alarm control panel. The • results of the sensitivity test can be printed for record keeping. DF-61010:C•5/28/2020—Page 1 of 3 Product Line Information B200SA-WH: Same as B200S-WH, ULC listing NOTE:"-IV"suffix indicates CLIP and LiteSpeed device. B200SA-IV: Same as B200S-IV, ULC listing NOTE:"A"suffix indicates Canadian version. B200SCOA-WH: White, Intelligent, programmable sounder base in SD365:White, low-profile intelligent photoelectric sensor, LiteSpeed English/French (required in Canada for ULC applications with CO only Series detector applications SD365A: Same as SD365 but with ULC listing B200SCOA-IV: Ivory Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO SD365-IV: Ivory, low-profile intelligent photoelectric sensor Series detector applications, ULC listing SD365A-IV: Same as SD365-IV but with ULC listing B200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- SD365T:White,same as SD365 but includes a built-in 135°F(57°C) 10% with a square wave or its equivalent; designed to meet the fixed-temperature thermal device, LiteSpeed only NFPA 72 sleeping space requirement. (CSFM:7300-1653:0238) SD365TA: Same as SD365T but with ULC listing B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable SD365T-IV: Ivory, same as SD365T but includes a built-in 135°F sounder base. Produces a fundamental frequency of 520 Hz +/- (57°C)fixed temperature thermal device 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM:7300-1653:0238) SD365TA-IV: Same as SD365T IV but with ULC listing B200SR-WH: White, Intelligent sounder base capable of producing SD365R: White, low-profile intelligent photoelectric sensor, remote sound output with ANSI Temporal 3 or continuous tone. Intended for test capable,for use with DNR/DNRW, LiteSpeed only retrofit applications. (CSFM:7300-1653:0213) SD365RA: Same as SD365R but with ULC listing, for use with B200SR-IV: Ivory, Intelligent sounder base capable of producing DNRA sound output with ANSI Temporal 3 or continuous tone. Intended for SD365R-IV: Ivory,low-profile intelligent photoelectric sensor,remote retrofit applications. (CSFM:7300-1653:0213) test capable,for use with DNR/DNRW B200SRA-WH:Same as B200SR-WH with, ULC listing SD365RA-IV: Same as SD365R-IV but with ULC listing,for use with B200SRA-IV: Same as B200SR-IV in Ivory color, ULC listing DNRA B200SR-LF-WH: White, Low Frequency Intelligent, programmable INTELLIGENT BASES sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NOTE:For details on intelligent bases,see DF-60059. NFPA 72 sleeping space requirement. Intended for retrofit applica- B300-6:White, 6"base,standard flanged low-profile mounting base tions. (CSFM:7300-1653:0238) (CSFM:7300-1653:0109) B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable B300-6-IV: Ivory,6" base, standard flanged low-profile mounting sounder base. Produces a fundamental frequency of 520 Hz +/- base (CSFM: 7300-1653:0109) 10% with a square wave or its equivalent; designed to meet the B300A 6: Same as B300 6, ULC listed NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM:7300-1653:0238) B300A-6-IV: Ivory, 6" standard flanged low-profile mounting base,ULC listed MOUNTING KITS AND ACCESSORIES B300-6-BP: Bulk pack of B300-6, package contains 10 TR300:White, replacement flange for B210LP(A) base B501-WHITE: White, 4" standard European flangeless mounting TR300-IV: Ivory, replacement flange for B210LP(A)base base. UL/ULC listed (CSFM: 7300-1653:0109) RA100Z(A): Remote LED annunciator. 3-32 VDC. Mounts to a U.S. B501-BL: Black, 4" standard European flangeless mounting base. single gang electrical box. For use with 6501(A)and 6300 6(A). UUULC listed (CSFM:7300-1653:0109) M02-04-00:Test magnet B501-IV: Ivory color, 4" standard European flangeless mounting M02-09-00:Test magnet with telescoping handle base. UL/ULC listed (CSFM: 7300-1653:0109) CK300:Color Kit(includes cover and trim ring),white, 10-pack B501-WHITE-BP: Bulk pack of B501-WHITE contains 10 CK300-IV: Color Kit(includes cover and trim ring), ivory, 10-pack B224RB-WH:White, relay base(CSFM: 7300-1653:0216) CK300-BL:Color Kit(includes cover and trim ring), black, 10-pack B224RB-IV: Ivory, relay base(CSFM:7300-1653:0216) B224RBA-WH:White, relay base, ULC listing B224RBA-IV: Ivory, relay base, ULC listing B224BI-WH:White, isolator detector base(CSFM:7300-1653:0216) B224B1-IV: Ivory isolator detector base(CSFM:7300-1653:0216) B224BIA-WH:White, isolator detector base, ULC listing B224BIA-IV: Ivory isolator detector base, ULC listing B200S-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4,continuous tone,marching tone,and custom tone. Uses LiteSpeed protocol. (CSFM:7300-1653:0213) B200S-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4,continuous tone,marching tone,and custom tone. Uses LiteSpeed protocol. (CSFM: 7300-1653:0213) Page 2 of 3—DF-61010:C•5/28/2020 SYSTEM SPECIFICATIONS Sensitivity: Listings and Approvals • UL Applications:0.5%to 4.0%per foot obscuration. Listings and approvals below apply to the SD365 Series detectors. • ULC Applications: 0.5%to 3.5%per foot obscuration In some cases, certain modules may not be listed by certain Size:2.0" (51 mm)high; base determines diameter approval agencies, or listing may be in process. Consult factory for —B300-6: 6.1" (15.6 cm)diameter latest listing status. • —B501:4" (10.2 cm)diameter UL/ULC Listing: S1059 • For a complete list of detector bases see DF-60983 FM Approved • CSFM:7272-0075:0502 Shipping weight:3.4 oz. (95 g) Operating temperature range: • SD365:32°F to 122°F(0°C to 50°C) • SD365T Series:32°F to 100°F(0°C to 38°C) • SD365R Series installed in a DNR/DNRW, -4°F to 158°F (-20°C to 70°C) UL IULC Listed Velocity Range: 0-4000 ft/min. (1219.2 m/min.), suitable for installation in ducts Relative humidity: 10%—93%non-condensing Thermal ratings:fixed-temperature set point 135°F(57°C), rate-of- rise detection 15°F(8.3°C)per minute, high temperature heat 190°F (88°C) ELECTRICAL SPECIFICATIONS Voltage range: 15-32 volts DC peak Standby current(max.avg.):200pA @ 24 VDC(o ne communica- tion every 5 seconds with LED enabled) Max current:4.5 mA @ 24 VDC("ON") DETECTOR SPACING AND APPLICATIONS Fire•Lite recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors 30 feet (9.1 m). For specific information regarding detector spacing, placement, and special applications refer to NFPA 72. A System Smoke Detector Application Guide, document SPAG91, is available at www.systemsensor.com. LiteSpeedTM is a trademark, and Fire•Lite® Alarms and System Sensor® are registered trademarks of Honeywell International Inc. ©2020 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. ENGINEERING 8 MANUFACTURING QUALITY SYSTEMS For more information,contact Fire•Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. Country of Origin:Mexico www.firelite.com Page 3 of 3—DF-61010:C•5/28/2020 DF-52013:D•E-100 BG-12LX �J Flre•LrreALarms Addressable Manual Pull Station by Honeywell Addressable Devices General The Fire•Lite BG-12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface (mounted inside) for Fire•Lite's addressable fire alarm control panels (FACPs) FIRE Because the BG-12LX is addressable, the control panel can display the exact location of the activated manual station.This leads fire personnel quickly to the location of the alarm. Features PUSH IN • Maintenance personnel can open station for inspection and PULL DOWN address setting without causing an alarm condition. • Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. • Handle latches in down position and the word"ACTIVATED" appears to clearly indicate the station has been operated. • Captive screw terminals wire-ready for easy connection to ®FfreuTe®,4larms SLC loop(accepts up to 12 AWG/3.25 mm2 wire). by Honeywell I • Can be surface mounted (with SB-10 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single- G gang, double-gang,or 4" (10.16 cm)square electrical box. • Smooth dual-action design. a • Meets ADAAG controls and operating mechanisms guide- LL lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. • Highly visible. usually needed for semi-flush mounting with 4" (10.16 cm) or • Attractive shape and textured finish. double-gang boxes(not with single-gang boxes). • Key reset. Operation • Includes Braille text on station handle. • Optional trim ring(BG12TR). Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTI- • Meets UL 38, Standard for Manually Actuated Signaling VATED" (in bright yellow) appears at the top of the handle, Boxes. while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the Construction key and pull the door open.This action resets the handle;clos- Shell, door, and handle are molded of durable polycarbonate ing the door automatically resets the switch. material with a textured finish. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual Specifications switch.Two rotary decimal switches allow address settings (1 —159 with Breakaway Tab removed for MS-9600 Series, 1 — • Shipping Weight:9.6 oz. (272.15 g) 99 and MS-9200UDLS, 1 —50 for MS-9050UD). • Normal operating voltage:24 VDC. • Maximum SLC loop voltage:28.0 VDC. Architectural/Engineering • Maximum SLC standby current: 375 pA. Specifications • Maximum SLC alarm current:5 mA. Manual Fire Alarm Stations shall be non-coded, with a key- • Temperature Range: 32°F to 120°F(0°C to 49°C) operated reset lock in order that they may be tested, and so • Relative Humidity: 10%to 93%(noncondensing) designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key.An operated sta- • For use indoors in a dry location tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of Installation red-colored polycarbonate material with clearly visible operat- The BG-12LX will mount semi-flush into a single-gang,double- appear instructions provided on the cover. The word FIRE shall gang,or standard 4"(10.16 cm)square electrical outlet box,or appear on the front of the stations in white letters, 1.00 inches will surface mount to the model SB-10 or SB-I/O surface back- (2.54 cm) or larger. Stations shall be suitable for surface box. If the BG-12LX is being semi flush mounted, then the mounting on matching backbox SB-10 or SB-I/O;or semi-flush optional trim ring (BG12TR) may be used. The BG12TR is mounting on a standard single gang, double gang, or 4"(10.16 cm) square electrical box, and shall be installed DF-52013:D•4/13/2012—Page 1 of 2 within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel,send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. Product Line Information BG-12LX: Dual-action addressable pull station. Includes key locking feature. (Listed for Canadian and non-Canadian appli- cations.) SB-10: Surface backbox; metal. SB-I/O: Surface backbox;plastic. BG12TR: Optional trim ring. 17003: Keys,set of two. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. • UL/ULC Listed: S711 (listed for Canadian and non-Cana- dian applications). • MEA: 67-02-E. • CSFM:7150-0075:0184. • FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. FireLite®Alarms®is a registered trademark of Honeywell International Inc. ©2012 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING&MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Fire•Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. www.firelite.com Page 2 of 2—DF-52013:D•4/13/2012