Loading...
PFI2020-00092 CITY OF TIGARD PUBLIC FACILITIES IMPROVEMENT PERMIT COMMUNITY DEVELOPMENT Permit#: PF12020-00092 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421 Date Issued: 03/19/2020 Parcel: SEG1586 Jurisdiction: Tigard Site address: Subdivision: Lot: Project: Centuryl-ink National Project Description: SEG 1586/7500 SW Tech Center Drive. Dig and intercept existing conduit on south side of SW Tech Center Drive, in sidewalk in front of 7500 building. Place new 2'x 3'handhole at interception point. Class of Work: FEES Type 1 -Utilities(gas, electric, data) Description Date Amount PFI Permit Fee 03/17/2020 $300.00 Total $300.00 Owner: REQUIRED INSPECTIONS Call 503-639-4175 for the IVR inspection request line or visit the City of PHONE: Tigard website at www.tigard-or.pov to schedule inspections online. Contractor: NORTH SKY COMMUNICATIONS LLC 0 11818 SE MILL PLAIN BLVD SUITE 410 VANCOUVER, OR 98684 PHONE: 3602546920 Applicant: TODD HURD 214 E 24TH STREET VANCOUVER, WA 98663 PHONE: 5034676422 Please sign below to indicate acceptance of conditions and return a copy with the proposed work schedule along with names and contact information of responsible parties before beginning work. Permittee/Applicant Signature: Issued By: Special Conditions(See Attached) Note:THIS PERMIT DOES NOT COVER WORK ON PRIVATE PROPERTY Conditions for PF12020-00092 Type: Condition Name: Status: Severity: PFI_Utilities 01 -WORK SITE REQUIREMENTS Applied Notice Applicant must comply with all applicable provisions of federal and state law,the Tigard Municipal Code, and the terms of any agreement with the City of Tigard regarding work to be done pursuant to this permit. PFI_Utilities 02-WORK SITE AREA Applied Notice The work area and approach roads shall be maintained in a clean condition,free from obstructions and hazards. The spreading of mud or debris or storage of materials or equipment of any kind upon any public roadway is strictly prohibited and violation shall be cause for immediate cancellation of the permit. The City may at any time order immediate clean-up and suspension of work to accomplish clean-up. PFI_Utilities 03-WORK SITE EROSION CONTROL Applied Notice Prior to starting work, effective and approved erosion control devices must be installed and maintained meeting the Clean Water Services and DEQ requirements. The City may at any time order corrective action and suspension of work to accomplish effective erosion control. PFI_Utilities 04-WORK SITE REPAIRS Applied Notice Disturbed landscaped areas shall be restored or replaced. Existing signs, pavement markings, mailboxes, etc. shall be reinstalled or replaced,with like kind of material. Obtain City approval of restoration work. PFI_Utilities 05-TRAFFIC CONTROL SPECIFICATIONS Applied Notice Applicant shall provide traffic control according to the current edition of the"Manual on Uniform Traffic Control Devices [MUTCD]for Streets and Highways", U.S. Dept. of Transportation, FHWA, current edition,American Traffic Safety Services Association [ATSSA], and Oregon Temporary Traffic Control Handbook [OTTCH]. PFI_Utilities 06-TRAFFIC CONTROL PLAN Applied Notice Submit a job specific traffic control plan. A copy of the approved traffic control plan shall be readily available at the work area. Traffic control devices,flag persons, etc., shall be in place prior to initiation of construction work and shall be effectively maintained. PFI_Utilities 07-TRAFFIC CONTROL ROAD CLOSURE Applied Notice Public roadway shall not be closed to traffic, at any time,without obtaining written approval from the City Engineer. The applicant is responsible to provide 48 hour advance notice of traffic flow disruptions to affected businesses, residents and area wide Emergency Services: 503-629-0111 (Tigard Police Dept.,Tualatin Fire&Rescue)and to 503-962-8140 (Tri-Met) and 503-431-2345(Tigard School District)and other service providers impacted by such closure. PFI_Utilities 08-TRAFFIC CONTROL ADVANCE WARNING Applied Notice Advance warning of traffic disruption shall be provided to the public by placement of an approved advance notification sign at each end of the construction area 72 hours(min.)before initiation of construction work. PFI_Utilities 09-TRAFFIC CONTROL PROPERTY ACCESS Applied Notice Access to existing properties shall be maintained at all times, including normal delivery service and mail service.Obtain City approval of any access closures. PFI_Utilities 10-TRAFFIC CONTROL WORK HOURS Applied Notice Work is permitted in daylight between the hours of 7:00 a.m. to 7:00 p.m. Mon-Fri unless otherwise authorized by the City. PFI_Utilities 11 -TRAFFIC CONTROL LIMITED WORK HOURS Applied Notice Hours of construction work on collector and arterial roads will be limited to 9:00 a.m.to 3:00 p.m. unless authorized by the City Engineer. Work will not be permitted on collector and arterial roads between 3:00 p.m.to 9:00 a.m. unless authorized by the City Engineer. PFI_Utilities 12-TRAFFIC CONTROL MODIFICATION Applied Notice The City reserves the right to add to or modify traffic control requirements as necessary to effectively control traffic and to assure public safety. PFI_Utilities 13-DRAINAGE CONTROL Applied Notice Drainage shall be controlled within the work site and shall not adversely affect adjacent private property, public property and the receiving system. The City may at any time order corrective action and suspension of work to accomplish effective drainage control. PFI_Utilities 14-UTILITY NOTIFICATION Applied Notice Oregon law requires following the rules adopted by the Oregon Utility Notification Center. Said rules are set forth in OAR 952-001-0100 through OAR 952-001-0080. Copies of said rules may be obtained from the Center by calling 503-246-1987. If you have any question about the rules,contact the Center. NOTE: Damage to utilities shall be corrected at the permit holder's expense. PFI_Utilities 15-UTILITY LOCATION CONFLICT Applied Notice Applicant must verify all existing utilities for both vertical elevation and horizontal location prior to start of work(pothole before digging if necessary). Should conflicts arise and redesign or relocation of facilities be necessary, it shall be done at the applicant's expense. Changes must be approved by the City in advance of work.Applicant shall coordinate the work with affected utility agencies. PFI_Utilities 16-TEMPORARY PATCH Applied Notice A temporary hard-surface patch shall be placed on trenches within roadways at the end of each work shift. Obtain advance approval of patching method. No trench shall be left at any time in an un-safe condition. Applicant is responsible for and is liable for hazards or damage resulting from the prosecution of the work. PFI_Utilities 17 -REPAIR OF EXISTING FACILITIES Applied Notice Work under this permit shall include repair of existing facilities(roads,ditches,etc.)as may be necessary, as determined by the Inspector,to overcome deterioration or damage which occurred in conjunction with the work authorized by the permit. Corrective work shall be done at the applicant's expense. PFI_Utilities 19-PRECONSTRUCTION MEETING Applied Notice Before initiating any construction activity,the applicant shall coordinate with the City's inspector,Trent Brickey at 503-718-2686,to establish a preconstruction meeting. PFI_Utilities 20-NOTICE TO COMMENCE WORK Applied Notice The applicant shall notify the City's Inspector twenty-four(24)hours prior to commencing work,prior to any staged inspection,and after completing work covered by the permit. PFI_Utilities 21 -PERMIT/PLAN ON SITE Applied Notice A copy of the permit including a Certificate of Insurance,and all attachments, and a copy of the approved construction plan and all amendments shall be readily available at the work area. All work shall conform to the permit terms,conditions and provisions and to the City approved permit plans, and approved plan amendments and to the City's standards and specifications and to these General Conditions. Changes to any of these must be approved by the City, in advance of work performance. PFI_Utilities 22-DAILY INSPECTION REPORTS Applied Notice Applicant shall submit daily inspection reports,on a weekly basis,to the City's Inspector. PFI_Utilities 23-MONUMENT PROTECTION Applied Notice Existing monuments, property comers, and survey markers shall be protected. Replacement shall be at the permit holder's expense. PFI_Utilities 24-VALIDATION OF MATERIAL/CONSTRUCTION Applied Notice The City's Inspector may,at his discretion, require tests and or reports from the applicant to validate claims of material or construction adequacy/compliance. Such tests/reports shall be provided at the applicant's expense. PFI_Utilities 25-EMERGENCY CONTACTS Applied Notice Provide to the City inspector, in writing,the names and 24 hour emergency telephone number of two(2)persons who have authority to resolve problems,take corrective action and, in general,will be responsible in case of any emergency. The applicant shall notify the City Inspector, in writing,of any/all assignment changes. PFI_Utilities 26-RIGHT OF ENTRY/EASEMENTS Applied Notice Applicant to obtain proper right-of-entry and/or easements prior to starting work. Proof of right-of-entry or properly executed easements,shall be provided to the City. The City shall in no way be construed to be liable for the applicant's failure to obtain or provide for proof of right-of-entry or easements. PFI_Utilities 27 -PRIVATE PROPERTY AGREEMENTS Applied Notice Provide the City a copy of an executed agreement[s]from the owner for each private property disturbed by construction activity. PFI Utilities 28 -AS-BUILT DRAWING Applied Notice 1,2,3,4,5 28-AS-BUILT DRAWING One as-built drawing showing all new public improvements, including any revision made to the previously approved construction plans and, also, any improvement which may impact an existing public system or facility, shall be provided to the City by a registered civil engineer along with an engineer's certification of installation compliance(Certificate of Compliance). 1,2,3,4,5 28-AS-BUILT DRAWING One as-built drawing showing all new public improvements, including any revision made to the previously approved construction plans and, also, any improvement which may impact an existing public system or facility, shall be provided to the City by a registered civil engineer along with an engineer's certification of installation compliance(Certificate of Compliance). One as-built drawing showing all new public improvements, including any revision made to the previously approved construction plans and, also, any improvement which may impact an existing public system or facility, shall be provided to the City by a registered civil engineer along with an engineer's certification of installation compliance (Certificate of Compliance). PFI—Utilities 31 -OTHER Applied Notice Other RECEIVED City of Tigard MAR 112020 PFI #: 202-0-0009 2— ENGINEERING DEPARTMENT CITY OF TIGARD ANNING/ENGINEERING 9% Public Facilities �`mprovement (PFI) Permit PROJECT INFORMATION TYPE OF WORK Project name: 7500 TECH CENTER I 8 TYPE 1—Franchise Utility Work Brief description of project: DIG &INTERCEPT EXISTING CONDUIT ON performed by NWN,PGE, or utility agency SOUTH SIDE OF SW TECH CENTER DR, IN SIDEWALK IN FRONT OF ❑ TYPE 2—ROW Sidewalk/Driveway/Sewer 7500 BLDG. PLACE NEW 2'X3' HANDHOLE AT INTERCEPTION POINT. Work performed for the purpose of: • Sidewalk installation or repair • Driveway approach installation and repair SITE INFORMATION • Sanitary sewer lateral installation and Location (address if available): 7500 SW TECH CENTER DR main line tap ❑ TYPE 3—Full Scale Development Work G I Cj8(� Tigard, OR 97223 performed with land use approval which includes any of the following: • Subdivisions or Partitions APPLICANT INFORMATION • Streetaridening Name: Centuryl-ink National • Mainline installation for sanitary sewer, storm sewer, Tigard water, and Tigard Mailing address: 214 E 24th St water service area City/state: Vancouver, WA Zip: 98663 ❑ TYPE 4—Small Cell Technology Phone: 503-467-6422 ❑ TYPE s-Tigard Triangle Email: Todd.Hurd@CenturyLink.com Phone: 503-467-6422 NOTE: Type 1 and 2 applications may be Contact name: Todd Hurd emailed to mwmrmits6&,igard-or. ovv. Phone: 503-467-6422 Email• Todd.Hurd@CenturyLink.com CONTRACTOR INFORMATION ❑ Same as applicant Name: North Sky Communications, Inc CCB Number: 208747 Mailing address: 10860 SW Clutter Rd City/State: Sherwood, OR Zip: 97140 Phone: (503) 949-8195 (Brandon Stavang) Email: bstavang@northskycomm.com ENGINEER INFORMATION Name: Waeco Engineering Mailing address: 18543 Cascade View Dr SE City/State: Monroe, WA Zip: 98272 Phone: 360-722-2852 Email: spencer@waecoeng.com ADDITIONAL INFORMATION Estimated value of work is required(if over$5,000):$ (within the public right-of-wap) Is work related to a LAND USE DECISION? ❑Yes 0 No Case number: City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www..tigard-or.gov • 503-718-2421 • Page I of 4 APPLICANTS NOTE: Person specified as 'Applicant" shall be designated"Permittee"and shall provide financial assurance for work,if required by the city pursuant to TMC 15.04.140. * With the exception of a utility operating pursuant to a valid franchise or license with the City of Tigard,when the owner and the applicant are different people,the applicant must be the purchaser of record or a lessee in possession with written authorization from the owner or an agent of the owner. The owner must sign this application in the space provided or submit a written authorization with this application. Franchised or Licensed Utilities are not required to obtain the owner's signature on the application. I, the applicant, certify that: • To the best of my knowledge,all the information provided within this application package is complete and accurate. • The above request does not violate any recorded deed restrictions that may be attached to or imposed upon the subject property. • If the application is granted,I will exercise the rights granted in accordance with the terms and subject to all the conditions and limitations of the approval. Spencer Kariniemi(signed for Todd Hurd) 3/11/2020 Applicant's or authorized agent's signature Print name Date Property owner's signature (if required) Print name Date STAFF USE ONLY 1 Case No: f r t2DIO"0 --7 Permit fee: 5 00,420 Received by: A- Date: Approved by: 7t-Wl � Date: .3�t��Z' Notified by: A-L.- Date:3 City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 0 www..tiprd-or.gov • 503-718-2421 • Pdge 2 of 4 DEVELOPMENT ENGINEERING FEES Public Facility Improvement(PFI)Permit: INITIAL PFI PERMIT FEE Part 1: Required submittal fee is 10%of the Net PFI Permit Fee.See below for calculations.Minimum of$300. NET PFI PERMIT FEE Part 2: All non-water system improvements engineer's estimate X 7%(less the initial PFI Permit Fee). WATER LINE CONSTRUCTION FEE Part 3: All public water system improvements engineer's estimate X 12%. FOR ONLY • ONLY TYPE 4: SMALL WIRELESS CHECKLIST REQUIREMENTS Does applicant have a right-of-way license? ❑Yes ❑No TYPE 1 AND TYPE 2-Must include a sketch showing: Under the wireless facilities standards,is the proposal B Dimensions considered?(check all that apply): ❑Small Cell ❑Irlacro 8 Street Name How many install sites are proposed as part of this permit 8 Site Address application? TYPE 3-Must provide 4 sets of plans (sized 24 x 36 or 22 x 34) and an electronic version of all submittal The proposed equipment is located on which of the following: items. The plans must that include: ❑Public Right-of-Way ❑Private Property ❑ Cover—Site,Vicinity,Abbreviation,Legend If equipment is to be located on private property,describe the ❑ General Notes(City,Water,Server,etc.) type&use: ❑ Street(Plan,Profile) ❑ Water,Storm and Sanitary(Plan Profile) ❑ Water Quality Facilities ❑ Grading ❑ Landscaping/Tree Plan ❑ Composite Utility Plan(Electrical,Phone,Gas, Storm, Sanitary,Water,Signage,Street Lights,etc.) ❑ Details ❑ Traffic Sight Distance ❑ Signing and Striping ❑ Street Light Plan and Photometric ❑ Engineers seal/signature ❑ Sheet label(project land use name,revision and plan log block,dates and sheet numbers.) ❑ Engineers Construction Estimate Additional Submittals (per land use conditions,if applicable) ❑ Traffic Report ❑ Storm water Drainage Calculations ❑ Geotechnical Report ❑ Preliminary Access Report(Sight Distance) ❑ Proposed Plat ❑ Pathway Design ❑ Water Provider Approval Cityof Tigard 13125 SW Hall Blvd. Tigard,Oregon 97223 • www.tigard-or.gov • 503-718-2421 • Page 3 of 4 4 sw "y " jEdge of Pavement I 4— Ditch ---- Streetlight I —•—•—•—•—•—•—•—f'—•— l ° F/eai Drein t o � I iT—propos elwere" v N{ Existing House Existing j Driveway oI aI C ;i I j o l � Existing Shop j • � J � I Powerpole fir, 'o 0 I l a 95, I o groper Lme—-—-—-—-—- Fire Hydrant(FH) � � I l Scale: 'I"=30' � I I TYPE 1 AND TYPE 2: MINIUM SKETCH REQtJIREMENTS (Put N/A if not i ! � � I applicable) X North arrow X Property lines&dimensions X Existing utilities locations (sewer, storm,water) X Street& street names X All existing structures X Proposed work X Existing curb or edge of pavement X Utility&street light poles X Existing S/W or D/W apron NSA Slope of property NIA Trees City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • wwwtigard-oxgov • 503-718-2421 • Page 4 of 4 Page 106 2011 Edition Diversion into a Continuous Left Turn Lane Diagram 430 Diagram 430 shows work in the travel lane(s) next to a continuous two-way left turn lane with one direction of traffic diverted into the continuous two-way left turn lane. 1. Use truck-mounted flashing warning lights on work and protection vehicles. See Section 4.3—Lights and Lighted Signs for exceptions. 2. For added visibility, a truck-mounted arrow board or PCMS in caution mode may be used. 3. When two or more travel lanes are reduced to a single lane before the diversion, each lane shall be closed separately. Layout traffic control according to ODOT Standard Drawing TM 852 for 5-lane sections. 4. A shifting taper(L/2) may be added in the diverted traffic direction across the continuous two-way left turn lane (as shown). This option is recommended when the speed is 45 mph or greater. Sign Spacing and Buffer Lengths(feet) Pasted Spa dna Between Signs "Buffer" Speed A B C Spam 20 so 25 100 100 100 75 30 100 40 350 350 350 150 4S 180 50 S00 S00 S00 210 55 250 60 285 65 700 700 700 325 70 365 Chapter 5 September 2016 2011 Edition Page 107 Diversion into a Continuous Left Turn Lane Diagram 430 ROAD WORK AHEAD l B lylt CENTER .*. LANE CLOSED AHEAD A II Buffer � I :I 1 Protection Vehicle w/TMA(both Optional) See Chapter 4 Buffer • L/2 i ' L/2 I • I A 1 7 t B ROAD V -. r: AHEADWORK September 2016 Chapter 5 CONTACTS TODD HURD CENTURYLINK NATIONAL TODD HURDOCENTURYLINK.COM ADDRESS: 7500 SW TECH CENTER DR, PORTLAND, OR 97223 SOS OSTK SPONGER ARINIEMI PROJECT MANAGER PROJECT NAME: 7500 TECH CENTER WAECGENGINECO SP NC�c2^�gWAECOENGCOM ( , � B5� SITE INDEX IQ I-COVER SHEETISITE LOCATION 2-LEGEND S-DESIGN VIEW 1 d-TY I LS _ ♦ 5•SITE PHOTOGRAPHS SW CHFRRY DR ~� M N1 R•N SW SANDBURG SUT SCOPE OF WORK: j' 1• STARTING ON THE SOU01 SIDE OF SW TECH CENTER DR NEAR 7500 SW TECH CENTER DR, A INTERCEPT EMSTING TW TELECOM DUCT • �,a. BANK"ERE AND TURNS EAST INTERCEPT RECO TOORESSµB SECTIOON NEW OF AFFFEECTED E. 4$iETiIR;f El „r 'T SIDEWALK TO CITY OF TIGARD STANDARDS IF I: SW TECH CENTER DR SHEET3 qV� Itl - • 1fi SITE LOCATION MN#lT RNOJM,I III LN 0t T1Y ON�ML ra GEtE oRrtEN cauleJJr xm..lur.belaw. p ��T�• Call x1m�.yo�ee. LMI(3}'.Fa.�w CenturyLink- f CENTVRnNK ENGNEW TOW HUM 1T]f ENGINEERING FIRM:WHEW ENGINEERING PROJECT NUMBER..F%M LWATON:]5[09W TECHCENIEAOR, PORTLANO.OR B1]3] )RAWING NAME 1 ,M G,Nw p adYN TfAWgZx p5aA5[ CONFIGENTNIIPRO RIETFAY I LEGEND LINETYPE ® RISER VAULT- VAULT-D SfNG POLE NO A POLE ATTACHMENT CALLOIUT-DOSING --B---B---B-- W r1OLR-DvwV UIINn O-0 USE DYHYWC PULL DOWN TO SEEM -13---B---B—— UG FIBER-PROPOSED Mtat»DIE V LT IS FROM I TO 6 ATTAMN A ABORAL FIBER-EXSTING © POWER VAULTOAT�ETt -A AERIAL FIBER-PROPOSED p CATCH BAST INET pVAULT- VAULT-PROPOSED POLE NO N A POLE ATEADWENr CALLOUT-PROPOSED STRAND-0fSTM n VAULT UTRITYI 0-0 USE DYNAMIC PULL DOWN TO SEEM STRAND-PROPOSED , FRE.HYDRANT LEVEL O FROM 1 NI 8 ATTADILO05 .-�--� CONDUIT-PROPOSED -{U• GRWND/BOND O O CABLE FEARS.MER:LOERS C1BLE SPAN OV.LOIIT-EXSINC \ / AERIAL STORAGE-EX19NG CABLE OWNEA:IE%F FOR USE ON PAPER SPACE(SHOWN AT 50X) INNERDUCT-EXISTING J''S_ STREET LIGHT 0 �LL LSH: 'IH 'I INNEIOUCT-PROPOSED M pNOTES: GAS pQ AERAL STORAGE- PROPOSED O CABLE PMT@ MERS CABLE SPIN GAPERS-PROPOSED W WATER TREE IH UI LEVELS IFTROTNIE/ICIH FON USE ON PAPER SPACE(SHOWN AT SOX) —T-- TELEPHONE O vA&T/BUILDING STERILE-IXSIINC NOTEI E ELECTRIC OLILVERf SEW SANITARY SEWER(SEW) �i WHO WALL O VAUIT/BUIURNG STORAGE-PROPOSED OODOM ROOM LENGTH CONDUIT CAILOUf-OISING 50 -- STORED IRAN CONDUIT W.coAXWIs FOR USE ON PMBt SPICE(SHORN AT 50X) CRON SIZE.'SUE X X FENCE CONDUIT IRE PPC WITH OR WTIOUi INNER DUCT IMP) DGE �DUCT W.lWuvUC ry— -- CABLE TV POLE ANCHOR/DOWN GUY-EXISTING NO DUCT SM IS —STM-- STEW NO DUCT PPE TANS OIL.-. OIL O NSC.UTILITY POLEANCHOR/DOWN GUY-PROPOSED IDIFS: —:ANIS UNKNOWN UTILDY UTILITY POLE-EXISTING PROPOSED DOWN GUY ON EXISONG ANCHOR O OMIT OWNER,IEIETN —R/W— ROT OF WAY ® �C CONDUIT GON PAP-PROPOSED E� �OF PAVEMENT CONDUIT T P:L91DIA1` FOR USE ON PIPER SPACE(SHAME AT 5010 CONDUIT SIZE:97E NTII OR WIIFOIUT INNER DUCT INFO FACE OF CURB CONDUIT PPE.TYPEIN - FOC POLE-PROPOSED TNR IXKr Om.NNLNDIErs S/W ' LE L3 FDP TERMINATION-EXISTING OFF?DUCT SUE 992T ID NAME INNER TVE WITS SYMBOL DESCRIPTION SIZE HI LOCATION ASW ASPHALT SIDEWALK HH RWOHDE-EMIM ® TERMINATION-PROPOSED O SSTIMED AND TYPE TYPEEE STORE) FOR YON PTT-EXISTING AT 50X) BP BLACK NON PIPE HANDHOIL NAME SPACE OWNER SIZE SOL: BSP BIACK STEEL PPE HH- LOCATION STRATI TYPE HPE STRAND CON PA -PROPOSED CSW CONCRETE SIDEWALK O PR0P0gD BUILDING CA LOT PROPOSED O STUNT LENGTH LENGTH FOR USE ON PAPER SPACE(SHOWN AT 50x) HE NAE1E NOTES: EW EDGE OF PAVEMENTLEVEL3 EVEL3 ,STP�ET EOTW EDGE OF TRAVEL WAY MH- H FOC FACE OF CURB ® MANHOLE-OUSTING MANUFACTURER SEDUCE PANT- EXISTING MANHOLE NAME HDPE HIGH DENSITY POLTLTITILEHE OWNER II HH HANDIOLE ®MANHOLE-PROPOSED NAME SPLICE PGXf-PROPOSED NAME JB JUNCTION BOX MANHOLE (;) Fm�AEf=om��wN wane Nr FINNmRF LEVEL, Y MH WNIOIE N: 0 SEC EIOML CATLOIR A ._.LT IP MILE POSE PB- Fps PILEBox-ExsnD . I 2f24M I » NULL O/S OFFSET OPRX F IN: O SEOUENITR N TAIL OYPOUT . ITE MvrAFc WNE PVC LY NNIL POCHLORIDE [TAL- dry, PB- calll�.Io,„N,aN Lwd(ST.ANMSIN� CenturyLink• RGS RNID GALVANIZED STEEL CONDUIT ®B PILLBOX-PROPOSED #F TAIL 0 SEWENTAL TAIL OUT CALLW7CENTURYLINKLMOINFERTODD --- ILGW TIMiHIE a WAY PEILLBO% OUT: 01EVER, ENGNEERING FRO.WAECO ENGINEER PROJECT NVLBER'nCHC SFA STATEN AocnnoN.PDR PwrecN VN I OR roRn.wo,OR nuI NSIlIIbM 6lme:nF coN�mwva RaovN Trow gran v a. s CONSTRUCTION NOTES (I O EX611NG 111 1EIECDN C'IXAUf PA1H a i @ 2'0'7405 zQ IR EACfP dT n lUKus.Ix vKeP MD se 7409 caaurs rx x'e'wwRac a � I I �— _� RESTORATION NOTES RESIORC nisIA4MV YCIOI a SOEMNI(W GIYPM a SW TECH CENTER DR r p 1 2 — � —rrc—roc--rm— + 5' .,.--,n --�—,^�--•�„ '^Win-- 4'%4'%3'DEEP INTERCEPT PIT a — a a— PORT PLASTICS 7500 SW TECH CENTER DR f� �imloam�m�5Ralo I�unals uo oma�ra m � l� wnr reason�+ Ls•/ao >sN rnw awa✓r, nrt wnw cwurrr rzn ~.below. SOP Canewweweeq. La,W(3T.,.., CenturyLink- c GINMRl Nt FIIW W COoo INEE ENGINEERINOFIRM.WPECO ENGINEERING ffl�ELMAT1 T NIIMBE0.N CH C LOCATION:PSR SW TECX CENTER OR, + PORTLPNO,OR 9Pu3 'NTNG NM1E.r�rem:nnr__ e_rGrrmuv_(6rnEEan 1'.1' eONFIOFN*v.r�PRe�RIE�nRv961 TYPICALS PLANTER 5' MIN. ROW STRIP 6" ROAD f 2" OF 3/4"-0" COMPACTED SUBGRADE J BASEROCK SIDEWALK AWAY FROM CURB 1. CONCRETE SHALL BE 3000 P.S.I. AFTER 28 DAYS. 2. PANELS TO BE 5 FEET LONG UNLESS OTHERWISE SPECIFIED. 3. EXPANSION JOINTS & CONTRACTION JOINTS SHALL BE 1/2" PREMOLDED ASPHALT IMPREGNATED MATERIAL OR EQUAL EXTENDING FROM SUBRADE TO FINISH GRADE AND PLACED AT SIDES OF DRIVEWAY APPROACHES, UTILITY VAULTS, WHEELCHAIR RAMPS AND AT SPACING NOT TO EXCEED 45 FEET. 4. FOR SIDEWALK ADJACENT TO THE CURB AND POURED AT THE SAME TIME AS THE CURB, THE JOINT BETWEEN THEM SHALL BE A TROWELED JOINT WITH A MIN. 1/2" RADIUS. 5. SIDEWALK SHALL HAVE A MINIMUM THICKNESS OF 6 INCHES IF MOUNTABLE CURB IS USED OR IF SIDEWALK IS INTENDED AS PORTION OF DRIVEWAY. OTHERWISE SIDEWALK SHALL HAVE A MINIMUM THICKNESS OF 4 INCHES. 6. DRAIN BLOCKOUTS IN CURBS SHALL BE EXTENDED TO BACK OF SIDEWALK WITH 3" DIAMETER SCHEDULE 40 DWV (ABS OR PVC) PIPE AT 2% SLOPE. CONTRACTION JOINT TO BE PLACED OVER PIPE. 7. CONCRETE SHALL HAVE A MEDIUM BROOM FINISH AND TROWELED ON ALL FOUR SIDES °°'�""°�°" 111\ .t 111-x11 WpO�R NOSC� N/1 p , v2. svrc lwl D,xnLv MICHAEL A. STONE. P.E. o /2D DITE W D Dnlnac coul[ra Ii\GINN.I:pIN1G D1195105 ,„d�I CONCRETE owC. No. wA..n.,Ee,Dw. _�,, vl-Ruc xoprs neenRTN¢�r Level*3 CentUryLink• 2U Call aronyaeg. s„D»'jc I LI3i..p'.IIALL W.\'I9 SIDEWALK HYLINIt[NGINt[N..:DGU Hll TIGARD,IIREGION1•Ifj1 JANUARY 2013 ENGINEERING FIRM.EER OENGINEERING ('. 1 \'flff F=:1VU116MH71 ENUNcE RING FIRM WAECx TAX:(mt)N 'M! WONALalc LOCATION:75 SWTECHCENTERDR. PORTI NO OR 91223 WN N _ M iGxWx: USr.aStes PUGPult�inu�61 SITE PHOTOGRAPHS O CONSTRUCTION NOTES + E�rsnxc T/m trnu mart rem O INTERCEPT DICT WK WERE R TIM b6F,WMUPT CTka/TS NIR SET IEW 2517'HNaaE RESTORATION NOTES �, OA TIM 5'XIO'MESMM OF MEUX N MCF Y.e Y p ',. x u AFI / / �`�t, • ',i 3 p. . LOO V:� _tee M;F�•= "3`RT �l� :* e �1gift FACING EAST ON THE 5OUCH SIDE OF SW TECH CENTER DR NEAR 7500 SW TECH CENTER DR Fnox.,.blow. Call e.w..Tuu al,. awa "M mn +w pow xo. MTE EncDEMM oruvnc IfbOR Level(3J.Ro. ��� CenturyUnk- CENTUMNn ENGMEER:TWD HURD ENGINEERING FNM:WAECO ENGINLLRING PROJECTNLE R'.NWX21 ((f TIM:75W SW TECH CENTER CA, RTURNa GR 9T}9 �i�CVM_o-MhA 14PMWX WPAY NfEyMHAIMIi NEIDENTUURRCPRIETARY sxEET. 6 [f 6