Loading...
Report PPS22t-- ///8,' INTELLIKNIGHT ACCESSORY /,276 's 6? 4ItSILENT 3 \JED Addressable Photoelectric t KNIGHT Juw %4 269 Smoke Detector by Honeywell 3U�\(0,•g,D �etect smoldering fires quickly and get help fast with IntelliKnight® photoelectric smoke detectors. IntelliKnight addressable photoelectric smoke detectors are the clear choice for commercial settings where smoldering fires are a threat. In addition to accurately detecting a smoldering fire, each SD505-PHOTO photoelectric detector has a unique address, which is recognized by the IntelliKnight panel. No precious seconds are wasted in determining location of an alarm. The SD505-PHOTO compensates automatically for contamination in the environment.And detector testing is simple—even from a remote site. Like other IntelliKnight detector models, the SD505-PHOTO offers a low profile for pleasing aesthetics. The IntelliKnight family of detectors has been designed to use a common base, Model SD505-6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight smoke detectors—easy installation, stable operation, RF/transient protection, and vandal-resistant locking—and it adds up to a flexible solution for all your fire protection needs. Model SD505-PHOTO approximately every 15 seconds, Analog/Addressable indicating that the head is Photoelectric Type Smoke communicating with the loop. The Detector LED lights continuously during the The SD505-PHOTO is particularly alarm period. suited to detecting dense smoke Features . typical of fires involving materials • Low profile, 2 inches, including such as soft furnishings, plastic, base foam or other similar materials • Simple and reliable addressing which tend to smolder and produce without mechanical switches large visible particles. Automatic compensation for SD505-PHOTO Smoke Detector •The detector features automatic sensor contamination compensation for contamination • Built-in fire test feature Ambient Temperature: 32°F to and a simple detector calibration • Simple detector calibration 120°F (0°C to 49°C) test procedure that can be run from testing through the control panel the panel or remotely (using the or remotely through a Mounting: 4" Square, 4" OCT, WindowslM based downloading WindowsTM based computer Single gang mud ring software). software. Relative Humidity: 85% non- Operation • Vandal-resistance locking condensing The SD505-PHOTO units made up features Air Velocity: 0 - 300 FPM of an LED light source and a silicon • Field cleanable photo diode receiving element. In a • UL listed, meets NFPA 72 Ch 7 Compatible Bases: SD505-6AB normal standby condition, the requirements (Sold Separately) SD505-61B receiving element receives no light • CSFM approved SD505-6RB from the pulsing light source. In the • MEA approved SD505-6SB event or fire, smoke enters the • FM Approved detector and light is reflected from Specifications - the smoke particles to the receiving element. Operating Voltage: 24-41 VDC The light received is converted into Current Consumption: an electronic signal. Under normal Standby: .55 mA P/N 350225 Rev G conditions, the status LED blinks Alarm: .55 mA ©2015 Honeywell International Inc. INTELLIKNIGHT ACCESSORY Model SD505-PHOTO Addressable Photoelectric Smoke Detector Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable photoelectric smoke detector Silent Knight SD505-PHOTO. The combination detector head, and twist-lock base, shall be U12) listed compatible with Silent Knight's IntelliKnight fire control panels. The base shall permit direct interchange with Silent Knight SD505-HEAT Heat Detector. Base shall be the appropriate twist-lock base SD505-6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SD505-PHOTO shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. NI Diameter=5-15/16" N Diameter = 3-15/16" 0 A l',- -----1' O CD =, 0 ��,� �. Height = 2 inches, including base '' r't t m\tL`i.' ), Model SD505-6AB Detector Base Model SD505-PHOTO Detector Head (front view) (front view) SILENTNI It This document is not intended to be used for installation purposes.We try to keep our KNIGHT product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements.All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: by Honeywell (800)328-0103, Fax: (203)484-7118. www.silentknight.com SYSTEM SENSOR' cm). Indoor Selectable- (41 Output Strobes and Horn Strobes for ` == Ceiling Applications \\' • System Sensor L-Series audible visible notification • products are rich with features guaranteed to cut installation times and maximize profits with lower 02? current draw and modern aesthetics. 111 Features The System Sensor L-Series offers the most versatile and easy-to-use line of horns,strobes,and horn strobes in the industry • Plug-in design with minimal intrusion into the back box with lower current draws and modern aesthetics.With white and red • Tamper-resistant construction plastic housings,wall and ceiling mounting options,System Sensor • Automatic selection of 12-or 24-volt operation L-Series can meet virtually any application requirement. at 15 and 30 candela The entire L-Series product line of ceiling-mount strobes and horn • Field-selectable candela settings on ceiling units: 15,30,75,95, 115,150,and 177 strobes include a variety of features that increase their application versatility while simplifying installation.All devices feature a plug-in • Horn rated at 88+dBA at 16 volts design with minimal intrusion into the back box,making installations • Rotary switch for horn tone and two volume selections fast and foolproof while virtually eliminating costly and time- • Universal mounting plate for ceiling units consuming ground faults. • Mounting plate shorting spring feature checks wiring continuity To further simplify installation,the L-Series utilizes a universal before device installation mounting plate so installers can mount them to a wide array of back • Electrically Compatible with legacy SpectrAlert and SpectrAlert boxes.With an onboard shorting spring,installers can test wiring Advance devices continuity before the device is installed. • Compatible with MDL3 sync module Installers can also easily adapt devices to a suit a wide range of • Listed for ceiling mounting only application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING •e,.�. UL ® r _ APPROVED LISTED S5512 FM approved except P25-1653 C504 S4011 for ALERT models 7135-1653 0503 3057383 L-Series Specifications Architect/Engineer Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box,4-inch octagon back box,or double- gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuit'"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95, 115,150,and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Rang& 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range(MDL3) 8.5 to 17.5V(12 V nominal)or 16.5 to 33 V(24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6.8"diameter x 2.5"high(173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9"diameter x 3.4"high(175 mm diameter x 86 mm high) (SBBCRL,SBBCWL) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDS66860 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) - 8-17.5 Volts 16-33 Volts Candela DC DC FWR 15 87 41 60 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1K Temporal High 111 164 69 94 147 163 184 229 257 3.1K Temporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 • Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 • 3.1K Temporal High 108 135 179 200 225 255 289 3.1K Temporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data Horn and Horn Strobe Output(dBA) 8-17.5 16-33 Volts Volts Switch Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 AVD58680C L-Series Dimensions 2.47 1.37 - - 06.92 —, - 2.50 - 06.83 Q II i 0—TA.91\‘\ o R v-s _ Or 1 1 I. Q • `�: } go ®g iiii, I I /.. Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box A /P,i,,--------,---;:,-;---'s:,‘,.--1„ ---„,,, -ay�Jl� s� p 01 tie ��� yryi y�s�� Ti , tw Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box L-Series Ordering Information Model Description Model Description Ceiling Horn Strobes Ceiling Strobes PC2RL 2-Wire,Horn Strobe,Red SCRL Strobe,Red PC2WL 2-Wire,Horn Strobe,White SCWL Strobe,White SCWL-CLR-ALERT Strobe,White,ALERT Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box,Red SBBCWL Ceiling Surface Mount Back Box,White SYSTEM02017 3yStem Sensor. 3825 Ohio Avenue•St.Charles, IL 60174 Product specifications Subject to change.0than notice.Visa systemsensorcan �� SENSOR' Phone:800-SENSOR2•Fax:630-377-6495 for cooed product information,Inck.clIng toe latest version of this data sneet AvoS86801•03/17