Plans --`i ---- --- w " a Markup Legend SPRINKLER SYMBOL DEFINITION OFFICE COPY COLOR/LINETYPE LEGEND t Delete Une -�`--=,-L 1-- �O�XXX-,,X BLUE LINES=FEED TO FIXTURES(BATH,SHOWER,ETC.). E o GREEN LINES=INTERLEVEL CONNECTIONS/SUPPLY. 0 ' I BLACK LINES=SPRINKLER HEAD TO SPRINKLER HEAD. o -MAXIMUM SPACING(TYP) O Add Ung ......_. _.._. .___. ___. _..- SPRINKLER MODEL(TYP) ��� =1/2"PIPE SIZE W-S-S HEAD SYMBOL(TYP) ...me.= =3/4"PIPE SIZE g a $ Add Tee _T ...maim.. =1"PIPE SIZE -- — f .I'm = 1-1/4"PIPE SIZE 0 W 3 a.:0 Add Elbow L 51,-i2 .., u, Add Coupling I N E g J I. jj CITY OF TIGARD o r 3 Add Head l---,`J, -Y: �‘;,..-..< � Delete Head _, i Approved [X j _ _< Conditionally Approved [ 1 p. E;g o g g s 3 Move Head See Letter to:Follow [ 1 lI<" „A <o< 5 I m Note:An revisions must be reviewed by Uponor �q r Table F002-1 -- ... ... Attached Multipurpose Permit Number:�'►?ST.ZvIs—o0�� _ . ... � 1:..:... .. - . � _—=-----=.i �=o��>== �'°�3 p rpose Fire Safety Systems m i c The Uponor Residential Fire Safety System is a residential fire protections Address: 414 2.38 s w t t "i F i€w 2 R o 2 a` .p4' system installed in combination with the cold side of the domestic potable /! �/') I g r <B o-< 5 water system. Only licensed contractors trained by Uponor can install this By: A-(4,0 Date: 1"'-is-- ��`� ��� W1�1�yy 1ii >o”R y o' I system. Z IFggt.EC `§<i�d F >3 What to do If Changes are Required jf 6 • <S <w! ° � �, If any features or obstructions require the addition or deletion of sprinkler - - j� < o g=.§I z u-�''<o E heads,or significant reiocadon of sprinkler heads,contact the Uponor Design - - -- - -7 C3 tcr..E o 3 rz ,,` m z ° t01,5 to determine if observed changes require a redesign (888.594.7726). Izg � erg�r < g. i iI 5 MOST HYDRAULICALLY REMOTE HEADS < y c HEAD f GPM PRESSURE REQ'D AT STREET I t- ol m4 wi 1 HEAD H.3 13 28.52 a 2(A '� I I �} i � 5 2 HEAD H.9&H.6 26 43.3 > W ,.,U ,, 1 pi , L/ I \ I LF SENJU Model RC-RES Residential Flat Concealed Pendent SS8464 1"AQUAPEX INTERLEVEL 1•AQUAPEX]NTERLEVEL I K=4.9,162F°,7/16"Orifice,Maximum Spacing 16'x16' CONNECTIONS FROM LOWER I FLOOR TO FROM LOWER RECEIVED 0 - P 9 FLOOR TO MIDDLE FLOOR FLOOR TO MIDDLE FLOOR C --� RC-RES-16 Sprinkler head demand:13 gpm @i 7.04 �\�\j / `l�alli 7 ,�C, ____:I -_� J / 4 _ \ -- � DEC 17 2019 Fa LF SENJU Model RC-RES175 Residential Flat Concealed Pendent SS8464 • .•./. 0 - - - 1 K=4.9,175F°,7/16"Orifice,Maximum Spacing 14'x14' v`` �-- o RC-RES-14-175 Sprinkler head demand:13 gpm @ 7.04 r ( _ -I I I \ I CITY OF TIGARD — I I \ c� BUILDING DIVISION \\ N 1 24 g_ - T.24 T..7- �9{7 2Z L \ 8 �-c ' ,�RCRES16 RC-RE' 6 T.28 . co i air.°a M / • �IM Mat I � �� , ' II : a �4 N O N I E.9 ; i F ' w Nr V �P P:__ Wilk 1 oC I L._FLOOR ABQV�,_. J L__.__.___ J LLJ 1— i "• uJ Ru gIi ;:-.1. CURRENT STATIC EXTERIOR WALL Ty-lga, ih Sor WATER PRESSURE _ Porch LU E . ,Tog g 5 STATIC: 55psi li — TO1-1/SYSTRMAPEX I — TO HOT WATER HEATER l Ce z 5 IB 1"WATER METER / s.1 Q 0 8' STANDARD LOSS PER NFPA 13Dti / rt.,ELEv=Soa r Y (3PSI LOSS FLOWING 26GPM) 1 1-1J4"FULL PORT �u ti N BALL VALVE 1 LOWER FLOOR 2 LOWER FLOOR - MIRROR = Q 52%5 4 F100 n n F100 nn (' si N 40 6 / 1/4 = 1 -0 1/4 — l'-0 p I--, _�y- v ELEV=100' ELEV=100' / Ce I— 11 41 ii— i �///////////I --___—__ ccc3333 iiri77J S 1"METER SHEET DESCRIPTION I35'OF 100'OF LOWER FLOOR 1"COPPER-K 1-1/2"AQUAPEX tn 5 0 3 WATER SERVICE DETAIL _ SHEET 5 15 3 PM IN F100 NTS 1/4'=1'-0" r — © UPONOR - CONFIDENTIAL - .a --------------- - — --'---------- --- I Markup Legend SPRINKLER SYMBOL DEFINITION COLOLINETYPE LEGEND a BLUE LINES=FEED TO FIXTURES(BATH,SHOWER,ETC.). F o Delete une �� \ XXX-XX GREENILINES=SPRINKLER HEAD TO SPRINKLER HEAD. Q SUPPLY. Zi Zi o --- �x� =1/2"PIPE SIZE W g o HEAD SYMBOL(TYP) �sr =3/4"PIPE SIZE >'-= Add Line ---- - --- - ---- ----SPRINKLER MODEL(TYP) MAXIMUM SPACING(fYP) ® a� +®u• -�- m S Add Tee ===.1=.== =1"PIPE SIZE — w = 1-1/4"PIPE SIZE 81:'21; d a.w o y y= Add Elbow TLH 5'C.=g Cut^l77 Cpm23Add Coupling I I Om N I-W I Add Head -@--€F)-- -�q C.• 4 Delete Head x - 6E T e i ^w' Move Heed _(.. _,/ I_ A w<vaY itlwt§ Note:All revisions must be reviewed by Uponor q %,°5 U i i 8 —_—_Table P002-1 Lt^ol$a.'',z- .4t< i-. _(±„, "iga �r3 -tz Multipurpose Fire Safety Systems r.{r- h, i� i<<_ The Uponor Residential Fire Safety System is a residential fire protections 1 F tl'gtt 3 - I P0 L'.Q m M system installed in combination with the cold side of the domestic potable __ W m a F<z 3 water system. Only licensed contractors trained by Uponor can install this ' --- --1 f - z o= <r system. —_' --- -- 6J1 r►a 7 c l$i l'd l Pig Q What to do if Changes are Required 1--_ iP z F �< 5 t^ai If any features or obstructions require the addition or deletion of sprinkler \ j i`j D l l i,,11 A E, heads,or significant relocation of sprinkler heads,contact the Uponor Design Li Vin ( 13 m g z F a k V p i, Department to determine if observed changes require a redesign (888.594.7726). 1z0 �' g/� - . fl H.2 FIREPLACE H.2 S , ., 11 °° y� � „Yoe RC-RES-16 FIREPLACE { RC-RES-16 '" w z T.11 T.11 y ��l cl I +— P------------ ii �I-0I F"3 -F.21F.2- F.3 N 1"AQUAPEX INTERLEVEL ---- -� 1"AQUAPEX INTERLEVEL 1"AQUAPEX INTERLEVEL I- III I \ 1"AQUAPEX INTERLEVEL CONNECTIONS FROM LOWER w �,)i«p� �=+CONNECTIONS FROM MIDDLE CONNECTIONS FROM LOWER _ CONNECTIONS FROM MIDDLE FLOOR TO MIDDLE FLOOR \� SD I --- FLOOR TO UPPER FLOOR FLOOR TO MIDDLE FLOOR \ I pZ ' ,i FLOOR TO UPPER FLOOR �N . 5 H.5 c, I � 0 H.5 F.5 • - \ ��- - .�8 T.18 \ I T.18 7,16 ,,- - cy-_Co / \\ I 0_-(,)- ,,- 11 j \�� 6 ' I= / \\ x< ►- E I' •�•, — �.�� 1atitte_; A MNI • —. \ . , 1i 2St- y i._ II T.26 (n T.25 _T.ri. - F T � �C y�g x .'§ g �l ! .8� j . , H.81 I LLI U s�o�• ��•� y \ •NR 166 gre': t. . ► act 'IC 1.1 II ;� T.33 �� �i` . 4 C.0 _ N -/s�� I Cil I " — LLI €2 o ,y� � I r� G_ cc l--171: Fs! ! L�� ) T_-..t.111-- t�L _ --1 LI- — "- _ Y.-_-1. �' j 8 8 is OL _J ..... —t �!- L___I Y ilia C O = 'i MIDDLE FLOOR 2 MIDDLE FLOOR - MIRROR Q o tz Pe I, F1O1 1/4" _ 1l_0" F101 1/4" = li_0il o ' =Y S SHEET DESCRIPTION a MIDDLE FLOOR 0 a .2 SHEET NUMBER 5 0 5 15 t• !SiTld!cmommmik 3 I I. 1/4•.1-0' F101 _' © UPONOR - CONFIDENTIAL i Markup Legend SPRINKLER SYMBOL DEFINITION .%1COLOR/LINETYPE LEGEND BLUE LINES=FEED TO FIXTURES(BATH,SHOWER,ETC.). s o Delete Line i'' /\ kfiA XXA-:X GREEN LINES=INTERLEVEL CONNECTIONS/SUPPLY. „ u / -MAXIMUM SPACING(TYP) BLACK LINES=SPRINKLER HEAD TO SPRINKLER HEAD. a SZ` ===.1....= =1/2"PIPE SIZE >n,g Add Use --- -- --- -- ---- -SPRINKLER MODEL(TYP) W --HEAD SYMBOL(TYP) ======= =3/4"PIPE SIZE s m r � u Add Tee �laaa� =1"PIPE SIZE �N�� =1_1/4,.PIPE SIZE 0 to i LL W o d 5? �z Add Elbow 11 ,2? 1 ,2? W t W Aad Coupling I M t9 V i of 3 Add Head -- 2- 3- StA..m3 W Delete Head -, _ 1 ` °1.5 l'i o -,x ,ave Head - ' `G- l g l<Pil it g i � Note All revisions must be reviewed by Uponor m111" ir�o ui4 3 Table 1,002-1 aY�Q8t5t� Multipurpose Flre Safety Systems ; 'm 1 1 1 1 m The Uponor Residential Fire Safety System is a residential fire protections 1r-,y ROOF r;x o i 9 AA a 8 0 system installed in combination with the cold side of the domestic potable M y-t-= -----1 I -- W m"M1,... ..< 4 V i g i water system. Only licensed contractors trained by Uponor can install this J —-—�--- 1 -`� - ___ C _, t ..,o K s 1 A>. system. What to do if Changes are Required / N-i I ita L�7 <5a3 g `� o If any features or obstructions require the addition or deletion of sprinkler - __.-- en -e W heads,or significant relocation of sprinkler heads,contact the Uponor Design C o� i l g r<E`.u 8 uC Department to determine If observed changes require a redesign rte," �x� I 1 1 z u , v� (868.594.7726). ,dQ`oom 2 I H.1 � soR IH.1 til o ; 16< IRC-RES-16 ' RC-RES-16 iii ° g re-\ 1 //.-') IIIihliIPJli trti.10 ...., ti` LI , / 10 II 1(1 1 T13 ' ) SD/CM ii 1�I� ~ H M�Z , , F.1 \N R -• . , \ 1'AQUAPEX INTERLEVEL '- _it, 16 _ !u \ 1"AQUAPEX INTERLEVEL —_ CONNECTIONS FROM MIDDLE ` + CONNECTIONS FROM MIDDLE I iI T.14 III I --'4 y FLOOR TO UPPER FLOOR �; Iii pag , ff 1 f FLOOR TO UPPER FLOOR 1,, F4 wtj ..._ - 1 / 1 4 ) 1 f1J.�t4 — 6> __ 1 t 1_ / vn:S-14- �� ' 0 1; I TAT - �.� / i �' 7 .- I a i I' d, T 19 RES-16/ RC-RE ' a Y I �r � � x.1.9OPEN , OPEN TO Ute,ii V9BELOW (�'� C?r I BELOW a I/'____' - "T_`_ 00 2 1 1.23' 1 _ =x rye, 1. I ;T.23 t �§ - LJ� i Ire I I RC-RES-16 RC-RES-16$_ i w •s . I— « Ug cc o z Q 4 a 1 UPPER FLOOR 2 UPPER FLOOR - MIRROR Q o izi F102F102 1/4" = l'-0" 1/4" = 11-0" to < o; .. g 5 ia5 §2' g SHEET DESCRIPTION UPPER FLOOR 0 c' L SHEET NUMBE0R 5 o S 15 O F- .. 1/4 .1'-0' 2 igI © UPONOR - CONFIDENTIAL TM Senju RC-RES:Open Web Truss/TJI Construction Insulation Recommendations r A uaSAFE GENERAL NOTES: See General Notes 8.2.5.7 for Architectural Q In areas subject to freezing,care should be taken In unheated attic spaces ProPEX LF Brass Fire--- m to cover Uponor AquaPEX tubing completely with insulation. Insulation Feature Requirements x, Sprinkler Adapter Tee should follow the guidelines of the insulation manufacturer. See Uponor _____. ` z s 1. THIS SYSTEM IS DESIGNED AS PER NFPA 130 2016 EDITION AS A RESIDENTIAL MULTIPURPOSE SYSTEM Fre Sprinkler Adapter AquaSAFE Attic InsuhNon Guidiinaa"for attic --- SECTION 3.3.11.3. Blocking Maybe-- P P Document"Uponor --- Push-on Nut guidelines(Providedpackage or online 0 Required.If installation In Contractors Documents 2. UPONOR COMPANY RESERVES THE EXCLUSIVE RIGHTS TO ALL DETAILS AND DRAWINGS AS SHOWN ON Blocking is Used, ` •• _ at www.0 n z THIS SHEET.THESE DETAILS Use The 2 Top 1 L/�All (w_orpro.com). z--- - z AND DRAWINGS ARE PROPRIETARY INFORMATION OF UPONOR COMPANY AND I II 1 Lz"Max.x UNAUTHORIZED USE MAY BE SUBJECT TO PROSECUTION TO THE NULL EXTENT OF THE LAW. Screw Holes. J3 ■0 eouom of Mounting Extreme Temperature Installations Planter Box Window,Bay Window or Similar Feature. w"1 g O Market to Face or Truss If no additinal floor area Is created No Addjtlonal Sz�Nnklar Ip Required. P;',44 AquaSAFE Residential Fire Safety systems are often instated in attics or 3. THE DESIGN OF THIS SYSTEM IS DICTATED BY SPECIFIC CEILING HEIGHTS AND ROOM SIZES. IT IS THE Fire Sprinkler Adapter- other areas exposed to temperature extremes of heat and/or cold. Follow IV-War leas RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO ENSURE THAT THE CONDITIONS SHOWN ON THESE \s_�� II,, Mounting Bracket the recommended extreme weather installation instructions to isolate and / �( 0 ,f,;15 o, PLANS ARE EXACTLY AS THEY EXIST IN THE FIELD. DEVIATIONS FROM THE DESIGN MAY CAUSE THE `_-� protect system components from extreme temperatures. Because this RC-RES-16-I N SYSTEM TO BE UNABLE TO CONTROL A FIRE.IF THE BUILDING CONSTRUCTION DIFFERS FROM THE FIRE - SPRINKLER PLAN,CONTACT THE SYSTEM DESIGNER IMMEDIATELY. 3-510 x 1/Y _ system also delivers domestic cold water directly to plumbing fixtures, 9'-0•or less 0 -� Q 'o z g Full Cou Uponor highly recommends that you protect the tubing with adequate / N n 0 4. THIS SYSTEM AND THE ACCOMPANYING HYDRAULIC CALCULATIONS ARE DESIGNED IN COMPLIANCE WITH Thread S•-ws a mu `; insulation in warm weather areas to minimize heating of the cold water N r w; NFPA 13D 2016 EDITION. In Botto Holes supply. I? II 5. "STAND-ALONE"OR"MULTIPURPOSE,WET PIPE'SYSTEMS ARE NOT PERMITTED TO USE ANTI-FREEZE. Installation methods include,but are not limited to: I _ \ v a s" �---• • Tentingover the ire sprinkler piping. a m t-W 3 6. MODIFICATIONS ARE PROHIBITED.SPRINKLERS THAT HAVE BEEN PAINTED,CAULKED,MODIFIED OR Lead-F-=Flat p ti p�' DAMAGED MUST BE REPLACED. Conceale. u ="-=--- • Additional layers of batt insulation. If additional floor area is created.Cannot exceed 18 ft,be more than 2'-0" Sprinkler Head -- --Concealed Flat • Increased depth of blown-in insulation. deep,more than 9'-0"wide and be with in the coverage area of the < 2 -� Cover Plate sprinkler.No Additional 5 Inkier is aired. 0 it m 7. WATER SHUT OFF VALVE IS NOT PERMITTED THAT ISOLATES THE SPRINKLER SYSTEM. Pd -----Re4-- . ' "'= Caution: If you will be instating spray foam insulation,make sure to 6'1'P !r i C i 8. OWNERS MANUAL MUST BE PROVIDED TO THE OWNER. Senju RC-RES:Traditional Wood Framing Construction protect all components during application.Consult with the spray foam =i?< S S d i manufacturer to ensure compatibility with all products before application. NFPA 13D Table 7.5.5.3 Distances From g i Q o < i 9. AT THE MAIN SHUT OFF VALVE,A TAG OR A SIGN STATING THE FOLLOWING IS REQUIRED;"WARNING,THE Heat Sources g d *,g"S 4 2•', WATER SYSTEM FOR THIS HOME SUPPLIES FIRE SPRINKLERS THAT REQUIRE CERTAIN FLOWS AND Consultation with local building offdals is encouraged to ensure compliance yy w C •. z� PRESSURES TO FIGHT A FIRE.DEVICES THAT RESTRICT THE FLOW OR DECREASE THE PRESSURE OR ProPEX L Brass Fire - -' with local building codes. - �uu g 6 f S •r t-a1 AUTOMATICALLY SHUT OFF THE WATER TO THE FIRE SPRINKLER SYSTEM,SUCH AS WATER SOFTENERS, Sprinkler apter Tae Fire Sprinkler Adapter Ordinary InEsrmediata E o i ° y FILTRATION SYSTEMS AND AUTOMATIC SHUT OFF VALVES,SHALL NOT BE ADDED TO THIS SYSTEM a • Push-on Nut Heat Source Temp. Temp. d•: 9E u d WITHOUT REVIEW OF THE FIRE SPRINKLER SYSTEM BY A FIRE PROTECTION SPECIALIST.DO NOT REMOVE SSS°-170• i7S•-215• °>it�s m< ' Qz THIS SIGN'. Bending PEX Tubing z5a° ■ ■ Side of Fireplace 36" 12' p p a:' ""jI IC', 11/4"min. The minimum bend radius of Uponor PEX tubing In any direction is six times pl �. g< r= 10. ALL INTERIOR PIPING TO BE UPON00." I ' Front of Fireplace 60' 36' _ W 33 m '3 g R AquaPEX(9"UNLESS NOTED. 1(/z'Max. the outside diameter(6 x OD). ° ,- •t >g Fire Sprin der Adapter If Bottom N MdxNrg Bend supports are available For 3/8",1/2",3/4"and 1"Uponor AquaPEX WOOd Burning Stove 42" 12' M a <> i 11 Mg ?F UPONOR"AquaPEX"TUBING TO BE SUPPORTED PER NFPA 130 AND MANUFACTURER'S RECOMMENDATIONS. MountingBracket BradcN to Tau of Truss ` -� -_ tubing to facilitate 90-degree rigid bends. Kitchen Range 18' _ 9' 5i340,311 1°3 12.MINIMUM SPACING BETWEEN SPRINKLERS IS B'-0"REFER TO SPACING CHARTS FOR MAXIMUM SPACING .Q -� --- ------- ____ Wall Oven 18• 9' Ll .S" � 2-#10 x 1JY • • Recommended Tubing Length Between Fittings Hot Rues IB' 9• r7Rt <$ 1$ r o i; BETWEEN SPRINKLERS AND FROM WALLS.SPRINKLER HEAD MANUFACTURERS MAY HAVE MORE Full Coo `� c� I RESTRICTIVE SPACING LIMITATIONS. Thread ws • _ _ Pitting Size Minimum Tubing Length Unlnsulated Heat Ducts 18' 9" C i g a F u a, B ur u In Top H e5 i t�1 3/8"ProPEX Fitting 2• - Uninsulated Hot Water Pipes 12' 6' . 1 o q� $°g g °' 13.SPRINKLERS ARE NOT NECESSARILY CENTERED IN ROOMS DUE TO LIGHT FIXTURES OR OTHER CEILING Side of Mot Air Diffuser 24• 12' u s z MOUNTED OBSTRUCTIONS. 1/2'ProPEX FRtin 2 1/2" - i °<. °"g,�+S"''z g Front d Hot Air Diffuser 36' 18' °I•'S S O a vi 14.THE PLUMBING TIE IN CONNECTIONS ARE SCHEMATIC IN NATURE AND CAN BE INSTALLED OFF THE 3/4'ProPEX Fitting 3 1/2" ----- - °g LL 1 m z Hot Water Heater 6" 3' °°tigdR" SPRINKLER LOOP ANYWHERE BETWEEN SPRINKLER TO SPRINKLER CONNECTION. lead-fret Flat Fitting -_ W d g. 0 6 0°z }Q Concealed n u -Concealed Flat 1'Pno�X4 1/2" Furnace -__-- 6' 3" v,a m W <�,C Sprinkler Head 50W-250WLight Fixture 6' 3" - "° 1611 i "' 15.THIS SUGGESTED LAYOUT IS BASED UPON INFORMATION PROVIDED BY OTHERS. CHANGES IN Cover Plate 1 1/4"ProPEX FItting 5 112• Li _ yii" ", zu-o CONSTRUCTION OR FIELD CONDITIONS MAY OCCUR WHICH MAY REQUIRE CHANGES TO THE LAYOUT. IT IS ----"------'------- -- -- 250W-499W Light Fixture 12' 6" E>3=E g Fig THE RESPONSIBILITY OF THE INSTALLER TO NOTIFY UPONOR TECHNICAL SERVICES OF SUCH CHANGES. I„, z x v� l 16.NFPA 13D 8.2.5*OBSTRUCTIONS TO RESIDENTIAL SPRINKLERS Exposed Installation Requirements. ` • 8.2.5.6* SHADOW AREAS SHALL BE PERMITTED IN THE PROTECTION AREA OF A SPRINKLER AS LONG AS Uponor Aings a T"'tubing(white)and ProPEX'EP Fittings and following TM I THE CUMULATIVE DRY AREAS DO NOT EXCEED 15 FP PER SPRINKLER. Brass Fittings are approved for exposed installation where the • 8.2.5.7 SMALL AREAS CREATED BY ARCHITECTURAL FEATURES,SUCH AS PLANTER BOX WINDOWS,BAY conditions are met.(UL 1821 Approved) WINDOWS,AND SIMILAR FEATURES,SHALL BE EVALUATED AS FOLLOWS: (1)WHERE NO ADDITIONAL FLOOR AREA IS CREATED BY THE ARCHITECTURAL FEATURE,NO Exposed Wood 3oist Ceiling Assemblies. 8 F a CTE ADDITIONAL SPRINKLER PROTECTION IS REQUIRED. 1. Joists are of dimensional lumber,engineered wood,wood I-joist or open p1 ' °m (2)WHERE ADDITIONAL FLOOR AREA IS CREATED BY AN ARCHITECTURAL FEATURE,NO ADDITIONAL web wood joists. ,if- -- ,),, m SPRINKLER PROTECTION IS REQUIRED,PROVIDED ALL OF THE FOLLOWING CONDITIONS ARE MET; 2. Joist are of depths from 6-16 inches(152-204 mm). (a)THE FLOOR AREA SHALL NOT EXCEED 18 FT°(1.7 Ma) I 3. Joist are of spacing from 12-24 inches(305-610 mm)on center. \ d0 (b)THE FLOOR AREA SHALL NOT BE GREATER THAN 2 FT IN DEPTH AT THE DEEPEST POINT OF 4. Joists can be exposed after installation. - --{-' THE ARCHITECTURAL FEATURE TO THE PLANE OF THE PRIMARY WALL WHERE MEASURED 5. Metal pipe hangers spaced at maximum 24 Inches(610 mm)on center 1.55"- / 166" _ ALONG THE FINISHED FLOOR. are used. E i (c)THE FLOOR SHALL NOT BE GREATER THAN 9FT IN LENGTH WHERE MEASURED ALONG THE 6. Listed residential automatic sprinklers of maximum activation g PLANE OF THE PRIMARY WALL. liu-4"Hanger 1"Hanger . (d)MEASURED FROM THE DEEPEST POINT OF THE ARCHITECTURAL FEATURE TO THE SPRINKLER temperature rating of 155°F(68°C). SHALL NOT EXCEED THE MAXIMUM LISTED SPACING OF THE SPRINKLER. Tubing Support Spacing: M (3)THE HYDRAULIC DESIGN SHALL NOT BE REQUIRED TO CONSIDER THE AREA CREATED BY THE Metal Tubing Support. (Anchor AquaPEX Tubing Securely Enough to Support the Tubing,Yet Relaxed a, 2. Do not use supports FEATURE. 1. Metal tubing supports designed for plastic tubing shall be used. Enough to Allow the Tubing g to Expand and Contract) that will damage the tubing.Inspect metal .7.NFPA 13D 8.3 LOCATION OF SPRINKLERS. supports for sharp edges. 1. Along Horizontal Runs,Install Supports Every 32",if Horizontal Runs are $ • 8.3.1 SPRINKLERS SHALL BE INSTALLED IN AU.AREAS EXCEPT WHERE OMISSION IS PERMITTED BY 8.3.2 3. Do not rigidly anchor Uponor AquaPEXTM tubing with supports.Allow Continuously Supported,Place Tubing Supports at Six-Foot Intervals. • • THROUGH 8,3.8. enough tubing for freedom of movement to expand and contract. 2. Along Vertical Runs,Install Supports Every Four to Five Feet,at Each 8.3.2 SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF 55 FT°(5.1 M°)AND LESS Floor and at a Mid-story Guide. cXD t3' g • 8.3.3 SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS,LINEN CLOSETS,AND PANTRIES THAT MEET ALL OF THE FOLLOWING CONDITIONS: Y (1)THE AREA OF THE SPACE DOES NOT EXCEED 24 FT•(2.2 M•). In-line Flow Test �' The In-line Flow Test can be constructed on site. It performs a flow test to g• (2)THE WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE Standard Riser Assembly ensure proper system operation and flow(see Figure F001-8). 'T' o',T • MATERIALS AS DEFINED INB NFPA 220,STANDARD ON TYPES OF BUILDING CONSTRUCTION. 8.3.4* SPRINKLERS SHALL NOT BE REQUIRED tN GARAGES,OPEN ATTACHED PORCHES,CARPORTS,AND In multi-purpose systema single control valve controls both domestic and LLJ -w p H, SIMILAR STRUCTURES fire safety needs. / , s • m iJ • 8.3.5 SPRINKLERS SHALL NOT BE REQUIRED IN ATTICS WITH OR WITHOUT STORAGE,PENTHOUSEUponor AquaPEX v igROIIL clf ci EQUIPMENT ROOMS,ELEVATOR MACHINE ROOMS,CONCEALED SPACES DEDICATED EXCLUSIVELY TO AND j 7_4 / Q - CONTAINING ONLY DWELLING UNIT VENTILATION EQUIPMENT,FLOOR/CEILING SPACES,ELEVATOR SHAFTS, % N % ,i, E CRAWL SPACES,AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENDED FOR LIVING Ce PURPOSES. 8.3.5.1 SUCH SPACES THAT CONTAIN FUEL-FIRED EQUIPMENT SHALL ALSO COMPLY WITH 8.3.5.1.1 OR .Q- I.' ` =C S UNIT, .2. -..."----4 S 6.3.5.1.1 WHERE THE FUEL-FIRED EQUIPMENT IS ABOVE ALL OF THE OCCUPIED AREAS OF THE DWELLING / V Z O tI N •• UNIT,NO SPRINKLER PROTECTION SHALL BE REQUIRED IN THE CONCEALED SPACE. W 8.3.5.1.2 WHERE FUEL FIRED EQUIPMENT IS BELOW OR ON THE SAME LEVEL AS OCCUPIED AREAS OF THE Male Threaded Coupling--- ProPEX Fire (jJ _o p O DWELLING UNIT,AT LEAST ONE QUICKRESPONSE INTERMEDIATE TEMPERATURE SPRINKLER SHALL BE111110,:. Sprinkler Adapter 0 INSTALLED ABOVE THE EQUIPMENT OR AT THE WALL SEPARATING THE SPACE WITH THE FUEL-FIRED EQUIPMENT FROM THE OCCUPIED SPACE. inl 1"Ball Valve Fy Y • 8.3.6 SPRINKLERS SHALL NOT BE REQUIRED IN COVERED,UNHEATED PROJECTIONS OF THE BUILDING AT • F; -To Hot Water Heater Male Threaded Coupling----_ • ENTRANCES/EXITS AS LONG AS THE DWELLING UNIT HAS ANOTHER MEANS OF EGRESS. 8.3.7 SPRINKLERS SHALL NOT BE REQUIRED FOR CEILING POCKETS THAT MEET THE FOLLOWING -Female Threaded ,.,/ CONDITIONS: -�-' E (^ • '�I Tee with Water L•L• I- (1)THE TOTAL VOLUME OF ALL UNPROTECTED CEILING POCKETS IN A COMPARTMENT DOES NOT EXCEED ' .. _ Pressure Gauge 0 q g Sprinkler Orifice---- (Optional) Q 41g OOG Li 100 FT (2.83 Ma). rn N (2)THE ENTIRE FLOOR UNDER THE UNPROTECTED CEIl1NG POCKET IS PROTECTED BY THE SPRINKLERS x Warning g N 4 1e or tjj AT THE LOWER CEILING ELEVATION. -- --Uponor 5i ns Flow Test i r'3j3'Sk7 (3)*THE INTERIOR FINISH OF THE UNPROTECTED CEILING POCKET EXCLUDING DECORATIVE •.. TREATMENTS I5 NONCOMBUSTIBLE O0.LIMITED-COMBUSTIBLE MATERIAL. �• H To ensure the system provides enough water for proper Flre sprinkler N.�.,.�•� (4)SKYLIGHTS NOT EXCEEDING 32 FT.(2.97 M.)SHALL BE PERMITTED TO HAVE A PLASTIC COVER. performance,you should conduct a Tow verification test. 8.3.8 SPRINKLERS SHALL NOT BE REQUIRED IN CLOSETS IN GARAGES AND EXTERIOR CLOSETS Q j= n • (REGARDLESS OF SIZE)LOCATED ON EXTERIOR BALCONIES,EXTERIOR BREEZEWAYS/CORRIDORS,OR c Note: The NFPA 13D Installation Standard does not require Flow V/ f r1 � �G • ACCESSED FROM OUTDOORS WHERE THE CLOSET DOES NOT HAVE DOORS OR UNPROTECTED verification. V PENETRATIONS DIRECTLY INTO THE DWELLING UNIT. s Main Fire Sprinkler O L~L� +_ $ 8.3.9 SPRINKLERS SHALL BE INSTALLED IN ANY CLOSET USED FOR HEATING AND/OR AIR-CONDITIONING fr Z Shut-off Valve Before performing a flow verification test,confirm the water pressures by r g Hag z contacting the Water and Sewer Department of your local city. Ensure the UIPMENT,WASHERS AND/OR DRYERS,OR WATER HEATERS EXCEPT AS ALLOWED BY 8.3.8. c available water pressure matches the pressure used in the system design. --------- rQ 18. INSULATION GUIDE LINES PER NFPA 13D. 1 SHEET DESCRIPTION •M 9.1.1*WET PIPE SYSTEMS IN AREAS ABOVE 40°f. A WET PIPE SYSTEM SHALL BE PERMITTED TO BE TO BE - Note:The sprinkler plan indicates the most hydraulically remote sprinkler USED WHERE ALL PIPING IS INSTALLED IN AREAS MAINTAINED ABOVE 40°F,INCLUDING AREAS PROPERLY 8 (or pair of sprinklers). For test requirements on other sprinklers,consult GENERAL NOTES&DETAILS I INSULATED TO MAINTAIN 40°F. your local code. A.9.1.1 IN AREAS SUBJECT TO FREEZING,CARE SHOULD BE TAKEN IN UNHEATED ATTIC SPACES TO Note: Itis a good idea to notify the ire Inspector at least 24 hours prior to COVER SPRINKLER PIPING COMPLETELY WITH INSULATION. INSTALLATION SHOULD FOLLOW THE performing a flow veirifcation test.This may speed up the inspection GUIDELINES OF THE INSULATION MANUFACTURER.FIGURE A.9.1.1(A)THROUGH FIGURE A.9.1.1(F) process and eliminate the need in repeat the test for the inspector. SHEET NUMBER SHOW SEVERAL METHODS THAT CAN BE CONSIDERED.THESE ARE FOR ILLUSTRATIVE PURPOSES ONLY. Nota: See"AquaSAFE Flow Test Instruction Sheet"(Provided In CONSULTATION WITH THE GENERAL CONTRACTOR AND/OR OWNER IS RECOMMENDED TO ENSURE 3 PROPER METHODS AND MATERIALS ARE USED TO MAKE SURE 40°F WILL BE MAINTAINED. _1_ Contractors Documents package or online at www.U,_ponIng the Test for I 1 - - more Information on Flow Test Setup,Assembly,Performing the Test and v Troubleshooting. If there are any y questions please contact Uponor. ., © UPONOR - CONFIDENTIAL FO 0 1