Loading...
Report /c./493.2c9/9—a /58 /6„.74i0 40/ st/fi,c tfuly' RECEIVED Fire Sprinkler / Alarm DEC 1 8 2019 CITY OF TIGARD BUILDING DIVISION Monitoring System Submittals Site: Planet Fitness (Tigard, OR) 1f5410 S /64 ,, 7/47-)Y Tigard, OR 97224 �V Submitted by: MSE ELECTRIC, Inc. CCB# 52273 WA# MEELEE941L3 15708 NE 81st Ave Vancouver, Washington 98662 (360) 253-0176...Voice (360) 573-0459...Fax mandeelectric( comcast.net Supervising Electrician: M & E Electric, Inc. Mike Wooldridge OR Supervisor 3341S Planet Fitness (Tigard, OR) Operational System Matrix .ter r zit \ �� ao as 4, o,.q, �o Q ? o a �r coin wya� (z? der �o � 4442' y�� '��� e Q O Qqq- co co 0 O� co k Oo C) 0 Gy 0 0 .Z*, Waterflow(Wet) (1) • • IN NI NI Waterflow(Dry) (1) • N - • Valve Tamper(4) • • • Low Air, Dry System (1) • IN Smoke Detector(1) I IN IN Pull Station (2) • Duct Detectors (6) 1111 I• NI NI System Wining Fault AC Power Fault III IN Telephone/Communication Fault NI NI IN POTTERProject Name:(Planet Fitness -1 Standby Hours: 24 --I The Symbol at Protection 'Tigard,OR I Alarm Mins: 5 Potter AFC-1000 Installed By:1M&E Electric,Inc. I Batt Efficiency: 80% Battery&Voltage Drop Designed By:(Donald Allen I SIC Type: Class B Calculations Date:112/18/2019 I NAC Source voltage: 20.4 Model ti: AFC-1000 Max Panel Current(amps): 10 Panel ID:I 1 User assumes all responsibility to ensure the quantities and --- Location:I current draw values in this worksheet are accurate prior to --- -- - submittal. FACP Standby(amps) Alarm(amps) Qty Part it Description Each Total Each Total 1 AFC-1000 Analog Addressable FACP . 0.130 0.130 0.220 0.220 Panel Standby: 0.130 Panel Alarm: 0.220 P-LNI((RS-485)(Both P-Linl<Circuits Combined) Standby Alarm 1 UD-1000 DACT Card 0.016 0.016 0.023 0.023 1 RA-6075 LCD Annunciator 0.020 0.020 0.025 0.025 RA-6500F Flush Mount LCD Annunciator 0.020 0.050 LED-16F Flush Mount LED Annunciator 0.025 0.025 LED-16F LED Annunciator LED Power* 0.015 0.210 CA-6500 Class A Module 0.060 0.100 PSN-1000(E) Power Expander 0.015 0.015 _NOHMI-SLCE-127* SLC Expander(9 Max) 0.060 0.060 PAD100-SLCE-127 SLC Expander(9 Max) 0.060 0.060 _RLY-5 Relay Expander 0.025 0.035 RLY-5 Relay Expander Power* 0.010 0.135 DRV-50 LED Driver Module 0.025 0.025 DRV-50 LED Driver Module LED Power* 0.010 0.215 FCB-1000 Fire Communications Bridge 0.025 0.025 FIB-1000 Fiber Interface Board 0.030 0.030 MC-1000 Multi-Connect Expander 0.010 0.010 SPG-1000 Serial Parallel Gateway 0.040 0.040 *REQUIRED IF USING NOHMI PROTOCOL SLC DEVICES (Maximum current draw is 1 Amp per P-Link circuit,with 2 amps total) P-LINK Standby: 0.036 P-LINK Alarm: 0.048 *Only enter quantity If PLINK power is being used to power devices SLC Devices Standby Alarm 1 PAD100-PD Analog Photo Smoke 0.000300 0.000300 0.000300 0.000300 PAD100-PHD Analog Photo Smoke/Heat 0.000300 0.000300 PAD100-HD Analog Fixed Temp Heat 0.000300 0.000300 PAD100-CD Analog Carbon Monoxide Detector 0.000300. 0.000300 PAD100-ORTS Duct Remote Test Switch 0.010000 0.015000 PAD100-DUCT Addressable Duct Detector 0.000300 0.000300 _ PAD100-DUCTR* Addressable Duct Detector w/Relay 0.000500 0.000500 PAD100-PSSA/PSDA Addressable Pull Station Single/Dual Action 0.000200 0.000200 PAD100-MIM Micro Input Module 0.000200 0.000200 _ PAD100-SIM Single Input Module 0.000240 0.000240 2 PAD100-DIM Dual Input Module 0.000240 0.000480 0.000240 0.000480 4 PAD100-RM Relay Module 0.000240 0.000960 0.000240 0.000960 6 PAD100-0R01 One Relay One Input Module 0.000240 0.001440 0.000240 0.001440 _ PAD100-TRTI Two Relay Two Input Module 0.000240 0.000240 _ PAD100-2M* Conventional Zone Module 0.000240 0.000240 PAD100-NAC* Notification Appliance Circuit 0.000200 0.000200 PAD100-SM Speaker Module 0.000200 0.000200 _ PAD100-IM Isolator Module 0.000150 0.000150 PAD100-LED LED Module 0.000240 0.000240 PAD100-LEDK Addressable LED w/Key Switch 0.000200 0.000200 PAD100-SB* Addressable Sounder Base 0.000200 0.000200 PAD100-RB Addressable Relay Base 0.000200 0.000200 PAD100-IB Addressable Isolator Base 0.000150 0.000150 PSA Analog Photo Smoke 0.000325 0.000325 _PSHA Analog Photo Smoke/Heat 0.000325 0.000325 RHA Analog Rate of Rise Heat 0.000325 0.000325 - FHA Analog Fixed Temp Heat 0.000325 0.000325 DDA Addressable Duct Detector 0.000325 0.000325 APS-SA/APS-DA Addressable Pull Station Single/Dual Action 0.000325 0.000325 MCM Mini Contact Input Module 0.000325 0.000325 SCM-4 Single Contact Input Module 0.000325 0.001000 DCM-4 Dual Contact Input Module 0.000325 0.001000 TRM-4 Twin Relay Output Module 0.000325 0.001000 _CIZM-4* Conventional Zone Input Mod 0.000325 0.001000 MOM-4* Monitored Output Module 0.000325 0.001000 ARB* Detector Base w/Relay 0.000325 0.000325 ASB* Detector Base w/Sounder 0.000325 0.000325 SCI** Short Circuit Isolator(Class A) 0.000325 0.002340 AIB*0 Detector Base w/Isolator(Class A) 0.000325 0.002340 IM/IB/SCI/AIB Class B** Current Draw from Install Manual _-1 I. 1 SLC Loop Alarm LED Current 0.000000 0.000000 0.036000 0.036000 * Requires Aux Power(Configure Below) SLC Standby: 0.003180 SIC Alarm: 0.039180 ** See the installation manual for special considerations when installing IM,IB,AIB, SCI devices on Class B loops. Potter Electric Signal(C)2017 1 of 5 AFC-4000 Battery and Voltage Drop Calculation NAC Circuits(See NAC Configuration below) Standby(amps) Alarm(amps) Ckt Use Description Total Total 1 Notification Cir.#1,Training,Main Area 0.00000 1.36600 2 Cir. #2.Main Area 0.00000 1.38900 3 Notification Cirt.#3,Locker/Tanning Area 0.00000 0.68900 4 Notification Circ.#4,Locker Room 0.00000 0.56800 5 Unused 0.00000 0.00000 _ 6 Notification Outdoor H-S 0.00000 0.14000 NAC Standby: 0.00000 NAC Alarm: 4.15200 I/O Circuits(See I/O Configuration below) Standby(amps) Alarm(amps) Ckt Use Description Total Total 1 Notification Cellular Monitor 0.00000 0.00000 2 0.00000 0.00000 3 0.00000 0.00000 4 _ Emergency Comm Monitor 0.00000 0.00000 I/O Standby: 0.00000 I/O Alarm: 0.00000 Battery Calculation Summary Standby(amps) Alarm(amps) Panel Current: 0.13000 0.22000 P-Link Current: 0.03600 0.04800 SIC Device Current: 0.00318 0.03918 NAC Circuit Current: 0.00000 4.15200 I/O Circuit Current: 0.00000 0.00000 SLC Loop Type: Class B Total Standby: Total Alarm:ammimm Device Addresses Used:momml Standby Hours: 24 Alarm Mins: 5 Device Addresses Available: 127 AH Required: 4.07 AH Required: 0.38 Total Combined Standby&Alarm AmpHours Required: 4.45 Efficiency Factor: 80% Required Battery AmpHours: 5.56 Battery AmpHours Provided:I 71 Note:The cabinet will house two 8 AH or 18 AH batteries. The charging circuit is rated for up to two 55 AH batteries. Potter Electric Signal(C)2017 2 of 5 AFC-4000 Battery and Voltage Drop Calculation C)parrER NAC Circuit Configuration& Voltage Drop Planet Fitness 12/18/2019 NAC 1 MAX Circuit Current(amps): 3 Source Voltage Used(VDC): 20.4 Usage:(Notification 1 Description:IClr.#1,Training,Main Area Wire Type Ohms/1000ft Length 1-Way Actual Ohms Max Load(amps) Volta @ EOL Min Volts Req'd #14 Solid 23 300 1.500 1.366 18.35 16 Circuit Devices Standby(amps) Alarm(amps) Qty Lookup Type Description Each Total Each Total 2 Horn Strobes Potter CHS-24.9Scd,Hi db 0.000000 0.000000 0.243000 0.486000 4 Strobes Potter CS-24 Strobe,9Scd 0.000000 0.000000 0.220000 0.880000 Total Standby: 0.00000 Total Alarm: NAC 2 MAX Circuit Current(amps): 3 Source Voltage Used)VDC): 20.4 Usage:I J Description:(Cir.#2.Main Area Wire Type Ohms/1000ft Length 1•Way Actual Ohms Max Load(amps) Volts @ EOL Min Volts Req'd #14 Solid 2.5 300 1.500 1.389 18.32 16 Circuit Devices Standbt(amps) Alarm(amps) Qty Lookup Type Description Each Total Each Total 3 Strobes Potter CS-24 Strobe,9Scd 0.000000 0.000000 0.220000 0.660000 3 Horn Strobes Potter CHS-24.9Scd,Hi db 0.000000 0.000000 0.243000 0.729000 Total Standby: 0.00000 Total Alarm: NAC 3 MAX Circuit Current(amps): 3 Source Voltage Used(VDC): 20.4 Usage:(Notification I Description:ICirt.#3,Locker/Tanning Area (*1 Wire Type Ohms/1000ft Length 1-Way Actual Ohms Max Load lamps) Volts @ tOt Min Volts Req'd #14 Solid 2.5 400 2.000 0.689 19.02 16 _ Circuit Devices Standby(amps) Alarm(amps) City Lookup Type Description Each Total Each Total 13 Strobes Potter S-24 Strobe,SScd 0.000000 0.000000 0.042000 0.546000 1 Horn Strobes Potter CHS-24,30cd,Hi db 0.000000 0.000000 0.143000 0.143000 Total Standby: 0.00000 Total Alarm: 0.68900 Potter Electric Signal(C)2017 3 of S AFC-4000 Battery and Voltage Drop Calculation QDarrel. Ms SymDdol PtitlzRm NAC Circuit Configuration&Voltage Drop(cont'd) NAC 4 MAX Circuit Current(amps): 3 Source Voltage Used(VDC): 20.4 Usage:[Notification 1 Description: Circ.#4,Locker Room, Wire Type Ohms/1000ft Length 1-Way Actual Ohms Max Load(amps) Volts till EOL Min Volts Req'd #14 Solid 2.5 0.000 0.568 20.40 16 Circuit Devices Standby lamps) Alarm(amps) Qty lookup Type Description Each Total Each Total 2 Horn Strobes Potter CHS•24,30cd,Hi db 0.000000 0.000000 0.143000 0.286000 2 Strobes Potter CS-24 Strobe,30cd 0.000000 0.000000 0.120000 0.240000 1 Strobes Potter S-24 Strobe,l5cd 0.000000 0.000000 0.042000 0.042000 Total Standby: 0.00000 Total Alarm: 0.56800 NAC 5 MAX Circuit Current(amps): 3 Source Voltage Used(VDC): 20.4 Usage:'Unused Description:I 1 Wire Type Ohms/1000ft Length 1-Way Actual Ohms Max Load(amps) Volts @ EOL Min Volts Req'd #14 Solid 2.5 0.000 0.000 20.40 16 Circuit Devices Standby(amps) Alarm(amps) Qty Lookup Type Description Each Total Each Total Total Standby: 0.00000 Total Alarm: 0.00000 NAC 6 MAX Circuit Current(amps): 3 Source Voltage Used(VDC): 20.4 Usage:[Notification I Description:(outdoor H-S I Wire Type Ohms/1000ft Length 1-Way Actual Ohms Max Load(amps) Volts @ E01 Min Volts Req'd #16 Solid 4 100 0.800 0.140 20.29 16 Circuit Devices Standby lamps) Alarm(amps) Qty Lookup Type Description Each Total Each Total 1 Horn Strobes W-P,Potter WGEC24-75WR,HI db 0.000000 0.000000 0.140000 0.140000 Total Standby: 0.00000 Total Alarm: 0.14000 Potter Electric Signal(C)2017 4 of S AFC-4000 Battery and Voltage Drop Calculation P POTTER I/O Circuit Configuration& Voltage Drop Planet Fitness 12/18/2019 I/O 1 MAX Circuit Current(amps): 1 Source Voltage Used(VDC): 20.4 Usage:[Notification 1 Description: Cellular Monitor Wire Type Ohms/1000ft Length 1-Way Actual Ohms Max Load(amps) Volts®EOL Min Volts Req'd 818 Solid 6.4 20 0.256 0.000 20.40 16 Circuit Devices Standby(amps) Alarm(amps) Qty lookup Type Description Each Total Each Total 1 User Defined Dry Contact 0.000000 0.000000 0.000000 0.000000 Total Standby: 0.00000 Total Alarm: 0.00000 I/O 2 MAX Circuit Current(amps): 1 Source Voltage Used(VDC): 20.4 Usage:( 1 Description: J Wire Type Ohms/1000ft Length 1-Way Actual Ohms Max Load(amps) Volts @ EOL Mln Volts Req'd 818 Solid 6.4 30 0.384 0.000 20.40 16 Circuit Devices Standby(amps) Alarm(amps) Qty Lookup Type Description Each Total Each Total 1 User Defined Dry Contact 0.000000 0.000000 0.000000 0.000000 Total Standby: 0.00000 Total Alarm: 0.00000 Planet Fitness 12/18/2019 I/O 3 MAX Circuit Current(amps): 1 Source Voltage Used(VDC): 20.4 Usage:L____ 1 Description: Wire Type Ohnis/1000ft Length 1-Way Actual Ohms Max Load lamps) Volts®EOL Min Volts Req'd 814 Solid 2.5 0.000 0.000 20.40 16 Circuit Devices Standby(amps) Alarm(amps) Qty Lookup Type Description Earls Total Each Total Total Standby: 0.00000 Total Alarm: 0.00000 I/O 4 MAX Circuit Current(amps): 1 Source Voltage Used(VDC): 20,4 Usage:1 1 Description:[Emergency Comm Monitor J Wire Type Ohms/1000ft Length 1-Way Actual Ohms Max Load(amps) Volts®EOL Min Volts Req'd 814 Solid 2.5 80 0.400 0.000 20.40 16 Circuit Devices Standby(amps) Alarm(amps) Qty Lookup Type Description Each Total Each Total Tota Stan..y: 0.00000 Total Alarm: 0.00000 Potter Electric Signal(C)2017 5 of 5 AFC-4000 Battery and Voltage Drop Calculation . po 0 AF The Symbol of Protection Fire Alarm Control Panel Features r • 1,270addre avalableonthisanalogaddressablesystem • Additional system capacity achieved via multi-point SLC modules f • 1500 software zones - = NFPA 72 Compliant Smoke Sensitivity Test Built-In � low i,. AFC-1000, • System Operates as ClassA or Class B for SLC,P-Link and NACs ,'`t 1� i� - 10 Amp Power Supply,Expandable to 315 amps • 6 NA CS,Regulated,Rata!at 3 Amps each,expandable to 192 i, • 4 Input/Output(I/O)Circuits for system flexibility rated at I Amp each, ideal for manual release and abort = Strobe Synchronization and System Wide Sync for Geitex®, ' AMSECO®,Cooper Wheelock®and System Sensor®strobes • Dedicated Alarm,Supervisory and Trouble Relays i • 4,000 Event History Buffer • Optional two line DACT with UD-1000 that can report General,Zone or Point Information • I r , Built in IP communicator 4 • Ethernet Port for Programming and Network Connectivity • E-Mail System Status,Reports and Event Information • Product includes 5 year warranty NYC Fire Dept. ‘':-., Clill Certificate of Approval " '2 6256 -'E (LISTED 7165-0328:0509 S735 Description Technical Specifications The AFC-1000 is an expandable analog/addressable releasing fire Dimen§ons 1815/16"W x 27 5/1e°H x 4'/1e"D alarm system with a total system city of 1270 addresses Additional 5.0 Amps @ 120 VAC 50/60 HZ city on the system is achieved using multi-pant SLC modules AC Mans 3.OAmps@240 VAC 50/60 HZ The contra panel utilizes the exd usive Potter protocol that includes a complete to line of tensors and modules. The system is expandable with a End osure 16 gauge cold rolled steel with removable total of nine additional addressable Signaling Line Circuits(SLC) es41 locked door with Le<an viewing window with a maximum of 127 devices Each SLC may be compriseci of any Standby Current-130 mA combination of smoke sensor,heat detectors ors or modules aid allows for a Alarm Current-200 mA total of 50 ohms of impedance and may use any wire compliant with the ° 10 Amps National Electrical Code(NEC). Battery • 3Amps pa NAC,regulated ower for NACs, /O,and P-Link The AFC-1000 has a 10 Amp power supply with six Notification ° 1 Amp per I/O dreuit,regulated Appliance Circuits (NACs) and four Input/Output (I/O) circuits The ° Battery Charger range 8-55Ah NACs are rated at 3 Amps each and the I/Os are rated at 1 Amp each. • Batey Charger voltage 27.3 VDC • Each output is regulated and power limited. In addition, eadn output is P Link maximum current of 1 Amp uniquely programmable and may be configured for steady signal,strobe Temperature and 32°to 120°(0°C to 49°C)with a maximum synchronization, dant power, door holder power, or releasing. The Humidity Range humidity of 93%non-condensing. strobe synchronization indudes Gante;,AM SECO, System Sensor and CoopeRWheelodc and with the exdugve Quadrasync each output may have a unique brand and all strobes will flash together. The NACs may bee goanded using the PSN-1000 seri es i ntel I i gait power supplies Each PSN-1000 adds another 10 Amps of power,2 additional input drouitsaid theAFC-1000 will support upto31 power supplies The system will synchronize the strobes system wide. In addition, the PSN- 1000E hasspaaeto al low the instal I ati on of up to six PAD 100-SLCE SLC loop expansion cads The cads mount on a sad<er bracket that allows axessto all SLC circuit connections -- ------- - ---- ------ — — ---- - -- --------- -- Potter Electric Signal Company, LLC ° St. Louis, MO ° Phone: 800-325-3936 ° www.pottersignal.com 8830135-REV B = 01/18 PAGE 1 OF 4 : ,. 0 A The Symbol of Protection Fire Alarm Control Panel SLC Loop Accessories The control panel may be connected with up to 1,270 addressable devices or modules in any combination.The SLC is not restricted by any special wire requi rements and may be wi red with any wire that complies with the NEC. SLC Loop Devices Device Description FAD100-PD Analog Photo Electric Smoke Detector is a smoke detector with a listed obscuration of 1.02 to 3.83 percent per foot. PAD100 PND Combi nation Analog Photo Electric Smoke'He t Detector—a smoke detector with a listed obscuration of 1.02 to 3.83 percent obscuration and a fixed temperature 135°Fahrenheit heat detector. FAD100-HD Analog Fixed(135d-185dF)or Rate-of-Rise Heat Detector(software selectable) FAD100 DUCTR Addressable Duct Smoke Detector with Form C Relay.Addressable Duct Smoke Detector with Form C relay rated at 10a @ 250/120VAC or 8amps at 30VDC. FAD100-DUCT Addressable Duct Smoke Detector. FAD100-6B 6" round base that is mounted to an electrical box and wired for connection of one of the above sensors. PA D100-4B 4" round base that may be mounted to an electrical box and wired for connection to the above sensors. FAD100-I B Isolator base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop. FAD100-RB Addressabte Relay Base that contains one relay controlled by the SLC.Relay is rated at rated at 2 amps at 30 VDC or 0.5A at 125VAC. PAD100-SB Addressable Sounder Base that contains an addressable sounder module that may be configured for local,group and all call. FAD100-CD Addressable CO gas detector. FAD100-DD Addressable photo electric smoke detector for use in DUCT/DUCTRenclosure. Modules Device Description PA D100-MIM Micro Input Module provides a small foot print contact module for mounting inside an enclosure. PAD100-PSSA SingleActionAddressableRill Station. FAD100-PSDA Dual Action Addressable Pull Station. FAD100-SIM Single Input Module is a standard contact module with an LED that mounts into a 4" square electrical box. PAD100-DIM Dual Input Module is a device that can monitor two distinct inputs with a single device or in aClassAmode PAD100 TRTI Two Relay Two Input module provides two form C relays that are individually controlled by the control panel.Each relay is rated for 2 amps at 30VDC or 0.5 amps at 125VAC.Also provides two contact inputs. PAD100-NAC Notification Appliance Circuit module is an addressable remote appliance circuit controlled by the panel. PAD100-ZM Zone Module is used to connect conventional 2-wire smoke detectors to the system PAD100-I M Module interrupts a short on the SLC and prevents the short from affecting protected devices on the loop. FAD100-RM Relay Module that provides one form C relay controlled by the control panel.Relay is rated for 2 amps at 30VDC or 0.5 amps at 125VAC. PAD100-LED Module provi des a single addressable LED that is controlled by the control panel. FAD100-SM Speaker Module provides switching for two audio channels. FAD100LEDK Addressable LED and key switch that mounts in asingle gang box. FAD100-DRTS DUCTR Remote Test Switch that mounts in a single gang box and optionally supervise!.For use with the FAD100-DUCTR only. FAD100-0R01 One Relay One Input Module provides one form C relay and one input.The relay is rated at 2 amps at 30VDC or 0.5 amps at 125VAC. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830135-REV 8 • 01/18 PAGE2OF4 0 , ',, ,. i i AFC-1000 u, The Symbol of Protection Fire Alarm control Panel SLC Features -60758-2x16LCD annundatorwith akey pad inalocked The Potter protocol isa digital protocol with a proven design for metal enclosure. reliability aid noise immunity,The system does not requi re special RA-6500R(F)—4 x 40 LCD annund ator with a key pad in a locked cabl e or conductors for connection of the Signaling Line Circuit metal enclosure.Flush mount version available. as long as the cable i s comp)i ant with N FPA 70 and NFPA 72. LED-16(F)—16 LED annunciator with common indicators i n a The system allows for Cl ass A or Class B installations as well as locked metal enclosure. Flush mount version ava l able "T Tis."Each loop is caoabl e of 127 points,with a max wiring PSN-1000(E)—10 amp,remote intelligent power supply with di stance of 10,000 ft. 6 NACs,2 I/Os and a P-Link repeater.This panel is listed in conjunction with theAFC-1000 as releasing d rcui is Sensor Features CA-6500—ClassA convertor that converts the SLC, NACsand The sensors through the fire alarm control panel provide a real P-Link connection time status as to the condition of the system.The smoke detector UD-1000—UL listed, Duel line telephone alarm communicator sensitivity, heat detector temperature level and drift compensation DRV-50—LED driver expander,used to connect up to 50 LEDs in a are all programmable options The system also allows for a day/night graphic display mode where the panel automati at I y adjusts the sensitivity depending FCB-1000—Fire communication bridge,provides remote mounting on the time of day.To assist in the reduction of false alarms,the of the Ethernet connection smoke detectors also have a mel ntenance warn ng that sends a trouble F113-1000—Fi ber interface module,used to extend RL i nk to mud ti signal when a detector i s di rty to the point that it can no longer maintain the programmed sensitivity. mode fiber(2 required) RLY-5—Relay module,provides 5 form C relay contacts rated at 3.0 User Interface amps24VDC/125AC The fire alarm control panel has a 4 x 40 LCD display to provide SPG-1000—Serial parallel gateway,al l ows for the connection to a information to the system status The keypad has navigation keys Vial or parallel printer to allow manipulation of the Menu on board the panel.The panel is The Ft B-1000,FCB-1000 aid the SPG-1000 may be i nstall ed in the shipped standard with the following LEDs stacker bracket or ordered with the optional rack mount enclosure. • AC Power Greer MC-1000 Multi-Connect allows up to sixty-threeAFC series panels • A I arm Red to share a singl e reporting technology. • Earth Fault-Amber AE-2—Two card expansion cabinet - Supervisory-Amber AE-8—Eight card expansion cabinet - Silenced-Amber AE-14—Fourteen cad expansion cabinet • Trouble-Amber • Pre-Release-Amber Ethernet/I.P. Connection - Rd ease-Red TheAFC-1000 is shipped standard with an Ethernet connection. The common buttons i nd ude a Silence, Reset,Acknowledge,and This connection i s the programming port and may be connected Drill.All of the buttons are aeessi bl a once the locked door is to a building Wide Area Network(WAN)or Local Area Network fie. (LAN). Once connected to the Internet,the panel may be selecti vely programmed to e-ma I dam conditions,trouble conditions, P-Link supervisory conditions,test,Event History and detector status An TheAFC-1000 has a proprietary communication protocol that e-mail may be sett to the panel and the wet will e-mail the event communicates through a RS-485 connection to field devices.Up history,detector status,configuration file or server status to an to 64 devices may be connected to a single P-Link connection.The authorized E-mail account. In addition,recti nders may beset to send P-Link i nd udes the communication terminals and regulated 24 VDC an email for service,testing or other conditions connection for the field devices.The field devices may be any of the In addition,the Ethernet connection is UL listed asap IP following: communicator.The I P communicator is listed to report to the UL PAD100SLCE-A nal og/Addressable loop expansion module listed Sur-Gard III IP receiver.The I P communi Gator replaces the (maximum of 9 per AFC-1000) traditional less reliable dam communicator transmitter that utilized SLCE-127-Nohmi addressable loop expansion module for retrofit telephone I i nes.The I P communicator i s an active method of applications connection and communication to the monitoring station. Potter Electric Signal Company, LLC - St. Louis, MO Phone: 800-325-3936 - www.pottersignal.com 8830135-REV B ° 01/18 PAGE 3 OF 4 _ _ pol ,,,, ER AFC1000 The Symbol of Protection FireAlarm Control Panel Dimensilms 18.91" 17.60" 0 0 1- LPC) . ca. 4.41" .1. 3.75" — EFCU 0 : 0 e e 0 0 . . 1 0 0 I,. I Cs1 9 ( 1 , 1 0 : CD L 0 . , 0 ! 1.. . , 1 I ....._,.. AFGUT,EF Si-II UT.EF L 1 ‘, . CPULPN 0 Ordering information Model Description 1 Stock No. 1 AFC-1000 Fi re A I arm Control Panel 3992754 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830135-REV B . 01/18 A4GE 4 OF 4 parroz The Symbol of Protection LCD ANNI T',CIATOR I NSTALLAT ON Features ii r Standby Current 20 mA 11 6 Alarm Current 25 mA yb ^' �� t ;' Operating Temperature 0°C-49°C(32°F-120°F)10%-93% I �T ' ii ,,;,r I @ 30°C(86°F)non-condensing h r ,'',44' ' humidity rl �, r l�'", ? Maximum Wire Length 6500 FTy� r � • • Maximum Annunciators 31 ? , f Size(WxHxD) 8"x 6-1/4"x 1-5/8" Wire Gauge 14 AWG-22 AWG i:� : ,,��. — ' x,+ ., . ��� t 0 * LISTED P S2930 7165-0328:0195 Description i nstailation The RA-6075 is a LCD remote annunciator for the PFC-6075 and The RA-6075 is connected to the PFC-6075 using a four wire RS-485 PFC-6030 addressable fire control panel.The RA-6075 communicates connection.The connection is power limited and supervised.Up to using a RS-485 connection to the main panel providing common thirty-one(31)RA-6075 LCD annunciators can be connected using indication of Alarms,Supervisory,Trouble and other system status and Class B or Class A wiring.Class A wiring requires an optional CA- control functions. 6075 Class A Expander. The RA-6075 features a 16x2 LCD display with LED's for Power, Alarm,Supervisory,Trouble,and Silenced conditions.It can be mounted on a single gang electrical box or a two square electrical box. The annunciator is enclosed in a sheet metal enclosure and has a Potter Install in accordance with installation manual,#5403593. lock securing the keypad. Figure 1:RA-6075 Class B Wiring Example I Figure 2:RA-6075 Class A Wiring Example I To the next annunciator i F E -] F I �� ' 1 m a e ice, , �i 6 CA-6075 \ m \ A l_T�r V �.1 'Connection r i ^ , ¢ i 4P-LINK L. V w \ _� I A 13 V SI f Panel �{ 3 j I l: t �� ', t- . L € i l 'I. Panel-' Conection i \[O' i I"C6 \ RemAnnunator -LIN S .. A p I i A Annunciator I \,I N : LNj.. E.-+)---. .0 : Nil Remote + Remote Annunciator I Annunciator Potter Electric Signal Company,LLC•St.Louis,MO•Cust Service:866-956-1211•Tech Support:866-240-1870•Canada:888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#5406077-REV B PAGE 1 OF 2 9/11 0 x . The Symbol of Protection LCD ANNUNCIATOR INSTALLATION Address Settings The RA-6075 address is set by dip switch Si located on the back of the RA-6075.The address must be set in the range of 1 to 31 to be recognized by the control panel. Figure 3:RA-6075 Class A(back panel view) Ilera 0 0p p NIMH \\. OJ O +, a lin C- OE§) ° / O 0 Dip Switch Settings Refer to the table below for dip switch settings per Annunciator Address. Annunciator Dip Switch Settings Annunciator Dip Switch Settings Address SW-1 SW-2 SW-3 SW-4 SW-5 Address SW-1 SW-2 SW-3 SW-4 SW-5 1 On Off Off Off Off 17 On Off Off Off On 2 Off On Off Off Off 18 Off On Off Off On 3 On On Off Off Off 19 On On Off Off On 4 Off Off On Off Off 20 Off Off On Off On 5 On Off On Off Off 21 On Off On Off On 6 Off On On Off Off 22 Off On On Off On 7 On On On Off Off 23 On On On Off On 8 Off Off Off On Off 24 Off Off Off On On 9 On Off Off• On Off 25 On Off Off On On 10 Off On Off On Off 26 Off On Off On On 11 On On Off On Off 27 On On Off On On 12 Off Off On On Off 28 Off Off On On On 13 On Off On On Off 29 On Off On On On 14 Off On On On Off 30 Off On On On On 15 On On On On Off 31 On On On On On 16 Off Off Off Off On PRINTED I N USA MFG.#5406077-REV B RAGE 2 OF 2 9/11 POTTER Addressable Pull Station The Symbol of Protection Single/Dual Action F-atures Single or Dual Action versions o-r,x, ..r•i"�i.e�'" CJS �y.„'• d.�'K ° Durabledie cast construction G . . i, , ''T Reset key matches the fire alarm control panels 4 �p� �( 'i LAR', l Compatible with IPA&ries panels ; SLCCIassA, Class & Class B ; ,g5 � }uY 5 .Product ind udes a 5 yeawarranty , ). +• z . iI) •lsi R ` 3 d t1t;ur i xa� ' ^ tis ' F•' s ; ” J', : 'i .'e.4:, ' t + W � 1•V',. � ''�{' 1• I r t 1 , dThd (Y.'\ .TTERTEr' .A n � ^A t , Description Technical Specifications The PAD100-PSSA (Single Action) is activated by simply pulling Operating Voltage 24.0 VDC the white°T" bar handle down. The PAD100-PSDA (Dud Action) is activated by lifting the front cover and then pulling the white"T" Max SLC Standby Current 200uA bar handle down. Once activated,the°T" bar cannot be reset without Max SLC Alarm Current 200uA opening the front cover. Opening the front cover will also activate the 32°F-120°F(0°-49°C) pull station.To reset the PAD 100-PS Series, use the Potter WS-93 key Environmental Limitations Indoor Only to unlock and open the front cover. Once the cover is open, push the "T" bar back into the norms position and re-stere the front cave- Dimensions _ 4.75" H x 3.25" Wx 1.75" D Relative Humidity Range 0-93%(non-condensing) Application Single gang box or The PAD100-PSSA/PSDA is compatible with Potter's IPA and AFC/ Mounting Options Potter P32-BB/DBB ARC series addressable fire alarm control panels. It is a non-coded APS SA-1.22 lbs addressable pull station avai l abi e in either a single or dualaction Shipping We i ght APS-DA 1.461 bs model and i nstal I s on a single gang box or sarf�mounts using the P32-BB or P32-DBB(dam)back box. Potter Electric Signal Company, LLC ° St. Louis, MO ° Phone: 800-325-3936 • www.pottersignal.com 8830097-REV C ° 3/18 PAGE 1 OF 2 PAD100- SS A Addressable Pull Station The Symbol of Protection Single/Dual Action Setting the Address The PAD100-PS Series uses one SLC address assigned to the device. The address is set using the DIP switch located on the back of the PAD100-PS device Pull Station Front View Fig 9 A "1'-a, , g PIIRE DA[ARm I '!!'j oOW Illi 4 ( 0a417 eporrtg OPar PAD100-PSDA PAD 100-PSSA Pull Station Back View and Wring Fig 2 loormir •PoorrrEEE _ tt 1 a, • 1101Y hIl CBPPSZDCSFE!mOIBW- i 4:B'N ICBOOPS! C6RAPV17ERADF LP!OFYUEFACF! Ordering information Mom Descr Stock Na PAD100-PSSA Addressable Pull Station, SingleAction 3992721 PAD100-PSDA AddreEseble Pull Station, Dual Action 3992720 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830097-REVC • 3/18 PAGE2OF2 pA Di 00.p D The Symbol of Protection Photoelectric Smoke Sensor Features Low profile,less than 2 inches with the base : • Wide selectable sensitivity range of 1.0 to 3.7%/foot Ca • Sensor communicates sensitivity to control panel ▪ UL listed smoke calibration and sensitivity • Optional locking tab to prevent unwanted removal • Simple DIP switch address setting,no programming tool required • LED alarm indicator • Product includes a 5 year warranty LISTED escriptaon Technical Specifications The Photoelectric Smoke Sensori s a l i sted Anal og Addressable smoke Operating Voltage 24 VDC sensor compatible with fire alarm control panels that utilize the Potter Addressable Device(PAD)protocol.The PAD100-PD is a low profile Detector Current Draw 300 p.A smoke sensor with a wide sensitivity range.The sensor and base(not Alarm indicator 1 LED included)are made of a durable plastic in an off-white color to blend Alarm set-point range 1.0 to 3.7%/ft 3.6-12%/m in with the ceiling. Installation temperature The PAD100-PD has a sensitivity range of 1.0 to 3.7 %per foot andrange 32 to 120°F/ 0 to 49°C is UL. The PAD100-PD features drift compensation and has built in dirty detector warning as well as. The PAD100-PD and the control Oper2ki ng relative 0%to 93%(Non-condensing) panel communicate over a proven and robust digital communication humidity range path and the system analyzes the information at the particular device. Start-up time Max. 1 sec. The total polling speed is less than five(5)seconds,well under the UL Maximum number of requirements. addresses per loop 127 The sensor is compatible with any of the PAD series sensor bases and Maximum number of simply twists on. The PAD100-PD is addressed using DIP switches lighted indicators in 30 in the rear of the sensor and can be easily programmed in the field elan per loop. without special tools. Color Eggshell White Setting the Address Weight(without base) 101g(3.56oz) Each addressable device on the SLC loop must have a unique address Dimensions(without Height: 1.35 in(34mm) from I to 127 to function properly. The address is set using DIP base) Diameter:3.93 in(100 mm) switches. Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to SLC or device. Verify the following: 1. Power to the device is removed 2. Field wiring is correctly i nsta l ed. 3. Field wiring has no open or short circuits. Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830108-REV C 3/18 PAGE 1 OF 2 The Symbol of Protection Photoelectric Smoke Sensor Air Velocity Ratinks The PAD100-PD has an Open Area of Protection air velocity rating of 0 to 300 feet per minute. The system has a maximum of 30 LEDs that can be turned on simultaneously.If the system already has 30 LEDs on,the PAD 100-PD will operate even though the LED may not illuminate. Operation The PAD100-PD is an analog addressable sensor that uses one address on the Signaling Line Circuit(SLC)of a compatible fire alarm control panel. The unit communicates with the control panel as it is polled.The LEDs flash every time the unit is polled and they will flash at a fast rate if the unit is in an active status.The polling LED can be turned off if desired for less conspicuous operation. The PAD100-PD with the PAD100-4DB or PAD100-6DB has a low profile of less than two(2)inches to blend into the surrounding environment.The sensor includes an insect screen to prevent foreign objects from reaching the chamber and the can be cleaned to restore operation of a dirty detector. Sensor Sensitivity The PAD100-PD and the compatible control panel work in tandem to keep the sensitivity consistent.As the sensor is installed over time,the sensor compensates for the dirt in the unit until it is out of range.At that time,the panel will indicate a dirty sensor.The sensor will then have to be cleaned or replaced. The PADI00-PD can be programmed to provide a maintenance alert prior to reaching the dirty sensor level which will allow for mten ation prior to the sensor going into trouble. This allows for sensor replacement or cleaning prior to a nuisance trouble occurs. )71 :As required by NFPA,do not install the sensors until all construction is complete and the work area has been thoroughly cleaned.If the sensors have been installed in a construction environment,they should be cleaned or replaced before the system is placed into service. Spacing The PAD 100-PD is UL listed with a recommended maximum spacing of 30 feet.Refer to NFPA 72 for specific information regarding detector spacing, placement and special applications. Compatible Bases All bases will mount on a single gang,double gang,octagon,4"square or mud ring electrical box. Device Description Stock No. PAD100-4DB 4"Standard Base 3992731 PAD100-6DB 6"Standard Base 3992732 PAD 100-1B 6"base with an isolator module included. 3992730 PAD 100-RB 6"base with one Form-C relay contact. 2A @ 30VDC,0.5A @ 125VAC 3992728 PAD100-SB 6"base with sounder module included.Sound pattern is provided from external source. 3992729 PAD100-SPKB 6"base with speaker included 3992762 Ordering Information Madel Description Stock No. F D100-PD Photoelectric Smoke Sensor 3992733 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830108-REV C ° 3/18 PAGE 2 OF 2 ' POTTER F, , 0100,...HD The Symbol of Protection Heat Detector Features • Selectable Rate of Rise and/or Fixed Heat Detector • Low profile • Reliable detection technology • LED Alarm Indicator • Ambient temperature listing of 32°F to 150°F • Simple DIP switch address setting,no programming tool required • Product includes a 5 year warranty ai.:i;11,:.;...:,..), ID LISTED Description Technical Specifications The PAD100-HD is a listed Analog Addressable rate of rise and/or Operating Voltage 24 VDC fixed temperature heat sensor compatible with any fire alarm control -�-- panel that has the Potter Addressable Device(PAD)protocol.The heat Detector Current Draw 300µA sensing portion utilizes a proven thermistor for accurate and reliable Alarm indicator 1 LED heat detection. The sensor and base (not included) are made of a Alarm set-point range 135 to 185°F/57 to 85°C durable plastic in an off white to blend in with the ceiling. Installation temperature The PAD100-HD is UL listed with a selectable fixed temperaturerange - 32 to 150°F/ 0 to 66°C point from 135° to 185° Fahrenheit and can be used for rate of rise Operating relative applications. See detector spacing limitations below. This flexibility 0%to 93% (Non-condensing)humidity range allows the installer to cover a wide variety of applications with a single unit. Start-up time Max. 1 sec. The PAD100-HD and the control panel communicate over a proven Maximum number of 127 and robust digital communication path and the system analyzes the addresses per loop information at the particular device.The total polling speed is less than Maximum number of five(5)seconds,well under the UL requirements. lighted indicators in 30 The sensor is compatible with any of the PAD series sensor bases and alarm per loop simply twists on. The PAD100-HD is addressed using DIP switches Color Eggshell White in the rear of the sensor and can be easily programmed in the field without special tools. Weight(without base) 82g(2.89 oz) Dimensions(without Height: 1.94 in(49mm) Setting the Address base) Diameter 3.93 in(100mm) Each addressable device on the SLC loop must have a unique address from 1 to 127 to function properly. The address is set using DIP switches. Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to SLC or device.Verify the following: 1. Power to the device is removed 2. Field wiring is correctly installed. 3. Field wiring has no open or short circuits. Potter Electric Signal Company, LLC - St. Louis, MO - Phone: 800-325-3936 • www.pottersignal.com 8830110-REV C • 3/18 PAGE 1OF2 i0 The Symbol of Protection Heat Detector Operation The PAD100-HD is an analog addressable sensor that uses one address on the Signaling Line Circuit(SLC)of a compatible fire alarm control panel. The unit communicates with the control panel as it is polled.The LED flashes every time the unit is polled and will flash at a fast rate if the unit is in an active status.The polling LED can be turned off if desired for Iess conspicuous operation. The PAD100-HD with the PAD100-4DB or PADI00-6DB has a low profile to blend into the surrounding environment.The system has a maximum of 30 LEDs that can be turned on simultaneously.If the system already has 30 LEDs on,the PAD100-HD will operate even though the LED will not illuminate. Spacing The ANSI/UL listed spacing limitations of PADl 00-HD smooth ceiling are dependent on alarm set point. Alarm Set-Print Rate of Rise Spacing Fixed Temperature Spacing 135°F to 160°F Max.70 ft. Max.70 ft. (57°C to 7I°C) 161°F to 174°F Max.60 ft. Max.60 ft. (72°C to 79°C) 175°F to 185°F Max. 15 ft. Max. 15 ft. (80°C to 85°C) Compatible Bases All bases will mount on a single gang,double gang,octagon,4"square or mud ring electrical box. Device Description Stock No. PAD100-4DB 4"Standard Base 3992731 PAD100-6DB 6"Standard Base 3992732 PADI00-IB 6"base with an isolator module included. 3992730 PAD100-RB 6"base with one Form-C relay contact. 2A @ 30VDC,0.5A @ 125VAC 3992728 PADI00-SB 6"base with sounder module included. Sound pattern is provided from external source. 3992729 PAD100-SPKB 6"base with speaker included 3992762 Ordering information lin odel Description Stock No. PAD100-HD Fixed Temperature Heat Sensor 3992735 Potter Electric Signal Company, LLC o St. Louis, MO a Phone: 800-325-3936 www.pottersignal.corn 8830110-REV C o 3/18 PAGE2OF2 : : f) 0 PAD100-SIM The Symbol of Protection Single Input Module Features • One(1)Class B monitoring input SLC ClassA, ClassX & Class B Mounts in a standard 4" or double gang box ® Wring termi nals accessi bl e when mounted in box • All wiring termi nal s accept 22 to 12 AWG . Product I nd udes a 5 year warranty , f;o i ula This addressable module does not support 2-wire smoke detectors Description Technical Specifications The PAD 100-SIM uses one(1)SLC loop addresses when monitoring Operating Voltage 24.0V one(1) Class B circuit. The module mounts on either a 4" square or double gang box.The module is capable of monitoring one(1) Class C ax C Standby 240µA ent B circuit. The PAD100-SIM includes one red LED to indicate the module's status.I.n normal condition,the LED flashes when the device Max SLC Alam 240µA is being polled by the control panel. When the input is activated, the Current LED will flash at a fast rate. Max Wring Resistare 100 S2 of IDC Application MaxWarjng 1 F Capacitance of IDC µ The PAD100-SIM is compatible with Potter's IF aid AFC/ARC series addressable fire alarm control panels. The PAD100-SIM is an EOL Resistor 5.1K S2 interface module used to monitor dry contact devices such as sprinkler Operating Temperature 32 to 120°F(0 to 49°C) Range waterflow, valve tamper switches, or conventional pull stations. The module is capable a of monitoring one Class B circuit. RO ge ng Humidity 0 to 93%(non-condensing) Setting the Address Max no.ofModulePer 127units Each addressable SLC device must be assigned an address.The address Loop is set us ng the DIP switch located on the PAD100-SIM. Dim ons 4.17' (106mm)L x 4.17' Before connecting a device to the SLC loop, take the following (106mm)W x 1.14" (29mm)D precautions to prevent potential damage to the panel or device: Mounting Options Standard 4" Square or 1. Power to the device is removed. Double Gang Box 2. Field wiring iscorrectly installed. Shipping Weight 0.6 lbs 3. Field wi ri ng has no open or short circui is Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 " www.pottersignal.com 8830083-REV C ^ 3118 PAGE 1 OF 2 The Symbol of Protection Single Input Module Installation Using C ,mpatibie Electrical Box Fig 1 O O O ' O •i'1 -... Wiring Diagram PAD90OS1 M Wtia ClassB Circuit Fig 2 I 420D o____ O GSP N!C 3DCIPS! " " C PVT1NPEVl1ff \ G VtiI I'�;1'I39 .. lP!OFYUNPEVA� .1:312sicJJ' I m ,.' 1 4 d 1 O A`If PCE.PGMDF!SFT,1ftPS 111 T T o ° 1 6/2!_!PI N! %X ani$4116124 0 P \ r O (:::) g O f-. '1 Ordering Information model Description Stock No. PAD 100-SIM Si ngi e Input Module 3992704 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830083-REV C • 3/18 PAGE 2 OF 2 POTTER PAD100-D1M The Symbol of Protection Dual input Module Features • Single module with dud contact monitoring inputs • Two(2)Class B or one(1)ClassA monitoring inputs • SLC CIaA,ClassX& Class B • Mounts in a standard 4" or double gang box • Wiring terminals accessible when mounted in box • All wiring terminals accept 22 to 12 AWG r,unTru • Product includes a 5 year warranty CAUTION Thi s addressable module does not support 2-wire spoke detectors. O U L `. Description Technical Specifications The PAD 100-DIM ups one(1) SLC loop address when monitoring Operating Voltage 24.0V two(2)Class B a rcui is or one(1)CI assA d rcui t.The module mounts on either a 4" square or double gang box. The module is gable Max �x C Standby 240µA Currof monitoring two (2) separate dass B d rcui is making it ideal for monitoring sprinkler waterflow and valve tamper switches when they Max SLC Alarm 240µA are located in the same proximity.The PAD100-DIM includes one red Current LED to indicate the module's status In norma condition, the LED Max Wiring Resistance 1000 flashes when the device is being polled by the control panel.When an Of IDC input is activated,the LED will flash at a fast rate. Max Wiring 14F Capacitaiceof IDC µ Application EOL Resistor 5.1K52 The PAD100-DIM is compatible with Potter's IPA aid AFC/ARC Operating Temperature 32 to 120°F(0to49°C) series addressable fire alarm control panels. The PAD100-DIM is an Range interface module used to monitor dry contact devices such as sprinkler Operating Humidity 0 to 93%(non-condensing) waterflow, valve tamper switches, or conventional pull stations. The e module is capable of monitoring two separate Class B or one Cl ass A Mac no.of Module Per 127 units circuits. Loop Setting the Address Dimensions 4.17 (106mm)LX4.17' (106mm)W x 1.14"(29mm)D Each addressable SLC device must be assigned an address. The Standard 4" Square or address is set using the DIP switch located on the PAD100-DIM.When Mounting Options DoublaGang Box the PAD100-DIM is used to monitor two individual Class B circuits a single device address is assigned, each input is then identified as a Shipping Weight 0.61b5 sub-point of the module address. For example, if the address number is assigned as "8", the first input will be"8.1"and the second input will be"8.2". Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to the panel or device: 1. Power to the device is removed. 2. Field wiring is correctly installed. 3. Fi d d wi ri ng has no open or short d rcui is Potter Electric Signal Company, LLC a St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830082-REV C ' 3/18 PAGE 1 OF 2 °TIER P A Di 00-DIM The Symbol of Protection Dual Input Module i; StaUation Using Co mpatibie Electrical Bix Fig a ,I,E 11,11 0 .I O .. O `..r ��. Wiring Diagrams PAD900-DIM Wer One ClaA Circuit Fig 2 NPVTLI F OVIDIEJITXJDI LP4-VQICPTJ.IPO Q EP SIDEMEN,SDH GEFIAPVT!NPEVA6 77:71- '11%111¶_LP!OFYUNPEVAF \ 13'" -ss-ic i Ni --BIW c CD D C OPLF FOE.PGIVIDFISFTJTIPS n JI"!OPLISMV.5E PADW0431 M Wth Two CiassB Circuits Fig NPVF!U F1 omenE,OTX.LO l LPh"EPXOi(PTJJPO CPPN KBDC]PS! z..« `�/ CT�VIPVT!NPEV1W \ U LP!CFYUNPEVAP \ 741 \ FO F SFTJTLPSJRPS 62L!PI N%X 11:1 Rt2 Coat$4116124 42] ° Lunmmi' IZ ° —CD (.9 FCE.PGIVEP SFTJRTPS 62L!PI N 95 O J$4116124 Ordering information Model Description Std No. PAD 100-DIM Dual Input M odul e 3992703 Potter Electric Signal Company, LLC o St. Louis, MO • Phone: 800-325-3936 o www.pottersignal.com 8830082-REVC 3118 P14GE2OF2 PAD100-RM The Symbol of Protection Relay Module Features • One(1)Form C relay contact • SLC ClaesA,ClessK&Class B • Mounts in a standard 4" or double gang box • Wiring terminals accessible when mounted in box • All wiring terminals accept 22 to 12 AWG • Product includes a 5 year warranty POTTER ceunoi� ,s ('( t.0l UL ; Description Technical Specifications The RAD100-RM uses one(1) SLC loop address to provide one(1) ' Form C relay contact. The module mounts on ether a 4" square or Operating Voltage 24.OV double gang box.The PAD 100-RM includes one red LED to indicate Max SLC Standby 240µA the module's status. In normal condition, the LED flashes when the Current device is being polled by the control panel. MaxSLCAiam 240µA Current AppiicatiOn Relay Contads 2A@30VDC,0.5A@125VAC The PAD 100-RM is compatible with Potter's IPA and AFC/ARC RO�e i g Temperature 32 to 120°F(0 to 49°C) series addressable fire alarm control panels. The PAD100-RM is an interface module providing one(1)Form C relay contact. Operating Humidity 0 to 93%(non-condensing) Range Setting the Address Max no.of Module Per 127units Each aidressel le SLC device mu/ be assigned an address. The Loop address is set using the DIP switch located on the PAD100-RM. The 4.17" (106mm)L x 4.17" PAD100-RM uses a single device address to identify relay contacts. Dimensions (106mm)W x 1.14" (29mm)D Before connecting a device to the SLC loop, take the following Mounting Options Standard 4" Square or precauti ons to prevent potential damage to the panel or device Double Gang Box 1. Power to the device is removed. Shipping Wel ght 0.6 I bs 2. Field wiring is correctly installed. 3. Field wiring has no open or short circuits. Potter Electric Signal Company, LLC ° St. Louis, MO ° Phone: 800-325-3936 ° www.pottersignal.com 8830084-REV C 3/18 PAGE 1 OF 2 ,.. ..., ,. P OTT ' - -' PAP 10' Illi L The Symbol of Protection Relay Module Installafioln Using C mpatible Electrical Box Fig 1 I(i:,: ��0." , _ 0 t... r,---- �, 0.„,...___ _0 '-it,k '1- B1 ox0 i 0 0 oo.44,..44,...,0..1 __s, i,l �- . i4 � 0 � - 7-2 rani ltisalligii Wiring Diagram PAD900-RM Relay Circuit Fig 2 f — 9 CEP N1C$DCIPS! }, " 4.._ '.,- C5FVIPVP.NPEV(E P. i"=l'Mill N •u1 --1 Na 4 ,. tPIOFYUNPEVI �a — Stc ��� of wxc r POF7)2*!CPSPIID ` IA SFEIDP°LEDUC O e L NCLLI O O O O IO O O O O J ,_, c. ® U NOTICE It is possible that the internal relay in the PAD100-RM may be shipped in the non-normal/activated state.To ensure that the internal relay is set to the normal state,connect the module to the SLC loop and reset the control panel before terminating the wiring to the modules output. Ordering Information WI odd Description Stock Na PAD 100-RM Relay Module 3992705 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830084-REV C a 3/18 PAGE 2 OF 2 ^x+l • •$'+x�7,�t'+r�.:„F;.,,�.,,;`;s,�S'�„%�FF,"t#r-a ate�X.e.•x•,.�'i`fi4rk'.SJri':M1.�:.�«"aif�d uai�`",I,s7i^ydNwh,:tY.fi{.7e'.,a`t k»4�'4x.,..,r}t�w,,::':id'r}*J•x)Ey,Jg'S"{^s'i#.i4'<:w.'r��'r ie�t27.I�rrUl4rr.r+.,,:.S.1.;s::,r-,..1:"I'�41J{E T�,N-f'�}irJ.a..�.wY'..'a-.i1'k'')k".i. 4r 11,444,4: kjpr frx p..5 Yr ”r1 r} r�,'rt_•;^hfx ( r9}/41,' iz is!`f, ' , x ✓ 1 � j ' (, ;(n • N ' . •r.41 ",:'',',i 7' 04L :•44 ' '''. ,'5"!30 � 9 l,wrSµatp� .%.4> a 1 „r"' j . I 4,4-414,$, y n f ',k . 1, •'Ity , :" 7Y, ,, 4 , a i„; „.Px , , pi. 7 i bFL�IM1, b:t . , ty ry Fx ..'r..,,:. Commander3 Series Selectable GEC3/GES3 Candela Evacuation Signals 12 & VDC Applications The Commander3 Series is a low profile strobe and horn/strobe combination SERIES that offers dependable audible and visual alarms and the absolute lowest current available. The GE3 Series 24VDC offers tamperproof field selectable candela options of `'► i' 15, 30, 60, 75, and 110 candela. The 12VDC offers tamperproof field selectable candela options of 15, 30, 60, and 75 candela. ( f` , The Commander3 Series horn offers a continuous or synchable temporal three t� r 1.1 dt; f yzly in 2400Hz and mechanical tone, a chime and whoop tone. All tones are easy r tty for the professional to change in the field by the use of switches. The GE3 Series has a minimal operating current and has a minimum flash rate of 1Hz regardless of input voltage. .roduct Listings The Commander3 Series is shipped with a standard 4” metal mounting plate 61GNALIMG which incorporates the popular Super-Slide®feature that allows the installer to easily test for supervision.The product also features a locking mechanism ` U (01 which secures the product to the bracket without any screws showing. ®` °' The Commander3 also features the patented Checkmate®- Instant Voltage LISTED I"`` "'( Verification feature which allows the installer to check the voltage drop draw ANSI/UL 464&ANSI/UL 1971 Listed and match it to the blueprint. a CSFM: 7135-0569:122(GEC3-24& The GE3 Series appliances are ANSI/UL 464 and ANSI/UL 1971, listed for use GEH-24) with fire protective systems and are warranted for three years from date of 7125-0569:123(GES3-24) purchase. 7125-0569:129(GES3-12) 7135-0569:130(GEC3-12& Standard Features GEH-12) • Nominal voltage 12VDC and 24VDC ° MEA: 285-91-E(GEC3-24&GES3-24) • 24VDC units have field selectable candela options of 15, 30, 60, 75& 110 580-06-E(GEC3-12&GES3-12) o 12VDC units have field selectable candela options of 15, 30, 60 &75 P tents • GEH horn is available in 12VDC or 24VDC ° 7375,617 May 20,2008 O Unit Dimensions:5" (12.7 cm)high x 4.5"(11.43 cm) wide x 2.5"(6.35 cm) Product roduct Compliance o Super-Slide®Bracket- Ease of Supervision Testing ° NFPA 72 e Checkmate®- Instant Voltage Verification 0 Americans with Disabilities Act(ADA) o Synchronize strobe and/or horn with Gentex AVSM Control Module IBC/IFC/IRC o Prewire entire system, install mounting bracket, then install signals ° Quality Management System is certified o Documented lower installation and operating costs to:ISO 9001:2008 o Input terminals accept 12 to 18 AWG o Switch selection for high or low dBA CE,,>,..:• ° Switch for chime, whoop, mechanical and 2400Hz tone MEMBER Tamperproof re-entrant style grill • Switch for continuous or temporal 3 tone (not available on whoop tone) ASSEMBLED IN o Surface mount with the GSB (Gentex Surface Mount Box) THE USA o Silence audible while visual appliance will remain flashing (for use in accepted jurisdictions) O Faceplate available in red or off-white GE', li 2VDC oEP 24VDC Low Profile Ewa cLoai bor •cm Model Number Part NumberNominal Voltage "eve -ran •c►' a n ' ec oic-.om 10ft.,per ANSVUL 464 dBA at 10ft. GEH12-R 904-1239-002 12VDC 62-82 100 GEH12-W 904-1241-002 12VDC 62-82 100 GEH24-R 904-1205-002 24VDC 62-82 100 GEH24-W 904-1207-002 24VDC 62-82 100 GES3 12V iFC or 24VDC Selectable Candela, Low Prefile v,=croatilom S ;;rti,be i Model Number Part Number Nominal Voltage Candela (ANSVUL 1971) GES3-12WR 904-1235-002 12 VDC 15,30,60, 75 GES3-12WW 904-1237-002 12 VDC 15, 30,60, 75 GES3-24WR 904-1321-002 24 VDC 15, 30, 60, 75, 110 rGES3-24WW 904-1319-002 24 VDC 15, 30, 60,75, 110 GEC3 12VDC or 24VDC Selectable Candela, Low Profile Evacuatbon Morn/Strobe Model Number Part Number Nominal Voltage Candela Reverberant dBA at in Anechoic Room (ANSVUL 1971) 10ft.,per ANSVUL 464 dBA at 10ft. GEC3-12WR 904-1231-002 12 VDC 15, 30, 60,75 62-82 100 GEC3-12WW 904-1233-002 12 VDC 15, 30, 60,75 62-82 100 GEC3-24WR 904-1317-002 24 VDC 15, 30, 60, 75, 110 62-82 100 GEC3-24WW 904-1315-002 24 VDC 15,30, 60,75, 110 62-82 100 GE3 Product Strobe Current Ratings (mA) Model Designations® 12 VDC(8-175 Volts) 24 VDC(16-33 Volts) W =Wall mount Candela 12VDC UL Max' 24VDC UL Max' R = Red Faceplate W=White Faceplate 15cd 106mA 92mA 30rnA 42mA All units are available in plain (no lettering). 30cd 131 mA 141 mA 35mA 58mA Plain units are non-returnable. 60cd 186mA 260mA 66mA 97mA 75cd 237mA 312mA 80mA 116mA ALERT bezel available for order 110cd 103mA 161mA AGENT bezel available for order 0E3-1 2 Product Horn Current Ratings 0E3-24 Product Horn Current matings Horn Decibel Levels Horn Current Ratings Horn Decibel Levels Horn Current Ratings Minimum SPL Minimum SPL Regulated 12VDC Minimum SPL Minimum SPL d 24VDC Horn Mode at 10ft.,per at 10ft.,per Max.Operating® Horn Mode at 10ft.,per at 10ft.,per RRflegullaateeratin ANSVUL 464 ANSI/1.1 464 ANSI/UL 464 ANSI/UL 484 Operating (HIGH) (LOW) High Setting(mA) High Setting(mA) (HIGH) (LOW) Temp 3 2400Hz 76 dBA 69*dBA 29mA Temp 3 2400Hz 78 dBA 71*dBA 28mA Temp 3 Mechanical 75 dBA 68*dBA 26mA Temp 3 Mechanical 76 dBA 70*dBA 25mA Temp 3 Chime 62*dBA 60*dBA 13mA Temp 3 Chime 70*dBA 66*dBA 15mA Continuous 2400Hz 79 dBA 74*dBA 29mA Continuous 2400Hz 81 dBA 74'dBA 28mA j Continuous Mechanical 78 dBA 72*dBA 26mA Continuous Mechanical 80 dBA 72*dBA 25mA Continuous Chime 63*dBA 61*dBA 13mA Continuous Chime 70*dBA 66*dBA 15mA Whoop 78 dBA 71*dBA 55mA Whoop 82 dBA 69*dBA 56mA NOTES: • Operating temperature:32°to 120°F(0°to 49°C). The GEC3 and GES3 Series is not listed for outdoor use. O For nominal and peak current across ANSI/UL regulated voltage range for filtered DC power and unfiltered(FWR[Full Wave Rectified])power,see installation manual. 12VDC models are DC only. • Gentex does not recommend using a coded or pulsing signaling circuit with any of our strobe products(see Technical Bulletin Number 014). • The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. * Operating the horn in this mode at this voltage will result in not meeting the minimum ANSI/UL 464 reverberant sound level required for public mode fire protection service. These settings are acceptable only for private mode fire alarm use. Use the high dBA setting for public mode application(not applicable when using the chime tone.The chime tone is always private mode). 1 RMS current ratings are per ANSI/UL average RMS method. ANSI/UL max current rating is the maximum RMS current within the listed voltage range(16-33VDC for 24VDC units)(8-17VDC for 12VDC units). For strobes the UL max current is usually at the minimum listed voltage(16VDC for 24VDC units)(8VDC for 12VDC units). For audibles the max current is usually at the maximum listed voltage. For unfiltered RNR ratings,see installation manual. 'fo aG S :,ii#ch Lcca#o um TONESWITCH POSITION 3 4 5 ,Io - Mechanical Temporal 3 ON ON ON -aEscoZ P Mechanical-Continuous OFF ON ON c ,v /g 2400Hz-Temporal 3 ON OFF ON 2400Hz-Continuous OFF OFF ON 1=E wEINED �- ---\ Chime-Temporal 3 ON ! ON OFF tJ Chime-Continuous OFF ON OFF �� Whoop ON OFF OFF czEuEllai N i. 011-r• Whoop OFF OFF OFF ;y+ III NOTE: am ma >z°'� P I S- �l ® Switch Positions 1 and 2 in the OFF position to A am am select isolated horn and strobe power inputs l- Di ® Switch Position 6 ON=HIGH dBA © Switch Position 6 OFF=LOW dBA (411 Gentex SuperSlide® ��i Gentex Checkmates instant Mounting Bracket Voltage Verificati Allows the installer to pre-wire It is often necessary to confirm the the system,test for system Ilik voltage dropalonga line of devices.The ri ; 9 supervision, remove the signal J " access holes are provided in the back of head until occupancy, switch _ the terminal block to allow the voltage to out Gentex signals without be measured directly without removing the AK changing mounting brackets ;; device.Typically this would be done at the and has locking edge connector \(111111tt ( end of the line to confirm design criteria. for snap-in-place installation. Most measurements will be taken using the S+and S-locations although access '� ! is provided to other locations. *Nom mi. " �' NOTE:Care should be taken to not short :C 001 n the test probes. / Candela selection slider -- switch. Depress center _ —• .; -- �— and slide switch to desire - Of'. ,� 7 7,-- :•------"::::::::2\ i brightness level. le" •,',r � s f I 11 t 1 I 1 r j :, l I ii ri !� lad � r`y L I .-Break off pfn and insert t 'fij II into hole at the bottom of0 1 N the selector to lock !1 �75 ..�. ! ' , li 1`fie. MODEL �� 4-1 1 I � I I. candela setting. Signal i(' sE� I' I �--I �,li MARKER iI i '� �I '.� + i I, ii ri EP.���� must be removed from 0 ti lwinIt iiii1it , 11 E HI ?t bracket and pin pushed - -� sir I 1 I!,__ ! f ! r� ^ , ' forward from backside out a , of hole to change (' �� = '0 l f f ~ candela. - yr.;,;-—— To remove bezel, grip both sides of bezel and pull in a downward and outward motion. , tk,,,,t, ,;,V.,,,,,- .�t{ ) �a 4: N Jty.,. W 4 i ik tt� ':.}t•f ���„„„1,,,j,,, '=f 1,',4`,,,,,.. , i .A{ j� ; 'r,r{{ 1 iA 4i.r 4 }4y.1 n A�t,} - w w., 1"' 'i }" I 4 i Y C Y...4 Y 1 ufi}'x ,fit; ^'. yl: i{-'lip r,o N. U. it ����((,,{ ,l t%�t 4 4 . °>�.F ' of ,gid �'�� i"Y lr j ji ` i+£,FLL3"::'!Z:.''''' .s:.trt j Fr��.� a i ,Lt'+ * &1. i v .:,;,..,:,,,,,:,:„:7,'''..'• v"' n '. }s t't rk..k 'x1., �r ut j "1 ji+.,::: lei I i ',: Y i )` -)1}:..('... l��( F r �.1 ,t:•4, !k+3 Fr k i ^;Of: i/ ,; ,;. 4 v v u r a r. - r �! ( t.f J,�4S t �' '��r ,�...�. W t, .,� :Y . t to J {. `l t „ r� � , ^;c veli• y�`n,! i,f r � ��rY �'-s;'r�Jlft... 'l.`at 4 �it�,`s �'�U.�{'I�'s�}�4l,� f t�5��„a� t'GL,J.t �r e,�i�.. {r"1�{ ,j�.�,+ Ba`,. tf tl ',•n vi:• y,, . "•.*ll rte i� ,a; ,A, tt+ 1,`fit 1' S�,ly •. t,Ptr �,, + SMI t i 't °i. '�,r;v, +k '`t t'S E ;hj+ . fit,}',: 41,0, ,JSs3S; 4, .;t e: ^x'44`,,(, Y}, ,i 4,,. tr... Ir a 'r k ”. .^ ' R'S {f �t�i� `"' t* i � f�te�d �6 tr r t^s xit �' t , n 'w �yp yE, 't3'4t t {. s rF' rr* 'R t 1,ii l4r k,if Alk A{t', 7 t ..f,.,., r ti ...#14,14 #1 9�'',.O fi , ,,,i, r a 17 C [ (.,: t ( d t ,R. 4 '. �' ( y .L Q Sal �j4 4 a to Y h,� '.: 4 �'t �� Y f ,:71:!. 1�..' y,,4A n,t 4�f'7i' �' t '' tti 7� is § ;.i I ;, .•.•'+F J.. r , +�,, ,!4:- ," r i` t 1 * y f ! .x u 9C fA j tt JAi r„r to .. . S ',,.� 'ti, • . w} �'i`r ;:y�; '�'J�' !��`li to i1 i. J ' � T�;i y�'�Fcti u„- �.-F '+ cti, p r r f it li L 7":i a 1 r u+- 1 �`,nt a l A,, 1 f a ` ` • 1"a!' r� 1, i' i WN." ii St ` X`ftir "W t.5 ) � i �1{. t -,`'', t4 ,.I bk4v}AdgF\ 1 1M , in, � -,df x � qq"Y. Nif 5 .jp;:, ),j,. x N}i' S.;�A' ', : 4,:: N # t 1 al 1 1 3r 3 .yf, r I 4 ,} ., '4 r� • y dL.1. ':'',,,•4:•.,'4,Atli' ., , x, .i,,sE` is .a.f, ,, • u yi ..,,,.... .:',4,;,-.',.•;;':',,s',..':,.• '•;.!'.. . , . p ;I,M" Conventional Wiring Diagrams for Emergency Notification Evacuation Series UL Listed UL Listed Control Control Panel Signal Signal Panel Signal Signal s+ S+ S- H+ H- S+ s+ a- H+ H- s+ s+ S- H+ H- S+ S+ S- H+ H- Supervised [S SSSS + ► S E S Supervised Si 6 S ® ® 0 ` lit ® ® Signal Circuit 111111 Signal Circuit II \ 11111 EOT-OR E \ O _ ,� ENDOF LINE RESISTOR \ O / END OF LINE iiirRESISTOR NOTES: a All strobes are designed to flash as specified with continuous applied voltage. Strobes should not be used on coded or pulsing signaling circuits. However, use of the Gentex AVSM control module or Gentex synchronization protocol is permitted to synchronize the strobe, horn and/or mute the horn. See Technical Bulletin 014 for additional information. e FOR SYNCHRONIZATION WIRING INFORMATION, REFERENCE AVSM CONTROL MODULE DATA SHEET(551-0031) AND/OR AVSM CONTROL MODULE MANUAL(550-0284)FOR SYNCHRONIZATION MODULE WIRING DIAGRAMS. AVSM CONTROL MODULE DATA SHEET AND MANUAL CAN BE OBTAINED AT http://www.gentex.com OR CALL GENTEX CORPORATION AT 1-800-436-8391. O When synchronizing the GE3 12VDC Series,the Gentex AVSM control module or Gentex synchronization protocol MUST be used. Architect & Engineering Specifications The audible and/or visible signal shall be Gentex GEH, GES3, GEC3 Series or approved equal and shall be listed by Underwriters Laboratories, Inc.per ANSI/UL 1971 and/or ANSI/UL 464.The notification appliance shall also be listed with Factory Mutual Listing Service(FM)and the California State Fire Marshal(CSFM). The notification appliance(combination audible/visible)shall produce a peak sound output of 100dBA or greater at 12VDC or 24VDC as measured in an anechoic chamber.The signaling appliance shall also have the capability to silence the audible signal while leaving the visible signal energized with the use of a single pair of power wires.Additionally,the user shall be able to select either continuous or temporal tone output with the temporal signal having the ability to be synchronized. Unit shall be capable of being installed so that any unauthorized attempt to change the candela setting will result in a trouble signal at the fire alarm control panel. The audible/visible and visible signaling appliance shall also maintain a minimum flash rate of 1Hz or up to 2Hz regardless of power input voltage. The strobe appliance shall have an operating current of 42mA or less at 24VDC for the 15Cd strobe circuit and 92mA or less at 12VDC for the 15Cd strobe circuit. The appliance shall be polarized to allow for electrical supervision of the system wiring.The unit shall be provided with a mounting bracket with terminals and barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate.The unit shall have an input voltage range of 16-33 volts with either direct current or full wave rectified power for 24VDC models or a voltage range of 8-17.5 volts for 12VDC models. The appliance shall be capable of testing supervision without disconnecting wires,verify voltage without removing unit and be capable of mounting to a surface back box. 24 units per carton 28 pounds per carton Important Notice: 551-0050-06 G E II T )( These materials have been prepared by Gentex Corporation("Gentex")for informational purposes only,are necessarily summary,and are not purported to serve as legal advice and should not be used as such. Gentex makes no representations and warranties,express or implied,that these materials am complete and R6� A Al T l IA R accurate,up-to-date,or in compliance with all relevant local,state and federal laws,regulations and rules. M�P U 'U 8�'i @ M The materials do not address all legal considerations as there is inevitable uncertainty regarding interpretation of laws,regulations and rules and the application of such laws,regulations and rules to Fire Protection Products Group.www.gentex.com Particular tact patterns.Each person's activities can differently aged the obligations that exist under applicable laws,regulations or rules.Therefore,these materials should be used only for informational 10985 Chicago Drive a Zeeland, Michigan 49464 purposes and should not be used as a substitute for seeking professional legal advice.Gentex will not be 616.392.7195 ® 1.800.436.8391 ® 616.392.4219 Fax responsible for any action or failure to act in reliance upon the information contained in this material. Gentex Corporation reserves the right to make changes to the product data sheet at their discretion. • t • - { 4 Y 4;,, { 6 {? '144 71NsV{"A,'1$7��r• stip S� , ,4 p :r . *2;;;s:... �d 5 s p�4,{a• ni-'� tr 1{. "fi44), a + „ s• r ' h5 I t }• . t}r + r i a t'Y Hti i ' ' rP i t7 1, .m 7 1' ad . N: 1 rj r °y} "•. t,y r;T.. j' & • • c•,r • • • •fi :—;• ++ Y• � • • - •N.�{�'.•I • 1 tu�krk 34' y . 4 r� Y";' �.:{ Yr � ty}Ps. ` .. P • `d.;: .. - .. ..,....., ._...,... Outdoor Commander Series WG E C2 4 / Evacuation Signals W E Applications The Outdoor Commander Series offers dependable visible and/or audible SERIES alarms for all outdoor needs. Included with the WGE Series is the GOE or GOELP outdoor enclosure. The enclosure is made of high quality Lexan®material, providing protection from weather related conditions and allowing the necessary full candela output. This highly constructed enclosure meets various installation requirements ""~--k a t } including deterring moisture from entering the enclosures. I The Outdoor Commander Series is equipped with the 4"mounting plate which incorporates the Super-Slide®feature that allows the installer to easily test for \v1\10 ' ' supervision. The product also features a locking mechanism which secures the kz t product to the bracket without any screws showing. = ., The WGE Series also features the Checkmate®- Instant Voltage Verification feature which allows the installer to check the voltage drop draw and match it to ten blueprint. The WGE Series strobe has a minimal operating current and has a minimum _ 11'5 taE flash rate of 1Hz regardless of input voltage. r The WGE Series appliances are ANSI/UL 464 and ANSI/UL 1638 listed for use with fire protective systems and are warranted for three years from date of : ',ax£ purchase. GOELP GOE standard Features • Nominal voltage 24VDC ® Unit is shipped with ANSI/UL1638 listed WGES24-75 candela strobe or WGEC24-75 candela horn/strobe Product Listings • GOE Unit Dimensions: 5.75"(14.605 cm) high x 4.75"(12.065 cm)wide x SIGNALING 4.18"(10.617 cm) deep sm. a:i GOELP Unit Dimensions:5.75"(14.605 cm) high x 4.75"(12.065 cm) wide x 3 t 3.25"(8.255 cm) deep • To obtain outdoor listed horn, must order GEH24 and GOE/GOELP LISTED ` separately ANSI/UL 464 and ANSI/UL 1638 Listed • Super-Slide®- Ease of Supervision Testing CSFM 7135-0569:122(WGEC) • Checkmate®- Instant Voltage Verification 7125-0569:127(WGES) ® Switch selection for high or low dBA 7300-0569:124(ENCLOSURE) ® Switch for mechanical and 2400Hz tone ® MEA#285-91 E-XVI ® Switch for continuous tone or temporal 3 (not available on whoop tone) Tamperproof re-entrant grill Product Compliance ® Prewire entire system, install mounting bracket, then install signals ® NFPA 72 • Separate horn and strobe functions e Americans with Disabilities Act(ADA) • Synchronize strobe and/or horn by using Gentex AVSM Control Module IBC/IFCIIRC ® Listed to ANSI/UL1638 when used with the GOE or GOELP enclosure ® Quality Management System is certified • GOE/GOELP made of clear Lexan®-provides maximum visibility and to:ISO 9001:2008 reliability for effective visible signaling-allowing full 75cd output • Input terminals accept 12 to 18 AWG ® Faceplate available in red or off-white MEMBER ASSEMBLED IN THE USA GEl°124 V©lt Low Profile Evacuation Giorrn Model Number Part Number Nominal Reverberant dBA at In Anechoic Room Voltage 10 ft.per ANSI/UL 464 dBA at 10ft. GEH24-R 904-1205-002 24 VDC 70-82 100 GEH24-W 904-1207-002 24 VDC 70-82 100 MOTE:Must order the 01:IA or GOELP separately when Using the 00124 in an outdoor apDplieatiorao WGES24 24 V.'it LO@WY Pr'file Evacu atl=. n Outdoor Stro�s Model Number Part Number Nominal Candela Voltage (ANSI/UL 1638) WGES24-75WR 904-1219-002 24 VDC 75 WGES24-75WW 904-1220-002 24 VDC 75 WGES24-75PWR 904-1247-002 24 VDC 75 WGES24-75PWW 904-1248-002 24 VDC 75..._ WGES24-75WRLP 904-1261-002 24 VDC 75 WGES24 and WGEC24 shipped WGES24-75WWLP 904-1263-002 24 VDC 75pp WGES24-75PWRLP 904-1262-002 24 VDC 75 with the GOE or GGEL:"' WGES24-75PWWLP 904-1264-002 24 VDC 75 Outdoor Enclosure WGEC24 m 24 Volt Low Profile Evacuation Outdoor Her /Strobe Model Number Part Number Nominal Candela Reverberant dBA ?, 10ft In Anechoic Room Voltage (ANSI/UL 1638) Per ANSWL464 dBA 0 10ft. riTCt *Mff/ fiT/: ---- •iOZ5f1 rdhT+ i" ., 100 �TirZe�xiYZ57.'�TiTPir �I+YSFif IIiTiY� . 10 pZNxi3•ZW1:y:ZTiT/: 'hZSP•ZIgaIi k s meixeRztri eirNiromptIittlitLDIKIY1 t t 904-1259-002 24 VDC 70-82 100 rrGEC24-75PTiid-WWLP__ .:-1i ,I • . +l _ 904-1260-002 24 VDC 75 ® 70-82 t t Model Designations: "W"=Wall Mount "R" = Red Faceplate "W"=Off-White Faceplate "P" =Plain(no lettering) NOTE:Plain units are non-returnable. LP"=Low Profile (GOELP Enclosure) Horn Decibel Levels Horn Current Ratings Minimum SPL Minimum SPL Regulated 24VDC Horn Mode at 10 feet per at 10 feet per Max.Operating ANSI/UL 464(HIGH) ANSI/UL 464(LOW) at High Setting WGE Series Product Temp 3 2400Hz 78 dBA 71*dBA 28mA Strobe Current Ratings Temp 3 Mechanical 76 dBA 70*dBA 25mA Candela 75cd Temp 3 Chime 70*dBA 66*dBA 15mA 24 VDC 112mA Continuous 2400Hz 81 dBA 74*dBA 28mA UL Max' 170mA Continuous Mechanical 80 dBA 72*dBA 25mA Continuous Chime 70*dBA 66*dBA 15mA Whoop 82 dBA 69*dBA 56mA NOTES: ® The WGE Series is listed for outdoor use. Indoor Operating Temperature:32°to 120°F(0°to 49°C). Outdoor Operating Temperature:-31°to 150°F(-35°to 66°C). o For nominal and peak current across ANSI/UL regulated voltage range for filtered DC power and unfiltered(FWR[Full Wave Rectified])power,see installation manual. • Gentex does not recommend using a coded or pulsing signaling circuit with any of our strobe products(see Technical Bulletin Number 014). ® The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. *Operating the horn in this mode at this voltage will result in not meeting the minimum UL reverberant sound level required for public mode fire protection service. These settings are acceptable only for private mode fire alarm use. Use the high dBA setting for public mode application(not applicable when using the chime tone.The chime tone is always private mode). RMS current ratings are per ANSI/UL average RMS method. ANSI/UL max current rating is the maximum RMS current within the listed voltage range(16-33VDC for 24VDC units)(8-17VDC for 12VDC units). For strobes the ANIS/UL max current is usually at the minimum listed voltage (16VDC for 24VDC units)(8VDC for 12VDC units). For audibles the max current is usually at the maximum listed voltage. For unfiltered FWR ratings,see installation manual. Tone Switch Locations TONE SWITCH POSITION 3 4 5 Mechanical Temporal 3 ON ON ON I Q Mechanical-Continuous OFF ON ON ! � 2400Hz-Temporal 3 ON OFF ON iil II 400Hz Continuous OFF OFF ON Chime Temporal 3 ON ON OFF w EEED Chime-Continuous OFF ON OFF 4 hoop ON OFF OFF hoop OFF OFF OFF cz NOTE: °DEO ® Switch Positions 1 and 2 in the OFF position to IMKI select isolated horn and strobe power inputs ��- • Switch Position 6 ON=HIGH dBA �� ® Switch Position 6 OFF=LOW dBA �� 01E- 6¢ k ail 6- i' `� oiE - rift ® IL Gentex Checkmate® Eras ant Geste Super.Slide® V • i ' Voltage Verification Ili >unting Bracket a'* Itis often necessary to confirm the Allows the installer to pre-wire - IN, voltage drop along a line of devices.The the system,test for system I�.. . access holes are provided in the back of supervision, remove the signal the terminal block to allow the voltage to be i head until occupancy, switch 1 I`. 111 -9 measured directly without removing the out Gentex signals without device.Typically this would be done at the changing mounting brackets I.• and has locking edge �``;-; end of the line to confirm design criteria. Most measurements will be taken using the connector for snap-in-place �_' � �, , •: S+and S-locations although access is installation. =-'' provided to other locations. NOTE:Care should be taken to not short the test probes. Mounting Outd.or Enclosure Super-Slide®Mounting Plate: Super-Slide®Mounting Plate: Mounts to GOE Outdoor Enclosure Mounts to GOELP Outdoor Enclosure :: a ) J 1 / /1 ( / i www} 1 ;w',i ekti /j�7 r'f'°• 1 +��z .,, St` 1 { 7 i 7 f * .°Ycr • i}1 t-rr • 6tx < n ts• �1* ' 4c n��` sx ' } e 40 ora f SC r u_ t �vJ� , Sjr P ! k� Y. 4 t F I �i 7:. it} , tl a s,tis. r'- 7 Xtra F �¢t: r nx `+ .' y4 + y 4 P;17)?/.'� �d `ytr/,. , r�,r �' � I' t 1��� � r�,�tt�i y � �11 �sJ 4U ',t# �' t f�r'�-�Y t� + '�,i 1 • A.. r�{, �5!r l �' r $ir 'r 1'i`''r r1G. ;a rr k t�j r Y'x Alr "5 i t r `f 3+t �a�, :.fr g '� w,is�(+ ''• t tR ,,fy, r,� ,,r � 4.-04%414044, rl`r}�+ryi. ,�rAn tternfhy*F.3rw"tta.� �P') fl t, ,1 �, r w � 4 x. ,�zl� at yr r t F�� SrnT1stl �yy� Y .„y ni„, s;:ir• ik' or Cr:' ry tib a ��; k. e V jj"°k'' t Cir kd r t r'L'1 dH F ro�,s t • "+l 'iCs .} ix, j�'k fad ;,"'+d"lrJy � .,4� As , . ,, jjtt,g l f .+a __,,hhyy,t�� l rt r ,t +l.T Srr^'1- . �� t 31 .. - t +'a. 'k ' � . ,ti$ sJffi�tihs : k. •:.•/,»J*,aroma , Conventional Wiring Diagrams for Emergency Notification Evacuation Series UL UL Listed Listed Control Signal Signal Control Signal Signal Panel S+ S+ S- H+ H- S+ S+ S- H+ H- Panel S+ S+ S- H+ H- S+ S+ S- H+ H- Supervised S S Si Supervised S 6 .S 0 (i) :. e e Signal Circuit cult /111" Signal Circuit - ..,, \ 0 / "" ENDOFURE \ + 11 RESIeTOR END LINE 1110 RESISTOR \ END OF LIRE RESISTOR NOTES: • All strobes are designed to flash as specified with continuous applied voltage. Strobes should not be used on coded or pulsing signaling circuits. However,use of the Gentex AVSM control module or Gentex synchronization protocol is permitted to synchronize the strobe, horn and/or mute the horn. See Technical Bulletin 014 for additional information. • FOR SYNCHRONIZATION WIRING INFORMATION,REFERENCE AVSM CONTROL MODULE DATA SHEET(551-0031) AND/OR AVSM CONTROL MODULE MANUAL(550-0284)FOR SYNCHRONIZATION MODULE WIRING DIAGRAMS. AVSM CONTROL MODULE DATA SHEET AND MANUAL CAN BE OBTAINED AT http://www.gentex.com OR CALL GENTEX CORPORATION AT 1-800-436-8391. ® When synchronizing the GE3 12VDC Series,the Gentex AVSM control module or Gentex synchronization protocol MUST be used. Architect & Engineering Specifications The audible and/or visible signal shall be Gentex GEH, GES3, GEC3 Series or approved equal and shall be listed by Underwriters Laboratories, Inc.per ANSI/UL 1971 and/or ANSI/UL 464.The notification appliance shall also be listed with Factory Mutual Listing Service(FM)and the California State Fire Marshal (CSFM). The notification appliance(combination audible/visible)shall produce a peak sound output of 100dBA or greater at 12VDC or 24VDC as measured in an anechoic chamber.The signaling appliance shall also have the capability to silence the audible signal while leaving the visible signal energized with the use of a single pair of power wires.Additionally,the user shall be able to select either continuous or temporal tone output with the temporal signal having the ability to be synchronized. Unit shall be capable of being installed so that any unauthorized attempt to change the candela setting will result in a trouble signal at the fire alarm control panel. The audible/visible and visible signaling appliance shall also maintain a minimum flash rate of 1Hz or up to 2Hz regardless of power input voltage. The strobe appliance shall have an operating current of 42mA or less at 24VDC for the 15Cd strobe circuit and 92mA or less at 12VDC for the 15Cd strobe circuit. The appliance shall be polarized to allow for electrical supervision of the system wiring.The unit shall be provided with a mounting bracket with terminals and barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate.The unit shall have an input voltage range of 16-33 volts with either direct current or full wave rectified power for 24VDC models or a voltage range of 8-17.5 volts for 12VDC models. The appliance shall be capable of testing supervision without disconnecting wires,verify voltage without removing unit and be capable of mounting to a surface back box. 24 units per carton 28 pounds per carton Important Notice: 551-0050-06 GENTEX These materials have been prepared by Centex Corporation("Gentex")for informational purposes only,are necessarily summary,and are not purported to serve as legal advice and should not be used as such. Gentex makes no representations and warranties,express or implied,that these materials are complete and RP R cA I NI accurate,up-to-date,or in compliance with all relevant local,state and federal laws,regulations and rules. e-� ®w The materials do not address all legal considerations as there is inevitable uncertainty regarding interpretation of laws,regulations and rules and the application of such laws,regulations and rules to Fire Protection Products Group®www.gentex.com particular ten pa ems.Each person's activit es ran differentlyafenttieaWigations hat exist under applicable laws,regulations or rules.Therefore,these materials should be used only for informational 10985 Chicago Drive o Zeeland, Michigan 49464 purposes and should not be used as a substitute for seeking professional legal advice.Gentex will not be 616.392.7195 ® 1.800.436.8391 s 616.392.4219 Fax esponsible for any action or failure to act in reliance upon the information contained in this material. Gentex Corporation reserves the right to make changes to the product data sheet at their discretion. csicHs PPOTTER SELECTABLE CANDELA The Symbol of Protection CEILING MOUNT Features • Nominal voltage 24 VDC • Tamperproof field selectable candela options 15,30,75,95, 115, & 150 • Super-Slide®Bracket-Ease of Supervision Testing • Checkmate®-Instant Voltage Verification • Synchronize strobe and/or horn with Gentex AVSM Control Module W r • Prewire entire system,install mounting bracket,then install I i4 signals Documented lower installation and operating costs kt I, • Input Terminals 12 to 18 AWG Switch Selection for High or Low dBA (1111111 • Switch Selection for 2400Hz or mechanical Tone • Switch Selection for Continuous or Temporal 3 • Tamperproof re-entrant grill • Surface mount with the CLNGBB(Ceiling Surface Mount Back Box) • Silence audible while visual appliance will remain flashing(for use in accepted jurisdictions) • Faceplate available in red or off-white Operating Temperature: UL • 32°F to 120°F(0°C to 49°C).The CS Series is not listed for outdoor use. LISTED Unit Dimensions S3247 Product includes a 5 year warranty • 6"(15.24 cm)x 2.6"(6.604 cm) Description The Potter CS/CHS Series is a ceiling mount strobe or horn/strobe The Ceiling Mount Series comes standard with the 4" mounting plate combination that offers dependable audible and visual alarms and the which incorporates the popular Super-Slide® feature that allows the lowest current consumption. installer to easily test for supervision. The product also features a locking mechanism which secures the product to the bracket without The CS/CHS offers tamperproof field selectable candela options of 15, any screws showing. 30,75,95, 115 and 150 candela. The CS/CHS also features the patented Checkmate®-Instant Voltage The CHS horn offers a continuous or synchable temporal three in Verification feature which allows the installer to check the voltage drop 2400Hz and mechanical tone.All tones are easy for the professional to draw without removing the signal. change in the field by using switches.The models are shipped from the factory in the temporal three alarm mode. The CS Series appliances are ANSI/UL 464 and ANSI/UL 1971 listed for use with fire protective systems. The CS Series has a very minimal operating current and has a minimum flash rate of 1Hz regardless of input voltage. PotterElectricSignal Company,LLC•St.Louis,MO 63042 USA.CustService:866-572-3005.Tech Support:866-956-0988•Canada 888-882-1833•www.pottersignal.com 411021,6 411WIXEMORM aSam PRINTED IN USA MFG.#8830051-REV A PAGE 1 OF 4 06/13 PjfJ? SELECTABLE CANDELA N The Symbol of Protection CEILING MOUNT Mounting Super-Slide® 3.Snap Cover Over Assembly 2.Insert Locking Screw / 10.44-ioboxii ! Aiekl,.11r:WAIIIIthbk. Nilb,, &MA ill.H.d0 1 '4111111111%":1111111.100011001111."- -MI k ' OM Iii , , _ 1 I4, , 141 7 ,IIIIIIIII ...........,4 =,,oi...._. .,„„„,,,, ,...................,,,,,,,iliwv_ _ ; MI / ;......\ l \ 1: y J •. 1.Slide Onto Bracket Checkmate®Instant Voltage Verification Switch Locations r 1 .i\a,.\ 12345 (t) L{ 1 rt--h DO NOT MINT 4 1 CI 0 cii) o o ' ® Ammilimmit Y V _ Malli F " a - '4Pll S. mei 15 �ryg O H. 1=1 inimanioner Inior N i "- ® �� � F , o 1, O Q C > M O Var ♦% \* -�/, NO , / ./ ' v (®1ENTEr N.) / 1n\ O The access holes are provided in the back of the terminal block to Switch positions I and 2 in the down position to select isolated horn allow the voltage to be measured directly without removing the and strobe power inputs.Switch 3 selects between temporal or non- device.Typically this would be done at the end of the line to confirm temporal tone.Up is temporal.Switch 4 selects between mechanical or design criteria.Most measurements will be taken using the S+and high frequency tone.Up is mechanical.Switch 5 selects between high S-locations although access is provided to other locations.NOTICE: or low dBA.Up is high dBA. CARE SHOULD BE TAKEN TO NOT SHORT THE TEST PROBES. PotterElectric S ignal Company,LLC•St.Louis,MO 63042 USA•CustService:866-572-3005•Tech Support:866-956-0988-Canada 888-882-1833•www.pottersignal.com w PRINTED IN USA MFG.#8830051-REV A PAGE 2 OF 4 06/13 P:, POTTER SELECTABLE CANDELA "® The Symbol of Protection CEILING MOUNT CS Series 24 Volt Ceiling Mount Selectable Strobe Model Part Nominal Number Number Voltage Candela CS-24R 4890020 24 VDC 15,30,75,95, 115, 150 CS-24W 4890021 24 VDC 15,30,75,95, 115, 150 CS-24PR 4890022 24 VDC 15,30,75,95, 115, 150 CS-24PW 4890023 24 VDC 15,30,75,95, 115, 150 CHS Series 24 Volt Ceiling Mount Selectable Horn/Strobe Model Part Nominal Reverberant dBA @ In Anechoic Room Number Number Voltage Candela 10 ft.per ANSI/UL 464 dBA @ 10 ft. CHS-24R 4890040 24 VDC 15,30,75,95, 115, 150 81-86 90 CHS-24W 4890041 24 VDC 15,30,75,95, 115, 150 81-86 90 CHS-24PR 4890042 24 VDC 15,30,75,95, 115, 150 81-86 90 CHS-24PW 4890043 24 VDC 15,30,75,95, 115, 150 81-86 90 Model Designations: C=Ceiling Mount S=Strobe HS=Horn/Strobe R=Red Faceplate W=White Faceplate All units are available in plain(no lettering). Plain units are non-returnable. CS24 Product Strobe Current Ratings(mA) Candela 15 cd 30 cd 75 cd 95 cd 115 cd 150 cd 24 VDC 24 VDC 72 mA 101 mA 167 mA 200 mA 214 mA 286 mA (16-33 Volts) UL Max' 120 mA 120 mA 200 mA 220 mA 290 mA 321 mA CHS24 Product Horn Decibel and Current Ratings(mA) Horn Minimum dBA @ 10 ft. Minimum dBA @ 10 ft. Regulated 24 VDC Mode per ANSI/UL 464 per ANSI/UL 464 Max.Operating (HIGH) (LOW) @ High Setting(mA) Temp 3 2400Hz 83 75 23 Temp 3 Mechanical 81 73* 22 Continuous 2400Hz 86 78 23 Continuous Mechanical 84 76 22 NOTES: • The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating.While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. • For nominal and peak current across UL regulated voltage range for filtered DC power and unfiltered(FWR[Full Wave Rectified])power, see installation manual. • Potter does not recommend using a coded or pulsing signaling circuit with any of our strobe products. • Operating the horn in this mode at this voltage will result in not meeting the minimum ANSI/UL 464 reverberant sound level required for public mode fire protection service.These settings are acceptable only for private mode fire alarm use.Use the high dBA setting for public mode application(not applicable when using the chime tone.The chime tone is always private mode). • RMS current ratings are per UL average RMS method.UL max current rating is the maximum RMS current within the listed voltage range (16-33VDC for 24VDC units).For strobes the UL max current is usually at the minimum listed voltage(16VDC for 24VDC units).For audibles the max current is usually at the maximum listed voltage.For unfiltered FWR ratings,see installation manual. Potter Electric Signal Company,LLC•St.Louis,MO 63042 USA.Cost Service-866-572-3005•Tech Support:866-956-0988•Canada 888-882-1833•www pottersignal.corn PRINTED IN USA MFG.#8830051-REV A PAGE 3 OF 4 06/13 �S1C1-� P POTTER SELECTABLE CANDELA ® The Symbol of Protection CEILING MOUNT Architect&Engineering Specifications The visible and audible/visible signal shall be Gentex model GCS or GCC or approved equal and shall be listed by Underwriters Laboratories Inc.per ANSI/UL 1971 for the GCS and ANSI/UL 464 for the GCC.The notification appliance shall also be listed with the California State Fire Marshal(CSFM). The notification appliance(combination audible/visible units and audible units only)shall produce a peak sound output of 90dBA or greater as measured at 24VDC in an anechoic chamber.The signaling appliance shall also have the capability to silence the audible signal while leaving the visible signal energized with the use of a single pair of power wires.Additionally,the user shall be able to select either continuous or temporal tone output with the temporal signal having the ability to be synchronized. The audible/visible and visible signaling appliance shall also maintain a minimum flash rate of 1Hz or up to 2Hz regardless of power input voltage.The appliance shall have an operating current of 72mA or less at 24VDC for the 15 candela strobe circuit. The appliance shall be polarized to allow for electrical supervision of the system wiring.The unit shall be provided with a mounting bracket with terminals with barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox with the use of an adapter plate.The unit shall have an input voltage range of 16-33 volts with either direct current or full wave rectified power. The appliance shall be capable of test supervision without disconnecting wires,verify voltage without removing unit and be capable of mounting to a surface back box. Conventional CS/CHS Series Wiring Diagrams UL Listed UL Listed Control Signal Signal Control Panel Panel Signal Signal S+ S+ S- H+ H- S+ S+ S- H+ H- S+ S+ S- H+ H- S+ S+ S- H+ H- Supervised 9 SS SI ► O i� it Supervised 19 IS S B 0 S 611 S S B Signal Circuit 111111Imp Signal Circuit I \ 0+ "'t \ O 3 END OF LINE END OF LINE O RESISTOR ORESISTOR „ \ O / END OF RE RESISTOR NOTES: • All strobes are designed to flash as specified with continuous applied voltage.Strobes should not be used on coded or pulsing signaling circuits.However,use of the Gentex AVSM control module or Gentex synchronization protocol is permitted to synchronize the strobe,horn and/or mute the horn. • FOR SYNCHRONIZATION WIRING INFORMATION,REFERENCE AVSM CONTROL MODULE DATA SHEET(8830050) AND/OR AVSM CONTROL MODULE MANUAL FOR SYNCHRONIZATION MODULE WIRING DIAGRAMS.AVSM CONTROL MODULE DATA SHEET AND MANUAL CAN BE OBTAINED AT http://www.pottersignal.com OR CALL POTTER ELECTRIC AT 1-800-325-3936. Potter ElectricSignalCompany,LLC•St.Louis,MO 63042 USA•CustService:866-572-3005•Tech Support:866-956-0988•Canada 888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#8830051-REV A PAGE 4 OF 4 06/13