Loading...
Report 93S2O19-boo-to t1O9O Sit/ 6sth PKWY PATRIOT 4708 NE MINNEHAHA ST VANCOUVER,WA 98661 FIRE PROTECTION TEL(360)699-4403 FAX(360)699-4485 �s tea.y....- .a.,., _.,..I I�-•r�,� Red Rock Creek Commons Data Sheets JOB # 31-1451 TACOMA,WA OFFICE www.patriotfire.com SPOKANE,WA OFFICE TEL(253)926-2290 PATRIFP099CF TEL(509)926-3428 FAX(253)922-6150 FAX(509)926-3708 4708 E ST PRE VWA HA VANCOUVER,WA 98661 FIRE PROTECTION TEL(360)699-4403 FAX(360)699-4485 EQUIPMENT SUBMITTAL Red Rock Creek Commons Tigard, OR Patriot Fire Protection Inc. Job#31-1451 ITEM MANF. MODEL SIZE COMMENTS *** SPRINKLERS *** CONCEALED- RA1414 Reliable F1FR56 1/2" 155 deg. QR: SSU Reliable F1FR56 1/2" 155 deg. CONCEALED- R3516 Reliable F1RES49 1/2" 155 deg. QR: Dry Sidewall Reliable F3QR56 1" 155 deg. KFR-CCS SSU Reliable KFR-CCS 1/2" 212 deg. *** VALVES *** Butterfly Valve Reliable REL-BFG-300 Varies w/ Tamper Switch Check valve Reliable G 1-1/2" -4" Riser Manifold Reliable CR 1-1/2" & 2" Post Indicator Butterfly Nibco WP 4" w/ Tamper Switch Fire Hose Valve 'otter Roemer 4065 2 1/2" GxG, w/ cap & chain *** PIPE *** Pipe: Steel Seah Vina Sch. 10/40 All or equal, FM Apvd Pipe: CPVC Blazemaster All *** FITTINGS *** Grooved Fittings Anvil Varies 1 1/4" -8" or equal CPVC Fittings Blazemaster All *** ELECTRICAL DEVICES *** Water Flow Indicator Potter Elec. VSR All Electric Bell Sys Sensor SSM/SSV 10" or equal, 120 V TACOMA,WA OFFICE www.patriotfire.com SPOKANE,WA OFFICE TEL(253)926-2290 PATRIFP099CF TEL(509)926-3428 FAX(253)922-6150 FAX(509)926-3708 IATRIOT 4708 NE MINNEHAHA ST VANCOUVER,WA 98661 FIRE PROTECTION TEL(360)699-4403 FAX(360)699-4485 EQUIPMENT SUBMITTAL Red Rock Creek Commons Tigard, OR Patriot Fire Protection Inc. Job # 31-1451 ITEM MANF. MODEL SIZE COMMENTS *** HANGERS *** Ring Hanger Tolco 200 All or equal Vertical ATR Attachment Hilti HCI-WF 3/8" & 1/2" or equal Vertical ATR Attachment Elco EZD650-I 3/8" Vertical ATR Attachment Powers Mini-Undercut 3/8" As needed CPVC Hangers Afcon All All or equal Seismic Bracing Tolco Varies 1" TACOMA,WA OFFICE www.patriotfire.com SPOKANE,WA OFFICE TEL(253)926-2290 PATRIFP099CF TEL(509)926-3428 FAX(253)922-6150 FAX(509)926-3708 Bulletin 014 Rev.1) oo p Model Fl FR Series ReliableQuick Response 0 Glass Bulb SprinklersJOCD Model Fl FR56 Sprinkler Types ., ,. r Standard Spray Upright ' - Standard Spray Pendent Conventional Upright/Pendent �+ Vertical Sidewall `t- - Horizontal Sidewall -`� ' Model Fl FR56 Recessed Sprinkler Types Upright Pendent Conventional Standard Spray Pendent .. Horizontal Sidewall Model Fl FR56 Concealed Sprinkler Types ' ' Standard Spray Pendent ,N,,, ` . Model F1 FR42, F1 FRXLH & F1 FR28 Sprinkler ,5 Types Standard Spray Upright Vertical Sidewall Horizontal Sidewall Recessed Pendent/F1/F2 Standard Spray Pendent Model Fl FR40 Sprinkler Types Standard Spray Pendent ,,k Model Fl FR42, Fl FR40, Fl FRXLH & Fl FR28 (' ,e A I, I'. Recessed Sprinkler Types f A, -, y, Standard Spray Pendent "'�`: + . :r: Model F1 FR56LL&F1 FR42LL Low Lead Sprinkler Recessed Concealed Recessed Types Horizontal Sidewall Pendent Pendent/FP Standard Spray Pendent with less than 0.25% Lead Content Listing &Approvals + (4w44 The following organizations provide Listings or Approvals 11 for various Model Fl FR series sprinklers. See the Design and Installation table in this Bulletin for information on XLH Upright XLH Pendent XLH Recessed specific listings and approvals applicable to each sprin- Pendent F1/F2 kler. Product Description 1. Underwriters Laboratories Inc. and Certified for Reliable Model F1FR series sprinklers Canada (cULus) in accordance with ANSI/UL199. 2. FM Approvals (FM) are quick-response automatic sprin- ' '1' f 3. Loss Prevention Certification Board (LPCB) klers with a glass bulb thermal element. 4. VdS Schadenverhutung GmbH (VdS) Model F1FR series sprinklers are Stan 5. Underwriters Laboratories Inc. and Underwriters dard Spray sprinklers, with the excep Laboratories of Canada Certified for Health Effects tion of the Model F1FR56 Conventional XLH Recessed to NSF/ANSI Standard 61 Annex G (ULH) sprinkler which is an Old-style/Conven- Pendent FP tional 6. EC Certificate: 0786-CPD-40239 (RA1414), 0786- sprinkler. CPD-40251 (RA1425), 0786-CPD-40252 (RA1475) The Moodkler. del F1FR Series automatic sprinklers utilize a 3.0 (EC) mm frangible glass bulb.These sprinklers have demonstrat- ed response times in laboratory tests which are five to ten UL Listing Category times faster than standard response sprinklers. This quick Sprinklers, Automatic&Open (VNIV) response enables the Model F1FR Series sprinklers to apply- Quick pplyQuick Response Sprinkler water to a fire faster than standard-response sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amounf of special fluid hermetically sealed inside a precisely man- ufactured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 At normal temperatures, the glass bulb contains the fluid Model F1 FR Series sprinklers must be installed with the in both the liquid and vapor phases. The vapor phase can Reliable sprinkler installation wrench identified in the Design be seen as a small bubble. As heat is applied, the liquid and Installation Information table in this Bulletin. Any other expands,forcing the bubble smaller and smaller as the liq- wrench may damage the sprinkler. A leak tight sprinkler joint uid pressure increases. Continued heating forces the liquid can be obtained with a torque of 8 to 18 lb-ft(11 to 24 N-m). to push out against the bulb, causing the glass to shatter, Do not tighten sprinklers over the maximum recommended opening the waterway and allowing the deflector to distrib- installation torque. Exceeding the maximum recommended ute the discharging water. installation torque may cause leakage or impairment of the Model Fl FR Series sprinklers provide a wide range of op- sprinkler. tions where quick-response,glass bulb sprinklers are used: Recessed Sprinklers • Pendent, recessed pendent, upright, horizontal Model Fl FR Series Recessed sprinklers are to be installed sidewall, and vertical sidewall deflectors as shown in Fig. 1,Fig.2,or Fig.3,as applicable to the spe- • K-factors of 2.8 (40 metric), 4.0 (57 metric), 4.2 (60 cific model being installed.The Recessed Escutcheon Data metric), and 5.6 (80 metric) table in the Bulletin identifies the only recessed escutcheons • Flush, recessed, and concealed installations that are permitted to be used with each Model Fl FR Series See the Design and Installation Information table in this Recessed sprinkler.The use of any other recessed escutch- Bulletin for information on the approvals and availability of eon will void all approvals and negate all warranties. specific Model Fl FR series sprinkler configurations. Concealed Sprinklers Model F1 FR Recessed Pendent and Recessed Horizon- Model F1 FR Series Concealed Pendent sprinklers are to tal Sidewall sprinklers are required to be used with Reliable be installed as shown in Fig.4 or Fig.5,as applicable to the Model F1, F2, or FP recessed escutcheons. See the Re- selected cover plate. Model F1FR56 Concealed Pendent cessed Escutcheon Data table in this Bulletin for listing and and Model F1FR56LL Concealed Pendent sprinklers have approval information with each specific Model F1 FR series a factory-installed Model CCP cup. A protective cap is in- sprinkler. Model Fl and F2 recessed escutcheons,shown in stalled at the factory that should remain on the sprinkler until Fig. 1 and 3, are a friction fit assembly allowing for 3/4-inch the sprinkler is installed and should then be reinstalled on (19mm)and 1/2-inch (12.7mm)of adjustment, respectively, the sprinkler until the cover plate is installed.The concealed Model FP recessed escutcheons,shown in Fig. 2,provide a sprinkler assemblies are completed by the installation of a 1/2-inch(12.7mm)threaded adjustment. Model CCP push-on/thread-off cover plate assembly. The Model F1FR56 Concealed Pendent and Model F1FR56LL cover plate and sprinkler cup assemblies are joined using Concealed Pendent sprinklers are required to be used with a cover plate skirt with flexible tabs for threaded engage- Model CCP cover plates.A standard profile Model CCP coy- ment. A choice of two Model CCP cover plate assemblies er plate is available that provides up to 1/2-inch(12.7mm)of provides either 1/2-inch (13mm)or 5/8-inch (8mm)of cover cover plate adjustment. In addition,a low profile Model CCP adjustment. Do not install Model Fl FR Series Concealed cover plate is also available that provides up to 5/16-inch Pendent sprinklers in ceilings which have positive pressure (8.0mm) of cover plate adjustment. See the Design and In- in the space above. stallation Information and Listed and Approved Temperature Model F1 FR Series Concealed Pendent sprinklers require a Ratings tables in this Bulletin for further information on ap- 2-5/8-inch (67mm) diameter hole to be cut in the ceiling. The proved cover plate options. Model RC1 wrench is used to engage the sprinkler wrenching Application surfaces and to install the sprinkler in the fitting. Remove the Model Fl FR Series sprinklers are intended for use in protective cap to install the sprinkler,then reinstall the protective accordance with NFPA 13, FM Property Loss Prevention cap until the cover plate is installed. When inserting or remov- Data Sheets, and the requirements of the Authority Hay- ing the wrench from the sprinkler/cup assembly,care should be ing Jurisdiction. Care must be exercised that the k-factor, taken to prevent damage to the sprinkler. Do not wrench any temperature rating, deflector style,and sprinkler type are other part of the sprinkler/cup assembly. Installation is com- in accordance with the requirements of the applicable pleted by removing the protective cap from the sprinkler and design and installation standards. In addition, Model pushing the cover plate onto the cup.Final adjustment is made Fl FR Series sprinklers must be used in accordance with by hand turning the cover plate until the skirt flange makes full their listings and approvals, as well as the information contact with the ceiling.Cover plate removal requires turning the provided in this Bulletin. cover plate in the counter clockwise direction.After installation, Installation inspect all sprinklers to ensure that there is a gap between the Glass bulb sprinklers have orange bulb protectors or pro- cover plate and ceiling and that the four cup slots are open and tective caps to minimize bulb damage during shipping,han- free from any air flow impediment to the space above. dling and installation. Reliable sprinkler installation wrench- Concealed cover plate/cup assemblies are listed only for es are designed to install sprinklers with bulb protectors in use with specific sprinklers.The use of any concealed cover place.Remove the bulb protector at the time when the sprin- plate/cup assembly other than the Reliable Model CCP with kler system is placed in service for fire protection. Removal Model F1FR56 Concealed Pendent and Model F1FR56LL of the bulb protector before this time may leave the bulb vul- Concealed Pendent sprinklers or the use of the Model CCP nerable to damage. Remove bulb protectors by undoing the Concealed cover plate assembly on any sprinkler with clasp by hand. Do not use tools to remove bulb protectors. which it is not specifically listed my prevent good fire pro- tection and will void all guarantees, warranties, listings and approvals. 2. Technical Data: Sensitivity: Quick-response Thread Size: 1/2-inch NPT standard; ISO 7-R1/2 optional Maximum Working Pressure: 175 psi (12 bar)- 100% Factory tested hydrostatically to 500 psi (34.5 bar) SIN RA1425, RA1414& RA1435 cULus listed for 250 psi (17 bar) Design and Installation Information Nominal Nominal Nominal Orifice Sprinkler Listings K-factor Deflector/ Installation Approval _ Model Diameter Orientation Height Wrench SIN and Notes Approvals US Metric inches mm inches mm Pendent 2.25 57 Dor W2 RA1411 cULus 2 F1FR28 2.8 40 3/8 10 Recessed Pendent 2.25 57 GFR2 RA1411 cULus 2 Upright 2.25 57 Dor W2 RA1421 cULus 1,2 F1 FR40 4.0 57 3/8 10 Pendent 2.25 57 Dor W2 RA1418 VdS Recessed Pendent 2.25 57 GFR2 RA1418 VdS Pendent 2.25 57 D or W2 RA1413 cULus 2 F1FR42 4.2 60 7/16 10 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 Upright 2.25 57 D or W2 RA1423 cULus 1,2 F1FR42LL 4.2 60 7/16 10 Pendent 2.25 57 D or W2 RA1410 cULus, ULH Recessed Pendent 2.25 57 GFR2 RA1410 cULus, ULH F1FRXLH Pendent 2.25 57 Dor W2 RA1413 cULus 2 (F1FR42 4.2 60 7/16 10 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 with Pintle) Upright 2.25 57 Dor W2 RA1423 cULus 1,2 Pendent 2.25 57 Dor W2 RA1414 cULus,FM, 1,2,3,4 LPCB,VdS, EC Recessed Pendent 2.25 57 GFR2 RA1414 cULus,FM, 1,2,3,4 LPCB,VdS,EC F1FR56 5.6 80 1/2 15 Concealed Pendent 2.25 57 RC1 RA1414 cULus,VdS,EC 5,6 Upright 2.25 57 D or W2 RA1425 cULus,FM, 1,2,3,4 LPCB,VdS, EC "Conventional 2.25 57 D or W2 RA1475 LPCB,VdS,EC 4 (Pendent or Upright)" Pendent 2.25 57 Dor W2 RA1415 cULus, ULH 1 F1FR56LL 5.6 80 1/2 15 Recessed Pendent 2.25 57 GFR2 RA1415 cULus,ULH Concealed Pendent 2.25 57 RC1 RA1415 cULus, ULH 6 Horizontal Sidewall 2.63 67 Dor W2 RA1435 cULus,FM 1,2,3,7 F1FR56 5.6 80 1/2 15 Recessed Horizontal 2.63 67 GFR2 RA1435 cULus, FM 8 Sidewall F1FR56 5.6 80 1/2 15 Vertical Sidewall 2.25 57 Dor W2 RA1485 cULus, FM, 1,2,3,9 (Pendent or Upright) LPCB (')cULus Listed Corrosion Resistant sprinkler when ordered with available Polyester coating. (2)cULus Listed Corrosion Resistant sprinkler when ordered with available Electroless Nickel PTFE plating. (3)Available with FM approved Polyester coating in black or white. (4)Available with LPCB and VdS approved Polyester coating. (5)VdS and EC approvals of the F1FR56 Concealed Pendent sprinkler are for 155°F(68°C)temperature rated sprinklers only.VdS approved sprin- klers must use Norbulb brand glass bulbs with the 1/2-inch(12.7mm)adjustment Model CCP cover plate only. (6)Model F1FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates, available as either standard depth with 1/2-inch(12.7mm)of adjustment or low profile with 5/16-inch(8.0 mm)of adjustment. (7)cULus Listing of the F1FR56 Horizontal Sidewall sprinkler is for Light and Ordinary Hazard occupancies only. FM Approval of the F1FR56 Hori- zontal Sidewall sprinkler is for Light Hazard occupancies only. (6)cULus Listing and FM Approval of the Fl FR56 Recessed Horizontal Sidewall sprinkler is for Light Hazard occupancies only. (9)The F1FR56 Vertical Sidewall sprinkler is listed and approved for use only in Light Hazard occupancies.Minimum to maximum deflector to ceil- ing distance shall be 4 inches to 12 inches(102mm to 305mm).LPCB approval of the F1FR56 Vertical Sidewall sprinkler is for installation in the Pendent position only. 3. Listed and Approved Temperature Ratings Ordinary Temp. Intermediate Temp. High Temp. Classification Classification Classification Deflector/ 100°F(38°C)Max.Ambient 150°F(65°C)Max.Ambient 225°F(107°C)Max. Model Orientation Temp. Temp. Ambient Temp. 135°F(57°C) 155°F(68°C) 175°F(79°C) 200°F(93°C) 286°F(141°C)Temp. Temp. Rating Temp.Rating Temp.Rating Temp.Rating Rating Orange Bulb Red Bulb Yellow Bulb Green Bulb Blue Bulb Pendent cULus F1FR28 Recessed Pendent cULus -- Upright cULus F1FR40 Pendent VdS Recessed Pendent VdS -- - Pendent cULus F1FR42 Recessed Pendent cULus -- Upright cULus F1FR42LL Pendent -- cULus,ULH -- Recessed Pendent -- cULus,ULH -- Pendent cULus F1 FRXLH Recessed Pendent cULus -- Upright cULus Pendent cULus,FM, LPCB,VdS,EC Recessed Pendent cULus,FM, LPCB,VdS, EC -- F1FR56 Concealed Pendent' cULus cULus,VdS,EC cULus -- Upright cULus, FM, LPCB,VdS, EC "Conventional LPCB,VdS, EC (Pendent or Upright)" Pendent -- cULus,ULH -- F1FR56LL Recessed Pendent -- cULus,ULH -- Concealed Pendent* -- cULus,ULH -- Horizontal Sidewall cULus,FM F1FR56 Recessed Horizontal cULus, FM Sidewall - F1FR56 Vertical Sidewall(Pen cULus,FM,LPCB dent or Upright) * Model Fl FR56 Concealed Pendent and Fl FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates. For Ordinary Temperature Classification sprinklers use a 135°F (57°C) temperature rated cover plate. For Intermediate Temperature Classification sprinklers use a 165°F(74°C) temperature rated cover plate. Recessed Escutcheon Data Listed and Approved Recessed Escutcheons Deflector/ Model F1 Model F2 Model FP Model Orientation (Fig. 1 &3) (Fig. 1 &3) (Fig.2) SIN 3/4-inch(19mm) 1/2-inch(12.7mm) 1/2-inch(12.7mm) adjustment adjustment adjustment F1FR28 Recessed Pendent cULus cULus cULus RA1411 F1FR40 Recessed Pendent VdS VdS VdS RA1418 F1FR42 Recessed Pendent cULus cULus cULus RA1413 F1FR42LL Recessed Pendent cULus,ULH cULus, ULH cULus,ULH RA1410 F1FR42XLH Recessed Pendent cULus cULus cULus RA1413 F1FR56 Recessed Pendent cULus, LPCB,VdS, cULus,FM, LPCB, cULus,VdS,EC RA1414 EC VdS, EC F1FR56LL Recessed Pendent cULus,ULH cULus, ULH cULus, ULH RA1415 F1FR56 Recessed Horizontal Sidewall cULus cULus,FM cULus RA1435 4. 2 1/4"HOLE DA. J [57.2mm] 1 15/16'DIA J [49.2mm] L—===—=---=—======.--=-:_- 1"X 1/2" REDUCER TURN COLLAR IT -V UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS \ / FACE OF FITTING \ TO FACE OF CEILING DIMENSION �— / —� ll �I F1 ESCUTCHEON SII (I -1 II AT MAXIMUM RECESS = 1'[25.4mm] �� AT MINIMUM RECESS = 3/8'[9.5mmJ F1 ESCUTCHEON L .�` J F2 ESCUTCHEON 3/4'[19mmJ �A ,1* �'y AT MAXIMUM RECESS = 3/4(19mm] '. ADJUSTMENT AT MINIMUM RECESS = 3/8'[9.5mm] F2 ESCUTCHEON �I cosvu Il /� 1/2'[12.7mm] O �1 �_ ��11 //(//�A ADJUSTMENT I III IliJ J Fl ESCUTCHEON III il1 1/8' AT MAXIMUM RECESS = 7/88"[41. m] [3.2mmJAT MINIMUM RECESS = 1-5/8'[41.3mmJ l�j F2 ESCUTCHEON `S.\41- �, ' AT MAXIMUM RECESS = 1-1/8'[28.6mm] 4AT MINIMUM RECESS = 1-5/8[41.3mm] "•2 27/32"DIA..• [72.2mm] 'en.] Fig. 1 Model F1 FR56,F1 FR56LL,F1 FR42,F1 FR40,F1 FR42LL,F1 FRXLH&F1 FR28 Recessed Pendent sprinkler with Model F1 or F2 escutcheon L_ -4 II I 1" X 1/2" REDUCER 2 5/8" DIA. [66.7mm] HOLE IN CEILING 2 5/16" DIA. [58.7mm] CUP .4....... .., CEILING -- ������. FACE OF FITTING TO FACE OF CEILING 1 03SV8 1I'll DIMENSION { _ __ I'll � .o1111 �II�II % AT MAXIMUM RECESS = 1-1/2[38mmJ 1 liti AT MINJMVM RECESS = 1'[25.4mm] IV . `,�4, �' AT MAXIMUM RECESS = 9/16[14.3mm] %2(12.7mm] �„�� AT MINIMUM RECESS = 1[25.4mm] ADJUSTMENT ,,,. _ ..., 3.1/4' DIA. t NO- [82.8Mm] Fig.2 Model Fl FR56,F1 FR56LL,F1 FR42,F1 FR40,F1 FR42LL,F1 FRXLH&F1 FR28 Recessed Pendent sprinkler with Model FP escutcheon 5. FACE OF FITTING TO FACE OF CEILING DIMENSION F1 ESCUTCHEON jl / AT MAXIMUM RECESS = 1[25.4mm] AT MINIMUM RECESS = 3/8'[9.5mm] z Fl ESCUTCHEON F2 ESCUTCHEON AT MAXIMUM RECESS = 1-3/8[34.9mm] AT MAXIMUM RECESS = 3/4"[19mm] / AT MINIMUM RECESS = 2-1/16[52.4mm] AT MINIMUM RECESS = 3/8[9.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 1-5/8141.3mm] 2 1/4" HOLE DIA. 8"" AT MINIMUM RECESS = 2-1/16[52.4mm] - [57.2mm] --n --",-1/ -- [3.2mm] 1" X 1/2" REDUCER n) l. r-,_ 4r--I I l I�hlll� -"r7 (i) liinil N. 4"-12" 1 15/16"" DIA.`/nw l _ _ !! HI ` 101.6mm-304.8mm [49.2mm] Hill—7-- illi 2 27/32" DIA. [ ] i IN;; [[ I / CEILING TO �_I�ul ,_ ��—' — [72.2mm] DEFLECTOR TURN COLLAR UNTILTIGHT AGAINST WRENCH BOSS.SPRINKLER F1 ESCUTCHEON 3/4[19mm] ADJUSTMENT —.--, F2 ESCUTCHEON 1/2"[12.7mm] ADJUSTMENT OI RECESSED HSW W/F1 OR F2 ESCUTCHEON (1) FM APPROVED FOR 4" — 6" [101.6MM — 152.4MM] CEILING TO DEFLECTOR WITH F2 ONLY. Fig.3 Model Fl FR56 Recessed Horizontal Sidewall sprinkler with Model Fl or F2 escutcheon 1" x 1/2" REDUCING TEE OR ELBOW -------- - —E - - - 4 — —+- - - - �} - - - — r- - 2 5/8" DIA. 2 5/16" CIA — ' `; HOLE IN CEILING L J CUP —,�_ =`.'— i Oa`! /2" MAX. �I_ !I�' ` 1 1 ;;,;;;;;1 III If �� FACE OF FITTING " kIII1 TO FACE OF CEILING 1i i i i i i iCEILING /////// t 1/2" MAX. - COVER ADJUSTMENT 15/16" COVER PLATE ASSEMBLY /3 5/76" DIA. SPRINKLER / CONCEALED, 1/2" ADJUSTMENT O 7FCO A Fig.4 Model F1 FR56/F1 FR56LL Concealed Pendent sprinkler with standard depth 1/2-inch(12.7mm)adjustment-Model CCP cover plate 6. 1 2" 1" x REDUCING - - - - TEE ORR ELBOW ._ -------- - - - 1,T, - - - }} -- - -+- -- - ii- -- 1 __ 2 5/8" DIA. 2 5/16" DIA — L' HOLE IN CEILING L_ i CUP =i � ' I ` IIIII�_o -IIT 1 1/2" MAX. FACE OF FITTING /;'//74_--/;;;//T:[ �l �l�ryJl 11 III _ TO FACE OF CEILING .:.l 11 i ::7-/////77,- DIMENSION CEILING ,\ I i---- i =�� ,p,,/_� _. 5/16" MAX. __ 3/4" COVER ADJUSTMENT COVER PLATE / I I 1 ASSEMBLY - 3 5/16" DIA. SPRINKLER CONCEALED, 5/1 6" ADJUSTMENT 017FGO2A Fig.5-Model F1 FR56/F1 FR56LL Concealed Pendent sprinkler with low profile 5/16-inch(8.0mm)adjustment-Model CCP cover plate Maintenance Material Data The Model Fl FR Series sprinklers should be inspected and Frame: DZR Brass,QM Brass,or Low Lead Brass the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water,ammonia or Deflector: CDA Alloy 220,260,or 510 _ any other cleaning fluids.Remove dust by using a soft brush Load Screw\Pintle: CDA Alloy 360 or 544 or gentle vacuuming.Replace any sprinkler which has been Cup: CDA Alloy 651 or 693 painted(other than factory applied)or damaged in any way. Washer: Nickel Alloy 440 or 360,coated with PTFE A stock of spare sprinklers should be maintained to allow Adhesive Tape quick replacement of damaged or operated sprinklers. Bulb: Glass Finishes (1) Standard Finishes Sprinkler Escutcheon Cover platem Ordering Information Bronze Brass Chrome Specify: Chrome Plated Chrome White 1. Sprinkler Model: [F1FR28][F1FR40][F1FR42] Polyester Plated [F1 FR42LL][F1 FRXLH][F1 FR56][F1 FR56LL] Coated(4)(5)(6) White Painted Special Application Finishes 2. Sprinkler Deflector/Orientation: [Pendent][Recessed Sprinkler Escutcheon Cover platen Pendent][Upright][Conventional][Horizontal Sidewall] Electroless Nickel Electroless Nickel Bright Brass [Recessed Horizontal Sidewall][Vertical Sidewall] PTFE(7) PTFE Bright Brasso) Bright Brass Black Plating 3. Sprinkler threads: [1/2-inch NPT][ISO 7-R1/2] Black Plated Black Plated Black Paint 4. Sprinkler Temperature Rating: [135°F (57°C)][155°F Black Painto)(6) Black Paint Off White (68°C)][175°F(79°C)][200°F(93°C)][286°F(141°C)] Off Whiteo)(6) Off White Satin Chrome Chrome Dull Chrome Dull 5. Sprinkler Finish (1)Other finishes and colors are available on special order. Consult the 6. Escutcheon Model: [F1][F2][FP] factory for details.Custom color painted sprinklers may not retain their 7. Escutcheon Finish (where applicable) UL Corrosion resistance listing.Coverplate custom paint is semi-gloss, 8. Cover plate Model: [standard profile CCP 1/2-inch unless specified otherwise. (12.7mm) adjustment][low profile CCP 5/16-inch (2) cULus Listed only. (8.0mm) adjustment] (3) 200°F(93°C)maximum. (4) cULus listed "corrosion resistance" applies to SIN Numbers RA1435 9. Cover plate Temperature Rating: [135°F(57°C)for use (HSW), RA1485(VSW), RA1425 (Upright), RA1414 (Pendent) and with Ordinary Temperature sprinklers][165°F (74°C)- RA1415 (Pendent) in standard black or white. Corrosion resistance in for use with Intermediate Temperature sprinklers] other polyester colors is available upon request. 10. Cover plate Finish (5) FM Approvals finish as"Polyester coated"applies to SIN Number RA1414,RA1435 and RA1425 in standard black or white. - (6)LPCB and VdS Approved finish applies only to RA1425,RA1414,RA1418 Note: When Model F1FR Series Recessed sprinklers are ordered, the (VdS)and RA1475. sprinklers and escutcheons are packaged separately. (7)cULus listed Corrosion Resistant 7. Reliable. . . For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Deluge valves _ • Flush automatic sprinklers • Detector check valves • Recessed automatic sprinklers • Check valves • Concealed automatic sprinklers • Electrical system • Adjustable automatic sprinklers • Sprinkler emergency cabinets • Dry automatic sprinklers • Sprinkler wrenches • Intermediate level sprinklers • Sprinkler escutcheons and guards • Open sprinklers • Inspectors test connections • Spray nozzles • Sight drains • Alarm valves • Ball drips and drum drips • Retarding chambers • Control valve seals • Dry pipe valves • Air maintenance devices • Accelerators for dry pipe valves • Air compressors • Mechanical sprinkler alarms • Pressure gauges • Electrical sprinkler alarm switches • Identification signs • Water flow detectors • Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years. Manufactured by Reliable Automatic Sprinkler Co.,Inc. *• Recycled (800)483481--61508581 Sales Offices var Paper Relabit' (800) Sales Fax Revision lines indicate updated or new data. (914)8292042 Corporate Offices www.reliablesprinkler.com Internet Address EG.Printed in U.S.A.03/17 P/N 9999970300 Bulletin 135 October 2018 Reliable Model F1 Res Series Glass Bulb Residential Sprinklers cULus Listed For NFPA 13,NFPA 13R,and NFPA 13D Applications Features • cULus Listed Residential Sprinklers • Available in pendent and horizontal sidewall orientations f i • Decorative finishes available, including recessed escutch- eons and conical concealed cover plates I Product Description - Model Fl Res Series sprinklers are residential sprinklers with a 3 mm glass bulb operating element. A variety of K-Factors as well as recessed and conical concealed options are available as detailed in this Bulletin. The Fl Res Series sprinklers are specially engineered for fast thermal response to meet the requirements of UL 1626. They 4 ,t,; are intended for installation in accordance with NFPA 13, 13R, �• and 13D. '�' a 1; l .4Y11t Application - The Model F1 Res Series sprinklers cULus Listed Residential sprinklers are intended for use in accordance with NFPA 13, - NFPA 13R, or NFPA 13D. The Model F1 Res residential sprin- Design Criteria tables in this Bulletin.For NFPA 13 applications, klers are cULus Listed for use in residential occupancies and the design density shall be a minimum of 0.1 gpm/sf(4.1 mm/ residential portions of any occupancy, where permitted by min), but in no case shall the flow and pressure be less than NFPA 13, NFPA 13R, or NFPA 13D. For NFPA 13R and NFPA the minimum flow and pressure specified in the Listed Design 13D applications, the design flow and pressure shall not be Criteria tables in this bulletin.Model F1 Res Series sprinklers are less than the minimum flow and pressure specified in the Listed listed for use in wet systems only. Residential Sprinkler Summary Table A Sprinkler Sprinkler K-Factor Thread Size Max.Coverage Area Model Identification Orientation gpm/psis NPT or IS07-1 Installation Options ft x ft m x m Number(SIN) (Ipm/bar ( ) F1Res30 R3511 Pendent 3.0(43) 1/2 Pendent or Recessed 16 x16(4.9 x 4.9) F1 Res49 R3516 Pendent 4.9(71) 1/2 Pendent or Recessed 20 x 20(6.1 x 6.1) F1 Res58 R3513 Pendent 5.8(84) 1/2 Pendent or Recessed 20 x 20(6.1 x 6.1) F1 Res76 R7618 Pendent 7.6(109) 3/4 Pendent or Recessed 20 x 20(6.1 x 6.1) F1 Res30 CCP R3511 Pendent 3.0(43) 1/2 Conical Concealed or 14 x 14(4.3 x 4.3) Recessed F1 Res49 CCP R3516 Pendent 4.9(71) 1/2 Conical Concealed or 20 x 20(6.1 x 6.1) Recessed F1 Res58 CCP R3513 Pendent 5.8(84) 1/2 Conical Concealed or 20 x 20(6.1x 6.1) Recessed F1Res76 CCP R7618 Pendent 7.6(109) 3/4 Conical Concealed or 20 x 20(6.1 x 6.1) Recessed F1 Res44 HSW R3531 Horizontal Sidewall 4.4(63) 1/2 Recessed 16 x 20(4.9 x 6.1) F1 Res44 SWC R3531 Horizontal Sidewall 4.4(63) 1/2 Conical Concealed 16 x 20(4.9 x 6.1) ' F1 Res58 HSW R3533 Horizontal Sidewall 5.8(84) 1/2 Recessed 16 x 20(4.9 x 6.1) Fl Res 58 RA3533 Horizontal Sidewall 5.8(84) 1/2 Recessed 14 x 26(4.3 x 7.9) HSWX www.reliablesprinkler.com Model Fl Res30 Residential Pendent Sprinkler&Models F2&FV Escutcheon SIN R3511 Technical Specifications Finishes Style:Pendent and Recessed Pendent (See Table N) Threads: 1/2"NPT or ISO7-1R1/27 Nominal K-Factor:3.0(43 metric) Temperature Ratings Max.Working Pressure:175 psi(12 bar) 155°F(68°C) 175°F(79°C) Material Specifications Thermal Sensor:3 mm glass bulb Recessed Escutcheons Sprinkler Frame:Brass Alloy F2 Recessed 1"c Button:Copper Alloy FV Recessed° Sealing Assembly:Nickel Alloy with PTFE ` Load Screw:Bronze Alloy Sprinkler Wrenches w Deflector:Bronze Alloy Model W2 Model GFR2(Recessed) Model FV escutcheons are not for use in positively pressurized ceiling plenums. Model F1Res30 Residential Pendent Sprinkler Components and Installation Dimensions Figure 1 2-1/4"(57mm) DIA. Face of fitting 1-15/16" to finished (49mm)DIA. ceiling 1/2"(13mm) +/-1/4"(6mm) Threads Wrench Flat i rr— • Sealing Assembly Iy 1 " ��� 2-1/4" - 1 � r IjI .i lilt Glass Bulb (57mm) r' , Load Screw 1/4"(6mm) Deflector 1-1/4"__._.. —(32mm)y 2-7/8"(72mm)DIA. Components Dimensions F2&FV Recessed Escutcheon Installation Model Fl Res30 Residential Pendent Sprinkler Hydraulic Design Criteria Table B Minimum Flow and Residual Pressure in Wet Pipe Systemst't Maximum Coverage Aream Flow Pressure Deflector to ft.x ft.(m x m) gpm(I/min) psi(bar) Ceiling Distance 12 x 12(3.7 x 3.7) 8(30) 7.0(0.48) 14 x 14(4.3 x 4.3) 10(38) 11.0(0.76) 1 to 4 inches 15 x 15(4.6 x 4.6) 12(45) 16.0(1.1) (25 to 100 mm) 16 x 16 (4.9 x 4.9) 13(49) 18.8(1.3) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1)the flow listed in the table above or(2)the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above,use the minimum required flow for the next larger max.coverage area listed. Bulletin 135 �''��'� Page 2 of 15 October 2018 www.reliablesprinkler.com Model F1Res49 Residential Sprinkler& Models Ft F2, & FV Escutcheons SIN R3516 Technical Specifications Finishes Style:Pendent and Recessed Pendent (See Table N) Threads:1/2"NPT or ISO7-1R1/2 „_ Nominal K-Factor:4.9(71 metric) Temperature Ratings Max.Working Pressure:175 psi(12 bar) 155°F(68°C) 175°F(79°C) Material Specifications Thermal Sensor:3 mm glass-bulb Recessed Escutcheons Fl Recessed " Sprinkler Frame:Brass Alloy - Button:Copper Alloy F2 Recessed FV Recessed` . Sealing Assembly:Nickel Alloy with PTFE Load Screw:Bronze Alloy - Sprinkler Wrenches Deflector:Bronze Alloy Model W2 Model GFR2(Recessed) *Model FV escutcheons are not for use in positively pressurized ceiling plenums. Model Fl Res49 Residential Pendent Sprinkler Components and Installation Dimensions Figure 2 2-1/4"(57mm) 2-1/4"(57mm) DIA. Face of fitting DIA. Face of fitting 1-15/16" to finished 1-15/16" to finished (49mm)DIA. ceiling (49mm)DIA. ceiling 5/8"(16mm) I 1/2"(13mm) +/-3/8"(9mm) +!-1/4"(6mm) 1 1r c ' _1 A 1r' 1-3/4"(44mm)+/- ' lif d 1-5l8"(41mm)+/- ip 1/4"(6mm) Fes- 1-1/4" -�-II I (32mm) 2-7/8"(72mm)DIA. -2-7/8"(72mm)DIA.- Dimensions Fl Recessed Escutcheon Installation F2&FV Recessed Escutcheon Installation Model FIRes49 Residential Pendent Sprinkler Hydraulic Design Criteria Table C Minimum Flow and Residual Pressure in Wet Pipe Systemst+i Maximum Coverage Area(2) Flow Pressure Deflector to ft.x ft.(m x m) gpm(I/min) psi(bar) Ceiling Distance 12 x 12(3.7 x 3.7) 13(49) 7.0(0,48) 14 x 14(4.3 x 4.3) 13(49) 7.0(0.48) 16 x 16(4.9 x 4.9) 13(49) 7.0(0.48) 1 to 4 inches (25 to 100 mm) 18 x 18(5.5 x 5.5) 17(64) 12.0(0.83) 20 x 20(6.1 x 6.1) 20(76) 16.7(1.15) 12 x 12(3.7 x 3.7) 15(57) 9.4(0.65) 14 x 14(4.3 x 4.3) 16(61) 10.7(0.74) 16 x 16(4.9 x 4.9) 17(64) 12.0(0.83) 4 to 8 inches (100 to 200 mm) 18 x 18(5.5 x 5.5) 19(72) 15.0(1.03) _ 20 x 20(6.1 x 6.1) 22(83) 20.2(1.39) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of:(1)the flow listed in the table above or(2)the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above,use the minimum required flow for the next larger max.coverage area listed. Bulletin 135 ReliablePage 3 of 15 October 2018 www.reliablesprinkler.com Model F1 Res58 Residential Pendent Sprinkler&Fl, F2, &FV Recessed Escutcheons SIN R3513 Technical Specifications Finishes Style:Pendent and Recessed Pendent (See Table N) Threads: 1/2"NPT or ISO7-1R1/2 Nominal K-Factor:5.8(84 metric) Temperature Ratings sr Max.Working Pressure:175 psi(12 bar) 155°F(68°C) 175°F(79°C) 1 --'„. Material Specifications Thermal Sensor:3 mm glass bulb Recessed Escutcheons Sprinkler Frame:Brass Alloy Fl Recessed Button:Copper Alloy F2 Recessed Sealing Assembly:Nickel Alloy with PTFE FV Recessed° i:. Load Screw:Bronze Alloy Deflector:Bronze Alloy Sprinkler Wrenches Model W2 Model GFR2(Recessed) Model FV escutcheons are not for use in positively pressurized ceiling plenums. Model FlRes58 Residential Pendent Sprinkler Components and Installation Dimensions Figure 3 2-1/4”(57mm) 2-1/4"(57mm) DIA. Face of fitting DIA. Face of fitting 1-15/16" to finished 1-15/16" to finished (49mm)DIA. ceiling (49mm)DIA. ceiling 5/8"(16mm) I 1/2"(13mm) +1-3/8"(9mm) +/-1/4"(6mm) to to (57) r r ��//// ' f Imm - liiM � � T 1-3/4"(44mm)+/- rr 1-5/8"(41 mm)+/ 1/4"(6mm) MI a 3/8"(9mm) 1 - .._._-1-1/4-----.. I I (32mm)— 2-7/8"(72mm)DIA.— –2-7/8"(72mm)DIA.-- Dimensions Fl Recessed Escutcheon Installation F2&FV Recessed Escutcheon Installation Model FlRes58 Residential Pendent Sprinkler Hydraulic Design Criteria Table D Minimum Flow and Residual Pressure in Wet Pipe Systems(') Maximum Coverage Areat2t Flow Pressure Deflector to ft.x ft.(m x m) gpm(I/min) psi(bar) Ceiling Distance 16 x 16(4.9 x 4.9) 16(61) 7.6(0.52) 18 x 18(5.5 x 5.5) 19(72) 10.8(0.75) 1 to 4 inches (25 to 100 mm) 20x20(6.1 x6.1) 22(83) 14.4(1.0) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1)the flow listed in the table above or(2)the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above,use the minimum required flow for the next larger max,coverage area listed. Bulletin 135 ��''��'� Page 4 of 15 October 2018 www.reliablesprinkler.com Model F1Res76 Residential Pendent Sprinkler& Fl, F2, & FV Escutcheons SIN R7618 Technical Specifications Finishes (See Table N) Style:Pendent and Recessed Pendent Threads:3/4"NPT or IS07-1 R3/4 Temperature Ratings 7.,.-4'.7- Nominal K-Factor:7.6(109 metric) 155°F(68°C) '� , ' Max.Working Pressure:175 psi(12 bar) 175°F(79°C) ,--- r Material Specifications Recessed Escutcheons - Thermal Sensor:3 mm glass bulb F1 Recessed Sprinkler Frame:Brass Alloy F2 Recessed _ Button:Copper AlloyFV Recessed* '' Sealing Assembly:Nickel Alloy with PTFE '� Load Screw:Bronze Alloy Sprinkler Wrenches Deflector:Bronze Alloy Model W2 Model GFR2(Recessed) *Model FV escutcheons are not for use in positively pressurized ceiling plenums. Model Fl Res76 Residential Pendent Sprinkler Components and Installation Dimensions Figure 4 2-1/4"(57mm) 2-1/4"(57mm) DIA. Face of fitting DIA. Face of fitting 1-15/16" to finished 1-15/16" to finished (49mm)DIA. ceiling (49mm)DIA. ceiling I 5/8"(16mm) I 1/2"(13mm) I +/-3/8"(9mm) +/-1/4"(6mm) (57)„ 411111° ///1iii ' //i mi,E, in hr _ r, 1-5/8"(41mm)+/- " 1-3/4"(44mm)+/- it 3/8"(9mm) 1/4"(6mm) - 1 --._.. - i 1-5/8" I 1 (44mm) 2-7/8"(72mm)DIA. 2-7/8"(72mm)DIA. - Dimensions F1 Recessed Escutcheon Installation F2&FV Recessed Escutcheon Installation Model Fl Res76 Residential Pendent Sprinkler Hydraulic Design Criteria Table E Minimum Flow and Residual Pressure in Wet Pipe Systemsl') Maximum Coverage Area Flow Pressure Deflector to ft.x ft.(m x m) gpm(I/min) psi(bar) Ceiling Distance 18 x 18(5.5 x 5.5) 21 (80) 7.6(0.52) 1 to 4 inches 20 x 20(6.1 x 6.1) 23(87) 9.2(0.63) (25 to 100 mm) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of;(1)the flow listed in the table above or(2)the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above,use the minimum required flow for the next larger max.coverage area listed. Bulletin 135 �e1i��'� Page 5 of 15 October 2018 www.reliablesprinkler.com Model Fl Res30 CCP Conical Concealed Pendent&Model FP Recessed Escutcheon Pendent SIN R3511 Sprinkler Finishes Technical Specifications (See Table N) Style:Conical Concealed Pendent and Recessed Pendent ,Temperature Ratings Threads: 1/2"NPT or ISO7-1R1/2 155°F(68°C) Nominal K-Factor:3.0(43 metric) Max.Working Pressure:175 psi(12 bar) Recessed Escutcheons/Cover Plates CCP Conical Concealed Plate 135°F(57°C)* � ` Material Specifications FP Recessed* Thermal Sensor:3 mm glass bulb Sprinkler Frame:Brass Alloy Sprinkler Wrenches Button:Copper Alloy Model GFR2 Sealing Assembly:Nickel Alloy with PTFE Load Screw:Bronze Alloy Deflector:Bronze Alloy *Note:Model FP escutcheons and CCP cover plates are not listed for use in positively pressurized ceiling plenums. Model FlRes30 CCP and FP Recessed Pendent Sprinkler Installation Dimensions Figure 5 2-5/8"(67mm) , 2-5/8"(67mm) DIA. DIA. 2-5/16" • 2-5116" (59mm)DIA. (59mm)DIA. Face of fitting i Face of fitting to finished - - to finished cr: ceiling ceiling 1-1/4"(32mm) 1-1/4"(32mm) - Y//�\1 J ` j ,� +/-1/4"(6mm) V//�/ � j/// —+l-1J4"(6mm) 15/16" 1"(25mm) / _(15/16"24mm ,.,,,,,u +/ 1/4"(6mm) 3-3/16"(78mm)DIA. 3-5/16"(84mm)DIA. CCP Recessed Escutcheon Installation FP Recessed Escutcheon Installation Model Fl Res30 CCP Pendent&FP Recessed Pendent Sprinkler Hydraulic Design Criteria Table F Minimum Flow and Residual Pressure in Wet Pipe Systems') Maximum Coverage Arean Flow Pressure ft.x ft.(m x m) gpm(I/min) psi(bar) Deflector to Ceiling Distance 12 x 12(3.7 x 3.7) 8(30) 7.0(0.48) 1/2 to 1 inch 14 x 14(4.3 x 4.3) 11 (38) 13.4(0.92) (13 to 25 mm) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of:(1)the flow listed in the table above or(2)the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above,use the minimum required flow for the next larger max.coverage area listed. 3. The sprinkler must be installed into a ceiling with the listed cover plate installed. Bulletin 135 ��';a�'� Page 6 of 15 October 2018 www.reliablesprinkler.com Model F1 Res49 CCP Conical Concealed Pendent&Model FP Recessed Escutcheon Pendent Sprinkler SIN R3516 Technical Specifications Finishes Style:Conical Concealed Pendent and (See Table N) Recessed Pendent Temperature Ratings Threads: 1/2"NPT or ISO7-1R1/2 155°F(68°C) Nominal K-Factor:4.9(71 metric) Max.Working Pressure:175 psi(12 bar) Recessed Escutcheons/Cover Plates Material Specifications CCP Conical Concealed Plate 135°F(57°C)` Thermal Sensor:3 mm glass bulb FP Recessed* - Sprinkler Frame:Brass Alloy Button:Copper Alloy Sprinkler Wrenches Sealing Assembly:Nickel Alloy with PTFE Model GFR2 - Load Screw:Bronze Alloy Deflector.Bronze Alloy • *Note:Model FP escutcheons and CCP cover plates are not for use in positively pressurized ceiling plenums. Model FlRes49 CCP&FP Recessed Pendent Sprinkler Installation Dimensions Figure 6 2-5/8"(67mm) j 2-5/8"(67mm) j DIA. DIA. 2-5/16" 2-5/16" 1— k (59mm)DlA./ (59mm)DIA. Face of fitting i Face of fitting to finished 1 f to finished ceiling ceiling 1-1/4"(32mm) .. 1-1/4"(32mm) +/-1/4"(6mm) r .., +/-1/4"(6mm) • / i.... j///,_ Y///_ /�/ _ 15/16" v.' _ 1"(25mm) - / (24mm) W„„ +/ 1/4"(6mm) j . , 3-3/16"(78mm)DIA. 3-5/16"(84mm)DIA. - CCP Recessed Escutcheon Installation FP Recessed Escutcheon Installation Model Fl Res49 CCP Pendent and FP Recessed Pendent Hydraulic Design Criteria Table G Minimum Flow and Residual Pressure in Wet Pipe Systems 1 Maximum Coverage Area(2) Flow Pressure ft.x ft.(m x m) gpm(I/min) psi(bar) Deflector to Ceiling Distance 14 x 14(4.3 x 4.3) 13(49) 7.0(0.48) 16 x 16(4.9 x 4.9) 14(53) 8.2(0.57) 1/2 to 1 inch 18 x 18(5.5 x 5.5) 18(68) 13.5(0.93) (13 to 25mm) 20x20(6.1 x6.1) 20(76) 16.7(1.15) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of:(1)the flow listed in the table above or(2)the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above,use the minimum required flow for the next larger max.coverage area listed. 3. The sprinkler must be installed into a ceiling with the listed cover plate installed. Bulletin 135 �';��'� Page 7 of 15 October 2018 www.reliablesprinkler.com Model F1 Res58 CCP Conical Concealed Pendent&Model FP Recessed Escutcheon Pendent Sprinkler SIN R3513 Technical Specifications Finishes Style:Conical Concealed Pendent and (See Table N) Recessed Pendent Temperature Ratings t« Threads:1/2"NPT or ISO7-1R1/2 155°F(68°C) Nominal K-Factor:5.8(84 metric) Max.Working Pressure:175 psi(12 bar) Recessed Escutcheons/Cover Plates Material Specifications CCP Conical Concealed Plate 135°F(57°C)* �- • FP Recessed* ,:,#-v,„ Thermal Sensor:3 mm glass bulb Sprinkler Frame:Brass Alloy Sprinkler Wrenches 1: Button:Copper Alloy Model GFR2(Recessed) Sealing Assembly:Nickel Alloy with PTFE Load Screw:Bronze Alloy Deflector:Bronze Alloy *Note:Model FP escutcheons and CCP cover plates are not for use in positively pressurized ceiling plenums. Model Fl Res58 CCP and FP Recessed Pendent Sprinkler Installation Dimensions Figure 7 2-5/8'(67mm) _ _ �2-5/8"(67mm) DIA. DIA. 2-5/16" J �— 2-5/16" (59mm)DIA./ (59mm)DIA. Faceof fittingFace of fitting to finished I -_ to finished ceiling 1-1/4"(32mm) _ITfr 1-1/4"(32mm) - r +/-1/4"(6mm) ,.. +/-1/4"(6mm)___ ' r / 15/16" _ 1"(25mm) (24mm) a 1 +/-1/4"(6mm) 3-3/16"(78mm)DIA. - 3-5/16"(84mm)DIA. - CCP Recessed Escutcheon Installation FP Recessed Escutcheon Installation Model Fl Res58 CCP Pendent&FP Recessed Pendent Hydraulic Design Criteria Table H Minimum Flow and Residual Pressure in Wet Pipe Systems') Maximum Coverage Area12) Flow gpm Pressure psi Deflector to Ceiling ft.x ft.(m x m) (I/min) (bar) Distance 16 x 16(4.9 x 4.9) 16(61) 7.6(0.52) 18 x 18(5.5 x 5.5) 19(72) 10.8(0.75) 1/2 to 1 inch (13 to 25 mm) 20x 20(6.1 x 6.1) 22(83) 14.4(1.0) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of:(1)the flow listed in the table above or(2)the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above,use the minimum required flow for the next larger max.coverage area listed. 3. The sprinkler must be installed into a ceiling with the listed cover plate installed. Bulletin 135 ������'� Page 8 of 15 October 2018 www.reliablesprinkler.com Model F1 Res76 CCP Conical Concealed Pendent and Model FP Recessed Escutcheon Pendent Sprinkler SIN R7618 Technical Specifications Finishes Style:Conical Concealed Pendent and (See Table N) Recessed Pendent Threads:3/4"NPT or ISO7-1 R3/4 Temperature Ratings Nominal K-Factor 7.6(109 metric) 155°F(68°C) Max.Working Pressure:175 psi(12 bar) Recessed Escutcheons/Cover Plates Material Specifications CCP Conical Concealed Plate 135°F(57°C)* Thermal Sensor.3 mm glass bulb FP Recessed* - Sprinkler Frame:Brass Alloy Button:Copper Alloy Sprinkler Wrenches Sealing Assembly:Nickel Alloy with PTFE Model GFR2(Recessed) Load Screw:Bronze Alloy Deflector:Bronze Alloy *Note:Model FP escutcheons and CCP cover plates are not for use in positively pressurized ceiling plenums. Model F1 Res76 CCP and FP Recessed Pendent Sprinkler Installation Dimensions Figure 8 2-5/8"(67mm) 2-5/8"(67mm) DIA. DIA. 2-5/16" � 2-5/16" (59mm)DIA. 1 (59mm)DIA. Face of fitting Face of fitting ' to finished - to finished J7 ceiling ceiling 1.1 1-1/4"(32mm) 1-1/4"(32mm)kma +/ 1/4"(6mm) +/-1/4"(6mm) _ 1"(25mm) 15/16" +/-1/4"(6mm) (24mm) ...... . .. .... 3-3/18"(78mm)DIA. - 3-5/16"(84mm)DIA. CCP Recessed Escutcheon Installation FP Recessed Escutcheon Installation Model Fi Res76 CCP Pendent&FP Recessed Pendent Hydraulic Design Criteria Table I Minimum Flow and Residual Pressure in Wet Pipe Systemse') Maximum Coverage Areas Flow Pressure Deflector to Ceiling Distance ft.x ft.(m x m) gpm(I/min) psi(bar) 16 x 16(4.9 x 4.9) 21 (80) 7.6(0.52) 18 x 18(5.5 x 5.5) 22(83) 8.4(0.58) 1/2 to 1 inch (13 to 25 mm) 20 x20(6.1x 6.1) 25(95) 10.8(0.75) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of:(1)the flow listed in the table above or(2)the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above,use the minimum required flow for the next larger max.coverage area listed. 3. The sprinkler must be installed into a ceiling with the listed cover plate installed. Bulletin 135 ��';a�'� Page 9 of 15 October 2018 www.reliablesprinkler.com Model F1Res44 Horizontal Sidewall Sprinkler&Models FV&F2 Recessed Escutcheon SIN R3531 Finishes Technical Specifications (See Table N) Style:Sidewall and Recessed Sidewall Threads: 1/2"NPT or ISO7-1R1/2 Temperature Ratings Nominal K-Factor:4.4(63 metric) 155°F(68°C) Max.Working Pressure:175 psi(12 bar) 175°F(79°C) _ " Material Specifications Recessed Escutcheons Thermal Sensor:3 mm glass bulb F2 Recessed Sprinkler Frame:Brass Alloy FV Recessed k` Button:Copper Alloy i - SealingAssembly:Nickel Alloywith PTFE Sprinkler Wrenches ' Y 'a , Load Screw:Bronze Alloy Model W2 . Deflector:Bronze Alloy Model GFR2(Recessed) Model Fl Res44 Horizontal Sidewall Sprinkler Installation Dimensions Figure 9 Face of fitting to finished wall 2"(51mm) 1/2"(13mm) ,A +1-1/4"(6mm) +/-1/4"(6mm) IdA 2-1/2"(64mm) 21/4" 1-15/16" I 7.-,ik Top of Deflector Down from 111111.411DIA. DIA. 1111 fits==iillIA 1 (Ceiling to be 100 to 150 mm�)or 6"to her 4"to 82" (57mm) (49mm) - - b (150 to 300 mm)Based on 5/16"_ Hydraulic Calculations 1/2"(13mm) (8mm) Dimensions F2&FV Recessed Escutcheon Installation Model F1Res44 Horizontal Sidewall Sprinkler Hydraulic Design Criteria Table J Minimum Flow and Residual Pressure in Wet Pipe Systems') Maximum Coverage Area(2) Flow Pressure Deflector to ft.x ft.(m x m) gpm(I/min) psi(bar) Ceiling Distance 12 x 12(3.7 x 3.7) 12(45) 7.5(0.52) 14 x 14(4.3 x 4.3) 14(53) 10.2(0.70) 15 x 15(4.6 x 4.6) 15(57) 11.6(0.80) 4 to 6 inches 16 x 16(4.9 x 4.9) 16(61) 13.3(0.92) (100 to 150 mm) 16x18(4.9x5.5) 18(68) 16.8(1.16) 16x20(4.9 x6.1) 23(87) 27.4(1.89) 18x18(5.5x5.5) 19(72) 18.7(1.29) 12 x 12(3.7 x 3.7) 14(53) 10.2(0.7) 14 x 14(4.3 x 4.3) 16(61) 13.2(0.91) 15 x 15(4.6 x 4.6) 16(61) 13.2(0.91) 6 to 12 inches 16 x 16(4.9 x 4.9) 17(64) 15.0(1.03) (150 to 300 mm) 16 x 18(4.9 x 5.5) 20(76) 20.7(1.43) 16 x 20(4.9 x 6.1) 23(87) 27.4(1.89) Notes: - 1. For NFPA 13 installations the flow per sprinkler must be the greater of:(1)the flow listed in the table above or(2)the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above,use the minimum required flow for the next larger max.coverage area listed. Bulletin 135 liaifflPage 10 of 15 October 2018 www.reliablesprinkler,com Model Fl Res44 SWC Conical Concealed Horizontal Sidewall Sprinkler SIN R3531 Technical Specifications Finishes Style:Conical Concealed Sidewall (See Table N) Threads: 1/2"NPT or ISO 7-1 R1/2 A, Nominal K-Factor:4.4(63 metric) Temperature Ratings Max.Working Pressure:175 psi(12 bar) 155°F(68°C) 175°F(79°C)(') 4,i"' Material Specifications _--- Thermal Sensor.3 mm glass-bulb Cover Plates Sprinkler Frame:Brass Alloy SWC Conical Concealed Platel2l - Button:Copper Alloy SWC-2(Slotted)Conical Concealed Plate131 Sealing Assembly:Nickel Alloy with PTFE Load Screw:Bronze Alloy Sprinkler Wrenches Deflector:Bronze Alloy Model GFR2 SWC-2 S . Note: (1)Not for installation where the maximum ceiling temperature exceeds 100°F due to cover plate temperature rating. (2)135°F SWC Conical Concealed Plate for 155°F(68°C)sprinklers (3)135°F SWC-2(Slotted)Conical Concealed Plate for 175°F(79°C)sprinklers Model FlRes44 SWC Conical Concealed Horizontal Sidewall Sprinkler and Installation Dimensions Figure 10 1-1/4"(32mm) 2"(51mm) +/-1/4"(6mm) ri +1-1/4"(6mm) Face of feting to fnished wall 2-1/2"(64mm) - Top of Deflector Down 2-5/8" 2-5/16" 35/16" Nilke )( ) __ 11111 -_ from C(Ing to t Either ( ) (67mm 58mm 84mm DIA. DIA. �' 4"to 6" 100mm to DIA. I' (150 m)to 3"to 12)u 5/16" (150mm to 300mm) (8mm)y Based on Hydraulic Calculations rli 1 " 4 (41mm518 ) Dimensions SWC&SWC-2 Concealed Cover Plate Installation Model F1Res44 SWC Conical Concealed Horizontal Sidewall Sprinkler Hydraulic Design Criteria Table K Minimum Flow and Residual Pressure in Wet Pipe Systeme') Ordinary Temperature Rating Intermediate Temperature Rating Maximum Coverage Area1�1 155°F(68°C) 175°F(79°C) Deflector to Ceiling ft.x ft.(m x m) Flow Pressure Flow Pressure Distance gpm(I/min) psi(bar) gpm(I/min) psi(bar) 12 x 12(3.7 x 3.7) 13(49) 8.7(0.60) 14(53) 10.2(0.7) 14 x 14(4.3 x 4.3) 14(53) 10.2(0.7) 14(53) 10.2(0.7) 15 x 15(4.6 x 4.6) 16(61) 13.2(0.91) -- -- 4 to 6 inches 16x16(4.9x4.9) 17(64) 15.0(1.03) -- -- (100to150mm) 16x18(5.5x5.5) 19(72) 18.7(1.31) -- -- 16x20(4.9x6.1) 23(87) 27.4(1.89) -- -- 12x 12(3.7x3.7) 14(53) 10.2(0.7) -- -- 14x 14(4.3x4.3) 15(57) 11.7(0.81) -- -- 15 x 15(4.6 x 4.6) 17(64) 15.0(1.03) -- -- 6to12inches (150 to 300 mm) 16 x 16(4.9 x 4.9) 18(68) 16.8(1.16) -- -- 16x18(4.9x5.5) 20(76) 20.7(1.43) -- -- Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of:(1)the flow listed in the table above or(2)the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above,use the minimum required flow for the next larger max.coverage area listed. Bulletin 135 IEBEEPage 11 of 15 October 2018 www.reliablesprinkler.com Model F1 Res58 Horizontal Sidewall Sprinkler&Models F2&FV Recessed Escutcheon SIN R3533 Technical Specifications Finishes Style:Sidewall and Recessed Sidewall (See Table N) Threads: 1/2"NPT or IS07-1 R1/2 Nominal K-Factor:5.8(84 metric) Temperature Ratings , Max.Working Pressure:175 psi(12 bar) 155°F(68°C) ,,c;< _ 175°F(79°C) / �'u tM� ,,k., Material Specifications tl Thermal Sensor:3 mm glass bulb Recessed Escutcheons n � ' . Sprinkler Frame:Brass Alloy F2 Recessed i` ` Button:Copper Alloy FV Recessed "` _ Sealing Assembly:Nickel Alloy with PTFE Load Screw:Bronze Alloy Sprinkler Wrenches Deflector:Bronze Alloy Model W2 Model GFR2(Recessed) Model Fl Res58 Residential Horizontal Sidewall Sprinkler Installation Dimensions Figure 11 Face of fitting to finished wall 2"(51mm) 1/2"(13mm) ►A +/-1/4"(6mm) +/-1/4"(6mm) ir- A 2-1/2"(64mm) 11r 2-1/4" 1-15/16" I Top of Deflector Down from 57mm) (49mm) I Ceiling to be Either 4"to 6" 111. mm."I ( DIA. DIA. I 1 I (100 to 150 mm)or 6"to 12" ��� (150 to 300 mm)Based on b 5/16" Hydraulic Calculations 1/2"(13mm) (8mm) Dimensions F2&F1/Recessed Escutcheon Installation Model Fl Res58 Horizontal Sidewall Sprinkler Hydraulic Design Criteria Table L Minimum Flow and Residual Pressure in Wet Pipe Systems') Maximum Coverage Aream Flow Pressure Deflector to ft.x ft.(m x m) gpm(I/min) psi(bar) Ceiling Distance 12 x 12(3.7 x 3.7) 16(61) 7.6(0.52) 14 x 14(4.3 x 4.3) 18(68) 9.7(0.66) 15 x 15(4.6 x 4.6) 19(72) 10.7(0.74) 4 to 6 inches 16 x 16(4.9 x 4.9) 21 (80) 13.2(0.91) (100 to 150 mm) 16x18(5.5x5.5) 25(95) 18.6(1.28) 16x20(4.9x6.1) 29(110) 25.0(1.72) 12x12(3.7x3.7) 22(83) 14.4(1.0) 14 x 14(4.3 x 4.3) 22(83) 14.4(1.0) 15 x 15(4.6 x 4.6) 24(91) 17.1 (1.18) 6 to 12 inches (150 to 300 mm) 16 x 16(4.9 x 4.9) 26(98) 20.1 (1.39) 16 x 18(4.9 x 5.5) 31 (117) 28.6(1.97) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of:(1)the flow listed in the table above or(2)the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. • 2. For coverage area dimensions less than those listed above,use the minimum required flow for the next larger max.coverage area listed. Bulletin 135ringragra Page 12 of 15 October 2018 www.reliablesprinkler.com Model FlRes58 HSWX Horizontal Sidewall Sprinkler& Models F2& FV Recessed SIN RA3533 Escutcheon Finishes Technical Specifications (See Table N) Style:Sidewall and Recessed Sidewall Threads:1/2"NPT or ISO7-1R1/2 Temperature Ratings Nominal K-Factor.5.8(84 metric) 155°F(68°C) ,%.,,,1 x. Max.Working Pressure:175 psi(12 bar) 175°F(79°C) Material Specifications Recessed Escutcheons Thermal Sensor:3 mm glass bulb F2 Recessed rt; , Sprinkler Frame:Brass Alloy FV Recessed Button:Copper Alloyk Sealing Assembly:Nickel Alloy with PTFE Sprinkler Wrenches Load Screw:Bronze Alloy Model W2 Deflector:Bronze Alloy Model GFR2(Recessed) Model F1 Res58 HSWX Residential Horizontal Sidewall Sprinkler Installation Dimensions Figure 12 Face of fitting to finished wall 2-1/2"(64mm) 1/2"(13mm) +/-1/4"(6mm) +1-1/4"(6mm) 3"(76mm) - I/ 2-1/4" 1-15/16" Top of Deflector Down From ci (57mm) (49mm) — DIA. DIA. `�r� i' (150 to 300 mm)Based on . b 5/16" ll Hydraulic Calculations 1� I � 1/2"(13mm) (8mm) Dimensions F2&FV Recessed Escutcheon Installation Model Fl Res58 HSWX Horizontal Sidewall Sprinkler Hydraulic Design Criteria Table M Minimum Flow and Residual Pressure in Wet Pipe Systemsm Maximum Coverage Area121 Flow Pressure Deflector to ft.x ft.(m x m) gpm(I/min) psi(bar) Ceiling Distance 18x20(5.5x6.1) 30(114) 26.8(1.85) 20x20(6.1x 6.1) 30(114) 26.8(1.85) 16 x 22(4.9 x 6.7) 33(125) 32.4(2.23) 4 to 6 inches (100 to 150 mm) 16 x 24(4.9 x 7.3) 38(144) 42.9(2.96) 14 x 26(4.3 x 7.9) 42(160) 52.4(3.63) 18x20(5.5x6.1) 35(133) 36.4(2.51) 16 x 22(4.9 x 6.7) 38(144) 42.9(2.96) 6 to 12 inches 16 x 24(4.9 x 7.3) 42(160) 52.4(3.61) (150 to 300 mm) 14 x 26(4.3 x 7.9) 46(174) 62.9(4.34) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of:(1)the flow listed in the table above or(2)the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above,use the minimum required flow for the next larger max.coverage area listed. • Bulletin 135 ReliablePage 13 of 15 October 2018 www.reliablesprinkler.com Finishes Table N Standard Finishes Special Application Finishes F1,F2.FV,FPS, CCP,SWC(Conical) Fl,F2.FV,FPS, CCP,SWC(Conical) Sprinkler<,� Escutcheons Cover Plates( Sprinkler�'� Escutcheons Cover Plates to Bronze Brass -- Bright Brass Bright Brass Bright Brass Chrome Plated Chrome Plated Chrome Plated Dull Chrome Dull Chrome Dull Chrome White White White Paint Black Black Black Paint Polyester(2) Polyester Polyester(2) Polyester Custom Color Custom Color Custom Color Paint Polyester Polyester Electroless Nickel PTFE(2) Notes: (1)Paint or any other coating applied over the factory finish will void all approvals and warranties. (2)cULus Listed Corrosion Resistant. (3)The Model FP escutcheon assembly consists of an unfinished galvanized cup with a finished escutcheon ring. Installation Models Fl Res sprinklers are to be installed as shown in this A'leak tight"sprinkler joint can be obtained with the following bulletin. Model Fl, F2, FV,and FP recessed escutcheons torque: are the only recessed escutcheons to be used with Model F1Res sprinklers. Not all F1Res sprinklers may be used with • 1/2"NPT and IS07-1R1/2: 8-18 ft-lbs(11 -24 N-m) all recessed escutcheons offered.Confirm listing of escutch- • 3/4" NPT and ISO7-1 R314: 14-20 ft-lbs(19-27 N-m) eon type for use with individual sprinklers. Use of any other recessed escutcheon will void all approvals and warranties. Do not tighten sprinklers over maximum recommended torque. This may cause leakage or impairment of the sprinklers. For installing Model F1Res sprinklers,use only the Model Do not install any glass bulb sprinklers where the bulb is W2 sprinkler Wrench;for installing Models Fl Res Recessed cracked or there is a loss of liquid from the bulb. Pendent,Sidewall,Conical Concealed Pendent(CCP), and Sidewall Concealed(SWC and SWC-2)sprinklers use only Glass bulb sprinklers have orange bulb protectors to mini- the Model GFR2 sprinkler wrench. Use of wrenches other than mize bulb damage during shipping, handling and installation. those specified may damage these sprinklers. Remove this protection at the time the sprinkler system is placed in service. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when protectors are in place. Remove protectors by undoing the clasp by hand. Do not use tools to remove the protectors. Maintenance Reliable Model F1Res Sprinklers should be inspected and the } sprinkler system maintained in accordance with NFPA 25, 13, Model W2 13D,and 13R,as well as the requirements of any Authorities Having Jurisdiction. Model GFR2 Prior to installation,sprinklers should remain in the original Installation of Fl Res sprinklers in a wall or ceiling will require cartons and packaging until used.This will minimize the a hole diameter of 2-1/4" (57 mm)for Fl or F2 recessed potential for damage to sprinklers that could cause improper escutcheons;or 2-5/8" (67 mm)for FP recessed escutcheons, operation or non operation. CCP,SWC, and SWC-2 cover plates. Do not clean sprinklers with soap and water, ammonia liquid Install Fl Res HSW sprinklers with a ceiling to deflector dis or any other cleaning fluids. Remove dust by gentle vacuum- tance that complies with the hydraulic design criteria tables in ing without touching the sprinkler. - this bulletin.The flow arrow on deflector must point away from near wall and"Top"marking must face the ceiling. Replace any sprinkler which has been painted(other than factory applied). Properly installed CCP, SWC,and SWC-2 cover plates will have an air gap that is required for proper operation, do not seal the gap or paint the cover plates. Bulletin 135 i � Page 14 of 15 October 2018 www.reliablesprinkler.com Replace any sprinkler which has been damaged,where cracks are observed in the glass bulb,or when liquid has been lost from the glass bulb. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Failure to properly maintain sprinklers may result in inadver- tent operation or non-operation during a fire event. Listings &Approvals - Listed by Underwriters Laboratories Inc.and UL Certified for Canada(cULus) - Guarantee For Reliable Automatic Sprinkler Company guarantee,terms, and conditions,visit www.reliablesprinkler.com. Patents For patents applicable to products contained in this technical bulletin, please visit www.r-s.co Ordering Information Specify the following when ordering: Sprinkler • Model(See Table A) • Temperature Rating • Threads(NPT or 1507-1) • Finish (See Table N) Escutcheon or Cover Plate • Model • Finish(See Table N) Sprinkler Wrench • Model W2(Pendent and HSW) • GFR2(Recessed and Concealed) co co 0 a) m a) a) C) Z a Bulletin 135 ��';��'� Page 15 of 15 October 2018 www.reliablesprinkler.com Bulletin 157 Rev.M .. Reimbid Model F3QR56 Dry c K5.6 (80 metric) D Quick-Response, o Standard Spray Sprinklers Features 1. Available in the following configurations: • Pendent with standard escutcheon • Pendent with Model HB extended escutcheon . _ • Pendent with Model FP recessed escutcheon • Pendent with Model Fl recessed escutcheon It • Concealed Pendent with Model CCP cover plate • Horizontal Sidewall with Standard escutcheon Tom,x 1. • Horizontal Sidewall with Model HB extended es- cutcheon Pendent Pendent/HB • Horizontal Sidewall with Model FP recessed es- (See Fig. 1) (See Fig. 2) cutcheon (FM Standard Response) • Horizontal Sidewall with Model Fl recessed es- cutcheon a' (FM Standard Response) 2. Available with 1" NPT, IS07-1R1, 3/4" NPT, or IS07- 1 R3/4 inlet fitting. 3. 3/4" NPT inlet fittings permit replacement of older 3/4" A . ; inlet dry sprinklers without changing to a larger sprin- kler fitting. 4 4. Sprinklers, escutcheons, and cover plates are avail able in a wide variety of standard and special appli- Recessed FP Pendent Concealed cation finishes. (See Fig. 3) (See Fig.4) 5. White polyester, black polyester, and Electroless Nickel PTFE (ENT) finish sprinklers are cULus Listed as Corrosion Resistant. 6. Available with cULus Listed 250 psi (17.2 bar) pres- sure rating for Dry Pendent and select HSW configu- rations. FM Approved for 175 psi (12 bar). .. Product Description Model F3QR56 Dry sprinklers are quick-response, stan- dard coverage sprinklers with a nominal K-Factor of 5.6(80 Recessed F1 Pendent Horizontal Sidewall metric). Available in Dry Pendent or Dry Horizontal Sidewall (See Fig. 5) (See Fig.6) configurations, Model F3QR56 Dry sprinklers all use a 3 mm glass bulb operating element. See the Temperature Rat- ings table in this Bulletin for available temperature ratings. V Model F3QR56 Dry sprinklers are intended for installation '_- f on wet-pipe, dry-pipe, or preaction sprinkler systems in ac- Fu^" cordance with NFPA 13, FM Property Loss Prevention Data Sheets, and other applicable installation standards. Model F3QR56 Dry sprinklers are available with a vari- Horizontal Sidewall/HB ety of escutcheon options as illustrated in Figs. 1 through (See Fig. 7) 3 and Figs. 5 through 9. In addition, Model F3QR56 Dry Pendent sprinklers are also available with the Model CCP .2 _�: conical concealed cover plate as illustrated in Fig. 4. Avail " able sprinkler, escutcheon, and cover plate finishes are identified in the Finishes table in this Bulletin. The Model Fl 4*"': ' escutcheon, Model FP escutcheon, and Model CCP cover _. • plate are the only recessed escutcheons and cover plate listed for use with Model F3QR56 Dry sprinklers; the use of Recessed FP Recessed Fl any other recessed escutcheon or cover plate with Model Horizontal Sidewall Horizontal Sidewall F3QR56 Dry sprinklers will void all guarantees, warranties, (See Fig. 8) (See Fig. 9) listings and approvals. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Inlet fittings are available with 1" NPT, ISO 7-1R1,3/4" NPT, See the Available Configurations, Listings, and Approvals or IS07-1 R3/4 threads. Sprinklers with 3/4" NPT and IS07- table in this Bulletin for further information on Model F3QR56 1 R3/4 inlet fittings are intended primarily for replacement of Dry sprinklers. existing 3/4"or IS07-1 R3/4 inlet dry sprinklers, but may also be used in new installations. Available Configurations, Listings, and Approvals Available Sprinkler Sprinkler Escutcheon or Listings and Inlet Identification Model Cover Plate Length Approvalst') Threads Number (See Figs. 1-9) (SIN) Standard 2" to 36" Escutcheon (50 to 900 mm) HB Extended Escutcheon Fl Recessed cULus, NYC 3/4" NPT or Escutcheon 3-1/2" to 36" IS07-1 R3/4 (90 to 900 mm) FP Recessed Escutcheon F3QR56 Dry CCP Cover Plate Pendent R5714 Standard 2" to 48" Escutcheon (50 to 1200 mm) HB Extended Escutcheon 1" NPT Fl Recessed cULus, FM, NYC or Escutcheon 3-1/2" to 48" IS07-1R1 (90 to 1200 mm) FP Recessed Escutcheon CCP Cover Plate Standard 2" to 48" Escutcheon (50 to 1200 mm) HB Extended Escutcheon cULus12>, NYC(2) 3/4" NPT or Fl Recessed 3-1/2" to 48" 1507-1R3/4 Escutcheon (90 to 1200 mm) FP Recessed F3QR56 Dry Escutcheon Horizontal R5734 Sidewall Standard 2" to 48" Escutcheon (50 to 1200 mm) cULus12>, FM13>, NYC(2) HB Extended 3-1/2" to 48" Escutcheon (90 to 1200 mm) 1" NPT or Fl Recessed 1507-1R1 Escutcheon 3-1/2" to 48" cULus12>, FP Recessed (90 to 1200 mm) FM(3)14>, NYC(2) Escutcheon (”For available temperature ratings and finishes see the Temperature Ratings and Finishes tables, respectively,in this Bulletin. I (2)cULus Listing and NYC for Light Hazard and Ordinary Hazard only. (3)FM Approved for Light Hazard only. (4)Model F3QR56 Dry Horizontal Sidewall with Model Fl or Model FP recessed escutcheon are FM Approved as Standard Response. 2. • Patents Model F3QR56 Dry series sprinklers may be covered by one or more of the following patents: US Patent No. 5,775,431 US Patent No. 5,967,240 Listing and Approval Agencies See the Available Configurations, Listings, and Approvals table in this Bulletin for listings and approvals applicable to each available configuration. 1. Listed by Underwriters Laboratories, Inc. and UL Certified for Canada (cULus) 2. Certified by FM Approvals (FM) 3. Permitted in New York City based on UL Listing per Local Law 33/2007 (NYC) Technical Data Nominal K-Factor: 5.6 gpm/psi''2 (80 L/min/bar't2) Sprinkler Listing or Approval Deflector to Ceiling Distance Maximum Working Pressure F3QR56 Dry cULus,NYC -- 250 psi(17.2 bar) Pendent FM -- 175 psi(12 bar) 4"to 6" 250 psi(17.2 bar) F3QR56 Dry cULus, NYC Horizontal Sidewall 6"to 12" 175 psi(12 bar) FM -- 175 psi(12 bar) Temperature Glass Bulb Sprinkler Cover Plate Maximum Ceiling Listings and Classification Color Temperature Rating Temperature Rating Temperature Approvals(') Orange 135°F(57°C) Ordinary 135°F(57°C) 100°F(38°C) cULus, FM,NYC Red 155°F(68°C) Intermediate Yellow 175°F(79°C) 165°F(74°C) 150°F(66°C) cULus, NYC Intermediate Green 200°F(93°C) 165°F(74°C) 150°F(66°C) cULus, FM,NYC None 225°F(107°C) cULus,FM(2), NYC High Blue 286°F(141°C) 165°F(74°C) 150°F(66°C) cULus, NYC (')For listed and approved sprinkler,escutcheon,and inlet configurations see the Available Configurations,Listings,and Approvals table in this Bulletin. 121 High temperature classification is FM Approved with Standard and Model HB escutcheons only. Finishes Component Sprinkler Escutcheono1 Cover Plate Bronze Brass(3) White Paint Standard Finishes White Polyester(2) White Polyester Chrome Chrome Chrome Electroless Nickel PTFE(2) Satin Chrome Electroless Nickel PTFE Black Paint Special Application Finishes Black Polyester(2) Black Polyester Custom Color Paint Customer Color Polyester Custom Color Polyester Black Plating (1)Standard and Model HB escutcheons are supplied with both the can and escutcheon finished.Model Fl escutcheons are supplied with both the collar and escutcheon finished.Model FP escutcheons are supplied with the escutcheon finished;the cup is galvanized steel with no further finish. (2)cULus Listed as a Corrosion Resistant Sprinkler. 13)Brass finish available for standard,Model Fl,and Model FP escutcheons only. 3. I Model F3QR56 Dry Pendent Sprinkler with Standard Escutcheon (SIN R5714) "A"Dim. 2"to 48"(51mm to 1219mm)in 1/4"(6mm)increments for 1"connections or 2"to 36"(51mm to 914mm)in 1/4"(6mm)increments for 3/4"connections r—� }— s-1 li 11 I if il `\1 -- — �LTft --j L-- 1_---JI r) i A L_ System Fitting Inlet Fitting 2-1/8" i-. [54mm] Dia. "A" Dimension Hole in Ceiling 1-1/2" [38 mm] 1-21/32" Dia. ir- Total Adjustment [42 mm] i--------7 1-1/4" [32 mm] Sprinkler Can --- 1 Ceiling i Escutcheon Adjustment Escutcheon -- -- i 1/4" [6 mm] Ceiling i I -7 Escutcheon ICeiling ' 1 1 Adjustment Nominal 1 ! J Escutcheon , l. "111 ' fr Position 14 1/4"[6 mm] Protrusion at Nominal Escutcheon Position 1 1-5/8" 3" [76 mm] [41 mm] 153FG01-G DIA. Fig. 1 Note:The sprinkler can protrudes 14"when escutcheon is in nominal position. Escutcheon adjustment provides'/4"(-6mm)to+1'/a" (+32mm)"A" dimension adjustment range. Sprinkler Guard: Model C2 4. 1 Model F3QR56 Dry Pendent Sprinkler with Model HB Extended Escutcheon (SIN R5714) "A"Dim. 31/2"to 48"(89mm to 1219mm)in 1/4"(6mm)increments for 1"connections or 31/2"to 36"(89mm to 914mm)in 1/4"(6mm)increments for 3/4"connections F-==1-HifFtr- - --'--- IF -=-- 7T- _ I11h _1 1_ III \ �III� I I 1 �' - _ �I �-ter r-- — -� f ) - System Fitting 1 .viN 2-1/2"[64 mm]Dia. _______a_o±___11....jN Inlet Fitting Hole in Ceiling "A"Dimension3-1/2"[89 mm] Escutcheon Dia. 1/2"[12.5mm] 1 Escutheon Adjustment Ceiling 1"[25 mm]Total »> = Escutcheon Adjustment Escutcheon — / \ f • t " mm] Escutheon 1/2 [12.5Adjustment Nominal Position Sprinkler Can of Escutcheon 1-1/4"[32 mm] 111 Protrusion at V' 1-5/8" Nominal Escutcheon Position ` / , [41 mm] 157FG02B 2-3/16"[56 mm]Dia. -•r I.– Fig.2 Note: The sprinkler can protrudes 1'A"when escutcheon is in nominal position. Escutcheon adjustment provides'/"(-12.7mm)to+1/2"(+12.7mm) "A"dimension adjustment range. Sprinkler Guard: Model C2 5. I Model F30R56 Dry Pendent Sprinkler with Model FP Recessed Escutcheon (SIN R5714) "A"Dim. 31/2"to 48"(89mm to 1219mm)in 1/4"(6mm)increments for 1"connections or 31/2"to 36"(89mm to 914mm)in 1/4"(6mm)increments for 3/4"connections r-Z 7 Ir----- ----1 i---+il I- --di i� I .hh I I I ��;�$ ---' d - - —I — i— ill — `< it t\ mil I I 1111111 i iI II11====1411----J `-' L---tL- - J I r l Li L_ 1111=111111. i System Fitting i 3 Inlet Fitting I 2-1/2" [64 mm] Dia. -..,, I •-i Hole in Ceiling "A" Dimension I 2-9/32" [58 mm] Dia. -.. J I - Nominal Sprinkler Escutcheon I Cup Position l 1 • Escutcheon 1 1 z - 40 i Ceiling I Ceiling i 1/4 [6 mm] i Escutcheon Adjustment 1/4" [6 mm] Escutcheon Adjustment 3-7/32' --., [82 mm] Dia. 10.- 1/2" [12 mm] Total Escutcheon Adjustment 153FG02-F Fig. 3 Note:Do not install the Model F3QR56 Dry Pendent sprinkler with the Model FP escutcheon in ceilings which have positive pressure in the space - above. 6. • I Model F3QR56 Dry Pendent Sprinkler with Model CCP Cover Plate (SIN R5714) "A"Dim. 31/2"to 48"(89mm to 1219mm)in 1/4"(6mm)increments for 1"connections or 3'/2"to 36"(89mm to 914mm)in 1/4"(6mm)increments for 3/4"connections rz �--i --- ---- --- -li 7 I It h1II I `K 1111 ,,,,, 1 I In,: 1 \1-=--141t, --J m� )-- L---j 1 _1 rj 1=-1 t L- II--.-I J System Fitting Inlet Fitting IN 2-1/2'[64 mm]Dia. IIII Hole in Ceiling 'A'Dimension 2-9/32'[58 mm]Dia. III Nominal Sprinkler Cover Plate Cup Assembly • Position �i j Model CCP 1/2 Cover Plate Assembly — — Ceiling n (Adjustment Limited to 3!8'[10 mm]) r - � � , 1 ,. Ceiling i 3/16'[5 mm] t A -,Q� gmllitar Cover Plate Adjustment 3/16'[5 mm] Cover Plate Adjustment 3-5/16" [84 mm] Dia. 3/8'[10 mm] 153FG03-F Total Cover Plate Adjustment Fig.4 I Note:Do not install the Model F3QR56 Dry Pendent sprinkler with the Model CCP cover plate in ceilings which have positive pressure in the space - above. 7. 1 Model F3QR56 Dry Pendent Sprinkler with Model Fl Recessed Escutcheon (SIN R5714) "A"Dim. 31/2"to 48"(89mm to 1219mm)in 1/4"(6mm)increments for 1"connections or 31/2"to 36"(89mm to 914mm)in 1/4"(6mm)increments for 3/4"connections. r-r—k— s1 ---- _ Ti i i �i ii _ i i_i _ I_ H - liii \'‹ i i, , i i i��� � I ii ji �� i \-,-====lftli-_____i L r -; r--z F) ' L_ -J System Fitting Inlet Fitting 2-1/4" [57 mm] Dia. 3 - J Hole in Ceiling 1-15/16" [49mm] Dia. °A" Dimension Nominal Escutcheon Position • Ceiling L »> 1/8° A Ceiling ' [3 mm] 1/4" [6 mm] Escutcheon Adjustment 1/4" [6mm] \IS. ' " " -\\\ Escutcheon Adjustment Escutcheon 1/2" [12 mm] Adjustment 2-27/32" 157FG05B [72 mm] Dia. Fig. 5 8. I Model F3QR56 Dry Horizontal Sidewall Sprinkler with Standard Escutcheon (SIN R5734) "A"Dim. 2"to 48"(51mm to 1219mm)in 1/4"(6mm)increments for 1"connections or 2"to 36"(51mm to 914mm)in 1/4"(6mm)increments for 3/4"connections 1-1/2'[38 mm] No— Total Escutcheon i Adjustment Ceiling 1 4"[102 mm] Min. 1-1/4'[32 mm] �. 12'[305 mm] Max. Escutcheon Adjustment 1/4'[6 mm] System Fitting Escutcheon Adjustment Inlet Fitting �["F 2-3/32' ' ,_ . \ + [53 mm] L - i'l ' M 5/8'[16 mm] 3" �� [76 mm] \ rt L 2-1/8" Ws J [54 mm] Dia. Hole in Wall 1/4'[6 mm] Protrusion Sprinkler Can ► at Nominal Escutcheon Position IIIN Nominal Escutcheon Position --o 'A'Dimension 157FG06B Fig.6 Note:The sprinkler can protrudes 1"when escutcheon is in nominal position. Escutcheon adjustment provides-'/a"(-6mm)to+11/4" (+32mm)"A" dimension adjustment range. 9. 1 Model F3QR56 Dry Horizontal Sidewall Sprinkler with Model HB Escutcheon (SIN R5734) . "A"Dim. 31/2"to 48"(89mm to 1219mm)in 1/4"(6mm)increments for 1"connections or 31/2"to 36"(89mm to 914mm)in 1/4"(6mm)increments for 3/4"connections 1'[25.4mm] -.. Total Adjustment Ceiling r 1/2'(12.7mm] –is_ T Escutcheon Adjustment 4'[101.60mm]Min. --' 12'[304.80mm]Max. 1/2'[12.7mm] Escutcheon Adjustment 2 3/32' System Tee ..IIF [53.18mm] .► Inlet Fitting -F--\ r I 111) v 4 2-13/64' 3 1/2' �,� [55.88mm] [88.9mm] Dia. Escutcheon Dia. — 2 1/2' Dia. [63.5mm] Hole in Wall 1-1/4'[31.75mm]Nominal Protrusion Sprinkler Can 'A'Dimension — Escutcheon Nominal Position 157FG07B of Escutcheon Ag. 7 Note: The sprinkler can protrudes 11/4"when escutcheon is in nominal position. Escutcheon adjustment provides 1/2"(-12.7mm)to+1/2"(+12.7mm) "A"dimension adjustment range. 10. • I Model F3QR56 Dry Horizontal Sidewall Sprinkler with Model FP Recessed Escutcheon(SIN R5734) "A"Dim. 31/2"to 48"(89mm to 1219mm)in 1/4"(6mm)increments for 1"connections or 3W to 36"(89mm to 914mm)in 1/4"(6mm)increments for 3/4"connections Ceiling r Li i 1-13/32' Escutcheon [36 mm] 4'[102 mm]Min. S stem FittingCup co cULus, NYC:6'[152 mm]Max. Y Inlet Fitting FM: 12"[305 mm]Max. ' _sem �� iii+�. \ — I 5/8'[16 mm] it i� �\ , It /1 \ \\\ , 3-7/32' [82 mm]Dia. 2-1/2' [64 mm]Dia. _ Hole in Wall Nominal Escutcheon Position "Z 2-19/64' [58 mm]Dia. — _,, 1/4'[6 mm] Escutcheon Adjustment 1/2'[12 mm] --...-- 157FG08B --. 'A'Dimension ► Total Escutcheon Adjustment -• 1/4'[6 mm] Escutcheon Adjustment Fig.8 Note:Do not install the Model F3QR56 Dry Horizontal Sidewall sprinkler with the Model FP escutcheon in walls which are positively pressurized with respect to the protected space. 11. Model F3QR56 Dry Horizontal Sidewall Sprinkler with Model Fl Recessed Escutcheon (SIN R5734) "A"Dim. 31/2"to 48"(89mm to 1219mm)in 1/4"(6mm)increments for 1"connections or 31/2"to 36"(89mm to 914mm)in 1/4"(6mm)increments for 3/4"connections P Ceiling ' 1,-..--_] 1/8' Escutcheon - 1 [3 mm] F-1 1 4'[102 mm]Min. System Fitting , m ; cULus, NYC:6'[152 mm]Max. I FM: 12'[305 mm] Max. Inlet Fitting �' -- �_ � � �`\�r II IIIIIIIIIIII1VIII I ,ji 5/8'[16 mm] 111 rrr ; ill..11llllllllll ,ill t �� \��� I 2-27 32' 2-1/4"[57 mm] Dia. Hole in Wall Nominal Position 1-15/16'[49 mm] Dia. L„,1 of Escutcheon • ►- —. 1/4'[6 mm] Escutcheon Adjustment IM-- -r 1/2'[12 mm] 157FG09B -0 •A'Dimension ► Total Escutcheon Adjustment 1/4'[6 mm] Escutcheon Adjustment Fig.9 12. RECOMMENDED EXPOSED MINIMUM BARREL LENGTH WHEN CONNECTED TO WET PIPE SPRINKLER_ SYSTEM (DRY PENDENT SPRINKLER WITH STANDARD ESCUTCHEON SHOWN) WET PPE EXPOSED BARREL AMBENT AMBIENT TEMPERATURE ____ r-'- _ s-I TEMPERATURE ----0 -,- r---FIF)---- 40°F/4°C I 50"F/10°C I 80°F/16°C i - -- _--_1 u u DISCHARGEEXPEND EXPOSED MINIMUM BARREL LENGTH" i - VIIII-I-J—- I ,,fill -' - OF SPRINKLER' (FACE OF FITTING TO TOP OFCELNG)°i �ti====l}I)-__.i NM L_-,ANt=—_) N.(MM) IN.(MM) N.(MM) L I r -,_J IF HUMIDITY AND TEMPERATURE DIFFERENTIAL 40°F(4°C) 0 0 0 r -- - CAUSES CONDENSATION ON THE EXPOSED DRY • NSIDEWRAPPING THE 30°F(-1°C) 0 0 0 MilliBARRELLERWITH INSULATR FOAM INSULATING GSED TAPE OR EQUIVALENT. 20°F(-7°C) 4(100) 0 0 10°F(•12°C) 8(200) 1(25) 0 0°F(48°C) 12(300) 3(75) 0 MINIMUM (HEATED AREA) EXPOSED SEAL THE CLEARANCE SPACE -10°F(•23°C) 14(350) 4(100) 1(25) AROUND THE SPRINKLER TO AVOD BARREL LEAKAGEOCCONDENSATE AROUND THE FRAME,WHICHF AN INTO THE PROTECTED -20°F(-29°C) 14(350) 6(150) 3 Q5) LENGTH AREA AND CONSEQUENT FORMATION OF •30°F(•34°C) 16(400) 8(200) 4(100) COULD NH BR OPERATION OR CAUSE PREMATURE OPERATION.SEE BELOW FOR -40°F(-40°C) 18(450) 8(200) 4(100) RECOMMENDED METHODS. "A" CLEARANCE •50°F(-46°C) 20(500) 10(250) 6(150) DMENSDN HOLE MI -60°F(-51°C) 20(500) 10(250) 6(150) "FOR AMBENT TEMPERATURES EXPOSED TO THE DISCHARGE END OF THE SPRINKLER THAT OCCUR BETWEEN THE VALUES LISTED,USE / THE NEXT COOLER TEMPERATURE. '°THE MINIMUM EXPOSED BARREL LENGTHS NOT THE SAME AS THE "An ���/� "A"DIMENSION.THE MINIMUM EXPOSED BARREL LENGTHS BASED ON A PROPERLY SEALED PENETRATION WITH A MAXIMUM WIND VELOCITY PN THE EXPOSED SPRINKLER OF 30 MPH(48 KM/H).LONGER EXPOSED -- BARREL LENGTHS WLL HELP AVOID FREEXING OF THE WET PPNG � ESCUTCHEON WHERE HIGHER WIND VELOCITY IS EXPECTED. CELNG ,rIu'u '"THE MINIMUM EXPOSED BARREL LENGTH IS MEASURED FROM THE �I� I� FACE OF THE FITTING TO THE INSIDE FACE OF THE WALL FOR DRY tn� DISCHARGE END OF SPRINKLER HORIZONTAL SDEWALL SPRINKLERS. (PROTECTED AREA) _- -..—3"DIA. RECOMMENDED EXPOSED MINIMUM BARREL LENGTHS ALSO APPLY TO DRY HORIZONTAL SIDEWALL SPRINKLERS RECOMMENDED DRY SPRINKLER SEAL ARRANGEMENTS WET PPE (DRY SPRINKLER WITH STANDARD ESCUTCHEON SHOWN) WET PPE ===1,i"▪- 119.====u n t= -i - 1iFF= u n -4-- ILIAL -—�-----bili - „- IIIA-�---{-- -bili -4- 411 hp f'I 1 ��1�'' I 1W_-__II''II --J arm L-- IIIfII �'---- ▪ I _ r 1 I — r ti r S I) 5 MNMUM �„ (HEATED AREA) (HEATED AREA) �„ MNMUM EXPOSED I EXPOSED BARREL % i BARREL LENGTH DECKTITE FLASHING j INSIDE FACE SEAL LENGTH (SEE ABOVE RASCO#4003910 (SEE ABOVE) (RECOMMENDED) Z NNN, //////////. %////// %////////.0 C%////// CLEARANCE HOLE INSULATED FREEZER, OR COOLER STRUCTURE OR EXTERIOR FRAMNG 'I//44//// ///////A. 'I///�///I: :///M.,IA. Va , vn (PROTECTED AREA) IIII��Ij DISCHARGE END OF (PROTECTED AREA) qk 1111 DISCHARGE END OF DRY 1A/ N COLDAREA SPRINKLER ,Y/ IN COLD AREA SPRINKLERDRY -- -- 157FG10C Fig. 10 13. *CAUTION* RELIABLE DRY PENDENT AND DRY HORIZONTAL SIDEWALL SPRINKLERS MAY BE INSTALLED IN A LISTED CPVC SPRINKLER FITTING, ONLY UPON VERIFICATION THAT THE FITTING DOES NOT INTERFERE WITH THE SPRINKLER'S INLET. Do not install dry sprinklers with standard inlets into CPVC fittings that have an internal obstruction;this will damage the sprinkler, the fitting, or both. Short inlet('PL')versions of Reliable dry sprinklers are available that may or may not be compatible with fittings having internal obstructions in existing installations. Sprinklers with the short inlet('PL')should only be installed in CPVC fittings of wet-pipe systems. In all cases,verify sprinkler and fitting dimensions prior to installation to avoid interference. Internal Obstruction No Internal Obstruction Female Female 1111 � f' .l Pipe / `/ Pipe / `/ O Thread Thread O 4 td CPVC Fitting with Internal Obstruction CPVC fitting - No Internal Obstruction Shorter Longer Inlet Inlet Male Male Pipe Pipe -� Thread Thread Dry Sprinkler Dry Sprinkler Short Inlet ("PL") Standard Inlet BE SURE TO ORDER THE CORRECT SPRINKLERS FOR YOUR APPLICATION 016FGO8C Fig. 11 14. « Fig. 42-Model F3 or Model F R Wrench » » « < .» « „ � . . :.:.� . .. . . . . . . . .��: y . . A . . � y �. . , /\ , .4 Fig. ]]-Model XL02Wrench 15. MATERIAL SPECIFICATIONS 0 ITEM# DESCRIPTION MATERIAL SPECIFICATION vA0 1 FRAME BRASS PER UNS C83600 .�w Li" 2 DEFLECTOR BRONZE PER UNS C51000 • j1104 ihr 3 LOAD SCREW BRASS PER UNS C22000 4 SEAT ADAPTOR BRASS ALLOY PER UNS C36000 0 ; 5 BULB INSERT COPPER ALLOY PER UNS C31400 i 6 GLASS BULB GLASS W/GLYCERIN SOLUTION 7 ORIFICE ADAPTOR BRASS ALLOY PER UNS C36000 14$ 0 I 8 OUTER TUBE GALVANIZED STEEL �� I `� 9 INNER TUBE BRASS ALLOY PER UNS C23000 1 10 YOKE BRASS ALLOY PER UNS C38000 I r11 INLET BRASS ALLOY PER UNS C35330 I 12 CAP BRASS ALLOY PER UNS C54400 13 SPRING WASHER/SEAL PTFE COATED BERYLLIUM NICKEL ® 14 FLIP DISK BRASS ALLOY PER UNS C54400 15 CAN/ESCUTCHEON PAINTED OR PLATED MILD STEEL 0 0(PIPE WRENCH MAY ONLY BE USED ON OUTER STEEL PIPE OF SPRINKLER) _ 71 0 I. :lir li r il----- 016fg 10 i� 153fg16 ! Iiji 157fg16 t ! I 0 t 9 D it APPEARANCE OF DEFLECTOR MAY VARY DEPENDING ON MODEL 1 Fig. 16 16. Installation Instructions Model F3QR56 Dry sprinklers must only be installed in the sprinkler assembly other than the wrench boss. When following fittings: inserting or removing the wrench from the sprinkler, 1. The side outlet of an ANSI B 16.3 class 150(malleable care should be taken to prevent damage to the sprin- or ductile) or ANSI B16.4 class 125 (cast) iron pipe kler.The sprinkler is then tightened into the pipe fitting tee to achieve a leak free connection. The recommended 2. The run outlet of an ANSI B 16.3 class 150(malleable minimum to maximum installation torque is 22-30 Ib- or ductile) or ANSI B16.4 class 125 (cast) iron pipe ft (30 —40 N-m) for 1" NPT and ISO7-1R1 sprinklers, tee, with the side outlet plugged (wet-pipe systems and 14-20 lb-ft(19—27 N-m)for 3/4" NPT and IS07- - only) 1R3/4 sprinklers. 3. Spears Manufacturing Company Brass Thread In- 3a.Alternatively, where access to the outer tube of sert Style or Special Reinforced Plastic Thread Style the sprinkler is available, the Model F3QR56 Dry Listed adapter or tee (wet-pipe systems only) (gasket sprinkler may be installed using a pipe wrench. sealed outlets shall not be used) The pipe wrench shall only be permitted to inter- 4. Any Listed CPVC sprinkler adapter or tee only in ac- face with the galvanized steel outer tube portion of cordance with Fig. 11 and upon verification that the the sprinkler (Item #8 in Fig. 16). Do NOT wrench CPVC adapter or tee does not interfere with the sprin- any other portion of the sprinkler assembly. A pipe kler's inlet (wet-pipe systems only) (gasket sealed wrench can install the sprinkler into the fitting with outlets shall not be used) a large amount of torque; consideration should be Model F3QR56 Dry sprinklers must not be installed into el- given to the need for future removal of the sprin- bows,welded outlets,or gasket sealed outlets. Installation of kler because the installation torque will have to be the Model F3QR56 Dry sprinkler is not recommend in cop- matched or exceeded to remove the sprinkler.The per pipe systems, as this may reduce the life expectancy of recommended minimum to maximum installation the sprinkler. torque is 22 - 30 lb-ft (30 — 40 N-m) for 1" NPT In all dry-pipe system installations,the Model F3QR56 Dry and IS07-1 R1 sprinklers, and 14-20 lb-ft(19—27 sprinkler must be installed with protrusion into the fitting in N-m)for 3/4" NPT and ISO7-1 R3/4 sprinklers. accordance with Fig. 1 through Fig.9 in this Bulletin. Do not 4. Standard and Model HB escutcheons can be in- install Model F3QR56 Dry sprinklers with the standard(long) stalled by slipping the escutcheon over the can until inlet fitting into CPVC fittings that have an internal obstruc- the escutcheon is seated against the ceiling or wall. tion (see Fig. 11); this will damage the sprinkler, the fitting, Model Fl escutcheons are installed by pressing the or both. Model F3QR56 Dry sprinklers are available with a escutcheon onto the collar until the escutcheon is short"PL" inlet fitting for installation on CPVC fittings of wet- seated against the ceiling or wall. The Model FP es- pipe sprinkler systems only. cutcheon is installed by pressing or threading the es- Model F3QR56 Dry sprinklers connected to wet-pipe sys- cutcheon into the cup by hand; the escutcheon can tems must be installed with the Exposed Minimum Barrel be tightened against the ceiling or wall by turning the Length required by Fig. 10 located in a Heated Area. escutcheon in a clockwise direction and removed by An orange protective clip is factory installed on the sprin- turning the escutcheon in a counter-clockwise direc- kler to protect the glass bulb thermal element from dam- tion.To install the Model CCP cover plate,first remove age. The clip should remain in place during installation of the protective clip. Install the Model CCP cover plate the sprinkler and be removed when the sprinkler system is on the sprinkler by pressing or threading the cover placed in service. Sprinklers with 3/4" NPT and ISO7-1R3/4 plate into the cup by hand; the cover plate can be inlets are supplied with a protective cap on the inlet that tightened against the ceiling by turning the cover must be removed before installation. plate in a clockwise direction and removed by turning Use the following steps for installation: the cover plate in a counter-clockwise direction. 1. Cut a hole in the wall or ceiling directly in-line with 5. Remove the orange protective clip when placing the the outlet of the fitting. See the Installation Data table sprinkler system in service. for the recommended hole diameter based on the es- cutcheon or cover plate option selected. 2. Apply pipe joint compound or PTFE tape to the male threads of the sprinkler's inlet fitting. 3. Install the sprinkler in the fitting using the installation wrench specified in the Installation Data table. The Model F3 and F3R wrenches are designed to be in- serted into the groves in the sprinkler's wrench boss as shown in Fig. 12. The Model XLO2 wrench is de- - signed to fit into the cup and engage the wrench boss as shown in Fig. 13. Do NOT wrench any part of the 17. Installation Data Required Centerline of Sprinkler Sprinkler Suggested Hole Diameter in Installation Model Escutcheon or Cover Plate Wall or Ceiling Tube/Inlet to Finished Ceiling Wrench Vertical Dimension* Standard Escutcheon 2-1/8"(54 mm) F3 or F3R HB Extended Escutcheon 2-1/2"(64 mm) F3QR56 Dry Fl Recessed Escutcheon 2-1/4"(57 mm) Not Pendent Applicable FP Recessed Escutcheon XL02 2-1/2"(64 mm) CCP Cover Plate Standard Escutcheon 2-1/8"(54 mm) 4-5/8"to 12-5/8" HB Extended Escutcheon 2-1/2"(64 mm) (118 mm to 321 mm) F3 or F3R F3QR56 Dry Fl Recessed Escutcheon 2-1/4"(57 mm) cULus,NYC Horizontal 4-5/8"to 6-5/8" Sidewall FP Recessed Escutcheon 2-1/2"(64 mm) (118 mm to 168 mm) XLO2 Fl Recessed Escutcheon 2-1/4"(57 mm) FM FP Recessed Escutcheon 2-1/2"(64 mm) 4-5/8"to 12-5/8" (118 mm to 321 mm) *Based on 5/8" (16 mm)centerline of sprinkler tube/inlet to defector vertical distance. Maintenance Ordering Information The Model F3QR56 Dry Sprinklers should be inspected Specify: and the sprinkler system maintained in accordance with 1. Sprinkler: [Model F3QR56 Dry Pendent SIN R5714] NFPA 25. Do not remove the factory applied thermally sen- [Model F3QR56 Dry Horizontal Sidewall SIN R5734] sitive wax fillet between the bulb supporting cup and the 2. Escutcheon/Cover Plate: [None][Standard escutch- wrenching boss. Do not replace this wax with a substitute eon][Model HB extended escutcheon][Model Fl substance. recessed escutcheon][Model FP recessed escutch- An Alternate substance may interfere with proper operation eon][Model CCP cover plate— pendent only] of the sprinkler. Do not clean sprinklers with soap and water, 3. Inlet Threads: [1" NPT][IS07-1 R1][3/4" NPT][1S07- ammonia or any other cleaning fluids. Remove dust by us- 1 R3/4] ing a soft brush or gently vacuuming. Replace any sprin- 4. Inlet Fitting: [Long —Standard Inlet Fitting][Short "PL" kler which has been painted (other than factory applied) or —Wet Pipe Systems only] damaged in any way.A stock of spare sprinklers should be 5. Sprinkler Temperature Rating: See Temperature Rat- maintained to allow quick replacement of damaged or op- ings table erated sprinklers. Prior to installation, sprinklers should be 6. Sprinkler Finish: See Finishes Table maintained in the original cartons and packaging until used 7. Escutcheon/Cover Plate Finish: See Finishes Table to minimize the potential for damage to sprinklers that would 8. Length: "A" Dimension (face of tee to face of ceiling cause improper operation or non-operation. or wall) in 1/4" (6 mm) increments—See Fig. 1 through Fig. 9 Note: The "A" dimension is based on a nominally gauged pipe thread "make-up" of .600" (15mm) per ANSI B2.1 [approxi- mately 7'/z threads]. The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years,. Manufactured b Reliable Automatic Sprinkler Co., Inc. f Recycled Rel ® (800)431-1588 Sales Offices �� Paper lab (800)848-6051 Sales Fax Revision lines indicate updated or new data. (914)829-2042 Corporate Offices www.reliablesprinkler.com Internet Address EG.Printed in U.S.A.10/16 P/N 9999970175 • Bulletin 044 November 2018 Model KFR-CCSReliabi °J ® K5.6 (80 metric) (17 Combustible Concealed 0 Space Upright Sprinkler o (SIN RA4454) (17 0- Features 1. cULus Listed for areas of coverage up to o° 256 square feet. . 2. 1,000 ft2 (92.9 m2) hydraulic design area for wet-pipe and most dry-pipe systems. 3. Sprinkler may be installed on the same branch line that supplies sprinklers below ceiling. 4. Nominal K-factor of 5.6 (80 metric). h.. 5. Fusible link operating element. 6. Quick Response Sprinkler. 7. 212°F (100°C) Temperature Rating Product Description Reliable's Model KFR-CCS Combustible Concealed Space Model KFR-CCS Sprinkler is a quick response, upright, specific application The performance of the Model KFR-CCS Sprinkler in corn- sprinkler designed to provide protection of specific light haz bustible concealed spaces was clearly evident during the and combustible and noncombustible concealed spaces re- _ full scale fire testing of this product, quiring sprinkler protection. The KFR-CCS sprinkler is spe Concealed spaces between floors, as well as low pitch at- cifically listed for the protection of combustible concealed tics (slope of 2:12 or less) are inherently shallow. Standard spaces described in NFPA 13(2016)section 8,15.1.6. spray sprinklers,by design,have an umbrella-like spray pat- The Model KFR-CCS Sprinkler utilizes a fast response tern that poses a difficult challenge when trying to achieve solder link fusible element. It has demonstrated response effective coverage within a shallow space. The Model KFR- times in laboratory tests which are five to ten times faster CCS Sprinkler addresses the difficult "above ceiling" fire than standard response sprinklers.This feature enables the challenge for both wet pipe and dry pipe sprinkler systems. sprinkler to apply water to a fire much faster than standard sprinklers of the same temperature rating. WARNING Application Model KFR-CCS Combustible Concealed Sprinklers de- The Model KFR-CCS Sprinkler is designed for installation scribed herein must be installed and maintained in compli ance with this document,as well as with the applicable stan- into: dards of the National Fire Protection Association (NFPA), in A. CPVC Pipe**—Wet Sprinkler Systems addition to the standards of any other authorities having ju- B. Steel Pipe—Wet or Dry Sprinkler Systems risdiction. Failure to do so may impair the performance of **The Model KFR-CCS Sprinkler is UL Listed for use with these devices.The property owner is responsible for main- UL Listed CPVC Pipe and UL Listed CPVC Fittings. taining their fire protection system and devices in proper op- The allowable system construction types include: erating condition. The installing contractor or manufacturer should be contacted with any questions. • Wood truss and wood bar joist Design Specifications • Noncombustible insulation filled solid or composite A. CPVC Pipe Sprinkler Systems(Refer to Figs.2&3) wood joist The Model KFR-CCS Sprinkler is designed to be in- • Exposed solid wood joist; maximum 12 in. (305mm) stalled into CPVC pipe sprinkler systems. It is listed depth (steel pipe only) to provide fire sprinkler protection of combustible con- cealed areas where the construction methods consist of: • Obstructed wood truss; top chord greater than 4 in. 1. Wood trusses or wood bar joist(Refer to Fig. 2) (102 mm) depth (steel pipe only) 2. Noncombustible insulation-filled solid wood or composite wood joists** (Refer to Fig. 3) Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 • Technical Data Discharge Max.WorkingMin.WorkingTemperature Sprinkler Coefficient Thread p Fusible " Identification (K factor) Response Pressure Pressure Rating Element Finish Approvals Number(SIN) size Color English Metric English Metric English Metric English Metric RA4454 5.6 80 Quick Y2 NPT 175psi 12bar 7psi 0.48 bar 212°F 100°C Green Bronze cULus Response Listed` *cULus Listing applies only for the installations and conditions indicated in the"Design Specifications"Section of this bulletin. Material Data (Refer to Fig. 1): Frame Deflector Load Cup Sealing Washer Strut Lever Fusible Ejection Spring Screw Element - Nickel Alloy coated Stainless Brass Brass Brass Bronze with PTFE Adhesive Stainless Steel Stainless Steel Nickel Alloy Steel Tape _ When using 1 in. (DN25) or larger pipe, a hanger must be Sprinkler Components located at the truss nearest a sprig for purposes of restraint. If using 3/4 in.(DN19)piping,all sprigs over 12 in. (305 mm) must be laterally braced using methods described in the 1.65141.9' NFPA standards. Where the CPVC must be offset up and over an obstruction and the pipe exceeds the allowed hori- f// ' r ••� DEFLECTOR zontal positioning requirements specified above as well as EVER •Ill; shown in Figs. 2 and 3, additional Model KFR-CCS Sprin- LOAD SCREW klers are to be installed to protect the CPVC products.A min- n.,tim� LMI( 11; imum lateral distance of 18 in.(457 mm)must be maintained �j ,� - STRUT between the CPVC pipe and heat pumps, fan motors, and SEALING ,/ CAP heat lamps. WASHER )�I-�, EJECTION SPRING Concealed Space Area: 2,25[57.1] '.1. "� The area of the concealed space is not limited; however, ;jJ% FRAME for both Figs.2 and Fig.3 where CPVC pipe is being utilized, draft-curtains or full height walls must be provided at 1,000 ft2 (93 m2) areas. This draft curtain shall be at least 1/3 the depth of the concealed space or 8 in. (203 mm),whichever I 41111$ is greater, and be constructed using a material that will not allow heat to escape through or above the draft curtain. Concealed Space Size: Fig. 1 The Model KFR-CCS sprinkler is specifically listed for use **Note: In order to be considered "noncombustible insu- in horizontal combustible concealed spaces with a slope not lation-filled, solidwood or composite wood joists" exceeding 2 in 12 with combustible wood truss, wood joist construction, the insulation (including insulation construction, or bar joist construction having a combustible provided with a combustible vapor barrier), must upper surface and where the depth of the space is less than completely fill the pockets between the joists to 36 in (914 mm) from deck to deck, from deck to ceiling, or the bottom of the joists. Insulation installed above with double wood joist construction with a maximum of 36 in. the elevation of Model KFR-CCS sprinklers in (914mm)between the top of the bottom joist and the bottom wood truss, solid wood joist or composite wood of the upper joist. NFPA 13 permits the use of the Model joist must be secured into place with metal wire KFR-CCS sprinkler (a) where the space is less than 12 in netting. The metal wire netting is intended to hold (305 mm) from deck to deck or deck to ceiling, and/or (b) the insulation in place should the insulation be- where a portion of the protected space exceeds 36 in. (900 come wet by the operation of Model KFR-CCS mm). Sprinklers in the event of a fire. System Type: In order to use the CPVC pipe and fittings, the horizontal Light hazard,wet pipe system, runs of pipe must be a maximum of 6 in.(152 mm)above the ceiling or noncombustible ceiling insulation,or 1/3 the depth Minimum Installation Distance(Spacing) Between of concealed space (as measured from the top surface of Sprinklers: the ceiling to the bottom of the deck above), whichever is 6 ft. (1.83 m) smaller(Refer to Figs. 2&3). (Note:This minimum spacing does not apply to any ad- The CPVC piping can then be used to supply the Model ditional sprinklers that are required for protection of KFR-CCS Sprinklers, as well as the sprinklers installed be CPVC piping that is offset over an obstruction) low the ceiling.Unless modified by this technical data sheet, all other guidelines provided by the CPVC pipe and fittings manufactures must be followed. 2. Maximum Distance(Spacing) Between Sprinklers: composite wood joists** (Refer to Fig. 6) 14 ft. (4.27 m)for concealed spaces that are less than 18" 4. Obstructed wood trusses; top chord more than 4" (457 mm)in depth. deep (Refer to Fig. 7). 16 ft.(4.88 m)for concealed spaces that are 18"(457 mm) **Note: In order to be considered "noncombustible insu- or more in depth lation-filled, solid wood or composite wood joists" Maximum Coverage Area Per Sprinkler: construction, the insulation (including insulation 196 ft2(18.2 m2)for concealed spaces are less than 18 in provided with a combustible vapor barrier), must (457 mm) in depth. completely fill the pockets between the joists to the 256 ft2 (23.8 m2) for concealed spaces constructed that bottom of the joists. Insulation installed above the are 18"(457 mm)or more in depth. elevation of Model KFR-CCS sprinklers in wood truss, solidwood joist or composite wood joist Note:Sprinkler spacing is determined by the depth of the must be secured into place with metal wire netting. concealed space at the location of the installation. The metal wire netting is intended to hold the insula When transitions occur in the concealed space,the sprin tion in place should the insulation become wet by klers may immediately be spaced at the largest approved the operation of Model KFR-CCS Sprinklers in the coverage area per the listing for the concealed space depth event of a fire. (Refer to Fig. 8) Concealed Space Area: Deflector Position: The area of the concealed space is not limited; however, At or below the bottom of the top chord; 1.5 in. (38 mm) for wood truss construction or concealed spaces of non- minimum to 4 in. (102mm) maximum below upper deck (or combustible bar joist construction (Refer to Fig. 4)draft-cur- insulation if present)for wood truss construction or wood bar tains or full height walls must be provided at 1,000 ft2(93 m2) joist construction(Fig. 2). areas.This draft curtain shall be at least 1/3 the depth of the 1.5 in. (38 mm)minimum to 4 in. (102mm)maximum below concealed space or 8 in. (203 mm), whichever is greater, bottom of insulation for noncombustible insulation-filled solid and be constructed using a material that will not allow heat or composite joist construction (Fig.3). to escape through or above the draft curtain. For solid wood joist construction (Refer to Fig. 5) and ob- Minimum Distance Away From Face of Wood Truss structed wood truss construction (Refer to Fig. 7), blocking or Top Chord of Bar Joist must berovide in each upper pper deck and ceiling joist chan- 4.5 in. (114 mm)(Refer to Fig. 2) nel at a maximum 32 ft.(9.75 m)intervals.This blocking shall Remote Area: be installed to the full depth of the joist and be installed so as 1,000 ft2(92.90 m2) to not allow heat to escape through or above the blocking. (Note: Additional sprinklers that are required for protec- The blocking must be constructed using a noncombustible tion of CPVC piping that is offset over an obstruc- material. Draft curtains must be protrude below the joist a tion do not need to be included in the remote area.) minimum of 6 in. (152 mm) or 1/3 the space, whichever is Required Density: greatest and run parallel with the joist spaced at 31 ft. (9.45 0.10 gpm/ft2(4.08 Lpm/m2) m) width maximum to limit the area to a maximum of 1,000 ft2(93 m2).The draft curtain may be constructed of in. (6.4 Minimum Operating Pressure: m)plywood to prevent heat from escaping beyond the area. 7 psi (0.48 bar) For noncombustible insulation-filled, solid wood joist or Obstruction Rules: composite wood joist construction (Refer to Fig. 6), the re- quirement for draft curtains or blocking does not apply. All obstruction criteria per the applicable version of NFPA 13 apply, unless modified by this Bulletin (Refer to Fig. 7). Concealed Space Size: The KFR-CCS is classified as an Extended Coverage Up- The Model KFR-CCS sprinkler is specifically listed for use right Spray Sprinkler when installed in locations where the in-horizontal combustible concealed spaces with a slope not maximum coverage area per sprinkler exceeds 225 ft2(20.9 exceeding 2 in 12 with combustible wood truss, wood joist m2).The KFR-CCS is classified as a Standard Upright Spray construction, or bar joist construction having a combustible Sprinkler when installed in locations where the maximum upper surface and where the depth of the space is less than coverage area per sprinkler is 225 ft2(20.9 m2)or less. 36 in (914 mm)from deck to deck, from deck to ceiling, or with double wood joist construction with a maximum of 36 B. Steel Pipe Systems (Refer to Figs.4,5, 6, &7) in. (914 m)between the top of the bottom joist and bottom of The Model KFR-CCS Sprinkler is designed to be in- the upper joist. NFPA 13 permits the use of the Model KFR- stalled into steel pipe sprinkler systems. It is listed to CCS sprinkler (a) where the space is less than 12 in (305 provide fire sprinkler protection of combustible con- _ mm)from deck to deck or deck to ceiling, and/or(b)where cealed areas where the construction methods consist of: a portion of the protected space exceeds 36 in. (914 mm). 1. Wood trusses or wood bar joists (Refer to Fig. 4) System Type: 2. Solid wood joist construction where the upper ceil- Light hazard,wet or dry pipe system. ing joists may have a maximum depth of 12 in. (305 mm). (Refer to Fig. 5). Minimum Installation Distance (Spacing) Between 3. Noncombustible insulation-filled, solid wood or Sprinklers: 6 ft. (1.83 m) 3. Maximum Distance(Spacing) Between Sprinklers: Installation Instructions 14 ft. (4.27 m)for concealed spaces that are less than 18" Model KFR-CCS Sprinklers are to be installed in the up- (457 mm) in depth. right position with their frames arms parallel with the pipe's 16 ft. (4.88 m)for concealed spaces that are 18" (0.46 m) run (Refer to Figs. 2 through 6). When installing the Model or more in depth KFR-CCS sprinkler use only the Reliable Model W2 installa- Maximum Coverage Area Per Sprinkler: tion wrench. Usage of any other type of installation wrench 196 ft2(18.2 m2)for concealed spaces are less than 18 in may damage the sprinkler and will immediately void the (457 mm) in depth. manufacture's warranty. 256 ft2 (23.8 m2) for concealed spaces constructed that Note:A leak tight 1/2"NPT(R1/2)sprinkler joint can be ob- are 18" (457 mm)or more in depth. tained with an installation torque of approximately Note:Sprinkler spacing is determined by the depth of the 8-18 ft-lbs (10.8—24.4 N-m). Do not tighten sprin- concealed space at the location of the installation. When klers over these recommended limits. Doing so transitions occur in the concealed space,the sprinklers may may cause premature leakage and or operation. immediately be spaced at the largest approved coverage Maintenance area per the listing for the concealed space depth (Refer to Model KFR-CCS Sprinklers should be inspected and main- Fig. 8) tained in accordance with the applicable version of NFPA Deflector Position: 25.Do not clean sprinklers with soap and water,ammonia or At or below the bottom of the top chord; 1.5 in. (38 mm) any other cleaning fluids. Remove dust by using a soft brush minimum to 4 in. (102mm) maximum below upper deck(or or gentle vacuuming. Replace any sprinkler which has been insulation if present)for wood truss construction or wood bar painted(other than factory applied)or damaged in any way. joist construction(Fig.4). A stock of spare sprinklers should be maintained to allow 1.5 in. (38 mm) minimum to 2 in. (51 mm) maximum be- quick replacement of damaged or operated sprinklers. Prior low the bottom of the upper joist for concealed spaces con- to installation,sprinklers should be maintained in the original structed of exposed solid wood joists(Fig 5). cartons and packaging to minimize the potential for damage 1.5 in.(38 mm)minimum to 4 in. (102mm)maximum below to sprinklers that would cause improper operation or non- bottom of insulation for noncombustible insulation-filled solid operation. or composite joist construction(Fig. 6). 1.5 in. (38 mm)minimum to 2 in. (51 mm)maximum below Guarantee the bottom of the top chord for spaces constructed of ob- structed wood trusses(Fig. 7). For Reliable Automatic Sprinkler Co., Inc. guarantee, Minimum Distance Away From Face of Wood Truss terms, and conditions,visit www.reliablesprinkler.com. or Top Chord of Bar Joist 4.5 in. (114 mm)(Refer to Fig.4) Remote Area: The remote area for wood truss construction, noncombus- tible bar joist construction (Refer to Fig. 4) and solid wood joist construction (Refer to Fig. 5) is 1,000 ft2 (92.90 m2) for wet pipe systems and dry pipe systems. The remote area for noncombustible insulation-filled solid wood joist or composite wood joist construction is to be cal- culated per the requirements of the applicable version of NFPA 13(Refer to Fig. 6). Required Density: 0.10 gpm/ft2(4.08 Lpm/m2) Minimum Operating Pressure: 7 psi (0.48 bar) Obstruction Rules: All obstruction criteria per the applicable version of NFPA 13 apply, unless modified by this Bulletin (Refer to Fig. 7). The KFR-CCS is classified as an Extended Coverage Up- right Spray Sprinkler when installed in locations where the maximum coverage area per sprinkler exceeds 225 ft2(20.9 m2).The KFR-CCS is classified as a Standard Upright Spray Sprinkler when installed in locations where the maximum coverage area per sprinkler is 225 ft2(20.9 m2)or less. 4. CPVC PIPE CONSTRUCTION: WOOD TRUSS OR WOOD BAR JOIST TOP CHORD DEPTH 4 4-1/2" [114mm] MINIMUM FROM (100 mm) OR LESS —..." CENTERLINE OF SPRINKLER TO FACE OF WOOD TRUSS ORUPPER 1 TOP CHORD OF BAR JOIST /— DECK \ \ \ SEE NOTE 1 �.--.` \ \ N , MAXIMUM 6" [152mm] S i r / / — SEE NOTE 2 --1( I KFR—CCS SPRINKLERS TO BE I I INSTALLED WITH FRAME ARMS I t IN—LINE (PARALLEL) WITH PIPE. I L— --1 .0 8MUCTION. 5 '............. Ci 1 CEILING 5-7I N ill N. w N \ \ .ia U, —PIPESHALL BELOCATED 6" ABOVE THE TOP OF THE OR A C CEIUNG, WHEN OFFSETTING CPVC PIPE OVER MAXIMUM OF ONE—THIRD (1/3) THE DEPTH OF THE CONCEALED OBSTRUCTION, A KFR—CCS SPRINKLER MUST BE SPACE ABOVE THE TOP OF THE CEILING, WHICHEVER IS SMALLER. INSTALLED DIRECTLY ON THE PIPE OVER THE OBSTRUCTION. Note 1: Deflector at or below bottom of top chord; 1-1/2" (38 mm) minimum to 4" (102 mm) maximum below bottom of roof deck or insulation. Note 2: Distance evaluated as part of cULus Listing: 12" to 36" (305 to 914 mm). NFPA 13 permits the installation of these sprinklers in combustible concealed spaces where (a) the distance from deck to deck or deck to ceiling is less than 12" (305 mm) and/or (b) a portion of the protected area exceeds a depth of 36" (914 mm). Fig. 2 r CPVC PIPE CONSTRUCTION: NONCOMBUSTIBLE INSULATION FILLED SOLID WOOD OR COMPOSITE WOOD JOIST UPPER NONCOMBUSTIBLE SOLID WOOD COMPOSITE WOOD DECK INSULATION / JOISTS JOISTS \ &\ & 4.0 \ , L:\ 1 \ /\/ \ \ rill rA' ilii' ( MAXIMUM SEE NOTE 3 SEE NOTE 2 \r i --.► �— 6" [152mm] SEE NOTE 2 r KFR—CCS SPRINKLERS TO BE D. INSTALLED WITH FRAME ARMS LIN—LINE (PARALLEL) WITH PIPE.J i 11o I . �J ,'€: i::?; \� \ CEILING \ \ ; \ N \ PIPE SHALL BE LOCATED 6" ABOVE THE WHEN OFFSETTING CPVC PIPE OVER TOP OF THE CEIUNG, OR A MAXIMUM OF OBSTRUCTION, A KFR—CCS ONE—THIRD (1/3) THE DEPTH OF THE SPRINKLER MUST BE INSTALLED CONCEALED SPACE ABOVE THE TOP OF DIRECTLY ON THE PIPE OVER THE THE CEIUNG, WHICHEVER IS SMALLER. OBSTRUCTION. Note 1: Deflector distance below bottom of joist/insulation to be 1-1/2" to 4" (38 mm to 102 mm). Note 2: Distance evaluated as part of cULus Listing: 6" to 36" (152 to 914 mm). NFPA 13 permits the installation of these sprinklers in combustible concealed spaces where a portion of the protected area exceeds a depth of 36" (914 mm). Note 3: Maximum distance evaluated as part of cULus Listing: 60" (1524 mm). Fig. 3 STEEL PIPE CONSTRUCTION: WOOD TRUSS OR WOOD BAR JOIST (TOP CHORD 4" OR LESS IN DEPTH) FROM FACE OF WOOD TRUSS OR TOP WOOD TRUSS OF CHORD OF BAR JOIST OR BAR JOIST 4.5" [114mm] MINIMUM DISTANCEUPPER DECK 7 „ , i, , , , , , , ,, , , • (i77 /77 77ii / 77 Z // / <<" / ZZA SEE NOTE 1 — f i KFR—CCS SPRINKLERS TO BE INSTALLED WITH FRAME ARMS SEE NOTE 2 LIN—UNE (PARALLEL) WITH PIPE.J LOCATION OF STEEL PIPE IN CONCEALED SPACE IS NOT RESTRICTED CEILING —� N Note 1: Deflector at or below the bottom of the top chord; 1-1/2” (38 mm) to 4" (102 mm) below bottom of roof deck or insulation. Note 2: Distance evaluated as part of cULus Listing: 12" to 36" (305 to 914 mm). NFPA 13 permits the installation of these sprinklers in combustible concealed spaces where (a) the distance from deck to deck or deck to ceiling is less than 12" (305 mm) and/or (b) a portion of the protected area exceeds a depth of 36" (914 mm). Fig. 4 . STEEL PIPE CONSTRUCTION: EXPOSED SOLID WOOD JOIST; MAX 12" DEPTH 2X SOLID WOOD JOISTS UPPER DECK N N N N N \ N N N NN N N \ N N SEE NOTE 3 1"1 L SEE NOTE 2 IL ! \ter -1 LOCATION OF STEEL SEE NOTE 1 KFR—CCS SPRINKLERS TO BE PIPE IN CONCEALED INSTALLED WITH FRAME ARMS SPACE IS NOT I IN—LINE (PARALLEL) WITH PIPE. I L J RESTRICTED "ll o i N N N N, N, .N N .. N N N „. , CEILING Note 1: Deflector distance below bottom of joist to be 1-1/2" to 2" (38 mm to 51 mm). Note 2: Distance evaluated as part of cULus Listing: 6" to 36" (152 to 914 mm). NFPA 13 also permits the installation of these sprinklers in combustible concealed spaces where a portion of the protected area exceeds a depth of 36" (914 mm). Note 3: Maximum distance evaluated as part of cULus Listing: 60" (1524 mm). Fig. 5 STEEL PIPE CONSTRUCTION: NONCOMBUSTIBLE INSULATION FILLED SOLID WOOD OR COMPOSITE WOOD JOIST NONCOMBUSTIBLE SOLID WOOD COMPOSITE WOOD UPPER INSULATION JOISTS JOISTS DECK , , /\\ , , , , \ K 1 \ / \ riii iiiiii ilii SEE NOTE 3 1 i1.---' ---- ! LSEE NOTE 2 �• SEE NOTE 1 P \1 KFR—CCS SPRINKLERS TO BE, LOCATION OF STEEL iINSTALLED WITH FRAME ARMS I PIPE IN CONCEALED i IN—LINE (PARALLEL) WITH PIPE. I SPACE IS NOT L J RESTRICTED CEIUNG Note 1: Deflector distance below bottom of joist/insulation to be 1-1/2" to 4" (38 mm to 102 mm). Note 2: Distance evaluated as part of cULus Listing: 6" to 36" (152 to 914 mm). NFPA 13 permits the installation of these sprinklers in combustible concealed spaces where a portion of the protected area exceeds a depth of 36" (914 mm). Note 3: Maximum distance evaluated as part of cULus Listing: 60" (1524 mm). Fig. 6 STE=L SIRE CONSTRUCTION: OBSTRUCTED WOOD TRUSS OR BAR JOIST (TOP CHORD MORE THAN 4 IN. DEPTH) WOOD TRUSS OR BAR JOIST UPPER DECK 1!/////////// //////////</////// ////////////// ///////// // //////////i 1 1 SEE NOTE 3 \\ \ —SEE NOTE 1 SEE NOTE 2 \\i KFR—CCS SPRINKLERS TO BE o INSTALLED WITH FRAME ARMS LOCATIONIS OfNOT STEEL PIPE IN CONCEALED I IN—LINE (PARALLEL) WITH PIPE. I RESTRICTEDSPACE a _ 6 \\ //////////,//// /////,a CEILING Note 1: Deflector distance below bottom of joist to be 1-1/2" to 2" (38 mm to 51 mm). Note 2: Distance evaluated as part of cULus Listing: 6" to 36" (152 to 914 mm). NFPA 13 also permits the installation of these sprinklers in combustible concealed spaces where a portion of the protected area exceeds a depth of 36" (914 mm). Note 3: Maximum distance evaluated as part of cULus Listing: 60" (1524 mm). Fig. 7 SPRINKLER SPACING AT CHANGE IN CONCEALED SPACE DEPTH CONSTRUCTION: WOOD TRUSS OR WOOD BAR JOIST (SEE NOTE 1) KFR—CCS SPRINKLER UPPER DECK N. Ns Ns. N Ns j LESS THAN t' 151 A 18" [457mm] (SEE NOTE 1) 1 18' -.....7 [457mm] V//e/i//T/i///i/. // /F////-24-sC/444r i//////// 7////,l I 18" [457 mm] --___ , OR GREATER / A- (SEE NOTE 1) SEE NOTE 2 \p / d 1 / _1 „ / CEILING 7' — 0” MAX 8'-0" MAX MAXIMUM SPACING MAXIMUM SPACING 14' X14' [4.3mX4.3m] --.--1/1---.---. IN—.- 16' X 16' [4.9mX4.9m] 196 SF [18.2 ml 256 SF [23.8 ml Note 1: Measuring points for solid wood joist, composite wood joist, and obstructed wood truss or bar joist construction are the bottom of the upper chord and top of the lower chord. Note 2: For sloping concealed spaces, break point between sprinkler spacings is the point where the depth of the space equals 18" [457 mm]. Fig. 8 DISTANCE FROM CENTERLINE MAXIMUM ALLOWABLE OF SPRINKLER TO SIDE OF DISTANCE OF DEFLECTOR TTOM UPPER DECK OR BOTTOM OF OBSTRUCTION. ABOVE DIMENSION"A" OBSTRUCCTIIONOF NONCOMBUSTIBLE INSULATION DIMENSION"B" <12' 0' OBSTRUCTION [<305mmj [Omm] 'B" 7. KFR-CCS 12"TO<18" 2.5" (305mm TO c457mm] [64mm] SPRINKLER 18'TO<24' 3.5' [457mm TO<610mm] [89mm] —.... A" ....— 24"TO<30" 5.5' [610mm TO<762mm] [140mm] 30"TO<36' 7.5' NOTE: [762mm TO<914mm] [191mm] WEB MEMBERS AND GUSSETS SHALL 36"TO<42' 9.5' NOT BE CONSIDERED OBSTRUCTIONS [914mm TO<1067mm) [241mm] PROVIDED THE MINIMUM 4-1/2" 42"TO<48" 12" LATERAL DISTANCE(FIG.2&FIG.4)REQUIRED [1087mm TO<1219mm] [305mm] BY THE SPECIFIC APPLICATION LISTING 48"TO<54" 14" IS MAINTAINED. [1219mm TO<1372mm] [356mm] 54"TO<60' 16.5" [1372mm TO<1524mm] [419mm] UPPER DECK OBSTRUCTION KFR-CCS OBSTRUCTION SPRINKLER KFR CCS "C" "C" SPRINKLER k•-"D"-•-1 LOWER DECK --.— A"--..-I "D" L...-- " z— ELEVATION VIEW PLAN VIEW Az3C OR 3D(USE DIMENSION C OR D,WHICHEVER IS GREATER) MAXIMUM CLEAR DISTANCE REQUIRED IS 24 IN.(610 mm) MINIMUM HORIZONTAL DISTANCE VERTICAL DISTANCE DIMENSION"A" BELOW DEFLECTOR "A" DIMENSION"B" UPPER DECK my 3" [s152mm] [78mm] "B" i >6"TO 9" 4" [>152mm TO 229mm] [102mm] KFR-CCS >9"T012' 6" SPRINKLER (>229mm TO 305mm) [152mm] OBSTRUCTION >12'70 15" 8' [>305mm TO 381mm] [203mm] LOWER DECK >15'1O18' 9.5" ���,,,,,,,,,....... ��� (>381 mm TO 457mm] [241mm] >18"TO 24" 12.5' [>457mm TO 610mmj [318mm] >24"TO 30' 15.5" [>610mm TO 762mm] [394mm] >30" 18" [>762mm] [457mm] 044FG068 Fig. 9 12. Reliable. . . For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Deluge valves • Flush automatic sprinklers • Detector check valves • Recessed automatic sprinklers • Check valves • Concealed automatic sprinklers • Electrical system • Adjustable automatic sprinklers • Sprinkler emergency cabinets • Dry automatic sprinklers • Sprinkler wrenches • Intermediate level sprinklers • Sprinkler escutcheons and guards • Open sprinklers • Inspectors test connections • Spray nozzles • Sight drains • Alarm valves • Ball drips and drum drips • Retarding chambers • Control valve seals • Dry pipe valves • Air maintenance devices • Accelerators for dry pipe valves • Air compressors • Mechanical sprinkler alarms • Pressure gauges • Electrical sprinkler alarm switches • Identification signs • Water flow detectors • Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory - Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years. _ Manufactured by Reliable Automatic Sprinkler Co.,Inc. 4'♦ Recycled (800)431 15$8 Sales Offices vita Paper iab (800)8481-61051 Sales Fax Revision lines indicate updated or new data. (914)829 2042 Corporate Offices www.reliablesprinkler.com Internet Address EG.Printed in U.S.A.11/18 P/N 9999970449 Reliable FM &UL Groove Butterfly Valve REL-BFG-300-I Material List No. Component Material 1 Upper shaft sealing nut WCB ASTM A216 2 Shaft seal PDM ASTM D2000 as 3 Body DI ASTM A536 4 Upper shaft SS416 ASTM A582 5 Disc DI+EPDM ..,-ill 6 Lower shaft SS416 ASTM A582 4 ---- 7 Lower shaft sealing nut WCB ASTM A216 8 Stem bushing(2.5"to 6") PTFE ASTM D4894 ,�_, Y 8 Stem bushing(8") C95400 ASTM B148 1 9 Gear box Carried Standard Max Working Pressure: 300PSI/21.4 Bar Design Standard: API609 - Groove Standard: ANSI/AWWA C606 YL ® TeFlange Standard: ISO 5211 Tess t Standard: API 598 Temperature: from-20°C to 110°C APPROVED Design and materials are subject to change without notice. Wiring Diagram / SUPERVISORY SWITCH AUXILIARY SWITCH — YELLOW(COMMON) WHITE(COMMON) FIRE ALARM CONTROL BLUE PANEL SUPERVISORY — �— o SWITCH PANEL o SWFR:H —BLACK O RED BLACK `. � WHITE 0--TO AUXILIARY DEVICE OCOMMON RED S.P.S.T.N SWITCH 0 WITH DUAL LEADS BWE S.P.DT.SINGLESWITCH YELLOW SOLDERED TO SOLD SOLDERED TO SWITCH TABS SOLDERED TO COMMON (SWITCH SHOWN IN SWITCH TABS. "FULL OPEN"POSITION) (SWITCH SHOWN IN \ FULL-OPEN"POSITION) / YELLOW TO END OF LINE RESISTER OR GREEN CONNECTION TO GROUND NEXT SUPERVISORY SWITCH GROUND SCREW INSIDE HOUSING - Reliable Automatic Sprinkler Co.,Inc. Bulletin No.:R0043E Manufacturer&Global Distributor of Fire Protection Products www.reliablesprinkler.com Reliable0 FM & UL Groove Butterfly Valve REL-BFG-300-1 0D ry n a \ o II��\�• IMEMIIM- MIC mE MEMO 1E1 1111111- sits IIAB 111111 e I Pc 01114 Dimensions(mm) DN A mu© D E F G H K J P M L Weight 65(2.5") 125 95 32 73 69.1 15.9 7.9 111 153 218 152 90 70 9 10 96.4 8.4kg 76.1 72.3 80(3") 140 100 32 88.9 84.9 15.9 7.9 111 153 218 152 90 70 9 11 97 9.1kg 100(4") 160 100 32 114.3 110.1 15.9 9.5 111 153 218 152 90 70 9 14 115.1 10.1kg 165.1 160.9 165(6) 190 140 32 15.9 9.5 111. 153 218 200 90 70 9 16 132,4 14.7kg 219.1 214.4 200(8") 230 175 32 19 11.1 126 210 232 290 125 102 12 16 147.4 28.7kg 216.3 211.6 Ordering Information Description Size(mm) Part Number Butterfly Valve FM/UL Grooved 300 PSI(Rasco)(73mm) 65(2.5") 7U99002223 Butterfly Valve FM/UL Grooved 300 PSI(Rasco)(76mm) 65(2.5") 7U99002224 Butterfly Valve FM/UL Grooved 300 PSI(Rasco) 80(3") 7U99002225 Butterfly Valve FM/UL Grooved 300 PSI(Rasco) 100(4") 7U99002226 Butterfly Valve FM/UL Grooved 300 PSI(Rasco)(165mm) 165(6") 7U99002228 Butterfly Valve FM/UL Grooved 300 PSI(Rasco)(168mm) 168(6") 7U99002227 Butterfly Valve FM/UL Grooved 300 PSI(Rasco) 200(8") 7U99002229 Reliable Automatic Sprinkler Co.,Inc. Bulletin No.:R0043E Manufacturer&Global Distributor of Fire Protection Products www.reliablesprinkler.com Bulletin 807 May 2019 Reliabi ® Model G Swing Check Valve 1-1/2", 2", 2-1/2", 3",4",6", 8", & 10"Sizes cULus Listed, FM Approved Features • Grooved end connections. • Compact, lightweight design. • Non-slamming, spring loaded clapper to minimize water hammer. • Approved for horizontal and vertical installation. • Streamlined body design provides very low friction loss. • - „ Product Description 6.40 Reliable Model G Swing Check Valves are low friction loss check �'- valves approved for use in fire protection systems.Typical applica- tions include connections between public water supplies and pri- vate fire systems, at the discharge from fire pumps, at gravity tank connections and at fire department pumper connections.All Model G Check Valves are provided with 1/2" NPT (R'/2) supply side and discharge side connections(Item 12,Figure 1). Grooved end con- nections provide fast and easy installation using listed or approved mechanical grooved couplings. Rigid style grooved couplings can be used for positive clamping to resist flexural and torsional loads. Installation The Model G Check Valve shall be installed in accordance with Reliable Model G Swing Check Valve(3") NFPA 13, "Standard for the Installation of Sprinkler Systems," Note: Model G Check Valves may be damaged by excessively turbu- as well as the requirements of any authorities having jurisdic- lent water flow.Model G Check Valves should be installed a reasonable tion. When installed vertically, the direction of flow shall be up distance from pipe transitions,such as pumps,elbows,expanders,re- through the valve (install with flow arrow pointed up). For hor- ducers,or similar devices.Typical piping practices suggest a minimum izontal installations, the hinge pin must be located to the top, distance of five times the pipe diameter for general use. Failure to follow installation instructions may void the warran- ty and listing of the valve. Verify compatibility of the Model G Check Valve materials with the water supply and the environ- ment where the valve will be installed prior to installation. Do not apply lubricants,sealants,or other chemicals to the clapper seal or seat. Technical Data Table A Valve Size Pressure Rating Face-to-Face Eq.Length C=120 Eq.Length C=100 Cv Factor Shipping Dimension Lg Weight 1-1/2"(40 mm) 6-1/4"(159 mm) 6.7'(2.0 m) 4.8'(1.5 m) 36 5 lbs(2.3 kg) 300 psi(20.7 bar) 2"(50 mm) 6-1/2"(165 mm) 9.6'(2.9 m) 6.8'(2.1 m) 67 6 lbs(2.7 kg) 2-1/2"(65 mm) 7.12"(181 mm) 6.0'(1.8m) 4.3'(1.3m) 212 9 lbs(4.1 kg) 76 mm 7.12"(181 mm) 6.0'(1.8m) 4.3'(1.3m) 212 9 lbs.(4.1 kg) 3"(80 mm) 7.62"(194 mm) 5.3'(1.6m) 3.8'(1.2m) 376 11 lbs.(5.0 kg) 4"(100 mm) 250 psi(17.3 bar) 8.44"(214 mm) 7.1'(2.2m) 5.0'(1.5m) 656 17 lbs.(7.7 kg) 6"(150 mm) 10.25"(260 mm) 13.7'(4.2m) 9.8'(3.0m) 1395 38 lbs.(17.2 kg) 165 mm 10.25"(260 mm) 13.7'(4.2m) 9.8'(3.0m) 1395 38 lbs.(17.2 kg) _ 8"(200 mm) 12.5"(318 mm) 15.9'(4.8m) 11.3'(3.4m) 2818 63 lbs.(28.6 kg) 10"(250 mm) 300 psi(20.7 bar) 14.5"(368 mm) 28.8'(8.8m) 20.6'(6.3m) 3928 102 lbs.(46.3 kg) www.reliablesprinkler.com • Model G Swing Check Valve Components Figure 1 Valve Components(refer to Figure 1) Table B L Item Part Name Material (Face to Face Dimension No. See Technical Data Table) 1 Valve Body Gray Cast Iron Class 30 ®8"& 10"VALVES ONLY 2 Seat Bronze C83600 or C93200 3 Clapper Stainless Steel 304 or 17-4 01) 0 4 Facing Seal` EPDM Rubber - • O 0 5 Clamping Ring Stainless Steel 304 �-4' 6 Gasket* EPDM Rubber or PTFE '% // 7 Spring Stainless Steel 302 m'1. 1.1 r'1 8 Hinge Pin Stainless Steel 303 9 Bolt Stainless Steel 18 8 $, lk iii � 10Lockout* Stainless Stee11S-8 I//� 4 1 tit 11 Plug, /e'NPT Steel t� �� _i) \;'� 12 Plug,1/2"NPT Steel � '' ,I 13 Shoulder Eye Steel _�� lh ;:Ir I * Part of Replacement Seal Kit Addit‘ iiMihr IT0 0 - 8o7FG02E 0 0 0 0 0 Replacement Seal Kit Part Numbers Table C Part Number 1-1/2" 2" 21/2" 3" 4" 6" 8" 10" 76 (40 mm) (50 mm) (65 mm) mm (80 mm) (100 mm) (150 mm) 165 mm (200 mm) (250 mm) 6888000015 6888000020 6888040025 6888040025 6888040030 6888040040 6888040060 6888040060 6888040080 6888040090 Maintenance Guarantee The owner is responsible for maintaining the fire protection sys- For Reliable Automatic Sprinkler Co., Inc. guarantee, terms, tern in proper operating condition. Any system maintenance or and conditions,visit www.reliablesprinkler.com. testing that involves placing a system out of service may elim- inate the fire protection that is provided by the fire protection system. Notify any required authorities having jurisdiction and Ordering Information implement appropriate precautions prior to proceeding. Specify: The Reliable Model G Check Valve shall periodically be given 1. Model G Check Valve. a thorough inspection and test. NFPA 25, "Inspection, Testing 2. Size. and Maintenance of Water Based Fire Protection Systems,"pro- vides minimum maintenance requirements. Inspect the interior of the valve and all components for corrosion, damage, and wear at least every five (5) years. Replace any components found to be corroded, damaged, or worn. Increase the fre- - quency of inspections when the valve is exposed to corrosive conditions or chemicals that could impact the valve materials. i,-- 0 0 0 1- 0 0) 0) 0) a> z c Bulletin 807 Reliable Page 2 of 2 May 2019 www.reliablesprinkler.com Bulletin 617 September 2018 NimReilabid Model CR Commercial Riser N. Riser Manifold for -� Commercial ApplicationsCD 3 Available Sizes/Pressure Ratings: N 11/2"(40mm) and 2"(50mm) Threaded - 250 psi (17.2 bar) Working Pressure ,;s + 2"(50mm),21/2"(65mm),&3"(80mm)Grooved-300 £ °`{ . a psi(20.7 bar)Working Pressure 4"(100mm),6"(150mm),&8"(200mm)Grooved- 300 psi(20.7 bar)Working Pressure it Features 1, Cast stainless steel body construction for threaded manifolds. 2. Painted cast ductile iron or welded steel body construc- tion for grooved manifolds. 3. Brass and galvanized Trim. • Basic Trim with Pressure Relief Kit 4. Factory assembled and pressure tested. Commercial riser manifold assembly includes a cU- 5. Available with Test and Drain Valves in various orifice Lus Listed pressure gauge, a '/a" three-way valve, a sizes. drain (ball)valve, and a dedicated waterflow detector 6. Optional Pressure Relief Valve Kit available for all sizes. containing two sets of SPDT (Form C) contacts, hav- 7. Same take-out dimensions for the 11/2"(40mm) and ing an electrical rating of 10A @ 125/250 VAC/2.5 A 2"(50mm)threaded sizes. @ 24 VDC. See Table 3 for triggering flow rates. The 8. Same end-to-end dimensions for the 2"(50mm)through non-adjustable Pressure Relief Kit will maintain system _ 8"(200mm)grooved sizes. pressures below 175 psi (12.1 bar). 9. Approved for installation in horizontal or vertical posi- • Basic Trim with Test and Drain Valves Valve tions. Commercial riser manifold assembly includes a cU- 10. Built in drain port allows hydrostatic testing without Lus Listed pressure gauge, a 1/4" three-way valve, a draining the system. Reliable Model TD Test and Drain Valve, and a dedi- 11. 1/4"three-way valve allows for easy testing and replacing cated waterflow detector containing two sets of SPDT of pressure gauge. (Form C) contacts, having an electrical rating of 10A 12. Dedicated cULus Listed, ULC Listed and FM Approved @ 125/250 VAC/2.5 A @ 24 VDC. See Table 3 for trig- Waterflow Detector assures optimum sensitivity. See gering flow rates. The available test orifice size inside Table 3 for triggering flow rates. the Test and Drain Valve are K2.8 (40), K4.2 (60, or K5.6(80)for 1-1/2"and 2" risers; K4.2(60), K5.6(80), Product Description K8.0(115),or K11.2(160)for 2-1/2"and 3" risers, and The Model CR Commercial Riser comes factory assem- K5.6 (80), K8.0 (115), and K16.8 (240) for 4", 6", and bled with the necessary accessories for a cost effective, yet 8" risers. complete riser assembly. These assemblies are UL Listed, • Basic Trim with Test and Drain Valve&Pressure Relief Kit ULC Listed and FM Approved as a unit. Commercial riser manifold assembly includes a cU- Cast-on lettering or label on the manifold identifies mani- Lus Listed pressure gauge, a '/4" three-way valve, a fold pipe size, flow direction, gauge and drain outlets, and Reliable Model TD Test and Drain Valve, and a dedi- UL Listing and FM Approval markings. cated waterflow detector containing two sets of SPDT The Model CR Commercial Riser is available in four con- (Form C) contacts, having an electrical rating of 10A figurations(see Figures 1 and 2): @ 125/250 VAC/2.5 A @ 24 VDC. See Table 3 for trig- • Basic Trim gering flow rates. The non-adjustable Pressure Relief Commercial riser manifold assembly includes a cU- Kit is available in 175, 185,210,260,and 300 psi mod- Lus Listed pressure gauge, a '/4" three-way valve, a els. The available test orifice size inside the Test and drain (ball)valve, and a dedicated waterflow detector Drain Valve are K2.8 (40), K4.2 (60, or K5.6 (80) for_ containing two sets of SPDT (Form C) contacts, hay- 1-1/2" and 2" risers; K4.2 (60), K5.6 (80), K8.0 (115), ing an electrical rating of 10A @ 125/250 VAC/2.5 A @ or K11.2 (160) for 2-1/2" and 3" risers, and K5.6 (80), 24 VDC. See Table 3 for triggering flow rates. K8.0(115), and K16.8 (240) for 4", 6", and 8" risers. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Installation This drain port shall be sized per the following: • 1. Attach the pressure gauge as shown in Figures 1-4. • 1"(25mm)for 11/2"(40mm) and 2"(50mm) sizes. 2. Install the manifold with the flow arrow pointing • 11/4"(32 mm)for 21/2"(65mm), and 3"(80mm) sizes. towards the SYSTEM side using threaded fittings • 2"(50mm) for 4"(100mm), 6"(150mm) and 8"(200mm) or grooved pipe couplings. sizes. 3. Connect the appropriately sized drain line. Take-out dimensions shall be the same for the 11/2"(40mm) 4. Ensure that the drain valve is in the CLOSED posi- and 2"(50mm)threaded sizes. End-to-end dimensions shall tion. be the same for the 2" (50mm) through 3" (80mm) grooved 5. Place the sprinkler system in service. sizes.Assembly shall have a working pressure rating of[250 - 6. Installation must comply with NFPA 13, Section psi (17.2 bar) (for 11/2" (40mm) and 2" (50mm) threaded 8.16.4.2 manifold assemblies)] [300 psi (20.7 bar) (for 2" through 3" grooved manifold assemblies)]. • Caution: End-to-end dimensions shall be the same for the 4" Automatic sprinkler systems having non-fire protection (100mm) through 8" (200mm) grooved sizes. Assembly connection (permitting continual water flow) require dielec- shall have a working pressure rating of [300 psi (20.7 bar) tric fittings, according to NFPA 13 sect. 4-6,when dissimilar (for 4" (100mm) through 8" (200mm) grooved manifold as- metal piping materials are joined. semblies)]. Note: Use a non-hardening pipe joint compound, or Teflon tape. Table 3 Follow the manufacturer's instructions when using grooved Manifold Sizes Triggering Flow Rate-GPM (LPM) pipe couplings. All 4(15)to 10(38) Listings and Approvals 1. Listed by Underwriters' Laboratories Inc. and ULC Listed. 2. Factory Mutual Approved. 3. NYC MEA 258-93-E Engineering Specification [Model CR Commercial Riser Assembly] shall be [UL Listed][ULC Listed] [Factory Mutual(FM)Approved]for hor- izontal or vertical installation as a one-piece, fabricated as- sembled unit. The[Model CR Commercial Riser Assembly] shall consist of a(choose one): • 11/2" (40 mm) cast, non-welded stainless steel body with threaded end connections • 2" (50 mm) cast, non-welded, stainless steel body with threaded end connections • 2" (50 mm) cast, non-welded, ductile iron body with grooved end connections • 21/2" (65 mm) cast, non-welded, ductile iron body with grooved end connections • 3" (80 mm) cast, non-welded, ductile iron body with grooved end connections • 4" (100 mm) cast, non-welded, ductile iron body with grooved end connections • 6" (150 mm) welded steel body with grooved end connections • 8" (200 mm) welded steel body with grooved end connections having all brass and galvanized trim. The manifold pip- ing shall clearly identify the manifold's pipe size, flow di- rection, UL Listing/ULC Listing/ FM Approval, drain, and gauge outlets. A built-in drain port shall be available to permit hydrostatic testing without draining the system. 5. Model CR Commercial Riser Threaded End Assemblies (1-1/2" [40mm] &2" [50mm]) • THREADED ENDS ASSEMBLIES (1-1/2"(40MM) &2"(50MM) ONLY) - B B D - D-- - 3-WAY 3-WAY REDUCINGVALVE PRESSURE VALVE TEE RELIEF - 1 ojc5 „ �����ii�l1; ■i !1 '° '1I', CI I PRESSURE _r ! ' III (TAKE OUT) PRESSURE J mom d K (TAKE OUT) GAUGE GAUGE 1 1 r I: I 1 A 1_I',1 11 A m II\ 'Yu° ict 1111 It_77', skA ,c_ BALL BALL VALVE ..- VALVE WATERFLOW J MANIFOLD C (DRAIN WATERFLOW MANIFOLD DETECTOR BODY CONNECTION) DETECTOR BODY CONNECTION) BASIC ASSEMBLY(2"(50MM)VERSION SHOWN) BASIC ASSEMBLY WITH PRESSURE RELIEF KIT (2"(50MM)VERSION SHOWN) B PRESSURE D GAUGE 3-WAY VALVE 'Nit ' . I ilk, co. Ili_onowilt A E /f_-. 01 fii relligi (TAKE OUT) isir- ! Sae MI 4 !0''I) 1 VALVE (DRAIN i CONNECTION) WATERFLOW MANFOLD C DETECTOR BODY BASIC ASSEMBLY WITH TEST AND DRAIN VALVE &PRESSURE RELIEF KIT (2"(50MM)VERSION SHOWN) 615FGO1E (TEST AND DRAIN SHOWN IN°TEST"POSITION) Fig. 1 2. GROOVED ENDS ASSEMBLIES(2"(50MM),2-1/2°(65MM),3"(80MM),4°(100MM),6"(150MM),&8"(200MM)) B B D D 3-WAY 3-WAY VALVE VALVE -\ l A STREET r� STREET �! ELBOW !� ■�1! ELBOW �Li .l�) ea.I� 111:1L:111 aewa . � � . � \ PRESSURE PRESSURE, 'I PRESSURE, �q. RELEF GAUGE •••••IS �.�_ GAUGE Q k* IKIT A !� r i,',, E A r '''''I�'�` E �i1���> .'�'. I y :: imm.,.7a, (TAKE OUT) . (TAKE OUT) 1:21. E. WATERFLOW._ MAN FOLD SALVE ALL 1 WATERFLOWJ MANFOLDJ I , 1 DETECTOR BODY ---C (DRAIN DETECTOR BODY (',' �, CONNECTION) I I BALL VALVE BASIC ASSEMBLY(3"(80MM)VERSION SHOWN) C (DRAIN (SEE TABLE 1.) CONNECTION) BASIC ASSEMBLY WITH PRESSURE RELIEF KIT (3"(80MM)VERSION SHOWN)(SEE TABLE 1.) - B B D - 3-WAY PRESSURE D VALVE 1 GAUGE 3-WAY — VALVE +1 461 y" 11,141tt Al1I 'cul' (II \� PRESSURE II E —GAUGE E (TAKE OUT) (TAKE OUT) - J ) - _ Irip Cl ' i AV A I / // WATERFLOW_TMANFOLD/ r I *-- ... WATERFLOWJ MANFOLDJ DETECTOR BODY I I DETECTOR BODY � I C `VALVE 7 ilk ) \ (DRAINI I CONNECTION) VALVE BASIC ASSEMBLY WITH TEST AND DRAIN VALVE C-' (DRAIN (4"(100MM)VERSION SHOWN)(SEE TABLE 2.) BASIC ASSEMBLY WITH TEST AND DRAIN VALVE CONNECTION) (TEST AND DRAIN SHOWN IN°OFF"POSITION) &PRESSURE RELIEF KIT (4°(100MM)VERSION SHOWN)(SEE TABLE 2.) (TEST AND DRAIN SHOWN IN'OFF'POSITION) 611F0028 Fig. 2 3. Table 1 Dimensions&Weights Basic Assembly Basic Assembly with Pressure Relief Kit Manifold A B C D E Weight A B C D E Weight Pipe Size in(mm) in(mm) in(mm) in(mm) in(mm) lbs(kg) in(mm) in(mm) in(mm) in(mm) in(mm) lbs(kg) in(mm) Threaded 11/20p) 11 111/2 3 73/4 81/4 8.3 121/2 113/4 3 73/4 81/4 10.4 Ends (279) (292) (76) (197) (210) (3.8) (318) (298) (76) (197) (210) (4.7) (See Fig.1) 2(50) 11 121/4 31/4 8 81/4 9.1 121/2 121/2 31/4 8 81/4 11.2 (279) (311) (83) (203) (210) (4.1) (318) (318) (83) (203) (210) (5.1) 2(5°I123/4 13' 33/4 8 13 10.7 123/4 13'/4 33/4 8 13 13.3 (324) (337) (95) (203) (330) (4.9) (323) (337) (95) (203) (330) (6.0) 21/2 123/4 141/4 41/4 81/4 13 12.9 123/4 141/4 41/4 81/4 13 16.7 _ (65) (324) (362) (108) (210) (330) (5.9) (323) (362) (108) (210) (330) (7.6) Grooved 3(80) 123/4 143/4 41/2 81/2 13 17.6 123/4 143/4 41/2 81/2 13 18.3 Ends (324) (375) (114) (216) (330) (8.0) (323) (375) (114) (216) (330) _ (8.3) (See Fig. 2) 4(100) 121/2 163/4 51/2 9 13 21.3 121/2 163/4 51/2 9 13 26.7 ' (318) (425) (140) (229) (330) (9.7) (318) (425) (140) (229) (330) (12) 6(150) 121/2 201/4 8 10 13 26.3 121/2 201/4 8 10 13 31.8 (318) (514) (203) (254) (330) (12) (318) (514) (203) (254) (330) (14.4) 8(200) 121/2 221/4 9 11 13 31.0 121/2 221/4 9 11 13 36.5 (318) (565) (229) (280) (330) (14.1) (318) (565) (229) (280) (330) (16.6) Dimensions&Weights Table 2 Basic Assembly with Test and Drain Valve Basic Assembly with Test and Drain Valve&Pressure Relief Kit Manifold A B C D E Weight A B C D E Weight Pipe in p Sizem) in(mm) in(mm) in(mm) in(mm) in(mm) lbs(kg) in(mm) in(mm) in(mm) in(mm) in(mm) lbs(kg) Threaded 11/2(40) 11 161/2 3 73/4 81/4 10.0 143/4 161/2 3 73/4 81/4 10.8 Ends (279) (419) (76) (197) (210) (4.5) (375) (419) (76) (197) (210) (4.9) (See Fig.1) 2(50) 11 17 31/4 8 81/4 10.8 143/4 17 31/4 8 81/4 11.6 (279) (432) (83) (203) (210) (4.9) (375) (432) (83) (203) (210) (5.3) 2(5°I123/4 19 33/4 8 13 10.7 151/4 19 33/4 8 13 13.3 (324) (483) (95) (203) (330) (4.9) (387) (483) (95) (203) (330) (6.0) 21/2(65) 123/4 191/2 41/4 81/4 13 12.9 151/4 191/2 41/4 81/4 13 16.1 (324) (495) (108) (210) (330) (5.9) (387) (495) (108) (210) (330) (7.3) Grooved 3(80) 123/4 201/4 41/2 81/2 13 17.6 151/4 201/4 41/2 81/2 13 17.0 Ends (324) (514) (114) (216) (330) (8.0) (387) (514) (114) (216) (330) (7.7) (See Fig.2) 4(100) 14 231/2 51/2 9 13 25.8 181/4 231/2 51/2 9 13 26 (356) (597) (140) (229) (330) (11.6) (464) (597) (140) (229) (330) , (11,8) 6(150) 14 26 8 10 13 30 181/4 26 8 10 13 31 (356) (660) (203) (254) (330) (13.6) (464) (660) (203) (254) (330) (14.1) 8(200) 141/4 271/2 9 11 13 35.3 181/4 271/2 9 11 13 36.3 (362) (699) (229) (280) (330) (16) (470) (699) (229) (280) (330) (16.5) 4. Ordering Information: Model CR Commercial Riser Assembly Part Number Code Key 1.5NT B 0 1.5MT T28(K-2.8)t1i(2) 1 2NT T42(K-4.2)(1) 2 2MT T56(K-5.6) 3 2G T80(K-8.0)(3) 2.5G T112(K-11.2)(3) 0=Assembly without Pressure Relief Kit 3G T168(K-16.8)12i(3) — Water Detector-cULus&FM 4G 1 =Assembly with Pressure Relief Kit 6G B=Basic Assembly Water Detector-cULus&FM 8G T28=W/K-2.8 Test&Drain Valve 2=Assembly without Pressure Relief Kit 1.5NT= 1'/z'(40 mm) T42=W/K-4.2 Test&Drain Valve Water Detector-ULC NPT Threaded Ends Assembly T56=W/K-5.6 Test&Drain Valve 3=Assembly with Pressure Relief Kit Water Detector-ULC 1.5MT= 11/2"(40 mm) T80=W/K-8.0 Test&Drain Valve Metric Threaded Ends Assembly T112=W/K-11.2 Test&Drain Valve 2NT=2"(50 mm) T168=W/K-16.8 Test&Drain Valve(2)(3) NPT Threaded Ends Assembly 2MT=2"(50 mm) Metric Threaded Ends Assembly (1)Not available for 4",6"and 8"risers. 2G=2"(50 mm) W Not available for 2-1/2"and 3"risers. Grooved Ends Assembly (3)Not available for 172"to 2"risers. 2.5G=2'/2"(65 mm) Grooved Ends Assembly For Grooved end Test and Drain valves (See note 3) 3G=3"(80 mm) Grooved Ends Assembly 4G=4"(100mm) Grooved Ends Assembly 6G=6"(150mm) Grooved Ends Assembly 8G=8"(200mm) Grooved Ends Assembly Example#1: 1.5NT-B-1 (11/2" (40mm) Model CR Commercial Riser Assembly with NPT female inlet and outlet threads, basic trim with separate Pressure Relief Kit). Example#2: 3G-T56-0 (3"(80mm) Model CR Commercial Riser Assembly with grooved ends, basic trim with Test and Drain Valve having a 5.6 K factor, without a Pressure Relief Kit) Example#3: 6G-T80-0 (6"(150mm) Model CR Commercial Riser Assembly with grooved ends, basic trim with Test and Drain Valve having a 8.0 K factor, without a Pressure Relief Kit) Notes: 1. All Model CR Commercial Riser Assemblies come with a 300 psi (20.7 bar) UL Listed and FM Approved pres- sure gauge for 175 psi (12.1 bar) applications. If the Model CR Commercial Riser Assembly is to be installed in a 300 psi (20.7 bar) application, please purchase a 600 psi (41.4 bar) (P/N 98248005) pressure gauge. This gauge may or may not be UL Listed and/or FM Approved at the time of purchase. 2. Unless specified at the time of ordering, pressure relief kits are NOT installed at the factory. This will facilitate hydrostatic testing of the system. When factory installed (see note 3 below) customer acknowledges that the pressure relief valve will operate during normal hydrostatic testing. 3. If required, Pressure Relief Kits may also be installed in the field. Please contact Reliable's Customer Service Department for details. -The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years. _Manufactured by Reliable Automatic Sprinkler Co.,Inc. Recycled 0 483481---61508581Sales Offices Paper IdU (800)(800) Sales Fax (914)8292042 Corporate Offices Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address E.G.Printed in U.S.A.08/18 PM 9999970349 PCTTER Model/Series No. ROEMER VALVES 4060-4076 FIRE PRO. ANGLE HOSE VALVES SERIES Member of Morris Group International SPECIFICATIONS cL us ANGLE VALVES LISTED APP® - FEMALE X MALE Cast brass valve with red hand wheel, Female N.P.T. inlet x Mr male hose thread outlet.300 psi • DOUBLE FEMALE Cast brass valve with red hand wheel. Female N.P.T. inlet $` and outlet. 300 psi .1a ',1•2'i f MODEL 4065 (Shown) - MODEL SELECTION PRODUCT OPTIONS VALVES FINISHES: ❑4060 1-1/2"Female x Male Angle Valve /FMIP- ❑-B Polished Brass ❑4065 2-1/2" Female x Male Angle Valve 1 FM ' ❑-C Rough Chrome Plated ILI 4065-500 2-1/2"Female x Male Angle Valve 500 psi LI-D Polished Chrome Plated ❑4070 1-1/2"Double Female Angle Valve /FM► THREADS: ❑4075 2-1/2"Double Female Angle Valve 41FM10. ❑N.S.T. ❑4075-500 2-1/2"Double Female Angle Valve 500 psi ❑Other OPTIONAL CAPS&FLANGES VARIATIONS: ❑4615 1-1/2"Cap w/Chain ❑Extended Stem Up to 24" ❑4625 2-1/2"Cap w/Chain Specify ❑4711 1 1/2" Flange 3"O.D. ❑Rocker Lugs(Cap Models Only) ❑-GRV Grooved Inlet(4065 Only) ❑4712 2-1/2" Flange 6-1/4"O.D. Call PotterRoemer-Fire Pro for current listings and - POTTER ROEMER/FIRE PRO approvals.Dimensions are subject to manufacturer'sFIRE EQUIPMENT ONFSA Also In: MN tolerance and may change without notice.Potter Roemer- ASASOUFACCIATIONTURERS' Headquarters: - Fire Pro assumes no responsibility for use of void or "^'""'"`"""°"""`"—a"""," P.O.Box 3527 New York(800)526-4592 superceded data.©Copyright Potter Roemer-Fire Pro, "`"" City of Industry,CA Chicago(800)547-3473 Member of Monis Group IntemationalP Please visit Atlanta 800 762-0542 potterroemer.com for most current s specifications. GO �Y AS P ES 91744 U.S.A. ( ) k" Los Angeles Area Miami(866)961-3473 C , r 800-366-3473 Dallas(866)644-3473 4060-4075 SERIES Date: 10/20/15 NFPA® P 626-855-4890 t,yww"potterroemer.com A WARNING:Cancer and Reproductive Harm-www.P65Warnings.ca.gov • 1\ ,.. PCT TER VALVES Model/Series40604075 No. ROEMER . FIRE PRO. ANGLE HOSE VALVES SERIES Member of Morris Group International'"' MODEL DIMENSIONS Closed Open Size A B C C D E • 1-1/2 2-1/4 3-1/2 6-1/2 7-1/2 2-1/2 2 2-1/2 3-1/2 5 9-1/2 11-1/2 3-1/2 2-3/4 ALL DIMENSIONS IN INCHES r-----i B , . 1--r. —..gEn.. .,__ Ark III q mi. ... - NKr .f. 104„ (Open) Niiii II V.,7% r:°> gll (Closed) v hl ,- D ! ll6I1• X MaNFDw+e► ,III) �Iicry 7 ; 1 VIII) '1N =NM 34- 1."--A-` +a NEN. i MODEL 4060-4065 MODEL 4065-GRV I--A -, 'a iiiilZ;1 ilk lima -@- 1111111.6' , illi 'ft.,::-. tit-, –a c sii air s. `"""~�-' 0 Female X Female .'4.-,1* 4 r iii 1 s .. t gulp , i y.--A MODEL 4070-4075 Call Potter Roemer-Fire Pro for current listings and - POTTER ROEMER/FIRE PRO approvals.Dimensions are subject to manufacturer's FIRE EQUIPMENT ����� tolerance and maychange withoutnotice.Potter Roemer- MANUFACTURERS' Headquarters: Also in: g ASSOCIATION 4 Fire Pro assumes no responsibility for use of void or P.O.Box 3527 New York(800)526-4592 superceded data.©Copyright Potter Roemer-Fire Pro, City of Industry,CA Chicago(800)547-3473 Member ofMonds Group International TM Please visit ii 91744 U.S.A. Atlanta(800)762-0542 potterroemer.com for most current specifications. [4] ` '�� - CNASPE Miami(866)961-3473 a AS Los Angeles Area ® ' s 800-366-3473 Dallas(866)644-3473 4060-4075 SERIES Date: 10/20/15 NFPA 9Ef MEMe,A 626-855-4890 www potterroemer.com Model 1011A TESTANDRAIN® Sectional Floor Control Test and Drain Valve for Systems Requiring Pressure Relief Valve TEST 112"ORIFICE PUSH • Irce el t {i t° telk ice/ U- �. (0, 517E IN. MODEL 1011 Sizes: 3%" 1" 114 r 11/2 2" The AGF Model 1011A TESTANDRAIN® provides the test and express drain functions for wet fire sprinkler systems on multi-story installations requiring pressure relief(NFPA 13 and NFPA 13R).The Model 1011A features a Model 7000 Pres- sure Relief Valve with drain pipe. The Model 1011A is available in a full range of sizes (3/" to 2") with NPT connections (BSPT available). The Model 7000 Pressure Relief Valve(UL/FM)features a flushing handle and a 175 PSI factory rating (other pressure ratings available). • Complies with NFPA 13 and NFPA 13R Requirements • Compact, Single-Handle Ball Valve • Tamper-Resistant Test Orifice and Sight Glasses • 300 PSI rated. • Specifiable orifice sizes: 3/e" (2.8K), 7/16" (4.2K), 1/2" (5.6K), 17/22" (8.0K), 5/e" (11.2K, ELO), 3A" (14.0K, ESFR), and K25 • Relieves Excess System Pressure caused by Surges or Temperature Changes • Shipped with Relief Valve and Bypass Drain Ports Plugged to Expedite Pressure Testing • Locking Kit Available Repair kits are available for all TESTANDRAIN® valves. Kit includes: Adapter Gasket (1), Ball (1), Valve Seats (2), Stem Packing (1), and Stem Washer(1). Valve and orifice size must be specified when ordering. NOTE: It is important to note that the pressure rating of the relief valve indicates an operating range of pressure for both opening and closing of the valve. Standard relief valves are required to OPEN in a range of pressure between 90%and 105%of their rating.The valves are required to CLOSE at a pressure above 80%of that rating.The relief valve should be installed where it is easily accessible for maintenance.Care should be taken that the relief valve CANNOT be isolated from the system when the system is operational.A relief valve should NEVER have a shutoff valve or a plug downstream of its outlet. Reliability, Versatility, Code Compatibility SS-M1011A_V001•06/13 TESTANDRAIN®is a registered trademark of AGF Manufacturing Inc. Model 1011A co rLISTED TESTA N DRAIN° ® Model 1011A 300 PSI Bronze Ball Valve, Model 7000 Pressure Relief Valve APPROVED Factory Rated at 175 PSI with other setting available Dimensions Model 1011A - Front View SIZE A B C D E F G H A u u n u u u u El INLET y 79/16 11/2" 23/46 35/8 33/8 113/46 49/16 63/8 , lel in (191 mm) (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) {117 mm) (162.5 mm) F TO \/ 79/16" 11/2" 23/16" 35/8" 33/8" 113/16" 49/16" 63/8" D e�, j, :t�i'1M 1 (191 mm) (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) H .� odamill® " 1 715/16" 111A6" 29/16" 41/4" 35/8" 115/16" 59/16" 71/2" G 11/4" ....L_. +il (201 mm) (43 mm) (65 mm) (108 mm) (91 mm) (51 mm) (141 mm) (192 mm) 1111 815/16" 113/16" 31/4" 51A6" 37/8" 25/8" 81/4" 107/8" 11/2 (227 mm) (45 mm) (81.5 mm) (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) 815/16" 113/16" 31/4" 51/6" 30" 25/8" 81/4" 100" Model 1011A - Plan View 2 (227 mm) (45 mm) (81.5 mm) (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) A The Model 1011A provides the following... To I B .tai From the 2013 Edition of NFPA 13 DRAIN D + �______ • _ ��/ mow Chapter 8.16.2.4.1* Provisions shall be made to properly drain all parts of the system. t �O J,g Chapter 8.16.2.4.2 Drain connections, interior sectional or floor control valve(s)— I &8.16.2.4.3 shall be provided with a drain connection having a minimum _ _ size as shown in Table 8.16.2.4.2. Chapter 8.16.2.4.4 Drains shall discharge outside or to a drain capable of handling the flow of the drain. Orifice Sizes Chapter A.8.17.4.2 (\Net Pipe System)test connection is permitted to terminate into a 3/8, '/,6",1/2", "/32",SIS" ELO`, drain capable of accepting full flow... using an approved sight test 3/4ESFR', and K25` connection containing a smooth bore corrosion-resistant orifice giving a flow equivalent to one sprinkler... Chapter 8.17.4.2.2 The test connection valve shall be accessible. Materials Chapter 8.17.4.2.4 shall be permitted to be installed in any location... downstream of Handle Steel the waterflow alarm. Stem Rod Brass Chapter 8.17.4.3.1 (Dry Pipe System)a trip test connection not less than 1" in Ball C.P. Brass diameter,terminating in a smooth bore corrosion-resistant orifice, Body Bronze to provide a flow equivalent to one sprinkler... Valve Seat Impregnated Teflon® Chapter 8.17.4.3.2 The trip test connection... with a shutoff valve and plug not less Indicator Plate Steel than 1", at least one of which shall be brass. Relief Valve Bronze Chapter 7.1.2 -a wet pipe system shall be provided with a listed relief valve set Bypass FittingsBrass to operate at 175 PSI or 10 PSI in excess of the maximum system Bypass TubingNylobraid pressure,whichever is greater. Chapter 8.16.1.2.3" A listed relief valve of not less than 1/2" in size shall be provided on Approvals the discharge side of the pressure-reducing valve set to operate at UL and ULC Listed: a pressure not exceeding rated pressure of the system. (EX4019&EX4533) Chapter A.8.16.1.2.3 -consideration should be given to piping the discharge from the (pressure relief)valve FM Approved pos ,� NYC-BSA No.720-87-SM MADE IN N.S.A. - USA Patent # 4741361 and Other Patents Pending AGF Manufacturing Inc. Job Name: 100 Quaker Lane,Malvern, PA 19355 Architect: Phone:610-240-4900 Fax:610-240-4906 Engineer: www.testandrain.com Contractor: *Available on 11/4"to 2"size units only•**Available on 11/2"and 2"size units only tLIILPWorldwide www t co-fire.com Fire Protection Contacts Y Products BLAZEMASTER CPVC Fire Sprinkler Pipe & Fittings Submittal Sheet General Technical Description Data TYCO CPVC Pipe and Fittings pro- Si n ch thru 3 Inch duced by Tyco Fire Protection Prod ucts (TFPP) are designed exclusively Maximum Working Pressure • for use in wet pipe automatic fire 175 psi sprinkler systems. The TYCO CPVC Approvals Pipe and Fittings are produced from UL and C-UL Listed BLAZEMASTER CPVC compound FM Approved . that is a specially developed thermo- LPCB Approved plastic compound composed of post NSF Certified chlorinated polyvinyl chloride (CPVC) MEA Approved ; :. resin and state of the art additives. City of Los Angeles X , TYCO CPVC Pipe and Fittings are (Refer to Installation Handbook IH-1900 k' easier to install than traditional steel dated June 2008 for exact listing/approval pipe systems, and at the same time, information.) provide superior heat resistance and Manufacture Source Installation strength as compared to traditional U.S.A. TYCO CPVC Pipe and Fittings are to CPVC and PVC piping materials used Material be to be installed in accordance with in the plumbing trade. Various adapt- Pipe: Installation Handbook IH-1900 dated ers are available to connect CPVC ASTM F442,SDR 13.5 April 2016. pipe to metallic piping.All female pipe Fittings: thread adapters have brass inserts for ASTM F438(Sch.40) durability. Grooved adapters connect ASTM F439(Sch.80) directly to grooved end valves and ASTM F1970 metallic pipe,with flexible grooved end Color couplings. Orange NOTICE The CPVC Pipe and Fittings produced with BLAZEMASTER CPVC compound described herein must be installed and maintained in compliance with this document and with the applicable standards of the National Fire Protec- tion Association (NFPA), in addition to the standards of any authorities having jurisdiction.Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Page 1 of 2 APRIL 2016 TFP1915 TFP1915 • Page 2 of 2 Care and Limited Maintenance Warranty TYCO CPVC Pipe and Fittings are to be For warranty terms and conditions,visit maintained and serviced in accordance www.tyco-fire.com with this section. Before closing a fire protection system control valve for inspection or main- tenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must first be obtained from the proper authorities and all person- nel who may be affected by this action must be notified. After placing a fire protection system in service,notify the proper authorities and advise those responsible for moni- toring proprietary and/or central station alarms. The owner is responsible for the inspec- tion, testing, and maintenance of their fire protection system and de-vices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any authority having juris- diction.Contact the installing contrac- tor or product manufacturer with any questions. Automatic sprinkler systems should be inspected,tested,and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national codes. GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway,Lansdale,PA 19446 1 Telephone+1-215-362-0700 Copyright©2016 Tyco Fire Products,LP. All rights reserved. tycc BLAZEMASTER is a trademark of The Lubrizol Corporation. Fire Protection Products tqcci I Fire & Building Products Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 Grinnell Grooved Fire Protection Products Fire Protection Submittal Sheet Listing and Approval Information UB VdS (g) el . 11/ Page 1 of 8 MARCH 2011 TFP1800 Page 2 of 8 TFP1800 Rated Pressure Figure Nominal Size Nominal Size Pipe Schedule Inches mm (psi-UL,ULC,FM;Bar LPCB and VdS) VdS MO UL ® FM �1 O 1'/4,1'/2,2 42.4,48.3,60.3 Sch 5,ID,WST 175 175 175 - - 1'/4,1'/2,2,21/2 42.4,48.3,60.3,73.0 Sch 10,Sch 40 300 300 300 - - 3,4,5,6,8 88.9,114.3,141.3,168.3,219.1 Sch 10,Sch 40 300 300 300 - - 10,12 273.0,323.9 Sch 10,Sch 40 250 250 250 - - 11/4,1 1/2,2,21/2,3 42.4,48.3,60.3,73.0,88.9 MF 300 300 300 - - 4 114.3 MF - - 300 - - - 1'/4,1'/2,2,21/2,3,4 42.4,48.3,60.3,73.0,88.9,114.3 DF 300 300 300 - - 11/4,1 V2,2,21/2,3,4 42.4,48.3,60.3,73.0,88.9,114.3 FLF 300 300 - - - 1'/2,2,21/2,3,4 48.3,60.3,73.0,88.9,114.3 FF 300 300 300 - - 1,1'/4,1'/2,2 33.7,42.4,48.3,60.3 MLT,EZT 300 300 300 - - 3 88.9 EZ 300 300 300 - - 4 114.3 EZ 250 250 300 - - # , '''': 6 168.3 EZ 250 250 175 - - 11/4,11/2,2 42.4,48.3,60.3 BLT,DT,TL,Gal 7,Gal Flo 300 300 300 - - Figure 705 11/4,11/2,2 42.4,48.3,60.3 GL,MLT,MT,SL,WLS 300 300 - - - 1'/4,1'/2,2 42.4,48.3,60.3 UE - - 175 - - 76.1,165.1 BS1387 300 300 300 - - 42.4,48.3,60.3,76.1,88.9,114.3 BS1387,ISO 4200 - - - 16 20 139.7 BS1387,ISO 4200 - - - 16 - 165.1 BS1387,ISO 4200 - - - - 20 168.3,219.1 ISO 4200 - - - 16 20 108.0,133.0,159.0 ISO 4200 300 - 300 - - 216.3 JIS G3452 300 - 300 - - 1'/2,2,21/2 48.3,60.3,73.0 Sch 5, UE,WST 175 175 175 - - 11/2,2,21/2,3,4,5 48.3,60.3,73.0,88.9,114.3,141.3 Sch 10 450 450 450 - - 6,8,10,12 168.3,219.1,273.0,323.9 Sch 10 450 450 450 - - - 11/2,2,21/2,3,4,5 48.3,60.3,73.0,88.9,114.3,141.3 Sch 40 500 500 500 - - 6,8,10,12 168.3,219.1,273.0,323.9 Sch 40 500 500 500 - - 11/2,2,21/2,3,4 48.3,60.3,73.0,88.9,114.3 MF,DF,FF,SF,STF 300 300 300 - - • 2 60.3 EZT 300 - - - - 3 88.9 EZ 300 300 300 - - 0{ 4 114.3 EZ 250 250 300 - 6 168.3 EZ 250 250 175 ti.l' 1'/2,2,21/2,3 48.3,60.3,73.0,88.9 XL 300 300 300 - - 1'/2,2 48.3,60.3 GL,MT,MLT,TL 300 300 300 - - 11/2,2 48.3,60.3 Gal 7,Gal Flo 300 300 300 - - Figure 707 11/2,2 48.3,60.3 BLT,DT - - 300 - - 14,16 355.6,406.4 Sch 30 300 - - - - 18,20 457.2,508.0 Sch 30 200 - - - - 24 610.0 Sch 20 250 - - - - 76.1,165.1 BS1387,ISO 4200 300 - 300 - 20 48.3,60.3,88.9,114.3,168.3 BS1387,ISO 4200 - - - - 20 219.1,273.0,323.9 ISO 4200 - - - 16 20 2 60.3 Sch 5,ID,UE,WST 175 175 175 - - 2,21/2,3,4,5 60.3,73.0,88.9,114.3,141.3 Sch 10,Sch 40 250 250 250 - - 6,8 168.3,219.1 Sch 10,Sch 40 250 250 250 - - 10,12 273.0,323.9 Sch 40 250 250 250 - - • • • 2 60.3 BLT,DT,EZT,FF,GL,LS 250 250 250 - - 2 60.3 MT,MLT,TL,WLS,XL 250 250 250 - - • • 2 60.3 Gal 7,Gal Flo 250 250 250 - - 2 60.3 MF,FF - - 250 - - ' • 2,21/2,3,4 60.3,73.0,88.9,114.3 DF,FF,MF,SF 250 250 250 - - 3,4 88.9,114.3 EZ 250 250 250 - - Figure 71 6 168.3 EZ 250 250 175 - - 2,3,4 60.3,88.9,114.3 STF 250 250 250 - - 21/2,3 73.0,88.9 XL 250 250 250 - - 60.3,76.1,88.9,114.3,168.3 BS1387,ISO 4200 250 - 250 16 20 139.7 BS1387,ISO 4200 250 - 250 16 - Figure 71 PN16 165.1 BS1387,ISO 4200 250 - 250 - 20 219.1,273.0 ISO 4200 250 - 250 - 20 323.9 ISO 4200 250 - 250 - 16 TFP18O0 Page 3 of 8 Rated Pressure Figure Nominal Size Nominal Size Pipe Schedule (psi-UL,ULC,FM;Bar LPCB and VdS) Inches mmUL ® FM VdS OM 11/4,11/2,2 42.4,48.3,60.3 Sch 5,ID,UE,WST 175 175 175 - - 11/4 42.4 Sch 10,Sch 40 300 300 300 - - 11/2,2,21/2,3,4 48.3,60.3,73.0,88.9,114.3 Sch 10,Sch 40 500 500 500 - - 5,6 141.3,168.3 Sch 10 300 300 300 - - 8 219.1 Sch 10 400 400 400 - - 5 141.3 Sch 40 300 300 300 - - 6 168.3 Sch 40 400 400 400 - - _ 8 219.1 Sch 40 450 450 450 - - 10,12 273.0,323.9 Sch 10,Sch 40 250 250 250 - - 11/4,11/2,2,21/2,3 42.4,48.3,60.3,73.0,88.9 MF 300 300 300 - - 4 114.3 EZ,MF 250 250 300 - - 3 88.9 EZ 300 300 300 - - 6 168.3 EZ 250 250 300 - - 11/2,2,21/2,3,4 48.3,60.3,73.0,88.9,114.3 DF,STF 300 300 300 - - 0 11/4,11/2,2,21/2,3 42.4,48.3,60.3,73.0,88.9 FLF 300 300 - - - 4 114.3 FLF 250 250 - - - Figure 772 11/2,2,21/2,3 48.3,60.3,73.0,88.9, FF 300 300 300 - - Patented 4 114.3 FF 250 250 300 - - 11/4,11/2,2 42.4,48.3,60.3 EZT,MT,MLT,WLS 300 300 300 - - 11/4,11/2,2 42.4,48.3,60.3 GL,Gal 7,Gal Flo 300 300 300 - - 11/2,2 48.3,60.3 BLT,DT 300 300 300 - - 11/2,2 48.3,60.3 IL,XL 300 300 - - - 76.1,165.1 BS1387 300 300 300 - - 42.4,48.3,60.3,76.1,88.9,114.3 BS1387,ISO 4200 - - - 16 20 139.7 BS1387,ISO 4200 - - - 16 - 165.1 BS1387,ISO 4200 - - - - 20 168.3,219.1,273.0,323.9 ISO4200 - - - 16 20 - 2 x11/2,21/2x 2,3 x 2 60.3 x 48.3,73.0 x 60.3,88.9 x 60.3 Sch 5 175 175 175 - - 3 x 21/2,4x 2,4 x 21/2 88.9 x 73.0,114.3 x 60.3,114.3 x 73.0 Sch5 175 175 175 - - 2 x 11/2,21/2x 2,3 x 2 60.3 x 48.3,73.0 x 60.3,88.9 x 60.3 Sch 10,Sch 40 350 350 350 - - - 3x21/2,4x2,4x2'/2 88.9 x 73.0,114.3 x 60.3,114.3 x 73.0 Sch 10,Sch 40 350 350 350 - - 4 x 3,5 x 4 114.3 x 88.9,141.3,114.3 Sch 10,Sch 40 350 350 300 - - 6 x 4,6 x 5 168.3 x 114.3 x 1638.3 x 141.3 Sch 10,Sch 40 350 350 300 - - 8 x 6 219.1 x 168.3 Sch 40 350 350 300 - - 2 x 11/2,21/2x 2,3 x 2 60.3 x 48.3,73.0 x 60.3,88.9 x 60.3 OF,EZT,FF,GL,MF 300 300 300 - - 2 x11/2,21/2 x 2,3 x 2 60.3 x 48.3,73.0 x 60.3,88.9 x 60.3 MT,MLT,SF,STF,TL 300 300 300 - - 4 .. ' 4 4 x 2 114.3 x 60.3 DF,EZT,FF,GL,MF 300 300 300 - - 4 x 2 114.3 x 60.3 MT,MLT,SF,STF,TL 300 300 300 - - f 4I 3 x 21/2,4 x 21/2,4 x 3 88.9 x 73.0,114.3 x 73.0,114.3 x 88.9 DF,MF,SF 300 300 300 - - 1 . —"", I 4x21/2,4x3 114.3 x 73.0,114.3 x 88.9 FF,STF 300 300 300 - - 5 x 4,6 x 4 141.3 x 114.3,168.3 x 114.3 DF,FF,SF,STF 300 300 300 - - Figure 716 3x 2,3x 21/2 88.9 x 60.3,88.9 x 73.0 EZ 300 300 300 - - 2 x 11/2 60.3 x 48.3 Gal 7,Gal Flo 300 300 300 - - 60.3 x 48.3,73.0 x 60.3,88.9 x 60.3 BS1387,ISO 4200 300 , - 300 16 20 88.9 x 76.1,114.3 x 60.3,114.3 x 76.1 BS1387,ISO 4200 300 - 300 16 20 114.3 x 88.9 BS1387,ISO 4200 , 300 - 300 16 20 168.3 x 114.3,219.1 x 168.3 ISO 4200 300 - 300 16 20 139.7 x 114.3 BS1387,ISO 4200 300 - 300 16 - 165.1 x 114.3 BS1387,ISO 4200 300 - 300 - 20 11/4,11/2,2 x1/2,3/4,1 42.4,48.3,60.3 x 21.3,26.7,33.7 Sch 5,Sch 10,Sch 40 175 175 175 - - 11/4,11/2,2 x 1/2,3/4,1 42.4,48.3,60.3 x 21.3,26.7,33.7 BLT,DF,DT,GL,LS,MF 175 175 175 - - 11/4,11/2,2 x1/2,3/4,1 42.4,48.3,60.3 x 21.3,26.7,33.7 MT,MLT,TL,WLS,XL 175 175 175 - - t 11/4,11/2,2 x1/2,3/4,1 42.4,48.3,60.3 x 21.3,26.7,33.7 Gal 7,Gal Flo 175 175 175 - - 11/4,11/2 x 1/2,3/4,1 42.4,48.3 x 21.3,26.7,33.7 EZT 175 175 175 - 1'/2x'/2,3/4,1 48.3 x 21.3,26.7,33.7 FF 175 175 175 - - 4. 21/2x1/2,3/4,1 73.0 x 21.3,26.7,33.7 Sch 10,Sch 40 175 175 175 - - Figure 40-5• 272 x1/2,3/4,1 73.0 x 21.3,26.7,33.7 DF,MF,STF,XL 175 175 175 - - _ 112,2 x1/2,3/4,1 48.3,60.3 x 21.3,26.7,33.7 STF 175 175 175 - - • Figure 40-5 Straps are UL and ULC Listed and FM Approved with NPT and ISO threaded outlets as specified in the chart. Page 4 of 8 TFP18OO Rated ' Nominal Size Nominal Size Pipere Figure Inches mm Schedule (psi UL,ULC and FM;bar LPCB and VdS) Pressure 0 CO F> vas (LP(,BJ 2 x'/2,3/4,1,1'/4,1'/2 60.3 x 21.3,26.7,33.7,42.4,48.3 Sch 5 175 175 175 - - 2 x1/2,3/4,1,11/4,11/2 60.3 x 21.3,26.7,33.7,42.4,48.3 Sch 10,Sch 40 300 300 300 - - 21/2 x'/2,3/4,1,1'/4,1'12,2 73.0 x 21.3,26.7,33.7,42.4,48.3,60.3 Sch 10,Sch 40 300 300 300 - - 3,4 x'h,314,1 88.9,114.3 x 21.3,26.7,33.7 Sch 10,Sch 40 300 300 300 - - 4 x 21/2,4 x 3 114.3 x 73.0,4 x 88.9 Sch 10,Sch 40 300 300 300 - - 5 x 2,5 x 2'/2 141.3 x 60.3,141.3 x 73.0 Sch 10,Sch 40 300 300 300 - - 6 x 11/2,2,21/2,3,4 168.3 x 48.3,60.3,73.0,88.9,114.3 Sch 10,Sch 40 300 300 300 - - - 2 x 1/2,3/4,1,1'/4,1'/2 60.3 x 21.3,26.7,33.7,42.4,48.3 BLT,DT,EZT,FF,GL,MF 300 300 300 - - 2 x'/2,3/4,1,11/4,11/2 60.3 x 21.3,26.7,33.7,42.4,48.3 MT,MLT,STF,TL,WLS 300 300 300 - - 2 x1/2,3/4,1,11/4,11/2 60.3 x 21.3,26.7,33.7,42.4,48.3 Gal 7,Gal Flo 300 300 300 - - 2 x'/2,3/4,1 60.3 x 21.3,26.7,33.7 DF 300 300 300 - - ; 2'/2,3,4 x1/2,3/4,1 73.0,88.9,1143 x 21.3,26.7,33.7 DE FF ME STF 300 300 300 - - A, 2 x 11/4,11/2 60.3 x 42.4,48.3 DF 300 300 300 - - - .... 3,4 x 2 88.9,114.3 x 60.3 DF,FF,MF,STF 300 300 300 - - • 4 x 21/2 114.3 x 73.0 OF,FF,MF,STF 300 300 300 - - 4x3 114.3x88.9 FF,MF,STF 300 300 300 - - 76.1 x 21.3,26.7,33.7 BS1387,ISO 4200 300 - 300 16 20 139.7 x 48.3,88.9 BS1387,IS0 4200 300 - 300 16 20 Figure 730 165.1 x 42.4 BS1387,ISO 4200 300 - 300 16 20 Threaded*t 60.3 x 21.3,26.7,33.7,42.4,48.3 BS1387,ISO 4200 - - - 16 20 76.1 x 42.4,48.3,60.3 BS1387,ISO 4200 - - - 16 20 88.9 x 21.3,26.7,33.7,42.4,48.3,60.3 BS1387,ISO 4200 - - - 16 20 114.3 x 21.3,26.7,33.7,42.4 BS1387,ISO 4200 - - - 16 20 114.3 x 48.3,76.1,88.9 BS1387,ISO 4200 - - - 16 20 165.1 x 48.3,60.3,76.1,88.9,114.3 BS1387,ISO 4200 - - - - 20 139.7 x 60.3,76.1 BS1387,ISO 4200 - - - 16 - 168.3 x 48.3,60.3,73.0 ISO 4200 - - - 16 20 168.3,219.1 x 76.1,88.9,114.3 ISO 4200 - - - 16 20 2 x 11/2 60.3 x 48.3 Sch 5 175 175 175 - - 2,21/2,3,4,5,6 x 11/2 60.3,73.0,88.9,114.3,141.3,168.3 x 48.3 Sch 10,Sch 40 300 300 300 - - 3,4,5 x 2,21/2 88.9,114.3,141.3 x 60.3,73.0 Sch 10,Sch 40 300 300 300 - - 4 x 3,5 x 3 114.3 x 88.9,141.3 x 88.9 Sch 10,Sch 40 300 300 300 - - - 6 x 21/2,3,4 168.3 x 48.3,73.0,88.9,114.3 Sch 10,Sch 40 250 250 250 - - 8 x 21/2,3,4 219.1 x 73.0,88.9,114.3 Sch 10,Sch 4.0 300 300 300 - - 2,21/2,3,4 x 11/2 60.3,73.0,88.9,114.3 x 48.3 DF 300 300 300 - - 3,4 x 2 88.9,114.3 x 60.3 DF 300 300 300 - - '" 2 x11/2 60.3 x 48.3 BLT,TL 300 300 300 - - 3 x 11h 88.9 x 48.3 EZ 300 300 300 - - 139.7 x 48.3,88.9 BS1387,ISO 4200 300 - 300 16 20 - I. 165.1 x 42.4,48.3,60.3,76.1 BS1387,ISO 4200 300 - 300 16 20 i I 60.3 x 42.4,48.3 BS1387,ISO 4200 - - - 16 20 76.1 x 42.4,48.3,60.3 BS1387,ISO 4200 - - - 16 20 Figure 730 88.9 x 42.4,48.3,60.3 BS1387,ISO 4200 - - - 16 20 Grooved**$ 114.3 x 42.4,48.3,60.3,76.1,88.9 BS1387,ISO 4200 - - - 16 20 165.1 x 48.3,60.3,76.1,88.9,114.3 BS1387,ISO 4200 - - - - 20 139.7 x 60.3,76.1 BS1387,ISO 4200 - - - 16 - 168.3 x 48.3,60.3,73.0 ISO 4200 - - - 16 20 168.3,219.1 x 76.1,88.9,114.3 ISO 4200 - - - 16 * Figure 730 Threaded Mechanical Outlets are UL and ULC Listed and FM Approved in both the Tee and Cross configuration with NPT and ISO threaded outlets as specified in the chart. **Figure 730 Grooved Mechanical Outlets are UL and ULC Listed and FM Approved in both the Tee and Cross configuration. $ Figure 730 Threaded and Grooved Mechanical Outlets are VdS Approved in the Tee configuration only. Grinnell®products are UL and ULC Listed and FM, LPCB and VdS Approved,as specified in the charts,for the pressure ratings shown for use in Fire Protection Systems(automatic sprinkler,open sprinkler and standpipe)and connections to such systems. The charts were developed from the latest Listings and Approval data available at the time of publication. Listings are subject to changes and additions by the approval bodies. For Dry Pipe systems or Freezer Systems, use Tri-Seal Gaskets and petroleum free silicone lubricant. Follow installation instructions provided in the Installation Handbook IH-1000. TFP1800 Page 5 of 8 Rated Pressure Figure Nominal Size Nominal Size Pipe Schedule Inches mm (psi-UL,ULC,FM;Bar LPCB and VdS) OL ® 0 Vds) [LJ 1-1/4,1-1/2,2 42.4,48.3,60.3 FLF,MF,XL,GL, 40,CT,OF,TL, 300 300 300 WLS,MT,MLT 2-1/2,3,4 73.0,88.9,114.3 FLF,MF,DF 300 300 300 2-1/2,3 73.0,88.9 FF,XL 300 300 300 1-1/4,1-1/2,2, 42.4,48.3,60.3,73.0,88.9,114.3, 10 300 300 300 2-1/2,3,4,6,8 168.3,219.1 1-1/4,1-1/2,2, 42.4,48.3,60.3,73.0,88.9,114.3, 40 300 300 300 2-1/2,3,4,6 168.3 1,1-1/4,1-1/2,2 33.7,42.4,48.3,60.3 5 175 175 175 3,4,6 88.9,114.3,168.3 EZF 300 300 300 1 1/4 42.4 EZT 300 300 300 0 1-1/2,2 48.3,60.3 EZT,FF 300 300 300 1-1/2,2,2-1/2,3,4 48.3,60.3,73.0,88.9,114.3 STF 300 300 300 4 114.3 STF 250 250 250 8 219.1 0.188 in.wall 300 300 300 10,40,XL,IL,DF,BLT,DL,DT,MT, 1 33.7 WLS,WST,GL,MLT,EZT,ET,EL,5, 300 300 300 Figure 577 BS1387M,ISO 4200 5 141.3 10 300 300 300 5 141.3 40 300 300 300 76.1 mm,165mm BS1387M,ISO 4200 300 300 139.7mm ISO 4200 300 300 1,1-1/4,1-1/2,2,3,4 33.7,42.4,48.3,60.3,88.9,114.3 BS1387M,ISO 4200 20 bar 76.1,165.1 BS1387M,ISO 4200 20 bar 6,8 168.3,219.1 ISO 4200 20 bar - 1,1-1/4,1-1/2,2,3, 33.7,42.4,48.3,60.3,88.9,114.3, ISO 4200 16 bar 4,6,8 168.3,219.1 76.1,139.7 ISO 4200 16 bar PipeSchedule Ke MF-Mega Flow Listed/Approved steel sprinkler pipe p Y manufactured by Wheatland Tube Company. STF-Steady Flow Listed/Approved steel sprinkler pipe manu- MLT-Mega Light Listed/Approved steel sprinkler pipe manu- factured by AMS Tube Corp. factured by Wheatland Tube Company. BLT-Black Light Wall Threadable Listed/Approved steel sprin- MT-Mega Thread Listed/Approved steel sprinkler pipe manu- kler pipe manufactured by Allied Tube and Conduit. factured by Wheatland Tube Company. DF-Dyna-Flow Listed/Approved steel sprinkler pipe manufac- SL-Listed/Approved steel sprinkler pipe manufactured by tured by Allied Tube and Conduit. Wheatland Tube Company. DT-Dyna-Thread Listed/Approved steel sprinkler pipe manu- WLS-WLS Listed/Approved steel sprinkler pipe manufactured factured by Allied Tube and Conduit. by Wheatland Tube Company. SF-Super-Flow Listed/Approved steel sprinkler pipe manu- WST-WST Listed/Approved steel sprinkler pipe manufactured factured by Allied Tube and Conduit. by Wheatland Tube Company. XL-Extra Light Weight Listed/Approved steel sprinkler pipe GL-GL Listed/Approved steel sprinkler pipe manufactured by manufactured by Allied Tube and Conduit. Wheatland Tube Company. UE-Ultra-Eddy Listed/Approved steel sprinkler pipe manufac- EZT-EZ Thread Listed/Approved steel sprinkler pipe manu- tured by Bull Moose Tube Company. factured by Youngstown Tube Company. TL-TL Listed/Approved steel sprinkler pipe manufactured by FF-Fire-Flo Listed/Approved steel sprinkler pipe manufac- Central Grooved Piping Products. tured by Youngstown Tube Company. LS-Listed/Approved steel sprinkler pipe manufactured by 5 -Schedule 5 steel sprinkler pipe Century Tube Corporation. 10-Schedule 10 steel sprinkler pipe ID-IDOD Listed/Approved steel sprinkler pipe manufactured 20-Schedule 20 steel sprinkler pipe by IDOD Systems. 30-Schedule 30 steel sprinkler pipe GAL-FLO-Listed/Approved steel sprinkler pipe manufactured 40-Schedule 40 steel sprinkler pipe by IDOD Systems. BS1387m-British Standard Medium Listed/Approved steel GAL-7-Listed/Approved steel sprinkler pipe manufactured by sprinkler tube. IDOD Systems. IS04200-ISO Standard Listed/Approved steel sprinkler tube. EZ-EZ-Flow Listed/Approved steel sprinkler pipe manufac- JIS G3452 Japanese International Standard tured by Northwest Pipe and Casting Company. FLF-Fire Line Flow Listed/Approved steel sprinkler pipe man- Note: Cut and roll grooved references are for pipe runs and ufactured by Western International Forest Products. also grooved outlets. ' Page 6 of 8 TFP18OO Rated Pressure Figure Nominal Size Nominal Size (psi-UL,ULC,FM;Bar LPCB and VdS) Inches mm UD ) <> VdS Ipco 11/2 x 1/2,3/4,1 42.4 x 21.3,26.7,33.7 300 300 300 - - Figure ADACAP® ,, ADACAP®* 2 xi/2,3/4,1 48.3 x 21.3,26.7,33.7 300 300 300 - - ; y, 21/2 x 1/2,3/4,1 60.3 x 21.3,26.7,33.7 300 300 300 - - 1 33.7 500 500 500 - - 11/4,11/2,2,3,4 42.4,48.3,60.3,88.9,114.3 500 500 500 16 20 6,8 168.3,219.1 500 500 500 16 20 10 273.0 450 450 450 16 20 Figure 12 323.9 450 450 400 16 20 201 21/2,5 73.0,141.3 500 500 500 - - 76.1 500 - 500 16 20 165.1 500 - 500 - 20 Figure 201 139.7 500 - 500 16 - 45°Elbow 108.0,133.0,159.0,216.3 300 - 300 - - 1 33.7 500 500 500 - - 11/4,11/2,2,3,4 42.4,48.3,60.3,88.9,114.3 500 500 500 16 20 6,8 168.3,219.1 500 500 500 16 20 10 273.0 450 450 450 16 20 Figure 12 323.9 450 450 400 16 20 210 21/2,5 73.0,141.3 500 500 500 - - Figure 210 , . 1: 76.1 500 - 500 16 20 90°Elbow 165.1 500 - 500 - 20 139.7 500 - 500 16 - 108.0,133.0,159.0,216.3 300 - 300 - - 1 33.7 500 500 500 - - 11/4,11/2,2,3,4 42.4,48.3,60.3,88.9,114.3 500 500 500 16 20 6,8 168.3,219.1 500 500 500 16 20 10 273.0 450 450 450 16 20 Figure 12 323.9 450 450 400 16 20 219 21/2,5 73.0,141.3 500 500 500 - - 76.1 500 - 500 16 20 165.1 500 - 500 - 20 Figure 219 139.7 500 - 500 16 - Tee 108.0,133.0,159.0,216.3 300 - 300 - - 11/4,11/2,2,3,4 42.4,48.3,60.3,88.9,114.3 500 500 500 16 20 6,8 168.3,219.1 500 500 500 16 20 10 273.0 450 450 450 16 20 Figure 12 323.9 450 450 400 16 20 260 21/2,5 73.0,141.3 500 500 500 - - 76.1 500 - 500 16 20 Figure 260 165.1 500 - 500 - 20 End Cap 139.7 500 - 500 16 - 11/2,x 1,2 x 1 48.3 x 33.7,60.3 x 33.7 500 500 500 16 - 2 x 11/4,2 x 11/2 60.3 x 42.4,60.3 x 48.3 500 500 500 16 20 21/2 x 2,3 x 21/2,4 x 2'/2 73.0 x 60.3,88.9 x 73.0,114.3 x 73.0 500 500 500 16 20 4 x 2,6 x 2 114.3 x 60.3,168.3 x 60.3 500 500 500 16 - 3 x 2,4 x 3,6 x 4 88.9 x 60.3,114.3 x 88.9,168.3 x 114.3 500 500 500 16 20 Figure 5 x 4,6 x 5 141.3 x 114.3,168.3 x 141.3 500 500 500 - - 250 76.1 x 48.3,76.1 x 60.3 500 500 500 16 20 Figure 250 88.9 x 76.1,114.3 x 76.1 500 500 500 16 20 Concentric Istp4, , ,,, 139.7 x 88.9,139.7 x 114.3 500 500 500 16 - Reducer 165.1 x 114.3 500 500 500 - 20 168.3 x 76.1,168.3 x 139.7 500 500 500 16 - 165.1 x 88.9,165.1 x 139.7 500 - 500 - - * ADACAPs are UL and ULC Listed and FM Approved with NPT and ISO threaded outlets. TFP18O0 Page 7 of 8 • Rated Pressure Figure 501 Nominal Size Nominal Size ° Fi ure (psi UL,ULG,FM;Bar LPCB and VdS) 45°Elbow - a g Inches mm UE EC <>, vas LPCB] 11/4,11/2,2,3,4 42.4,48.3,60.3,88.9,114.3 300 300 300 16 20 6,8 168.3,219.1 300 300 300 16 20 Figure 21/2,5 73.0,141.3 300 300 300 - - 501 76.1 300 300 300 16 20 139.7 300 300 300 16 - Figure 510 165.1 300 300 300 - 20 90°Elbow ''' 11/4,11/2,2,3,4 42.4,48.3,60.3,88.9,114.3 300 300 300 16 20 6,8 168.3,219.1 300 300 300 16 20 Figure 21/2,5 73.0,141.3 300 300 300 - - 510 76.1 300 300 300 16 20 139.7 300 300 300 16 - 165.1 300 300 300 - 20 1'/4,11/2,2,3,4 42.4,48.3,60.3,88.9,114.3 300 300 300 16 20 6,8 168.3,219.1 300 300 300 16 20 Figure 519Figure 21/2,5 73.0,1413 300 300 300 - - Tee 519 76.1 300 300 300 16 20 139.7 300 300 300 16 - 165.1 300 300 300 - 20 2,3,4,6,8 60.3,88.9,114.3,168.3,219.1 300 300 300 16 20 Figure 501S 21/2,5 73.0,141.3 300 300 300 - - lift' Figure . 45°Elbow501 S 76.1 300 300 300 16 20 //1°1 139.7 300 300 300 16 - 165.1 300 300 300 - 20 Z 2,3,4,6,8 60.3,88.9,114.3,168.3,219.1 300 300 300 16 20 21/2,5 73.0,141.3 300 300 300 - - Figure 76.1 300 300 300 16 20 5105 139.7 300 300 300 16 - Figure 510S165.1 300 300 300 - 20 90°Elbow ,` ' 2,3,4,6,8 60.3,88.9,114.3,168.3,219.1 300 300 300 16 20 21/2,5 73.0,141.3 300 300 300 - - Figure 76.1 300 300 300 16 20 519S 139.7 300 300 300 16 - 165.1 300 300 300 - 20 , Figure 21/2,3,4,5 73.0,88.9,114.3,141.3 300 300 300 - - 510DE 6,8 168.3,219.1 300 300 300 - - F 1 ., I12 ,; 0"4 Figure 519S Tee Figure 510DE Y'' Drain Elbow :1', ,, s .$ ' TFP1800 Page 8 of 8 Fabricated Fittings Rated Pressure Rated Pressure Figure Nominal Size (psi) Nominal Size (psi) Inches O FM Figure Inches O 0 L UL FM 1,11/4,11/2 300 300 11/4,11/2 300 300 9 2,21/2 300 300 Figure 391 2,21/2 300 300 Groove x Male Threaded 3,4,5 300 300 Figure 321 Adapter Nipples 6,8 300 300 Reducing Tee 3,4,5 300 300 10,12 300 300 6,8 300 300 10,12 300 300 1,1/4,11/2 300 300 300 300 2,21/2 300 300 1,1Y,1'/2 Figure 3922,21/2 300 300 Groove x Groove 3,4,5 300 300 Figure 327 Adapter Nipples6,8 300 300 Cross 3,4,5 300 300 6,8 300 300 10,12 300 300 10,12 300 300 1,11/4,11/2 300 300 1,1'/4,1% 300 300 Figure 393 2,2'1 300 300 Figure 341 2,21/2 300 300 Groove x Bevel 3,4,5 300 300 Groove 3,4,5 300 300 Adapter Nipples 6,8 300 300 Flange Adapter 150 lbs. 6,8 300 300 10,12 300 300 10,12 300 300 11/4.11/2 300 300 11/4,1% 300 300 2,212 300 300 Figure 350 2,21/2 300 300 Figure 312 3,4,5 300 300 Concentric 2212°Elbow 3,4,5 300 300 6,8 300 300 Groove x Groove Reducer 6,8 300 300 10,12 300 300 10,12 300 300 11.11/2 300 300 2,212 300 300 Figure 313 3,4,5 300 300 111/4°Elbow 6,8 300 300 10,12 300 300 General Notes: It is the Designer's responsibility to select products suitable for the intended service and to en- ISO sure that pressure ratings and performance data is not exceeded. Always read and understand the installation = 9001 instructions(IH-1000). Never remove any piping component or correct or modify any piping deficiencies without S, first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. Certified Company TYCO FIRE&BUILDING PRODUCTS,451 North Cannon Avenue,Lansdale Pennsylvania 19446 • VSR P POTTER VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD UL,CUL and CSFM Listed,FM Approved,LPCBApproved,For CE Marked(EN12259-5)/VdSApproved model use VSR-EU Service Pressure: 450 PSI(31 BAR)-UL Flow Sensitivity Range for Signal: 4-10 GPM(15-38 LPM)-UL - Maximum Surge: 18 FPS(5.5 m/s) Contact Ratings: Two sets of SPDT(Form C) 10.0 Amps at 125/250VAC ' 2.0 Amps at 30VDC Resistive 10 mAmps min.at 24VDC a _ `°'F Conduit Entrances: Two knockouts provided for 1/2"conduit. Individual switch compartments suitable for dissimilar voltages. Environmental Specifications: • NEMA 4/IP54 Rated Enclosure suitable for indoor or 0110outdoor use with factory installed gasket and die-cast housing when used with appropriate conduit fitting. • Temperature Range: 40°F-120°F,(4.5°C-49°C)-UL • Non-corrosive sleeve factory installed in saddle. Service Use: Automatic Sprinkler NFPA-13 Specifications subject to change without notice. One or two family dwelling NFPA-13D Ordering Information Residential occupancy up to four stories NFPA-13R Nominal Pipe Size Model Part Number National Fire Alarm Code NFPA-72 2" DN50 VSR-2 1144402 2 1/2" DN65 VSR-2 1/2 1144425 • Installation must be performed by qualified personnel and in - 3" DN80 VSR-3 1144403 accordance with all national and local codes and ordinances. 3 1/2" - VSR-3 1/2 1144435 • Shock hazard.Disconnect power source before servicing.Serious 4" DN100 VSR-4 1144404 injury or death could result. • Risk of explosion.Not for use in hazardous locations.Serious 5" - VSR-5 1144405 injury or death could result. 6" DN150 VSR-6 1144406 8" DN200 VSR-8 1144408 CAUTION �. Optional: Cover Tamper Switch Kit,stock no.0090148 Waterflow switches that are monitoring wet pipe sprinkler systems shall Replaceable Components:Retard/Switch Assembly,stock no. 1029030 not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. Waterflow switches used for this application may result in unintended discharges caused by surges, trapped air,or short retard times. Important: This document contains important information on the installation and operation of the VSR waterflow switches. Please read all instructions carefully before beginning installation. A copy of this document is required by NFPA 72 to be maintained on site. General Information Enclosure The Model VSR is a vane type waterflow switch for use on wet sprinkler The VSR switches and retard device are enclosed in a general purpose, systems.It is UL Listed for use on a steel pipe;schedules 5 through 40, die-cast housing. The cover is held in place with two tamper resistant sizes 2"-6"and is UL Listed and FM Approved for use on steel pipe; screws which require a special key for removal. A field installable schedules 10 through 40, sizes 2"thru 8"(50 mm thru 200 mm).LPC cover tamper switch is available as an option which may be used approved sizes are 2" thru 8" (50 mm thru 200 mm). See Ordering to indicate unauthorized removal of the cover. See bulletin number Information chart. 5401103 for installation instructions of this switch. The VSR may also be used as a sectional waterflow detector on large systems.The VSR contains two single pole,double throw,snap action .. switches and an adjustable,instantly recycling pneumatic retard. The switches are actuated when a flow of 10 GPM(38 LPM)or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 866-956-1211/Canada 888-882-1833 • www.pottersignal.com PRINTED IN USA MFG.#5401146-REV M PAGE 1 OF 4 11/15 VSR P PATTER VANE TYPE WATERFLOW e The Symbol of Protection ALARM SWITCH WITH RETARD Installation (see Fig. 1) These devices may be mounted on horizontal or vertical pipe. On horizontal pipe they shall be installed on the top side of the pipe where they will be accessible. The device should not be installed within 6"(15 cm)of a fitting which changes the direction of the water-flow or within 24" (60 cm)of a valve or drain. NOTE:Do not leave cover off for an extended period of time. Drain the system and drill a hole in the pipe using a hole saw in a slow speed drill (see Fig. 1). Clean the inside pipe of all growth or other material for a distance equal to the pipe diameter on either side of the hole. Roll the vane so that it may be inserted into the hole; do not bend . or crease it. Insert the vane so that the arrow on the saddle points in the direction of the waterflow.Take care not to damage the non-corrosive bushing in the saddle. The bushing should fit inside the hole in the pipe. Install the saddle strap and tighten nuts alternately to required torque (see the chart in Fig. 1).The vane must not rub the inside of the pipe or bind in any way. A CAUTION Do not trim the paddle.Failure to follow these instructions may prevent the device from operating and will void the warranty.Do not obstruct or otherwise prevent the trip stem of the flow switch from moving when water flows as this could damage the flow switch and prevent an alarm.If an alarm is not desired,a qualified technician should disable the alarm system. Fig.1Retard Adjustment O /�!%.; �� ANExTENDEDDNOTLEAVE FERroDCOVEROFF of Ttn,FOR E The delay can be adjusted by rotating the retard adjustment knob from 0 to the max setting(60-90 seconds).The time delay should be set at ' . t1 -� ,1,-• . the minimum required to prevent false alarms � I TIGHTEN NUTS S �\\.-b1,1 Ili ALTERNATELY -' CAUTION AJ1 -1e" 410 Hole must be drilled perpendicular to the pipe and vertically centered- - I` Refer to the Compatible Pipe/Installation Requirements chart for size. Correct Incorrect MOUNT ON PIPE SO ARROW ON SADDLE POINTS IN DIRECTION iL-ED d - -© c3 V 1,10,0- OF WATERFLOW u u illummillimimmilli 1 )011P Ills=1a1 / jowlngwa,e ROE IN ADAPTERADAPTER DIRECTION OF OF LL WATERFLPADDLIWATERFLOWr activatesOPPOSITE DIRECTION �'" 20mm±2m,MAX. II USE(2)5180162 ADAPTERS AS SHOWN ABOVE device in one direction only) DN50 ONLY 1 v/ DWG.1fI6-11 1/W661141.0 Compatible Pipe/Installation Requirements Model Nominal Pipe Nominal Pipe Pipe Wall Thickness Hole Size U-Bolt Nuts Size O.D. Lightwall Schedule 10(UL) Schedule 40(UL) BS-1387(LPC) DN(VDS) Torque inch mm inch mm inch mm inch mm inch mm inch mm inch mm inch mm ft-Ib n-m VSR-2 2 DN50 2.375 60.3 .065 1.651 0.109 2.77 0.154 3.91 0.142 3.6 0.091 2.3 1.25+.125/- VSR-2 1/2 2.5 - 2.875 73.0 .084 2.134 0.120 3.05 0.203 5.16 - - - - 33.0+2.0 .062 VSR-2 1/2 - DN65 3.000 76.1 - - - - - - 0.142 3.6 0.102 2.6 VSR-3 3 DN80 3.500 88.9 .083 2.108 0.120 3.05 0.216 5.49 0.157 4.0 0.114 2.9 VSR-3 1/2 3.5 - 4.000 101.6 - - 0.120 3.05 0.226 5.74 - - - - 20 27 VSR-4 4 DN100 4.500 114.3 .084 2.134 0.120 3.05 0.237 6.02 0.177 4.5 0.126 3.2 2.00±.125 50.8±2.0 VSR-5 5 - 5.563 141.3 - - 0.134 3.40 0.258 6.55 - - - - VVSR-6 6 DN150 6.625 168.3 .115 2.921 0.134 3.40 0.280 7.11 0.197 5.0 0.157 4.0 VSR-8 8 DN200 8.625 219.1 - - 0.148 3.76 0.322 8.18 0.248 6.3 0.177 4.5 NOTE:For copper or plastic pipe use Model VSR-CF. PRINTED IN USA MFG.#5401146-REV M PAGE 2 OF 4 11/15 VSR P PUTTER VANE TYPE WATERFLOW ® The Symbol of Protection ALARM SWITCH WITH RETARD Fig.2 Fig.3 Fig.4 Switch Terminal Connections Clamping To Iculove knockouts:Place screwdriver at Break out thin section of cover when Plate Terminal inside edge of knockouts,not in the center. wiring both switches from one conduit , entrance. •�� _ i 1 0_INCOfAllJG �r i. S 16a� � ,,��/ �" �" 0° DWG./1146-16 l �YX111> ,.._,_.,, ,..., , ► :-= �—4��� �r�����' ��015>1 An uninsulated section of a single conductor should not be looped �� \Ji j��il.I�'� around the terminal and serve as two separate connections. The � 1 wire must be severed,therebyprovidingsupervision of theI� P I connection in the event that the wire become dislodged from under NOTICE , 1-11.111-410111k �/` the terminal. Failure to sever the wire may render the device Do not drill into the base as this creates �.�O Dwi;.1146-13 inoperable risking severe property damage and loss of life. metal shavings which can create llilla° Do not strip wire beyond 3/8"of length or expose an uninsulated electrical hazards and damage the conductor beyond the edge of the terminal block.When using device.Drilling voids the warranty. stranded wire,capture all strands under the clamping plate. CONNECTOR Fig.5 Typical Electrical Connections NEUTRAL FROM BELL ::a; BREAKER NEUTRAL FROM BELL ' I3 ; . ,1 )BREAKER o .3:; Notes: LINE FROM BREAKER EOL(End Of Line Resistor) 1. The Model VSR has two switches,one can be used to operate a central station,proprietary or remote signaling unit,while the other contact Ii station, is used to operate a local audible or visual annunciator. 2. For supervised circuits,see"Switch Terminal Connections" (I+�'LI I III : I_�II drawing and warning note(Fig.4). ' ' NOTE: i When connecting to a UL Listed control panel,use the panes 4, '_' resistor value for circuit supervision. LV _ i* -= VSR P POTTER VANE TYPE WATERFLOW e The Symbol of Protection ALARM SWITCH WITH RETARD Maintenance Inspect detectors monthly. If leaks are found, replace the detector. The VSR waterflow switch should provide years of trouble-free service. The retard and switch assembly are easily field replaceable.In the unlikely event that either component does not perform properly,please order replacement retard switch assembly stock#1029030(see Fig.8).There is no maintenance required,only periodic testing and inspection. Retard/Switch Assembly Replacement(See Fig.8) NOTICE The Retard/Switch Assembly is field-replaceable without draining the system or removing the waterflow switch from the pipe 1. Make sure the fire alarm zone or circuit connected to the waterflow switch is bypassed or otherwise taken out of service. 2. Disconnect the power source for local bell(if applicable). 3. Identify and remove all wires from the waterflow switch. 4. Remove the(2)mounting screws holding retard/switch assembly to the base.Do not remove the(2)retard housing screws. 5. Remove the retard assembly by lifting it straight up over the tripstem. 6. Install the new retard assembly.Make sure the locating pins on the retard/switch assembly fit into the locating pin bosses on the base. 7. Re-install the(2)original mounting screws. 8. Reconnect all wires.Perform a flow test and place the system back in service. Fig.8 REMOVE(2)ORIGINAL MOUNTING SCREWS HOLDING RETARD/SWITCH ASSEMBLY TO BASE BREAKOUTTHIN SECTIONOF COVER 01 WHEN WIRING BOTH SWITCHES FROM ONE CONDUIT ENTRANCE. (2)ORIGINAL MOUNTING CREWS - RETARD/SWITCH ASSEMBLY ��� ram, Iiiiii 1'1 �.--_ ,,,,-.417 ilwol il„ IIP 1-,ioil /- .,, " (2)LOCATING PINS�At.'----'/ (2)LOCATING PIN I DO NOT REMOVE l BOSSES IN BASE\(2)RETARD HOUSING I •1 r i0 i Ii SCREWS 1..,1;•••"11.4 , II•j �� =.1'�..�... .. i��� . _ 'I1 II !I/I'�`i..�l0 w��'L7 BASE � =� I_ iiv,,1116_4ftiotc, or1, ,�,00111fr DWG#1146-10 Removal of Waterflow Switch • To prevent accidental water damage,all control valves should be shut tight and the system completely drained before waterflow detectors are removed or replaced. • Turn off electrical power to the detector,then disconnect wiring. • Loosen nuts and remove U-bolts. • Gently lift the saddle far enough to get your fingers under it. With your fingers,roll the vane so it will fit through the hole while continuing to lift the waterflow detector saddle. • Lift detector clear of pipe. PRINTED IN USA MFG.#5401146-REV M PAGE 4 OF 4 11/15 SYSTEM �..� SENSOR® SSM/SSV Series sY. rSENSOR Alarm Bells System Sensor's SSM and SSV series alarm bells are low current,high decibel notification appliances for use in fire and burglary systems or other signaling applications. Features Reliable Performance.The SSM and SSV series provide loud •Approved for indoor and outdoor use resonant tones.The SSM series operates on 24VDC and are motor driven,while the SSV series operates on 120VAC utilizing a vibrating •Low current draw mechanism. •High dB output •Available in six-inch,eight inch,and ten inch sizes Simplified Installation.For indoor use,the SSM and SSV series mount to a standard four-inch square electrical box.For outdoor •AC and DC models applications,weatherproof back box,model number WBB,is used. •DC models polarized for use with supervision circuitry •Mount directly to standard four-inch square electrical box indoors The SSM and SSV series come pre wired,to reduce installation time. The SSM series incorporates a polarized electrical design for use with •SSM and SSV series come pre-wired supervision circuitry. Agency Listings (ril) 41) 4:1; MEA LISTED APPROVED i._ approved AY 3005255 7135-16530217 331-01-F SSM/SSV Specifications Architectural/Engineering Specifications Model shall be a SSM or SSV Series alarm bell.Bells shall have underdome strikers and operating mechanisms.Gongs on said bells shall be no smaller than nominal 678710"(specify size)with an operating voltage of 24VDC or 120VAC(specify by part number).Bells shall be suitable for surface or semi-flush mounting.Outdoor surface mounted installations shall be weatherproof(using optional WBB weatherproof electrical box).Otherwise bells shall mount to a standard 4"square electrical box having a maximum projection of 21/2".Bells shall be located as shown on the drawings or as determined by the Authority Having Jurisdiction.Bells shall be listed for indoor/outdoor use by Underwriters Laboratories and the California State Fire Marshal,and approved by Factory Mutual and MEA. Physical/Operating Specifications Operating Temperature Range -31°F to 140°F Operating Voltage SSM series:24VDC SSV series:120 VAC Termination Provided with 2 sets of leads for in/out wiring Service Use Fire Alarm,General Signaling,Burglar Alarm Warranty 3 years Electrical Specifications Model Gong Diameter Nominal Voltage Operating Voltage Maximum Current Sound Output(dBA) (inches) Limit SSM24-6 6 Regulated 24VDC 16 to 33VDC DC-31.1 mA/FWR-53.5mA 82 SSM24-8 8 Regulated 24VDC 16 to 33VDC DC-31.1 mA/FWR-53.5mA 80 SSM24-10 10 Regulated 24VDC 16 to 33VDC DC-31.1 mA/FWR-53.5mA 81 SSV120-6 6 Regulated 120VAC 96 to 132VAC 53mA 85 5SV120-8 8 Regulated 120VAC 96 to 132VAC 53mA 82 SSV120-10 10 Regulated 120VAC 96 to 132VAC 53mA 82 *Sound output measured at Underwriter Laboratories,as specified in UL464 Ordering Information UL/FM Model No. ULC/Canadian Model No. Description SSM24-6 SSM24-6A Bell,6",24VDC,Polarized,82dBA SSM24-8 SSM24-8A Bell,8^;24VDC,Polarized,80dBA SSM24-10 SSM24-10A Bell,10-,24VDC,Polarized,81 dBA SSV120-6 SSV120-6A Bell,6",120VAC,85dBA SSV120-8 SSV120-8A Bell,8",120VAC,82dBA SSV120-10 SSV120-10A Bell,10",120VAC,82dBA WBB Weatherproof back box for SSM and SSV series,when installed outdoors SYSTEM ®2011 System Sensor. ����®Q� 3825 Ohio Avenue•St.Charles,IL 60174 Product specifications subject to change without notice Visit systemsensoccomfor /7 Phone:800-SENSOR2•Fax:630-377-6495 current product information,including the latestversion of this data sheet. A05-0260-010.08/11•#2870 Y o TOLCO www.tolco.com NIBCO Revision 12/18/2008 Fig. 200 - "Trimline" Adjustable Band Hanger ON LIMO Fig. 200R (Import) - "Trimline" Adjustable Band Hanger 41 ► w/Retainer Ring Size Range — 1/2" thru 8" pipe Material — Carbon Steel, Mil. Galvanized to G90 Ni--...- u specifications y Function — For fire sprinkler and other general piping - `v purposes. Knurled swivel nut design permits hanger '\ adjustment after installation. ® --- Features — r __ , • (1/2" thru 2") Flared edges ease installation for B /;2' '�, , B ;j' all pipe types and protect CPVC plastic pipe 7,% }; ,i 1 /,, 1,- %; from abrasion. Captured design keeps adjusting A I ;; nut from separating with hanger. Hanger is eas- �',„',, ' ily installed around pipe. ,:-----,--' A • 21/2" thru 8") Spring tension on nut holds it �\ _-_-"' ( P 9 securely in hanger before installation. Adjusting nut is easily removed. Fig.200 1"-2" Fig.200 21/2"-8" Approvals — Underwriters' Laboratories listed (1/2" thru 8") in the USA(UL) and Canada(cUL) 14•00-,, for steel and CPVC plastic pipe and Factory Mutual 'V Iwo Engineering Approved (3/4" thru 8"). Conforms to ,l , Federal Specifications WW-H-171 E, Type 10 and ® �`.� Manufacturers Standardization Society SP-69, Type �' - 10. B /' Maximum Temperature — 650°F j, ; B Finish — Mil. Galvanized. Stainless Steel materials will 1'� i i ' /ii' i' be supplied with (2) hex nuts in place of a knurl nub. ! /' %.. /;% Order By — Figure number and pipe size i Note — Figure 200R (import) with retainer ring and , ' non-captured knurl nut. _____-- Fig.200R 21/2"-8" Fig.200R 1/2"-2" Dimensions •Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Wt./100 1/2 3/8 8mm or 10mm 31/8 2% 400 11 3/4 3/8 8mm or 10mm 31/8 21/2 400 11 1 3/8 8mm or 10mm 33/8 25/8 400 12 11/4 3/8 8mm or 10mm 33/4 27/8 400 13 11/2 3/8 8mm or 10mm 3% 27/8 400 14 2 3/8 8mm or 10mm 41/2 3 400 15 21/2 3/8 10mm 55/8 41/8 600 27 - 3 3/8 10mm 57/8 4 600 29 - 31/2 3/8 10mm 73/8 51/4 600 34 4 3/8 10mm 73/8 5 1000 35 - 5 1/2 12mm 91/8 61/4 1250 66 6 1/2 12mm 101/8 63/4 1250 73 8 1/2 12mm 13% 83/4 1250 136 OFFICE/MANUFACTURING FACILITY•1375 SAMPSON AVE.•CORONA,CA 92879•PH: 951 737 5599•FAX: 951.737.0330 CUSTOMER SERVICE•800.786.5266 91 www.tolco.com ELCO Innovative Fastening Technologies 11 TM S H 1111 ININOMMINION 0001.1.1111.110i Threaded Rod Anchors Steel New Product featuring an exclusive • dual-directional head* Light-Gauge Steel * Patent-pending design -1? tkits --247ti • Wood From the makers of A 3t3)3#,..4°."4: HANGERMcite 4 ,t4.43 Threaded Rod Anchoring System Concrete ELCO High Performance in Threaded Rod Anchoring . The Next Generation of Engineered Anchors Elco developed their line of solid, one-piece, cold formed 6, HangerMate® anchors to speed installation of all threaded rod applications, including fire sprinkler, HVAC, refrigeration, general piping, and electrical systems. The entire HangerMate system - features the Power of One: it is engineered so only one driver ' - is needed for all anchor sizes (except HangerMate LG anchors), ........3. regardless regardless of the substrate material. :a - I U5P ENDER It's About Time: '-'Threaded Rod Anchors Saving Time = Saving Money Suspender threaded rod Features & Benefits anchors are the next step in -11 • Solid, one-piece, cold formed and the evolution of threaded rod , i I machined anchor anchoring. These one-piece i – Head won't spin off during installation anchors feature heads that are i`' • New head style: both end- and cross- both end-tapped and cross- i i drilled to accept vertical/in-line and tapped to permit both in-line ,. horizontal/side-mount . cross armed mountingand side-mounting ' .. applications and tapped_ of threaded rod systems, eye , – Decreases end drilled rings and more. .4, part numbers and taped ed �' required to I% Suspender anchors still ,� ''r / - feature the Power of One. complete a project �� v Select one driver–socket or sleeve–to drive all anchor – Accept 3/8-16 or 1/4-20 threaded components sizes (except Suspender LG • Entire system anchors). The Suspender �, drive sleeve eases switching requires only �������))��= between drillingand drivingin one driver �� r .� self-tapping self-drilling concrete applications. Just the 0.. 1 (except for threads point Suspender drive socket can Suspender LG for steel applications be used with the self-drilling 4 • anchors)I �������������� anchors for wood and steel, or • EZE270 ,,,,_ in pre-drilled applications. adapter allows twin-lead gimlet installation threads point This new system allows you to of 1/2-13 with slot consolidate your inventory •° ., threaded rod for wood applications to complete a project. It i i components . ))))).4)�)�))))))�. decreases downtime • Different —� twin-'lead ' gimlet required to retrieve the thread threads point correct part. Many styles are Factory Mutual (FM) approved or and point for concrete applications Underwriters Lab (UL) listed (see selection guide). styles available Speed installation of fire sprinkler, HVAC, refrigeration, general to meet the — — mm - piping, and electrical systems plus strut channels, cable trays, requirements of for light-gauge suspended ceiling grids, bridle rings and eye-rods: find out just specific application steel applications how versatile and beneficial the Suspender anchoring system materials can be. • LG style allows installation of threaded rod systems into light-gauge metals 2 F:/® .bUSpENDER Selection Guide Threaded Rod Anchors Listings and Approvals r; Vertical/Inline Mount Horizontal/Cross Mount For Elco] UL UL I FM FM UL UL FM FM Rod Steel CatalPipe Steel Pipe Steel Pipe Steel Pipe Steel Size Thickness No. Description Size Thick. Size Thick. Size Thick. Size Thick. Suspender'"Anchors for Steel Applications* 3•i)) ))i„))1O 1/4-20 X 1 #3 point 4" 12 ga. 4" 12 ga. 4" 12 ga. 4" 12 ga. 3/8-16 .060"-.210" EZD470-It 3$w)))r)m nrll 1/4-20 X 1 #3 point w/nuts 4" 16 ga. 4" 16 ga. 4" 16 ga. 4" 16 ga. 3 c)) ,))i»,lh ' 1/4-20 X 1-1/2#3 point 4" 12 ga. 4" 12 ga. 4" 12 ga. 4" 12 ga. 3/8-16 .060"-.210" EZD490-It 1 tp,%)r p.),�) 1 1/4-20 X 1-1/2#3 point w/nuts 4" 16 ga. 4" 16 ga. 4" 16 ga. 4" 16 ga. IU[I II i)),,k);Y)>� 1/4-20 X 1-1/2#5 point 4" 12 ga. 4" 12 ga. 4" 12 ga. 4" 12 ga. 3/8-16 .187"-.500" EZD510-It 1I I)))))5)m»,s l 1/4-20 X 1-1/2#5 point w/nuts 4" 16 ga. 4" 16 ga. 4" 16 ga. 4" 16 ga. Light-Gauge(LG)Steel t ) 1/4-20 26 ga.-.187" EZG610-I collapsing insert N/A N/A N/A N/A May only be used in vertical/inline mount j ) 3/8-16 26 ga.-.187" EZG620-I collapsing insert 4" 22 ga. 4" 22 ga. applications ?These products ship with nuts,for applications that require nuts to qualify for the UL Listing and/or FM Approval shown. Elco Listings and Approvals - Installs Catalog _ Vertical/Inline Mount Horizontal/Cross Mount Rod Size No. Description UL Pipe Size FM Pipe Size 1 UL Pipe Size FM Pipe Size • Suspender Anchors for Wood Applications c)" '-nA)h)))fl')),)r"r 3/8-16 EZD650-1 5/16 X 2-1/4 4" 4" 4" Suspender Anchors for Concrete Applications �},h)))illn)))))'h),- 3/8-16 EZD730-I 5/16 X 2-1/4 4" 4" Suspender MP(Multi-Purpose)Anchors for Steel,Wood or Concrete Applications )10 In)1D1)11b)1OD)ATO 3/8-16 EZD930-I 1/4-10X2 NA NA NA NA NOTE: It is the responsibility of the installer to determine the application-specific details under which a code approval or listing was granted. Contact Elco Construction Products for more information. NOTE: 1/4" Rod Adapter EZE270-I on following page. Installation Tools Elco Elco Cat.No. Description Cat.No. Description Steel and Wood Applications Light-Gauge Steel Applications 0 ) — EZE415 Drive Socket EZE320 25/64 Drill Bit with Stop Collar Concrete Applications 0 EZE420 Drive Sleeve 1 f EZE290 Manual Tool EZE240 Drill Bit Adapter ANSI 1/4" Tanged Drill Bit 19/32 Drill Bit EZE340 for Hammer Drills EZE330 with Stop Collar —c°,113EZE350 ANSI 1/4" SDS Drill Bit for Rotary Hammer DrillsEZE490 Manual Tool 1 3 a HANGERlate Selection Guide Threaded Rod Anchoring System HangerMate®Anchors for Steel Applications Rod Steel Elco UL Pipe UL Steel FM Pipe FM Steel Size Thickness Cat.No. Description Size Thickness Size Thickness OM }}} 1/4-20 .060-.250 EZG160-I 1/4-20X1 #3 point N/A N/A N/A N/A 1 }}24 3/8-16 .060-.250 EZG471-I 1/4-20X1 #3 point w/nuts 4" 0.060" 4" 16 ga. 51 D))}'))1}9)}})}}) + 3/8-16 .060-.250 EZG530-I 1/4-20X2#3 point 4" 0.125" _ HangerMate Anchors for Wood Applications Rod Size Elco Cat.No. Description UL Pipe Size FM Pipe Size fn M}iM)})A)y;;;:: 1/4-20 EZG315-I 5/16X2-1/4 NA NA *11,4)1M111)),-- 3/8-16 EZG650-I 5/16X2-1/4 4" 4" ((I[1 1163i )')igiNW" 3/8-16 EZG670-I 5/16X3 4" 4" HangerMate Anchors for Concrete Applications R1 0)a)))))ij}))1))» 1/4-20 EZG365-I 5/16X2-1/4 NA NA ((f[/ IN)+i7)1)1)a?)lt. 3/8-16 EZG730-I 5/16X2-1/4 4" NOTE:It is the responsibility of the installer to determine the application-specific details under which a code approval or listing was granted. Contact Elco Construction Products for more information. Installation Tools Elco Cat. Elco Cat. No. Description No. Description EZE215 Drive Socket w— EZE340 ANSI 1/4" Tanged Drill Bit for Hammer Drills 0 EZE220 Drive Sleeve ANSI 1/4" SDS EZE350 Drill Bit for Rotary Hammer Drills EZE240 Drill Bit Adapter 7/32"Tanged Drill Bit for EZE360 Hammer Drills 25/64 Drill Bit =3=1° EZE320 with Stop Collar so:---. , - - EZE380 7/32" SDS Drill Bit for Rotary Hammer Drills 1/2" Threaded Rod Adapter for Both Suspender"' and HangerMate® Anchors All Materials T Listings and Approvals Rod Elco Cat. Vertical/Inline Mount Size No. Description UL Pipe Size FM Pipe Size 1/2-13 Internally-threaded anchor with (({lit 1/2-13 EZE270-I 3/8-16 external thread NA NA (fits Suspender and HangerMate anchors for 3/8-16 rod) Power of One Select one tool - sleeve or socket -to install all Suspender anchors* *Except for Suspender LG Anchors EZD610-1 and EZD620-I. , .;For concrete, a standard 1/4" drill bit can be used with the drive sleeve. h:r® Performance Data for Suspender'' and HangerMate® Anchors Threaded HANGERMate. Threaded Rod Anchors Threaded Rod Anchoring System Average Ultimate Value (lbs)* Average Ultimate Value (lbs)* Steel Applications _ Steel Applications Rod Anchor Steel Thickness Cat. Rod Anchor Steel Thickness Cat.No. Size Shank 062" .074" .104" .125" .1875" .250" No. Size Shank .062" :074" .104" .125" .1875 .250" - EZD470-I 3/8-16 1/4-20 786 1139 1738 2376 4694 NA EZG160-1 1/4-20 1/4-20 786 1139 1738 2376 4694 5994 EZD470-I 3/8-16 1/4-20 3435 4024 4279 4692 5812 NA EZG471-I 3/8-16 1/4-20 3435 4024 4279 4692 5812 5909 _ with nuts EZD490-I 3/8-16 1/4-20 786 1139 1738 2376 4694 NA EZG530-13/816 1/4-20 786 1139 1738 2376 4694 5994 EZD490 I 3/8-16 1/4-20 3435 4024 4279 4692 5812 NA with nuts Wood Applications EZD510-I 3/8-16 1/4-20 N/A N/A N/A N/A 3677 5207 Rod Anchor Douglas Southern EZD510-I Cat# Size Shank Fir Pine Hemfir with nuts 3/8-16 1/4-20 3435 4024 4279 4692 5812 5909 EZG315-I 1/4-20 5/16-14 2487 2162 1768 Light-gage Steel Applications EZG650-I 3/8-16 5/16-14 2487 2162 1768 Cat. Rod Gage EZG670-I 3/8-16 5/16-14 2487 2162 1768 No. Size 26 22 20 18 16 EZG610-I 1/4-20 848 1025 1153 1410 1880 Concrete Applications EZG620-I 3/8-16 - 1500 1500 1500 1880 Cat# Rod Size Anchor Shank 3650 PSI Concrete Wood Applications EZG365-I 1/4-20 5/16-14 2188 Cat. Rod Anchor Douglas Southern EZG730-I 3/816 5/16-14 2188 No. Size. Shank Fir Pine Hem-fir EZD650-I 3/8-16 5/16-14 2487 2162 1768 *Performance Testing Notes(both Suspender and - Concrete Applications HangerMate Anchors): 3650 PSI Concrete 1.The loads indicated are average ultimate values achieved Rod Anchor Vertical/In-Line Horizontal/Cross under laboratory conditions and appropriate safety factors Cat.No. Size Shank Applications Applications should be applied for design purposes. EZD730-I 3/8- 16 5/16-14 2188 2767 2. NFPA(National Fire Protection Assoc.)minimum fastening requirements are five times the weight of a 15-foot section of Suspender MP(Multi-Purpose)Anchors water filled pipe plus 250 lbs. This is 1475 lbs.for 4" pipe. Material Value Material Value 3.All test values were obtained using 3/8-16 rod. When 1/4-20 Southern Pine 541 12 ga.Steel 1754 rod is used,the strength of the rod may be less than the 16 ga.Steel 880 1/8" Steel 2505 pull-out values of the anchors. 14 ga.Steel 1106 Concrete(3300 PSI) 2933 Sample Applications Attach Loop, Clamp Ring and Clevis Hangers Mount Struts and Tracking Systems for and Shoes to Hang Piping for Sprinkler, General Electrical Systems, Ceiling Grids and More Plumbing and Other Systems • --N. liip , i , ,__ 4 i® . J 1. „4" rill. . ., . „,..,..." /iw 1 . \ _ .., �__. I Hang Cable Trays . III di D L_ ELCO Threaded Rod Hanger Cross Reference Steel Applications U5pENDER Threaded Rod Anchors Original Hangermate® Part Description Rod Size Vertical/Horizontal Part No. Part Not ITW Sammys®Part No. EZG450 DST10 EZG470 DSTR1 • 1/4-20 x 1 EZG471 DSTR516 3/8-16 rod Both EZD470 I No.3 point w/nuts EZH455 SWD10 EZH475 SWD15 EZH476 SWDR1 EZG490 DST15 1/4-20 x 1-1/2 EZG491 SWD15 3/8-16 rod Both EZD490 I No.3 point w/nuts EZH495 DST516 EZH496 SWDR516 EZG510 TEK50 1/4-20 x 1-1/2 EZG511 DSTR1 1/2 3/8-16 rod Both EZD510 I No.5 point w/nuts EZH515 SWT15 EZH516 SWDR1-1/2 1/4-20 x 1 No.3 point 1/4-20 rod Vertical EZG160-I - DSTR100 1/4-20 x 1 3/8-16 rod Vertical EZG471-1 - DSTR516 No.3 point w/nuts 1/4-20 x 2 No.3 point 3/8-16 rod Vertical EZG530-I - DST20 Wood Applications Part Description Rod Size Vertical/Horizontal Suspender Part No. Original Hangermate®Part No.t ITW Sammys Part No. GST10 • GST20 5/16 x 2-1/4 3/8-16 rod Both EZD650-I EZG650 GST25-380 EZH665 SWG10 ` SWG20 SWG25-380 5/16 x 2-1/4 1/4-20 rod Vertical EZG315-I - GST200 GST10 5/16 x 2-1/4 3/8-16 rod Vertical EZG650-I - G5T20 GST25-380 5/16 x 3 3/8-16 rod Vertical EZG670-I - GST30 Concrete Applications Part Description Rod Size Vertical/Horizontal Suspender Part No. Original Hangermate®Part No? ITW Sammys Part No. 5/16 x 2-1/4 3/8-16 rod Both EZD730-I EZG730 CST20 EZH735 SWC20 5/16 x 2-1/4 1/4-20 rod Vertical EZG365-I - CST200 5/16 x 2-1/4 3/8-16 rod Vertical EZG730-I - CST20 Specialty Applications Part Description Rod Size Vertical/Horizontal Suspender Part No. Original Hangermate®Part Not ITW Sammys Part No. 1/4-10 x 2 3/8-16 rod Both EZD930-I - - No.2 point 1/4-20 Insert 1/4-20 rod Both EZG610 - XP200 EZG580 XP20 3/8-16 Insert 3/8-16 rod Both EZG620 EZG590 XP35 EZG600 GST2 GST3 EZE270 (NOTE: Must be used DST2.0 1/2"Adapter 1/2-13 rod Both in conjunction with - DSTR1.0 any Suspender or DSTR5.16 • HangerMate 3/8 rod DST5.16 hanger) TEK5.0 CST2 6 t Some of these numbers refer to Hangermate anchors that are no longer manufactured. ® UspENDER Installation Instructions Threaded Rod Anchors Steel or Wood Applications . Concrete/Masonry Applications Suspender anchors drill their own _ For SDS-drive drills, use Elco drill holes in metal and wood applications, `� bit EZE350; for keyed chuck-type so pre-drilling is unnecessary. Insert drills, use Elco tanged bit EZE340 the Suspender EZE415 (HangerMate installed in adapter EZE240. Drill at , EZE215) drive socket in your drive tool, least 2-1/2" into the concrete. . then place the anchor in the socket. ` Slide concrete drive sleeve EZE420 Simply position the self-drilling point *_ (HangerMate EZE220) over bit `" of the anchor at the intended point i and onto hex. Insert anchor into ;0(HangerMate of installation, and drive the anchor. socket and install. Drive until the The hex drive will automatically SafetySet feature seats the anchor — disengage when anchor is seated. AI' and disengages. "". Parts can also be installed in Light-Gage Steel Applications concrete using a standard 1/4" For EZG610-I anchor use EZE320 or masonry bit to drill the hole and MEI other 25/64" drill bit to drill a hole using the Suspender EZE415 ' in the metal. For EZG620-I anchor use EZ330 or other 19/32" drill bit threaded shaft (HangerMate EZE215) drive socket d1N. sleeve to set the anchor. Al to drill hole in the metal. 111 larger Use the proper manual tool shaft (EZE290 tool for EZG610-I anchors; Aki The EZE220 Suspender k EZE490 tool for EZG620-I anchors). ;1 drive sleeve drill bits are " *; slips over drill Thread anchor onto threaded shaft ' engineered " p • of tool. Rotate shaft clockwise until '" for accurate bits to ease "� � - ,',- installation drilling in head of anchor hits tool sleeve. , concrete "'-. of Suspender Insert anchor fullyinto drilled 1 applications. � � anchors in concrete. hole. Turn shaft clockwise until '...,ti� _ firm resistance is felt. Turn shaft` counterclockwise to break threads Installation of EZE270-1 Adapter of tool loose from insert. Thread J For 1/2-13 Threaded Rod rod or component into Simply install any 3/8" HangerMate Suspender anchor. anchor as required, then thread the -\--i--i71'� EZE270-I adapter into it. o 1 Suspender LG tools speed installation of LG anchors into .. ' NOTE: Use of adapter does not light-gage steel increase performance value of 3/8" Suspender anchor. Check corresponding 3/8" anchor specifications for load-carrying capacity and add appropriate safety factor. NOTES:As with all cutting tools and fasteners, normal safety precautions should be observed to avoid electrical installations, other utilities and reinforcement bars. Careful use will provide the utmost safety and reliability.The wearing of safety glasses by users and persons in the vicinity is required by Federal Law. Shoulders of installed Suspender anchors must be flush to the metal, masonry or wood substrate materials. Suspender anchors should not be subjected to vibratory or shock loads resulting from such applications as anchorings for reciprocating machinery, crane rails or hoists. Care should be taken to not damage Suspender anchors or the substrate into which they are installed when loading pipe, installing cable tray, or otherwise suspending components from Suspender anchors. Failure to do so may result in significant loss of holding power. Complete Suspender product information and technical application assistance is available from Elco Construction Products at 1.800.435.7213 7 ;s1bUS ENDER Threaded Rod Anchors Product and Warranty Information Fasteners must be used only in compliance with applicable building codes and as approved by authorities having jurisdiction. - To reduce the risk of installation failure resulting in injury or property damage, follow all safety - and installation instructions. Follow all installation tool safety instructions. • Code listings and approvals require that Suspender anchors be installed with Suspender drive sockets. Shoulders of installed Suspender anchors must be flush to the metal, masonry or wood substrate materials. Suspender anchors should not be subjected to vibratory or shock loads resulting from applications such as anchorings for reciprocating machinery, crane rails or hoists. Care should be taken to not damage Suspender anchors or the substrate into which they are installed when loading pipe, installing cable tray, or otherwise suspending components from Suspender anchors. Failure to do so may result in significant loss of holding power. As with the use of all cutting tools and fasteners, normal safety precautions should be observed to avoid electrical installations, other utilities and reinforcement bars. This literature was prepared as an introductory summary of the Suspender threaded rod anchoring system from Elco Construction Products and is not, therefore, intended to describe _ all hazards, limitations, warnings, precautions, etc. pertaining to the use of the product. The information and data presented herein are believed to be accurate and reliable, however, due to the wide variety of possible intervening factors, the suitability of the product for the use intended is the sole responsibility of the user. Specifications and other information contained herein supersede all previously published material and are subject to change without notice. For complete and up-to-date code listings and approvals, safety and installation instructions, and other information, see. www.elcoconstruction.com. All Suspender anchors are warranted to be manufactured free from defects in material and workmanship. Under this warranty, Elco Construction Products will provide, at no charge, replacement product for any Suspender anchors proven to be defective when installed in accordance with our published recommendations and in applications considered by us as suitable for this product. This warranty is in lieu of any and all warranties, expressed or implied, and in no case will Elco Construction Products be liable for incidental, liquidated or consequential damages. For applications assistance or more information, please contact: B_CO Elco Construction Products ® 701 E. Joppa Road • Towson MD 21286 Phone: 800-435-7213 (USA & Canada) - Fax: 563-387-3540 www.elcoconstruction.com Elco®,HangerMate®and Suspender"are trademarks of Elco Construction Products. Sammys®is a registered trademark of ITW Buildex and Illinois Tool Works,Inc. 8 02015 Elco Construction Products•Rev.4/15 Seismic Bracing Fig. 980 - Universal Swivel Sway Brace Attachment - 3/8" to 3/4" ®TOLCO Size Range: One size fits bracing pipe 1"(25mm)thru 2"(50mm), B-Line APPROVED 12 gauge(2.6mm)channel, and all structural steel up to 1/4"(31.7mm)thick. Material: Steel viao Function: Multi-functional attachment to structure or braced pipe fitting. i Features: This product's design incorporates a concentric attachment opening which is critical to the performance of structural seismic connections. ..<„.,, p NFPA 13 indicates clearly that fastener table load values are based only on \\t--\ • concentric loading. Mounts to any surface angle. Break off bolt head assures verification of proper installation. A Installation: Fig.980 is the structural or transitional attachment component / B of a longitudinal or lateral sway brace assembly. It is intended to be combined with the"bracing pipe"and TOLCO"braced pipe"attachment, Fig. 1000, 1001, Set Bolt 4L, or other TOLCO approved attachment to pipe to form a complete bracing Included assembly. NFPA 13 guidelines should be followed. Mounting Hardware Is Not Included To Install: Place the Fig. 980 onto the"bracing pipe".Tighten the set bolt until the head breaks off.Attachment can pivot for adjustment to proper brace angle. Approvals:—Approved by Factory Mutual Engineering(FM). For UL Listed information refer to page 66. Note: Fig. 980 Swivel Attachment and Fig. 1000, 1001,4L or other TOLCO approved attachment to pipe that make up a sway brace system of UL Listed attachments and bracing materials which satisfies the requirements of Underwriters Laboratories and the National Fire Protection Association(NFPA) ,r,y, Finish: Plain, Electro-Galvanized or Stainless Steel. Contact B-Line for _ alternative finishes. - Order By: Figure number and finish. Fig.980 �' 4Fr Pat.#6,273,372,Pat.#6,517,030,Pat.#6,953,174, 40,iiiev- Pat.#6,708,930,Pat.#7,191,987,Pat.#7,441,730, /'.. Pat.#7,669,806 / Designed to meet or exceed requirements of FM DS 2-8. Fig.4L ,, J*, Lateral Brace8. Longitudinal :, Brace Part Mtg.Hdw. Mounting Hole Max.Design Load**(FM) Approx. Number Size A B D 30°-44° 45°-59° 60°-74° 75°-90° Wt./100 in. (mm) in. (mm) in. (mm) in. (mm) lbs./(kN) lbs./(kN) lbs./(kN) lbs./(kN) ' lbs. (kg) 980-3/8 3/8" (9.51 51/4"(133.3) 17/8" (47.6) 13/32"(10.3) 149 (67.61 980-1/2* 1/2"(12.7) 51/4"(133.3) 17/8" (47.6) 17/32" (13.5) 1320 1970 2310 2550 148 (67.1) 980-5/8 5/8"(15.9) 51/4"(133.3) 17/8" (47.6) 11/16"117.5) 15.87) (8.76) (10.27) (11.34) 147 (66.7) 980-3/4 3/4"(19.0) 51/4"(133.3) 17/8" (47.6) 13/16" (20.5) 146 (66.2) * Standard size. ** Installed with 1" or 11/4" Schedule 40 brace pipe. FM Approved design loads are based on ASD design method. Eaton's B-Line Business seismic bracing components are designed to be compatible only with other B-Line bracing components, resulting in a listed seismic bracing assembly. B-Line's warranty for seismic bracing components will be the warranty provided in B-Line's standard terms and conditions of sale made available by B-Line,except that, in addition to the other exclusions from B-Line's warranty, Eaton's B-line Business makes no warranty relating to B-Line's seismic bracing components that are combined with products not provided by Eaton's B-Line Business. All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line Protection Solutions -Line 67 b7'\/ :NV Seismic Bracing Fig. 1001 - Sway Brace Attachment (i)TOLCO- Size Range: Pipe size to be braced: 1"(25mm)thru 8"(200mm) IPS. 4:0* Pipe size used for bracing: 1"(25mm)and 11/4"(32mm)Schedule 40 IPS. APPROVED Material: Steel Function: For bracing pipe against sway and seismic disturbance. The pipe attachment component of a sway brace system: Fig. 1001 is used in conjunction with a Fig. 900 Series fitting and joined together with bracing pipe per NFPA 13,forming a complete sway brace assembly. *It! Features: Can be used to brace schedules 7 through 40 IPS. Field adjustable, making critical pre-engineering of bracing pipe length unnecessary. Unique design requires no threading of bracing pipe. Can be used as a component of a four-way riser brace. Bolts Comes assembled and ready for installation. Fig. 1001 has built-in Included visual verification of correct installation. See installation note below. l 1 Installation Note: Position Fig. 1001 over the pipe to be braced and tighten two hex head cone point set bolts until heads bottom out.A minimum of 1"(25mm)pipe extension is recommended. Brace pipe can be installed on top or bottom of pipe to be braced. Approvals: Approved by Factory Mutual Engineering(FM). For UL Listed information refer to page 70. Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and materials. Order By: Order by figure number, pipe size to be braced,followed by pipe "" size used for bracing(1"(25mm)or 11/4 (32mm)) , and finish. Important Note: Fig. 1001 is precision manufactured to perform its function as a critical component of a complete bracing assembly.To ensure performance,the FM Approval requires that Fig. 1001 must be used only with other TOLCO bracing products. Designed to meet or exceed requirements of FM DS 2-8. Design load-For Sch.7,Sch.10,&Sch.40 Pipe Pipe Part Number&Approx.Wt./100 Allowable Horizontal Capacity(Ibf)Per Installation 1,43 Size 1"(24mm)Brace Pipe 11/4"(32mm)Brace Pipe 30°-44° 45°-59° 600-74° 750-90° in. (mm) Lbs. (kg) Lbs. (kg) Lbs. (kN) Lbs. (kN) Lbs. (kN) Lbs. (kN) 1" (25) 1001-1 X 1 100.0 (45.3) 1001-1 X 11/4 118.0 (53.5) 1800 (8.00) 2550 (11.34) 3120 (13.88) 3490 (25.52) 11/4"(32) 1001-11/4 X 1 100.0 (45.3) 1001-11/4 X 11/4 114.0 (51.7) 1230 (5.47) 1740 (7.74) 2140 (9.52) 2380 110.58) 11/2"(40) 1001-11/2 X 1 100.0 (45.3) 1001-11/2 X 11/4 115.0 152.1) 1230 (5.47) 1740 (7.74) 2140 19.52) 2380 (10.58) 2" (50) 1001-2 X 1 108.0 (49.0) 1001-2 X 11/4 121,0 (54.9) 1230 (5.47) 1740 (7.74) 2140 (9.52) 2380 (10.581 21/2"(65) 1001-21/2 X 1 138.6 (62.8) 1001-21/2 X 11/4 160.4 (72.7) 800 (3.56) 1130 (5.02) 1380 16.14) 1540 (6.85) 3" (80) 1001-3 X 1 147.2 (66.7) 1001-3 X 11/4 168.7 (76,5) 850 (3.78) 1200 (5.34) 1470 (6.54) 1640 (7.29) 4" (100) 1001-4 X 1 160.9 (73.01 1001-4 X 11/4 182.4 (82.7) 850 (3.78) 1200 (5.34) 1470 (6.54) 1640 (7.29) 6" (150) 1001-6 X 1 190.0 (86.2) 1001-6 X 11/4 211.4 (95.9) 510 (2.27) 730 (3.25) 890 (3.96) 990 (4.40) 8" (200) 1001-8 X 1 217.4 (98.6) 1001-8 X 11/4 238.8 (108.3) 510 (2.27) 730 13.25) 890 (3.961 990 (4.40) 1 FM Approved when used with 1 or 11/4 inch NPS Schedule 40 GB/T 3091,EN 10255H,or JIS G3451 steel pipe as the brace member. 2 Load rating for LW above refers to FM Approved Lightwall Pipe commonly referred to as"Schedule 7".These ratings may also be applied when EN 10220 and GB/T 8163 steel pipe. 3 Load rating for Schedule 10 above may be applied to GB/T 3092,EN 10255M and H,or JIS G3454,FM Approved Thinwall, or Schedule 40 steel pipes. Note: See UL load ratings in UL Listed Design Load chart shown under drawing. \-e0 *Li n a - t$, 01 All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line Fire Protection Solutions 71 by F.1 N Bulletin 205Rev.AC ou N. Installation and Service ry o Wrenches CD C D ) Sprinkler Wrenches: Model ZX Pendent For Models: ' Model G4 • ZX-1 QR,ZX QR INST,ZX SR INST, ', ZX-RES&ZX-RES/2 For Models: • XL QR,XL INST OR EC • G4,G4FR, G4QR, F4FR, F4FR-NF i &F4/RES Concealed -gemsti _ • RFC 56 Concealed Model XLO EC For Model: Model GFR2 • G4 XLO QREC/EC For Models: Concealed Sprinkler • F1, F1/EC, F1 FR, F1 FR/EC& F1/RES/F2 Recessed PendentRellab_ 111:16 • G/F2&GFR Recessed • F1/RES/F2&G/F1/EC4 Model XLO Recessed Horizontal Sidewall liar • G/F1,F1/EC6&F1FR/EC8&9 s • GFR VELD ` Recessed Horizontal Sidewall Recessed Pendent4. • F1&F1 FR Intermediate Level Pendent Similar to Model GFR1 Wrench • Model FP Push-On Recessed except for larger wrench opening WI Escutcheon for Fl and Fl FR Model XLO. I • Horizontal Sidewall • Model FP Push-On Recessed ".. - Escutcheon for Fl and Fl FR • Pendents Model XL02 • DH-80 Recessed • DH56 Dry Sprinkler • DH56 Recessed, DH56 Concealed • GFR VELO Pendent ~„ and all Models that use GFR1 • &Recessed Pendent • F156 and F1FR56 Recessed Pendent • Fl Res 76 Recessed&CCP Pendent For sprinklers with bulb protectors, the clasp of the bulb For sprinklers with bulb protectors, the clasp of the bulb protector must be facing out of the wrench as shown. protector must be facing out of the wrench as shown. Model ZX Horizontal Sidewall Model RC1 9 �[' For Models: L.; For Models: • ZX-1 QR,ZX-RES,ZX QR INST,ZX • G, G/F1 Recessed Pendent SR INST&ZX INST QREC • G1 &F1/RES Concealed r • XL QR,XL INST QREC • G Intermediate Level Pendent • F1FR&F1FR QREC ConcealedModel FC u:1 Flat Concealed For Model: .e.; Model G3R/C • RFC 43 For Models: `�#�;� • RFC 49 [Lfild • F3/F3QR Recessed&Concealed Dry - Pendent „. i • F3/F3QR Recessed Dry Horizontal Sidewall A 1/2"square drive allows all the proceeding wrenches to be For sprinklers with bulb protectors, the clasp of the bulb driven by the extension and ratchet used with the Model FC protector must be facing out of the wrench. Sprinkler Wrench. These wrenches must be used with the sprinklers indicated to minimize the possibility of damaging the sprinkler. The cavity of these wrenches provides sufficient support to the sprinkler to assure a safe, positive installation. The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York, 10523 Model D Model N For Models: - For Model f • F1,F1 FR,Fl RES,G&GFR " * -,' :, :-11►' • N252 ,,,. Pendent, Upright&HSW • F1,F1 FR&G VSW This wrench is used for both recessed i and non-recessed sprinklers. The "just right" length of these wrenches provides the proper Model J1 leverage when tightening sprinklers into pipe For Models: fittings—preventing sprinkler damage. The slotted opening . J 168 Upright .,. prevents wrench slippage which could damage the sprinkler. Painted grey. • J 112 ECOH Pendent&Upright • JL 112 ECOH Pendent&Upright Model H Model RJ For Models: For Models: � • J112 Recessed Pendent • H&HL(ESFR) • JL112 Recessed Pendent • G XLO Upright • G&GFR VELO Pendent Model FEA Escutcheon Similar to Model D,except for wrench opening. Wrench Painted blue. For: • Threaded Recessed Sprinkler Model G3 Escutcheons * "` ' This wrench is welded wire, cylindrical in n For Models: configuration.The closed end is held in the 1 • F3/F3QR Dry Pendent&HSW 7.7,7,- , palm of the hand.The open end fits over the This wrench is similar to the Model sprinkler and has two prongs to engage, ;.. :I D wrench except the wrench corresponding holes in the escutcheon opening is keyed and larger. flange to provide a positive means of Painted red. tightening the escutcheon without leaving • DH56 Dry EC HSW any hand smudge marks on the ceiling. Diameter: 23/". . . Height:2" Valve Wrenches: Model E Alarm Valve Seat Model A & D Dry Pipe Valve Seat Model B & BX - Model C1 & C2 Lever Bracket Nut Deluge Valve Seat Made of cast iron.These wrenches are specially designed to be Model LDX Dry Pipe Valve used with Reliable Models A, Cl, C2 and D Dry Pipe Valves. Seat When used with C series valves,the lugs on the wrench engage the slots of the Lever Bracket Nut. Removal of this nut permits Made of cast iron. Specially designed for lifting out the entire clapper assembly.When used with Reliable easily removing and replacing the valve seat without damaging it.Has spaced slots r1.4 Models A and D Dry Pipe Valves, the lugs engage ribs in the for engaging seat lugs and a 1"or 1'/z"hex '`` bronze seat and enable it to be unscrewed. boss for gripping with a standard open end, The 11/2"hex boss on the top of the wrench allows it to be used socket or adjustable wrench. Typical with a standard open end, socket or adjustable wrench. Valve Seat Available in 4"and 6"sizes.The 4"size also fits the Model A 21/2" Dry Pipe Valve. Sizes Fit Models E Alarm Valves, .kyr .. B&BX Deluge&LDX Dry Pipe Valves Wrench Model Models Hex Y.. Size E B,BX&LDX Boss 21/2" 6881230000 — 1" „. i .440, 11. _z 3” 6881230000 — 1" 1 4" 6881240000 6881240000 1X 4— 6" 6881260000 6881506000 1}i Model D Seat Lever Bracket Nut 8" 6881280000 — 1}i The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years,and are installed and serviced by the most highly qualified and - reputable sprinkler contractors located throughout the United States,Canada and foreign countries. - Manufactured by The Reliable Automatic Sprinkler Co.,Inc. Iemiab'a (800)431-1588 Sales Offices RecycledPaper (800)848-6051 Sales Fax (914)829-2042 Corporate Offices Revision lines indicate updated or new data. 11111111111111.1111.111111111111111111.11111111111111.11111111.1. www.reliablesprinkler.com Internet Address E.G.Printed in U.S.A.6/07 P/N 9999970036