Plans (84) • AquaSAFETM' GENERAL NOTES: Senju RC-RES:Open Web Truss/TJI Construction Insulation Recommendations See General Notes 8.2.5.7 for Architectural In areas subject to freezing,care should be taken in unheated attic spaces `v ProPEX LF Brass Fire to cover Uponor AquaPEX tubing completely with insulation. Insulation Feature Requirements '�. '" Sprinkler AdapterTee - should nt"U the guidelines of the insulation manufacturer. See Uponor I`„ a 1. THIS SYSTEM IS DESIGNED AS PER NFPA 13D 2016 EDITION AS A RESIDENTIAL MULTIPURPOSE SYSTEM a_, Blakin Ma be Fire Sprinkler Adapter Document"U %ME ��•• x SECTION 3.3.11.3. -�, g y "Uponor AquaSAFE Attic Insulation Guklrines"for attic .:6 .---% 7. 4-. Required.If Push-on Nut installation guidelines(Provided in Contractors Documents package or online / O i � Blockingis Used, 1 t/4"Min. at www.Uponorpro.com). J a- 2. UPONOR COMPANY RESERVES THE EXCLUSIVE RIGHTS TO ALL DETAILS AND DRAWINGS AS SHOWN ON B;1-,,, I '� qtr „ C n THIS SHEET. THESE DETAILS AND DRAWINGS ARE PROPRIETARY INFORMATION OF UPONOR COMPANY AND Use The 2 Top 1 "Max. UNAUTHORIZED USE MAY BE SUBJECT TO PROSECUTION TO THE FULL EXTENT OF THE LAW. Screw Holes. f L J < I-i amt.,of Mounting Extreme Temperature Installations Planter Box Window,Bay Window or Similar Feature. C Cud l/ Bracket to Face of True If no additinal floor area is created No Additional Sprinkler is Required. SEP P 1 6 2019 O 1 g -----�_ Aq Residential Fire Safety systems are often installed in attics or C a°o 3. THE DESIGN OF THIS SYSTEM IS DICTATED BY SPECIFIC CEILING HEIGHTS AND ROOM SIZES. IT IS THE [I [) I Fire Sprinkler Adapter other areas exposed to temperature extremes of heat and/or cold. Follow 8'-0"or less �z:4! 1 RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO ENSURE THAT THE CONDITIONS SHOWN ON THESE MountingBracketII,, PLANS ARE EXACTLY AS THEY EXIST IN THE FIELD. DEVIATIONS FROM THE DESIGN MAY CAUSE THE •_-� the recommended extreme weather installation instructions to isolate and / �f N$o SYSTEM TO BE UNABLE TO CONTROL A FIRE,IF THE BUILDING CONSTRUCTION DIFFERS FROM THE FIRE t € t - }- [r',. protect system components from extreme temperatures. Because this F,.:RES-1F I �,¢� M u SPRINKLER PLAN,CONTACT THE SYSTEM DESIGNER IMMEDIATELY. ,r l Y (' I e e `� v.,- system also delivers domestic cold water directly to plumbing fixtures, ® t Tr I 3-810 u 1 1/Z" 9'-0'or less ) 4 > _il113 F ° l:LAt T 4". ' i\•'' F i i1,° Full Course ''�' Uponor highly recommends that you protect the tubing with adequate / ' ;.T.,,,,,.. m N t 4. THIS SV6i EM AND THE ACCOMPANYING HYDRAULIC CALCULATIONS ARE DESIGNED IN COMPLIANCE WITH ..a s.., t- 1. F t ,,I 173 i.,-,a N Insulation in warm weather areas to minimize heating of the cold water w z Thread mrHol L> �L_li UN ° o NFPA 13D 2016 EDITION. In Bottom Holes supply. i,11 c9 u 5. "STAND-ALONE"OR"MULTIPURPOSE,WET PIPE"SYSTEMS ARE NOT PERMITTED TO USE ANTI-FREEZE. - m in ry°a n/ Installation methods include,but are not limited to: i e i,� \ C N F 6. MODIFICATIONS ARE PROHIBITED.SPRINKLERS THAT HAVE BEEN PAINTED,CAULKED,MODIFIED OR Lead-Free Flat o- • Tenting over the fire sprinkler piping. DAMAGED MUST BE REPLACED. Concealed Sen]u r Ts " -� • Additional layers of belt insulation. If additional floor area is created.Cannot exceed 18 ft°,be more than 2'-0" "".9 Concealed Flat • Increased depth of blown-in insulation. deep,more than 9'-0"wide and be with in the coverage area of the P, < •. LLou < Sprinkler Head Cover Plate • sprinkler.No Additional Sprinkler is Required. o% z Y 2 .'It' j s 7. WATER SHUT OFF VALVE IS NOT PERMITTED THAT ISOLATES THE SPRINKLER SYSTEM. Caution: If you will be installing spray foam insulation,make sure to m g o y t 8. OWNERS MANUAL MUST BE PROVIDED TO THE OWNER. Senju RC-RES:Traditional Wood Framing Construction protect all components during application.Consult with the spray foam < ..e r p ❑h s p K manufacturer to ensure compatibility with all products before application. NFPA 13D Table 7.5.5.3 Distances From `W°z a z< i 9. AT THE MAIN SHUT OFF VALVE,A TAG OR A SIGN STATING THE FOLLOWING IS REQUIRED;"WARNING,THE Heat Sources =y w z v m-' w-< WATER SYSTEM FOR THIS HOME SUPPLIES FIRE SPRINKLERS THAT REQUIRE CERTAIN FLOWS AND Consultation with local building officials is encouraged to ensure compliance 69.2. z z u:c m PRESSURES TO FIGHT A FIRE.DEVICES THAT RESTRICT THE FLOW OR DECREASE THE PRESSURE OR ProPEX LE'Brass Fire with local building codes. a a o m 5-x AUTOMATICALLY SHUT OFF THE WATER TO THE FIRE SPRINKLER SYSTEM,SUCH AS WATER SOFTENERS, Sprinkler Adapter Tee Fire Sprinkler Adapter Ordinary Intermediate z o m LL i i o 3 < FILTRATION SYSTEMS AND AUTOMATIC SHUT OFF VALVES,SHALL NOT BE ADDED TO THIS SYSTEM p Push-on Nut Neat Source Temp. Temp. a«z H a a p C"C F z WITHOUT REVIEW OF THE FIRE SPRINKLER SYSTEM BY A FIRE PROTECTION SPECIALIST.DO NOT REMOVE r� 13S°-170• 175•-225• i o< > �. k-z THIS SIGN". Bending PEX Tubing S?zeca ,°ii<«o,o > < / 1 Side of Fireplace 36" 12" D R fi z z p a s w u C/ 1/4"Min. The minimum bend radius of Uponor PEX tubing in any direction is six times Front of Fireplace 60" 36" Pa"�--'2<d < 10. ALL INTERIOR PIPING TO BE UPONOR"AquaPEXS"UNLESS NOTED. 1 'Max. the outside diameter(6 x OD). W'a o m H F:2.z . Fire Sprinkler Adapter Bottom of Mounting Bend supports are available for 3/8",1/2",3/4"and 1"Uponor Aqua PEX Wood Buming Stove 42' 12" M .'40•..--. 22%.,9-, i r 11.UPONOR"AquaPEX°TUBING TO BE SUPPORTED PER NFPA 13D AND MANUFACTURERS RECOMMENDATIONS. MountingBracket Bracket to Mrruss ,._F zt-„>3 tubing to facilitate 90-degree rigid bends. Kitchen Range 18" 9' rz o cz9 z a_< z / n l Wall Oven 18" 9' U a "ou�u� �w� 12. MINIMUM SPACING BETWEEN SPRINKLERS IS 8'-0" REFER TO SPACING CHARTS FOR MAXIMUM SPACINGJam{'] \ Recommended Tubing Length Between FittingsfD ,n o>>° ^ > Zul Course x 1 i/2" "` """ ))) Hot Air Flues 18" 9' t,4 <i m u z z BETWEEN SPRINKLERS AND FROM WALLS.SPRINKLER HEAD MANUFACTURERS MAY HAVE MORE Full RESTRICTIVE SPACING LIMITATIONS. Thread Screws �f t I } Fitting Size Minimum Tubing Length Uninsulated Heat Ducts 18" 9" C ta"o i ti m e a z s In Top Holes L7 V-IJ [_/ 3/8'ProPEX Fitting 2" Uninsulated Hot Water Pipes 12" 6" s'f o z r S°O_i 9i-o 13. SPRINKLERS ARE NOT NECESSARILY CENTERED IN ROOMS DUE TO LIGHT FIXTURES OR OTHER CEILING Side of Hot Air Diffuser 24" 12"- z u u i F o a tt z Si o y o MOUNTED OBSTRUCTIONS. 3 1/2"ProPEX Fitting 2 1/2" Front of Hot Air Diffuser 36" 18" ;^o m xi-a x>> u<w< `daz,aau.2W 14. THE PLUMBING TIE IN CONNECTIONS ARE SCHEMATIC IN NATURE AND CAN BE INSTALLED OFF THE = 3/4"ProPEX Fitting 3 1/2" Ho[Water Heater 6" 3' z o><:o y'i?w SPRINKLER LOOP ANYWHERE BETWEEN SPRINKLER TO SPRINKLER CONNECTION. Lead-FregFlat- � o p o u c Y o w v+o >o Concealed Senju 4 Concealed Flat 1"ProPEX Fitting 4 1/2° Furnace 6° 3' o c ro s p O,w e �<F r o Sprinkler Head <x 15. THIS SUGGESTED LAYOUT IS BASED UPON INFORMATION PROVIDED BY OTHERS. CHANGES IN Cover Plate 1 1/4"ProPEX Fitting 5 1/2" SOW-250W Light Fixture 6" 3' " ?o H? _-gm-1 CONSTRUCTION OR FIELD CONDITIONS MAY OCCUR WHICH MAY REQUIRE CHANGES TO THE LAYOUT. IT IS 250W-499W U9ht Fixture 12" 6" a u w i r 3 0 o m B v,z a w x�,w,a°xo <o mek°i� w THE RESPONSIBILITY OF THE INSTALLER TO NOTIFY UPONOR TECHNICAL SERVICES OF SUCH CHANGES. - 16.NFPA 13D 8.2.5*OBSTRUCTIONS TO RESIDENTIAL SPRINKLERS Exposed Installation Requirements. F u u u_ • 8.2.5.6' SHADOW AREAS SHALL BE PERMITTED IN THE PROTECTION AREA OF A SPRINKLER AS LONG AS Uponor AquaPEXTe tubing(white)and ProPEXTM EP Fittings and ProPEXTM ` II v`i THE CUMULATIVE DRY AREAS DO NOT EXCEED 15 FR PER SPRINKLER. Brass Fittings are approved for exposed installation where the following • 8.2.5.7 SMALL AREAS CREATED BY ARCHITECTURAL FEATURES,SUCH AS PLANTER BOX WINDOWS,BAY conditions are met.(UL 1821 Approved) WINDOWS,AND SIMILAR FEATURES,SHALL BE EVALUATED AS FOLLOWS: �/� (1)WHERE NO ADDITIONAL FLOOR AREA IS CREATED BY THE ARCHITECTURAL FEATURE,NO Exposed Wood Joist Ceiling Assemblies. 8 rmv �// Um I here bycertify that thisplan,s e 9 fY P ADDITIONAL SPRINKLER PROTECTION IS REQUIRED. 1. Joists are of dimensional lumber,engineered wood,wood I-joist or open ^i °m or report was prepared by me or ui (2)WHERE ADDITIONAL FLOOR AREA IS CREATED BY AN ARCHITECTURAL FEATURE,NO ADDITIONAL web wood joists. mdirect supervision and that I am NI SPRINKLER PROTECTION IS REQUIRED,PROVIDED ALL OF THE FOLLOWING CONDITIONS ARE MET; 2. Joist are of depths from 6-16 inches(152-204 mm). Certifli- I IV (a)THE FLOOR AREA SHALL NOT EXCEED 18 F-fz(1.7 Ma) 3. Joist are of spacing from 12-24 inches(305-610 mm)on center. p (b)THE FLOOR AREA SHALL NOT BE GREATER THAN 2 FT IN DEPTH AT THE DEEPEST POINT OF 4. Joists can be exposed after installation. \ I Q THE ARCHITECTURAL FEATURE TO THE PLANE OF THE PRIMARY WALL WHERE MEASURED 5. Metal pipehangers spacedX ` llir- ALONG THE FINISHED FLOOR. g at maximum 24 Inches(610 mm)on center 1.55" 1,66" Brent 0 tsli " are used. (c)THE FLOOR SHALL NOT BE GREATER THAN 9FT IN LENGTH WHERE MEASURED ALONG THE 6. Listed residential automatic sprinklers of maximum activation 1,. _�r Date: 8/15/1• Reg.No.11: au PLANE OF THE PRIMARY WALL. p z 4' Hanger 1" Hanger CIT Y O F T I G A R temperature rating of 155°F(68°C). n (d)MEASURED FROM THE DEEPEST POINT OF THE ARCHITECTURAL FEATURE TO THE SPRINKLER j !' i`b SHALL NOT EXCEED THE MAXIMUM LISTED SPACING OF THE SPRINKLER. Tubing Support Spacing: Metal Tubing Support. (Anchor Aqua PEX Tubing Securely Enough to Support the Tubing,Yet Relaxed v (3)THE HYDRAULIC DESIGN SHALL NOT BE REQUIRED TO CONSIDE0.THE AREA CREATED BY THE Approved 1. Metal tubing supports designed for plastic tubing shall be used. Enough to Allow the Tubing to Expand and Contract) v ARCHITECTURAL FEATURE. ,J 2. Do not use supports that will damage the tubing.Inspect metal 2.,' 17. NFPA 13D 8.3 LOCATION OF SPRINKLERS. Conditionally Approved [ ] supports for sharp edges. 3. Do not rigidly anchor Uponor TMtubing supports. 1. Along Horizontal Runs,Install Supports Every 32",If Horizontal Runs are • 8.3.1 SPRINKLERS SHALL BE INSTALLED IN ALL AREAS EXCEPT WHERE OMISSION IS PERMITTED BY 8.3.2 AquaPEX with Allow Continuously Supported,Place Tubing Supports at Six-Foot Intervals. THROUGH 8.3.8. See Letter to: Follow [ ] enough tubing for freedom of movement to expand and contract. 2. Along Vertical Runs,Install Supports Every Four to Five Feet,at Each o • 8.3.2 SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF 55 FT=(5.1 M°)AND LESS Floor and at a Mid-story Guide. CO • 8.3.3 SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS,LINEN CLOSETS,AND PANTRIES THAT Attached ] I 'i o MEET ALL OF THE FOLLOWING CONDITIONS: of (1)THE AREA OF THE SPACE DOES NOT EXCEED 24 FT.(2.2 Mz). /� l" AO 3 In-line Flow Test to m Y (2)THE WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE Permit Number:/a•� The In-line Flow Test can be constructed on site. It performs a flow test to Z g ..... m m Wel 71 SW 4 Standard Riser Assembly ensure proper system operation and flow(see Figure F001-8). j o N N 8 MATERIALS AS DEFINED IN NFPA 220,STANDARD ON TYPES OF BUILDING CONSTRUCTION. I In a multi-purpose �..Lj m • 8.3.4° SPRINKLERS SHALL NOT BE REQUIRED IN GARAGES,OPEN ATTACHED PORCHES,CARPORTS,AND Address: /6 p rpose systema single control valve controls both domestic and , l F SIMILAR STRUCTURES ^/t al C fire safety needs. V By: A� Date: [ 7 _7 Uponor AquaPEX , m m uuni m m 8.3.5 SPRINKLERS SHALL NOT BE REQUIRED IN ATTICS WITH OR WITHOUT STORAGE,PENTHOUSE Tubing /� • EQUIPMENT ROOMS,ELEVATOR MACHINE ROOMS,CONCEALED SPACES DEDICATED EXCLUSIVELY TO AND / /�/ ¢ W CONTAINING ONLY DWELLING UNIT VENTILATION EQUIPMENT,FLOOR/CEILING SPACES,ELEVATOR SHAFTS, j Ll_ m a CRAWL SPACES,AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENDED FOR LIVING j t PURPOSES. Z a a • 8.3.5.1 SUCH SPACES THAT CONTAIN FUEL-FIRED EQUIPMENT SHALL ALSO COMPLY WITH 8.3.5.1.1 OR I a� rt. I /O G a.W ge 8.3.5.1.2. /'/// 'v •• UNIT,NO K THE FUEL-FIRED EQUIPMENT IS ARALL OF THE OCCUPIED AREAS OF THE DWELLING �� / • � F i^zI VC v UNIT,NO SPRINKLER PROTECTION SHALL BE REQUIRED IN THE CONCEALED SPACE. LL O O a Em • 8.3.5.1.2 WHERE FUEL-FIRED EQUIPMENT IS BELOW OR ON THE SAME LEVEL AS OCCUPIED AREAS OF THE I Male Threaded Coupling / ProPEX Fire JJ DWELLING UNIT,AT LEAST ONE QUICKRESPONSE INTERMEDIATE TEMPERATURE SPRINKLER SHALL BE _��I Sprinkler Adapter i INSTALLED ABOVE THE EQUIPMENT OR AT THE WALL SEPARATING THE SPACE WITH THE FUEL-FIRED m EQUIPMENT FROM THE OCCUPIED SPACE. 1"Ball Valve 1---I• 8.3.6 SPRINKLERS SHALL NOT BE REQUIRED IN COVERED,UNHEATED PRO]ECiIONS OF THE BUILDING AT To Hot Water Heater Male Threaded Coupling LL u ENTRANCES/EXITS AS LONG AS THE DWELLING UNIT HAS ANOTHER MEANS OF EGRESS. .9u, Female Threaded 8.3.7 SPRINKLERS SHALL NOT BE REQUIRED FOR CEILING POCKETS THAT MEET THE FOLLOWING _ E Foil Tee with Water • CONDITIONS: v 7ce (1)THE TOTAL VOLUME OF ALL UNPROTECTED CEILING POCKETS IN A COMPARTMENT DOES NOT EXCEED $' Pressure Gauge ¢'S 100 FT.(2.83 Ma). % N Sprinkler Orifice '- (Optional) g Q ® o x 0 Tx (2)THE ENTIRE FLOOR UNDER THE UNPROTECTED CEILING POCKET IS PROTECTED BV THE SPRINKLERS w '° i ti x la' AT THE LOWER CEILING ELEVATION. °` E Y Uponor Warning Signs $x i m (3)•THE INTERIOR FINISH OF THE UNPROTECTED CEILING POCKET EXCLUDING DECORATIVE .u, L.'.1 Flow Test v, TREATMENTS IS NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE MATERIAL. ri me To ensure the system provides enough water for proper fire sprinkler Q m m V. ce (4)SKYLIGHTS NOT EXCEEDING 32 FT°(2.97 M°)SHALL BE PERMITTED TO HAVE A PLASTIC COVER. 8 performance,you should conduct a flow verification test. • 8.3.8 SPRINKLERS SHALL NOT BE REQUIRED IN CLOSETS IN GARAGES AND EXTERIOR CLOSETS x LL Q 9 (REGARDLESS OF SIZE)LOCATED ON EXTERIOR BALCONIES,EXTERIOR BREEZEWAYS/CORRIDORS,OR m Note: The NFPA 13D Installation Standard does not require flow V/ /rl ,t.•. 5:m oi ACCESSED FROM OUTDOORS WHERE THE CLOSET DOES NOT HAVE DOORS OR UNPROTECTED n .. verification. V imp€gi PENETRATIONS DIRECTLY INTO THE DWELLING UNIT. < O ~ a:Y Z Main Fire Sprinkler o i w 0 8.3.9 SPRINKLERS SHALL BE INSTALLED IN ANY CLOSET USED FOR HEATING AND/OR AIR-CONDITIONING c z Shut-off Valve Before ingthe performing Watera Flow verification test,confirm the watery. Ensure by H :°°-, EQUIPMENT,WASHERS AND/OR DRYERS,OR WATER HEATERS EXCEPT AS ALLOWED BY 8.3.8. c contacting the and Sewer Department of your local city. Ensure the p >S available water pressure matches the pressure used In the system design. SHEET DESCRIPTIO 18. INSULATION GUIDE LINES PER NFPA 130. c Note: The sprinkler plan indicates the most hydraulically remote sprinkler o` • 9.1.1*WET PIPE SYSTEMS IN AREAS ABOVE 40°F. A WET PIPE SYSTEM SHALL BE PERMITTED TO BE TO BE c o (or pair of sprinklers). For test requirements on other sprinklers,consult GENERAL NOTES&DET, i USED WHERE ALL PIPING IS INSTALLED IN AREAS MAINTAINED ABOVE 40°F,INCLUDING AREAS PROPERLY your local code. INSULATED TO MAINTAIN 40°F. A.9.1.i IN AREAS SUBJECT TO FREEZING,CARE SHOULD BE TAKEN IN UNHEATED ATTIC SPACES TO Note: It is a good idea to notify the fire inspector at least 24 hours prior to >u COVER SPRINKLER PIPING COMPLETELY WITH INSULATION. INSTALLATION SHOULD FOLLOW THE performing a flow verification test. This may speed up the inspection