Loading...
Report \Q - c.c.)\\O S1,6 S,e l\nA \ P POTTERRECEIVED AFC 50 • The Symbol of Protection AUG 2 7 2019 Fire Alarm Control Panel CITY OF TIGARD BUILDING DIVISION Features em8% • 50 addresses available on this analog addressable system • Additional system capacity achieved via multi-point SLC modules iy >9 • 99 software zones tiff • NFPA 72 Compliant Smoke Sensitivity Test Built-In Op • System Operates as Class A or Class B for SLC,P-Link and NACs AFC-so • 5 Amp Power Supply,Expandable to 310 amps • 2 NACS,Regulated,Rated at 3 Amps each,expandable to 188 • 2 Input/Output WO)Circuits for system flexibility rated at 1 Amp each • Strobe Synchronization and System Wide Sync for Gentex®, AMSECO®,Cooper Wheelock®and System Sensor®strobes • Dedicated Alarm,Supervisory and Trouble Relays • 4,000 Event History Buffer • Optional two line DACT with UD-1000 that can report General,Zone or Point Information • Built in IP Communicator • Ethernet Port for Programming and Network Connectivity • E-Mail System Status,Reports and Event Informationsum NYC Fire Dept. ((' • Product includes 5 year warranty. Certificate of Approval `i APPROVED 6256 LISTED 7165-0328:0509 S735 Description Technical Specifications TheAFC-50 is an analog/addressable fire alann system with a total system capacity of 50 addresses.Additional capacity on the system is achieved Dimensions 16"W x 17"H x 3 7/8'D using multi-point SLC modules.The control panel utilizes the exclusive 3.0 Amps @ 120 VAC 50/60 HZ Potter protocol that includes a complete line of sensors and modules. AC Mains 2.0 Amps @ 240 VAC 50/60 HZ Each SLC may be comprised of any combination of smoke sensor,heat detectors or modules and allows for a total of 50 ohms of impedance and Enclosure 16 gauge cold rolled steel with removable may use any wire compliant with the National Electrical Code(NEC). locked door with Lexan viewing window The AFC-50 has a 5 Amp power supply with two Notification Appliance Standby Current-130 mA Circuits(NACs)and two Input/Output(1/0)circuits.TheNACs are rated at Alarm Current-200 mA 3Amps each and the UOs are rated at 1 Amp each.Each output is regulated 5 Amps power for NACs UO,and P-Link •and power limited.In addition,each output is uniquely programmable and Battery 3 Amps per NAC,regulated maybe configuredfor • 1 Amp per I/O circuit,regulated steady signal, strobe synchronization, constant • Battery Charger range 8-55 Ah power, door holder power, or releasing. The strobe synchronization • Battery Charger voltage 27.3 VDC includes Gentex,AMSECO,System Sensor and Cooper/Wheelock and • p-Link maximum current of 1 Amp - with the exclusive Quadrasync each output may have a unique brand and all strobes will flash together. Temperature and 32°to 120°(0°C to 49°C)with a maximum Humidity Range humidity of 93%non-condensing. The NACs may be expanded using the PSN-l000 series intelligent power supplies. Each PSN-1000 adds another 10 Amps of power,2 additional input circuits and the AFC-50 will support up to 31 power supplies.The system will synchronize the strobes system wide.In addition,the PSN- 1000E has space to allow the installation of up to six expansion cards. The cards mount on a stacker bracket that allows access to all circuit connections. • Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830133-REVD • 3/19 PAGE 1 OF 4 P POTTER AFC-50 • The Symbol of Protection Fire Alarm Control Panel SLC Loop Accessories The control panel may be connected with up to 50 addressable devices or modules in any combination.The SLC is not restricted by any special wire requirements and may be wired with any wire that complies with the NEC. SLC Loop Devices Device Description PAD 100-PD Analog Photo Electric Smoke Detector is a smoke detector with a listed obscuration of 1.02 to 3.83 percent per foot. PAD100-PHD Combination Analog Photo Electric Smoke/Heat Detector—a smoke detector with a listed obscuration of 1.02 to 3.83 percent obscuration and a fixed temperature 135°Fahrenheit heat detector. PAD100-HD Analog Fixed(135d-185dF)or Rate-of-Rise Heat Detector(software selectable) PAD100-DUCTR Addressable Duct Smoke Detector with Form C Relay.Addressable Duct Smoke Detector with Form C relay rated at l0a @ 250/120VAC or camps at 30VDC. PAD 100-DUCT Addressable Duct Smoke Detector. PAD100-6B 6"round base that is mounted to an electrical box and wired for connection of one of the above sensors. PAD 100-4B 4"round base that may be mounted to an electrical box and wired for connection to the above sensors. PAD 100-IB Isolator base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop. PAD 100-RB Addressable Relay Base that contains one relay controlled by the SLC.Relay is rated at rated at 2 amps at 30 VDC or 0.5A at 125VAC. PAD 100-SB Addressable Sounder Base that contains an addressable sounder module that may be configured for local,group and all call. PAD100-CD Addressable CO gas detector. PAD 100-DD Addressable photo electric smoke detector for use in DUCT/DUCTR enclosure. PAD100-LFSB Addressable Low Frequency Sounder Base that contains an addressable sounder module that may be configured for local,group and all call. The LFSB complies with the Low Frequency Signal Requirements(520 Hz) PAD 100-SPKB Speaker base is a wall or ceiling mount speaker capable of 25 or 70.7 VRMS and is field selectable from 1/8W to 4W. Modules Device Description PAD 100-MIM Micro Input Module provides a small foot print contact module for mounting inside an enclosure. PAD100-PSSA Single Action Addressable Pull Station. PAD100-PSDA Dual Action Addressable Pull Station. PAD 100-SIM Single Input Module is a standard contact module with an LED that mounts into a 4"square electrical box. PAD 100-DIM Dual Input Module is a device that can monitor two distinct inputs with a single device or in a Class A mode. PAI)100-TRTI Two Relay Two Input module provides two form C relays that are individually controlled by the control panel.Each relay is rated for 2 amps at 30VDC or 0.5 amps at 125VAC.Also provides two contact inputs. PAD 100-NAC Notification Appliance Circuit module is an addressable remote appliance circuit controlled by the panel. PAD100-ZM Zone Module is used to connect conventional 2-wire smoke detectors to the system. PAD100-IM Isolater Module interrupts a short on the SLC and prevents the short from affecting protected devices on the loop. PAD100-RM Relay Module that provides one form C relay controlled by the control panel.Relay is rated for 2 amps at 30VDC or 0.5 amps at 125VAC. PAD 100-LED Module provides a single addressable LED that is controlled by the control panel. PAD100-SM Speaker Module provides switching for two audio channels. PAD100-LEDK Addressable LED and key switch that mounts in a single gang box. ` PAD 100-DRTS DUCTR Remote Test Switch that mounts in a single gang box and optionally supervised.For use with the PAD100-DUCTR only. PAD100-OROI One Relay One Input Module provides one form C relay and one input.The relay is rated at 2 amps at 30VDC or 0.5 amps at 125VAC. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830133-REVD • 3/19 PAGE 2 OF 4 P POTTER AFC-50 • • The Symbol of Protection Fire Alarm Control Panel SLC Features RA-6500R(F)—4 x 40 LCD annunciator with a key pad in a locked The Potter protocol is a digital protocol with a proven design for metal enclosure.Flush mount version available. reliability and noise immunity.The system does not require special LED-16(F)—16 LED annunciator with common indicators in a cable or conductors for connection of the Signaling Line Circuit locked metal enclosure.Flush mount version available. as long as the cable is compliant with NFPA 70 and NFPA 72. PSN-1000(E)—10 amp,remote intelligent power supply with The system allows for Class A or Class B installations as well as 6 NACs,2 I/Os and a P-Link repeater.This panel is listed in "T-Taps",with a max wiring distance of 10,000 Ft. conjunction with the AFC-50 as releasing circuits. Sensor Features CA-6075—Class A convertor that converts the SLC,NACs and The sensors through the fire alarm control panel provide a real P-Link connection time status as to the condition of the system.The smoke detector UD-1000—UL listed,Dual line telephone alarm communicator sensitivity,heat detector temperature level and drift compensation DRV-50—LED driver expander,used to connect up to 50 LEDs in a are all programmable options.The system also allows for a day/night graphic display mode where the panel automatically adjusts the sensitivity depending FCB-1000—Fire communication bridge,provides remote mounting on the time of day.To assist in the reduction of false alarms,the of the Ethernet connection smoke detectors also have a maintenance warning that sends a trouble FIB-1000—Fiber interface module,used to extend P-Link to multi- signal when a detector is dirty to the point that it can no longer mode fiber(2 required) maintain the programmed sensitivity. RLY-5—Relay module,provides 5 form C relay contacts rated at 3.0 User Interface amps 24VDC/125AC The fire alarm control panel has a 2 x 16 LCD display to provide SPC-1000—Serial parallel gateway,allows for the connection to a information to the system status.The keypad has navigation keys serial or parallel printer to allow manipulation of the Menu on board the panel.The panel is The FIB-1000,FCB-1000 and the SPC-1000 may be installed in the shipped standard with the following LEDs: stacker bracket or ordered with the optional rack mount enclosure. • AC Power-Green MC-1000 Multi-Connect allows up to sixty-three AFC series panels • Alarm-Red to share a single reporting technology. • Earth Fault-Amber IDC-6—Initiating device circuit provides 6 programmable inputs AE-2—Two card expansion cabinet • Supervisory-Amber AE-8—Eight card expansion cabinet • Silenced-Amber AE-14—Fourteen card expansion cabinet • Trouble-Amber Ethernet/I.P. Connection • Pre-Release-Amber The AFC-50 is shipped standard with an Ethernet connection. • Release-Red This connection is the programming port and may be connected to a building Wide Area Network(WAN)or Local Area Network The common buttons include a Silence,Reset,Acknowledge,and (LAN).Once connected to the Internet,the panel may be selectively Drill.All of the buttons are accessible once the locked door is programmed to e-mail alarm conditions,trouble conditions, opened. supervisory conditions,test,Event History and detector status.An P-Link e-mail may be sent to the panel and the panel will e-mail the event The AFC-50 has a proprietary communication protocol that history,detector status,configuration file or server status to an communicates through a RS 485 connection to field devices.Upauthorized E-mail account.In addition,relders may be set to send to 32 devices may be connected to a single P-Link connection.The ane-mail for service,testing or other conditions. P-Link includes the communication terminals and regulated 24 VDC In addition,the Ethernet connection is UL listed as an IP connection for the field devices.The field devices may be any of the communicator.The IP communicator is listed to report to the UL following: listed Sur-Gard III IP receiver.The IP communicator replaces the PAD100-SLCE-Analog/Addressable loop expansion module traditional less reliable alarm communicator transmitter that utilized SLCE-127-Nohmi addressable loop expansion module for retrofit telephone lines.The IP communicator is an active method of applications. connection and communication to the monitoring station. RA-6075R—2 x 16 LCD annunciator with a key pad in a locked metal enclosure. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830133-REVD • 3'19 PAGES OF 4 P POTFER AFC-50 The Symbol of Protection Fire Alarm Control Panel Dimensions • ® ©- f TOP • DEP+ITH=3.75' J 0 • 1 ' DOOR= 16.07° BACKBOX=15.77' DEPTH=3.84' 10 .: i I I • Ce o 0 ( © 00 CO a Q co •°• •. • LEFT SIDE J RIGHT SIDE BOTTOM • DWG=5931 Ordering Information Model Description Stock No. AFC-50 Fire Alarm Control Panel 3992752 Replacement Board AFC-50 3992756 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830133-REVD • 3/19 PAGE 4 OF 4 P POTTER UD-1000 • The Symbol of Protection Digital Alarm Communicator Features /,0".% • Allows for communication to Monitoring Station • Communicates using SIA-DCS or Ademco Contact ID Protocols f ' 0` • For use with 6000 series and P series Addressable Panels - , '` c R F • Status LEDs indicate operation of DACT card • Installs with ease behind main panel LCD display via User Interface bracket • Device address is set by dipswitches located on DACT card °`'' • Installation materials including 4 pin connector and screw are supplied • ." with DACT card Nark • UUKL Listed with Smoke Control 'x • i t i 4 41f; • ti (r4) 10111, APPROVED LISTED ll S735 7165-0328:0195 Description Technical Specifications The UD-1000 Digital Alarm Communicator Transmitter (DACT) Operating Voltage 22.0-24.0V provides for up to two (2) phone lines for communication to a monitoring station. The UD-1000 communicates using the SIA- Standby Current 16mA DCS or Ademco Contact ID protocols. When enabled, the DACT Alarm Current 23mA automatically monitors each phone line or voltage and has the Max UD-1000s per panel 1 ability to seize the line and connect with a remote receiver.Once the communication is complete,the DACT will hang up. Dimensions 4"W*6"H* 1-5/8'D The DACT is provided with an RJ-11 jack for each phone line and a Operating Tempuratures 0°C-49°C(32°F-120°F) RJ-11 to RJ-33 cord.In order for the DACT to work properly,it must HumidityRange 10%-93%@ 30°C(86°F) be installed on a plain old telephone service(POTS)line or equivalent Opera (non-condensing) deemed by the authority having jurisdiction. The DACT must be Mounting Options In FACP Behind keypad installed before any other equipment to ensure it can seize the phone Shipping Weight 0.47 lbs line. Phone lines are high voltage and should be run in a separate conduit from other circuits.The wire conductors connecting the DACT to the phone system sligukt be 26 AWG or larger. Potter Electric Signal Company,LLC • St. Louis,MO • Tech Support: 866-956-1211 /Customer Service: 866-572-3005 • www.pottersignal.com 8830048-REV B • 12/18 PAGE 1 OF 2 P poTTER U D-1000 The Symbol of Protection Digital Alarm Communicator • UD-1000 DACT Installation on UD-1000 DACT Installation on . PFC-6030/6075R PFC-6800/6200 Fig 1 Fig 2 j. e e I i � 11 aha E. o ,. I � ih�� e as ►® ODD tm® �� :�,El ®OO IQH .r �O�� � • li ' P ■ 44 iiv 1] i: UD-1000DACT ---- l II Ra ij Slides in guides under main board. 1 cz 41q111111111111111 a O Q�l R 4- O DWG♦593-32A / _-- #1Illb 111.11 .. 'r2 I _ t - - - i 4 . lifr I..:. :&--H= __________ LT SII a It ■ r P Connector T.. , . on PFC-6075 " main board R a �� u' ®� b,F®p_ P Connector .a, �� on PFC-6800 1'"`'on a D main board NOTICE — I ,3 :'' � p'■ � Install in accordance with compatible fire alarm control panel ����� R installation manual __ =='.J '_r��.. ..fie Installation The UD-1000 DACT is connected to the control panel using the provided four-wire cable connection(P/N 5210514)between P4 and UD-1000 P1.The connection is power limited and supervised. 1. Power system down. 2. Slide the UD-1000 into the card guides located under the User Interface bracket. . 3. Secure the UD-1000 to the User Interface bracket using the provided#6-32x3/8"screw 4. Install the provided four-wire conductor jumper between UD-1000 P1 and P4. Potter Electric Signal Company, LLC • St. Louis,MO • Tech Support: 866-956-1211 /Customer Service: 866-572-3005 • www.pottersignal.com UM Min Mane I DESIGNING,MANUFACTURING, CERTIFIED &DISTRIBUTING QUAI.IiYSYSTEMs 8830048-REV B • 12/18 PAGE 2 OF 2 StarLinkCommercial Fire Alarm Cellular &/or IP • • COMMERCIAL FIRE CELLULAR& IP Fire Alarm Communicators - • Universal full event sole&dual path cellular BJor IP commercial UL and NFPA 72 Fire Code-Compliant,the StarLink Series fire alarm reporting from any panel brand,virtually anywhere Wireless Commercial Fire Alarm Sole Path&Dual Path nationwide Communicators provide universal support for any brand - • Code-compliant,replaces 2 POTs lines per FACP saves thousands 12V to 24V fire alarm control panel,reporting in Contact of dollars per year over the leased landlines ID and 4/2. With broadest LTE coverage footprint,Verizon or AT&T,using proven StarLink circuitry,they are also • Supports 12V-24V control panels and FACPs that communicate using available in locking metal models.All provide the most Contact ID and 4/2(such as on legacy panels),as primary or backup economical solution for easy,versatile installation.Also • Full data Reporting to any Central Station nationwide,via choice regional compliances,i.e.,CSFM,NYCFD, LAFD and more. of LTE Networks,Verizon®or AT&T®. Communicate critical life Easy,Universal Installation at Every Application;Panel- and safety alarm reports on LTE(Long Term Evolution)10+year Powered TechnologyTM'.StarLink Fire Communications are life,cyber-protected multi-billion dollar cellular network,for maximum life safety&liability protection. easily connected to any panel or Fire Alarm Control Panel (FACP)standardly operating between 12V and 24V.Flexible • Proven to work even where other's won't-using Signal Boostm1 in any application,StarLink Fire also comes in standard,or &twin dual diversity antennas- Max.signal acquisition&null models in metal housings,with code-compliant supervision, avoidance(receives signals simultaneously on both antennas) and choice of power options,Panel-Powered Technology" • Easiest installation,powered by panel,NO extra power supply, (powered by the panel),or direct-connect 120VAC models. NO extra conduit.(Excludes Direct AC-Powered "-PS"models,with Signal Boost circuitry&dual diversity antennae for transformer option.)t maximum signal acquisition&null avoidance,receiving • Dual Path Cellular/IP Models Save Time&Money-Uniquely signals simultaneously on both antennae. including 4 programmable EOLR zone inputs;2 Form C Relay outputs Flexible Performance&Reporting Options.StarLink Fire (no extra supervision modules to buy or install);plus,2 Telephone- provides full data reporting,in sole and dual path,as a style jacks for easy FACP-connection.Self-supervised on 4 wires. primary or backup,to any central station of your choice, • Preactivated to ensure communications-saves time and labor onsite without requiring any special equipment on premises. Ultra-affordable plans are available to meet various codes • LED Status/Trouble Indicators 3 Radio Status LED Indicators and requirements,with supervisory check-ins from 200 (visible from outside standard model housing)-Green,Signal seconds,to 5 minutes;and/or from 1 to 6 hours.The units Strength;Amber-Busy/Activation;Red-Trouble(4 additional LEDs, are very easily activated, plans and options are selected, not visible,for network status&troubleshooting).Power LED and 24/7 account management is provided all through indicator viewable on outer metal enclosure models. www.napcocomnet.com. • Over-the-Air Upgradable Communicator Firmware.Remote ability for critical/mandatory updates,without a truck-roll • Cost-saving models and plans for any code requirement. Napco StarLink Universal Fire Alarm Dramatic savings over monthly dedicated landline charges. Communicators • Sole Path Cellular and Dual Path Cellular&/or IP Models • Choice of LTE Networks,Verizon or AT&T models • Choice of plans(varies by model)-check-ins from 200 seconds to 5-minutes,and from 1 hour;up to 6 hours for dual path • Patented Signal Boost'mand Dual Diversity Antennae for maximum signal acquisition&null avoidance,receiving signals simultaneously on both antennae • Money-saving Tradeup incentive credit for security professionals,on new or retrofit fire systems,i.e.,tradeup missing/retired POTs lines,old radios&networks or new installations • Bonus:Full High-Speed Napco Panel remote uploading! downloading • COMPLIANCES:NFPA 72 Editions:2019,2016,2013,2010, 2007;UL 864,10th Ed.,UL1610,UL985,UL1023,NYCFD; SWUM( CSFM;LAFD connected by • AT&T ver`izon N MI Code-compliant standard or metal models on choke of Verizon or AT&T LTE networks. �...r- „ r Start_ink --- ,: Commercial Fire Alarm Cellular &Ior IP � . • COMMERCIAL FIRE CELLULAR .''IP Fire Alarm Communicators - Model Ordering & Specifications verizon AT&T Unique Onboard Other Power LTE Cell IP WiFi Labor/Cost-Saver Electrical Input Inputs Input Ratings Outputs Output Ratings Supply - Network Option" Features Palings {option)' STANDARD MODELS(ABS) 5.38x7-88x1.88"(HIND) SOLE PATH Panel-Powered Tech SLE•ITEIRE AT&T Yes No No `y:' A•F Input Voltage/Input IN1:9-25VDC Max input pGM1, Open Collector Outputs Max Current: 10V=90mA; IN1,IN2, current 2mA IN2,1N3: 3V when active,Max 25V PGM2, 12.25V=71mA, IN3 9-25VDC Max input P6M3 when not active.Max current SLE-LTEV-FIRE Verizon Yes No No 200mApeakduring current1.2mA 24mA@25V transmissions DUAL PAN 2 TelCo jacks for EZ Panel-Powered Tech':TM SLE-LTEAI-FIRE AT&T Yes Yes Yes FACP Connect;4 y NiI :9-25VDCMax OUT1,OUT2:Dry Contact,Form Programmable EOLR Input Voltage:l0.25VDC INi,IP42, nputcurrent2mA OUT1, CRelay,30VAC/DC,500mA Input Current:162mA Max PGM3:Open Collector zone inputs;2 Form C IN3,1N4, IN2,IN3,IN4,IN5: OUT2, Relayoutputs(avoids to 100mA standby; Outputs Max 3V when active, P 300m/ durin INS 9-25VDC Max input PGM3 SLE•LTEVI-FIRE Verizon Yes Yes Yes egt for supervision peakg current1.2mA Max 25V when active.Max n.. transmissions current 24mA@ 25V MODELS IN METAL ENCLOSURE 9.63 r.11-75 r.3.38",1.-OhlID1 SOLE PATH Panel-Powered Tech'y SLE-LTEA-CFB AT&T Yes No No :'t Input Voltage/Input IN1:9-25VDCMaxinput PGM1, Open Collector Outputs Max Current:10V=90mA; IN1,IN2, current 2mAIN2,IN3: PGM2 3V when active,Max 25V • 12-25V=71mA, IN3 9-25VDC Max input pGM3 when not active.Max current SLE-LTEV-CFB Verizon Yes No No 200mApeakduring current1.2mA 24mA@25V transmissions - SLE-LTEA-CFB-PS AT&T Yes No No Direct AC-Powered:Input Voltage.12OVAC nominal tN1 (N2, INcur current 2mQ N2,IN9-25VDC Max 3 ut PGM1, 3Vwhen aOen Colctive,Max Out25Vans when uts MaxTr( TRF12 ormer Input Current 150mA PGM2 , max;maximum charging IN3 9-25VDC Max input pGM3 not active.Maximum current 16VAC,20VA SLE-LTEV•CFB-PS Verizon Yes No No current:200mA current 1.2mA 24mA@25V transformer) DUAL PATH 2 TelCo jacks for EZ Panel-Powered OUT1,OUT2:Dry Contact,Form SLE-LTEAI-CFB AT&T Yes Yes Yes FACP Connect;4 IN1:9-25VDCMax ProgrammableEOLR Input Voltage:10-25VDC: INi,IN2, nputcurrent2mA OUTi, CRelay,30VAC/DC,500mA zone inputs; Input Current: 162mA Max PGM3:Open Collector P Y IN3,IN4, IN2,IN3,IN4,IN5: OUT2, Outputs Max 3V when active, Relay outputs(avoids to10DmAstandb; INS 9-25VDC Max input PGM3 SLE•LTEVI.CFB Verizon Yes Yes Yes reqt envision 300mApeakduring P Max25Vwhenactive.Max q P ulm transmissions currer .2A current 24mA(§25V module) 2 TeICo jacks far EZ OUTT,0UT2:Dry Contact,Form SLE-LTEAI{FBPS AT&T Yes Yes Yes FACP Connect;4 Direct AC-Powered:Input IN1:9-25VDCMax C Relay 30V 500mA Transformer Programmable EOLR Voltage:120VAC nominal IN1,IN2, input current2mA OUT1, Max PGM3:Open Collector (TRF12 zone inputs;2 Form C Input Current:200mA IN3,1N4, IN2,IN3,IN4,1N5: OUT2, Outputs Max 3V when active, 16VAC,20VA SLE-LTEVI-CFBPS Verizon Yes Yes YesMax 25V when active.Max transformer)Relayoutputs(avoids max;maximum charging INS 9-25VDCMaxinput PGM3 Ma regtforsupervision current:200mA current1.2mA current 24mA@ 25V module) ACCESSORIES: SLE-WIFI-MODULE Optionally connects supported dual path models to FireLink' Integrated Fire Alarm Control Internet via WiFi,eliminating Ethernet cable connection.Requires 7AH batty w/StarLink Fire LTE Built In E ("See details WI2191) atm SLE-ANTEXT7S Optional extended range omni.antenna w!75'cable, 9 It. s FL-32FACP-LTEV Firewolf 8 Zone 24V Conventional premium low-loss cable&full mounting hardware&ground fault isolation , Commercial Fire Alarm Control Panel with onboard mounting plate ' ,:; StarLink Fire'x.Sole Path,Verizon LTE Cellular SLE-ANTEXT50 As above,with 50'cable Alarm Communicator and integral menu-driven LCD annunciator,wf 4amp,24V power supply. SLE-ANTEXT30 As above,with 30'cable ;,. - Optionally expandable up to 32 points/zones via TRF12 Optional Plug in AC Transformer,16.5V 120VA(use commercial addressable,wireless or conventional is subject to local code compliance)[ , fire devices(2 onboard ), providing up * v., to 4A notification power).Locking,metal red ' enclosure,(surface or flush mount')removable Free Commercial Fire LTETradeup Trifold ', 4` 16•'x17"door w/14.25"x16"base.Houses 16Ah Brochures/Mailers/Stuffers(A747) ' battery backup. StarLink Fire - (.., 333 Bayview Ave.,Amityville,NY 11701 • 1-800-645-9445 • www.napcosecurity.com Note.Always consult technical manual and/or ADI for compliance requirements for yourareafappllkation.StarLink,Startink Fire,Firelink,SignalBoost,Panel-Powered Technoloo,Gemini&Gemini Commercial are trademarks of Napco.AT&T,Yeriton,LTE,etc.are trademarks of their respectivecompanien *StarLink offers full data coverage in US from virtually all panel brands reporting in Contact ID or4/2.tt For Panel-Powered technolog,regulated auxiliary power outputs are required on Listed FACP.**Add 40mA to input current&Standby Battery requirement,tWhere permitted byAlij;requires conduit..For full details on the Starunktradeup incentive see online under http://trwmnapcosecurky.com/starlinkistarlink4gupgrade/[Promo subies to change w/o poor notice.LTE lifespan claims are based on those of carriers. ©NAPCO,NAPCO Security Technologies Inc.(NASDAQ:NSSC) A734A2019.8 P POTTER PSN SERIES The Symbol of Protection POWER SUPPLY UL,cUL,CSFM Listed • PSN-64 has 6 amps regulated with 4 Outputs • PSN-106 has 10 amps regulated with 6 Outputs • Outputs Rated at 3 amps maximum each • May be configured as up to three class"A"Style"Z"notification circuits • 3 amp,24 VDC programmable output power 1` • Supervised Battery Charger.27.3 @ lA(supports 7-55 All batteries) • Easy to install cabinet with leveling mounts and key lock • Wiring knockouts provided on sides and top of cabinet • Two Trouble Relays(5A at 30VDC) General System Trouble(programmable for AC delay) IP Low AC Trouble with optional delay settings • Diagnostic LED's patent pending Status LED's for Active NAC and NAC trouble conditions Status LED's for EarthFault(Amber),AC(Green),Battery Fault(Amber) .wr. • Trouble Memory feature captures troubles which have previously restored COUS • Synchronized notification appliance circuits LISTED Potter/AMSECO®,Wheelock®,Gentex®,System Sensor® S2930 7315-0328:0189 • Configurable output circuits(DIP switch sets options for each circuit) • 15 mA at 8-33 VDC input trigger Product includes a 5 year warranty • Reference EOL allows 2K—27K EOL value to be used • Quadrasync provides panel wide synchronization of same or multiple brands Dimenions: 16 1/8"W x 16 3/4"H x 3 1/2"D • PassThru mode allows the Outputs to match the Input Signal Electrical Specs: Stock Number: 3006436 PSN-64 Red Enclosure • 120/240 VAC 50-60 Hz input 3006437 PSN-106 Red Enclosure • 5.1 Amps @ 120 VAC or 2.5 Amps @ 240 VAC 3006446 PSN-106 Black Enclosure • Battery Standby Current 75 mA • Alarm Standby Current 75 mA(no external load) • Terminals support 12-18 AWG wire. Description The PSN series of notification power supplies offers reliable notification Sensor®strobe devices.Each output can be configured the same sync power with unprecedented versatility.The power supplies offer either protocol or set independently. 6 or 10 amps of continuous power through 4 or 6 outputs respectively. In addition,the panel has an input PassThru mode allows the outputs Each output is rated at 3 amps and it may be used continuously without to follow the input signal and sync up the input flash.The panel will any derating. recognize the type of input being supplied and pass this through to the The power supply operates on either 120 VAC or 220 VAC power input outputs with the same pattern.This input pass through can be selected and has a regulated 24 VDC output.In addition,the panel can charge on each output independently. up to 55 AH batteries and leads the industry in housing up to 18 AH The power supply contains simple dipswitch programming and LED batteries.The cabinet is constructed out of 18 gauge cold rolled steel and indications providing the installer indications of the operation and the has a durable red powder coat finish.In addition,a key lock is provided ability to correct any faults.A Trouble Memory is provided to allow an for securing the door.Ample electrical knockouts are provided on the sides and the top,allowing the installer options for running wires and installer to review past troubles and make the necessary repairs. Each output has an LED to pin point the exact circuit where a problem may maintaining the correct separations. have occurred Relays are provided for monitoring the general system The power supply offers an industry leading Quadrasync function that and AC failure. allows for multiple strobe circuits of different brands to be synchronized Each output and be independently configured for various applications to flash at the same time.The panel can have four different brands each and installations.Each output can be independently configured for Class connected to its own circuit and all of the strobes flash together. A or Class B operation,constant power,ANSI Temporal Code 3,Single, Each output can independently be configured to provide one of Multiple or Combo Inputs or Door Holder Power. four synchronizations or steady power. This provides unequivocal flexibility in new and retrofit installations.The panel can be configured to synchronize Potter/AMSECO®, Gentex®, Wheelock® and System • Potter Electric Signal Co.,LLC•St. Louis,MO•Cust Service: 866-240-1870•Tech Support: 866-956-1211 •Canada 888-882-1833•www.pottersignal.com PRINTED IN USA MKT.#8910013-REVD PAGE 1 OF 2 1/18 p POTTYPSN SERIES • The Symbol of Protection POWER SUPPLY PSN-106 Wiring Diagram n 120/240 VAC GND FAULT s a Jumper Position DETECT ENABLE 120VAC 50Hz-60Hz ON 1 OFF 240VAC 50Hz-60Hz Black Connect to separate White unswitched AC circuit Ground Status LED's II, 9, NACI CA SACS PWA I�1 ' — / Q• NAC2• NAC3• NA• • NACS• DC• Q �P� 'S7 'S& 0II N o )I H COMM• Fuse K� , O "I'I'I'i" _7 ❑ ❑0 o r: ❑ o --__- 3 ❑ ❑ o idur r,. 0 (—�❑ n ACA pn t E0I 1EI I .ms, Low Battery l 1 • God Fault '-- ■ Connn � 1_ _.J I i t80� 6 8 ❑ 1 9 0 L. ... _ 'Luuu t 1:-.„ii,...-.„, . P79 KD oyi:iu iuuuu '•r ' •. • u 01 {1 `i it o O ,,C1 NAC2 NAC3 NACa C5 NAC6 PC' 'REF. (51 DC Q 777 x.owAC - - + - + - + - + - + '+ Wel - -F{11 - +501 DUIDAT 10., NC COM NO NC COM NO l�Batten., _4 -Banery- t /,. 9 Common relays are O(*teat E.o.L non-power limited. ° -„r-, E.O.L. ii \\, DC Power Trigger Battery eouneedoa(non-power Mea). Note:PSN-64 and PSN-106 draw 15 mA when polarity reverses and the power Use two(2)t2V batteries connected In seriessupply is triggered.There is no current draw in Standby Mode. Engineering Specification The contractor shall supply and install the Potter PSN power supply.The assemblies.The LEDs shall have distinct flash patterns to provide further power supply shall operate on either 120 or 240 VAC input.The panel indication of the troubles present.The panel shall have selectable Trouble shall be capable of continuous load power without any degradation to Memory to provide the installer an indication that a past trouble existed the main supply or the distribution board.The cabinet shtdfbe capable of on a circuit for diagnostic purposes. housing up to 18 AH batteries and the panel shall be capable of charging Each output of the power supply shall be capable of 3 amps of continuous up to 55 AH batteries in an external cabinet power without degradation over time.The power supply shall provide for The panel shall have dip switches for simplistic configuration of the multiple circuits ofstrobe appliances.Thepowersupply shall synchronize system and LEDs to provide visual indication to the installer of the status the flashes of any of the above listed strobe appliances on a per circuit of the system.The dip switches shall allow forAC power delay selection, basis.Up to four different strobe circuits may be connected and all of Class A/B operation per output,Door Holder Power options,constant the strobes shall flash in unison as required by UL 864.In addition to auxiliary power,trigger input type,ANSI Code 3 Temporal Code,Pass this Quadrasync feature,the panel shall allow any of the four above Thru(input tracking),Potter/AMSECO®sync,Gentex®Sync,System mentioned sync patterns as an input and pass this signal through and Sensor®Sync or Wheelock®sync.The LEDs shall provide indication synchronize the outputs to match the input flash pattern. of communication between the power supply and distribution circuit PRINTED IN USA MKT.#8910013-REV D PAGE 2 OF 2 1/18 P P Ti PAD100-PD The Symbol of Protection Photoelectric Smoke Sensor • Features eukt, • Low profile,less than 2 inches with the base " • Wide selectable sensitivity range of 1.0 to 3.7%/foot T►re • Sensor communicates sensitivity to control panel • UL listed smoke calibration and sensitivity • Optional locking tab to prevent unwanted removal • Simple DIP switch address setting,no programming tool required • LED alarm indicator • Product includes a 5 year warranty • UUKL Listed for Smoke Control 11111,1 4::* (0) 13 APPROVED 1 1 LISTED Description Technical Specifications The Photoelectric Smoke Sensor is a listedAnalog Addressable smoke Operating Voltage 24 VDC sensor compatible with fire alarm control panels that utilize the Potter . Addressable Device(PAD)protocol.The PAD100-PD is a low profile Detector Current Draw 300 l A smoke sensor with a wide sensitivity range.The sensor and base(not Alarm indicator 1 LED included)are made of a durable plastic in an off-white color to blend Alarm set-point range 1.0 to 3.7%/ft 3.6-12%/m in with the ceiling. Installation temperature The PAD100-PD has a sensitivity range of 1.0 to 3.7%per foot and 32 to 120°F/ 0 to 49°C is UL. The PAD100-PD features drift compensation and has built in Operating relative 0/o to 93/o(Non-condensing) dirty detector warning as well as. The PAD100-PD and the control 0 0 panel communicate over a proven and robust digital communication humidity range path and the system analyzes the information at the particular device. Start-up time Max. 1 sec. The total polling speed is less than five(5)seconds,well under the UL Maximum number of requirements. addresses per loop 127 The sensor is compatible with any of the PAD series sensor bases and Maximum number of simply twists on. The PAD100-PD is addressed using DIP switches lighted indicators in 30 in the rear of the sensor and can be easily programmed in the field alarm per loop. without special tools. Color Eggshell White Setting the Address Weight(without base) 101g(3.56oz) Each addressable device on the SLC loop must have a unique address Dimensions(without Height: 1.35 in(34mm) from 1 to 127 to function properly. The address is set using DIP _ Diameter:3.93 in(100 mm) switches. Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to SLC or device.Verify the following: 1. Power to the device is removed 2. Field wiring is correctly installed. 3. Field wiring has no open or short circuits. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830108-REVD • 12/18 PAGE 1 OF 2 P POTTER PAD100-PD ® The Symbol of Protection Photoelectric Smoke Sensor Air Velocity Ratings The PAD 100-PD has an Open Area of Protection air velocity rating of 0 to 300 feet per minute. The system has a maximum of 30 LEDs that can be turned on simultaneously.If the system already has 30 LEDs on,the PAD100-PD will operate even though the LED may not illuminate. Operation The PAD100-PD is an analog addressable sensor that uses one address on the Signaling Line Circuit(SLC)of a compatible fire alarm control panel. The unit communicates with the control panel as it is polled The LEDs flash every time the unit is polled and they will flash at a fast rate if the unit is in an active status.The polling LED can be turned off if desired for less conspicuous operation. The PAD100-PD with the PAD100-4DB or PAD100-6DB has a low profile of less than two(2)inches to blend into the surrounding environment.The sensor includes an insect screen to prevent foreign objects from reaching the chamber and the can be cleaned to restore operation of a dirty detector. Sensor Sensitivity The PAD100-PD and the compatible control panel work in tandem to keep the sensitivity consistent.As the sensor is installed over time,the sensor compensates for the dirt in the unit until it is out of range.At that time,the panel will indicate a dirty sensor.The sensor will then have to be cleaned or replaced. The PAD100-PD can be programmed to provide a maintenance alert prior to reaching the dirty sensor level which will allow for intervention prior to the sensor going into trouble. This allows for sensor replacement or cleaning prior to a nuisance trouble occurs. NOTE:As required by NFPA,do not install the sensors until all construction is complete and the work area has been thoroughly cleaned.If the sensors have been installed in a construction environment,they should be cleaned or replaced before the system is placed into service. Spacing The PAD 100-PD is UL listed with a recommended maximum spacing of 30 feet.Refer to NFPA 72 for specific information regarding detector spacing, placement and special applications. Compatible Bases All bases will mount on a single gang,double gang,octagon,4"square or mud ring electrical box. Device Description Stock No. PAD100-4DB 4"Standard Base 3992731 PAD100-6DB 6"Standard Base 3992732 PAD100-1B 6"base with an isolator module included. 3992730 PAD100-RB 6"base with one Form-C relay contact. 2A @ 30VDC,0.5A @ 125VAC 3992728 PAD100-SB 6"base with sounder module included.Sound pattern is provided from external source. 3992729 PAD 100-SPKB 6"base with speaker included 3992762 Ordering Information . Model Description Stock No. PAD100-PD Photoelectric Smoke Sensor 3992733 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830108-REVD • 12/18 PAGE 2 OF 2 PAD100-PSSA/PSDA . P P(')FTER Addressable Pull Station • The Symbol of Protection Single/Dual Action • Features 04011% • Single or Dual Action versions Q� • Durable die-cast construction riat +�' • Reset key matches the fire alarm control panels .. • Compatible with IPA Series panels n(rt Q ff ttpjT r M • SLC Class A,Class X&Class B fl�b '',`a LA" FIRC �H • Product includes a 5 year warranty r,,..••�'"'�� • UUKL Listed for Smoke Control LIFT DOWN & PU�t PALL l (0) APPROVED -11401 Description Technical Specifications The PAD100-PSSA (Single Action) is activated by simply pulling Operating Voltage 24.0 VDC the white "T" bar handle down. The PAD100-PSDA(Dual Action) is activated by lifting the front cover and then pulling the white"T" Max SLC Standby Current 200uA bar handle down.Once activated,the"T"bar cannot be reset without Max SLC Alarm Current 200uA opening the front cover.Opening the front cover will also activate the 32°F-120°F(0°-49°C) pull station.To reset the PAD100-PS Series,use the Potter WS-93 key Environmental Limitations Indoor Only to unlock and open the front cover.Once the cover is open,push the "T°'bar back into the normal position and re-secure the front cover. Dimensions 4.75"H x 3.25"W x 1.75"D Relative Humidity Range 0-93%(non-condensing) Application Single gang box or The PAD100-PSSA/PSDA is compatible with Potter's IPA and AFC/ Mounting Options Potter P32-BB/DBB ARC series addressable fire alarm control panels. It is a non-coded APS-SA-1.22 lbs. addressable pull station available in either a single or dual action Shipping Weight APS-DA 1.46 lbs. model and installs on a single gang box or surface mounts using the P32-BB or P32-DBB(deep)back box. Potter Electric Signal Company, LLC • St. Louis, MO • Phone. 800-325-3936 • www.pottersignal.com 8830097-REVD • 12/18 PAGE 1 OF 2 PAD100-PSSA/PSDA POTTER Addressable Pull Station G The Symbol of Protection Single/Dual Action Setting the Address The PAD100-PS Series uses one SLC address assigned to the device.The address is set using the DIP switch located on the back of the PAD100-PS device. Pull Station Front View Fig 1 711411.11.,400 RP F,R'ED" ., 1 i (Saar« f,_ _'� Km 1 a� FiU_!L J1JLI1J � dd ®Pow '= - PAD100-PSDA PAD100-PSSA Pull Station Back View and Wiring Fig 2 I O 1[IID'ID_ &mist , imi s— ( \1111)`ter - \ FACTORY WIRED CONTACTS FROM FACP OR / , _ _-. al PREVIOUS DEVICE TO NEXT DEVICE II Ordering Information Model Description Stock No. • PAD100-PSSA Addressable Pull Station,Single Action 3992721 PAD100-PSDA Addressable Pull Station,Dual Action 3992720 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 500-325-3936 • www.pottersignal.com 8830097-REVD • 12/18 PAGE 2 OF 2 P PAD100-0R01 ® The Symbol of Protection One Relay One Input Module Features SPANto - • One(1)Class B monitoring input « E • One(1)Form C relay contact i • SLC Class A,Class X&Class B • Mounts in a standard 4"or double gang box • Wiring terminals accessible when mounted in box • All wiring terminals accept 22 to 12 AWGoparrER • Product includes a 5 year warranty "- • UUKL Listed for Smoke Control NOTE:This addressable module does not support 2-wire smoke detectors. ® to) UL APPROVED ll Description Technical Specifications The PAD100-OROI uses one(1)SLC loop address when monitoring Operating Voltage 24.0V one(1)Class B circuit and providing one(1)Form C relay contact. The module mounts on either a 4" square or double gang box. The Max SLC Standby 2401.1A module is capable of monitoring one(1)Class B circuit.The PAD100- Current OROI includes one red LED to indicate the module's status.In normal Max SLC Alarm 240µA condition, the LED flashes when the device is being polled by the Current control panel. When a the input is activated,the LED will flash at a Relay Contacts 2A @30VDC,0.5A @125VAC fast rate. Max Wiring Resistance 100 S2 of IDC Application Max Wiring 1µF ThePAD100-0ROI is compatible with Potter's IPA and AFC/ARC Capacitance of IDC series addressable fire alarm control panels.The PAD100-OROI is an EOL Resistor 5.1K Sl interface module used to monitor dry contact devices such as sprinklerra Temperature 32 to 120°F(4 to 49°C) waterflow, valve tamper switches,or conventional pull stations. The �g module is capable of monitoring one Class B circuit. The PAD100- Operating Humidity 0 to 93%(non-condensing) OROI also provides one(1)form C relay contact. Range Max no.of Module Per 127 units Setting the Address oop Each addressable SEC device must be assigned an address.The 4.17"(106mm)L x 4.17" address is set using the DIP switch located on the PAD100-OROI. Dimensions (106mm)W x 1.14"(29mm)D When the PAD 100-OROI is used to monitor one Class B circuit a single device address is assigned,the input and relay are then Mounting Options Standard 4"Square or Double Gan Box identified as a sub-pointg of the module address.For example,if the address number is assigned as"8",the RLY1 relay will be"8.1"and Shipping Weight 0.6 lbs the 1N1 input will be"8.2". Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to the panel or device: 1. Power to the device is removed. 2. Field wiring is correctly installed. ' 3. Field wiring has no open or short circuits. • Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830081-REVD • 12/18 PAGE 1 OF 2 P POTTER PAD100-0R01 • The Symbol of Protection One Relay One Input Module Installation Using Compatible Electrical Box Fig/ i - --e /4‘ - ' *Ill- I 0 "� �Itlliffil i a ,,4i i _1,c.tcz,__,H,,*.i. _____`,7*-1 losimiamy' i P'. 1 0, 0 '`''''' :• "I" 0 `� Wiring Diagram PADI00-OROI With One Class B Circuit Fig 2 1C2 (: -)� 0 a -g- I 4 awaza L FROMFACPOR \ WWWWWW , PREVIOUS MODULE el •rii -- i�/��1 N6 l +—I Rix, c C') ONE(1)FORM C `"• RELAY CONTACT l - _ +]l �, NC ;] J 0o o I-4PO'fl'E! END-OF-LINE RESISTOR r y $ PAMMOROI 5.1K OHM 1 Part#3005013 FS C-D 0 NOTICE It is possible that the internal relay in the PAD100-OROI may be shipped in the non-normal/activated state.To ensure that the internal relay is set to the normal state,connect the module to the SLC loop and reset the control panel before terminating the wiring to the modules output. Ordering Information Model Description Stock No. PAD 100-OROI One Relay One Input Input Module 3992702 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830081-REVD • 12/18 PAGE 2 OF 2 • �� SYSTEM • SE/VSC�R® IIIltIIlI� FI t I ; Indoor Selectable- 414. V � Output put Horns, Strobes, and Horn Strobes for Wall Applications ,14 k"f System Sensor L-Series audible visible notification products are rich with features guaranteed to cut 1m11, installation times and maximize profits with lower current draw and modern aesthetics. € , Features • Updated Modern Aesthetics The System Sensor 1-Series offers the most versatile and • Small profile devices for Horns and Horn Strobes easy-to-use line of horns,strobes,and horn strobes in the industry • Plug-in design with minimal intrusion into the back box with lower current draws and modern aesthetics.With white and red plastic housings,standard and compact devices,and plain, FIRE, • Tamper-resistant construction and FUEGO-printed devices,System Sensor L-Series can • Automatic selection of 12-or 24-volt operation at 15 and 30 meet virtually any application requirement. candela • Field-selectable candela settings on wall units: The L-Series line of wall-mount horns,strobes,and horn strobes 15,30,75,95, 110, 135,and 185 include a variety of features that increase their application versatility • Horn rated at 88+dBA at 16 volts while simplifying installation.All devices feature plug-in designs • Rotary switch for horn tone and two volume selections with minimal intrusion into the back box,making installations fast and foolproof while virtually eliminating costly and time-consuming • Mounting plate for all standard and all compact wall units ground faults. • Mounting plate shorting spring checks wiring continuity before device installation To further simplify installation and protect devices from construction • Electrically compatible with legacy SpectrAlert and SpectrAlert damage,the L-Series utilizes a universal mounting plate for all Advance devices models with an onboard shorting spring,so installers can test wiring • Compatible with MDL3 sync module continuity before the device is installed. • Strobes and Horn Strobes listed for wall mounting only Installers can also easily adapt devices to a suit a wide range • Horns listed for wall or ceiling use of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings ® 1j LISTED 55512 FM approved except 712:-1653:0504 S4011 for ALERT models 7135-16510503 3057383,3057072 AVDS865-05.2/22/2018•Page 1 • L-Series Specifications Architect/Engineer Specifications General L-Series standard horns,strobes,and horn strobes shall mount to a standard 2 x 4 x 17/8-inch back box,4 x 4 x 11/2-inch back box,4-inch octagon back box,or double-gang back box.L-Series compact products shall mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuit'"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95, 110, 135,and 185. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize Strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1 Operating Voltage Rangel 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6"L x 4.7"W x 1.91"D(143 mm L x 119 mm W x 49 mm D) Compact Wall-Mount Dimensions(including lens) 5.26"L x 3.46"W x 1.91"D(133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.25"D(143 mm L x 119 mm W x 32 mm D) Compact Hom Dimensions 5.25"L x 3.45"W x 1.25"D(133 mm L x 88 mm W x 32 mm D) 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. AV0S865-05.2/22/2018•Page 2 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 88 43 60 Temporal High 39 44 54 Range 30 143 63 83 Temporal Low 28 32 54 75 N/A 107 136 Non-Temporal High 43 47 54 95 N/A 121 155 Non-Temporal Low 29 32 54 110 N/A 148 179 3.1 KHz Temporal High 39 41 54 135 N/A 172 209 3.1 KHz Temporal Low 29 32 54 185 N/A 222 257 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max.Current Draw(mA RMS),Wall Horn Strobe,Candela Range(15-185 cd) 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1K Temporal High 93 156 53 73 119 140 164 190 242 3.1K Temporal Low 91 154 45 66 112 133 160 185 235 3.1K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1K Non-Temporal Low 93 156 52 72 119 138 162 192 242 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1KTemporal High 81 105 155 177 196 234 284 3.1K Temporal Low 68 90 145 166 186 222 276 3.1K Non-Temporal High 104 131 177 204 230 264 326 3.1K Non-Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data Horn and Horn Strobe Output(dBA) 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9* Coded High 85 90 90 10* 3.1 KHz Coded High 84 89 89 *Settings 9 and 10 are not available on 2-wire horn strobes.Temporal coding must be provided by the NAC.ff the NAC voltage is held constant,the horn output remains constantly on. AVDS865-05•2/22/2018•Page 3 L-Series Dimensions 191' .. 3AB' —- �.Q-- 3A6'-�. 985 mm 35mm 125' 327' 1S5' 35 mm 125' 32 mm (LIF cm) (39 em) Y ) 32 mm , = o 52r Addgise. " 5.35' 3 C 1339mm a Tal/ 52'7 (13.7 cm) O G 1111161.21 'III 1339mm .-..1,Jl.F hn— J \P, L°i A0548.00 A0547-00 A0557-00 Compact Strobe,Horn Strobe Compact Horn Compact Wall Surface Mount Back Box SBBGRL,SBBGWL a7o• - (1194cm) _ - 191° (4.55 cm) = 4.7' - 1.25' 49r mm -- n .---.-r=-- - . _. � (M21 cm) 19 c 119mm 1.25" (4.55 m) 21r- 115741) 1 (3.16 mm) 1 KirtE "-o - I= 4111 5.67.. .8. .20.2 •5.67• 1 ( s n C 'M.eecy 3 (14.4cm) 144mn -.n Lt.�. . i_ -1.° -) t, , .7....._,_a_____ Val °O. A0554-01 Strobe,Horn Strobe A05 00 HornWallWall Surface Mount Back Box SBBRUSBBWL L-Series Ordering Information Model Description Model Description Wall Horn Strobes Horns* P2RL 2-Wire,Horn Strobe,Red HRL* Horn,Red P2WL 2-Wire,Horn Strobe,White HWL* Horn,White P2GRL 2-Wire,Compact Horn Strobe,Red HGRL* Compact Horn,Red P2GWL 2-Wire,Comp 2 fits act Horn Strobe,White HGWL* Compact Horn,White P2RL-P 2-Wire,Horn Strobe,Red,Plain Accessories P2WL-P 2-Wire,Horn Strobe,White,Plain TR-2 Universal Wall Trim Ring Red P2RL-SP 2-Wire, Horn Strobe,Red, FUEGO TR-2W Universal Wall Trim Ring White P2WL-SP 2-Wire,Horn Strobe,White,FUEGO SBBRL Wall Surface Mount Back Box,Red P4RL 4-Wire,Horn Strobe,Red SBBWL Wall Surface Mount Back Box,White P4WL 4-Wire,Horn Strobe,White SBBGRL Compact Wall Surface Mount Back Box,Red Wall Strobes SBBGWL Compact Wall Surface Mount Back Box,White SRL Strobe, Red SWL Strobe,White SGRL Compact Strobe,Red SGWL Compact Strobe,White SRL-P Strobe,Red,Plain SWL-P Strobe,White,Plain SRL-SP Strobe,Red,FUEGO SWL-CLR-ALERT Strobe,White,ALERT Notes: All-P models have a plain housing(no"FIRE'marking on cover). All-SP models have"FUEGO'marking on cover. All-ALERT models have"ALERT"marking on cover. *Horn-only models are listed for wall or ceiling use. • f' 3c)r777314 3825 Ohio Avenue•St.Charles, IL 60174 02018 System sensor. SENSOR® Phone:800-SENSOR2•Fax:630-377-6495 oductsped9ca5mssubject to change without no5ce.Visit systemsensor.com for Gwent product information,indudmg the latest version of this data sheet Y www.systemsensor.com AVDS865-05.222/2018 . : ..) SYSTEM = .' ; .,. �,,$ SENS • a. , it: ' �.'° Indoor Selectable- Output Strobes and £ -� 44,--<4,4_ry Horn Strobes for 0. :-:-7_ Ceiling Applications System Sensor L-Series audible visible notification .. . products are rich with features guaranteed to cut installation times and maximize profits with lower , r current draw and modern aesthetics. 41 Features The System Sensor L-Series offers the most versatile and • Plug-in design with minimal intrusion into the back box easy-to-use line of horns,strobes,and horn strobes in the industry with lower current draws and modern aesthetics.With white and red • Tamper-resistant construction plastic housings,wall and ceiling mounting options,System Sensor • Automatic selection of 12-or 24-volt operation L-Series can meet virtually any application requirement. at 15 and 30 candela • Field-selectable candela settings on ceiling units: The entire L-Series product line of ceiling-mount strobes and horn 15,30,75,95, 115, 150,and 177 strobes include a variety of features that increase their application versatility while simplifying installation.All devices feature a plug-in • Horn rated at 88+dBA at 16 volts design with minimal intrusion into the back box,making installations • Rotary switch for horn tone and two volume selections fast and foolproof while virtually eliminating costly and time- consuming ground faults. • Universal mounting plate for ceiling units • Mounting plate shorting spring feature checks wiring continuity To further simplify installation,the L-Series utilizes a universal before device installation mounting plate so installers can mount them to a wide array of back • Electrically Compatible with legacy SpectrAlert and SpectrAlert boxes.With an onboard shorting spring,instatters can test wiring Advance devices continuity before the device is installed. • Compatible with MDL3 sync module Installers can also easily adapt devices to a suit a wide range of • Listed for ceiling mounting only application requirements using field-selectable candela settings, mil automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING ® v T LISTEDAP u"W'd 55512 FM approved except 712;-16520564 • 54011 for ALERT rmdets 7135-16520503 3057383 AVDS868-02.12/0112017•Page 3 • L-Series Specifications Architect/Engineer Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11 -inch back box,4-inch octagon back box,or double- gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuit°'Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95, 115, 150,and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Rangel 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range(MDL3) 8.5 to 17.5V(12 V nominal)or 16.5 to 33 V(24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6.8'diameter x 2.5'high(173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9'diameter x 3.4'high(175 mm diameter x 86 mm high) (SBBCRL,SBBCWL) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDS868-02.12/01/2017•Page 2 • UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 87 41 60 Temporal High 39 44 54 Range 30 153 63 86 Temporal Low 28 32 54 75 N/A 111 142 Non-Temporal High 43 47 54 95 N/A 134 164 Non-Temporal Low 29 32 54 115 N/A 158 191 3.1 KHz Temporal High 39 41 54 150 N/A 189 228 3.1 KHz Temporal Low 29 32 54 177 N/A 226 264 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max.Current Draw(mA RMS),Ceiling Horn Strobe,Candela Range(15-177 cd) 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1K Temporal High 111 164 69 94 147 163 184 229 257 3.1K Temporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1K Temporal High 108 135 179 200 225 255 289 3.1K Temporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data Horn Strobe Output(dBA) 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 AVD3868-02.12/01/2017•Page 3 'L-Series Dimensions 2.47"(62.7 mm) 1.37'(34.8 mm) - 6.92"diam. 2.5" --.- 6.83"diam.—\ (175.77 mm) (64 mm) (173 mm) 6-- (c ) O O`' -- o O 80008 J A054500 A0546-00 Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box ®44. (A' ®48 / �.� O fs, off D ' 1 ,5�illi, yl� �' ` r���� aert�1 "..\\ I �," tsj �f fifieIMHt \ 0. kepi 1 1111111t 1 ii s .1-4!-1,1-1- .7,/,e!r'.,, I c.2 , Atij(4,40. ,,,. ...___, °---. ,-nr>-;.,, ,,,nn ::,--,;,--. -..ne 0' Wyg _. H:- --—':'. . 3 \ y `��i \ * � ,' YA0494-01 . — A0531-01 2-Wire Ceiling Mount Horn Strobes 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box with Ceiling Surface Mount Back Box L-Series Ordering Information Model Description Model Description Ceiling Horn Strobes Ceiling Strobes PC2RL 2-Wire,Horn Strobe,Red SCR.. Strobe,Red PC2WL 2-Wire, Horn Strobe,White SCWL Strobe,White PC4RL 4-Wire,Horn Strobe,Red SCWL-CLR-ALERT Strobe,White,ALERT PC4WL 4-Wire,Horn Strobe,White Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box,Red SBBCWL Ceiling Surface Mount Back Box,White For a ceiling-listed horn-only device,see AVDS865"Indoor Selectable- Output Horns,Strobes,and Horn Strobes for Wall Applications". * 45/$4577Ehl ©2017 System Sensor. � � �� 3825 Ohio Avenue•St. Charles, IL 60174 Productspecilicalionssubjecttochangewimoutrrooce.Visit systemsensocoom 1.r Phone:800-SENSOR2•Fax:630-377-6495 for current product information,including the latest version of this data sheeL AVDS868-02•12/01/2017 SYSTEM \,_V SENSOR® Outdoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications SPECTFIert SpectrAlert®Advance outdoor audible visible products to ® "di' "' c E are rich with features that cut installation times and maximize profits. Features SpectrAlert Advance offers the broadest line of outdoor horns, • • Weatherproof per NEMA 4X, IP56 strobes,and horn strobes in the industry.With white or red plastic housings,wall or ceiling mounting options,and plain or FIRE-printed • Listed to UL 1638(strobe)and UL 464(horn) devices,SpectrAlert Advance can meet virtually any application • Compatible with System Sensor synchronization protocol and requirement,including indoor,outdoor,wet,and dry applications in legacy SpectrAlert products temperatures from-40°F to 151°F. • Field-selectable candela settings: 15,15/75,30,75,95, 110, 115, 135,150, 177,and 185 Like the entire SpectrAlert Advance line,outdoor horns,strobes, and horn strobes for wall applications include a variety of features • Automatic selection of 12-or 24-volt operation at 15 and that increase application flexibility and simplify installation. First, 15/75 candela field-selectable settings,including candela,automatic selection of • Rotary switch for horn tone and three volume selections 12-or 24-volt operation,horn tones,and three volume options enable installers to easily adapt devices to meet requirements. • Horn rated at 88+dBA at 16 volts • Rated from-40°F to 151°F Next,SpectrAlert Advance devices use a universal mounting plate • Universal mounting plate with an onboard shorting spring that for both wall and ceiling applications.This mounting plate includes tests wiring continuity before devices are installed an onboard shorting spring that ensures wiring continuity before • Plug-in design with minimal intrusion into the back box devices are installed,so installers can verify proper wiring without mounting the devices and exposing them to potential construction • Tamper-resistant construction -- damage.Once the plates are mounted,all SpectrAlert Advance • Listed for ceiling or wall mounting devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes(metal back boxes are available separately)that accommodate in-and- Agency Listings out wiring for daisy chaining devices.Plastic back boxes feature removable side flanges and improved resistance to saltwater SWAMcorrosion.Knock-outs located on the back eliminate the need to drill tO U � holes for screw-in mounting.Plastic and metal weatherproof back ° MEA lel boxes come with 3/4-inch top and bottom conduit entries and 34-inch �r�/'� 730P4653:188(outdoor strobes) 7,25-1653:,88(horn so-°bas, knock-outs at the back.A screw-in NPT plugwith an 0-ringgasket S4011(chimes,horn strobes,horns) •wnoveo approved chime strobes) 33593(outdoor and alert strobes) 3023572 Men452-05-E 7136:1653:189(horns,chimes) for a watertight seal is included with each back box. • SpectrAlert Advance Outdoor Horn, Strobe,and Horn Strobe Specifications Architect/Engineer Specifications General SpectrAlert Advance outdoor horns,strobes,and horn strobes shall mount to a weatherproof back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products,when used with the Sync•Circuit'°Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts.Outdoor SpectrAlert Advance products shall operate between-40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30,75,95, 110, 115,135, 150,177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL.The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options shall be set by a multiple position switch. On four-wire products,the strobe shall be powered independently of the sounder.The horn or horn strobe models shall operate on a coded or non-coded power supply.The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Physical/Electrical Specifications Operating Temperature -40°F to 151°F(-40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Rangel 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6"L x 4.7"W x 2.5"D(142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.3"D(142 mm L x 119 mm W x 33 mm D) Wall-Mount Weatherproof Back Box Dimensions(SA-WBB) 5.71_x 5.1"W x 2.0"D(145 mm L x 130 mm W x 51 mm D) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS01201 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR • Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-Temporal High 57 56 69 75 95 NA NA 181 176 Non-Temporal Medium 42 50 60 69 110 NA NA 202 195 Non-Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Standard Candela Range(15-115 cd) 8-175 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 • Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,High Candela Range(135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures,listed Horn and Horn Strobe Output(dBA),, candela ratings must be reduced in accordance with 8-17.5 16-33 24 Volt Nominal this table. Strobe Output(cd) Switch Sound Volts Volts Reverberant Anechoic Position Pattern dB DC FWR DC FWR DC FWR DC FWR Listed Candela Candela rating at-40°F 1 Temporal High 78 78 84 84 88 88 99 98 15 2 Temporal Medium 74 74 80 80 86 86 96 96 15/75 Do not use below 32°F 3 Temporal Low 71 73 76 76 83 80 94 89 30 4 Non- High 75 44 Temporal 82 82 88 88 93 92 100 100 95 70 5 Non- Medium 110 110 Temporal 78 78 85 85 90 90 98 98 115 115 6 Non- Low 75 75 81 81 88 84 96 92 135 135 Temporal 150 150 7t Coded High 82 82 88 88 93 92 101 101 • 177 177 8t Coded Medium 78 78 85 85 90 90 97 98 185 185 91 Coded Low 75 75 81 81 88 85 96 92 tSettings 7, 8,and 9 are not available on 2-wire horn strobe. Au0S01201 • SpectrAlert Advance Diagrams II 4.7" 1 2.5=10 Al `�`` 1.1 t 5.6" NM �� � �� � lICAIIIL - l 101='; Wall-Mount Horn Strobes ��E-�..,v.- Wall Plastic Weatherproof Back Box 111'11 III-- iii . ''', Ill r . - ml li . i ' to" • 1. 11 '�1 r1i 1.;....r"."-a yii =! „II 1�.0w _ 4 Wall-Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information Model Description Wall Horn Strobes P2RK*1 2-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) P2RHK*t 2-Wire Horn Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) P2WK*t 2-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2WHK*t 2-Wire Horn Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) P4RKt 4-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe,High cd,Red,Outdoor, 120 V(includes plastic weatherproof back box) Wall Strobes SRK*t Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) SRHK*t Strobe, High cd,Red,Outdoor(includes plastic weatherproof back box) SWK*t Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) SWHK*t Strobe, High cd,White,Outdoor(includes plastic weatherproof back box) Horns HRKt Horn,Red,Outdoor(includes plastic weatherproof back box) Accessories SA-WBB Red,Metal Weatherproof Back Box SA-WBBW White,Metal Weatherproof Back Box Notes: *Add"-P"to model number for plain housing(no"FIRE"marking on cover),e.g.,P2RK-P. t Add"-R'to model number for weatherproof replacement device(no back box included),only for use with weatherproof outdoor flush mounting plate,WTP and WTPW. " "Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings."High cd"refers to strobes that include 135,150,177,and 185 .. candela settings.When replacing e standaM outdoor units both the device and back box must be replaced. SYSTEM ©2072 System Sensor. `'�� �� ® 3825 Ohio Avenue•St.Charles, IL 60174 Productapecilicatonssubjectt>changewitoutnotice.Visitsystemsensoccom Phone:800-SENSOR2•Fax:630-377-6495 to current product intro-orlon,including the latest ver4on of this data sheet AVDS01201•3/12 SRD ACE-11 Ac ox System Record Documents f BY SPACE AGE ELECTRONICS Store important system documents in a secure location with a cabinet built specifically to meet the SYSTEM RECORD requirements of NFPA 72 7.7.2.4. DOCUMENTS The number one goal at Space Age is to manufacture code •- • compliant solutions, and the SRD is just that. NFPA 72 7.7.2.1 states, "With every new system, a documentation cabinet shall be installed at the system control unit or other approved location at the protected premises." The SRD includes our innovative 8GB flash drive slide tab that allows the user to select a USB-C or Micro USB connector to access records electronically(See NFPA 72 7.5.6.7). UWNto FEATURES pcVel usp • 18 gauge cold rolled steel SPECIFICATIONS SAN E�� IONS construction with red powder coat and white The SRD System Record Documents Box shall be UL Listed, lettering constructed of 18 gauge cold rolled steel. It shall have a UL • Dimensions are 12" wide x powder coat finish. The cover shall be permanently screed with 1" high lettering "SYSTEM RECORD DOCUMENTS"with white 13"tall and 2 1/4" deep LISTED • indelible ink.The access door shall be locked with a 3/4" barrel • Stainless steel piano hinge lock and there will be a 12"stainless steel piano hinge. The SRD • Two key ring hooks to hold will have a minimum of 8 gigabyte digital flash memory drive CAL system keys with a slide tab that allows user to select USB-C or Micro USB FUZE connector for uploading and downloading information. The + Business card holder for key enclosure will supply 4 mounting holes. Inside will contacts accommodate standard 8 1/2"x 11" manuals and document • Slide tab allows user to records.A legend sheet will be attached to the door for system select USB-C or Micro USB required documentation, key contacts and system information. connector to download The enclosure shall also provide 2 key ring holders with a from 8GB digital flash location to mount standard business cards for key contact memory personnel. CUSTOM COLORS AND BRANDING AVAILABLE YO R • • YOURS YOUR YOUR, #xf L O LOGO LQOQ{ '' LOGO'' LQG0 Pg.1/2 AetOX Z OX DIMENSIONS 2.35 -1---- r 1 12.00 _. .75----- 1 1.63pi_ j A tt �► OMEN RECORD 9.75 12:39 13.00 13.16 • 1.63 0.25 11.76 _ ORDERING INFORMATION P/N#SSU00689 System Record Documents Cabinet- Red P/N#SS000690 System Record Documents Cabinet- Red with your custom screened logo P/N#SSU01689 System Record Documents Cabinet- Black P/N#SSU01690 System Record Documents Cabinet- Black with your custom screened logo www.isae.com I toll free 1.800.4861723 I fax 508.485.4740 n t ©Copyright 2018 Space Age Electronics,Inc.I This document subject to change without notice I LT10641 I Rev.D Nnwar` Pg.2/2