Loading...
Plans (75) P-SERIES SUBMITTAL DATA: PKA-A24KA7 & PUY-A24NHA7(-BS) ' MITSUBISHI 24,000 BTU/H WALL-MOUNTED AIR-CONDITIONING SYSTEM /_ELECTRIC Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PKA-A24KA7 o PUY-A24NHA7 o PUY-A24NHA7-BS 444, 7;1iI IIIllillllIOOIIPIIIIliL` IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII11, IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII 11111111111111111110011111111111111111111111hIpIIIIIII10IIIIIIIIIilllh! k_n "IJIAllliilpJIIP" .1 • INDOOR UNIT FEATURES • Sleek,compact design • Simple installation • Vane setting for air flow direction control • Auto fan speed mode • Ideal for spaces such as server rooms,daycare centers,classrooms,churches,small offices,and more OUTDOOR UNIT FEATURES • Variable speed INVERTER-driven compressor • Suction accumulator pre-charged with refrigerant volume for piping length up to 100 ft(70 ft.for Al2/18/24/30) • Low ambient cooling down to-20°F providing 100%capacity(only for PUY models with wind baffles installed) • 24-hour continuous operation(cooling mode) • High pressure protection • Fast restart due to bypass valve make it ideal for equipment cooling applications,such as data centers • Superior energy and operational efficiency Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. R _,',. SPECIFICATIONS: PKA-A24KA7 & PUY-A24NHA7(-BS) Indoor Unit PKA-A24KA7 Model Number PUY-A24NHA7 Outdoor Unit PUY-A24NHA7-BS _-_ Maximum Capacity Btu/h RE 7,'. 24000 Rated Capacity Btu/h 1 24,000 1 Minimum Capacity Btu/h SEP 0 2019 10,000 Maximum Power Input W -)-orf c F. '1 '' ,960 Cooling C Rated Power Input W BU WINO ti Ur,. -`�1`,660 Moisture Removal Pints/h 5.0 Sensible Heat Factor 0.77 Power Factor % 95.7 SEER 21.4 Efficiency EER1 12.2 Voltage,Phase,Frequency 208/230V, 1-phase,60 Hz Guaranteed Voltage Range V AC 198 253 Voltage:Indoor-Outdoor,S1-S2 V AC 208/230 Electrical Voltage:Indoor-Outdoor,S2-S3 V DC 24 Voltage:Indoor-Remote controller V DC 12 Recommended Fuse/Breaker Size A 25 Recommended Wire Size(Indoor-Outdoor) AWG 14 MCA A 1 Fan Motor Full Load Amperage A 0.36 Fan Motor Output W 56 Airflow Rate,Dry CFM 635-705-775 Airflow Rate,Wet CFM 570-635-700 External Static Pressure in.WG n/a Sound Pressure Level dB(A) 39-42-45 Drain Pipe Size In.(mm) 5/8(16) Condensate Lift Mechanism,Max.Distance In.(mm) n/a Indoor Unit _ Heat Exchanger Type Plate fin coil External Finish Color White Munsell 1.0Y 9.2/0.2 W:In.(mm) 46-1/16(1170) Unit Dimensions D:lh.(mmc 1T- (ii t H:In.(mm) 14-3/8(365) W:In. 51 Package Dimensions D:In. 18-8/16 H:In. 14-4/16 Unit Weight Lbs.(kg) 46(21) Package Weight Lbs. • 53 Indoor Unit Operating Cooling Intake Air Temp(Maximum/Minimum) °F 90 DB,73 WB/66 DB,59 WB Temperature range Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. • SPECIFICATIONS: PKA-A24KA7 & PUY-A24NHA7(-BS) Indoor Unit PKA-A24KA7 Model Number PUY-A24NHA7 Outdoor Unit PUY-A24NHA7-BS MCA A 19 MOCP A 26 Fan Motor Full Load Amperage A 0.40 Fan Motor Output W 86 Airflow Rate CFM 1,940 Refrigerant Control Electronic Expansion Valve Heat Exchanger Type Cross fin Sound Pressure Level,Cooling1 dB(A) 47 Compressor Type INVERTER-driven twin rotary Compressor Model SNB 172FWH M 1 ....------------- Compressor Rated Load Amps A 7 Outdoor Unit Compressor Locked Rotor Amps A 11 Compressor Oil Type//Charge oz. FV5OS//23 External Finish Color Ivory Munsell 3Y 7.8/1.1 Base Pan Heater n/a W:In.(mm) 37-13/32(950) Unit Dimensions D:In.(mm) 13+1-3/16(330+30) H:In.(mm) 37-1/8(943) W:In. 40-15/16 Package Dimensions D:In. 17-11/16 H:In. 40-11/16 Unit Weight Lbs.(kg) 151 (68) Package Weight Lbs.(kg) 176(80) Outdoor Unit Operating Cooling Intake Air Temp(Maximum/Minimum) °F 115 DB/-20*DB Temperature Range Type R410A Refrigerant — Charge Lbs,oz 7 lbs, 11 oz Gas Pipe Size O.D.(Flat ) in.(mm)•— -.54#16.88)__ Liquid Pipe Size O.D.(Flared) In.(mm) 3/8(9.52) Piping Maximum Piping Length Ft.(m) 225(69) Maximum Height Difference Ft.(m) 100(30) Maximum Number of Bends 15 Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. SPECIFICATIONS: PKA-A24KA7 & PUY-A24NHA7(-BS) • Notes AHRI Rated Conditions(Rated data is (1Cooling(Indoor//Outdoor) °F 80 DB,67 WB//95 DB,75 WB determined at a fixed compressor speed) 1 . *Wind baffles required to operate below 23°F DB in cooling mode.PUY with wind baffle:-20°F-115°F.Refer to wind baffle documentation for further • information. **System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. SEACOAST PROTECTION • External Outer Panel:Phosphate coating+Acrylic-Enamel coating • Fan Motor Support: Epoxy resin coating(at edge face) • Separator Assembly;Valve Bed:Epoxy resin coating(at edge face) • "Blue Fin"treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants. Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. r ACCESSORIES: PKA-A24KA7 Signal Receiver ❑PAR-SA9CA-E Wireless Remote Controller ❑PAR-FL32MA-E Wireless Remote Receiver ❑PAR-FA32MA-E Backlit,Wall-mounted,Wireless Controller ❑MHK1 Portable Central Controller o MCCH1 Wired MA Controller ❑PAR-33MAA Simple MA Controller ❑PAC-YT53CRAU Touch MA Controller ❑PAR-CT01 MAU-SB Wired Remote Sensor o PAC-SE41TS-E Lockdown Bracket for Wireless,Hand-held,Remote Controller ❑RCMKPICB Wireless Temperature and Humidity Sensor ❑PAC-USWHS003-TH-1 Outside Air Sensor for MHK1 o MOS1 Flush Mount Remote Temperature Sensor o PAC-USSEN001-FM-1 Wireless Interface ❑PAC-USWHS002-WF-1 Thermostat Interface o PAC-US444CN-1 kumo station® o PAC-WHS01 HC-E USNAP Interface o PAC-WHSO1UP-E IT Extender o PAC-WHS01lE-E BACnet®and Modbus Interface ❑PAC-UKPRC001-CN-1 Connector for CN32(remote on/off) ❑PAC-SE55RA-E External Drain Pump ❑PAC-KEO7DM-E External Drain Pump o PAC-SH94DM-E Blue Diamond Sensor Extension Cable-15 Ft. ❑C13-103 Mini Condensate Pump-230V application o SI30-230 MegaBlue Advanced Blue Diamond Condensate Pump w/Reservoir&Sensor o X87-835-110 to 250V MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/Reservoir&Sensor(208/230V)up to 48,000 Btu/h o X87-721-208/230V [recommended] Drain Pan Level Sensor(Control for indoor unit shut off to prevent drain pan overflow) 0 DPLS2 3 Pole Disconnect Switch(30A/600VUL)[fits 2"X4"utility]-Black ❑TAZ-MS303 3 Pole Disconnect Switch(30A/600VUL)[fits 2"X4"utility]-White ❑TAZ-MS303W Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. ACCESSORIES: PUY-A24NHA7(-BS) Twinning Distribution Pipe(50:50) o MSDD-50TR-E Air Outlet Guide ❑PAC-SG59SG-E Front Wind Baffle o WB-PA5 Drain Socket o PAC-SG61 DS-E Centralized Drain Pan o PAC-SG64DP-E M-NET Converter o PAC-SF83MA-E M-NET Converter o PAC-SJ95MA-E Control/Service Tool ❑PAC-SK52ST Hail Guard ❑HG-A6 Condensing Unit Mounting Pad 24"x 42"x 3" o ULTRILITE2 Outdoor Unit Stand-12"High ❑QSMS1201 M Outdoor Unit Stand-18"High o QSMS1801 M Outdoor Unit Stand-24"High o QSMS2401 M Heavy Duty Wall Mounting Bracket for Outdoor Units—Coated Steel o QSWB2000M-1 Heavy Duty Wall Mounting Bracket for Outdoor Units-316 Series Stainless Steel o QSWBSS 3/8"x 5/8"x 10'/1/2"Lineset(Twin-Tube Insulation) o MPLS385812T 10 3/8"x 5/8"x 15'/1/2"Lineset(Twin-Tube Insulation) ❑MPLS385812T-15 3/8"x 5/8"x 30'/1/2"Lineset(Twin-Tube Insulation) ❑MPLS385812T-30 3/8"x 5/8"x 50'/1/2"Lineset(Twin-Tube Insulation) o MPLS385812T-50 3/8"x 5/8"x 65'/1/2"Lineset(Twin-Tube Insulation) o MPLS385812T-65 3/8"x 5/8"x 100'/1/2"Lineset(Twin-Tube Insulation) o MPLS385812T-100 ®_ .... Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. .r DIMENSIONS.. PKA-A24KA7 & PUY-A24NHA7 (-BS) PKA-A24KA7 Unit: inch (mm) -P 1&11/16423.7 11143,.1; a mI _ - v Len side ff Front L.,',. i M°en no.rd 1a� re ilpli o • 2-29/32(]4) 3.1-21/32851,60,,o) 1. 9-112(241) 3/16(5) A FroneMe(Gdle open) operation lorty Knock.ho4o for rgh piping f 1 1 1 I 1 2 -__ r( DEFROSTISTPND 8Y lampceivor nNm - _ NIP �: \Terminal block forOWooupplTerminal block for power wunit(option) N _ Ta'V:1 for1,11 — — �—_ ama.wno-aear"gCt . r.uer ho:). ,IN reoeliwhe.yalaPegj newlrch in 13/16 0 --------- - ■I 13re 5 train hoses 17-15132(444)Gan pipe © 4-27/22(123) Oil 2-19132 86 1631/32(462)Lquid owe (1(_ 64/16(154) 58/22(134) Under side 7 ■I ONOM,aitair��--Y Piping connection 11 vBAe B1"0 "'"°'n1d",.' / \ S Liquid pipe Flared cont pipe: 8 0.D(09.52) B / e Flared connection:3/8F Knockout hole Sleeve Wally) lower Fong Refrigerant pipe:5/80.D(015.88) (purchased Through hole .2 Gas pipe Flared connection:5/8F 02-15116 ((05500 X35/32 (>d75 30 Drain hose 5/8(016)O.D ) Effective length:23-1/32(585) Required apecegndoor une) III Air inlet 1�%' Knockout holo for piping !, 6 ro �A PI 'F' "l r 411 1 . iii :lo Y C __� �-III m Air outlet , o = En , E Min.9-21/32220 Mr 15.331/32100.5 � Pl 11111 29/1.65 III 31/321771 II=1 2SI16 66 ilill 17/16(67) Min.2.1/16 52.3) dr 1352(10,7) i Center measuremert hole 0352 0_5 o n a-@„I3z1q.5)900 sol. .6g a a " aemfi c Ai93ag La:"w :.1/ f,RS' ;5 } € 0 a / /1,:tll Indoor lM outline ri I afl l---I�. ='sa 'apg.i— tai ■ ci.la 061 II I-s,naw r--1�� a �a—.11E, ill ,r-nz6) 215,164751 7•pi111��x155216251 /01641°0 raw a .. =n.1 a]61875) 4,A f6 5) /r r- 7O7i� 2D2e51 ,a'3b I4^.�J!• L� Kfi Ar1 64,6]1 • • :;;Z:22'n127e5 _ __ � _.�.� :vel_.►___;Imam/ /1.1/2232 ■bia11■■rrl�ri�.111r■1111ir�1 100 1/6) A R 5 2z ' - n hole M rear piping wall bole. Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. F DIMENSIONS: PKA-A24KA7 & PUY-A24NHA7 (-BS) PUY-A24NHA7(-BS) Unit:mm<in> 1 FREE SPACE(Around the unit) 2 SERVICE SPACE 3 FOUNDATION BOLTS 4 PIPING-WRING DIRECTIONS nn The dagram below shows a Dimension of space needed Please secure the unit firmly Pi' and wiring connections �RearMlydalre ed hole6 basic example. for service access are with 4foundation 10MLY8>baps. can�be made from 4 directions: (tamhapenB MIO<W Ex antion of particular details are shown in the below diagram. (s I (saunehtion Boa M1aW31a>) a pa (Bolts and washers must be FRDNT,RgM,Rear and Below. ,16,6)/60 60o«34/8> 76<6.78> given in the installation manuals etc. purchased locally.) • B � I"'— ,Foundation bolt height „ ////�iwiti Side,.A�iJr lyd�ajke n�IIMIII =��( 110<13> re • ✓ m g 8 FOUNDATION/ I� R Ser•vice g8 .� 4.. -..i MkaIn. .g u )a<2.9/ 500,18-11/160 l�L, Crj d ry Air Discharge V x�F_1;.=:::,,,,,,- . "a,<,ya> ( mo/ g§ (Foun oon Bolt c�X 242.36 42m6oval aM1o<K3/®) o Terminal Connections Left-Power wpppplIy vnring 11 • Handle e50<37-131320 Reight--IndoorlOutdoor wnng/ RearAir Intake for movi , 2202-11/16 Earth terminal /Side Airintake 3 L Service panel ndle for for mol dna ''',•;•- - -.---Z ` /Handle for moving Example of Notesmoving 1 ®....... l� I ...Re dgenm GAS p pe onne on FARE) e15.69(5eF( —=, I i 1, I 2.-.ReldgenmLIQUIDpipeconnecson(FLARE).9.52(308F( r • yy 0 '1•••Indicpaon of STOP VALVE connection location. A '"�.rI l I —vr ._•`I A e ;: o Air lntake� ���� �� I -0000. e. . h—L ' Front pjpina cover 1/- • 1,<2.rwrs< Rear piping cover Piping knockout Hole Details Power supphwinghole Sate aeachmentbd tp iii ■ V-atlmoc Whenaotalingtecondui �� Powersi wiing hole Righs ling hole eking hole Parer supplyinnerside ofee<n Ds amun.mormem Y� 7a27knoFroMemkirg hoe o�,ans> ,s<i.r✓3z> ,x,zaa aa,ans>2-a27<t9noskoW Boeom piping hoe (knockout @ 1s< ,n ao<,_w,e> @- RearWnN Iwk z-nz<1,e> liku 177-jj �. n,. II 2hti v a k_ • `x /M• 40,4116>1 2 Front toe r ' "�`�s> r',0 : Ren png hoe V _,,IIPIRRIMII-;•;Sa¢�5/160) (lent rtt , L (knc�Outl • 63,26,160 r '1� « F3 • • • Apr.% MITSUBISHI ELECTRIC COOLING & HEATING 1340 Satellite Boulevard,Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com Aa9 CERTIFIED caus FORM#PKA-A24KA7/PUY-A24NHA7(-BS)-201810 Intertek Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC.All rights reserved.