Plans (21) CONTENTS WILLIAMS RESIDENCE RECEIVED SHEET# SHEET NAME �� _ JUL 2 5 2019 T-1 TITLE SHEET. PHOTOVOLTAIC SYSTEM PROJECT - CITY �YOGo�sRD PV-1 SITE—MAP. ON E-1 ELECTRICAL ONE—LINE. 7 . 13 kVV S-1 STRUCTURAL MOUNTING. DC , 1 OR'ICE OWNER: Vance &Wendy Williams LIABILITY ADDRESS: 12070 SW Whistlers Loop, Tigard, OR 97223 PHONE: 503-347-3308 The City of Tigard and its Approved plans E-MAIL: vanceleewilliams@gmail.com employees shall not be UTILITY PROVIDER: PGE shall be on lob site. UTILITY ACCOUNT#: 5901660000 responsible for discrepancies SOLAR MODULES: SLA-M 310 which may appear herein. INVERTER: SE 7600H-US RACKING: Roof Mount Snap N Rack • CITY OF TIGARD VALIDITY OF PERMITREVIEWED FOR C DE COMPLIANCE THE ISSUANCE OF A PERMIT Approved: I BASED ON CONSTRUCTION OTC: I I DOCUMENTS AND OTHER Permit#: yy,ST I9 ' 001f) DATA SHALL NOT PREVENT THE CODE OFFICIAL FROM Address; l2_()--7bS`t33 W S\ Loop REQUIRING THE CORRECTION Suite #: -- OF ERRORS.ORSC 105.4 B}: Date: --772.V(43 GENERAL NOTES 1.ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE LATEST OR CODE OF REGULATIONS, NATIONAL 2.ALL PANELS, SWITCHES, ETC. SHALL HAVE SUFFICIENT GUTTER SPACE AND LUGS IN COMPLIANCE TO UL REQUIREMENTS TO ACCOMMODATE CONDUCTORS SHOWN. 3. WHERE WIRE SIZES ARE INDICATED ON PLANS, FOR INDIVIDUAL CIRCUITS, THE WIRE SIZE INDICATED SHALL APPLY TO THE COMPLETE CIRCUIT, UNLESS OTHERWISE NOTED. 4. CONTRACTOR SHALL EXTEND WIRING FROM ALL JUNCTION BOXES, SWITCHES, ETC.AND MAKE FINAL CONNECTION AS REQUIRED TO ALL BUILDING EQUIPMENT REQUIRING ELECTRICAL CONNECTIONS. 5. DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT OF SYSTEMS AND WORK INCLUDED. FOLLOW DRAWING IN LAYING OUT WORK AND CHECK DRAWINGS OR OTHER TRADES RELATING TO WORK TO VERIFY SPACE IN WHICH WORK WILL BE INSTALLED. MAINTAIN HEADROOM AND MINIMUM CODE REQUIRED WORKING CLEARANCES AT ALL TIMES. 6.ALL EXTERIOR ELECTRICAL DEVICES AND EQUIPMENT INCLUDING THOSE THAT ARE EXPOSED TO OUTSIDE ENVIRONMENT SHALL BE WEATHERPROOF TYPE, NEMA 3R. 7. DISCONNECT SWITCHES SHALL BE MOUNTED ON INDIVIDUAL SUPPORTS, OR OTHERWISE DIRECTLY ON EQUIPMENT, PROVIDED. 8. NO MODIFICATION TO EQUIPMENT IS NECESSARY.ALL ELECTRIC MATERIAL SHALL BE LISTED BY"UL" FOR THE TYPE OF APPLICATION AND "UL" LABEL SHALL APPEAR ON ALL ELECTRICAL EQUIPMENT. 9. WIRING METHOD SHALL BE EMT ABOVE GROUND AND MOUNTED IN CONCEALED SPACES (UNLESS APPROVED OTHERWISE)AND SCHEDULE-40 PVC FOR BELOW GROUND INSTALLATION UNLESS NOTED OTHERWISE. PHOTOVOLTAIC SYSTEM GREEN RIDGE POWER WILLIAMS 5/31/18 AATITLE PAGE 12070 SW Whistlers Loop GREEN RIDGE PO4YEP, DESIGN Tigard, OR 97223 SCALE: C Designed by Erik Duff Notes: 1.This system meets the requirements of NEC 690.35 and is 7.Local utility provider shall be notified prior to use and exempt from the system grounding requirements of NEC activation of any solar photovoltaic installation. 690.41 System Grounding. 8.No sheet metal or tech screws shall be used to ground 2.The DC conductors are not bonded to ground and the disconnect enclosure with tin-plated aluminum lugs;proper MAX MAIN O.C.PMPACITY CALCS optimizers do not require a GEC. grounding/bar kits must be used. see ssosa(s)(z)of zola NECNec 3.NEC 690.43(C)Structure as Equipment Grounding 9.All solar modules,equipment,and metallic components Main Breaker=200A`(1.20)=240A Max Main Bus Rating Conductor allows forequipment to be used as the EGC in are to begrounded in accordance with code and the WIRE AMPACITY THERMAL OER4TE FACTOR NUMBER OF CONDUCTORS Max PV Breaker 2017 NEC 310.15(8)(16) 2014 NEC 310.15(8)(2)(a) 2014 NEC 310.1593)(3)(a) a photovoltaic system. manufacturer's installation instructions. Design Breaker size=40A 210 IIWN-2 31°35°C+22°C (4-6)MAX. 4.The devices listed and identified for grounding the 10.PV modules Cannot be installed over or block any attic 90° equipment may be stand-alone grounding components or vents,plumbing vents,furnace or water heater vents etc. (40A) (0.76) (0.80) UL-2703 listed mounting hardware.Optimizers and 11.Wiring must be permanently and completely held off of the _ , modules are bonded to the racking with listed and appoved roof surface per NEC 110.2,110.3(A),110.3(B)&300.4 grounding components. EQUIPMENT O.C.P 5.Equipment operating 150 volts or greater shall only be serviced or replaced by qualified personnel.Field EQUIPMENT: 32 AMP(MAX INVERTER OUTPUT)`1.25(OCP)=40A protection may be in the form of conduit,closed cabinet or (USE 40A BREAKER)(SOLAR BREAKER IN MAIN PANEL) an enclosure which require use of tools to open. 6.Solar Photovoltaic System equipment will be installed in Silfab SLA-M 310(23) WIRE AMPACITY THERMALDER6TE FACTOR NUMBER OF CONDUCTORS accordance with the requirements of Art.690 of the 2014 Solar Edge P370 optimizer(23) VOLTAGE DROP 2017 NEC 310.15(8)(16) 2014 NEC 310.16(6)(2)(a) 2014 NEC 310.15(8)(3)(4) It6 THWN-2 31°-35°C (4-6)MAX. NEC. Solar Edge SE 7600H-US Inverter(1) 90 NC=2*K-Copper"32*20 ft/16510=1.00(.42%VD) (55A) 10.76) `(.80) DiC=2*K-Copper'9.47*50ft/10380=1.17(31%VD) T I 7 1 O O ARRAYlk(-Sting i (Qty i2) 0 Conduit and Conductor Schedule Silfab SLA-M 310(Qty 12)'JJ/?370 Solar eage Ovtan:zers Tag Description Wire Gauge #of Conductors Conduit Type Conduit Size 1 TYPE PV WIRE 10 AWG 2(L1+,L2-) FREE AIR N/A-Free Air 1 BARE CU 6 AWG 1 FREE AIR N/A-Free Air 2 THWN-2 10 AWG 5(L1+,L2-,G) MC Cable Cable — I + + 3 THWN-2 8 AWG 4(L1+,L2-,Neutral,G) THWN-2 2"Conduit - - v - - - 1 —/ I__ l L.+ II Junction Box Main Panel Solar Edge Inverter UTILITY METER -A-- -,_- - - SE 7600H-US �200AA 1 I 7 1 I — _ A C Service -0�\O �/� — Disconnect 6 d n ARRAY iY 1-Stong l 2(Qty I I)Silfab o ,�/ ' SLA-M 310(Qty I1)W/P370 Solar _ I Edge Optimizers I, ti _ 40A Solar _ _/+ L ye _I L2 C 3 < > I PHOTOVOLTAIC SYSTEM GREEN RIDGE POWER WILLIAMS 5/31/18 DESIGN ONE LINE 12070 SW Tigard, OR Whistlers Loop S CAL E: C Designed by Erik Duff SW Whistlers Loop ROOF(SOLAR ARRAY Coverage: Total Roof SOFT:2699 Total Array SOFT:437 Array to Roof%: 16% I'l ‘ Inverter:SE7600H-US with 1111114114,Alliti AIC Service Disconnect -- Array SetBacks: Ridge: 12" N Vents: 12" .... 00 1 PV SYSTEM SIZE: lI'7.13kVV DC '' ssi LEGEND '' TSRF:88% SE SOLAREDGE INVERTER '' El DISCONNECT SWITCH El METER Modules: (23) PANEL MAIN PANEL Silfab SLA-M 310 w/P370 Optimizers Tilt:35 deg. Azimuth: 168 deg. PHOTOVOLTAIC SYSTEM GREEN RIDGE POWER WILLIAMS 5/31/18 DESIGN SITE MAP 12070 SW Whistlers Loop Tigard, OR 97223 SCALE: C Designed by Erik Duff TYPICAL ATTACHMENT TOP SECTION PV Module ITEM# DESCRIPTION DT, _ 1 CAP SCREW,HEX HEAD,5/16'18 X3/4'UNC-2A.GRADE8 1. _-___.� H SHASE,t 1/4"ID FOR 5/16"HARDWARE,A360.1 CAST AL 1. __ 3 LAG SCREW HEX HEAD 5/16 X3"ZINC __ ��_ • ��_ , �. =� 4 POS5 ODX6.5"6063 T5 MILL 1 �=S__SSSS ==_- =�=�� __��= 5 WASHER,SEALING,5/16.IDX 1 1/4 OD EPDM BONDED SS 1. • • �__=��AISS 'I I_S�= �=S_ _�_S S T WASHER,HEX SPLIT- 5/16"X1"18852 � _��=���I�������_��=���_��_��=��� e CAP SCREW,HEX HEAD,5/16"-18 X 1",UNC-2A-18-8 SS 1. `-����� AIINAMATI AITS_ '9,7;," °�° ACTUAL MOUNTING POINT WILL VARY BASED ON —41............................... =- _ �� ROOF TYPE.ATTACHMENT TO RAFTER WILL STAY �_ — - © THE SAME. P.V quick mounts placed 48"O.0 I� 110 � 0 Across Array 0 0 ----'-' . 7.] � � = _ _ ___-_____,- 00 0 0E100 _,1J i © • o 0 .„ -,,,T,,, , . 40 ____ ,,,„,„ _____ O O 1 \ ,.. , ....,,,i, -.0461.•.1 [ 1 .., ...., Aluminum Sunmoto Rail g � MoN0 Existing Rafter Spacing 24"O.0 CROSS SECTION PV Module FRAMING NOTES: // Size- 2x4 Construction Clamp Base _ � Type- Engineered Truss Framed -,------ ,-....„-- -...- „if - Spacing- 24” Q.0 Roof Truss - Ili / Exterior Wall ''�// Alli PHOTOVOLTAIC SYSTEM GREEN RIDGE POWER WILLIAMS 5/31/18 STRUCTURAL 12070 SW Whistlers Loop DESIGN SCALE: C ri �,nnsE Tigard, �R 97223 Designed by Erik Duff