Loading...
Report Job Name: System Reference: Date: APPLIES TO INDOOR UNIT: APPLIES TO OUTDOOR UNIT: - o SEZ-KD09NA4.TH o SUZ-KA09NA o SEZ-KD09NAR1.TH o SUZ-KA09NAR1 ❑SEZ-KD09NA4R1.TH • ItIllilllllllllilll4A �. - 111 006, wk � IIIl1IIIII�I���� 4 OSOF P INDOOR UNIT FEATURES • Concealed horizontal-ducted unit for applications with short duct runs • Quiet operation • Ultra-thin body:7-7/8"high • Built-in condensate lift mechanism(lifts to 21-21/32") • Multiple control options available: -kumocloud®smartdeviceappforremoteaccess JUL. 2 4 2019 -Third-party interface options -Wired or wireless controllers i 4"s tea I' � /A j - • Static capability up to 0.20 in.WG 3UU ,ANG DIkt' S1t- OUTDOOR UNIT FEATURES • Variable speed INVERTER-driven compressor • Innovative Joint Lap DC Motor leads to high efficiency and reliability • Pulse Amplitude Modulation technology • High-performance grooved piping for increased heat exchange efficiency Specifications are subject to change without notice. ©2019 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. ..,i,, ,.<,!,'::::-.!,, „:,4.,..4„:„.,,,,,,,,,,o.'.,12: :',-',1?":"'4,tfp"""imeiFicr;Ati-ouill;::S"EZW-400:414Aii,,:it, t,,,,t1,2,,,,4:-K,44,0:,,9,,,t1,A:,,,4;::;;;; ;;;4:11;;;;i:;,::;i5.;.i,:::;::;,:t:,::::,:,;::,„'",:::';;::;.t,k,,' Maximum Capacity Btu/h 10,900 Rated Capacity Btu/h 8,100 Minimum Capacity Btu/h 3,800 - Maximum Power Input W 1,060 Coolingl Rated Power Input W 670 Moisture Removal Pints/h 1.5 Sensible Heat Factor 0.80 Power Factor % 90/90 Maximum Capacity Btu/h 14,100 Rated Capacity Btu/h 10,900 Heating at 47°F2 Minimum Capacity Btu/h 4,800 Maximum Power Input W 1,670 Rated Power Input W 1,020 Power Factor % 93/93 Maximum Capacity Btu/h 7,300 Heating at 17°F3 Rated Capacity Btu/h 6,700 Maximum Power Input W 1,000 Rated Power Input W 810 Heating at 5°F4 Maximum Capacity Btu/h 5,600 Maximum Power Input W 760 • SEER 15.0 EER1 12.0 HSPF(IV) 10.0 Efficiency COP at 47°F2 3.13 1 COP at 17°F in Maximum Capacity3 2.14 COP at 5°F in Maximum Capacity4 2.16 Voltage,Phase,Frequency 208/230V, 1 phase,60Hz Guaranteed Voltage Range V AC 187-253 Voltage:Indoor-Outdoor,S1-S2 VAC 208/230 Electrical Voltage: Indoor-Outdoor,S2-S3 V DC 24 Voltage: Indoor-Remote Controller V DC 12 Recommended Fuse/Breaker Size A 15 Recommended Wire Size(Indoor-Outdoor) AWG 14 MCA A 1 MOCP A 15 Blower Motor Full Load Amperage A 0.51 Blower Motor Output W 96 Indoor Unit Airflow Rate at Cooling,Dry CFM 317-247-194 - Airflow Rate at Cooling,Wet CFM 285-222-174 Airflow Rate at Heating, Dry CFM 317-247-194 Sound Pressure Level(Cooling) dB(A) 30-26-23 Specifications are subject to change without notice. ©2019 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. Sound Pressure Level(Heating) dB(A) 30-26-23 External Static Pressure in.WG 0.02-0.06-0.14-0.20 Drain Pipe Size In.(mm) 1 1/4(32) Condensate Lift Mechanism,Maximum Distance In.(mm) 21-21/32(550) Heat Exchanger Type Plate fin coil External Finish Color Galvanized W: In.(mm) 31 1/8(790) Unit Dimensions D: In.(mm) 27 9/16(700) H: In.(mm) 7 7/8(200) W:In.(mm) 39 3/8(1,000) Package Dimensions D: In.(mm) 35 7/16(900) H: In.(mm) 14 3/16(360) Unit Weight Lbs.(kg) 42(19) Package Weight Lbs.(kg) 64(29) Indoor Unit Operating Cooling Intake Air Temp(Maximum/Minimum)* °F 95 DB/71 WB//67 DB/57 WB Temperature Range Heating Intake Air Temp(Maximum/Minimum) °F 80 DB//70D6 MCA A 12 MOCP A 15 Fan Motor Full Load Amperage A 0.5 Fan Motor Output W 55 Airflow Rate CFM 1,151 /1,225 Refrigerant Control LEV Defrost Method Reverse cycle Heat Exchanger Type Plate fin coil Sound Pressure Level,Cooling1 dB(A) 46 Sound Pressure Level,Heating2 dB(A) 50 Compressor Type INVERTER-driven Compressor Model KNB073FQDHC Outdoor Unit Compressor Rated Load Amps A 6.6 Compressor Locked Rotor Amps A 8.2 Compressor Oil Type//Charge oz. NEO22//10.8 External Finish Color Munsell 3Y 7.8/1/1 Base Pan Heater Optional(MAC-640BH-U) W: In.(mm) 31-1/2(800) Unit Dimensions D: In. (mm) 11-1/4(285) H: In.(mm) 21-5/8(550) W: In.(mm) 37(940) Package Dimensions D: In.(mm) 14-15/16(380) H: In.(mm) 24-13/16(630) Unit Weight Lbs.(kg) 66(30) Package Weight Lbs.(kg) 73(33) Specifications are subject to change without notice. ©2019 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. • • Cooling Air Temp(Maximum/Minimum)* °F 115/14 Outdoor Unit Operating Cooling Thermal Lock-out/Re-start Temperatures** °F -7/-4 - Temperature Range Heating Air Temp(Maximum/Minimum) °F 75/-4 Heating Thermal Lock-out/Re-start Temperatures** °F -7/-4 Refrigerant Type R410A Charge Lbs,oz 1, 16 Gas Pipe Size O.D.(Flared) In.(mm) 3/8(9.52) Liquid Pipe Size O.D.(Flared) In.(mm) 1/4(6.35) Piping Maximum Piping Length Ft.(m) 65(20) Maximum Height Difference Ft.(m) 40(12) Maximum Number of Bends 10 Notes AHRI Rated Conditions 1Cooling(Indoor//Outdoor) °F 80 DB,67 WB//95 DB,75 WB (Rated data is determined at a fixed 2Heating at 47°F(Indoor//Outdoor) °F 70 DB,60 WB//47 DB,43 WB compressor speed) 3Heating at 17°F(Indoor//Outdoor) °F 70 DB,60 WB//17 DB, 15 WB Conditions 4Heating at 5°F(Indoor//Outdoor) °F 70 DB,60 WB//5 DB,4 WB *Applications should be restricted to comfort cooling only;equipment cooling applications are not recommended for low ambient temperature conditions. **System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. Specifications are subject to change without notice. ©2019 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. • • Filter Box with MERV 8 Filters ❑FBL 1-1 Wireless Signal Receiver ❑PAR-SA9CA-E Wireless Signal Receiver ❑PAR-FA32MA-W Wireless Signal Receiver ❑PAR-FA32MA-E Wireless Remote Controller ❑PAR-FL32MA-E Backlit,Wall-mounted,Wireless Controller ❑MHK1 Portable Central Controller o MCCH1 Wired MA Controller ❑PAR-33MAA Simple MA Controller o PAC-YT53CRAU Touch MA Controller o PAR-CT0IMAU-SB Wired Remote Sensor o PAC-SE41TS-E Wireless Temperature and Humidity Sensor ❑PAC-USWHS003 TH-1 Outside Air Sensor for MHK1 o MOS1 Flush Mount Remote Temperature Sensor ❑PAC-USSEN001-FM-1 System Control Interface ❑MAC-3331E-E Wireless Interface o PAC-USWHS002-WF-1 Thermostat Interface o PAC-US444CN-1 kumo station® o PAC-WHS01 HC-E U o PAC-WHS01 UP-E SNAP Interface IT Extender ❑PAC-WHS011E-E BACnet®and MODBUS®Interface ❑PAC-UKPRC001-CN-1 External Fan/Heater Control Relay Adapter o CN24RELAY-KIT-CM3 Wire for Remote on/off with CN32 connector o PAC-715AD Connector and wire for Operation status/error using CN51 o PAC-725AD Connector cable for remote display o PAC-SA88HA-EP Remote Operation Adapters o PAC-SF4ORM-E 3D i-see Sensor Corner Panel o PAC-SF1ME-E Grille with 3D i-see Sensor"' ❑SLP-18FAEU Installation/Trim Panels ❑PLFY-ITP2 Space Panel o PAC-SJ38AS-E Bottom Return Plate(Converts low-profile ducted indoor unit from rear return to bottom return) ❑BRP-1 External Drain Pump o PAC-KE07DM-E Blue Diamond Sensor Extension Cable-15 Ft. o C13-103 Blue Diamond Alarm Extension Cable-6.5 Ft. o C13-192 Blue Diamond MultiTank—collection tank for use with multiple pumps o C21-014 Blue Diamond Rubber Foot Pads o F10-010 Mini Condensate Pump-230 volt application o S130-230 Advanced Blue Diamond Mini Condensate Pump w/Reservoir&Sensor(208/230V)[recommended] ❑X87-721 -208/230V Drain Pan Level Sensor o DPLS2 (30A/600V/UL)[fits 2"X 4"utility box]-Black ❑TAZ-MS303 (30A/600V/UL)[fits 2"X 4"utility box]-White o TAZ-MS303W Unable to use with wireless remote controller Specifications are subject to change without notice. ©2019 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. Air Outlet Guide ❑MAC-881St Optional Defrost Heater ❑MAC-640BH-U Hail Guard ❑HG-B4 Outdoor Unit 3-1/4 inch Mounting Base(Pair)-Plastic ❑DSD-400P Condensing Unit Mounting Pad 16"x 36"x 3" ❑ULTRILITEI Outdoor Unit Stand-12"High ❑QSMS1201M Outdoor Unit Stand-18"High ❑QSMS1801 M Outdoor Unit Stand-24"High ❑QSMS2401M Heavy Duty Wall Mounting Bracket—Coated Steel ❑QSWB2000M-1 Heavy Duty Wall Mounting Bracket-316 Series Stainless Steel ❑QSWBSS 15'x 1/4"x 15'/3/8"Lineset(Twin-Tube Insulation) ❑MLS143812T-15 30'x 1/4"x 30'/3/8"Lineset(Twin-Tube Insulation) ❑MLS143812T-30 50'x 1/4"x 50'/3/8"Lineset(Twin-Tube Insulation) ❑MLS143812T-50 65'x 1/4"x 65'/3/8"Lineset(Twin-Tube Insulation) ❑MLS143812T-65 • Specifications are subject to change without notice. ©2019 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. • 345(13-19/32) Drain'ire O.D.032 1-1/4 Unit: mm (inch) (Emergency draining) M y— 6; 371-15/32 m III Suspension bolt hole10'3-i5/1s 21 13/16 157.5 6-7/32 _- 1 19/32 'O u -_ •___:/4-1430(9/16.1-3/16)Slot 1.1/2 WM 37 1-15/32 2°E-o2.9 1/8) � fl rn —i L-02.9 1/8 Oct „, a - i 2)''''S2 • a n I• a < 0 =Air Air zr outlet nlet8 Kial ('-'73M a 11 13/32 - - n I fir Air filter 49 I 625 Suspension bolt.itch 1p ^ N 16(1-15/16 (24-5/8) °',1 PI Drain pipe(O.D.032(1-1/4)) Knockout hole 027 1-3/32 N .... n (Indoor/outdoor connecting line) m 761;(73176."-:/11/(3')2 00(7.9/16) e N Knockout hole 027 1-3/32 N 23 29/32 677 26-21/32 ,' 10(13/32) C�ontr—ol bo—x ar ZS o (Remote controller transmission line) 8 e 116 70 a-19/321 (2-5/2) Terminal block(Indoor/outdoor connecting line) 2x2-02.9(1/8) `” 270(10-21/32 Terminal block(Remote controller transmission line) t7Refri eranf.i.iro ©Ref i.erant i.in. Drain pipe(O.D.032(1-1/4)) are connection(qas) flare connection(liquid) (Spontaneous draining) Less than 300 (11-13/16) �— 1311 ` 111 \57. 170±5 6-29/32±7/32 IiC N F-,pII�__ 5` �-':�/ ..,\90.19 Access door (Actual length) II w N _-_-_•qr C' ,079 �4.g 4*, T ,, . v v, Ceiling surface Access door Note2 G Lj `P��.�" 'if,�ijji\iOAT,I311, N E § t (7\?,,,,s ` ‘ :ilk 31 o Make the access door at the appointed position properly a s Iso 11":5)a o 1�1e for service maintenance. 5/3,) r 2330 11�o<e X11 Drain hose I.D.032 1-1/4 zj <accessory> Required space for service and maintenance mm(in.) Sizes A B C 0 E F G H J K L M N1QGas pipe ()Liquid pipe 09 kBtu/h (2q/?6) (279-54 (3798) $660) 0 7 (?3-05?) (800) X260 5 (19101016) 16 (8396)(3910) 12 kBtu/h 09.52(3/8) _ 900 952 998 860800 1000 860 700 1039 990 15 kBtu/h (35-7118) (37-1/2) (39-5/16) (33-718) 9 (31-1/2) (39-3/8) (33-718) 7 (27-9116 ) 20 ;40.29/32) (39) 06.35(1/4) 18 kBtu/h 1100 1152 1198 1060 1000 1200 1060 900 1239 1190 012.7(1/2) (43-5116) (45-318) (47-3/16) (41.3/4) 11 (39.318) (41.1(4) (41-3)4) 9 (35-7116) 24 ;48-25/32'(46.7/8) Note i.Use M10 screw for the suspension bolt(field supply). 2. Keep the service space for the maintenance at the bottom. 3. This chart indicates for size 15 kBtu/h model,which has 3 fans. Sizes 09,12 kBtu/h models have 2 fans. Sizes 08 kBtu/h model has 4 fans. 4. When an inlet duct is used,remove the air filter(supply with the unit),then install the filter(field supply)at suction side. Specifications are subject to change without notice. ©2019 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. Unit: inch REQUIRED SPACE Basically open 4 in.or more 15-3/4 Drain hole 01-5/8 without any obstruction in front Air in and on both sides of the unit. 4.0 ;51.? of mote Air in r More 0Airout 41 1-9/16 oce ,,' 14rn'or 2-3/8 x13/16 Oval hole g'\n oc fore ` 7/8 29/32 11-1/4 17/32 handle Open two sides of left, IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII I right,or rear side. IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII N IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII M IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII Liquid pipe 1/4(flared) uunnnnunuunuunnunnnnn — �� Gas pipe 3/8(flared)(KA09/12) (flared)(KA15) Co'' 11-29/32 6-23/32 5-15116 19-11/16 31-1/2 2-23/32 AMITSUBISHI ELECTRIC COOLING & HEATING 1340 Satellite Boulevard,Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com c E1�us FORM#SEZ-KDO9NA4&SUZ-KAO9NA-201903 ere Intertek Specifications are subject to change without notice. ©2019 Mitsubishi Electric Trane HVAC US LLC.All rights reserved.