Loading...
Report (61) Project: Gaarde Christian School - HD Job Bard 19178 SWCE kD39 Plan-ID Qty Model No Description Page Wm-01 2 T30S1-A04WP4XXE Wall-MountTM Heat Pump 208/230-1 ph 3 Warranty Document for Wall-Mounts, Package, Oil Furnaces 6 y w Project: Gaarde Christian School - HD Plan-ID:WM-01 Page: 3 Bard Job 19178 Quantity: 2 s'%CEIp1 Model Number:T30S1-A04WP4XXE - Cooling Performance @ Project Parameters Supply Air Performance Cooling Capacity 28,000 Btuh Total Supply Air 900 cfm Sensible Capacity 21,200 Btuh Blower Motor 1/3 hp Integrated Efficiency 13.7 IPLV ECM Blower Motor Efficiency (at AHRI) 10.80 EER Non-Ducted Efficiency Stage 1 14.00 EER Outdoor DB Temp 95.0 °F Air flow is based on Wet Coil Entering DB Temp 80.0 °F Electrical Data Entering WB Temp 67.0 °F Leaving DB Temp 58.2 °F Power Supply Leaving WB Temp 57.3 °F pp y 208/230 Volts 1 Phase HertHP Heating Performance 60 Minimum Circuit Ampacity 44 Amps HP Capacity @47.0°F 27,800 Btuh Maximum External Fuse or 50 Amps Circuit Breaker HP Capacity @17.0°F 16,600 Btuh HP COP @47.0°F 3.3 Field Power Wire Size 8 HP COP @17.0°F 2.2 Ground Wire 10 HP Heating Outside Temp 10.0 °F Based on 75C copper wire,All wiring must conform to the National HP Heating Entering Air 70.0 °F Electrical Code and all local codes HP Heating Capacity 9,200 Btuh Caution:When more than one field power circuit is run through one • HP Heating Leaving Temp 79.5 °F conduit,the conductors must be derated.Pay special attention to note 8 of Table 310 regarding Ampacity Adjustment Factors when more I' than three(3)current carrying conductors are in a raceway. Electric Resistance HeatJ _.... Approximate Installed Weight Nominal Heat Size 4 kW Electric Heat Voltage 240 Volts Unit Weight 400 lb Heat Output 13,652 Btuh Option Weight 51 lb HP Leaving Air 79.5 °F Total Weight 451 lb HP with Elec Res Htg Lv Air 93.5 °F Factory Options Selected A- 208/240 Volt 1 phase 04 -4 KW w/Circuit Breaker Disconnect W-Telecom Economizer Ventilation Option - Enthalpy Control P - 2-Inch Pleated Filter MERV 8 4 - Buckeye Gray X - Front Outlet X - Standard Coils E - Standard Controls + LAC Field Installed Accessories Field Supplied Accessories TH8321 WF1001 TSTAT 2H2CAC 3H2CHP WIFI HW Project: Gaarde Christian School - HD Plan-ID:WM-01 Page: 4 Bard Job 19178 Quantity: 2 SINCE It 11 Model Number:T30S1-A04WP4XXE Standard Product Features Right Side Control Panel •Two Stage - Step Capacity Unit • Solid State Electronic Heat Pump Control provides efficient 30-minute defrost cycle. Includes a thermistor sensor and speed up terminal for service along with a 10-minute defrost override. • Five Minute Compressor Time Delay is buit into the electronic heat pump control. • Emergency Heat Circuit permits continuous operation of the system • ECM Indoor Blower Motor with super-high efficiency, low sound levels and soft-start capabilities.The motor is self adjusting to provide the proper airflow rate for the staged capacity, and for higher static pressure in ducted installations without user adjustment or wiring changes • Scroll 2-Stage Compressor: Eliminates need for crankcase heater. Double isolated floating compressor mounting system, compressor sound blanket, and discharge muffler for reduced outdoor sound level. • R-410A Refrigerant • Grooved tubing and enhanced louvered fin coils •Twin Blowers • Foil Faced Insulation (all insulation exposed to airstream) • Liquid Line Filter Drier • High & Low Pressure Switches are Auto-Reset • Galvanized 20 Gauge Zinc Coated Steel Cabinet • Electrical Components are easily accessible through a right side, service panel opening • Features a lockable, hinged access cover to the circuit breaker or Disconnect • Separate Filter Service Door • Air Filter size— 16" x 30" x 2" • Condenser Fan and Motor Shroud Assemble slides out for easy access • Slope Top with 4 degree pitch for water run-off is standard •Top Rain Flashing is provided • Complies with efficiency requirements of ANSI/ASHRAE/IESNA 90.1-2013. • Certified to ANSI/AHRI Standard 390-2003 for SPVU (Single Package Vertical Units) • Intertek ETL Listed to Standard for Safety Heating and Cooling Equipment ANSI/UL 1995/CSA 22.2 No. 236-05, Fourth Edition. • Project: Gaarde Christian School - HD Plan-ID:WM-01 Page: 5 Bard Job 19178 Quantity: 2 S' `t'@'" Model Number:T30S1-A04WP4XXE • Dimensions of Basic Unit for Architectural and Installation Requirements (Inches) Width Depth Height Supply Return (W) (D) (H) A BCD E F G 1 38.200 17.125 70.563 7.88 27.88 13.88 27.88 40 10.88 25.75 17.93 J K L MN OP QR S T 26.75 28.75 29.25 27 2.63 39.13 22.75 9.14 5 12 5 Built In D E Rain Hood 7.88- I' © F � 4°Pitch Q 31.88 r W Heater "" '�1.00 7 Access-,, I J Panel _ ; : „. _,. R I Electric A Side Wall . ..Supply Air Opening 1 Heat— — Mounting Brackets —... 1 l C.Breaker/ _ (Built In)-,.., 1 S I. Disconnect i '� B Access Panel" ` 1.250L.- I (Lockable ) 1) i' Top Rain Hood for ERV andFlashing ECONWMS models I Shipping S , � ,i only__ 1 Location , I 5.88 Filter Access Panel \\.„ . . i i Optional H Electrical Return Air Opening s T--. Standard Entrances flush vent F ,Ventilation Air i I / r :1 door for ' non ERV/ ® E .�."tat .i Econ. / . E ] models ._,_ • }' .Q S G F} S<'S } Low Voltage / ,.., K L . . l Condenser{ I Hood for Electrical/ f Cond.' i ECONWMT S Air Outlet models. Entrance Air _< i M P { y ' efb 1 High Voltage / .(,_)- iniet i 0 1 # IIIElectrical! IEntrance ^Z, r1,,, 4 T Drain N—.- — Bottom Installation Front View Side View 0-- Back View Bracket H— Project: Gaarde Christian School - HD Job 19178 Page: 6 Warranty Document for Wall-Mounts, Package, Oil Furnaces Bard SINCE 011 Bard® Limited Warranty SINCE.1919 J For units applied within the United States,Puerto Rico, US Virgin Islands, Guam, Canada and Mexico Climate Control Solutions Limited Warranty To Original Purchaser: Bard Manufacturing Company, Inc. Bryan, Ohio 43506 warrants to you, the original purchaser, that your Bard product will be free from defects in materials and workmanship when used under normal conditions from the installation date through the time periods outlined in the"Duration of Warranty" section (see reverse side). Proof Of Purchase: You must be able to show us the date on which you purchased your product when you make a claim under this warranty. Your owner's registration card filed online at www.wallmountwarranty.com or your contractor's invoice, bill of sale,or similar document is sufficient at time of warranty claim. If you can not show us the actual date of purchase,the time periods in this warranty will start on the date that we shipped your Bard product from our factory. What This Warranty Does Not Cover: (Also see Duration of Warranty on reverse side.) This warranty does not cover defects or damage caused by: 1. Alterations not approved by us; improper installation (including over or under sizing), improper repairs, or servicing;or improper parts and accessories not supplied by us. 2. Misuse or failure to follow installation and operating instructions(including failure to perform preventative maintenance)or limitations on the rating plate. This includes failure to use low ambient controls on all applications requiring compressor operation in cooling mode below 60F outdoor ambient. 3. Any corrosion from operation in a corrosive atmosphere(examples:acids, halogenated hydrocarbons or environmental conditions). 4. Parts that must be replaced periodically(such as filters, oil nozzles, mist eliminators, ERV belts, pile seals,etc.). 5. Improper fuel or electrical supply(such as low voltage,voltage transients, power interruption, and units on generators with no brownout protection). 6. Accidents or other events beyond our reasonable control (such as storm,fire,or transportation damage). 7. Defects that happen after (a) Anyone has tampered with the product. (b) The product has been improperly serviced according to accepted trade practices; (c) The product has been moved from its original place of installation; or, (d) The product has been damaged by an event beyond Bard's control (See also No. 5 above). 8. Consequential damages(such as increased living expenses while the product is being repaired). Some states do not allow the exclusion or limitation of incidental or consequential damages.so the above limitation or exclusion may not apply to you. 9. This warranty has certain limitations for units installed on over-the-road trucks,vans and trailers. (See reverse side.) 10. Cost of service call at installation site to diagnose causes of trouble, labor to replace defective component or transportation costs for replacement parts. 11. This Limited Warranty does not apply to products installed or operated outside of the US, Puerto Rico, US Virgin Islands, Guam,Canda and Mexico. Units operated in coastal areas where the operating environment is exposed to airborne saline particles(typically 5 miles from coast line) must have corrosion protection or warrenty claims will be declined on corrosion-based cabinet and part failures. 12. Bard does not endorse,approve or certify any online sales of its products through auction websites,online retailers, liquidators or any other method of online sales direct to consumers. Bard will not honor the factory warranty of any Bard equipment purchased over the Internet. Your Responsibilities: You are responsible for- 1. Preventative maintenance of the product(such as cleaning and replacement of filters, nozzles and other consumable parts). 2. Insuring that the instruction manual is followed for care and use of your product. 3. Insuring that your product is installed by a competent,qualified contractor, following all local and national codes,and industry standards. What We Will Do About A Defect: We will either repair or replace the defective part only. Replacement parts may be reconditioned parts. The warranty for the repaired or replaced part will last only for the remainder of the warranty period for the original part. For Heat Exchangers that are no longer available,we will give you credit equal to the then current retail price of an equivalent Heat Exchanger. Defective parts and a properly completed Bard parts warranty form must be returned to a Bard distributor for submitting to Bard to be eligible for a warranty credit or replacement. Credits are issued to the Bard distributor. We will not pay or be responsible for labor or defective/replacement part transportation costs or delays in repairing or failures to complete repairs caused by events beyond our reasonable control. What You Must Do 1. Tell your heating and air conditioning contractor as soon as you discover a problem and have the contractor make repairs. 2. Pay for all transportation, related service labor, diagnostic charges, refrigerant, refrigerant recovery and related items. Service If your product requires service,you should contact the contractor who installed it or the contractor that has been providing the product's preventative maintenance and repair service. You may find the installing contractor's name on the product or in your Owner's packet. If you do not know who that is.you should contact a competent, qualified contractor to make the repairs. If in doubt,you should contact the nearest distributor that handles Bard products(www.barcihvac,corn). Please note that contractors and distributors that handle.Bard products are independent contractors and distributors, and therefore, are not under the direction of Bard Manufacturing Company, Inc. Only Warranty This is the only warranty that we make. There are no other express warranties. All implied warranties are limited in duration to the duration of the applicable written warranty made above, Some states do not allow limitations on how long an implied warranty lasts, so the above limitation or exclusion may not apply to you. Other Rights This warranty gives you specific legal rights and you may have other rights which vary from state to state. BARD MANUFACTURING CO., INC. — BRYAN, OHIO 43506 FormNo. 7960-425 Dependable quality equipment . . since 1914 Issued: 05/08/19 Supersedes: 01/15118 Project: Gaarde Christian School - HD Job 19178 Page: 7 Bard I Warranty Document for Wall-Mounts, Package, Oil Furnaces SINCE Duration Of Warranty is limited to defects arising during the periods shown in the following table: Model Number Series: -Number of Years from Installation Date CO- Includes all Models in each Series&which may have additional characters. (Example:W12- Compressor Sealed System All Other Heat 70A includes W36A w/additional characters.) CD Components 00)0 Functional Parts CP Exchangers AIR CONDITIONERS W12A,W17A,W18A,W24A,W30A,W36A,W42A,W48A,VV60A,W70A,W72A,W090A, W12OA,W180A,W17L,W18L,W24L,W3OL,W36L,W42L,W48L,W6OL,W7OL,W72L, 5 5 5 WA3S,WA4S,WA5S,WL3S,W4LS,WL5S,D25A,D28A,D35A, D36A,D42A,D48A,060A, N/A D25L,028L,D35L,036L,042L,D48L,060L,424A,430A,436A,442A,448A,460A, 130A, 136A,142A, 160A AIR SOURCE HEAT PUMPS W18H,W24H,W3OH,W36H,W42H,W48H,W6OH,C24H,C3OH,C36H,C42H,C48H, C6OH,724H,T3OH,T36H,T42H,T48H,T6OH,T24S,T30S,T36S,T42S,748S,T603, 5 5 5 N/A Q24H,430H,436H,442H,443H,448H,460H, 130H, I36H, 142H, 48H, 160H, 136Z, I48Z, 160Z ENVIRONMENTAL CONTROL UNITS 5 5 1 N/A W3RV,W4RV,W5RV,W6RV,W3LV,W4LV,W5LV,W6LV EQUIPMENT SHELTER UNITS 5 5 1 N/A W"A2P,W**AAP,WR**,D**AAP,HR**, H12A,H72A GEOTHERMAL/WATER SOURCE HEAT PUMPS 5 5 5 N/A QW2S,QW3S,QW4S,QW5S CHILLED WATER N/A 5 5 N/A 4C50(No Compressor) GAS/ELECTRIC WALL-MOUNT 5 5 5 10 W24G,W300,W36G,W42G,W48G,W600,WG3S,WG4S,WG5S OIL FURNACES ECM"V"Blower Models FC085,FH085,FH110,FLF075,FLF110,FLR075,FLR100, N/A N/A 108) LIFETIME(4) FLR13O PSC"D" Blower Models FC085,FHO85D,FH110D,FLF085,FLF110, FLR085, FLR11O, N/A N/A 5 LIFETIME C) FLR140 SOF: SOF175,SOF265 N/A N/A 1 10 ACCESSORIES Factory/Field Installed Bard Ventilation and Heater Packages N/A N/A 5 N/A - Bard branded Thermostats/Temperature Controllers N/A N/A 5 N/A LC1000,LC1500,LC2000,LC5000,LC6000,LV1000,MC4002,DC3003,TEC40,BG1000 N/A N/A 1 N/A Humidistats,CO,Controllers and all other field installed accessories N/A N/A 1 N/A not listed separately 0 For equipment that did not have the warranty registration card returned to the factory,the warranty period starts when the product was shipped from the factory or online. (2 Heat transfer coils(refrigerant to air coils for air source and coaxial coils for water source unitsl are covered for leaks for 5 years. Physical damage to air side coils resulting in leaks or insufficient airflow,or fin deterioration due to corrosive atmosphere Isuch as acids,halogenated hydrocarbons or coastal environmental conditions)are not covered. Leaks in coaxial coils due to freezing of the coils are not covered. Copper coaxial coils for OW are not warranted for ground water/open loop installations. (2 Functional parts warranty iv 1-year for all telecommunication,electric switch stations,pump stations arid similar applications. This also applies to all OTR(over the road)applications. 9) Limited lifetime warranty on Heat Exchangers applies to original purchaser in private,owner occupied residences. Subsequent owners and commercial uses are warranted for 20 years from date of installation. CD All OTR(over the road)applications that are moved from one location to another: Factory Warranty applies up to the point of initial start-up and test at all OEM manufacturing locations or subsequent outfitting facility. Once it goes into OTR service,the warranty expires immediately for compressor and sealed system components. This OTR exemption does not apply to relocatable classrooms,construction or office trailers. (2 Standard warranty for non-registered Oil Furnaces is 5-year parts. Must be registered at www.willrnourtwarranty corn within 90 days of installation for the 10-year parts coverage to be in effect. (2 Factory coated coils have a"5"year warranty in corrosive environments that are listed as approved. Recognized as a leader in the HVAC industry,Bard combines quality products and outstanding service with innovation and technological advances to deliver high- performance heating and cooling products around the world. Please visit www.bardtwac.com for additional information regarding warranty and product information. • BARD MANUFACTURING CO., INC. - 1914 Randolph Dr. - BRYAN, OHIO 43506 Form No. 7960-420 Dependable quality equipment . . since 1914 :red' des: 01/151/11: