Loading...
Plans (25) RECEIVED :Es V8 SCOPE OF WORK FIRE ALARM EQUIPMENT SYMBOL LISTtr MODIFY AN EXISTING ADDRESSABLE CENTRAL STATION FIRE ALARM SYSTEM MAY 23 2019 SYMBOL DESCRIPTION NEW EXIST PART # ROUGH-IN / NOTE MOUNTING HEIGHT WHICH INCLUDES THE ADDITION OF HORN/STROBES, AND STROBES. (,;I I y 01- IIGARD FACP FIRE ALARM CONTROL PANEL 1 SILENT KNIGHT EXISTING EXISTING 53 3UILDING DIVISION 5808 INACoi FIRE ALARM REMOTE POWER SUPPLY 1 POTTER EXISTING EXISTING41111 z PSN-106 80" MIN TO LENS BOTTOM AFF a GENERAL NOTES /5 HORN/STROBE - WHITE 3 SYSTEM SENSOR 4" SQUARE, 4" OCT, SINGLE OR 96" MAX TO TOP OF LENS AFF 44�II (NAC AND CANDELA NOTED AT DEVICE) P2WL DOUBLE GANG BACK BOX Ilk Illk. 6" MIN TOP OF LENS TO CEILING . STROBE - WHITE SYSTEM SENSOR 4" SQUARE, 4" OCT SINGLE OR 80" MIN TO LENS BOTTOM AFF 1. THE FIRE ALARM SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH NFPA ®° (NAC AND CANDELA NOTED AT DEVICE) 4 SWL DOUBLE GANG BACK BOX 96" MAX TO TOP OF LENS AFF ` e. 72 AND NFPA 70, ARTICLE 760, POWER LIMITED SYSTEMS. 6"F MIN TOP OF LENS TO CEILING 2. FIRE ALARM WIRE INSTALLED IN VERTICAL RUNS AND PENETRATING MORE THAN ONE FLOOR SHALL BE RISER RATED. PLEASE PROVIDE 3. FIRE ALARM WIRE RUN IN DUCTS OR PLENUMS SHALL BE PLENUM RATED. 4. ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT. COMPLETED NFPA T2 5. A SYSTEM GROUND MUST BE PROVIDED FOR EARTH DETECTION AND .°..'•* LIGHTNING PROTECTION DEVICES. RECORD OF 6. DEDICATED BRANCH CIRCUIT(S) AND CONNECTIONS SHALL BE MECHANICALLY COMPLETION AT �b°L� PROTECTED. l'i 7. CIRCUIT DISCONNECT MEANS SHALL HAVE A RED MARKING, IDENTIFIED AS "FIRE ALARM CIRCUIT". NOTIFICATION CIRCUIT SCHEDULE INAL INSPECTION 8. AUDIBLE ALARMS SHALL CONFORM TO SECTION 18.4.3 PUBLIC MODE (NFPA 72). VOLTAGE DROP CALCULATIONS 9. CENTRAL STATION MONITORING SHALL BE DOCUMENTED UPON COMPLETION OF THE PROJECT IN ACCORDANCE WITH SECTION 26.6.3 (NFPA 72). 10. A RECORD OF COMPLETION SHALL BE PROVIDED TO THE FIELD INSPECTOR CKT # DEVICE LOCATION / AREA CIRCUIT TOTAL WIRE WIRE VOLT VOLT ACCEPTED VOLT AT THE ACCEPTANCE TEST INSPECTION IN ACCORDANCE WITH ORIGIN AMPS DIST SIZE DROP AT EOL DROP DROP % SECTION 14.6.2.4 (NFPA 72). MODIFIED CIRCUIT N-1 NAC01 PANEL TRIP NAC01 PANEL TRIP FACP _0.010 30 14 0.00 20.40 YES 0.01% N-2 OLD NAC1 (MEASUREMENT ASSUMED) OLD NAC1 FACP 1.500 450 14 4.14 16.26 YES 20.32% N-3 OLD NAC2 (MEASUREMENT ASSUMED) OLD NAC2 FACP 1.500 450 14 4.14 16.26 YES 20.32% t� N-4 HORN/STROBE, STROBE FLOOR 1 - FINANCIAL INVEST _ FACP 0.468 305 14 0.88 19.52 YES 4.30% VALIDITY OF PER+� I� N-5 HORN STROBE, STROBE FLOOR 1 NAC01 1.018 405` 14 2.53 17.87 YES 12.41% V THE ISSUANCE OF A PERMIT N-6 HORN STROBE, STROBE FLOOR 1 NAC01 0.744 346 14 1.58 18.82 YES 7.75% Z [}� N-7 HORN STROBE, STROBE FLOOR 2 NAC01 0.482_229 14 0.68 19.72 YES 3.32% BASED ON C EU�T�'�'(M OPERATIONAL MATRIX N-8 HORN STROBE, STROBE FLOOR 3 NACO1 0.449 200 14 0.55 19.85 YES 2.70% DOCUMENTS AND OT {E►i NO CHANGES N-9 HORN STROBE, STROBE FLOOR 3 NAC01 0.639 215 14 0.84 19.56 YES 4.14% DATA SHALL NOT PREVENT N-10 SPARE SPARE NAC01 0.000 0 14 0.00 20.40 YES 0.00% MI THE CODE OFFICIAL FP'DM n MON *****END-OF-LINE METHOD OF CALCULATION REQUIRING THE CORRE OF ERRORS. O:» 105.4 SITE Z m S W H sly 4,4_ BATTERY CALCULATIONS CO °WOOD /-iv ADDRESS SCHEDULE SILENT KNIGHT 5808 Z ZN u, NO CHANGES PART # DESCRIPTION QTY STANDBY STANDBY TOTAL ALARM ALARM TOTAL V Q rn C C CITY OP TIG 5808 MAIN CIRCUIT BOARD 1 0.1700 0.1700 0.3650 0.3650 lil0 0 586OR REMOTE ANNUNCIATOR 1 0.0200 0.0200 0.0250 0.0250 w Q RE EWED FOR CODE CO SK-PHOTO PHOTOELECT ADDR HEAD 14 0.0003 0.0042 0.0065 0.0910 V CC w p -1 SK-HEAT HEAT DETECTOR HEAD 1 0.0003 0.0003 0.0065 0.0065 Z 0 Cl) p Q A,r proved.• illSK-RELAY RELAY MODULE 8 0.0004 0.0032 0.0065 0.0520 Q 0 U g W •TC: ` I .- RISER DIAGRAM SK-MINIMON MINI MONITOR MODULE 6 0.0004 0.0024 0.0065 0.0390 ZU S OC Ce m . r , , SK-PULL-DA PULL STATION ADDR 5 0.0003 0.0015 0.0003 0.0015 if- '" a0 11 . u_ o emit#: .J ->ii NO CHANGES N-1 (NAC1) NEW NAC01 PANEL TRIP 1 0.0000 0.0000 0.0100 0.0100 DWG REV.C a • tigress: I£ _ >) w COI % / N-2 (NAC2) OLD NAC1 1 0.0000 0.0000 1.5000 1.5000 0 I DATE05/21/19 Al N-3 (NAC3) OLD NAC2 1 0.0000 0.0000 1.5000 1.5000 Suite tt: `� / N-4 (NAC4) FLOOR 1 - FINANCIAL INVEST. 1 0.0000 0.0000 0.4680 0.4680 By, Date: - 3©-)`� / STANDBY TOTAL 0.2016 ALARM TOTAL 4.0580 MODIFIED CIRCUIT *CALCULATIONS BASED ON 24 HR STANDBY TIME & 5 MIN ALARM TIME* DRAWN BY: illir . III�II..IIIIII AMPS (A) X TIME (H) AMP-HRS (AH) 20% DERATE TMB II II STANDBY 0.2016 X 24 4.8384 CNECEDBY: ,VIII 111111' ALARM 4.0580 X 0.0833 = 0.3382 - BJB TOTAL AH = 5.1766 6.2119 FILE NAME: FA.dwg BATTERIES TO BE INSTALLED: 7.0 AH DRAWING t FA-1 ORIG.SHEET S WE:11,x7 /GF GWGS IN SET: SHEET 1 OF 3 /14 ggE .... ri ig „ , _2_1 . .._..L " H / / / 1 / /, / �-1.- ._—...-4.._. �k L % / ON F l 8 L / 1J / / // N 510 C,/ / / , / , z, , ii4� '. :r1'.4 Li' 1 _ _ 7L- r-. 3 � ! 75CD ° 4.—.,.. g illi% ,_,re-7 /'A.fir j aii!' .. G _, s , IT L _ / Ar /,!,7 X11 BREAK/COPY I jj/ CONFERENCE CONFERENCE / 16, A 103 Ii ; 107 108 AREA OF WORK N-4.6COTN-4.1 N-4.2 15CD1IPOAS5 15CD ° 15CD N-4.7 COOVERALL � UILDI \ G 15 ' 1 s NOT TO SCALE N_4.3 75CD ■ V � Z w g ICC W • OPEN OFFICE STAFF ~` 0 N-4.5 109 102 75CD Z ILI N-4.4 OPEN OFFICE C 15CD 100 I- H W CO R / M-8<8./P zLIU Q go (DQ N-5:11 p EOL 0 t6OJ 30CD Z U cn 6-4. 11 I _ii _,_ ,} -- ❑' OFFICE `-- L 101 �: a . �, gw Z •" C' C � il DWG REV. ogre 0 05/21/19 1 I IT. _ ti� ,/,,,,,,,,.....di_ -. DRAWN BY: TMB CHECKED BY: BJB FILE NAME: NOTE: ALL FIRE FAaws DRAWING ALARM EQUIPMENT 01ST Fl_ 0 4' 8' 16' FA-2 IN SHADED AREA ORIG.SHEET SIZE:,1x,r IS EXISTING 2 SCALE: 1/8"--t—o" ADF DWGS IN SET: SHEET 2 OF 3 gg� al ILk,c.. 11111100.11. 8 to i 1__.21)a OO a 0 ei, ) % ,. ©,,..,. 1 1 0 ;11111,4ZwPri .--",lt, FROM NAC SOURCE STFMP �� o . OR J } }i v; TONEXOTR DEVICE PREVIOUS DEVICE !.u! _i1. �_ I I E1 EOL(4.7KG) I V • 1 NAC - NAC - V NAC IN NAC OUT Z (TYPICAL 14/2C) (TYPICAL 14/2C) NAC + S NAC + CC L S - LLI a li --±'L ��� O u z Q_,_ _ W------------a Do 9 WS M CAUTION: �` H W DO NOT LOOP WIRE UNDER �r TERMINAL 1. SYSTEM SENSOR v/ = 1"- BREAK WIRE RUN TO PROVIDE W co UNIVERSAL MOUNTING PLATE SUPERVISION OF CONNECTIONS. W z N SW,P2W,SCW,PC2W z /J ( N L-SERIES:SWL,P2WL, � (Wj d' 6. m SCWL,PC2WL111.1-11:1- Z ......• 0 LL SYSTEM SENSOR Q ov � J NOTIFICATION 0 all SCALE: NTS Q o U W Z U S. WLL a i n LL- DWG LDWG REV./DATE 0 05/21/19 DRAWN BY: TMB DREDGED BY: BJB FLE NAME: FAdwg DRAWING k FA-3 ORIG.SHEET SDE:1 1 k IT #OF DWGS IN SET: SHEET 3 OF 3