Loading...
Report (52) epic GINEERING Thursday, May 30, 2019 RECEIVED Auric Solar V 2310 S 1300 W JUN 11 2019 West Valley City, UT CITY OF TIGARD BUILDING DIVISION RE: ROOF EVALUATION FOR 11389 SOUTHWEST IRONWOOD LOOP, TIGARD, OREGON As per your request I evaluated the support system for the proposed solar array for the residence located at 11389 Southwest Ironwood Loop, Tigard, Oregon. It is my understanding that the roof structure consists of two different framing methods as shown in Figure 1, attached to this letter. The areas labelled Area 1 consist of pre-engineered trusses at 24" O.C. The area labelled Area 2 consists of simply supported 2x12 rafters @ 24" O.C. The snow load is less than 50.0 psf and the wind load is less than 120 psf. Area 1: Oregon Structural Specialty Code (OSSC) 2014 Section 3111.5.3 indicates that solar panels that are installed on conventional light-framed construction with pre-engineered trusses or roof framing members with a maximum spacing of 24" O.C. shall qualify as prescriptive and shall not require an engineered design. Area 2: Design Loads: Dead 12 psf Snow (+rain surcharge) 25 psf Solar 3 psf It was found that the existing rafters are adequate to support the addition of solar panels in Area 2, with the calculation attached to this letter. it \V st Vallev,['T 801-955-5605 yWilliston, VD 701-774-5200 1 Veinal,UT 435-781-7113 Mesa,AZ 4$0-309-6504 ., epice1,11/ .azr M ' r x ;7:711/4,7,-, z� � „ , �� ,���1 . t- =t } �" _ '`::,.,: i �, -,-, -- -. ,, ':{mak, ., , t £ - Y .,in;I:. . z :`` t � ;',,,,,,7,,-.7. 4777:T.--2 ,- As both sections of the roof are adequate per code or adequate per the attached supporting calculation, it is my recommendation that the existing roof will safely and adequately support the solar panels. The roof attachments should be staggered such that the mounting hardware can be attached to the roof @ 48" O.C. The racking should be installed per the manufacturer's specifications directly to the truss top chords or rafter. The attachments consist of a 5/16" or 18/8 SS lag screw with 2" minimum penetration into the truss top chord or rafter. The fasteners should be centered on the member width. • I can be reached at 435-654-6600 extension 123 with any questions. Respectfully, i �Q PR�}FF3 ��.`� ty0,4.-,_,. 1 Ne6.� Sia rWAII -" ORE ,f'4 q 9'J IA,�j`. /30/19 EXPIRES 14,1 ,y Adam Huff, S.E. Epic Engineering, P.C. a CD 0 70 .s \ O / M / \ A I:=1 ❑ ❑ II- a waxamm...'. •:��.l, Wit;,. �,.a... isionwilLimriabwarli lama" � / , ' , ill& • II lin alM lin 'IA hla / '\\,-0_, \ ...„ liks-iw nis, 10.16, �t?t =ED= Mkiilk - ituallqi, ,. \ps, : 111 EN // - \ A - MI 11111 . ,\ s 14 lailMENLIIN P Minaleill / •WMill‘lnif. / / / . / 1 / 1 LEGEND r AREA 1 15 NP BLACK AREA 2 Figure 1: Roof Framing Areas Title Block Line 1 Project Title: You can change this area Engineer: using the"Settings"menu item Project ID: and then using the"Printing& Project Descr: Title Block"selection. Title Block Line 6 Prsr,Med 30 MAY 2019, 8 MAM Wood Beam File=N:\PROJ\0R3H3D-E1AW7PH9 K\ETOKQP-J\Byron Enercalc.ec6 Software copyright ENERCALC,INC 1983 2019,Build 10.19.1.30 DESCRIPTION: RJ-1 CODE REFERENCES Calculations per NDS 2015, IBC 2015, CBC 2016,ASCE 7-10 Load Combination Set :ASCE 7-10 Material Properties Analysis Method: Allowable Stress Design Fb+ 900 psi E:Modulus of Elasticity Load Combination ASCE 7-10 Fb- 900 psi Ebend-xx 1600ksi Fc-Prll 1350 psi Eminbend-xx 580ksi Wood Species : Douglas Fir-Larch Fc-Perp 625 psi Wood Grade :No.2 Fv 180 psi Ft 575 psi Density 31.21 pcf Beam Bracing : Beam is Fully Braced against lateral-torsional buckling Repetitive Member Stress Increase D(0.03)S(0.05) b a b b b ( '',.. 2x12 Span= 15.250 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loads Uniform Load: D=0.0150, S=0.0250 ksf, Tributary Width=2.0 ft,(Roof Load) DESIGN SUMMARY Design OK Maximum Bending Stress Ratio = 0.7751 1 Maximum Shear Stress Ratio = 0.242 : 1 Section used for this span 2x12 Section used for this span 2x12 fb:Actual = 922.34 psi fv:Actual = 50.08 psi FB:Allowable = 1,190.25 psi Fv:Allowable = 207.00 psi Load Combination +D+S+H Load Combination +D+S+ H Location of maximum on span = 7.625ft Location of maximum on span = 0.000 ft Span#where maximum occurs = Span#1 Span#where maximum occurs = Span#1 Maximum Deflection Max Downward Transient Deflection 0.215 in Ratio= 851 >=240 Max Upward Transient Deflection 0.000 in Ratio= 0<240 Max Downward Total Deflection 0.360 in Ratio= 508>=180 Max Upward Total Deflection 0.000 in Ratio= 0<180 Maximum Forces&Stresses for Load Combinations Load Combination Max Stress Ratios Moment Values Shear Values Segment Length Span# M V Cd C FN C i Cr Cm C t C L M fb F'b V N F'v +D+H 0.00 0.00 0.00 0.00 Length=15.250 ft 1 0.398 0.124 0.90 1.000 1.00 1.15 1.00 1.00 1.00 0.98 371.08 931.50 0.23 20.15 162.00 +D+L+H 1.000 1.00 1.15 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length=15.250 ft 1 0.359 0.112 1.00 1.000 1.00 1.15 1.00 1.00 1.00 0.98 371.08 1035.00 0.23 20.15 180.00 +D+Lr+H 1.000 1.00 1.15 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length=15.250 ft 1 0.287 0.090 1.25 1.000 1.00 1.15 1.00 1.00 1.00 0.98 371.08 1293.75 0.23 20.15 225.00 +D+5+H 1.000 1.00 1.15 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length=15.250 ft 1 0.775 0.242 1.15 1.000 1.00 1.15 1.00 1.00 1.00 2.43 922.34 1190.25 0.56 50.08 207.00 +D+0.750Lr+0.750L+H 1.000 1.00 1.15 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length=15.250 ft 1 0.287 0.090 1.25 1.000 1.00 1.15 1.00 1.00 1.00 0.98 371.08 1293.75 0.23 20.15 225.00 ' • • 0 , Title Block Line 1 Project Title: You can change this area Engineer: using the"Settings"menu item Project ID: and then using the"Printing& Project Descr: Title Block"selection. Title Block Line 6 Printed:30 MAY 2019, 8 14AM Wood Beam File=N:\PROJ10R3H3D-E1AW7PH9-K\ETOKQP-J\Byron Enerealc.ec6 . Software copyright ENERCALC,INC.1983-2019,Build:10.19.1.30 t_rc # KvV416007744 EPIC ENGINEERING,PC DESCRIPTION: RJ-1 Load Combination Max Stress Ratios Moment Values Shear Values Segment Length Span# M V Cd GEN C i Cr Cm C t CL M fb F'b V fv F'v +D+0.750L+0.750S+H 1.000 1.00 1.15 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length=15.250 ft 1 0.659 0.206 1.15 1.000 1.00 1.15 1.00 1.00 1.00 2.07 784.52 1190.25 0.48 42.60 207.00 +D+0.60W+H 1.000 1.00 1.15 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length=15.250 ft 1 0.224 0.070 1.60 1.000 1.00 1.15 1.00 1.00 1.00 0.98 371.08 1656.00 0.23 20.15 288.00 +D+0.70E+H 1.000 1.00 1.15 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length=15.250 ft 1 0.224 0.070 1.60 1.000 1.00 1.15 1.00 1.00 1.00 0.98 371.08 1656.00 0.23 20.15 288.00 +D+0.750Lr+0.750L+0.450W+H 1.000 1.00 1.15 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length=15.250 ft 1 0.224 0.070 1.60 1.000 1.00 1.15 1.00 1.00 1.00 0.98 371.08 1656.00 0.23 20.15 288.00 +D+0.750L+0.7505+0.450W4l 1.000 1.00 1.15 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length=15.250 ft 1 0.474 0.148 1.60 1.000 1.00 1.15 1.00 1.00 1.00 2.07 784.52 1656.00 0.48 42.60 288.00 +D+0.750L+0.750S+0.5250E+H 1.000 1.00 1.15 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length=15.250 ft 1 0.474 0.148 1.60 1.000 1.00 1.15 1.00 1.00 1.00 2.07 784.52 1656.00 0.48 42.60 288.00 +0.60D+0.60W+0.60H 1.000 1.00 1.15 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length=15.250 ft 1 0.134 0.042 1.60 1.000 1.00 1.15 1.00 1.00 1.00 0.59 222.65 1656.00 0.14 12.09 288.00 +0.60D+0.70E+0.60H 1.000 1.00 1.15 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length=15.250 ft 1 0.134 0.042 1.60 1.000 1.00 1.15 1.00 1.00 1.00 0.59 222.65 1656.00 0.14 12.09 288.00 Overall Maximum Deflections Load Combination Span Max.""Defl Location in Span Load Combination Max."+"Defl Location in Span +D+S+H 1 0.3596 7.681 0.0000 0.000 Vertical Reactions Support notation:Far left is#1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 0.638 0.638 Overall MINimum 0.381 0.381 +D+H 0.257 0.257 +D+L+H 0.257 0.257 +D+Lr+H 0.257 0.257 +D+S+H 0.638 0.638 +D+0.750Lr+0.750L+H 0.257 0.257 +D+0.750L+0.750S+H 0.543 0.543 +D+0.60W+H 0.257 0.257 +D+0.70E+H 0.257 0.257 +D+0.750Lr+0.750L+0.450W+H 0.257 0.257 +D+0.750L+0.750S+0.450W+H 0.543 0.543 +D+0.750L+0.750S+0.5250E+H 0.543 0.543 +0.60D+0.60W+0.60H 0.154 0.154 +0.60D+0.70E+0.60H 0.154 0.154 D Only 0.257 0.257 Lr Only L Only S Only 0.381 0,381 W Only E Only H€Only e 0 SOLAR'S MOST TRUSTED II!) R E C ....1 REE 1 1 . N_IDEAK BLACK ; • 1 1 . 1 5ERIE5 1 , 1 ; 1 , ; PREMIUM FULL BLACK MONO , 1 . , N-TYPE SOLAR PANELS WITH . SUPERIOR PERFORMANCE . . , , I L1.4 I o • : • 1 ! . MONO N-TYPE:THE NO LIGHT INDUCED i I MOST EFFICIENT C-SI DEGRADATION TECHNOLOGY i , , , • , , , 1 1 1 1 1 1 (-) S. 41OR . • ' 1 , 1 1 1 1 i * he 4111111 i ' 1 I 1 r , i 1 1 ' , , , , 1 , 1 1 ! ' , , , 1 ' 1 , , , , , , , , I . , I , , i 1 , 1 t , , SUPER STRONG FLEXIBLE FRAME UP TO 7000 PA INSTALLATION SNOW LOAD OPTIONS , , i 1 , 1 • , ; , , , • ' ° • 4 ._...‘9. ''. .%>/... . .: IMPROVED GUARANTEED HIGH PERFORMANCE IN POWER OVER LIFETIME SHADED CONDITIONS • 1 I ; I i ; 1 ; ' 11 ' 325 VV POWERATV OF TIGARD il i ' ill 11 ! , --)ING DIVISIO 20 YEAR PRODUCT WARRANTY ANNUAL DEGRADATION OVER ' 0.57o 25-YEAR POWER WARRANTY Y ' , 1675±2.5[65.94±0.1] GENERAL DATA ► 28[1.11 910[35.81 382.5[15.05] A , Cell type: 120 halfcut n typemonocSicells !�h`1000[39] + 6 strings of 20 cells in series Glass: 0.13"(3.2 mm)solar glass with anti-reflection surface treatment Backsheet: Highly reflective and resistant polymeric construction(black) a -H Frame: Anodized aluminum(black) tri OTi +i a, a Junction box: 3-part.3 bypass diodes,IP67rated v} N - in accordance withlEC62790 * o a Cable: 12AWG(4mm2)PVwire,39+47"(1m+1.2m) 11±0.2 in accordancew ith EN 50618 (0.43±0.8] Connectors: Staubli MC4 PV-KBT4/KST4,12AWG(4 mm2) in accordance with IEC 62852 n 20.5±0.5(1 j IP58onlywhenconnected [0.78±0.08] 1200[47] - Origin: Made in Singapore N. I] I -, °' -, `. „ ,L p MECHANICAL DATA ►--e--45[1.5] 22.5[0.9] _ 600±1[23.6±0.04] ® Dimensions: 65.9 x 39.25 x1.1"(1675 x 997 x 30 ram) Area:1. 17.98ft2(1.67m2) :_ -_ _�__- .;_-_ ,___ 30[1.78] Measurements in mm[in] i Weight: 39.7 lbs(18 kg) ELECTRICAL DATA @ STC Product code:RECxxxNP BLACK Nominal Power-PMPP(Wp) 310 315 320 325 Operational temperature: -40 ..+85°C Watt Class Sorting-(W) -01+5 -0/+5 -0/+5 -0/+5 Maximum system voltage: 1000 V Nominal Power Voltage-VMP,M 33.6 33.9 34.2 34.4 Design load(+):snow 4666 Pa(97.5 lbs/ft2)° Nominal Power Current-I (A) 9.24 9.31 9.37 9.46 Maximum test load(+): 7000 Pa(146 lbs/ft2)* Open Circuit Voltage-Voc(V) 40.2 40.5 40.8 41.0 Design load(-):wind 1600 Pa(33.4 lbs/ft2)' Short Circuit Current-l„(A) 10.01 10.09 10.18 10.27 Maximumtestload O: 2400 Pa(50(bs/ft2}* °; Max series fuse rating: 25A Y(%) 18.6 18.9 19.2 19.5 Panel Efficient E Max reverse current: 25A Values at standard test conditions(STC:air mass AM 1.5,irradiance1000 W/m°,temperature 2?C).based on a production spreadwitha g tolerance ofVcc&Isc+3%within onewattclass.*Wherexxx indicates the nominal powerciass P,,,,,,,)at SIC abo e. Calculated using a safety factor of]5 *See installation manual for mounting instructions t -5 ELECTRICAL DATA @ NOCT Product code*:RECxxxNP BLACK1===a1111011111.111111 t'' 2 Nominal Power-PMPPp)(W 234 238 241 245 Nominal Operating Cell Temperature: 44°C(±2T) NominalPowerVoltage-VMP,(V) 31.1 31.4 31.7 31.9 Temperature coefficient ofPM„P: -0.35%/°C Nominal Power Current-IM,P(A) 7.51 7.56 7.62 7.69 Temperature coefficient of Voc: -0.27%/°C OpenCircuitVoltage-Voc(V) 37.3 37.5 37.8 38.0 Temperature coefficient of 1„: 0.04%/°C v; Short Circuit Current-Isc(A) 8.01 8.07 8.14 8.22 *The temperature coefficients stated are linear values Nominal operating cell temperature(NOCT:a irmass AM 1.5,irradiance 800 W/m',temperature 20'C,w indspeed 1 m/s). *Where xxx indicates the nominal power class(P,,,'P)at STC above. `ERTIFICATIONS WARRANTY LOW LIGHTBEHAVIOUR �` , a c ��us l` E 0/e 20 year product warranty Typical low irradiance performance of module at STC.25year[inearpoweroutputwarranty,maximum degressionperformanceof0.5% a giving Pending:UL 1703(Fire type 2):IEC 61215,IEC 61730,!EC 62804(PID), g P• t, IEC 61701(Salt Mist),IEC 62716(Ammonia), 86%at end of ye a r 25. - 1509001:2015,15014001:2004,OHSAS18001:2007 See warranty conditions for further details. �• I m la1., _.._. _. W. Irradiance(W/m') Founded in Norway in 1996,REC is a leading vertically integrated solar energy company.Through integrated manufacturing from silicon to wafers,cells, high-quality panels and extending to solar solutions,REC provides the world with a reliable source of clean energy. REC's renowned product quality is ^ supported by the lowest warranty claims rate in the industry. REC is a Bluestar Elkem company with headquarters in Norway and operational RE headquarters in Singapore.REC employs more than 2,000 people worldwide,producing 1.5 GW of solar panels annually. www.recgroup.com , Data Sheet Enphase Microinverters Region: US Enphase The high-powered smart grid-ready Enphase IQ 7 Micro" and Enphase IQ 7+ MicroTM IQ 7 and IQ 7+ dramatically simplify the installation process while achieving the highest system efficiency. Microinverters Part of the Enphase IQ System,the IQ 7 and IQ 7+ Microinverters integrate seamlessly with the Enphase IQ Envoy"", Enphase Q AggregatorTM, Enphase IQ Battery1N, and the Enphase Enlighten1M monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Easy to Install • Lightweight and simple • Faster installation with improved,lighter two-wire cabling • Built-in rapid shutdown compliant(NEC 2014&2017) Productive and Reliable • Optimized for high powered 60-cell and 72-cell*modules • More than a million hours of testing • Class II double-insulated enclosure , - • UL listed ENPHASE n !Q a. =moi Mme' Smart Grid Ready { hENT h • Complies with advanced grid support,voltage and II{{ f t' frequency ride-through requirements • Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) The IQ 7+Micro is required to support 72-cell modules. CERTIFIED SAFETY US CA E341165 ENPHASE. E, To learn more about Enphase offerings,visit enphase.com a • Enphase IQ 7 and IQ 7+ Microinverters INPUT DATA(DC) IQ7-60-2-US IQ7PLUS-72-2-US Commonly used module pairings' 235 W-350 W+ 235 W-440 W+ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48 V 60 V Peak power tracking voltage 27 V-37 V 27 V-45 V Operating range 16 V-48 V 16 V-60 V Min/Max start voltage 22 V/48 V 22 V/60 V Max DC short circuit current(module Ise) 15 A 15 A Overvoltage class DC port II II DC port backfeed current 0 A 0 A PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA Nominal(L-L)voltage/range 240 V/ 208 V/ 240 V/ 208 V/ 211-264 V 183-229 V 211-264 V 183-229 V Maximum continuous output current 1.0 A 1.15 A 1.21 A 1.39 A Nominal frequency 60 Hz 60 Hz Extended frequency range 47-68 Hz 47-68 Hz AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A(L-L)branch circuit' 16(240 VAC) 13(240 VAC) 13(208 VAC) 11 (208 VAC) Overvoltage class AC port III III AC port backfeed current 0 A 0 A Power factor setting 1.0 1.0 Power factor(adjustable) 0.7 leading...0.7 lagging 0.7 leading...0.7 lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak CEC efficiency 97.6% 97.6% 97.5% 97.3% CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% MECHANICAL DATA IQ 7 Microinverter Ambient temperature range -40°C to+65°C Relative humidity range 4%to 100%(condensing) Connector type MC4(or Amphenol H4 UTX with additional Q-DCC-5 adapter) Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) Weight 1.08 kg(2.38 lbs) Cooling Natural convection-No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor FEATURES Communication Power Line Communication(PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according manufacturer's instructions. 1.No enforced DC/AC ratio.See the compatibility calculator athttps://enphase.com/en-us/support/module-compatibility. 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings,visit enphase.com v EN PHAS E, ©2018 Enphase Energy.All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc. 2018-02-08 CERTIFICATE OF COMPLIANCE Certificate Number 20180530-E341165 Report Reference E341165-20171030 Issue Date 2018-MAY-30 Issued to: ENPHASE ENERGY INC 1420 N McDowell Blvd Petaluma CA 94954-6515 This is to certify that STATIC INVERTERS, CONVERTERS AND representative samples of ACCESSORIES FOR USE IN INDEPENDENT POWER SYSTEMS; PHOTOVOLTAIC RAPID SHUTDOWN SYSTEM EQUIPMENT See Addendum Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate. Standard(s)for Safety: See Addendum Additional Information: See the UL Online Certifications Directory at www.ul.com/database for additional information Only those products bearing the UL Certification Mark should be considered as being covered by UL's Certification and Follow-Up Service. Look for the UL Certification Mark on the product. S (111) Bruce Mahrenholz,Director North American Certification Program UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC(UL)or any authorized licensee of UL.For questions,please contact a local UL Customer Service Representative at http://ul.com/aboutul/bcations/ Page 1 of 2 Created by UL DaL.ument Assembler 201E-07-05 15:07:07 -05:00 t , CERTIFICATE OF COMPLIANCE Certificate Number 20180530-E341165 Report Reference E341165-20171030 Issue Date 2018-MAY-30 This is to certify that representative samples of the product as specified on this certificate were tested according to the current UL requirements. Permanently-connected, Grid Support utility Interactive, 208V single-phase, 240V single phase evaluated for use on a split phase system, distributed resource power system. Models IQ7-60, IQ7PLUS-72, and IQ7X-96,followed by-2, -5, -B, or-ACM,followed by-US+. Models IQ7PD-72-2-US and IQ7PD-84-2-US. USL/CNL—Photovoltaic Rapid Shutdown Equipment. Models IQ7-60, IQ7PLUS-72, and IQ7X-96,followed by-2, -5, -B, or-ACM,followed by-US+. Models IQ7PD-72-2-US and IQ7PD-84-2-US. + may be followed by additional characters not affecting safety Standard(s)for Safety: UL 62109-1, SAFETY OF POWER CONVERTERS FOR USE IN PHOTOVOLTAIC POWER SYSTEMS-PART 1: GENERAL REQUIREMENTS CSA C22.2 NO. 107.1-01, GENERAL USE POWER SUPPLIES IEEE 1547 INTERCONNECTING DISTRIBUTED RESOURCES WITH ELECTRIC POWER SYSTEMS IEEE 1547.1 IEEE STANDARD CONFORMANCE TEST PROCEDURES FOR EQUIPMENT INTERCONNECTING DISTRIBUTED RESOURCES WITH ELECTRIC POWER SYSTEMS UL 1741, INVERTERS, CONVERTERS, CONTROLLERS AND INTERCONNECTION SYSTEM EQUIPMENT FOR USE WITH DISTRIBUTED ENERGY RESOURCES CEC-300-2011-005,-CMF GUIDELINES FOR CALIFORNIA'S SOLAR ELECTRIC INCENTIVE PROGRAMS PURSUANT TO SENATE BILL 1 Bruce Mahrenholz,Director North American Certification Program UL LLC (11) Any information and documentation involving UL Mark services are provided on behalf of UL LLC(UL)or any authorized licensee of UL.For questions,please contact a local UL Customer Service Representative at httpJ/ul.com/aboutul/locationsi Page 2 of 2 Created by UL Document Assembler 2018-37-05 15:07.07 -05.00 Calculating AC Line Voltage Rise for IQ-Series Micros with Q Cable IQ 7: Table 1.7:Internal Q Cable VRise (IQ 7-240V/Portrait Cable, Q-12-10-240) IQ 7 Microinverters per branch 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 VRise(V) 0.02 0.05 0.10 0.17 0.25 0.35 0.47 0.61 0.76 0.93 1.11 1.32 1.54 1.77 2.03 2.30 VRise(%) 0.01 0.02 0.04 0.07 0.11 0.15 0.20 0.25 0.32 0.39 0.46 0.55 0.64 0.74 0.84 0.96 Current(A) 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 15.0 16.0 Table 1.8:Internal Q Cable VRise(IQ 7-24011/Landscape 60-Cell Cable, Q-12-17-240) IQ 7 Microinverters per branch 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 VRise(V) 0.03 0.08 0.16 0.26 0.39 0.55 0.73 0.94 1.17 1.43 1.71 2.03 2.36 2.73 3.12 3.53 VRise(%) 0.01 0.03 0.06 0.11 0.16 0.23 0.30 0.39 0.49 0.60 0.71 0.84 0.99 1.14 1.30 1.47 Current(A) 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 15.0 16.0 Table 1.9:Internal Q Cable VRise(IQ 7-240V/Landscape 72-Cell Cable*, Q-12-20-200) IQ 7 Microinverters per branch 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 VRise(V) 0.03 0.09 0.18 0.30 0.45 0.63 0.84 1.08 1.34 1.64 1.97 2.33 2.72 3.14 3.59 4.06 VRise(%) 0.01 0.04 0.07 0.12 0.19 0.26 0.35 0.45 0.56 0.68 0.82 0.97 1.13 1.31 1.49 1.69 Current(A) 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 15.0 16.0 *Note that IQ 7 Micros are compatible with 60-cell PV modules only,but can be used with Q-12-20-200 cable. 12 ©2018 Enphase Energy Inc All rights reserved January 2018 Data Sheet Enphase Networking Enphase The Enphase IQ Combiner 3TM with Enphase IQ EnvoyTM consolidates interconnection IQ Combiner 3 equipment into a single enclosure and (X-IQ-AM1-240-3) streamlines PV and storage installations by providing a consistent, pre-wired solution for residential applications. It offers up to four 2-pole input circuits and Eaton BR series busbar assembly. Smart • Includes IQ Envoy for communication /,. and co _ ▪ Flexible netntrol working supports Wi-Fi, ei ® , w,e, Ethernet,or cellular g • Optional AC receptacle available for PLC bridge -- tf t 7 i • Provides production metering and optional I consumption monitoring ' 1 :.•' ' ' '14tg`' -- ' Vi., i ,it'r P Simple „, =r=" - 1 . • Reduced size from previous combiner ., „ • Centered mounting brackets support single '' 4 stud mounting • Supports back and side conduit entry • Up to four 2-pole branch circuits for 240 VAC ,- plug-in breakers(not included) • 80 A total PV or storage branch circuits Reliable • Durable NRTL-certified NEMA type 3R enclosure 41)1 • Five-year warranty • UL listed LISTED E N P H A S E To learn more about Enphase offerings,visit enphase.com N.." Enphase IQ Combiner 3 MODEL NUMBER IQ Combiner 3 X-IQ-AM1-240-3 IQ Combiner 3 with Enphase IQ Envoy'printed circuit board for integrated revenue grade PV production metering(ANSI C12.20+/-0.5%)and optional*consumption monitoring(+/-2.5%). ACCESSORIES and REPLACEMENT PARTS(not included,order separately) Enphase Mobile Connect" CELLMODEM-03(4G/12-year data plan) Plug and play industrial grade cellular modem with data plan for systems up to 60 CELLMODEM-01 (3G/5-year data plan) microinverters,(Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin Islands, CELLMODEM-M1 (4G based LTE-M/5-year data plan) where there is adequate cellular service in the installation area.) Consumption Monitoring*CT CT-200-SPLIT Split core current transformers enable whole home consumption metering(+/-2.5%). Circuit Breakers Supports Eaton BR210,BR215,BR220,BR230,BR240,BR250,and BR260 circuit breakers. BRK-10A-2-240 Circuit breaker,2 pole,10A,Eaton BR210 BRK-15A-2-240 Circuit breaker,2 pole,15A,Eaton BR215 BRK-20A-2P-240 Circuit breaker,2 pole,20A,Eaton BR220 EPLC-01 Power line carrier(communication bridge pair),quantity 2 XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 3(required for EPLC-01) XA-ENV-PCBA-3 Replacement IQ Envoy printed circuit board(PCB)for Combiner 3 ELECTRICAL SPECIFICATIONS Rating Continuous duty System voltage 120/240 VAC,60 Hz Eaton BR series busbar rating 125 A Max.continuous current rating(output to grid) 65 A Max.fuse/circuit rating(output) 90 A Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DG)breakers only(not included) Max.continuous current rating(input from PV) 64 A Max.total branch circuit breaker rating(input) 80A of distributed generation/90A with IQ Envoy breaker included Production Metering CT 200 A solid core pre-installed and wired to IQ Envoy MECHANICAL DATA Dimensions(WxHxD) 49.5 x 37.5 x 16.8 cm(19.5"x 14.75"x 6.63").Height is 21.06'(53.5 cm with mounting brackets). Weight 7.5 kg(16.5 lbs) Ambient temperature range -40°C to+46°C(-40°to 115°F) Cooling Natural convection,plus heat shield Enclosure environmental rating Outdoor,NRTL-certified,NEMA type 3R,polycarbonate construction Wire sizes • 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors • 60 A breaker branch input: 4 to 1/0 AWG copper conductors • Main lug combined output: 10 to 2/0 AWG copper conductors • Neutral and ground: 14 to 1/0 copper conductors Always follow local code requirements for conductor sizing. Altitude To 2000 meters(6,560 feet) INTERNET CONNECTION OPTIONS Integrated Wi-Fi 802.11b/g/n Ethernet Optional,802.3,Cat5E(or Cat 6)UTP Ethernet cable (not included) Cellular Optional,CELLMODEM-01 (3G)or CELLMODEM-03(4G) or CELLMODEM-M1 (4G based LTE-M) (not included) COMPLIANCE Compliance,Combiner UL 1741 CAN/CSA C22.2 No.107.1 47 CFR,Part 15,Class B,ICES 003 Production metering:ANSI C12.20 accuracy class 0.5(PV production) Compliance,IQ Envoy UL 60601-1/CANCSA 22.2 No.61010-1 *Consumption monitoring is required for Enphase Storage Systems. To learn more about Enphase offerings,visit enphase.com Cg.)2018 Enphase Energy All rights reserves.All trademarks or brands in this document are registered by their respective owner. ENPHASE, 2018-09-13 Data Sheet Enphase Networking Enphase IQ Envoy The Enphase IQ Envoy' communications gateway delivers solar production and energy consumption data to Enphase Enlighten" monitoring and analysis software for comprehensive, remote maintenance and management of the Enphase IQ System. With integrated revenue grade production metering and optional consumption monitoring,the Envoy IQ is the platform for total energy management and integrates with the Enphase IQ Battery' Smart ENPHASE • Enables web-based monitoring and control • Bidirectional communications for f remote upgrades Simple • Easy system configuration using • Enphase Installer Toolkit"'mobile app • Flexible networking with Wi-Fi, Ethernet,or cellular Reliable • Designed for installation indoors or outdoors • Five-year warranty LISTED ENPHASE To learn more about Enphase offerings,visit enphase.com ' . . . Enphase IQ Envoy MODEL NUMBERS Enphase IQ Envoy' Enphase IQ Envoy communications gateway with integrated revenue grade PV production ENV-IQ-AM1-240 metering(ANSI C12.20+/-0.5%)and optional consumption monitoring(+/-2.5%). wccsmmon|sm��e,xopam�k4 Enphase Mobile Connect" Plug and play industrial grade cellular modem with five-year data plan for systems up to 60 nsumoosm'01 (3G) m|ommvenem.(Available in the US,Canada,mexico,Puerto Rico,and the US Virgin Islands, CELLMODEM-03(4G) where there is adequate cellular service in the installation area.) Consumption Monitoring CT Split-core current transformers enable whole home metering. CT-200-SPLIT POWER REQUIREMENTS Power requirements ----- 120/240 VAC s --------- — - Max 20 A overcurrent protection required. CAPACITY _-_- Number of microinverters polled Up to 600 MECHANICAL DATA Weight 17.6 oz(498 g) Ambient temperature range -40°m65°n(-40°m149`F) ~m~m«o'CF4n`mn5°Rifinstalled inanenclosure Environmental rating lP3O.For installation indoors or in art NRTL-certified,NEMA type 3R enclosure. Altitude To 2000 meters(6,560 feet) INTERNET CONNECTION Integrated -- -- ---- --- -------- Ethernet 802.3,Cat5E(or Cat 6)UTP Ethernet cable,not included Mobile Optional,CELLMODEM-01 (3G)or CELLMODEM-03(4G), not included COMPLIANCE Compliance UL 916 CAN/CSA C22.2 No.61010-1 47 CFR,Part 15,Class B,ICES 003 IEC/EN 61010-1:2010, sw50065-1.sm61000-4-5,cw61000'6-1'sw61000'6-2 Metering:ANSI C12.20 accuracy class 0.5 To earn more about Enphase offerings,visit enphase.com '&m//mp»amme/o'.All rights reserved All trademarks"/brands used are the property ofc"r»uveEnergy,Inc ENPHASE FLASHED PV ROOF-MOUNT COMEUNER/ENCLOSURE Basic Features • Stamped Seamless Construction • 18 Gauge Galvanized Steel • Powder Coated Surfaces "' • Flashes into the roof deck • 3 Roof deck knockouts .5", .75", 1" • 5 Centering dimples for entry/exit fittings or conduit • 2 Position Ground lug installed • Mounting Hardware Included SolaDeck Model SD 0783 SolaDeck UL50 Type 3R Enclosures Available Models: Model SD 0783-(3"fixed Din Rail) �' x Model SD 0786-(6"slotted Din Rail) SolaDeck UL 1741 Combiner/Enclosures Models SD 0783-41 and SD 0786-41 are labeled and ETL listed UL STD 1741 according to the UL STD 1741 for photovoltaic combiner enclosures. Max Rated-600VDC, 120AMPS Model SD 0783-41 3" Fixed Din Rail fastened using Norlock System **Typical System Configuration .. .; 4-Din Rail Mounted Fuse Holders 600VDC 30 AMP 1-Power Distribution Block 600VDC 175AMP 1-Bus Bar with UL lug Model SD 0786-41 6"Slotted Din Rail fastened using steel studs **Typical System Configuration 4-Din Rail Mounted Fuse Holders 600VDC 30 AMP 4-Din Rail Mounted Terminal Blocks Bus Bars with UL lug **Fuse holders and terminal blocks added in the field must be UL listed or recognized and meet 600 VDC 30 AMP ,172-44 si 1100 for fuse holders,600V 50 AMP 90C for rail mounted terminal blocks 1 and 600 V 175 AMP 90C for Power Distribution Blocks. Use Copper Wire -} _'- Conductors. Cover is trimmed to allow Model SD 0783-41,wired with Model SD 0786-41,wired with conduit or fittings, base is Din Rail mounted fuse holders, Din Rail mounted fuse holders, center dimpled for fitting bus bar and power distribution terminal blocks and bus bars. locations. block. RSTC Enterprises, Inc • 2219 Heimstead Road •Eau Cliare, WI 54703 For product information call 1(866) 367-7782 n u Component Details ral Component 0 CERTII: D CCFTIFIEDCERTIFIED / �' ML �� ML '- ML -...,„<„,„:„._____„7-, "--.o -, N.,.'-,--; 4 0 1..4.•0..fr. .00.-7_,,„>n) \ , Com/ `\\Is. V,I III --- // �y / VVV \. .\. Composition Roof Attachment Tile Replacement Roof Attachment Flat Tile Roof Attachment Roof attachment kit for composition Roof attachment kit for flat, S,and Roof attachment kit for flat tile shingle roofs including L foot, W tile roofs including base, riser,tile roofs including tile hook and umbrella lag screw,flashing,and replacement flashing, L foot, and hardware hardware hardware ice. \\-, �.C�.TIFIED \� \ : CERTIFIED �ii \ CERTIFIED ) ML ll\\ ML 2,,,,,,,_„---„,---/' / ML � Metal Roof Base Attachment Seam Clamp Roof Attachment Ultra Rail Mounting Hardware Roof attachment kit for flat metal Roof attachment for standing seam Hardware kit for attaching Ultra Rail roofs including metal roof base, L metal roofs including seam clamp, L to any roof attachment that uses an foot, and hardware foot,and hardware L foot or other slotted mount that accepts 5/16" hardware 0 0 /�1 ,:�f 0Q. CERTIFIED CERTIFIED / "� f CERTIFIED ML,G/B ML,G/B % � i/ '- ®� ML,G/B UR-40 Rail Ultra Rail Splice Mid Clamp UR-40 rail for Ultra Rail roof mount Rail splice component including two Top-down module mid clamp racking system splice halves and hardware including clamp and hardware UL Listing Legend: ML-Evaluated for Mechanical Loading 5 G/B-Evaluated for Grounding/Bonding Component Details AY CERTIFIED CERTIFIED v _- j, ----, te,. ML,G/B ML /i'� � �. ,,,,-5•-i'____*-� \ice' i </ Adjustable End Clamp Universal End Clamp Universal Wire Clamp Top-down module end clamp Bottom-mount module end clamp Wire management component used including clamp and hardware including clamp and hardware to secure conductors between rails „r CE:RTIfIED CERTIFIED �$, �� G/B /i/ G/B 01Pg‘II 4 I I I 1 li I 1/4 4 I I I I P P'1 4 ''"es"'"**''''' 1 1 N''',„,\j ---'' s ,--- Wire Retention Clip MLPE Rail Attachment Kit MLPE Frame Attachment Kit Wire management component used Rail attachment for module level Module frame attachment for to secure conductors in rails power electronics like microinverters module level power electronics like and optimizers microinverters and optimizers Aesthe:icComponents CERTIFIED CERTIFIED G B l V �\ / G/B -.44Nri'-: ' y� 14t4 SNP SnapNrack Ground Lug Ilsco Lay-In Lug - GBL-4DBT UR-40 Rail End Cap Plastic end cap for UR-40 Rail C) UL Listing Legend: ML-Evaluated for Mechanical Loading 6 G/B-Evaluated for Grounding/Bonding • 1 1 DESCRIPTION: DRAWN BY: SNAPNRACK, ULTRA RAIL COMP KIT mwatkins SQpN rack- REVISION: Solar Mounting Solutio PART NUMBER(S): B 595 MARKET STREET,29TH FLOOR•SAN FRANCISCO,CA 94105 USA SEE BELOW PHONE(415)590-6900•FAX(415)580-6902 I TME INFORMATION IN THIS DRAWING 19 CONFlDENTIPL ANO PROPRIETARY.ANY REPROWCTON,DISCLOSURE.OR USE THEREOF IS PROHIBITED WITHOIR THE WRITTEN CONSENT OF SUNRUN SOUTH LLC. cam* I* oiro 4 1 o o u u u u u 0 ll�llllll 2 � 3 k'-- o o 0 PARTS LIST ITEM QTY PART NUMBER DESCRIPTION 1 1 242-92266 SNAPNRACK, UMBRELLA LAG, TYPE 3, 4IN, SS 2 1 242-01219, 242-01220 SNAPNRACK, ULTRA FOOT FOR U FLASHING, SILVER/ BLACK 3 1 232-01375, 232-01376 SNAPNRACK, COMP FLASHING, 9IN X 12IN, SILVER/ BLACK ALUM MATERIALS: 6000 SERIES ALUMINUM, STAINLESS STEEL, RUBBER DESIGN LOAD (LBS): 405 UP, 788 DOWN, 236 SIDE ULTIMATE LOAD (LBS): 2006 UP, 4000 DOWN, 1070 SIDE TORQUE SPECIFICATION: 12 LB-FT CERTIFICATION: UL 2703, FILE E359313 i WEIGHT (LBS.1: 0,80_ DESCRIPTION: DRAWN BY: SNAPNRACK, BONDING MID CLAMP D.Ryan SapNac"' c REVISION: Solar Mounting Solutions PART NUMBER(S): 242-02050, 242-02051, 242-02052, 242-02053, /q595 MARKET STREET,29TH FLOOR•SAN FRANCISCO,CA 94105 USA PHONE(415)5806900•FAX(415)580-6902 242-02054 242-02055 242-02056 242-02057 THEINFORTON INLOSUREORUSETHEFIEON,�ANORRO�NE,IOUTTI. 7 ! 1 REPROWCl10N,WRITTEN CONSE TO THEREOFS PROHISREO1IIIgOIIf TIE WRRTEN CONSENT OF SUNRUN SOUTH LLC. ___ lb il I°'1 lir r ..Z(C ? '' , II 0 .*s--- ______-____k-:_a,,v A ,,,,_.,., .,______, Mii-----..... .... 0 U ,,,:,.„ ,„%-r-Lt_--. I .4,,,,y)� ,...,_ 4...,,,,... .. „....: ,,,.. 0 0 c) t 2...... 1 W------1 44' 0 ) 0.,,L.__ ..\,,,,,,,,.. ,%........___.___-f. ..d d Nill%PP 0• 4,-,), „____4 ,o, , Q ___ PARTS LIST ITEM QTY DESCRIPTION a 1 II 5/16IN-18 SS HCS BOLT, LENGTH VARIES, CLEAR/ BLACK 2 5/16IN SS SPLIT LOCK WASHER, CLEAR/ BLACK 3 Q SNAPNRACK, BONDING MID CLAMP, CLEAR/ BLACK 4 1 SNAPNRACK, BONDING CHANNEL NUT 5 1 SNAPNRACK, MID CLAMP SPRING, SS MATERIALS: 6000 SERIES ALUMINUM, STAINLESS STEEL OPTIONS: DESIGN LOAD (LBS): 800 CLEAR/ BLACK ANODIZED ULTIMATE LOAD (LBS): 2400 TORQUE SPECIFICATION: 10+ LB-FT CERTIFICATION: UL 2703, FILE E359313 WFT(;HT (I RS)• Il 16 - 0 jR , DESCRIPTION: DRAWN BY: SNAPNRACK, ULTRA RAIL SPLICE mwatkins Sccyl\ mc REVISION: PART NUMBER(S): 595 MARKET STREET,29TH FLOOR•SAN FRANCISCO,CA 94105 USA A PHONE(415)5806900•FAX(415)580-6902 242-01213, 242-01214 THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY.ANY '- REPRODUCTION.DISCLOSURE,OR USE THEREOF IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF SUNRUN SOUTH LLC. ) 1 4 fh#- 0 919 0 04"regoi," 0100 0,, R. 0 4 O ate" , (F,A,2 ITEM QTY DESZ:k1N I TON ._._ _.— 1 1 SNAPNRACK ULTRA RAIL SPLICE TAPPED PRC, CLEAR 2 1 SNAPNRACK ULTRA RAIL SPLICE THRU PRC, CLEAR 3 2 SNAPNRACK, SNAPLINK BONDING CLIP, TYPE 2, STEEL 4 1 BOLT, FLANGE, SERRATED, 5/16IN-18 X 1-3/4IN, SS MATERIALS: 6000 SERIES ALUMINUM, STAINLESS STEEL OPTIONS: DESIGN LOAD (LBS): N/A CLEAR/ BLACK ANODIZED ULTIMATE LOAD (LBS): N/A TORQUE SPECIFICATION: 12 LB-FT CERTIFICATION: UL 2703, FILE E359313 WEIGHT (LBS): n c7 I II ' , Y S DESCRIPTION: DRAWN BY: SNAPNRACK, UNIVERSAL END CLAMP D.Ryan SQpT - REVISION: Solar Mountin .. . tions PART NUMBER(S): 242-02215 5 MARKET STREET,29TH FLOOR•SAN FRANCISCO,CA 94105 USA Al,Y` PHONE(415)580-6900•FAX(415)590-6902 THE INFORMST1ON IN THIS DRAWING M CONFIDENTULLANU PROPRIETARY.ANY - - REPRODUCDON,DISCLOSURE,OR USE THEREOF ISREDYRl/10UT ThE WRITTEN CONSENT OF SUNRUN SOUTH SOUTH LLC. �� /1° O 4-, IIIIIIIII 4K 41100.-#111114---". J �11111\lll0 to 0 0 PARTS LIST -- -- ITEM QTY DESCRIPTION 1 1 SNAPNRACK END CLAMP UNIVERSAL WAVE 2 1 SNAPNRACK, UNIVERSAL END CLAMP WEDGE 3 1 5/16IN X 3/4IN SS FLAT WASHER 4 1 BOLT, HEX CAP, 5/16IN-18 X 1-1/2IN, SS 5 1 SNAPNRACK UEC PULL STRAP MATERIALS: 6000 SERIES ALUMINUM, STAINLESS STEEL OPTIONS: DESIGN LOAD (LBS): 800 ULTIMATE LOAD (LBS): 2400 TORQUE SPECIFICATION: 10+ LB-FT CERTIFICATION: UL 2703, FILE E359313 WEIGHTjLBS): 0.24 AURIC SOLAR LLC 2310 SOUTH 1300 WEST SALT LAKE CITY UT 84119 CCB LICENSE 212831 CONSTRUCTION CONTRACTORS BOARD a C= < a a POCKET CARD RESIDENTIAL BOND.$15, 0 LICENSE NUMBER:212831 4 4 4 4 4� 05 COMMERCIAL BOND $50,000 EXPIRATION DATE: 11/16/2020 fold and detach INSURANCE$1,000,000/$2,000,000 ENTITY TYPE:Limited Liability Company along INDEP CONT STATUS NONEXEMPT ENDORSEMENT(S):Residential Specialty Contractor and a RMI THANIEL SHAFFER BISHOP Commercial Specialty Contractor Level 1 perforation HOME INSPECTOR CERTIFIED NO AURIC SOLAR LLC 2310 SOUTH 1300 WEST 4 4 4 4 4 SALT LAKE CITY UT 84119 pV LICENSE CARDp V 4 4 4 STATE OF OREGON CONSTRUCTION CONTRACTORS BOARD LICENS\E CERTIFICATE LICENSE NUMBER: 212831 This document certifies that si AURIC SOLAR LLC 2310 SOUTH 1300 WEST SALT LAKE CITY UT 84119 is licensed in accordance with Oregon Law as a Residential Specialty Contractor and a Commercial Specialty Contractor Level 1 License Details: EXPIRATION DATE. 11/16/2020 ENTITY TYPE: Limited Liability Company INDEP. CONT STATUS NONEXEMPT RESIDENTIAL BOND $15,000 COMMERCIAL BOND $50,000 INSURANCE $1,000,000/$2,000,000 RMI THANIEL SHAFFER BISHOP HOME INSPECTOR CERTIFIED NO