Loading...
Report (33) MF:c._.25tq- o V tc\a- v&-,,,q . '- ,,, a • TRANE® Submittal OFFICE „ Prepared For: Date: September 19, 2018 HVAC Inc. Diane Gardner Job Name: Jaguar Land Rover Trane U.S. Inc. is pleased to provide the enclosed submittal for your review and approval. Product Summary Qty Product 5 Split System Air Conditioning Units (Small, 2.5-5 Tons) 1 Split System Air Conditioning Units (Large, 7.5 Tons) The attached information describes the equipment we propose to furnish for this project,and is submitted for your approval. Product performance and submittal data is valid for a period of 6 months from the date of submittal generation. If six months or more has elapsed Chris Smith between submittal generation and equipment release,the product Trane performance and submittal data will need to be verified. It is the 7257 SW Kable Lane customer's responsibility to obtain such verification. Portland, OR 97224-7181 Phone: (503)431-2561 Email: chrisp.smitha.trane.com olmommow- J:IJOBS1124170190141Ducted Split System Rev_ _doc . Table Of Contents Product Summary 1 i 2.5-5 Ton Split System Air Conditioning Units (Small) (Items CI -C4) Tag Data 3 Product Data 3 Performance Data 4 Mechanical Specifications 5 Unit Dimensions 7 Weight, Clearance&Rigging Diagram 22 Accessory 23 7.5 Ton Split System Air Conditioning Units, Indoor(Large) (Item B1) Tag Data 24 Product Data 24 Performance Data 24 Mechanical Specifications 25 Unit Dimensions 26 Weight, Clearance&Rigging Diagram 28 Field Wiring 29 7.5 Ton Split System Air Conditioning Units, Outdoor(Large) (Item C1) Tag Data 30 Product Data 30 Mechanical Specifications 31 Unit Dimensions 32 Weight, Clearance&Rigging Diagram 34 Accessory 3536 Field Wiring Field Installed Options-Part/Order Number Summary Split System Air Conditioning Units(Small) 38 Split System Air Conditioning Units(Large) 38 Mixing Box Cut Sheets 39 Jaguar Land Rover September 19,2018 Tag Data -Split System Air Conditioning Units (Small) (Qty: 5) Item Tag(s) Qty Description Model Number Cl SS-N-1 1 2.5 Ton Unitary Split 4TWR5030H1 TEM6A0B30H21S Systems (SSC) C2 SS-N-2 1 3 Ton Unitary Split 4TWR5036H1 TEM6A0C36H31S Systems (SSC) C3 SS-N-3, 2 2 Ton Unitary Split 4TWR6024H1 TEM6A0B24H21S SS-N-5 Systems (SSC) C4 SS-P-1 1 5 Ton Unitary Split 4TWR5060H1 TEM6A0C60H51S Systems (SSC) Product Dta -Split System Air Conditioning Units (Small) Item: Cl Qty: 1 Tag(s): SS-N-1 4TWR5 Heat Pump Outdoor Unit 2.5 Ton - Nominal Cooling Capacity 200-230 Volt 1 Phase 60 Hertz 2.5 Ton air handler Multi-poise 4-way High Efficiency Variable Speed 208-230/1/60 Standard Coil Brazed connections 10 kW Electric Htr w/Ckt Brk for 208/240V 1 Phase 60 Hz(Fld) Wired Thermostat(Fld) Item: C2 Qty: 1 Tag(s): SS-N-2 4TWR5 Heat Pump Outdoor Unit 3 Ton - Nominal Cooling Capacity 200-230 Volt 1 Phase 60 Hertz 3 Ton air handler Multi-poise 4-way High Efficiency Variable Speed 208-230/1/60 Standard Coil Brazed connections 8 kW Electric Heater for 208/240V 1 Phase 60 Hertz(Fld) Economizer(Mixing box) (Fld) Wired Thermostat(Fld) Item: C3 Qty: 2 Tag(s): SS-N-3, SS-N-5 4TWR6 Heat Pump Outdoor Unit 2 Ton - Nominal Cooling Capacity 200 -230 Volt 1 Phase 60 Hertz 2 Ton air handler Multi-poise 4-way High Efficiency Variable Speed 208-230/1/60 Standard Coil Brazed Connections 8 kW Electric Htr w/Ckt Brk for 208/240V 1 Phase 60 Hz(Fld) Economizer(Mixing box) (Fld) SS-N-3 only Wired Thermostat(Fld) Item: C4 Qty: 1 Tag(s): SS-P-1 4TWR5 Heat Pump Outdoor Unit 5 Ton - Nominal Cooling Capacity 200-230 Volt 1 Phase 60 Hertz 5 Ton air handler Multi-poise 4-way High Efficiency Variable Speed 208-230/1/60 Standard Coil FLD=Furnished by Trane U.S. Inc./Installed 1y Equipment¢ubmittal Page-3-of 42 Others Jaguar Land Rover September 19,2018 Brazed Connections 15 kW Electric Heater for 208/240V 1 Phase 60 Hertz (Fld) Economizer(Mixing box) (Fld) Wired Thermostat(Fld) Performance Data -Split System Air Conditioning Units (Small) Tags SS-N-1 SS-N-2 SS-N-3, SS-P-1 SS-N-5 Design clg EDB (F) 80.00 80.00 80.00 80.00 Design clg EWB (F) 67.00 67.00 67.00 67.00 Design clg outdoor DB (F) 95.00 95.00 95.00 95.00 Percentage of outdoor air-clg (%) 20.00 20.00 20.00 15.00 Cooling EDB (F) 76.60 76.60 76.60 75.40 Cooling EWB (F) 67.00 67.00 67.00 67.00 Rated gross capacity (AHRI) (Btuh) 29000.00 34800.00 24200.00 57500.00 Design clg outdoor WB (F) 67.00 67.00 67.00 67.00 Clg design space DB (F) 72.00 72.00 72.00 72.00 Clg design space WB (F) 67.00 67.00 67.00 67.00 Clg net total capacity(Btuh) 29686.00 35380.00 24307.00 59451.00 Clg net sensible capacity(Btuh) 19392.00 23170.00 15830.00 37143.00 Clg net latent capacity(Btuh) 10293.00 12209.00 8477.00 22307.00 Calc clg LDB (F) 59.10 58.50 58.60 59.20 Calc clg LWB (F) 57.80 57.40 57.40 58.10 SEER @ AHRI (btuh/watt) 15.25 15.00 16.00 15.00 EER @ AHRI (EER) 12.5 12.5 13.0 12.5 Cooling airflow(cfm) 1038 1194 821 2136 Min system airflow clg (cfm) 875 1050 700 1750 Max system airflow clg (cfm) 1125 1350 900 2250 Min system airflow htg (cfm) 875 1050 700 1750 Max system airflow htg (cfm) 1125 1350 900 2250 AHRI airflow (cfm) 905 1100 800 1770 AHRI reference number() 9033590 9126462 7562095 10034740 Compressor power @ (specific Ambient) (W) 1967.0 2401.0 1583.0 3888.0 Condenser fan power @ (specific SP) (W) 157.0 172.0 134.0 236.0 Supply fan power @ (specified SP) (W) 196.0 211.0 145.0 476.0 ASHRAE 90.1 S6.4.1 compliant Yes Yes Yes Yes Indoor MCA(A) 58.00 50.00 48.00 68.00 Indoor Max Fuse Size (A) 60.00 60.00 60.00 80.00 Outdoor MCA (A) 17.00 18.00 14.00 32.50 Indoor Max Fuse Size (A) 25.00 30.00 25.00 50.00 Htg outdoor DB (F) 17.00 17.00 17.00 17.00 Heating airflow(cfm) 950 1100 775 1800 Heating capacity @ 47F (Btuh) 27800.00 33000.00 22000.00 55000.00 COP @ AHRI 47F (with Air Handler) (COP (kW/kW)) 4.10 3.92 4.00 3.90 COP @ AHRI 17F (with Air Handler) (COP (kW/kW)) 2.70 2.78 2.60 2.70 Heating capacity @ 17F (Btuh) 17800.00 21000.00 14100.00 36200.00 HSPF @ AHRI (btuh/watt) 9.50 9.50 9.00 9.00 Heating EDB (F) 60.00 70.00 70.00 70.00 Htg system net capacity (Btuh) 18226.00 21058.00 14064.00 36307.00 Htg system LDB (F) 77.76 87.73 86.80 88.68 AHRI high compressor power heating mode (W) 1634.0 2084.0 1332.0 3420.0 AHRI low compressor paver heating mode (W) 1579.0 1830.0 1310.0 3216.0 AHRI condenser fan power heating mode (W) 157.0 172.0 134.0 236.0 AHRI supply fan power heating mode (W) 196.0 211.0 145.0 476.0 80 to 90 second blower off delay Required Required Required Required Electric heat capacity @ 208 Volts (Btuh) 24602.00 19688.00 19688.00 36851.00 Electric heat capacity @ 240 Volts (Btuh) 32757.00 26205.00 26205.00 49135.00 FLD=Furnished by Trane U.S. Inc./Installed by Equipment Submittal Page 4 of 42 Others Jaguar Land Rover September 19,2018 Mechanical Specifications -Split System Air Conditioning Units (Small) Item: Al -A4 Qty: 5 Tag(s): SS-N-1, SS-N-2, SS-N-3, SS-N-5, SS-P-1 General -4TWR5 The 4TWR5 is fully charged from the factory for up to 15 feet of piping. This unit is designed to operate at outdoor ambient temperatures as high as 115 F. Cooling capacities are matched with a wide selection of air handlers and furnace coils that are AHRI certified. The unit is certified to UL 1995. Exterior is designed for outdoor application. Casing -4TWR5 Unit casing is constructed of heavy gauge, G90 galvanized steel and painted with a weather-resistant powder painton all louvers, panels, prepaint on all other panels. Corrosion and weather-proof CMBP-G30 DuraTuff base. Refrigerant Controls -4TWR5 Refrigeration system controls include condenser fan and compressor contac-tor. High and low pressure controls are inherent to the compressor.A factory installed liquid line drier is standard. Compressor-4TWR5 The Climatuff compressor features internal over temperature and pressure protection and total dipped hermetic motor. Other features include: centrifugal oil pump and low vibration and noise. Condenser Coil -4TWR5 The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. Low Ambient Cooling -4TWR5 As manufactured, this unit has a cool-ing capability to 55 F. The addition of an evaporator defrost control with TXV permits low ambient cooling to 20 F. General -4TWR6 The 4TWR6 is fully charged from the factory for matched indoor section and up to 15 feet of piping. This unit is designed to operate at outdoor ambient temperatures as high as 115 Degrees Fahrenheit. Cooling capacities are matched with a wide se-lection of air handlers and furnace coils that are AHRI certified. The unit shall be certified to UL 1995. Exterior is designed for outdoor application. Casing -4TWR6 Unit casing is constructed of heavy gauge, G60 galvanized steel and painted with a weather-resistant powder paint on all louvers and panels. Cor-rosion and weatherproof CMBP-G30 DuraTuff base. Refrigerant Controls -4TWR6 Refrigeration system controls include condenser fan, compressor contactor and high pressure switch. High and low pressure controls are inherent to the compressor.A factory installed liquid line drier is standard. Compressor-4TWR6 The compressor features internal over temperature, pressure protection and total dipped hermetic motor.Other features include: Centrifugal oil pump and low vibration and noise. Condenser Coil -4TWR6 The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. Heater Section - 1 Phase Vertical Air Handler A compartment is provided in the blower section for field installation of supplementary heater. Polarized plugs are provided for making electrical connections to the air handler control box from the supplementary heater. TEM6 Painted metal cabinet with captured foil face insulation 2% or less air leakage R-4.2 Insulating Value FLD=Furnished_by Trane_U.S._loc_!Installed by Equipment Submittal -Page-5 of 42 Others Jaguar Land Rover September 19,2018 Multi-Position UP/Down Flow, Horizontal Left/Right ALL Aluminum Coil with Enhanced Patented Coil Fin Electric Heaters with polarized plug connections (sold as accessory) R-410A Thermal Expansion Valve Variable Speed ECM Motor Low Voltage Pigtail Connections Draw Through Design Horizontal Drain Pan Single Color Fused 24V Power 1 year warranty 10-year warranty registered Optional extended warranty available FLD=Furnished by Trane U.S.Inc./Installed by Others Equipment Submittal Page 6 of 42 Jaguar Land Rover September 19,2018 Unit Dimensions -Split System Air Conditioning Units (Small) Item: Al, A3 Qty: 3 Tag(s): SS-N-1, SS-N-3, SS-N-5 - a3 11/16" 2 1/8" - - ---. 21 1/8" .1111111 GAS LINE 3/4" 12 1/8"__- 8" LIQUID LINE 3/8" i .70::„ 1 im 1 155/8"189/16" 181/2" 161/2" �� 131/8" 10 ► iI!/16" 3 5/16„ 1 ii I 1 1 Al 411/16„ A A 1 9/16” - 1 7/16" - -- 7 5/16" 1" Y Y VERTICAL DOWNFLOW CONNECTIONS -0 0.88 211/16" 21/8"-=- - 1 1 1 t • ei15 1/8" 61/8 I • M 1 0 2.00 -ir 01.38 45" 0 1.50 TYP e 1 3/4" • ill 1 1 GAS LINE 3/4" 1 • 18 5/16" • 1 1�.14.' 613/16" 4 5/16" ► • 1 5/16" - o— 1 7/16" 7/8" - 18 3/4" 1 1/8" 3 11/16" -- 7/8" LIQUID LINE 3/8" —04 11/16"- 1 .111 —0 7 5/16" - -. 16 3/4" —A NOTES: ► 1.VERIFY WEIGHT,CONNECTION,AND ALL DIMENSION WTH 4 INSTALLER DOCUMENTS BEFORE INSTALLATION 7/8" AIRHANDLER DIMENSIONAL DRAWING FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal — Page 7 of 42 Others Jaguar Land Rover September 19,2018 Unit Dimensions -Split System Air Conditioning Units (Small) Item: Al Qty: 1 Tag(s): SS-N-1 'ELECTRICAL/GENERAL DATA 'GENERAL (1)(2)(4) (1) MOTOR (3) FILTERS Model: TEM6A0B30H21SA Number: 1 Type: 'Remote filter Horsepower: 0.33 Furnished: No Unit Primary Voltage: 208 Motor Speed(RPM): Variable Number: Unit Secondary Voltage: 230 Phase: 1 Recommended: Unit Hertz: 60 Full Load Amps: 2.8 Unit Phase: 1 Locked Rotor Amps: - STANDARD (5) REFRIGERANT Weights 230 Volt/208 Volt Type: R-410A Shipping: 126.0 lb REF.Line Connections 3/4" Net: 117.0 lb Minimum Circuit Ampacity: '4.0/4.0 Coupling or Conn.Size-Gas: 3/8" Maximum Overload Protection: 15.0/15.0 Coupling or Conn.Size-Lig.: ELECTRIC HEAT NOTES: 240 Volt/208 Volt 9.60/7.20 1.These air handlers are a.r.i.certified with various split system air conditioners and heat pumps Capacity Circuit#1: N/A Capacity Circuit#2: N/A (an standard 210/240).refer tothesplit system outdoor unit product data guides for performance data. Capacity Circuit#3: 2.3/4"male plastic pipe(ref.:astm 1785-76) 1 3.Minimum filter size for horizontal applications will be based on airflow selection #of Circuit: 1 and will be calculated as follows: Phase: low velocity filter:face area(sq.ft.)=cfm/300 Heater Amps Per Circuit Circuit#1: 40.0/34.6 high velocity filter:face area(sq.ft.)=cfm/500 Heater Amps Per Circuit Circuit#2: N/A 4.For customer ease of filter maintenance,it is recommended that a properly sized,remote filter and grille be Heater Amps Per Circuit Circuit#3: N/A installed for horizontal applications.airflow should not exceed the face value of the filter being used 0/47.0 5.Standard mca and mop without electric heat. 54. Minimum Circuit Ampacity Circuit#1: 54, Minimum CircuitAmpacity Circuit#2: N/A N/A Minimum CircuitAmpacity Circuit#3: Maximum Overload Protection Circuit#1: 60.0/50.0 Maximum Overload Protection Circuit#2: N/A Maximum Overload Protection Circuit#3: N/A FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 8 of 42 Others Jaguar Land Rover September 19,2018 Unit Dimensions -Split System Air Conditioning Units (Small) Item: Al Qty: 1 Tag(s): SS-N-1 NOTES 1.TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 60" ABOVE UNIT.UNIT SHOULD BE PLACED SO ROOF RUN-OFF WATER DOES NOT POUR DIRECTLY ON UNIT,AND SHOULD BE AT LEAST 12"FROM WALLAND ALL SURROUNDING SHRUBBERY ON TWO SIDES.OTHER TWO SIDES UNRESTRICTED. 2.ELECTRICAL AND REFRIGERANT COMPONENT CLEARANCES PER PREVAILING CODES. 3.VERIFY WEIGHT,CONNECTION,AND ALL DIMENSION WITH INSTALLER DOCUMENTS BEFORE INSTALLATION 37 1/4" #' ANONOPN 11 %; SERVICE PANEL SEE NOTE 27 _? 34 1/4" V'"''% i///.,hili..,. : A 1" - - 1 ELECTRICAL SERVICE PANEL-- ' 111MINII=Mr311111Mni1 111 7/8"DIA.HOLE 20" LOW VOLTAGE 291/8" 1 1/8" A.K.O.INWITHO �� 7/8"DIA HOLE IN CONTROL 1" BOX BOTTOM FOR 1111 ELECTRICAL POWER SUPPLY 140 81/8" 55/8" ltl� wiii ^ii LIQUID LINE SERVICE VALVE, I 3/8"I.D.FEMALE BRAZE 2 3/4 GAS LINE 1/4"TURN BALL CONNECTION WITH 1/4"SAE SERVICE VALVE,3/4"I.D.FEMALE FLARE PRESSURE TAP FITTING. 3 1/4" - - BRAZED CONNECTION WITH 1/4"SAE FLARE PRESSURE TAP FITTING. 4TWR50030 HEAT PUMP OUTLINE DRAWING FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal - Page 9 of 42 Others Jaguar Land Rover September 19,2018 Unit Dimensions -Split System Air Conditioning Units (Small) Item: Al Qty: 1 Tag(s): SS-N-1 ELECTRICAL/GENERAL DATA 'GENERAL POWER CONN. COMPRESSOR Model: 4TWR5030 Minimum Circuit Ampacity: '17.0 Number: '1 Unit Primary Voltage' 208 Maximum Circuit Breaker: 25.0 Phase: 1 Amps: 12.8d A Loamp Unit Secondary Voltage 230 Minimum Protection Rating: 25.0 Rated67 8 Unit Hertz: 60 Locked Rotor Amps: Unit Phase: 1 OUTDOOR MOTOR NOTES: Number: '1 1.Certified in accordance with the Unitary Air-Conditioner equipment certification program which is based on Horsepower: 0.125 AHRI Standard 210/240. Motor Speed(RPM): 825 2.Calculated in accordance with N.E.C.Use only HACR circuit breakers or fuses. Phase: 1 3.Standard line lengths-60'.Standard lift-60'Suction and Liquid line. Full Load Amps: 0.77 For Greater lengths and lifts refer to refrigerant piping software Pub#32-3312-0 Locked Rotor Amps: 4.*=15,20,25,30,40 and 50 foot lineset available. REFRIGERANT Type: 'R-410 Charge: 6.8 lb Line Size O.D.Gas: 3/4" Line Size O.D.LIQ: 3/8" Cl WEIGHT SHIPPING: 248.0 lb NET: 216.0 lb L///X 0 ,c-, , NOTES: Q Cl.TOP DISCHARGE SHOULD BE UNRESTRICTED I U FOR AT LEAST 60"ABOVE UNIT fn C2.PLACE UNIT FROM WALL 5 C4 C3.PLACE SHRUBBERY AT LEAST 12" FROM UNIT ON TWO SIDES,OTHER SIDES UNRESTRICTED C4.PLACE UNIT SO ROOF RUN-OFF DOES NOT FALL DIRECTLY ON UNIT ����������/iii,__ 4111' -----71111 C3 _ / � ------- C2 C3 WEIGHT AND CLEARANCE FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 10 of 42 Others 1 Jaguar Land Rover September 19,2018 Unit Dimensions -Split System Air Conditioning Units (Small) Item: A2 Qty: 1 Tag(s): SS-N-2 211/16" -- - 513/16" 2 1/8" – – 1^ – 12 ve"--..- 77/e" GAS LINE 7/8" rTh_____ LIQUID LINE 3/8" gem 1 .' 02.00 �II� 1 23 1/2" 21 1/2" �I� I I - 24 13/16" . 19 3/8"21 13/16" S'1.1 1 ���/16" g• 35/1 0, �� O 4 4 1 1 1 2" – o— � 1 7/16" 7" 1 9/16" 01.38 – 9 11/16"– 21/16„ – VERTICAL DOVVNFLOW CONNECTIONS 2 3/4" 21/16"–a – 00.88 _\[ O �'�`I 51/4" g u 6 15/16" I1. "1 1 0 1 1 0 2.00 01.38 gt1.50TYP F2 V8" 511/4" O I �} p • ILII I GAS LINE 7/8" 11. 24 9/16" O M(* k ]_ ■' 6 3/4" 1 I ��� O 1 1 1 1 4 5/16" 1 5/16" 7" "- o-1 7/16" 7/8" 183/4" 1 1/16" 911/16"– LIQUID LINE 3/8" o–3/8" F 7/8" s NOTES: H /4" s AIRHANDLER 1.VERIFY WEIGHT,CONNECTION,AND ALL DIMENSION WITH INSTALLER DOCUMENTS BEFORE INSTALLATION /:1 7/8" na o- DRAWING FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal — —Page 11 of 42 Others Jaguar Land Rover September 19,2018 Unit Dimensions -Split System Air Conditioning Units(Small) Item: A2 Qty: 1 Tag(s): SS-N-2 'ELECTRICAL/GENERAL DATA 'GENERAL (1) INDOOR INDOOR MOTOR (il FILTERS Model: 'TEM6A0C36H31SA Number: '1 Type: 'Remote filter Horsepower: 0.5 Furnished: No Unit Primary Voltage: 208 Motor Speed(RPM): Variable Number: Unit Secondary Voltage: 230 Phase: 1 Recommended: Unit Hertz: 60 Full Load Amps: 4.3 Unit Phase: 1 Locked Rotor Amps: - STANDARD X51 REFRIGERANT Weights 230 Volt/208 Volt Type: R-410A Shipping: 155.0 lb REF Line Connections 7/8" Net: 144.0 lb Minimum Circuit Ampacity: '5.0/5.0 Coupling or Conn.Size-Gas: 3/8" Maximum Overload Protection: 15.0/15.0 Coupling or Conn.Size-Liq.: ELECTRIC HEAT NOTES: 240 Volt/208 Volt 7.68/5.76 Capacity Circuit#1: 1.These air handlers are a.r.i.certified with various split system air conditioners and heat pumps N/A Capacity Circuit#2: N/A (an standard 210/240).refer tothesplit system outdoor unit product data guides for performance data. Capacity Circuit#3: 2.3/4"male plastic pipe(ref.:astm 1785-76) 1 3.Minimum filter size for horizontal applications will be based on airflow selection #of Circuit: 1 and will be calculated as follows: Phase: low velocity filter:face area(sq.ft.)=cfm/300 Heater Amps Per Circuit Circuit#1: 32.0/27.7 high velocity filter:face area(sq.ft.)=cfm/500 Heater Amps Per Circuit Circuit#2: N/A 4.For customer ease of filter maintenance,it is recommended that a properly sized,remote filter and grille be Heater Amps Per Circuit Circuit#3: N/A installed for horizontal applications.airflow should not exceed the face value of the filter being used 45.0/40.0 5.Standard mca and mop without electric heat. Minimum Circuit Ampacity Circuit#1: Minimum Circuit Ampacity Circuit#2: N/A N/A Minimum Circuit Ampacity Circuit#3: Maximum Overload Protection Circuit#1: 45.0/40.0 Maximum Overload Protection Circuit#2: N/A Maximum Overload Protection Circuit#3: N/A FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 12 of 42 Others Jaguar Land Rover September 19,2018 Unit Dimensions -Split System Air Conditioning Units (Small) Item: A2 Qty: 1 Tag(s): SS-N-2 NOTES 1.TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 60" ABOVE UNIT.UNIT SHOULD BE PLACED SO ROOF RUN-OFF WATER DOES NOT POUR DIRECTLY ON UNIT,AND SHOULD BE AT LEAST 12"FROM WALL AND ALL SURROUNDING SHRUBBERY ON TWO SIDES.OTHER TWO SIDES UNRESTRICTED. 2.ELECTRICAL AND REFRIGERANT COMPONENT CLEARANCES PER PREVAILING CODES. 3.VERIFY WEIGHT,CONNECTION,AND ALL DIMENSION WITH INSTALLER DOCUMENTS BEFORE INSTALLATION 1 37 1/4" t� ij SERVICE PANEL i - � SEE NOTE 2 I -__=„7-14.:i 34 1/4" I_ Nf%i/./././1.1,1111111\\\` 4 - - _ - _ , 1 ELECTRICAL SERVICE PANEL Ii��������aii 7/8"DIA.HOLE 20" LOW VOLTAGE 16 3 �Ill. � 371/8" 1 1/8"DIA.K.O.WITH 718"DIA.HOLE IN CONTROL 1" BOX BOTTOM FOR ELECTRICAL POWER SUPPLY10111 IFS[ 8 5/8" 55/8" I t ii LIQUID LINE SERVICE VALVE, 3/8"I.D.FEMALE BRAZE 3 3/8" - I- GAS LINE 1/4"TURN BALL CONNECTION WITH 1/4"SAE SERVICE VALVE,3/4"I.D.FEMALE FLARE PRESSURE TAP FITTING. 3 7/8" - - BRAZED CONNECTION WITH 1/4"SAE FLARE PRESSURE TAP FITTING. 4TWR5036 OUTLINE DRAWING FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Others ' Jaguar Land Rover September 19,2018 Unit Dimensions -Split System Air Conditioning Units (Small) Item: A2 Qty: 1 Tag(s): SS-N-2 'ELECTRICAL/GENERAL DATA 'GENERAL POWER CONN. COMPRESSOR Model: '4TWR5036 Minimum Circuit Ampacity: 18.0 Number: '1phase: 1 Unit Primary Voltage: '208 Maximum Circuit Breaker: 30.0 4.1 Unit Secondary Voltage 230 Minimum Protection Rating: 30.0 Rated Load Amps: 114 2 Unit Hertz: 60 Locked Rotor Amps: Unit Phase: 1 OUTDOOR MOTOR NOTES: Number: 1 1.Certified in accordance with the Unitary Air-Conditioner equipment certification program which is based on Horsepower: 0.125 AHRI Standard 210/240. Motor Speed(RPM): - 2.Calculated in accordance with N.E.C.Use only HACR circuit breakers or fuses. Phase: 0.64 3.Standard line lengths-60'.Standard lift-60'Suction and Liquid line. Full Load Amps: For Greater lengths and lifts refer to refrigerant piping software Pub#32-3312-0 Locked Rotor Amps: 4.*=15,20,25,30,40 and 50 foot lineset available. REFRIGERANT Type: 'R-410 Charge: 8.9 lb Line Size O.D.Gas: 7/8" Line Size O.D.LIQ: 3/8" Cl WEIGHT SHIPPING: 246.0 lb W NET: 199.0 lb Ur NOTES: Cl.TOP DISCHARGE SHOULD BE UNRESTRICTED U FOR AT LEAST 60"ABOVE UNIT Cf) C2.PLACE UNIT FROM WALL C4 C3.PLACE SHRUBBERY AT LEAST 12" FROM UNIT ON TWO SIDES,OTHER SIDES UNRESTRICTED C4.PLACE UNIT SO ROOF RUN-OFF DOES NOT FALL DIRECTLY ON UNIT 4411.111110 111 Imo C3 WEIGHT AND CLEARANCE FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 14 of 42 Others Jaguar Land Rover September 19,2018 Unit Dimensions -Split System Air Conditioning Units (Small) Item: A3 Qty: 2 Tag(s): SS-N-3, SS-N-5 ELECTRICAL/GENERAL DATA 'GENERAL (1)(2)(4) MOTOR (1) 13j FILTERS Model: 'TEM6A0B24H21SA Number: '1 Horsepower: 0.33 Type 'Remote filter Unit Primary Voltage: 208 Motor Speed(RPM): Variable Furnished: No Unit Secondary Voltage: 230 Phase: 1 Number: - Unit Hertz: 80 Full Load Amps: 2.8 Recommended: - Unit Phase: 1 Locked Rotor Amps: _ (e) STANDARD REFRIGERANT Weights 230 Volt/208 Volt Type' R-410A Shipping: 126.0 lb Minimum Circuit Ampacity: '4.0/4.0 REF.Line Connections 3/4" Net: 117.0 lb Maximum Overload Protection: 15.0/15.0 Coupling or Conn.Size-Gas: 3/8" Coupling or Conn.Size-Lig.: ELECTRIC HEAT 240 Volt/208 Volt NOTES: Capacity Circuit#1: 7.68/5.76 N/A 1.These air handlers are a.r.i.certified with various split system air conditioners and heat pumps Capacity Circuit#2. N/A (ad standard 210/240).refer tothesplit system outdoor unit product data guides for performance data. Capacity Circuit#3: 2.3/4"maleplastic pipe(ref.:astm 1785-76) #of Circuit: 1 3.Minimum filter size for horizontal applications will be based on airflow selection Phase: 1 and will be calculated as follows: low velocity filter:face area(sq.ft.)=cfm/300 Heater Amps Per Circuit Circuit#1: 32.0/27.7 high velocity filter:face area(sq.ft.)=cfm/500 Heater Amps Per Circuit Circuit#2: N/A 4.For customer ease of filter maintenance,it is recommended that a properly sized,remote filter and grille be Heater Amps Per Circuit Circuit#3: installed for horizontal applications.airflow should not exceed the face value of the filter being used Minimum Circuit Ampacity Circuit#1: 5.Standard mca and mop without electric heat. 44.0/38.0 Minimum Circuit Ampacity Circuit#2: N/A Minimum Circuit Ampacity Circuit#3: N/A Maximum Overload Protection Circuit#1: 45.0/40.0 Maximum Overload Protection Circuit#2: N/A Maximum Overload Protection Circuit#3: N/A FLD=Furnished by Trane U.S.Inc./Installed by____________ -- - - Page 75of 42 Others Jaguar Land Rover September 19,2018 Unit Dimensions -Split System Air Conditioning Units (Small) Item: A3 Qty: 2 Tag(s): SS-N-3, SS-N-5 NOTES 1.TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 60" ABOVE UNIT.UNIT SHOULD BE PLACED SO ROOF RUN-OFF WATER DOES NOT POUR DIRECTLY ON UNIT,AND SHOULD BE AT LEAST 12"FROM WALL AND ALL SURROUNDING SHRUBBERY ON TWO SIDES.OTHER TWO SIDES UNRESTRICTED. 2.ELECTRICALAND REFRIGERANT COMPONENT CLEARANCES PER PREVAILING CODES. 3.VERIFY WEIGHT,CONNECTION,AND ALL DIMENSION WITH INSTALLER DOCUMENTS BEFORE INSTALLATION 32 5/8" #0":41111 ,7-,,:- .. _� it \-- _r SERVICE PANEL .7 29 3/4" SEE NOTE 2 ` 7 �i 44‘fe' '''I'it,7 I1 1" ELECTRICAL SERVICE PANEL II 7/8"DIA.HOLE 20" LOW VOLTAGE 32 3/4" 1 1/8"DIA.K.O.WITH 7/8"DIA.HOLE IN CONTROL 1" BOX BOTTOM FOR ELECTRICAL POWER SUPPLY • 73/4" ' ,. 5,, LIQUID LINE SERVICE VALVE, 2 3/8" 3/8"I.D.FEMALE BRAZE GAS LINE 1/4"TURN BALL CONNECTION WITH 1/4"SAE SERVICE VALVE,3/4"I.D.FEMALE FLARE PRESSURE TAP FITTING. 3" BRAZED CONNECTION WITH 1/4"SAE FLARE PRESSURE TAP FITTING. 4TWR6018 and 24 OUTLINE DRAWING FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 16 of 42 Others Jaguar Land Rover September 19,2018 Unit Dimensions -Split System Air Conditioning Units (Small) Item: A3 Qty: 2 Tag(s): SS-N-3, SS-N-5 'ELECTRICAL/GENERAL DATA 'GENERAL POWER CONN. COMPRESSOR Model: 4TWR6024 Minimum Circuit Ampacity: '14.0 Number: '1 Unit Primary Voltage: '208 Maximum Circuit Breaker: 25.0 Phase: 1 Unit Secondary Voltage 230 Minimum Protection Rating: 25.0 Rated Load Amps: 10.9 Unit Hertz: 60 Locked Rotor Amps: 62.9 Unit Phase: 1 OUTDOOR MOTOR NOTES: Number: 1 1.Certified in accordance with the Unitary Air-Conditioner equipment certification program which is based on Horsepower: 0.125 AHRI Standard 210/240. Motor Speed(RPM): - 2.Calculated in accordance with N.E.C.Use only HACR circuit breakers or fuses. Phase: 0 64 3.Standard line lengths-60'.Standard lift-60'Suction and Liquid line. Full Load Amps: _ For Greater lengths and lifts refer to refrigerant piping software Pub#32-3312-0 Locked Rotor Amps: 4.'=15,20,25,30,40 and 50 foot lineset available. REFRIGERANT Type: 'R410A Charge: 7.3 lb Line Size O.D.Gas: 3/4" Line Size O.D.LIQ: 3/8" C1 WEIGHT SHIPPING: 208.0 lb NET: 174.0 lb LU C7 NOTES: Cl.TOP DISCHARGE SHOULD BE UNRESTRICTED FOR AT LEAST 60"ABOVE UNIT U C2.PLACE UNIT FROM WALL C3.PLACE SHRUBBERY AT LEAST 12" C4 FROM UNIT ON TWO SIDES,OTHER SIDES UNRESTRICTED C4.PLACE UNIT SO ROOF RUN-OFF DOES NOT FALL DIRECTLY ON UNIT //%AL-- -/ Nen N C3� �C2 C3 WEIGHTAND CLEARANCE FLD=Furnished by Trane U.S.Inc./installed by _ Equipment Submittal - Page 17 of 42 Others • Jaguar Land Rover September 19,2018 Unit Dimensions -Split System Air Conditioning Units (Small) Item: A4 Qty: 1 Tag(s): SS-P-1 - - 5 13/16" 21 1/16" 2 1/8" - 1•• - 12 1/8^1 7 7/8' GAS LINE 7/8" r---- " � � LIQUID LINE 3/8" miggilli � f�i■ E + 0 200 h� 1 III 24 13/16" 231/2" 211/Z' I ,_. dPIT67-- 193/8"2113/16"Ilona R L�1 •• 5•. " O1 1 �� 29/16 3 - 1 1 1,• i' T-F MI- 17/16" 7" 19/16" 01.38 - 911/16'- VERTICAL DOWNFLOW CONNECTIONS 21/16" - --- 21/16"-� 00.88 -r-J2 3/4 •: 51/4"1.11111 Q 615/416" • 1 0 02.00 0138 g 1.50 TYP 1 3/4" 557/8" . L 1 GAS LINE 7/8" 27 3/16" 1 111.1,;,-, IMI ■, 6 3/4" 1 ! ! I 1 1 4 5/16" 0-1 7/16" 1 5/16" 4 11/16"I 7/8" - 183/4" - - 11/16" 911/16"- LIQUID LINE 3/8'' 7/8" 1 ' �'If � o ■I NOTES: 1.VERIFY WEIGHT,CONNECTION,AND ALL DIMENSION WITH 21 3/4•• INSTALLER DOCUMENTS BEFORE INSTALLATION 1 L 718" 7/8" - AIRHANDLER DRAWING Equipment Submittal Page 18 of 42ui FLD=Furnished by Trane U.S. Inc./Installed by E q Others Jaguar Land Rover September 19,2018 Unit Dimensions -Split System Air Conditioning Units (Small) Item: A4 Qty: 1 Tag(s): SS-P-1 'ELECTRICAL/GENERAL DATA GENERAL (1)(2)(4) INDOOR MOTOR (l) FILTERS (3) Model: 'TEM6A0C60H51SA Number: '1 Type: 'Remote filter Horsepower: 0.75 Furnished: No Unit Primary Voltage: 208 Motor Speed(RPM): Variable Number: Unit Secondary Voltage: 230 Phase: 1 Recommended: - Unit Hertz: B0 Full Load Amps: 6.8 Unit Phase: 1 Locked Rotor Amps: _ (5) STANDARD REFRIGERANT Weights 230 Volt/208 Volt Type: R-410A Shipping: 185.0 lb Minimum Circuit Ampacity: '9.0/9.0 REF.Line Connections 7/8" Net: 174.0 lb Maximum Overload Protection: 15.0/15.0 Coupling or Conn.Size-Gas: 3/8" Coupling or Conn.Size-Liq.: ELECTRIC HEAT 240 Volt/208 Volt NOTES: 9.6/7.2 Capacity Circuit#1: 4.8/3.6 1.These air handlers are a.r.i.certified with various split system air conditioners and heat pumps Capacity Circuit#2. N/A (ari standard 210/240).refer tothesplit system outdoor unit product data guides for performance data. Capacity Circuit#3: 2.3/4"male plastic pipe(ref.:astm 1785-76) #of Circuit: 2 3.Minimum filter size for horizontal applications will be based on airflow selection Phase: 1 and will be calculated as follows: low velocity filter:face area(sq.ft.)=cfm/300 Heater Amps Per Circuit Circuit#1: 40.0/34.6 high velocity filter:face area(sq.ft.)=cfm/500 20.0/17.3 Heater Amps Per Circuit Circuit#2: 4.For customer ease of filter maintenance,it is recommended that a properly sized,remote filter and grille be Heater Amps Per Circuit Circuit#3: N/A installed for horizontal applications.airflow should not exceed the face value of the filter being used Minimum Circuit Ampacity Circuit#1: 59.0/52.0 5.Standard mca and mop without electric heat. Minimum Circuit Ampacity Circuit#2: 25.0/22.0 Minimum Circuit Ampacity Circuit#3: N/A Maximum Overload Protection Circuit#1: 60.0/60.0 Maximum Overload Protection Circuit#2: 25.0/25.0 Maximum Overload Protection Circuit#3: N/A __FLD=Furnished_hy_Trane-LAS.Inc.!Installed-by-_ _ -- --_- — __ ----PW a 79 of 42 Others Jaguar Land Rover September 19,2018 Unit Dimensions -Split System Air Conditioning Units (Small) Item: A4 Qty: 1 Tag(s): SS-P-1 NOTES 1.TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 60" ABOVE UNIT.UNIT SHOULD BE PLACED SO ROOF RUN-OFF WATER DOES NOT POUR DIRECTLY ON UNIT,AND SHOULD BEAT LEAST 12"FROM WALL AND ALL SURROUNDING SHRUBBERY ON TWO SIDES.OTHER TWO SIDES UNRESTRICTED. 2.ELECTRICAL AND REFRIGERANT COMPONENT CLEARANCES PER PREVAILING CODES. 3.VERIFY WEIGHT,CONNECTION,AND ALL DIMENSION WITH INSTALLER DOCUMENTS BEFORE INSTALLATION — 37 1/4" 4r 4„,. .---77,7,!!!.% \it \���\�''lilt',,,,, ,,11.4„w %; t , -jj Al SERVICE PANEL t-- -- 341/4" SEE NOTE 2 o 4 -. ; a. .0 ELECTRICAL p - NI SERVICE PANEL • I • •v -r 7/8"DIA.HOLE 20" LOW VOLTAGE 45 1/8" 1 1/8"DIA.K.O.WITH . 7/8"DIA.HOLE IN CONTROL 1 BOX BOTTOM FOR ELECTRICAL POWER SUPPLY • 8 5/8" b Ii ' I � 1 LIQUID LINE SERVICE VALVE, 3/8"I .FEMALE BRAZE 3 3/8 --- \—GAS LINE 1/4"TURN BALL CONNECTION WITH 1/4"SAE SERVICE VALVE,1 1/8"I.D.FEMALE FLARE PRESSURE TAP FITTING. 3 7/8" BRAZED CONNECTION WITH 1/4"SAE FLARE PRESSURE TAP FITTING. 4TWR5060 OUTLINE DRAWING FLD=Furnished by Trane U.S. Inc./Installed by Equipment Submittal Page 20 of 42 Others Jaguar Land Rover September 19,2018 Unit Dimensions -Split System Air Conditioning Units (Small) Item: A4 Qty: 1 Tag(s): SS-P-1 'ELECTRICAL/GENERAL DATA GENERAL POWER CONN. COMPRESSOR Model: '4TWR5060 Minimum Circuit Ampacity: '32.5 Number: '1 Unit Primary Voltage: '208 Maximum Circuit Breaker: 50.0 Phase: 1 Unit Secondary Voltage 230 Minimum Protection Rating: 50.0 Rated Load Amps: 23.7 Unit Hertz: 60 Locked Rotor Amps: 152.5 Unit Phase: 1 OUTDOOR MOTOR NOTES: Number: '1 1.Certified in accordance with the Unitary Air-Conditioner equipment certification program which is based on Horsepower: 0.33 AHRI Standard 210/240. Motor Speed(RPM): 850 2.Calculated in accordance with N.E.C.Use only HACR circuit breakers or fuses. Phase: 1 3.Standard line lengths-60'.Standard lift-60'Suction and Liquid line. Full Load Amps: 2.80 For Greater lengths and lifts refer to refrigerant piping software Pub#32-3312-0 Locked Rotor Amps: 4.*=15,20,25,30,40 and 50 foot lineset available. REFRIGERANT Type: 'R-410 Charge: 10.6 lb Line Size O.D.Gas: 1 1/8" Line Size 0.D.LIQ: 3/8" Cl WEIGHT SHIPPING: 301.0 lb NET: 251.0 lb LI-I C7 NOTES: Cl.TOP DISCHARGE SHOULD BE UNRESTRICTED FOR AT LEAST 60"ABOVE UNIT CJ C2.PLACE UNIT FROM WALL 0 C3.PLACE SHRUBBERY AT LEAST 12" C4 FROM UNIT ON TWO SIDES,OTHER SIDES UNRESTRICTED C4.PLACE UNIT SO ROOF RUN-OFF DOES NOT FALL DIRECTLY ON UNIT da— N • �C2 C3 WEIGHT AND CLEARANCE FLD=Furnished by Trance - -- - - Page 21 of 42 Others Jaguar Land Rover September 19,2018 Weight, Clearance& Rigging Diagram -Split System Air Conditioning Units (Small) Item: Al -A4 Qty: 5 Tag(s): SS-N-1, SS-N-2, SS-N-3, SS-N-5, SS-P-1 0fj. ED0 0 0 0 C ( -),-7-------------- ----------REFRIGERANT CONNECTION v DOWNFLOW CONDENSATE 0 . —REFRIGERANT CONNECTION DRAIN . O (( 11 f\I UPFLOW CONDENSATE DRAIN I I VERTICAL UPFLOW VERTICAL DOWNFLOW REFRIGERANT CONNECTION \ s a 00 . gi __= r =00 10=>0®° 0 • HORIZONTAL CONDENSATE DRAIN J HORIZONTAL CONDENSATE DRAIN HORIZONTAL RIGHT FLOW HORIZONTAL LEFT FLOW MINIMUM UNIT CLEARANCE TABLE TO COMBUSTIBLE SERVICE CLEARANCE MATERIALS(REQUIRED) (RECOMMENDED) SIDE 0 2" FRONT 0 21" BACK 0 0 NOTES 1.NO INTERNAL MODIFICATIONS REQUIRED FOR ANY POSITION. INLET DUCT 0 1" 0 2.BADGE ROTATION WILL BRAND IN CORRECT POSITION. OUTLET DUCT 1" CLEARANCE NOTES: 1"FOR THE FIRST 36".OF OUTLET DUCT WHEN ELECTRIC HEATERS ARE INSTALED 0"AFTER THE FIRST«36.00—LN» FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 22 of 42 Others Jaguar Land Rover September 19,2018 Accessory -Split System Air Conditioning Units (Small) Item: Al -A4 Qty: 5 Tag(s): SS-N-1, SS-N-2, SS-N-3, SS-N-5, SS-P-1 6" - 1 3/8" C. 711 ((II' 4 5/8 __I_ - 3 5/16" I. 1 I 3 5/16" ( O !ID m Mt UP Iji EIJ r -LTJ, Q TCONT200 ACCESSORY-THERMOSTAT FLD=Furnished 1 Trane LL,1 Inc I Installed by rage 23 of 42 Others Jaguar Land Rover September 19,2018 Tag Data -Split System Air Conditioning Units (Large) (Qty: 1) Item Tag(s) Qty Description Model Number B1 FCU-N-4 1 7.5 Ton Unitary Split Systems TWE09043AAA Indoor Product Data -Split System Air Conditioning Units (Large) Item: B1 Qty: 1 Tag(s): FCU-N-4 Air Handler 7.5 Ton R-410A 208-230/60/3 (field convertible to 460/60/3) Single Circuit Standard Motor Electric Heat—25kW Economizer(Mixing box) (Fid) Performance Data -Split System Air Conditioning Units (Large) Tags FCU-N-4 Field Applied Voltage 460/3/60 Airflow(cfm) 3000 External Static Pressure (in H2O) 0.500 Cooling EDB (F) 80.00 Cooling EWB (F) 67.00 Ambient Temperature (F) 95.00 Heating EDB (F) 70.00 Heating Ambient DB (F) 17.00 Heating Ambient WB (F) 15.00 Gross total capacity (MBh) 90.08 Gross sensible capacity (MBh) 74.13 Latent capacity(MBh) 15.94 Net total capacity (MBh) 86.11 Net sensible capacity (MBh) 70.17 Cooling LDB (F) 58.52 Cooling LWB (F) 57.87 External plus component static pressure (in H2O) 0.500 Indoor mtr operating power(bhp) 1.26 Indoor motor RPM (rpm) 807 MCA- Indoor. (A) 41.00 MOP— Indoor(A) 45.00 Evaporator motor FLA (A) 5.30 Evaporator face area (sq ft) 8.07 Evaporator face velocity (ft/min) 386 Evaporator fin spacing (Per Foot) — 168 Evaporator Rows () 4 Indoor motor power(kW) 1.15 EER @ AHRI (with air handler) (EER) 11.0 Min A.H. operating weight (Ib) 323.0 Max A.H. operating weight(Ib) 360.0 Fan motor heat (MBh) 3.05 FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 24 of 42 Others Jaguar Land Rover September 19,2018 Mechanical Specifications -Split System Air Conditioning Units (Large) Item: B1 Qty: 1 Tag(s): FCU-N-4 General -TWE Completely Factory Assembled Convertible for Horizontal or Vertical Configuration Convertible for Cooling Only or Heat Pump Application Convertible for Left or Right External Connections(Refrigerant and/or Electrical)Convertible for Front or Bottom Air Return Nitrogen Holding Charge Certified and Rated in Accordance with AHRI and DOE Standards Certified to UL 1995 for Indoor Blower Coil Units Casing -TWE Zinc Coated, Heavy Gauge, Galvanized Steel Weather Resistant Baked Enamel Finish Access Panels with Captive Screws Completely Insulated with Foil Faced, Cleanable, Fire Retardant, Permanent, Odorless Glass Fiber Material Captured or Sealed Insulation Edges Electrical Connection Bushings or Plugs Refrigerant Connection Bushings or Plugs Withstand Elevated Internal Static Pressure Refrigeration System -TWE Single or Dual Circuit Distributor(s) Thermal Expansion Valves (TXVs) Evaporator Coil -TWE 3/8" Internally Enhanced Copper Tube Mechanically Bonded to Lanced Aluminum Plate Fins Factory Pressure and Leak Tested to 449 psig. Draw-Through Airflow Dual Circuits Are Interlaced/Intertwined Double Sloped, Removable, Cleanable, Composite Drain Pan Four Drain Pan Positions Indoor Fan -TWE Double Inlet, Double Width, Forward Curved, Centrifugal Type Fan Dual Fans On 10.4-20.912.5-25 Ton Air Handlers Adjustable Belt Drive Permanently Lubricated Bearings Indoor Motor-TWE Adjustable Motor Sheaves Fixed Motors Sheaves (SZVAV and 2-Speed VFD) Thermal Overload Protection Permanently Lubricated Bearings Meet Energy Policy of 1992 (EPACT) Optional Over Sized Motors for High Static Applications Controls -TWE Completely Internally Wired Numbered and Colored Wires Magnetic Indoor Fan Contactor Low Voltage Terminal Strip Single Point Power Entry Evaporator Defrost Control Filters -TWE Access From Side Coil Panels Filters Slide on Rack One Inch (1"), Throw-Away Filters on 4.6-8.335-10 Ton Units Filter Rack Convertible to Two Inch (2") Capability on 5-10 Ton Units Two Inch (2"), Throw-Away Filters on 10.4-20.912.5-25 Ton Units FLD=Fumished by-Trate-U..&Inc.Installed-by Page 25 of 42 Others Jaguar Land Rover September 19,2018 Unit Dimensions -Split System Air Conditioning Units (Large) Item: B1 Qty: 1 Tag(s): FCU-N-4 NOTES: 1 PANEL DEPTH 1/2"(TYP.ALL PANELS). 25 1/2" 2.REMOVABLE DRAIN PAN AND ATTACHED DRAIN CONNECTION MAY BE INSTALLED ON END OF UNIT IN EITHER THE VERTICAL OR HORIZONTAL CONFIGURATION,PLASTIC DRAIN PAN SUPPLY 70„ ACCESS PLATE ON THE END OF UNIT OPPOSITE DRAIN CONNECTION MUST BE REMOVED TO OPEN SLIDE DRAIN PAN OUT OF UNIT CLEANING.ACCESS PLATE MUST BE RE-INSTALLED AFTER - 161/4" - SLIDING DRAIN PAN BACK INTO UNIT. 3.IF PERIODIC DRAIN PAN CLEANING IS REQUIRED,ALLOW ROOM FOR PARTIAL REMOVAL OF DRAIN PAN40 CONNECTION ATP END OF RAN IT. CONNECTION 4.1"FEMALE SCHED.40 PVC PIPE DRAIN COVERTICAL CONFIGURATION. 11/16" 5.1"FEMALE SCHED.40 PVC PIPE DRAIN CONNECTION HORIZONTAL CONFIGURATION. 1.1- 11 47 1/2" 241/16" I - - hAu'III'I 161/16" SIIDERETU RN 16 7/8" BOTTOM RETURN — q DUCT FLANGE 1 9/16" 1 13/16" 1"HEIGHT 2 3/4"-- - 42" - 2 3/4" - 42" - 251/2" - CONTROL WIRING 11161.. 31/2" LINE VOLTAGE ��_ — 01 COLDER LIQUIDLINE 1=1=11) 8 13/16" FIELD CONNECTION I CONTROL BOX , I 16" ACCESS PANEL 1 3/16" -I - 1 COPPER SUCTION LINE DRAIN CONNECTION REMOTE BULB TXV FIELD CONNECTION FOR HORIZONTAL ,, (SEE NOTE 2,3,5) N- SUCTION LINE 22 7/8" 17 7/16" 20" 17 3/8" 16 11/16" 16111/16" I 1 i , foil 0 0 0 0 0 I 1.01 FILTER ACCESS PANEL 3 5/8" 1 9/16" ' SEE NOTES 2,3,4 22"MIN.DISTANCE BOTH SIDE - 1 11/16" 3 1/2" - LIQUID LINES SEE NOTES 2,3,4 1 3/16 - 45 1/8" - (4)-HOLE FOR HORIZONTAL SUSPENSION (4) HOLE FOR SUPPLY OPENING HORIZONTAL 6 3/4" i SUSPENSION • 01.11111 BOTTOM RETURN -.°41111411 . \.... 36 7/8" SIDE RETURN �! : . 54 1/16" FILTER ' RETURN'..---...'-'-'-'-''.11144444 . • . I 1 1 ,. SIDE RETURN 10 7/16" = • . BOTTOMU R 14 . 111111 SUPPLY VERTICAL- SUPPLY HORIZONTAL- RETURN HORIZONTAL/ RETURN VERTICAL/ RETURN VERTICAL RETURN HORIZONTAL 7 1/2 TON AIR HANDLER (SINGLE CIRCUIT) DIMENSIONAL DRAWING FLD=Furnished by Trane U.S. Inc./Installed by Equipment Submittal Page 26 of 42 Others Jaguar Land Rover September 19, 2018 Unit Dimensions -Split System Air Conditioning Units (Large) Item: B1 Qty: 1 Tag(s): FCU-N-4 AIR HANDLER ELECTRICAL DATA 'ELECTRICAL DATA 'Convertible 460 Voltages EVAPORATOR FAN MOTOR (9) Convertible 460 Voltages Model: 'TWE090 'TWE090 Vol: Unit Operating Voltage: 187-253 414-506 V 2 1 Minimum CircuitAmpacity: 7.0 3.0 Ph208-230 460 Phase: Phase: 3 3 Maximun Fuse Size: 15.0 15.0 Motor HP: 1.50 1.50 Maximun Circuit Breaker: 15.0 Amp-FLA: 5.3-5.0 2.5 Amp-LRA: 34.3-34.3 17.0 GENERAL DATA SYSTEM DATA INDOOR COIL-TYPE No.Refrigerant Circuits '1 Tube Size: '3/8" Suction Line(in.)OD 1 3/8" Face Area: 8 1/8" Liquid Line(in.)OD 1/2" Row/FPI 4/14 Refrigerant Control EXPANSION VALVE Drain Connection Size 1"PVC INDOOR FAN FILTER Type: 'CENTRIFUGAL Type: 'THROWAWAY No.Used/Diameter x Width: 1/15"X15" Furnished: YES Drive Type/No.Speed: BELT/ADJUSTABLE No.Size Recommended: (3)16"X25"X1" CFM: 3000 No.Motor: 1 Motor HP-Standard/Oversized: 1.5/2.0/3.0 Motor RPM: 1725 Motor Frame Size: 56H HEATER DATA ELECTRICAL DATA Notes: Heat Rating(kW): 1. KW ratings are at:208/240V for 208-230V air handlers Control Stages: 480V for 460V air handlers Power Supply: 600V for 575V air handlers Minimum Circuit Ampacity: _Voltage_ For other than rated voltage,capacity=( setae Voneoe )x 2 Rated Capacity Maximun Fuse Size: 2.Any power supply and circuits must be wired and protected in accordance Maximun Circuit Breaker: with local electrical codes. 3. The HACR circuit breaker is for U.S.A.installations only. '4. With motor field converted to 460V. NOTES: 1.Cooling performance is rated at 95 F ambient,80 F entering dry bulb,67 F entering wet bulb. 2.Gross capacity does not include the effect of fan motor heat.AHRI capacity is net and includes the effect of fan motor heat. Ratings shown are tested and certified in accordance with AHRI Standard 340/360 or 365 certification program. 3.Condensing Unit Only Gross Cooling Capacity rate at 45 F saturated suction temperature and at 95 F ambient. 4.AHRI Net Cooling Capacity is calculated with matched blower coil and 25 ft.of OD interconnecting tubing. EER is rated at AHRI conditions and in accordance with DOE test procedures. L. - . -- 5.Integrated Part Load Value is based on AHRI Standard 340/360 or 365. Units are rated at 80 F ambient, 80 F entering dry bulb,and 67 F entering wet bulb at AHRI rated CFM. 6.Sound Rating shown is tested in accordance with AHRI Standard 270. 7.Refer to refrigerant piping program for line sizing and line length. 8.Refrigerant(operating)charge is for condensing unit(all circuits)with matching blower coils and 25 ft. of interconnecting refrigerant lines.All units are shipped with a small nitrogen holding charge only. 9.Second Column data Coverable to 460 volt FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page z or az Others Jaguar Land Rover September 19,2018 Weight, Clearance& Rigging Diagram -Split System Air Conditioning Units (Large) Item: B1 Qty: 1 Tag(s): FCU-N-4 #4 #1 WEIGHTS AND CORNER WEIGHTS B C J• o ^ o • • Shipping: 360.0 lb .. .. Net 323.0 lb VERTICAL Corner 1: 67.0 lb • 1 Corner 2: 99.0 lb Corner 3: 75.0 lb Corner 4: 82.0 lb . . HORIZOTNAL ' Corner A: 56.0 lb '' "" Corner B: 92.0 lb Corner C: 87.0 Ib o.. Corner D: 88.0 Ib —.— —. O O #3 #2 A D AIR FLOW HORIZONTAL I ll I I I ' HORIZONTAL ... 0. RETURN IESk> `‘\ I L AIR FLOW \\ \ \ •\ J i RETURN VERTICAL VERTICAL RETURN RETURN WEIGHTS AND LOAD POINT LOCATION FOR CONDENSOR WEIGHT AND RIGGING FLD=Furnished by Trane U.S. Inc./Installed by Equipment Submittal Page 28 of 42 Others Jaguar Land Rover September 19,2018 Field Wiring -Split System Air Conditioning Units (Large) Item: B1 Qty: 1 Tag(s): FCU-N-4 TO POWER SUPPLY PER LOCAL CODES o � o n n n L I3 PHASE 1 ONLY I I I 1 I I 1 o —0 o SUPPLY HEATER ——— CONTROL BOX SEE NOTE 9 1 LL--®� SEE NOTE 5&6 STAGEIHEAT ——1—— ® W1 STAGE 2 HEAT ---L---- FAN — ® G` COMPRESSOR — ® 24 VAC ® R SEE NOTE 8 24 VAC COMMON ®—B1 TO OUTDOOR UNIT — ®—B2 HEATANTICIPATOR ® T COOLING REVERSING VALVE — ® 0 EDC nnn AIR HANDLER 3 PHASE ONLY TO POWER SUPPLY PER LOCAL CODES INTER-COMPONENT WRING 24 VOLT ILINE VOLT FACTORY WRING ———— 24 VOLT FIELD WRING EUNE VOLT NOTES: 1.POWER WRING AND GROUNDING OF EQUIPMENT MUST COMPLY WITH LOCAL CODES. 2.BE SURE POWER SUPPLY AGREES WITH EQUIPMENT NAMEPLATE. 3.LOW VOLTAGE WIRING TO BE 18A.W.G.MINIMUM CONDUCTOR. 4.USE COPPER CONDUCTORS ONLY. 5.IF TWO STAGE ELECTRIC HEATERS AND THERMOSTATARE USED,REMOVE JUMPER BETWEEN WI AND W2. 6.FOR SINGLE STAGE ELECTRIC HEATER,OMIT WIRE BETWEEN W2 AND THERMOSTAT AND W2 AND ELECTRIC HEATER. 7.FOR COOLING ONLY,OMIT WIRES BETWEEN WI,W2AND THERMOSTAT AND OMIT ELECTRIC HEATER. 8.IF THE EDC SWITCH IS TO BE CONNECTED IN THE CIRCUIT,THE EDC WIRE MUST BE REMOVED FROM THE B1 TERMINALAND RECONNECTED TO THE"Y"TERMINAL ON THE INDOOR SECTION LOW VOLTAGE TERMINAL BOARD AS SHOWN. 9.WHEN ELECTRIC HEATER ACCESSORY IS USED,SINGLE POINT POWER ENTRY OR DUAL POINT POWER ENTRY IS FIELD OPTIONAL.SINGLE POINT POWER ENTRY OPTION IS THROUGH ELECTRIC HEATER ONLY. FLD=Furnished by Trane U.S.Inc.I Installed by _ _ _Fry uipment Submittal Page 2&of 42 Others Jaguar Land Rover September 19,2018 Tag Data -Split System Air Conditioning Units (Large) (Qty: 1) Item Tag(s) Qty Description Model Number Cl CU-N-4 1 7.5 Ton Unitary Split Systems TWA09044AAA Outdoor Product Data -Split System Air Conditioning Units (Large) Item: Cl Qty: 1 Tag(s): CU-N-4 Heat Pump Outdoor Unit (TWA) 7.5 Tons R-410A Refrigerant 460/60/3 Single Compressor ReliaTel (Heat Pump) 3H/2C Digital 7 day Prog Touchscreen (Fld) FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 30 of 42 Others Jaguar Land Rover September 19,2018 Mechanical Specifications -Split System Air Conditioning Units (Large) Item: C1 Qty: 1 Tag(s): CU-N-4 General -TWA Weatherproofed Steel Mounting/Lifting Rails Hermetic Scroll Compressors Plate Fin Condenser Coils Fans and Motors Standard Operating Range 50-125F (Min. 0°F with Low Ambient Accy) Nitrogen Holding Charge Certified and Rated in Accordance with AHRI and DOE Standards Certified to UL 1995 Casing -TWA Zinc Coated, Heavy Gauge, Galvanized Steel Weather Resistant Baked Enamel Finish Meets 672 hr Salt Spray Test Removable Single Side Maintenance Access Panels Lifting Handles in Maintenance Access Panels Unit Base Provisions for Forklift and/or Crane Lifting Refrigeration System - TWA Single Compressor(TWA073D, TWA090D, TWA120D) Single Refrigeration Circuit with Integral Subcooling Circuit. Single Direct Drive Hermetic Scroll Compressor with Centrifugal Oil Pump Providing Lubrication To Moving Parts Suction Gas-Cooled Motor w/± 10%Voltage Utilization Range of Unit Nameplate Voltage Reversing Valve Crankcase Heater Internal Temperature and Current Sensitive Motor Overloads No Compressor Suction and/or Discharge Valves (Reduced Vibration/Sound) Factory Installed Liquid Line Filter Drier Phase Loss/Reverse Rotation Monitor Liquid Line Service Valve (with gauge port) Suction Line Service Valve (with gauge port) External High Pressure Cutout Device External Low Pressure Cutout Device Evaporator Defrost Control Loss of Charge Protection (Discharge Line Thermostat) Condenser Coil -TWA 3/8" Internally Enhanced Copper Tube Mechanically Bonded to Lanced Aluminum Plate Fins Factory Pressure and Leak Tested to 660 psig. Condenser Fan -TWA 26"or 28" Propeller Fan(s) Direct Drive Statically and Dynamically Balanced Condenser Motor(s) -TWA Permanently Lubricated Totally Enclosed or Open Construction Built-In Current and Thermal Overloads Ball or Sleeve Bearing Type Controls -TWA Centralized MicroProcessor Indoor and Outdoor Temperature Sensors Drive Algorithms Making Decisions for All Heating, Cooling, and Ventilation Integrated Anti-Short Cycle Timer Integrated Time Delay Between Compressors Completely Internally Wired Numbered and Colored Wires Contactor Pressure Lugs or Terminal Block Unit External Mounting Location for Disconnect Device Single Point Power Entry FLD=Furnishedhy_Trane U S lnc_lInstalled by Page 31 oi42 Others Jaguar Land Rover September 19,2018 Unit Dimensions -Split System Air Conditioning Units (Large) Item: Cl Qty: 1 Tag(s): CU-N-4 SEE NOTE 3 NOTES: 1.ACCESS OPENING IS FOR FIELD INSTALLED BAYLOAM ACCESSORY. 2.MINIMUM CLEARANCE FOR PROPER OPERATION IS 36"FROM /((f,' ui s,.'�.99)))))) )` WALLS,SHRUBBERY,PRIVACY FENCES ETC.MINIMUM CLEARANCE ‘,.&„\�i� j , � BETWEEN ADJACENT UNITS IS 72".RECOMMENDED SERVICE SERVICE PANEL /�,✓ CLEARANCE 48" \ 3.TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR 100" MINIMUM.UNIT SHOULD BE PLACED SO ROOF RUN-OFF WATER DOES ® liii i NOT POUR DIRECTLY ON UNIT 4.OUTDOOR AIR TEMPERATURE SENSOR OPENING(DO NOT BLOCK OPENING) �' HAIL GUARD ' (OPTIONAL) SEE NOTE 4 kiiiii SERVICE CLEARANCE 48"(SEE NOTE 2 FOR CLEARANCE) 1 3/16" 36" HAIL GUARD WITH HAIL GUARD SEE NOTE 1 (OPTIONAL) 41/4" - - LINEVOLTAGE 3315/16"-- 1 REFRII i Frrrn rrr,GERANT ACESS CONTROL WRING r jllili l !lilii ! f!Ii II I ! III iII II III I ! IIIi !jllill i ! ! ! III i jji j i l li ! ! Ili I ` j" i i I i i iiia �i `l ii III iii I SERVICE PANEL393/16" i I . . I 363/8" Ir iiIjIjjjl !Ilii6" Ijij lIII ijll 2913/1 ..III . , ; 26 15/16" jjii !liiII! !i , i 143/8" !Iljliiji !jifij 1111 iililjjijijllilO ii ii II Ii�r--- =_— 5 5/8" 8 5/16" i I Er-ate 1E1 -7] 31/16" - 6" LIQUID LINE A 33/4" 2 - 21 11/16" - SUCTION LINE _ - 37/16" - 41 1/8" - - 33 13/16" - - 42 1/8" WITH HAIL GUARD SERVICE PANEL SIDE 3" 4 7/16"DIA.ISOLATOR MOUNTING HOLES(OUTSIDE HOLES=4 PLACES) BOTTOM 40 3/4" 34 3/4" OF UNIT I 4 3/16" - 1 13/16" - 27 11/16" - - 25/16" 6-7 1/2 TON HEAT PUMP CONDENSER (SINGLE COMPRESSOR) DIMENSIONAL DRAWNG FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 32 of 42 Others Jaguar Land Rover September 19,2018 Unit Dimensions -Split System Air Conditioning Units (Large) Item: Cl Qty: 1 Tag(s): CU-N-4 'ELECTRICAL DATA CONDENSER 'ELECTRICAL DATA COMPRESSOR MOTOR CONDENSER FAN MOTOR Model: 'TWA09044A No.: '1 No.: '1 Unit Operating Voltage: 414-506 Volts: 460 Volts: 460 Minimum Circuit Ampacity: 18.0 Phase: 3 Phase: 1 Maximum Fuse Size: 30.0 Amp-RLA: 12.8 Amp-FLA: 1.6 Maximum Circuit Breaker 30.0 Amp-LRA: 100.0 Amp-LRA: 3.8 GENERAL DATA CONDENSER COOLING PERFORMANCE ()(2)(3114)(5) COMPRESSOR Matched Air Handler: 'TWE0904*A* Number: Condensing Unit Only: 84,000 'Scroll ARI Net Cooling Capacity: No.Compressor/Tons: 1/6.9 86,000 Matched Air Handler (EER): 113 Condensing Unit Only (EER): System KW 11.0 Condensing Unit KW: 7.6 SYSTEM DATA (7) 6.8 No.Refrigerant Circuits: '1 System IEER: Suction Line(in.)OD: 1 3/8" Liquid Line(in.)OD: 1/2" '12.4 OUTDOOR COIL OUTDOOR FAN Tube Size(in.)OD '3/8" No.Used/Diameter(in.): '1/26" Face Area(sq.ft.) 19 1/4" Drive Type/No.Speeds: DIRECT/1 Rows/FPI 2/18 No.Motors/HP: 1/0.5 Motor RPM: 1,100 REFRIGERANT CHARGE(Fld Supplied) (7)(E) TYPE: 'R-410A (Circuits#1): 22.0 lb (Circuits#2): N/A NOTES: 1.Cooling performance is rated at 95 F ambient,80 F entering dry bulb,67 F entering wet bulb. Gross capacity does not include the effect of fan motor heat.AHRI capacity is net and includes the effect of fan motor heat. Ratings shown are tested and certified in accordance with AHRI 2. Standard 340/360 or 365 certification program. 3.Condensing Unit Only Gross Cooling Capacity rate at 45 F saturated suction temperature and at 95 F ambient. 4.ARI Net Cooling Capacity is calculated with matched blower coil and 25 ft.of OD interconnecting tubing. EER is rated at AHRI conditions and in accordance with DOE test procedures. 5.Integrated Part Load Value is based on AHRI Standard 340/360 or 365. Units are rated at 80 F ambient, 80 F entering dry bulb,and 67 F entering wet bulb at AHRI rated CFM. 6.Sound Rating shown is tested in accordance with AHRI Standard 270. 7.Refer to refrigerant piping program for line sizing and line length. 8.Refrigerant(operating)charge is for condensing unit(all circuits)with matching blower coils and 25 ft. of interconnecting refrigerant lines.All units are shipped with a small nitrogen holding charge only. FLD=Furnished by Trane U.S,Inc(Installed by _ Others ++P +�Subrr�ittaE Page-3342 Jaguar Land Rover September 19,2018 Weight, Clearance&Rigging Diagram -Split System Air Conditioning Units (Large) Item: Cl Qty: 1 Tag(s): CU-N-4 0 (r"'/,�� 'nt�.Ko ,n))))))))) l, )� o !I iis. SERVICE PANEL ' 4 0 0 011willfr I 0 ----I-1 1/4"DIA.LIFTING HOLES(4 PLACES) #2 #3 SERVICE PANEL—, A •;� WEIGHTS AND CORNER WEIGHTS O � �� Shipping: 383.0 Ib / �\ Net 333.0 Ib • /�%i',,--, � Corner 1: 83.0 lb �/"� �°'" ` Corner 2: 117.0 Ib ff01001,00-14 orner 3: 60.0 Ib 1t � C 73.0 lb � II, Corner 4: "-• ir- v #1 #4 WEIGHTS AND LOAD POINT LOCATION WEIGHT AND RIGGING FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 34 of 42 Others Jaguar Land Rover September 19,2018 Accessory -Split System Air Conditioning Units (Large) Item: Cl Qty: 1 Tag(s): CU-N-4 6" 1 3/8" (ii'45/8" - _I,i 'li - 3 5/16" - O O I iIO ML41;D 35/16" - O71LSI' I t \ TCONT800/802/803 ACCESSORY-THERMOSTAT FLD=Furnished by Trane US.Inc.!Installed by - Page 35 of 42 Others Jaguar Land Rover September 19,2018 Field Wiring -Split System Air Conditioning Units (Large) Item: Cl Qty: 1 Tag(s): CU-N-4 ROOM THERMOSTAT FIELD RH RC Y1 G W1 W2 Y2 SUPPLIED JUMPER El L ® 1st STAGE HEAT L---- © 2nd STAGE HEAT L El FAN Y1- El L24 VAC OUTDOOR SECTION R- u 24 VAC COMMON B1- B2- C3 Iri-D1--, EDC II II II ii TYPICALAIR HANDLER ii ii ii ii II II II II LOW VOLTAGE TERMINAL BOARD II 11 II II-71 TO POWER SUPPLY PER LOCAL CODES INTER-COMPONENT WRING 24 VOLT FACTORY WRING I LINE VOLT ———— 124 VOLT FIELD WIRING =——= {LINE VOLT NOTES: 1.POWER WIRING AND GROUNDING OF EQUIPMENT MUST COMPLY WITH LOCAL CODES. 2.BE SURE POWER SUPPLY AGREES WITH EQUIPMENT NAMEPLATE. 3.LOW VOLTAGE WIRING TO BE 18A.WG.MINIMUM CONDUCTOR. 4.USE COPPER CONDUCTORS ONLY. FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 36 of 42 Others • Jaguar Land Rover September 19,2018 Field Wiring -Split System Air Conditioning Units (Large) Item: Cl Qty: 1 Tag(s): CU-N-4 RTRM TWA LTB1 R I Y1 I WI/OIG W2I Y2 I X2 I T COM I BHI T2 I EF I H1 I H2 I CD' R II I I II I I I I I I r r J r--J I r--J II I I E— li I I I I IB2I BII G IWII W2I CDI R Y1 I Y2 J R I Y IO/B I G I W1IY2ICOMI I I LJ THERMOSTAT TWE -- LTB2 EDC NOTES: 1.POWER WIRING AND GROUNDING OF EQUIPMENT MUST COMPLY WITH LOCAL CODES. 2.BE SURE POWER SUPPLY AGREES WITH EQUIPMENT NAMEPLATE. 3.LOW VOW VOLTAGE WIRING TO BE 18 A.W.G.MINIMUM CONDUCTOR. 4.USE COPPER CONDUCTORS ONLY. 5.REMOVE JUMPER BETWEEN W1 AND W2 IF ODT ACCESSORY IS USED. FLD=Furnished by Trane U.S. Inc./Installed by Equipment Submittal Page 37 of 42 Others Jaguar Land Rover September 19,2018 Field Installed Options -Part/Order Number Summary This is a report to help you locate field installed options that arrive at the jobsite. This report provides part or order numbers for each field installed option, and references it to a specific product tag. It is NOT intended as a bill of material for the job. Product Family -Split System Air Conditioning Units (Small) Item Tag(s) Qty Description Model Number Al SS-N-1 1 2.5 Ton Unitary Split Systems (SSC) T R5O3OH1- S Field Installed Option Description Part/Ordering Number 7.21/9.60 kW Electric Htrw/Ckt Brk for 208/240V 1 Phase 60 Hz BAYHTR1510BRKC Programmable 7 day , 3 heat/2 cool thermostat TCONT802AS32DA Item Tag(s) Qty Description Model Number A2 SS-N-2 1 3 Ton Unitary Split Systems (SSC) 4TWR5036H1- Field Installed Option Description Part/Ordering Number 5.77/7.68 kW Electric Heater for 208/240V 1 Phase 60 Hertz BAYHTR1508LUGB Programmable 7 day , 3 heat/2 cool thermostat TCONT802AS32DA Item Tag(s) Qty Description Model Number A3 SS-N-3, SS-N-5 2 2 Ton Unitary Split Systems (SSC) 4TWR624H1- TEM6A0B24H21S Field Installed Option Description Part/Ordering Number Programmable 7 day , 3 heat/2 cool thermostat TCONT802AS32DA 5.77/7.68 kW Electric Htr w/Ckt Brk for 208/240V 1 Phase 60 Hz BAYHTR1508BRKC Item Tag(s) Qty Description Model Number A4 SS-P-1 1 5 Ton Unitary Split Systems (SSC) 4TWR5O6OH1- Field Installed Option Description Part/Ordering Number Programmable 7 day , 3 heat/2 cool thermostat TCONT802AS32DA 10.80/14.40 kW Electric Heater for 208/240V 1 Phase 60 Hertz BAYHTR1516BRKA Product Family -Split System Air Conditioning Units Outdoor(Large) Item Tag(s) Qty Description Model Number Cl CU-N-4 1 7.5 Ton Unitary Split Systems Outdoor TWA09044AAA 'Field Installed Option Description Part/Ordering Number 3H/2C Digital 7 day Prog Touchscreen ITCONT802AS32DA FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 38 of 42 Others ���CanFab TEM 6 1 8, 2 4 , 3 0 CANNON FABRICATION INC 182 GRANITE STREET, SUITE 101, CORONA, CA 92879 PHONE:(951)278-1830 FAX:(951)278-8444 www.canfab.com canfabOcanfab.com PART NO: SEE BELOW STYLE A & Al SS-N-1, FEATURES SS-N-3, 1 - FULLY MODULATING HONEYWELL CONTROL SYSTEM AVAILABLE WITH SS-N-5 DRYBULB, SINGLE ENTHALPY OR COMPARATIVE (DIFFERENTIAL) ENTHALPY SENSOR(S) AND HONEYWELL OR BELIMO ACTUATOR. SEE MODEL NUMBER BREAK DOWN BELOW. 2 - HEAVY GAUGE STEEL CONSTRUCTION WITH GALVANIZED FINISH. 3 - RETURN AIR AND OUTSIDE AIR DAMPERS ARE THE SAME SIZE. RETURN AIR SHOWN OPEN, OUTSIDE AIR SHOWN CLOSED AND ACCESS PANEL AS SHOWN. SEE MODEL NUMBER BREAK DOWN BELOW FOR OTHER OPTIONS. 4 - 1"-1.5 LB. DENSITY INTERNAL INSULATION. STYLE Al OUTSIDE AIR DAMPER WITH 1" FLANGES STYLE A RETURN AIR DAMPER WITH 1" FLANGES *NOTE* TYP. FOR INDOOR 4.2j USE ONLY i ACCESS PANEL \ STYLE A BOTH SIDES y OUTSIDE AIR DAMPER WITH 1" FLANGES STYLE Al RETURN AIR DAMPER WITH 1" DAMPERS PART NUMBER A B C D E STYLE 6445-MB01-TP-BK-## 18.75 16.75 18,75 12.75 14.75 A 6445-MB01-BK-TP-## 18.75 16.75 18.75 12.75 14.75 Al 64**-MB**-##-##-## I CONTROLS (C-COMPARATIVE ENTHALPY, D-DRYBULB, E-ENTHALPY, N-NONE) ACTUATOR (B-BELIMO, H-HONEYWELL IV-NONE) OUTSIDE AIR DAMPER POSITION-(BK-BACK, LE-LEFT, RI-RIGHT) RETURN AIR DAMPER POSITION TP-TOP LE-LEFT, RI-RIGHT) DOC: 01-01 PROJECT: DATE: ENGINEER: DISTRIBUTOR: DRAWING NUMBER: (((CanFab T E M6 36, 42, 48 , 60 CANNON FABRICATION INC 182 GRANITE STREET, SUITE 101, CORONA, CA 92879 PHONE:(951)278-1830 FAX:(951)278-8444 www.canfab.com canfab®canfab.com PART NO: SEE BELOW STYLE A & Al FEATURES SS-N-2, 1 - FULLY MODULATING HONEYWELL CONTROL SYSTEM AVAILABLE WITH SS-P-1 DRYBULB, SINGLE ENTHALPY OR COMPARATIVE (DIFFERENTIAL) ENTHALPY SENSOR(S) AND HONEYWELL OR BELIMO ACTUATOR. SEE MODEL NUMBER BREAK DOWN BELOW. 2 - HEAVY GAUGE STEEL CONSTRUCTION WITH GALVANIZED FINISH. 3 - RETURN AIR AND OUTSIDE AIR DAMPERS ARE THE SAME SIZE. RETURN AIR SHOWN OPEN, OUTSIDE AIR SHOWN CLOSED AND ACCESS PANEL AS SHOWN. SEE MODEL NUMBER BREAK DOWN BELOW FOR OTHER OPTIONS. STYLE Al 4 - 1"-1.5 LB. DENSITY INTERNAL INSULATION. OUTSIDE AIR DAMPER WITH 1" FLANGES STYLE A RETURN AIR DAMPER WITH 1" FLANGES *NOTE* 5 T'P. FOR INDOOR • 4.2 USE ONLY iS /l 'si <, 4 \ Q STYLE A BOTH SIDES ACCESS PANEL Y/ OUTSIDE AIR DAMPER WITH 1" FLANGES STYLE Al RETURN AIR DAMPER WITH 1" DAMPERS PART NUMBER A B C D E STYLE 6445-MB02-TP-BK-## 18.75 21.75 21.75 17.75 14.75 A 6445-MB02-BK-TP-## 18.75 21.75 21.75 17.75 14.75 Al 64**-MB**-##-##-## I CONTROLS (C-COMPARATIVE ENTHALPY, D-DRYBULB, E-ENTHALPY, N-NONE) ACTUATOR (B-BELIMO, H-HONEYWELL N-NONE OUTSIDE AIR DAMPER POSITION[ (BK-BACK,I LE-LEFT, RI-RIGHT) RETURN AIR DAMPER POSITION TP_TOP 4, LE-LEFT, RI-RIGHT) DOC: 01-01 PROJECT: DATE: ENGINEER: DISTRIBUTOR: DRAWING NUMBER: FEATURES 8411 SERIES MIXING BOXES • FOR SINGLE OR 2 SPEED INDOOR FAN UNITS, OTHER CONTROL OPTIONS CONTROL OPTIONS ARE AVAILABLE TRANE TWE 061-300 II HONEYWELL COMMUNICATING ACTUATOR • EXTERNAL DAMPERS VARIOUS ORIENTATIONS AVAILABLE l CDE W/ DRY BULB CONTROLS • FULL INTERNAL INSULATION. • HONEYWELL JADE W7220 ECONOMIZER CONTROL SYSTEM, (SEE ATTACHED) HONEYWELL COMMUNICATING ACTUATOR CERTIFIED FDD PRODUCT CALIFORNIA TITLE 24, PART 6 HJW10 FCU-N1-4 CEE W/ ENTHALPY CONTROLS • RELIATEL CONTROL OPTIONS ARE ALSO AVAILABLE. TOP/BACK SHOWN • LINKAGE IS SHAKE PROOF WEDGELOCK PLATED STEEL ASSEMBLY STYLE A CBE HONEYWELL COMMUNICATING ACTUATOR TI CONCEALED OUT OF AIRSTREAM w/ DIFFERENTIAL DRY BULB CONTROLS RETURN AIR DAMPER • EXCLUSIVE ONE PIECE AERODYNAMIC DUAL SKIN AIRFOIL BLADES WITH .75" FLANGES HONEYWELL COMMUNICATING ACTUATOR ARE SUITABLE FOR MEDIUM AND HIGH PRESSURE VELOCITY STYLE Al CCE W/ DIFFERENTIAL ENTHALPY CONTROLS j APPLICATIONS OUTSIDE AIR DAMPER •', FACTORY MOUNTED CONTROLS WITH .75" FLANGES I.,/ D 5" 02 n BNN BELIMO ACTUATOR ONLY • MADE WITH GALVANIZED STEEL, PAINT AVAILABLE AS AN OPTION. / ), NOTES: n CNN HONEYWELL COMMUNICATING ACTUATOR 1. STANDARD MIXING BOXES ARE FOR ONLY INDOOR USE ONLY. /K- SVA, & I HDR* RELIATEL ACTUATOR W/DRYBULB 2. RELIEF DAMPER IS NOT SUPPLIED CONTROLS STANDARD BUT IS REQUIRED FOR ASHRAE CA, TITLE 24. THIS CAN BE FIELD CODE n HER* RELIATEL ACTUATOR W/ENTHALPY SUPAN PLIED AND ND INSTALLED, OR AS COMPLIANT Ty.- CONTROLS 3., MOTORIZED, LOW LEAK 4CFM NI / 11 * RELIATEL ACTUATOR W/DIFFERENTIAL ( ) n HCR ADJUSTABLE DRY BULB CONTROLS RELIEF DAMPER IS NOT SUPPLIED STANDARD, BUT IS REQUIRED IF RELIEF IS * RELIATEL EQUIPPED MIXING BOXES INCLUDE REQUESTED IN WA JURISDICTION, FOR WASHINGTON 0 TRANE DAMPER ACUATOR (MOD01301) AND ENERGY CODE THIS CAN BE FIELD SUPPLIED, AND TRANE RTEM (MOD2067), AND ARE TITLE 24 INSTALLED, OR AS AN OPTION. READY WITH THE ADDITION OF OPTIONAL 4. A RELAY IS REQUIRED WITH 2 SPEED INDOOR CONTROL COMPONENTS SUPPLIED BY OTHERS. FAN/HEATPUMP. STYLE A OUTSIDE AIR DAMPER WITH .75" FLANGES rAMCA RATED CLASS 1A MIXING BOXES MEET TITLE 24, 2013 PRESCRIPTIVE ACCESS PANEL ,7----__I ttaaaxaor.ai t- - LEAKAGE RATED HIGH SECTION140.4(E) 4(E) (A,B,C,AND,H), D,E,F, AND G BOTH SIDES \ I I PERFORMANCE DAMPER WHEN SUPPLIED WITH CONTROLS, AND ASHRAE STYLE AlONE-PIECE AIRFOIL BLADE STANDARD 90.1-2010, TABLERETURN AIR DAMPER �c1.114 _.a FOR LOW PRESSURE DROP 6.4.3.4.4 REQUIREMENTS. 5 YEAR PARTS AND WITH .75" FLANGES —— ffi COMPONENTS WARRANTY. DAMPER LIFE CYCLE TESTING DAMPER OPENINGS AND LEAKAGE, RELIEF, SENSOR SET POINT, RELIABILITY, TRANE UNIT CANFAB PART NUMBER A B C D E CFM PD(in w.c.) WEIGHT CALIBRATION, AND HIGH LIMIT. TWE 061 8411-MB01-TP-BK-### 32.5 13 18.5 9.5 29 2000 .037 95 lbs. MIXING BOXES MEET TITLE 24, 2013, MANDATORY SECTION TWE 073 8411-MB02-TP-BK-### 42.5 16.5 22 13 39 2400 .020 130 lbs. 120.2 ECONOMIZER FAULT AND DETECTION DIAGNOSTIC , TWE 090 8411 MB02 TP-BK-; ; , 42.5 16.5 22 13 39 •.I 020 130 lbs. REQUIREMENTS, WHEN SUPPLIED WITH CONTROLS. TWE 120 8411-MBO3 TP-BK-### 58.5 16.5 22 13 55 4000 .017 199 lbs. MIXING BOXES MEET 2012 WASHINGTON STATE ENERGY CODE, TWE 150 8411-MB04 TP-BK-### 74.5 18.5 24 15 71 5000 .011 253 lbs. COMMERCIAL, SECTION C402.4.5.2 OUTDOOR AIR INTAKES AND EXHAUSTS. TWE 180 841 1-M604-TP-BK-### 74.5 18.5 24 15 71 6000 .015 253 lbs. OUTSIDE AIR, RETURN AIR AND, EXHAUST/RELIEF DAMPER TWE 240 8411-MB05-TP-BK-### 83.5 21 26 17 80 8000 .019 293 lbs. (MOTORIZED AND 4 CFM/SQFT ® 1" STATIC OR LESS LEAKAGE) TWE 300 8411-MB05-TP-BK-### 83.5 21 26 17 80 10000 .029 293 lbs. FOR: TRANE TWE 061-300 (((canFab _ **_ CANNON FABRICATION INC PART NO: 841 1 MB TP-BK PROJECT: 182 GRANITE STREET, SUITE 101, CORONA, CA 92879 ENGINEER: DC DISTRIBUTOR: PHONE:(951)278-1830 FAX:(951)278-8444 www.canfab.com canfabOcanfob.com DRAWING NO: 8411 MB.DWG DATE: 02.05.17 APPROVED BY: DATE: / / 8411—MB**—RA—OA—ACO 1 TOP I— CONTROLS (C—COMPARATIVE ENTHALPY,ID—DRYBULB1 E—ENTHALPY, N—NONE) C ACTUATOR (B—BELIMO, J:C:lohlacl N—NONE) AIRFLOW IN MXB BACK OUTSIDE AIR DAMPER POSITION (TP—TOP,1BK—BACK) BO—BOTTOM, LE—LEFT, RI—RIGHT) HORIZONTAL POSmON RETURN AIR DAMPER POSITION I(TP—TOP.IBK—BACK, BO—BOTTOM, LE—LEFT, RI—RIGHT) 1 MIXING BOX MODEL NUMBER STYLE B STYLE C P// TTYLE A P P • BOTTOM AND BACK / I N % ., TOP AND BOTTOM / —BO—BK—## r d TOP AND BACK � I" �� ► \��Y I I —TP—BK—## 4 —TP—BO—## ''/ / L /Y � � STYLE Cl I % �� STYLE Al 1 �i ' , STYLE B1 BACK AND BOTTOM g i '�'I TOP I ' BOTTOM AND TOP g 1 ��� II '_< ,e BACK AND \ 9 �I —BO—TP—## II - s�> —BK—BO—## :a 1/ —BK—TP—## I .- r. i� ACCESS PANEL BOTH SIDES , ACCESS PANEL BOTH SIDES � ACCESS PANEL BOTH SIDES � STYLE D P STYLE E STYLE F RIGHT AND BACK A TOP AND LEFT f LEFT AND BACK \ ✓ I I I —TP—LE—## C '\\ —LE—BK—## —RI—BK—## /I II I;� -r `���. STYLE E1 . ,-- �I STYLE F1 � � STYLE N �I ,AV, i11 B BKK RIN## IPANEL IlACCESSACCESS PANEL ACCESS ,�I /N STYLE G //- STYLE H STYLE I P ', P �!' LEFT AND RIGHT P ''• LEFT AND BOTTOM TOP AND RIGHT .4� —LE—BO—## ly —TP—RI—## \ —LE—RI—## I I1�\\ ����� STYLE H1 /� -L,L -' .-' :I STYLE 11 �I ` STYLE G1 RIGHT AND LEFT N ,pi) BOTTOM AND LEFT ,\\g II I\� RIGHT AND TOP 9 1 I. —RI—TP—## \9�.�� —RI—LE—## ��,�, —BO—LE—## ��, \', � ACCESS PANEL ACCESS PANEL ACCESS PANEL STYLE J /-1), STYLE K (EXHAUST MIXING BOX) RIGHT AND BOTTOM P TWE UNITS ONLY. OUTSIDE AIR DAMPER -RI-BO-## ; /. WITH 1' FLANGES �\�'-. CONTACT FACTORY / STYLE J1 FOR OTHER UNIT �� 4 EXHAusr AIR DAMPER BOTTOM AND RIGHT 9 . OSERIES. t/ WITH 1' FLANGES —BO—RI—## � ACCESS PANEL 94,41 OPTIONAL C DAMPER ORIENTATION i FILTER SECTION AVAILABLE L' +� ONLY AS SHOWN. I CONTACT FACTORY CONTACT FACTORY I/ o FOR OTHER i 9 ACCESS PANEL a9 FLANGES MIXING AS / �P///''/ C ORIENTATION. BOX �/���%� / i BOTH SIDES 4 440, �� ��� RETURN DAMPER RETURN AIR ) / ----.... ,.)..„, --.,,<,--- r WITH 1' FLANGES FOR: TRANE TWE 061-300 eCanFab PART NO: 841 1—MB**—TP—BK PROJECT: CANNON FABRICATION INC ENGINEER: DC DISTRIBUTOR: 182 GRANITE STREET, SUITE 101, CORONA, CA 92879 PHONE:(951)278-1830 FAX:(951)278-8444 www.canfab.com canfabOcanfab.com DRAWING NO: 8411 MB.DWG DATE: 02.05.17 APPROVED BY: DATE: / /