Plans (181) Approvedplans DIVED { L shall be on job site. MAY 2 2019 Di- WEBB RESIDENCE Ct < zLi PH O TO V O LTA I C ARRAY ULDING DIVISION .," 4.41 kW, 14 @ 315W REC/ENPHASE (k ,, „..,.,,,,) ,.• .,,‘,..,..„,O V CUSTOMER THOMAS WEBB 12145 SOUTHWEST 123RD COURT N o0 LIABILITY TIGARD, OR 97223 0 The City of Tigard and its 0 employees shall not be 503-740-3462 cc r'D=y FY W Jj responsible for discrepancies v 1 v which may appear herein. webbhead2@frontier.com t� /�/�(�� . o_ j �3 V� ( , O J J En 0. VV co co a aJW O a- r W oC CONTRACTOR AURIC ENERGY A a' A j 2310 SOUTH 1300 WEST w L\..° a o a° WEST VALLEY CITY, UT 84119 F : ic .- VALIDITY OF PERMIT c3 A THE ISSUANCE OFA PERMIT 801-878-3363 Ell 4 BASED ON CONSTRUCTION k i, ii DOCUMENTS AND OTHER permits@auricsolar.com E c3 I v DATA SHALL NOT PREVENT 0-H „'� a :� THE CODE OFFICIAL FROM 44 Q 4 DATE: 5h2019 REQUIRING THE CORRECTION JOB NO: 177329 OF ERRORS.ORSC 105.4 REVISION NO. 001 DESIGN BY: JR 1 of 7 r— INDEX NOTES: + i t mows :' Sheet Number Sheet Title 1 TITLE 1. ATTACHMENT FEET WILL BE FIELD ADJUSTED TO ACCOMMODATE TRUSS POSITIONS. �"� I 2. 4 FT. MAXIMUM SPACING BETWEEN ATTACHMENT POINTS, AS PER OREGON STRUCTURAL �./ 2 INDEX-LEGEND-MECHANICAL DETAILS&NOTES SPECIALTY CODE, 3111.5.3. Z 3 PLAN LAYOUT 3. RAIL END OVERHANG LIMITED TO LESS THAN 34% OF MAXIMUM SPAN (18 IN MAXIMUM). 11 4. SEE ATTACHED SHEETS FOR SNAP N RACK ULTRA RAIL-40 WITH STAGGERED FLASHED 4 STRING LAYOUT&ELECTRICAL INTEGRATION ULTRA RAIL COMPOSITION L-FOOT BASE DETAILS. 5 SINGLE LINE INTERCONNECTION DIAGRAM&LABELING 5. IF ARRAY IS CLOSER THAN 3' FROM ANY RIDGE, HIP OR EDGE, ATTACHMENT POINTS f, MUST BE 24" O.C. MAX. AS PER OSSC 3111.5.3(1)&(2). t 6 ELECTRICAL CALCULATIONS,NOTES&DETAILS 6. PV MODULES MUST NOT BE INSTALLED OVER OR BLOCK ANY ATTIC VENTS, PLUMBING 1 7 BILL OF MATERIALS VENTS, FURNACE OR WATER VENTS, ETC. 7. ARRAY WIRE MANAGEMENT SHALL BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL ** ELECTRICAL&MECHANICAL EQUIPMENT CUT SHEETS MEANS DESIGNED AND LISTED FOR SUCH USE AND HELD OFF THE ROOF SURFACE. 8. EGC's SHALL BE RUN WITH ASSOCIATED CIRCUIT CONDUCTORS IN ACCORDANCE WITH NEC **SEE ATTACHED CUTSHEETS FOR EQUIPMENT MANUFACTURER SPECIFICATIONS. 690.43(C) 9. INSTALLER TO VERIFY PROPER GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH NEC 250.50. 10. ALL INSTALLATIONS SHALL COMPLY WITH OSSC REGULATIONS, 2015 BUILDING CODES & 2017 NEC. 11.RAIL MIDCLAMPS CAN ONLY BE POSITIONED ±3" OF MOUNTING HOLE. 12.STAINLESS STEEL ATTACHMENTS REQUIRED TO MITIGATE CORROSION. M O N ,N u N N DETAIL A DETAIL B cc Ncn •2 FLASHED L-FDO, FLASHED L-FOOT 0 LU n FLASHING p o •-' O •t � Z a, FLASHED ULTRA RAIL Q eel E COMPOSITION L-FOOT w — J • v, (SEE NOTE 4) U o j w •,3 c a�04 W J .C1 1 4`2 ` U 'o Q m N Z •,-5a, w Q FOR ROOF NU= - ANGLE SEE L u w ,m 11-6"MAX. SHT. 3 .•o SNAPNRACK (SEE NOTE 3) H w . m ULTRA RAIL-40 O o 1a En — c LC) O DETAIL C SNAPNRACK DETAIL D DETAIL E N PORTRAIT ORIENTATION LVDSCAPE ORIENTATION FLASHED ULTRA RAIL BONDING DETAIL m 3'-Vi" Y�" 5'-6° y" REPRESENTS ATYPICAL : COMPOSITION "L" FOOT FOOT PLACEMENT SNAPNRACK fie" 13'-33a"f 1'-6" MAX �jl (SEE DETAIL A) TO FIRST FOOT I I (SEE NOTE 5) ULTRA RAIL-40 �U IM ^ •�_ ml RACKING SYSTEM GINIMIL lh REPRESENTS ATYPICAL � (SEE NOTE 4) I ' OT NOTEEENT In.n_� SNAPNRACK ft. -- ULTRA RAIL 40 Gli 1 MEMO (SEE5) i.. r.I I■■ �A�AI RACKING SYSTEM In (SEE NOTE 4) SOLADECK '11. Il��l1■111111 rrrr■r�Ir In SNAPNRACKSNAPNRACK 111111111111111 ULTRA RAIL-40 �__1'-6" MAX UACKING SYS40M �„ FLASHED ULTRA RAIL EQUIPMENT -- DATE: 5/1/2010 COMPOSITION 'L' FOOT GROUNDINGiJOB NO: 177329 TO FIRST FOOT _ (SEE NOTE 4) (SEE DETAIL A) CONDUCTOR. 6 REVISION NO: 001 MI 1.11.11 4'-0"TYP. STAGGER ATTACHMENT 4'-0"TYP. AWG BARE COPPER WIRE __ SEE NOTES POINTS BETWEEN ROWS SEE NOTES DESIGN BY: a STAGGER ATTACHMENT 1 &2 1 &2 SNAPNRACK GROUND LUG POINTS BETWEEN ROWS (1 PER ROW REQUIRED) 2 of 7 ARRAY SQUARE FOOTAGE NOBS: MAIN SERVICE \� TOTAL ROOF AREA TOTAL ARRAY AREA TOTAL ARRAY COVERAGE ENTRANCE/ UTILITY METER 5 ■�..�. { 1. FIELD ADJUST ARRAYS ON SLOPE FOR BEST �� 2369 253.96 10.72% .ice. PLACEMENT. 2. ALLOW 1' FROM RIDGE AS PER OREGON PV AC COMBINER BOX FIRE CODE. �G ✓ti' T 1 3. STAGGERED ATTACHMENTS REQUIRED. SEE ATTIC ACCESS �/" ,/ PAGE 2 DETAILS C & D. m ° .a • ( ... -0 a y� .✓1 4. TRUSS SPACING IS 24" O.C. (TYPICAL). ATTIC ACCESS ° < �� W !IrRLLi • a •e ARRAY 1 — / 9 MODULES a G (kL...........sa 9\---"--- • \ e a <a 4 OG�� \ OQ• O / / JJ�� WMAIMrioisMAIIsir \ c1 Cl c1 Cl c1 c1 c1 c1 c1 / LOAD CENTER& POINT OF INTERCONNECTION X + 7 t- • ❑ ATTIC ACCESS // Uf /// / Ck.1 / c1 c1 c1 01 \ / /X / o a cc C1 Cl / / O o ARRAY 2 - \ / Y' 5 MODULES / 0 m • 1 6" • / z H- a \ / (?- 3 \ �, g g \ cc m 02 M g LU a / I— \ w II \ if \\ \ / ROOF DESCRIPTION \ / ARRAY ROOF TILT ROOF AZIMUTH TSRF / #1 46' 180' _ 94% /2 18' 180' 87% \ \ / ASPHALT SHINGLE ROOF / REC 315W MODULES JOB NO: 177329 ENPHASE 107-60-2-US \ MICROINVERTERS \ / REVISION NO: 001 V 14 © 315W = 4.41 KW / DESIGN BY: JR SEE ATTACHED SHEET FOR DETAILS SALE No SCALE 3 OF 7 .- D Lu < z LLI ARRAY 1-9 v1ODULESSEERSHEET's f -,, 0 00 O 1 00 . SDI 0 Cl Cl Cl Cl Cl Cl Cl Cl Cl I C M 0 N o� ti Z °iu 29'-105/g rn 0 CC I— -o 0 0 < Na N _ G L�o p C7 ARRAY 2-5 MODULES Q I- cold CD z S CIRCUIT 1 SEE SHEET 5 Z 1 < c>.,:,„, i 0 00 0000 w CC U 4.77 p p FC d3 ui O H ag, ' _ � , w U w �'� 11111-Mil I11� -i� iii s9 w u� 0 LEGEND CO ,� ENPHASEL-j c A MICROINVERTERS w m`o B SOLADECK g D O Z m0 w�' C ® CABLE CONNECTOR N E ,a IA- IN " 69- NOTES: O BRANCH TERMINATIONS a s C I E g JUNCTION BOX R NOTES: 1. MODULES ARE BONDED TO RAILS USING SNAP N RACK BONDING MID CLAMPS. SEE CUT SHEETS FOR DETAILS. 9._1-074 2. ARRAY IS TO BE BONDED TO THE CIRCUIT EGC AT A SINGLE POINT PER ARRAY ROW SECTION WITH A LISTED BONDING LUG USING BARE 6 AWG COPPER. DATE: 51V2019 AS PER NEC 690.43. JOB NO: 177329 3. SEE CUT SHEETS FOR ENPHASE INVERTER CABLING REVISION NO: 001 ACCESSORIES SPECIFICATIONS AND DETAILS. DESIGN BY: JR 4. SEE CUT SHEETS FOR COMBINER/ENCLOSURE SCALE NO SCALE SPECIFICATIONS. 4 OF 7 a NOTES: I„A 1. METER SOCKET ONLY. LOCATED ON NORTH SIDE OF HOUSE. .,�6� (J (EXISTING) Lae cc. 2. 200A RATED INDOOR LOAD CENTER. LOCATED IN GARAGE ON SOUTH WALL. (EXISTING) D w 3. 125A RATED ENPHASE 10 AC COMBINER 3 BOX. (NEW) 4. SOLADECK PV ROOF-MOUNT PASSTHROUGH ENCLOSURE, SUPPLY SIDE INTERCONNECTION AC/DC-SD-786-3R. 705.12(A) < Lii 5. REC 315NP 315W MODULES, ENPHASE 107-60-2-US MICRO-INVERTERS WITH 1.0 POWER FACTOR AT RATED POWER OO 0000 .. AS PER MANUFACTURER, ENPHASE Q CABLE. / '� (( !\'',., ) EXISTING 60A/2P UTILITY —O •• 'M ..✓✓__" SERVICE EXISTING WIRE EXISTING •)NEW 20A/2P SOLAR OCPD REFER TO GENERAL NOTES EXISTING EXISTING LOADS LOADS 10/3 UF-B CD (3/4°CONDUIT O N - `o WHERE NEEDED) r LU w LABELING: 1 •CO o 2017 NEC CODES,ARTICLE 690 Oa 0,5O TO BE INSTALLED AT THE 7-06. M U UTILITY I METER N NEC 705.10 < g PARALLEL ON-SITE _ W I— Q SOLAR GENERATION O 7 O Z D •, E TO BE INSTALLED ON MAIN SERVICE DISCONNECT D (] •� LABEL MUST BE PRINTED IN COLOR AND FONT HEIGHT C AS DEFINED IN NEC 690.56(C)(1)(a) LNL.I v H'- •Nl EM EQUIPPED •)10A/2P ')20A/2P cc D LJJ ) SOLAR PV RAPID SYSTEM p O I OPCD ° NEW SOLAR m M Z "d B I Lu - 0 y A ENPHASE ENVOY Qr- V) IX d= 1 12/3 OF-B = Z ° O (3/4"CONDUIT 12/3 OF-B I— UJ D1 TO BE INSTALLED AT MAIN SERVICE DISCONNECT 3 4"CONDUIT iT WHERE NEEDED) //��"" 0 Z /—OO / WHERE NEEDED) =I RAPID SHUTDOWN SWITCH O �{ N LU 41.0 LOCATED OUTSIDE ON SE 2 2 O L. J ;� SIDE OF HOUSE (.7 u ENPHASE ENPHASE ( Z a a Q CABLE Q CABLE ( ) v TO BE INSTALLED ON PV DISCONNECT / SEE SHEET 4 / SEE SHEET 4 NEC 690.13(8) PHOTOVOLTAIC AC DISCONNECT MAX.AC OPERATING CURRENT:it A OD z , MAX.AC OPERATING VOLTAGE:240 V Z Z_ TO BE INSTALLED ON RAPID SHUTDOWN DEVICE =N NEC 690.56(C)(3) _, E Ld RAPID SHUTDOWN SWITCH O m U CO FOR SOLAR PV SYSTEM in u, DATE: 512019 JOB NO: 177329 TO BE INSTALLED ON PV DISCONNECT, REVISION NO: 001 CONDUIT EVERY WAND WIRY SERVICE NEC 690.31(0)(3)8 690.31(6) O O -WARNING- O 5DESIGN BY: JR PHOTOVOLTAIC POWER SOURCE F OF 7 ' I p , I 1 • , VOLTAGE DROP CALCULATIONS FROM TO VOLTAGE PHASE CONDUCTOR FLA(0,WIRE SIZE LENGTH CIRCULAR MILS(CM)CU/AL CONSTANT(K)VOLTAGE DROP TOTAL VOLTAGE DROP VOLTAGE DROP%TOTAL VOLTAGE DROP% r WORST CIRCUIT(1)(CIRCUIT 1) SOLADECK/JUNCS ON BOX(1) 240 1 CU 5 12 (11 (1) (1) 0.10 0.10 0.04% 0.04% SOLADECK/JUNC110N R BOX(1) SOLADECK/JUNCTION R BOX(1) 240 1 CU 5 12 25 6530 12.9 0.49 0.59 0.21% 0.25% Slim CX SOLADECK/JUNCTI ON R BOX(1) PV AC COMBINER PANEL 240 1 CU 14 12 45 6530 12.9 2.49 3.08 1.04% 1.28% PVUI1UTY DISCONNECT POINT OF INTERCONNECTION 240 1 CU 14 10 40 10383 12.9 1.39 4.47 0.58% 1.86% Darr Li (1) SEE ENPHASE 0 CABLE VOLTAGE RISE TABLE IN CUTSHEET PACKAGE ./� Z Li j 1(ta. 2 >W0.'�a ATTACHMENT POINT DETAIL ` `° GENERAL NOTES: � ,„-, 1. IF REQUIRED,AS PER NEC 705.12(B)(2)(3)(b), LOAD SIDE INTERCONNECTED BREAKERS TO BE INSTALLED AT OPPOSITE END OF BUSBAR FROM INPUT FEEDER. 2. ALL CONDUCTORS SHALL BE 90' C THWN-2 COPPER UNLESS OTHERWISE NOTED. 3. IN OREGON, ANY SYSTEM OVER 7.2kW DC INVERTER OUTPUT REQUIRES A DISCONNECT THAT IS MANUAL, LOCKABLE, LOAD BREAK, HAVE A VISIBLE BREAK, AND BE LOCATED WITHIN 10 FEET OF THE UTILITY METER. IF LOCATED ELSEWHERE,AN APPROVED DIRECTORY DENOTING IT'S LOCATION MUST BE INSTALLED AT THE UTILITY METER. — 4. THE SIGN MUST BE REFLECTIVE, WITH ALL LETTERS CAPITALIZED, AND LETTERS ARE AT LEAST 3/8” IN HEIGHT, WORDING MUST ALSO BE WHITE co o ON A RED BACKGROUND. N N 6,,5 5. VERIFY PROPER GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH ti - D 01 NEC 250.50. CC I-- v a 6. ANY WHITE/NEUTRAL CONDUCTOR USED AS A PHASE CONDUCTOR SHALL 0 Lu N a BE RE-IDENTIFIED USING RED TAPE AT ITS TERMINATION POINTS. TAPE p' CD 5y SHALL BE APPLIED IN ANY LOCATION WHERE CONDUCTOR IS VISIBLE AND L i ACCESSIBLE IN ACCORDANCE WITH NEC 200.7(C)(1). < w ,. 7. ALL ELECTRICAL EQUIPMENT SHALL COMPLY WITH THE WORKING Lu H I— >.N CLEARANCE REQUIREMENTS DEFINED IN NEC 110.26. ° U Z c,5 8. ELECTRICAL EQUIPMENT,CONDUCTORS AND CONDUITS SHALL BE PERMITTEDTO Z a= BE INSTALLED DIFFERENTLY AS SPECIFIED ON ELECTRICAL DIAGRAM IF ° — p Z ce INSTALLATION MEETS NEC CODE AND MANUFACTURER REQUIREMENTS. o a El o 0 0 to OU _O Q o, w F- O w cc cl I�IMM/IIMIIM IMi1. m cC ? u v wwt (NI �wwNwnw 1/IMMI1MIMMIlI MM I— Q Q a w ` °� 1 WI I " I 9 0 ?, —1 rno LEGEND SNAPNRACK ULTRA RAIL - 40 II•IO�N 0 = U (TYPICAL) I■Iwp N D eC `;_ O I�IM.i o o O) CIRCUIT BREAKER !!SIM J D o ATTACHMENT POINTS (43) ww a� SPACED®48"O.C. IMM Lu °u ® — UTILITY DISCONNECT SEE SHEET 2, DETAILS A-D IIII a 7-,_ I I 2X4® 24" O.C. I I I I (TYPICAL) / — FIRE FIGHTER ACCESS O - UTILITY METER Litt O — PRODUCTION METER DATE: 522219 LAD JOB NO: 177329 REVISION NO: 001 1 — GROUND SYMBOL DESIGN BY: JR% 6 - / BILL OF MATERIALS ~ QTY ITEM M DESCRIPTION DESIGN REMARKS FIELD REMARKS •1•••••11 14 REC 315NP REC 315 W MODULES w 14 IQ7-60-2-US ENPHASE 107 MICROINVERTER < L 14 242-92093 SNAP N RACK MLPE RAIL ATTACHMENT KIT L1S 2 053-00225 SOLADECK PV ROOF-MOUNT PASSTHROUGH ENCLOSURE, AC/DC-SD-786-3R ,/ " 1 ` 15 052-10112 ENPHASE 0 CABLES 240 (PORTRAIT); PER CONNECTOR 0 052-10113 ENPHASE Q CABLES 240 (LANDSCAPE); PER CONNECTOR 1 300-07706 ENPHASE Q WATER TIGHT CAP 2 300-07707 ENPHASE 0 BRANCH TERMINATOR 43 242-92266 UMBRELLA LAG, 4" 43 242-01220 ULTRA RAIL UMBRELLA L-FOOT, BLACK 43 242-01375 COMP FLASHING, 9"X12", BLACK ALUM (REQUIRES UMBRELLA LAG) C M o 8 232-02451 SNAP N RACK ULTRA RAIL, 168", BLACK ti N'a u �v 4 242-01214 ULTRA RAIL SPLICE, BLACK O n Psi Lci. 12 232-02452 SNAP N RACK ULTRA RAIL END CAP cC . Q �m E'114 22 242-02054 SNAP N RACK BONDING MID CLAMP, 1.30°, BLACK C3 Ln m Z Q Qa 12 242-02215 SNAP N RACK UNIVERSAL END CLAMP w F- 0 (j w ce <o 3 242-02101 SNAP N RACK GROUND LUG R - 6-12 AWG w� CIOU Q o'� � cnw cc LL u 2 HITCH CLIPS m O E I— y Li, __I <'8 SEE SHT 5 LABELS to m o= W c- 01`0 77, 1 X-IQ-AM1-240-3 ENPHASE IQ AC COMBINER 3,WITH ENPHASE IQ ENVOY H -0 c D > 0 `mO 1 BR220 EATON 20A/2P BREAKER N v a ✓ a 1 00220 SQ D 00 20A/2P BREAKER ° N as v DATE: 5/1/2019 JOB NO: 177329 REVISION NO: 901 DESIGN BY: JR 7 of 7 r t d jr g I r � ,,,,,:kief:',,,.., , -.,,,,,,,,,,,,-,,: 1 .4 , , F ! ' • 4 OFF 31+ E ��, /; - if1 , , , h I • _... "" w ` t. „u ... R't.» •fi x f _ti T.. ', «� r ..Vii_ 'i : * [