Loading...
Permit (181) CITY OF TIGARD MASTER PERMIT 1111 II ' ' COMMUNITY DEVELOPMENT Permit#: MST2019-00173 T-I i_;A Ft D 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/09/2019 Parcel: 2S 110DA04400 Jurisdiction: Tigard Site address: 10788 SW KABLE ST Subdivision: ERICKSON HEIGHTS Lot: 5 Project: Whitaker Project Description: Solar photovoltaic. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $13,886.58 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer: 0 Drains: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add!500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: Y Other Description: Roof Top Soar!PV 7.13 kW Ecompasing: N BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: OTR SF VB R-3 0 Owner: Contractor: WHITAKER,ROBERT D&SHANNON M BLUE RAVEN SOLAR LLC Required Items and Reports(Conditions) POST FAMILY TRUST 1220 S 630 EAST,STE 430 BY POST,GLEN E&MARY M TRS AMERICAN FORK,UT 84003 10788 SW KABLE ST TIGARD,OR 97224 PHONE: PHONE: 385-498-4408 FAX: Total Fees: $358.19 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain copy of the rules or direct questions to OUNC by calling 232.1987 or 1.800.332.2344. Issued By: 1.�7�r,� :i� Permittee Signature: Call 503.639.4175 by 7:00 a.m.for the next available inspection date. / ›.(:) This permit card shall be kept in a conspicuous place on the job site until completion of the• •ject. Approved plans are required on the jon site at the time of each inspection. Buildin2sPermit Application Residential FOR OFFICE USE ONLY 'A - City of Tigard 'ir..',',9 Date/By:Receivel<}1 C�( \"�"' Permit No.c<1c ' Cli— 4 9 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review Phone: 503.718.2439 Fax: 503.598.1960 DateBy: / Z /1 Other Permit: TIGARD Inspection Line: 503.639.4175 „__, `,j Date ReadyBy: 76„n /177uds ® See Page 2 for Internet: www.tigard-or.gov otified/Meth..: / 6„ ` I Supplemental Information / i T \\ ", TXFOF I ( ' 0 DATA -1 D 2\a00, :i .� ao,, ❑New construction LIDemolition Permit fees*are based on the value of the work performed. 3 Indicate the value(rounded to the nearest dollar)of all ❑Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the „, \\ //GORY O O\ TRi-icriQ$ 5- \, T \ work indicated on this application. \� -and 2-family dwellingValuation: $ 13886.58 ❑Commercial/industrial ❑Accessory building ❑Multi-family Number of bedrooms: ❑Master builder EIOther: Number of bathrooms: ”\� C �� o °v°v Total number of floors: �' � ,p-33'' .11"E SIN�'+©Rk�fiTIo1�°, I �,(}+ �I'It7P�' \a� Job site address: 10788 Southwest Kable Street, Tigard, Oregon, 97224, United States New dwelling area: square feet City/State/ZIP: Garage/carport area: square feet Suite/bldg./apt.no.: Project name: Robert Whitaker Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet REQUIRED DATA: OMMERCI .L USE CUECI7 IST"= Subdivision: Lot no.: Permit fees*are based on the value of the work performed. Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the DESCRIPTION Olt .K v .0% work indicated on this application. Rooftop Solar PV Valuation: $ I3I&Q Existing building area: square feet / New building area: square feet Ezi PROPERTY OWNER %!"❑"TENANT Number of stories: Name: Robert Whitaker Type of construction: Address:10788 Southwest Kable Street,Tigard,Oregon,97224,United States Occupancy groups: City/State/ZIP: Existing: Phone:( ) Fax:( ) New: ❑ APPLICANT j CONTACT PEYSSON BUILDINC PERMIT FEES* Business name:Blue Raven Solar (Please refer to fee schedule) Contact name: Lesly Bee Structural plan review fee(or deposit): FLS plan review fee(if applicable): Address: 1220 S 630 E City/State/ZIP: American Fork UT, 84003 Total fees due upon application: Phone:(385482-0045 Fax: :( ) Amount received: E-mail: permitting.deparment@blueravensolar.com PHOTOVOLTAIC SOLAR PANEL-SYSTEM FEES* Commercial and residential prescriptive installation of '' ' CONTRA TO'R" � roof-top mounted Photovoltaic Solar Panel System. Business name: Blue Raven Solar Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address: 1220 S 630 E Solar Installation Specialty Code checklist. City/State/ZIP: American Fork UT, 84003 Permit Fee(includes plan review $180.00 and administrative fees): Phone:(385482-0045 Fax:( ) State surcharge(12%of permit fee): $21.60 ccB lic.:210112 — Total fee due upon application: $201.60 Authorized signature: 742 4 This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Print name: Jeffrey frey Lee Date• 04/18/2019 *Fee methodology set by Tri-County Building Industry I Service Board. I:ABuilding\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB) Electrical Permit Application FOR OFFICE USE ONLY City of Tigard d Received g Date/B : Permit#r 't 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review Phone: 503.718.2439 Fax: 503.598.1960 Related Permit#. ,...'-.2.,\--A TI GARD Inspection Line: 503.639.4175 Ready Date/By: Juris: El See Page 2 for Internet: www.tigard-or.gov Notified/Method: Supplemental Information ,�\ (f t %ri,1 TY OFA;WOK \ , ;\` �,\, ii / \ t`. _\ \ -i \\; /ii \\ \ \, ;* iii.+�,� � K,\W G --a . , . :: ❑New construction ©Addition/alteration/replacement Please check all that apply(submit 2 sets of plans w/items checked): ❑Service or feeder 400 amps or more ❑Building over three stories. ❑Demolition 0 Other: where the available fault current �3� �\� � iii , � DI Marinas and boatyards. / ✓!,$. &T.E lr�oN. lWT-6-$ ice7, O„ exceeds 10,000 am sc at 150 volts or \\ ,,..� / ��� % P ❑Floating buildings. ©1-and 2-family dwelling 0Commercial/1ndustrla1 ❑Accessory building less to ground,or exceeds 14,000 ❑Commercial-use agricultural amps for all other installations. buildings. ❑Multi family 0 Master builder 0 Other: 0 Fire pump. 0 Installation of 150 KVA or :0 � � IQN jjr j ❑Emergency system. larger separately derived 10788 Southwest Kable Street 0Addition of new motor load of system. Job#: Job site address: 100HP or more. ❑"A","E",°°1-2",°°l-3", City/State/ZIP: Tigard,Oregon,97224,United States ❑Six or more residential units. occupancy. 0 Health-care facilities. ❑Recreational vehicle parks. Suite/bldg./apt.#: Project name: Robert Whitaker 0 Hazardous locations. ❑Supply voltage for more than ❑Service or feeder 600 amps or more. 600 volts nominal Cross street/directions to job site: ` /�t\ ��� S(� �E ��� t 1 �mv- ,/-: ✓i, _ � .�.�: \\ : gat ,,\���- Description I Qty. I Each 1 Total I * New residential single-or multi-family dwelling unit. Subdivision: Lot#: Includes attached garage. Tax map/parcel#: 1,000 sq.ft.or less 168.54 4 ,%\\ t\ \\ \\'., ,, } jp (Pj \ \\ % iii /i \�,. Ea.add'1500 sq.ft.or portion 33.92 1 RI - \ : '- \\ Limited energy,residential 75.00 2 Rooftop Solar PV (with above sq.ft.) Limited energy,multi-family residential(with above sq.ft.) 75.00 2 \ Renewable Energy0 ge 2 PtpE1Y�WN " ` TNA \t . o - Services or feeders installation,alteration, and/or relocation Name: Robert Whitaker 200 amps or less 100.70 2 Address: 10788 Southwest Kable Street, Tigard, Oregon, 97224, United StatE 201 amps to 400 amps 133.56 2 401 amps to 600 amps 200.34 2 City/State/ZIP: 601 amps to 1,000 amps 301.04 2 Phone:( ) Fax:( ) Over 1,000 amps or volts 552.26 2 Email: Temporary services or feeders installation,alteration,and/or relocation Owner installation: This installation is being made on property that I own which is not 200 amps or less 59.36 1 intended for sale, lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: Date: 401 amps to 599 amps 168.54 2 EAPPLICANT ,\ �� e C( ,A . PE Branch circuits—new,alteration,or extension,per panel ` A.Fee for branch circuits with Business name: Blue Raven Solar above service or feeder fee, 7.42 2 each branch circuit Contact name: Lesly Bee B.Fee for branch circuits without Address: 1220 S 630E service or feeder fee,first branch circuit 56.18 2 City/State/ZIP: American Fork, UT 84003 Each add'I branch circuit 7.42 2 Miscellaneous(service or feeder not included) Phone:( 385} 82-0045 Fax: :( ) Each manufactured or modular Email: permitting.department@blueravensolar.com dwelling,service and/or feeder 67.84 2 o o Reconnect only 67.84 2 �� LQN 1l'RACTUit2 �� . d ��,�� dPump or irrigation circle 67.84 2 Business name: Blue Raven Solar Sign or outline lighting 67.84 2 Address: 1220 S 630E Signal circuit(s)or limited-energy panel,alteration,or extension. 0 See Page 2 2 Each additional inspection over allowable in any of the above City/State/ZIP: American Fork, UT 84003 Additional inspection(1 hr min) 66.25/hr Phone:(385)482-0045 Fax:( ) Investigation(1 hr min) 90.00/hr Email: permitting.department@blueravensolar.coms--nig /0 Industrial plant(1hr,n;m) 78.18/hr �/,l, Inspections for which no fee is 90.00hr Lic.: 210112 Electrical Lic.: C1214Suprv.Lic.: �e9�� s ecifically listed(h hr min) „ EJA.CTRICAL PERIVIIT FEES i4Co( aSuprv.Electrician signature,required: Subtotal: Print name: Sam Collier Date: 04/18/2019 ❑Plan Review Required(25%of permit fee): State surcharge(12%of permit fee): /tr4 Authorized signature: TOTAL PERMIT FEE: This permit application expires if a permit is not obtained within 180 Print name: Jeff Lee Date: _04/18/2019 * Number of inspections allowed per permit. 1:\Building\Permits\ELC_PermitAppELR_ERE.doc Rev 06/17/2015 440-4615T(11/05/COM/WEB Electrh tl Permit Application—City of Tigard Hue 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: FAStllENTIAVI#fJ SLY: ,��` �\ �9����� '; � .����0°,,,� {t�� Each Qty. � . .� Total ��,.,, I , Description 1 Fee for all residential systems combined: $75.00 Renewable electrical energy systems: Check Type of Work Involved: 5 kva or less 100.70 2 5.01 to 15 kva 1 133.56 2 ❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2 Wind generation systems in excess of 25 kva: Burglar Alarm 25.01 to 50 kva 301.04 2 50.01 to 100 kva 552.26 2 ❑ Garage Door Opener* >100 kva(fee in accordance with OAR 918-309-0040) 552.26 2 ri Heating, Ventilation and Air Conditioning Solar generation systems in excess of 25 kva: System* Each additional kva over 25 7.42 3 Vacuum Systems* >100 kva-no additional charge 0.0 3 Each additional inspection over allowable in any of the above: 0 Other: Solar Panels Each additional inspection is 66.25/hr 1 charged at an hourly(1 hr min) Inspections for which no fee is 90.00/hr specifically listed('h hr min) ����".. ����` �/��� ELS CTRTCAL I'E "" SEES ;C011%IEaE�CI� WURI� .I�L"�� Subtotal(Enter on Page 1): Fee for each commercial system: $75.00 * Number of inspections allowed per permit. (SEE OAR 918-309-0000) Check Type of Work Involved: ❑ Audio and Stereo Systems Boiler Controls Clock Systems Data Telecommunication Installation Fire Alarm Installation HVAC Instrumentation Intercom and Paging Systems ❑ Landscape Irrigation Control* n Medical ❑ Nurse Calls I I Outdoor Landscape Lighting* Protective Signaling ❑ Other: Total number of commercial systems: *No licenses are required. Licenses are required for all other installations 1.\Building\Permits\ELC_PennitApp_ELR_ERE doe Rev 06/17/2015 y City of Tigard 11 Building Division 13125 SW Hall Blvd, Tigard, OR 97223 Phone: 503.718.2439 Fax: 503.598.1960 T I G A R D Inspection Line: 503.639.4175 0 2 H19 www.tigard-or.gov 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 10788 Southwest Kable Street, Tigard, Oregon, 97224, Unite City: Zip: Owner's Name: Robert Whitaker Date: 04/18/2019 Contractor's Name: Blue Raven Solar CCB #: 210112 Design Parameters of the Property/Structure If"Yes", does not Flood Hazard Is the installation Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? p No OSSC or ORSC for design requirements. Wind Exposure Is the wind exposure 0 Yes If"Yes", qualifies for "C" or less? No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes 12 Yes the prescriptive path. and/or their accessory Ground structures. I I No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? If"Yes", qualifies for structures other than DI Yes the prescriptive path. above No 1 I:/Building/Forms/PhotoVoltaic-Checklist02-01-11.docx Is the construction material wood and does D Yes Type of If"Yes", qualifies for the construction qualify Construction as "conventional light n No the prescriptive path. frame" construction? Is the spacing 24 inches or less? Pre-engineered trusses. D Yes If"Yes", qualifies for the prescriptive path. n No Roof framing members Is the spacing 24 inches or less? Nominal lumber. If"Yes", qualifies for D Yes the prescriptive path. n No Is the combined weight p Yes of the PV modules and If"Yes", qualifies for racking less than or n No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance Yes with Section 305.4(3) of If"Yes", qualifies for the 2010 Oregon Solar I No the prescriptive path. Code? Metal Single layer If roofing material is Roofing Check the type of n of wood one of the three types material roofing material shingle/shake checked, qualifies for Max. two layers the prescriptive path. 0 of composition shingle. Is the roof mounted p Yes Connections of solar assembly the solar assembly connected to roof If"Yes", qualifies for I No the prescriptive path. to the roof framing or blocking directly? 2 I:/Building/Forms/Photovoltaic-Checklist02-01-11.docx ❑ Yes If"Yes", qualifies for Is the gauge 26 or less? n No the prescriptive path. 115 lbs for 60 inch spacing or less? If"Yes", qualifies for n Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for n Yes the prescriptive path. ❑ No Attachment of roof mounted Minimum 24 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 directlyto inches inches, qualifies for the Maximum 60 inches prescriptive path. standing seam metal panels Width of roofing If the width of the panel panels? 18 inches or less is less than 18 inches, inches qualifies for the prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of ❑ If"Yes", qualifies for fastener? Yes the prescriptive path. ❑ No Is the roof decking of WSP min. '/2" thickness, Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12" o/c? Is the hi e ght less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for solar modules module to the roof Yes the prescriptive path. surface. ❑ No 3 I:Bu i lding/Forms/Photo V oltaic-Checkl ist02-01-11.docx Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing (rafter size, type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: Jin KO Model Number: 23 Listing Agency: CSA 4 I:/Building/Forms/Photovoltaic-Checklist02-01-11.docx City of Tigard Tel: 503.718.2439 Location: Inspection Date: 10788 SW KABLE ST, TIGARD, OR, 97224 Record Type: Record ID: Residential - Master Permit MST2019-00173 Inspection Type: Inspector: 199 Electrical final David Young Result: PASS Comments: Violation Summary: Inspector Contractor City of Tigard Tel: 503.718.2439 Location: Inspection Date: 10788 SW KABLE ST, TIGARD, OR, 97224 Record Type: Record ID: Residential - Master Permit MST2019-00173 Inspection Type: Inspector: 299 Final inspection David Young Result: PASS - NoCofO Comments: System appears ok per approved plans. No access to roof top panels. Violation Summary: Inspector Contractor