Loading...
Plans (110) FMN A3-IBT-400-240-MPU MPU-EDA HER(MUA-E2) � \^- FAN#1 (MUA-E2) - HEATER PERFORMANCE CURVES. 8 X INDIRECTFIBENT. TUBE GAS FIRED HEATER WITH 24'DIRECTADRIVE FFM,1 P). STA, LESSTSTEE FULL MODULATION,CONSTANT L.J, rte(' eyt „�(' EXC.EFFICIENCY,AND 61 MAX TURNDOWN FIR NG,(SQ MAX TURNDOWN FOR LP). STAINLESS STEEL BURNER AND HEAT W✓l.J�L1 EXCHANGER. 2. DEKD ICAO WITH FILTERS a SIDE DISCHARGE-AIR RIGHT->LEFT � ^�'t - 4.SEPARATE 120V ELECTRICAL,CAL CONNECTION FOR ALL IBT HEATERS WITH I MODULE FOR STANDING POWER. 120V MUST BE RUN Il ) Q . 4500 CFM, 3.024 SP @ 1466 RPM and 6.304 BHP at 174 feet and 10 degF BY ELECTRICIAN FROM BUILDING PANEL TO MJA SNITCH. ■Please note that these curves were adjusted for Job speclf lc temperature and altitude. 5.CASLIN(BUILDING MONITORING SYSTEM COMMUNICATIONS MODULE.REQUIRES INTERNET 6 FIELD WIRED ETHERNET CONNECTION OR 3G CELLULAR SERVICE. INCLUDES REV 3 COMM MODULE,RJ45 TO MODBUS CONVERTER,3 FT CATS CABLE,AND 1 FT OF SHIELDED TWISTED PAIR. 6.MOTORIZED BACK DRAFT DAMPER 30'X 30'FOR SIZE 3 STANDARD 1 MODULAR HEATER UNITS V/EXTENDED SHAFT,STANDARD GALVANIZED CONSTRUCTION,3/4'REAR FLANGE,LOW LEAKAGE, NFBUP-S ACTUATOR INCLUDED 4.000 7.GAS PRESSURE GAUGE,0-35',2.5'DIAMETER,1/4'THREAD SIZE N 8.GAS PRESSURE GAUGE,0 TO 410 INCHES VG,2.5' \DIAMETER,1/8'THREAD SIZE,REAR THREAD \, y \ ,� \\ 9.10 TON,DUAL CIRCUIT(5/5)MODULAR PACKAGED AC COOLING OPTION FOR SIZE 3 MODULAR PACKAGED UNIT. INCLUDES CONDENSER,DX COIL,FILTER/DRYER KIT,THERMAL EXPANSION VALVE,R4IOA REFRIGERANT.AND REFRIGERANT PIPING (1500 TO \. \ \ 4000 CFN) NOT BUILT WITH OPPOSITE SIDE CONTROLS OR OPPOSITE AIRFLOW DIRECTION. CONDENSERS REQUIRE SEPARATE 3.500 4 \\ \ 460V,3 PHASE POWER SUPPLY UNLESS ORDERED WITH SINGLE POINT CONNECTION COIL=3EZ1203T � \ 10.INSULATED BLOWER HOUSING SIZE 3 COMMERCIAL MODULAR `.S / 11.3 YEAR EXTENDED WARRANTY FOR FAN MOTOR. PARTS OFLYI DOES NOT INCLUDE LABOR. \ 12.COOLING INTERLOCK INPUT TO PCB BOARD. LOCKS OUT BURNER CIRCUIT WHEN AC IS ENERGIZED. 4i \\ 13.SUPPORT SHELL FOR SIZE 3 MODULAR PACKAGE UNIT. INCLUDES CONTROL VESTIBULE. INCLUDES CONDENSER SUPPORTS. '\ .. \ - \ !2 DOES NOT INCLUDE RETURN AIR OR INLET AIR DAMPER. \\ / Ss 97 14.FULL CRATING FOR COMMERCIAL HEATERS FOR SHIPPING 3.000 Q N 15.MPU3-10-AC MOISTURE ELIMINATOR OPTION-ALLOWS COOLING COIL FACE VELOCITY TO INCREASE TO 650 FPM. INCREASES \ 'M;0. q COOLING COIL MAX CFM TO 4550 CFM. % \ \ 3 \ "r 16.MERV 13 FILTER OPTION FOR SIZE 3 MIXING BOX OR CONDENSER SUPPORT. MIXING BOX OR CONDENSER SUPPORT MUST BE \ SELECTED FOR THIS OPTION.USES 4 15 X 20 X 2 INCH FILTERS AND 2 15%15 X 2 INCH FILTERS. N \ 17.DISCHARGE FIRESTAT. SET TO 240•F 10 VAV(VARIABLE-AIR-VOLUME)WIRING PACKAGE FOR COMMERCIAL FANS. 2.500 / \ 0-10VDC SPEED CONTROL VARIABLE FREQUENCY DRIVE INCLUDED '\ 19.VFD FACTORY MOUNTED AND WIRED ON UNIT CONTROL PANEL SUPPLY SIDE HEATER INFORMATION, / \.\ 20 MOUNT LOAD REACTOR IN FAN. IBT-US Patent 877119 B2 WINTER TEMPERATURE=10'F. TEMP.RISE=50'F. l„d' \\\ ` BTUs CALCULATED OFF ACTUAL AIR DENSITY S P 2.000 \ NOTE.SUPPLY DUCT MUST BE INSTALLED TO MEET SMACNA STANDARDS.A MINIMUM STRAIGHT DUCT LENGTH MUST BE MAINTAINED OUTPUT BTUs AT ALTITUDE OF¢ / a, \\ 0 ft.-273643 'O DOWNSTREAM OF UNIT DISCHARGE UNLESS OTHERWISE SPECIFIED.DO NOT RELY ON UNIT TO SUPPORT DUCT IN ANY WAY. INPUT BTUs AT ALTITUDE OF 00 ft..342054 \ FAILURE TO PROPERLY SIZE DUCTWORK MAY CAUSE SYSTEM EFFECTS AND REDUCE PERFORMANCE OF THE EQUIPMENT. OUTPUT BTUs AT ALTITUDE OF 174 ft.-271927 / • • \• SUGGESTED STRAIGHT DUCT SIZE IS 30'x 30'x 108'LONG. 7 1/4JNPUT BTUs AT ALTITUDe OF 174 ft.-339909 ,/ \ ♦ r 6 1/2' ,JD J- 1.500 / • \ d • 0,,. \ , '* r AIRFLOW «- ��� AIRFLOW ' �'�� � 1,000 ,��\ \ COOLING 11\/ J/ \ ����I MODULE I • RAM \\ \\\ II 0.500 \ \-., SrST 61 yp \ �-- �� 0.000 "N, S I 9' REX essr sm 1'MPT CZNECIIM FOR 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 7500 8000 SS PITCHED DRAIN PAN CFM 241' 57 3/4' 60' 45 1/8' 42 1/8' 42 1/8' T-IMH:0131Z`le:a\ 'CLAD.NSH R 21 ! . I's FLIRIAACE-N. 12 5'e FLBDNCE VENTS VENTS - _ 1013r A �q �yrj' ��/�j\f 18 1/2' STRAI DUC T wB M 8 •m \ I ;��J Pe 16..r' I--7 27 1/2' ` N1 a ® e it L n10[RECT F1ED NDYLE0SER AMSLDWAPR 2 9 2019 31' 57 1/16' 0 nlllECT .11 ... COD_ ® DCINDENSER ISCONNECT ~.7 MII SNITCH ��56 3/8' ACCE I I r 1'MT OMR F AIRFLOW r‘1,•41, e 0 OF fl MI\s,Lf . L / BLOVER/IOTO! L- --10ee-r . a OR 2 A SEG' o H� .® Elam, BUILDING Nemb � ii. 4 / DIVISION E 11.11Raliie 4 _ T 20' 143/1'' 20'EQUIPMENT CURB I I^ I -11_IL 35'� I 186 3/16' C0NDENSHR DETAILS fM WIT TAG FM UNIT NOBEL• TSD( FIN NO N TRMACf VOLTAGE PHASE FREQUENCY MCA Rl,t SIZE SIZE SEER Typkol Drx6 Trap 1001011 8.YO. end.d Cooling CoA Dram Trap CaFlpratlon t 401E-E2 A3-IBT-400-24D-IPU I 5 460 3 PHASE 60 Hi l0.]Nps BS MOS 1]Inge 14 AVG 14 2 5 460 3 RAISE 60 He 109 Nps 85 Nps IS Nps 14 AVG 14 IlNoru 7' 1111A-RAN/NPORMATION-106/9524 89 Clean• 7 Out FMN IO( DESIGN COOLING COIL COOLING COD-CORING CDD_C A OIG CDD_COOLING COIL OILING 0481 C1nL COOLnN COIL,,,„m,T BUfeElt W[T TAG FAN UNIT ROTEL• SLIVER HGISDG CFI, CiM ESP, UPN HP. BMP. 0 VRT M ENTERING BB ENTERING VB LEAVING DB LEAVING VB TOTAL SENSIBLE LATENT SONES - 1G TEMP. TEM. TEM. TEMP. CAPACITY CAPACITY CAPACITY (LDS') EFTIC@EY03 F-12'Mln 1 -E2 A3-IBT-400-240-tPU 24W-3-MORA3-OIC - 4500 1.500 1466 10500 6.3040 3 460 122 BUT 67.0' 626E 582' 1200 MN 1260 NMI 0.0 MBH 2907 15 80 IR / �� IRB✓$yAIMW TFU APRI FM '� MIT TAG BTUs WIPUT TOP.RISEREWIRE°MUTF"SS GAT TYPE Nl I� Motto MM-E2 339909 271927 50 deg F 7 66..c-14 In ee. Nowa) 2)UseeonlyylPoe low proille coml'0.PVC only PAN 'naffs 3)Add an qas sham FMN Nsham MIT TAG MTI134(City.-Deem.) NO. _ t-Standard Electrical Cornecton(mann and control panel)for Standing Poser -S)n Med.le. If a Non-DCV Pr..Y,b used an tne IIT Heater,the i28,047, starter In PreA'e sew'be selected Do not provWP apply 1-CASl16 Building monitoring System-Internet or Cellular Connection Rewind 1-Notarized Backdroft Damper for A3-I Housing 1-Inlet Pressure Gauge,0-35' 1-NanKdd Pressure Gauge,0 to 10'es,1 Furnace I-10 Ton 2 Circuit(5/5)ModAar Packaged AC Cooling Lipton for Size 3 NIA (1500 to 4000 cfn).460V.3 phase. Cooling Thermostat cr Prtprarnnble Stet RepeFed for Proper Operation -Insulated Mower Section SF..3 Comerclol Nodular 1 MUA-E2 -3 Year Extended Motor Varnonty -AC Interlock 24VAC-IBT/RTU -Condemer Support for Mae 3 Mod Pac1oge IML -Fall Crating For Comserdal Heater - PU3-10-AC Moisture EIYJwtar Option-Cloys cooling coil face ve(odty to Increase to 610 fon. Increases cooling col rax cfn to 4550 cf.. - CRY 13 filter option for Size 3 Nixing Box or Condenser Support. Ming Bax or Carxlenser Support oust be selected for this option. -Recharge FIeStat Set to 240E IBT/RTU -VAV Packag.e/0-10VDC Input Control(571 WI)Include& -VFD factory mounted and*Neel M corner-dal control vestbole for IBT -Load Reactor Mounted In Fen S Na Fµ TAG WEIGHT REN SIZE 1 ••1 1411A-E2 150 LBS Carl 3S000N x 186.300'L 0 20.000')) Insulated $0 ND JNPOE1&T! FAN MIT NITER RPM LVA 3IeES IBA DISi/VKE OCTAVE 1 OCTAVE 2 OCTAVE 3 OCTAVE 1 OCTAVE] OCTAVE 6 OCTAVE 7 OCTAVE 8 HII 1 SCO Oy 1466 7)9 15 66.3 5 739 00.4 778 742 7L7 69 - 668 642 0• Ind Fired Bent Tube Htr Wiring-Jr-1B 3524689 - Apex Lab Expansion Cooling Upgrade •�•� DRAWING NUMBER IBT3524689-1 SHIP DATE 1/8/2019 MODEL A3-IBT-400-24D-MPU ! . . - 1 Installed Options 1 2 SW-01 VFD LR-02 o-BK -J °21 mT1 Al A2 Discharge Firestat 3 0--aK_-4 °� :� Bl B2- MT-01 RD__-4 8 �e Cl C2 GR CASLink 0(120VAC\ — o J U CAT 5 RJ45 R545 CB-01 4!ATTENTI❑N ELECTRICIAN! TO J4 I EOL . DROP FOR DISCONNECT CONNECTION 0- >=15HP USE RS485 Component Identification IS FACTORY SUPPLIED WH (1\11) ,TO MODBUS CONVERTER Label Description Location CONNECT POWER TO THE DROP CB-01 10A Circuit Breaker S201U-K10 [3] B H 01 e J9-(1) IBT-01 J9-(8) 0 N nJ COM-01 Communication Module [6] 5 coM-oi �I ed+. Mo' Fa QEl BK J17 � � � � M o • FR-01 Flame Rod 1 [8] C7 :BT�4Ro MT-020 6 YY WH J21 1 2 3 4 FSC-01 Flame Safety Controller 1 [8] Fla.DI WIRED PR J7—(9) CON HERRNET VA-01Co) YW J7- 5 �; II ( ) LR-XX Line/Load Reactor [3] FSC-01 MT-01 Supply motor [2] MT-02 Power Vent 1 [5] 7nix Si PSW PR J7-(1) YW MT-04 Motorized Damper Motor [19] Sirti HV TH J7-(2) G IND BR J7-(3) 8 V1 GY J7-(4) FR-01 IGNITOR V2 WH J7-(18) rpim BK WH`, nl L BK J7-(11) 9R RD J7-(12) PS-01 Vent Proving 1 [11] 120 J7-(10) BL aTR-04 SW-03 BL J7-(15) PS-09 Airflow Proving Switch [22] 10 RD GY BR J7-(17) PS-11 24VDC Power Supply 18W [6] - SW-04 BR J7-(16) NOo cJ7-(13) "2 VA-05 °b°PS-01 - J7-(14) 11s/ BK SHIELDED WIRE BK J7-(8) ! �� J7-(7) RJC-01 RS485 to Cat5 Converter [6] RD `1 \X X RD J7-(6) 12 J15-(1) RDQ3 ill SN 03 Intake Temperature Sensor [12] J15-(2) BK SR--_09_, SN-06 Discharge Temperature Sensor[14] 13 BLIBL 'CONDENSER 1 O-—--off CRL1 — • SBL •11 21• B r9 10 BL ` SW-01 Main Disconnect Switch [3] 14 J3 J15-(7) F. --) -SN-O6 o- � •13 2 • COMP1 SW-02 Damper End Limit Switch [19] To J2 J15-(8) BK r 3 PHASE • COIL • SW-03- RolliOutSwitchSwitch 1 [10] On Local 460 GY YW HMI 1 nilin O RC 0 15 SW-08 DX Float Switch [18] SW-09 40A Rotary Disconnect [19][21] �� J22-(1)GY Y1 ORAS •IRD ACONDENSER 2 J4 J22-(2)" 10 RC 0 o-d 7� ; ARD •11 210 TR 04 ModrVal�ee1 Transformerrsme40v �] 16 _. \\ To VFD J23-(1)" Y2 01 o-� RD •13 2 •• OMP2 3 PHASE 0 COIL • VA-01 Main Gas Valve 1 [6] J23-(2)'(W 10 RC 0 460 YW VA-05 Modulating Gas Valve 1 [10] 17 I® Y2el ORC0 MOTOR INFO SUPPLY 10HP-460V-3P-12,2FLA 18 J18-(4)- SW-08 VFD PART: ESV752NO4TXB571 J18-(11) d N 0 W DM SW-02 BK J9-(4) 19 MT-04 WHIS1°/OS30 EL 01 J9-(5) J14-(6)--- 0-10VDC INPUT FOR VFD SPEED CONTROL , 0------I® Fel J9-(3) J14-(7)--- 0-10VDC COMMON ELECTRICAL INFORMATION 20 FIRE INPUT TRIPS UPON 120V DETECTION MOTOR CIRCUIT MCA: 15,3A CONTROL CIRCUIT MCA: 4,1A MOTOR CIRCUIT MOP: 25A CONTROL CIRCUIT MOP: 15A = 21 COND2 MCA = 10.5A 0 5A CONDI. MOPMO =115A J11-(5)--o24VAC A/C INTERLOCK � J13-C GY J13-(6) 22 PS-09 YW J13-(13) J11-(8)--024VAC COMMON C o 0 NOTES I`"'--dt -——- DENOTES FIELD WIRING 23 DENOTES INTERNAL WIRING FIELD WIRED CONTACTS Z C' H m BK WH I0 N J16-(5)--o UNIT INTLK G)7sIN, rin 24 J16-(6)--0 24VAC NFTER&I AFL SERIESS S4 NACTUATORD S6 S ON 120 2-v 9TR-03 WIRE COLOR 'CL SOCKET STYRELAY °24 BL BC BL J13—(14) BK - BLACK YW - YELLOW RD - RED w 4 3 25 RD0 BP RD J13-(7) BL - BLUE CR - GREEN WH - WHITE "C 2 1 _ ♦ BR - BROWN GY - GRAY r:< _ iPl COIL 8 7 i ; • E- - BRANuE PR - PURPLE 6 5 VFD Wiring • JOB 3524689 - Apex Lab Expansion Cooling Upgrade `• DRAWING NUMBER VFD3524689-1 SHIP DATE 1/8/2019 MODEL A3-IBT-400-24D-MPU Installed Options 1 2 SMV 571 SERIES VARIABLE FREQUENCY DRIVE TERMINAL FUNCTION • 3 Component Identification 1 Digital Input:(Start/Stop) 11 Internal DC Supply for External Devices 4 2 Analog Common 30 Analog Output: Configurable with P150.,,P155 5 To J4 on RJ45 IBT Board 6 EOL RJ45 7 RESIST❑R 8 •q PE Ground Terminal L1 3 Phase Input or Single Phase Input POWER SUPPLY L2 3 Phase Input or Single Phase Input 9 L3 (N) 3 Phase input (Neutral for 120v) U 3 Phase AC Motor 10 MOTOR V 3 Phase AC Motor W 3 Phase AC Motor 11 SUPPLY DRIVE PARAMETER SETTINGS* EPM PROGRAM, IBT 571 12 P100 (Start Source) = 01 (Terminal Strip) All external control wires to motor speed control should P102 = **Minimum Frequency (Hz) be 16-20 AWG shielded multiconductor cables and must not P103 = **Maximum Frequency (Hz) be run In the same conduit or raceway with any high power P150 (TB-30 Output) = 1 13 wiring. Ground Shielded Cable at the drive chasis ONLY. P194 (Password) = 225 P410 (Modbus Address) = 21 PG. 11 OF THE DRIVE MANUAL DESCRIBES THE PROPER Adjust manually on all drives 14 INSTALLATION PROCEDURE P107 - 00 (If 120 or 208 VAC) or 01 (If 230, 480 or 575 VAC) PG. 19 OF THE DRIVE MANUAL DESCRIBES THE PROGRAMMING P108 - Motor FLA x 100 / Drive Output Rating PROCEDURE OF THE DRIVE P165 (Base Voltage) = Set to Motor Voltage (Preset@230V) P165 FOR STANDARD DRIVE ONLY PG. 23 OF THE DRIVE MANUAL DESCRIBES THE PARAMETER P167 (Base Frequency) = Calculated Per Fan 15 SETTINGS OF THE DRIVE *NOTE' THE DEFAULT PASSWORD FROM THE FACTORY REQUIRED TO PROGRAM THE DRIVE IS '225'. IT MAY BE REQUIRED TO FULLY POWER DOWN THE DRIVE MOTOR INFO 16 AND TURN BACK ON IN ORDER TO INITIATE NEW SUPPLY 10HP-460V-3P-12,2FLA PARAMETER SETTINGS. VFD PART: ESV752N04TXB571 **Min, and Max. Frequency Settings override all other Preset speeds/Parameters. 17 18 e ELECTRICAL INFORMATION MOTOR CIRCUIT MCA: 15,3A CONTROL CIRCUIT MCA: 4.1A MOTOR CIRCUIT MOP: 25A 19 CONTROL CIRCUIT MOP: 15A CONDI MCA = 10,5A CONDI MOP = 15A COND2 MCA = 10,5A COND2 MOP = 15A 20 C C) NOTES 21 ---- DENOTES FIELD WIRING J° 0 DENOTES INTERNAL WIRING -r b.5 rn WIRE COLOR 22 GENERAL NOTES c9 BK - BLACK YW - YELLOW Q BL - BLUE GR - GREEN m 3r�*� BR - BROWN GY - GRAY O' OR - ORANGE PR - PURPLE RD - RED - 23 WH - WHITE • •• i •.� •• . i�,,' Installation Wiring . JOB 3524689 - Apex Lab Expansion Cooling Upgrade ',��� DRAWING NUMBER RP3524689-1 SHIP DATE 1/8/2019 MODEL A3-IBT-400-24D-MPU 2 e _ Installed Options 120 V 1 PH, 240 V 1 PH. 208/460/600 V 3 PH. Disconnect Disconnect Disconnect Switch Switch Switch Gal-flex Gal-flex Gal-flex conduit conduit conduit (in unit) . Cin unit) . `� (in unit) , e or sr ar \ Factory \ Factory Factory wiring wiring wiring ,� ® ® ® ® I® ® ® ® _i I® / Customer Customer Customer BK WH GR supplied BK RD GR supplied BK BK B r GR wiring supplied pp wiring wiring 460V 3PH Disconnect Switch Gal-flex conduit (in unit) s Factory i�, wiring 1C1 BL BL B RD RD RD ,GR Customer supplied CONDENSER 1 CONDENSER 2 wiring DO NOT CONNECT CONDENSER POWER DROPS TO KITCHEN CONTROL PACKAGE STARTERS OR VFDS I siimiionummimmr Power Connection See above details. lk •'••................................: i Condenser:S e eo Not t i o A b O V e ,,,,,,,,,,44 • 4• •• • • •, •• •• i • • O 0 1i O CAT-5 CONNECTIONS ON REVERSE MENU J3 ON HMI1 to J2 OF I+112I2 I( BE DAISY `Oi4ED IDLLE ED �Oi PLACEMAX FENDAOFIL NE DEVICE INN LAST HMI CHAINED 0 (\, a NOTES FAN ON 1 r SET PT O ^ ———BUILT—IN TEMPERATURE SENSO \ CO 0 t \ --....MOUNTS IN STANDARD '� DOUBLE GANG JUNCTION BOX 2 0 t. m WIRE COLOR a-1 t� BK - BLACK YW - YELLOW fir r' < BL - BLUE GR - GREEN I� rn BR - BROWN GY - GRAY ?D OR - ORANGE PR - PURPLE RD - RED PK - PINK ,s0. WH - WHITE "�