Loading...
Permit (161) CITY OF TIGARD MECHANICAL PERMIT COMMUNITY DEVELOPMENT Permit#: MEC2019-00245 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/01/2019 T I i;A I.1) g Parcel: 2S102BA00304 Jurisdiction: Tigard Site address: 9824 SW TIGARD ST Project: Barrier Corporation Subdivlslon:RTH TIGARDVILLE ADDITION,AMENC Lot: 22 Project Description: Warehouse unit heater replacement with new gas piping. Contractor: ARROW MECHANICAL Owner: TIGARD INDUSTRIAL LLC 10330 SW TUALATIN RD 5845 JEAN RD TUALATIN, OR 97062 LAKE OSWEGO, OR 97035 PHONE: 503-692-1565 PHONE: FAX: 503-691-1879 FEES Specifics: Description Date Amount Type of Use: COM Mechanical Permit-COM 04/18/2019 $288.69 Class of Work: ALT Type of Const: VB Plan Review-Mechanical 04/18/2019 $72.18 Occupancy Grp: B Occupancy Load: 12%State Surcharge-Mechanical 04/18/2019 $34.64 Stories: Info Process/Archiving-Sm$0.50(up to 04/18/2019 $4.00 Project Valuation: $7,808.00 11x17) Fuel Air Handlers Fuel Types: Natural Gas Units<10000 cfm: Gas Pressure: Units>10000 cfm: Furnaces Boilers&Compressors Furnaces<100K BTU: 1 0-3 HP: Furnaces>=100K BTU: 3-15 HP: Floor Fumaces: 15-30 HP: Unit Heaters: 30-50 HP: Vents w/o Appliances: 50 or Greater HP: Air Conditioning: Heat Pump: Appliances Vent Fans: Vent Systems: Total $399.51 Hoods: Comm Incinerators: Required Items and Reports(Conditions) Woodstoves: Gas Fireplaces: Clothes Dryers: Other Mech Units: Gas Outlets: Other Desc: Duct Work: Fire/Smoke Dampers: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may,,obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987%1.800.332.2344. Issued By: / ermittee ignature: Call 503.639.4175 by 7:00 a.m.for the next available inec ion date. This permit card shall be kept in a conspicuous place on the job site until/ completion of the project. Approved plans are required on the job site at the time of each inspection. Mechanical Permit Annlication^ Reye, City of TigardECEDate/BY: '/ f /j`f . Permit N°.: �1i v?d 1/-1:)1, r5' Ill13125 SW Hall Blvd.,Tigard,OR 97223 2019 _ Plan Revi Phone: 503.7182439 Fax: 503.598.1960 9 Daher Permit. r i , t w.n Inspection Line: 503.639.4175 �P X eDate/Be. loci _ 2 for Internet: www.tigard-or.gov c,�r 01- 1.,:n, ,,ed/Method liate Ready/By:- mss Supplem0 See ental laformatiau Via/ /G1 y TYPE OF wow ?,,:4.,0.+4. M *Wittrtni--lIfte(nE Mechanical permit fees*are based on the value of the work ❑New construction C.4 Addition/alteration/replacement performed.Indicate the value(rounded to the nearest dollar)of all Q Demolition 0 Other. mechanical materials,equipment,labor,overhead,and profit. Value:$$7,808.00 CATEGORY OF CONSTRUCTION Iff,S DID TTAL EQUIPMENT/SYSTEMS FEES* ❑1-and 2-family dwelling ®Commercial/industrial ❑Accessory building For special information use checklist ❑Multi-family 0 Master builder 0 Other. Description Qty. Ea. Total JOB SITE INFORMATION AND LOCATION Heating/cooling: Air conditioning 46.75 Job site address:9824 SW Tigard Street Furnace 100,000 BTU(ducts/vents) 46.75 City/State/ZIP:Tigard,OR 97223 Furnace 100,000+BTU(ducts/vents) 54.91 Suite/bldg./apt no.: Project name:BarrierHeat pump 61.06 Corp Duct work 23.32 Cross street/directions to job site: Hydronic hot water system 23.32 Residential boiler(radiator or hydronic) 23.32 Unit beaters(fuel-type,not electric), in-wall,in duct suspended,etc. 46.75 Flue/vent for any of above 2332 Subdivision: I Lot no.: Other. 23.32 Other feel appliances: Tax map/parcel no.: Water heater 23.32 DESCRIPTION OF WORK- Gas fireplace/insert 33.39 Flue vent for water heater or gas Like-for-like replacement of one existing warehouse unit heater. fireplace 23.32 Replace existing gas line for one existing unit heater and one existing gas pack Log lighter(gas) 23.32 Wood/pellet stove 33.39 with new gas piping. Wood fireplace/insert 23.32 _ Chimney/liner/flue/vent 23.32 0 PROPERTY OWNER I -. TENANT Other: 2332 Environmental exhaust and ventilation: Name:Barrier Corporation Range hood/other kitchen equipment 33.39 Address:9806 SW Tigard St. Clothes dryer exhaust 33.39 City/State/ZIP:Tigard,OR 97223 Single-duct exhaust(bathrooms, toilet compartments,utility rooms) 2332 Phone:(503)639-4192 Fax:( ) Attic/crawlspace fans 23.32 ® APPLICANT 0 CONTACT PERSON Other. 23.32 Fuel piping: Business name:Arrow Mechanical Contractors $14.15 for first four;$4.03 for each additional Contact name:Joe Chamberlain Furnace,etc. Address:10330 SW Tualatin Rd Gas heat pump Wall/suspended/unit heater City/State/ZIP:Tualatin,OR 97062 Water heater Phone:(503)692-1565 Fax::(503)692-1879 Fireplace . Range E-mail:arrovvinech@,frontier.com Barbecue CONTRACTOR Clothes dryer(gas) Business name:Arrow Mechanical Contractors Other. MECHANICAL PERMIT FEES* Address:10330 SW Tualatin Rd Subtotal City/State/ZIP:Tualatin,OR 97062 Minimum permit fee($90.00) Plan review(25%of permit fee) Phone:(503)692-1565 Fax:(502)692-1879 State surcharge(12%of permit fee) CCB lie.:5193 TOTAL PERMIT FEE T his permit application expires if a permit is not obtained within 180 Authorized Si Ore: days after it has been accepted as complete.. x /Xignat Fee methodology set by Tri-County Building Industry Service Bond Print name:Joe Chamberlain Date:5-18-19 BlioildieglPen sitstMEC PormitApp 040113_doe 440-4617T(11/02/CON/WEB)