Plans (91) Approved plans OFFICE COPS' shall be on job site. R� . SHENG RESIDENCE ce 1/ 0 er = MqR PHOTOVOLTAIC ARRAY c,Ty �( (, vQ IGgRO 5.67 kW 18 @ 315W REC/ENPHAsIoN HAii CUSTOMER RAN SHENG 16899 SOUTHWEST FRIENDLY LANE N- o N 00 VALIDITY OF PERMIT BEAVERTON, OR 97007 ) cc a,' THE ISSUANCE OF A PERMIT O Na BASED ON CONSTRUCTION 971-770-4958 U r v �- Q c n DOCUMENTS AND OTHER W °a DATA SHALL NOT PREVENT U z THE CODE OFFICIAL FROM s h i n e ra n@ mail.c o m z .3 •' cQ o Z &3 g wQ � am REQUIRING THE CORRECTION OF ERRORS.ORSC 105.4J ~ o� A �r z z CC v N g 0 LUla w I CONTRACTOR AURIC ENERGY .0 w A 2310 SOUTH 1300 WEST 44 ° o o° O CAT" cs) o.a WEST VALLEY CITY, UT 84119 2 801-878-3363 " .. LIABILITY .. The Cityof Tigard and its permits@auricsolar.com w ? 'E .. employees shall not be gi 4 O ;. 'Q (A p DATE: 3/22/2019 responsible for discrepancies JOB NO: 177163 REVISION NO: 001 which may appear herein. DESIGN BY: MH 1 °F 7 INDEX V 7- NOTES: "=Men 0 Sheet Number Sheet Title Law M 1 TITLE 1. ATTACHMENT FEET WILL BE FIELD ADJUSTED TO ACCOMMODATE TRUSS POSITIONS. '`'"� ' 2. 4 FT. MAXIMUM SPACING BETWEEN ATTACHMENT POINTS, AS PER OREGON STRUCTURAL ..../ 11.1 2 INDEX-LEGEND-MECHANICAL DETAILS&NOTES SPECIALTY CODE, 3111.5.3. Z 3 PLAN LAYOUT 3. RAIL END OVERHANG LIMITED TO LESS THAN 34% OF MAXIMUM SPAN (18 IN MAXIMUM). Lit 4. SEE ATTACHED SHEETS FOR SNAP N RACK ULTRA RAIL-40 WITH STAGGERED FLASHED 4 STRING LAYOUT&ELECTRICAL INTEGRATION ULTRA RAIL COMPOSITION L-FOOT BASE DETAILS. ®,,,o. 5 SINGLE LINE INTERCONNECTION DIAGRAM&LABELING 5. IF ARRAY IS CLOSER THAN 3' FROM ANY RIDGE, HIP OR EDGE, ATTACHMENT POINTS f MUST BE 24" O.C. MAX. AS PER OSSC 3111.5.3(1)&(2). t(f( a 6 ELECTRICAL CALCULATIONS,NOTES&DETAILS 6. PV MODULES MUST NOT BE INSTALLED OVER OR BLOCK ANY ATTIC VENTS, PLUMBING [ 7 BILL OF MATERIALS VENTS, FURNACE OR WATER VENTS, ETC. 7. ARRAY WIRE MANAGEMENT SHALL BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL ��,r 8-22 ELECTRICAL&MECHANICAL EQUIPMENT CUT SHEETS MEANS DESIGNED AND LISTED FOR SUCH USE AND HELD OFF THE ROOF SURFACE. 8. EGC's SHALL BE RUN WITH ASSOCIATED CIRCUIT CONDUCTORS IN ACCORDANCE WITH NEC 690.43(C) 9. INSTALLER TO VERIFY PROPER GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH NEC 250.50. 10. ALL INSTALLATIONS SHALL COMPLY WITH OSSC REGULATIONS, 2015 BUILDING CODES & 2017 NEC. 11.RAIL MIDCLAMPS CAN ONLY BE POSITIONED ±3" OF MOUNTING HOLE. 12.STAINLESS STEEL ATTACHMENTS REQUIRED TO MITIGATE CORROSION. N` 0 0 I-- co `oo cc a,E, my DETAIL A DETAIL B 0 to o RASH')L-FOOT MSC)1-FOOT 0 W N a FLASHING cC o 2tw .„ FLASHED ULTRA RAIL > ,,,5ma COMPOSITION L-FOOT w w Ln (SEE NOTE 4) Z CO Q >' ¢_ 4. CI g LU 5m a o LU J foo A. CC Q 0aa, to ` J UU v0 LU W Q D� FOR ROOF (_/) LCL W o m ANGLE SEE I— M En` 1'-6" MAX. SHT. 3 LL 1 X �o SNAPNRACK (SEE NOTE 3) LU -o m ULTRA RAIL-40 = I— Z 0,, 8 ao DETAIL CDETAIL D DETAIL E 2.Y SNAPNRACK co a n PORTRAIT ORIENTARON LANDSCAPE ORIENTATION BONDING DETAIL C) v 3 33C Y FLASHED ULTRA RAIL 5'-6K" 2 REPRESENTS ATYPICAL 3 ° � COMPOSITION "L" FOOT FOOT PLACEMENT SNAPNRACK y" a 7 i r I (SEE DETAIL A) MAX TO FIRST FOOT (SEE NOTE 5) ULTRA RAIL 40 T m� �AIn m RACKING SYSTEM 'n-r1, ,^ REPRESENTS ATYPICAL (SEE NOTE 4) "__ FOOT PLACEMENT °„ - ��� SNAPNRACK ' MEMO ULTRA RAIL 40C t (SEE NOTE 5) � � RACKING SYSTEM ! -, : I (SEE NOTE 4) SOLADECK — rU UMU MI MIN ��� SNAPNRACK M FLASHED SNAPNRACK ULTRA RAIL r•__ � ULTRA RAIL-40 EQUIPMENT DATE: 3222019 6" MAX � RACKING SYSTEM COMPOSITION "L" FOOT GROUNDING �■■ JOB NO: 177163 IE-E M TO FIRST FOOT A (SEE NOTE 4) (SEE DETAIL A) CONDUCTOR. 6 J�l�■■ AWG BARE REVISION NO: 001 a' o"TYP. STAGGER ATTACHMENT a' X"TYP. COPPER WIRE __ DESIGN BY: MH SEE NOTES POINTS BETWEEN ROWS SEE NOTES STAGGER ATTACHMENT 1 &2 1 &2 SNAPNRACK GROUND LUG POINTS BETWEEN ROWS (1 PER ROW REQUIRED) 2 °F 1 7 - NOTES: ARRAY SQUARE FOOTAGE 1. FIELD ADJUST ARRAYS ON SLOPE FOR BEST .TOTAL ROOF AREA TOTAL ARRAY AREA TOTAL ARRAY COVERAGE U C� PLACEMENT. 1449 322.02 22.22% l CY 2. ALLOW 1' FROM RIDGE AS PER OREGON Luso ARE CODE. / GARAGE ENTRY D. a 3. STAGGERED ATTACHMENTS REQUIRED. SEE / PAGE 2 DETAILS C & D. d adallk 4. TRUSS SPACING IS 24" O.C. (TYPICAL). a ° < 11.1Z �. PROPOSED LOCATION ° �ill FOR EV CHARGER //// , INDOOR LOAD CENTER & I //(r(�/!Jl ,1� POINT OF INTERCONNECTION I I t� t MAIN SERVICE tt _ ENTRANCE/ UTILITY METER 'I � � PV AC COMBINER BOX I I I ATTIC ACCESS- I o I I I I I 1'-O" t--- O ❑ ❑ c N- a) `o �� 0) r O1 Cl / zO 0:2 a 1 O cc 04- MIL U ARRAY 1 - I Cl Cl Q 2.94 c 9 6 MODULESI w W 'u) 4U 00 ca Cl 4 ,,cii .,„ p QZ O �LIJ _i Q 0N/ I ARRAY 4 -Ct / 2 ' c`;i 1 17 MODULES -1-1 Z va a ARRAY 2 I-1-1 LLI CL _ Q o 2 MODULES // ❑ N u_ °— rn5 cp ARRAY 3 - 9' ro / ill o d H 1 (n •y 3 MODULES 1 -- I �� p/ 2 2 U U 1- p O' 0 O" N o u coI (/ Ill' 1 0) 1 i CD ROOF DESCRIPTION ARRAY ROOF TILT ROOF AZIMUTH TSRF #1 26 180' 92% I a I #2 49' 270' 74% I I #3 49' 270' 74% - #4 49' 90' 73% d • ASPHALT SHINGLE ROOF 4 '° • Q v DATE: 3125/2019•REC 315NP 315W MODULES ° JOB NO: 177163 ENPHASE IQ7-60-2-US MICROINVERTERS REVISION NO: 001 16899 SOUTHWEST FRIENDLY LANE DESIGN BY: MH 18 ® 315W = 5.67KW SEE ATTACHED SHEET FOR DETAILS SCALE:NO SCALE 3 of 7 ARRAY 1-6 MODULES u Low - AY 1 < L, -6 1 00 SEE SHEETS III 1 1 00 ARRAY 2-2 MODULES /9„- _:,,, CIRCUIT 2 SEE SHEET 5 00 ( O ,, ". .......................... , � 0 p (( 1 0 100 011. 6'-7y" o © o cn 0 Z taa 0 o 2 0 Na . cc 0 L+-, 6_7y„ L1J UL 5 v I— 10L Lu w — n N W — > Wco LIT U Q-0 ARRAY 3-3 MODULES 0 Z � .: ARRAY 4 7 MODULES w Q W J O, tr >-J J( nN C3 p W U ami CIRCUIT2 CIRCUIT 2 LEGEND w w DY SEE SHEET 5 00 0 Oj SEE SHEET 5 A 1 ENPHASE MICROINVERTERS N LL 0 'f0 00 N O 1�J ra- 0 C••. ' 00 B so SOLADECK D a m 1 �, a 00 I u = Z �o, O C ® CABLE CONNECTOR a o D O BRANCH TERMINATIONS � a` O © E JUNCTION BOX R co © lig NOTES: 1. MODULES ARE BONDED TO RAILS USING SNAP N 1 RACK BONDING MID CLAMPS. SEE CUT SHEETS FOR 6'-7y" 6' T DETAILS. 2. ARRAY IS TO BE BONDED TO THE CIRCUIT EGC AT A SINGLE POINT PER ARRAY ROW SECTION WITH A LISTED BONDING LUG USING BARE 6 AWG COPPER. DATE: 3/22/2019 AS PER NEC 690.43. JOB NO: 177163 3. SEE CUT SHEETS FOR ENPHASE INVERTER CABLING REVISION NO: 001 ACCESSORIES SPECIFICATIONS AND DETAILS. DESIGN BY: MH 4. SEE CUT SHEETS FOR COMBINER/ENCLOSURE SCALE NO SC/LE SPECIFICATIONS. 4 of 7 NOTES: > 1. METER SOCKET ONLY, LOCATED ON WEST SIDE OF HOUSE. (EXISTING) °'X/1 2. 225A RATED INDOOR LOAD CENTER, SQUARE D HOMELINE, LOCATED IN O GARAGE. (EXISTING) LOAD SIDE INTERCONNECTION LIM1 W 3. 125A RATED ENPHASE IQ AC COMBINER 3 BOX. (NEW) 00 ©OO 705.12(6)(2)(3)(6) SII/ 4. SOLADECK PV ROOF-MOUNT PASSTHROUGH ENCLOSURE, AC/DC-SD-786-3R. 5. REC 315NP 315W MODULES, ENPHASE 107-60-2-US MICRO-INVERTERS WITH 1.0 POWER FACTOR AT RATED POWER AS PER MANUFACTURER, ENPHASE 0 < W CABLE. 6. INSTALL JUICE BOX EV CHARGER AS PER INSTALLATION MANUAL, TO BE .... , LOCATED INSIDE CUSTOMER GARAGE. E ((I( l/ tEXISTING 200A/2P O rUTILITY —OM o.• SERVICE EXISTING WIRE OCPD \\\\"`\\\\\\,,,,�,� •)50A/2P ')30A/2P NEW OCPD • NEW SOLAR 8/3 OF-B OR REFER TO (2)8AWG GENERAL NOTES (1)8AWG NEUTRAL (1)10AWG EGC EXISTING LOADS 1"CONDUIT MIN. WHERE APPLICABLE N- C> EV CHARGER 0 0 c LABELING: 1 (1)1OAWG NEUTRAL O 0 J ' 2017 NEC CSCODES,ARTICLE / CC (L Nu TO BEwsTAusDATTHE SEE NOTE 6 (1)6AWG EGC O CO D y UTILITYI METER 3/4°CONDUIT MIN. O < N a NEC 705.10 00 I— ° `o° PARALLEL ON-SITE f M W < .L+u SOLAR GENERATION OA TO BE INSTALLED ON MAIN SERVICE DAOMNECT LU W LD Sy LABEL MUST BE PRINTED IN COLOR AND FOHEIGHT V m Q >a1 M Q-a AS DEFINED IN NEC 690.56(C)(1)(8) O O LZ SOLAR PV in ZZ LU 3 Ti SSpNiQUMN O Q6O Uv'20A/2P '20A/2P J w O v° NEW SOLAR ° NEW SOLAR ,1,:: . W Z Z j z TO BE INSTALLED ON PA DISCONNECT rc U .:-C O NEC 69013♦B) 12/2 OF-B 12/2 OF-B N W W m PHOTOVOLTAIC AC DISCONNECT (3/4" CONDUIT OF (3/4"CONDUIT CT)~ = Ola MAX.AC OPERATING CURRENT:18 A CO WHERE NEEDED) WHERE NEEDED)O LU Zvc MAX.AC OPERATING VOLTAGE:240 V O L4.1IO = Z_ , o 12/2 OF-B OF-B 1— - mcc TO BE INSTALLED ON RAPID SHUTDOWN DENCE 4NED 690.%(q(a) �O 0 (3/4"CONDUIT O /T2/2 (3/4"CONDUIT F ASO W O a� WHERE NEEDED) WHERE NEEDED) Cl) C7 2 u RAPID SHUTDOWN SWITCH O sD so so sD Z_ a w FOR SOLAR PV SYSTEM ENPHASE ENPHASE ENPHASE ENPHASE 0 N Q CABLE 0 CABLE Q CABLE Q CABLE to TO BE INSTALLED NEXT TO BACK-FED BREAKER NEC 70E12(B)(2)l3l(b) SEE SHEET 4 SEE SHEET 4 SEE SHEET 4 SEE SHEET 4 ©WARNING / / POWER SOURCE OUTPUT CONNECTION co co co co DO NOT RELOCATE E W w w THIS OVERCURRENT DEVICE w cr Cc cc TO BE INSTALLED ON PV DISCONNECT, f z ? `,? `v z CONDUIT EVERY 10'AND UTILITY SERVICE ,y N ~N NEC 690.31(G)(3)8690.31(B) w' v w w U 0 U 2 <J U 2 G 2 WARNING- O o o 0 0 DATE: 325/2019 PHOTOVOLTAIC POWER SOURCE F `n "" JOB NO: 177163 TO BE INSTALLED AT MAIN SERVICE DISCONNECT REVISION NO: 001 RAPID SHUTDOWN SWITCH O O O �O DESIGN BY: MH LOCATED OUTSIDE ON OG WEST SIDE OF HOUSE 5 DF 7 VOLTAGE DROP CALCULATIONS FROM TO VOLTAGE PHASE CONDUCTOR FLA(I)WIRE SIZE LENGTH CIRCULAR MILS(CM)CU/AL CONSTANT(K)VOLTAGE DROP TOTAL VOLTAGE DROPVOLTAGE DROP%TOTAL VOLTAGE DROP% w maw Q.) WORST CIRCUIT(1)(CIRCUIT I) SOLADECK/JUNCTION R 80X(1) 240 1 CU 6 12 (1) (1) (1) 0.35 0.35 0.15% 0.15% SOLADECK/JUNCTION R BOX(1) PV AC COMBINER PANEL 240 1 Cu 6 12 50 6530 12.9 1.19 154 0.49% 064% (. - PVACCOMBINER PANEL POINT OF INTERCONNECTION 240 1 CU 18 10 5 10383 12.9 0.22 176 0.09% 0.73% . FROM TO VOLTAGE PHASE CONDUCTOR FLA(I)WIRE SIZE LENGTH CIRCULAR MILS(CM)CU/AL CONSTANT(K)VOLTAGE DROP TOTAL VOLTAGE DROP VOLTAGE DROP%TOTAL VOLTAGE DROP% WORST CIRCUIT(1)(CIRCUIT 2) SOLA DECK/1UNCTI ON BOX(1) 240 1 CU 3 12 (1) (1) (1) 0.17 0.17 0.07% 0.07% z SOLADECK/JUNCTION R BOX(1) SOLADECK/JUNCTION R BOX(2) 240 1 CU 3 12 10 6530 12.9 0.12 029 0.05% 0.12% SOLADECK/JUNCTION R BOX(2) SOLADECK/1UNCTI ON R BOX(3) 240 1 CU 10 12 5 6530 12.9 0.20 0.49 0.08% 0.20% < 111 SOLADECK/JUNCTI ON R BOX(3) PV AC COMBINER PANEL 240 1 CU 12 12 65 6530 12.9 3.08 3.57 1.28% 1.49% PV AC COMBINER PANEL POINT OF INTERCONNECTION 240 1 CU 18 10 5 10383 12.9 0.22 3.79 009% 1.58% J�ir„� (1) SEE ENPHASE 0 CABLE VOLTAGE RISE TABLE IN CUTSHEET PACKAGE N/:"�. X A hi GENERAL NOTES: ATTACHMENT POINT DETAIL w` g �� ir 1. IF REQUIRED, AS PER NEC 705.12(8)(2)(3)(b), LOAD SIDE 3, INTERCONNECTED BREAKERS TO BE INSTALLED AT OPPOSITE END OF BUSBAR FROM INPUT FEEDER. 2. ALL CONDUCTORS SHALL BE 90' C THWN-2 COPPER UNLESS OTHERWISE NOTED. 3. IN OREGON, ANY SYSTEM OVER 7.2kW DC INVERTER OUTPUT REQUIRES A DISCONNECT THAT IS MANUAL, LOCKABLE, LOAD BREAK, HAVE A VISIBLE BREAK, AND BE LOCATED WITHIN 10 FEET OF THE UTILITY METER. IF LOCATED ELSEWHERE, AN APPROVED DIRECTORY DENOTING IT'S LOCATION MUST BE INSTALLED AT THE UTILITY METER. O 4. THE SIGN MUST BE REFLECTIVE, WITH ALL LETTERS CAPITALIZED,AND O) g LETTERS ARE AT LEAST 3/8" IN HEIGHT, WORDING MUST ALSO BE WHITE 0) `o:.' ON A RED BACKGROUND. FO J 5. VERIFY PROPER GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH NEC 250.50. Z (a— O n I 6. ANY WHITE/NEUTRAL CONDUCTOR USED AS A PHASE CONDUCTOR SHALL O LU o 0 I BE RE-IDENTIFIED USING RED TAPE AT ITS TERMINATION POINTS.TAPE w .6 . , SHALL BE APPLIED IN ANY LOCATION WHERE CONDUCTOR IS VISIBLE AND > N 2 m ACCESSIBLE IN ACCORDANCE WITH NEC 200.7(C)(1). LU w� ''m 7. ALL ELECTRICAL EQUIPMENT SHALL COMPLY WITH THE WORKING U CO p ca CLEARANCE REQUIREMENTS DEFINED IN NEC 110.26. Z Z 8. ELECTRICAL EQUIPMENT, CONDUCTORS AND CONDUITS SHALL BE PERMITTEDTO w w N Q BE INSTALLED DIFFERENTLY AS SPECIFIED ON ELECTRICAL DIAGRAM IF g 10 Z 0 g rn INSTALLATION MEETS NEC CODE AND MANUFACTURER REQUIREMENTS. I I I � I♦I i ' LU > H o + 1 + _ C.'3 p LJ 1 I T 1 I -- I 2X4 ® 24" 0.C. Z Z D cc y 1 T T (TYPICAL) _ E _ 1 Q 3 A <n w U 5f0 T o LEGEND , } f_. 1 = E 'o p I I -• H W v o CIRCUIT BREAKER . 1 / O _ 1 a_ O -�-�-�-�-- Cn w ou ® --- f-�- C v — UTILITY DISCONNECT CO SNAPNRACK ULTRA RAIL-40 / (TYPICAL) / /• — FIRE FIGHTER ACCESS ----fr-.--•-•- ATTACHMENT POINTS (62) SPACED ® 48" 0.C. O — UTILITY METER SEE SHEET 2, DETAILS B-D ONE O — PRODUCTION METER DATE: 3/22/2019 LOAD JOB NO: 177163 REVISION NO: 001 — GROUND SYMBOL DESIGN BY: MH 6 OF 7 BILL OF MATERIALS QTY ITEM # DESCRIPTION DESIGN REMARKS FIELD REMARKS l E ct 18 REC315NP REC 315W MODULES Dr w 18 107-60-2-US ENPHASE 107 MICROINVERTER Z LiJ 18 242-92093 SNAP N RACK MLPE RAIL ATTACHMENT KIT o SOLADECK PV ROOF-MOUNT PASSTHROUGH ENCLOSURE, g 4 053-00225 AC/DC-SD-786-3R / � � 24 052-10112 ENPHASE Q CABLES 240 (PORTRAIT); PER CONNECTOR (C 1' t 0 052-10113 ENPHASE Q CABLES 240 (LANDSCAPE); PER CONNECTOR �.-- 6 300-07706 ENPHASE 0 WATER TIGHT CAP 4 300-07707 ENPHASE Q BRANCH TERMINATOR 62 242-92266 UMBRELLA LAG, 4" 62 242-01220 ULTRA RAIL UMBRELLA L-FOOT, BLACK . ti 62 242-01375 COMP FLASHING, 9"X12", BLACK ALUM (REQUIRES UMBRELLA LAG) p ` rn o:3 11 232-02451 SNAP N RACK ULTRA RAIL, 168", BLACK O j v N 0 242-01214 ULTRA RAIL SPLICE, BLACK 'O OZ ON a 0 `oy 40 232-02452 SNAP N RACK ULTRA RAIL END CAP w Y u > m c 16 242-02054 SNAP N RACK BONDING MID CLAMP, 33-45mm (1.30-1.77"), BLACK V CO v, Z LU E a n 40 242-02215 SNAP N RACK UNIVERSAL END CLAMP O_ Z w 3 N Q Q am 11 242-02101 SNAP N RACK GROUND LUG R - 6-12 AWG � J m 2 w LL U� 4 HITCH CLIPS = w O a a N LCL m o= SEE SHT 5 LABELS N 2 o Lu w T 1 X-IQ-AM1-240-3 ENPHASE IQ AC COMBINER 3, WITH ENPHASE IQ ENVOY 'O C _ ao 1 HOM230 SQ D HOMELINE 30A/2P BREAKER O v (I) oN V 2 BR220 EATON 20A/2P BREAKER o_ co 1 JUICEBOX PRO40 EV CHARGER 0 1 HOM250 SQ D HOMELINE 50A/2P BREAKER DATE: 3/25/2019 JOB NO: 177163 REVISION NO: 001 DESIGN BY: MH 7 OF 7 1 I • , . . , - - ' • -- -- - - .-. , - ---: -.- __., ..... _ . . ....., .. ... - -,. ,, "1,7 ,...... . .', •.— .' ...,, '..,.- .,.x,rareorsay.,.....,.. . w...,..e......: ' ,. ., -Sir* .......-- ...- -... __.„..,_ ..... ...... .'' ......1,.. „ 1 -..... ..,.1 .. , _,..„.„,.. ...........„. ..„..„,.. ...-......„.._ _,.... , . .._., •--,/'''- i2,,,,,' .:,-. -3-• .:-,.:,--.-:,, .. . ... ,,. ... ... - ' - . —- - -_,-'f..: ',,,,,,c:',!...,,..i.,:',,;;I:15-?,.•-i,'-‘,-;=,!,.---'''''''''''- - , ,.„. ...„. . . .,..-:„ . ....„ -.-_-,_____,..-------- . —..... ,..-..-„, • . --.--_,. -•-1;:ii.: _.-,,-,.--------- - -,..„--- --..- " ' =--, .. . .-..........-..=.......,,... , , .-• .„, --,.....,, ,....- 4 , _ ! . ,, .z1,,,-:„4-:. ...... : ' ' : . ,4 ),.,..,,,4• 1 - , = 4,7'.*L , - . 41,-, i r ;,,-,,- - . ,.. . _ 1 .. „.. „.. ._ .... . . 4 , ) , ,,.,.,. . ... , . „,..,. . . it li..,. ..„, .., AR. 1 - $11iir -:I' —"I-II.'r:III-'"III -,I, -a . . lf,, 1:'-.I-t'Il , . , '-'..".IIITII: ...,..,...,. ' •_—_,,-.. —. _ , . , , ...... . .. , . . . — --— . R1,0 w f :•. , i , ._-. ' . ,„,. V 114'!'!- -f- -1-•S: . ,j,'., 1 ,*t- V gg.gi g t MM A It t P;t4,. TI I-- -,;-„-- ,,,,,,,„.', ; I •'- r',..,,f 1 3011 ' II _ _ ,Vg -_ .1 trig7 • _',...__ : I -1 .,,,,'--. : ,•,..; .,_ 41 I • : ',„;',.',1';i.,--.-..'...,, .1 --:;- - ---.--,*116- - ,•', ', - ..-.-.-4 . .,.. . 0 . - „.- , ..„----- 1 - - .t=iit - = — I -, .',.---, 5.':---._ ---,- r - ,_ .... , ... _ 1 ..... .„ ,..... ,_ .. ._ ... _ . ... ...,,, ..., .. , , .........., .,. _.......,-3! . ig:"',.." g '. . _ :.-..-_,-.1'...1:•.*.t.t..,..A. .,.‘t%-f,t... le :i.-4:_,;,14,-,_ i --i-,..7. ,, 4,2'.4.,i',,,,,', ' • , .,:!...'t-Mit! ti..?--...,:ittla.g.TtION.-14'..4.iret ',,,',;:;it;‘",', ._-...- ,.. , - .- -, ,- ' .• - " ' ' :-1--,t,?,A4.! -g,-,,,.,-f'ttt,,....vil...t..t..-4-&-t--.,,,,o4s.,...• ,.....:_: . ,..,,,.. ...., ......„. .......,„ . . . . + <„ ',„ w t= 6 :s• ,01,.1.:''''''''''''''''i'i* '' � irielli. �v' Fes" ,' ':''''.':,,,.- .,',',.'4..,...,:,,. :::,,,,:fot,'...',;,..'„'', ,'.. x `^^ p Ate ``w� d 60 � �w;tree m yy H.:::=2,.1',' -e "4 w.v✓ k,''4T k-"k°x3 i* 1�'w'S` ` � y$1+ g Iii '..+, .'v3~�wZw ' Px 40 e ENGINEERING Wednesday, March 20, 2019 RECEIVED Auric Solar MAR 2 6 2019 2310 S 1300 W CITY OF TIGARD West Valley City, UT BUILDING DIVISION RE: ROOF EVALUATION FOR 16899 SOUTHWEST FRIENDLY LANE, BEAVERTON, OREGON As per your request I evaluated the support system for the proposed solar array for the residence located at 16899 Southwest Friendly Lane, Beaverton, Oregon. It is my understanding that the roof structure consists of pre-engineered trusses at 24" o.c. where the solar panels will be located. The snow load is less than 50.0 psf and the wind load is less than 120 psf. The roof will be supporting 18 solar panels. Oregon Structural Specialty Code (OSSC) 2014 Section 3111.5.3 indicates that solar panels that are installed on conventional light-framed construction with pre-engineered trusses or roof framing members with a maximum spacing of 24" O.C. shall qualify as prescriptive and shall not require an engineered design. I can be reached at 435-654-6600 extension 123 with any questions. Respectfully, 0.0 PRop .4, 1 we' � ' 'a G 1 N E.6.Q ' , -5r �► qv. 1 ORE 4. i \ '!rylr 9. 20.\ , /20/19 EXPIRES: 1413cet Adam Huff, S.E. Epic Engineering, P.C. Heber City,UT 435-654-6600 West Valley,UL 801-955-5605 Williston,ND 701-774-5200 Killdeer,NI) 701-764-7131 Vernal,UT 435-781-2113 Mesa,AZ 480-309-6504 www.epiceng.net 0