Report (61) ` \G-of Ski. t.,.8 L• . ,f Honeywell VISTA°-250FBPT RECEIVED COMMERCIAL PARTITIONED FIRE AND BURGLARY MAR 2 0 2019 ALARM CONTROL PANEL CITY OF TIGARD BUILDING DIVISION _ . *l1r. The new VISTA-250FBPT provides the ultimate protection for Some of the applications supported are: medical and life and property.This UL listed commercial fire and burglary professional buildings, churches or synagogues, office control panel supports up to eight partitions and up to 250 buildings, schools, strip malls, larger residences and factory zones/points using hardwired, wireless and V-Plex® or warehouse environments. addressable technologies. A diverse line of Honeywell VISTA 250FBPT is compatible with a wide range of initiating devices, notification appliances, communication AlarmNet®communications products for alarm reporting, devices, keypads, RF receivers and relays are also supported. uploading/downloading and Honeywell Total Connect" The VISTA-250FBPT control is well suited for a variety of Remote Services. applications as an integrated fire and burglary control. FEATURES • Eight hardwired zones standard, •Accommodates 250 user codes •Supports graphical user interfaces expandable to 250 using V-flex and up to 500 access card holders for burglary use(e.g. 6280 and addressable points/zones using VISTAKEY® Tuxedo Touch') •Supports up to 250 wireless zones •Supports V-flex addressable •Supports 6160CR-2 multi-LED (fewer if using hardwired and/or VISTAKEY access control fire keypad V-flex zones) (1 to 15 doors) • Upload/download via AlarmNet® •Can control eight separate areas •Two on-board NAGS delivering a Communicators independently(8 partitions) total of 2.3A @ 12V • Carbon monoxide(CO) • Common lobby partition—auto arm •Automatic smoke detector sensitivity zone support or disarm based upon assigned maintenance testing •On board serial port for partitions • Four-wire smoke reset using communication with WIN-PAK®, • Master partition—used for viewing on-board Form C relay Pro-Watch®and approved status of all partitions •Supports Dynamic Signaling for third-party applications • Supports commercial wireless fire AlarmNet Communicators • Supports Total Connect and burglary devices Remote Services* •Supports Internet and GSM •Stores up to 1000 events alarm reporting *Event reporting and control of burglary partitions only. VISTA®-250FBPT Honeywell COMMERCIAL PARTITIONED FIRE AND BURGLARY ALARM CONTROL PANEL ADDITIONAL FEATURES • Notification Appliance Circuits(two): • Patented addressable V-Plex polling • UL Listed wireless expansion - Programmable loop technology -Supports up to 250 wireless - Individually silenceable -Class B, Style 3 SLC zones/points • False alarm reduction features: - Supports 242 two-wire addressable - Supervised by control for check-in points signals - Exit error logic - Global polling technology for faster -Tamper protection for transmitters - Exit delay reset processing - Individually assignable to one of eight -Cross zoning - Supervised by panel partitions -Call waiting defeat -Zones individually assignable to - Supports commercial wireless smoke - Recent close report partitions and notification circuit(bell) detectors • Supports commercial hardwired, output or auxiliary relay • Up to eight doors using VISTAKEY®V-Plex addressable V-Plex®polling loop and - 4,000 ft. capability without the use of Access Control wireless zones shielded cable • Event reporting • Hardwired zones - Extender/Isolation bus modules • Local printer for event log printing - Provides eight style B hardwired zones - Eight zone-Class A and B expander •Communication - EOLR supervised for Fire and UL module burglary installations - Phone line, GSM and IP communicator - Eight zone-Class B expander module support - Supports N.O. or N.C. sensors - Single zone supervised contact module Panel operation during download - Individually assignable to any of - eight partitions(all fire zones on Single relay module for auxiliary - Four or 10-digit subscriber account fire functions numbers partition 1) -Supports anti-masking feature on - Up to 16 conventional two-wire smoke . Extra security feature that requires master "smart" motion detectors(e.g. code to allow installer into program mode detectors each on zone one and two DT7500SN) • (32 total) (enabled through Compass Downloader) Honeywell SPECIFICATIONS Electrical • Dual phone line capability using • CAN/ULC-S304-06-Signal Receiving • Primary power: 18VAC @ 72VA 5140DLM module Centre and Premise Burglar Alarm Honeywell No. 1451 AlarmNet®Communicators Control Units •Control panel quiescent current draw: • GSM, i-GSM and IP Communicators • UL1635-Digital Alarm Communicator 300mA System Units Cabinet Dimensions • Backup battery: • UL365-Police Station Connected • 18" Hx14.5"Wx4.3"D 12VDC, 12AH min to 34.4AH max Burglar Alarm Units and Systems - Environmental Lead acid battery(gel type) • UL609-Local Burglar Alarm Units and - • Storage temp: 14° F to 158° F Systems •Alarm power: 12VDC, 1.7A max for (-10°C to 70°C) • UL985-Household Fire Warning each notification(bell)circuit output • Operating temp: 32°F to 122°F System Units Total 2.3A @ 12V (0° C to 50°C) • UL1023-Household Burglar Alarm •Aux.standbypwr: 12VDC, 1A max • Humidity: 85% RH System Units •Total power: 2.3A at 12VDC • EMI: Meets or exceeds the following • ULC-S545-02-Residential Fire • Standby time: 24 hours with 1A requirements: Warning System Control Units standby load using 34.4AH battery - FCC Part 15, Class B Device • ULC/ORD-C1023-74-Preliminary • Fusing: Battery input, aux. and - FCC Part 68 Standard for Household Burglar Alarm notification(bell)circuit outputs are System Units - protected using PTC circuit protectors. IEC EMC Directive AgencyListings • ULC-S303-M91 -Standard for Local All outputs are power limited. 9 Burglar Alarm Units and Systems •Optional 24-volt kit • UL864-Control Units and Accessories Communications for Fire Alarm Systems • Factory Mutual Dialer • ULC-S559-04-Equipment for Fire • California State Fire Marshal Signal Receiving Centers and Systems • Line seize: Double Pole • UL1076-Proprietary Burglar Alarm • Ringer equiv: 0.7B Units and Systems • Formats:ADEMCO Low Speed, • UL1610-Central Station Burglar Alarm ADEMCO 4+2 Express,ADEMCO High Units Speed,ADEMCO Contact ID, Sescoa and Radionics VISTA®-250FBPT COMMERCIAL PARTITIONED FIRE AND BURGLARY ALARM CONTROL PANEL COMPATIBLE DEVICES Auxiliary Devices •4193SN and 4193SNP Two-zone Access Control • 6160CR-2—Red Fire Keypad Expander Modules • VISTAKEY®V-Plex®(addressable) • 6160—Burglary Keypad V-Plex Extender/Isolation Modules Access Control •6280,Tuxedo Touch®,Tuxedo Touch •4297 Extender/Isolator Module • VISTAKEY-SK Starter Kit with Wi-Fi®Graphic Keypads—Burglary •VSI Isolator Module • VISTAKEY-EX Expansion Kit • 4204—Relay Module,four Form C V-Plex Smoke Detectors •Integrates with WIN-PAK®and contacts •5193SD Pro-Watch®systems • 4204CF—Two supervised NAC circuits •5193SDT Alarm Communications • 5881 ENHC Series RF receivers V-Plex Passive Infrared Detectors U.S. • 5883H RF receiver •IS2500SN •GSMV4G—Digital Cellular • 6220S—System printer •DT7500SN Communicator with Two-way Voice Two-wire Conventional V-Plex(Addressable)Contacts Transport Capability Smoke Detectors •49395N-WH •iGSMV4G—Internet and Digital Cellular • System Sensor •4959SN Communicator • ESL V-Plex Glassbreak Detectors •iGSMCFP4G—Commercial Fire Digital • DSC • FG1625SN Cellular Communicator with Internet Horn/Strobes Seismic Detectors •iGSMHS4G—High Security Internet and • System Sensor •SC100 Digital Cellular Communicator • Wheelock •SC105 •78451-ENT—Internet/Intranet Enterprise • Gentex Commercial Wireless Devices Communicator Manual Pull Stations • 5808W3—Photoelectric Smoke/Heat Canada •5140MPS-1 Detector •GSMV4GCN—Digital Cellular •5140MPS-2 • 5806W3—Photoelectric Smoke Communicator with Two-way Voice V-Plex®(Addressable) Devices Detector Transport Capability •4208U Universal Eight-zone Ex Expansion •iGSMVCN4G—Internet and Digital p 5809—Wireless Heat Detector Module • 5817CB—Wireless Commercial Cellular Communicator •4208SN Eight-zone Expansion Module Transmitter •iGSMCFPCN4G—Commercial Fire •4101SN Single Relay/Zone Module Digital Cellular Communicator with g y 5869—Hold-Up Transmitter •4208SNF Class NB Expander Module •580000—Carbon Monoxide Detector Internet •4190SN Remote Point Module— •5800PIR-COM—Commercial PIR •iGSMHSCN4G—High Security Internet two zones and Digital Cellular Communicator Product specifications subject to change. ORDERING V250FBPT Commercial Fire and Partitioned Burglary Alarm Control Panel 12V Model V250FBPT24KT Commercial Fire and Partitioned Burglary Alarm Control Panel with External 24V Power Supply (6A, four outputs, synchronized) For more information:www.honeywell.com/security Automation and Control Solutions Honeywell Security Products Americas 2 Corporate Center Dr. Suite 100 Honeywell P.O. Box 9040 Melville, NY 11747 1.800.467.5875 WS250FBPTD/D November 2012 www.honeywell.com - ©2012 Honeywell International Inc. Honeywell 5193 Series V-PLEX® ADDRESSABLE SMOKE DEI ECTOR IP o ® Honeywell's V-flex Addressable Photoelectric Smoke Detectors are designed to provide open area protection and to be used with compatible UL or ULC-listed Honeywell control panels that support V-flex technology.The detectors incorporate a state-of-the-art optical sensing chamber and an advanced microprocessor. Built-in Drift Compensation algorithms automatically maintain proper operation at factory calibrated detection levels, even when sensitivity is altered due to the presence of contaminates settling into the unit's chamber.The 5193SDT/A also features a restorable, built-in, fixed temperature(135°F/57.2°C)thermal detector. FEATURES • Easy Installation: Installation is simplified by the use of •Versatile Mounting: Mounting is made simple with the a mounting base that may be pre-wired to the system, included hardware and the large mounting ports,which allowing the detector to be easily installed or removed for accommodate drywall anchors for easy surface mounting. maintenance or service. (See Figure 1). (See Figure 1). • LED Status Indicators:Two LEDs(green and red)provide •Tamper Protection and Tamper Resistance:The detector local visual indication of the detector's status—including contains a built-in tamper switch that can communicate normal operation, alarm,out of sensitivity and trouble back to the control panel in the event the detector is conditions. removed from its base. For an added level of security, •Test button:This button allows the user to perform periodic the detector also includes a tamper resistant element that testing of the detector's circuitry and verify that the detector prevents removal from the base without the use of tools. is within the sensitivity limits. (See Figure 1). DIRECT MOUNT HOLES U ( i:4c� kPrOir r' SNAP OFF TAB FOR TAMPER LOCK ` TAMPER RELEASE TAB Figure 1:Tamper-Resistant Feature/Wiring 5193 Series V-PLEX® ADDRESSABLE SMOKE DETECTOR SPECIFICATIONS • Heat Sensor: (Model 5193SDT/A): • Diameter(including base):5.3 inches(13.46 cm) 135°F(57.2°C); • Height(including base): 2.0 inches(5.08 cm) Fixed Temperature Electronic Thermistors •Weight: 6.3 oz. (178.6 g) • Operating Ambient Temperature Range: 32°to 100°F(0°to 38°C) •Agency Listing: UL 268; CAN/ULC S531 • Operating Humidity Range: • System Voltage Range: 7-14V 0 to 95% RH non-condensing • Standby Current(maximum @ 12V) •Storage Temperature Range: LED off: 1.2mA -4°to 158°F(-20°to 70°C) LED on: 2.8mA ACCESSORY(sold separately) To measure the detector's sensitivity, the SENS-RDR Infrared Sensitivity Reader tool (sold separately)should be used. It reduces testing time, simplifies sensitivity measurements and displays them precisely in terms of percent per foot obscuration. The SENS-RDR eliminates the need for magnets,voltmeters and ladders. 1 '1 r1 OR `.11•11111111V 4047=11-rx 1W=If Figure 2:Position of Reader ORDERING 5193SD Addressable Photoelectric Smoke Detector 5193SDT Addressable Photoelectric Smoke Detector with Integral Heat Sensor 5193SDTA Addressable Photoelectric Smoke Detector with Integral Heat Sensor(Canada Only) Accessory sold separately: SENS-RDR Handheld Sensitivity Reader Automation and Control Solutions Honeywell Security Products Americas 2 Corporate Center Dr. Suite 100 H®neyweII P.O. Box 9040 G Melville, NY 11747 1.800.467.5875 u51 essorio June 2015 www.honeywell.com ©2015 Honeywell International Inc. • Honeywell I Fire Alarm Communicators THE POWER OF CONNECTED IPGSM-4G Single or Dual Path Commercial Fire Communicator General The IPGSM-4G is a commercial fire alarm communicator that offers contact ID reporting with any Fire Alarm Control Panel(FACP)that has a built-in dialdr.This single or dual path communicator connects directly to the primary and secondary communication ports of a fire panel's DigitalAtarm Communicator Transmitter (DACT).It offers three selectable reporting paths which include:Cellular only,IP only, or IP primary/cellular backup.All signals from the IPGSM-4G are delivered to Honeywell's AlarmNet®Network Control Center,which routes highly encrypted WGSMJG Commercial Fre Communicator Ethernet data packets via a customer provided Internet connection or cellular network .0.a01110va1 to the appropriate central station.The state of the artAlarmNet network control center an is fully redundant and monitored 24/7.AlarmNet has the ability to route messages using AlarmNet-I and 800 PLUS services,providing true redundancy and multi-path Honeywell message delivery. Alternative communication methods are critical in the marketplace due to VoIP(Voice over IP),migration from POTS(Plain Old Telephone Service)and growth of digital radio networks.The IPGSM-4G's single path communications solution allows one technology to be used(either IP or cellular)to provide the appropriate connectivity to a central station.For added reliability,our exclusive dual path solution allows both technologies(IP and cellular)to be used together for maximum survivability or for local jurisdiction requirements that specify a dual technology system. FBA IURES & BENEFITS • Saves the cost of two • Operates over the • Works over any type of Private Static IP • QOS:Quality of Service dedicated phone lines. following customer provided addressing. diagnostics via communication Ethernet 10/100 based AlarmNet conveys vital • Single or dual path protocols:HSPA+(4G) network connection •Built-In Power Supply communicator communications-(can HSPA(HSDPA& (LAN or WAN),DSL module:On board information including communicate to HSUPA)(3G),EDGE modem or cable charging circuit design when message was central station using (2G GPRS)(2G). modem. accommodates back- received,signal cellular technology, up battery.Includes strength,and message internet,or both. • Selectable reporting • Data transmits over primary power and path used. paths and supervision standard contact-ID battery supervision. • Requires no change to intervals to meet NFPA protocol but is secured • 7720P Hand-held the existing Fire Alarm 72,chapter 26 with the industry's • Diagnostic LEDs: programmer for easy Control Panel requirements. advanced encryption Signal strength and setup. configuration. (Compliant with NFPA standard(AES 256 bit). status indicators. (Connects directly to 72 2010 and 2013 the primary and supervision • Supports both dynamic • Reliable connection:IP secondary telephone requirements.) (DHCP)or Public and and GSM connection ports of a DACT.) tested every day. The IPGSM-4G is designed to operate over the most • Primary City ID(two digits)obtained from your common cellular networks,including 3G and HSPA+. monitoring station. Its multi GSM platform technology automatically • PrimaryCentralStation ID(two digits)obtained from chooses the best available cellular signal in the area your monitoring station. based on signal strength and seamlessly self-adjusts to maintain critical life safety communication.In • Primary Subscriber ID(four digits)obtained from addition,it connects to any type of customer provided your monitoring station. Ethernet 10/100 base network connection(LAN or • Communication Module's MAC ID,and MAC CRC WAN),DSL model or cable modem.Our selectable number located on outside of box,and inside of the reporting path feature allows the radio to be module. configured for a single or dual path solution as well as All of these parameters are assigned bythe monitoring the appropriate supervision intervals based on NFPA station. 72 requirements.(See diagram below for selectable paths and supervision timing intervals.) Note:Someassembly isrequired.See Installationand Setup Guide #800-12454 for full details. aufv,i 7.4.n. utitactipsivi”;Mt, TimesFire Communicator Capability ,« 2010 GSM Single Path(cellular only) 5 minutes The IPGSM-4G is compatible with fire panels that use 2010 IP Single Path(IP only) 5 minutes the Contact ID communications format as described in 2010IP&GSM Dual Path(IP and cellular) 24 hours the SIA DC 05 standard. 2013 GSM Single Path(cellular only) 1 hour Alarm Net 2013 IP Single Path(IP only) 1 hour Honeywell's AlarmNet has been the nationwide leader 2013 IP&GSM Dual Path(IP and cellular) 6 hours in alarm communications technology since 1986.A reliable alternative for the transmission of alarm Operation signals,our radio network provides extensive coverage When an event occurs,the Fire Alarm Control Panel in the United States and Canada.AlarmNet Network goes Control center processes signals from powerful servers Dialer Capture Module detects the off-hook condition in multiple locations equipped with 24/7 and provides the fire panel with a dial tone.When the infrastructure support.The AlarmNet network consist fire panel detects the dial tone,it begins dialing the of redundant hardware servers,hot back-up databases central station.After the dialing is completed,the and generators with battery back-up at all locations to Dialer Capture Module returns a handshake to the fire ensure continuity of service.Signals from Alarm-Net panel.The fire panel then sends the contact ID reports are transmitted to the central station's receivers using to the Dialer Capture Module,which in turn sends a multiple communications paths consisting of the kiss-off after the report is successfully received from Internet,radio network or toll-free POTS service. the fire panel.The Dialer Capture Module sends the contact ID reports to the IPGSM communications Installation Requirements module.When all the reports are sent,the fire panel UL COMPLIANCE goes on-hook.The IPGSM communications module To meet UL864/NFPA,ensure the following: then transmits the messages to the central station either over the GSM network or the Internet • IPGSM-4G must be installed in accordance with (dependent on configuration). NFPA(National Fire Protection Association) standards 70 and 72. Easy to Program The IPGSM-4G communicator can be pre • The 4G must be mounted in the same room and programmed using the 7720P programmer to enter all within 20 feet of the fire panel. central-station information.This is saved to the • IPGSM-4G,and all equipment used for the IP IPGSM 4G communicator panel memory.When the connection(such as the router,hub,modem,etc.) IPGSM-4G communicator is installed at the site and shall be listed,must be powered from an un- connected to the Internet/Intranet,it registers itself with the AlarmNet receiver. switched branch circuit,and be provided with appropriate standby power. For most installations,the only required parameters • IPGSM-4G must use the 7AH battery(not supplied) are: to provide 24-hour backup capability. 2 IPGSM-4G Technical Specifications ELECTRICAL PRODUCT LINE INFORMATION Ademco'and AlarmNet'are registered trademarks of Transformer: I PGSM-4G: Internet and Digital Cellular Fire Alarm Honeywell International Inc. Primary: 120VAC,60Hz,0.5A Communicator Panel.Includes red cabinet with Ademco® Secondary: 18VDC,5OVA key and lock,wall outlet box,Dialer Capture Module,IGSM This document is not intended Communications Module,antenna&mounting adapter, to be used for installation Battery: purposes.We try to keep our One 12 V 7.0 AH lead-acid battery:(not supplied) productinformation Ppower supply,LED display board,ostl transformer,manual,&required screws,cables,etc. up-to- date and accurate.We cannot Battery charging current: 1 Amp maximum Antenna External Hardware cover all specific applications Battery discharge current: Standby 230mA,Active GSM-ANT3DB: 3db gain external/remote antenna or anticipate all requirements. 950mA WA7626-CA: SNA to N Adapter Allspecifications are subjectto change without notice. CABINET SPECIFICATIONS 7626-50HC: 50 ft.antenna cable,low loss Dimensions: 14.875"H x 12.75"W x 3.0"D(37.8 cm H 7626-25HC: 25 ft.antenna cable,low loss x 32.4 cm W x 7.6 cm D) Note:The GSM-ANT3DB and the WA7626-CA are both required for Color: Red installing an external antenna along with the necessary cable needed (7626-50HC:50 ft.or 7626-25HC:25 ft.) SHIPPING SPECIFICATIONS Weight: 5.3 lbs.(6.94 kg) Other Accessories Dimensions: 15.625"H x 13.79"W x 9.25"D(39.7 cm H 7720P: IPGSM-4G hand held programmer. x 34.9 cm W x 23.9 cm 0) HPTCOVER: Plug-in transformer box for IPGSM communicator. TEMPERATURE AND HUMIDITY RANGES BAT-1270: Battery 12 Volts,7 AH,sealed. This system meets NFPA requirements for operation at 0- AGENCY LISTINGS AND APPROVALS 49°C/32-120°F and at a relative humidity 93%±20/0 RH (non condensing at 32°C±2°C(90°F±3°F).However,the The listings and approvals below apply to the basic useful life of the system's standby batteries and the IPGSM-4G communicator panel.In some cases,certain electronic components may be adversely affected by modules may not be listed by certain approval agencies, extreme temperature ranges and humidity.Therefore,it is or listing may be in process. recommended that this system and its peripherals be Consult factory for latest listing status. installed in an environment with a normal room UL Listed: S789 temperature of 15-27°C/60-80°F. CSFM:7300-1645:0199 FDNY:COA#6219 For more information Learn more about Honeywell's IPGSM-4G and other products available by visiting www.honeywellpower.com. Honeywell Power Products 12 Clintonville Road Northford,CT 06472-1610 877.HPP.POWR DH-60769 I F 06/17 Honeywell www.honeywell.com 52017 Hone ywelf International Inc. THE POWER OF CONNECTED