Loading...
Plans (82) ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID-INTERTIED VIA A UL-LISTED REt AC ALTERNATING CURRENT POWER-CONDITIONING INVERTER. VALt®tTY OF PERMIT BLDG BUILDING 2. A NATIONALLY - RECOGNIZED TESTING LIAB CONC CONCRETE LABORATORY SHALL LIST ALL EQUIPMENT IN Th City of Tigard and IIS THE ISSUANCE OF A PERMIT 3 . DC DIRECT CURRENT COMPLIANCE WITH ART. 110.3. BASED ON CONSTRUCTION EGC EQUIPMENT N GROUNDING CONDUCTOR 3. WHERE ALL TERMINALS OF THE DISCONNECTING mp{U�Jee3 shall not be DOCUMENTS AND OTHER FEB 21 X019 (E) EXISTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, r�spa ible for discrepancies DATA SHALL NOT PREVENT !`) EMT ELECTRICAL METALLIC TUBING A SIGN WILL BE PROVIDED WARNING OF THE may 1 j ^' `� FSB FIRE SET-BACK HAZARDS PER ART. 690.17. V1/jllt;ilpear fl0reirl® THE CODE OFFICIAL FROM I °1T`s ��sg-> GALV GALVANIZED 4. EACH UNGROUNDED CONDUCTOR OF THE REQUIRING THE CORRECTION GEC GROUNDING ELECTRODE CONDUCTOR MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY OF ERRORS. QRSC 105.4 GND GROUND PHASE AND SYSTEM PER ART. 210.5. HDG HOT DIPPED GALVANIZED 5. CIRCUITS OVER 250V. TO GROUND SHALL COMPLY I CURRENT WITH ART. 250.97, 250.92(6). Imp CURRENT AT MAX POWER 6. DC CONDUCTORS EITHER DO NOT ENTER BUILDING Ise SHORT CIRCUIT CURRENT OR ARE RUN IN METALLIC RACEWAYS OR OFFICE COPY kVA KILOVOLT AMPERE ENCLOSURES TO THE FIRST ACCESSIBLE DC kW KILOWATT DISCONNECTING MEANS PER ART. 690.31(E). LBW LOAD BEARING WALL 7. ALL WIRES SHALL BE PROVIDED WITH STRAIN MIN MINIMUM RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY C� ®�TIGAR� (N) NEW UL LISTING. NEUT NEUTRAL 8. MODULE FRAMES SHALL BE GROUNDED AT THE UL REVIEWED FOR DE COMPLIANCE NTS NOT TO SCALE - LISTED LOCATION PROVIDED BY THE Approved: [ OC ON CENTER MANUFACTURER USING UL LISTED GROUNDING OTC: PL PROPERTY LINE HARDWARE. P01 POINT OF INTERCONNECTION 9. MODULE FRAMES, RAIL, AND POSTS SHALL BE Permit#• I/�,�j'� 0�� 'BOOS' PV PHOTOVOLTAIC BONDED WITH EQUIPMENT GROUND CONDUCTORS. SCH SCHEDULE Address: •t 2O 5j SV !T-,r S SS STAINLESS STEEL Suite #: STC STANDARD TESTING CONDITIONS gppraved plans TYP TYPICAL MA, �L, OC1 EQp srte By: Date: UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT , Sheet 1 COVER SHEET Sheet 2 SITE PLAN Sheet 3 STRUCTURAL VIEWS , Sheet 4 UPLIFT CALCULATIONS LICENSE GENERAL L NOTES Sheet 5 THREE LINE DIAGRAM R/-� Sheet 6:1 ELECTRICAL CALCULATIONS °A,°:;1: OR # 180498 1. ALL WORK TO BE DONE TO THE 2014 OSSC Cutsheets Attached RGC, CGC1 AND 2012 IBC. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE CURRENT NATIONAL ELECTRIC CODE AS AMENDED BY THE OREGON ELECTRICAL SPECIALTY CODE. MODULE GROUNDING METHOD: ZEP SOLAR t u AHJ: Tigard REV BY DATE COMMENTS g , �_®®1/19® Added 2 mods/Changed layout knota Portland General Electric °©®® UTILITY: t } g@ gq .,( 0 n �, � � � [C V��,4`n ®®® J 3-9724436 0 0 CUSTOMER: DESCRIPTION: DESIGN: • CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: Israel Perez Rosas CONTAINED SHALL NOT BE USED FOR THE RONALD PRAGUE 13.23 KW PV ARRAY T S L 1"1 BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook 12055 SW ANN ST 27 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUTSIDE THE RECIPIENTS MODDLEs:ORGANIZATI C A R D O R 9 7 22 3 THE SALE AND AND USEON, EPT OF INCONNECTION RESPECTIVE�m (42) Hanwha Q-Cells # Q.Peak DUO BLK-G5/SC315 TESLA EQUIPMENT, WITHOUT THE WRITTEN MVERIER: PAGE NAME: SHEET: REV DATE: PERMISSION OF TESLA INC. SOLAREDGE ; SE11400H-US000SNU2 COVER SHEET 1 a 1/19/2019 TOTAL ARRAY AREA (SF): 777 iir { ` PITCH: 22 ARRAY PITCH:22 TOTAL ROOF AREA (SF): 3118 t j ;' MP1 AZIMUTH: 186 ARRAY AZIMUTH: 186 t f ;� MATERIAL: Low Profile W-Tile STORY: 1 Story TOTAL ARRAY AREA IS RI 24.93 PITCH: 22 ARRAY PITCH:22 PERCENT OF TOTAL ROOF AREA / s MP2 AZIMUTH:276 ARRAY AZIMUTH:276 / MATERIAL: Low Profile W-Tile STORY: 1 Story PITCH: 22 ARRAY PITCH:22 , <, - MP3 AZIMUTH:96 ARRAY AZIMUTH:96 ©� MATERIAL: Low Profile W-Tile STORY: 1 Story 0 PRT ., GINF�`�`/ / Q w9082 � A ti ORE c MP1B L'-6" FSB ,,Q c l — — ihber''' V j ; ; SAS o 11/31/2019 Wi STRUCTURAL X11LEGEND I I41 I • Nicholas I Nicholas DigitallysiGorgndonedby, Y M P 1 C .Date.2019.01.31 MPJA I Gordon 16, x3 0 (E) UTILITY METER & WARNING LABEL I I 4 ' , ® INVERTER W/ INTEGRATED DC DISCO � I I m � I 8c WARNING LABELS _ 414, 1 j RELAY-14efitrip AUTOMATIC RELAY o,�� 1 �� DC DISCONNECT & WARNING LABELS STRUCTUR m STRUCTURE = 41110 CHANGE CHANGE U' roo I M �� AC DISCONNECT & WARNING LABELS — /\ CHANGE I r=nii/Ir — 0 5�z s r i(,Dill Lcit ' O DC JUNCTION/COMBINER BOX & LABELS N I r AC- +,-. RELAY , t ® ENERGY STORAGE SYSTEM FOR STAND I ,icb r-=-i CESS; H ALONE OPERATION ... A-C +^,l ,..., CD DISTRIBUTION PANEL & LABELS 1 ,r_ , 'ESS, CI LL=JJ_"_ *OA LG LOAD CENTER & WARNING LABELS 3' FSB • Front Of House 3 FSB �i�/NASB I i O DEDICATED PV SYSTEM METER PPIZA*411 , 41A1 l'y 411) RAPID SHUTDOWN •11t ire 0.41111k STANDOFF LOCATIONS 4 0 iii lb, CONDUIT RUN ON EXTERIOR CONDUIT RUN ON INTERIOR I i GATE /FENCE ,i A‘ A, -0.*-44ft\ 0 4 HEAT PRODUCING VENTS ARE RED 1t 'i INTERIOR EQUIPMENT IS DASHED ,, /.....04,01 ,11 1--- .....)"4,0 •..,2,,,,--r - 'l i .ir (E)DRIVEWAY i i joh,i,,h..w., , „ liVvolippt 410,101p** 0 40*** it pA SITE PLAN N 12055 SW Ann St Scale: 3/32" = 1' W `� E 414171)0,0011101111 / t _ 0 1' 10' 21' ���i%ice•//;�/%%�/io////%%moo/i s CUSTOMER: DESCRIPTION: DESIGN: CONFIDENTIAL- THE INFORMATION HERON JOB NUMBER: JB-9724436 00 Israel Perez Rosas ,111111111111, CONTAINED SHALL NOT BE USED FOR THE RONALD PRAGUE 13.23 KW PV ARRAY T = S L n BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: 12055 SW ANN ST 27 KWH ENERGY STORAGE SYSTEM SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: TIGARD, OR 97223 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (42) Hanwha Q-Cells # Q.Peak DUO BLK-G5/SC315 PAGE NAME: SHEET: REV: DATE: TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PERMISSION OF TESLA INC. SOLAREDGE # SE11400H-US000SNU2 SITE PLAN 2 a 1/19/2019 • ..‘ 908271'/ / Ari FAI IN r ' \ . tiORE c•4, 6,.._ IP, (N) PV MODULE ck'o �` LAS 1/31/2019 S'I'RUCI'[7IAL ONLY //0.11 (E) MOUNTING PLANE (MP) TYPICAL PV SIDE VIEW Age" SV . NTS INSTALLATION ORDER ZEP SPANNER BAR LOCATE RAFTER, MARK RAFTER (6) LOCATION, AND REMOVE TILE. (1) PLACE STANDOFF BASE & DRILL � -- -- --- - wi . ---- PILOT HOLES AT THE RAFTER ��� LOCATION." DIA BOLT & NUT 1! AIL �w� CLEAN PAPER AROUND PILOT �� (1) (2) Er l (7) (3) 2) HOLE. ZEP SPANNER '_________ mi...... �� MI: BAR CLAMP --7'r — 1l-„ mai �`� 3) ADJUST STANDOFF HEIGF. TO BATTEN STANDOFF ` i . SEAL PILOT HOLES AND BOTTOM (E) TILEWIPPIPIPP- 0 0 0 0 (4) OF STANDOFF WITH POLYURETHANE (E) ROOF DECKING (5)(5) (4) SEALANT. 5/16" DIA STAINLESS '\' 5) LAG STANDOFF INTO RAFTER. - STEEL LAG BOLT `� (2-1/2" EMBED, MIN) LOWEST MODULE SUBSEQUENT MODULES 0NOTCHTILE WEDST NDOFERRING TO FIT - (E) RAFTER 410) STANDOFF Scale: 1 1/2" = 1' ( REINSTALL TILE. CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: JB-9724436 O O CUSTOMER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE RONALD PRAGUE 13.23 KW PV ARRAY Israel Perez Rosas T Y. 5 L n BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook 12055 SW ANN ST 27 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUTSIDE THE RECIPIENT'SMODULES: THEANDCNECTION TIGARD OR 97223 SALE USEEE OF PT ITHE N ON CTIVE�TM (42) Hanwha Q-Cells # Q.Peak DUO BLK-G5/SC315 TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV: DATE: PERMISSION Mf TESLA INC. SOLAREDGE # SE11400H-USOOOSNU2 STRUCTURAL VIEWS 3 a 1/19/2019 sc$EQ PBOffx w CfiN� • J/ 9082 A Of • 7 "70 LAS G0 11/31/2019 STRUCTURAL ONLY 01.192019 Version#741 DESIGN SUMMARY Job5 9724436 Jobsite Speak.Ostign Coltenl ';3 Design Code ASCE 7-10 e Factor 1 1.0 Ultimate Wind Speed V Ult. 115 mph Fig.1009A 1,aj ob tse (."..S;i�E. F "S n"« € C 3 , 0 1 .ic . ‘ Section261€ Ground Snow Load pg 25 0 psf ASCE Table 7-1 Specific tiesl n Information I NIP Name MPIA MP1B MP1C 11P2 MP3 Roofing9partlah; _ t_of Spanish His Root Spanish Tide Roof Spanish Tile Roof Spanfii��000, = Standoff Mighty Hook MS ST Mighty hook iii ST Mighty Rook HUG sr Mighty hook NUG ST flighty Hoak HUG ST is P�tc 's` :i s 22' )2" 22" a..„ SLIRLL PV 25.0• 25.0 psf 25.0 psf 25.0 psf 25.0 psf SLIRff,J,.:, ' 'z r4 25.0 psf "2&0 f:< .4 5.0 psi st,f MP Name MP1AMP1B MP1C MP2 MP3 " -Spa. . clrtg ..a,t..a., �...... ..E31iinw 48" 480'.17.-77 4 �I•., CSA d J'...' X-Cantilever 17" 17" 17" 17" 17" Y-Cantilever 24' 24" 24" 24 24" .. ' Sp -' € , 48" 48" 4aolllr== X-Cantilever 17" 17" 17" 17' 17 f-Spacing" , 52" 52" ., 62" 52" E[n€t 62". ,rte Y-Cantilever 24" 24" 24" 24" 24" LaYoull Not-Staggered Not St gered Not-Staggered Not-Staggeree-- , -_,;717 X and Y are maximums that are always relative to the structure framing that supports the PY. X is across rafters and Y is along rafters. CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: JB-9724436 0 0 CUSTOMER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE RONALD PRAGUE 13.23 KW PV ARRAY Israel Perez RosasT L rl BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook 12055 SW ANN ST 27 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES TIGARD OR 97223 ORGANIZATION, EXCEPT IN CONNECTION WITH > THE SALE AND USE OF THE RESPECTIVE (42) Hanwha Q—Cells # Q.Peak DUO BLK-G5/SC315 TESLA EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE: PERMISSION OF TESLA INC. INVERTER: SOLAREDGE # SE11400H—USOOOSNU2 UPLIFT CALCULATIONS 4 a 1/19/2019 GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO TWO (N) GROUND Panel Number:NoMatch Inv 1: DC Ungrounded INV 1 -(1)SOLAREDGE SE11400H-USOOOSNU2 LABEL: -(42)Hanwha Q-Cells # Q.Peak DUO BLK-G5/SC315 OR # 180498 RODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:23789052 Inverter; 11400W,240V/208V,98%;HD Wave w/nifed Disco and ZB,AFCI PV Module; 315W,292.2PTC, 40MM, Black Frame, MC4, ZEP, 1000V RGC, CGC1 Overhead Service Entrance INV 2 Voc: 40.29 Vpmax: 33.46 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER �E 200A MAIN SERVICE PANEL SoI City E) 200A/2P MAIN CIRCUIT BREAKER (N) 125A BRYANT Inverter 1 (E) WIRING LOAD CENTER CUTLER-HAMMER W A 1 AUTOMATIC RELAY® Disconnect © SOLAREDGE - Dc+ D1 Z Y SE11400H-USOOOSNU2 DCC MP3,MP2: 1x14 ni- tA 200A/2P A 12 2P 60 2P n B L I • zaov I r v �-- -- -0 O J F 1. • C • -0 -0 • \• L2 •_ DC+ I DC+ rH:*--: - N -- 7-7--..----- Dc- I I q DC- MP 1: 1x14 GNDI EGCI '� DC+ ,,,c,_ .\, MP2,MP1: 1x14 - - 13-11 } 1 U i Tf-F -'--- 1 0 J--- CUTLER-HAMMER ,�-- - ` �j-�Ec - 1Ei �_ DC- DC- m m I I -� Disconnect ®i ____EGC___.k[L -- ■ _ EGC u J Lam, t___� V T EGG' N L2 L1 GEC I 302P W I 00 - �• 00 L1 (1)Conduit Kit; 3/4' EMT _L- �+ • �� L2 �( ENERGY -• • STORAGE o � ZV CD am,,,,,, ,L____i�____�I 7-_ li EGc SYSTEM SOLAREDGE 11400 INVERTER HAS 3 MPPTS -- ALLOWABLE 3 STRING MAX 200/ 2P I- 1 • w I I CUTLER-HAMMER TO 120/240V ~ Disconnect SINGLE PHASE -1• • I UTILITY SERVICE . • • (E) LOADS i I I 30/ 2P W �• 00 L1 - l • ENERGY I I i • ' \• I L2N x STORAGE --------- ----�GND _ �/ Ecc SYSTEM (E) 200A Main Service Panel POI (2)Grond Rod 5/8 x 8, Copper Voc* = MAX VOC AT MIN TEMP 7-(1)Tesla 1118431-00-K )( -(2)Tesla /2012170-03-B /f, A -(1)SolarCity#4J; 4 STRING JUNCTION BOXD BACK-UP GATEWAY; for ACPW2.0, ASY, NA with 3G w/Antenna, PW2.0, 10kA SCCRI ASSEMBLY, AC POWERWALL2, 5KW,13.5KWH,88P /y UNFUSED, GpROUNDED, Black -(1)Siemens Al EQ8695/MBK200A -(2)CUTLER-HAMMER CUTLER-HAMM #BR230 -(1)CUTLER-HAMMER �f BR2125 PV -(42)SOLAREDGE LXI P40-NM4 ZEP M Circuit Breaker MBK 200A/2P, 22kAIC Y Breaker; 30A/2P, 2 Spaces Breaker; 125A/2P, 2 Spaces \ (2)CUTLER-HAMMER DG221UR6 -(1)CUTLER-HAMMER 11 BR260 Vit I Disconnect; 30A, 24OVac, Non-Fusible, NEMA 3R Breaker; 60A 2P, 2 Spaces -(2)CUTLER-HAMMER11 DGO3ONB -(1)BRYANT 11 BR816L125RP Ground/Neutral it; 30A, General Duty(DC) Load Center, 125A, 120/240V, NEMA 3R B (1)CUTLER-HAMMER/DG222URB Disconnect; 60A, 24OVac, Non-Fusible, NEMA 3R -(1)CUTLER-HAMMER DG100NB - Ground/Neutral Kit; 60-100A General Duty(DG) ,.._ c*.. VDC Isc - ADC ......... THWN-2, .la. . _.. (1)AWG/1, Black I (1)AWG �T10, THWN-2, Black (1)AWG �6, THWN-2, Black Voc -500 VDC Isc =30 ADC (2)AWG x'10, PV Wire, BOON, Black Vo 500 15 O o (1)AWG #1, THWN-2, Red ®L F(1)AWG#10, THWN-2, Red ®1c61-(1)AWG#6, THWN-2, Red Vmp =350 VDC Imp=24.88 ADC O ca-(1)AWG#10, Solid Bare Copper EGC Vmp =350 VDC Imp=12.44 ADC O (1)AWG#I, THWN-2, White NEUTRAL-(1)Copduit 6666 (1)AWG Iy10, THWN-2, White NEUTRAL -(1)COJJDUIT KIT (1)AWG X10 1HHN/THWN-2, Green EGC.-(1)Conduit.Kit.3/4. EMT 1 x 10' EMT Conduit 2 PVC; Schedule 80 -(1)AWG #10, THWN-2, Green EGC (1)AWG#6, THWN-2, Black Voc* =500 VDC Isc =15 ADC (2)AWG $10, PV Wire, 600V, Black Voc =500 VDC Isc =15 ADC -(1)AWG #2, , THWN-2,Green EGC/GEC C)1:41-(1)AWG 2 (3)AWG /2/0, Black I (1)AWG#6, THWN-2, Black #6, THWN-2, Red Vmp =350 VDC Imp=12.44 ADC O � (1)AWG #10, Solid Bare Copper EGC Vmp 350 VDC Imp=12.44 ADC ® -(1)AWG!4,Stranded; 1, GREEN EGC/GEC ©M-(1)AWG#6, THWN-2, Red . . . . . . . .1)AWG#10,•THHN/1HWN-2,.Green. EGC.-(1)Conduit Kit;.3/4"EMT, . . . ) olid Bare V EGC Vmp =350 VDC Imp=12.44 ADC S5 666 . . . . . . . . . . . EL- Cu, tranded; 1 (1)AWG #10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=47.5 MC w (2)AWG X10, PV Wire, 600 Black Voc* 500 VDC Isc 15 ADC 1-(1)Copduit -(1)AWG#8, THWN-2, Green . . EGC/GEC-(1)Conduit Kit; 3/4'.EMT , . . . , O c(a-(1 AN#10, Solid Copper m m 2 PVC; Schedule 80 t- CUSTOMER: DESCRIPTION: ���� CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: JB-972.1-436 00 Israel Perez Rosas ® �"® CONTAINED SHALL NOT BE USED FOR THE RONALD PRAGUE 13.23 KW PV ARRAY �' S L �..� BENEFIT OF ANYONE EXCEPT TESLA INC.,N NOR MOUNTING SYSTEM: 12055 SW ANN ST 27 KWH ENERGY STORAGE SYSTEM SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH NODDLES: TIGARD, OR 97223 THE SALE AND USE OF THE RESPECTIVE (42) Hanwha Q-Cells # Q.Peak DUO BLK-G5/SC315 PAGE NAME: SHEET: REV: DATE: TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PERMISSION OF TESLA INC. SOLAREDGE # SE11400H-USOOOSNU2 THREE LINE DIAGRAM a 1/19/2019 P (.�;4 e@ Label Location: ' " Label Location: €€ Label Location: (C)(IC)(CB) MAXIMUM AC (AC) (P01) t ` (POI) Per Code: Per Code: • h ;, E Per Code: IFC 605.11.1.4 MilMAXIVOLTAGE NEC 690.54 ``'' NEC 690.64.8.7 ' , Label Location: . . ,",[1:1!..""7/,,,HL 1 , DEVICERR7-l:1,7,;:i:",'-:',1,',-Iii,',..',.- ' - .. . � . �' (DC) (INV) Per Code: ii7,111SCON •, ... NEC 690.14.C.2 ,_ Label Location: (AC) (POI) " € Per Code: Label Location: NEC 690.17(4) (DC) (INV) Label Location: ,� Per Code: w CDC) (INV) NEC 690.35(F) EPer Code: " idIlliJilli RTO BE USED WHEN NEC 690.53 '<< INVERTER IS p � UNGR• OUNDED - IT Label Location: (AC) SYSTEM is �rT F . E y, Label Location: (DC) (CB) Per Code: pENOT TOUCH, TF TERMI—AIS NEC 690.17(4) Label Location: MIN I ' AND i T OF (POI) LOA D SI17ES M t N Per Code: IPEN PIGSI 'N TDCHE OUt�L iRD DO3 ;3 K NEC 690.17.4; NEC 690.54 :ALWAYSP,. LS T SON SOLAR M LINEAE' D SIDE 33 EXPOSED ERGI�;, E OPEN POSITION,F8 ICE LJ - I7E B URGE MAIN B RC Label Location: MAXIMUM AN n © 1PEAT1NG C RRENT ARN (DC) (INV) MAXIMUM , Per Code: tbPAtINGV0LTAGE L ERIC SHOC 1G �UNIAULT IS= NEC 690.5(C) Ti N MAt Y OIOU N Au 0 -A OR.S MAY ND�13 AND ENE Label LocatooNDion: (RsizED POI) DUALNGROUSOU" Per Code: 5E RCE: NEC 690.64.B.4 Label Location: PHO[ tC"SYSr .� . (AC) (P01) ): A Disconnect Per Code: (C): Conduit (CB): Combiner Box NEC 690.14.C.2 (D): Distribution Panel Label Location: ' (DC): DC Disconnect ( (D) (POI) (IC): Interior Run Conduit Per Code: HD (INV): Inverter With Integrated DC Disconnect � NEC 690.64.13.4 (LC): Load Center (M): Utility Meter (POI): Point of Interconnection Label Set Label Location: "' Label Location: NTER SECOND �E� (BLC) � ,f (MP) Per Code: Per Code: #RCE" tc NEC 408.4 NEC 705.12.D.3 TiiiRDoORCEIS_ ERC, LLocation: f .,.." (BLC)abel �" Per Code: Label Location: NEC 220 (MP) Per Code: MULTIPLEIPIsil THI "` -t tL ' ENT FEDEF� NEC 705.12.D.2.3.c Label Location: f IN (RATIG ALL n E DEV OE, Per Code: N.CGUNAR1 Et NT NT sLVBL NEC 312.8(3) ''' LoCATION 0F DISCONNECT AT EPtEELRGY STORAGE RACKUF*LOAD PAN Label Location: � (MP) SOUscE DLIA is Per Code: SEooND SOURCE NEC 705.12.D.3 ENERGY STOR,4GE SYSTEM Label Location: (MP) 13=- Per Code: Label Location: CTE (MP) EON ADjACENT � Per Code: 11 Label Location: (MP) OPPOSITPer Code: Label Location: ON SITE (MP) �ENERGYSITO°CRAA�c� � Per Code: (AC): AC Disconnect (BLC): Backup Load Center (MP) :Main Panel Label Set `.iiSOlarCity ZepSoLar Next-Level PV Mounting Technology '',rSOlarCity ZepSolar Next-Level PV Mounting Technology • Components ZS SpanIII _ . for concrete tile roofs lx 3x 4x Spanner Bar zap GroomCam Poor • Part Nos. r1s 850-1400-4x 3y 580-1399-3x 850-1398-1 x Ground Zap 1 ` Span Bar T x - - il �: "manner Clamp .. ii ,'.::::?: NN „,, t Splice Kit Spanner Clamp �'1. , Part No.850-1401 Part No.850-1194 ;-471,,,,_,7,..., _. 1 , Listed to UL 2703 Listed to UL 2703 Corner Intent aMN Adjustabtlh tfnek �oMF4T,e�F Description • PV mounting solution for concrete tile roofs �F,® • Works with all Zep Compatible Modules 4 °omvps • Auto bonding UL-listed hardware creates structural and electrical bond , u • Zep System has a UL 1703 Class"A"Fire Rating when installed using modules from any manufacturer certified as"Type 1"or"Type 2" Mighty Hook V2, HDG Interlock Cam Foot CO LISTED Specifications Part No.850-1461 Part No.850-1388 Part No.850-1413 Listed to UL 2703 Listed to UL 2703 Listed to UL 2703 • Designed for pitch roofs Q • Installs in portrait and landscape orientations • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 • Wind tunnel report to ASCE 7-05 and 7-10 standards • Zep System grounding products are UL listed to UL 2703 and ETL listed to UL 467 • Zep System bonding products are UL listed to UL 2703 �" E4 • Engineered for spans up to 72"and cantilevers up to 24" • - • Zep wire management products listed to UL 1565 for wire positioning devices " • Attachment method UL listed to UL 2582 for Wind Driven Rain Ground Zep Array Skirt, Grip, End Caps DC Wire Clip • Part No.850-1172 Part Nos.850-0113,850-1421, Part No.850-1448 ETL listed to UL 467 850-1460,850-1467 Listed to UL 1565 zepsolar.com zepsolar.com Listed to UL 1565 This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for verifying the suitability of ZepSolars products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps.zspats.com. Document#800-1730-001 Rev A Date last exported:April 20,2015 2:14 PM Document#800-1730-001 RevA Date last exported:April 20,2015 2:14 PM =r n _. SolarEdge Power Optimizer - Zep CompatibleTm solar ` MsoIar - • I : r ' -- �' odule Add-On For North America Ft ZEP- ".,, ::. . ,t ' SolarEdge Power Optimizer - ; , ", P300ZEP{for60cellPVmodules) P400-ZEP{for 72&96 cell modules} p „,..,:,,,A,,,,,, ,..,,,„,1„,-,.. ;, , :_ £ INPUT f� TM - y ,s . .,, ^'-i'n5 R: ',-” Rated Input DC powerlu..-_...................._. _._._....._..._................................... 300 400 • W .... Ze Com atible Module Add-On . 3 £_; Es, p p 44 °"s Absolute Maximum Input Voltage(Voc at lowest 48 80 Vdc , ; .: 1: _ i •�", "' temperature) '`,:„-,,,,,,,,,,re x,',:, MPPT Operating Range 8-48 8-80 Vdc For North America P30 E ? P00-SEP ;� "` Maximump Short g g y r , �. �. ' . " ;N=t�j , - Maximum DC Input Cur Current ( ) 125 2063 Adc Current Isc { Maximum � ;.r;: �.' ;.v _b s.. ,„,,,,,,,,„,,e, ��'.-€":'.xr;.h< ??„s �, -��” Efficiency 99.5 I:" x. , 216, Weighted Efficiency 8. - • .", ", >� Overvoltage Category 9II r" �'': OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING INVERTER); f., x, Maximum Output Current 15 <''< ," --'' `i Adc " - .w": ,.-" r7 Maximum Output Voltage 60 Vdc "„ -1,•-?.-4511 ,i1 :; • OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) r, "",. --n , SafetyOutput Voltageper Power Optimizer 1 p B p Vdc , a,__ COMPLIANCE „lr� I. �: STANDARD u. . FCC t15 Class B,IEC61000-6-2,IEC61000-6-3 r€' •�°.>.�. _. EMC Par t15 '% Y. ;";, vX%; ,� _ P IEC62109-1(class II safety),UL1741 r, 'h4"""£ :' RoHS ........... . . . . . ...... .... =,; �' �� <L�, � Safety Yes s; ;.§ :: INSTALLATION SPECIFICATIONS W. �s ". £�: ':-;?;7:41,4,4. ., , � 1`- � ,, •. __. .. .. ...__...__ ... ..._.... ....... _ ..."._..__._ ,fr", ,Tr , , 4 g ;,y .. �t� s. '*,„,,`81::•=e:'-,:,,,,',-0. Maximum Allowed SystemVoltage1000 Vdc "�u ;y , '% Dimensions includingmountingbracket xLxH 128 x 196 x 27.5 5 x 7.71 x 1.08 128 x 196 x 35 5 x 7.71 x 1.37 mm j i s .,.:,, " ) / / mm/in s° f y" . 1 128x 152 x35/ I :.- % ... - .:. ; Dimensions excluding mounting bracket (WxLxH) 128 x 152 x 27.5/5 x 5.97 x 1.08 I / mm/in , -,' ,;,. ,' 5 5.97 x 1.37 x 1 Weight(including cables and mounting bracket) 720/1.6 840/1.9 kg/lb ( h ""':. "t"' ;, • Input Connector MC4 Compatible ! "<;-"Y _�Output Connector Double Insulated:MC4 Compatible "" ` Output Wire Length 0.95 3.0 1.2 3,9 m/ft the , 1; 4- .v...•" -, f`":. tom, y- , OperatingTemperatureR g -+85/-40- 'C/'F ' - Protection.I..;.; s Ii * Humidity 5 '.: Relative 680/NEOMA % " �• ��£ " ane -40 +185 , #.s � -1 ':5i;, ;;q,h "" �:^;'"!"i'" tzi Rated STC power of the module.Module of up to+5%power tolerance allowed �Mv • �' '. .`"='5 USING A SINGLE PHASE THREE PHASE THREE PHASE •�. �, .�,•• "� PV SYSTEM DESIGN `,i-.;",.;,, f l.," SOLAREDGE INVERTERIZJ... —....... ..- ND WAVE PHA 208V 480V SINGLE SE Minimum String Length(Power Optimizers) ' 8 10 I 18 ,, , ::.• ,y» Maximum String Length(Power Optimizers) 25 25 50 :.t: -.Compatible with Zep Groove framed modules ` . 5700(6000 with Certified Zep Compatible"bracket �: - Mitigates all types of module mismatch iassesL tOtt1 Maximum Power per String 5250 6000 12750 W SE7600H-US) Attaches to module frame without screws- t ,fln coof manufacturing toleritifeto partial shading ' Parallel Strings of Different Lengths or s Yes r and mountingcosts ,r Flexible system desigrtit5r airourn� .ttilizaton r Orientations rientations f detailed string sizing informafion refer to:http://www.solaredge.com/sites/default/files/stnng_s:zing_na.pdf. tier optimizer equipment grounded through the bracket — Next generation maintenance-WA module-level monitoring - - Up:to 25%more energy -, Module-levetvottage shutdown frx'4nstaller and firefighter Superior efficiency{99.59x) Y : .: , USA-CANADA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-UK-ISRAEL-TURKEY-HUNGARY-BELGIUM-ROMANIA-BULGARIA www.solaredge.us �,.'SYz"" ,'"-=':`:5', '-',y�;, "" "..� „ "=^�•- �.` =:: '" 1x4 ig resfi[By trtc A11, gins ratoi v C ,f'a, O Stgo ' 1Sv per; " - `L'"L arN-tr{ ifnfsrSH Or .Bss€eeafl trac �ks.nt S.rjfaf.,`- note3et;IStc AR o 48'"' stent' harem�a,� dtRrntrsQetrrdrt55GBw@rtjesnecw .raaw,tzvzAi7:,V.Y;;SUDisctta� ce. �' ;%` 1 -' POWERWALL P OW ERWA.LL Backup Gateway ill- Tesla Powerwall is a fully-integrated AC battery system for __, , 1,„„-Aw. _ .., The Backup Gateway for Tesla Powerwall provides energy management residential or light commercial use.Its rechargeable lithium-iont and monitoring for solar self-consumption,time-based control,and battery pack provides energy storage for solar self-consumption, r backup. time-based control,and backup. 1` -- The Backup Gateway controls connection to the grid,automatically r,4`' detecting outages and providing a seamless transition to backup Powerwall's electrical interface provides a simple connection to power.When equipped with a circuit breaker,the Backup Gateway can any home or building.Its revolutionary compact design achieves be installed at the service entrance, market-leading energy density and is easy to install,enabling owners to quickly realize the benefits of reliable,clean power. The Backup Gateway communicates directly with Powerwall,allowing you to monitor energy use and manage backup energy reserves from any mobile device with the Tesla app. PERFORMANCE SPECIFICATIONS MECHANICAL SPECIFICATIONS PERFORMANCE SPECIFICATIONS MECHANICAL SPECIFICATIONS AC Voltage(Nominal) 120/240 V Dimensions 1150 mm x 755 mm x 155 mm AC Voltage(Nominal) 230 V,120/240 V Dimensions 740 mm x 378 mm x 129 mm (45.3 in x 29.7 in x 6.1 in) (29.1 in x 14.9 in x 5.1 in) Feed-In Type Split Phase Feed-In Type S ogle&Split Phase Weight 125 kg(276 lbs) Weight 16.4 kg(36 lbs) Grid Frequency 60 Hz Grid Frequency 50 and 60 Hz Mounting options Floor or wall mount Mounting options Wall mount Total Energy' 14 kWh Disconnect Current 200 A Usable Energy' 13.5 kWh 755 mm 155 mm Maximum Input Short Circuit Current 10 kA 378 mm 129 mm (29.7 in) (6.1 in) (14.9 in) (5.1 in _)I Real Power,max continuous' 5 kW(charge and discharge) k• 1— Overcurrent Protection Device' 100-200 A;Service Entrance RatedF H `I Real Power,peak(10s,off-grid/backup)' 7 kW(charge and discharge) Overvoltage Category Category IV t ■ ■ r Apparent Power,max continuous 5.8 kVA(charge and discharge) AC Meter Revenue grade(+/-1%) T ® 5 L Fa Apparent Power,peak(10s,off-grid/backup) 7.2 kVA(charge and discharge) Connectivity Ethernet,Cellular(3G)°,Wi-Fi I Maximum Supply Fault Current 10 kA User Interface Tesla App l Maximum Output Fault Current 32 A 1150 mm Operating Modes Support for solar self-consumption, (45.3 in) time-based control,and backup Overcurrent Protection Device 30 A 740 mm Backup Operation Automatic disconnect for seamless (29.1 in) Imbalance for Split-Phase Loads 100% backup transition Power Factor Output Range +/-1.0 adjustable c Modularity Supports up to 10 AC-coupled Power Factor Range(full-rated power) +/-0 85Powerwalls ----- ----- ------- ----- __.. _------ ......_.-__ r —r II Internal Battery DC Voltage 50 V Warranty 10 years Round Trip Efficiency'•' 90% 'Circuit breaker required for installation at service entrance. Cellular connectivity subject to network operator service coverage and signal strength. Warranty 10 years ENVIRONMENTAL SPECIFICATIONS 'Values provided for 25°C(77°Fl,3.3 kW charge/discharge power. Operating Temperature -20°C to 50°C(-4°F to 122°F) 'In Backup mode,grid charge power is limited to 1.67 kW. 'AC to battery to AC,at beginning of life. Optimum Temperature 0°C to 30°C(32°F to 86°F) COMPLIANCE INFORMATION ENVIRONMENTAL SPECIFICATIONS Operating Humidity(RH) Up to 100%,condensing Certifications UL 1642,UL 1741,IEC 62109-1, Operating Temperature -20°C to 50°C(-4°F to 122°F) 1 COMPLIANCE INFORMATION -_ Storage Conditions -20°C to 30°C(-4°F to 86°F) CSA C22.2.107.1Operating Humidity(RH) Up to 100%,condensing Certifications UL 1642,UL 1741,UL 1973, Up to 95%RH,non-condensing Grid Connection Worldwide Compatibility 1--- State of Energy(SoE):25%initial Maximum Elevation 3000 m(9843 ft) UL 9540,IEEE 1547,UN 38.3 Emissions EGG Part lb Class B,ICES 003, Grid Connection Worldwide Compatibility Maximum Elevation 3000 m(9843 ft) IEC 61000-6-3,EN 55024, Environment Indoor and outcoor rated EN 301489-1,EN 301489-7, Emissions FCC Part 15 Class B,ICES 003 Environment Indoor and outdoor rated Enclosure Type NEMA 3R EN 301489-17 — Environmental RoHS Directive 2011/65/EU Enclosure Type NEMA 3R Ingress Rating Environmental RoHS Directive 2011/65/EU, Seismic AC156,IEEE 693-2005(high) Ingress Rating IP67(Battery&Power Electronics) WEEE Directive 2012/19/EU, IP56(Wiring Compartment) Battery Directive 2006/66/EC • Wet Location Rating Yes REACH Regulation Seismic AC156,IEEE 693-2005(high) Noise Level @ lm <40 dBA at 30°C(86°F) T®5 L^ TESLA.COM/ENERGY T E S L n TLSLA.COM/ENERGY 4-,-- "-'44--4;TY,-'--'.,,i" ';If:- f- t:,,,-.:,,--:-Tr ----'":. ,- '-'4,10:-q ' ' -,-,,--;,-.-,.. -:',-,-. -:-.-. . . „ , ," , , ,, ,.- , , 4 44, awlill i+; : me "--40"!";.'::j1,:ir;: -: :!!''' "- : -';:t iii,',..rt'7.:Illi.; --' solar, .--. 1 . t; .• erica Arr.1 wo,.. : , T::,,:fl;',--V.0; -;--- --: ,,,,ir-'llC--":4,,- '' iiik4 Single Phase Inverters for North Am So ark- 4 ' ' -5 4-1, $ '"`,,,,. A.:----7 ,3,-":-33.3%,,,,,;!" :; -3 — 3z," 3 - ', 4-4--' 3%r5;i..7.7333-43-- , %.1,,, ,,;-,""33,,,;';-,' ,:, SE3000H-US/SE3800H-US/SE5000H-US/SE6000H-US/SE7600H-US/ SE10000H-US/SE11400H US - .4 - --- - :.:,-,,,"-:44,,,,-, ,, -.-- ,,,„::."1 .74'-::-:' '';: IW*74.-t!-_. ------ - •- '''' :: !!- ."t"..l,' ':::"--- '-'1 - -7±:';.:ge: .,--'' .. ... OUTPUT i SE3000H-US SE3800H-US lr SE5000H-US 1 SE6000H-US i SE7600H-US 5E100 70H1 5E11.40_7-US 3800 @240V 11400 VA ' SolarEdge Single Phase Inverters .„„ — Rated AC Power Output ' 3000 6000 7600 10000 ' 44.: -f,,,Z : ,T ,, ,, 7,rq,15-,,, -f'3,333,ii","33, „ ,.%,-..-?:0-, 6000 7600 10000 11400 VA ''''-1:?.'1:, '1i4,;''-'4,' ':-'',!'' ''';-',-FL'''. -;:..'"';.-P;i: ' Max.AC Power Output 3000 33830000 3800@240V Max !I 5000 3300 p208V 1 for North America 5000 - Vac '--,-*:, - -. .4 AU 7. 4.4! ,; -': AC Output Voltage Mm Nom i / - 'I; ",„: ,i4,4'.:Y 1.-:-',,rf-j33'13;4043, il! " -3:;- - Max.(183-208-229) SE3000H-US/ SE3800H-US I Si I SE6000H-US / -.;.:..- 4,37' 0i , - , y4itti,A, .„,,,,, AC Output Voltage Min.-Nom: i / / / / Vac SE7600H-US /SE10000H-US/ SE1140011-US 44: ,. ;,,l'ff-iS- ' :-:-.,"1:i.c''1- . ir -1-: 4,- ,. -tr-l‹:rfr: '''-6-: *- - - +:-, :.-,,...„; AC Frequency(Nominal) 59.36060.51 Hz - - - _ - nartn,ni:70 \ontinuous Output 16 24 A 21 25 32 42 47.5 A -,,-' .. ;-', ''il'','"'-'-fitt:i:?s,''''--,: "--:'...,-,-, ""i.,-: :i':!:.',--,-,;,-"i„,.,.."4.:.'1,,,,,;",-:-- +(';:;,"-!i•t!t"; '".;'•4.:41;.', 123 16 .-- --T.-1,,,,m; m" .--,'4z-, :2%5, :,,,i,,, -;"'''"V-, 7'"' */, ''''''''• - ',' ---- iletArgtirti5';54.,:-, ""q"--!:,,,,,:' '"' ",(,-, , :',: • Yes Protection,Country Configurable ,,, ,, 3%-%03,!:!,:„ %I:; '3'3 33fA 0 solar:Er ..1* $4;i-:\.wt.,.:;,!--"-• -''' :1:2!* -;-:71,04,- -'-`51fr•i;'-:":'4.4-4:.- : -...f-tc.;-:,,t.--:--,41,,,,----...z-, ,.. k.„,1*,- -f::85.f. !-',.,:-17/,.:15--5,;"': "-:, •4•:-',Pi'ft•'-';'-.4-•N"'' Thresholds - ,-::--:.!. . INPUT W ,-,;,"..:1 - 1-",/,`-.-0!*-: --,,."- -- -4T:Lieft::-41.1f-- .-;, ,23:1,f ,:--,,, , . Maximum DC Power !!!. :"-",,:„(1.A,AiTir-''•, Transformer-less,Ungrounded 4650 I 5900 I 7750 1 9y3e00s , ,r-i ,:1:""' 3 , i;',.'.';'•:\:;•:t:-.: ,l'',5 ':;.... .,c.-- , 0!,,e Maximum Input Voltage 480 11800 I 15500 I 17670 Vdc 380 400 Vdc A" ,:, 4ty;'*ii ,-F '"''- ! ,' ; :k';:-...i. -v,,,: ii, -*or.7.:.-:,::!:,.::ti-•.t::T-,;-->:, ',.,:it,, I Nominal DC Input Voltage _ Adc . , ii - : i: 2,i,'"4":;.: 4'',-,44,- ' !lgi-lef - : -',I','!1-4-''.:,1:!1::';i"'A), '' - 9 13.5 - - 0 v) -..1 -;:.0-45; -,-. 10.5 13.5 163 20 27 30.5 Adc ;-: =4'4a‘ ':::: -..-,,-.7;i;- ,,,A-i3O,47,,,---:!.4,i'-, Yl..-! , ,-, ,',!:, . 8.5 Adc ,i,.24 '-: Maximum M a x i m u m Inputln p u Input Current Current 224008 VV 45 -4-----:1,4-!-.--'";:e?' " : 'fr., "-,.----. I MI "A,4 7:44,NiK: :''' „f-- ,--,:-' ,,,,,„?...-::" t.,,....,,,- : Max.Input Short Circuit Current !,,,,ir!'F-,, _, -,?'.0'-''', '''!-W, V,:;-,-:':T,,,'''';''‘, %'A':''-:1'.1-':',-..r;f?-1::..- '4- Reverse Polarity Protection Yes • 111/* * " "---,' l-4: * 600ku Sensitivity c; ",,,-:; `,:::-.;-:,:,:, 1.-";:-.i ,:,-,',!,Y';'-4,1,..'",,,:,... :3, ..., ,',1?",:' ,:':4;f-,'," Ground Fault Isolation Detection % 99.2 ,,,, .,-:- ;6::-Illt: - "------ - ..?-i-re:•;.- -ri;r0; Maximum Inverter Efficiency 99 I 4f. ' ' ' -: -)17'ilc,r!!'':1" --;:V_'. Y: , . 4'- '-'-'.t.;:;:it!'",,:,;,-,- -'--.44-,f,-I'. 99 % -i,,, :? --,-,, ::-.-+5, ..;.: ,, ,. ,, -, CEC Weighted Efficiency <2.5 W i .i3O j;.:;, `.'t•71:,: ..i:::-.."`'..- 4"--:f.,-Z"`, 2 -4.'4,41.tl+f- -;1-if-21-2'4 Nighttime Power Consumption --- i:::%,XraZtatC,Vert',:,3(V,K,P40,-.-- , • '•+ • ''''',;.::':.,it -;';'''' „--,-,'.7#,,,,,t-- '-',.. -",1'"."•"c•-• '--'-i;:'=. ADDITIONAL FEATURES , , , . --,;,-,,,,t4 ''7`.-i, Supported Communication RS485,Ethernet ZigBee(optional),Cellular(optional) • ) ',.,-;,4ir'52,, "1 ''", ,5-:---, 1-;.7 -,tt,z ' .'F4:7:`, ,,,..:, -,.',,:,:::) „” Interfaces _ '1";:-.0 :'- . t. -;:?tt'l ,;':".11.-rft„ Ir':".4, „;:'44liiVrt "7".,-rit,;-;- 7:;;:14:-.-. 5',-.:.'"r`J:- Revenue Grade Data,ANSI C12.20 Optiona IP) 0,40.fr' •'IP 0 0 " '-'?*, illi,::::t#Ifilir - --'--:::: ''',.,;;-t,rr,:::, ;„„---fr,-.''--4 "•-„- ' ,i- -,:tt',-:'. t',.'",---"'.:..r:-,:..1 . nor, -:-.--*,?:54,;•.t,„„i - :t--:;!..irrr, ';:iir:rr". 12 'i':!':24:!-4- ";:1- "4:!'i .'; irr'EE't 2R0a1p7id6S9houtiTwn-NEC 2014 and STANDARD COMPIJANCE Automatic Rapid Shutdown upon AC Grid Disconnect r „„ ',411. N.,4t !le Safety FCC Part 15 Class B 1,:iitt15-4:",-,11-!5*:t.:f":„Iiggetiai:-Aiiii:at,,, -1:•-'',4;!ii., -"kAiliitx- --:::,,,ztr-",ttlaliZti,” ""t;,.. ,:t i NSTALLATION SPECIFICATIONS 3/4''minimum/1-3 strings/ ''''"4-'1,11.7",:7' "''.'• '!4:2,-,44'.'"'-:.1 '''!4'-'7-1;I:1-e,'-'''""'"-.7t''f".1,-;'-';','''','-'t,,I,,:,:tik, r., -, -;-;:ov A '!..-7;rivii" !<:,7•, ,,,,:: o- ,1-' DC Input Conduit Size/#of Strings 3/4"minimum/1-2 strings/14-6 AWG 14-6 AWG k.m.:., --!, :r. ' . •..,,, „. : /AWG Range 21.3 x 14.6 21.3 x 14.6 ...„ - _ 5- „,.,! --',',”: . ' - . - --"p:,,- :- : r, .-51:;e5:515215Ni.,;::,. ..,' Dimensions with Safety Switch x 7.7/540x x 7.3/540 x in/mm -- -7" :=:--;--- -".:" .'• . :';''',"' 17.7x 14.6 x 6.8 /450 x 370x 174 „„ „„, , ,„ „ „ - "'"" '"" , . (HxWxD) 370 x 195 370 x 185 - Ofitliniziii iiistallatkoll wit ,',Ii„,::: ave technology ..':i:: -,,i,,,,,,,:, .. , -45.'J-:.-.A ,„": ,, : - . 22/10 I 25.1/11.4 I 26.2/11.9 38.8/17.6 40.1/18.2 lb/kg -, :.; - Weight with Safety Switch I <50 dBA <25 :::-.•,,* Specifically designed toworkwith poWer optimq;ers' .. ., Noise Natural convection and internal fan(user , - .--,- : + 1..,Record-breaking efficiency Natural Convection replaceable) Cooling - „,. • •- -13 to+140/-25 to+601°)(-40.F/-40.0 option)(5) *F/*C oi Ptted voltage inverter for longer strings ,t, . NEMA 3R(Inverter with Safety Switch) . . '.• a' Integrated arc fault protection and rapid shutdown for l--."r:+C14 and 2017,per a rti.r.:c r''t'::trl1.11 a ad 690.12 '•' oprpoeteractitinognTReamtipnegratu re Range •t -lir l')For other regional settings please contact SolarEdge support . al UL1741 SA certifie, -or CPUC Rule 21 grid complia t (2)Revenue grade inverter P/N:SExxxxH-USOOONNC2 --------w—Extfernely small {1„Foor Lwieorndpei-NratisnEg.infoHr_musoati000nNrNefue4r to:https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf .. High reliability without any electrolytic capacitors zilliill;HDP. 0 rro, Built-in module-level monitoring wave - ... .. :„. . - - - Outdoor and indoor laar.allation '-'--E:4 ' ::;;-- "':!",!'''':---:':';'- k.':---:: % .-. ,-, . i%li -i -.:.".. +. .t.- Opt.lr,re': IZ:.y.-rc,,e17,cti::: :trtz-,AN9 C12.2.0( .----, 'i.!:..;3.5%accuracy) — , .••<,.., ., +It•;,1 • ';': ' '?':::'' ''''''' ' ''''''''' ''ii,?:!:':',', '''''''. i'';F:',;:' , ;• , :4_,T,FV,ii,,';,•41„iWg,;;:' ,:';1„!,•::.''',- „. '''' Siniple c:aci:r-rr ari-o i;51t-lcon-lidc.,5.fir,,z•.-fi5i,5rnartph-,N:1 pp and built!r V‘.1-.H(SFI0000.1.1.,:;,.5E11400H-1.)S) -fro - RoH- ----,-- - -- - - --- - • -- -- - - ------,:-" .:,,,, ;„:4,,,,,,;,,,, ,,,t,,,,;,::: 4:give&SOLARE.ME.,..trit SisilatPfgkiogo.pptimizp),ax„a$4 , ,,,,,,, .:"-- www.solaredge.us 0 StilorEdgeloChitotogiestrto.AO rtght5,qY,S-- : 04 1"*Iittfortitoleniarkflitt,aftie000..4,?, ,: , aretiosioiroits or rAgisteiect USA-CANADA-GERMANY-UK-ITALY-THE NETHERLANDS-JAPAN-CHINA-AUSTRALIA-ISRAEL-FRANCE-BELGIUM-TURKEY-INDIA-BULGARIA-ROMANIA-HUNGARY-SWEDEN- SOUTH AFRICA-POLAND-CZECH REPUBLIC '""' ittaainorko or itioit respective tityners,;6,itert:11403.7b4/.'1:"940 NNik,StiliipMo,"r_ni0,49!:AG.441,45 ;;,,,,,E,J.,',,34,,, - -,". - , ,..,,,,,, - - .-!Y.' ',t :•:---t',' :.',Iit:W4„»V.--,•:I':!,,,,„ • " 't"-' .,";%ti-;:. . -,:15' ::: 't--- :-• „ , „ po veered by r MECHANICAL IFI " ,€ Q.ANTUM DUO gtrame) o=asmS (1685 x 3x.10 0 m x 0ncludin osasmm, � (1685mm x 1000mm x 40 mm) WeightIbs(20.2kg) �s=o,a°d•ew*P•°.=e•a••r Front Cover 0.13 in(3.2mm)thermally pre-stressed glass with anti-reflection technology z�h"`Po m•- Back Cover Composite film 3>=0,348mm, I _ Frame Black anodized aluminum - �� 9.•,=PPPmm Cell box 6 x 20 monocrystalhne Q.ANTUM solar half-cells ""'-[Il ���°°*,,, Junction 2.76-3.35in x 1.97 2 76in x 0.51-0.83in °3 a.mo. , (70-85mm x 50-70mm x 13-21mm),decentralized,IP67 P° points `h""' Cable 4mm2Solar cable;(+)>_43.3 in(1100mm),(-)>--43.3 in(1100mm) f �. rc Connector Multi-Contact MC4,IP68 °°3•a=m•r I T' ',.mm' EA K D u 0 B 1KG 5/SC 310-320LGHARATERISTIOS POWER CLASS 310 315 32U - ' , - 1, „,^3 , pEAK MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS,STC'(POWER TOLERANCE+5W/--OW) Power at MPP° PMPP [W] 310 315 320 Q.ANTUM SOLAR Short Circuit Current' Ise [Al 9.83 9.89 9.94 r... . �= _ Open Circuit Voltage° V. [VI 40.02 40.29 40.56 g Current at MPP' lMPP [Al 9.36 9.41 9.47 Voltage at MPP* VN,PP [VI 33.12 33.46 33.80 The new Q.PEAK DUO BLK-G5/SCsolar module from ELLS impresses Efficiency, rl [%l .18.4 >18.7 >-19.0 thanks to innovative P .°,. ,u,,. rt,,,,, Technology, which enables rticul rl MINIMUM PERFORMANCE AT NORMAL OPERATING CONDIIIONS,NOC' high performance on a small surface, and a black Zep CompatibleTM frame 1Power at MPP' PMPP [W1 229.7 233.5 237.2 design for improved aesthetics, easy installation and increased safety. Short Circuit Current° 1,c [Al 7.93 7.97 8.02 Q.ANTUMrS world-record-holding cell concept has nowbeen combined Open Circuit Voltage` V. [VI 37.43 37.69 37.94 Current at MPP` IMPP [Al 7.36 7.41 7.45 with State-of-tie-art circuitry half cells and asix-basher design, thus , IA," Voltage at MPP' VMPP [VI 31.20 31.52 31.84 achieving outstanding performance under real conditions - both witl1 '1000W/m'25°C,spectrum AM 1.50 =Measurement tolerances STC±3%,,NOC m5% '800W/m2,NOCT,spectrum AM 1.56 `typical values,actual values may differ low-intensity solar radiation as ell as on hot, clear summer days. a.CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE 10° At least 98%of nominal power during first year. .. ,a �uoa•d m„ ,w°„°ori `> Q.ANTUM TECHNOLOGY:LOW LEVELIZED COST OF ELECTRICITY industry for bend Thereafter max.0.54%degradation per year. ta ' aAt least 93.1%of nominal power up to 10 years. ,� Higher yield per surface area, lower BOS costs, higher power At least 85%of nominal power up to 25 years. I Classes, and an efficiency rate of up to 19.3%. .2 ooi-z = All data within measurement tolerances. . -I4 - 12 Full warranties in accordance with the warranty W terms of the Q CELLS sales organization of your INNOVATIVEALL-WEATHER TECHNOLOGY w espective country. '° ,� .0 a., Eo. r� Clip Optimal yields,whatever the weather with excellent low light = lakaofoecrtw�m=1 and temperature behavior. 7.° s .d a °P z' Typical module performance under low irradiance conditions in . 0,20,00.1;;,., o a;Pa"n•,,,m,,,z°,,, 'EARS comparison to STC conditions(25°C 1000W/m'). °� ENDURING HIGH PERFORMANCE CELLS " ,�- €€SEARCH � TEMPERATURE COEFFICIENTS ,111 Long-term yield security with Anti LID and Anti PID Technology', TOP BRAND PI/ ' ANTI PIOrbc Temperature Coefficient of IAr, s a [%/KI +0.04 Temperature Coefficient of V°c P [%/K] -0.28 M Hot-Spot Protect and Traceable Quality Tra.QT"". °q `E5 °,PROTECTN Y ` , EUROPE Te^perature Coefficient of PMPP y [%/K] -0.37 Normal Operating Cell Temperature NOCT I°Fl 113±5.4(45±3 C) Ash 2 018 . �sP, EXTREME WEATHER RATING P NTI LID,Ec�R°r°°v PROPERTIES ORSYS"E 'n .,`� High-tech aluminum alloy frame, certified for high snow "" Safet Maximum System Voltage V005 [VI 1000(IEC)/1000(UL) y Class II (5400 Pa)and wind loads(4000 Pa) regarding IEC. QGOMP41° Maximum Series Fuse Rating [A DCI 20 Fire Rating C(IEC)/TYPE 1(UL) Design load,push(UL), [lbs/ft'] 50(2400Pa) Permitted module temperature -40°F up to+185°F y n�4. `mss on continuous duty (-40°C up to+85°C) e A RELIABLE INVESTMENT • / • Design load,pull(UL)' [Ihs/ft'I 50(2400Pa) 'see installation manual € S Inclusive 12-year product warranty and 25-year - A, • linear performance guarantee,. �A�'�MPP�`w IALIFICATIONS AND CERTIFICATES P; NFORNI ON UL 1/03;CE-compliant; ftiumher of Modules per Pallet 26 _ '• r STATE OF THE ART MODULE TECHNOLOGY EC 61215(Ed.2);IEC 61730(Ed.1),application class A a Number of Pallets per 53'Trailer 32 Q.ANTUM DUO combines cutting edge cell separation ' APT test conditions according to s�oMPq,� Number of Pallets per 40'High Cube Container 26 0 methodIEC/TS 62804-1:2015, ® h _ and innovative wiring with Q.ANTUM Technology. V C B(-1500V,168 h) p E C E % W Pallet Dimensions(L x W x H) 69.3 in x 45.3 in x 46.9 to - ['rotUs See data sheet on rear for further (1760mm x 1150mm x 1190 mm) 2 ut leas 'De0MPP10 Insall c THE IDEAL SOLUTION FOR: information. Pallet Weight 12681bs(575 kg) o NOTE:Installation instructions must be followed.See the installation and operating manual or contact our technical service department for further information on approved installation and use Rooftop arrays on of this product. y commercial/industrial Hanwha 0 CELLS America Inc. buildings 300 Spectrum Center Drive,Suite 1250,Irvine,CA 92618,USA I TEL+1 949 748 59 96 I EMAIL inquiry@us.q-cells.com I WEB www.q-celis.us • Engineered in Germany 0 CELLS