Loading...
Report 000 ‘c) RECEIVED �� Stiff OS\N C\ 'LCI JAN 2 3 2019 CITY OF TIGARD BUILDING DIVISION SIEMENS 15201 NW Greenbrier Parkway Suite A-4 Beaverton,Oregon 97006 GO Phone: (503)207-1900 Fax:(503)207-1901 o, ' FIRE ALARM SUBMITTAL Washington Square Morphe Submittal Version Date Siemens Job Number 44OP-255987 Issued for Review 01 17.2019 Siemens Project Manager Moses Frangopolous Proprietary document for approval only TABLE OF CONTENTS SIEMENS BILL OF MATERIALS & COMPONENT SPECIFICATIONS FIRE ALARM POWER SUPPLY BATTERY AND VOLTAGE DROP CALCULATIONS CO W BILL OF MATERIALS SIEMENS FIRE ALARM SUBMITTAL Washington Square Fire Alarm System Panel Components Item Model# Siemens Part# Quantity Color Mfg Description 1 E60H-24MCC-FW 6 White Wheelock Multi-Candela Speaker/Strobe-White,Ceiling Mount-High Fideli 2 STW 1 White Wheelock Exceder Multi-Candela Strobe-White,Wall Mount 3 TRI-S 500-896225 1 Siemens MXL Single Input Monitor Module 4 EBA2001-U1 S54400-B140-A1 1 100 Watt Booster Amplifier Kit. Includes(1)of Each;EBA2004-A' 5 TRI-R 500-896224 1 Siemens MXL Control Relay Module w/Monitor Point 6 MR-201 1 Space Age Single DPDT Relay with LED * Catalog Cut Sheets not available PROPRIETARY DOCUMENT FOR APPROVAL ONLY 1/17/2019 Data Sheet Cerberus PRO Intelligent Voice Communication 100W Booster Amplifier and Components Vie ' ° Models: EBA2001-U1 or EBA2001-R1 (Kits); .aye: s&` EBA2004-A1 (Main Board) ARCHITECT AND ENGINEER SPECIFICATIONS ifiltArVgagit • Booster Amplifier provides additional 100 Watts of amplification for Cerberus PRO Intelligent Voice Communication(NC)systems a triand FireFinder®XLSV panels lelltkil _ , • Main board(Model EBA2004-A1)consists of two(2)50 ""'„ Watt amplifiers,configurable as 25V or 70V output . • Four(4)'ClassB'ortwo(2)'ClassA'whenconfiguredas100Wtotal a amplification"111..Priwattit ,ata” ,or two(2)'Class B'or one(1)'Class A'—configurable Y as(1)50W main and one(1)50W backup amplifierifM • ems , . • Supports high-level and low-level audio • . --- +, .• • One Audio Transformer Kit,Model FHA2054-U1,is required, (1) c6 for the calibration and amplification of low-level audio �.. <71 • Main board(Model EBA2004-A1),170W power supply '" ;,° • (Model FP2011-U1)and back-up batteries mount in an Inside a typical Booster enclosure specifically designed for booster amplifiers s Amplifier Enclosure ;, ' • Enclosure is available in either black(Model FH2O16-U1) $ - o , or red(Model FH2016-R1) "'i iii:i � _ •• Contains In/Out speaker connections , $% • General/AC/ground-fault trouble relays • Ground-fault detection wr -s>� 100W Main Board 7,F • Diagnostic light-emitting diodes(LEDs) Model EBA2004-A1 '4!45e'!":74 • Integrated battery charger Supports up to 33Ah batteries • ®UL 864 9th Edition Listed,®ULC-5527 Listed; : : • Up to 18Ah inside enclosure CSFM,NYCFD and OSHPD Approved ���` Product Overview .�� � Operating as a voice-amplification extender on When used with Siemens High-Fidelity speaker ," -.���� Siemens— Fire Safety voice panels, the Booster notification appliances, Model EBA2004-A1 meets the '-.1 Amplifier (in association with its related components) requirement for low-frequency(520 Hz)signal tone, per provides additional amplification to speaker circuits ®UL4641®ULC-5525,as described in the section, �� used on Cerberus PRO Intelligent Voice Determination of Low-Frequency Signal Format—Standard Ai , ..;', Communication (IVC) systems, as well as FireFinder Audible Signal Appliance: Suitable for Sleeping Areas As XLSV— both in bulk and distributed configurations. Required By NFPA 72 Chapter 18.4.5 (2013 Edition). The booster amplifier is available in two (2) types of The booster amplifier and its components are kits, Model EBA2001-U1IR1, each consisting of three ®UL864, ®UL1711,®UL2572 and ®ULC-5527 Listed. (3) main parts: # i � �� Additionally, Model EBA2001-U1 1 R1 is CSFM 7300- _ e ' ■ One(1) black or red booster-amp enclosure # # 0067:0274), NYCFD ( 6192) and OSHPD ( OSP-0420- (Model FH2O16 U1 I R1) 10) Approved. ' • One (1) main board, (Model EBA2004-A1) • One(1) 170W power supply,(Model FP2011-U1) Cerberus° PRO 9823 Fire Safety Products 100W Booster Amplifier and Components f ,ff . FifY rs fr infrasSIEMENS Product Descriptions Booster Amplifier Main Board Booster Amplifier Power Supply LIIIt0 Model EBA2004-A1 Model FP2011-U1 Model EBA2004 Al from Siemens—Fire Safety is the Model FP2011-U1 —used for supplying main power to a main board for the booster amplifier. Working as the Cerberus PRO 252 I 504-point addressable system—also supplies main power to a booster amplifier main board, primary component in voice-system amplification,the main board is used to provide additional 100W Model EBA2004-A1. amplification to speaker circuits on either a 252-point Consisting of up to 170 Watts,Model FP2011-U1 (Model FV922)or 504-point(Model FV924)addressable provides primary,filtered and regulated power. Model Cerberus PRO Intelligent Voice Communication system— FP2011-U1 is rated at 6.5 Amps at 24VDC, nominal. as well as with FireFinder®XLSV panels. The 170W power supply incorporates a 4.0A, non- Model EBA2004-A1 consists of one(1) integrated battery resettable slow-blow fuse on the primary input,and has charger and two(2) 50 Watt amplifiers on a single PC a built-in AC-line filter for surge and noise suppression. board—configurable to either 25V or 70V of output Model FP2011-U1 mounts from the inside (at the top)of power. The amplifiers are set as either 100W of total a Model FH2O16-U1 I R1 enclosure,and there are no amplification,or as a 50W main 150W back-up serviceable parts to be maintained. configuration. The main board supports two(2)'Class A'or four(4) Optional Accessories 'Class B'speaker circuits—when configured as 100W Booster Amplifier Battery Fixing Bracket amplification. Each 50W amplifier supports one(1) 1 r 'Class A'or two(2)'Class B'speaker circuits—when configured as a 50W main 150W back-up. Additionally, Model FHA2044-U1 Model EBA2004-A1 provides In I Out speaker For system installations in areas where Seismic connections and auxiliary contact(AC) power. certification is required, the booster amplifier battery- Ground-fault,AC failure, and general faults relays— fixing bracket is optionally used to secure up to as well as diagnostic LEDs are other features of Model 12V 118 Ah batteries in a Model FH2O16-series EBA2004-A1. The booster amplifier main board is booster-amplifier enclosure. configured by the use of DIP switches. Audio Transformer Kit Booster Amplifier Enclosure • i -V-. , IF Model FHA2054-U1 The Audio Transformer Kit (Model FHA2054-U1) is an Model FH2O16-U1 Model FH2O16-R1 optional component for the 100W Booster Amplifier Orderableused with Cerberus PRO IVC panels, as well as with in either black or red,the Booster Amp FireFinder XLSV. The kit,which serves as the low-level Enclosure houses one(1) booster-amp main board audio-input source to drive the Booster Amplifier, (Model EBA2004-A1);one(1) 170W power supply provides reliable ground isolation for low-level audio. (Model FP2011-U1),and one(1)battery up to 18Ah inside the enclosure. Each order of Model FHA2054-U1 is shipped with a shield NOTE: Since the booster amplifier main board (Model isolation terminal block;a terminal block(for the wiring to EBA2004-A1) requires up to 33Ah of operating the"low-level"input),as well as an isolating transformer power,an additional back-up battery must be used module with a connector(for the low-level audio and mounted in a Model FH2O16-series enclosure. connection and the terminating resistor for supervision). SIEMENSIndustry, Inc. Cerberus® PRO Building Technologies Division Technical Data Voltage,nominal 24VDC Integrated - - -------- - - -- - - - - - - Outputcurrent, max. 6.5A Battery ----- - -------- Charge voltage,max. 27.3VDC Charger - - - Charge current,max. 1.5A ®UL: 450 Hz (3 kHz) Frequency range ®ULC 375 Hz (7 kHz) Audio Line Input level,max. 1.55 11.0 1 0.75 VRMS or OFF, selectable Input Impedance p [Model EBA2004-Al] 604)@ 1 kHz Impedance [Model FHA2054-U1] 10kII @ 1 kHz AC Input: 2.OA @ 115 1 230 VAC(50160 Hz) 1 70W` DC Output: 6.5A @ 26VDC POW@r Supply Input pp y Characteristics: Voltage: 26VDC [Model FP2011-U1] Current Draw,max. 6.5 Amps. 100W Booster Dimensions: 8.66"—x— 1.69"—x— 13.39" Amplifier: {W—x—H—x—D} (22 cm. —x—4.3 cm.—x—34 cm.) [Model EBA2004-Al] Weight: 0.044 Lbs. (20g) Physical Properties Enclosure for the Dimensions: 18.1"—x—23.6"—x—5.2" 100WBooster {W—x—H—x—D} (46 cm.—x-60 cm.—x— 13.2 cm.) Amplifier: Weight: [Model FH2016-U11R1] (Approximate) 44 Lbs. (20 kg.) NOTES: For more technical data for the Booster Amplifier,go to - IOM:A6V10407858. For more technical data on the Model FH2O16-series enclosure,go to - IOM:A6V10437426. For more technical data on the Model FHA2044-U1 fixing bracket,go to - IOM:A6V10437428. For more technical data on the Model FHA2054-U1 audio transformer kit,go to 4 IOM:A6V10590197. Details for Ordering Details for Ordering - (continued) -Booster Amp Kits- -Parts- Model Part Description Model Part Description Number Number 100W Booster Amplifier Kit, Black EBA2004-A1 S54400-8137-A1 100W Booster Amplifier Consists of the following : - one(1) main board FH2O16-U1 554400-B138-A1 100W Booster Amplifier EBA2001-U1 S54400- (Model EBA2004-A1); Enclosure, Black B140-Al one(1) black enclosure 100W Booster Amplifier FH2O16-R1 554400-B136-A1 (Model FH2016-U1), Enclosure, Red - one(1) 170W power supply, FHA2044-U1 S54400-B167-A1 Battery Fixing Bracket (Model FP2011-U1) FHA2054-U1 S54400-B58-A1 Audio Transformer Kit 100W Booster Amplifier Kit, Red Consists of the following : FP201 1-U1 500-450222 170 Watt Power Supply - one(1) main board EBA2001 R1 S54400- (Model EBA2004-A1); Related Documentation B141-Al - one(1) red enclosure Data Sheet Number (Model FH2O16-R1), Cerberus PRO Intelligent Voice Communication 9821 - one(1) 170W power supply (Model FP201 1-U1) FireFinder XLSV 6340 SIEMENSIndustry, Inc. Cerberus® PRO Building Technologies Division - i SIEMENS Cerberus° PRO NOTICE—The information contained in this data-sheet document is intended only as a summary,and is subject to change without notice. The devices described here have specific instruction sheets that cover various technical,limitation and liability information. Siemens Industry,Inc.—Building Technologies Div. Copies of these instruction sheets and the General Product Warning and Limitations 8 Fernwood Road • Florham Park, NJ 07932 document,which also contains important information,are provided with the product and,are Tel: (973) 593-2600 • Fax: (908) 547-6877 available from the Manufacturer. :.Data contained in these documents should be consulted before specifying or using the product. Web:www.USA.Siemens.com/Cerberus-PRO For further data or assistance concerning particular problems contact the Manufacturer. Building Technologies Division April 2016—Supersedes sheet dated 5/2015 SI!–Fire Safety (Rev.1) [Printed in U.S.A SIEMENS Data Sheet Fire Safety& Security Products Intelligent Detection Devices TRI Series — Intelligent Initiating Interface Modules [For use with Firerinder® XLS and MXL Panels] Models TRI-D, TRI-R and TRI-S ARCHITECT AND ENGINEER SPECIFICATIONS • Used as an intelligent initiating interface module for the FireFinder XLS and MXL fire-alarm control panels(FACPs) • Interfaces and supervises normally open (N.0)contacts Integral single-pole,double-throw(SPDT)relay(up to 4 amps),Model TRI-R • Dual input for Model TRI-D • Multi-color light-emitting diode(LED)indicates detector status (green,amber, red) • • Simple front-end access to programming port and wiring terminals • Mounts in a 4"-square, 2-1/8"-deep standard or double-gang box 'evr 'feel • Dynamic supervision * • 5-x-5-inch faceplate included £ ',9 • Two-wire operation "'" .m' 3 i • Compatible with Model DPU or FPI-32 field programmer/tester •"4.. • Electronic-address programming is simple and dependable • ®UL Listed,€ULC Listed; CSFM and NYC Fire Department Approved Product Overview The Model TRI-series of intelligent interface The sole purpose of Model TRI-S is to monitor and modules from Siemens—Fire Safety is designed to report the status of the contact,while Model TRI-R provide the means of interfacing direct shorting incorporates an addressable'Form C'relay. The devices to Model MLC for the FireFinder XLS FACP, relay and contact device input for Model TRI-R are or to Model ALD for the MXL system, respectively. controlled at the same address. The relay and input The Model TRI-series of intelligent interface contact can be controlled as a separate function. modules provides the most advanced method of The relay is typically used where control or shunting address programming and supervision—combined of external equipment is required. with sophisticated FACP communication. Each Model TRI-D is a dual-input module that is designed to Model TRI-series interface module incorporates a supervise and monitor two (2) sets of dry contacts. microcomputer chip. In turn,the microcomputer- Model TRI-D requires two(2) address settings. Model chip technology and its sophisticated bi-directional TRI-D is ideal for monitoring a waterflow switch and its communication capabilities with the FACP,achieve respective valve tamper switch. the state of an'Intelligent Device.' Model TRI-series has a multi-color LED that flashes Specifications green when operating normally;amber, if unit is in trouble condition, and red to indicate a change of The Model TRI series of intelligent interface modules is available in three (3) models. Models status command. Model TRI-D flashes two (2)times— TRI-S and TRI-R are designed to monitor a normally once for each address, and the red LED of Model TRI-R open (N.O.)dry contact. The interface module indicates a change of state in the relay. reports the contact's status to the FACP. TRI Series—Intelligent Initiating Interface Modules 61 79 SIEMENS Industry, Inc. Building Technologies Division Specifications — (continued) Electrical Ratings The microcomputer chip for the Model TRI-series of Current Draw: 11: 1.5mA devices has the capacity of storing—in memory— [Active or Standby] identification information as well as important Model TRI-R Relay Ratings: operating status information. 4A,125VAC Resistive: 4A,30VDC Siemens—Fire Safety innovative technology allows all Model TRI-series intelligent interface modules to 3.5A,120VAC[0.6 P.F] be programmed and tested,via Model DPU or the 3.0A,30VDC[0.6 P.F] Inductive: 2.0A,120VAC[0.4 P.F] FPI-32 Programmer I Tester. Each of these 2.0A,120VAC[0.35 P.F] programmer I testers is a compact,portable and 2.0A,120VAC[0.35 P.F] menu-driven accessory that makes programming and testing an interface device faster,easier and more dependable than previous methods. Mounting Diagram Model DPU or the FPI-32 eliminates the need for MOUNTING SLOTS mechanical addressing mechanisms (such as: FOR 4-INCH program jumpers, DIP switches,or rotary dials), swiTcriBOX since either programmer I tester device electronically sets the address of the Model TRI- series series into the interface's microcomputer-chip, non- TRI-S/0/R volatile memory. Vibration,corrosion and other Ir! , 1.1 I MODULE conditions that deteriorate mechanical addressing q s] �Q mechanisms are no longer a cause for concern. L4 t fa9DUNTltic The Model TRI-series of intelligent interface 115s HOLES POR modules is fitted with screw terminals for TE connection to an addressable circuit,and is fully compatible on the same circuit with all intelligento Cit Model FP; Model IL and Model ID-60-series detectors;Model MSI Series addressable manual stations,or any other addressable intelligent MOUNTING SLOTS modules,such as Model CZM or Model ICP. FOR DOUBLE-GANG MATCHBOX All Model TRI-series intelligent interface modules are®UL and OULC Listed. Details for Ordering Model Part Shipping Weight Description Number Number Oz. ( Kg. Dual-Input Intelligent 7 0 2 TRI-D 500-896226 Interface Module Single-Input[WI relay] TRI-R 500-896224 Intelligent Interface 7 0.2 Module Single-Input TRI-S 500-896225 Intelligent Interface 7 0.2 Module Notice: This marketing data sheet is not intended to be used for system design or installation purposes. For the most up-to-date information,refer to each product's installation instructions. Fire Safety Fire Safety 8 Fernwood Road 2 Kenview Boulevard SIEMENS Industry,Inc. Florham Park,NJ 07932 Brampton,Ontario Jul 2012 Tel:(973)593-2600 (sii-rs) L6T 5E4/Canada Supersedes y 2 dated 5/06 Building Technologies Division Tel:(905)799-9937 FAX:(908)547-6877 Printed in U.S.A. (Rev I) URL:www.usa.Siemens.com/Fire FAX:(905)799-9858 Effective January 2016 Technical Data TD450017EN supersedes January 2015 Wheelock E5OH & E6OH High Fidelity Speakers & Speaker Strobes : �-- Description The Wheelock E50H Wall and E60H Ceiling Speakers and Speaker Strobes are designed for high fidelity sound output for indoor applications. With the widest frequency response range(300 t.*+* to 8000 Hz)in the industry,the EH product line features leading intelligibility with crisp,clear voice messages and tone signaling, ideal for emergency communications, mass notification,and voice evacuation. Providing a sleek aesthetic appearance,the wall and ceiling appliances feature dual voltage(25/70 VRMS)capability and field-selectable taps from 1/8 to 2 watts. For faster and easier installation,the low profile design incorporates a speaker mounting ,•°'; plate,and each model has a built-in level adjustment feature and snap-on cover with no visible mounting screws. ° For visible signaling to meet the hearing impaired,the Series EH Speaker Strobe models incorporate the low current draw of the RSS Strobes. Strobe options for wall mount models include Wheelock patented ••tttttt MCW multi-candela strobe with field selectable candela settings of 15/30/75/110cd or the high intensity MCWH strobe with field selectable 135/185cd. Ceiling mount models are available in Wheelock patented MCC multi-candela ceiling strobe with field selectable intensities of 15/30/75/95cd or the high intensity MCCH strobe with field selectable 115/177cd. The strobe portion of all Series EH Speaker Strobes may be synchronized when used in conjunction with the Wheelock DSM Sync Modules,Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol. Wheelock synchronized strobes offer an easy way to comply with ADA recommendations concerning photosensitive epilepsy. Series EH Speaker Strobes are UL Listed for indoor use under Standard 1971 (Signaling Devices for the Hearing-Impaired)and Standard 1480(Speaker Appliances),and ULC listed under CAN/ ULC-S526(Visual-audible Signal Appliances,Fire Alarm)and under CAN/ULC-S541 (Speakers, Fire Alarm). All inputs employ IN/OUT wiring terminals for fast installation using#12 to#18 AWG wiring. Color options for the Series EH Speakers and Speaker Strobes are red and white. • i N Powering Business Worldwide Technical Data TD450017EN Wheelock E5OH &E6OH High Fidelity Effective January 2016 Speakers&Speaker Strobes Features Drawings • High Fidelity Sound Output 5.00 47 6- • Efficient design for high intelligibility at minimum wattage across a frequency range of 300 to 8000 HZ • 6 Field Selectable Settings in 1 Device e+ il - Wall mount models are available with Field Selectable Candela 000000 0 00 -'!r Settings of 15/30/•75/110cd or 135/185cd(Multi-Candela models) °so og00%000 iI'II or 1575cd(Single Candela model) • Ceiling mount models are available with field selectable candela o°oo Mir Ila settings of 15/30/75/95cd or 115/177cd(Multi-candela models) • Field Selectable Taps • 1/8 watt up to 2 watts • 25 or 70 VRMS operation ,_6 • Easy-to-Install • Low profile design incorporates speaker mounting plate for faster and easier installation sss° 1IIi'#12 to • #18 AWG wires ►� • 4" square backbox prevents wire damage - Series E50H-No extension ring required • Series E60H-Optional Extender(E60 Ext)is available for mounting to 4" square backboxes • Strobe Synchronization Components Figure 1.E501-I(top)and E6OH(bottom)Speakers-Front&Side Views • Meet synchronizing standards with Wheelock's DSM Sync Modules, PS Power Supplies or SAFEPATH products5.00 66 I 1.46-- • Compliance , • UL 1971, UL 1480, ULC-S526, ULC-5541 — I ¢� ] �r l • Low frequency requirements of UL 464(520 Hz)to meet ` NFPAs 520 Hz tone requirements for sleeping areas • California State Fire Marshal(CSFM) ill • ADA/NFPA/ANSI/OSHA • oto aw Q ill- 1111' i I 'I I'i • FCC Part 15,ICES OP .Cil Note: All CAUTIONS and WARNINGS are identified by the symbol A.All °°°° warnings are printed in bold capital letters. L1.40-1 3.020 A WARNING 62.385 H 2.22 PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING,SPECIFYING OR APPLYING THIS PRODUCT.VISIT WWW.EATON.COM/MASSNOTIFICATION OR CONTACT EATON FOR THE CURRENT INSTALLATION INSTRUCTIONS. ' Wi le* FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS,CAUTIONS OR o�° WARNINGS COULD RESULT IN IMPROPER APPLICATION,INSTALLATION " I�� ���atrAND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, • ,,000aao WHICH COULD RESULT IN PROPERTY DAMAGE,AND SERIOUS INJURY OR • °gooea°o DEATH TO YOU AND/OR OTHERS. Figure 2.E6OH(top)and E6OH(bottom)Speaker Strobes-Front&Side Views General Notes • Strobes are designed to flash at 1 flash per second minimum over their"Regulated-Voltage Range" Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective Strobe intensity based on UL 1971. 2 EATON www.eaton.com Wheelock E5OH &E6OH High Fidelity Technical Data TD450017EN Speakers&Speaker Strobes Effective January 2016 Table 1. Maximum RMS Current UL/ULC Max Current a 24MCW/24MCC 24MCWH/24MCCH 241575W Regulated Voltage Model Range VDC 15 30 75 95 110 115 135 177 185 E5OH 16.0-33.0 0.060 0.092 0.165 0.220 0.300 0.420 E6OH 16.0-33.0 0.060 0.105 0.189 0.249 0.300 0.420 Table 2. UL Listed Models and Ratings UL Reverberant dBA at 10 Feet b Model 1/8 watts 1/4 watts 1/2 watts 1 watts 2 watts E5OH Speaker Strobe 73 76 79 82 84 E6OH Speaker 74 77 80 83 85 E6OH Speaker Strobe 74 77 80 82 85 Table 3. Specification&Ordering Information Mounting Sync w/DSM or Model Order# Strobe Candela Red White Lettering Wall Ceiling Options Wheelock Power Supplies Speakers E5OH-R 9863 X No Lettering X E,AA E50H-W 9864 X No Lettering X E,AA E50H-ALW 3577 X ALERT X E,AA E60H-R 9867 X No Lettering X E E60H-W 9874 X No Lettering X E E60H-ALW 3554 X ALERT X E Speaker Strobes E5OH-24MCW-FR 0092 15/30/75/110 X FIRE X E,BB X E50H-24MCW-FW 0093 15/30/75/110 X FIRE ` X E,BB X E50H-24MCW-ALR 3559 15/30/75/110 X ALERT X E,BB X E50H-24MCW-ALW 3560 15/30/75/110 X ALERT X E,BB X E50H-24MCW-NW 3575 15/30/75/110 X No Lettering X E,BB X E5OH-24MCWH-FR 0094 135/185 X FIRE X E,BB X E50H-24MCWH-FW 0097 135/185 X FIRE X E,BB X E50H-24MCWH-ALW 3561 135/185 X ALERT X E,BB X E60H-24MCC-FR 0187 15/30/75/95 X FIRE X E X E60H-24MCC-FW 0188 15/30/75/95 X FIRE X E X E60H-24MCC-NW 0950 15/30/75/95 X No Lettering X E X E60H-24MCC-ALW 3555 15/30/75/95 X ALERT X E x E60H-24MCCH-FR 0189 115/177 X FIRE X E x E60H-24MCCH-FW 0190 115/177 X FIRE X E x Extender Ring E60EXT-R° 3578 X E60EXT-W° 3757 X Table 4. Specifications Physical Material/Lens(Material type) Red or white textured UV stabilized,colored impregnated engineered plastic.Exceeds 94V-0 UL flammability rating./ GE LEXAN 943A Weight E5OH Speaker:1.5 lbs(0.68 kg);E5OH Speaker Strobe 1.6 lbs(0.73 kg);E6OH Speaker:1.6 lbs(0.73 kg);E6OH Speaker Strobe 1.7 lbs(0.77 kg); Dimensions E5OH Speaker: 5"W x 5"H x 1.47"D;E5OH Speaker Strobe: 5"W x 6.74"H x 2.58"D;E6OH Speaker:7.38"Diameter x .83"D;E6OH Speaker Strobe:7.38"Diameter x 3.02"D Operating Temperature Indoor:33.8°F to 120.2°F(0°C to 49°C)and maximum humidity of 93% Mounting&Wire Connections Mounting(indoor only) 4"square backbox prevents wire damage;Series E5OH-No extension ring required;Series E6OH-Optional Extender (E60 Ext)is available for mounting to 4"square backboxes,E50 SSB,E50 SB for surface mount of E5OH Wire Connections #12 through#18 AWG Power&General Operating voltage 25/70 VRMS Strobe Output Rating UL 1971,ULC S526 Strobe Flash Rate Strobes are designed to flash at 1 flash per second Synchronization Models Strobes can be synchronized with Wheelock's DSM Sync Modules,PS Power Supplies or SAFEPATH products,using Wheelock patented sync protocol Frequency Range 300 Hz to 8000 Hz a RMS current ratings are per UL maximum RMS method.UL max current rating is the maximum RMS current within the listed voltage range(16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage(16v for 24v units). For audibles the max current is usually at the maximum listed voltage(33v for 24v units). For unfiltered FWR ratings,see installation instructions. b dBA ratings are based on testing under UL Standard 1480. c 1/8 watt tap is for private mode only. d E60 EXT is an attractive extender ring that mounts behind the speaker to permit mounting to a 4"square x 2 1/8"deep electrical box without need for an extension ring on the box. EATONwww.eaton.com 3 Technical Data TD450017EN Wheelock E5OH &E6OH High Fidelity Speakers&Speaker Strobes Effective December 2015 Architects and Engineers Specifications Wheelock E50H-The speaker appliances shall be Wheelock E5OH Wheelock E6OH-The speaker appliances shall be Wheelock High Fidelity Speakers,and the High Fidelity Speaker Strobe appli- E6OH High Fidelity Speakers,and the High Fidelity Speaker Strobe ances shall be Wheelock E5OH Speaker Strobes or approved equals. appliances shall be Wheelock Series E6OH Speaker Strobes or The speakers shall be UL Listed under UL 1480 for Fire Protective approved equals.The speakers shall be UL Listed under UL 1480 Service and speakers equipped with strobes shall be listed under UL for Fire Protective Service and speakers equipped with strobes shall 1971 for Emergency Devices for the Hearing-Impaired.In addition, be listed under UL 1971 for Emergency Devices for the Hearing- the strobes shall be certified to meet the requirements of FCC Part Impaired. In addition,the strobes shall be certified to meet the 15,Class A. requirements of FCC Part 15,Class A. All speakers shall be designed for a field selectable input of either All speakers shall be designed for a field selectable input of either 25 25 or 70 VRMS,with selectable power taps from 1/8 watt to 2 or 70 VRMS,with selectable power taps from 1/8 watt to 2 watts. watts.All models shall have listed sound output of up to 87 dB at All models shall have listed sound output of up to 87 dBA at 10 feet 10 feet and a listed frequency response of 300 to 8000 Hz.The and a listed frequency response of 300 to 8000 Hz.The speaker speaker shall also incorporate a sealed back construction.All inputs shall incorporate a sealed back construction.All inputs shall employ shall employ terminals that accept#12 to#18 AWG wire sizes. The terminals that accept#12 to#18 AWG wire sizes. The strobe portion strobe portion of the appliance shall produce a flash rate of one(1) of the appliance shall produce a flash rate of one(1)flash per second flash per second over the Regulated Voltage Range.The strobe shall over the Regulated Voltage Range and shall be of low current design. be of low current design.Where Multi-Candela Speaker Strobes are Where Multi-Candela Speaker Strobes are specified,the strobe specified,the strobe intensity shall have field selectable settings intensity shall have field selectable settings and shall be rated per and shall be rated per UL 1971 15/30/75/95cd or 115/177cd for UL 1971 at 15/30/75/110cd or 135/185cd for wall mounting. The ceiling mount. The selector switch for selecting the candela shall selector switch for selecting the candela shall be tamper resistant. be tamper resistant. When synchronization is required,the strobe portion of the appliance shall be compatible with Wheelock DSM When synchronization is required,the strobe portion of the sync modules or the Wheelock Power Supplies with built-in Patented appliance shall be compatible with the Wheelock's DSM sync Sync Protocol.The strobes shall not drift out of synchronization at modules or Wheelock Power Supplies with built-in Patented Sync any time during operation. If the sync module or Power Supply fails Protocol.The strobes shall not drift out of synchronization at any to operate, (i.e.,contacts remain closed),the strobe shall revert to a time during operation. If the sync module or Power Supply fails to non-synchronized flash rate. operate, (i.e.,contacts remain closed),the strobe shall revert to a The speaker and speaker strobe appliances shall be designed non-synchronized flash rate. for indoor flush mounting.The speaker and speaker strobe shall The speaker and speaker strobe appliances shall be designed for incorporate a speaker mounting plate with a snap-on grille cover indoor flush mounting to 4" x 2-1/8"electrical boxes without need with no visible screws for a level,aesthetic finish and shall mount to for an extension ring or surface mounting to Wheelock's E5OSB standard electrical hardware. The finish of the Series E6OH Speakers or E5OSSB surface boxes.The speaker and speaker strobe shall and Speaker Strobes shall be white or red. All speaker and speaker incorporate a speaker mounting plate with a snap-on grille cover.The strobe appliances shall be backward compatible. finish of the Series E5OH speakers and speakers strobes shall be The speaker shall be listed to the low frequency requirements of UL white or red. 464(520 Hz)to meet NFPAs 520 Hz tone requirements for sleeping The speaker shall be listed to the low frequency requirements of UL 464 areas. (520 Hz)to meet NFPAs 520 Hz tone requirements for sleeping areas. UL 1971, UL 1480, ULC-5526, ULC-S541,CSFM, FCC. UL 1971, UL 1480, ULC-S526, ULC-S541,CSFM,FCC. Note:Due to continuous development of our products,specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc.,dba Eaton standard terms and conditions. Member W( ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Eaton 1000 Eaton Boulevard Cleveland,OH 44122 United States Eaton.com Eaton Life safety&mass notification solutions 273 Branchport Ave. Long Branch,NJ 07740 www.eaton.corn/massnotification *2016 Eaton All Rights Reserved Eaton is a registered trademark. ET• Printed in USA � Publication No.TD450017EN All other trademarks are property Powering Business Worldwide January 2016 of their respective owners. HN Series Effective October 2014 HS Series Technical Data TDO01017EN Supersedes May 2013 ST Series Exceder Strobe, Horn Strobe, and Horn Notification Appliances Description The Wheelock Exceder Series of notification appliances 4 it 1, I7 11.777 4:",,,s.::- A ' feature a sleek modern design that will please building owners with reduced total cost of ownership. Installers will benefit from its comprehensive feature list,including the most candela options in one appliance,low current draw,no tools needed for setting changes,voltage test points, 12/24 VDC operation, universal mounting base and multiple mounting options for both new and retrofit construction. i I The Wheelock Exceder Series incorporates high reliability and high / FIRE E efficiency optics to minimize current draw allowing for a greater number of appliances on the notification appliance circuit.All strobe P" models feature an industry first of 8 candela settings on a single ,,.. appliance. Models with an audible feature 3 sound settings(90,95, ,`, 3i, 4' '`h 99 dB).All switches to change settings,can be set without the use ^ '? �•'/ x` of a tool and are located behind the appliance to prevent tampering. —{J Wall models feature voltage test points to take readings with a /? i voltage meter for troubleshooting and AHJ inspection. The Wheelock Exceder Series of wall and ceiling notification ,' appliances feature a Universal Mounting Base(UMB)designed to simplify the installation and testing of horns,strobes,and combination horn strobes.The separate universal mounting base can be pre-wired to allow full testing of circuit wiring before the appliance is installed and the surface is finished.It comes complete . with a Contact Cover for protection against dirt,dust,paint and damage to the contacts.The Contact Cover also acts as a shunting device to allow pre-wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while it is on the UMB. When the Contact Cover is removed the circuit will show an open until the appliance is installed.The UMB allows for consistent installation and easy replacement of appliances if required.Wall models provide an optional locking screw for extra secure installation,while the ceiling models provide a captivated screw to prevent the screw from falling during installation. ET•N Powering Business Worldwide Technical Data TD001017EN HN Series HS Series Effective October 2014 ST Series Features • Environmentally friendly • Low current draw • Sleek modern aesthetics • Up to 9 models now in 1 appliance draw@ • Finger slide switches • 12/24VDC on a single appliance • Voltage test points • Easy to remember model numbers • Multiple voltages O Patented • 3 Audible settings Note:All CAUTIONS and WARNINGS are Identified by the symbol A.All • 90,95,99 dB warnings are printed in bold capital letters. • Industry leading-8 candela settings on 1 device • Wall: 15/1575/30/75/95/110/135/185 A WARNING • Ceiling: 15/30/60/75/95/115/150/177 PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING,SPECIFYING OR APPLYING THIS PRODUCT.VISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPER NOTIFICATION FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS,CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION,INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE,AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes • Strobes are designed to flash at 1 flash per second minimum over their"Regulated Voltage Range" • All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. • Series Exceder Strobe products are Listed under UL Standards • Universal mouting base 1971 and 464 for indoor use with a temperature range of 32°F to • Ceiling and wall 120°F(0°C to 49°C)and maximum humidity of 93% (±2%) UL ® Mounts to 5 backbox types: 1 gang,2 gang,4" square, 464(85% UL 1971). 3.5"octal.&4"octal.(100mm for international customers) • Series Exceder horns are under UL Standard 464 for audible signal appliances(Indoor use only). Universal mounting base Contact cover �4 ����� � �� �'��� Compatibility and requirements 1' 4 • Synchronize using the Wheelock®Sync Modules or panels with ,,,, it ,,,, ;.,0 ,v �,�3 built-in Wheelock°Patented Sync Protocol le a ., ,' gi hu ,t 4 ,t • Compatible with UL"Regulated Voltage" using filtered VDC or ) unfiltered VRMS input voltage 1` : �r "rr''rt • Strobes produce 1 flash per second over the "Regulated '., Voltage" range Common base for wall and ceiling with 5 mounting options Compliance • Voltage test points for quick troubleshooting and easy spot • UL 1971, UL 464, ULC,CSFM, FM checking (wall models only) • ADA/NFPA/ANSI/OSHA • RoHS ""'''''''''''#'it 7:\\*\ lk,,,. i't - 1$ v n 2 EATON www.eaton.com HN Series Technical Data TD001017EN HS Series Effective October 2014 ST Series Table 1. Strobe Ratings per UL Standard 1971 UL Max Current® 24 VDC/24 FWR 12 VDC Regulated Voltage Model Range VDC 15 15/75 30 80 75 95 110 115 135 150 177 185 15 15/75 ST 8.0-33.0 0.057 0.070 0.085 - 0.135 0.163 0.182 - 0.205 - - 0.253 0.110 0.140 STC 8.0-33.0 0.061 - 0.085 0.103 0.135 0.163 - 0.182 - 0.205 0.253 - 0.110 - Table 2. Horn Strobe Ratings per UL 1971 &Anechoic at 24VDC UL Max Current®at Anechoic 99 dBA 24 VDC 12 VDC Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.082 0.095 0.102 - 0.148 0.176 0.197 - 0.242 - - 0.282 0.125 0.159 HSC 8.0-33.0 0.082 - 0.102 0.141 0.148 0.176 - 0.197 - 0.242 0.282 - 0.125 - UL Max Current®at Anechoic 95 dBA 24 VDC 12 VDC Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.073 0.083 0.087 - 0.139 0.163 0.186 - 2 0. 30 - - 0.282 0.122 0.153 HSC 8.0-33.0 0.073 - 0.087 0.128 0.139 0.163 - 0.186 - 0.230 0.272 - 0.122 - UL Max Current®at Anechoic 90 dBA 24VDC 12VDC Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.065 0.075 0.084 - 0.136 0.157 0.184 - 0.226 - - 0.267 0.120 0.148 HSC 8.0-33.0 0.065 - 0.084 0.120 0.136 0.157 - 0.184 - 0.226 0.267 - 0.120 - r0 UL max current rating is the maximum RMS current within the listed voltage range(16-33 VDC for 24 VDC units).For strobes the UL max current is usually at the minimum listed voltage 116 VDC for 24 VDC units).For audibles the max current is usually at the maximum listed voltage 133 VDC for 24 VDC units).For unfiltered ratings,see installation instructions. Table 3. Horn Ratings per UL Anechoic Model Legend Regulated Voltage Model Range VDC 99 dB 95 dB 90 dB HN = Horn R = Red HN 16-33.0 0.064 0.044 0.022 ST = Strobe A = Agent Lettering(strobes only) HNC 16-33.0 0.084 0.044 0.022 HS = Horn Strobe AL = Alert Lettering(strobes only) HN 8.0-17.5 0.047 0.026 0.017 C = Ceiling Mount N = No Lettering(strobes only) HNC 8.0-17.5 0.047 0.026 0.017 W = White Example 1:STRC=Strobe,Red,Ceiling Mount Table 4. Specification&Ordering Information Example 2:HSR=Horn Strobe,Red,Wall Mount Sync w/DSM or Example 3:HSW=Horn Strobe,White,Wall Mount l heelock Power 12/24 Mounting Example 4:STW-AL=Strobe,White,Wall Mount,Alert Lettering Model Strobe Candela Supplies VDC® Options Horn Strobes HSR 15/1575/30/75/95/110/135/185 X X LIMB® sic HSW 15/1575/30/75/95/110/135/185 X X UMB® :"`` . HSRC 15/30/60/75/95/115/150/177 X X UMB® HSWC 15/30/60/75/95/115/150/177 X X UMB® 'w " 4 r , °' Strobes /. '""' STR 15/1575/30/75/95/110/135/185 X X UMB® ~+.••• STW 15/1575/30/75/95/110/135/185 X X UMB® `' STRC 15/30/60/75/95/115/150/177 X X UMBO' ,1`l STWC 15/30/60/75/95/115/150/177 X X LIMB® Horn , . « HNR X X UMBO ■ / HNW X X LIMB® HNRC X X LIMB® Example:HSR Example:HSWC HNWC X X UMB® OO 12 VDC models feature 15&15/75 settings OO UMB=Universal Mounting Base EATON www.eaton.com 3 Technical Data TD001017EN HN Series Effective October 2014 HS Series ST Series Architects and Engineers Specifications The notification appliances shall be Wheelock Exceder Series HS Audible Strobe appliances,Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals.The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired)for Indoor Fire Protection Service.The Series HS and HN Audibles shall be UL Listed under Standard 464(Fire Protective Signaling).All Series shall meet the requirements of FCC Part 15 Class B.All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel(FACP)with the ability to operate from 8 to 33 VDC.Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one(11 flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan®lens.The Series shall be of low current design.Where multi- candela appliances are specified,the strobe intensity shall have 8 field selectable settings at 15, 15/75,30,75,95, 110, 135, 185 candela for wall mount and 15,30,60,75,95, 115, 150, 177 candela for ceiling mount.The selector switch for selecting the candela shall be tamper resistant.The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g.,ADA compliance).Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three(3)field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3)audible outputs. The Series HS Audible Strobe,ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single-gang,double-gang,4-inch square,3.5-inch octal,4-inch octal or 100mm European type back boxes.Two wire appliance wiring shall be capable of directly connecting to the mounting base.Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel(FACP).The mounting base shall be the same base among all horn, strobe,horn strobe,wall and ceiling models.All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24" H x 4.58"W x 2.19" D. Series HN wall shall measure 5.24" H x 4.58"W x 1.6" D. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68"x 2.63" D.Series HNC ceiling shall have a diameter of 6.68"x 1.50" D. When synchronization is required,the appliance shall be compatible with Wheelock's DSM Sync Modules,Wheelock Power Supplies or other manufacturer's panels with built-in Wheelock Patented Sync Protocol.The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate,the strobe shall revert to a non-synchronized flash-rate and still maintain(1)flash per second over its Regulated Voltage Range.The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock synchronization protocol. Wall Appliances: UL Standard 1971, UL Standard 464,California State Fire Marshal(CSFM), ULC, FM, RoHS Ceiling Appliances:UL Standard 1971, UL Standard 464,California State Fire Marshal(CSFM), ULC, FM, RoHS Note:Due to continuous development of our products,specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc.,dba Cooper Notification standard terms and conditions. EtttliMEMI WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Eaton 1000 Eaton Boulevard Cleveland,OH 44122 United States Eaton.com Eaton Cooper Notification 273 Branchport Ave. Long Branch,NJ 07740 CooperNotif ication.com ®2014 Eaton All Rights Reserved Eaton is a registered trademark. E��• Publication No.TD001017EN All other trademarks are property Powering Business Worldwide October 2014 of their respective owners. 4, ke5\ , S keis.) ivi R 1 �L LISTED ED . .-; M R2 „10:03..4 .1►,b_ "." * MR-100 & MR-200 Series Relays " - - : . The MR Series Multi-voltage Control Relays offer SPDT � ., 1011)) or DPDT 10 Amp resistive contacts which may be operated by one of four input control voltages. A single relay may be energized from a voltage source of 24VDC, 24VAC, 120VAC or 230VAC by wiring to appropriate input terminals. Each relay position contains a red LED which indicates the relay coil is energized. Relays may be "snapped Standard Features: apart" from a standard 4 module assembly and used • Relays may be energized from a voltage independently. These devices are ideal for applications source of 18 to 35VDC or VAC, 120VAC where local contacts are required for system status, or 230VAC remote contacts for control of electrical loads and • Each relay position contains a red general purpose switching. They are suitable for use with LED, which illuminates when the coil is energized. HVAC, temperature control, fire alarm, security, energy • Single, dual or triple relay modules management and lighting control systems. may be "snapped apart"from standard SPDT CONTACTS DPDT CONTACTS 4-position master 10A RESISTIVE@ 10A RESISTIVE@ • DC input is polarized 1120I 1 1 l• • Continuous duty use 1 I. NC C NO •' rNC°NO NC C�•1 0 0 ® 1 1 000000 • Available in dust resistant enclosures with RELAY 1 I I I RELAYENERGIZED I ENELEDIZEO ' ' ENERGIZED LED viewing port 1 1 LED ~ 1 I I 1 • /C versions mounted in enclosures 1 0 1 1 0 0 0 • /C/R versions with red covers for NYC INPUT 0 0 0 0 ; INPUT I 0 0 0 0 and other uses CONTROL I• •INN t15 x••, CON TR 1• 0 1644115 255•, VOLTAGE IIII VOLTAGE • /T versions come complete with track 24(18as)voc—►®®oZ� 24haas)vDc—►®®mo 24(18-32)VAC-►I 230,,0 24VAC--0.MM a mounting hardware which facilitates 120VACyD Dom, 120VAC_0.Ch CI1_, 230VAC1 H Mal 230VAC-P©-40213 installation in standard cabinets TERMINAL STRIP CONECTIONS TERMINAL STRIP CONECTIONS • UL recognized relays rated at 10,000,000 MR-101 MR-201 mechanical operations (MR-104) (MR-204) • UL listed as Control Unit Accessory 015 r rrrria ñiINGS Ail cAra ��� ISO 9001 Space Age Electronics, inc. NFPA Made In U.S.A. REGISTERED www.1SAE.com su -.. 1723 - Uses UL Recognized Components COMPANY085 .48 . Toll Free 508.4855.00966966 Local 508.485.4740 Fax Space Age Electronics, Inc. 2008 ED0313 LT10278 Rev.B 1/2 No Excuses, .lust Solutions! SPACEAGE illiELECTRONICS, INC. PRODUCT SPECIFICATIONS CONTACT TRACK ENCLOSURE UL* MEA CSFM MODEL MODULE CONFIGURATION MOUNTED MOUNTED COVER FILE FILE FILE NUMBER: POSITIONS PER POSITION H X W X D H X W X D MATERIAL S3403 73-92-E 7300-1004 3.25"(82mm) SSU-MR-101/T 1 SPDT 2.125"(54mm) UOXX2 :106 1.50"(38mm) Grey SSU-MR-101/C 1 SPDTABS-94VO UOXX Vol.14 5.125"(130mm) 3.125"(79mm) Plastic UOXX2 :101 2.50"(63mm) Red UOXX7 Vol.22 SSU-MR-101/C/R 1 SPDT ABS-94V0 Plastic SSU-MR-104/T 4 SPDT • :106 Plated SSU-MR-104/C 4 SPDT5.125"(130mm) 18ga UOXX 9.50"(241mm) CRS UOXX2 Vol.14 :101 2.50"(63mm) Red UOXX7 SSU-MR-104/C/R 4 SPDT 18ga CRS 3.25"(82mm) SSU-MR-201/T 1 DPDT 2.125"(54mm) UOXX2 :106 1.50"(38mm) Grey SSU-MR-201/C 1 DPDTABS-94VO UOXX Vol.16 5.125"(130mm) 3.125"(79mm) Plastic UOXX2 :101 2.50"(63mm) Red UOXX7 Vol.22 SSU-MR-201/C/R 1 DPDT ABS-94V0 Plastic 3.25"(82mm) SSU-MR-204/T 4 DPDT 8.5"(215mm) UOXX2 :106 1.50"(38mm) Plated SSU-MR-204/C 4 DPDT5,125"(130mm) 18ga UOXX 9.50"(241mm) CRS UOXX2 Vol.16 :101 2.50"(63mm) Red UOXX7 SSU-MR-204/C/R 4 DPDT 18ga CRS COIL VOLTAGE: MR-100:24(18-35)VDC,24(18-35)VAC,120VAC,230VAC MR-200:24(18-35)VDC,24VAC,120VAC,230VAC (Pull In voltage:75%of nominal max.@ 25°C;Drop out voltage:25%of nominal min.@ 25°C) POLARIZED: DC input only ENERGIZED LED INDICATOR: One per module position CURRENT REQUIREMENT: Per module position:MR-100 Series=18mA/ MR-200 Series=40mA CONTACT RATINGS: 7A @ 28VDC/10A(NO:1/6HP,NC:1/8HP)©120VAC I 7A @ 230VAC CONTACT CONSTRUCTION: Dry Form"C" ENVIRONMENTAL: 32°F to 120°F(0°C to 49°C)@ 85%RH(@ 32°F),Non-condensing,Non-freezing WIRING: Solid or stranded;#12 to#22 AWG terminals /T VERSIONS: 3.5"wide,low profile plastic snap track provided with mounting screws /C VERSIONS: Backbox:18ga CRS,plated with 1/2"conduit knockouts top and bottom AoRA� *UOXX=Control Unit Accessories,System;2=Component;7=Certified for Canada GSpace Age Electronics, inc. www.1SAE.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax This document is subject to change without notice,see doc#ED0479 for legal disclaimer No Excuses, Just Solutions! ED0313 LT10278 Rev.B 2/2 N CO I- I FAPS-A2 SIEMENS BATTERY&VOLTAGE DROP CALCULATIONS FIRE ALARM SUBMITTAL Washington Square FAPS-A2 SPECIFICATIONS FAPS-A2 BATTERY CALCULATIONS FAPS-A2 PANEL 24 Hours(A)Requirement for Standby Charge: PS-8 MODEL 15 Minutes(B)Requirement for Alarn Charge: 15%Design Voltage Drop(20%Max Voltage Drop) 20%(C)Spare Battery Capacity: 3.00 Amp Max Current Draw Per Output 0.13 Amp(F)Standby Total Current Draw 2.50 Amp Max Current Draw Per AUX Output 2.01 Amp(G)Alarm Total Current Draw 8.00 Amp Max Current Draw Per Panel 3.1 Amp Hr(H)Design Standby Charge=(A x F) 14 AWG Wire Gauge 0.5 Amp Hr(J)Design Alarm Charge=(B x G)I60 20A VDC Voltage at First Device' 0.7 Amp Hr(K)Additional Capacity Charge=(C x((A x F)+(B x G)160)) 0.13 Amp Standby Current Draw 4.3 Amp Hr(AH)Battery Amp Hour requirement=(H+J+K) 0.13 Amp Alum,Current Draw 7.0 Amp Hr Battery Size 32.0 Amp Hr Max Battery Charging Capacity FAPS-A2 VOLTAGE DROP CALCULATION RESULTS PERCENT STANDBY ALARM PERCENT OUTPUT VOLTAGE CURRENT CURRENT CURRENT LABEL VOLTAGE DROP DROP DRAW DRAW DRAW OUTPUT-1 NA2-1- 0.53 Volt 2.58% 0.00 Amp 0.53 Amp 17.80% OUTPUT-2 NA2-2- 2.01 Volt 9.85% 0.00 Amp 0.88 Amp 29.30% OUTPUT-3 NA2-3- 0.87 Volt 4.26% 0.00 Amp 0.46 Amp 15.47% OUTPUT-4 NA2-4- 0.00 Volt 0.00% 0.00 Amp 0.00 Amp 0.00% AUX OUTPUT NA2-AX- 0.00 Volt 0.68% 0.00 Amp 0.00 Amp 0.00% Total Current Draw 0.00 Amp 1.88 Amp 23.46% FAPS-A2 VOLTAGE DROP CALCULATIONS OUTPUT-1 LABEL CD MODEL STANDBY ALARM DISTANCE VOLTAGE' Alarm Voltage Drop=VD=R x la FAPS-A2 _ _ `20.400 157.00 Ft (L(Total Circuit Length(One Leg) NA2-1-01 30cd E601-1-24MCC-FW 0.105 28.42 ft 20.397 3.14 Ohm Wire Resistance Per 1000 Feet NA2-1-02 30cd E60H-24MCC-FW 0.105 39.08 ft 20.324 0.99 Ohm (R)Total Circuit Resistance(Both Legs) NA2-1-03 15cd STW 0.057 17.50 ft 20.279 0.00 Amp (Is)Total Current Draw(Standby) NA2-1-04 15cd STW 0.057 14.67 ft 20.264 0.53 Amp (la)Total Current Draw(Alarm) NA2-1-05 30cd E60H-24MCC-FW 0.105 21.33 ft 20.240 19.87 Volt (20.4-(la x R))Applied Voltage at Last Device' NA2-1-06 30cd E60H-24MCC-FW 0.105 36.00 ft 20.180 0.53 Volt (VD)Voltage Drop 2.58% Percent Voltage Drop 17.80% Percent Current Draw Output-1 OUTPUT-2 LABEL CD MODEL STANDBY ALARM DISTANCE VOLTAGE' Voltage Drop=VD=L'R'la FAPS-A23 PS-8 x � 'i i, o -k-"- `28 400 364.17 Ft (L)Total Circuit Length(One Leg) NA2-2-01 15cd E60H-24MCC-FW 0.065 77.83 ft 20.392 3.14 Ohm Wire Resistance Per 1000 Feet NA2-2-02 15cd E601I-24MCC-FW 0.065 40.00 ft 20.305 2.29 Ohm (R)Total Circuit Resistance(Both Legs) NA2-2-03 95cd E60H-24MCC-FW 0.249 92.25 ft 20.068 0.00 Amp (Is)Total Current Draw(Standby) NA2-2-04 75cd E60H-24MCC-FW 0.189 51.42 ft 19.706 0.88 Amp (la)Total Current Draw(Alarm) NA2-2-05 15cd E60H-24MCC-FW 0.065 44.25 ft 19.573 18.39 Volt (20.4-(lax R))Applied Voltage at Last Device' NA2-2-06 75cd E60H-24MCC-FW 0.189 34.83 ft 19.466 2.01 Volt (VD)Voltage Drop NA2-2-07 15cd STW 0.057 23.58 ft 19.394 9.85% Percent Voltage Drop _ 29.30% Percent Current Draw Output-2 AINSIMISTIMININIMINNIIIIMI 1115/2019 PROPRIETARY DOCUMENT FOR APPROVAL ONLY FAPS-A2 VOLTAGE DROP CALCULATIONS CONTINUED OUTPUT-3 LABEL CD MODEL STANDBY ALARM DISTANCE VOLTAGE Voltage Drop=VD=L*R'la FAPS-A2 � '',`,� 'PS-13 2 20.400 298.33 Ft (L)Total Circuit Length(One Leg) NA2-3-01 15cd STW 0.057 177.58 ft 20.391 3.14 Ohm Wire Resistance Per 1000 Feet 14A2-3-02 30cd E50H-24MCW-FW 0.092 6.42 ft 20.230 1.87 Ohm (R)Total Circuit Resistance(Both Legs) NA2-3-03 30cd E60H-24MCC-FW 0.105 42.58 ft 20.184 0.00 Amp (Is)Total Current Draw(Standby) NA2-3-04 30cd E60H-24MCC-FW 0.105 42.67 ft 20.088 0.46 Amp (la)Total Current Draw(Alarm) NA2-3-05 30cd E60H-24MCC-FW 0.105 29.08 ft 20.009 19.53 Volt (20.4-(la x R))Applied Voltage at Last Device' 0.87 Volt (VD)Voltage Drop 4.26% Percent Voltage Drop 15.47% Percent Current Draw Outputs OUTPUT-4 . .,.� .... ,. ,.._.. .. LABEL CD MODEL STANDBY ALARM DISTANCE VOLTAGE Voltage Drop=VD=L•R'la FAPS-A2 - PS-8 - ;3 0 5�jj 20.400 0.00 Ft (L)Total Circuit Length(One Leg) 3.14 Ohm Wire Resistance Per 1000 Feet 0.00 Ohm (R)Total Circuit Resistance(Both Legs) 0.00 Amp (Is)Total Current Draw(Standby) 0.00 Amp (la)Total Current Draw(Alarm) 20.40 Volt (20.4-(la x RI)Applied Voltage at Last Device 0.00 Volt (VD)Voltage Drop 0.00% Percent Voltage Drop 0.00% Percent Current Draw Output-4 AUX OUTPUT LABEL CD MODEL STANDBY ALARM DISTANCE VOLTAGE Voltage Drop=VD=L•R•la FAPS-A2 PS- - --€1;t .a'20.400 0.00 Ft 8 �,- _ (L)Total Circuit Length(One Leg) 3.14 Ohm Wire Resistance Per 1000 Feet 0.00 Ohm (R)Total Circuit Resistance(Both Legs) 0.00 Amp (Is)Total Current Draw(Standby) 0.00 Amp (la)Total Current Draw(Alarm) 20.40 Volt (20.4-(la x R))Applied Voltage at Last Device 0.00 Volt (VD)Voltage Drop 0.00% Percent Voltage Drop 0.00% Percent Current Draw Aux Output Note-1;24 Volt derated by 15%to 20.4 Volts. Note-2;Point to Point Voltage Drop Calculation. Note-3,Line Voltage Drop Calculation PROPRIETARY DOCUMENT FOR APPROVAL ONLY 1/1512019 db LOSS CALCULATIONS SIEMENS FIRE ALARM SUBMITTAL Washington Square Morphe FAAB-A2 PANEL EBA2001 AMP MODEL 0.50 dB Max dB Loss 50 Watt Max Wattage Per Output 100 Watt Max Wattage Per Card 16 AWG Wire Gauge 70 VRMS N1 Audio Voltage db LOSS CALCULATION RESULTS PERCENT OUTPUT db LOSS TOTAL OUTPUT LABEL WATTS LOAD OUTPUT 1 SA2-1- -0.05 dB 3.25 Watts 6.50% OUTPUT2 SAPRE #DIV/0! 0.00 Watts 0.00% OUTPUT 3 SPARE #DIV/01 0.00 Watts 0.00% OUTPUT4 SPARE #DIV/01 0.00 Watts 0.00% Total Watts 3.25 Watts 3.25% OUTPUT 1 db LOSS CALCULATIONS LABEL WATT MODEL db LOSS db L ss 201og10(RL/(RL RW)) FAAB-Fl _ EBA2001 ' � - :_,1 rr'€„�-5- SA2-1-01 114W E60H-24MCC-FW .003 dB 70 VR MS (V)Audio Voltage SA2-1-02 1/4W E60H-24MCC-FW .005 dB 0.0031 Ohm (R)Wire Resistance Per Foot SA2-1-03 1/2W E604-24MCC-FW .012 dB 1,495.42 Ft (L)Total Circuit Length(One Leg) SA2-1-04 1/2W E60H-24MCC-FW .019 dB 1507.69 (RL)Load Resistance=V"251 5A2-1-05 1/4W E601-1-24MCC-FW .022 dB 9.27 Ohm (RW)Circuit Resistance=R*L*2(Both Legs) SA2-1-06 1/4W E60H-24MCC-FW .026 dB 3.25 Watt (W)Total Circuit Wattage 5A2-1-07 1/2W E50H-24MCW-FW .037 dB Total Circuit Signal Loss -0.05 dB 5A2-1-08 1/4W 060H-24MCC-FW .041 dB dB Loss=201og10(RL/(RL.RW)) SA2-1-09 1/4W E604-24MCC-FW .046 dB 6.50% Percent Output Load SA2-1-10 1/4W E66H-24MCC-FW .051 dB PROPRIETARY DOCUMENT FOR APPROVAL ONLY 1/17/2019