Loading...
Permit (142) CITY OF TIGARD MASTER PERMIT • 0, Permit#: MST2018-00348 COMMUNITY DEVELOPMENT 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 12/20/2018 T[GARD Parcel: 2S112BB03200 Jurisdiction: Tigard Site address: 8550 SW COLONY CREEK CT Subdivision: COLONY CREEK ESTATES Lot: 28 Project: Donaldson Project Description: 520 sq. ft. accessory building. BUILDING Floor Areas Required Setbacks Required Stories: Bedrooms: First: sf Basement: sf Left: 5 Parking Spaces: Height: Bathrooms: Second: sf Garage: sf Front: Smoke Dwelling Units: Third: sf Right: 5 Detectors: Total: sf Value: $25,095.00 Rear: 15 PLUMBING Sinks: Water Closets: Washing Mach: Laundry Trays: Rain Drain: Urinals: Lavatories: Dishwashers: Floor Drains: Sewer Lines: SF Rain Storm Sewer: Tubs/Showers: Garbage Disp: Water Heaters: Water Lines: Drains: Catch Basins: Bckflw Prevntr: Footing Drain: Ice Maker: Hose Bib: Backwater Value: Other Fixtures: Drywell-Trench Drain: Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: Clothes Dryers: Heat Pump: N Hoods: Other Units: Furn<100K: Vents: Woodstoves: Gas Outlets: Furn>=100K: ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0-200 amp: 0-200 amp: W/Svc or Fdr: Ea add'I 500 sf: 201-400 amp: 201-400 amp: W/O Svc/Fdr: Mfd Home/Feeder/Svc: 401-600 amp: 401-600 amp: 601-1000 amp: 601+amp-1000v: 1000+amp/volt: ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: N BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ACS SF VB R-3 Owner: Contractor: DONALDSON,JEFFREY D&KARI LEE OWNER Required Items and Reports(Conditions) 8550 SW COLONY CREEK CT JEFF DONALDSON 1 Ersn Cntrl 503-639-4175 TIGARD,OR 97224 8550 SW COLONCY CK CT TIGARD,OR 97224 PHONE: PHONE: 971-404-7220 FAX: Total Fees: $1,034.60 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through 0 952-001-0090. You ii- •• - opy of the rules or• ect questions to OUNC by calling 503.232.1987 . 'B .332. 44. Issued By: ,�j Permittee ig . •re: L�////,,/ Cal 4w '.4175 by 7:00 a.m.for the next available inspection dale. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application Residential RECD roi of MI. I sl: 011.1 City of Tigard rg Received /�j 111 al 13125 SW Hall Blvd.,Tigard,OR 97223 DEC 1 d 2018 Plan tRevie�" �� �� e��� �¢��`� 3�� I Phone: 503.718.2439 Fax: 503.598.1960 Date/By: )2-/i9) ' • £ �JPY tJ -UO3,,As--- Tic;A 1 D Inspection Line: 503.639.4175 CITY OF TIGARD D Date Ready/By: / Tuns: See Page 2 for Internet: www.tigard-or.gov BUILDING DTVI IO I otified/Methodi / �( / / Supplemental Information //AA .. 4 / TYPE OF WORK ' QIRED DATA:I-AND 2-FAMILY DWELLING ,New construction 0 Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all 0 Addition/alteration/replacement 0 Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. 7 c p�c 0 1-and 2-family dwelling 0 Commercial/industrial Valuation: $ ❑Accessory building ❑Multi-family Number of bedrooms: 0 Master builder 0 Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address: S S5o S W C O t an 4 C.X. c_-'—• New dwelling area: square feet City/State/ZIP: -j-l`9 and +()g_ 012..2s+ Garage/carport area: square feet Suite/bldg./apt.no.: Project name: A C.tesso $Adding Z Covered porch area: square feet Cross street/directions to job site: F-4,nn O C.K. pf2U,e. .to COtont1 Cit cr Deck area: square feet Other structure area: 52,..;-- square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: I Lot no.: Permit fees*are based on the value of the work performed. Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. C - F)(A1 ^ -- 3rocl �._ •15x35 Valuation: $ V 52.5 D Existing building area: square feet New building area: square feet (t PROPERTY OWNER _(� 0 TENANT Number of stories: Name: crse.(4- Don dlsc,e Type of construction: Address: 8 550 &ii.J C O I onCie C_r Occupancy groups: "r City/State/ZIP: 19Q Z O 0147 Z-I .. Existing: Phone:(91-1) L-10-1.4. -r 2 2-o Fax:( ) �Or4€ New: 0 APPLICANT ljg.CONTACT PERSON BUILDING PERMIT FEES* (Please refer to fee schedule) Business name: Contact name: Donaldson Structural plan review fee(or deposit): FLS plan review fee(if applicable): Address: latarnSL _ _ Total fees due upon application: City/State/ZIP: Amount received: Phone:( ) Fax::( ) E-mail: PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* CONTRACTOR Commercial and residential prescriptive installation of roof-top mounted PhotoVoltaic Solar Panel System. Business name: p N UGcJ�r✓ Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address: Solar Installation Specialty Code checklist. City/State/ZIP: Permit Fee(includes plan review $180.00 and administrative fees): Phone:( ) Fax:( ) State surcharge(12%of permit fee): $21.60 CCB lic.: n Total fee due upon application: $201.60 Authorized signature: At 6 ,,i..4_._._ This permit application expires if a permit is not obtained �V/ within 180 days after it has been accepted as complete. *Fee methodology set by Tri-County Building Industry Print name: .,{)k) �CN� S n^ Date: �' _ Service Board. I:\Building\Permits\BUP-RESPennitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB) Building Permit Application Checklist One- and Two-Family Dwelling FOR 0141(I. 1SF Ovl.l Received City of Tigard Date/By:Received Permit No.: iiii13125 SW Hall Blvd.,Tigard,OR 97223 = Phone: 503.718.2439 Fax: 503.598.1960 Associated permits: TIGARD 24-Hour Inspection Line: 503.639.4175 ❑ Electrical ❑ Plumbing ❑ Mechanical Internet: www.tigard-or.gov ❑ Other: THE FOLLOWING ITEMS ARE REQUIRED FOR PLAN REVIEW Nes NO yi,k 1 Land use actions completed. See jurisdiction criteria for concurrent reviews. ❑ s is 2 Zoning. Flood plain,solar balance points,seismic soils designation,historic district,etc. ❑ ❑ ❑ 3 Verification of approved plat/lot. 0 0 0 4 Fire district approval required. Name of district: • 0 0 0 5 Septic system permit or authorization for remodel. Existing system capacity ❑ 0 0 6 Sewer permit. 0 0 0 7 Water district approval. 0 0 0 8 Soils report. Must carry original applicable stamp and signature on file or with application. 0 0 0 9 Erosion control 0 plan 0 permit required. Include drainage-way protection,silt fence design and location of catch- 0 0 0 basin protection,etc. 10 3 Complete sets of legible plans. Must be drawn to scale,showing conformance to applicable local and state 0 0 0 building codes. Lateral design details and connections must be incorporated into the plans or on a separate full-size sheet attached to the plans with cross references between plan location and details. Plan review cannot be completed if copyright violations exist. 11 Site/plot plan drawn to scale. The plan must show lot and building setback dimensions;property corner elevations(if 0 0 ❑ there is more than a 4-ft.elevation differential,plan must show contour lines at 2-ft.intervals);location of easements and driveway;footprint of structure(including decks);location of wells/septic systems;utility locations;direction indicator;lot area;building coverage area;percentage of coverage;impervious area;existing structures on site;and surface drainage. 12 Foundation plan. Show dimensions,anchor bolts,any hold-downs and reinforcing pads,connection details,vent size 0 0 0 and location. 13 Floor plans. Show all dimensions,room identification,window size,location of smoke detectors,water heater, 0 0 0 furnace,ventilation fans,plumbing fixtures,balconies and decks 30 inches above grade,etc. 14 Cross section(s)and details. Show all framing-member sizes and spacing such as floor beams,headers,joists,sub- ❑ 0 0 floor,wall construction,roof construction. More than one cross section may be required to clearly portray construction. Show details of all wall and roof sheathing,roofing,roof slope,ceiling height,siding material,footings and foundation,stairs,fireplace construction,thermal insulation,etc. 15 Elevation views. Provide elevations for new construction;minimum of two elevations for additions and remodels. 0 0 0 Exterior elevations must reflect the actual grade if the change in grade is greater than four foot at building envelope. Full-size sheet addendums showing foundation elevations with cross references are acceptable. 16 Wall bracing(prescriptive path)and/or lateral analysis plans. Must indicate details and locations;for non- 0 0 0 prescriptive path analysis provide specifications and calculations to engineering standards. 17 Floor/roof framing. Provide plans for all floors/roof assemblies,indicating member sizing,spacing,and bearing 0 0 0 locations. Show attic ventilation. 18 Basement and retaining walls. Provide cross sections and details showing placement of rebar. For engineered 0 0 0 systems,see item 22,"Engineer's calculations." 19 Beam calculations. Provide two sets of calculations using current code design values for all beams and multiple joists 0 0 0 over 10 feet long and/or any beam/joist carrying a non-uniform load. 20 Manufactured fl—oortroof truss design details. — 0 0 0 21 Energy Code compliance. Identify the prescriptive path or provide calculations. A gas-piping schematic is required 0 0 0 for four or more appliances. 22 Engineer's calculations. When required or provided,(i.e.,shear wall,roof truss)shall be stamped by an engineer or 0 0 0 architect licensed in Ore on and shall be shown to be a licable to the ro'ect under review. 23 Three(3)site plans are required for Item 11 above. Site plans must be 8-1/2"x 11"or 11"x 17". 0 0 24 Two(2)sets each are required for Items 16, 19,20 and 22 above. 0 0 0 25 Building plans shall not contain red lines or tape-ons. "Mirrored"building plans will not be accepted. 0 0 0 26 "Reversed"building plans must meet criteria outlined in the Permit&System Development Fees document. 0 0 0 27 "Drawn to scale"indicates standard architect or engineer scale. 0 0 0 28 Site plan to include tree size,type and location per approved project street tree plan(if applicable),and City of Tigard 0 0 0 Street Tree List. 29 Site plan to include trees and tree protection measures as required by conditions of approval. Tree locations,driplines, 0 0 0 and protection measures must be drawn to scale and must include the project arborist's signature of approval. 30 A Clean Water Services'Sensitive Area Pre-Screening Site Assessment form is required for all building additions, 0 0 0 including decks,patio covers(over non-impervious surface)and accessory structures to existing residential dwellings on a lot of record approved prior to September 9,1995. I:\Buildtng\Pennits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB) City of Tigard .114 ~ COMMUNITY DEVELOPMENT DEPARTMENT T 1 c nt n Building Permit Review — Residential Building Permit #: // ,57 :2,0( F=0O 3L_ __E-- Site Address: 35.GD SvV C.o(onK1 Gree- C Project Name: DOVIAIdSvr1 &C-cesS':,,11 Sj-'t-ttc„ Lot #: (New dwelling=subdivision name;Addition or Alteration=last name of owner) Planning Review Proposal: :.31 .)( Is' 0(6,sSc)►vj STfl(c 1XVerify site address/suite# exists and active in permit system. 1CRiver Terrace Neighborhood: 3K No ❑ Yes,See River Terrace Review Addendum Attached Site Plan Elements: 'hree(3)copies of site plan ,Zraisting structures on site .Site plan must be on 8-1/2"x 11"or 11 x 17"paper j5kcootprint of new structure(including decks)with finished Drawn to scale(standard architect or engineer scale) floor elevations ,North arrow ›itCtility locations&easements(required for new and additions) $ite address,project or subdivision name and lot number idewalk/driveway approach pplicant information(name and phone number) '"rT #cation of wells/septic systems !A' •t dimensions and building setback dimensions NOExisting trees to be retained with drip line,and tree Square footage of buildings to be demolished protection measures 1Xfof area,building coverage area,percentage of coverage and /14:treet tree size,type and location impervious area(applicable if R-7,R-12,R-25&R-40) .S`reet names Property corner elevations(2 foot contour lines if more than >1,000 sf of impervious area created or replaced? No 4 foot differential) If yes,is a storm water quality facility shown? s No e45c Clean Water Services—Service Provider Letter(lot platted prior to 9/10/1995): Required: 'Yes,applicant was notified ❑ No Received: ❑ Yes XNo 7`Public Facilities Improvement(PFI) Permit: Required: ❑ Yes,applicant was notified V No Applied For: ❑ Yes ❑ No,stop intake O, Land Use Case#: KA' V4 Zoning: R-1 L,p n Required Setbacks: Front tiz Rear 5 Side 1 Street Side —1 Garage/�J Landscape Requirement: Vo '6, Lot Coverage Maximum: it O Building Height: Maximum Height ),`� Actual Height !r f t Visual Clearance02 P( No Lands: ❑ Yes ,Ia No Type Urban Forestry Plan PIA-Conditions "Met"prior to issuance of building permit Notes: [Approved By Planning: �3 Date: 12( I.7/1g Revisions (after Building Submittal ot1/1,1 Reviewer Date Revision 1: ❑ Approved ❑ Not Approved Revision 2: El Approved ❑ Not Approved Revision 3: ❑ Approved ❑ Not Approved I:\Building\Forms\BldgPermitRvw RES 061417.docx Building Permit Submittal ) Original Submittal Date: / / f? Xr Site Plans: # Building Plans: # Building Permit#: nter building permit#above. Workflow Routing: Tanning Engineering 'ermit Coordinator uilding Workflow Sign-off: 'Sign-off for Planning(include notes from planning review) Route Application Documents: p.Engineering: (1) copy of permit application, (1) site plan, (1) building plan and original plan review routing form. [iilding: original permit application,site plans,building plans,engineer and beam calculations and trust details,if applicable,etc. Notes: 4By Permit Technician: / ' 6 Date: /I.,70 � ,x �_ � n_, ... �< ,_ �� . �.��� a . ,F,.�, Engineering Review • Slope at building pad: ' m6 Conditions"Met"prior to issuance of building permit M'Easements (encroachments)per engineering conditions of approval and plat lie Water Quality/Quantity Facility: Assess Water Quality Fee in-lieu: ❑ Yes No Assess Water Quantity Fee in-lieu: ❑ Yes No Di/Final / LIDA Facility on lot: ❑ Yes No Di Final Plat Recorded: ❑ NOT Approved by Engineering: Date: Notes: L7 Approved by Engineering: a _, Date: I Z- 18 -18 Revisions (after Building Submittal only) Reviewer Date Revision 1: ❑ Approved ❑ Not Approved Revision 2: 0 Approved ❑ Not Approved Revision 3: ❑ Approved ❑ Not Approved Permit Coordinator Review .'Conditions"Met"prior-to--issuance of building-permit LI Approved,NOT Released: Date: Notes: Revisions (after Building Submittal only) Revision Notice 1: Date Sent to Applicant: Revision Notice 2: Date Sent to Applicant: Revision Notice 3: Date Sent to Applicant: SDC Fees Entered: Wash Co Trans Dev Tax: ❑ Yes N/A Tigard Trans SDC: CI N/A Parks SDC: ❑ Yes N/A LIDA 0 Yes N/A OK to Issue Permit APP y roved b Permit Coordinator: ���^ `' Date: t-2i (�it& I:\Building\Forms\BldgPermitRvw_RES 010118.docx City of Tigard Tel: 503.718.2439 Location: Inspection Date: 8550 SW COLONY CREEK CT, TIGARD, OR, 97224 Record Type: Record ID: Residential - Master Permit MST2018-00348 Inspection Type: Inspector: 299 Final inspection David Young Result: PASS - NoCofO Comments: Final building and electrical on separate permit complete. Violation Summary: Inspector Contractor