Loading...
Plans (3) BU P2016 - 00081 ' For: BUILDING CODE INFORMATION: NewTenan uf - u CHAPTER 10 MEANS OF EGRESS �V DANIEL J. 4 USE CONSTRUCTION SQUARE MAX BARNEY GROUP TYPE FEET OCCUPANCY �� MAR � 6 ZQ�� • • TENANT GROSS SQUARE FOOTAGE PER ISG 1002 CI-ye .nd OH / DINING AREA (TABLES AND CHAIRS) �d'UF�'fGARD "��; �4, A2 3-B 1,926 59 CORRIDOR, _ 3:1,'1:6'11 , • �� NG DIVISION ''` 14 STO RE # 213 `��/ GG SHALL PROVIDE AND INSTALL (I) 4"x6" PLAQUE WITH THE ABOVE BACK OF HOUSE/KITGMHEN/MI5G 1,106 SF *RES INFORMATION AT TWO PRIMARY ENTRY AREAS IN THE BUILDING, \AI A S H I N T N ARE TOO TOTAL GROSS 5F FOR OCCUPANT LOAD 1,926 5F S U PROJECT DESCRIPTION: RESTAURANT TENANT BUILD-OUT SEAL OCCUPANT LOAD (CALCULATED) 10140 SW WASHINGTON SQUARE ROAD T 1004.1.1 DINING AREA(TABLES AND CHAIRS) - 820 SF/15 NET = 55 PEOPLE GOVERNING CODES: 05SC 2014 BUILDING CODE, CITY OF TIGARD MUNICIPAL CODE 2012, TI G A R D97223 2014 OREGON PLUMBING SPECIALITY CODE, ANSI 111,1 2001 EDITION CORRIDOR,RESTROOMS , O R AND CURRENT UPDATES. BACK OF HOIUSE/KITGHEN/MISG. 150 SF/200 6R055 = 4 PEOPLE CHAPTER 3 USE AND OCCUPANCY CLASSIFICATION TOTAL 51 PEOPLE =0 '6) m N p PROJECT TEAM: DRAWING INDEX: SYMBOLS: 3031 (111 .1= il LO CHAPTER5 GENERALBUILDINGHEIGHTSANDAREAS _II ■ tD co�_� 1005.1 OTHEREGRESSCOMPONENTS: OCCUPANTS 5x 2 - " T 505 GROUP S CONSTRUCTION TYPE IIIB - ALLOWED = 9,500 5F, I STORY TOTAL INCHES PER OCCUPANT REQUIRED = IT a) O O N 0 CLIENT: SHEET DESCRIPTION NEW DOOR EXISTING COLUMN LINE. T 505.4 REQUIRED SEPARATION BETWEEN USE GROUPS B OR M SHALL BE I HOUR TOTAL INCHES PROVIDED: o •_ *- NO DOOR LETTER IN SPRINKLERED BUILDINGS (72" EXIT DOOR) = b8" CLEAR X 1 EXITS = 65" - O 8 0 0 TOM WHITAKER ITAK E Ror DOOR � CHAPTER 6 TYPES OF CONSTRUCTION (36" EXIT DOOR = 34" CLEAR X 1 EXiT5 = 34"" W + U J N J a IL 0 _ _ 1oz 28955 S. DALMATIAN ROAD GENERAL: CORRESPONDS TO T 601 BUILDING ELEMENT TYPE III C 10 IL.--) -(-2 MULINO, OR 97042 SI.00 TITLE SHEET EXISTING NEN B ■EEEEEEEEEEEEEEI vi O 61.01 SPECIFICATIONS PRIMARY STRUCTURAL FRAME 0 0 o NF N COLLMN LINE. BEARING WALLS 1001.1 ACCESSIBLE MEANS LC THAN EGRESS REQUIRED, NOT LTHAN ONE. WHERE = i REVISION REFERENCE EXTERIOR 1 MORE THAN ONE MEANS 15 REQURIED FROM FROM ANY ACCESSIBLE _INTERIOR 1 SPACE, EACH ACCESSIBLE PORTION OF THE SPACE SHALL BE SERVED L E § rn NONBEARING WALLS AND PARTITIONS EXTERIOR CD A ______ 5�T 602 BY NOT LESS THAN T'WO ACCESSIBLE MEANS OF EGRESS. 0 6 -: 2� ARCHITECT: ARCHITECTURAL: 1 NONBEARING WALLS AND PARTITIONS INTERIOR 12 1005.1.1 MINIMUM WIDTH OF EACH DOOR OPENING - CLEAR WIDTH = 52" . 0 0 o = r FLOOR CONSTRUCTION AND SECONDARY MEMBERS O 1011.1 EXIT SIGNS REQUIRED AT EXITS O E= 0 WALL TYPE 10113 TACTILE "EXIT" SIGN REQUIRED - ADJACENT TO EACH EXIT DISCHARGE m A5.01 SITE PLAN BUILDING,WALL AND DETAIL SECTION MARK INDICATES WALL ROOF CONSTRUCTION AND SECONDARY MEMBERS O - a ■■ ark i nevi cc DI.OI DEMOLITION PLAN INDICATES SECTION ti SING CHAPTER 8 INTERIOR FINISHES 10143 AND COMMON PATH OF EGRESS TRAVEL = 55' 100' ALLOWED 1111 tTSai r AI.OI FLOOR PLAN Na WALL DETAIL. 1028.8 :F-2 > N N N ■ architects + urbanists A1.02 WALL FRAMING PLAN T 503.9 SPRINKLERED EXIT ENCLOSURES CORRIDORS ROOMS AND ■ 2 Architecture•Plennin •Interiors•Preservation•Urbart!)esi r, q AND PASSAGEWAYS ENCLOSED SPACES T 1016.1 EXIT ACCESS TRAVEL DISTANCE WITH SPRINKLER SYSTEM ¢ U co U a iL. Planning 9 AI.03 FLOOR FINISH PLAN A6 0' INDICATES DRAWING INDICATES ADDITIONAL USE Jp A2 A A e A = 250 FT www.Brkirleti cs.COm A1.04 EQUIPMENT PLAN 5HMr WHIUNTY�GAU WALL SECTION IS SHOWN. COMPONENT-SEE WALL CLASS AFLAME SPREAD 0-25;SMOKE-DEVELOPED 0-450 A1.05 RESPONSIBILITY MATRIX DETAIL CLASS B:FLAME SPREAD 26-15;SMOKE-DEVELOPED 0-450 T 1015.1 OCCUPANT LOAD SERVED BY CORRIDOR WITH SPRINKLER SYSTEM CLASS C:FLAME SPREAD 16-200;SMOKE-DEVELOPED 0-450 A - GREATER THAN 30 = 0 HOUR P M.E.P. CONSULTANT: A2.01 REFLECTED CEILING PLAN ENLARGED PLAN OR DETAIL REFERENCE KEYNOTE SYMBOL,LEW FOR DEMO,FLOOR AE.0 CHAPTER 9 FIRE PROTECTION SYSTEMS PROJECT: A2.02 CEILING PLAN DETAILS CEILING 107E5.INDICATES DETAIL 1015.4 DEAD END CORRIDORS = 20 FT MAX W H S ENGINEERING A2.03 SUSPENDED CEILING DETAILS ""� - IFP 01) 906 PORTABLE FIRE EXTINGUISHERS A5 REQUIRED BY IFC T 1021.1 REQUIRED NUMBER OF EXITS BASED FOR OCCUPANT LOAD: ❑ A5.0I INTERIOR ELEVATIONS 2012 WEST 25TH STREET, #512 AND DETAILS AG.04 >< FINISH KEYNOTE 51COL. (59) = I EXIT REQUIRED,2 EXITS PROVIDED Q 1 CLEVELAND, OHIO 44113 \ CHAPTER 11 ACCESSIBILITY 0 216.227.8505 A5.02 INTERIOR ELEVATIONS / (PLAM-0t C AND DETAILS INDICATES DRAWING 1104.1 SITE ARRIVAL POINTS - ACCESSIBILITY PROVIDED O W SHEET ON INF ICH BUILDING OWNER A5.05 EXTERIOR ELEVATIONS PLAN/DETAIL IS SHOE( EQUIPMENT/ACCESSORY KEYNOTE 5YMPOL. 11043.1 EMPLOYEE USE AREAS - ACCESSIBILITY PROVIDED 0 1: A6,01 SCI-IE7ULES AND DETAILS 1105.1 AT LEAST 60% OF PUBLIC ENTRANCES ARE ACCESSIBLE I- Q THE M AC E RIC H COMPANY 1101.2 TOILET FACILITIES, AT LEAST ONE OF EACH TYPE OF FIXTURE AND w m INTERIOR/EXTE>RIOR ELEVATION RANGE AND ACCESSORIES SHALL BE ACCESSIBLE IL 0' N 401 WILSHIRE BLVD, SUITE 700 INDICATES ELEVATION EXISTING: LEVEL LINE_,CONTROL POINT OR DATUM. < [/') N CHAPTER 29 PLUMBING m -,SANTA MONICA, CA 90401-1452 N NUMBER. h MECHANICAL: 244 �Y ' Z Cr 602.953.8344 WALL ELEVATION OREGON PLUMBING SPECIALITY CODE, SEE PLUMBING DRAWINCZ FOR M-I01 MECHANICAL SPECIFICATIONS W �SUB-NO AND FILL MARK TOM (11t) COMPLIANCE � C0 p[ AND DETAILS A6-04 12'-0" ‘114 TABLE 2902.1 USE A OCCUPANT LOAD (BASED ON CALCULATED) = 51 11J z tE 0 NG M-102 MECHANICAL PLAN I�r OWN yIl FIXTURE TYPE OCG /SF NO OF OCG REQUIRED PROVIDED \'‘.t. AND SCHEDULES S ELEVATION IS SORil. 0 d 0 r-r CL NEW: LEVEL LINE,CONTROL POINT OR DATUM. MALE WATER CLOSETS I PER 50 2�I I I ` [./7 Q PLUMBING: EXISTING PARTITION TO REMAIN. Z Q 0P-101 PLUMBING SPECIFICATIONS TOM FEMALE 1 PER 50 30 I ! I I I 1 12'-0" LAYS V) P-102 PLUMBING.PLAN MALE I PER 150 21 I f Q EMS-TINS PARTITION TO BE REMOVED. FEMALE I PER 150 50 I I LA C - CONTRACT LIMIT LINE DRINKING FOUNTAIN I PER 500 5q I NA CI SERVICE SINK -- -- 1 1 r-I ELECTRICAL: war PARTITION,SEE SCHEDULE. - - - - URINALS -- -- -- -_ O E-I01 Fl FGTRIGAL Ci'CGIFIGATIONS I I HIGH 'SEE PLANS FLOOR.LINE,PROPERTY LINE. 2102.2 WHERE PLUMBING FIXTURES ARE REQUIRED,SEPARATE FACILITIES 1 E-102 LIGHTING PLAN 1 I LOW HALL,SEE PLANS SHALL BE PROVIDED FOR EACH SEX. E-I03 POWER It COMMUNICATIONS PLAN - - 21032 A DRINKING FOUNTAIN NEED NOT BE PROVIDED IN A DRINKING OR EXCEPTION DINING ESTABLISHMENT ROOM NUMBER ITEMS ABOVE,BEYOND,OR NOT IN CONTRACT 01.1.C.). 410.1 OPSC WHERE WATER 15 SERVED IN RESTAURANTS,OR WHERE BOTTLED ___---INDICATES ROOM WATER COOLERS ARE PROVIDED IN OTHER OCCUPANCIES, DRINKING OFFICE _ _ _ _ _ _NAME. FOUNTAINS SHALL NOT BE REQUIRED. MARK ISSUE: DATE: ( 102 ) Review 50% 01/18/16 -..--------INDICATES ROOM CHAPTER 4 OPSC MINIMUM PLUMBING FACILITIES Review 90% 02/05/16 Property Owner Review 02/23/16 410.1 OPSC WHERE HATER 15 SERVED IN RESTAURANTS,OR WHERE BOTTLED 'Permit Set ` 03/11/16 WATER COOLERS ARE PROVIDED IN OTHER OCCUPANCIES, DRINKING CITY OFTIGARD FOUNTAINS SHALL NOT BE REQUIRED. " . ABBREVIATION LEGEND: GENERAL PROJECT NOTES: LOCATION MAP: °T`� .��� 4.Urn {.r '= Ii AB ANCHOR BOLT GOL COLUMN FL FLOOR ID INSIDE DIAMETER OA OVERALL QT QUARRY TILE SP SUSPENDED H 14117141171-1IIL THE CONTRACT DOCUMENTS ARE PREPARED FOR THE CONTRACTOR TO BECOME FAMILIAR 4 " ai. � A/C AIR GONDITIONIN6 GONG CONCRETE FLUOR FLUORESCENT IN INCH 00 ON CENTER QTY QUANTITY 5V SHEET VINYL W/ WITH WITH THE SCOPE OF WORK AND PROPOSED DESIGN CONCEPT. - ,i� Y� AWLS ACOUSTIG(AU CONN CONNECTION FM FACE OF MASONRY INCL INCLUDE(INCLUSIVE) OCAFF ON CENTER ABOVE FINISH SVNS SEAMLESS VINYL-NON 5UP WO WITHOUT 2. DO NOT SCALE THE CONTRACT DOCUMENTS. DIMENSIONS AS INDICATED SHALL GOVERN. -- - F ACT ACOUSTICAL CEILING TILE CONST CONSTRICTION FR FIRE RESISTANT INSUL INSULATION FLOOR. R RISER 5V5 SEAMLESS VINYL`�T HAI WALL TO WALL 3. CONTRACTORS SHALL WARRANT THEIR RESPECTIVE CONSTRUCTION AND WORK TO ea i. * 1� r f ° 4. r r. Ili. ,. _ ,mii... . al 1.`� 'r• Mr- ' ADJACENT GOVT CONTINUOUS FRP FIBERGLASS REINFORCED INT INTERIOR RA RETURN AIR 5Y5 SYSTEMS WG WATER CLOSET fro.. • N, �. mss► 11%.2:01111...... AFf ABOVE FINISH FLOOR WORD/ COORDINATE PANELS OD OUTSIDE DIAMETER RAD RADIUS WGAR WALL CARPET PERFORMED IN ACCORDANCE WITH THE REQUIREMENTS IF ALL LOCAL,STATE,AND FEDERAL _ "'1 r tlx:. - LAWS AUTHORITIES HAVING. JURISDICTION, AND MAtNUFAGTURER'S INSTALLATION AND ,�.i- r :.a a r ALT ALTERNATE CORR CORRIDOR FRT FIRE-RETARDANT TREATED JAN JANITOR MDR OVERHEAD DOOR RA6 RETURN AIR GRILLE T THREAD WD WOOD +'si ALUM ALUMINUM CPT CARPET FRTYD FIRE-RETARDANT TREATED ..IST JOIST OPH OPPOSITE HAND RD ROOF DRAIN T/6 or TONGUE AND GROOVE WH HATER HEATER WARRANTY REQUIREMENTS. • ' � NI ANOD ANODIZED CS CONCRETE SEALER MOOD OVRD OVERFLOW ROOF DRAIN REG RECEPTACLE? Ti INEYNE3 MOISTER AND MOLD 4. CONTRACTORS SHALL PROVIDE ALL REQUIRED LABOR AND MATERIALS TO ACHIEVE ` R ...�.+. . ...z t i EI T 4. APPROX APPROXIMATE CSLR COURSE FT FEET KD KNOCK DOWN 0/0 OUT TO OUT REF REFRIGERATOR TO TRENCH DRAIN RESISTANT GYPSUM WALL INDUSTRY STANDARD OF MEANS AND METHODS TO ACHIEVE THE DESIGN INTENT OF THE I - 1 .,s.t_tr-476f "i r ARCH ARCHETE OTNRAU CT CERAMIC TILE FIG FOOTING KO KNOCK OUT OPG OPENING REG REGISTER TEL TH.EPHOEE BOARD CONTRACT DOCUMENTS REGARDLESS WHETHER OR NOT DOCUMENTED HEREIN; �' PROJECT#: 15085.01 AUTO AUTOMATIC GTP CERAMIC TILE -PORCELAIN FURR FURRING OPP OPPOSITE REINF REINFORCEMENT TEMP TEMPORARY WIN WINDOW CONSIDERATIONS FOR ADDITIONAL LABOR OR MATERIAL COSTS ON THE BASIS OF OMISSIONS 7 - I CTR CENTER FVC FIRE VALVE CABINET OPT OPTIONAL (REII'FORCIN6) TEMPD TEMPERED WG HIRE GLASS L LENGTH{LONG) SHALL NOT P. GRANTED. :y • .'- # !7 : • '• s DRAWN BY: DN CHECKED BY: DJB EBD BOARD FWG FABRIC WALLGOVE RING REQ') REQUIR O TER TERRAZZO HNT WEIGHT t r = •( ! / is LAM LAMINATE(D) 5. INTERPRETATIONS,CLARIFICATIONS, CHANGES, DELETIONS,AND RELATED MODIFICATIONS TO , . BETH BETT�N D DEPTH PT PAVER TILE RES RESILIENT TEX TEXTURE WIF HEEDED WIRE FABRIC4w *r e. • / �_~ •..;./ Arlcinetics,Inc.and their Coruultams shall be deemed the authors BLDG DEL DOUBLE GA GAUGE LAV LAVATORY PBD PARTICLE BOARD RET RETURN INK THICK THE CONTRACT DOCUMENTS SHALL BE SOLELY BY THE ARCHITECT EITHER BY ISSUANCE OFAe�R BUILDINGLB POUR" # l �. r and owners of their respective Instruments of Service and shall ELK DEG DCGRZad 6ALV 6ALVANEZED PG PRECAST CONCRETE REV THD THRESHOLD YD YARD CONSTRUCTION CHANGE DIRECTIVE OR ARCHITECT'S SUPPLEMENTAL INSTRUCTIONS. .ie Bl OCK(IN6) REVISIT(REVISION) c a•.•-- retain all common law,statutory and other reserved rights,including BLKHD gip Ao DEMO DEMOLITION GG GENERAL CONTRACTOR LF LINEAR FEET(FOOT) PGF POUND5 PER CUBIC FOOT RF RESINOUS FLOORING TOG TOP OF CONCRETE(TOP OF 6. IT IS THE RESPONSIBILITY OF T IlE CONTRACTOR(S) TO VERIFY ALL FIELD CONDITIONS PRIOR .1: p copyrights.The Instruments of Service shall not be used for future LIM LIMITED s F ' r. k n ELM BEAM OF DRINKING FOUNTAIN GL GLASS LT PGM PREFACED CONCRETE RM ROOM CURB) TO SUBMITTING PROJECT BIDS,ORDERING MATERIALS GENERATING SHOP DRAWINGS AND �., additions or alterations to this Project or for other projects without 1307 BOOM DIA DIAMETER GR GRADE LIGHT 'MASONRY RO ROUGH OPENING TOG TOP OF STILL . v . " the prior written agreement of Arkineties,Inc Any unauthorized use LIGHTING SUBMITTALS,AND START OF WORK. THE ARCHITECT SHALL NOT BE HELD LIABLE FOR. - - . -i r of the Instruments of Service shall be at the owners sole risk and BRIDGING DIM DIMENSION GYP EBD GYPSUM BOARD LTG. PERIM PERIMETER WS REVERSE Too TOP OF DECK . , ! SRC-a BEARING DISP DISPERSER GE•EE3 GYPSUM WALL BOARD LVR LOUVER PG BD PEG BOARD TOM TOP OF MASONRY UN-VERIFIED FIELD CONDITIONS. �,- without liability to Arkinetics,Inc.and their Consultants BIRK BRICK ON DOWN PL PLATE SG SOLID CORE TOJ TOP OF JOIST 1. IT 15 THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY TIE ARCHITECT IN iNRITI146 OF • ,*`•-. fi' ..I •? .•- • arkinetics©2016 BSMT Bq ENT DR DOOR H HIGH M'°'� PLAS PLASTIC SCREED 5C+WULE TOP TOP OF PARAPET ANY DISCREPANCIES,DIFFERENCE=S,OR ABNORMALITIES WITH THE FIELD CONDITIONS AGAINST Fa _ - FIR BUILT-UP ROOFING 05 DOM SPour HB HOSE BIBB MASONRY PLAM PLASTIC LAMINATE SD SMOKE DETECTOR TON TOP OF HALL THOSE AS DOCUMENTED IN THE CONSTRUCTION DOCUMENTS IN A TIMELY FASHION. THE "- �` DET DETAIL HG HOLLOW CORE MAT MATERIAL PLBS PLUNGING SPL SADDLE Tr. TYPICAL _•x j DRAWING TITLE: GIG GETTER TO CENTER DWG. ORAWIN6 ROW HARDBOARD MAX MAXIMUM pip PRFNIOIJI DlSD sec' sEGT10N CONTRACTOR.SHALL BE HELD LIABLE FOR FAILURE TO REPORT ITEMS TO THE ARCHITECT F `;b: • a > a CAST GABINEr DWR DRAWER. HExPv HANDICAPPED MEGH MECHANICAL •PNL PANEL sFn- SHEET AND RESPONSIBLE FOR CONSTRUCTION COSTS AND APPLICABLE i"!<C5 TO REMEDY } TITLE SHEET GAD CADMIUM DW DRYWALL HDY.R HARDWARE PNT PAINT SIM SIMILAR UG. ' ME3MB MEMBRANE CONFLICTS. CATCH BASIN ti v MFR MANUFAGTUReR B. NO SUBSTITUTIONS,GRANGES,OR OMIS510N5 FROM THE CONTRACT DOCUMENTS ARE +4 .. .>r �.• _r rr r GBHDWD HARDWOOD PLYI�U PLYWOOD 5LT 51ATE UNPIN UNFINISHED CEM CST E S EXPOSED STEEL HM HOLAW METAL IMM MINIMA POL POLISHED SP STAND PIPE UNUM UNLIMITS] PERMITTED. GONTRAGTOR MAY REQUEST SUBSTITUTIONS,CHANGES, AND/OR OMISSIONS IN ,__ I - , fi =-f * • OFFICE COPY CL or Q CENTER LINE ETR EXISTING TO REMAIN HORIZ HORIZONTAL PR PAIR SPEC SPECIFICATIONS LINO KEGS NOTED OTHERWISE WRITING BY THE ARCHITECT. 1 • - ' • ....w GPM CUBIC FEET PER MINUTE EXIST EXISTING HPC HIGH PERFORMANCE ra MISG MISCELLANEOUS PREFIN PREFINI�D SPKR SPEAKER !JR URINAL 1. CLARIFICATIONS TO THE DOCUMENTS SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT FORMO MASONRY S- r- p•-4.11 r CG CORN9WRINKLIER GUARD COATING r OPENING PREFAB PREFABRICATED SPKLR RINKLIER REVIEW AND RESPONSE. Cl CAST IRON FA FIRE ALARM HPDL HIGH PRESSURE DECORATIVE PROJ PROJECTION SPR SINGLE PLY ROOFING VERT VERTICAL GJ JOINTMIL METAL 10, THE GONTRAGTOR IS RESPONSIBLE FOR THE REVIEW AND COORDINATION OF WORK A5 FS FACE BRICK LAMINATE MILL MULLION I PRE-STRESS CONCRETE SO SQUARE VEST VESTIE3Ul E CONI \U�. I loN S� 6L6 CEILING FCU FAN COIL UNIT HR HOUR PGF POUNDS PER SQUARE FOOT SQ IN SQUARE ENGH VG VINYL,COVE ENTAILED WITHIN THE CONTRACT DOCUMENTS, 1NGLJIDING THOSE OF THE ARCHITECT'S TENANT LOCATION GL CLOSET F/F FACE TO FACE HT HEIGHT PSI POUNDS PE3i SQUARE INCH 5Y SQUARE YARD VCT VINYL COMPOSITE TILE CONSULTANTS. COORDINATION OF RELATED TRADE WORK SHALL INCLUDE BUT NOT BE LIMITED WA NOT APPLICAIBLE CUR CLEAR FD FLOOR DRAIN HT6 HFATIN6 PT POINT 55 STAINLESS STEW VIF VERIFY IN FIELD TO: SEQUENCING,PHASING,FIELD GOOVINATION,CUTS AND OPENINGS, INSPECTIONS,AND CLL CONTRACT LIMIT LINE FDN FOUNDATION HTR HEATERNIC NOT IN CONTRACT PTD PAINTED SLOP SES V5 VINYL STRAIGHT APPROVALS. CITY OF TIGARD SHEET#: NO GNTR COUNTER FE FIRE EXTINGULHER HVAC HEATING,VENTILATION AIR NUMBER EAPTN PARTITION STD STANDARD VWC VINYL kuoicoveRIN6 NOM NOMINAL II. THE CONTRACTOR 15 RESPONSIBLE FOR VERIFYING ALL QUANTITIES PRIOR TO ORDERING A CMT CERAMIC MOSAIC TILE EEC FIRE F_XTINGUISHERCAEBINET CONDITIONING PVC POLYVINYLGFLORDE GTL STEEL Approved by Planning CMU CONCRETE MASONRY UNIT FHC FIRE HOSE CABINET HW HOT WATER NTS NOT TO SCALE PVM'T PAVEMENT STOR STORAGE �T 1 LT- ARCHITECT SHALL NOT BE HELD LIABLE FOR QUANTITIES AS NOTED ON Pp ,31 I o V�� CO CASED OPENING/GLEAN our FIN FINISH HhW HOT WATER HEATE=R STRUC STRLJGTUREB;AUDOCUMENTSDate: NORTH Initials: '�'1 G1 • 00 DIVISION I - GENERAL DATA SECTION 066400-PLASTIC PANELING D.B. LEVELS OF GYPSUM FINISHING PER 6A214-9b: A. GENERAL: GEL-COATED-FINSHED,GLASS-FIBER-REINFORCED PALSTIC PANELS COMPLYING WITH ASTM D D.B.A. LEVEL 0 -UNFINISHED I. SECTION 01000 - CONDITIONS AND REQUIREMENTS 5319. D.B.B. LEVEL I - TOOL MARKS AND RIDGES ACCEPTABLE.TAPE EMBEDDED IN COMPOUND OVER B. MANUFACTURERS: JOINTS AND ANGLES. FREE OF EXCESS COMPOUND - SURFACE.OPTIONAL - ONE COAT OF A. THE CONTRACTOR AND SUB-TRADES ARE RESPONSIBLE FOR THE VERIFICATION OF ALL SITE DIMENSIONS BA. KEMLITE GOMAPNY INC. COMPOUND OVER ACCESSORIES AND FASTENERS. RELATIVE TO THEIR WORK AND SHALL IMMEDIATELY NOTIFY THE ARCHITECT, IN WRITING,OF ANY B.B. MARL ITE DB.C. LEVEL 2 - TOOL MARKS AND RIDGES OKAY.THIN COATING OF COMPOUND COVERS TAPE;ONE DISCREPANCY FOR APPROVAL BEFORE EXECUTING THEIR WORK. B.G. NUDO PRODUCTS, INC. COAT COMPOUND OVER FASTENERS HEADS.TAPE EMBEDDED IN COMPOUND AND IMMEDIATELY B. THE GENERAL CONTRACTOR,(GG),SHALL BE RESPONSIBLE FOR FOLLOWING ALL CITY,STATE,REGIONAL, C. NOMINAL THICKNESS SHALL BE DETERMINED BY ARCHITECT,GC TO VERIFY. WIPED TO LEAVE A THIN COATING OF COMPOUND OVER TAPE - JOINTS AND ANGLES.ONE COAT D. SURFACE FINISH: SHALL BE DETERMINED BY ARCHITECT,GG TO VERIFY. OF COMPOUND - ACCESSORIES AND FASTENERS. FREE OF EXCESS COMPOUND - SURFACE. AND FEDERAL CODES AND REGULATIONS FOR THE ENTIRE CONSTRUCTION OF THE PROJECT. E. TRIM ACCESSORIES: MANUFACTURERS STANDARD ONE-PIECE VINYL EXTRUSIONS DESIGNED TO RETAIN D.B.D. LEVEL 3 - NO MARKS OR RIDGES.READY FOR PRIMING,TO BE FOLLOWED BY HEAVY TEXTURE. C. GC SHALL BE RESPONSIBLE FOR SECURING AND PAYING FOR ALL REQUIRED PERMITS,INSURANCE, AND COVER EDGES OF PANELS.PROVIDE DIVISION BARS, INSIDE CORNERS,OUTSIDE CORNERS AND CAPS ONE SEPARATE COAT OF COMPOUND OVER LEVEL 2 - JOINTS AND ANGLES. TWO SEPARATE PERFORMANCE BONDS, INSPECTIONS,ETC.REQUIRED FOR THE COMPLETION OF THE PROJECT AS REQUIRED AS NEEDED TO CONCEAL EDGES. COATS OF COMPOUND -ACCESSORIES AND FASTENERS. JOINTS FILLED AND SMOOTH.SHALL BE ,, BY THE OWNER AND ALL AUTHORITIES HAVING JURISDICTION OVER THE PREMISES. F. ADHESIVE: AS RECOMMENDED BY PLASTIC PANELING MANUFACTURER. PRIMED BEFORE PAINTING OR TEXTURING - SURFACE. 1.-z ,I', D. 6C SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE(I) YEAR FROM DATE G. SEALANT:MILDEW-RESISTANT SEALANT RECOMMENDED BY PLASTIC PANELING MANUFACTURER AND DB.E. LEVEL 4 -NO MARKS OR RIDGES.READY FOR PRIMING,FOLLOWED BY WALLCOVERINGS,FLAT )" OF FINAL ACCEPTANCE BY THE OWNER,AND AGREES TO MAKE GOOD ALL DEFECTS WITHOUT COST TO THE COMPLYING WITH REQUIREMENTS OF JOINT SEALANTS AND KITCHEN GRADE. PAINTS OR LIGHT TEXTURES. TWO SEPARATE COATS OF COMPOUND OVER LEVEL 2 - JOINTS OWNER IN A REASONABLE LENGTH OF TIME. H. INSTALLATION: AND ANGLES. THREE SEPARATE COATS OF COMPOUND -ACCESSORIES AND FASTENERS. E. THE CONTRACTORS,SUBCONTRACTORS,AND SUB-TRADES SHALL VISIT THE SITE TO INSPECT AND HA. LAYOUT PANELING BEFORE INSTALLING.LOCATE PANEL JOINTS 50 THAT TRIMMED PANELS AT JOINTS FILLED AND SMOOTH AGAIN.SHALL BE PRIMED BEFORE PAINTING OR TEXTURING- }1) FAMILIARIZE THEMSELVES WITH ALL CONDITIONS AFFECTING THE CONSTRUCTION WORK AND THE CORNERS ARE NOT LESS THAN IT WIDE. SURFACE. SUBMISSION OF HI5 BID SHALL BE CONSTRUED AS INDICATION OF SUCH KNOWLEDGE. NO PAYMENT WILL BE HAA. LOCATE TRIM ACCESSORIES TO ALLOW CLEARANCE AT PANEL EDGES ACCORDING TO DB.F. LEVEL 5 - NO MARKS OR RIDGES.ENTIRE SURFACE COVERED WITH SKIM COAT OF COMPOUND MADE DUE TO LACK OF KNOWLEDGE OF EXISTING CONDITIONS. MANUFACTURE'S WRITTEN INSTRUCTIONS. AND READY TO PRIME BEFORE DECORATING WITH GLOSS,SEMIGLOSS OR ENAMEL,OR FLAT F. ALL MATERIALS AND LABOR SHALL BE SUPPLIED BY THE GC AND SUB-TRADES AS HEREIN SPECIFIED,AND HAAA. INSTALL PANELS IN A FULL SPREAD OF ADHESIVE. JOINTS OVER AN UNTEXTURED SURFACE.AS IN LEVEL 4 - JOINTS AND ANGLES. AS IN LEVEL 4 SEAL AS REQUIRED TO COMPLETE AND FINISH ALL CONSTRUCTION AND FINISH WORK. IT IS THE RESPONSIBILITY HAA.B. INSTALL TRIM ACCESSORIES WITH ADHESIVE AND NAILS OR STAPLES. DO NOT FASTEN - ACCESSORIES AND FASTENERS.SKIM COAT PLUS PRIMER BEFORE PAINTING OR TEXTURING- OF THE GC TO COORDINATE A SMOOTH CONSTRUCTION SCHEDULE. THROUGH PANELS. SURFACE. G. GC SHALL MAINTAIN AT THE PROJECT SITE DURING CONSTRUCTION A MINIMUM OF ONE(I)SET OF COMPLETE H.A.B. FILL GROOVES IN TRIM ACCESSORIES WITH SEALANT BEFORE INSTALLING PANELS AND BED AND CURRENT CONSTRUCTION DOCUMENTS AND SHOP DRAWINGS. INSIDE CORNER TRIM IN A BEAD OF SEALANT. E. QUALIFICATIONS: H. GC SHALL SUPPLY AND INSTALL ALL OTHER FINISH MATERIALS NECESSARY TO COMPLETE THIS PROJECT H.A.C. MAINTAIN UNIFORM SPACE BETWEEN PANELS AND WALL FIXTURES.FILL SPACE WITH SEALANT. EA. APPLICATOR: COMPANY SPECIALIZING IN PERFORMING THE WORK OF THIS SECTION WITH MINIMUM WHETHER OR NOT SUCH MATERIALS ARE CALLED OUT ON SCHEDULES AND DRAWINGS,UNLESS NOTED THREE YEARS EXPERIENCE AND APPROVED BY MANUFACTURER. OTHERWISE. DIVISION 8 - DOORS AND WINDOWS F. MANUFACTURERS: I. THE CONTRACTOR AND SUB-TRADES SHALL FROM TIME TO TIME DURING THE CONSTRUCTION AND AT THE FA. U.S.GYPSUM CA COMPLETION OF THE PROJECT,REMOVE ALL EXCESS MATERIALS AND DEBRIS CAUSED BY HIS WORK.HE FAA. OTHER ACCEPTABLE MANUFACTURERS OFFERING EQUIVALENT PRODUCTS. 411) v0 C +' SHALL LEAVE THE SITE IN A VERY CLEAN CONDITION AND SHALL CLEAN ALL SURFACES TO BE FREE FROM I. SECTION 08110 - STEEL DOORS AND FRAMES FA.AA. DOMTAR . N SPATTERS,STAINS,DRIPS,EXCESS GLUE,SEALANTS,CAULKING COMPOUNDS,ETC. F.A.A.B. GOLDBOND O O r J. GC SHALL PATCH AND MATCH ANY AND ALL EXISTING PARTITIONS WHICH HE HAS ALTERED OR CUT TO A. FURNISH STEEL DOORS AND FRAMES AS INDICATED ON THE DRAWINGS. FA.A.C. CELOTEX 0 uo - C") 0 MATCH A5 CLOSELY A5 POSSIBLE IN COLOR AND TEXTURE. EDGES SHALL BE FEATHERED TO AVOID B. COMPLY WITH STEEL DOOR INSTITUTE "RECOMMENDED SPECIFICATIONS FOR STANDARD STEEL DOORS AND F.B. SUBSTITUTIONS:UNDER PROVISIONS OF SECTION 01600. 0 g a) (o (0 LUMPS AND UNEVEN APPEARANCES. FRAMES"(SDI - 100). G. FRAMING MATERIALS: II O 05 -r- K. WORK UNDER THIS CONTRACT INCLUDES,BUT 15 NOT LIMITED TO THE COMPLETE SCOPE OF WORK SHOWN C. GALVANIZED AT EXTERIOR LOCATIONS. GA. METAL STUDS AND TRACKS: ASTM C645;GA2Ib AND GA-600;GALVANIZED SHEET STEEL,25 GAGE ? CV CV) ge NO ci ci ON THE DRAWINGS AND THE PATCHING AND REPAIRING AND FINISHING OF ALL ADJACENT ROOMS WHERE THICK,C SHAPE,WITH KNURLED FACES,UNLESS SHOWN OTHERNISE ON THE DRAWINGS.SIZES ARE AS0 r- .c REMODELING OR MODIFICATIONS TAKE PLACE. II. SECTION 08211 - FLUSH WOOD DOORS INDICATED ON THE DRAWINGS. i r i L. SEQUENCE OF THE WORK G.B. WOOD STUDS AND PLATES: CONSTRUCTION GRADE I;NOM 2 INCH X 4 INCH OR LARGER,SPACED NOT 0 0 > 0 J N J d LL LA. THE CONTRACTOR MAY WORK NORMAL DAYTIME HOURS. CONSTRUCTION DURATION MAY BEA A. FURNISH FLUSH WOOD DOORS AS SHOWN ON THE DRAWINGS. MORE THAN lb INCHES OC. +CONSIDERATION IN THE AWARD OF THE CONTRACT. G.G. SHAFT WALL STUDS: ASTM C645,GA-216 AND GA-600;GALVANIZED SHEET STEEL C-H STUDS,22 C U L.B. TIME RESTRICTIONS FOR PERFORMING WORK REQUIRING SYSTEM SHUTDOWNS MAY OCCUR ONLY WITH B. COMPLY WITH ANI STANDARD SECTION 1300 FOR CUSTOM GRADE SOLID CORE DOORS;WOOD PARTICLEm GAGE THICK,NITH KNURLED FACES,SPACED MAXIMUM OF 24 INCHES ON CENTER. PRIOR COORDINATION WITH THE LANDLORD. BOARD CORE,1 PLY I.1 PLY DOORS,3 PLY HARDWARE FACE VENEER BONDED TO FRAME/CORE.ALL d STILES AND RAILS BONDED TO CORE. G.D. METAL FURRING,FRAMING AND ACCESSORIES: ASTM C645.GA-216 AND GA-600,SPACED NOT MORE THAN lb INCHES OC. •- C C 111. SECTION 01040 - PROJECT COORDINATION G. FINISH FOR DOORS TO BE CUSTOM GRADE ANI FINISH SYSTEM TR-4;CONVERSION VARNISH,OPEN GRAIN G.E. HOOD FURRING,FRAMING AND ACCESSORIES: 6A-216,AND GA-600,CONSTRUCTION GRADE HOOD (FILLED FINISH),MEDIUM GLOSS RUBBED EFFECT,WITH ONE ADDITIONAL TOPCOAT. CD N FURRING NOM. 1 INCH X2 INCHES,SPACED MAXIMUM OF lb INCHES OC. C cla USE WRITTEN DIMENSIONS ONLY DO NOT SCALE DRAWINGS, III. SECTION 08110 - DOOR HARDWARE G.F. FASTENERS: ASTM C5I4.ASTM C100.2.GA-216. at= , G.G. ANCHORAGE TO SUBSTRATE: TIE WIRE,WRENS AND OTHER METAL SUPPORTS,OF TYPE AND SIZE TO L0) 0) A. REPORT ALL DISCREPANCIES IN DIMENSIONS,CODE COMPLIANCE OR OTHER ISSUES TO ARCHITECT PRIOR SUIT APPLICATION;TO RIGIDLY SECURE MATERIALS IN PLACE. A. DRAWINGS AND GENERAL PROVISIONS OF CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY G.H. ADHESIVE: ASTM C551.GA-216. C "71- TO t O O TO PROCEEDING WITH PROJECT OR ORDERING ANY MATERIALS. C 0 -0 B. THE CONTRACTOR IS RESPONSIBLE TO COORDINATE ALL MECHANICAL,ELECTRICAL AND PLUMBING CONDITIONS AND DIVISION 1 SPECIFICATION SECTIONS,APPLY TO WORK OF THIS SECTION. H. GYPSUM BOARD MATERIALS: fa c0 > _U cis _ O 0 B. SUBMITTALS: HA. STANDARD GYPSUM BOARD: ASTM C36;1/2 INCH THICK,MAXIMUM PERMISSIBLE LENGTH;ENDS CO r INSTALLATIONS WITH THE STRUCTURAL SYSTEM TO ASSURE THAT PROPER CLEARANCES CAN BE ACHIEVED, O O PRIOR TO FABRICATING ANY SYSTEMS. BA. SUBMIT FINAL HARDWARE SCHEDULE ORGANIZED BY "HARDWARE SETS",TO INDICATE SPECIFICALLY SQUARE CUT,TAPERED AND BEVELED EDGES. N O O THE PRODUCT TO BE FURNISHED FOR EACH ITEM REQUIRED ON EACH DOOR. H.B. FIRE RATED GYPSUM BOARD: ASTM G36;FIRE RESISTIVE TYPE,UL RATED;I/2 OR 5/8 INCH THICK, `�� ? -o gy ms C. DIMENSIONS INDICATED WITH +/-SHALL BE FIELD VERIFIED BY THE GC. ® k D. IT I5 EACH CONTRACTORS RESPONSIBILITY TO CHECK MODEL NUMBERS OF COMPONENTS SPECIFIED IN B.B. FURNISH TEMPLATES TO EACH FABRICATOR OF DOORS AND FRAMES,A5 REQUIRED FOR MAXIMUM PERMISSIBLE LENGTH;ENDS SQUARE GUT,TAPERED AND BEVELED EDGES. C`:-" U c6 a_ cis c6 c6 PREPARATION TO RECEIVE HARDWARE. THIS PROJECT WITH DESCRIPTION OF PRODUCT FOR CONFORMANCE WITH THE INTENT OF THE DESIGN. IF H.G. MOISTURE RESISTANT GYPSUM BOARD: ASTM 0630;1/2 OR 5/8 INCH THICK,MAXIMUM PERMISSIBLE > Cr) > N N G. PRODUCTS: LENGTH;ENDS SQUARE CUT,TAPERED AND BEVELED EDGES. =z v NCV N DISCREPANCIES ARE DISCOVERED,NOTIFY THE ARCHITECT PRIOR TO ORDERING MATERIALS.E. PROVIDE ALL DEMOLITION A5 INDICATED ON DRAWINGS AND A5 REQUIRED TO COMPLETE THE WORK. GA. ACCEPTABLE MANUFACTURES/PRODUCTS H.D. CEMENTITIOUS BACKING BOARD: HIGH DENSITY,GLA55 FIBER REINFORCED, 1/2 INCH THICK;2 INCH Q U CO U d 6: F. PROVIDE ALL CUTTING AND PATCHING OF EXISTING WALLS,FLOORS AND CEILINGS AS REQUIRED TO CAA. ALL HARDWARE TO BE NEW. FINISH TO BE BRUSHED ALUM,CLEAR COATED OR MATCH BUILDING (50 MM) WIDE,COATED GLASS FIBER TAPE FOR JOINTS AND CORNERS;MANUFACTURED BY U.S. ACCOMMODATE NEW LAYOUT. PATCH TO MATCH EXISTING ADJACENT WALLS,FLOORS AND CEILINGS FOR STANDARDS.VERIFY WITH LANDLORD/TENANT. THE GRADE OF THE HARDWARE IS TO BE A5 GYPSUM;PRODUCT;DUROCK. SMOOTH EVEN APPEARANCE UNLESS OTHERWISE INDICATED. SPECIFIED HEREIN.THE FOLLOWING SPECIFICATION IS PRESENTED AS A GUIDE FOR QUALITY I. ACCESSORIES: AND FUNCTION.ACCEPTABLE MANUFACTURERS FOR VARIOUS TYPES OF PRODUCTS ARE LISTED I.A. ACOUSTICAL INSULATION: ASTM G665;PREFORMED FRICTION FIT TYPE,UNFACED,2-1/2 INCH THICK, IV. SECTION 01300 - SUBMITTALS BELOW.AN ASTERISK(') FOLLOWING A MANUFACTURERS NAME DESIGNATES MANUFACTURER 2.5 LBS/CU FT. WHOSE PRODUCTS ARE INDICATED IN FINISH HARDWARE SCHEDULE.SUCH PRODUCTS ARE LISTED IB. ACOUSTICAL SEALANT: NON-HARDENING,NON-SKINNING,FOR USE IN CONJUNCTION WITH GYPSUM IN THE SCHEDULE BY SPECIFIC REFERENCE TO MANUFACTURERS CATALOG NUMBERS. EXCEPT BOARD. PROJECT: A. THE GC SHALL SUBMIT ALL SHOP DRAWINGS,PRODUCT LITERATURE AND SAMPLES TO THE ARCHITECT AS OTHERWISE INDICATED,PRODUCTS OF EQUIVALENT QUALITY,DESIGN AND FUNCTION BY I.G. CORNER BEADS: METAL. WITHIN TEN(10) DAYS AFTER THE START OF CONSTRUCTION. OTHER LISTED MANUFACTURERS MAY BE USED,SUBJECT TO APPROVAL OF ARCHITECT. I.D. EDGE TRIM: GA 201 AND GA 216;TYPE J BEAD. B. SUBMIT SHOP DRAWINGS FOR THE FOLLOWING NORK AND OR ITEMS: G.B. MATERIALS AND FABRICATION: I.E. JOINT MATERIALS: ASTM C415;GA 201 AND GA 216;REINFORCING TAPE,JOINT COMPOUND, BA. ALL DOOR HARDWARE. CUBA. FINISH AND BASE MATERIAL DESIGNATIONS ARE INDICATED IN ACCORDANCE NITH ANSI A156.18 ADHESIVE,AND WATER. Q B.B. ALL DOORS AND FRAMES. OR THE NEAREST TRADITIONAL U.S.COMMERCIAL FINISH. IFW. FASTENERS: ASTM CI002,TYPE S12, AND GA-216. B.G. MILLWORK,CABINETRY,HARDWARE. CBAA. WHERE BASE MATERIAL AND QUALITY OF FINISH ARE NOT OTHERWISE INDICATED,PROVIDE J. EXAMINATION: 0 B.D. STEEL FRAMING AND LINTELS. AT LEAST THE COMMERCIALLY RECOGNIZED QUALITY SPECIFIED IN ANSI A156 SERIES JA. VERIFY SITE CONDITIONS UNDER PROVISIONS OF SECTION 01039. B.E. NEW MECHANICAL AND ELECTRICAL EQUIPMENT,FIXTURES AND ACCESSORIES. STANDARDS APPLICABLE TO EACH PARTICULAR TYPE OF HARDWARE. K. METAL STUD INSTALLATION: Ce C. SUBMIT MANUFACTURER'S LITERATURE FOR ARCHITECT'S REVIEW AND APPROVAL FOR THE FOLLOWING D. DOOR LOCKSETS,LATCHSETS: KA. INSTALL STUDS IN ACCORDANCE WITH ASTM 0754.GA-201,GA-216 AND GA-600.AND 0 L.L., ITEMS,INCLUDING BUT NOT LIMITED TO: DA. ALL SETS SHALL BE LEVER SETS TO MEET OR EXCEED STATE REGULATED ACCESSIBLE MANUFACTURER'S INSTRUCTIONS. 5/ G.A. ACOUSTICAL CEILING TILE. REQUIREMENTS.MANUFACTURED BY SGHLAGE OR EQUAL.LEVER SET STYLE TO BE SELECTED BY K.B. STUD SPACING: lb INCHES ON CENTER,OR CLOSER. 0 Q G.B. LIGHT FIXTURES. ARCHITECT. K.G. REFER TO DRANINGS FOR INDICATION OF PARTITIONS EXTEND STUD FRAMING THROUGH THE CEILING _ G.G. DOOR AND FRAMES. DAA. LOCKSETS: CYLINDER SETS KEYED TO BUILDING SYSTEM MASTER KEY SYSTEM. TO THE STRUCTURE ABOVE. MAINTAIN CLEARANCE UNDER STRUCTURAL BUILDING MEMBERS TO AVOID Lu D M G.D. HARDWARE(DOOR,CABINETRY,ETC). E. DOOR CONTROL DEVICES: DEFLECTION TRANSFER TO STUDS.PROVIDE EXTENDED LEG CEILING RUNNERS. CNN EA. MFRS OF OVERHEAD CLOSERS: CORBIN,DORMA,LGN•,NORTON,5.PARKER,RIXSON-FIREMARK, K.D. DOOR OPENING FRAMING: INSTALL DOUBLE STUDS AT DOOR FRAME JAMBS. INSTALL STUD TRACKS < () N r V. SECTION 01500 - CONSTRUCTION FACILITIES RUSSWIN,SARGENT,YALE. ON EACH SIDE OF OPENING,AT FRAME HEAD HEIGHT,AND BETWEEN STUDS AND ADJACENT STUDS. m I� EAA. LCN: 4040 SUPER SMOOTHEE SERIES,HOLD OPEN ARM.WITH DELAYED ACTION CLOSER,FORCE t \ 1"1DK.E, BLOCKING: SGREN WOOD BLOCKING TO STUDS.BOLT OR SCREW STEEL CHANNELS TO STUDS. ^, z Cl A. IF NO POWER 15 AVAILABLE,GG TO PROVIDE POWER VIA GENERATORS OR ARRANGE METER TO OPEN DOOR TO BE SET AT STATE REGULATED ACCESSIBLE REQUIREMENT STANDARD 5# INSTALL BLOCKING FOR SUPPORT OF PLUMBING FIXTURES,TOILET PARTITIONS,NALL CABINETS, �� N c INSTALLATION AND PAY FOR ALL POWER USED. IF PONER 15 AVAILABLE,GC TO CONNECT TO OWNERS PRESSURE.FINISH TO BE BRUSHED ALUM. TOILET ACCESSORIES,AND HARDNARE,AND WOOD BASE AND TRIMS. �e * (,/) C) CC POWER SUPPLY ONLY AT LOCATIONS DESIGNATED BY LANDLORD. E.B. MFR'S.OF HOLDERS,STOPS,BUMPERS: BALDWIN,BROOKLINE,BUILDERS BRA55 WORKS,CIPCO, L. WALL FURRING INSTALLATION: g ) Lu z O B. PROVIDE PROTECTION OF THE EXISTING FACILITIES AT ALL TIMES DURING CONSTRUCTION. CORBIN,DOOR CONTROLS INT'L,GLYNN-JOHNSON,IVES',LIBERTY,5.PARKER,QUALITY,SARGENT, L.A. ERECT NALL FURRING FOR DIRECT ATTACHMENT TO CONCRETE BLOCK. 12 BA. PROVIDE A DUMPSTER AND REMOVE ALL CONSTRUCTION DEBRIS AT THE END OF EACH DAY. LEAVE STANLEY,OR TRIANGLE BRASS. L.B. ERECT FURRING CHANNELS VERTICALLY;SPACE MAXIMUM lb INCHES ON CENTER,NOT MORE THAN 4 THE SITE BROOM CLEAN. LOCATE DUMPSTER AND REMOVE ALL WASTES IN ACCORDANCE WITH THE E.BA. DOOR STOP;WALL STOP;232N INCHES FROM FLOOR AND CEILING LINES.SECURE IN PLACE ON ALTERNATE CHANNEL FLANGES AT O O ii rz z LANDLORD'S REQUIREMENTS AND WITHIN THE TIME PERIODS ALLOWED BY THE LANDLORD. E.B.B. FLOOR STOP;DOME TYPE 242F. MAXIMUM 24 INCHES ON CENTER,OR THROUGH WOOD FURRING AT MAXIMUM lb INCHES OC. B.B. PROVIDE TEMPORARY PROTECTION OF THE CARPET AND OTHER FINISHES ON THE WAY TO AND FROM EB.B.A. PROVIDE GRAY RUBBER EXPOSED RESILIENT PARTS. M. FURRING FOR FIRE RATINGS: V) V) Q THE WORK AREAS. E.G. SIZE AND MOUNT UNITS INDICATED OR, IF NOT INDICATED,TO COMPLY WITH MFRS RECOMMENDATIONS MA. INSTALL FURRING A5 REQUIRED FOR FIRE RESISTANCE RATINGS INDICATED AND TO GA-600z < VI FOR THE EXPOSURE CONDITION.REINFORCE THE SUBSTRATE AS RECOMMENDED. REQUIREMENTS. �"I ~ VI. SECTION 01631 - PRODUCT SUBSTITUTIONS E.CA. WHERE PARALLEL-ARM CLOSERS ARE INDICATED,PROVIDE UNITS ONE SIZE LARGER THAN N. CEILING FRAMING INSTALLATION: I RECOMMENDED FOR STANDARD-ARM UNITS. NA. INSTALL IN ACCORDANCE WITH ASTM 0154.6A 201 AND GA 216.AND WITH MANUFACTURER'S in A. NO SUBSTITUTIONS TO SPECIFIED MATERIALS AN/OR BRANDS OF MATERIALS WILL BE ACCEPTED UNLESS E.D. HINGES-STAINLESS STEEL,BALL-BEARING,COLOR AND TEXTURE TO MATCH LEVER SET.USE INSTRUCTIONS. Q APPROVED BY THE ARCHITECT, IN WRITING,PRIOR TO CONSTRUCTION. ANY CONTRACTOR REQUESTING EXTERIOR OR INTERIOR GRADE PER DOOR LOCATION. NON-REMOVABLE PINS AT EXTERIOR N.B. COORDINATE LOCATION OF HANGERS WITH OTHER WORK, SUBSTITUTIONS SHALL SUBMIT DRAWINGS AND/OR PRODUCT LITERATURE ALONG WITH THE AMOUNT OF COST LOCATIONS.SEE DOOR SCHEDULE FOR MORE INFORMATION. N.G. INSTALL CEILING FRAMING INDEPENDENT OF WALLS,COLUMNS,AND ABOVE CEILING WORK. SAVINGS FOR THE ITEM IN QUESTION. THE CONTRACTOR MUST ALLOW THE ARCHITECT AT LEAST SEVEN N.D. REINFORCE OPENINGS IN CEILING SUSPENSION SYSTEM WHICH INTERRUPT MAIN CARRYING CHANNELS Q BUSINESS DAYS TO DETERMINE THE SUITABILITY OF THE SUBSTITUTION. F. HARDWARE FINISHES: OR FURRING CHANNELS,WITH LATERAL CHANNEL BRACING. EXTEND BRACING MINIMUM 24 INCHES FA. ALL HARDWARE,UNLESS NOTED OTHERWISE,SHALL BE BRUSHED ALUM N/CLEAR COAT OR MATCH PAST EACH END OF OPENINGS. r-I BUILDING STANDARDS. N.E. LATERALLY BRACE ENTIRE SUSPENSION SYSTEM. Q VII. SECTION 01100 - PROJECT CLOSEOUT G. MISCELLANEOUS DOOR HARDWARE: O. GYPSUM BOARD INSTALLATION: r'--1 G.A. SILENCERS: PROVIDE SILENCERS IN METAL DOOR FRAMES,UNLESS NOT PERMITTED FOR FIRE RATING, OA. INSTALL GYPSUM BOARD IN ACCORDANCE WITH GA-201,GA-216 AND GA-600 AND MANUFACTURER'S A. SUBMIT REQUEST FOR SUBSTANTIAL COMPLETION WALK THRU,FOLLOWED BY FINAL APPLICATION FOR OR UNLESS BUMPER-TYPE WEATHERSTRIPPING IS PROVIDED;3 PER SINGLE-DOOR FRAME,4 PER INSTRUCTIONS. PAYMENT AND NOTIFICATION OF FINAL INSPECTION. DOUBLE-DOOR FRAME. O.B. ERECT SINGLE LAYER STANDARD GYPSUM BOARD VERTICAL,WITH ENDS AND EDGES OCCURRING B. PROVIDE A COPY OF FINAL APPROVAL BY THE GOVERNING AUTHORITIES AND CERTIFICATE OF G.B. MFR'S OF MISCELLANEOUS HARDNARE: PROVIDE PLATES,TRIM,LETTER BOX,VIEWERS,KNOCKERS, OVER FIRM BEARING. OCCUPANCY. BELLS,AND SIMILAR UNITS A5 INDICATED,PRODUCED BY A-J MFG.CO.,BALDWIN',BROOKLINE, O.G. ERECT SINGLE LAYER FIRE RATED GYPSUM BOARD VERTICALLY,WITH EDGES AND ENDS OCCURRING , C. FINAL CLEANING: BUILDERS BRASS WORKS,CIPCO, IVES,TRIANGLE BRASS. OVER FIRM BEARING. CA. REMOVE ALL TEMPORARY BARRIERS AND PROTECTIONS. 6.C. FABRICATE PLATES AND EDGE TRIM UNITS 2"SMALLER THAN ACTUAL DOOR DIMENSION. INSTALL O.D. USE SCREWS WHEN FASTENING GYPSUM BOARD TO WOOD OR METAL FURRING OR FRAMING. G.B. CLEAN ALL INTERIOR FINISH SPACES CLEAN FROM ALL DIRT,DUST,DEBRIS,STAINS,SPILLS,ETC. WITH SELF-TAPPING SCREWS. O.E. DOUBLE LAYER APPLICATIONS:USE GYPSUM BACKING BOARD FOR FIRST LAYER,PLACED POLISH AND WIPE ALL SURFACES. REMOVE TEMPORARY LABELS,FOREIGN MATERIALS,VACUUM G.CA. PROVIDE .050" THICK(18 GA,) STAINLESS STEEL WITH BEVELED EDGES AND BRUSHED ALUM PERPENDICULAR TO FRAMING OR FURRING MEMBERS.USE FIRE RATED GYPSUM BACKING BOARD FOR MARK: ISSUE: DATE: CARPETS AREAS,WET MOP HARD SURFACES. FOR KICK PLATES,ARMOR PLATES,AND EDGE PROTECTION STRIPPING.MATCH ADJACENT FIRE RATED PARTITIONS. Review 50% 01/18/16 D. TURN OVER ALL WARRANTIES,NOTICES,AND OPERATING INSTRUCTIONS TO THE OWNER. HARDWARE FINISHES.WHERE MORE THAN ONE FINISH IS ADJACENT TO ITEM,CONSULT THE O.F. PLACE SECOND LAYER PERPENDICULAR TO FIRST LAYER.OFFSET JOINTS OF SECOND LAYER FROM Review 90% 02/05/16 E. SEE ENGINEER DRANINGS FOR FURTHER CLOSEOUT REQUIREMENTS. ARCHITECT. JOINTS OF FIRST LAYER. INSTALL ACCORDING TO UL AND MANUFACTURER'S REQUIREMENTS. Property Owner Review 02/23/16 H. THRESHOLDS: O.G. TREAT CUT EDGES AND HOLES IN MOISTURE RESISTANT GYPSUM BOARD WITH SEALANT. DIVISION 2 - SITE CONSTRUCTION HA. MFRS OF THRESHOLDS: COMBO ALUM.PRODUCTS,K.N.CROWDER,A-J MAY,NATIONAL GUARD, O.H. PLACE CONTROL JOINTS CONSISTENT WITH LINES OF BUILDING SPACES AS INDICATED. IF NO Permit Set 03/11/16 PEMKO',REESE,ZERO. DIRECTION 15 INDICATED,THEN LOCATIONS ARE TO BE SELECTED BY ARCHITECT/ENGINEER. I. SECTION 02012 - MINOR DEMOLITION FOR REMODELING H.B. PROVIDE EXTRUDED ALUMINUM THRESHOLD OF TYPE,DESIGN AND PROFILE INDICATED,COMPLETE 0.1. PLACE CORNER BEADS AT EXTERNAL CORNERS. USE LONGEST PRACTICAL LENGTH. PLACE EDGE WITH REPLACEABLE RESILIENT VINYL WIPER-TYPE INSERT. PROVIDE NON-CORROSIVE FASTENERS. TRIM WHERE GYPSUM BOARD ABUTS DISSIMILAR MATERIALS. A. DISCONNECT,DISMANTLE,REMOVE,CAP ANY UTILITIES NITHIN THE SPACES AS REQUIRED FOR THE WORK. I. INSTALLATION: O.J. INSTALL BACKING BOARD OVER METAL STUDS AND PLYWOOD SHEET IN ACCORDANCE WITH B. PROVIDE,ERECT AND MAINTAIN BARRICADES,AND PROVIDE SIGNAGE INDICATING DANGEROUS, IA. HARDNARE MOUNTING HEIGHTS: DOOR AND HARDWARE INSTITUTE "RECOMMENDED LOCATIONS FOR MANUFACTURER'S INSTRUCTIONS. HAZARDOUS OR DELETERIOUS CONDITIONS OR AREAS. BUILDERS HARDNARE FOR STANDARD STEEL DOORS AND FRAMES",EXCEPT AS OTHERNISE O.K. APPLY GYPSUM BOARD TO CURVED WALLS IN ACCORDANCE WITH 6A-216. INDICATED. P. JOINT TREATMENT: - DIVISION 6 - WOOD AND PLASTICS I.B. INSTALL EACH HARDWARE ITEM TO COMPLY WITH MANUFACTURER'S INSTRUCTIONS AND PA. TAPE,FILL,AND SAND EXPOSED JOINTS,EDGES,AND CORNERS TO PRODUCE SMOOTH SURFACE RECOMMENDATIONS. READY TO RECEIVE FINISHES. I.G. SET THRESHOLDS FOR EXTERIOR DOORS IN FULL BED OF BUTYL-RUBBER OR POLYISOBUTYLENE P.B. FEATHER COATS ONTO ADJOINING SURFACES 50 THAT CAMBER 15 MAXIMUM 1/32 INCH. I. SECTION 06402 - ARCHITECTURAL WOODWORK MASTIC SEALANT. REMOVE EXCESS SEALANT AND CLEAN ADJACENT SURFACES. P.G. TAPE JOINTS AND CORNERS OF CEMENTITIOUS BACKING BOARD. J. ADJUST AND CLEAN: Q. TOLERANCES: A. THIS SECTION INCLUDES: INTERIOR STANDING AND RUNNING TRIM AND RAILS,WOOD CABINETS,LAMINATE JA. HARDWARE ADJUSTMENT: RETURN TO PROJECT ONE MONTH AFTER TENANTS OCCUPANCY,AND Q.A. MAXIMUM VARIATION OF FINISHED GYPSUM BOARD SURFACE FROM TRUE FLATNESS: 1/8 INCH IN 10 CLAD CABINETS,CABINET TOPS(COUNTERTOPS),AND INTERIOR DOOR AND NINDOW FRAMES. ADJUST HARDWARE TO PROPER OPERATION AND FUNCTION. INSTRUCT TENANT'S PERSONNEL IN FEET IN ANY DIRECTION. B. WHERE WOODWORK IS INDICATED TO BE FITTED TO OTHER CONSTRUCTION,CHECK ACTUAL DIMENSIONS OF PROPER MAINTENANCE AND ADJUSTMENT. OTHER CONSTRUCTION BY ACCURATE FIELD MEASUREMENTS;SHOW RECORDED MEASUREMENTS ON FINAL II. SECTION 09500 - ACOUSTICAL CEILINGS SHOP DRAWINGS. COORDINATE MANUFACTURING SCHEDULE NITH CONSTRUCTION PROGRESS TO AVOID DIVISION q - FINISHES DELAY OF WORK A. PER ROOM FINISH SCHEDULE C. ALL HIGH PRESSURE DECORATIVE LAMINATE TO BE AS SPECIFIED ON THE DRAWINGS. ALL FINISHES TO BE I. SECTION 09250 - GYPSUM BOARD SYSTEMS PROJECT#: 15085.01 SELECTED BY THE ARCHITECT IF NOT SPECIFIED ON THE DRAWINGS. III. SECTION 09650 - RESILIENT FLOORING G.A. ALL LAMINATES TO BE REGULAR GRADE 0.050" THICK,UNO. A. SECTION INCLUDES: DRAWN BY: DN CHECKED BY: DJB D. COMPLETE FABRICATION,INCLUDING ASSEMBLY,FINISHING,AND HARDWARE APPLICATION,BEFORE AA. METAL STUD WALL FRAMING. A. PER ZOUPI SCHEDULE SHIPMENT TO PROJECT SITE TO MAXIMUM EXTENT POSSIBLE.DISASSEMBLE COMPONENTS ONLY AS NECESSARY FOR SHIPMENT AND INSTALLATION. WHERE NECESSARY FOR FITTING AT SITE,PROVIDE AMPLE A.B. WOOD STUD NALL FRAMING. Arkinetics,Inc.and their Consultants shall be deemed the authors IV. SECTION 09688 - CARPET ALLOWANCE FOR SCRIBING,TRIMMING,AND FITTING. A.G A.D. ACOUSTICAL INSULATION, retain all common law,statutory and other reserved rights,including E. MATERIALS: A.E. GYPSUM BOARD. A. PER ZOUP!SCHEDULE copyrights.The Instruments of Service shall not be used for future IV EA. ALL CABINETRY TO BE MERILLAT OR EQUAL,LINO. STYLE AND COLOR BY ARCHITECT. A.F. GYPSUM SHEATHING,CEMENTITIOUS BACKER BOARD. additions or alterations to this Project or for other projects,without Q E.B. COMPLY WITH THE APPROPRIATE ANI QUALITY STANDARD AS LISTED BELOW: A.G. TAPED AND SANDED JOINT TREATMENT. V. SECTION O1900 - PAINTING the prior written agreement of Arkinetics,Inc.Any unauthorized use C E.BA. ALL COUNTERS AND CABINETRY -CUSTOM GRADE. of the Instruments of Service shall be at the Owner's sole risk and E.B.B. DOOR AND WINDOW FRAMES-CUSTOM GRADE. B. REFERENCES: without liability to Arkinetics,Inc.and their Consultants N E.B.G. RUNNING TRIM- CUSTOM GRADE. BA. ASTM C36 -GYPSUM WALLBOARD. A. PER ZOUP!SCHEDULE arkinetics 0 2016 E.B.D. BOOKCASES AND MISC.WOODWORK-CUSTOM GRADE. B.B. ASTM G19 -GYPSUM SHEATHING BOARD. c") F. COMPLY WITH AN SECTION 1500 FOR FINISHING OF WOODWORK. ALL WOODWORK TO BE FINISHED PER B.G. ASTM G665 - MINERAL FIBER BLANKET THERMAL INSULATION FOR LIGHT FRAME CONSTRUCTION AND DIVISION 10 - SPECIALTIES DRAWING TITLE: —i CUSTOM GRADE OP-4 OR TR-4,CONVERSION VARNISH SYSTEM WITH AT LEAST ONE ADDITIONAL FINISH MANUFACTURED HOUSING. U COAT. B.D. ASTM C154 - INSTALLATION OF FRAMING MEMBERS TO RECEIVE SCREW ATTACHED GYPSUM I. SECTION 10520 - FIRE PROTECTION SPECIFICATION S > WALLBOARD,BACKING BOARD,OR NATER RESISTANT BACKING BOARD.B.E. ASTM C840 - APPLICATION AND FINISHING OF GYPSUM BOARD. G. TO THE GREATEST EXTENT POSSIBLE,FINISH ARCHITECTURAL WOODWORK AT THE FACTORY. DEFER ONLY v FINAL TOUCH-UP,CLEANING,AND POLISHING UNTIL AFTER INSTALLATION. B.F. ASTM E119 - FIRE TESTS OF BUILDING CONSTRUCTION AND MATERIALS. A. GC SHALL SUPPLY AND INSTALL TYPE MP-6 ABC FIRE EXTINGUISHER(5)WITHIN THE PREMISES AS B.G. GA-20I -GYPSUM BOARD FOR WALLS AND CEILINGS. SPECIFIED BY GOVERNING LOCAL CODE. II. SECTION 06112 - FRAMING AND SHEATHING B.H. GA-.21b -RECOMMENDED SPECIFICATIONS FOR THE APPLICATION AND FINISHING OF GYPSUM BOARD.\ J B.I. GA-600 - FIRE RESISTANCE DESIGN MANUAL. - A. FOLLON RECOMMENDED OR PREFERRED GUIDELINES OF THE FOLLOWING REFERENCE STANDARDS: ALSC; C. SYSTEM DESCRIPTION: R/�� /� xi - AMERICAN LUMBER STANDARDS COMMITTEE,APA;AMERICAN PLYWOOD ASSOC..,NFPA;NAT'L FOREST CA. ACOUSTICAL ATTENUATION FOR INTERIOR PARTITIONS: IN ACCORDANCE WITH ASTM E40. THIS DfWV V1NG CONTAINS GENERAL SPECIFICATIONS�/� K PRODUCTS ASSOC.,SPIB;SOUTHERN PINE INSPECTION BUREAU,WGLIB;WEST COAST LUMBER INSPECTION G.B. GYPSUM WALL BOARD SYSTEM ON WOOD OR METAL FRAMING. STANDARDS FOR COMMON BUILDING MATERIALS. SEE BUREAU,WWPA;WESTERN WOODS PRODUCTS ASSOC. D. QUALITY ASSURANCE: B. LUMBER GRADING RULES: NFPA,RIS,SPIE,WCLIB,WWPA. DA. PERFORM WORK IN ACCORDANCE WITH ASTM 0840.GA 201,GA-216,AND 6A-600. /� m C. FRAMING AND BLOCKING TO BE FIRE RETARDANT TREATED PER THE LOCAL BUILDING CODE!UNO) DRAV V1NGS FOR ADDITIONAL INFORMATION. DRAWINGS SUPERSEDES THIS SHEET. SOME INFORMATION LISTED HEREIN w SHEET#: MAY NOT BE APPLICABLE TO ALL PROJECTS. Gl. 01 _.1 CD / • 0 IV -n • TRASH COMPACTOR PROJECT LOCATION DUMPSTER LOGATION ZOUP! #213 LOCATION (GARD50ARD ONLY) SEAL EU L NG A EUILDING 5c c, o r-- 0 O. — V/ r o g C a),_cv c�? tn xn N n IN N N IN N N In N n I oNo 'CIN-■� W -2 mit _ � cl .0 c -. C o I n (1 n• 0 N h N n N n n o E ca ro 4- wf� 111 x I I0 > _ o 0 0 nU JNJ LCL CI n V C + U r I 1 • . I ,L,/ C Ll gii ....m_ o ii.lt 21) i . . I I i • • x L eC c (i".$ cn d C _ I I i .• x W vM 0 c O coN _ C- • W W a o . \ ai I I I ` t.. +. C C r1 r� q ;' U co 0_ (a 6 6 WWl LA.1 o /181 D\JI ii-,,,-, ; _ - - _ • W ■ N W Q Uc� U b: Li.: W W W - H - - I a ,. I PATIO H W " W H w I PROJECT: ' 'rv""— 1::::") < O CCIE CC,. W Q al 0 CC . al C=1 s 34 ... ® w m 1 r*..lt` OC d NI w c t rn Q cv __.�,.,._. - 110 Z rn1 II I I I I IA'1 Oil i 4 (V:i9' i_ w O Z L7 E1 • O Z O If 1 t Li L-D f' f .4 +'t 1:::k.' tf) /iill �` / i , y �. s� 11 :. /./..// . 2:4) r—I Jf 1 /.K // LE-----Jr • t �1 MARK: ISSUE: DATE: Review 50% 01/18/16 PARTIAL ARCHITECTURAL SITE PLAN 1 _ Review 90% 02/05/16 vALA/® J I ,., II Property Owner Review 02/23/16 SCALE: 1/32" = 1'-0" J {i f "' CPermit Set 03/11/16 NOTE: THIS SITE PLAN 15 DIAGRAMMATIGAL AND SHALL NOT � , DE CONSTRUED A5 AN ACTUAL SURVEY. • NORTH h h 4 s BUL NS C PROJECT*: 15055.01 DRAWN BY: DKN CHECKED BY: DJB Arkinetics,Inc.and their Consultants shall be deemed the authors and owners of their respective Instruments of Service and shall retain all common law,statutory and other reserved rights,including copyrights.The Instruments of Service shall not be used for future NJ additions or alterations to this Project or for other projects,without Q the prior written agreement of Arkinetics,Inc.Any unauthorized use C of the Instruments of Service shall be at the Owner's sole risk and without liability to Arkinetics,Inc.and their Consultants N arkinetics O 2016 Co) DRAWING TITLE: > SITE PLAN 7 00 x M g Go M -{ SHEET#: W r 1 r AS • 01Q W il (----i) (, (---2.--\) .._____) / ROOF LINE ABOVE z_A.:2‘.. ).:I i C-11'' 1 I 1 I SEAL • , \ i . 0 WI 6 46 „, -- I . r • GM p O 1 0 0 0 g 1 ® - - 1! - ~ - `D LL H: Zno elln, 1 1 ! k I- 0 1.1) �r T / Ii 0 j O J NJ Q LL II z o v O '� u, ui — L_ _J 1C +� rI • C — .J L J jf I i •■■.. ,_, c in • DEMO STUD 0 i WALL DP-3 , H ai o � /%�1 DP-4I o c PARKING / ROOF LINE ABOVE I /// g !lY L I r I �{� a!? a _ c� DP-3 I el_ , a� O rn ai & co ca DP4 I DP2 • li� 3 c',71 1:5I � ti 4013-10) DP-8 e---:;f4 . . . `r= a0'� co > cvcv Q UCr) o dim L - - - -�_=�- RiOF I- _ _ _ SS !- CATWALK 1 A GE ' I _ _ _ �L I i Hw��DP 5� 1 • ABOVE TO j REMAIN I DP-8 !..[ 11 � IPROJECT. \ I _ I I IC - J I PRINKLI<RL0. -._._ • WALL \\ ... -- Q ' I / GNU III1 , ! . % U.. — 0 I• HVAC DUCT /1P-3 i , 0 OC nI DP 4 I- Q DUCT 12'-6" TO BTM 1 I i W D m `t / I I DP 6 \1/41 T—ID Z dl Cy i t ,CH' u' 11 P 1 "' DP 1 % N O fY DP 7W ELECIL7Icc Z D I ' �xr G R�� ~, VI L7 = Q / i I ' • • I I i I V)! I Q i I1 � I V)a — 7-1 I O d- 1-1 ROOF HATCH 1 GENERAL DEMOLITION NOTES: KEYED NOTES: CATWALK TOREMAIN IMARK: ISSUE: DATE: I. FIELD VERIFY EXISTING CONDITIONS/DIMENSIONS PRIOR TO DP-1 ELECTRICAL PANELS AND LIGHTING CONTROL PANEL, WORD Review 50% 01/18/16 START OF WORK. WITH ELECTRICAL DRAWINGS FOR WORK REQUIRED. I Review 90% 02/05/16 2. PROVIDE DEMOLITION A5 INDICATED ON DRAWINGS AND A5IDP 2 REMOVE PLUMBING FIXTURES AND ALL TOILET ROOM Property Owner Review 02/23/16 REQUIRED TO COMPLETE THE WORK SHOWN. ASSOCIATED ITEMS, WORD WITH PLUMBING DRAWINGS Permit Set 03/11/16 3. DEMOLITION DIMENSIONS ARE TO BE FIELD VERIFIED AND <LID > REMOVE EXISTING WOOD FLOOR FINISH AND BASE AND PREP COORDINATED WITH FLOOR PLAN INFORMATION. FOR NEW FINISHES. • 4. PROVIDE CUTTING AND PATCHING OF EXISTING WALLS, FLOORS DO-7>A REMOVE EXISTING CEILING GRID, TILE, LIGHTS AND OTHER AND CEILINGS A5 REQUIRED TO ACCOMMODATE NEW LAYOUT. ASSOCIATED CEILING ITEMS, WOW. WITH ELECTRICAL ' PATCH TO MATCH EXISTING ADJACENT WALLS, FLOORS AND DRAWINGS. . CEILINGS FOR SMOOTH EVEN APPEARANCE,UNLESS OTHERWISE DEMOLITION PLAN NOTED. DP-5 REMOVE EXISTING WATER HEATER. = /&411111 ® SCALE: 1/4" 1' 0" Viagi 5. PROVIDE SHORING/BRACING AS REQUIRED AT AREAS OF DP-6 REMOVE EXISTING MOP SINK AND CAP ALL RELATIVE PIPING. DEMOLITION. STRUCTURE SHALL BE SELF-SUPPORTING AFTER DEMOLITION 15 COMPLETE. DP7EXISTING ALARM PANEL TO BE REMOVED, WORD WITH ELECTRICAL DRAWINGS. NORTH 6. COORDINATE EXTENT AND DISPOSITION OF ALL RELOCATED/SALVAGEABLE ITEMS WITH OWNER. DP $ REMOVE EXISTING FLOOR TILE AND PREP FOR NEW FINISHES. PROJECT#: 15055.01 -I. COORDINATE ASPECTS OF DEMOLITION PLAN WITH NEW FLOOR, DP-9 REMOVE EXISTING HAND SINK AND CAP ALL RELATIVE PIPING. DRAWN BY: DN CHECKED BY: DJB EQUIPMENT AND REFLECTED CEILING PLANS, AS WELL AS MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS. III WALLS THAT ARE EXISTING TO REMAIN WITH TEXTURED PAINT Arkinetics,Inc.and their Consultants shall be deemed the authors SHALL BE SKIM COATED, and owners of their respective Instruments of Service and shall retain all common law,statutory and other reserved rights,including 8, REQUIRED MEANS OF EGRESS SHALL BE MAINTAINED DURING copyrights.The Instruments of Service shall not be used for future CONSTRUCTION AND RENOVATION TO THE BUILDING. 1 ��1 REMOVE EXISTING SOFFIT ABOVE ENTRY DOORS. additions or alterations to this Project or for other projects,without Othe prior written agreement of Arkinetics,Inc.Any unauthorized use of the Instruments of Service shall be at the Owners sole risk and C q, EXISTING FIRE DEPARTMENT VEHICLE ACCESS SHALL BE without liabilityto Arkinetics,Inc and their Consultants TO MAINTAINED DURING CONSTRUCTION. IV arkinetics© 2016 CA) 10. REMOVE ALL DUCTWORK BACK TO EXISTING RTU,UNLESS -I DIRECTED OTHERWISE BY MECHANICAL DRAWINGS, DRAWING TITLE: O DEMOLITION PLAN D II. REMOVE ALL LIGHT FIXTURES AND ASSOCIATED WIRING TO THE 73 O POINT FED FROM. O ;p L2. REMOVE RECEPTACLES, CONDUIT AND WIRING TO THE POINT FED FROM. m 71 13. PREP FLOORS TO RECEIVE NEW FINISHES. K 71 14. REMOVE ALL GYP BD ALONG EXTERIOR PERIMETER OF TENANT (n SPACE AND PREP WALLS FOR NEW FINISHES. M w 1 1 ,:,,, D1 . O1 c• .4._-_,A.) (-2 ROOF LINE ABOVE ) `� ✓ / , I 5q'-I% / / SOFFIT ABOVE, SEE SHEET A2.01 KEYED NOTES: SEAL +. • m , A5.03 ,, + • ,� `FP-1> NEW FLOOR MOP SINK - COORDINATE WITH PLUMBING DRAWINGS. SEAL - Co o o R ALL AREAS AROUND MOP SINK AND AT FLOOR. l \� M = M = `® 4 ,' U NOTE: DIMENSIONS INDICATED ON PLAN FOR LOCATING FLOOR DRAINS RV .L a� FP 2 NEW FLOOR DRAIN, COORDINATE WITH PLUMBING DRAWINGS. I • e to � N Oti SHALL BE VERIFIED BY THE INSTALLING CONTRACTOR AND THE ��+=f��/ a7 p r- FP-3 P-1 1'- `y' % I EQUIPMENT MANUFACTURER PRIOR TO ROUGH-IN, i� C!) . '- 0 - _. - .. a N. L _ ____ __ ___ FP 3 NEW WOOD CHAIR RAIL, COORDINATE WITH DETAIL ON A5.01. ( LL `t - II I - - .�.�}r-r,,,,,-:.4--y-t--n . --- -F-- i- -11 for ' iFoix _ � ., . e1. _ ...-.._.... ._ �� O f�� L�--�1- I - ..--. 1- 1- 1 ... ....-=, �� 1 -- - t # 1L I € 1 IL f �a i r I I ► Iii)0 II , • G d COLUMN / \t I tl-J c �'l 1 __ `l1 . r , j 1 I y' l •n`, I FP 4 HIGH CHAIRS (SHOWN DASHED) BY SMALLWARES COMPANY o \IF 1 r I Inl ...r._::; A) / I. -•�] i a i j Xii 11 l� ' f i�7 I� I I `•�I 1111 — ix I • • I ,� I i ! € 1._ •• Fp-5 NEW WATER HEATER - COORDINATE WITH PLUMBING DRAWINGS.• . 0 0 .775 O J J a IL= - CD �_ �� l+� JI LL Jl! lIL_ Jr r- i �� FP 2 I11 to cA i€ N1 1 r-r-iii FP-3 FP 3 -- - III I 1 I FP-1 1 II I ' I I Fp-6 ALL TABLES, CHAIRS, TRASH RECEPTACLES ARE BY TENANT, AND =I 0- }V—, I! 11 I FP-3 1 s I r-----� ` J INSTALLED BY GG UNLESS NOTED OTHERWISE. Q) 111 r P-1 x6 LOGO MA FP 1 I .__ I i /I iii P-1 i �� ■f• cn 11 SEATING AREA FP 6 L CARPET LINE T ` I I I 1 _ L+ k-- I ,- ,C Nil ;1-'' P-1 ( 100 ) I i is-� 1 ►� '�-- 1 -- I ,., P.D I <pP_7\ INSTALLATION OF SERVING AND KITCHEN EQUIPMENT TO BE �'► y 1: Iv 1 _ l A #i 1-1--11 -� �'� P 19 i L__ iJ 107 mimmo ;' ,li'" I I , COORDINATED BY THE G.G. p (� II 1 r ___ __ __ r l l - , i FP-2 .J COORDINATE SERVING AND KITCHEN EQUIPMENT WITH EQUIPMENT PLAN, ), § rn I, 11 € 1 -11 p J �L „_ 1 I i I 1 _ _ I --�---- �`. WONIEN� �_ I' 11 �# II 1 €I 1 t r y 3 I �, I I I i_ �I 1 J N. rI P C ILII j JJ P-a I r-'„ ? I I _v I I I IFP I I I ;_ ; i Ir i FP 3 F ( 106 )__ --__► F 8 NEW CORNER GUARDS ARE PROVIDED BY KITCHEN EQUIPMENT VENDOR II: r� c o Q P_1, n BY THE GENERAL CONTRACTOR. COORDINATE WITH0 0 I COQ �1__ I AND INSTALLED CO �_� _°�J I I, , I I 1 � HALLW• I G s I _ ah r I En_ I I I I I I s ,� I , EQUIPMENT PLAN. 0 O I J J r l -r-I"j r' t 10� A .01 ,t mL of ai tri i I �� FP 3 ��i , ti • SOFFIT ABOVE, SEE SHEET A2.03 II + y1 -E— 1 11---i� _ , P 1 , IQ2 '' __-�_-j !• o` FP 9 NEW SURFACE MOUNTED LOGO FLOOR MAT BY TENANT. a 1 Imo... Ow '----- H. - i FP-10 NEW BULK CO/ PROVIDED AND INSTALLED BY CO VENDOR. ai g a 04 CV 14xb LOGO MAT ' CARPET LINE �!-I��:: 5_6" 2'-IOy�. L_ FE . - I ■. Q FP 19 �' / / FP 19 UMU ail FP-9 II'-3" FP 13 IM:::" FP 3 I ! P-11 NEW FLOOR RECESSED GREASE INTERCEPTOR LOCATED UNDER r / fP 3 �_ Y , FP 2 3-COMPARTMENT SINK SEE PLUMBING DWGS FOR INFO WORD rLEAVEUNBOLTED. ----- GONrorli LOCATION • FP-2 I LOCATION W/ FOOD SERVICE EQUIPMENT VENDOR AND ZOUP TO AVOID A5.03 S r'1 wITH owNER. - °. fP 1 I.__A i } I ;: FP 14 ! r3x10 L050 MAT .-__ -- te, �„ LEG CONFLICTS. B A5.01 D i FP-9 ''Il �% ��i� _-, \I FP 10 rip— � � E I •J FP-1 GC TO PLACE OCCUPANT LOAD SIGNAGE. PROJECT: \ LI -- I QUEUING �r 1 1 FP 19 - --- ---a -1 A502 P # Pr 1 1 1 -Yl A �+� ( 10 ) ss G I <FP-13> NEW 10# GENERAL PURPOSE WALL MOUNTED FIRE EXTINGUISHER (FE) i! I F i�- . I II _ ; L -ARE,A6 I I i N' __=��i° #L `_J 1..._� 11 -- - =- --..%_ ==, s _; -• - ,_--.1 r---7 GANlal I N COORD WITH FIRE PROTECTION NOTES ON SPECIFICATION SHEET. CONFIRM 0 tis II •is II ___ , r '----+ �� T '� - IIll .--- -- .n- 4 �ti i ii i FP 2 I I,1■ri i LOCATION IN FIELD WITH BUILDING OFFICIAL. Q III IL ui.r FP-6 1r i I [ l [` __ 11 ;>-_y, n. 1El __J FP-7 .. --._._.__-- ' - 4 GC TO PROVIDE AND INSTALL NEW FRP FROM FLOOR TO UNDERSIDE OF II I 1 l I 1=4 a l I I �.._._._., _... e b._�f ,6---- il II 1 Tr-11 i1L _L.J <� �_1_JI - --d FP-14 FP 8 _ __ ..._ CEILING ON GYP BOARDS WALLS. PREP WALL AS REQUIRED - SEE FINISH • LLJ h rxb LOGO MAT FP 2 := •i J • �--r� a LL (� IllllllllllllllllllllllllllllllllllHlllll �• , IIIlillllllllllllllll SCHEDULE- O a ▪ 1 i FP-9 -----, M - - j 111111111111111111111111111111111111111!!I IIIIIIIIIHIIIIIIIIII Q f .. i FP-20 1 1 --Ti I l FP 3 SERVING A5.02 � KITCHEN y i_ �FP 15� 30" X 48" ACCESSIBLE CLEARANCE. 1 'I I FP 7 FP-20 FP-8 W M FP 1� ( 103 �_ r � V r_1105 ) FP-7FP 8I FP_1 GOORD TOILET ROOM FINISHES AND ACCESSORIES WITH INTERIOR TOILET IC OJ N1 i FP 4Fil 1`,, l ``. .'-�i A5.02 JI 1 FP 8FP 5I �'� N3 � I I I FP 2 Q ELEVATIONS AND SCHEDULES.II I . I I i FP-14 FP 2 FP-13 I - < jI I II ;'_- _z_x,:��. r-�1� I 1F ` n I FP 8 FP 2 I 1 L JI► �-a; °11 -'-� € F P 1 1111 FP 1 I !FP-1 ALL WALL CORNERS IN DINING AREA/HALLWAY TO HAVE CLEAR CORNER GUARDS, 48' I I t`, II Li - K r — — — p \� Ol rr P 20 t. -_. _fi _ ;' l I 4 N 7 ,'1 I L-" - 11 1,= a ii�s�,� F�.... .t LONG; PROVIDED AND INSTALLED BY GC. 1 til-' 0 IC fq �•..,,� Jf•�r9P����' -rte ■ I I- f f-^t: V ?I t �J 11 ill i1 11 II IIL JM } - H 1.0+4.it 1";r 1= _ _ ♦ :ouu::u�uuu�acnw:a,u...-...n O 'i i II •*5--=' ihHIGH� l,.'' .'7-0077-7-1t71., -;;Lis_" N ': LJLJLJL� �L � 1111 M,.,N 125 (�� `+ �Iliillllli�l�li1111111�lallllililllll Illi) 1,111'11111111. ii 0 FP-1 NEW BOOTH SEATING / BOOTH WALL BY MILLWORK COMPANY AND INSTALLED BY THE : W z v1 ,0162k / q. �_._:Jr▪ ' ----. 't N � ];:. {< ---- yr�.� STATION 1 ® Ce I6 \ J., HAIIR ':i"y ' , 4,- __ _ir _. ii-ir • _ 'II �111100lll !1 I <FP-22> GENERAL CONTRACTOR, REFER TO MILLWORK SHOP DRAWINGS. w z ❑ - FP-19 LINE OF FLOORING TRANSITION. COORDINATE WITH FLOOR FINISHPLAN SHEET AI A I. _--_ .. . . . .. .. .... I �� 5 EE 03. N17I— U I FP-3 FP-3 T �. �� z ill FP 20 NEW COUNTERTOPS ARE PROVIDED BY MILLWORK COMPANY AND INSTALLED BY THE r••_t Q 1--I 26' I � - GENERAL CONTRACTOR. COORDINATE ALL REQUIRED SUPPORT POST LOCATIONS WITH I I- 1 I MILLWORK COMPANY'S REQUIREMENTS. REFER TO MILLWORK SHOP DRAWINGS. tJ'1 • FP I '-4" -II" 2 OPTIONAL WATER SOFTENER. WATER TO BE TESTED BY THE GG/PLUMBER AND 3 33 / / // I I / DETERMINED IF WATER SOFTENER IS REQUIRED. O -I <FP-22> NEW ELECTRICAL PANELS WORD WITH ELECTRICAL DRAWINGS. 1�I O '14`-8 �' --- ETU _ — _ <FP-23> AT EXISTING DEMISE WALL INSTALL 5/8" "SILENTFX" GYPSUM BOARD / J / MANUFACTURED BY CERTAINTEED FROM FLOOR SLAB TO UNDERSIDE OF CATWALK ABOVE G.G. DECK ENTIRE LENGTH OF HALL TO VERIFY IF ACCESS l • _ DOOR THRU SCOTT ' TRADE DEMISING WALL .. I HAS A I HR FIRE RATING, MARK: ISSUE: DATE: CATWALK IF NOT INSTALL I HR • I FIRE RATED DOOR AND GENERAL NOTES.• Review 50% 01/18/16 FRAME WITH CLOSER. Review 90% 02/05/16 Property Owner Review 02/23/16 II_ PATCH ALL EXISTING GYP BD WALLS THAT ARE SALVAGEABLE FOR REUSE TO A Permit Set 03/11/16 LIM IIIMINIII CLEAN UNIFORM APPEARANCE. REPLACE NON-SALVAGEABLE GYP BD ON WALLS EXISTING TO REMAIN 2. PROVIDE FRTWD BLOCKING IN NEW AND EXISTING WALLS THAT REQUIRE NEW CHAIR RAIL. PATCH EXISTING WALLS A5 REQUIRED. FLOOR PLAN 7". ...)1txt- SCALE: 1/4" = 1'-0" NORTH PROJECT#: 15085.01 DRAWN BY: ON CHECKED BY: DJB Arkinetics,Inc.and their Consultants shall be deemed the authors and owners of their respective Instruments of Service and shall • retain all common law,statutory and other reserved rights,including copyrights.The Instruments of Service shall not be used for future N additions or alterations to this Project or for other projects,without O the prior written agreement of Arkinetics,Inc.Any unauthorized use of the Instruments of Service shall be at the Owner's sole risk and without liability to Arkinetics,Inc.and their Consultants N arkinetics©2016 W DRAWING TITLE: n FLOOR PLAN xi 0 0 70 v rn xi K -=I M SHEET#:Cr) 8 A1 • 01 o r-II-N\ K---....2_-) \ I I I : 0, 4 1 = ♦ Ova MI . f . S. • i LI E ... ♦� , / 0 .� I KEYED NOTES: I I 7'-Z' 8'-b" 5'�' ICO" b'-II" �\ F1<-17.> NEW FLOOR. MOP SINK - COORDINATE WITH PLUMBING DRAWINGS. SEAL I ' \ ,,, 1/4 t t . 1 flf- il f f '‘‘,). : __ .... NEW FLOOR RAINCOORDINATEIT i p � -�1 t�� PF , , _ _ ,_ 41.--i.--14 - -.71 I �, - NOTE: DIMENSIONS INDICATED ON PLAN FOR LOCATING FLOOR DRAINS SHALL ' � I �' _� . --1 _41----L--I----,_L_11---��--i+--- < ` r , © EQUIPMENT a_ �� Iar� ,r -�- "' ' ' II"'' - IBE VERIFIED BY THE INSTALLING CONTRACTOR AND THE 1 n • `' ii _ I1IifiE r rt :icti- ,. a, 0 �i IIIIf� k 'FP 3 ��. -.'-'1-)L--. 3. , II II @ i i 1 II II ' I11 tr It I `IIIj'I' '� •Ma-1r,si v. ..... 'III • f C I r I IL 1 ' oral \ FUR COLUMN WITH <FP 3J NEW WOOD CHAIR RAIL, COORDINATE WITH DETAIL ON SHEET A5.01CO } F 2 • ., II I r - i - 1 FP 111 0 GYP. BD AND ai �n o r _ FP 3 FP-6 <FP 4� NEW COUNTERTOPS ARE PROVIDED BY MILLWORK COMPANY AND INSTALLED BY o0 0 U) r p I I ligi .� METAL STUDS 1 `� `� 1 �- - 1 � FP 2 i - THE GENERAL CONTRACTOR. COORDINATE ALL REQUIRED SUPPORT POST '= r V ``� to :71 Q. SEATING AREA FP-3 € 1 -`� MIN m v 10 01-r0 �I it?' �� '�I I 11 I U LOCATIONS WITH MILLWORK COMPANY'S REQUIREMENTS. REFER TO MILLWORK M EN g Lr. p N N ( , i 11 FP 4 ( _ I k K��.._I I MENS �� _: F.D.I I _ ,L-f € + I I SHOP DRAWINGS. O N I 1 I� I L Ju �_� �_� _ I L-_a--J I 107 J TT 1 •' • I r ----T- __ _r---- = I I 1 I i o IP i I--I 1-I- -� I' I I 1 I 1 1 = -y _�..-,.Y_x b'_6„ Ill NEW IX STAINED HARDWOOD TRIM PROVIDED BY MILLWORK COMPANY AND _ I ---- --- ----i vI _ I I OME � I I I I ip f - W NS l: • I I FP-5 INSTALLED BY GC - COORDINATE W/ INTERIOR ELEVATIONS AND FINISH SCHEDULE. W L. , OU J ES -I 0- LL lio..,1_1111r ter ' 1 I - I' '1r 'I n77 1 i : r ( 106 )r 1 I I I 1 11 I I ; , I I rl I a_ tTk f y I �w �P-1 Nr- -y�J FP-7 ,: li I I 1FP-3 " rn CA _ �I'-` �ig-'I i I fl i i I' II i 1 f, 'l '"144.4'''.;-1-.' I< HALLWAY O ,• �, j NEW QUEUING SYSTEM PROVIDED BY MILLWORK COMPANY AND INSTALLED BY °' 0 : .: I 1 I I ~ _ FP 6 = U) IL .a-=' 1 - �_� �_J I 1 i II 11 I L-I-'-i ( 102 F GENERAL CONTRACTOR. CONTAINS I /�" POST (GORE DRILLED). VERIFY WITH cp 1 1'' I I I =� ..: 1-, l' _-.i,--)E 1 • a J ;I . cn --` r-r1 _ .`� _1J--7-.,:•7i1=--,----41.7.--,7-74.-471_ -- � !': ►�►'�1 , I _... ki i K1 L F i SHOP DRAWINGS 8 INSTRUCTIONS. (� Q C L It_- } _ FP 6 -,. I - - 102 - L` FP 6 - 1 - --- �� n I I ? I d l-i _• ,..!I ` i FP 7 NEW BOOTH SEATING/COUNTERTOPS WITH SUPPORTS ARE PROVIDED BY c (T5 �'-4` 3'-3' _ 3'-O " L — n J ; 1 MILLWORK COMPANY AND INSTALLED BY THE GENERAL CONTRACTOR. REFER .11(1:9 p r 'I-2 . 1::: EXISTING CATWALK 1 1 g AA �`-O" q ,. ��-�3/4" II'-10" FP-9 in 13'-4/4" FP 6 FP 3 ` 3'-4" i7 ABOVE TO REMAIN TO MILLWORK SHOP DRAWINGS .: o . ,6' 7> - __ -- - R'F i r- a lr : WALK-IN FREEZERI I j I 03 CO dJ 1 _ FP-6 FP 6 FP-6 _ (FP-8> 6G TO PROVIDE AND INSTALL (I) LAYER OF NEW 5/8" FRT PLYWD SHEATHING J o i FP 2 'II1 15'- / ,-/--- I FP-2 I i I 3 1 FROM 48" AFF TO ab" AFF AND (1) LAYER OF NEW 5/8" TYPE-X GYP BD ABOVE p CC 0 '- I:- 2'-O' II' 4 O " 4 O E'-b' 4 Om ai cri \ l' / I -b FP-3 I-I�_�/4- I q,_8" ! I j AND BELOW PLYWD AT THE DENOTED PORTION OF THIS WALL. -(5 ,t U CD (D FP 6 FP 6 "v FP 9 NOT USEDM :44: m ° _ - QUEUING K> > F 11 ( -' I .. — °' N _ _ ! i U PROVIDE AND INSTALL BLOCKING AT DIGITAL MENU BOARDS PER Q (O U a e . I I I. I II fP10 lir IL ..i - :._L AI .„.,...;,,-A. ::_. ,_,:_= -,-::_ __ -: -- --- r` MANUFACTURERS REQUIREMENTS. III is ' .14'I I 11 FP-4 ,...... r'i >=s .... I I JLC _,3, t- II - - - , • ; i1 E i-I- "' 1 1 . , , . i; i1 .�� 1 11 �� Q _ P 1 GG. TO PROVIDE PLYWOOD BLOCKING FOR PLUMBING FIXTURES AND I1 I , 1� E i h 1 _ I IT ri i I1 I II 1 ;, ;r •N I II 1 BATH ACCESSORIES CONCEAL BLOCKING WITH " MOISTURE r I rte - V --- J LL- ——'—' ,J r� �� € 1 LL k_.� .__Jll I FP 5 1. i_ 'cv ;", ; ; — -_ ——_._..__— ----_ W k RESISTANT GYP. BOARD I-i1 .1_-i 1 11 3 L____ 1 3 FP-2 , ,{'Ir I HI _II _'-5/4° I 1 23'-7/4" '; `: 5'-q" 'I1 1` t A, ! 1 - Al ` PROJECT: !1 I i , ii i SERVING KITCH FP 21i 1 hl-JU i FP 4 ( 103 ) �� ( 10' ) 11. /4' \ ❑ IW , , FP-3 1 I ;4 C:1 11 (FP-5 i I ���� / iI ® Q ' , s II Af - I rErb. r W-14 1 - O 1 LLAi W-1 —1 1 F.__ -_- _- _7r___ --71 — r- i- FP 2 1 t ( G I= 1_. 1 I 111 N ' Il I€ �,a11 1i ki —� m �� Ilq G-1 3 ,_ -a r� 1 I io p !� li €[II�III 11 11 f <FP-1> rw.t :1;1 - }I t � _, ���■ 1 I Ii€ I€ ! it €[L11 i 11 ?y ll' ryl� �i Imo`'e _._. i i11V j' I II lil '`>_ , i��, -- I -- - €i 11 " rf - jn - -- i•� ��- 1 . , I 0 w L 111m i �'y T t I� I 1E1+,.-. -ii7�j 1€LF] 11 i If MAN��; S r el t .1 •... I 41 O T� 1 I 1 R _ �� FP 2 mom i.. I I, I; r ---4-- 5rwr1 Ili I I (� 1 el el 1117 x • • A 4'-0" .1,_/4„ II:--k4• 13,-�4" 1�,_4V4" 4'-6" FP-8 -5=13/4„ ,I,, 5'--2 4„ -,.2" .5'- F:' 4,_0„ I ! �.y.� Q t1] n / / Z6'-II' P 10 // FP 4 II'-b"�FP 8� / I // / zu4iito N ( Z • 344 FP-1 r w Z O O I ' I� / O Z ❑ \141Z i_ 1-•-i f:i �r1J - - - Z Q l7 1. _ F- FRAMING PLAN v) SCALE: 1/4" = 1'-0" .01H. 111Hill rA- y CD C3 NORTH METAL STUD SCHEDULE MAX LIMITING HT AND NOTES COMPOSITE WALL: NON-COMPOSITE WALL: WALL CO M POR ' " 'SES GYP BD FULL HEIGHT ON GYP BD 6" ABOVE ACT 35/a" MTL STUD KICKER BRACE PLACED BOTH SIDES (A) OR FULL HEIGHT ON ONE Nolo.L ON ALTERNATING SIDES OF WALL AT A 'ADDITIONAL HALL SIZE GA MIL TYPE SIDE (A) MARK: ISSUE: o DATE: 48" OG, MIN 2 PER WALL. EXTEND AND COMPONENT - SEE BELOW. (E) Ib" OC 24" OC lb" OG 24" OG Review 50% 01/18/16 WALL TYPE TAG - I Review 90% 02/05/16 ;p FASTEN SECURELY TO UNDERSIDE OF DW STUD ` STRUCTURAL DECK, BEAM OR PERLIN GOMPONET Property Owner Review 02/23/16 . .I .D COMPONENT NOTE/pESGRIPTION 25 15 5(g} 13'-4" II'-8" 9'-3" 8'-I" ABOVE. LETTER �° Permit Set 03/11/16 INSULATION OCCURS FROM FLOOR SLAB TO MIN 6" ABOVE 20 Iq 5(B) 14'-4" 12'-6" 10'-I" 8'-10" 1- 1—�I W CEILING MAY OCCUR, SEE PLANS OR A 20 30 5(B) 14'-cl" 12'-11" 11'-10" 10'-4" Q Di , zd FINISHED CEILING. ! SPECS FOR INFORMATION ON GRIDTO DECK ABOVE. DW STUD w z CEILING MAY OCCUR, SEE PLANS OR I z CEILING MAY OCCUR, SEE PLANS OR -' 'i TILE AND CEILING TYPE AND MATERIAL. B INSULATION OCCURS FROM FLOOR SLAB ,SLI SPECS FOR INFORMATION ON GRID, TILE ,v Q SPECS FOR INFORMATION ON GRID, TILE IL G MOLD/MOISTURE RESISTANT GYP BD ON HET WALL SIDE. 25 15 5(g} 5-b" 3'-7" 12'-4" 10'-7 . -I d AND CEILING TYPE AND MATERIAL, AND CEILING TYPE AND MATERIAL.• 20 Iq 5(B) Ib'-4" 4'-8" 13'-I II'-10" LL's. z z N v 20 30 5(B) IS-6" 16'72" 15'-9" 13'-9" w - Lu. - 3%8" STRUGTL STUD In 4r GENERAL NOTES: 20 33 5(B) la'2" 16'-9" 1b'-3 14'-3" 418 43 5(G} 19'-I" Ib'-8" -- - -- (U LAYER %$" TYPE-X GYP BD THIS SIDE (I) LAYER 54" TYPE-X GYP BD TH15 SIDE (I) LAYER 5/g" TYPE-X GYP BD EA SIDE I. PATCH ALL EXISTING GYP BD WALLS THAT ARE SALVAGEABLE FOR REUSE • OF 3 %8" MTL 5TUD5 AT Ib" OG. TAPI=, 6 54 5(C) 0-6" 17-II" -- -- OF 3 5/e" MTL STUDS AT I6" OG. TAPE, OF 3 54" MTL STUDS AT Ib" OG. TAPE, TO A GLEAN UNIFORM APPEARANCE. REPLACE NON-SALVAGEABLE GYP BD. __ SPACKLE, SAND AND READY FOR 14 68 5(C) 21'-11" lol-_2" SPACKLE, SAND AND READY FOR SPACKLE, SAND AND READY FOR ON HALLS EXISTING TO REMAIN • FINISHES. SEE PLAN FOR LETTER "C" IN FINISHES. SEE PLAN FOR LETTER "C" IN • FINISHES. SEE PLAN FOR LETTER "G" DW STUD • HALL TAG INDICATION, SEE BELOW. �'� WALL TAG INDICATION, SEE BELOW. IN WALL TAG INDICATION, SEE BELOW. 2. PROVIDE FIRE TREATED HOOP BLOCKING IN NEW AND EXISTING HALLS THAT 25 15 5(5) 21'-II" Iq-2" -- -- REQUIRE NEW CHAIR RAIL. PATCH EXISTING HALLS A5 REQUIRED. 20 Ici 5(5) 24'-0" 21'-0" -- - -_ PROJECT#: 35085.03 1 20 30 5(B) 26'-5" 23'-1" 23'-3" 20'-11' SiTRUGTL STUD 6" DRAWN BY: DN CHECKED BY: DJB" SOUND ATTENUATION INSULATION, I �'-4" -I " 20 33 5(13) 2 23 0 24'-I I" 21'-I" .s MAY OCCUR NO VAPOR BARRIER. SEE I '4611 43 5(G) 28'-4" 24'-q" __ __ Arkinetirs,Inc.and their Consultants shall be deemed the authors PLAN FOR LETTER "A" IN WALL TAG and owners of their respective Instruments rvi andshall s : P • 1. ofService s a INDICATION, SEE BELOW. I6 54 5(G) 30'-5" 26'-'1'' -- -- retain all common law,statutory and other reserved rights,including 4 ('P, .+(55((51j(1.172)! G) f_-�f 28f_b f __ copyrights.The Instruments of Service shall not be used for future N -- additions or alterations to this Project or for other projects,without O CONTINUOUS 35/8 MTL RUNNER, FASTEN CONTINUOUS b" MTL RUNNER, FASTEN CONTINUOUS 354" MTL RUNNER, FASTEN FOLLOW NORTH AMERICAN SPECIFICATION STANDARDS: the prior written agreement of Arkinetirs,Inc.Any unauthorized use C SECURELY, MAX 24" OC. SECURELY, MAX 24" OC. cA the instruments of Service shtea be at the Owner's sole risk and SECURELY, MAX 24" OC. (I) UNNER TRACK GA TO MATCH STUD. without viability to Arkinetirs,Inc.and their Consultants 171 N BASE A5 SCHED. :1i BASE A5 SCHED. BASE AS SCHED, (2) zR ALLS OVER i2-O HIGH TO BE LATERALLY BRACED;VERTICAL WITH arkinetics 0 2016 CO .i " Ib GA GOLD-ROLLED CHANNELS CLIP ANCHORED TD METAL STUDS FINISH FLOOR A5 5GHED. FINISH FLOOR AS SGHED. FINISH FLOOR A5 SCHED. OR 41200 SPAZZER. DRAWING TITLE: L7 Alfi (3) DIFFERENT LEG WIDTHS MAY BE SUBSTITUTED TO REACH HIGHER Ali STRUCT FLOOR STRUCT FLOOR WALL FRAMING PLAN T TF R HEIGHT LIMITS GG TO SUBMIT SPEGIFIGATION5 FOR APPROVAL. S RUG LOO 73 O NOTE: NOTE: NOTE: (A) BASED ON CLARKDIETRICH - PROSTUD SERIES INTERIOR NON-BEARING 0 SEE FLOOR PLAN WALL TAG AND WALL COMPONENT NOTES SEE FLOOR PLAN WALL TAG AND WALL COMPONENT NOTES SEE FLOOR PLAN WALL TAG AND WALL COMPONENT NOTES PARTITIONS WITH ONE LAYER OF GYP BD EACH SIDE (HT VARIES);U5E 73 FOR ADDITIONAL INFORMATION. FOR ADDITIONAL INFORMATION. FOR ADDITIONAL INFORMATION. GA AND TYPE AS SCHEDULED ABOVE, UNO ON DINGS, (L/240, 5-PSF). MCDWALL (B) FLANGE SIZE = 11/4"WALL PARTITION WALL PARTITION PARTITION (C) FLANGE SIZE = I%$" -- (D) WEBSTIFFENERSREQUIRED AT ENDS PER MANUFACTURE'S 1-1/2" = 1'-0" FURRED WALL 1-1/2" = 1 -0" FURRED WALL = 1'-0" NON BEARING RECOMMENDATIONS . (./) (E) ADJUST PER MANUFACTURERS SPECIFIC OR EQUIVALENT PRODUCT. M SHEET*: w 0 2 w • CD 0) 0 0 0 C--• I I I 58'-10 ' I I I SEAL 22-b314' 6'4' T-2' 14'-I' '1'-I I' -1 1i P-26 I I BOTTOMC41 OF SOFFIT ,■ KEYED NOTES: ..--22-----,..— _ �i 1 / — ill‘m .- . . . . . . . ••' • II1��i J • ' -• irn"IME =i �:==: ■■M Q �----- c1) : . • III Irl a\iM - 't. .. -I� 11J1MM■:�tr%�Mi �witaimI -m a� o h. : : : .' '. :' '. .' : : : .' '. : :' . Ilr iG'�1►�■ .: 1' !`�I•La�l;�)lil ��■:[�l■1 ® NEW MOP SINK, COORD. WITH PLUMBING DHSS. } a Q Q r A / II--���_ !n �'- .�CPT-2/. --1♦1■� �„�i.• -�\'1/�1 0oo r Q 1. :. IC�����■ . 1 ir-2� 1�[i' P-26 ' _• � ( Cr) LO a) _c cb to : .' '. .' ���7�� . 4 : r` JF��N6'II <FF-2> NEW FLOOR DRAfN, COORD. WITH PLUMBING DWG✓. ■ — -Q Lt. = .t . ' . � Il��li - - il►.11i[ WDF-1 1�)1 ��■it■1 D. O O N N i • .: ' Il�ili P 21 • �Il��u�� � 1 `■� l J <FF-3> FLOOR TRANSITION GOORD, WITH FINISH MATERIAL SCHEDULE THIS 1) '1° o E r .ca cv cv SEAT)NG AREA . .. . : . IIi�1E il,�i �Em r� r L • • • • • • • - 116ii1i. . . • '. - 'I' •• =111117111M1 ��� - ICET. 0 0 '•'.• . •'.• • •'.- • '•'..: -'. '• '• -'.''• '• -'- . IIiL•ii' . '. .1' • - _Ir....r1i1•__ iim'� 0U ° cv J CL LL 111•�li r' _JLLL -O�1 �1•i• ® FF-4 60 TO COORDINATE FLOOR TRANSITION TO + Cn .is'. - . . - . _��t_ _ _ r J OCCUR BENEATH MILLWORK WHERE APPLICABLE. II•i1�i . a . • . . CPT 1 u1 1• ) BOTTOM \7���►� 1A11■li1Rll WINE* 1) I 10 r� ��' '�■ ilIF��u�iv�� - O Il�ali 1•■L �i� 106 >•1•� - ■ E C � ;. ' CPT 1 •- ' II�i�. � P 21 CPT 2 n� ���iH I c �C ■� ,i2Ji\ MINI/ I � .. MinrnMin ' • - - • . ' • . •- • • . • • • . • • ' . • ' - 11 0=• • • . • • AD . • • • . • . ' . �� ■i P-26 v-- 1•�..■.—•► .� --• • I .� . _.. ..' � m FINISH LEGEND. 0 .E l �lnkil�%MINiMONMMI=1�6fiiiNIMIWI MEdl l kl d I �)!■1W�l� 11 11M111i��i1i►®i��iI�li►-_M��F _ JcT_ o' 0 0 �.�....• ... o 1 co co !A: 1 — �' ( 10X ) GOow. WITH ROOM FINISH SCHEDULE ON GREET Ab.a O - ImoiJ1�1� ����1•�1•� mi1IY �1•�•Iti�mIII i T-s- 0 iii•■����!•���������1•��ii������i1■ 1 -�I-�� a) c `.) c r� I �I•i�IIMII ti•��� WDF-1 iM-MI M WDF 1 11111111111=WI3F-1 i -4 a� m r- 1•�ii■mp--. Ld��i� rr�li �►...�t P-24 .=II•� FRP-1 IIIII ¢ > > c� N �Y�`_- P 20 UIW. .I .. jjd111I I ` U c U LI: im�i•l � m� I��Iiri1•.-_�Z�,0.=i!1J3� dim■mmimmi mm ii 1,®�!1•i/iMai: 'J.-i�1�101MIMIEI LL�7��� .■-■-■■ . 'C. I INNI61101111111411111111111111111211111111111 ME 1111.111111 g .11�1•..i !!• ifl"iimi 111111 I f":" A MEMTDIMME �i►is1•�F����� ■■� I. ii!I 1 P .■�■��� I O PROJECT: BOTTOM 1EU!UIL -----■■..-..11 1 1IAl Q OF SOFFIT /OIWAM--.1 1i1•=1i1•�' -11M ► . P-20 -_ 1 ■�iI�I�IIEML. 1& MIE12111111.16WAN.Elk.441 1111 WDF-1 J P-274 / 1 n l.ilTiii��ii�i►i7 1 FRP-1)-- OW/M/ IM ! - 2 OF opilifillii,ur r ■iiIM1� �1ii►Ll %r111M =LIM•ME•'-�- ME= -- IPI - LU D m (-1--3) , F1=mm•mmI MNIIIMMIMINIIIIIIIMMI i73ENNi1i6fl•'•1 �— IIS■■r�119��\ ■ll!_1 �■■ L'L:S- ■ ;;�! ct a •— -------momft, Irl z c3-) o- 1 1:44A , 47 g 0 ir2 13'-10" 26' 2' 34'-?,V4' 4, �; ) w z L.6 0 / /1if nook $ CC / / V7 C7 V) Q IRTU _ _ _ ---1 FLOOR FINISH PLAN , Q SCALE: 1/4" = 1'-0" '. Ail , / C) 7r r-1 NORTH CD FINISH MATERIAL SCHEDULE FINISH MATERIAL SCHEDULE LOCATION I CODE I MATERIAL I MANUFACTURER PRODUCT NO. DESCRIPTION/REMARKS LOCATION CODE MATERIAL MANUFACTURER PRODUCT NO. DESCRIPTION/REMARKS MARK: ISSUE: DATE: CPT-1 CARPET 544WCAF FETIFATCRAF•T ZCFFI SND ZIP IPCPTTL 24'X24", IASTALLAT1CN: WIRIER'LW Review 50% 01/13/16 FRP-1) FIBERGLASS REINFORCED MARLITE P-118 ALMOND KITCHEN AREA - Review 90% 02/05/16 POLYESTER PANELSAS NOTED PLEASE FURCI-66EE ALLELLF/A0-EE`vETi lkI _ Property Owner Review 02/23/16 0.61-CM CAST 111E STYLE 1*DICT PATCRoFT FEST MANF. T10+B ® CERAMIC WALL TILE DALTILE RITTENHOUSE SQUARE: ALMOND 0135 GROUT: MAPEI FLEXCOLOR GQ CCLCR T G-0 Permit Set 3/11/16 RESTROOM WALLS COLOR: WHITE 00 015536MODIP4 - 5X6 TILE CCMrAGT: CRAFT 01355436VODI P2 - 5X6 BULLNOSE NAT1GIA-ACCQ.MS S.FrZ':RT mei< ' ' 'G f�� �22b, IME 4J � DATO 0135A3601IPI - 6" COVE BASE B NAT1 TTLE1CO PATDALTONt 4 P: 8Tf 28 OR 24x..0 3408 CZTGM�CELT: (EGO)241-404 ACCENT TILE: KEYSTONE FCR AEOSTANE NTH FRC=AVALABIUTY, VCE1LE F )23-4654 031111MSIP - 1X1 MS DSII BLACK SFECIAL FFICIIO, INT73d+LAl1CNAL 514.15 CR TO DAL: KYLELLNA IBPATCRAFT.CCM 5.15MT A FIRCA44SEC — ITEMS: VIRGINIA TILE: STEVE REINIG CPT-2 CARPET 94411 CAWET/PATCRAFT ZCUF1 CR3ER ND T6SELZCLPCPT EL FLEAEE1 F6aEE,`V1e74.1E/ALl-EYETFfO.151-1 CERAMIC WALL TILE IN CTI #50155 ZOUP bX24 FIELD TELE - 11.645F/GTN DIRECT LINE 248-41 -7850 X2335 PATCRAFTFERMAN!. TlaG ® SERVING AREA AND AT CTI #50156 ZOUP 12X24 FIELD TILE - 15.52 5F/GTN 10331T AEGCW�C5 MOBILE LINE: 248-388-6440 STYLE: BEVERAGE COUNTER CTI 0;50151 ZOUP 6X12 COVE BASE - 12 EA./GIN EMAIL: ZOUPTILEGSMAIL.COM FEJT-CR/ONCE EIROF'° CCNTAGT: HYM BRIGS 25 - HYDROMENT GROUT KYLE LLNAJ CF PATCRAPT HYM - COLOR: BRICK - SANDED GROUT 254$ BAG CaLR R COTS KEl'STCNE FO DR2443R 228,PA-TON G4 30122 P-20 PAINT BENJAMIN MOORE HC-160 KNOXVILLE GRAY OSTCMER.CQJ+ECT: (WO)241-4414 AF VE: 3500 9-66+Ni EEl.CiJ.E, MALE: ( 6)235-4634 PRpJECT #: 15053-01 P-21 PANT BENJAMIN MOORE 2112-10 COPPER CLAY SECO M`-E EMAJL KYLED,f WJ®PATCRAFT.CCM P-22 PAINT BENJAMIN MOORE 215&-20 VENETIAN GOLD FLOOR _ WALL - - -_- (WDF-1) VINYL COMPOSITE PLANK PATCRAFT ZCLIFI CFCER ND 120:A/=LP\ANI- FLEAEER ALL LE/A vE11-PAC k DRAWN BY: DKN CHECKED BY: DJB ( P-23) PAINT BENJAMIN MOORE READY MIXED NAVAJO WHITE FLAK PATCRAPI FEFt MANX. 1105 Arkinetics,Inc.and their Consultants shall be deemed the authors and owners of their respective Instruments of Service and shall P 24 PAINT _ BENJAMIN MOORE HC-81 NORTHAMPTON PUTTY STYE 12CV1I-1C-3-LAW FST CGMACT: retain all common law,statutory and other reserved rights.including copyrights-The Instruments of Service shall not be used for future P-25 PAINT BENJAMIN MOORS 2114-20 BLACK-BERRY GQ G2 2 W°LNJT KYLE Ll hIAJ CF PATT additions or alterations to this Project or for other projects,without r/ P-26 PAINT BENJAMIN MOORS HC-21 DUNMORE CREAM WA 4'DIV 2�DA-TON G- k 57122 the prior written agreement of Arkinetics,Inc.Any unauthorized use \ N YEAR!AIR 20 ML 0.. GQdCCT (.5009 241-4614 of the Instruments of Service shall be at the Owner's sole risk and C P-27 PAINT BENJAMIN MOORE HG-I4 NORWICH BROWN t L E ( )255-46E4 without liability to Arkinetics,Inc and their consultants C -0 -------.. A VE 410,9454^1V1411-FLAW W AAV 1�WIL IMJ EDM BPATCRAF.CCM arkinetics 2016 N ( P-28 ) PAINT BENJAMIN MOORE HG-TI HASBROUCK BROWN 11L E OLLE - DRAWING TITLE: to ( P-30 ) PAINT RUST-OLEUM FOSSIL - SATIN FINISH CID VINYL COMPOSITE TILE PATGRAFT ZO.PI CF N? maw zar\ANILTL 18' X I8" G STAIN ML CAMBELL MLC CHARCOAL AFTER STAIN 15 DRY (I) COAT CLEAR STYLE cry/ ,TE CCN1ACT: FLOOR FINISH PLAN WOODSON6 II W52-5125 SANDING SEALER 4 (2) COATS CLEAR yGGLr.R 03620 SNEET KYLE atsiv OF PATCRAFT X] SATIN FINISH, SAND BETWEEN COATS WITH FO LAY R 22e>,DA...TCN Gat 50722 CI ® CLR. COAT POLY FINISH SHERWIN WILLIAMS V84F82 320 GRIT 0 41Cr?Si�W VINYL FLAW.AAD UbTG@Z )241-4Ga4 111.E1 1r NM-6 (5e6)Z5-46134 B4L K`LELLtAIPATGRoFT .C.CM M MD TRANSITION 5TRIP JOHNSONITE BROWN 110 CTA-40-D, USE AT CARPET TO VINYL TRANSITIO SHEET #. com w A 1 • 0 3...., 8 a y Tl , ,. C 2 ) \ l 1 1 / 0, • \ I 4-... )\. ci. + • ''' _ ri N / f--�_-/-1 v soli .. 1.0„, ,,,, , ` D , /// 1 •• SEAL / i ' \ % 1 , _..Iil u-7•77-7-77- . " � _ -.. 1 . - ._ -._ ._.. _ _ - . 1C ;I 1 I II t N II II II ��1 �I i �1 l t._. �I l+- 1 _II lit_ II_.1 -� `' - € -, F.D. L_1 I II r' J J. I , Illi _ N I L1 ,„4k--...,...,•,,,,,2,i N -II llr I ? �l f� 1 ]� • nll _� I -�. a, I 1] I I I I I I. I 1 1111 9 ".'�' f,: "." I +-' 1 1. r JI1 lL , ..N r: ..,. _ N I N �� 0 la a) N I CD :):::ii4ire2eZga7- �(J 3 II .I0 .1=J 0 C+6 •C3 ,9- ZS 1a SEATING AREA f---�"� O ' i cf.. TID_IIIIIIM:.. 1 I I a c� U c� co1 �� 11- I .' I ■ -2 OILN 4i 1 � ( 100 ) II MENS O NF:D: Ni t._.. � _ = IL_Il X107 ) • - . � � � 00VV 11114111 .1I n---- ---r-- p I WOMENS c,z, _ f j� 0 0 > 0 '6 n: u.. r;h j I I ` k. i s I €�_r: •Ted ( 106 ) - --�.- �J 1 - 1 I N 1 �1,_. I N fl I i I ] rnl_1--� L I» � I i HALLWAY a--- WAMIi I }V-r �I .:x.... ,Ii �c� -� 2 1 -1-r-� •-2, r•-,,t----:' . ( 102 ) 4 i 1 • _ i Ili II rk� �-- -- r .,. _ 1- u�� 102 r, IIICJ I L . i 1 11i II L J ^� ,... _ _ . , , , „,,, m : 1. .. IL .._.._y ra m ,•nG an'. �i ....................„... _ __. ... 'f 770 . allMt ..S 1 . 1 -111111 ", °Ilk MINIT", Imm3.1 .ILII6'.E. ' 0 ;i: ir li-gEg.:1A== \ ali) - . 0 gi 5 0 as 0 o _i•=__ ' I ® ®. Oma,: _M =--:::*,..__ ' -� -� v v c . c l'•-• 1"-- ! 1 I 1M WCDCOa Coco I GI QUEUING ��I� :� .� cANeT ON wleels eeLow/ID N I _ .. Tilr 7 N N o= , r.1 �1 ( 101 ) l: I�- „ wI SIN(DRAIN WARD U N 44 ss GAL. II I : -,, I II t ARSA6E - Q f1 f.L .4 � . : _ �, - > �i - , .r__1 GANji‘ p I W 1.. N II I c� ? I I JL -r - 1� I :E=I # � III i• I Jo o ; ., ssimer0 CD ImIE ,.141.31L �' N E N II a a y J I ( �. r RACaC I1 l!sn'''1Ii _ ...r_i, , i,_ „ .. . , _Al . : ' , 1 -:Err I ? l o® �' �• ' n PROJECT: _JI -� o0 00 0© N3J 5 6 _ ABOVE DESK- e ° 0 m ilii _, •5,_,e - M ; 1 © 0 SERVING O �� KITCHEN 4e �� M +-- i . 0 7 0 le ( 1,4 ( 105 ) ® ® 0 0 © cF+s=MI(1D I '\\J I' O I�® � � 7 L1L'EI OCD, 0I 16.2 joke p®© (-rico ,„,,, I 0 a , W 0 ie) 0 Ce ;II__ � o L1JI �� SII -- -- 1 1 11. 1 II i; ■RR1 1.- 2� d it r # ta" �r tl � p7 {40111111M J ®r � pnel , oc it d `-`--• I ��;:. I! 1. + MA R 5 II 1 a , �� I�����I��!IEEi�li�hl���■ 1 `...J-�� ` - :.... I I li �r.__ �I' i� raaaaa_r 1 1 i .r �r - Y _ STATION .111NJ1 i I � � � � �l I .. ,1 I �*'*■[��!_-,,,,i,-,..1,1,--1u11111�J�1��1 " -. ems: ,�t � �� _ - 7 ..... _� �:_�- - fI = ,. -_� r � -� • W NNW CHAIRS - * Tt�R • r 2I I cn I • 4. \ cN 5, z EQUIPMENT PLAN • 1* V)"' p • z t..5 SCALE: 1/4" = 1' 0" : ,,,,Q - o o z ❑cc Qn NORTH z Q EQUIPMENT SCHEDULE EQUIPMENT SCHEDULE Q GAS PLUMBING ELECTRICAL GAS PLUMBING ELECTRICAL Q EXIST. NEW TAG QTY MAKE MODEL DESCRIPTI❑N REMARKS BTU SIZE HW CW WST. HP VOLT AMP HGT, EXIST. NEW TAG QTY MAKE MODEL DESCRIPTION REMARKS BTU SIZE HW CW WST. HP VOLT AMP HGT, O • 1 4 OWNER PDS MONITOR 0 • 21 1 EL-MUSTEE 2424 MOP SINK FLOOR MOUNT- BY PLUMBER Co O • 2 6 OWNER PDS PRINTER 0 0 22 0 TABCO DUN-2448-2X ALUMINUM DUNNAGE RACK O • 3 2 KOALA KARE KB101-00 VERT. BABY CHANGER _ 0 • 22.1 2 _ TABOU DUN-2036-2X ALUMINUM DUNNAGE RACK O 0 3.1 0 KOALA KARE KB200-05 HORIZ. BABY CHANGER 0 •• 23 1 CHECK PLANS CHECK PLANS WATER HEATER BY PLUMBER O • 4 1 MESA MFL3020EE 30" X 20" X 20" SAFE INSTALL BY G.C. 0 • 24 1 COKE VENDOR TEA SERVER BY VENDOR O • 5 2 DUKE E303-25SS HOT HOLDING TABLE - RH DRAIN WITH CUSTOM ADAPTER PLATES 0 0 25 0 UNIVERSAL 1N2430-LD24 _PREP SINK 1 BOWL LEFT HAND DRAIN BOARD O • 6 1 STAFFORD SMITH CUSTOM 12' WIDE WORK TABLE _ W/ CASTERS 0 • 25.1 1 UNIVERSAL 1N2430-RD24 PREP SINK 1 BOWL RIGHT HAND DRAIN BOARD O O 7 0 STAFFORD SMITH CUSTOM FAUX HOOD W/ LIGHT 0 • 26 1 MOFFAT E31D4 CONV OVEN - LH HINGE WITH TRAY STAND MARK: ISSUE: DATE: O O 7.1 0 STAFFORD SMITH WP WALL PANEL S.S. PANEL W/ "J" CHANNELS 0 • 26.1 1 MOFFAT SK2731U M❑BILE EQUIPMENT STAND W/ CASTERS W/ (2) BRAKES Review 50% 01/18/16 O • 8 1 CONTINENTAL SW72-30M-FB SANDWICH TOP W/ CASTERS 0 • 27 4 TRASH CANS VENDOR SEE PLANS FROM SMALLWARES SUPPLIER Review 90% 02/05/16 O • 8.1 2 STAFFORD SMITHBOLT ON S.S. 1/9 PAN CADDY INTERCHANGABLE TO EITHER SIDE OF SANWICH TOP 0 0 27.1 TRASH CANS VENDOR W/ 'NO TOUCH' LID - SEE PLANS FROM SMALLWARES SUPPLIER Property Owner Review 02/23/16 O • 10 2 B❑BRICK B-2620 SS TOWEL DISP 0 • 27.2 2 B❑BRICK B-3942 SEMI-RECESSED DISPENSER BY GENERAL CONTRACTOR Permit Set 03/11/16 O • 10.1 4 SOAP DISP. VENDOR SOAP DISPENSER BY VENDOR0 • 27.3 1 BOBRICK 8-254 SANITARY NAPKIN DISPOSAL BY GENERAL CONTRACTOR O • 11 1 MANIT❑W❑C IY-0504A AIR COOLED ICE MAKER WHIP BY OTHERS 0 • 28 1 COKE VENDOR DISPENSER BY VENDOR O • 11.2 1 MANIT❑W❑C B-570 ICE BIN 0 0 _ 28.1 0 COKE _VENDOR DROP-IN DISPENSER BY VENDOR O • 11.4 1 EVERPURE EV-9330-42 WATER FILTER WALL MOUNTED _ 0 • 29 1 COKE VENDOR BAG-IN-BOX RACK DOUBLE PRODUCT O • 12 1 TURBO CHEF SOTA OVEN NEMA #6-30P 0 • 30 2 OWNER VENDOR BULK - CO2 TANK INSTALLED MY VENDOR _ O • 13 _ 1 CAPTIV AIRE CH CLASS II STEAM HD 48" x 60" CURB & FAN BY MECH CENT 0 • 31 2 TABOO 7-PS-40 WALL MOUNTED HAND SINK W/ SIDE GUARDS O • 13.1 1 CAPTIVE AIRE DU25HFA EXHAUST FAN CURB & FAN BY MECH CENT 0 • 32 1 CONTINENTAL 3R REACH IN REFRIGERAT❑R O • 13.2 1 STAFFORD SMITH WP S.S. WALL PANEL 60" x 48" W/ PERIMETER "J' CHANNEL 0 0 32.1 0 CONTINENTAL BR REACH IN REFRIGERAT❑R - O • 14 1 PITCO SRTG14-3 GAS RETHERMALIZER VERIFY 7' WC 0 0 32.2 0 CONTINENTAL IF REACH IN FREEZER O • 14.1 1 DORMONT 16100KIT48PS GAS CONNECTOR 0 • 33 1 DISP. RITE WLO-1B CONDIMENT STATION _ O O 14.2 0 PITCO SRTE14-3 ELEC. RETHERMALIZER 0 0 33.1 0 DISP. RITE NLO-1B CONDIMENT STATION O • 15 4 METRO 1842BR WALL SHELVING W/ WALL BRACKETS 0 • 34 1 PANAS❑NIC NE-1054F MICROWAVE FROM SMALLWARES SUPPLIER O 0 15.1 0 METRO 1836BR WALL SHELVING W/ WALL BRACKETS 0 • 35 1 OWNER VENDOR RETHERM CONTROL BY TECH VENDOR O 0 15.2 0 FOCUS FF1836C 74" HIGH SHELVING W/ CASTERS 4-TIER 0 • _ 36 1 _ K❑LPAK FZR 7'-9' x 11'-7' X 8`-6.25' FREEZER W/ INTERI❑R RAMP - 3PH PROJECT#: 15085.01 0 • 15.3 3 FOCUS FF1842C 74' HIGH SHELVING W/ CASTERS 4-TIER 0 0 36.1 0 KOLPAK FZR 6'-9.5" x 13'-6" X 8'-625' FREEZER W/ INTERIOR RAMP - 3PH O 0 15.4 0 FOCUS FF2436C 74" HIGH SHELVING W/ CASTERS 4-TIER 0 0 37 0 KOLPAK REF REFRIGERATIONDRAWN BY: DKN CHECKED BY: DJB 0 • 15.5 3 FOCUS FF2448C 74" HIGH SHELVING W/ CASTERS 4-TIER 0 • 38 12 NEW AGE 2503 SHELVING BAR STYLE CANTILEVERED Arkinetics•Inc.and their Consultants shall be deemed the authors O O 15.6 0 METRO HP09C 18"x8"x10" STORAGE BASKET MOUNT TO SIDE OF WALL SHLVES 0 • 40 2 NEW AGE 2561 SHELVING LEFT UPRIGHT and owners of their respective Instruments ofService and shall O O 15.7 0 METRO DD18C SHELF DIVIDERS MOUNT TO FOP OF WALL SHLVES 0 •• 41 2 NEW AGE 2563 SHELVING RIGHT UPRIGHT retain all common law,statutory andatherreservedrights,including _ _ copyrights.The Instruments of Service shall not be used for future N 0 0 15.8 0 METRO HK23C SNAP ON HOOKS MOUNT TO SIDE OF WALL SHLVES 0 • 42 2 NEW AGE 2565 SHELVING COMMON UPRIGHT additions or alterations to this Project or for other projects,without 0 - the prior written agreement of Arkinetics,Inc.Any unauthorized use C O O 15.9 0 FOCUS FF2424C 74" HIGH SHELVING W/ CASTERS 4-TIER 0 • 42.1 4 NEW AGE 2583 SHELVING ACCESSORIES HORIZONTAL BRACE ofthelnstrumentsofServiceshallbeattheOwner'ssoleriskand O if 16 1 T&S B-0231 MIXING FAUCET 12" SWING NOZZLE - PRE SINK 0 0 43 0 TABOO DI-1-10SP_ DROP IN SINK W/ SPLASH GUARD W/ GOOSENECK FAUCET without liability to Arkinetics,Inc.and their Consultants N O • 16.1 1 T&S B-0265 MIXING FAUCET 18' SWING NOZZLE - 3COM SINK 0 5 44 6 SAN JAMAR (2410(18 CUP DISP. SHIPPED TO MILLWORK CO. arkinetics®2016 -.1.c.4 0 • 16.2 1 T&S B-0133-B PRE RINSE - WALL MOUNT W/ WALL BRACKET 0 • 45 2 KELMAR EL/6/18 (6) TIER LOCKER 12"W x 18'D x 12"H DOORS DRAWING TITLE: 0 • 18 1 UNIVERSAL 3N1824-2D24 THREE COMP. SINK W/S❑LID STRAINER (RIGHT SIDE) 0 • 46 2 BOBRICK B-232X24 HAT & COAT HOOK STRIP G"). 0 0 18.1 0 UNIVERSAL 3N1824-2D24 THREE COMP. SINK W/ 15' CONE RIGHT OR LEFT 0 • 47 1 T&S B-0653 ^ MOP HOLDER - EQUIPMENT PLAN 73 0 0 18.2 0 UNIVERSAL 3N1824-2D24 THREE COMP. SINK 1 0 • 4812 NEW AGE 97874 CORNER GUARD O 0 • 19 5 T&S B-3940 TWIST LEVER WASTE 0 • 49 1 STAFFORD SMITH CUSTOM 8" X 8' S.S. WALL SHELF 0 71 0 0 20 0 TABU' KLAG-303-X 36" LONG WORK TABLE W/ CASTERS 0 0 49.1 0 STAFFORD SMITH CUSTOM 12" X 72' S.S. WALL SHELF il 0 • 20.1 1 TABCO KLAG-304-X 48" LONG WORK TABLE W/ CASTERS _ 0 •• 50 1 STAFFORD SMITH _ CUSTOM 5" X 12" S.S. WALL SHELF M 0 • 20.2 1 TABU] KLAG-305-X 60' LONG WORK TABLE W/ CASTERS 0 • 51 1 STAFFORD SMITH CUSTOM TOOL KIT K 0 0 20.3 0 TABCO KLAG-306-X 72" LONG WORK TABLE W/ CASTERS 0 • 52 1 STAFFORD SMITH CUSTOM 6' FIBERGLASS LADDER cnm Ci) C A1 . 04 d GENERAL CONTRACTOR & VENDOR COORDINATION ,Stafford-Smith, Inc. -Zoup! Projects Food Service Electrical Plumbing/Fire Mechanical BY OTHERS Contractor Contractor Protection Contractor Contractor Furnish Install Furnish Install Furnish Install Furnish Install Furnish Install General Responsibilities I. IT 15 REQUIRED THAT THE G.G. AWARDED THE CONTRACT WILL, PRIOR TO ANY CONSTRUCTION, PERFORM A COMPLETE AND - - THOROUGH SNAPPING OUT AND SCALING OF ALL WALLS, FIXTURES AND EQUIPMENT, BASED ON PLANS AND THE MANUFACTURERS' General EQUIPMENT GUT SHEETS. AM' DISCREPANCY BETWEEN THE PLANS AND ACTUAL CONDITIONS HILL BE REVIEWED WITH THE ZOUPI deliver, uncrate and set in place equipment X X c___A). IA•77, rA./.1\ - ,:,.. -' , • REPRESENTATIVE IMMEDIATELY, all floor,wall, roof penetrations, sleeving, and fireproofing/insulating/re- X X X X X X X X 2. DELAYS IN CONSTRUCTION DUE TO THE G.C.'S FAILURE TO PLAN FOR APPROPRIATE PRODUCT DELIVERY LEAD TIME WILL NOT BE sealing necessary for the performance of your work. ACCEPTABLE. start-up,testing and calibrating equipment X X 3. A FURNITURE, FIXTURE AND EQUIPMENT (F.F.4 E) SCHEDULE WILL BE PROVIDED TO THE G.G. BY THE ZOUP! REPRESENTATIVE. THE Electrical - -� DELIVERY AND INSTALLATION FOR THE F.F,BE. ITEMS W1LL BE SCHEDULED ACCORDING TO COMPLETION DATES OF MILESTONES all final electrical connections and interconnections to equipment room X X FROM THE CONSTRUCTION SCHEDULE. IT 15 THE RESPONSIBILITY OF THE G.G. TO COMMUNICATE ANY SPECIAL building services SEAL INSTRUCTIONS/CIRCUMSTANCES TO THE VENDOR PRIOR TO DELIVERY. all control wiring X X _ interwiring complete for serving counters X X CONSTRUCTION MATERIAL: electrical disconnects as required X X THE G.G. AND ITS SUBCONTRACTORS ARE SOLELY RESPONSIBLE FOR SUPPLYING ALL CONSTRUCTION MATERIAL AND EQUIPMENT TO Electrical Load Centers and/or Panelboards per bid documents _ X X COMPLETE THE PROJECT BUILD-OUT PER THE PLANS PROVIDED. ALL G.G.- SUPPLIED Interconnections of electrical feeds within foodservice equipment that MATERIAL SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS' SPECIFICATIONS AND LOCAL ORDINANCES AND CODES. X X were disconnected for shipping purposes. ca c Mechanical (1) -2 Ti-P' cv MILLWORK: L ,d) a IT 15 THE G.C.'S RESPONSIBILITY TO INSTALL MILLWORK IN ACCORDANCE WITH THE PLANS AND INSTALLATION INSTRUCTIONS all final plumbing connections and interconnections to equipment from (111) o10 p o . ,- PROVIDED PROVIDED BY THE MILLWORK COMPANY. building services X X e m all plumbing materials including pipes,traps, stops, valves,fittings, shut- •— ffi -8 0 Ti- N ALL MILLWORK - INCLUDING CABINETRY, TABLES, LUNCH COUNTER, BOOTHS, BOOTH PLATFORMS, BOOTH WALLS, CHAIR RAIL AND offs,water hammer arrestors,pressure reducing valves,etc.for a X X - D 0 cv cv MANAGER'S OFFICE DESK AND SHELF - ARE SUPPLIED BY THE ZOUP! VENDOR. complete and operable system }� o E •Fi •` •Es 4- '4 IT IS THE G.C.`5 RESPONSIBILITY TO UNLOAD AND BRING THE ITEMS INTO THE SPACE. MILLWORK MUST ALSO BE INVENTORIED AND hand sinks X X . ., 0 `o o D INSPECTED FOR DAMAGE AT TIME OF UNLOADING AND DELIVERY, ANY MISSING OR DAMAGED ITEMS MUST BE BROUGHT TO THE - - 0 ` 0 J c\i J Q. ti. ATTENTION OF THE DRIVER, FRANCHISE OWNER AND ZOUPI REPRESENTATIVE IMMEDIATELY. FAILURE TO DO 50 WILL VOID ANY sink faucets X X + a) RECOURSE THE FRANCHISE OWNER AND ZOUP! REPRESENTATIVE HAVE TO FILE A CLAIM WITH THE VENDOR AND DELIVERY COMPANY. waste fittings X X 2 0_ S.C. GWILL BE HELD LIABLE FOR REPAIR OR REPLACEMENT OF ANY DAMAGED OR MISSING ITEMS NOT NOTED BY THE DRIVER ON THE flexible gas hoses for mobile equipment X X ° SHIPPING INVOICE. O appliance gas pressure regulators X X m p C KITCHEN EQUIPMENT; primary gas pressure regulator for main feed to equipment X X `m -Ca ZOUP!'S KITCHEN EQUIPMENT VENDOR WILL DELIVER,UNCRATE, BRING INTO THE SPACE AND ASSEMBLE ALL KITCHEN EQUIPMENT ITEMS, floor troughs X X �© c EXCEPT FOR THE ITEMS LISTED BELOW. SUBCONTRACTORS WILL BE PRESENT AT DELIVERY AND SHOULD ASK ANY QUESTIONS AT Hoods L ,-,% C)) o THAT TIME. ALL MECHANICAL, ELECTRICAL, AND PLUMBING CONNECTIONS ARE THE RESPONSIBILITY OF THE G.G. AND ITS exhaust ventilator X X e 1 SUBCONTRACTORS. 1:110 n o o duct work and duct connections at hood collars X Xcp I c0 co fan starters and/or relays X X -- m O cc 0 6i CD control wiring from fan starters to hood fan controls X X .,:.I : 'c CL)ca -c ' ITEM NUMBERS (FROM KITCHEN EQUIPMENT SCHEDULE) TO BE INSTALLED BY THE G.G.: inter-connecting light circuits at field joints X X ,,4 m a m T- r coco ,- CO electrical connections to lights. X _a) cv N cu - 3 8 3.1 - BABY CHANGING STATIONS ■■ 7 Q d �.I -FAUX HOOD AND STAINLESS STEEL WALL PANEL light fixtures(installed in hood at factory) X X - 10 - PAPER TOWEL DISPENSERS _ U coo ti , - 13 4 13.2 - EXHAUST HOOD AND STAINLESS STEEL WALL PANEL air balancing X X - 13.1 - SUPPLIED AND INSTALLED BY G.G. permits to hang hoods(if required) X - 4q, 4q.1, AND 50 - WALL SHELVES closure panels to finished ceiling X X air balancing X X SMALL WARES: Fire Suppression Systems PROJECT: THE ZOUP! VENDOR WILL DELIVER SMALL WARE ITEMS TO THE SITE ON THE SCHEDULED DELIVERY DATE; THE G.C. 15 RESPONSIBLE , FOR UNLOADING ALL ITEMS AND BRINGING THEM INTO THE SPACE. SMALL WARE ITEMS INCLUDE ALL POTS, PANS AND KITCHENWARE. Stafford-Smith, Inc. -Zoup! Projects Food Service Electrical PlumbinglFire Mechanical BY OTHERS THE DINING ROOM CHAIRS AND STOOLS ARE ALSO INCLUDED IN THIS DELIVERY. Contractor Contractor Protection Contractor Contractor a BEVERAGE DISPENSERS: Furnish Install Furnish Install Furnish Install Furnish Install Furnish Install Q BEVERAGE DISPENSERS ARE SUPPLIED AND INSTALLED BY THE ZOUP! BEVERAGE VENDOR. THE G.G. 15 RESPONSIBLE FOR Chemical Only System 0 COMPLETING THE CABINETRY, ELECTRICAL AND PLUMBING REQUIRED FOR THE INSTALLATION OF THE UNITS PRIOR TO THE system components X X p[ INSTALLATION DATE. permit,testing, certification X O Lu chemical piping from hood to ottoman X X O f INTERIOR GRAPHICS: gas shut-off valve(installation) X X - - 1— Q ALL INTERIOR GRAPHICS (PER THE PLANS) ARE SUPPLIED BY THE ZOUP! VENDOR. THE G.G. 15 RESPONSIBLE FOR UNLOADING AND gas shut-off valve(electrical connection) )( X W D rr) BRINGING THE ITEMS INTO THE SPACE. THE G.G. WILL INSTALL ALL WINDOW GRAPHICS, WALL GRAPHICS, SIGNAGE, WALL FRAMES AND PROMO BOARDS PER THE CONSTRUCTION DOCUMENTS AND VENDOR INSTALLATION INSTRUCTIONS. resets for electrical gas valve ill X X ¢ a N N.O./N.C. contactors for fan sequencing and or tire alarm interface M n DATA NETWORKING: (contactors supplied as part of ottoman only) X X \'‘ : z THE ZOUP! NETWORKING VENDOR 15 RESPONSIBLE FOR SUPPLYING AND INSTALLING ALL NETWORK WIRING AND NETWORKING all electrical wiring as required to interconnect ottoman, gas shut-offCNo c O EQUIPMENT. THE G.G. WILL BE RESPONSIBLE FOR MOUNTING THE VENDOR-SUPPLIED MONITOR/P05 BRACKETS TO THE WALL FOR THE valves, resets,building alarms,shunt trip circuits,fan X X OM5 COMPUTER AND RETHERM TRACKER COMPUTER PER THE CONSTRUCTION DOCUMENTS. ALL MILLWORK AND ELECTRICAL WORK controls/sequencing as required. s LJJ z ( O WILL BE COMPLETED PRIOR TO SCHEDULED VENDOR INSTALL DATE. Shunt trip breakers X X : W 0 Z Water and Chemical System (additional work required) ''--I in POS AND DIGITAL MENU BOARDS: ------- _-.- -__-- f~ ---- THE ZOUPI POS VENDOR 15 RESPONSIBLE FOR SUPPLYING AND INSTALLING ALL POS EQUIPMENT. THE G.G. WILL BE RESPONSIBLE FOR potable water or sprinkler water feed to ottoman X X [!') L9 v) Q MOUNTING AND INSTALLING THE VENDOR-SUPPLIED LCD MENU BOARDS AND WALL BRACKETS ON THE SERVING AREA WALL PER THE water piping from ottoman to hoods(s) X X ZQ CONSTRUCTION DOCUMENTS. ALL MILLWORK AND ELECTRICAL WORK WILL BE COMPLETED PRIOR TO SCHEDULED VENDOR INSTALL water pressure reducing valves X X I ii= DATE. permit,testing, certification X X EXTERIOR BUILDING SIGNAGE: lockable water shut-off valve for water feed to ottoman X X THE ZOUPI SIGN VENDOR 15 RESPONSIBLE FOR THE PERMITTING, FABRICATION AND INSTALLATION OF ALL EXTERIOR BUILDING Walk-in Panel coolerslF.reezers SIGNAGE AND AWNINGS. THE S.C. 15 RESPONSIBLE FOR SUPPLYING AND INSTALLING ALL PHOTOCELLS, TIMERS AND ELECTRICAL wall, ceiling,and floor panel assemblies X 1 X _ - CD X CONNECTIONS PER THE CONSTRUCTION PLANS. installation permit if required - -- - -L - i--f CO2: prefabricated floor panels when specified X X CD THE ZOUPI VENDOR WILL DELIVER AND INSTALL THE GO2 SYSTEM AND EQUIPMENT ITEMS ON THE SCHEDULED DELIVERY DATE. light fixtures X X `—i light bulbs X X _ all electrical wiring and interwiring to door assembly and light fixtures X X CHEMICAL DISPENSING: - THE ZOUPI VENDOR WILL INSTALL ALL CHEMICAL DISPENSING EQUIPMENT FOR THE THREE-COMPARTMENT SINK AND MOP SINK AREAS. all wiring to heated pressure relief vents X X THE G.G. 15 RESPONSIBLE FOR HAVING ALL FINAL PLUMBING COMPLETED PRIOR TO THE INSTALLATION DATE. LOCAL CODE MIGHT all penetrations through wall panels and ceiling panels for required X X REQUIRE ADDITIONAL SIPHON OR BACK FLOW PREVENTION DEVICES; THIS WILL BE THE RESPONSIBILITY OF THE G.C.'S PLUMBING electrical conduit by FEC. Sealing of opennings by EC SUBCONTRACTOR. ceiling closure panels and wall trim X X MARK: ISSUE: DATE: wiring to remote monitoring stations for temperature alarms X X Review 50% 01/18/16 Remote Refrigeration Review 90% 02/05/16 evaporator coils and condensing units X X Property Owner Review 02/23/16 refrigeration piping from evaporators to condensing unit(s) X X Permit Set 03/11/16 permits X wiring from time clock to freezer evaporators X X _ evaporator drains,heat tape, insulation from coils to floor drain/sink X _ X final electrical connection for freezer drain heat tape X interwire and final electrical connections to coils,condensing units, X X refrigeration racks, etc. electrical disconnects(if required) X X Garbage Disposers Stafford-Smith, Inc. -Zoup! Projects Food Service Electrical Plumbing/Fire Mechanical BY OTHERS Contractor Contractor Protection Contractor Contractor • Furnish Install Furnish Install Furnish Install Furnish Install Furnish Install garbage disposers X X interwire remote startlstop switch to disposer X X electrical disconnect(if required) X X PROJECT#: 15085.01 waste connections at disposer X X DRAWN BY: DKN CHECKED BY; DJB Soda.Systems soda line conduit from soda system to dispensers X X Arkinetics,Inc.and their Consultants shall be deemed the authors and owners of their respective Instruments of Service and shall soda lines X X retain all common law,statutory and other reserved rights,including CO2 lines X X copyrights.The Instruments of Service shall not be used for future N additions or alterations to this Project or for other projects,without 0 potable water connections at carbonator X X the prior written agreement of Arkinetics,Inc.Any unauthorized use C y of the Instruments of Service shall be at the Owner's sole risk and ]electrical connections to carbonators&dispensers X X l without liability to Arkinetics,Inc.and their Consultants 70 N ice Mines ar lneUcs C 2016 CW ice machine&bin X X water filter X X DRAWING TITLE: D interpipe water through water filter x x RESPONSIBILTY MATRIX ;p electrical disconnects X X 0 0 rRemirte'Filter Systems 7JFilter Head and Catridges X X 13 Water Supply to Filter System X X rn73 Interpiping from Filter system to individual points of use. X X K Final Utility connection to equipment connected to filter system X X = 'Miscellaneous . (I) m __n - Shelving,pR Racks, etc. X X X SHEET#: ( Concrete and Tile floor X X r 0) Al • O5 0 (o 'rt 0 0 0 l I I GENERAL NOTES; , I r ■ I / . I. ALL SOFFITS TO BE PAINTED P-2b (DUNMORE CREME). ALLOW ACCESS TO SIGN 26 CONTROLS FROM ABOVE / r I I 2. CONTRACTOR TO REATTACH (STAPLE) LOOSE INSULATION AT GYP CEILING, LEAVE TOP VERIFY LENGTH, WIDTH, 4 DEPTH OF SOFFIT W/ SIGN COMPANY ROOF DECK. SEAL PORTION OF SOFFIT FOR SIGN CONNECTIONS 41-6" 8'-6" 5'-2" 1'-II' OPEN, WORD. WITH SIGN 44 5, " 5',-4/41 Al I / I-I4" y //I CONTRACTOR y q 1E44. / rI r 2- ■ — n --1,— —1 / \ KEYED NOTES: ■ N n Nm . NEW GLA55 PENDANT CANOPY MOUNTED AT GYP. cn o 15 Ar I I s. I 1� - o o r d. BOARD CEILING OR TRACK AT ACT CEILING o_ p O T O in wow-�� � . :. GYP�D..- 0— RP 1 � LOCATIONS - CENTER OVER TABLES. C a) Tr co 'n • /GYP BD ,, 2 U 6 6 10' 0, I .:: .I1- i 0 N N AREA I I <RP-2> NEW GLASS OR FABRIC PENDANT (SEE LEGEND O N o ABOVE)- CENTER FIXTURES OVERa) C C ��•.MJ��..�-:..�-���•��.�����-- �•:•�� ��� �. -��� BOOTH TABLES 100 n �:�:;-. ,• � �� ��. � : .'GYP:$D �'f \ RP 10 0 � .o E c� r c� c � 0 0 0 0 —' 1x . . :: '-o r o 0 o Q • 0 I 15-11%" 5'-�4" I �• .•'' "•'':-'• :•''• .••' = J <RP-3> NEW 4-O BLACK TRACK - CENTER ON ZOUPI LOGO. U J N J - LL SCC-25/2�� VERIFY IN FIELD + ai U7 zQ � .. ,..,,,0,_01..„ 111fON[EN : : ::-=�����:. :;.:: . . V y. GYP B •.:( 10.6:j.....: :-- :v: .: : : :- C 0— V� �V� 9-6 •• • •- • - (RP-4> NEW 12'-O" TRACK - MOUNTED AT BACK OF BULKHEAD Qy A2.01 O f 0�- - - r.� I 0 HALLWAY 0 `r .. I ' (CENTERED OVER SOUP COUNTER). ■ 0 o C z 102 ) ..-I I qI5 o - Iu , (/RP 5`) NEV 8'-O" TRACK - MOUNTED AT BACK OF BULKHEAD ` I \ / co (CENTEREDI OVER FOS STATION). L. o _ RP-2 I : I a' 2 0 k O / I:- 10'-6D A2.01 0 - O l- NEW 5'-O" TRACK - MOUNTED AT BACK OF BULKHEAD M i § a� -2 ! o 0 2-p 81-0" READER <RP-6> to a o ■ v LL yI I RP 7 l <RP 9 (CENTERED OVER "HAND OVER" COUNTER). a ,.2a.).-2 ! T 9 ° O r ® @ -{RP-3> 0 0 / > <RP-7> LINE OF NEW EQUIPMENT HOOD BELOW. . D 1:3 713 75 ,i. ,,,_ ap c� m � v GYPBDk � a cflco E I GYP BD0 A2.01 0 I I l <RP 8� NEW EQUIPMENT EXHAUST. N N N 8.-6" RP 5 - RP 4 <RP 9� LINE OF NEW FREEZER ■ `o — «� q QUEUINi. , r , � p 101 O 0 ¢ Uc� U SIL Di 10 0 -,- RP-8 I �RP 10� NEW LED LIGHT FIXTURE OCCURS WITHIN FREEZER I 3 6 e_l■� .: - - - - - = BELOW. PROVIDED BY FREEZER MANUFACTURER AND r RP-1 1 r 'r Ile `r "`�. ' ` r r l� r r r r r INSTALLED BY G.G. • 2 ;) I W-O" RP-6 �. _ a �� GYP 8D , Be'`�. O e O e _i_____ r 4 I \ PROJECT. i 1 �, C A2.a1 . , . i `� 0 SERVING GDC-22/2 GYP BD \ KITCHEN REFLECTED CEILING PLAN LEGEND ( 103 ) 8' 0^ �./ \ O ( 105 ) Q I I INDICATES FINISHED CEILING MATERIAL. SEE CC .: ;a: .::_.:::-: : Es O O O O I 1/ 0,43" O O RP-8 l i=- ACT-2 FINISH SCHEDULE FOR INFORMATION. O Wm ■�} in I in le — — 11Y-0" 0 oC INDICATES FINISHED CEILING HEIGHT I— Q CB) ■ \ tV : MANAGERS ` W nn STATION ,-- y c oC `J (NI \ I I _ I r - ` - - - - - I '-- Lf) N lI II — x - - - - - - - - �- - - — - - - - - NEW 2x4 LAY-IN LIGHT FIXTURE WITH PRISMATIC Cr)M I q 144. 2'-0" 2'-O" 14,ej ���/2" 3'-O" — — — — 33'-II" O Z cm LENS. te \ N CYO to / 36" X 36" SOFFIT G 8` / f # V) 1- 74 I A.F.F. ABOVE OVEN. " z U �. / � NEW SURFACE MOUNTED TRACK LIGHT FIXTURE, AIM s, � � i r WALL TILE TO EXTEND I • DOWN AT COUNTER W 1'5-5 REFLECTED GEEING PLAN &IL-1k `�"'� z o / TO UNDERSIDE OF A2.01 I--I CC �� ■ SOFFIT. I SCALE: 1/4" = 1'-0" ~ 2 / --'" NEH RECESSED CAN DOWNLIGHT (SEE 0 (A Q / / APPROXIMATE LOCATION O ELECTRICAL DWGS FOR ADDITIONAL INFORMATION) N.4„ Z < I OF NEW RTU (SHOWN = 1-- 1R- — — — — NEW RECESSED "CAN" DOHNLIGHT (SEE ELECTRICAL (,/) DASHED), SEE O MECHANICAL DRAWINGS. DW65 FOR ADDITIONAL INFORMATION). < O NEW FREEZER LIGHT BY FREEZER MANUFACTURER r-I O SERVINGQUEING LEAVE EXPOSED FOR SIGN CONNECTIONS NEH HALL MOUNTED LIGHT FIXTURE 1 -ABOVE DROP CEILING 4 A l 3/" MTL STUD KICKER /I/ BRACE PLACED ON 1ALTERNATING SIDES OF PENDANT LIGHT FIXTURE (BOTTOM OF FIXTURE TO MARK: ISSUE; DATE: HALL AT 48" OC, MIN 2 BE 6'-O" AFF). SEE SHEET A2.02 FOR FOR // PER WALL. EXTEND AND SEE SHEET A2.02 FOR FOR Review 50%d FASTEN SECURELY TO Review 90/0 01/18/1605 SEISMIC CONNECTIONS ,/ SEISMIC CONNECTIONS UNDERSIDE OF Property Owner Review 02/23/16 .` STRUCTURAL DECK, BEAMPermit set 3/11/16 TRACK.NEW SUSPENDED PENDANT LIGHT FIXTURE OR. PERLIN ABOVE (BOTTOM OF FIXTURE TO BE t'-D" AFF). USE - MONOPOINT TRACK HEAD ADAPTER AT SINGLE "_LiT! FIXTURE Zo I:�I I I _ B/NEW FINISH CEILING NEH PENDANT LIGHT FIXTURE WITH FABRIC SHADE GEILI EL. = COORD. N6 PLAN 0 (BOTTOM OF FIXTURE TO BE 6'-0" AFF). NEW SUSPENDED SUSPENDED ACOUSTICAL CEILING ACOUSTICAL CEILING A/ — SEE SHEET A2.04 /2E2t ,- \ \-- SYSTEM `\ NEW 554" METAL STUD KICKERN / COORDINATE EMERGENCY AND EGRESS AT MAX 48" OC. • • EXISTING WALL FT I • " IXTURES WITH ELECTRICAL DRAWINGS - n � n � \ \ PROJECT #: 15055.01 NEW 3%" METAL STUD NEW EXHAUST FAN �--- -- KICKER AT MAX 48" `) 1 Ii, SEE : OG. Q z DRAWN BY: DKN CHECKED BY: DJB .■D B/NEH FINISH CEILING III I ri - / t CHORD, CEILING P Arkinetics,Inc,and their Consultants shall be deemed the authors _B/NEW FINISH CEILING _ and owners of their respective Instruments of Service and shall I � retain all common law,statutory and other reserved rights,including \-- 71 J•► n copyrights.The Instruments of Service shall not be used for future - H./CEILING PLAN NEW 5/8 GYP BD NEW UPENDED FINISH MATERIAL SCHEDULE p additions or alterations to this Project or for other projects,without r r / (PAINTED) ON 3-5/8" the prior written agreement of Arkinetics,Inc.Any unauthorized use N /✓/ METAL STUD FRAMING SYSTEMACOUSTIGAL CEILING �/ Z of the Instruments of Service shall be at the Owner's sole risk and Q NEW SUSPENDED „ p- 0 LOCATION CODE MATERIAL MANUFACTURER PRODUCT NO. I DESCRIPTION/REMARKS without liability to Arkinetics,Inc.and their Consultants C ACOUSTICAL CEILING AT I6 OC MAX EXTEND ; ' arkinetics ID 2016 STUD FRAMING UP TO AC-22 VINYL CEILING, PANEL USG VINYL CLAD SHEETROCK 2 FT X 4 FT N SYSTEM = � STRUCTURE ABOVE AND `, Ce 3 - v Q DRAWING TITLE: BRACE. W u_ iL AC-23 CEILING GRID U50 DX I5/I6IN., GOLOR-WHITE wNEW GOVT CORNER BEAD, 0 z REFLECTED CEILING PLAN 2 ILI CEILING AC-25 ACOUSTICAL CEILING PANEL USG GLACIER 101, COLOR-SANDSTONE 040, 2 FT X 2 FT �' NEW CONT CORNER BEAD, • B/NEW FINI_HCD BULKHEAD — AC 26) GEILIN6 GRID USG DX I5/I61N., COLOR-SANDSTONE 040 p YP. EL = WORD. _ W/GEILIN6 PLAN l ( P-26 )l PAINT - COORDINATE WITH HALL FINISHES • Xl B/NEW FINISH BULKHEAD : :.,..: ...,..� J EL = 8'-6" AFF NEW 5/8" GYP BD ii P 30 PAINT - HVAC 6RILLES/DIFFUSERS N ALL AG25/26 AREAS Li rn (PAINTED) ON 3-5/8" > xi t 478," I METAL STUD FRAMING SEE RCP AT I b" OC MAX. - - ---- - -- i SHEET t+: - BULKHEAD SECTION SECTION COSOFFIT SECTION °BULKHEADA2 • 0 1'3 A 1-1/2" = 1'-0" SERVING TO QUEUING 1-1/2" = 1'-0" SEATING 1-1/2" = 1'-0" SEATING AREA _. a) O 04" F.T. 2X12,SCREW TO BOTTOM OF BEAM Air METAL TRACK,SECURE TO 2X/5 HITH SIMPSON TRUSS HEAD SCREW #8 11/4", • Kit TOTAL 3 PER CONNECTION • _2x12 • r($ . • SECURE KICKER TO \ __; EXISTING HOOD BEAM EXISTING KI HOOD BEAM W/SIMPSON OR EQ TRACK TO 2X6 w 110, IN/SIMPSON OR EG HEAD SCREW *8 11/4", C, _, HEAD SCREW *8 1 1/4", C1-% TOTAL b PER zC ' w TOTAL b PER CONNECTION F p CONNECTION 0 I s FOR ATTACHING KICKERS TO z 0 HOOD FRAMING SIMPSON V SEAL TRUST HEAD SCREW *8 4 I/4', l TOTAL b PER KICKER ow i dip 0 0 . . CY 0 0 0 0 0 \ 0 0 _j I I . 0 0 0 0 \ � I ...b( I � WI s= CONTINUOUS METAL EXISTING WOOD0 �f� 2 in O N- BEAM W/METAL 2Xb FIRE TREATED WOOD 4'0.G. SECURE CONTINUOUS METAL TRACK, Ca a� +. O p .– TRACK, TRACK,SCREW TOTO BOTTOM OF TRUSS SCREW TO BOTTOM OF 0ace I- l) T- 0 2X6 WHICH IN TURN 15 STUDS FASTENING EXISTING WOOD BEAM LOCATIONS TRUSS . _ c0i V 2 ca ctj SCREWED TO THE BOTTOM OF TRUSS, 2X6 FIRE TREATED WOOD, BLOCKING Q C‘I CV c CV SECURE RUNNER TO C C O O 3" DECK t BETWEEN TRUSS AT METAL KICKER J� O 2Xb W/SIMPSON OR LOCATIONS - SEE DETAIL o E co (T; 4 EQ TRUSS HEAD SCREWS 12" O.G. 0 •� SCREW Na. I I/4", _ 11 O O 0 O TOTAL 3 PER T > N J N A 12 L� •� m 52 C EXISTING WOOD 4 j BEAM E''rcii c. l a) 1 1 O 0 (% i .237,3, 1 ,:,§ c.ci ._ r-- — CONTINUOUS 2X6 FIRE 25 GA. 35/8" MIL STUD KICKER BRACE TREATED WO00 AT _- PLACED ON ALTERNATING SIDES OF HALL AT BOTTOM OF TRUSS AT q:> c O c N- N ,' 48" OC, MIN.2 PER HALL. EXTEND AND WEB INTERSECTION ca 6 ct� c>3 /0 FASTEN SECURELY TO UNDERSIDE OF Ti) c7 > CV N ° STRUCTURAL PECK, BEAM OR PERLIN ABOVE, . N ti / a) � ° KICKER TO TRUSS 25 GA. 3%8" MTL STUD KICKER BRACE PLACED ON Q U C7 V IQ- L: ALTERNATING SIDES OF HALL AT 48" OC, MIN 2 PER N // HALL. EXTEND AND FASTEN SECURELY TO UNDERSIDE OF - ° STRUCTURAL ABOVE. i \\ SECURE KICKERS TO STUDS WITH 3/8" NIO SHEET 3 5/8" METAL STUD KICKERS AT ° \ METAL SCREWS, MIN, 4 PER CONNECTION 4'-0" O.G. MAX, SECURE TO EXISTING ° ° ° HOOD BEAM WITH SIMPSON TRUSS ' ; ° i HEAD SCREW*8 11/4", TOTAL b PER °� , PROJECT: CONNECTION 1111111!III11111111111III EII III III III III . NEW SUSPENDED ACOUSTICAL CEILING SYSTEM SEE A204 0 E Q _ 1 III0 25 GA. 35/8" METAL STUD KICKER AT MAX \ 48" OC., ALTERNATE KICKERS °` . II ° O LSI \V ` °/o� O n/ �>, NEN SUSPENDED ACOUSTICAL CEILING _ 25 GA. 35/&' METAL STUD KICKER AT MAX 48" OG. I— I< �• • SYSTEM SEE A2.04 SECURE KICKERS TO STUDS WITH 3/8" 010 SHEET• Lu m ` METAL SCREWS, MIN. 4 PER CONNECTION NEW 5/8" GYP. BOARD (PAINTED) ON 3 5/8" METAL 1 1 1 11 1 11 3 111 111 1 f I l I l 1 I I i l l I l I l l l I l I l l l l l l l • ` c N STUD FRAMING AT Ib" OC MAX EXTEND STUD FRAMING M I b NEW 5/8" GYP BD (PAINTED) ON 3-5/8" METAL STUD ,. UP TO STRUCTURE ABOVE AND BRACE. \�, r-I z al :a FRAMING AT 16" OC MAX EXTEND STUD FRAMING UP TO NEW SUSPENDED STRUCTURE ABOVE AND BRACE. `° N o' O OC NEW SUSPENDED ACOUSTICAL GHLING ACOUSTICAL CEILING SYSTEM - BEE SHEET A2,04 4, emaiN \ii., • SYSTEM SEE SHEET A2.04 L�.l�/.! Z o Ce O O z CI 1--1 is) = � = Q °` o Z < L_9 Q a 4 4 > 1--1 i V) s 171 LT, _2'4 1/2' 1 O NEW 5/8' GYP BD(PAINTED) ON 3-5/8" rri METAL STUD FRAMING AT 16"OC MAX. O t--1 GYPSUM BOARD CEILINGS SHALL BE FASTEN TO FRAMING MEMBERS WITH SCREWS SPACED NOT MORE THAN 12 INCHES ON CENTER ALONG THE FRAMING MEMBERS. SCREWS SHALL BE IN ACCORDANCE HITH ASTM 0454 I __ _1 A MARK: ISSUE: DATE: Review 50% 01/18/16 Review 90% 02/05/16 A SEISMIC BRACING SECTION B SEISMIC BRACING SECTION Property Owner Review 02/23/16 Permit Set 03/11/16 1" = 1'-0" 1" = 1'-0" O k PROJECT#: 15085.01 DRAWN BY: DKN CHECKED BY: DJB Arkinetics,Inc.and their Consultants shall be deemed the authors and owners of their respective Instruments of Service and shall retain ali common law,statutory and other reserved rights,including copyrights.The Instruments of Service shall not be used for future N additions or alterations to this Project or for other projects,without Othe prior written agreement of Arkinetics,Inc.Any unauthorized use of the instruments of Service shall be at the Owner's sole risk and C without liability to Arkinetics,Inc.and their Consultants 13 N arkinetics 0 2016 3 W DRAWING TITLE: 5 CEILING PLAN DETAILS > 70 0 0 \ \ \ \ m 73 K co rn re r 1 0 2 0) A2 . 02 .....,1 m ,A). c 1.-(:.:1.131"..,4„, tsI2GA VERTICAL HANGER / C1--)'s TYPICAL 457 HIRE AT 4'-0" 45° SPLAY HIRE BRACING IN CEILING CLIP OR I6GA STRAP PLANE OF MAIN RUNNER ALL HIRES ATTACHED TO MAIN RUNNER 4 (2) 1.2 GA. STEEL SHEET METAL SCREW DIRECTIONS LOCATED AT I2" OC HIRE HITH MIN. POSITIVE CONNECTION EACH WAY, TYPICAL AND NOT TO 3 TURNS IN li" TO FIXTURE EXCEED 6-0" FROM WALLS SEAL (SLACK WIRE) \ ,. 45° 1 1 / 1:„ ( 45° DUTY, RATED FOR CATEGORY DETAIL 2'x4' LAY-IN .\\\ / Ar LIGHT FIXTURE ` u2, . 0 'N 22 o n og o ti) 5)- � o LATERAL SUPPORT WIRES � ,,�� � a) s � � u? MIN AT.2 FIXTURES WHERE _ /; ro 0 = i co cfl ATTACHED 4 ° 'N.111, -1.- .IlA 5 MIN 3 TURNS IN II" 0 N 0 N N TYPICAL 45° \� " la) le Ell. - SPLICE o T c` D AGONAL SUPPORT 444 a 1 O J N . d ii 1'x4' LAY-IN ■= 7"---WIRE CR055 RUNNER T a$i U LIGHT FIXTURE / _ WHERE 2 - XTURES MAX. MMIN g In s 412"1 % PLAN ABUTT PROVIDE o bGA STRAPS 4 ► Se .W 2 DIAGONAL SUPPORT MAIN RUNNER mi% o ", HIRE L z § 0) a a iel El Q C ( )FOR LAY-IN LIGHT FIXTURES 0SUSPENED CEILING SYSTEM � 2 8 M o � o coT _ 7 N.T.S. SEISMIC RESTRAINT DETAIL N.T.S. SEISMIC RESTRAINT DETAIL ` ' • ` .s. Q) if) - - ■� o Q � N NN UciU Vii: 8., / / MAX I b NORMAL VERTICAL L2GA PROJECT: HANGER WIRES • MAX ` VAX 0 Q ALTERNATE L2GA HANGER SEE PLAN FOR_2 SIDES HITH 'FREE' ENDS. ALL CEILING TEES SHALL BE HEAVY DUTY, RATED FOR 0 HALL PARTITION HIRE MAX 10° ANGLE NO CONNECTION TO WALL TEE. CATEGORY 'D' SEISMIC DESIGN. f 6 ATTACHMENT TO HALL OR DIRECT HIRE TO STRUCTURE O LU SEE PLAN FOR 2 SIDES MIN 3 TURNS IN li" © WITH 'FIXED' ENDS. O < POSITIVE CONNECTION TO W m WALL TEE. MIN y" MAIN NG EE SYSTEM ANGLE ON ALL SIDES. p m Q fV I - f ;484 \Ttt '�% Z dl 0 \ lot" MA, 4 n � O �� Z HALL CLOSURE �— SPACER OR / \, •' ALL FIXED END TEES PROVIDED W ANGLE / �' COMPONENT RTO RESTRICT 2' ` i 0 Z 0 SPREADING OF PERIMETER a i o d ` HITH POSITIVE �� CONNECTION TO HALL ANGLE. 0 ~ OPTIONAL: •4 ��= 1 I— I ANGLE HALL ARMSTRONG BEAM END "UNATTACHED" •, I �!\J C� Q RETAINING CLIPS AT •a 2 / •,v Z Q SUB-EE CONNECT TO MAIN PROVIDE ALL TEES HITH a. '–' 5' END GAP AT FREE ENDS. ,,4 = "ATTACHED" `0 •,at Q TILE LAY-IN CEILING CEILING SUSPENSION DETAILS o TACOUSTICAL N.T.S. SEISMIC RESTRAINT DETAIL N.T.S. SEISMIC RESTRAINT DETAIL 1-1O 1-1 12 GA. SLACK SAFETY HANGERS ATTACHED AT OPPOSING CORNERS ATTACH TO BOTTOM CHORD OF MECH'LJLIGHT FIXTURE MARK: ISSUE: DATE: TRUSS W/ (I) 1/4" x 3" EYE SCREWS, I" PER PLAN. FIXTURE Review 50% 01/18/16 MIN_ EMBED_ INSTALLATION TO Review 90% 02/05/16 COMPLY llE ETAL STUD CZ' Property Owner Review 02/23/16 POSITIVE / Permit Set 03/11/16 C636-"36-ATTACHMENT AT GRID AND STRUCTURE ABOVE. 45° SPLAY WIRE BRACING IN CEILING GRID FOR PLANE OF MAIN RUNNER ALL HIRES ATTACHED TO MAIN RUNNER 4 T-BAR CEILING DIRECTIONS LOCATED AT l2 OC RECESSED FIXTURE EACH WAY, TYPICAL AND NOT TO \ \ / EXCEED b'-O" FROM HALLS s 45° 45° ALL GRID SHALL BE HEAVY `, D' SEISMIC DESIGN. \ „ .. 1;' PROJECT#; 15485.01 4 ° ,5• MIN 3 TURNS IN Ii" ,,1,-- DRAWN BY: DKN CHECKED BY: DJB 411111 SPLICE Arkinetics,Inc.and their Consultants shall be deemed the authors and owners of their respective Instruments of Service and shall GR055 RUNNER retain ail common law,statutory and other reserved rights,including CEILING copyrights.The Instruments of Service shall not be used for future O additions or alterations to ibis Project or for other projects,without TILE �" the prior written agreement of Arkinetics,Inc.Any unauthorized use C POSITIVELY ATTACH MAX, of the Instruments of Service shall be at the Owners sole risk and -0 FIXTURE TO CEILING ie ► without liability to Arkinetics,Inc.and their Consultants N arkinetics C 2016 w MAIN RUNNER DRAWING TITLE: 5 FOR LIGHTING FIXTURES MORE TI-IAN 20 POUNDS SUSPENDED CEILING o SEISMI RA ING FOR RE ESSED LIGHT FIXT RE ®CEILING SUSPENSION DETAILS DETAILS 0 SCALE: NONE N.T.S. SEISMIC RESTRAINT DETAIL 1 rn xi K N m SHEET 4iE:Cr") am A2 . 03 N ii NOTE SOFFIT SEE SHEET A2.01 FASTEN CHAIR RAIL TO 1E-20 ® 1E-18 1E-20 WALL STUDS. PROVIDE / IE-11 <1E-0— 1E-29 ® ® ® KEYED NOTES: WOOD BLOCKING AS I — �• REQUIRED if 1 ® DINING FURNISHINGS BY MILLWORK SUPPLIER, TOP OF CHAIR RAIL I - TYP. (REFER TO MILLWORKSHOP DRAWlGS d am EL. =�'-10" AFF, 111 J Sar+ethiMj F. •ryo>,e N�\� \���� N�\\� N��� \����` ����� INSTALL INSTRUCTIONS). • 1t Always-Ro atihy Sovpf Each Day • Y4 • Carryovt'I a ap • zovp.cor^ • E.,joy! • I :p -�- I ® DINING BOOTHS BY MILLWORK SUPPLIER, TYP. c._. Ixb SOLID CHERRY r.•- dl IMI rWALL HALL IE 29 IE-16 OPO IE 29 (REFER TO MILLWORKSHOP DRAWIGS d HARDWOOD TRIM '•' F/AL A PLAa. PLAQ. �I INSTALL INSTRUCTIONS). PROVIDED BY \ Iex36 _ w 4 MILLWORK SUPPLIER r 0x18 ® \ IE-3 WALL BLOCKING BY GEN CONTRACTOR. ' / (REFER TO MILLWORKSHOP DRAWIGS d AND INSTALLED BY GG. \ WALL IE 12 1E-6 ISI CHAMFERED , 1 T-2 1 +�Aa. - ® or: IE-26 \\\\\ // - \ INSTALL INSTRUCTIONS). SEAL CORNERS AT TOP �� ® "'""T.i . .AND BOTTOM0 I ' r I is 1 I ' �^ " <IE 4� CASEWORK PROVIDED BY MILLWORK ll MEI y II—: f-1 q t— Li f rt - fO�� 1, ��� -� �- \\ / u :vSUPPLIER AND INSTALLED BY GG - TYP. CONT. WOOD BLOCKING • ;p • a A . - a 4 , p_ 4 , ik r F = 1 �, r a - Li'--- . (REFER TO MILLWORKSHOP DRAIN165 4 NOTE: REMOVE AND REPAIR i 0 r 1116 II`, ' ' I II i:ii IIII IIII Itn III Ipl lip Iil \ / 4111 IIIc ICI Hu Ilil nil I I m lu WI Ilii I uu II11 Iii ill ut1 lil \ INSTALL INSTRUCTIONS). OHAI 1111 Ilu ICI Hu 1111 nil I1 EXISTING GYP BD A5 111 I I III lull Hu I Hu ill III Ill 1111 IH \ /------�r:a• IC uil iNI 11 1111 Iul I I '! / lir Itll uIl Ikl In Ill IDIDlyl Il IMI 1111Il 41 111I Irl 1111I i ® COUNTERTOPS PROVIDED BY MILLWORK REQUIRED. A 111 II 7 \ Ir a..-' .-4.11. 1 rV „ r-- 8r- - .rr�r ,,r--trr .r� — � .r 1E-20 SUPPLIER AND INSTALLED BY GC - WORD c _ ® ALL SUPPORT REQ'MTS IN/ MILLWORK y °� m mi on GT SUPPLIER. (REFER TO MILLWORKSHOP 0e° O in o 0 0 1E-4 \ A5.01 (Th NT E RIO R ELEVATION ®INTERIOR ELEVATION DRAWIGS 4 INSTALL INSTRUCTIONS). g % a) _c d- co CHAIR RAIL DETAIL \ _ _ _ = N C.)3" = 1' 0" A l 4" = 1'-0" SEATING AREA SEATING AREA <1E-6> • WELDED FLANGE W/ EPDXY BOLTED POST Egg D O . cv �� / 1/4' = 1' 0 a) , ON o0 INSTALLATION - WORD SIZE AND LOCATIONS c •c ;.c Fa �. � WITH MILLWORK SUPPLIER (TYP). (REFER TO 2 `� 0 n SOFFIT SEE SHEET A2.01 SOFFIT SEE SHEET A2.01T • MILLWORKSHOP DRAWIGS I INSTALL T1 OU J N J r.. tL L INSTRUCTIONS). + co)) U r m If-29 IE-29 IE 29 1E-20 <1E-7> DESK TOP PROVIDED BY MILLWORK CO - .— `rl PLASTIC LAMINATE (WA-463-60 SAFFRON r� 2 • 0 O TIGRIS') W/ BLACK EDGE. INSTALLED BY 6C. ' • Ifs' Not Jvit 04, It'I Zo •! • Low-Fat, Ve •tariat,, Dairy-free, Spicy, Glvter.-free s EQ EQ • Only the freshest • ® IE-22 (REFER TO MILLWORKSHOP DRAWIGS 4 = c oo _ iL3 r / / / :a 1 INSTALL INSTRUCTIONS). rn IE-29 \��� \\�� • Award-wi„„ihy Sovp, Salad aid Sardwlchel IE 30 0 .s -. o ?ovp For Yovr roup - /fc::I3 = <IE-80 cv 00 IE-29 r ! SHELVES PROVIDED BY MILLWORK COMPANY, c � � . x NL TA (ALMOND) W/ HD STANDARDS. `� co ct) N-- r . e ` ,...�1-. 5 LLED B GG. a� O o of of PNIt-09OFrff ____......,..,1-..-. w w, A •� STA NT 13 ftj \ —_A� / NETWORK RACK SUPPLIED AND INSTALLED BY as co co CO ��. \ \ \ / �IE 9� NETWORK VENDOR. GG TO PROVIDE — IE 12 HALLWAY ® ® ]E 12OD 1E-6 1E-14 l - 102 ® - - / lea BLOCKING. N N O L � � � .- r IE 14 / iii ¢ Uc; U a: LI: O �t� \\ .. BEYOND to IE-29 IE 14 / IE 14 O O �� KITCHEN EQUIPMENT (TYP) SEE EQUIP PLAN. - .� IE 10 T -, souw•u u r _ j- r r� / Iil � \ . ! i 1 -� / -- 0 a '° \ IE 11 48” LONG PICTURE LEDGES PROVIDED BY - - MILLWORK SUPPLIER, INSTALLED BY GG. f O \ /_ IE 4 \\ 30"X30" FRAMED PICTURE BY GRAPHICS — 11P11 I PROJECT: ..---P._•.1.1- —�-tom��—�— �r 3 ru 1-11—. . T -'—'s - r� IE 12 SUPPLIER AND INSTALLED BY GG. - TYP. 1E-21 ® �� ® IE 14CEO CEO CIED IX SOLID CHERRY TRIM PROVIDED BY . B 2 g 2 ® <1E-13) MILLWORK CO AND INSTALLED BY GC.( Q T.TER INTERIOR ELEVATIONINTERIOR ELEVATION IE-14 Ixb SOLID CHERRY CHAIR RAIL. SEE DETAIL �IOR ELEVATIINTRIOR ELEVATICON A5.01. = 1' 0” SEATIN0 G AREA D 1/4" = 1'-0" SEATING AREA r IE 15 FRAMED PHILOSOPHY STATEMENT, INSTALLED 0 LC BY GG. I— Q W D m <IE-16> EXISTING ALUM/ GLASS STOREFRONT TO CC V (N REMAIN. Q (V IE-28> m E` <IE 17) OCCUPANCY LOAD SIGNAGE `7 13N z �// CA129vNArOR ® Qui4 0 I..1- 44 r---7 IE-18 ZOUPI LOGO PROVIDED BY GRAPHICS n Z O Ib _''' 13 O 16 48 I i SUPPLIER AND CLEAT MOUNTED BY GG TO BE N _al = O I IE-9 1 IE-8 CENTER BETWEEN ADJACENT DOTS. z Q Ib {O _ A • O Iy 1E-36 r IE 34 t ' 3S ®® ❑ 1-- 1 -- • r "� © ® g I6? r IE-19 DIGITAL MENU BOARDS PROVIDED BY ZOUPI - 1� ~ _ Ce 3 \ l === ___ I ` GG TO PROVIDE WOOD BLOCKING AND (/� Q b c - - , I IE-8 I _ _ � \\ • II • I L I - I INSTALL UNITS - WORD W/ ELECT DINGS - z Q \ O O -- �� i ---1=i ©® TYP OF (3). I Iia _ 93 L IE 14 \ IE 14 , ° ° O LO a E/'} - ON / / t- T •� a „.:.:., �IE 7� 'F ~ 4���---, IE 20 INSTRUCTIONALRAPH SUPPLIER AND BULKHEAD MOUNTED r ^ // ® �_ �I �..__ 13 z IiI I I CO / O ) 0. �- BY GG, TYP. xIE-6 O / :((:T: C P RIfIr-l'i 4 I IE 21 ZDUP! VINYL DECALS AND SIGNAGE PROVIDED ty ~ I{ (6 �'"V" `� BY GRAPHICS SUPPLIER AND INSTALLED BY 0 tlt� r� I , � , . - - B-2 2 IE 2 IE 2 ® CID IE 2 GG - COORD LOCATIONS W/ ZOUPI 1-1GM QUI �I <IE_2 > VINYL GRAPHICS PROVIDED BY GRAPHICS SUPPLIER AND INSTALLED BY GC. INTERIOR ELEVATION INTERIOR ELEVATION NEW VINYL WALL GRAPHIC BY GRAPHICS G) NTE RIO R ELEVATION NTE RIO R ELEVATION INTERIOR ELEVATION 0 L ® SUPPLIER AND INSTALLED BY GG. 1/4" = 1'-0" HALL 1/4" = 1'-0" HALL 1/4" = 1'_0" KITCHEN 1/4" = 1' 0" KITCHEN T 1/4" = 1' 0" KITCHEN IE-24 4-I/2" VINYL LETTERS BY PARAGON DISPLAY MARK: ISSUE. DATE: GROUP HUNG BY CONTRACTOR. Review 50% 01/18/16 Review 90% 02/05/16 IE-25 COKE MACHINE TRANSLITE PROVIDED BY Property Owner Review 02/23/16 GRAPHICS SUPPLIER AND INSTALLED BY GG. Permit Set 03/11/16 \ �IE-22 "O• SOFFIT, WORD IE-26 OPEN SIGN BY OWNER TO BE INSTALLED BY J. 3 GG - CHAIN MOUNTED FROM UNDERSIDE OF `I WITH RCP WINDOW FRAME, PLUGGED INTO SWITCHED I GENERAL NOTES: OUTLET AT STORE FRONT. • Some hihy For Evevyohe • ® 0 IE-27 FLOOR SINKS - WORD W/ PLUMBING DINGS, SCHLUTER OR EQUAL ALONG TOP TYP. EDGE OF TILE 13 �y FINISH MATERIAL REFERENCE. a ` 13-** WORD WITH ROOM FINISH SCHULTER ® lE ZS PLUMBING CONTRACTOR TO INSTALL WATER 1 I 1 I T 1 I I i 1 1 IE 3fi SCHEDULE. FILTER SYSTEM, SUPPLIED BY EQUIPMENT N if - GTI # 50156 GTl # 50155 FIELD TILE VENDOR.FIELD TILE - - ' ' ' EQUIPMENT REFERENCE. WORD is - II • O WITH EQUIPMENT PLAN AND 1E-29 PENDANT LIGHT, TYP - GOORD WITH - CI I I 1 1 1 CTI I* ;i) SCHEDULE. ELECTRICAL DINGS. 50156 FIELD TILE w 1 ; 0 TOILET ACCESSORIES. IE_30 NEW DOUBLE-ACTING DOOR. WORD WITH PROJECT#: 15055.01 Zi) @ ® O I I DOOR/FRAME SCHEDULE. GTI # 5015'I '' — DRAWN BY: DKN CHECKED BY: DIB COVE BASE CTI # 50151COVE BASE O • in I. INTERIOR GRAPHICS AND SIGNAGE J � � 1 PROVIDED BY PARAGON DISPLAY ]E-31 ELECTRICAL PANELS. WORD WITH 1. I I I I I I I I I I I u —1] 4. _ ELECTRICAL DINGS. ArkrneGcs,Inc.and their Consultants shall be deemed the authors \ \ \ GROUP AND INSTALLED BY GG. and owners of their respective Instruments of Service and shall retain all common law,statutory and other reserved rights,including <IE 2 2. ALL MECHANICAL DIFFUSERS IN ]E-32 BARRIER FREE SIGNS SUPPLIED AND copyrights.The Instruments of Service shall not be used for future IV INSTALLED BY GENERAL CONTRACTOR. SEE additions or alterations to this Project or for other projects,without O DINING AND HALLWAY SHALL BE TOILET ROOM SIGN DETAILS. the prior written agreement of Arkinetics,Inc.Any unauthorized use C PAINTED P-30. of the Instruments of Service shall be at the Owner's sole risk and TYP. TILED WALL ELEVATION r- TILED WALL ELEVATION ELEVATION without liability to Ark'inetics,Inc.and their Consultants NIE-33 OMS BRACKET PROVIDED BY TECH VENDOR arkinetics®2016 - 1/4" = 1'-0" BEVERAGE COUNTER `-'T = C__vi—yNTERIOR 1/4" 1'-0" SERVING /4" = 1'-0" KITCHEN AND INSTALLED BY GG BRACKET TO BE cMOUNTED AT 4'-6" TO BOTTOM BRACKET DRAWING TITLE: 5 NOTE: ALL TILE TO BE INSTALLED WITH 3/I6" NOTE: ALL TILE TO BE INSTALLED WITH 3/16" HOLE. GROUT JOINT. GROUT JOINT. INTERIOR ELEVATIONS IE-34 2'X3' DRY ERASE BOARD PROVIDED BY AND DETAILS 0 TENANT INSTALLED BY GG. O aJ ® BABY CHANGING STATION SIGNAGE PROVIDED AND INSTALLED BY GG. MI JJ K <IE-36> 18x24 CORK BOARD. PROVIDED BY TENANT, INSTALLED BY GC. CP ® ZOUP! CLOCK BY TENANT, INSTALLED BY GC ON CENTER WITH DOOR SHEET#: W 8 A5 . O1 CO .. .. ., ( -.., ) . 6,5 , CLOSURE \ ./ CLOSURE PANEL PANEL KEYED NOTES: GENERAL NOTES. r FREEZER I FREEZER ® DINING FURNISHINGS BY MILLWORK SUPPLIER, TYP. (REFER TO MILLWORKSHOP PRANGS 4 FINISH MATERIAL REFERENCE. 16 CD ® ® INSTALL INSTRUCTIONS). P-** j GOORD WITH ROOM FINISH 7 m O a-71) DINING BOOTHS BY MILLWORK SUPPLIER, TYP, e_a. SCHEDULE. Ib • • (REFER TO MILLWORKSHOP DRAWIGS b f EQUIPMENT REFERENCE. GOORD , I . INSTALL INSTRUCTIONS). }/� • O WITH EQUIPMENT PLAN AND KITCHEN CO = SCHEDULE. , \\ IE-3 WALL BLOCKING BY GEN CONTRACTOR. BEYOND '1 �. (REFER TO MI )HOP DRAWIGS 4 O TOILET ACCESSORIES. \�' ® 1 1 \4 O INSTALLINSTRUCTIONS). SEAL 0 ' L J I Lk ....._..._._ ^ IE-4 CASEWORK PROVIDED BY MILLWORK I. INTERIOR GRAPHICS AND SIGNAGE TI I �r € SUPPLIER AND INSTALLED BY GC - TYP. PROVIDED BY PARAGON DISPLAY Fi' 7 vi I I GROUP AND INSTALLED BY GC. . (REFER TO MILLWORKSHOP DRAWIGS 4 r L i i-_ _ INSTALL INSTRUCTIONS). = w c 64 §2 2. ALL MECHANICAL DIFFUSERS IN ® COUNTERTOPS PROVIDED BY MILLWORK DINING AND HALLWAY SHALL BE EH/ O SUPPLIER AND INSTALLED BY GC - WORD ALL SUPPORT REQ'MTS W/ MILLWORK , 6'.. 5 PAINTED P-30. ,S 45 SUPPLIER. (REFER TO MILLWORKSHOP �f m In o 0 .- °INTERIOR ELEVATION P N T E RI O R ELEVATION DRAWIGS b INSTALL INSTRUCTIONS). 0 °. - u) 1- qj o 1/4" = 1'-0" KITCHEN 1/4" = 1'-0" KITCHEN ■ _ IE 6 WELDED FLANGE W/ EPDXY BOLTED POST p O N N INSTALLATION - WORD SIZE AND LOCATIONS c T c ��. WITH MILLWORK SUPPLIER (TYP). (REFER TO E r L o c+3 . MILLWORKSHOP DRAWIGS I INSTALL 0 0 I N a iL INSTRUCTIONS). + N U) 10'-4' 4'-10" 4'-I0" 6'-O" 10'-4" 4'-IO" 4'-IO' 6-4/_2" IE- C 2 U DESK TOP PROVIDED BY MILLWORK CO - ° 0 -/ /- -/ / / TOOUTLET /- / / / / }' PLASTIC LAMINATE ('WA-4613-60 SAFFRON ■ N CD TO OUTLET TO OUTLET OU LE g- TO OUTLET Srr TO OUTLET EV TO OUTLET TIGRIS') W/ BLACK EDGE. INSTALLED BY GC. CD ° / 3'-0r / <IE-19> -,-----/- -,----,- (REFER TO MILLWORKSHOP DRAWIGS 4 Ilt ,=: ) GATSE GATSE CAT5E RI" TYP. INSTALL INSTRUCTIONS). o r IE $ SHELVES PROVIDED BY MILLWORK COMPANY, 2 0 0 _. t .... 0 PLAM (ALMOND) W/ HD STANDARDS. al 5 0 05 0 O /I \ INSTALLED BY GC: O Cr O w <775-> NETWORK RACK SUPPLIED AND INSTALLED BY M3 ki ti ' BATA DATA DATANETWORK VENDOR. GG TO PROVIDE =,i : crt l2 cn urpresa .._� #1'I #Iq BLOCKING. II _ N N N iii. #21 u _ \ ❑ DMi3 0 — — — — — �M L] -\ rE 7 BLOCKING 4 7 7 BLOCKING $ J I BLOCKING 4 -I I i �j IE 10 KITCHEN EQUIPMENT (TYP) - SEE EQUIP PLAN. ~ LTV BRACKET TV BRACKET I TV BRAKET ! 48" LONG PICTURE LEDGES PROVIDEp BY J E J L J <IE-11> MILLWORK SUPPLIER, INSTALLED BY GG. 18x36 18x36 '' I t I— PROMO : liiPROMO w C1111....... _.W.::.::::.:,::::::::::.: ::. 30"X30" FRAMED PICTURE BY GRAPHICS 18 s- tu \ I� O (3J DATA <IE 12> PROJECT: ® T-2 1 ad SUPPLIER ANp INSTALLED BY GG. - TYP, • w - r .aT�. w ... ---,1 r i DC ori \ 1 r IE 13 MILLWORK CO AND INSTALLED BY GG. ❑ O 10,1 < IX SOLID CHERRY TRIM PROVIDED BY f ti IL w r- o —�i — DATA li 117 1 • II �~l._.._..._.,� 0 0 (Z .p r g_ --_____Al v ""`'".- t ��.._..I IE 14 I SOLID CHERRY CHAIR RAIL. SEE DETAIL X b O -.. I a I rir u i TT ---- --�wwww--_ - _�_ � � __ � rr--,_ � _ z .fl U �,.. .. � T. - ............................. . .:: ON A5.01. tY ._.,._.,._�__._.__.. ._.._._.,..,.. ...._-..--....-. -`T--- -wwww--r ..... .,_.._._ .....,. F —._--- ....,. -- I - ..,... .. .._ _ .. - ,1 .Y 1 - - - - ......._.._.�._....... i _ ,...... ........ wwww--- -- ........_.-wwww- ----- .....,..._7 .,. .W.,�. I ...._:._- c -.. .: 'fl = r .r', \ ) ............ . ......I�.,.. _,-,.,........_..,:._.�. ___. -- �.�.m.m I '.:- j i ;''J• , /' _ `® .� ', ___:L._..._.. �l� .:TI_ 1 :,., --- II -_.. 0 W O lµ �I li I /, _ �� I l FRAMED PHILOSOPHY STATEMENT, INSTALLED d� r � _ . ..._ -'`—.__._._._..-Al1 . '.. ` 1 d1 #? L 8 ='l. ` 0-15) �i ..0 — i SCS f . 7 I._.._ .�-,. *, I 'T....... .... ,. t- 1, -yI �"� P I i , ...." ll I -_ _ -2.":.-4.:‘.._.. __ _.\� I BY GG. O r 1n I !,, l l 1_l i I \ 7 / ({>J �1... w I ��� � '�l l� ` \, _. I _ , \ q I I` `" -- JIl —� \ — _.—./__ —`�--_ 'J I I� OV I I f �/ ' \� _'/ \\_._ J �r i I I5 oVN Po Pi F. 1 — I11 I ., iv \ . / •D , .-.., I i :I 1r _ _ O ALUM/ GLA55 STOREFRONT TO a �; I I I -,,z.IF - - _..' �/ I i `� _�. �: - -- IE 16 EXISTINGCe NJ II � _ r.-�.mm --- 1 -TT �/ n i I t : 11 — REMAIN. \ , I \ \ \ fi I `l \ \ \ \ \ \ 1 I — 6�'� I'-b" br I'-4° 6'-134• OCCUPANCY LOAD SIGNAGE �*'k \ `-1 D z 61 / -24/2' - /2 Je b'�4 6" 2'-O' <IE 17.�' / / / / / / / / .I' O C>c ��- / <IE_18� ZDUP! LOGO PROVIDED BY GRAPHICSZmilivt.\ �. iiilli AS.0I CT1 IE-4> <IE-10— <1E-4)— <IE-33> IE-4 l3J 3/4° catv�UlT w/ PULL su SUPPLIER ANp CLEAT MOUNTED BY GG TO BE W LLIZ O STRING FOR DATA CENTER BETWEEN ADJACENT DOTS. i 0 o z ❑ 1E-19 DIGITAL MENU BOARDS PROVIDED BY ZOUP! - ce I— I--i rt 2 INTERIOR ELEVATION ( ELECTRICAL OUTLET LOCATIONS TO PROVIDE WOOD BLOCKING AND Q Q INSTALL UNITS - GOORD IN/ ELECT DINGS - Z Q 0 3/8" = 1'-0" SERVING l3/g" = _0 SERVING TYP OF (3). _ NOTE: SEE THIS SHEET FOR ELECTRICAL OUT / IE-20 INSTRUCTIONAL SIGNAGE PROVIDED BY Q LOCATIONS. GRAPHICS SUPPLIER AND BULKHEAD MOUNTED (i) BY GC, TYP. O IE-21 ZOUPI VINYL DECALS AND SIGNAGE PROVIDED BY GRAPHICS SUPPLIER AND INSTALLED BY 1-1 GC - COORD LOCATIONS W/ ZOUPI O r-I <T- 3> VINYL GRAPHICS PROVIDED BY GRAPHICS SUPPLIER AND INSTALLED BY GC. <IE-23> NEW VINYL WALL GRAPHIC BY GRAPHICS SUPPLIER AND INSTALLED BY GC. TOILET ROOM GENERAL NOTES: TOILET ROOM ACCESSORIES: <IE-24> 4-1/2" VINYL LETTERS BY PARAGON DISPLAY MARK: ISSUE: DATE: GROUP HUNG BY CONTRACTOR, Review 50% 01/18/16 I, PROVIDE FIRE RETARDANT TREATED (F.R,T.) WOOD BLOCKING IN WALLS AT TOILET - SURFACE MOUNTED 18" WIDE X 36" HIGH STAINLESS SURFACE MOUNTED (VERT) 18" LONG X 1-1/4" DIA SURFACE MOUNTED CLOTHES/HAT HOOK SURFACE MOUNTED 50AP DISPENSER o O 0 O O PROVIDED BY SMALLWARES VENDOR Review 90% 02/05/16 PARTITIONS, GRAB BARS, ETC. AS REQUIRED PER MFR'S RECOMMENDATIONS. STEEL FRAMED MIRROR GRAB BAR WITH PEENED SURFACE W/ CONGEALED MOUNTING FLANGE <IE-25> COKE MACHINE 7RANSLITE PROVIDED BY Property Owner Review 02/23/16 - BOBRICK: B-I65-1836 -BOBRICK: 8-6806.9gX18 -BOBRICK: B-6821 AND INSTALLED BY GENERAL CONTRACTOR GRAPHICS SUPPLIER AND INSTALLED BY GC. 2. COORDINATE PLUMBING FIXTURE TYPES AND FLOOR DRAINS (FD) AND INSTALLATION - MOUNTING HT: BOTTOM EDGE OF REFLECTIVE -MOUNTING HT: 3cI-41" AFF TO CENTERLINE OF BOTTOM -MOUNTING HT: 4'-0" TO HOOK AT BACK OF DOOR Permit Set 03/11/16 RECESSED PAPER TOWEL DISPENSER AND WASTE PROCEDURES WITH APPROVED PLUMBING DRAWINGS AND MFR'S RECOMMENDATIONS. SURFACE AT 40" (MAX) AFF. BAR; 39-41" FROM REAR WALL L <IE-26> OPEN SIGN BY OWNER TO BE INSTALLED BY RECEPTACLE - GC TO SUPPLY SPACER FOR END OF GRAB BAR SURFACE MOUNTED FEMININE NAPKIN DISPOSAL GG - CHAIN MOUNTED FROM UNDERSIDE OF O - BOBRICK15-3q4.2 3. INSTALL SOUND ATTENUATION/BATT INSULATION (MIN 3-Y2" THICK-FULL HT OF WALL) IN SURFACE MOUNTED 36" LONG X 1-I/4" DIA GRAB BAR NOT MOUNTED TO TILE (WOMEN'S ONLY) WINDOW FRAME, PLUGGED INTO SWITCHED ALL TOILET ROOM WALLS (TYP). OO WITH PEENED SURFACE - BOBRIGK: B-254 -PAPER TOWEL DISPENSER TO BE MOUNTED AT OUTLET AT STORE FRONT. -BOBRICK: B-5806AclX3b O SURFACE MOUNTED SINGLE ROLL TOILET TISSUE - MOUNTING HT: ALIGN WITH TOP OF TOILET TISSUE 48 AFF 4. ACCESSIBLE TOILET FIXTURES AND INSTALLATION SHALL CONFORM TO LOCAL -MOUNTING HT DISPENSER DISPENSER <IE-27> FLOOR SINKS - WORD W/ PLUMBING DINGS, ACCESSIBILITY GU4PELINES. -BOBRICK: 8216851 TYP. SURFACE MOUNTED 42" LONG X 1-1/4" DIA GRAB BAR -MOUNTING HT: 20" AFF TO ROLL GL. O BABY CHANGING STATION 5. ACCESSIBLE COMPLIANT LAVATORIES SHALL HAVE INSULATED DRAIN PIPES AND HOT O WITH PEENED SURFACE -MOUNTING LOCATION: 36" MAX FROM TOILET WALL SEE EQUIPMENT SCHEDULEIE-28 PLUMBING CONTRACTOR TO INSTALL WATER WATER PIPES PER ACCESSIBLE GUIDELINES. -BOBRICK: B-5806.'9X42 TO FRONT EDGE FILTER SYSTEM, SUPPLIED BY EQUIPMENT -MOUNTING HT: 36" AFF TO CENTERLINE VENDOR. 6. ALL ACCESSORIES SHALL BE MOUNTED PER THE MANUFACTURER'S RECOMMENDATIONS AND PER ACCESSIBLE GUIDELINES. IE 29 PENDANT LIGHT, TYP - GOORD WITH ELECTRICAL DINGS. IE-30 NEW DOUBLE-ACTING DOOR. GOORD WITH PROJECT#: 15085.01 RUN TILE DOORFRAME SCHEDULE. TYPICAL TOILET ROOM ELEVATIONS ALONG SIDES DRAWN BY: DKN 1 CHECKED BY: DJB SCALE: 1/4" = 1' 0" AND TOP OF �� IE 31 ELECTRICAL PANELS. WORD WITH TOWEL ELECTRICAL DINGS. Arkinetics,Inc.and lila:oiso:ufltants shall be deemed the authors \ •q • 'SING DISPENSER -- - - and owners of their Instruments of Service and shall IE 32 BARRIER FREE SIGNS SUPPLIED AND retain all common ry and othereservedrights, ncludingSWITCH, O "PLEASE WASH 0 0 , . copyrights.TheInsService shall not Ix used for future N P-26 I -O INSTALLED BY GENERAL CONTRACTOR. SEE additions or alterations to this Prefect or for other projects,without = GOORD. W/ O YOUR HANDS" 3,_6r the prior written agreement of Arkinetks,Inc.Any unauthorized use ELEC. PHGS. SIGN BY TENANT MAX TOILET ROOM SIGN DETAILS, of the Instruments of Service shall be at the Owner's sole risk and without liability to Arkinetics,Inc.and their Consultants C P-26 2 © © 3-O' O / / / J / AND INSTALLED -1 /- 3'-4" arkinetics®2016 N / • ►��--moi <1E-33> OMS BRACKET PROVIDED BY TECH VENDOR BULLNOSE / X ; © / BY GG. O 1�'-O"/ O \ ,�' / CO ANp INSTALLED BY GG BRACKET TO BE —I iwwwwwwwwww■ simum sw■ —�' 2 , o Q w .All3 --� —■ MOUNTED AT 4'-6' TO BOTTOM BRACKET DRAWING TITLE: aswwwwwwwwwwwwwww 4 Q ww■ ■ww HOLE. c� ® ;wwwwwww..w-=wwww■ 1_ u o a i- r , .... . •==■ ' \ -t \ INTERIOR ELEVATIONS +wwwwwwwwwwwwww bC iws�.wwwwwwwwwwww■ ■ • ■ ■ r h www wws - ACCENT ■lwwwwwwwwwwwwwww x - - - - �`! -w■ ■ww ( 1 \ �] .wwwwwwwwwww■asww.s■ _ _ www wws yr a IE-3- 2'X3' DRY ERASE BOARD PROVIDED BY o .,.--wwww=■.wwww== w \ n w—. .ww t _ _ _ _ O ,�, r AND DETAILS 1wwwwwwwwwwwwwwws _I O www ww■ TENANT INSTALLED BY GG. O ® a swwww■I■wwwwwwwww— r \ ww■ ■ww O �i • -• O I "T_ �i wwwwwwwwwwwwwwwws ww�� wwilw� r — MN as��wwwww—w--wwww \ r r `lwwwws.wwwwwwwwww■ www ww■ r lf1Pj aswwwwwwwwwwwwwww --wwww-- .. h m ;.7C), 40 z7A7). ® BABY CHANGING STATION SIGNAGE PROVIDED •■■■■■■j■•••••■ v I \ ■■■���� �i f l AND INSTALLED BY GC. M ® \ \ 1 \ \ \ \ -'t \ XJ COVE BASE I/8" GROUT LINES FOR RESTROOMS I/8" GROUT LINES i _b„ 4" Milt HORIZONTAL VERTICAL FOR RESTROOMS / I'-6" PREFERRED ,, �, OE IE-36 18x24 CORK BOARD. PROVIDED BY TENANT, 42 WORD WITH EQUIPMENT PLAN FOR EXACT MODEL 1 / (i'-3" MINIMUM) MAX INSTALLED BY GG. m TYP. ALL WALLS RESTROOM SIDE FRONT SIDE FRONT SIDE CO ZOUPI CLOCK BY TENANT, INSTALLED BY DIAPER RECESSED GC ON CENTER WITH DOOR SHEET#: `t' FINISHES CLOTHES HOOK '' CHANGING DISPENSER, `LAVATORY SHIELD SAFETY COVERS AS MTE: EXPOSED HOT WATER IANUFACT1URED BY PLUMBERENE AND DRAIN PIPE TO BE �SPEGALTVERED IY HANDYTOILET) PRODUCTS: PALM SPRINGS, CA. 92263-1684 I-(800)-475-8629 OR EQUAL. 3 0) A 5 • 0 2— .. T KEYED NOTES: IE-1 DINING FURNISHINGS BY MILLWORK SUPPLIER, TYP. (REFER TO MILLWORKSHOP DRAWIG5 4 INSTALL INSTRUCTIONS). <IE-2> DINING BOOTHS BY MILLWORK SUPPLIER, TYP, 4._._. -� (REFER TO MILLWORKSHOP DRAWIG5 8 INSTALL INSTRUCTIONS). ..-- 4D5) .® WALL BLOCKING BY GEN CONTRACTOR. (REFER TO MILLWORKSHOP DRAWIG5 4 INSTALL INSTRUCTIONS). SEAL IE-4 CASEWORK PROVIDED BY MILLWORK SUPPLIER AND INSTALLED BY GC - TYP, (REFER TO MILLWORKSHOP DRAWIG5 4 INSTALL INSTRUCTIONS). IE< -1.> COUNTERTOPS PROVIDED BY MILLWORK SUPPLIER AND INSTALLED BY GC - WORD CAc ti.)- ALL SUPPORT REQ'MT5 W/ MILLWORK 41) 2 SUPPLIER. (REFER TO MILLWORKSHOP ° o o o r D0 RAWIG5 4 INSTALL INSTRUCTIONS). c a) _c 1- r o co to IE-6 WELDED FLANGE IN/ EPDXY BOLTED POST 0 0 N N INSTALLATION - WORD SIZE AND LOCATIONSlig ; E esj WITH MILLWORK SUPPLIER (TYP). (REFER TO MILLWORKSHOP DRAWIG5 4 INSTALL0 0 .fs OU o N J Iz L . a.INSTRUCTIONS). + N 6 <1 > DESK TOP PROVIDED BY MILLWORK CO - a }O PLASTIC LAMINATE ('WA-4613-60 SAFFRON �) C TIGRIS') W/ BLACK EDGE. INSTALLED BY GC. '— (REFER TO MILLWORKSHOP DRAWIG5 8 a cy) (---2) 0 r � A r L.( INSTALL INSTRUCTIONS). L E .. . . ...„ a> ,. • -'-r IE-8 SHELVES PROVIDED BY MILLWORK COMPANY, = c U oo Q PLAM (ALMOND) W/ HD STANDARDS. [E 21� INSTALLED BY GC. O cC Ocr, ai BUILDING SIGN BY OTHERS IE 23 BUILDING SIGN BY OTHERS IE 9 NETWORK RACK SUPPLIED AND INSTALLED BY 0 c c BLOCKING. VENDOR. GC TO PROVIDE - > CD co > ( N IE-10 KITCHEN EQUIPMENT (TYP) - SEE EQUIP PLAN. I_ J <1L.> 48" LONG PICTURE LEDGES PROVIDED BY MILLWORK SUPPLIER, INSTALLED BY GC. 1 ���/ gy`� ���� 7�� ii//i 7�� ���� ��7 7�� 30"X30" FRAMED PICTURE BY GRAPHICS IE-26> IE 12 PROJECT: SUPPLIER AND INSTALLED BY GC. - TYP. i T ! 24x36 4x 6 i i . .. r 4x3f 10140 IX SOLID CHERRY TRIM PROVIDED BY ` , (//' MILLWORK CO AND INSTALLED BY GG. + 1 , I tKT' I 9'KT'G j MKT'r IE 13 I / i AREA ,AREA COLUMN BEYOND AREA \ I A � —; I IX6 SOLID CHERRY CHAIR R SEE DETAIL/ 1 •I / \ r `' IE 14 AIL. ( I —J \)/ . - \ ON A5.01, CC o Lu ! I '' PHILOSOPHY STATEMENT, INSTALLED } ! i , _ _ - _ - y IE-15 BY GG 1, : .. .. /� Q UJ D no i i i I \ \ / IE-1 EXISTING ALUM/ GLASS STOREFRONT TO ce d [V J 7 I \ -i' / REMAIN. M Q V, N ® OCCUPANCY LOAD SIGNAGE kYil. N _ 6). Cal IE-20 IE-21 ® ® IE-20 I \\LIE-21> VIE-2Z3 pC • •E-18 ZOUP! LOGO PROVIDED BY GRAPHICS o • SUPPLIER AND CLEAT MOUNTED BY GC TO BE114 CC z O CENTER BETWEEN ADJACENT DOTS. a EXTERIOR ELEVATION EXTERIOR ELEVATION O 0 z d. IE-19 DIGITAL MENU BOARDS PROVIDED BY ZOUP! - z ~ _ R 1/4" = 1'-0" STOREFRONT WEST 1/4" = 1'-0" STOREFRONT WEST • < > GG TO PROVIDE WOOD BLOCKING AND � z C/') INSTALL UNITS - COORD W/ ELECT DINGS - r-i Q ,__I TYP OF (3). V) IE-20 INSTRUCTIONAL SIGNAGE PROVIDED BY Q GRAPHICS SUPPLIER AND BULKHEAD MOUNTED > V) BY GC, TYP. O ® ZOUPI VINYL DECALS AND SIGNAGE PROVIDED 1-1 BY GRAPHICS SUPPLIER AND INSTALLED BY 0 O GC - COORD LOCATIONS W/ ZOUPI 1 -1 <T > VINYL GRAPHICS PROVIDED BY GRAPHICS SUPPLIER AND INSTALLED BY GC. <72-3) NEW VINYL WALL GRAPHIC BY GRAPHICS SUPPLIER AND INSTALLED BY GC. IE-24 4-1/2" VINYL LETTERS BY PARAGON DISPLAY MARK: ISSUE: DATE: GROUP HUNG BY CONTRACTOR. Review 50% 01/18/16 Review 90% 02/05/16 ® COKE MACHINE TRANSLITE PROVIDED BY Property Owner Review 02/23/16 GRAPHICS SUPPLIER AND INSTALLED BY GC. Permit Set 03/11/16 IE-26 OPEN SIGN BY OWNER TO BE INSTALLED BY GG - CHAIN MOUNTED FROM UNDERSIDE OF WINDOW FRAME, PLUGGED INTO SWITCHED OUTLET AT STORE FRONT. ® FLOOR SINKS - GOORP IN/ PLUMBING DINGS, TYP. <1E-28) PLUMBING CONTRACTOR TO INSTALL WATER . FILTER SYSTEM, SUPPLIED BY EQUIPMENT VENDOR. IE-29 PENDANT LIGHT, TYP - GOORD WITH ELECTRICAL DINGS. E-30> DOOR/FRAMENEW ASGHEDULE.CTING OR. WORD WITH PROJECT#: 15085.Di GENERAL NOTES. DRAWN BY: DKN CHECKED BY: DJB ® ELECTRICAL PANELS. GOORD WITH FINISH MATERIAL REFERENCE. ELECTRICAL DINGS. Arkinetics,Inc.and their Consultants shall be deemed the authors P-** ) GOORD WITH ROOM FINISHand owners of their respective Instruments of Service and shall SGHEDIILE. retain all common law,statutory and other reserved rights,including IE 32 BARRIER FREE SIGNS SUPPLIED AND copyrights.The Instruments of Service shall not be used for future N INSTALLED BY GENERAL CONTRACTOR. SEE additions or alterations to this Project or for other projects,without 00 EQUIPMENT REFERENCE. WTOILET ROOM SIGN DETAILS ORD the prior written agreement of Arkinetics,Inc.Any unauthorized use c • . of the Instruments of Service shall be at the owner's sole risk and WITH EQUIPMENT PLAN AND without liability to Arkinetics,Inc.and their Consultants N SCHEDULE. IE 33 OMS BRACKET PROVIDED BY TECH VENDOR arkinetics©2016 AND INSTALLED BY GG BRACKET TO BE W * TOILET ACCESSORIES. MOUNTED AT 4'-b" TO BOTTOM BRACKET DRAWING TITLE: _-I HOLE. EXTERIOR ELEVATIONS D I. INTERIOR GRAPHICS AND SIGNAGE :0 IE-34 2'X3' DRY ERASE BOARD PROVIDED BY 0 PROVIDED BY PARAGON DISPLAY TENANT INSTALLED BY SC. O GROUP AND INSTALLED BY GG. 73 -) 2. ALL MECHANICAL DIFFUSERS IN <IL> BABY CHANGING STATION SIGNAGE PROVIDED DINING AND HALLWAY SHALL BE AND INSTALLED BY GG. m PAINTED P-SO. IE-36 18x24 CORK BOARD. PROVIDED BY TENANT, -7I INSTALLED BY GC. CP m ® ZOUP! CLOCK BY TENANT, INSTALLED BY W GG ON CENTER WITH DOOR SHEET#: j I 8 ROOM FINISH SCHEDULE DOOR SCHEDULE ROOM ROOM FLOOR BASE WALL CEILING REMARKS ROOM xxx DOOR NUMBER NAME MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH NUMBER FRAME MISCELLANEOUS CPT-1 HRDWRE {HEAD NORTH SOUTH EAST WEST NO. TYPE LOCATION MATERIAL SIZE THICKNESS FINISH TYPE MATERIAL FINISH RATING THRESH 1 REMARKS NO. EXIST WDF-I NEW GYP NEW GYP EXIST - AC2 COORD WALL FINISHES W/ INTERIOR ELEVATIONS SET NO HEAD JAMB 100 SEATING AREA GONG CPT-IGPT-2 $2 BD BD GYP BD / C-26 - T5-I AT VINYL TO CARPET TRANSITION 100 EXIST NEW GYP NEW GYP NEW GYP AG2 EX-I - SEATING 100 ALUM - PREFINISHED EXTG - PREFINISHED - I - - - EX-I 101 QUEUING GONG WDF-I B2 BD BD BD /' '/' - COORD WALL FINISHES W/ INTERIOR ELEVATIONS 101 - - 5 d r EXEX-2SEATING 100 ALUM PREFINISHED EXTG - PREFINISHED - t_,.,r.- '' tti l EXIST NEW GYP NEW GYP NEW GYP NEW GYP A2 - - EX 2 /�.^�` - 102 HALLWAY GONG WDF-I E3-.2 BD BD BD BD C-2 102 EX-3 - KITCHEN 105 ALUM - PREFINISHED EXTG - PREFINISHED - 3 - - - PAINT DOOR/ FRAME EX-3 EXIST T-...2/".NEW GYP NEW GYP NEW GYP NEW GYP AG- 103 SERVING VCT-I _ - 103 " 8D BD BD D C.COORDINATE WITH INTERIOR ______._...____....... ---_.._..__._ _.-........_.._.__...._._______-.___-.._._....._.______._.__--.-._._-.._.....___..__._._....___....__._..__......- _-__..____.__._._...___._.._-____..._..._.__..___...___.........._..__...._.__ SHEETS 12 __._._-_....._._........._._......._._.-....______...._._...___..____._.___.__...._.___.______._..__.__._....__.__.__-_._...............___..___._....__.____._.._..._..-......__..__._..__....____._.___...,..._.__._.___._ - - ELEVATIONS,S EE 5 A5.0 _.._ __._..___.___...____._..-_.___......._..._..................._._.___._....__._..___.___.....______..._....._.__......_._...__...----....__.__...__._......__..._..._.__._._..-.._�................___...._...._..-__........._.._..._._.._._..._.._......._____..._.._ ....._.__..........___.....__._..._.........._....._..._....._.___.._............ ..___.___._........_..._....__.............__._._-__.._....___....._..._.__....___ _..........................._..... ........._......._._...._ • J EXIST NEW GYP NEW GYP NEW GYP NEW GYP AG- ____._..._._......._._.._ __.__._....____...____._____.._._.._____.__ 105 KITCHEN C..ONC VGT B-I BD BD BD BD .....----AC-23 105 SEAL EXIST 'YF' e vYF' B vYP E3 5YP 5I2 NEW COORD WITH TOILET ROOM ELEVATIONS 101 DA2 SERVING 103 TO KITCHEN 105 ALUM W/VISION LITE 3-4" x 1'-0" RO 1-3/4" PREFINISHED DI HM PAINT - 2 106 WOMEN'S ROOM GONG WDF-I T-I T-I T-I T-I - _1 GYP BD P-26 CAP WALL TILE IN/SCHLUTER TO MATCH SERVING AREA 106 _ - H.2 J2 DOUBLE ACTING DOOR 101 107 MEN'S ROOM EXIST WpF-I T-I ''YF' B vYF 13 .vYh' a ,' F' $ NEW P 26 CDORI� WITH TOILET ROOM ELEVATIONS LOT 10.2 F WOMEN'S RESTROOM 106 S.C. HOOD 3'-0" X 1'-0" 1-3/4" STAIN I HM PAINT - 4 - HI JI 102 GONG T-I T-I T-I T-I GYP BD CAP HALL TILE W/SCHLUTER TO MATCH SERVING AREA _ _ 103 F MEN'S RESTROOM 101 S.C. WOOD 3'-0" X 1'-0" 1-3/4" STAIN 1 HM PAINT - 4 - HI JI 103 1 DOOR NOTES: HARDWARE SETS: .�, CD N ALL PAINT FINISH TO BE EGGSHELL UNLESS OTHERWISE NOTED I. ALL HOLLOW METAL AND HOOD DOOR FRAMES HARDWARE SET NO. 1 HARDWARE SET NO.4 0 ■� 0CA W dam' ch U SHALL BE PAINTED BLACK WITH SEMI-GLOSS 2I CC) (.0 BUTT HINGES M MN W -2 FINISH MATERIAL SCHEDULE FINISH NOTES: FINISH. SEE FINISH NOTES FOR ADDITIONAL - NEW CYLINDER LOCK - PRIVACY VER LOCKSET p O N N INFORMATION. - NEW CLOSER (2) N - PANIC DEVISE (2) - 12" HIGH STAINLESS STEEL KIGKPLATE o E - w—Fa LOCATION CODE MATERIAL MANUFACTURER PRODUCT NO. DESCRIPTION/REMARKS I. ALL MATERIALS AND FINISHES SHALL BE NEW UNLESS NOTED 2. ALL DOOR HARDWARE, HARDWARE FUNCTIONS (BOTH SIDES) 41) O o 5 OTHERWISE. - WALL STOP > U N -I 11. ii CPT-1 CARPET SHAW C ;FE r,PATCRAFT ZQJP1 QTR N0 T657L ZIP CPT'IL 24"X24", I1GTALLA11QN CUARTER TUM AND HARDWARE FINISHES SHALL BE REVIEWED HARDWARE SET NO.2 Cl) CWITH THE TENANT BY THE GENERAL - MEN/WOMEN ACGE551BLE SIGNAGE RF:ASE AL C 1t�t•1-LIVE T1� 2. ALL FINISHES NOT SPECIFIED SHALL BE SELECTED BY TENANT - ALL HARDWARE BY DOOR SUPPLIER 22 U 0.5TGM CADET TILE STYLE: EXPERIENCE PATCRAFT FER MANI. A11GN5CONTRACTOR,UNLESS OTHERWISE NOTED. (SEE SIGNAGE DETAILS THIS SHEETCL CLBT T6b3C-0 AND APPROVED BY THE ARCHITECT. - 12" HIGH STAINLESS STEEL KIGKPLATE (BOTH - DOOR CLOSER • Q} CONTACT: 3. PROVIDE FLOORING TRANSITION STRIPS WHERE REQUIRED AT 3. ALL NEW WOOD DOORS SHALL BE STAIN SIDES) ;J o ACFEEIVE: ZCLP CARPET TILE Ai-LIVE KYLE QJNAJ Q=PATCRAFT GRADE, ROTARY CUT, BIRCH VENEER FINISH TO °� i FLOOR MATERIAL CHANGES. HARDWARE SET NO. 3 0 � � IO CRAI^8222Z DALTON 0130722 MATCH CHAIR RAIL, SEE 5T-I AND 5T-2 FINISH HARDWARE SET NO. 5 _ - NEW CLOSER 0) CIaTA 2CCCMGGT: (0241-4014 4. INSTALL ANTI-FRACTURE MEMBRANE (NAC PRODUCTS, INC - ECB SCHEDULE - NEW CYLINDER LOCK - NEW CYLINDER LOCK0 _ MaLE ) 34 MEMBRANE OR APPROVED EQUAL MIN 36") OVER ALL EXISTING 4, SEE SPECS SHEET 01.01 FOR ADDITIONAL ' NEW L2" STAINLESS STEAL KICK PLATE - NEW CLOSER DOOR TYPES: 1. E 1 0) -0 0 0 EMAIL: K LELI.NAJSPATCRAFT.CGM SLAB CONTROL JOINTS, CRACKS, ETC. IN AREAS WHERE NEW HARDWARE INFORMATION - NEW PANIC HARDWARE PEEP HOLE MAY c15 v p = o�U c CERAMIC TILE AND VCT 15 TO BE INSTALLED. - DOOR PULL OCCUR, SEE a 0 - O r. CCPT-21 CARPET IAWCA TjPATCRAPF 7l R CRIDER ND T6561.MP CPT EL PLEAEE f3RCI-AEE ALL ELLEJACH5VE TFR0J5-1 5, CHASE DOORS CONTACT INFO: /� DOOR SCHEDULE v "' a� ` -- a mt J PATCRAFT MAJ�I.F AT1a 5. ALL VCT FLOORS TO BE FINISHED WITH (3) GOATS OF WAX. VINYL CHASE DOORS, ATTN ANN SPANDREL \` ~ C Ccts ti r~ STYLE: IC831 TE ,4EC.C�^Y S 6 mi PLANK TO BE FINISHED PER MFR. RECOMMENDATIONS. 10021 COMMERCE PARK DRIVE DOOR �`�° a) n- 6- F C .E 'I CONTACT: CINCINNATI, OH 45231 HARDWARE, SEE ; � � I 5 a) N a) KYLE WislAd GF PATCRAFT 6. NOT USED. UNITED STATES OF AMERICA o - -__= DOOR SCHEDULE ," Q o co U CL: t.i COLR 00713 KEYSTQ' Ft)CRAAER228,DALTON 565 30722 (513) 603-2125 ALL HOLLOW METAL AND WOOD DOOR FRAMES SHALL BE CIJSTQ�CCNNEGT: (&0241-4014 INSULATED 55 KIGKPLATE ACh {VE: EFeL E.CUE, MALE. (586)-7,5-4634 PAINTED BLACK, SEE FINISH NOTES FOR ADDITIONAL 6. ALL DOORS NEED TO BE INSPECTED AND TEMPERED MAY OCCUR, SEE 1 8 -IT� ER EMAIL: Kl'I.E.QNAJPATCRAFT.CCM INFORMATION, REPAIRED IF NEEDED. /I GLASS r--- -� 1 DOOR SCHEDULE FLOOR (WDF 1 VINYL COMPOSITE PLANK PATCRAFT ZCUP!Gf�C$Z NO 120017.0Y VINYL Pl EAEJ=Fi. CE ALL C�J,E1At:4 LVE 8. ALL DOOR HARDWARE, HARDWARE FUNCTIONS AND HARDWARE PROJECT: ` J RANG PATGRAFTFt3ZMAN,F ¶ FINISHES SHALL BE REVIEWED WITH THE TENANT BY THE GENERAL FULL GLASS FLUSH CONTRACTOR,UNLESS OTHERWISE NOTED. CC. ACCESSIBLE 0 0 STYLE: Imo/HO-LAND FCRMCCNTAGT: b' ROOM 0 CCLCR 20700WaLJT KYLE q 41CFPATCRAFT /y"0.C. DOOR HARDWARE: I IDENTIFICATION FRAME TYPES. �• DR WIDTH a WDTN: 4" PO X2128,DALTCM GA E0722 , 5' SIGN . IAEAR LAYER 20 ML C,USTCNER CQ�LT: (e00)241-4014 / / ALL DOOR HARDWARE ITEMS SHALL BE AS FOLLOWS OR ARCHITECT / SYMBOL "MEN" OR "WOMEN", ,-.... --7 - vc;BLE: (5?6)2 5-46'x} 4-1/2" HIGH; COLOR: WHITE APPROVED EQUAL UNLESS NOTED ON DOOR HARDWARE SCHEDULE: ��.� r O W A VE: 41C°S-IAW VINYL 19-"AND EMAIL: KYLE.G.N d PATCRAFT.CQH `'.._ ..) CLEAR ACRYLIC •0 0 CTL' TILE ME DOOR HINGES INTERIOR DRS UNO; HAGAR BBIIgI f GLAZING SET IN ry I�- C[ '• (VCT-1) VINYL COMPOSITE TILE PATCRAFT ZCUP1 CRDER NO: O205V MP VINYL TL 18' X 18" STAINLESS STEEL X 4Y W/ BLACK RUBBER LTJ NON-RISING REMOVABLE PINS `BABY CHANGING C MOLDING p� Cy N SYMBOL "HANDICAPPED", DOOR HINGES EXTERIOR DRS UNO; HAGAR B$1111 IDENTIFICATION SIGN (BY x CNN... STYLE: CrX�.�l CRETE GQ�1'AGT: I— CQLR CJ a2O5JN T KYLE L1JNAIQ=PATCRAFT u-------- 3-1/_2" HIGH; COLOR: WHITE STAINLESS STEEL X 4/. NRP O M Q 1 FO DRAIAR228,DALTON GA 30722 kl - LOGKSETS: in GG) ACCESSIBLE ROOM NAA-ESIVE: 4100 5-WW VINYL RANG AND CUSTC C. MECT: (&0241-4014 dJ \ STOREROOM/CLOSET SARGENT 28 65504 KL 26DIDENTIFICATION SIGN, ALT (114,44‘kA, 2�� '�r CLASSROOM SARGENT 28 65637 KL 26D 55 KIGKPLATE $ (/) a TILE ELLE MOLE: (530 255-4634 �. LOCATION EMAIL: KYLE.CLNA,IPATOWT.CCM -�- -- _-� ENTRANCE/OFFICE SARGENT 28 65605 KL....260 ---- (BOTH 51DE5) W Z V "WOMEN" 1/32" RAISED PRIVACY/BATHROOM SARGENT 28 651)65 KL 260 -- 11010 TRANSITION STRIP JOHNSONITE BROWN 110 CTA-40-D-USE AT CARPET TO VINYL ' WO M E UPPERCASE, 5AN5 SERIF PASSAGE SARGENT28 651)15 KL 26D t �._ __._�. • 0 Z d TRANSITION TYPE 5/8" HIGH. EXIT/COMMUNICATING SARGENT-28 65615-3 KL 26D �' I— _ LATCH SIDE CHASE DOOR HM DOOR FRAME ( V) v)8-1 ) VINYL COVE BASE ARMSTRONG BLACK 6" \ \ GRADE2 LEVER TYPE - INTERCHANGEABLE CORES BRAILLE FOR OF DOOR SINGLE LEAF SD2000 BASE - EITHER "MEN" OR "WOMEN". LATCH PROTECTION PLATE HAGAR 34@ U532D Z < L9 8-2 l VINYL COVE BASE ARMSTRONG BROWN 110 4 THUMBTURN CYLINDER ADAMS RITE 4066 150 (442 0 t= rizt r �^ DUST PROOF STRIKE HAGAR 28OX US260 FRP-1) FIBERGLASS REINFORCED MARLITE P-118 ALMOND KITCHEN AREA - RESTROOM ID SIG NAGE MORTISE LOCKSET SARGENT 8251 LNB 32P POLYESTER PANELS A5 NOTED MORTISE CYLINDER SARGENT 4126D Q CERAMIC WALL TILE DALTILE RITTENHOUSE SQUARE: ALMOND 0135 GROUT: MAPEI FLEXCOLOR CO 3"=1'-0" WALL MOUNTED ADA-READY ROOM ID. DEADBOLT LOCK ADAMS RITE M518505 il V)C T 1 ' 1 RESTROOM WALLS COLOR: WHITE 00 BACKGROUND COLOR: BLUE, TEXT AND DEADBOLT LEVER ADAMS RITE 4550 O 013536MODIP4 - 3X6 TILE CGNTAGT: SYMBOL COLOR: WHITE. MOUNTING HEIGHT ("LOCKED" OR "OPEN" INDICATOR) TYPE-X GYP BD ON MTL STUDS, TYPE-X GYP BD ON MTL ,q' P 01355436c1MODIP2 - 3X6 BULLNOSE AATICNAL PCCON1B SJI T C TO BE 4-6" FROM BOTTOM OF FINISH NIGHT LATCH (DOOR GUARD) HAGAR 2'14D (INCLUDE-214B) U526D O SEE LANS FOR FURTHER STUDS, SEE PLANS FOR C INFORMATION. 0135A36011PI - 6" COVE BASE E: �'� AL�LJ=.GQM FLOOR TO BASELINE OF BOTTOM PROTECTION (KICK) PLATE HAGAR 1105 15520 FURTHER INFORMATION. v--1P: 871-556.5128CR24-301-34013 CHARACTERS. PROTECTION PLATE UPGRADE HAGAR 1135 - 3 SIDED BEVEL U532D ACCENT TILE: KEYSTONE FGR ALISTAN:E WTH P+RCUGT AVALAEILJTY, SADDLE THRESHOLD NATIONAL GUARD PRODUCT - 424 CONT MTL RUNNER. TURNIP OR CONT MTL RUNNER. TURN UP D31111M5IP - !XI M5 D311 BLACK SFECIAL MCA*INTEIslATICNALSAL 55CR TO 6" WALL BUMPER HAGAR236W I/ DOWN 4" AT JAMBS AND 'ITA f Gfd:HZ / FLOOR STOPS HAGAR 24IF !2• FASTEN WITH SCREWS. y2• OR DOWN 4" AT JAMBS AND FASTEN WITH SCREWS. ITEMS: CHAIN DOOR CHECK HAGAR 300D AI VIRGINIA TILE: STEVE REINIG 1 "p G, SEALANT, TYP EA SIDE. SEALANT, TYP EA SIDE. GTI #50155 ZOUP 6X24 FIELD TILE - ILb45F/GTN GASKETING SET NATIONAL GUARD PRODUCT - 160 V _ T I_� • CERAMIC WALL TILE IN DIRECT LINE 248-4"16-"1850 X2335 / / SYMBOL MEN OR WOMEN , DRIP CAP NATIONAL GUARD PRODUCT - 16 A c`1 L�yCr FIRE-RETARDANT TREATED 2x WD ry Al L�C�j FIRE-RETARDANT TREATED T 2 CTI #50156 ZOUP 12X24 FIELD TILE - 15.52 SFJCTN MOBILE LINE: 248-388-6140 \ HEADER. SERVING AREA AND AT 4-1/2" HIGH; COLOR: WHITE SWEEPS NATIONAL GUARD PRODUCT - 200NA — MARK: ISSUE: DATE: BEVERAGE COUNTER CTI #50151 ZOUP 6X12 COVE BASE - 1.2 EA./GTN EMAIL: ZOUPTILEMGMAIL.COM •• • 2x WD HEADER. HYM BRIG525 - HYDROMENT GROUT MECHANICAL KEY PAD SCHLAGE CO-200 uu ui Review 50% 01/18/16 Ib GA MTL DOOR FRAME. Ib GA MTL ODOR FRAME. 90% HYM - COLOR: BRICK - SANDED GROUT 25# BAG \ 0 CLOSERS - STOREROOM/STOREFRONT Review 02/05/16 STANDARD ARM SARGENT 1431 0 "-� WD OR MTL DR. RABBET SIZE TO z DOUBLE ACTING DOOR. Property Owner Review 02/23/16 ( P-20 PAINT BENJAMIN MOORE HG-I60 KNOXVILLE GRAY SYMBOL "HANDICAPPED'", STANDARD ARM SARGENT 1431 N (HOLD OPEN) 8 BE I'5ifb" FOR 13/4" DR OR I1(6" FOR Cu Permit Set 03/11/16 P-21 PAINT BENJAMIN MOORE 2112-10 COPPER CLAY P-22 • 6,„,-- 3-1/2" HIGH; COLOR: WHITE STANDARD ARM SARGENT 1131 (HOTEL GUEST ROOMS) w 13/a" DR. SEE PLANS AND SGHED to WALL t '� DEEP REVEAL SARGENT 1431 OZ et to FOR SWING DIRECTION, DR SIZE D g ( � PAINT BENJAMIN MOORE 2158 20 VENETIAN GOLD • 453 CLOSER - HEAVY DUTY SARGENT 351 PSH EN AND TYPE. P-23 ) PAINT BENJAMIN MOORE READY MIXED NAVAJO WHITE ...,. 2" •� MANUAL• FLUSH HAGAR 305 AND 33E US26D P-24 PAINT BENJAMIN MOORE HG-8q NORTHAMPTON PUTTY -1 / 1 MANUAL BOLTS HAGAR 282D U526D -- - "MEN" 1/32" RAISED PANIC HARDWARE (EXIT DEVICE) SARGENT 3828 F EN P-25 ' PAINT BENJAMIN MOORE 2111-20 BLACK-BERRY ;;, MEN_____________ EN---�"`J UPPERCASE, SANS SERIF PANIC (EXIT DEVICE) TRIM SARGENT28-K-LL26D DOOR HEAD DETAIL DOOR HEAD DETAIL n TYPE 5/8" HIGH. PANIC HARDWARE (UPGRADE) VON DUPRIN 18/11 SERIES P-26 PAINT BENJAMIN MOORE HC-21 DUNMORE CREAM _ GRADE 2 BRAILLE FOR AUTO FLUSH BOLTS 1-1/2" = 1'-0" 1-1/2" = 1,-0" P-27 ) PAINT BENJAMIN MOORE HC-I01 NORWICH BROWN EITHER "MEN" OR "WOMEN". HOOD DOOR HAGAR-211D1)532D P-28 " PAINT BENJAMIN MOORE HC-1I HASBROUCK BROWN METAL DOORS DOORHAGACONTROLS LS INT.DOOR CONTROLS INT. b12 PC P-30 PAINT RUST-OLEUM FOSSIL - SATIN FINISH RESTROOM ID SIGNAGE ASTRAGAL NATIONAL GUARD PRODUCT 131 SERIES MATCH DR COLOR TYPE-X GYP BD ON MTL STUDS, SEE ST-1 '1 STAIN ML CAMBELL MLC CHARCOAL AFTER STAIN 15 DRY (I) COAT CLEAR 3"=1'-0" WALL MOUNTED ADA-READY ROOM ID. PEEP HOLE (DOOR VIEWER) HAGAR 1115 U526D PLANS FOR FURTHER INFORMATION. WOODSONG II WS2-5125 SANDING SEALER 4 (2) COATS CLEAR BACKGROUND COLOR: BLUE, TEXT AND SATIN FINISH, SAND BETWEEN COATS WITH SYMBOL COLOR: WHITE. MOUNTING HEIGHT DR HARDWARE SUPPLIER SHALL REVIEW ALL HARDWARE FUNCTIONS W/ FIRE-RETARDANT TREATED-2x HD PROJECT#: 15085.01 ST-2 GLR. COAT POLY FINISH SHERWIN WILLIAMS V84F82 320 GRIT TO BE 4'-6" FROM BOTTOM OF FINISH BUILDING OWNER PRIOR TO SHOP DRAWING SUBMITTALS. STUD WITH MTL STUDS AT JAMS. � `I FLOOR TO BASELINE OF BOTTOMTYPE-X GYP BD ON MTL STUDS, DRAWN BY: DN CHECKED BY: DJB AC-22 VINYL CEILING PANEL USG VINYL CLAD SHEETROCK2 FT X 4 FT CHARACTERS. 4 DR WIDTH SEE PLANS FOR FURTHER L,. / / SEE SCHEDULE,- INFORMATION. Arkinetics,Inc.and their Consultants shall be deemed the authors AC 23 CEILING GRID USG DX 15/161N., COLOR-WHITE MIN and owners of their respectivelnstrumentsofServiceandshall retain all common law,statutory and other reserved rights,including CEILING AC 25 ACOUSTICAL CEILING PANEL USG GLACIER't07, COLOR-SANDSTONE 0q0,-2 FT X_2 FT `- s ©,� • �t^iii copyrights.The Instruments of Service shall not be used for future N TILE/CARPET TO VCT „� CONT MTL RUNNER. TURN UP OR additions or alterations to this Project or for other projects,without CEILING GRID USG DX 15/161N., COLOR-SANDSTONE 010 QQ to �� DOWN 4" AT JAMBS AND the prior written agreement of Arkinetics,Inc.Any unauthorized use (AC-26) REDUCER of I2" FASTEN WITH SCREWS. of the Instruments of Service shall be at the Owner's sole risk and VG7/WDF BUTT JOINT � without liability to Arkinetics,Inc.and their Consultants -0 ( P-26 � PAINT - COORDINATE WITH WALL FINISHES �yN VGT/WDF CARPET/TILE 0:' • 3 • "�'' -- - kt l9 1 M►,1 SEALANT, TYP EA SIDE. arkinetics C 2016 CA P-30 PAINT - HVAC GRILLES/DIFFUSERS IN ALL 1 • • >,. .., . ,:• i, W it nr�_1 C f AG25/26 AREAS iuiu'nunu,im+nmw CONCRETE FLOOR VGT/WDF ■�■�■1 FIRE-RETARDANT TREATED _i • w____� ,;:, ., ,_ \ \ DRAWING TITLE: . D "`urns•"" -•--' WD OR MTL DR. RABBET SIZE TO BE x LOCKING. FINISH SCHUDULE • • • • I6 GA MTL DOOR FRAME, !0 CONCRETE SLAB '` r %. ' ' . LCONT MTL I15i(b" FOR 13/4" DR OR Igi(6" FOR 1%" DR. x d DOOR SCHEDULE CORNER BEAD. SEE PLANS AND SCHED FOR SWING F' _ 0 DIRECTION, DR SIZE AND TYPE. 3 DOUBLE ACTING DOOR. i FLOOR FINISH DETAIL FLOOR FINISH DETAIL w 16 GA MTL 3 PIECE KNOCK DOWN DR K X - 6" = 1'-0" VCT TO CARPET 6 = 1-0 FRAME WITH MIN 3 ADJUSTABLE , JAMS ANCHORS PER SIDE. SPOT GROUT. Cn • ®DOOR JAMB DETAIL �2 DOOR JAMB DETAIL SHEET#: 1-1/2" = 1'-0" 1)1-1/2" = 1'-0" i MECHANICAL SPECIFICATIONS A. GENERAL CONDITIONS OTHER CONTRACT DOCUMENTS N. DUCTWORK \� �GD I N PROA-�Ss> NOTE: NOTE: NOTE: � F O 1. The general conditions and other contract documents as set forth hereby are to be FAN, DUCT & CURB SHOWN MECHANICAL CONTRACTOR TO PROVIDE PITCH POCKETS FAN, DUCT & CURB SHOWN ct 1. Provide all sheet metal work as shown on the drawings in accordance with ARE FOR DIAGRAM PURPOSES ONLY. ::5: PE incorporated into and become a part of the specifications for the work under this division. OVER WALK-IN-FREEZER FOR ROOF MOUNTED ARE FOR DIAGRAM PURPOSES ONLY. the latest edition of the ASHRAE Guide and Data book, SMACNA Standards ACTUAL LENGTHS AND OFFSETS SHALL BE FIELD MEASURED EQUIPMENT - COORDINATE WITH EQUIP. SUPPLIER ACTUAL LENGTHS AND OFFSETS SHALL BE FIELD MEASUREDfi B. CODES AND PERMITS and this specification, the most demanding of which shall be the minimum standard. ROOFING WORK TO BE BY LANDLORD'S APPROVED ROOFING y� 0^ ; CONTRACTOR SUCH THAT WARRANTIES ARE NOT VOIDED. < 1. Comply with rules, regulations of state, county, and city authorities having jurisdiction over 2. Low Pressure Ductwork <i 14 Z' .C9 the premises, including safety requirements of OSHA. Do not construe this as relieving NOTE -94,1contractor from complying with specifications which exceed code requirements and not in NOTE: H. SN- AQP conflict therewith. a. All ductwork shall be consrtucted of galvanized steel except where noted on plans to be aluminum. Exposed ductwork in architecturally COORDINATE ROOF WORK WITH LANDLORD PRIOR TO FAN AND CURB EXPIRES:06/30/2016 2. Secure and pay for all permits and certificates of inspection required. Make payments to finished spaces shall be fabricated from "Paint Grip" galvanized steel INSTALLATION. MAINTAIN ALL PRE-EXISTING ROOF SUPPLIED AND INSTALLED BY MECHANICAL CONTRACTOR all public utilities for work performed by them in providing service connections. or similar mill surface etch treatment. WARRANTIES. SEAL C. LOCAL CONDITIONS b. Construct all ductwork following SMACNA "HVAC Duct Construction Standards," 1995 edition. f INLINE EXHAUST FAN 1. Visit site, become familiar with conditions affecting this work. No additional payment will LOUVER be made on claims that arise from lack of knowledge of existing conditions. c. All ducts, except kitchen exhaust, shall be constructed to 1" W.G. .g 2. This contractor shall be held to have examined the premises and site so as to compare d. Seal all ducts to seal Class "B." HOOD AND BACKIS PANEL SUPPLIED BY EQUIPMENT COMPANY, MECHANICAL them with the drawings and specifications. No allowance shall be made to the contractor (1) c } by reason of his failure to have made such examination or of any error on his part. 3. Special Service Ductwork HANGING HOODCONTRACTOR , EXHAURESPONSIBLEST DUCTINGFOR, CURB .N 2 .% 0 r� ALUMINUM EXHAUST DUCT FAN AND PLACING WALL PANEL C.) a� p oI� . - 3 D. DRAWINGS a. Kitchen Hood Exhaust - Concealed: Aluminum fabricated and - TO MEET LOCAL VENTILATION installed per local requirements or 16 gauge black steel, steel angle ill 1. Drawings and specifications are to be considered as supplementing each other. Work reinforcing, joints and seams welded watertight. Exposed: Aluminum REQMT'S.BY MECH CONT. ■ u- O cc\i, N 9 P PP 9 9 9 P = ON specified shall be performed or furnished as though mentioned in both specifications and fabricated and installed per local requirements or 18 gauge type 302 1'-4" SHROUD BY c � r.0 drawings. stainless steel, joints and seams welded, grind and polish to a No. 2 \ EQUIPMENT VENDOR. G.G. o � � c d- `r finish. FINISHED CEILING TO VERIFY DIMENSION OF 41) n `� 0 J N J 11 .- 2. The drawings are schematic only and are intended to show the approximate locations. Do �- �" FINISHING CEILING. TYPICAL not scale. 4.. Flexible Ducts UNISTRUT AND THREADED ROD FOR 10' CEILING HEIGHT. C + gi U AS REQUIRED fin`. :+✓ E. SHOP DRAWINGS a. Omniair Model 1300 Low pressure non insulated for exhaust ducts •■ ` C and supply air ducts in conditioned spaces up to 6" static pressure. simic o 114N 1. This contractor shall submit shop drawings on the items of equipment and systems as LIGHT - VAPOR PROOF '� necessary to clearly show equipment and construction. b. Install flexible tubing fully extended, free of sags and kinks. 1- HOOD ac is Maximum length of tubing shall be 5' 0". Flexible tubing shall be 48' _ BY EQUIP SUPPLIER o connected to supply air ducts with flared spin collar fitting. TYPE 2 LTJ N 'c 7 F. SUPERVISION EXHAUST CANOPY 7/ 60" / 0 I, E col,3 .1- 000 CONST. TO MEET c� 0. WIRING z a. o = °o 0 1. This contractor shall have in charge of the work, a competent superintendent with LOCAL,VENTILATION I - O O C" REQMT'S. SUPPLIED w PITCH HOOD BACKti) experience in the work to be installed under this contract. 1. All wiringincidental to this temperature control system shall beprovided by -a;c. `r P y BY EQUIPMENT SUPPLIER S.S. WALL PANEL TOWARDS DRAIN 181 _ �;m n the mechanical contractor. o 00 BY EQUIP SUPPLIER aI -al cs, co G. COORDINATION '= a) r� °� '- 2. The term "wiring" be construed to include furnishingof wire, conduit, -" I INSTALLED BY GC - ® U ayi N a'> N N 9 CONDENSATE DRIP U M U a Li: 1. This contractor shall coordinate his work and cooperate with the other contractors. He miscellaneous materials and labor as required for mounting and connecting 1 `� shall arrange his work with theirs so that there will be no delay in the proper installation. electrical control devices, and providing electrical interlocks between \ ` 2. Examine work of other trades which comes in contact with or is covered by this work. Do equipment. j - RE-HEAT EQUIPMENT not attach to, cover, or finish against any defective work, or install work of this division in P. EQUIPMENT r a manner which will prevent other trades from properly installing their work. Consult all drawings, specifications and details of other divisions of the work. 1. See schedule on drawing. FINISHED FLOOR PROJECT: H. CUTTING AND PATCHING - END OF SPECIFICATIONS n 1. All cutting and patching work related to this contract will be the responsibility of this Q contractor. I. GUARANTEE AND WARRANTIES RE-HEAT EQUIPMENTCC goodengineering GENERAL NOTES: COOKING LINE SIDE ELEVATION 0 w 1. Warrant that equipment and all work is installed in accordance with en ineerin / " COOKING LINE ELEVATION °C practice and that all equipment will meet requirements specified. Any equipment failing to I- Q perform or function as specified shall be replaced with complying equipment, without cost 1 1/2 = 1 -0 W D (Y to the owner. IC a N - - DUCTWORK AND DIFFUSERS m N 2. Guarantee against defects in workmanship and materials; make good repair or replace any cZ*kk‘, t--Izdefective work, material or equipment within one year from date of acceptance. 1. PROVIDE ALL LOW PRESSURE DUCTWORK SIZED EQUAL TO OR LESS THAN N g O oCJ. INSTALLATION REQUIREMENTS 0.1" W.G./100' (TYP.) UNLESS SCHEDULED OTHERWISE. INDICATE ALL DUCT SIZES ON SHOP DRAWINGS. z � � 1. Location of equipment, ducts, etc., on the drawings is diagrammatic; indicated positions 5 FEET MAXIMUM oma'SUPPORT END OF Q z Q shall be followed as closely as possible; exact locations shall be subject to building 2. PROVIDE MINIMUM DUCT RADIUS ON ELBOWS AT 1-1/2 TIMES DUCT SIZE. / 1 METAL DUCT I- = CSC construction and interferences with other work. Architect reserves right to make minor changes in location of any part of the work up to the time of roughing-in without 3. PROVIDE 5'-O" MAX. FLEX DUCT CONNECTION TO DIFFUSERS, TYPICAL. to 1171 V) ."4. - additional cost. "r N%.,,_ 1.-1Q ,._, 4. ALL CONCEALED SUPPLY DUCTWORK LOCATED IN NON-CONDITIONED SPACES - - VD BRANCH DUCT = f"' K. TEST AND ADJUSTMENTS SHALL BE INSULATED. (n 1. Obtain all inspections required by law, ordinances, rules, regulations of authorities having 5. ALL DUCTS SHALL BE FREE FROM CONTACT WITH ALL: PIPING, WALLS, ! MAIN SUPPLY AIR DUCTQ CD jurisdiction, furnish certificates of such inspections. Pay all fees and provide all equipment, ELECTRICAL CONDUITS, CEILING SUSPENSION SYSTEMS, ETC. power and labor necessary for inspections and test. - _ __ 6. PROVIDE THROAT WITH PROPORTIONAL SPLIT AND TURNING VANES ON TEE ___J\ / 2. Pressure testsFLEXIBLE DUCT '� TRANSITIONS. (BULLHEAD TEE'S WILL NOT BE PERMITTED. (USE AS REQUIRED p�, AIR I--I a. Test medium for refrigerant piping shall be oil pumped dry nitrogen. Twenty-four 7. CEILING DIFFUSER CORES AND BACK-PANS SHALL HAVE A FLAT BLACK FOR DIFFUSER ALIGNMENT) FLOW hour standing time minimum. Test the low side of the system to 150 psi and the ENAMEL FINISH. FACE TO BE OFF-WHITE BAKED ENAMEL ON PERFORATED high side to 300 psi. Tests shall conform to ANSI Standard B31.5 "Refrigeration PLATE AND MARGIN UNLESS SPECIFIED OTHERWISE BY ARCHITECT ANDi IL --- sk Piping." APPROVED BY MECHANICAL ENGINEER. NECK VELOCITIES NOT TO EXCEED 500 45' TAKE-OFF FPM MAXIMUM. PAINT DINING AND ---''- '"``~-- CEILING L. HVAC SYSTEMS ADJUSTMENTS AND BALANCE HALLWAY P-30 / \ NECK SIZE / GRILLE SIZE PROVIDE MANUAL BALANCING 8. PROVIDE GALVANIZED SHEET METAL DUCTWORK. ALUMINUM OR ALUMINUM / A 6 DAMPER WHERE SHOWN ON MARK: ISSUE: DATE: 1. Put all heating, ventilating, exhaust and air conditioning systems and equipment into full FLEX IS NOT PERMITTED. PLANS (SEE SPECIFICATIONS) PERMIT 02/23/16 operation and continue operation of same during each working day of testing and balancing. All testing and balancing shall be done under both summer and winter design 9. ALL PIPING AND DUCTWORK SHALL FREELY PASS THROUGH ALL WALLS AND DIFFUSER TYPE 100 1/4 WIDTH OF BRANCH DUCT conditions. FLOORS WITHOUT RIGID CONNECTIONS. PENETRATION POINTS SHALL BE AIR FLOW - CFM SLEEVED TO ALLOW PASSAGE OF PIPING OR DUCTWORK AND MAINTAIN 3/4" 2. Perform tests and balance systems in accordance with following requirements: TO 1-1/4" CLEARANCE AROUND THE OUTSIDE SURFACES. THIS CLEARANCE SHALL BE TIGHTLY PACKED WITH ONE POUND DENSITY GLASS FIBER, AND CEILING DIFFUSER BRANCH DUCTS W/ FL E CONNECTION LOW PRESSURE END OF SUPPLY AI R DUCT DETAIL a. Balance and adjust all air handling systems for design flow of supply, return, relief, CAULKED AIR TIGHT WITH NON-HARDENING SEALANT AFTER INSTALLATION OF NO SCALE N.T.S. exhaust and outside air to within 10% of design requirements. PIPING OR DUCTWORK. b. After or during one complete heating-cooling season, make any minor adjustments 10. PROVIDE FIRE DAMPERS WITH ACCESS IN ALL RATED WALLS IN ACCORDANCE that may be necessary to insure uniform temperatures throughout the space. WITH LOCAL CODES. M. INSULATION 11. FABRICATE, INSTALL, SEAL, AND INSULATE ALL DUCTWORK IN STRICT CONFORMANCE WITH THE REQUIREMENTS OF THE UNIFORM MECHANICAL CODE 1. All insulation shall be installed over clean dry surfaces. Insulation must be dry and in AND THE OHIO BUILDING CODE. good condition. Wet or damaged insulation will not be acceptable. No insulation shall be PREFERRED ALTERNATE ALTERNATE ALTERNATE applied prior to pressure test completion of the respective piping systems. 12. ALL EQUIPMENT, MATERIALS AND WORK SHALL CONFORM TO THE APPLICABLE TAKE-OFF DETAIL TAKE-OFF DETAIL TAKE-OFF DETAIL TAKE-OFF DETAIL CODES OF THE UNIFORM BUILDING, FIRE, MECHANICAL, AND ELECTRICAL 2. Fiberglass pipe insulation shall be installed with joints butted firmly together. Jacket laps CODES AS ADOPTED BY THE CITY AND ALL OTHER CODES, SAFETY ORDERS STANDARD 90' RECTANGULAR to be sealed with factory applied adhesive. Butt joints to be sealed with butt stripes, AND REGULATIONS AS ENFORCED BY THE STATE, AND CITY FIRE MARSHALL'Sr havingfactoryapplied adhesive. Valves and fittings shall be insulated usingmitered BELLMOUTH CONNECTION MINI-BELLMOUTH CONNECTION TO ROUND BOOT CONNECTION MAIN DUCT r " " " " " " r PROJECT#: i ~•_---t.'1 PP g PERTAINING TO THIS PROJECT. SIMILAR TO $UCKLEY SIMILAR TO BUCKLEY BUCKLEY MODEL 33000 AIR FLOW r sections of insulation, insulation cement, or premolded fitting insulation. The insulation MODEL BMD (SEAMLESS) MODEL MBMD (SEAMLESS) (CONTINUOUSLY WELDED) lir applied to the valves and fittings shall be covered with the same type of covering as used 13. PROTECTIVE BARRIERS SHALL BE INSTALLED IN FRONT OF EQUIPMENT WHERE �/ r DRAWN BY: �CHECKED BY: on the pipe insulation. EQUIPMENT IS SUBJECT TO MECHANICAL DAMAGE. \ / ` / `F\�// 6" L.(=)_ _♦ \ ��' MIN. Arkinetics,Inc.and their Consultants shall be deemed the authors - '- VANED ELBOWS TO BE and owners of their respective Instruments of Service and shall 3. Provide the following insulation products as manufactured by Owens-Corning. Insulation 14. SUITABLE OPENINGS WITH TIGHTLY FITTED COVERS SHALL BE PROVIDED TO VD k-T retain all common law,statutoryand other reserved rights,including products as manufactured by Armstrong, Certainteed or Knauf are acceptable. Adhesive MAKE FIRE DAMPERS ACCESSIBLE FOR INSPECTION. VD (ONLY WHEN OTHERS CONSTRUCTED AND INSTALLED copyrights.The Instruments of Service shall not be used for future N shall be Benjamin Foster or equal. DUCT SIZE HOLE SIZE AS DETAILED BY SMACNA additions or alterations to this Project or for other projects,without q DO NOT FIT) VD OC 15. CONDENSATE DRAIN LINES SHALL BE PROVIDED FOR ALL MECHANICAL (SEE PLANS) (SEE BELOW-TYP.) -.- • the prior writtenums of ment f Aretics,at Inc.wAny 's sole unauthorizeduse of the Instruments of Service shall be at the Owner's sole risk and 4. Owens Corning fiberglas 705: 1" thick asj equipment insulation (density 6 pcf) or EQUIPMENT WHICH PRODUCES CONDENSATE. without liability to Arkinetics,Inc.and their Consultants Armstrong ap armaflex sheet and roll insulation (3/4") `-o ..o .....c. OBD (ABOVE II arkinetics C 2016 to TANDARD 12" IN DEPTH) if Service RECTANGULAR 1 1 2 WIDTH RADIUS-TYPE ELBOWS ARE OPTIONAL; DRAWING TITLE: +7 .� - CONNECTION ( - / Mechanical Specifications > Exposed supply air ductwork (in non air conditioned spaces) SEE MECHANICAL SPECIFICATIONS) P 7 THIS DETAIL APPLIES TO SINGLE TAKEOFFS NOTE: and Details Exposed outside air intake ductwork TO DIFFUSER AS WELL AS BRANCH TAKEOFFS. ALTERNATE FITTINGS SHALL BE USED WHEN DUCT HEIGHTS DOES OIT ALSO APPLIES TO TAKEOFFS IN THE NOT PERMIT THE USE OF THE PREFERRED FULL SIZE BELLMOUTH X) 5. Owens Corning ed 150 frk 25: 2" thick faced ductwrap HORIZONTAL AS WELL AS VERTICAL DIRECTION. SUBMIT FITTINGS FOR REVIEW BY ENGINEER PRIOR TO INSTALLATION. m _ Service 7 Concealed supply air ductwork (except in return air plenums) DUCT TAKEOFFS LOW PRESSURE DUCT ELBOW DETAIL m Concealed outside air intake ductwork NO SCALE N.T.S. -1 6. Duct lining: Owens-Corning, 1" thick "Aeroflex Duct Liner" Type 300. Lining shall be SHEET#: w installed with stick-klips and adhesive per manufacturer's instructions. I, M - 1 0 1 0) 'V -n M1 . 103 MECHANICAL NOTES M1 . 102 LEGEND M1 . 104 EXHAUST FAN SCHEDULE OOFTO , \ T SC H ED J LE ,��,D PROF COOLING CAPACITY HEATING CAPACITY mac, G 4 N .6- �', TAG TONNAGE CFM OUTISIDE ESP SUPPLY FAN VOLTAGE MCA/MOCP � MANUFACTURER & MIN EER WEIGHT REMARKS O SYMBOL DESCRIPTION _ MARK (EF--#) EF-1 & 2 EF-3AIR B.H.P. TOTAL SENSIBLE MBH INPUT MBH OUTPUT MODEL NO. �' 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH SMACNA STANDARDS, SERVES RESTROOMS STEAM HOOD - --- ::58PE AND THE LOCAL BUILDING DEPARTMENT. _ SUPPLY DIFFUSER (PAINTED F-30 IN DINING - TRAIN 2. ALL DUCTWORK SHALL BE INSTALLED IN ACCORDANCE WITH THE AREA 4 HALLWAY) MANUFACTURER COOK COOK RTU-1 8.5 3400 800 0.5 1.25 208V/30 42.3/50 103 80.4 200 162 YHC102A3EHATRAIN 10.3 893 1-12 / .. AM E`a VI v G I`. LATEST SMACNA HANDBOOK. MODEL GC-142 100SQN-B -`` 1 ,LOQ O RETURN GRILL 24"x24" REMARKS: , 74 3. SUPPLY AND RETURN DUCTWORK SHALL BE GALVANIZED STEEL. , TYPE CLNG MTD INLINE, CEILING MOUNTED 1. MICROMETL CURB ADAPTOR -941 H SH -C P 4. SUPPLY DUCTWORK SHALL BE INSULATED DRIVE TYPE DIRECT DRIVE DIRECT DRIVE 2. FILTERS WITH FIBERGLASS INSULATION 1" THICK. EXHAUST DUCT 3. BELT DRIVE AIR FLOW (CFM) - 75 550 4. PROGRAMMABLE THERMOSTAT EXPIRES:06/30/2016 5. 'SPIN IN' TYPE FITTING SHALL BE INSTALLED IN THE DUCTWORK AS EXT. STATIC (IN.W.C) .5 .5 5. ECONOMIZER - DRYBULB WITH BAROMETRIC RELIEF ,+ INDICATED FOR CONNECTION TO DIFFUSERS IN THE FUTURE. A 6 IV 6. HAIL GUARD EC -A� 'CAL PLAN NOTES: SEAL DIFFUSER DESIGNATION AND CFM FAN SPEED RPM 1100 1361 7. DISCONNECT 6. PROVIDE ALL TEMPERATURE CONTROL WIRING AND EQUIPMENT. 100 ( ) FOR ALL HVAC EQUIPMENT. ELECTRICAL 120/1/60 120/1/60 8. NON-POWERED GFI OUTLET 9. HINGED ACCESS PANELS & EXTERNAL GAUGE PORTS / PRESSURE RESETS O NEW 8.5 TON ROOFTOP UNIT (RTU-1) ABOVE NEIGHBORING TENANT ON EXISTING CURB. TRANSITION 7. ALL SUPPLY AND RETURN DUCTWORK TO BE SEALED AT ALL JOINTS -H ROUND SPIN-IN WITH DAMPER SIZE 1/4 HP 1/4 HP 10. VERITCAL SUPPLY & RETURN FROM FULL SIZE OF UNIT SUPPLY AIR OPENING TO EXISTING 50/16 IN CURB ADAPTOR. TRANSITION TO PREVENT AIR LEAKAGE NOTES (1) (4) (5) (1) (2) (3) 11. ALL T-STATS PROVIDED WITH LOCKING COVERS FROM FULL SIZE OF UNIT RETURN AIR OPENING TO EXISTING 48/12 IN CURB ADAPTOR RETURN AIR 8. AFTER INSTALLATION THE SYSTEMS SHALL BE BALANCED BY AN 12. PROVIDE SMOKE DETECTOR W/TEST SWITCH (AUDIO/VISUAL) - RETURN AIR - FIELD INSTALLED DUCTWORK. SET UNIT OUTSIDE AIR QUANTITY AS LISTED ON ROOFTOP UNIT SCHEDULE. FANS TO RUN - /1/Ar- FLEXIBLE DUCT NOTES: CONTINUOUS DURING OCCUPIED HOURS. 6 a✓ INDEPENDENT TESTING AND BALANCING CONTRACTOR IN trOa� ACCORDANCE WITH AABC STANDARDS. (1) EXHAUST DISCHARGE TO BE LOCATED A MIN. OF 1O'-O" FROM ALL FRESH {�V/f�Jf92 i:ii o r� AIR INTAKES, VENTS, ETC. 2 MECHANICAL CONTRACTOR SHALL PROVIDE A SMOKE DETECTOR FACTORY MOUNTED IN UNIT OR MOUNTED 0O p . Lob- Cr OT THEp"10STAT CONTROL O IN RETURN AIR DUCT. SMOKE DETECTOR SHALL BE FURNISHED/INSTALLED BY MECHANICAL CONTRACTOR 0 THE DRAWINGS ARE PARTLY DIAGRAMMATIC AND ARE NOT INTENDED TO SHOW IN DETAIL (2) FAN TO HAVE ADJUSTABLE PULLEY SYSTEM FOR SPEED CONTROL. AND WIRED BY ELECTRICAL CONTRACTOR TO SHUT DOWN CORRESPONDING AIR CONDITIONING UNIT ■ Ci o LL _ n n ALL FEATURES OF THE WORK. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THESE (3) U.L. LISTED, SHALL HAVE PRE-WIRED DISCONNECT AND HINGED BASE FOR UNDER ALARM CONDITIONS. ALL WIRING SHALL BE IN CONDUIT PER N.E.C. SMOKE DETECTOR SHALL BE p c� O N N TS THERMOSTAT REMOTE SENSOR INSPECTION. c r c o 0 SPECIFICATIONS, DRAWINGS AND LOCAL GOVERNING CODES. A SYSTEM SENSOR MODEL DH100ACDCLP OR EQUAL. 01, E c� n- (4) FURNISH WITH GRAVITY BACKDRAFT DAMPER, CEILING GRILLE AND MODEL O o 0 0 THE EXTENT OF THE MECHANICAL WORK IS INDICATED ON THE DRAWINGS THE VXCAF ROOF VENT. O3 INSTALL AND WIRE NEW 7-DAY PROGRAMMABLE THERMOSTAT WITH LOCKING COVER. COORDINATE EXACT a. 0 J N J 0- LL MECHANICAL DRAWINGS ARE SCHEMATIC AND SHOW THE RELATIONSHIP BETWEEN ® REMOTE TEST STATION FOR DUCT DETECTOR (5) RESTROOM EXHAUST FAN CONNECTED TO WALL SWITCH. LOCATION WITH ARCHITECT AND OWNER PRIOR TO ROUGH-IN. PROVIDE CONTROL WIRING AS REQUIRED. + °��' U. EQUIPMENT AND CONNECTIONS. NOT ALL RISERS AND DROPS ARE SHOWN. DO NOT w U SCALE THE DRAWINGS FOR EXACT SIZE OR LOCATIONS. DUCT SIZE ARE NET INSIDE 04 MECHANICAL CONTRACTOR TO MOUNT SMOKE DETECTOR REMOTE KEY STATUS AND TEST STATIONS (WITH 0 DIMENSIONS. ie CONNECT TO EXISTING AUDIO AND VISUAL ALARM) NEXT TO UNIT THERMOSTAT. M.C. TO INDICATE DETECTOR SERVING ROOFTOP so I _ VERIFY EXACT LOCATION FOR EXHAUST HOOD BASED ON EQUIPMENT PLACEMENT DO NOT MECHANICAL VENTILATION UNIT. COORDINATE EXACT LOCATION WITH FIRE MARSHAL PRIOR TO ROUGH-IN. ALL WIRING SHALL BE BY .C7) L ELECTRICAL CONTRACTOR IN CONDUIT PER N.E.C. REMOTE STATION SHALL BE A SYSTEM SENSOR MODEL E. CCI SCALE DRAWINGS. OA REQUIRMENTS SSK451 OR EQUAL. o ei--, FIRE DAMPER REQUIRED �' _ MECHANICAL CONTRACTOR TO MAINTAIN REQUIRED CLEARANCES TO COMBUSTIBLES FROM ROOM NAME ROOM AREA PEOPLE CFM PER SQ. CFM PER OUTSIDE AIR Q ROUTE 8"0 EXHAUST DUCT UP TO EXTERIOR WALL WITH 8" WALL CAP. MAINTAIN A MINIMUM OF 10'-0" d _ THE KITCHEN HOOD AND EXHAUST DUCTWORK AS PER THE DRAWINGS AND CURRENT F. PERSON FROM ALL FRESH AIR INTAKES. 0p o 0 !?,. MECHANICAL CODE. O 4 SMOKE DUCT DETECTOR -- ° _ N. DINING AREA 833 59 0.18 7.5 593 oaco PROVIDE CLEAR ACCESS TO ALL EQUIPMENT. O TYPE II HOOD HALLWAY 33 0 0.06 0 2 • `� DUCT SHALL BE 8/8, ALUMINUM OR STANDARD GAUGE TYPE 302 STAINLESS STEEL FABRICATED . a WATERTIGHT, EXPOSED JOINTS AND SEAMS TO BE SEALED. HOOD PROVIDED BY TENANT & INSTALLED BY �' SUPPLY DUCTING SHALL BE FABRICATED SHEET METAL AND BE DESIGNED AND M 1 . 105 HOOD SCHEDULE SERVING AREA 273 5 0.18 7.5 87 # - N N CONSTRUCTED IN ACCORDANCE WITH THE LATEST ASHRAE AND SMACNA STANDARDS. KITCHEN 421 5 0.18 7.5 114 G.C. SEE DETAILS ON SHEET #M-101 FOR ADDITIONAL INFORMATION. 111 ■ Q - c-• - MECHANICAL CONTRACTOR TO COORDINATE WITH STEEL TRUSS MANUFACTURE ON SEINES PITCO RETHERM UNITS REQUIRED OUTSIDE AIR 7960 8/8 EXHAUST DUCT UP TO EXHAUST FAN "EF-3". SEE DETAIL ON SHEET #M-101 FOR ADDITIONAL LOCATION AND PLACEMENT OF ROOFTOP EQUIPMENT, MECHANICAL CONTRACTOR IS INFORMATION. RESPONSIBLE FOR ALL INCURRED CHARGES FOR MATERIAL AND FABRICATION AS SIZE 42"x54"x15" REQUIRED. MATERIAL STAINLESS STEEL 0 PAINT DIFFUSERS/RETURN GRILLES IN DINING ROOM & HALLWAY TO MATCH CEILING COLOR M 1 . 10 6 AIR BALANCE SCHEDULE (RUST-OLEUM: FOSSIL - SATIN FINISH). TYPE TYPE II, STEAM HOOD PROJECT: O 22/22 RETURN AIR DUCT DOWN TO RETURN AIR GRILLE. LISTINGS U.L. 710 NOTE: DUCTWORK DUCTWORK: ALUMINUM OR STAINLESS MARK RTU-1 EF-1,2 EF-3 MECHANICAL CONTRACTOR RESPONSIBLE FOR PROVIDING AIR STEEL, FABRICATED & INSTALLED PER SUPPLY AIR FLOW (CFM) 3400 1 a 12/12 RETURN AIR DUCT DOWN TO RETURN AIR GRILLE. - Q BALANCE REPORT PER LOCAL CODE. LOCAL REQUIREMENTS BY MECHANICAL OSA REQUIRED 800** 0 PROVIDE LOUVER FOR HOOD EXHAUST WITH 0.61 FT2 FREE AREA. o CONTRACTOR EXHAUST FAN 550 CFM (SEE FAN SCHEDULE) % OSA 22% 12 CONNECT NEW 26/16 SUPPLY DUCT TO EXISTING 50/16 SUPPLY MAIN. 0 w RETURN AIR FLOW (CFM) 2680 13 0 Q EXHAUST AIR FLOW (CFM) 75 550 0 CONNECT NEW 28/16 RETURN DUCT TO EXISTING 48/12 RETURN MAIN. HELD VERIFY ALL CONDITIONS NOTE: QUANTITIES 1 2 1 14 CAP EXISTING BRANCH DUCTWORK. CC 0 N NO PVC OR COMBUSTIBLE MATERIALS ALLOWED IN PLENUM < N • DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL AIR CEILING SPACE. TOTAL PRESSURIZATIONS 800 -150 -550 15 REMOVE EXISTING TRANE MODEL #SPCC-B756-A. RETAIN ROOF CURB. PROVIDE AND INSTALL MICROMETL m VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO CURB ADAPTOR INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL RESULTING BUILDING PRESSURIZATION (CFM) 100 ZIli Nj Q� z INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD o F- MODIFICATIONS DUE TO EXISTING CONDITIONS. x t z IG O w o o z o • THE OWNER PRRORTOR SHALL TO BIDDING CONTACT INTERPRETATIONSTAND ENGINEER OR p p n n I u DUCTWORK \Q o ~ _ 0 BRANCH I a i 0' LA CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL ; -_ - _- V) Q I. 1-1 i I z COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BYEI I EF-1 EF-2THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE GFM S . -.--- C6 = FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. -10 6"0 i50 (..4• BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OFLOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR e�i w I JBIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT . ..... ....... .... .. . ..........................................'.- .. 01--258 O OO ACCORDANCE WITH GOVERNING CODES, THE PLANS AND r-- 400 LSPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITET, ENGNEER OR OWNER OF ANY APPARENT 251-400 1O"� IIJDISCREPANCIES BEEN GOVERNING CODES AND DESIGN INTENT. L co C 6 401-650 12"0 1 50 I I 8"0 MAIO ri ran 50 , M O MARK: ISSUE: DATE: M1 . 107 REGISTER AND DIFFUSER SCHEDULE I111 i PERMIT 02/23/16 o O SIZE / EF-3 MARK - - - MARK TYPE MANUFACTURER MODEL NECK FACE '' 1 in FRAME TYPE MATERIAL A �,� ,�7 , 1 A 10 Q 1275J DIFFUSER (1) TITUS TMS SQUARE SKTA-40 SEE PLAN 24"X24" LAY-IN STEEL \ A30100 A DIFFUSER `� 1 1 (PAINTED P-30 IN DINING AREAS) 0/1111‘1A M/1/� Sao 400 L J t RETURN GRILLE (1) TITUS 50F EGGCRATE RAPA SEE PLAN SEE PLAN LAY-IN ALUM. A 10 - -- I " 8" B RETURN = 400 - - - J c ,DIFFUSER (1) TITUS TMS SQUARE SKTA-40 SEE PLAN 12"X12" SURFACE STEEL I ' I IP. w d� -- DIFFUSER � f I co J I �p ITOW L 1I C. I _II lc0 ` L N , 1 I i `,, J O A 10 , Mark° •3 ,x A 6 325 , 2. 100 - a r NI B /40PROJECT #: _._...-... B 440 A 10 - ' - 250 r DRAWN BY: CHECKED BY: - r ............. - I 1 ' I J ,' Arkinetics,Inc.and their Consultants shall be deemed the authors 410 ! 1 1 \\ 124/14 %... and owners of their respective Instruments of Service and shall N r I I retain all common law,statutory and other reserved rights,including c - I r - __ opynghts.The Instruments of Service shall not be used for future -- -- --- - - --- - additions or alterations to this Project or for other projects,without N 0 - • ••• • the prior written agreement of Arkinetics,Inc.Any unauthorized use C i to \ of the Instruments of Service shall be at the Owner's sole risk and without liability to Arkinetics,Inc.and their Consultants N / arkinetics Ccs 2016 1 Lu „ ® / DRAWING TITLE: Gil y Mechanical Plan and a Schedules 00 xi RTU-1 0 -1 m ® 4 1 MECHANICAL PLAN I� 1/4" = 1'-0" �� 4111. m H SHEET If: m - 1 02 0) co PLUMBING NOTES NOTES: " • HOT OR COLD WATER SUPPLY 1. ALL WATER AND WASTE PIPING SHALL BE CONCEALED IN THE WALLS 0O PROF PLUMBING SPECIFICATIONS IIF HORIZONTAL BRANCH IS LESS THAN 20' ' CODES,ALL UTHENLOCAG L HEALTHK DEPARTMENT AND STRICTBE DONE IN ACCORDANCE LOCAL LABUILD NG TDEPARTMENT. RESTROOM NOTES: PLUMBING LEGEND ,�� `� N F Ess, A. GENERAL CONDITIONS OTHER CONTRACT DOCUMENTS INSTALL PER PDI LONG, PROVIDE ONE WHA AT END OF LINE 2. THE PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR THE COST OF <0 F� C) PDI I I STANDARDS AND IF BRANCH IS GREATER THAN 20' LONG, CUTTING AND PATCHING ROOFS, CONC. FLOOR NECESSARY TO ACCOMMODATE 1. INSTALL PIPE INSULATION AT ALL EXPOSED HOT WATER AND DRAIN PIPING SYMBOL DESCRIPTION /::6: PE 1. The general conditions and other contract documents as set forth hereby are to be incorporated SIZE MANUFACTURER'S PROVIDE ANOTHER WHA IN MIDDLE, EACH THE PLUMBING WORK. TOILET ROOMS. into and become a part of the specifications for the work under this division. "A" INSTRUCTIONS SIZED FOR HALF THE FIXTURE UNITS 3. THE PLUMBING CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS TO THE - i. t•, B. CODES AND PERMITS ., ., I FOOD SERVICE EQUIPMENT. SEE FOOD SERVICE EQUIPMENT PLANS FOR THE 2. THE OPERATING PARTS OF ANY DISPENSING FIXTURE SHALL BE WITHIN 48" - - EXISTING PIPING TO REMAIN OR NEW AND BY OTHERS 7 -, / i ,4 i. Comply with rules, regulations of state, county, and city authorities having jurisdiction over o 0 0 0 o - ECONNECTIONS.XACT LOCATIONS OF ALL NEW EQUIPMENT AND THE NECESSARY PLUMBING MAX. OF FINISHED FLOOR. _ 2. 4. ALL PLUMBING PIPING SHALL BE CONCEALED WHEREVER POSSIBLE UNLESS 3. EACH TOILET ROOM SHALL HAVE HANDICAP STALLNOTEDASH.C.-HANDICAP GSAN GREASE SANITARY 4/ Q. N 4 Sx,...291"- the 4 the premises, including safety requirements of OSHA. Do not construe this as relieving SINGLE FIXTURE MULTIPLE FIXTURES H.C. H NDICAP contractor from complying with specifications which exceed code requirements and not in conflict NOTED ON THE DRAWINGS OTHERWISE. DOMESTIC WATER PIPING IS SHOWN STALL SHALL BE 5'-O"x5'-O" MIN. AND SHALL MEET ALL LOCAL/STATE SAN SANITARY EXPIRES:06/30/2016 therewith. FIXTURE UNIT TABULATION ABOVE THE CEILING WITH DROPS IN WALLS AND PARTITIONS. THE CONTRACTOR CODES AND COMPLY WITH FEDERAL A.D.A. REQUIREMENTS. PDI PIPE FIXTURE MAY ELECT TO INSTALL THE PIPING BELOW THE FLOOR. ALL PIPING BELOW -V VENT 2. Secure andfor allpermits and certificates of inspection required. Makepayments to all SIZE SIZE UNIT LOAD FIXTURE COLD HOT pay l e4 THE FLOOR SHALL BE TYPE 'K' SOFT COPPER WITH NO JOINTS BELOW THE 4. SIGNAGE DESIGNATING "MEN" AND "WOMEN" REST ROOMS LETTERS SHALL BE public utilities for work performed by them in providing service connections. A 1/2" 1-11 VALVE WATER CLOSET 10 -- FLOOR. 2" HIGH RAISED 1/32" UPPERCASE SANS SERIF AND SHALL BE CW DOMESTIC COLD WATER SEAL 5. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY NEW FITTINGS, VALVES AND ACCOMPANIED WITH GRADE 2 BRAILLE. MOUNT SIGNAGE 48" A.F.F. TO G. LOCAL CONDITIONS B 3 4" 12-32 TANK WATER CLOSET 5 -- OFFSETS ETC. WHEN INSTALLING OR REPLACING PLUMBING FIXTURES. HW DOMESTIC HOT WATER / CENTERLINE OF SIGN AND MAX. $„ FROM DOOR JAMB ON WALL ADJACENT 1. Visit site, become familiar with conditions affecting this work. No additional payment will be " CONTRACTOR MAY REUSE EXISTING PIPE VALVES AND FITTINGS. TO LATCH SIE OF DOOR. FINISH SHALL BE WITH WHITE CHARACTERS ON made on claims that arise from lack of knowledge of existing conditions. C 1 33-60 LAVATORY/SINK 1.5 1.5 6. MATERIALS: BLACK BACKGROUND. 1W INDIRECT WASTE 2. This contractor shall be held to have examined the premises and site so as to compare them D 1-1/4" 61-113 JANITOR'S SINK 3 3 a. UNDERGROUND WATER PIPING: TYPE "K" SOFT COPPER 5. ALL HAND SINKS SHALL HAVE HOT AND COLD MIXING DEVICE ID INDIRECT DRAIN with the drawings and specifications. No allowance shall be made to the contractor by reasonb. ABOVEGROUND WATER PIPING: TYPE "L" HARD COPPER j c of his failure to have made such examination or of any error on his part. E 1-1/2 1 14-154 c. SOLDER 95-5 TIN-ANTIMONY OR SILFOS. (DO NOT USE LEAD BEARING CD - CONDENSATE DRAIN e I �' a°�i N o ` o SOLDER). PLUMBING FIXTURESoM 0 o D. DRAWINGS F 2" 154-330 12" X 12" FLOOR SINK 0 .' c- d. SANITARY AND WASTE PIPING: KITCHEN WASTE PIPING SHALL BE 'NO PLUMBING FIXTURES SHALL BE AS MANUFACTURED BY AMERICAN STANDARD, = c v HUB' CAST IRON OR SCH 40 PVC. ALL OTHER SANITARY AND WASTE BRIGGS, CRANE, ELKAY, FIAT, JUST, KOHLER, MANSFIELD, MUSTEE OR EQUAL. ■ = d 1. Drawings and specifications are to be considered as supplementing each other. Work specified PC TO PROVIDE WATER HAMMER ARRESTERS BY SIOUX CHIEF, PRECISIONFLOOR DRAIN "- 0 c N shall be performed or furnished as though mentioned in both specifications and drawings. PLUMBING PRODUCTS, WATTS OR APPROVED EQUIVALENT WITH PISTON PIPING SHALL BE EITHER 'NO HUB' CAST IRON OR SCHEDULE 40 PVC. O',H. o 0 e. VENT PIPING: 'NO HUB' CAST IRON, SCHEDULE 40 GALVANIZED STEEL WATER CLOSET - WC PHYSICAL HANDICAPPED c c,� .c AND 0-RING CONSTRUCTION, HAVING PDI #WH-201, ASSE #1010 AND "HIGHLINE" D4 SHUTOFF VALVE o E c'lT c� 3 FLOOR MOUNTED, KOHLER K-3427, VITREOUS CHINA, ELONGATED 2. The drawings are schematic only and are intended to show the approximate locations. Do not ANSI #A112.26.1 M CERTIFICATION, INSTALL IN HORIZONTAL OR VERTICAL OR DWV-PVC. VERIFY LOCAL CODES O 0 0 0 scale. f. FREEZER CONDENSATE PIPING: HEAT TRACED CONDENSATE DRAIN PIPING BOWL, CLOSE-COUPLED TANK, BOLT CAPS, LUSTRA K-4650, OPEN FRONT SEAT, U _i cv 0_ u: POSITION, BUT NEVER UPSIDE DOWN. INSTALL IN LINE WITH WATER {�I CHECK VALVE WHITE LESS COVER. 1.6 GALLON FLUSH. a� E. SHOP DRAWINGS FLOW DIRECTION IF POSSIBLE. SIZE THE UNITS AS SHOWN ON THE SHALL BE TYPE 'L' COPPER WRAPPED WITH RAYCHEM SELF REGULATING c U DRAWINGS AND/OR PER THE TABLES SHOWN ABOVE. HEAT TAPE AND PIPE INSULATION TEMPERATURE/PRESSURE RELIEF VALVE C l� }r / g. BEVERAGE CONDUIT PIPING: SCHEDULE 40 PVC PIPE WITH LONG RADIUS WALL MOUNTED LAVATORY - LAV PHYSICAL HANDICAPPED w 1. This contractor shall submit shop drawings on the items of equipment and systems as necessary ELBOWS. KOHLER "GREENWICH" K-2023, VITREOUS CHINA, 20" X 18" FOR CONCEALED UNION o to clearly show equipment and construction. h. GAS PIPING: SCHEDULE 40 BLACK STEEL ASTM A-53 WITH WROUGHT ARMS, 4" CENTERS, "CORALAIS" K-15597 SINGLE LEVER FAUCET AND K-7715 CD -2 F. SUPERVISION WATER HAMMER ARRESTORS IRON FITTINGS. GRID DRAIN. SMITH 700 SERIES CARRIER. THERMOSTATIC MIXING VALVE. INSULATE PIPING UP OR DOWN immtcLS i. FLOOR DRAINS; NEW FLOOR DRAINS SHALL BE AS MANUFACTURED BY EXPOSED HOT AND COLD WATER AND DRAIN PIPING WITH CLOSED CELL TUBING o SMITH OR ZURN. ALL FLOOR DRAINS TO HAVE TRAP PRIMERS AS INSULATION KIT TRUBO OR EQUAL. 0 0 ._ 1. This contractor shall have in charge of the work, a competent superintendent with experience in PIPING UP ;;-- the work to be installed under this contract. NOT TO SCALE REQUIRED BY LOCAL CODES. m � d o 0 MOP SINK - MS: ca > 0 ca 0 0 „ " FLOOR CLEANOUT o = cO co G. COORDINATION FIAT MODEL MSB-2424, 24"L X 24"W X 10"D, DRAIN BODY FACTORY INSTALLED p 0 ai STAINLESS STEEL #302 WITH COMBINATION DOME STRAINER AND LINT BASKET. II WALL CLEANOUT a d 1. This contractor shall coordinate his work and cooperate with the other contractors. He shall NOTE: PVC PIPING SHALL NOT BE USED IN RETURN AIR PLENUMS. DRAIN BODY SHALL PROVIDE FOR A LEAD CAULKED JOINT TO A 3" I.P.S. FAUCET: 0 / al a_ al • arrange his work with theirs so that there will be no delay in the proper installation. SPEAKMAN MODEL SC-5811-RCD, ROUGH CHROME PLATED CAST BRASS WITH > REDUCER += ai ir, m 11- VACUUM BREAKER, INTEGRAL STOPS, VANDAL-RESISTANT FOUR ARM HANDLES WITH E® N N N 2. Examine work of other trades which comes in contact with or is covered by this work. Do not COLOR-CODED INDEXES, CAST BRASS NOZZLE WITH 3/4" HOSE COUPLING BALANCING VALVE ¢ U,c,“..) a Li.: attach to, cover, or finish against any defective work, or install work of this division in a DISCHARGE, PAIL HOOK AND TOP BRACE. ADJUSTABLE THREADED BRASS WALL manner which will prevent other trades from properly installing their work. Consult all drawings, LANDLORD NOTES DCV DOUBLE CHECK VALVE specifications and details of other divisions of the work. FLANGES. 8" CENTERS WITH ±1/8 ADJUSTMENT. H. CUTTING AND PATCHING NO PVC OR PEX ABOVE GRADE. URINAL - UR TMV THERMOSTATIC MIXING VALVE PLUMBING IS NOT PERMITTED IN LANDLORDS DEMISING WALLS. FURR OUT WALLS WALL MOUNTED, ADA COMPLIANT, KOHLER "BARDON" K-72524-NA, VITREOUS AFF ABOVE FINISHED FLOOR 1. All cutting and patching work related to this contract will be the responsibility of this contractor. WHERE NECESSARY. CHINA, K-13519-CP FLUSHOMETER, 0.5 GALLON FLUSH. PROJECT: I. GUARANTEE AND WARRANTIES ALL TOILET ROOMS TO HAVE FLOOR DRAINS WITH TRAP PRIMERS. RETHERM NOTES: GC GENERAL CONTRACTOR 1. Warrant that equipment and all work is installed in accordance with good engineering practice " " PC PLUMBING CONTRACTOR < and that all equipment will meet requirements specified. Any equipment failing to perform or TGC TO COORDINATE ALL FLOOR CUTS AND CONNECTIONS TO LL WATER AND 1. THE RETHERM UNIT MUST HAVE A CAST IRON FLOOR SINK AND NO HUB Q function as specified shall be replaced with complying equipment, without cost to the owner. SANITARY MAINS WITH MALL OPERATIONS PRIOR TO BID THIS TENANT IS TO VERIFY CAST IRON PIPING, CONTINUOUS TO SANITARY LINE MC MECHANICAL CONTRACTOR0 ALL SANITARY, GREASE WASTE, WATER MAIN AND GAS CONNECTION POINTS, FOR 2. PROVIDE 3/4" HW TO REAR OF UNIT 8" A.F.F. (C LOCATION, SIZE, INVERT DEPTHS AND CAPACITY. COORDINATE ALL CONNECTIONS WITH 3. PROVIDE 1" GAS LINE TO RIGHT SIDE OF HOOD LINE 2. Guarantee against defects in workmanship and materials; make good repair or replace any MALL OPERATIONS. EC ELECTRICAL CONTRACTOR 0 w defective work, material or equipment within one year from date of acceptance. 4. PLUMBING CONTRACTOR TO PROVIDE 1/2" FLEX WATER LINE C ' - J. INSTALLA110N REQUIREMENTS VERIFY APPROVAL FROM MALL TO RECESS THE GREASE INTERCEPTOR. MALL MAYI- Q REQUIRE A SURFACE ON THE FLOOR INTERCEPTOR. w D m 1. Location of piping, equipment, etc., on the drawings is diagrammatic; indicated positions shall be CC N _ followed as closely as possible; exact locations shall be subject to building construction and VERIFY IN FILED ALL LANDLORD PLUMBING WORK, SIZES AND LOCATIONS. m < v) interferences with other work. Architect reserves right to make minor changes in location of any 1" e1 a part of the work up to the time of roughing-in without additional cost. PROVIDEAELASTOMERIC INSULATION LINE OVER r ii \--,A, (V z Cal HEAT TRACING ON CONDENSATE LINE IN �$ (/1 FREEZER BOX ONLY. (ALSO PROVIDE THE ,W1) z ` K. TEST AND ADJUSTMENTS ELECTRIC HEAT TRACING.) /-- AIR INTAKE (SIONTROL FITTING) p[ 1. Obtain all inspections required by law, ordinances, rules, regulations of authorities having DRILL HOLE IN SIDE OF BOX _ g O z jurisdiction, furnish certificates of such inspections. Pay all fees and provide all equipment, AND PROVIDE GROMMET OR 2" VENT 1 2" VENT \ O t,_, ,...., SLEEVE WITH SILICONE SEAL 1" DX COIL -`� power and labor necessary for inspections and test. CO `A t- ce 0 = Q AROUND PIPE PENETRATION 2. Pressure tests TO MAKE IT WATERTIGHT. CO INSTALL DRAIN TO POP CARBONATOR Z Q LINE BEHIND �--I a. Al! piping shall be given the following pressure test without appreciable pressure drop. PROVIDE TRAP PROVIDE CLEANOUT LD SHELVING IN PVC DRAIN LINE FOUNTAIN I (- WALK-IN BOX. FROM DISH AND OUTLET to Equipment which would be damaged by the required test pressure shall be isolated from AT BOTTOM OF IN TURNS AND ENDS o c Q PREP SINKS -�► .�.����y �� the system during testing. RISER FLAT OF PIPE. COORDINATE. AIR GAP BETWEEN INLET -�=�" AGAINST WALL. COPPER OR PVC TOP OF FLOOR SINK AND SERVICE MEDIUM (PSI) HRS. DISCHARGE INTO MAKE CONNECTION TO CONDENSATE DRAIN LINE DRAIN DISCHARGE CARBONATOR SFS WITH AIR COIL AS REQUIRED. INDIRECT ,L P P FROM EQUIPMENT CW IN DRAIN oo g v a ) Z -D4- CV .0 r-1 Domestic Water water 125 6 GAP OF TWICE ANCHOR RISER TO BOX EXTERIOR WALL „� Gas Piping air 50 24 PIPE DIAMETER, FLOOR /--'- G MINIMUM 2". _ b. Sanitary sewers per state plumbing code and local authority. - COOLER OR FREEZER BOX. �e VERIFY LOCAL CODES BYPASS FLOOR T�}r \WAU< IN 1TO ICE MAKER ' ' A FOR BACKFLOW DEVICE •A^ .. .A �. . A ` FLOOR L '� FLOOR SINK-----... b o GREASE REQUIRED ON CW INLET 1. Pipe & fittings t" SEE FLOOR PLAN FOR RECEPTACLE LOCATION. INTERCEPTOR TERMINATE FLOW CONTROL AIR- -3" SAN TO FLOOR SINK TO FLOOR SINK Fire Protection - per NFPA 13 standards INSTALL PIPE HIGH AS POSSIBLE, ANCHORED TO WALL OF BOX WITH SUPPORTS INTAKE ABOVE FLOOD RIM LEVEL OF BUILDING DRAIN DRAIN BACKWASH HOSE Domestic Water - type "L" hard copper AT MAXIMUM SIX FOOT CENTERS. USE TYPE "M" HARD COPPER TUBE AND SINK FROM FLOW CONTROL FITTING. j 3" t MARK: ISSUE: DATE: Waste & Drain piping (above ground interior) - no-hub cast iron or PVC. FITTINGS WITH LEAD-FREE SOLDER JOINTS. SLOPE HORIZONTAL PIPE AT PERMIT - 02/23/16 Building Sewers & Drains (underground) - sanitary sewers to 5'0" outside building walls shall be MINIMUM TWO PERCENT. PROVIDE CHROMATONE PAINT ON PIPE EXTERIOR TO service weight cast iron, Bell & Spigot, soil pipe with Tyler "Ty-Seal" neoprene pipe gaskets or BOX. REFER TO "INDIRECT DRAIN" DETAIL FOR OTHER REQUIREMENTS. TRAP PVC. PVC is not to be used in return air plenums. WALK IN BO CONDENSATE DRAIN INTERIOR GREASE INTERCEPTOR DETAIL FLOOR SINK FS HD DRAIN DETAIL WATER FILTER DIAGRAM Refrigerant - Type "L" hard copper. M. VALVES NOT TO SCALE NO NOT TO SCALE NOT TO SCALE 1. Valves in water piping: Ball valves with screwed ends, min. 150 lbs., Swp. Valves used far shut-off and balancing shall be equipped with memory stop. N. INSULATION -'`'` NATURAL GAS PIPING RECOMMENDED SUPPORT SPACING ROOF PIPE SUPPORT A5 MANUFACTURED BY MIRO 1. All insulation shall be installed over clean dry surfaces. Insulation must be dry and in good i FOR BLACK STEEL PIPE INDUSTRIES,"PILLOW BLOCK"PIPE STAND. MODEL3 - " • = FLOOR condition. Wet or damaged insulation will not be acceptable. No insulation shall be applied #3-R STAND WILL ACCOMODATE PIPE UP TO 3 IN prior to pressure test completion of the respective piping systems. PIPE SIZE DISTANCE BET}1EEN DIAMETER: MODEL#`I-RAH,ROLLER TYPE,FOR TRAP PRIMERS AS • (IN) SUPPORTS(FT) SIZES TO 4". MODEL 46-RAH FOR PIPES UP TO 6" FLOOR SINK 3 REQUIRED BY LOCAL 2. Fiberglass pipe insulation shall be installed with joints butted firmly together. Jacket laps to be VACUUM BREAKER DIAMETER FOR INFO; I-SOO-168-6818. DRAIN CODES sealed with factoryapplied adhesive. Butt to be sealed with butt stripes, havingfactoryPER CODE REQ•D ) PP jointsP 1/2 6 3" applied adhesive. Valves and fittings shall be insulated using mitered sections of insulation, CONCENTRIC VENT THRU ROOF 3/4- I 8 PATE PIPE SEAL, \......." insulation cement, or remolded fitting The insulation applied to the valves and AMTROL EXPANSION TANK 1-1/4 TO 2-1/2 10 P insulation. PP BY PLUMBING CONTRACTOR WITH ALUM, BASE PROJECT#: I i,_J�, _ l fittings shall be covered with the same type of covering as used on the pipe insulation. 0 171[ ___w/ DIAPHRAGM 8" DIA 3 d LARGER 12 WITH 5" FLANGE TRAP x 14" LONG 3. Provide the following insulation products as manufactured by Owens-Coming. Insulation products I 1" HW FLOOR DRAIN DETAIL DRAWN BY: CHECKED BY: as manufactured by Armstrong, Certainteed or Knauf are acceptable. Adhesive shall be Benjamin ASME PRESSURE PIPE CLAMP,CONNECT TO STAINLESS Foster or equal. & TEMPERATURE " SUPPORT WITH I/2" x 10 STEEL CLAMP PATE PVC STEPPED NO gO,gl„E Arkinetics,Inc.and their Consultants shall be deemed the authors RELIEF VALVE 1 CW STAINLESS STEEL SCREWS, PVC BOOT and owners of their respective Instruments of Service and shall 4. Material - OVERSIZE CLAMP TO ALLOW retain all common law,statutory and other reserved rights,including PATE PIPE SEAL, copyrights.The Instruments of Service shall not be used for future N - f PIPE TO EXPAND AND CONTRACT. additions or alterations to this Project or for other projects,without O Domestic hot water - 1/2" thick ASJ/SSL fiberglass 3/4" GAS WITH ALUM. BASE the prior written agreement of Arkinetics,Inc.Any unauthorized use C " FG G---2 WITH 5" FLANGE of the Instruments of Service shall be at the Owner's sole risk and 13 Domestic cold water - 1/2" thick ASJ/SSL fiberglass -I without liability to Arkinetics,Inc.and their Consultants Iv WATER GA5 PIPE,PAINT WITH TWO COATS F.; 0. WASTE SSS HEATER G of RUST INHIBITING PAINT. DECK MEMBRANE /BASE FLASHING ar inetics®20 6 ■ _� 1. Run all drains e i in as direct as possible. Actual location of drains and waste piping shall 1" DIELECTRIC UNION TVP. NYLON FRICTION ABSORBING y DRAWING TITLE: 9 piping Pa PP9 ( ) G) meet the various building conditions. Do any work necessary to conceal piping or clear piping 3/4" -•� ROLLER. - D of other trades. DRAIN PIPE ;., PLUG COCK �J"", �i Plumbing Specifications ,„ P. WATER SUPPLY SYSTEMS TO S S G 1" BALL VALVE (TVP.) - PROVIDE EXTRA LAYER OF AWA MASTIC �I W W W O ROOFING MATERIAL BELOW PIPE DECK INSULATION A SUPPORT. _a 1. Extend water service from valved water connection provided with hot and cold water being c-p III--G I PIPE m supplied and connected to all fixtures and equipment. , ROOF DECK K Q. GAS PIPING SYSTEMS = F.F.L. Cn 1. Extend new gas piping from the meter located at the exterior wall, Connect to all rooftop HVAC -- I m units, kitchen equipment & water heaters. Install drip leg and shutoff valve at connection. SHEET#: Ce END OF SECTION GAS FIRED WATER PIPING DIAGRAM ROOF PIPE SUPPORT DETAIL PIPE ROOF PENETRATION DETAIL TYPICAL / NO SCALE j NOT TO SCALE NOT TO SCALE 0) P. 1 01 8 PLUMBING PLAN NOTES: EPROF O CONNECT NEW SANITARY TO EXISTING 4" MAIN IN THIS AREA. PLUMBING CONTRACTOR SHALL GAS LOAD SUMMARY I- (-----0-- �� + N FSSVERIFY EXACT LOCATION, SIZE, AND INVERT OF EXISTING SANITARY MAIN. SAWCUT AND TRENCH FF �O FLOOR AS REQUIRED AND PATCH FLOOR TO MATCH EXISTING. EQUIPMENT CFH \ 1) S. OCONNECT TO EXISTING WATER METER AND 1-1/2" COLD WATER LINE. VERIFY EXACT LOCATION WATER HEATER 120 � / e OF EXISTING MAIN IN FIELD AND COORDINATE EXACT REQUIREMENTS WITH LANDLORD'S PROJECT • VAT RY I �_ --- 2" '.i• d ��MANAGER. RETHERMALIZER 165 3„I CSL\ 7 '; C 20 O HVAC ROOFTOP UNIT 1 200 i 7 4 2- 33 CONNECT TO LANDLORD PROVIDED 2" LOW PRESSURE GAS LINE. EXTEND 1" LINE AND Fp I .. ''/l9 CONNECT TO WATER HEATER, NEW ROOFTOP UNIT, AND RETHERMALIZER. SIZE PIPING PER 1 > H. SHePP SCHEDULE AND PROVIDE GAS PRESSURE REGULATORS AT EACH EQUIPMENT. TOTAL 485 ti 1 / EXPIRES:06/3012016 ftl O EXTEND 1" GAS LINE TO ROOFTOP UNITS AND PROVIDE SHUTOFF VALVE, UNION, REGULATOR 4„ 9 / I AND DIRTLEG. / 3,s SEAL O5 WATER HEATER (GAS), 1" CW & HW, 1" GAS LINE AS REQUIRED. 2 „ WATER HEATER: A.O. SMITH BTH-120, 120,000 BTU/H, 60 GALLONS, COMPLETE WITH VENT KIT SP4 ,// 2 �6 BY PLUMBER. I`-.., 4" 3" / A FP OPITCO RETHERMALIZER 3/4" CW & HW CONNECTION W/ BACK FLOW PREVENTOR & GATE I N. PROVIDE A CAST IRON FLOOR SINK / VALVE; INDIRECT WASTE TO FLOOR SINK, 1" GAS CONNECTION 55,000 EA 165,000 BTU/H ---.4:„:"---..... AND A MINIMUM OF 1 O'-0" RUN OF <;‹/ CAST IRON PIPING FOR HOT WATER TOTAL, 12X12 IRON FLOOR SINK, 3" CAST IRON WASTE, 10'-0" RUN OF CAST IRON /I ` ti TEMPERING OF REfHERMALIZER. / aa) N o r..- PIPING FOR CASTM WATER +160'F. PROVIDE DRAIN TEMPERING VALVE (DTV) AS REQUIRED �, / } o o BY CODE. CONNECT 3/4" HW TO RETHERMALIZER AND 3/4" CW TO DTV. SEE MECHANICAL / 0 _c r o SHEETS FOR GAS PIPING. / 1,-, \ \ 3" G O 4" //// VAT R ■ -_ �� F5 o _ co Co FIELD VERIFY ALL CONDITIONS i - / O o N N Oj GREASE INTERCEPTOR, ASHLAND POLY TRAP 4850 5OGPM - 100LB CAPACITY 3" INLET W/ - -- 2„ c c N 0 0 FLOW CONTROL 1-1/2" VENT UP. FIELD VERIFY EXACT PLACEMENT OF GREASE TRAP AND • DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL \ FS P� ,/ o E -- — -- . COORDINATE WITH FOOD SERVICE EQUIPMENT VENDOR AND ZOUP TO AVOID LEG CONFLICTS. VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO 1 P� �' / G) O J QN J k.. PROVIDE ALL APPURTENANCES FOR A COMPLETE INSTALLATION INCLUDING FLOW CONTROL AND INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL 3 `' 3 // + a' AIR VENT. INSTALLATION SHALL BE IN STRICT ACCORDANCE WITH CITY REGULATIONS. PROVIDE INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD I \ 3„ i/ C 0 aa-_) U SPECIAL HD DIAMOND PLATE COVER OVER-LAYS WHEN INSTALLED IN PEDESTRIAN TRAFFIC MODIFICATIONS DUE TO EXISTING CONDITIONS. I �ti 4" // , AREAS. P.C. TO ENSURE A MINIMUM OF 2% SLOPE FOR SANITARY FROM FLOOR SINK TO I 3" / ■ `� N GREASE TRAP SUCH THAT GREASE TRAP INLET IS LOWER THAN THE FLOOR SINK OUTLET. • THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR 1 \ // p o INSTALL GREASE TRAP EXTENSION IF NECESSARY TO ALLOW FOR SLOPE FROM FLOOR SINK. OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND / F CD .E - P.C. TO ENSURE A MAXIMUM OF 50 GPM FLOW RATE FROM 3-COMPARTMENT SINK INTO CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL 11 _ 3'j 3" o4=9o (� FLOOR SINK AND INSTALL A SECONDARY FLOW CONTROL DEVICE PRIOR TO FLOOR SINK IF COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY 0 1-1/2" T\ 0. cP- ►` // L rn THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE / o NECESSARY. r FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. ! r = // FS 0 D 2 8 ts ' 0 0 O8 3-COMPARTMENT SINK, 3/4" HW & CW 2" INDIRECT WASTE FROM SANITIZING, RINSE, WASH & ° _ co �"' I` T BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF I "15'4- LOCAL cc O SOLIDS STRAINER TO FLOOR SINK, 3" DIRECT CONNECTION TO GREASE INTERCEPTOR. INSTALLED 2" /''� ` ti w O - rn LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR I / _ 7 a a c BY G.C.; 3/4" CW & HW FOR SPRAY RINSE ABOVE SOLIDS STRAINER. BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT VENT TO ROOF THROUGH EXISTING / 1" ■ . ACCORDANCE WITH GOVERNING CODES, THE PLANS AND FLUE. FIELD VERIFY EXACT LOCATION. �I I , �I? I( ,/ 2" 3" m a� m o Og 1/2" CW THROUGH FILTER TO ICE MAKER +60"A.F.F W/ DCV & GATE VALVE, (2) 3/4" SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL I I 3 / I 1 4" \ N COPPER DRAINS TO FLOOR SINK. SEE WATER FILTER DIAGRAM ON SHEET P-101. ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT J ,/ I -.... El ¢ U co U EL IL OFREEZER DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. s' / 1 p 3" / 3/4" COPPER DRAIN FROM BLOWER COIL TO FLOOR DRAIN WRAPPED WITH ELEC. HEAT TAPE - / BY REF. INSTALLER, FINAL CONNECTIONS BY G.C. ,.// .�� 2 -7 i ` ti / T 11 HAND SINK, 1/2" HW & CW 1 1/2" W & V-UP W/ TMV SET TO 110'F. I✓ GR sE 1c2>. PROJECT: 12 PREP SINK 3/4" HW & CW 2" INDIRECT WASTE W/ TMV SET TO 110'F. 0 CI j 13 1/2" CW FROM FILTER FOR CARBONATOR +60" A.F.F W/ DCV & GV - BY PLUMBING Q CONTRACTOR. SEE WATER FILTER DIAGRAM ON SHEET P-101. SANITARY ISOMETRIC DIAGRAM O ICC 14 12"x12" FLOOR SINK. REFER TO A1.02 FOR DIMENSIONAL LOCATION. NO SCALE 0 w 15 FLOOR MOUNTED SERVICE SINK, 3/4" HW & CW 3" W, 1 1/2" VENT UP. 0 T&S - MOP HANGER B-0653 BY PLUMBER I- Q Lu D m 16 WATER CLOSET, 1/2" CW, 4" WASTE, 2" VENT. WATER CLOSET HAND OPERATED FLUSH Q cy N CONTROL SHALL BE MOUNTED ON OPEN SIDE OF TOILET AREA. M kk) N � z 6� 1 Z LAVATORY, 1/2" HW & CW, 1-1/2" WASTE, 1-1/2" VENT, WITH TMV SET TO 110'F. Z111114 # � �18 3" FLOOR DRAIN. PROVIDE TRAP PRIMER. REFER TO A1.02 FOR DIMENSIONAL LOCATION. 4 W z 0019 PROVIDE AN ASSE 1022 APPROVED BACKFLOW PREVENTER FOR ANY POTABLE WATER 0 0 z 0 CONNECTIONS TO BEVERAGE DISPENSING EQUIPMENT. \piz - W.C.O. 3/4" 0 20 PLUMBING CONTRACTOR TO VERIFY WATER QUALITY AND HARDNESS TO DETERMINE IF WATER 11 I I -1-+I -- I• 1 9 II-, =I-1-f' (y ? I �} I I J _ _`._ ^ SAN _ _ _ I z SOFTENER WILL BE REQUIRED AND PROVIDE A BID ALTERNATE FOR PROVIDING AND INSTALLING _JrL - J I l _r I.I ♦ l.. _11 IL I IS I 7:11 _:-T)� IT i� f "'-CW— I WC I- A COMPLETE WATER SOFTENER SYSTEM IN THE EVENT A WATER SOFTENER IS REQUIRED. IIS -I 41 } -, y 13 I ,x - _{ , T HW FD - _ II L.. .__..Al I r #- Yl f EY} !� I * Illi! ! — LAV 7EvEA,F,N0GRATmoTRD.• �j .k:42 i3L - h1 .d 1 1L�I ki � •_=+ -- . _ ` V/ WCQ7 0 ' CALCIUM CARBONATE LEVELS IN WATER � !ILII �� � � ' � _''_, �'T I-� _.�. I C/7 - 0 TO 60 mg/L: (SOFTENER NOT REQUIRED) 4 •_ -- ......_. -_ __., I cn = �j - 61 TO 120 mg/L: (MODERATELY HARD, SOFTENER RECOMMENDED) I�` !-J! = ISI I I CO 0 - 121 TO 180 mg/L: (HARD, SOFTENER REQUIRED) I (1 a D - MORE THAN 180 mg/L: (VERY HARD, SOFTENER REQUIRED) !I! I Vl I ,,I I 1 L-i-11 _ + O INSTALL FOR DIMENFLOORSIONAL SINKFLUSHWITH FLOOR AND WITH A 10' CAST IRON RUN. REFER TO i[- I IY I— - !I r T I- --_ _1 �. .... .F ...- __._.. _� ,. ..7_, i i iii' I A1.0221 � = 1 __ _IL 1111 7 I k I u- 1 1 --•i'-- 1 I I I I I 1 I 1=u =, lm Q 41111 I I I I I v) � .�I rr^ ��� I I i I I II r 1 e, I - - ` = I I II II I I� I t-" I _--0 1 0 ,'-1 t! -=---1L_ - iI - I - I - _iI- _ [. _*7%_]..„ O 3/4" I III. �•il -- - --:.-_ -- i k� - . . „.. ,2L2_- of ISSUE: DATE: LAV Mil, I ©0 MARK - - �-.. r -1 SAN -. PERMIT 02/23/16 • ® FS 1 SAN FD .. III .. C.O. w I ■ v [4 - - _ _ c f- - - = = n i::.. I I ® 3/4” cl CW i _ I c � HW - 1-1/2" \ I mm J /4 A '�I! i' I _ _ _ ______ __ it_ L — —t-- . I � I III1 .r -FS- �,' MI ' II T'I j1 u ff ! 'IIS0 {Y I ti I 4 C 0 FS • 1110v Ii Vf — IA I ,,-I_I: i F -- II�, -�I 11 - I -GAS GAS LL GAS GAS 1" 0 IIS II I liii I LTA I 1 3/1" �� „ C.O. p SAN SAN L ---SAN—\- -CW SAN\— p u O 1_1/2-- 1 SAN �ii 1-1/2- ---- -1/2 — SAN— CO, .10L:4_1--11 ___ —CW CO 12411 = CW I I C� CW -T Q PROJECT# I- III II I I 11 �'; �1 I HW "1.: HW I ID HW Q Fo U Ik J` II 1 'Ir_ 3/4„ ! 1„- ( FDI DRAWN BY: CHECKED BY: FSw ' II TI I II ♦• Ill I ��� � ❑�I SINK SINK J 01--- V V i Arkinetics,Inc.and their Consultants shall be deemed the authors I `;i " i I II Il `-JL-��u❑❑ =ID 1-1/4" , D and owners of their respective Instruments of Service and shall L.1±1--ii —. -- 3 II_ � I` retain all common law,statutory and other reserved rights,including N —I • —�ice• i I ) I ._.. ....-.__ .,.. ❑ l V u I C M S ® {� copyrights ns or The Instruments of Serviceosf shall not be used for futureut — - - R FS 33 �7 O _ V V V V V additions alterationstothis Project for other projects,without 0 ❑ •• `... the prior written agreement of Arkinetics,Inc.Any unauthorized use ' — — ' - ® ©a of the Instruments of Service shall be at the Owner's sole risk and OQ without liability to Arkinetics,Inc.and their Consultants arkinetics 0 2016 Ci) POP LINE RUN OVERHEAD. COORDINATE EXACT ROUTING Q WITH OTHER TRADES. INSTALL. PER MANUFACTURER'S C7 DRAWING TITLE: D RECOMMENDATIONS. VERIFY EXACT REQUIREMENTS WITH Plumbing Plan xi SODA MACHINE SUPPLIER/INSTALLER AND PROVIDE CHASE O FOR SODA LINE AS REQUIRED PER CODE. VERIFY IF O CHASE IS REQUIRED WITH INSTALLER. X 'T7 m O U W PLUMBING PLAN SHEET#: 1/4" = 1'-4" Eri L p_ 102 0 SECTION ELECTRICAL GENERAL PROVISIONS CIRCUIT BREAKER PANEL SCHEDULE GENERAL ELECTRICAL NOTES ���O PRO,_ . 1. THE PROVISIONS OF THE INSTRUCTION TO BIDDERS, GENERAL CONDITIONS, SUPPLEMENTARY 10. ALL COVER PLATES SHALL BE STAINLESS STEEL WITH BEVELED EDGES AND SMOTH SATIN �� G I N S� CONDITIONS, ALTERNATES, ADDENDA, AND DIVISION 1 ARE A PART OF THIS SPECIFICATION. FINISH. BOTH THE WIRING DEVICES AND THE COVER PLATES SHALL BE BY THE SAME Name: A Voltage: 208/120V-30-4W Buss: 200 AMP KAIC: C�� F O • A REQUIREMENT OCCURRING IN ONE IS AS BINDING AS THOUGH OCCURRING IN ALL. THEY MANUFACTURER. Back Hallway200/3 1. THE ROUTING OF ALL SURFACE MOUNTED/EXPOSED CONDUIT IN FINISHED AREAS (OR WHERE NOTED �� 1 _-�' ARE INTENDED TO BE COMPLEMENTARY AND TO DESCRIBE AND PROVIDE FOR A COMPLETE Mounting: Recessed Location: MCB: KWD: 24.1 ON THE DRAWINGS) SHALL BE COORDINATED AND APPROVED BY THE ARCHITECT PRIOR TO :.:5= PE WORK. CONTRACTORS AND SUB-CONTRACTORS SHALL EXAMINE SAME AS WELL AS OTHER 11. ALL OPENINGS IN FIRE RATED FLOORS, SHAFTS, AND WALLS ACCOMMODATING PENETRATING CKT DESCRIPTION LTG REC FSEQ HVAC MISC GB PH GB MISC HVAC FSEQ REC LTG DESCRIPTION CKT INSTALLATION. EXPOSED RACEWAYS SHALL BE RUN PARALLEL WITH OR AT RIGHT ANGLES TO WALLS. •DIVISIONS OF THE SPECIFICATIONS WHICH AFFECT WORK UNDER THIS DIVISION. ITEMS SUCH AS CABLES, CONDUITS, RACEWAYS, CABLE TRAYS, OR BUSWAYS SHALL BE 1 KITCHEN LIGHTING 0 58 20/1 A 20/1 0.28 NIGHT/EWER. LIGHTING 2 s' C. - FIRE STOPPED. THE INSTALLATION OF FIRE STOPPING MATERIALS SHALL CONFORM TO THE 2. CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF ALL MECHANICAL. PLUMBING AND 1 ,, '' G 2. MATERIAL OR LABOR WHICH IS NOT INDICATED ON THE DRAWINGS OR SPECIFICATION BUT LATEST FIRE RESISTANCE DIRECTORY AS PUBLISHED BY U.L. ALL RACEWAYS PASSING FROM 3 SOUP TRACK LIGHTS 0.21 20/1 B 20/1 0.36 - DUCT DETECTORS 4 REFRIGERATION EQUIPMENT AND ALL OTHER EQUIPMENT REQUIRING ELECTRICAL CONNECTION PRIOR .< y� o INTERIOR TO THE EXTERIOR OF THE BUILDING SHALL BE FILLED WITH AN APPROVED 5 DINING TRACK LIGHTS 0.21 20/1 C 20/1 0 36 P.0 OUTLET(I.G.j 6 TO THE COMMENCMENT OF WORK. �i 1 q Q� WHICH IS OBVIOUSLY NECESSARY TO COMPLETE THE WORK (AND IS USUALLY INCLUDED IN 'q/!•7 QP H SN� SIMILAR WORK) SHALL BE PROVIDED. DRAWINGS AND SPECIFICATIONS ARE TO BE MATERIAL TO PREVENT THE CIRCULATION OF WARM AIR TO THE COLDER SECTION OF THE 7 DINING DOWNLIGHTS 0 34 20/1 A 20/1 0.54 GEN REC KITCHEN 8 3. DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT OF SYSTEMS AND WORK CONSIDERED AS SUPPLEMENTING EACH OTHER. WORK SPECIFIED BUT NOT INDICATED, OR RACEWAY. NEC 300.7(A). - INCLUDED. FOLLOW DRAWINGS IN LAYING OUT WORK AND CHECK DRAWINGS OR OTHER TRADES EXPIRES: 06/30/2016 9 BATHROOM LIGHTS o 28 20/1 B 20/1 0.48 GEN REC DINING 10 RELATING TO WORK TO VERIFY SPACE IN WHICH WORK WILL BE INSTALLED. MAINTAIN ALL CODE INDICATED BUT NOT SPECIFIED, SHALL BE PROVIDED AS THOUGH MENTIONED IN BOTH SPECIFICATIONS AND DRAWINGS. 12. THE ROUTING OF ALL SURFACE MOUNTED/EXPOSED CONDUIT IN FINISHED AREAS (OR 11 SERVING DOWNLIGHTS 0.19 20/1 C 20/1 1.16 GENERAL REC. (I.G.) 12 REQUIRED HEADROOM AND SPACE CONDITIONS AT ALL TIMES. WHERE NOTED ON THE DRAWINGS) SHALL BE COORDINATED AND APPROVED BY THE 13 FRONT SEATING LOTS 0-07 20/1 A 20/1 0 18 EXTERIOR SIGNAGE 14 4. THE ELECTRICAL CONTRACTOR SHALL DERIVE THE EXACT LOCATION OF ALL DEVICES, SWITCHES, SEAL 3. IN THE EVENT OF DISCREPANCIES BETWEEN THE CONTRACT DOCUMENTS (DRAWINGS AND ARCHITECT PRIOR TO INSTALLATION. EXPOSED RACEWAYS SHALL BE RUN PARALLEL WITH OR 15 SPARE 20/1 B 20/1 SPARE 16 EQUIPMENT, ETC, WITH ARCHITECTURAL ELEVATIONS AND FINISHES. LIGHTING FIXTURES, CEILING SPECIFICATIONS), THE CONTRACTOR SHALL ADHERE TO THE MORE STRINGENT REQUIREMENT. AT RIGHT ANGLES TO WALLS. 17 ROOF RECEPTACLES 0.36 20/1 C 20/1 SPARE 18 MOUNTED EQUIPMENT, ETC. SHALL BE COORDINATED WITH ARCHITECTURAL CEILING PLANS. 4. VISIT THE SITE OF THE WORK AND BECOME FAMILIAR WITH CONDITIONS AFFECTING THE SECTION GROUNDING AND BONDING 19 MENUBOARD RECEPT. 0.36 20/1 A 20/1 SPARE 20 5. SUPPORT PANELBOARDS, JUNCTION AND PULL BOXES INDEPENDENTLY TO BUILDING STRUCTURE WITH INSTALLATION. SUBMISSION OF A PROPOSAL SHALL PRESUPPOSE KNOWLEDGE OF SUCH 21 MENUBOARDRECEPT. 0.36 20/1 B 20/1 SPARE 22 NO WEIGHT BEARING ON RACEWAYS. CONDITIONS AND NO ADDITIONAL COMPENSATION SHALL BE ALLOWED WHERE EXTRA LABOR 1. GROUND ALL CONDUITS, CABINETS, MOTORS, PANELS, FIXTURES, AND OTHER EXPOSED 23 MENUBOARD RECEPT. 0.36 20/1 C 20/1 SPARE 24 6. ALL FEEDERS AND BRANCH CIRCUITS SHALL CONTAIN AN INSULATED EQUIPMENT GROUND OR MATERIALS ARE REQUIRED BECAUSE OF IGNORANCE OF THESE CONDITIONS. NON-CURRENT CARRYING METAL PARTS OF ELECTRICAL EQUIPMENT IN ACCORDANCE WITH ALL PROVISIONS OF THE NATIONAL ELECTRIC CODE AND LOCAL CODES. 25 DISPLAY RECEPTACLE 0.36 20/1 A 20/1 SPARE 26 CONDUCTOR. EQUIPMENT GROUNDING CONDUCTOR SHALL BE INSTALLED THE ENTIRE LENGTH OF ALL BRANCH CIRCUIT RUNS AND SHALL BE BONDED TO EACH BOX AND DEVICE IN THE CIRCUIT, 41) ° 'ED 5. DEFINITIONS 27 BATHROOM RECEIPT. 0.72 20/1 B 20/1 SPARE 28 7 O 2. GROUNDING OF THE ELECTRICAL SYSTEM SHALL BE BY MEANS OF AN INSULATED 29 OFFICE RECEPTACLE 0.72 20/1 C 20/1 SPARE 30 7. LIGHTING, POWER, TELEPHONE AND COMMUNICATIONS OUTLETS SHALL NOT BE PLACED BACK TO o= __ o 0 A. "CONTRACTOR" AS USED WITHIN THE ELECTRICAL SPECIFICATIONS SHALL REFER TO THE GROUNDING CONDUCTOR INSTALLED WITH CIRCUIT CONDUCTORS IN ALL CONDUITS. E 5 m _c co uU BACK. GROUNDING CONDUCTORS SHALL BE SIZED IN ACCORDANCE WITH N.E.C. 250.122 AND 31 SPARE 20/1 A 20/1 SPARE 32 • -0 2 = _ ( a3 ELECTRICAL CONTRACTOR. r Ll O N N SHALL RUN FROM GROUNDING BUS OF SERVING PANEL TO GROUND BUS OF SERVED 33 SPACE B 20/1 SPARE 34 8. ALL CONDUIT PENETRATIONS THROUGH FIRE RATED WALLS AND FLOORS SHALL BE PROTECTED BY ,LQ O N PANEL, GROUNDING TERMINAL OF RECEPTACLES, LIGHTING FIXTURE HOUSINGS, GROUNDING MATERIALS TESTED IN ACCORDANCE WITH UL1479/ASTM E-814. INSTALLATION SHALL FOLLOW d .c T.:'= B. "EQUAL" OR "EQUIVALENT" SHALL BE UNDERSTOOD TO MEAN OF THE SAME QUANTITY, 35 SPACE C 20/1 SPARE 36 TERMINAL OF LIGHT SWITCHES OR METAL ENCLOSURES OF SERVED EQUIPMENT. MANUFACTURER'S INSTRUCTIONS AND MAINTAIN THE FIRE RATING OF WALLS AND/OR FLOORS o c� c� � � SIZE, NUMBER, VALUE, DEGREE, INTENSITY AND THE ITEMS ARE SIMILAR IN ALL 0 n -> 0 o 0 0 RESPECTS. THE ENGINEER WILL MAKE THE FINAL DECISION OF ACCEPTANCE OF 37 SPACE A 5.08 38 AFFECTED. PROVIDE HILTI C5240 FIRESTOP SEALANT, CSFM LISTING NO. 4060-1200:100, OR W 3. INSTALL BONDING JUMPERS ACROSS ALL BUILDINGS, EXPANSION JOINTS, AND ACROSS 39 SPACE B 50/3 5.08 EXISTING HVAC UNIT 40 EQUIVALENT STATE FIRE MARSHAL APPROVED AND LISTED MATERIAL. + J N J IL THESE ITEMS. CONDUIT EXPANSION FITTINGS. .RTU-1' CaI U 41 SPACE C 5.08 42 9. ALL FLUORESCENT LIGHTING FIXTURES SHALL BE SUPPORTED AT EACH CORNER WITH FOUR (4) #12 0 C. "CONTRACT DOCUMENTS" SHALL BE UNDERSTOOD TO ENCOMPASS DRAWINGS AND r} UTILIZE THE EXISTING BUILDING DISTRIBUTION GROUNDING CONDUCTOR CURRENTLY SERVING TOTALS (KW) 1.87 3.24 0.00 0.00 0.00 PH 0.36 15.23 000 2.72 0.28 TOTALS (KW) AWG GALVANIZED STEEL WIRES AND SECURED TO THE BUILDING STRUCTURE IN ACCORDANCE WITH �, SPECIFICATIONS FOR ARCHITECTURAL, STRUCTURAL, CIVIL, MECHANICAL, ELECTRICAL AND N.E.C. REQUIREMENTS. A PHYSICAL MEANS SHALL ALSO BE PROVIDED TO PREVENT THE ACCIDENTAL 6 o ..1_1- THE EXISTING PANEL AS INDICATED ON THE DRAWINGS. ALL OTHER PERTINENT DISCIPLINES. DISENGAGEMENT OF THE FIXTURE FROM THE CEILING SUPPORT OR 'T-BAR". LOAD SUMMARY PANEL DATA TOTAL LTG REC FSEQI-NAC MISC 10. ALL ELECTRICAL EQUIPMENT AND MATERIAL SHALL BE SUITABLE FOR INSTALLATION AND USE IN CF5 D. "PROVIDE" SHALL BE INTERPRETED TO MEAN THE CONTRACTOR SHALL FURNISH ALL a, 0, SECTION POWER DISTRIBUTION E UIPMENT KWC DF KWD X 125% KVV Phase A: 7.8 1.3 1 4 0.0 5.1 0.0 CONFORMITY WITH THE PROVISIONS OF NEC 110.3(A)(1). o LABOR, MATERIALS, EQUIPMENT AND SUPPLIES INCLUDING TESTS AND INSPECTIONS - NECESSARY TO INSTALL, CONNECT, APPLY, ERECT, CONSTRUCT, AND PLACE IN LTG 2.1 1.25 2.7 KW Phase B: 7.5 0.5 1 6 0.0 5.1 Q4 U cn 0 0 1. PROVIDE BRANCH CIRCUIT BREAKER PANELBOARDS EQUIPPED WITH CIRCUIT BREAKERS OF , .- • - 11. BRANCH CIRCUIT WIRING MUST BE COLOR CODED PER NEC 210.5. c� OPERATING CONDITION. REC 6.0 NEC 6.0 KW Phase C: 8.4 0.4 3.0 0.0 5.1 0.0 o = THE FRAME AND TRIP RATING AS SPECIFIED HEREIN AND AS SHOWN ON THE CONTRACT O O h E. "FURNISH" SHALL BE INTERPRETED TO MEAN THE CONTRACTOR SHALL SUPPLY AND DRAWINGS. PANELBOARD BUS STRUCTURE AND MAIN LUG/MAIN CIRCUIT BREAKER SHALL FSEQ 0.0 0.65 0.0 ELECTRICAL SYMBOL LEGEND HAVE THE CURRENT RATING AS SHOWN ON THE CONTRACT DRAWINGS. BUS BAR Miii 0 6 ti DELIVER TO THE JOB SITE SPECIFIED MATERIAL, EQUIPMENT, AND SUPPLIES. HVAC 15.2 1.00 15.2 �, c� 1 5 0 CONNECTIONS SHALL ACCEPT BOLT-ON CIRCUIT BREAKERS. PANELBOARDS SHALL BE DEAD FRONT SAFETY TYPE. BUS BARS SHALL HAVE ANTI-TURN SOLDERLESS LUG CONNECTIONS MISC 0.4 0_70 0.3 E > Co a'O� N N F. "INSTALL" SHALL BE INTERPRETED TO MEAN ASSEMBLING, PLACING, ERECTING, WIRING FOR ATTACHING FEEDERS. WHERE MULTI-POLE CIRCUIT BREAKERS ARE REQUIRED, THEY TOTAL 23.7 24.1 30.2 INDICATES 1-POLE CIRCUIT BREAKER #1 IN PANEL "A". CIRCUITS TO PANEL "B" WILL ■ ■ 2 U CO U AND TO MAKE FULLY OPERATIONAL. SHALL BE COMMON TRIP. ALL PANELBOARDS SHALL BE LOCKABLE AND KEYED ALIKE. AMPS 65.8A 67.OA 83.7A #1 HAVE A DESIGNATION "B" NEXT TO CIRCUIT NUMBER PANEL BOXES SHALL BE AT LEAST 20 INCHES WIDE. CIRCUIT BREAKERS SHALL BE 6. INCLUDE ALL LABOR, MATERIAL, EQUIPMENT, TOOLS, TRANSPORTATION, INSURANCE, THERMAL MAGNETIC, MOLDED CASE BOLT-ON TYPE. INDICATES 2-POLE CIRCUIT BREAKER #3,5 IN PANEL "A". CIRCUITS TO PANEL "B" WILL TEMPORARY PROTECTION, SUPERVISION, SERVICES FOR THE PROPER COMPLETION OF ALL A/#2'4 HAVE A DESIGNATION "B" NEXT TO CIRCUIT NUMBER ELECTRICAL WORK. ITEMS OMITTED, BUT NECESSARY TO MAKE THE ELECTRICAL SYSTEM A. PANELBOARD AS A COMPLETE UNIT SHALL HAVE A MINIMUM SHORT CIRCUIT RATING OF �1 NI PM COMPLETE AND WORKABLE, SHALL BE UNDERSTOOD TO FORM PART OF THE WORK. 208(240)/120 - 10,000 AIC, UNLESS OTHERWISE NOTED A/#6,8,10 INDICATES 3-POLE CIRCUIT BREAKER #7,9,11 IN PANEL "A". CIRCUITS TO PANEL "B" 01 CERTIFICATESAFOR ALL PPROVAL ERMITS AND OWNER.INSPECTIONS REQUIRED AND TURN OVER ALL CIRCUIT BREAKER PANEL SCHEDULE WILL HAVE A DESIGNATION "B" NEXT TO CIRCUIT NUMBER PROJECT: B. PANELBOARDS SHALL BE MANUFACTURED BY SQUARE D, SIEMENS, GENERAL ELECTRIC, CONDUIT STUB OUT, CAP, MARK, AND RECORD. OR EATON/CUTLER-HAMMER. Name: B Voltage: 208/120V-30-4W Buss: 200 AMP KAIC: 7. TEMPERATURE CONTROLS ARE PROVIDED AND WIRED BY A CONTROLS CONTRACTOR UNDER Back HallwayMLO KWD: 22.5 CONDUIT CONTINUATION. 0 DIVISION 15. Mounting: Recessed Location: MCB: -� Q C. A GLAZED DIRECTORY FRAME SHALL BE PROVIDED INSIDE THE DOOR AND SHALL BE CKT DESCRIPTION LTG REC 'FSEO HVAC MISC C/B PH C/B MISC HVAC FSEQ REC LTG DESCRIPTION CKT 8. WORK SHALL BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE PROVISIONS OF LOCAL OF SUFFICIENT SIZE TO GIVE DESCRIPTION OF EACH CIRCUIT. TYPED DIRECTORY CARDS 1 O SHALL BE PROVIDED LISTING EACH CIRCUIT SERVED. 1 .POS MONITORS (I.G) '1' 0.72 20/1 A 1.35 2 $ 3 -- THREE WAY p[ AND STATE CODES AS WELL AS THE NATIONAL ELECTRICAL CODE (NEC), AS INTERPRETED 20/2 HOT HOLDING TABLE'5' - S1,S2,etc. - DENOTES CONTROL OF LIGHT FIXTURES WITH CORRESPONDING DESIGNATIONS. 3 POS PRINTERS(I-G.) '2' 1 08 20/1 B 1.35 4 0 W BY THE LOCAL AUTHORITY HAVING JURISDICTION. D. WHEN WORK IS COMPLETE, BALANCE THE CONTINUOUS LOAD ON EACH PHASE OF ALL M - MOTION ACTIVATED LIGHTING SWITCH (WATT STOPPER #DW-100 OR EQUAL). 5 SANDWICH TOP'8' 0-94 20/1 C 1.35 6 O PANELBOARDS. 20/2 HOT HOLDING TABLE'S DUPLEX RECEPTACLE FLUSH !N WALL AT 24" A.F.F. UNLESS OTHERWISE NOTED. A "C" 9. AFTER INSTALLATION BUT PRIOR TO ENERGIZATION, PERFORM TESTS FOR GROUNDS, SHORTC 7 ICE MAKER 1.61 20/1 A 1.35 8 CIRCUITS AND PROPER FUNCTION. FAULTS IN THE INSTALLATION SHALL BE CORRECTED. ® DESIGNATION INDICATES INSTALLATION 7" ABOVE COUNTER. A "G" DESIGNATION INDICATES Lu D M E. PROVIDE ENGRAVED NAMEPLATE MATCHING PANELBOARD DESIGNATION ON THE 9 EXHAUST FAN'13.1' 0.12 2011 B 3.00 10 (CFI} PROVISION OF A GFCI TYPE RECEPTACLE. VERIFY FINAL LOCATION W/ TENANT. (\I DRAWINGS. 30/2 TURBO CHEF'12' CV 10. PROVIDE NAMEPLATES ON NEW OR EXISTING SAFETY SWITCHES, CONTROL PANELS, CONTROL 0 11 RETHERM. (I G) '14' 0.30 20/1 C 3.00 12 m Q V) DEVICES, JUNCTION AND PULL BOXES. LETTERING SHALL INCLUDE NAME OF EQUIPMENT, m SINGLE RECEPTACLE FLUSH IN WALL AT 24" A.F.F. OR AS NOTED. VERIFY FINAL LOCATION z 13 WATER HEATER 0.74 2011 A SPACE 14 r-i HORSEPOWER, VOLTAGE RATING AND SERVICE DESIGNATION. NAMEPLATES SHALL BE W/ TENANT. cy SECTION LIGHTING TEA SERVER'24' 0.24 20/1 B SPACE 16 * LA 0 I2 LAMINATED PHENOLIC WITH A BLACK SURFACE AND WHITE CORE. NAMEPLATES MAY BE 15 : DOUBLE DUPLEX RECEPTACLE FLUSH IN WALL AT 24" A.F.F.VERIFY FINAL LOCATION W/ L� a ATTACHED TO WALL ADJACENT TO EQUIPMENT IF AREA FOR ATTACHMENT IS TOO SMALL. 17 SODA DISPENSER'28' 0.25 20/1 C 1.05 18 %4118°,:, IDENTIFICATION WITH A DYMO TYPE INSTRUMENT IS NOT PERMISSIBLE. 1. LIGHT FIXTURES (LUMINAIRE) SHALL BE AS SPECIFIED ON THE LIGHTING FIXTURE SCHEDULE 20/2 CONVECTION OVEN'26L TENANT. z V AS INDICATED ON THE DRAWINGS. WHERE FIXTURE TYPES ARE INDICATED AS A 19 REACH-IN REFRIG. 1.56 20/1 A 1.45 I 20 0 z Q MANUFACTURER'S SERIES THE CONTRACTOR SHALL PROVIDE THE CORRECT TRIM, MOUNTING 21 RETH CTRL(1.G) '35' 0.30 2011 B 1.39 22 ® SPECIAL PURPOSE, SINGLE RECEPTACLE - NEMA TYPE A5 INDICATED.VERIFY FINAL 11. BEFORE FINAL PAYMENT, DEMONSTRATE TO THE OWNER'S SATISFACTION THE PROPER HARDWARE, APPURTENANCES, LENGTHS, ETC., TO COMPLETE THE INSTALLATION AS 'WALK IN FREEZER LOCATION W/ TENANT. O _ OPERATION OF EACH OF THE SYSTEMS COMPRISING THIS CONTRACT. INSTRUCT THE 23 CARBONATOR 1-20 20/1 C 35/3 1.39 24 l/•} Q INDICATED ON THE ELECTRICAL/ARCHITECTURAL DRAWINGS. CONDENSER'36' JUNCTION BOX - VERIFY FINAL LOCATION W/ TENANT Z Q VI OWNER'S MAINTENANCE PERSONNEL IN THE OPERATION AND MAINTENANCE OF ALL MICROWAVE'34' 1.20 20/1 A 1.39 26 ELECTRICAL EQUIPMENT AND CONTROLS. 25 I '_' 2. FLUORESCENT FIXTURES SHALL HAVE THERMALLY PROTECTED, HIGH POWER FACTOR (>99%), 27 W/I FREEZER LTG/HTR 1.50 20/1 B 20 2 1.00 WALK-IN FREEZER 28 ® OCCUPANCY SENSOR. I ~ 12. AFTER ALL TESTS HAVE BEEN COMPLETED, CLEAN ALL EQUIPMENT LEAVING EVERYTHING IN U.L. LISTED, CLASS P, COM, ETL, AND CSA CERTIFIED, ONE, TWO, THREE, AND/OR FOUR 29 SPARE 20/1 C 1.00 EVAPORATOR'36' 30 C1) WORKING ORDER AT THE COMPLETION OF THIS WORK. ALL ELECTRICAL EQUIPMENT SHALL LAMP (A5 REQUIRED), RAPID START, PARALLEL, HIGH FREQUENCY, T-8, ELECTRONIC (<10% 31 SPARE 2011 A 20/1 SPARE 32 i FLUSH MOUNTED ELECTRICAL PANELBOARD. REFER TO PANEL SCHEDULE. (DESIGNATION AS Q BE COMPLETELY CLEANED INSIDE AND OUT PRIOR TO INITIAL ENERGIZING. THD) BALLASTS, WITH 5 YEAR MINIMUM WARRANTY. APPROVED MANUFACTURERS SHALL BE - INDICATED). V) 33 SPARE 20/1 B 20/1 SPARE 34 MAGNETEK/TRIAD HP, OR ADVANCE GENTIUM. O 13. AVOID CUTTING INTO THE WORK OF OTHERS BY USING SLEEVES, INSERTS, CHASES AND 35 SPARE 20/1 C 20/1 SPARE 36 FUSED/ UNFUSED ITEMS NECESSARY FOR THE INSTALLATION. EXCEPT WHERE OTHERWISE SPECIFIED 3. COMPACT FLUORESCENT AND/OR T-5 FLUORESCENT FIXTURES SHALL HAVE THERMALLY 37 ( Q, FUSEDUNFUSED DISCONNECT SWITCH SPARE 20/1W A 20/1 SPARE 38 COMBINATION VOICE AND/OR DATA OUTLET BOX MOUNTED AT 18" A.F.F. INSTALLED IN A r-I OR NOTED ON DRAWINGS, THE ELECTRICAL CONTRACTOR SHALL PERFORM ALL CUTTING AND PROTECTED, HIGH POWER FACTOR (>98%), U.L. LISTED, CLASS P, CBM, ETL, AND CSA (3) 4S DP (MINIMUM) WITH SINGLE GANG TRIM RING. PROVIDE 3 4" CONDUIT ROUTED TO PATCHING OF THE BUILDING AS REQUIRED TO INSTALL SLEEVES, INSERTS, CONDUITS AND 39 SPARE 20/1T B 20/1 SPARE 40 / / 1-1 ELECTRICAL EQUIPMENT. PATCHING SHALL BE DONE BY SKILLED MECHANICS. WORK CERTIFIED, ONE, TWO, AND/OR THREE LAMP (AS REQUIRED), RAPID START, PARALLEL, HIGH 41 SPARE 2011 C 20/1 SPARE 42 TELEPHONE BACKBOARD. A "W" DESIGNATION INDICATES WALL TELEPHONE INSTALLED SHALL MATCH THE GENERAL CONSTRUCTION WORK. ALL CUTTING SHALL BE DONE IN A FREQUENCY, ELECTRONIC (<20%) BALLASTS. APPROVED MANUFACTURERS SHALL BE - - - - - 48" A.F.F. MOTOROLA, ENERGY SAVING INC., OR ROBERTSON. TOTALS (KW) 1.50 1.80 7.72 0.00 0.74 PH 0.00 0.00 20.47 0.00 0.00 TOTALS (KW) MANNER TO RETAIN THE STRUCTURAL INTEGRITY OF THE UNIT BEING CUT. WHERE (3) - INDICATES 3 DATA PORTS EXISTING EQUIPMENT IS REMOVED OR RELOCATED, PATCH TO MATCH THE EXISTING 4. LAMPS OO DUCT TYPE SMOKE DETECTOR BUILDING FINISHES (WALLS, CEILINGS, FLOORS, ETC.). LOAD SUMMARY PANEL DATA TOTAL LTG REC FSEOHVAC MISC Y 14. GUARANTEE ALL WORKMANSHIP AND MATERIALS PROVIDED UNDER THE CONTRACT FOR ONE a. PROVIDE ALL LAMPS REQUIRED. AT THE CONCLUSION OF THE WORK, EACH FIXTURE KWC DF KWD X 125% KW Phase A: 11.4 0.0 0.7 9.9 0.0 0.7 MUST BE EQUIPPED WITH THE PROPER NUMBER OF NEW LAMPS OF THE CORRECT 0 FIRE ALARM PULL STATION INSTALLED 42" A.F.F. MARK: ISSUE: DATE: LTG 1.5 1-25 1.9 KW Phase B: 10.0 1.5 1.1 7.4 0.0 0.0 YEAR AFTER ACCEPTANCE BY THE OWNER AND COMPLETION OF ALL PUNCH LIST ITEMS. SIZE AND TYPE, ALL IN GOOD OPERATING CONDITION. PERMIT 02/23/16 REPAIR OR REPLACE ANY DEFECT WITHOUT COST TO THE OWNER. REC 1.8 NEC 1 8 KW Phase C: 10.9 0.0 0.0 10.9 0.0 0.0 DI FIRE ALARM AUDIO/VISUAL UNIT INSTALLED 80" A.F.F. - _- 15. PROVIDE TEMPORARY ELECTRIC SERVICE OF SUFFICIENT CAPACITY TO SUPPLY THE ELECTRIC b. INCANDESCENT LAMPS SHALL BE 130 VOLT ONLY. FSEQ 28.2 0.65 18.3 _ El> FIRE ALARM VISUAL ONLY DEVICE INSTALLED 80" A.F.F. LIGHT AND POWER REQUIREMENTS OF CONSTRUCTION SITE, HVAC 0.0 1.00 0.0 c. FLUORESCENT LAMPS SHALL BE T-8, SP35 MEDIUM BI-PIN LAMPS WITH A CRI-85 MISC 0.7 0 70 0 5 TRI-PHOSPHOR COATING. APPROVED FLUORESCENT LAMP MANUFACTURERS SHALL BE 0 CEILING MOUNTED HORN/STROBE DEVICE. SECTION BASIC MATERIALS AND METHODS G.E., PHILIPS, OR OSRAM/SYLVANIA. TOTAL 32.2 22.5 28.1 AMPS 89.5A 62.5A 78.1A 1. EQUIPMENT AND MATERIAL USED ON THIS PROJECT SHALL BE NEW AND U.L. LABELED FOR d. COMPACT FLUORESCENT LAMPS SHALL CONTAIN AMALGAM ADDITIVES AND BE - THE APPLICATION. PROVIDED WITH END OF LIFE PROTECTION. LAMP COLORS SHALL BE SP27 WITH A - CRI-82. APPROVED COMPACT FLUORESCENT LAMP MANUFACTURERS SHALL BE G.E., 2. ALL FEEDERS AND BRANCH CIRCUITS SHALL BE INSTALLED IN CONDUIT. CONDUIT SHALL BE PHILIPS, OR OSRAM/SYLVANIA. PANEL SCHEDULE NOTES: EXISTING TENANT RIGID GALVANIZED, INTERMEDIATE OR EMT. CONDUITS SHALL BE 3/4" TRADE SIZE MINIMUM, DISTRIBUTION PANEL AND UNLESS OTHERWISE NOTED ON THE DRAWINGS OR IN THESE SPECIFICATIONS. 5. ALL FIXTURES SHALL BE SECURELY SUPPORTED WITH APPROVED HANGERS. FIXTURES 0 PROVIDE GFCI BREAKER FOR 120 VOLT RECEPTACLE CIRCUITS IN FOOD SERVICE/KITCHENS (AS DEFINED PER N.E.C. LANDLORD TO PROVIDE RELATED UTILITY METERING SHALL BE SUPPORTED FROM STRUCTURAL CEILING OR STRUCTURAL SUPPORTS, NOT200A PANEL WITH FEEDER, SUSPENDED CEILING SUPPORTS. FLUORESCENT RECESSED FIXTURES MUST BE SUPPORTED #210.8) FOR ALL FOOD PREP AREAS, BEVERAGE DISPENSING IN ADDITION TO DEVICES WITHIN 6' OF SINKS. THE E.C. TO REMOVE METER, ETC. 3. WIRE AND CABLE FOR POWER AND LIGHTING FEEDERS LARGER THAN #6AWG SHALL BE AT THE FOUR CORNERS AND SECURED TO CEILING SUPPORTS IN ACCORDANCE WITH THE EXISTING 200A PANEL AND COPPER STRANDED 600 VOLT TYPE THHN/THWN OR XHHW COPPER. WIRE AND CABLE N.E.C. SURFACE MOUNTED FIXTURES MUST HAVE ADDITIONAL CEILING SUPPORT AS 0 PANEL ENCLOSURES/TUBS TO BE PROVIDED BY LANDLORD. ALL CIRCUIT BREAKERS TO BE PROVIDED BY THE E.C. EXTEND FEEDER TO NEW FOR POWER AND LIGHTING BRANCH CIRCUITS SHALL BE THHN/THWN COPPER FOR #10 ACCEPTABLE BY THE ARCHITECT. PANEL "B" LOCATION O AND SMALLER AND THHW OR XHHW COPPER FOR #8 AND LARGER. MINIMUM WIRE SIZE PROJECT#: FOR POWER AND LIGHTING CIRCUITS SHALL BE #12. N N SECTION COMMUNICATIONS RACEWAY SYSTEM 4. ALL LOW VOLTAGE WIRING SHALL BE U.L. PLENUM RATED AND INSTALLED IN COMPLIANCE B I- B -I A O ® DRAWN BY: CHECKED BY: WITH N.E.C. SECTIONS #300.22 AND #760.30(B)(1). 1. THE CONTRACTOR SHALL PROVIDE COMBINATION VOICE AND/OR DATA OUTLETS, JACKS, I-- - --I A 00 CABLING, TERMINATIONS TESTING, BOXES, CONDUIT, MISCELLANEOUS FITTINGS, MATERIALS, 200A I 20 0 00A I Arkinetics,Inc.and their Consultants shall be deemed the authors 200A and owners of their respective Instruments of Service and shall 5. ARMORED (TYPE AC) CABLE OR METAL CLAD (TYPE MC) CABLE MAY BE USED IN LIEU OF ETC. IN ACCORDANCE WITH OWNER'S REQUIREMENTS AND AS INDICATED ON THESE 1 I c' -lciEll ■ retain all common law,statutory and other reserved rights,including N BRANCH CIRCUIT CONDUIT. HOWEVER, THE INSTALLATION OF CABLE ASSEMBLIES SHALL DRAWINGS. I I O O copyrights The Instruments of Service shall not obether used for future O COMPLY WITH ARTICLE 320 AND 330 OF THE NATIONAL ELECTRICAL CODE RESPECTIVELY. L-_ the additionsioror alterations to t o Project isofor other unauthocts,iwithoutuse\ the prior written agreement of Arkinetics,Inc.Any unauthorized us C TYPE OF WIRING SHALL BE AS SPECIFIED ELSEWHERE IN THIS SECTION. A GREEN 2. COMBINATION VOICE AND/OR DATA OUTLET BOXES SHALL BE 4 INCHES SQUARE WITH I i cCEI ■ of the Instruments of service shall beat the owners sole risk and 71 EQUIPMENT GROUNDING CONDUCTOR SHALL BE PROVIDED IN ALL MC CABLE AND AC r without liability to Arkinetics,Inc.and their Consultants Q SINGLE GANG PLASTER RING. TELEPHONE, DATA AND FAX OUTLETS SHALL BE SIMILAR. a eva �`` arkinetics o 2016 N CABLE. THE BLANK COVERPLATE SHALL BE PROVIDED FOR ALL UNUSED OUTLETS. I9 400/31 W C� DRAWING TITLE: -1 6. ALL BOXES SHALL BE RIGIDLY SUPPORTED FROM BUILDING STRUCTURE INDEPENDENT OF 3. ALL CONDUITS REQUIRED FOR TELEPHONE OUTLETS AS SHOWN ON THE DRAWINGS SHALL 5 THE CONDUIT SYSTEM. ALL BOXES SHALL BE 4" SQUARE BOXES MINIMUM WITH RAISED BE PROVIDED COMPLETE WITH PULL STRINGS. CONDUITS SHALL BE 3/4" (1") MINIMUM. la n e Electrical Specifications D COVERPLATE SUITABLE FOR WALL MATERIAL TO ALLOW BOX TO BE FLUSH. PROVIDE CONDUIT FROM EACH OUTLET TO ABOVE THE ACCESSIBLE FURNISHED CEILING. 0 EXISTING GROUNDING a a PROVIDE AN INSULATED BUSHING ON THE END OF THE CONDUIT. PROVIDE CONDUIT WITH ELECTRODE SYSTEM TO 7. LOCAL LIGHT SWITCHES SHALL BE BACK AND SIDE WIRED, 20 AMPERE, 120/277 VOLTS, A PULL STRING. O , REMAIN (UNDERGROUND XI AC, "COMMERCIAL GRADE". PASS & SEYMOUR #12211/12231 SERIES. METAL WATER PIPE, -171 • BUILDING STEEL, REBAR IN rn 8. DUPLEX RECEPTACLES SHALL BE "COMMERCIAL GRADE" 20 AMPERES, 125 VOLT, 3 WIRE, CONCRETE FOOTING AND K GROUNDING TYPE. PASS & SEYMOUR #5362I SERIES. O DRIVEN GROUND RODS) U) 9. INDOOR AND RECEPTACLES, WHERE REQUIRED BY LOCAL CODE, SHALL HAVE INTEGRAL mGROUND FAULT CIRCUIT INTERRUPTER OR GROUND FAULT CIRCUIT INTERRUPTER CIRCUIT SHEET#: BREAKER PROTECTION. GROUND FAULT CIRCUIT INTERRUPTER RECEPTACLES, WHERE REQUIRED, SHALL BE PASS & SEYMOUR #53621-IG. PROVIDE PULLBOX (SIZED POWER DISTRIBUTION DIAGRAM PER N.E.C. ) AND EXTEND E. 101 8 200 AMP FEEDER. (208/120V-30---4W) NO SCALE N Fl TURF SCHEDULE GENERAL NOTES GENERAL NOTES: GENERAL NOTES QED PROF 1. SUPPORT ALL ELECTRICAL EQUIPMENT AND WIRING 1. ELECTRICAL SERVICE SHALL BE VERIFIED ON SITE. ••\° 6 1 N F `SS/ N OTE: ALL FIXTURES ARE TO BE SUPPLIED BY ELECTRICAL CONTRACTOR 1. AS REFERRED TO HEREIN, 'CONTRACTOR' SHALL BE DEEMED AS ELECTRICAL CONTRACTOR. (INC LOW VOLTAGE) IN ACCORDANCE WITH NEC �� F O ARTICLE 300-11. 2. THE ELECTRICAL CONTRACTOR SHALL COMPLY WITH AND <ci ACUITY GT4MV 2X4 LENSED TROFFER WITH (4) 28W, SUPER T8, 2. SUBMITTAL OF BID INDICATES CONTRACTOR IS COGNIZANT OF ALL JOB SITE CONDITIONS AND WORK TO ALL WORK AND MATERIALS SHALL CONFORM TO THE :;5: PE "A" 0 LINEAR, 41K FLUORESCENT STRAIGHT LAMPS INCLUDED. BE PERFORMED UNDER THIS CONTRACT. 2. ALL RECESSED LIGHTING FIXTURES IN DROP REQUIREMENTS OF ALL APPLICABLE FEDERAL, STATE AND ,I CEILING TO HAVE PAINTED TRIM RINGS TO MATCH s; e e. 97 WATT. 3. ALL MOUNTING HEIGHTS SHALL BE VERIFIED WITH OWNER PRIOR TO INSTALLATION. / LOCAL LAWS, OF THE NATIONAL BOARD OF FIRE _ CEILING COLOR, W BLACK BAFFLE RUST-OLEUM UNDERWRITERS, THE NATIONAL ELECTRICAL CODE, THE 9 It JUNO NXPB3RBL THERMOPLASTIC LED EXIT SIGN 4. THESE PLANS ARE SCHEMATIC ONLY, FOLLOW AS CLOSELY AS POSSIBLE. "FOSSIL" SATIN FINISH. NATIONAL SAFETY CODE, A.LE.E. AND OSHA. C/�� r 4 2�P�� 5. EACH CONDUCTOR OF EVERY SYSTEM SHALL BE PERMANENTLY TAGGED IN EACH PANEL BOARD, PULL 3. CONNECT ALL EXIT LIGHTING AND EMERGENCY, *_/?, 41 H. SHIP JUNO NXPC3RBL EXIT AND EMERGENCY COMBO UNIT BOX, J-BOX, ETC. IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970. BATTERY LIGHTS TO LOCAL LIGHTING CIRCUITS 3. THE CONTRACTOR SHALL OBTAIN ALL PERMITS AND EXPIRES 06/30/2016 AHEAD OF SWITCHING. CERTIFICATES OF INSPECTION FOR ALL WORK. 6. CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, INSURANCE, EQUIPMENT, INSTALLATION, <?7„);71A'N •> CONSTRUCTION TOOLS, TRANSPORTATION, ETC. FOR A COMPLETE AND PROPERLY OPERATING SYSTEM AS 4. VERIFY EXISTING GROUNDING SERVICE, REPAIR OR 4. SHOULD ANY FIELD CONDITIONS PREVENT THE JUNO N1BL EMERGENCY "BUG EYE" LIGHT FIXTURE - WALL MOUNTED INDICATED ON THESE DRAWINGS AND AS SPECIFIED HEREIN AND/OR AS REQUIRED BY CODE. REPLACE PER NEC. 1999. INSTALLATION OF UTILITIES SHOWN, THE CONTRACTOR IS SEAL 7. ALL MATERIALS SHALL BE NEW AND IN EXCELLENT CONDITION WHEN INSTALLED AND SHALL BE OF THE REQUIRED TO MAKE ANY MINOR DEVIATIONS THERE FROM BEST GRADE ANO OF THE SAME MANUFACTURER THROUGHOUT FOR EACH CLASS OR GROUP OF5. ALL WIRE TO BE COPPER, TYPE "THHN". AS DETERMINED BY THE OWNER WITHOUT ANY ADDITIONAL 4/X)TJUNO PGZHTR INDOOR/OUTDOOR EMERGENCY COST. � LIGHTING UNIT Y 'UNDERWRITER'S LAORATORIES', AN SQHA LMBEAR hTHEERINSPECTION LABELS SWHERE SUBJATIALS SHALL BE LITED ANDECTP TOO SUCCHAPRVEDBAPPROVAL. MATERIA SBSSHALLL MEET WITDH 6. EXISTING SERVICE PANEL TO BE FIELD VERIFIED. EM CEIL THE APPROVAL OF THE DIVISION OF INDUSTRIAL SAFETY AND ALL GOVERNING BODIES HAVING 7. ALL TRACK AND FIXTURES TO BE BLACK. 5. THE CONTRACTOR SHALL VISIT THE PROJECT SITE AND 1::= JUNO N1BL EMERGENCY "BUG EYE" LIGHT FIXTURE - CEILING JURISDICTION. MATERIALS SHALL BE MANUFACTURED IN ACCORDANCE WITH THE APPLICABLE STANDARDSSHALL EXAMINE TO HIS SATISFACTION ALL OF THE MOUNTED ESTABLISHED BY A.N.S.I., N.E.M.A. AND N.B.F.U. _ 8. HEIGHT MEASURED TO CENTER OF OUTLET BOX, PHYSICAL CONDITIONS. 0 Cil? 6, 6 JUNG IC22 24BLWH LED LAMPS INCLUDED, 6" IC HOUSING, AND CONICAL BLACK BAFFLE. 8. ALL CONDUIT SHALL BE INSTALLED CONCEALED WHERE PHYSICALLY POSSIBLE. ALL EXPOSED CONDUIT UNLESS OTHERWISE NOTED. M ' o 0 N- ____. 0 LAMPS ARE LED PAR38 30K - 50,000 HOURS. SHALL BE INSTALLED PARALLEL OR AT RIGHT ANGLES WITH THE BUILDING WALLS. 6. ELECTRICAL CONTRACTOR SHALL GUARANTEE AGAINST O 00 e0 0 CD 17 WATT 9. ALL FIXTURES SUPPLIED BY ELECTRICIAN. MECHANICAL AND ELECTRICAL DEFECTS OF ANY OR ALL a c� a_ , (6 � 9. THE CONTRACTOR SHALL CARRY OUT HIS WORK IN ACCORDANCE WITH ALL STATE, COUNTY, LOCAL EQUIPMENT, MATERIALS AND WORKMANSHIP. i W .� LLQ N '71- JUNO IC22/24BLWH LED LAMPS INCLUDED, 6" IC HOUSING, AND CONICAL BLACK BAFFLE. CODES AND OSHA. O 0 LAMPS ARELED PAR38 41 K - 50,000 HOURS. * THESE NOTES APPLY TO ALL DRAWINGS AND ARE N C cJ o NOT SPECIFICALLY REFERENCED. 7. ALL WIRING TO BE #12 UNLESS OTHERWISE NOTED. o t ., Ei cr 17 WATT 10. THE CONTRACTOR SHALL SECURE ALL NECESSARY BUILDING PERMITS AND UTILITY CHARGES AND PAY FOR SAME. 0 . > 0 J N J IL STRAND BLACK MINI PENDANT, LED LAMPS INCLUDED, DARK BRZ/AMBER * THESE NOTES APPLY TO ALL DRAWINGS AND ARE NOT ui ART/GLASS, 30K - 25,000 HOURS. 11. THE COMPLETE JOB SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR AFTER THE DATE OF SPECIFICALLY REFERENCED. + U B 13 WATT ACCEPTANCE BY THE OWNER. ANY WORK, EQUIPMENT OR MATERIALS FOUND TO BE FAULTY DURING THIS Cf0 ❑_ PERIOD SHALL BE CORRECTED AT ONCE UPON WRITTEN NOTIFICATION, AT THE EXPENSE OF THE • a) CONTRACTOR. II =MO fp } o '- STRANO BLACK MINI PENDANT, LED LAMPS INCLUDED, DARK BRZ/AMBER I .' 2 ART/GLASS, WITH TRACK MOUNT ACCESSORIES, 30K - 25,000 HOURS. 12. CONTRACTOR TO PROVIDE THE OWNER WITH ONE (1) SET OF COMPLETE ELECTRICAL 'AS BUILT' = E. '- 13 WATT DRAWINGS AT THE COMPLETION OF THE JOB, SHOWING ACTUAL ROUGH IN DIMENSIONS. L ;' o 13. ALL CIRCUIT BREAKERS SHALL BE 10,000 A.I.C., PLUG IN, U.L. LABELED 'SW' FOR ALL LIGHTING 0 .g- r SURFACE MOUNTED TRACK FIXTURE LOW VOLTAGE LED LIGHTING SHALL BE 0d m O ' Qo 0 �? 6i �? JUNO REDUCED PROFILE, SINGLE-CIRCUIT TRACK CIRCUIT BREAKERS. SERVED BY SAME CIRCUIT AS SERVING p o = co c) „F„ #R701 BL, LOW VOLTAGE MR16 CYLINDER, LED LAMP INCLUDED, MR16 LED 14. USE T-TAP CONNECTIONS ON ALL MULTI-CIRCUITS WITH COMMON NEUTRAL CONDUCTORS FOR ALL AREA. LIGHTING IN SERVING AREA IS O CE O N` C' FLOOD, 30K - 25,000 HOURS. 7 W/HEAD __ a) - rn co LIGHTING CIRCUIT BREAKERS. CONTROLLED BY SWITCH 2, A/ -- t� illil UM UM 1111 3 4? JUNOAREDUCED CE TPROFILE, SINGLE-CIRCUIT TRACK 15, ALL RECESSED FIXTURES SHALL BE U.L. LABELED FOR THE AREAS IN WHICH THEY ARE INSTALLEDII ED TACK FIXTURE � � a_ � c� (.6 LOCATION, THERMAL PROTECTION, ETC.) LED TRANSFORMER (PROVIDE SWITCHED #8541 BL, LED LAMP INCLUDED, DRAWN STEEL UNIVERSAL TRACK (I.E.:DAMP ME ai co a) NRI "F-C" LIGHT, BULB REFLECTOR LED, 41K - 25,000 HOURS. OUTLET AT EACH TRANSFORMER LOCATION. Q U co U ti Ci 12 W/HEAD 16. THE CONTRACTOR SHALL FURNISH AND INSTALL ALL POWER, CONTROL WIRES, CONDUIT AND OUTLETS TO CONNECT TO SWITCH "32" SERVING AREA RENDER MECHANICAL EQUIPMENT COMPLETE AND OPERATIVE. REFER TO THE MECHANICAL DRAWINGS FOR LIGHTS (TYPICAL) 0 R1 CONTEMPORARY PENDANT #17374-K0434 LED, LAMP/MOUNTING INCLUDED LOCATION OF EQUIPMENT, CONTROLS, AND CONTROL SCHEMATICS. 0 KICHLER - WALL MOUNTED, BATH LIGHT FIXTURE #45118N1 WITH LED LAMPS LIGHTING PLAN NOTES: INCLUDED, BRUSHED NICKEL FINISS, LED A LAMP, 41K - 25,000 HOURS. PROJECT: O CONNECT ALL EMERGENCY EGRESS LIGHTING TO NIGHT LIGHTING CIRCUIT A/#2 OR AHEAD OF LOCAL IIW-1 ACUITY - 2'X4' LENSED TROFFER, #GT4MV, 2 BALLAST LAMPS INCLUDED 1/3, 1 LIGHTING PER STATE AND LOCAL CODES. ALL EMERGENCY EGRESS BATTERIES SHALL PROVIDE POWER 4 LAMP BALLAST, LINEAR FLUORESCENT STRAIGHT LAMP, 41K. FOR A DURATION OF NOT LESS THAN 90 MINUTES. 0 A/#1 INDICATES CIRCUIT BREAKER #1 IN PANEL "A", O ROUTE CEILING LIGHTING CIRCUIT TO LED LIGHTS ON COUNTER SYSTEM. 0 CIRCUITS TO PANEL "B" WILL HAVE A DESIGNATION "B" NEXT TO CIRCUIT NUMBER SEE DETAIL ON THIS SHEET FOR ADDITIONAL INFORMATION. • • INDICATES 2-POLE CIRCUIT BREAKER #2,4 IN PANEL "A", W CIRCUITS TO PANEL "B" A/#2,4 3 WILL HAVE A DESIGNATION "B" NEXT TO CIRCUIT NUMBER 0 12'-0" TRACK MOUNTED TO BACK OF HEADER CENTERED OVER SOUP COUNTER: "HAND OVER COUNTER". 1- <Q INDICATES 2-POLE CIRCUIT BREAKER #2,4 IN PANEL "A", A/#6,8,10 CIRCUITS TO PANEL "B" WILL HAVE A DESIGNATION "B" NEXT TO CIRCUIT NUMBER 0 CONNECT ALL NIGHT LIGHTING TO PANEL "A", CIRCUIT #2. FOR 2'x4' FLUORESCENT LIGHTINGw � m CONNECT TO LIGHTING IN SERVINGCC NJ CONTACT: FIXTURES, (1) LAMP SHALL BE WIRED FOR NIGHT LIGHTING. AREA. SERVING AREA LIGHTING LED U N D E RC O U N T E R LIGHTING PLAN m < O' N FIXTURES ARE BEING CONTROLLED I� LEFF ELECTRIC NATIONAL ACCOUNTS O ,--I PHONE E 800.686.5333 5 4'-0" TRACK MOUNTED TO BACK OF HEADER CENTERED OVER SOUP COUNTER: HAND OVER BY SWITCH #2, AND WIRED TO SCALE: 1/4" = 1' 0" o- \ Z dl FAX - 216.661.6292 COUNTER". PANEL "A", CIRCUIT #11. 2 c O EMAIL - nationalaccounts@leffelectric.com IH ~ SHANNON SKODA - 216.325.1597 O 8'-0" TRACK MOUNTED TO BACK OF HEADER CENTERED OVER SOUP & P.O.S. COUNTER. NOTE: z O JIM MILLIGAN - 216.310.2040 LED LIGHTS ARE INCLUDED WITH MILLWORK e� Q 0 z 0 O7 4'-O" BLACK TRACK CENTERED ON LOGO. G.C. TO COORDINATE LOCATION. PACKAGE AND PRE-INSTALLED. E.C. `\ice ~ ~ I 8 DOWNLIGHTS IN DINING AREA SHALL BE ALTERNATELY SWITCHED "56 & S7" TO COMPLY WITH RESPONSIBILITY IS TO PROVIDE SWITCHED Q Ln OUTLETS AS INDICATED. z Q LIGHTING REDUCTION PER IECC. SWITCH DESIGNATION AS INDICATED NEXT TO LIGHTING FIXTURE. - i I- ° PROVIDE A MONOPOINT CONNECTION FOR TRACK FIXTURE CENTERED ON BOOTH. (!'l Q 0 8'-0" CEILING MOUNTED TRACK. LI) O 0 6'-O" CEILING MOUNTED TRACK. Cr O A/#g r-I 1 1 : _. I-i -1 -t- 1'-'4-1.---fill'. 1 - i - I_►I a- - I 7I Ill • • RI CD B ; -- S6 I< 1 O O 0 L-7,_:.17.1,__-T I' 1.d_ :_,-„L Ii 11_47H ,LiJ-- ' . . B/#27 II O O MARK: ISSUE: DATE: I1 S6&7 �, O LIGHTS AND - DOOR HTR PERMIT • 02/23/16 illill 1 A/#7 B S7 S6 S7 S6 S7 EM 0 0* O O r '. - 1: . NL mE. I 10 0 IR - - 1 I1 ♦ 1 i R1 S7 S6 I = S6 1 S7 � I I �� -1 O O .. O __ O 1 I I II 0 - - -- - - 1 NL --� -- I- 41- - -1 - - _-, O S6 S7 : :S6 : : -- . . : : _ I S • S6 . S7 S6 0 © I O O EM ENI . . . . . . - _ . . S7 S6 53 OO •■ PROJECT#: fib56 f1 1 S7 O ODRAWN BY: CHECKED BY: 0 : : • • 0 II 0 .---...- -- 1--- S1 NL I. A/#1 Arkinetics,Inc.and their Consultants shall be deemed the authors B ! "SPa° •► �+ �+ `i `r `a� `f `r �r `� �� 11 and owners of their respective Instruments of Service and shall 10 i- ll I �. F--C F-C F-C F-C F- EM F-C F-C F-C F-C F-C F-C F-C F-C © Ee•s1 Ff}55 retain all common law,statutory and other reserved rights,including 0 I, '' .1-.- copyrights.The Instruments of Service shall not be used for future N U I 11 1 04S209-S6copyrights. or alterations to this Project or for other projects.without 0 Eft 5357 the prior written agreement of Arkinetics,Inc.Any unauthorized use C I. S S6 la 0 0 0 0 0 0 EftS4EP}58 of the Instruments of Service shall be at the Owner's sole risk and O NL O NL without liability to Arkinetics,Inc-and their Consultants N B 0 0 A, arkinetics 2016 �;� w i I F-C EM NL DRAWING TITLE: D B f -c EM A AJA EM EM Lighting Plan 54 �, Al 0 0 0 0 0 0 NL I,1 O F-c ,-, o . .. 1 A/#13 0 0 0 : 0 -- _ 111 i l: _ u . 1 I s S2 U) S5 0 A/#11 W A/#5 LIGHTING PLAN SHEET : 1 010 • SCALE: 1/4" = 1' 0E. 1 0 2 rn N N -n - MEDIA PLAYER #1 J--j DIGITAL MENU BOARD #1 1 GENERAL ELECTRICAL NOTES: —1 MEDIA PLAYER #21--1 DIGITAL MENU BOARD #2 I '��..D PROFFS —I MEDIA PLAYER #3-4 DIGITAL MENU BOARD #3 CONNECTION TYPE f 1. ELECTRICAL SERVICE SHALL BE VERIFIED ON SITE. ����RG I N 6., 0/0 .--- RECEPTACLE SWITCH OTHER SOUP SOUP SALAD OMS RETHERM OFFICE HIGH x. CIRCUIT 2. THE ELECTRICAL CONTRACTOR SHALL COMPLY WITH AND ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS J59 r, CHIT LABEL SANDWICH EXPO CPU CPU SPEED VOLTAGE o w o 0 o a a o z o OF ALL APPLICABLE FEDERAL, STATE AND LOCAL LAWS, ORDINANCES REGULATIONS, AS WELL AS THE RULES AND BREAKER OR PRINTER PRINTER LABEL CPU OVEH DESCRIPTION AND PHASE KW HP `i o cy ,_._, T w N J i' J C) E ; o MOUNTINGEiGHCONDUIT AND WIRE SIZE PANEL CIRCUITOSWITCH/FUSE NOTES STANDARDS OF THE NATIONAL BOARD OF FIRE UNDERWRITERS, THE NATIONAL ELECTRICAL CODE, THE NATIONAL SAFETY ,. UPS I PRINTER (SOYA) # Lo ¢ c9 [D c� co c� cc w z z �' b Fs, 1 z � z z , , ¢ Q z SIZE CODE, A.I.E.E. AND OSHA. fO < 1-n < < 1 < in \ < I- d z c) ! 17 � N. �0 PRINTER POS #1 w m m m o 1 Z o z i 14 F'� MAIN _ z c' z z z z `D - o 3. THE CONTRACTOR SHALL OBTAIN ALL PERMITS AND CERTIFICATES OF INSPECTION FOR ALL WORK. -1 4,7 11 Sµ�QP 1 PUS MONITOR (1.0.) 120V-10 0.060 - • 18" 2#12, 1#12(G), 3/4"C. B 1 20A-1P 1 4. SHOULD ANY FIELD CONDITIONS PREVENT THE INSTALLATION OF UTILITIES SHOWN, THE CONTRACTOR IS REQUIRED TO MAKE EXPIRES:06:30Z16 POS #1 POS MONITOR (1.0.) 120V-10 0.060 - • 18" 2#12, 1#12(G), 3/4"C. B 1 20A-1P 1 ANY MINOR DEVIATIONS THEREFROM AS DETERMINED BY THE OWNER WITHOUT ANY ADDITIONAL COST, SPARE - ISP LINES CONTRACTOR TO RUN 1 CAT6 LINES TO NETWORK RACK POS MONITOR (1.0.) 120V-10 0.060 - • 18" 2#12, 1#12(G), 3/4"C. B 1 20A-1P 1 5. THE CONTRACTOR SHALL VISIT THE PROJECT SITE AND SHALL EXAMINE TO HIS SATISFACTION ALL OF THE PHYSICAL SEAL ISP LINE CO TRUNKS POS MONITOR (I.G.) 120V-10 0.060 - • 18" 2#12, 1#12(G), 3/4"C. B 1 20A-1P 1 CONDITIONS. UPS J - 24 PORT UNLOADED PATCH PANEL 2 POS PRINTER1.G. 120V-10 0.0242#12, 1#12(G), 3/4"C. 8 3 20A-1 P 1• 18" PRINTER _POS #2 PRINTER (1.0.) 6. ELECTRICAL CONTRACTOR SHALL GUARANTEE AGAINST MECHANICAL AND ELECTRICAL DEFECTS OF ANY OR ALL EQUIPMENT, MAIN H24 PORT NETWORK SWITCHF POS PRINTER (1.0.) 120V-10 0.024 - • 18" 2#12, 1#12(G), 3/4"C. B 3 20A-1P 1 MATERIALS AND WORKMANSHIP. (ZOUP SW02) ISP MODEM ISP COMPANY - 8 PORT NETWORK SWITCH Y I ALARM #DEMARCATION POS PRINTER (I.G.) 120V-10 0.024 - • 18" 2#12, 1#12(G), 3/4"C. B 3 20A-1P 1 7. ALL WIRING TO BE 12 UNLESS OTHERWISE NOTED. POS SPARE2 (zOUP swot) r VERIFY TYPE POS PRINTER (1.0.) 120V-10 0.024 - • 18" 2#12, 1#12(G), 3/4"C. B 3 20A-1P 1 c }, I E INTERNET OR " 8. ALL DEVICES RECEPTACLES TO BE IVORY IN COLOR UNLESS OTHERWISE NOTED. COVER PLATES TO BE STAINLESS STEEL. 41) MUZAK CELL SERVICE) POS PRINTER (I.G.) 120V-10 0.024 - • 18 2#12, 1#12(G), 3/4"C. B 3 20A-1 P 1 20 N- -FIREWALL WIRELESS CAMERAS AND WIRING BY °� ¢ o 'UPS I POS PRINTER (I.G.) 120V-10 0.024 - • 18" 2#12, 1#12(G), 3/4"C. B 3 20A-1 P 1 C1 CD s ROUTER (FW01) SECURITY CONSULTANT ___ POWER AND COMMUNICATIONS PLAN NOTES: $ cD ca PRINTER _POS #3 I 0 ® 5 HOT HOLDING TABLE 208V-10 2.704 = • 18" 2#12, 1#12(G), 3/4"C. B 2,4 20A-2P 1,6 ! I� 42 0LE •cr O 0 cc' civ MAIN UPS (ZOUP BRUT) O LOCATION OF EXISTING ELECTRICAL PANELS. SEE POWER RISER DIAGRAM ON DRAWING #E-101 FOR ADDITIONAL a) N o 0 HOT HOLDING TABLE 208V-10 2.704 • 1$ 2#12, 1#12(G), 3/4 C. B 6,8 20A-2P 1,6 1= r . .� COAX CABLE INFORMATION. MAINTAIN ALL CLEARANCES PER N.E.C. #110.26 0 E c� c>� v cr DVR CPU (OPTIONAL) 8 SANDWICH TOP 120V-10 0.936 - •• 18" 2#12, 1#12(G), 3/4"C. B 5 20A-1P 1,6 . n .' I:(3 a 0 0 POS 3 (QSEE) NETWORK i J �' J a. L� # . 0 ® O2 BASE BID: PROVIDE PHOTOCELL FOR EXTERIOR SIGNAGE CONTROL. +, SPARE RACK C-6 11 ICE MAKER 120V-10 1.608 - • 60" 2#12, 1#12(G), 3/4"C. B 7 20A--1P 1,6 BID ALTERNATE: PROVIDE PHOTOCELL "ON", TIMECLOCK "OFF" FOR EXTERIOR SIGNAGE CONTROL WHEN LOCAL JURISDICTION cciii (f) * = OPTIONAL 12 TURBO CHEF 208V-10 6.000 - • 18" (B.O.R.) 2#10, 1#10(G), 3/4"C. B 10,12 30A-2P 1 OR LANDLORD DOES NOT ALLOW EXTERIOR SIGNAGE TO BE ON THROUGHOUT THE NIGHT. C }U-. MULTI- VOIP HANDSET 13.1 EXHAUST FAN 120V-100.120 - • 18" (B.O.R.) 2#10, 1#10(G), 3/4"C- B 9 20A-1P 1,2 NETWORK AND PHONE LINE DROPS TO PHONE BOARD. SEE LOW VOLTAGE DIAGRAM ON THIS SHEET FOR ADDITIONAL a FUNCTION VOIP HANDSET O INFORMATION. 3/4" CONDUITS TO JB FOR LOW VOLTAGE CABLE, PROVIDE PULL CORD TO ABOVE CEILING. _ PRINTER 14 RETHERMALIZER (I.G.) 120V-10 0.300 - • 18" 2#12, 1#12(G) 3/4"C. B 11 20-1P 1Mit A 23 WATER HEATER 120-10 0.744 - • 60" 2#12, 1#12(G), 3/4"C. B 13 20A-1P 1 O (3) 3/4" CONDUITS FOR LOW VOLTAGE CABLE, PROVIDE PULL CORD TO ABOVE CEILING; FOR EACH POS STATION. L -c 0 o _ . _ c 24 TEA SERVER 120V-10 0.240 - • 18" 2#12, 1#12(G), 3/4"C. B 15 20A-1P 1 o 0 LOW VOLTAGE WIRING DIAGRAM 26L CONVECTION OVEN 208V-10 2.900 - • 18" 2#12, 1#12(G), 3/4"C. B 18,20 20A-2P 1 O WIRE CEILING DISPLAY RECEPTACLES THROUGH SWITCH "SS" LOCATED AT SWITCH BANK. Cy - c O o co 0 NO SCALE O SIGN CIRCUIT TO 24HR TIMER AT PANEL. VERIFY LOCATION WITH SIGN MANUFACTURER. a� 0 Qi r' cii- 28 SODA DISPENSER 120V-10 0.252 - • 18" 2#12, 1#12(G} 3/4"C. B 17 20A-1 P 1IT:i - 29 CARBONATOR ABOVE B.I.B. 120V-10 1.200 - • 72" 2#12, 1#12(G), 3/4"C. B 23 20A-1P 1 O COORDINATE OUTLET LOCATIONS WITH MILLWORK (TYPICAL). M css m c4 (6 LOW VOLTAGE WIRING DIAGRAM NOTES: '= > c� m N tv 32 REACH-IN REFRIGERATOR 120V-10 1.560 - • 48" 2#12, 1#12(G), 3/4"C. B 19 20A-1P 1 a) � m 1. ALL NETWORK WIRING TO BE CAT6/6 O ALL OUTLET COVERS THROUGHOUT TO BE S.S. ■ il 34 MICROWAVE 120V-10 1.200 - • 18" 2#12, 1#12(G), 3/4"C- B 25 20A-1P 1 ¢ U c� U Q IL 2. ALL NETWORK CABLING RUNS TO PHONE BOARD LOCATION TO HAVE 5' OF SLACK 35 RETHERM. CONTROL (I.G.) 120V-10 '0.300 - • V 48" 2 12, 1#12(G) 3/4"C. B 21 ` 20-1 P 1 O ELECTRICIAN IS RESPONSIBLE FOR CONNECTION OE ALL CONTROL WIRING, HEAT TAPE, AND LIGHTING CIRCUITS. REFER TO # LIGHTING PLAN FOR LIGHTING CIRCUIT NUMBER. 3. ALL NETWORK CABLING TO TERMINATE TO A RJ-45 JACK (BY GENERAL CONTRACTOR) 36 W/I FREEZER - FAN 208V--10 -1.997 - • AT UNIT 2#12, 1#12(G), 3/4"C. B 28,30 20A-2P 1,2,4 10 ALL DEVICES THROUGHOUT TO BE IVORY. 4. ALL LINES TO BE TAGGED AND NUMBERED AT BOTH ENDS OF TERMINATION (BY CONTRACTOR). W/I FREEZER - COMP. 208V-30 4.176 - • AT UNIT 3#12, 1#12(G), 3/4"C- B 22,24,26 35A-3P 1,3 ED THERMOSTAT, DUCT DETECTORS, AND REMOTE TEST STATIONS TO BE INSTALLED BY MECHANICAL CONTRACTOR AND WIRED PROJECT: 5. ALL RJ45 JACK WIRING TO BE TERMINATED AT THE WALL BOARD WHERE THE DATA RACK WILL BE BY ELECTRICAL CONTRACTOR. ROUTE HOMERUN FOR DUCT DETECTORS TO PANEL A/#4. INCLUDE ALL WORK, WIRING, LOCATED. ALL JACKS SHOULD BE ABLE TO PLUG INTO EMPTY PATCH PANEL. CAT6/6 DATA, USOC FOOD SERVICE CONNECTION SCHEDULE NOTES: COMPONENTS, ETC. FOR CONNECTION TO BUILDING FIRE ALARM SYSTEM WHERE PRESENT. 0 6. PLEASE PROVIDE AT LEAST 5' OF SERVICE LOOP AS THE DATA AND VOICE TECHNICIANS WILL PLACE THE 12 NEW ROOFTOP UNIT "RTU-1" (208V-30. 42.3A MCA/50A MOCP): CONNECT TO FACTORY MOUNTED UNFUSED DISCONNECT Q TERMINATED CABLES INTO THE 24 PORT UNLOADED PATCH PANEL 1. THE ELECTRICAL CONTRACTOR SHALL COORDINATE AND CONFIRM ALL ELECTRICAL SPECIFICATIONS, CONNECTIONS, ROUGH-IN REQUIREMENTS, MOUNTING HEIGHTS, CORD TYPES/LENGTHS, MOUNTING SWITCH. WIRING SHALL BE 3#6, 1#10(G), 3/4"C. 0 HEIGHTS, ETC. WITH THE FOOD SERVICE EQUIPMENT CONTRACTOR (F.S.E.C.) PRIOR TO PLACING PURCHASE ORDER FOR ANY DEVICES, DISTRIBUTION EQUIPMENT AND ROUGH-IN. FIXTURE AND EQUIPMENT LOCATIONS SHOWN ARE SCHEMATIC IN NATURE. COORDINATE FINAL CONFIGURATION & LOCATIONS WITH OWNER PRIOR TO BID SUBMISSION. 13 NOT USED O W DATA SCHEDULE 2. PROVIDE 100 WATT, A19 LAMPS FOR INTEGRAL LIGHT FIXTURES IN RESPECTIVE EXHAUST HOOD AND WALK-IN COOLERS. O Q JACK EQUIPMENT PATCH PANEL SWITCH SWITCH CONNECTION 3. PROVIDE A HEAVY DUTY DISCONNECT SWITCH (TYPE & SIZE PER SCHEDULE). MOUNT ON/AT UNIT AND BRANCH TO FINAL CONNECTION VIA LIQUIDTIGHT FLEXIBLE METALLIC CONDUIT. 14 PROVIDE CODE REQUIRED GFCI PROTECTED, WEATHERPROOF ROOFTOP RECEPTACLE AND CONNECT TO A#17. W01 fir'1 NO. PORT # PORT # RESPONSIBILITYN 4. PROVIDE A MANUAL MOTOR STARTER MOUNTED AT FANS FOR DISCONNECTING MEANS. INCLUDE THERMAL OVERLOADS SIZED PER NAMEPLATE RATING. 15 PROVIDE 'PUTTY PADS', OR, OTHER FIRE RATED MATERIAL FOR ALL DEVICES, WORK BOXES, ETC. LOCATED IN FIRE RATED m < l ) 1,:.\,..i D1 POS #1 MAIN PORT #1 SW02 PORT #1 NEXTEP DEMISING WALL. TYPICALLY 3M FIRE BARRIER MOLDABLE PUTTY PADS OR SIMILAR MATERIAL AS MANUFACTURED BY HILTI- D2 P05 #1 SPARE PORT #2 SWO2 PORT #2 NEXTEP 5. INSTALL CONVENIENCE OUTLET 48" A.F.F. CONNECT TO BRANCH CIRCUIT INDICATED ON DRAWING. 16 Q NOT USED. 0\ r CY O D3 POS #2 MAIN PORT #3 SW02 PORT #3 NEXTEP ; I- D4 a CDPOS #2 SPARE PORT #4 SW02 PORT #4 NEXTEP 6. INCLUDE COST OF CONNECTING A TYPE "SO" CORD AND MATCHING PLUG TO UNIT. THE E.C. SHALL REFER TO ARCHITECTURAL ELEVATIONS FOR THE EXACT LOCATION OF ALL DEVICES LOCATED ON THIS WALL. z O o z_ o D5 POS #3 MAIN PORT #5 SW02 PORT #5 NEXTEP 7. PROVIDE NEMA 3R WALLBOX AND BRANCH TO FINAL CONNECTION VIA LIQUIDTIGHT, FLEXIBLE METALLIC CONDUIT. INCLUDE ALL WIRING AND INSTALLATION OF RELATED SOLENOID VALVES, CONTROL 18 DEVICE TO BE LOCATED 6" TO 8" OFF OF CENTERLINE OF TABLE/TABLE SUPPORT. VERIFY EXACT LOCATION PRIOR TOP Z 0 ~ _ D6 POS #3 SPARE PORT #6 SW02 PORT #6 NEXTEP STATION, ETC. IN ACCORDANCE WITH MANUFACTURER'S WIRING DIAGRAM. ROUGH-IN. LI) u' Q D7 MULTI FUNCTION PRINTER PORT #7 SW01 PORT #1 BIND z < LD D8 MEDIA PLAYER #1 PORT #8 SW02 PORT #8 NEXTEP 0A/#12 = 1- D9 MEDIA PLAYER #2 PORT #9 SW02 PORT #9 NEXTEP 24" A.F.F. LA D10 MEDIA PLAYER 3 PORT #10 SW02 PORT #10 NEXTEP I '-- _______11..____________________0_______________,- _.IJP __ _ _- ( - Q # A/#10® ��} 1-: -.:117:471-, r 11 1- 1=� !�1 ,1 I --c -.:711- -, - - — _-i_ _ GFCI --- P1 : (� D11 SOUP CHIT PRINTER PORT #11 SW02 PORT #11 NEXTEP - I I= — .. 1-,---14-_-_-A = 84" _ III i 4� � Imo: . -, � ...: ��4-,..•� D12 SOUP LABEL PRINTER PORT #12 cp _ SW02 PORT #12 NEXTEP [11L JI A/#10 _ 11 GFCII I � " i 1`11 - D13 SOUP SANDWICH LABEL PRINTI=R PORT #13 5W02 PORT 13 NEXTEP II � � I Il IYI i � it: I�l� 36�• 1111— — IAPPROXIMATE LOCATION I ] �# L-- -1L-r_ ,- ,' II I }' h# II i L. t I --- L ij -._ I CO REMOTE WALK-IN SO I - 1 O D14 OMS EXPO CPU PORT #14 SW02 PORT #14 NEXTEP I I n — "` � !` COOLER COMPRESSORD15 RETHERM CPU PORT #15 SWO2 PORT #15 NEXTEP 111 III ,11 A/#14 �� J LOCATED ON ROOF J rL_ _ I �© 016 OFFICE CPU PORT #16 SW01 PORT 2 BIND I I LI017 VOIP HANDSET PORT #17 SW01 PORT #3 BIND 1-1 .I 1 - LiD18 VOIP HANDSET PORT #18 SW01 PORT #4 BIND -I-- - -- — n I II 1'-_L_. �_ i I 1 '1 I 1 �I 1.. _ — N/A MUZAK N/A SW01 PORT #5 MUZAK ,. u I - I I = 1 I I I 1 —I.— � 9 B/ 27 I i,lr I- I I 1 I i.l L _ MARK: ISSUE: DATE: N/A I 1 �1 �.,I I ~� PERMIT 02/23/16 N/A ALARM N/A SW01 PORT #6 ALARM COMPANY 1,= 1 114—_,. ! 1 I ' II I I 1 I I P I ] — N/A FIREWALL N/A SW02 PORT #24 BIND -" :• L — I I I 11 I I II I Tij I } S $ I GFCI GFCI LOCATION OF BUILDING N/A FIREWALL N/A SW01 PORT #8 BIND A/#14 ) III - - - -- - -- • - -- - - - - - -- L 4-F= ._ • 36" 84" O - MAIN ELECTRICAL ROOM - -- �I} _�.__.� - - - - - - - -�Y4-�-:W--. -_-_.-• @ _ --------44 I " h. . Ili 111 AND RELATED TENANT I I DISTRIBUTION. 13.1 I A/#8 �'v®E A 27 11101= 0 ©� ©� . . • • • • • • 2 1 '®...' ■� I � (3)EACH DROPSI (3) DROPS (3) DROPS IU 14 � -_� ' - --- EACH EACH (2) DROPS 2 A/#10® I I ,_,,ME \ - -• LOCATION °CATION LOCATION L - - __ _.. J @A/#8 _EE � 72" 1Y • •..• EC..1._07 ldl J'ii- • ....... ...... . .. .. . . . .. . . .. . .. .. ... .. . ..... . . .. .. 1g II I , !, ! . ,,1 7 ....... . . . . . . . .... ... . . . . .........-,.-- 484 II I L U CAT6 6l_iiIt[_I_!_ '-1!_y_,I� 1II A 8 �,i I,i Ij II �1 'ii r 1CI I! it ® PROJECT#: II1-L /# DRAWN BY: CHECKED BY: 118" B.O.R. Arkinetics,Inc.and their Consultants shall be deemed the authors 11 `� _ PO5 O32and owners of their respective Instruments of Service and shall IIS ( retain all common law,statutory and other reserved rights,including _ PRNT RJ-4copyrights.The Instruments of Service shall not be used for future N II E I II — - A 6 A/#29 additions or alterations to this Project or for other projects,without j I�l�{ /# © 23 the prior written agreement of Arkinetics.Inc.Any unauthorized use 0 II I IMOM ' 1� of the Instruments of Service shall be at the Owner's safe risk and Ih..I _ - e without liability to Arkinetics.Inc-and their Consultants I y1....]I A 10 I I' 11 L. ■IIF — ' — arkinetics©2016 co �,1 ' I1 .... . I I 1 (3) , i ® .� 111 _III__ III _____.1117 111 711 48' 48' 96' 48" rtr _. - A/�19 A/�I19 A19 DRAWING TITLE: s42-A.F.E_ 102" A.F.F. D I 0 +102n CAT6 RJ-45 (2) DROPS ( ) I Power & Communications Plan ® DIGITAL MENUBOARD J 0 28 24 0 POWER PLAN " oll4141-1.-ti ®m SCALE: 1/4" = 1'-0" In = ROOFTOP UNIT LOCATED ABOVE WP ADJACENT TENANT SPACE. VERIFY rn H ",. '"{:e „„, • RTU-1 EXACT LOCATION IONFIELD SHEET t`: w • rn RP E. 103 N) W T1