Loading...
Report (105) .kk .U, - 1 f ‘CA-‘:- CSV -?x-Nd 'l€..COMcheck Software Version 4.1.0.0 (1Envelope Compliance certificate Section 1: Project Information ' Energy Code:2014 Oregon Energy Efficiency Specialty Code AUG G 2 1 ?018 Project Title:72nd Avenue Apartments Project Type: New Construction Envelope Compliance Method:Simplified Trade-Off ' li i7Tx`:` ' 'p ;' „ Construction Site: Owner/Agent: Designer/Contractor: 11740 SW 72nd Avenue Richard Cassinelli Lloyd Hill Tigard,OR 97232 72nd Avenue Property LLC Hill Architects 4804 NW Bethany Boulevard,1-2 1750 Blankenship Road,Suite 400 Portland,OR 97229 West Linn,OR 97068 rec65@me.com 503.305.8033 503.545.5217 Iloyd.hill@hillarchitects.com Building Location(for weather data): Tigard,Oregon Climate Zone: 4c Vertical Glazing/Wall Area Pct.: 36% Building Use:Area Type Floor Area 1-Multifamily:Residential 32462 2-Retail:Nonresidential 2321 3-Exercise Center:Nonresidential 389 4-Dining:Bar Lounge/Leisure:Nonresidential 389 Section 2: Envelope Assemblies and Requirements Checklist Envelope PASSES: Design 0.4%better than code. Envelope Assemblies: Component Name/Description Gross Cavity Cont. Proposed Budget Area or R-Value R-Value U-Factor U-Factor(a) Perimeter Roof 1:Attic Roof with Wood Joists,[Bldg.Use 1 -Multifamily] 8056 38.0 0.0 0.027 0.027 Exterior Wall 1;Wood-Framed, 16"o.c.,[Bldg.Use 1 -Multifamily] 16152 21.0 0.0 0.062 0.064 Window 1:Vinyl/Fiberglass Frame:Fixed,Peri.Specs.:Product ID 3038 --- --- 0.300 0.350 ECO Windows,SHGC 0.35,[Bldg.Use 1 -Multifamily](b) Door 1:Glass(>50%glazing):Nonmetal Frame,Non-Entrance 1950 -- -- 0.300 0.350 Door,Peri.Specs.:Product ID ECO Windows,SHGC 0.35, [Bldg.Use 1 -Multifamily](b) Exterior Wall 2:Steel-Framed, 16"o.c.,[Bldg.Use 2-Retail] 1354 13.0 7.5 0.064 0.064 Window 2:Metal Frame Curtain Wall/Storefront,Pert.Specs.: 1310 --- --- 0.400 0.450 Product ID Kawneer+Cardinal,SHGC 0.30,[Bldg.Use 2- Retail](b) Exterior Wall 3:Wood-Framed, 16"o.c.,[Bldg.Use 3-Exercise 300 21.0 0.0 0.062 0.064 Center] Window 3:Vinyl/Fiberglass Frame,Pert.Specs.:Product ID ECO 35 --- --- 0.300 0.350 Windows,SHGC 0.35,[Bldg.Use 3-Exercise Center](b) Door 2:Glass(>50%glazing):Nonmetal Frame,Non-Entrance 93 -- --- 0.300 0.350 Door,Pert.Specs.:Product ID Slider,SHGC 0.35,[Bldg.Use 3- Exercise Center](b) Exterior Wall 4:Wood-Framed, 16"o.c.,[Bldg.Use 4-Dining:Bar 300 21.0 0.0 0.062 0.064 Lounge/Leisure] Window 4:Vinyl/Fiberglass Frame,Pert.Specs.:Product ID 35 --- --- 0.300 0.350 ECO Windows,SHGC 0.35, Bld .Use 4-Dining:Bar [ 9 9 Lounge/Leisure](b) Door 3:Glass(>50%glazing):Nonmetal Frame,Non-Entrance 93 --- --- 0.300 0.350 Door,Pert.Specs.:Product ID Slider,SHGC 0.35,[Bldg.Use 4- Dining:Bar Lounge/Leisure](b) Project Title: 72nd Avenue Apartments Report date: 08/20/18 Data filename:P:\2016_JOB\16761 72nd Avenue Apartments\2 Codes&Approvals\2.5 Code Analysis\COMcheck 2018-07-26\COMcheck I 2018-08-01.cck Page 1 of 3 Floor 1:Concrete Floor(over unconditioned space),[Bldg.Use 1 - 8056 --- 15.0 0.055 0.064 Multifamily] Floor 2:Slab-On-Grade:Unheated,[Bldg.Use 2-Retail] 354 — (a)Budget U-factors are used for software baseline calculations ONLY,and are not code requirements. (b)Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation. In the following requirements,blank checkboxes identify requirements that the applicant has not acknowledged as being met.Checkmarks identify requirements that the applicant acknowledges are met or excepted from compliance. 'Plans reference page/section'identifies where in the plans/specs the requirement can be verified as being satisfied. Fenestration Product Rating: • 1. U-factors of fenestration products(windows,doors and skylights)are determined in accordance with NFRC 100 by an accredited, independent laboratory,and labeled and certified by the manufacturer or are determined using the commercial size category values listed in Chapter 15 of the 2009 ASHRAE Handbook of Fundamentals,Table No.4 and shall include the effects of the window frame. The temporary label afixed to the fenestration products must not be removed prior to inspection. Plans reference page/section: Sheet A010-Energy Code Compliance Notes-Note#1 • 2. Solar heat gain coefficient(SHGC)of glazed fenestration products(windows,glazed doors and skylights)shall be determined in accordance with NFRC 200 by an accredited,independent laboratory,and labeled and certified by the manufacturer or be determined using the Solar Heat Gain Coefficients(SHGC)in Chapter 15 of the 2009 ASHRAE Handbook of Fundamentals,Table No.10.The overall values must consider type of frame material and operator for the SHGC at normal incidence. Plans reference page/section: Sheet A010-Energy Code Compliance Notes-Note#3 Air Leakage, Insulation, and Component Certification: ✓ 3. Sealing of the building envelope.Openings and penetrations in the building envelope are sealed with caulking materials or closed with gasketing systems compatible with the construction materials and location.Joints and seams are sealed in the same manner or taped or covered with a moisture vapor-permeable wrapping material.Sealing materials spanning joints between construction materials allow for expansion and contraction of the construction materials. Plans reference page/section: Sheet A010-Energy Code Compliance Notes-Note#4 ✓ 4. Window and door assemblies.The air leakage of window and sliding or swinging door assemblies that are part of the building envelope are determined in accordance with AAMA/WDMA/CSA 101/I.S.2/A440,or NFRC 400 by an accredited,independent laboratory,and labeled and certified by the manufacturer. Plans reference page/section: Sheet A010-Energy Code Compliance Notes-Note#5 ✓ 5. Curtain wall,storefront glazing and commercial entrance doors.Curtain wall,storefront glazing and commercial-glazed swinging entrance doors and revolving doors are tested for air leakage in accordance with ASTM E 283.For curtain walls and storefront glazing, the maximum air leakage rate is 0.3 cubic foot per minute per square foot of fenestration area.For commercial glazed swinging entrance doors and revolving doors,the maximum air leakage rate is 1.00 cfm/ft2 of door area. Plans reference page/section: Sheet A010-Energy Code Compliance Notes-Note#6 ✓ 6. Building thermal envelope insulation.An R-value identification mark is applied(by manufacturer)to each piece of insulation 12 inches or greater in width.Alternately,the insulation installers have provided a signed,dated and posted certification listing the type, manufacturer and R-value of insulation installed.Refer to code section for blown or sprayed insulation installation/settling depths and marker requirements. • 7. Insulation mark installation.Insulating materials are installed such that the manufacturer's R-value mark is readily observable upon inspection. ✓ 8. Insulation product rating.The thermal resistance(R-value)of insulation has been determined in accordance with the U.S.FTC R-value rule. • 9. Installation.All material,systems and equipment are installed in accordance with the manufacturer's installation instructions and the International Building Code. 10.Outdoor air intakes and exhaust openings.Stair and elevator shaft vents and other outdoor air intakes and exhaust openings integral to the building envelope shall be equipped with not less than a Class I motorized,leakage-rated damper with a maximum leakage rate of 4 cfm per square foot at 1.0 inch water gauge when tested in accordance with AMCA 500D.Stair and shaft vent dampers shall be capable of being automatically closed during normal building operation and interlocked to open as required by fire and smoke detection systems. Plans reference page/section: Sheet A010-Energy Code Compliance Notes-Note#7 ✓ 11.Loading dock weatherseals.Cargo doors and loading dock doors are equipped with weather seals to restrict infiltration when vehicles are parked in the doorway. Requirement is not applicable. Plans reference page/section: ✓ 12.Recessed lighting.Recessed luminaires installed in the building thermal envelope are sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires are IC-rated and labeled as meeting ASTM E 283.All recessed luminaires are sealed with a gasket or caulk between the housing and interior wall or ceiling covering. Project Title: 72nd Avenue Apartments Report date: 08/20/18 Data filename:P:\2016_JOB\16761 72nd Avenue Apartments\2 Codes&Approvals\2.5 Code Analysis\COMcheck 2018-07-26\COMcheck 2018-08-01.cck Page 2 of 3 Plans reference page/section:Electrical Plans 13.Vestibules.Doors that separate conditioned space from the exterior are protected with an enclosed vestibule,with all doors of the vestibule equipped with self-closing devices.Vestibules are designed so interior and exterior doors to not operate simultaneously. Requirement is not applicable. Plans reference page/section: 14.'Other'components have supporting documentation for proposed U-Factors. Requirement is not applicable. Plans reference page/section: Section 3: Compliance Statement Compliance Statement: The proposed envelope design represented in t <document is consistent with the building plans,specifications and other calculations submitted with this permit application.The pro•.sed e elope system has been designed to meet the 2014 Oregon Energy Efficiency Specialty Code requirements in COMcheck Versio 4 .0.0 :• corn. th- .atory requirements in the Requirements Checklist. //�� /'� Name-Title Signature Da 21124* Project Title:72nd Avenue Apartments Report date:08/20/18 Data filename:P:\2016 JO8\16761 72nd Avenue Apartments\2 Codes&Approvals\2.5 Code Analysis\COMcheck 2018-07-261COMcheck 2018-08-01.cck Page 3 of 3