Report (142) RECEIVED qu7SAr \53r3LS\c *Q-10 OOCT -2 2018 OFFICE Coity CITY OF TR MID BUILDING DIVISION #I•fr if;#1i . .. 'MATT FIRE PROTECTION, INC. 9095 S.W. Burnham Tigard, OR 97223 T-MOBILE WASHINGTON SQUARE 9693 SW WASHINGTON SQUARE RD TIGARD, OREGON 97223 FIRE PROTECTION EQUIPMENT SUBMITTAL tilco Worldwide Fire Protection Contacts www.tyco-fire.com Products Series RFII — 5.6 K-factor "Royal Flush II" Concealed Pendent Sprinklers Quick & Standard Response, Standard Coverage _ General tective Cap can be used to mark the center of the ceiling hole into plaster Description board or ceiling tiles by gently pushing p the ceiling product against the Pro The TYCO Series RFII 5.6 K-factor, tective Cap. When ceiling installa- tion is complete,the Protective Cap is "Royal Flush II" Concealed Pendent removed and the Cover Plate/Retainer Sprinklers Quick Response (3-mm :: bulb) and Standard Response (5-mm Assembly is installed. ¢ .. bulb), are decorative sprinklers fea- As an option,the Series RFII Standard ----',-- --,, turing a flat cover plate designed to Response(5-mm bulb)"Royal Flush II" conceal the sprinkler.These sprinklers Concealed Pendent Sprinklers can be are optimal for architecturally sensi- fitted with a silicone Air and Dust Seal. tive areas such as hotel lobbies, office (Refer to Figure 5.) The Air and Dust buildings, churches, and restaurants. Seal is intended for sensitive areas Technical Each sprinkler includes a Cover Plate/ where it is desirable to prevent air and Retainer Assembly and a Sprinkler! dust from the area above the ceiling to Data Support Cup Assembly. The separa- Pass through the cover plate. Sprinkler Approvals ble, two-piece assembly design pro NOTICE Approvals apply only to the service vides the following benefits: conditions indicated in the Design Criteria • Allows installation of the sprinklers The Series RFII Concealed Pendent section. and pressure testing of the fire pro- Sprinklers described herein must be • TY3531 (3 mm Bulb)is UL Listed, installed and maintained in compliance tection system prior to installation of C-UL Listed and NYC Approved 1 a suspended ceiling or application of with this document and with the appli (MEA 353-01-E)as Quick Response. the finish coating to a fixed ceiling. cable standards of the National Fire Protection Association, in addition to • TY3531 (3 mm Bulb)is VdS Approved • Permits the removal of suspended the standards of any authorities having (Certificate No.G4090007). ceiling panels for access to building jurisdiction.Failure to do so may impair • TY3531 (3 mm Bulb)is FM and service equipment without having the performance of these devices. LPCB Approved(Ref.No.094a/10) to first shut down the fire protection The owner is responsible for maintain as Standard Response. system and remove sprinklers. ing their fire protection system and Note:FM and LPCB do not approve • Provides for 1/2 inch (12,7 mm) devices in proper operating condition. concealed sprinklers for quick of vertical adjustment to allow a The installing contractor or sprinkler response. measure of flexibility in determining manufacturer should be contacted with • TY3551 (5 mm Bulb)is UL Listed, the length of fixed piping to cut for any questions. C-UL Listed,FM Approved,LPCB the sprinkler drops. Approved(Ref.No.094a/9),and The Series RFII Sprinklers are shipped Sprinkler NYC Approved(MEA 353-01-E)as with a Disposable Protective Cap.The Standard Response. Protective Cap is temporarily removed Identification Approvals for Air and Dust Seal during installation and replaced to help UL and C-UL Listed for use with the RFII protect the sprinkler during ceiling Number (SIN) Standard Response Concealed Sprinkler installation or finish.The tip of the Pro- (TY3551) TY3531 — 3 mm bulb Maximum Working Pressure TY3551 — 5 mm bulb Maximum 250 psi(17,3 bar)by UL, IMPORTANT C-UL,and NYC Always refer to Technical Data Maximum 175 psi(12,1 bar)by FM,VdS, Sheet TFP700 for the "INSTALLER and LPCB WARNING" that provides cautions Temperature Rating with respect to handling and instal- 155°F(68°C)Sprinkler with lation of sprinkler systems and com- 139°F(59°C)Plate ponents. Improper handling and 200°F(93°C)Sprinkler with installation can permanently damage 165°F(74°C)Plate a sprinkler system or its compo- nents and cause the sprinkler to fail Discharge Coefficient to operate in a fire situation or cause K=5.6 GPM/psi 2(80,6 LPM/bars z) it to operate prematurely. Page 1 of 4 APRIL 2016 TFP181 TFP181 Page 2 of 4 Adjustment 1/2" NPT r SEALING 1/2 inch(12,7 mm) , ASSEMBLY Finishes See the Ordering Procedure section �• Physical Characteristics FRAME j , ' Frame Bronze , CAP Support Cup Chrome Plated Steel '4-- A Guide Pins Stainless Steel Deflector Bronze SUPPORT Compression Screw Brass CUP WITH I I BULB Bulb Glass ROLL FORMED Cap Bronze or Copper Sealing Assembly..Beryllium Nickel w/TEFLON THREADS Cover Plate Brass O • Retainer Brass I I COMPRESSION Ejection Spring Stainless SteelGUIDE ! SCREW Design PINS(2) / '� Criteria 'a (DROPP DR The TYCO Series RFII 5.6 K-factor, DEFLECTOR , POSITION) "Royal Flush II" Concealed Pendent E=ti_r �_,--=' Sprinklers are intended for fire protec- tion systems designed in accordance SPRINKLER/SUPPORT CUP with the standard installation rules ASSEMBLY recognized by the applicable Listing or Approval agency; for example, UL THREAD INTO I RETAINER Listing is based on NFPA 13 and VdS SUPPORT ) I WITH THREAD Approval is based on the CEA 4001. CUP UNTIL t. O O � DIMPLES For more information on LPCB and VdS MOUNTING J Approvals,contact Tyco Fire Protection SURFACE IS EJECTION Products at the following office: FLCSH WITH SPRING CEILING Enschede, Netherlands Telephone: 31-53-428-4444 Fax:31-53-428-3377 17_S� `.�—„ The Series RFII Concealed Pendent Sprinklers are only listed and approved SOLDER COVER with the Series RFII Concealed Cover TABS(3) COVER PLATE/RETAINER PLATE Plates having a factory applied finish. ASSEMBLY FIGURE 1 NOTICE MODEL RFII CONCEALED SPRINKLER Do not use the Series RFII in applica- ASSEMBLY tions where the air pressure above the ceiling is greater than that below.Down Do not attempt to compensate for drafts through the Sprinkler/Support Installation insufficient adjustment in the Sprinkler Cup Assembly can delay sprinkler by under-or over-tightening the Sprin- operation in a fire situation. The TYCO Series RFII 5.6 K-factor, kler/Support Cup Assembly. Re-adjust "Royal Flush II" Concealed Pendent Sprinklers must be installed in accor the position of the sprinkler fitting to Operation dance with this section. suit. Step 1. positionsit the sprinkler only the When exposed to heat from a fire, the General Instructions Cover Plate, normally soldered to the Do not install any bulb-type sprinkler pendent with the center line Retainer at three points, falls awayto if the bulb is cracked or there is a loss mountingof the sprinkleruperpendicular to the surface. expose the Sprinkler/Support Cup of liquid from the bulb.With the sprin- Assembly. kler held horizontally,a small air bubble Step 2. Remove the Protective Cap. The Deflector — supported bythe should be present.The diameter of the Step 3. With pipe thread sealant pp air bubble is approximately 1/16 inch applied to the pipe threads, hand- Guide Pins — then drops down to its (1,6 mm)for the 155°F(68°C)and 3/32 tighten the sprinkler into the sprinkler operational position. inch(2,4 mm)for the 200°F(93°C)tem- fitting. The glass bulb contains a fluid that perature ratings. Step 4. Wrench-tighten the sprinkler expands when exposed to heat.When using only the RFII Sprinkler Wrench. the rated temperature is reached, the •A leak tight 1/2 inch NPT sprinkler (Refer to Figure 3.) Apply the RFII fluid expands sufficiently to shatter the joint should be obtained by applying a Sprinkler Wrench to the Sprinkler as glass bulb,activating the sprinkler and minimum to maximum torque of 7 to 14 shown in Figure 3. allowing water to flow. ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. TFP181 Page 3 of 4 FACE OF CLEARANCE HOLE CLEARANCE \SPRINKLER DIAMETER HOLE FITTING DIMENSION C SPRINKLER J iW SUPPORT CUP �7 1 ` ASSEMBLY 1/2"(12,7 mm) 1 (,11041 THREADED D ADJUSTMENT (1 At jr, FACE e- -- - -- " OF CEILING, RETAINING RING ( 7 --•,� A MOUNTING i SURFACE .1 FIGURE 4 \ / \ I I / DISPOSABLE PROTECTIVE CAP .54,\ 1I I Step 5. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. (Refer C- T_-1 to Figure 4.)The Protective Cap helps 3/16"to 11/16" MANUFACTURER DEFLECTOR COVER PLATE prevent damage to the Deflector and (4,8 to 17,5 mm) PRESET GAP IN DROPPED RETAINER Arms during ceiling installation and/or REFERENCE 3/32" (2,4 mm) POSITION ASSEMBLY finish.You can also use the Protective Cap to locate the center of the clear- COVER PLATE COVER PLATE ance hole by gently pushing the ceiling —PROFILE DEPTH DIAMETER material up against the center point of DIMENSION B DIMENSION A the Protective Cap. A:3-1/4 inches(82,6 mm) C:2-3/8 to 2-5/8 inches(60,3 to 66,7 mm) NOTICE B:3/16 inches(4,8 mm) D:1-3/4 to 2-1/4 inches(44,5 to 57,2 mm) As long as the Protective Cap remains in place, the system is considered "Out FIGURE 2 of Service". SERIES CONCEALED SPRINKLER INSTALLATION DIMENSIONS Step 6. After the ceiling has been completed with the 2-1/2 inch (63,5 mm) diameter clearance hole and in preparation for installing the Cover Plate/Retainer Assembly, remove and ill` FRAME Il�l,__ discard the Protective Cap.Verify that IIL , ARM % Fir the Deflector moves up and down / freely. If the Sprinkler is damaged and the SUPPORT iDeflector does not move u and down ) CUP ) freely, replace the entire Sprinkler. ' Do not attempt to modify or repair a MI damaged sprinkler. �� Step 7. When installing an Air and Mt Dust Seal, refer to Figure 5;otherwise 7/8"(23 mm) 0 proceed to Step 8.To attach the Air Amiih. SQUARE and Dust Seal, verify the angle of the outside edge of the seal is oriented according to Figure 5.Start the edge of ALIGN �J LT the Retainer in the grooved slot of the ARROWS WITH /(/ 1 1 \\ Air and Dust Seal and continue around FRAME ARMS JI \_ the retainer until the entire Air and Dust i ai Seal is engaged. I ACCEPTS \\ "::// 0 1/2"SOCKET \� DRIVE FIGURE 3 RFII SPRINKLER WRENCH TFP181 Page 4 of 4 Step 8. Screw on the Cover Plate/ SUPPORT — SPRINKLER FACE OF ORIENT Retainer Assembly until the Retainer CUP CEILING --SEAL (shown in Figure 2)or the Air and Dust BEVEL AS Seal (shown in Figure 5) contacts the l j� SHOWN l�i_-- ceiling.Do not continue to screw on the i 1 COVER r;) Cover Plate/Retainer Assembly so that PLATE it lifts a ceiling panel out of its normal j 111111 + RETAINER — position. If you cannot engage the VT �; ASSEMBLY • Cover Plate/Retainer Assembly with :, 0 the Support Cup or you cannot engage - the Cover Plate/Retainer Assembly suf ;j� ��� AIR ficiently to contact the ceiling,you must Ai ■ I� reposition the Sprinkler Fitting. =_r_.,` �Irr ��/ AND DUST _I •_—. t_= SEAL — _�� LIP OF COVER Care and RETAINER PLATE FIGURE 5 Maintenance OPTIONAL AIR AND DUST SEAL FOR SERIES RFII(TY3551) The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Care must be exercised to avoid Ordering Sprinklers must be maintained and damage to the sprinklers - before, serviced in accordance with this during, and after installation. Sprin- Procedure klers damaged by dropping, striking, section. wrench twist/slippage,or the like,must Before closing a fire protection system be replaced. Also, replace any sprin- Contact your local distributor for main control valve for maintenance kler that has a cracked bulb or that has availability. When placing an order, work on the fire protection system lost liquid from its bulb. (Ref. Installa- that the full product name. that it controls, obtain permission to tion Section.) Sprinkler/Support Cup Assembly shut down the affected fire protection Exercise care to avoid damage to sprin Specify: Series RFII (specify SIN), system from the proper authorities klers before, during, and after instal K=5.6, "Royal Flush II" Pendent Sprin- and notify all personnel who may be lation. Replace sprinklers damaged klers (specify) temperature rating and affected by this action. by dropping, striking, wrench twist (specify)finish, P/N*(specify): Absence of the Cover Plate/Retainer ing, wrench slipping, or the like. Also, 155°F(68°C) 200°F(93°C) Assembly can delay sprinkler opera- replace any sprinkler that has a cracked TY3531 51-792-1-155 51-792-1-200 tion in a fire situation. bulb or that has lost liquid from its bulb. TY3551 51-790-1-155 51-790-1-200 (Refer to the Installation section.) When properly installed, there is a - Use Suffix"I"for ISO 7-1 connection;for example, nominal 3/32 inch (2,4 mm) air gap If you must remove a sprinkler, do not 51-792-1-155-I between the lip of the Cover Plate and reinstall it or a replacement without Separately Ordered Cover Plate/ the ceiling,as shown in Figure 2. reinstalling the Cover Plate/Retainer Retainer Assembly: Assembly. If a Cover Plate/Retainer This air gap is necessary for proper Assembly becomes dislodged during Specify: (temperature rating from operation of the sprinkler. If the ceiling service,replace it immediately. below) Series RFII Concealed Cover requires repainting after sprinkler Plate with(finish), P/N (specify). installation, ensure that the new paint The owner is responsible for the 139°F(59°C)(a) 165°F(74°C)(b) does not seal off any of the air gap. inspection,testing,and maintenance of Grey White their fire protection system and devices (RAL9002) 56-792-0-135 56-792-0-165 Do not pull the Cover Plate relative to in compliance with this document, as Brass 56-792-1-135 56-792-1-165 the Enclosure.Separation may result. well as with the applicable standards Pure White(c) Sprinklers which are found to be of the National Fire Protection Asso- (RAL9010) 56-792-3-135 56-792-3-165 leaking or exhibiting visible signs of ciation (e.g., NFPA 25), in addition to Signal White corrosion must be replaced. the standards of any other authorities (RAL9003) 56-792-4-135 56-792-4-165 having jurisdiction.Contact the install- Jet Black Automatic sprinklers must never be ing contractor or sprinkler manufac- (RAL9005) 56-792-6-135 59-792-6-165 painted, plated, coated, or other- turer regarding any questions. Brushed wise altered after leaving the factory. p y Chrome 56-792-8-135 56-792-8-165 Modified sprinklers must be replaced. Automatic sprinkler systems should be Chrome 56-792-9-135 56-792-9-165 Sprinklers ers that have been exposed inspected,tested,and maintained by a Custom 56-792-X-135 56-792-X-165 p p qualified Inspection Service in accor- corrosive products of combustion, but dance with local requirements and/or (a) For use with 155°F(68°C)sprinklers. - have not operated,should be replaced national code. (b) For use with 200°F(93°C)sprinklers. if they cannot be completely cleaned (c) Eastern Hemisphere sales only. by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Limited Sprinkler Wrench Specify: RFII Wrench, Warranty P/NN556-0000--1-075 For warranty terms and conditions,visit Air and Dust Seal www.tyco-fire.com. Specify:Air and Dust Seal, P/N 56-908-1-001 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway,Lansdale,PA 194461 Telephone+1-215-362-0700 Copyright©2016 Tyco Fire Products,LP. All rights reserved. tyro TEFLON is trademark of The DuPont Corporation Fire Protection Products Eddyth read 40 A Lightweight Schedule 40 Replacement Pipe That Has a Corrosion Resistance Ratio of 1.0 Bull Moose Tube Company has been making pipe for a long time and is recognized as a producer of quality pipe products. Eddythread 40 is designed with the same thoroughness as our other fine pipe products and now our customers have an option to buy a carefully designed replacement for Schedule 40 that: • Has a Corrosion Resistance Ratio of 1.0 • Has a Pressure Rating of 300 psi • Is Lighter Weight Than Schedule 40 • Is Approved by Factory Mutual and Listed by Underwriters Laboratories • Is Produced in Accordance to ASTM A-135 and A-795 • Can be Used With Standard Schedule 40 Threaded Fittings, Couplings and Valves • Is Produced From Steel With Excellent Properties of Strength and Threadability • Can be Used in Wet, Dry, Preaction, and Deluge Type Sprinkler Systems* • Offers Lower Freight Costs EDDYTHREAD 40 SPECIFICATIONS 4,94' 1 1.461 1.083 70 1 1/4 2.070 1.418 51 1 1/2 2.547 1.654 44 2 3.308 2.123 30 CORROSION RESISTANCE RATIOS NOMINAL PIPE;' ,' 1 f 1.00 '<%.5 1.00 1 1/4 �� 1.00 R 1.00 ( 1/2 1.00 1.00 2 "4!� 1.00 1.00 *Eddythread 40 can be hot dipped galvanized to meet FM's requirement for dry systems �• 1819 Clarkson Road For additional information, C �� us Av��tA(� Chesterfield,MO 63017 contact your salesperson today at J BULL MOOSE TUBE COMPANY (800)325-4467 (800)325-4467 or(636)537-2600 LISTED V FAX:(636)537-2645 in the USA,or from Canada www.bullmoosetube.com call(800)882-4666 41> A LFAR )company e-mail:sales a,bullmoosetube.com APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 8/08 SMITHCooPE INTERNATIONAL Ductile Iron Threaded Fittings Specifications ;- • branded ductile iron threaded fittings are UL Listed and FM Approved at 500 psi • Rated to 300 WSP C43US • Ductile iron castings conform to ASTM A536 LISTED • Fitting dimensions conform to ASME B16.3 4(1;;• Bushings and plugs conform to ASME B16.14 • Fittings are 100% air tested APPROVED • NPT threads on all fittings conform to ASME B1.20.1 • Independent lab verification that fittings meet applicable chemical &physical properties • Manufacturing facilities are ISO 9001:2008 and ISO 14001 Temperature Working , psiG Degrees F 300# ClassPressureThreadedNonshock Fittings -20 to 100 500 k. -, 150 500 }_ 200 480 250 , 460 &-'\ �' .� 300 440 350 `44 _ 420 , . 400 400 A 450 380 , 500 360 550 ` 340 Wi :: 600 320 650 300 Ductile Iron Fittings- Class 300 UL/FM c ® us APPROVED Fig. 35E 3-90°Elbow LISTED A� Size A Packing Weight Part Number in in Inner Master lb __+ 1/2 35E 3004 1.13 100 200 0.2 1 314 35E 3006 1.31 70 140 0.3 i A 35E 3010 1.50 40 80 0.5 nin _ 1-1/4 35E 3012 1.75 25 50 0.8 1-1/2 35E 3014 1.94 18 36 1.1 2 35E 3020 2.25 10 20 1.8 2-1/2 35L 3024 2.70 4 8 3.2 Fig. 35RE3- 90°Reducing Elbow BSize Part Number A B Packing Weight in in in Inner Master lb I� 3/4 x 1/2 35003006004 1.20 1.22 80 160 0.3 I^ 1 x 1/2 35003010004 1.26 1.36 70 140 0.4 IA 1 x3/4 35003010006 1.38 1.45 50 100 04 �i1-1/4 x 1/2 35RE3012004 1.34 1.53 35 70 0.5 1-1/4 x 3/4 350E3012006 1.45 1.63 35 70 0.6 1-1/4 x 1 35RE3012010 1.58 1.67 30 60 0.7 1-1/2 x 1/2 35RE301 1004 1.52 1.75 30 60 0.6 1-1/2 x 3/4 35RE3014006 1.52 1,75 25 50 0.7 1-1/2 x 1 3500-3014010 1.65 1.80 20 40 0.8 1-1/2 x 1-1/4 35RE3014012 1.82 1,88 18 36 1.0 2 x1/2 350E3020004 1.60 1.97 18 36 1.0 2 x 3/4 35RE3020006 1.60 1.97 18 36 1.0 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 2 x 1-1/4 358E3020012 1.90 2.10 12 24 1.3 tili 2 x 1-1/2 35003020014 2.02 2.16 10 20 1.5 xxx x 2-1/2 x 1-1/2 35RE3024014 2.16 2.51 6 12 2.2 ;V 2-1/2 x 2 350E3024020 2.39 2.60 6 12 2.5 Fig. 35F 3-45°Elbow Size Part Number A Packing Weight q in in Inner Master lb 112 35F 3004 0-88 150 300 0.2 It 3/4 35F 3006 0.98 80 160 0.3 1 35F 3010 1 13 40 80 0.5 1-1/4 35F 3012 1.29 25 50 0.7 -1/2 351 3014 1.44 20 40 1.0 ��i IA 2 35F 3020 1.69 10 20 1.6 2-1/2 35F 3024 1-95 4 8 2.7 Fig. 35T 3- Tee - Size A Packing Weight dib Part Number -- in in Inner Master lb INC _ q 1/2 351 3004 13 80 160 0 3 3/4 35T 3006 1.31 30 60 000.53 5 �� �� 351 3010 1.50 25 50 0 7 Illiftrommomenilik 1-1/4 35T3012 1.75 10 20 1.1 A �� A 2 351 3014 94 0 20 1 5 2 3513020 2.25 6 12 2.4 ',1114 2-1/2 35T 3024 2.70 4 8 4,3 111 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com : Ductile Iron Fittings- Class 300 UL/FM c ® us APPROVED Fig. 35RT3-Reducing Tee LISTED Size Part Number A B C Packing Weight . a i in in inin Inner Master Ib � 3/4 x 1/2 35813006004 20 1,20 1.22 60 120 0.4 v 1 x 1/2 35RT3010004 1.26 1.26 1.36 30 60 0.6 x 1/2 x 1 35813010004010 1.50 1.36 50 30 60 0.6 1 x 3/4 35813010006 1.38 1.38 1.45 25 50 0.6 (--)i 1 x 3/4 x 3/4 35813010006006 1.38 1.31 1.45 35 70 0.6 B A 1 x 3/4 x 1 35873010006010 1.50 1.45 1.50 25 50 0.7 1-1/4x 1/2 35813012004 1.34 1.34 1.53 20 40 0.8 1-1/4 x 1/2 x 1-1/4 35R13012004012 1.75 1.53 1.75 25 50 0.9 1-1/4x3/4 35013012006 1.45 1.45 1.62 15 30 0.9 1-1/4 x 3/4 x 1-1I4 35813012006012 1.75 1.62 1.75 20 40 1.0 1-1/4 x 1 35813012010 1.58 1.58 1.67 15 30 1.0 1-1/4 x 1 x 1/2 35813012010004 1,34 1.26 1.53 25 50 0.7 1-1/4 x 1 x 3/4 35013012010006 1.45 1.38 1.63 20 40 0.8 1-1/4 x 1 x 1 35R13012010010 1.58 1.50 1.69 20 40 0.9 1-1/4 x 1 x 1-1/4 35813012010012 1.75 1.69 1.75 15 30 1.0 1-1/2 x 1/2 35813014004 1.41 1.41 1.66 16 32 1.0 1 1/2 x 1/2 x 1-1/4 35813014004012 1.81 1.56 1.88 24 48 1.1 1-1/2 x 1/2 x 1-1/2 35813014004014 1.94 1.66 1.94 12 24 1.2 1-1/2 x 3/4 35813014006 1,52 1.52 1.75 16 32 1.1 1-1/2 x 3/4 x 1-1/4 35R13014006012 1.94 1.66 1.88 20 40 1.1 1-1/2 x 3/4 x 1-1/2 35813014006014 1.94 1.75 1 94 18 36 1.7 1-1/2 x 1 35813014010 1.65 1.65 1.80 12 24 1.2 1-1/2 x 1 x 1/2 35843014010004 1.44 1,25 1.69 20 40 0.8 1-1;2x 1x3/4 35RT3014010006 1.50 1.44 1.75 16 32 0.9 1-1/2 x 1 x 1 35813014010010 1.65 1.50 1,80 16 32 1.0 1-1/2 x 1 x 1-1/4 35813014010012 1.82 1.67 1.88 12 24 1.2 1-1/2x 1 x 1-1/2 35813014010014 1.94 1.80 1-94 12 24 1.3 1-1/2 x 1-1/4 35R-13014012 1.82 1.82 1.88 12 24 1.4 11/2x1-1/4x1/2 35313014012004 1.41 1,34 1,66 16 32 0.9 1-1/2 x 1-1/4x 3/4 35813014012006 1.52 1.45 1.75 16 32 1.0 1-1/2x 1-1/4x 1 35013014012010 1.65 1.58 1,80 16 32 1.1 r 1-1/2 x 1-1/4 x 1-1/4 35R13014012012 1.82 1.75 1.88 14 28 1.3 41 1-112x1-1/4x11/2 35073014017014 1.94 1.88 1.94 14 28 1.4 2 x 1/2 35RT3020004 1.49 1.49 1.88 10 20 1.5 2 x 3l4 35813070006 1.60 1.60 1.97 10 20 1.6 _ 2 x 1 35813020010 1.73 1.73 2.02 8 16 1.7 2 x 1 x 2 35813020010020 2.25 2.02 2.25 8 16 1.9 2 x 1-1/4 35813020012 1.90 1.90 2.10 8 16 1.9 2 x 1 1/4 x 2 35813020012070 2.25 2.10 2.25 8 16 2.0 2 x 1-1/2 35R13020014 2.02 2.02 2.16 8 16 2.1 2 x i 1/2 x 112 35813020014004 1.49 1.41 1.88 10 20 1.3 2 x 1-1/2 x 3/4 35RT3020014006 1.60 1.52 1.97 10 20 1.4 2 x 1-1/2 x 1 35813020014010 1.73 1.65 2.02 8 16 1.5 2 x 1-1/2 x 1-1/4 35RT3020014012 1.90 1.82 2.10 8 16 1.7 2 x 1-1/2 x 1-1/7 35813020014014 2.02 1.94 216 8 16 1.8 Fig. 35RT3-Bull Head Tee , Size A B C Packing Weight 1 0.311111111 Part Number iC in in i in in Inner Master lb 3/4 x 1 35813006010 1.45 1 45 1,37 30 60 0.6 • 1111111 1 x 1-1/4 35313010012 1.67 1.67 1.58 20 40 0.9 1 x 1-1/2 350[3010011 1.80 1.80 1.65 15 30 1.0 f A)1< B > 1-1/4 x 1 x 1-1/2 35813012010014 1.88 1.80 1.82 15 30 1.2 1-1/4 x 1-1/2 35813012014 1.88 1.88 1 82 15 30 1.3 1-1/4 x2 35813012020 2.10 2.10 1.90 10 20 1.6 1-1/2 x 1-1/4 x 2 35813014012020 2.16 2.10 2.02 10 20 1.8 1-1/2 x 2 35813014020 2.16 2.16 2,02 8 16 1.8 S\11TH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • Si ww.smithcooper.com 112 S=QL Ductile Iron Fittings- Class 300 UL/FM j_QuAtram4i7 c ® us APPROVED A Fig. 35CP3 -Straight Coupling with Ribs LISTED ' Size Part Number A Packing Weight S in in Inner Master lb _ 1/2 35CP3004 1.38 200 400 0.1 3/4 35CP3006 1.63 100 200 0.2 1 35033010 1.75 60 120 0.4 1-1/4 35CP3012 2.00 35 70 0.5 • 1-1/2 35CP3014 2.19 25 50 0.7 2 35CP3020 2.62 15 30 1.2 2-1/2 35C83024 3.00 9 18 2.2 Fig. 35RC3 -Hex Reducing Coupling ilSize Part Number A Packing Weight Nim - in inInner Master lb A 1 x 1/2 35803010004 1 69 80 160 0.3 1 x 3/4 35R03010006 1.69 60 120 0.4 i 1-1/4 x 3/4 35803012006 2.06 40 80 0.6 2 x 1 (not hex) 35RC3020010 2.81 20 40 1.0 Fig. 35HB3 -Hex Bushing Size Part Number A Packing Weight B in in Inner Master lb 1 x 1/2 35H33010004 1.06 180 360 0.2 1 � � 1 x 3/4 35HB3010006 1.06 180 360 0.1 I � A j ' 1 1 i 1-1/4 x 1 35H B3012010 1.19 90 180 0.2 i 1-1/2 x 1 35HB3014010 1.25 75 150 0.4 1-1/2x1-1/4 35-B3014012 1.25 75 150 0.3 2 x 1 35HB302.0010 1.38 40 80 0.6 2 x 1-1/4 35HB3020012 1.38 40 80 0.6 2 x 1-1/2 35HB3020014 1.38 40 80 0.6 Fig. 35SP3 -Square Head Plug Size A Packing Weight Part Number in in Inner Master lb 1/2 35SP30040.94 600 1200 0.07 ie. .,0 __.i A 3/4 35SP3006 1.12 350 700 0.1 ' 1 35SP3010 1.25 200 400 0.1 i 1-1/4 35SP3012 1.37 100 200 0.3 1-1/2 35S83014 1,44 80 160 0.4 2 35SP302.0 1.50 45 90 0.6 Fig. 35U 3-Union with Brass Seat A Size Part Number A Packing Weight �R tnensin in Inner Master lb 1 3503010 2.19 20 40 0 � III ��� 11--11/,42 335U 30142 2.60 15 10 30 1.2 1.7 mahoraimal 2 35U 302.0 3.12 6 12 2.4 boo 113 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com pper; Fire . � .. C®08 FM VdS LPCD SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating 1/,3/4,and 1'/15,20 and 25 mm outlets for directly connecting sprinklers,drop nipples,sprigs,gauges,drains and other outlet products.Available for 11A through 76.1 mm/32 to 76.1 mm piping systems,Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS t Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe.When tightened,the assembly • compresses the gasket onto the OD of the pipe.The Style 922 Outlet-T is UL/FM rated up to 300 psi/2068 kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. • Style 922 is suitable for use on standard,lightwall,Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536,grade 65-45-12.Ductile iron conforming to ASTM A-395,grade 65-45-15,is available upon special request. Gasket: • Grade"E"EPDM-Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc.and Approved by Factory Mutual Research for wet and dry(oil free air)sprinkler services up to the rated working pressure using the Grade"E"Type A Gasket System. Bolts/Nuts:Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: • Orange enamel(North America, Latin America,Asia Pacific) • Red enamel(Europe) JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com �Ot'aUI1C VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. REV G 10.52_1 IPS CARBON STEEL PIPE- HOLE CUT PRODUCTS 10.52 iY STYLE 922 DIMENSIONS Nominal Size Hoie Approx. inches/mm Diameter Dimensions-inches/millimeters Weight Each ....; ..,�.. . Run X Branch +0,06/+1.5 Y Z-{ FPT1 0.40/-0.0 ( T` Y Y Z lbs/kg 11/4 1 1 3/16 1.30 1.83 1.10 3.87 2.56 1.0 V ��� r 32 X 15 30.2 33.0 46 5 27.9 98.3 65 0 0.45 1^� T V., 13/16 1.28 183 1.10 3.87 2.56 11 ■ I. 1��' 20 30.2 32.5 46 5 27.9 98.3 65.0 0.50 • r• �.� W ill 1 1 3/16 1.52 218 1.10 3 87 2.56 1.2 • ��/�/ (V�) 25 Y.. 30.2 38.6 55.4 27.9 983 65.0 054..... 1 Vz 1/2 1 3/16 1.42 1.95 1.22 4.08 2.56 1.2 40 X 15 30.2 36.1 49.5 31.0 , 103.6 65.0 0.54 Ota . 13/16 1.40 195 1.22 4.08 2.56 1.2 20 30.2 35.6 49.5 31.0 103.6 65.0 0.54 1 I 13/16 1.64 2.30 1.22 4.08 2.56 1.3 25 j 30.2 41.7 58.4 31.0 103.6 65.0 0.59 2 Yx 1 3/16 1.66 2.19 1.46 4.60 2.56 1.3 50 X 15 30.2 42.2 55.6 37.1 116.8 65.0 0.59 314 1 3/16 1.64 2.19 1.46 4.60 2.56 1.4 20 30.2 41.7 55.6 37.1 116.8 65.0 0.64 1 13/16 1.88 2.54 1.46 4.60 2.56 1.5 25 j 30.2 47.8 64.5 37.1 116.8 65.0 0.68 21 h 13/16 1.91 2.44 1.71 5.40 2.56 1.6 65 X 15 30.2 48.5 62.0 43.4 137.2 65.0 0.73 3/4 ) 13/16 189 2.44 1.71 5.40 2.56 16 20 30.2 48.0 62.0 43.4 137.2 65.0 0.73 1 1.3/16 2.13 2 79 1.71 5.40 2.56 1.6 25 30.2 54.1 70.9 43.4 137.2 65.0 0.73 76.1 mm X 1/21 3/16 1.91 2 44 1.71 5 50 2.56 1.6 15 30.2 48.5 62.0 43.4 139.7 65.0 0.73 314 1 1 3/16 1.89 2.44 1.71 5.50 2.56 1.6 20 30.2 48.0 62.0 43.4 139.7 65.0 0.73 1 1 3/16 2.13 2.79 1.71 5.50 2.56 1.7._.._... 25 30.2 54.1 70.9 43.4 139.7 65.0 0.80 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT(optional) male pipe threads only.Use of male threaded products with special features,such as probes,dry pen- dent sprinklers,etc.,should be verified as suitable for use with this Victaulic product.Failure to verify suitability in advance may result in assembly problems or leakage. *Center of run to engaged pipe end for NPT threads(dimensions are approximate). www.victaulic.com aCtaUi1C VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.®2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 10.52 2 REVG IPS CARBON STEEL PIPE- HOLE CUT PRODUCTS 10.52 Outlet-:.... STYLE 922 PERFORMANCE Equivalent Length of 1 inch Schedule 40 Steel Pipe(per UL Run Size x Outlet Size 213,Section 16)(C=120)".FT Inches/mm Feet/meters • 11/4 x 1 8.5 32 25 i_ 2.6 1' X 1 8.5 40 25 2.6 • 2X 1 8.5 50 252.6 21/2 X 8.5 65 25 2.6 76.1 mm X 1 8.5 25 2.6 *Hazen-Williams coefficient of friction is 120 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. iCtauluL'� REV_G 10.52_3 IPS;ARKIN, - • STYLE 922 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing.Handbooks are included with each shipment of Victaulic products for complete installation and assembly data,and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. For complete contact information,visit www.victaulic.com 10.52 3355 REV G UPDATED 12/2009 ictaul.c VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.®2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 10.52 VERTICAL MOUNT SAMMYS® SAMMYS° for Steel Installs VERTICALLY into the bottom of steel structures easily and quickly! 1Y_ AIIIIIWAWW� —r n� •Made with Teks®self-drilling fasteners- rap.r 0d no pre drilling required. •Install into steel range from 22 gauge—1/2"thicknesses. . r - - •Saves time from traditional methods. cr •Reduces installation cost. '1 •Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Load - IES 1/4" 8024957 DSTR 100* 1/4-20 x 1"TEKS 3 1510(20 ga.) 036"-20 ga 3/16" 25 125 7 1/4" 8025957 DST 100 1/4-14 x 1"TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 1/4" 8026957 DST 150 1/4-14 x 1-1/2"TEKS 3 970(16 ga.) 4'y. x.036"-20 ga 3/16" 25 125 1/4" 8027957 DST 200 1/4-14 x 2"TEKS 3 446 (20 ga.) 036"-20 ga 3116" 25 125 114" 8030957 TEK 500 12-24 x1-1/2"TEKS 5 3125(3/16") '> °'.187"-3/16" 1/2" 25 125 Q„Q 3/8" 8038957 DSTR 1* 114-20 x 1"TEKS 3 1510 (20 ga.) 1500 1475 .036"-20 ga 3/16" 25 125 — �•`� 3/8" 8037957 DSTR 1-1/2* 12-24 x1-1/2"TEKS 5 1510(3/16") 1500 x;060"-16 ga. 1/2" 25 125 Q 0 3/8" 8039957 DSTR 516* 5/16-18 x 1-1/4 TEKS 3 2200 (20 ga.) 1500 1475 .036%20 ga 1/8" 25 125 3/8" 8040957 DST 10 114-14 x 1"TEKS 3 446(20 ga) t"4� 3/16" 25 125 #14 Black 970(16 gal Nut Driver 446 (20 ga970 1 .) Part#8113910 3/8" 8077925 DST 10-SS 1/4-14 x 1"TEKS 3 ( 6 ga) .036"-20 ga 3/16" 25 125 446 20 a 3/8" 8041957 DST 15 114-14 x t-112"TEKS 3 970(16 ga j " '` .036"-20 ga 3/16" 25 125 3/8" 8078925 DST 15-SS 1/4-14 x 1-1/2"TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 trta-_:;.,. 970 (16 ga.) 3/8" 8042957 DST 20 1/4-14 x 2 TEKS"3 "446(20 ga) .036-20 ga 3/16" 25 125 970(16 ga.) ,,,,,,,,x„,,,,,: itgv-....-: ,--., - 3/8" 8043957 DST 25 1/4-14 x 2-1/2"TEKS 3 446 (20 ga.) 036"-20 ga 3/16" 25 125 970 (16 ga.) 3/8" 8044957 DST 30 1/4-14 x 3"TEKS 3 446(16 ga} ' .036"-20 ga 3/16" 25 125 :a ,Q Q 3/8" 8045957 DST 516 5/16-18 x 1-1/4"TEKS 3 1500 (3/16") 1500 1475 .12Y-1/8" 1/8" 25 125 Q 3/8" 8046957 TEK 50 12-24 x1-1/2"TEKS 5 3125(3/161,i41.,4.-:-,,,-,,1%, 1475 .187"-3/16" 1/2" 25 125 1/2" 8031925 DST 2.0 1/4-14 x 2"TEKS 3 446 (20 ga.) .188"-3/16" 1/4" 25 125 970 (16 ga.) 1/2" 8033925 DSTR 1.0* 1/4-20 x 1"TEKS 3 1510(20 ga) .036"-20 ga 3/16" 25 125 1/2" 8034925 DSTR 5.16* 5/16-18 x 1-1/4"TEKS 3 2220 (20 ga.) .036"-20 ga 1/8" 25 125 r — ___ ,,,e..,,_ - , 1/2" 8035925 DST 5.16 5/16-18 x 1-1/4"TEKS 3 1500(3/16) '.r .12F-1/8" 1/8' 25 125 _ _#14 SW Red -" 1/2" 8036925 TEK 5.0 12-24 x 1-1/2"TEKS 5 3125 (3/16") 187"-3116" 1!2" 25 125 Nut Driver Includes retaining nut , Part#8114910 SAMMY Swivel Head®for Steel installs VERTICALLY and swivels up to 17° in yeel st-,.- •Eliminates distortion of threaded rod in •Installs into angled Z-Purlin;Allows sloped roof applications. threaded rod to hang plumb. '---,—.04.,._ . \ •Accommodates 3-1/2 x 12 pitch. •Allows 17°deflection from vertical. ,-,--_,,,,,.u..,--.„-:-....... -4! 3/8" 8137957 SH-DSTR 1* 114-20 x 1" 3220(3/161 1500 1475 .035" 3/16" 25 125 } .. x" *Includes retaining nut (Does not comply with ROHS requirements) #14 Black £ Nut Driver -_- R'vcc . The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes into Part#8113910 contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. For the most up to date information.visit www.sammysuperscrew.com 6 0 Ilk €g) I "• SAMMYS' HORIZONTAL MOUNT SIDEWINDERS° for Steel _ a �� _ zL - Prom,-H-, t,xss no •Made with Teks®self-drilling fasteners nopre-drilling required. ` ' required 1 •Install into steel range from 22 gauge-1/2"thicknesses. ww ! •Saves time from traditional methods. 1 •Reduces installation cost. '0703i i re''"`'''111 am : ( x •Quick to install using the Sammy Nut Driver with an 18V " its"C 1 cordless drill/driver. _JMTMWf4tKPA. 7:147r47Tltttti~Attttgtftgkg'iti4,14t;ZiSkff :'?'6ir:'44 :4—tii 1/4" 8047957 SWD 100 1/4-14 x 1"TEKS 3 1477(16 ga.) .060"-16 ga 3/1;,,,,14, :;-•,),,t4,125 1/4" 8049957 SWDR 100* 1/4-20 x 1"TEKS 3 1900 (20 ga.) .036"-20 ga 3/16" 25 125 3/8" 8050957 SWD 10 1/4-14 x 1"TEKS 3 1477(16 ga.) .060"-16 ga 3 '125 3/8" 8080925 SWD 10-SS 1/4-14 x 1"TEKS 3 1477 (16 ga.) .06V-16 ga 3/16" 25 125K 3/8" 8051957 SWD15 1/4.14x1-1/2"TEKS 3 1477(16 ga,) .060"-16ga 3E1� L" ';1,125 tiQ.4i. 3/8" 8081925 SWD 15-SS 114-14 x 1-1/2"TEKS 3 1477 (16 ga.) .06(r-16 ga 3/16" 25 125 ;w; 3/8" 8052957 SWD 20 1/4-14 x 2"TEKS 3 1477(16 ga.) .060"-16 ga _j- X25 3/8" 8053957 SWD 516 5/16-18 x 1-1/4"TEKS 3 2480 (20 ga.) .036"-20 ga 1/8" 25 125 f #14 SW 31.<> 3/8" 8055957 SWDR 1* 1/4-20 x 1"TEKS 3 1900(20 gad 1500 1475 g %` Red 036"-20 a 314 25 =;425 Nut Driver 1 Q 318" 8054957 SWDR 1-1/2* 12-24 x 1-1/2"TEKS 5 2375 (3/16") 1500 1475 .18T-3/16" 1/2" 25 125 Part#8114910 Et.d 3/8" 8056957 SWDR 516" 5/16-18x1-1/4"TEKS3 2480(20ga.) 1500 1475 .036"-20ga 1/8" 25 el25 3/8" 8057957 SWT 15 12-24 x 1-1/2"TEKS 5 2375(3/16") .187"-3/16" 1/2" 25 125 a *Includes retaining nut Performance Data-Steel r r .max Gauge No. 26 24 22 20 18 16 14 12 3/16" 1/4" Nominal Decimal Equivalent .018 .024 .030 .036 .048 .060 .075 .105 .188 .250 ' E2-72717tel" }€ v r. Fastener Steel Gauge(lbs.) average •s.c.ma e Model Dia. m 20 mmm®mm Fastener Thickness DST mm 446 613 970 mm 3190 - Model Dia. mm .092 m® DST 516 mmgsim 1209 ®m-- DST 10 mm 1265 - 2750 - :-'.Viiap TEK 50 mm-DDD® 3270 D SWD 10 mm- 1120 - 1420 ife"...triAA-f DSTR 1.1/2" mm----- 3270 m DSTR 1" Elm 1510 ------ DSTR 516 mm 2200 ------ ,,5.--ps,,,,,,,, Fastener Steel Gauge(lbs.) Model Dia CI 20 Eimm®ciEl 1;;;14:1i::r:11::::::::;.; SWD mm--®---- SWDR 1.1/2" mmm------ SWDR 1" mm 1900 -- 1900 --- SWDR 516 mm 2480 -- 2480 --- SPECIAL NUT DRA AR 44-4,1 The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes into 1, contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. 7 To find a distributor near you,call 800-BUILDEX SAMMY X-PRESS® S' dg -- Sammy X-Press® f,..t _ 1 1 Iiiii 1 i -_ •The SammyX-Press expands to provide •Installs in seconds,saving time& (XP) direct vertical attachment in: installation costs. iiiim*iiitisiiiiiiiiiiiiiiiiiiPatenNo :=-:- -Metal Deck(22-16 gauge) 6,935,821 F --- ,a�. -Z-Purlin(18-16 gauge) •Use in applications where access to the back of the installed fastener is •The Sammy X-Press Swivel allows you prohibited.ie.metal roof deck,tubular to hang plumb in extreme roof pitches: steel,or vapor barrier fabric. (SWXP) -89°in Z-Purlin -45°in metal deck for 12/12 pitch •Less jobsite material needed. - Patent Pending for I •The SammyX-Press Sidewinder expands •No retaining nut required. --------- - ______ (SXP) q t4 — x- ' �` to provide horizontal 3116 stetel attachment in: tubular •Provides design flexibility. gaP 9 Y .:.::::„.....„...„:„.„,„:.,,,,,,.......,„_ „„., or steel. Patent Pending t` 1` 1'i roof pitches -""111'''''" ,..,,___:.........___..,........„,,,........,,,,.......i..............,...,.....„,„„:„.„-„,..,,,,,..„„„T.....,,s1 ...:;:i,„:„:„.„....„,,,..,,,,............,p„,a,...,,,,..i.........,,,,„.,,.::,,,,,,,„„..:,..,.....„,,..„,„,„„,,„....,,_,.„„„„„5,J,„,„:„., „:„ „,,„_.:_.,.,:,,.,„.._„...;5,#_, __..„.„...,,,:....,,,,,...,_,....,..."",.......,,,,....p....i.....„,,,,"__„_,::,.,..., ......„,_ _. a I"""ritio VERTICAL MOUNT iiimis 20411.34 1/4" 8181922 XP 200 X-Press 200 1146(22 ga) 185(Luminaire) .027" .125" 25 125 Metal Deck " 250(Luminaire) .056" 850(2W Pipe) '-: r' 940(2'Pipe) .027"lippri 185(Luminaire) Q.0 3/8" 8150922 XP 20 X-Press 20 1146(22 ga) 1475(4"Pipe) .02T 125" 25 125 Metal Deck 250(Luminaire) .056° 283(Conduit&Cable) 1500(4"Pipe) .060' Q.:'' 3/8" 8153922 XP 35 X-Press 35 1783(16 ga) 85(Luminaire) 940 (2"Pipe) 105" 125" 25 125 Purlin 250(Luminaire) 1475(4"Pipe) .027" .- 416(Conduit&Cable) .056" 750(2°Pipe) 1061(22 ga Vertical) 170 vertical(Luminaire) 3/8" 8294922 SXP 20 Swivel X-Press 20 829(45°Off Vertical) 80 @ 45°(Luminaire) 635(2'Pipe) .027" .125° 25 1- .Metal Deck 283 vertical(Conduit&Cable) rearitliptii 233 @ 45°(Conduit&Cable) 1500(4"Pipe) 1675(16 ga Vertical) 250 vertical(Luminaire) i-mivimakkaziaisakiitkViiik3/8" 8295922 SXP 35 Swivel X-Press 35 1558(89°Off Vertical) 80 @ 90°(Luminaire) 635(2"Pipe) .060" .125" 25 125 Purlin 500 vertical(Conduit&Cable) „, = 333 @ 89°(Conduit&Cable) ='"> '- — Metal Deck Pre-Pour Structural Concrete@ 3000 psi (Pre-Pour) Q" 3/8" 8150922 XP 20 Sammy X-Press 20 1146(22 ga) 850(2%Pipe) 25 125 Metal Deck link- -—00918511 Post-Pour Range II LWC<_35 PCF(Ibs/ft'} (Post-Pour) HORIZONTAL MOUNT 1250(314"Pipe) Plintalliall C?, 3/8" 8293957 SWXP 35 Sidewinder X-Press 35 1798(16 ga) 80(Luminaire) .060" .125" 25 125 Purlin 416(Conduit&Cable) igiallaittalliiiiii Pre-Pour Structural Concrete @ 3000 psi Post-Pour Range II LWC<35 PCF(lbs/C') Sammy X-Press It® INSTALLATION TOOL !!!!!!.04'2°' _ . _,,,,:::.„„_,_, UXPIT.„„.„,.........„..„ „,....„-T4 - . _....., -. - - 4 __...,....................,......_.......,: _ 1 - -- -4e- - - - a � Patent Pending lis _ _ ? 11,1 - - tri--- monraai 8194910 UXP)T* Universal X-Press It Tool 1 -- — .: lint,libillignIk 8195910 RXPIT Retro Socket for 8151910 1 8152910 XPDB 25/64"Drill Bit 1 To watch a video demonstration of the Sammy X-Press,visithdp://wwwsammysuperscrewcom/sammyxpress.htm "Tool Includes:Sleeve,Bit Receiver,Hex Wrench,and 25/64"Drill Bit. _,. For the most up to date information,visit www.sammysuperscrew.com 8 HS ..,, Threaded Accessories B3205 - Threaded Rod (right-hand threads - both ends) (TOLCO Fig.103) B3205L - Threaded Rod (right& left hand threads) TI Specify Length K11111�1111� Size Range: 3/8"-16 thru 3"-4 rod •L• Material: Steel Function: Recommended for use as a hanger support in hanger assemblies. TL 111 Rod is threaded on both ends with right hand threads of the length shown.Alsohll����� A available with left and right hand threads-specify Fig. B3205L when ordering. Thread Size Maximum Temperature: 750°F(399°C) • Finish: Plain. Contact B-Line for alternative finishes and materials. Order By: Part number, rod size, length and finish Standard Design Load Thread Size Thread Length TL 650°F(343°C) 750°F(399°C) Part No. A in. (mm) Lbs. (kN) Lbs. (kN) 83205-3/8x'L' 3/8°-16 21/2" (63.5) 730 (3.25) 572 (2.54) B3205-112 x'L' 1/2"-13 21/2° (63.5) 1350 (6.00) 1057 (4.70) 83205-5/8x'L' 5/8"-11 21/2" (63.5) 2160 (9.61) 1692 (7.52) B3205-3/4 x'1' 3/4"-10 3" (76.2) 3230 (14.37) 2530 (11.25) B3205-7/8 x'L' 7/8"-9 31/2" (88.9) 4480 (19.93) 3508 (15.60) B3205-1 x'L' 1"-8 4" (101.6) 5900 (26.24) 4620 (20.55) 83205-11/8x'L' 11/8"-7 41/2" (114.3) 7450 (33.14) 5830 (25.93) B3205-11/4 x'L' 11/4"-7 5° (127.0) 9500 (42.25) 7440 (33.09) B3205-11/2 x'L' 11/2"-6 6" (152.4) 13800 (61.38) 10807 (48.07) B3205-13/4 x'L' 13/4"-5 7" (177.8) 18600 (82.73) 14566 (64.79) B3205-2 x'L' 2"-41/2 8" (203.2) 24600 (109.42) 19625 (87.29) B3205-21/4 x11.' 21/4".41/2 9" (228.6) 32300 (143.67) 25295 (112.51) B3205-2112 x'L' 21/2"-4 10" (254.0) 39800 (177.03) 31169 (138.64) B3205-23/4 x11.' 23/4"-4 11" (279.4) 49400 (219.73) 38687 (172.08) B3205-3 x'L' 3"-4 12" (304.8) 60100 (267.32) 47066 (209.35) ATR -All Threaded Rod 120" (3.05m) Lengths (TOLCO Fig.100) Fig. 99 -All Threaded Rod Cut To Length Size Range: 3/8"-16 thru 11/2"-6 rod in 120"(3.05m)lengths or cut to length5� �1' Material: Steel0 Maximum Temperature: 750°F(399°C) Finish: Plain. Contact B-Line for alternative finishes and materials. s Order By: Part number, rod diameter and finish Q' Part No.-Size x Length Threads Recommended Load Approx.WtJ100 Ft. ATR Fig.99 Per Inch Lbs. (kN) Lbs. (kg) ATR 1/4"X 120 99-1/4"x length 20 240 (1.07) 12 (5.44) ATR 3/8"x 120 99-3/8"x length 16 730 (3.24) 29 (13.15) ATR 1/2"x 120 99-1/2"x length 13 1350 (6.00) 53 (24.04) ATR s/8"x 120 99-5/8"x length 11 2160 (9.60) 89 (40.37) ATR 3/4"X 120 99-3/4"x length 10 3230 (14.37) 123 (55.79) ATR 718"x 120 99-7/8"x length 9 4480 (19.93) 170 (77.11) ATR 1"x120 99-1"x length 8 5900 (26.24) 225 (102.06) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. ■ B-L ne Pipe Hangers&SupportsRevised4/28/2014 236 by E.A.N Pipe Hangers Fig.200- "Trimline" Adjustable Band Hanger (B-Line Fig.B317ONF) O ' CCI Fig. 200F- "Trimline" Adjustable Band Hanger with Felt Lining (B-Line Fig.B317ONFF) DL 1.18 Fig.200C - "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line Fig.B317ONFC) LISTED Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig. 200 - 1/2" (15mm)thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications y Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. --------.% Features: U ® ,_ ' • (1/2" (15mm)thru 2" (5omm)) Flared edges ease installation for all pipe ,(�� types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily e installed around pipe. A For hanger with non-captured nut order Fig. 2005. ' • (21/2" (65mm)thru 8" (200mm)) Spring tension on nut holds it securely in - / hanger before installation.Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm)thru 8" (200mm)) Fig.200-1/2.200-3/e in the USA(UL) and Canada (cUL)for steel and CPVC plastic pipe and Fig.200-1 to 200-2 Fig.200-21/2 to 200-8 Factory Mutual Engineering Approved (FM) (3/4" (20mm)thru 8" (200mm)). Conforms to Federal Specifications WW-H-171 E &A-A-1192A,Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 &SP-58, Type 10. Maximum Temperature: 650°F(343°C) Finish: Pre Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of FM DS 2-0. . Fig.200 Fig.200C Fig.200F Pipe Size Rod Size A B Approx.Wt./100 Part No. in. (mm) in. (mm) in. (mm) lbs. (kg) 200-1/2 1/2" (15) ' .:---.,-L--.:__ 3/8"-16 ,-,..-->e-51. 31/8" (79.4) 25/8" (66.7) ' !ii11 15.01 200-3/4 3/4" (20) 3/8"-16 31/8" (79.4) 21/2' (63.51 11 (5.0) , 4 200-1 1' (25) --,::,: i,,, 3/e-16 .;; 33/8" (85.71 25/8" (66.7) ' 12 (5.5) 200-11/4 11/4" (32) 3/8"-16 33/4" (94.0) 27/8" 173.0) 13 (5.9) 200-11/2 11/2" (40) , ,, 3/8"-16 h.)` :: 37/8" (98.4) 27/8" 173.0) ; '4 14 (6.4) 200-2/2 / (50) 3/8"-16 41/2" (114.3) 3" (76.3) 15 16.9) 1 1 2" (65) F ss` 3/8" 16 , 55/8 (142.91 41/8" (104.7) '''''*34:1":","27 (12.31 :. 200-3 3" (75) 3/8"-16 57/8" (149.1) 4" (101.6) 29 (13.3) Fig.2008 200-31/2 31/2" (90) .f>; .: 3/8"-16 '';-;;;.:-.--.1' � 73/8" (187.3) 51/4" (133.3) 34 (15.6) 200-4 4" (100) 3/8"-16 73/8" (187.3) 5" (127.0) 35 (16.0) 200-5 5" (125)1-1.K.*: 1/2%13 ,,,;.".91/8" (231.8) 61/4" (158.71 /r " 66 (30.2) 200-6 6" (150) 1/2".13 101/8" (257.2) 63/4" (171.4) 73 (33.4) 200-8 8" (200) . 1/2'-13 '''5;;;;,--13118" (333.4) 83/4" (222.2) A.,"136 (62.3) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line Fire Protection Solutions 21 by EkI.N