Loading...
Permit CITY OF TIGARD BUILDING PERMIT N-1 . COMMUNITY DEVELOPMENT Permit#: BUP2018-00167 and OR 97223 503.718.2439 13125 SW Hall Blvd.,Ti Date Issued: 09/17/2018 1rc ;�rt� s Parcel: 1S135BA00100 Jurisdiction: Tigard Site address: 10125 SW WASHINGTON SQUARE RD Project: Jaguar Land Rover Subdivision: None Lot: None Project Description: New commercial building for auto dealership with service,parking structure and pavilion. Contractor: PERLO CONSTRUCTION LLC Owner: PPR SQUARE TOO LLC 16101 SW 72ND AVE SUITE 200 PO BOX 847 TIGARD, OR 97224 CARLSBAD, CA 92018 PHONE: 503-624-2090 PHONE: FAX: 503-639-4134 Specifics: FEES Description Date Amount Type of Use: COM Class of Work: NEW Type of Const: VA Permit Fee-COM-New Construction 09/17/2018 $82,527.42 Occupancy Grp: Occupancy Load: 984 12%State Surcharge-Building 09/17/2018 $9,903.29 Dwelling Units: 0 Plan Review 05/30/2018 $53,642.82 Stories: 3 Height: 40 ft Wash Co Trans Dev Tax 09/17/2018 $230,988.00 Parks SDC Improvement 09/17/2018 $23,307.00 Bedrooms: Bathrooms: 4 Parks SDC Reimbursement 09/17/2018 $4,207.00 Value: $18,300,000 DC Provision Review,COM New-Bldg 09/17/2018 $194.00 Plan Review-Fire Life Safety 09/17/2018 $33,010.97 Floor Areas: Info Process/Archiving-Lg$2.00(over 09/17/2018 $278.00 11x17) Total Area: 44067 Info Process/Archiving-Sm$0.50(up to 09/17/2018 $375.50 Accessory Strutt: 11x17) Basement: Metro Const.Excise Tax 09/17/2018 $12,000.00 Carport: Additional Plan Review 09/17/2018 $200.00 Additional Plan Review 09/17/2018 $200.00 Covered Porch: Additional Plan Review 09/17/2018 $200.00 Deck. Additional Plan Review 09/17/2018 $200.00 Additional Plan Review 09/17/2018 $200.00 Garage: Additional Plan Review 09/17/2018 $200.00 Mezzanine: Additional Plan Review 09/17/2018 $200.00 Total $479,776.71 Required: Required Items and Reports(Conditions) Fire Sprinkler: Parapet: Fire Alarm: Protected Corridors: Smoke Detectors: Manual Pull Stations: Accessible Parking: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy� of the rules /�ordidirect questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: GF��` �e�?� �,� iiLs Permittee Signature:Call 503.639.4175 by 7:00 a.m.for the next available inspecction date. /� ` This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. • i 114 City of Tigard • COMMUNITY DEVELOPMENT DEPARTMENT Accessibility: Barrier Removal Improvement Plan -- Commercial & Multi-Family - Additions or Alterations TIG n R lD 13125 SW Hall Blvd. • Tigard, Oregon 97223 • 503.718.2439 • www.tiaard-or.gov REQUIREMENT: OREGON REVISED STATUTE (ORS)447.241. (1) Every project for renovation,alteration or modification to affected buildings and related facilities shall be made to insure that the path of travel to the altered area and the restroom, telephones and drinking fountains are readily accessible to individuals with disabilities unless such alterations are disproportionate to the overall alterations in terms of cost and scope. (2) Alterations made to the path of travel to an altered area may be deemed disproportionate to the overall alteration when the cost exceeds twenty-five percent(25%). VALUATION: Total of all renovation,alteration or modification being done, excluding painting and wallpapering: [1] $ MULTIPLIER (25%barrier removal requirement): x 25 TOTAL BUDGET FOR BARRIER REMOVAL: [2] $ ELEMENTS: In choosing which accessible elements to provide under this section,priority shall be given to those elements that will provide the greatest access. Elements shall be provided in the following order: (a) Parking $ (b) An accessible entrance: $ (c) An accessible route to the altered area: $ (d) At least one accessible restroom for each sex or a single unisex restroom: $ (e) Accessible telephones: $ (f) Accessible drinking fountains:and, $ (g) When possible,additional accessible elements such as storage and alarms: $ TOTAL(shall equal line [2] of Valuation Computation): $ l:\Building\I'cm its\BUI'COM_Pemuulpp.doc Kcv.12/18/2014 City of Tigard • COMMUNITY DEVELOPMENT DEPARTMENT Plan Submittal Requirements Commercial & Multi-Family - New, Additions or Alterations 13125 ard,SW Hall Blvd. • Ti Ore 'on 97223 • 503.718.2439- ard- r. v I. SITE PLAN (3) copies - fully dimensional, drawn to scale and labeled with: A. j map& tax Iot # xQ project name 0 site address 0 zoning 0 applicant name suite number pP phone® number B. North arrow. C. Scale (architectural or engineering only). D. Street names. E. Setbacks. F. Parking, including disabled access. G. Finished floor elevations. 2. EROSION CONTROL PLANS AND DETAILS. Previously submitted 3. BUILDING PLANS: See the "Plan Submittal Requirement Matrix" for the number of plans required based on submittal type (no redlines or tape-ons accepted). All tails listed below hall he inco orated into the lan A. Scale (architectural or engineering only). B. Foundation plan. C. Floor plan(s). D. Cross sections. E. Reflective ceiling plan. F. Seismic bracing detail for suspended ceiling. G. Roof plan. H. Exterior elevations. I. Structural calculations,plans, details and specifications. J. Accessibility barrier removal worksheet. K. Deposit- based on valuation of project. 4. ADDITIONAL INFORMATION AS FOLLOWS: A. Fire Department Building Survey with (1) additional full set of architecture drawings. I Budd w,'\hermits\HUN_Ca)M_I'crrrr��ltip A14% 12 18'21 I.1 City of Tigard • COMMUNITY DEVELOPMENT DEPARTMENT lig Q ' Plan Submittal Requirements Matrix - Commercial & Multi-Family - New, Additions or Alterations T l C,A rt u 13125 SW Hall Blvd. • Tigard, Oregon 97223 • 503.7 18.2439 • www.tieard-or.eov Type of Submittal # of Plans (Includes new,additions and alterations.) Required at Submittal Demolition Permit 2 (site plan is required showing location and square footage of all buildings to be demolished,erosion control plan and tree protection,if applicable Site Work 3 (must include location of all accessible parking; Plumbing (site utilities) 2 Building 3 Fire Protection System 3 Mechanical 2 Plumbing(building fixtures) 2 Electrical 2 Solar Photovoltaic 2 (Requires check list for prescnpnvc installation. If not prescriptive installation,engineering is required.) Plan review is dependent upon submittal of a completed application and plans. After plan review approval, the Plans Examiner will contact the applicant to request additional sets of plans for distribution purposes (for contractor, City of Tigard,Washington County, and Tualatin Valley Fire& Rescue), if applicable. 1 liuilciing',l'cmw.,\iitJl'_(a7\i_1'urntAppdoc itiN 12 r'18 2014 Agnes Lindor From: Agnes Lindor Sent: Thursday, June 21, 2018 7:05 AM To: 'gene@ mdg pc.com' Cc: 4#Building Permit Technicians; Schuyler Warren; Mike White Subject: B U P2O 18-001 67 Attachments: 6-21-18 Jaguar conditions.pdf Good morning Gene- You building permit for Jaguar Land Rover has been approved but will not be released until all necessary planning and engineering conditions are met. I have attached the conditions status report showing which conditions are still pending. Please contact Schuyler Warren regarding planning conditions and Mike White regarding engineering conditions. Thanks, Agnes Lindor I Associate Planner City of Tigard I Community Development 13125 SW Hall Boulevard Tigard, Oregon 97223 Phone: 503.718.2429 Email: AgnesL@tigard-or.gov 1 MILDREN DESIGN GROUP,RC. .r liNtecture Sp.>cr. Nanning RECEIVED LETTER OF TRANSMITTAL SEP 2018 CITY OF TIGARD To: City of Tigard BUILDING' DI IIatec September 4,2018 13125 SW Flail Blvd. ����d Tigard,OR 97223 Attention: Tom Hochstatter Copy to: Project Name: JLR Washington Square Project Number: 116139 Attached items: Description: 2 sets Updated/revised Showroom, Pavilion, Service Center Building and Carwash Structural Calculation Set as prepared by T.M. Rippey Consulting Engineers 2 sets Updated/Revised Structural Plans and Details Set as prepared by T.M. Rippey Consulting Engineers X For your use _ For approval For your review _ As requested Remarks: Signed: Gene Mildren Mailed _To be picked up _X_Delivered via MDG P:\116139 Land Rover-Jaguar Washington Square\wp\tr-CoT-th-l.wpd 7650 SW 144443 U,,,e!aAi Street,Su1tt^120 i t,trd,,O4 on 97223 502 244 0552 Fax 503 244 0417 City of Tigard 111‘ ® COMMUNITY DEVELOPMENT DEPARTMENT III TIGARD Building Permit Review — Commercial - With Land Use (V, Building Permit #: „Lj ptpc>2.p/, — 40/4 7 Site Address: /0/05 3o) -4, ,C,, v��t,; /Suite/Bldg#: Project Name: Taq ua.- Lard Rover (Name o ommercial business occupying the space. If vacant,enter Spec Space.) Planning Review > )) / / Proposal: Aecc� �,,s4rt.� ;a,, c-J 6it,7�Grr�c)6,re clewh- ..S1,G `Verify site address/suite# exists and active in permit system. "LI River Terrace Neighborhood: ❑ Yes E2-No ,2 Land Use Case#: dao 11-00605- E 06©S❑ Plans Match Approved Land Use: 'Site Plan Landscape Plan ❑ Other: ITUrban Forestry Plan „,Elevation Plan .$Building Height: Maximum Height _ Actual Height Conditions Met: El Prior to Submittal g'i4rior to Permit Issuance ,;i'Business License: � Exists:� 111 Yes ❑�io,applicant notified to obtain business license -IBJ Public Facilities Improvement(PFI) Permit: Required: -Er es,ap licant was notified/ El Applied For::, es El No, stop intake Notes: Cu n U, .`c, /1_5 'AD be rye/ �/' �''^ 4) i 5-.56,1°,--7 c e Approved by Planning: C62------- Date: .5 ge//s Revisions (after Building Submittal only) Reuiewer Date Revision 1: ^ .pproved El Not Approved Revision 2: ❑ Approved El Not Approved - Revision 3: ❑ Approved El Not Approved Building Permit Submittal Original Submittal Date: .J/3 /,e' Site Plans: # Building Plans: # j Building Permit#: 11--Enter building permit#above. Workflow Routing: li'Planning e7'Engineering Et-Permit Coordinator Building Workflow Sign-off: ®' Sign-off for Planning(include notes from planning review) Route Application Documents: 113uflditig: original permit application, site plans,building plans,engineer and beam calculations and trust details,if applicable,etc. Notes: �r By Permit Technician: 'l,/,), '(✓-2,l-t-2.` Date: --573 OP I:\Building\Forms\BldgPermitRvw COM_WithLandUse 060116.docx Engineering Review ❑ Slope at building pad: ❑ PFI Permit#: ❑ Conditions "Met"prior to issuance of building permit ❑ Easements (encroachments)per engineering conditions of approval and plat(not typical on SDR/CUP) .�-Water Quality/Quantity Facility: Assess Water Quality Fee in-lieu: ❑ Yes .B' No Assess Water Quantity Fee in-lieu: ❑ Yes ['No LIDA Facility on lot: ❑ Yes No O NOT Approved by Engineering: Date Notes: &MIT I 6_, �z P6 ik--;/ -j Zj "Plc-4-f-- 4 ~,IZ ) 6S - C 4 Approved by Engineering: j1i 01_ ` Date: 4 6/t 8 Revisions (after Building Submittal only) Reviewer Date Revision 1: ❑ Approved ❑ Not Approved Revision 2: 0 Approved ❑ Not Approved Revision 3: 0 Approved ❑ Not Approved Permit Coordinator Review ( )onditions "Met"prior to issuance of building permit E t .Approved,NOT Released: Date: (.0I 2A 1 1 s Notes: ('eir1, 1, rla}- Y' . iflif,,Atzd atip pl.t_co.,-/-- Revisions (after Building Submittal only) Revision Notice 1: Date Sent to Applicant: Revision Notice 2: Date Sent to Applicant: Revision Notice 3: Date Sent to Applicant: XSDC Fees Entered: Wash Co Trans Dev Tax: , Yes ❑ N/A Tigard Trans SDC: ❑ Yes J N/A Parks SDC: ,Yes ❑ N/A OK to Issue Permit Approved by Permit Coordinator: ii( AeddA,, tie..-44— ate: / Zr----- I: �I:\Building\Forms\BldgPermitRvw_COM_W ithLandUse_070915.docx FOR OFFICE USE ONLY—SITE ADDRESS: This form is recognized by most building departments in the Tri-County area for transmitting information. Please complete this form when submitting information for plan review responses and revisions. This form and the information it provides helps the review process and response to your project. City of Tigard • COMMUNITY DEVELOPMENT DEPARTMENT 11111 Transmitt l Letter etter 1 t, \k t) 13125 SW Hall Blvd. • Tigard, Oregon 97223 • 503.718.2439 • www.tigard-or.gov TO: jc DATE RECEIVED: DEPT: BUILDING DIVISION RECEIVED SEP b 2018 FROM: 6e.,/ /27 /ire") CITY OF i IGARD COMPANY: i {y / AT/ � - BUILDING DIVISION PHONE: C57/3)Pyr'l-0545`a. By:.8l RE: vfv25— M4J;4)W//1� �v c� Ofreigeir)r-e967 Site Address) � 6r((yyt�asubdivision name and lot number) ATTACHED ARE THE FOLLOWING ITEMS: Copies: Description; Copies: Description: Additional set(s) of plans. Revisions: Cross section(s) and details. Wall bracing and/or lateral analysis. Floor/roof framing. Basement and retaining walls. Beam calculations. Engineer's calculations. Other(explain): REMARKS: s/_- L...i .�. ' _ A. w /° ? #1A,e ✓ti 64JGl. FOR OFFICE USE ONLY Routed to Permit Technician: Date:- 1 ! Initials: 7 j Fees Due: ❑Yes PA T Js----. Fee Description: Amount Due: Special Instructions: Reprint Permit(per PE): [] Yes No 0Done Applicant Notified Date: fro/1 Initials: I:\Building\Forms\TransmittalLetter-Revisions.doc 05/25/2012 FOR OFFICE USE ONLY-SITE ADDRESS: This form is recognized by most building departments in the Tri-County area for transmitting information. Please complete this form when submitting information for plan review responses and revisions. This form and the information it provides helps the review process and response to your project. City of Tigard • COMMUNITY DEVELOPMENT DEPARTMENT It Transmittal Letter , \ / TIGARD 13125 SW Hall Blvd. • Tigard, Oregon 97223 • 503.718.2439 • www.tigard-or.gov . TO: `SAA 14-tx, S- ;-r>r DATE RECEIVED: /-1 DEPT: BUILDING DIVISION lECEI V a N.4 JUN 10 119 FROM: 1-t-Pc-iz7.iSgJ ST7c--41 CITY •' TIGARD COMPANY: i E 1-o c--o"./sTe_vc,-n�� BUILR G DIVISION PHONE: cad . 2-1-o. 912 - By:F2 /. + V ` �' 10/Z-5 Sv-i Wks N',4 C>T"q'c./ `.>G62.. "Z', - 2-01 E3 - C9 o I i,"4- (Site Address) (Permit Number) (Project name or subdivision name and lot number) \ I k ATTACHED ARE THE FOLLOWING ITEMS: `' Copies: Description: C6. es: Description: Additional set(s) of plans. Revisions: Cross section(s) and details. -' Wall bracing and/or lateral analysis. �� Floor/roof framing. \ ,° Basement and retaining walls. Beam calculations. �" Engineer's calculations. ; Other(explain): >cj , 5✓grvi 1-��et-t_ REMARKS: STD?-0F Z 46 .`15��r✓1 51tU' s�2i�-vii�/(�-S 4.-- ev L, . C:PCL L 5. - aD(' FOR OFFICE USE ONLY Routed to Permit Technician: Date: Initials: Fees Du-e-1-------11 Y/ No Fee Description: Amount Due: Pi G-. / e.+, 47-,s..j a Acca ,=hm e...ss4.,) $ P c i a. A s ----- $ $ Special Instructions: Reprint Permit (per PE): I I Yes No I I Done Applicant Notified: a . Date: (o jiVt"s Initials: y/ 1:\Bui14i1 Forms\TransmittalLetter-Revisions.doc 05/25/2012 MILDREN DESIGN GROUP,P.C. Er4dtti .Space Planning OCT 2 2019 LETTER OF TRANSMITTAL GUY OF BUILDING To: City of Tigard Date: October 2, 2019 13125 SW Hall Blvd. Tigard,OR 97223 Attention: Tom Hochstatter Copy to: Project Name: JLR Washington Square Project Number: 116139 Attached items: Description: 15V It. 16e FV-14CC 1 each Half size set of current drawings(Rev 12). ..k tqt -29 -001(07 X For your use For approval For your review As requested Remarks: Signed: Curt Trolan Mailed To be picked up X Delivered via MDG _ -- Pi\116139 Land Rover-Jaguar Washington Square wp\tr-CoT th-4 wpd 7650 SW Beveland Street,Suite 120 Tigard,Oregon 97223 503 244 0552 Fax 503 244 0417 FOR OFFICE USE ONLY—SITE ADDRESS: This form is recognized by most building departments in the Tri-County area for transmitting information. Please complete this form when submitting information for plan review responses and revisions. This form and the information it provides helps the review process and response to your project. City of Tigard • COMMUNITY DEVELOPMENT DEPARTMENT 111 Transmittal Letter T 1 G A R D 13125 SW Hall Blvd. • Tigard, Oregon 97223 • 503.718.2439 • www.tigard-or.gov TO: -7 0L DATE RECEIVED: DEPT: BUILDING DIVISION 4r. xWED FROM: C-W OCT 2 2019 COMPANY: (, �ICSN a u e CITY OF I . ? ' PHONE: 3 ZK`� QS- 9"Z- BUILDING DWI, RE: 12-5 S w St(ll,-) T©-) SQ g. ao 13 co I (e,Tl (Site Address) (Permit Number) (Project name or subdivision name and lot number) ATTACHED ARE THE FOLLOWING ITEMS: Copies: Description: Copies: Description: Additional set(s) of plans. ` 2( Revisions: 2-- Cross section(s) and details. Wall bracing and/or lateral analysis. Floor/roof framing. Basement and retaining walls. Beam calculations. Engineer's calculations. Other(explain): REMARKS: V t' kTE U t'LA N S T G©r-TP-kL C,LM..1 Ft c Aro 0 S Ar'. ' f--Z\ S(r^ {'amu- c o..� C )(Z. A.DAt17,DN (A.)Cz:›P-AA,A TT°r-' FOR OFFICE USE ONLY Routed to Permit Technician: Date: )fl — Initials: Fees Due: 11 Yes pu Net, Fee Description: Amount Due` Special Instructions: Reprint Permit(per PE): 111Yes ® No ❑ Don plicant Notified. -- Date: /!y//.1//4 Initials: 4G /fi`r 4P(7v 7l( e4r.s -c/ 45 7Z,6s ) 1I"( "° ' I:\Building\Forms\TransmittalLetter-Revisions_061316.doc fgrit2ol8 /o/25 wig Se? dei perlo SUBMITTAL CONSTRUCTION JAGUAR LAND ROVER OF Subcontractor: KO Custom Fab Inc. PORTLAND Submittal#: 102 Rev#: 0 RECEIVED Specification Section: 05 51 00 MAY p 2019 2 Perlo Job Number: 1368 Date Submitted: 3/26/19 Gt.`,/ OF TIGARD LDING DIVISION Submittal Item: Stair#1 and #2 Shop Dings Please Respond By:4/2/19 PROJECT SITE: PERLO CONSTRUCTION HAS REVIEWED THIS SUBMITTAL DATE 3/26/19 SIGNED Jake Jensen Jaguar Land Rover of Portland 10125 SW Washington Square Road REVIEW BY CONTRACTOR IS UNDERTAKEN SOLELY TO SATISFY ANY OBLIGATIONS OF CONTRACTOR TO OWNER Tigard, Oregon 97223 AND DOES NOT IN ANY WAY RELIEVE SUBCONTRACTOR FROM HIS OBLIGATION FULLY TO PERFORM ALL SUBCONTRACT REQUIREMENTS,NOR SHALL SUCH REVIEW APPROVER: GIVE RISE TO ANY RIGHT OF ACTION OR SUIT IN FAVOR OF SUBCONTRACTOR OR THIRD PERSONS AGAINST CONTRACTOR. REVIEW DOES NOT EXTEND TO Mildren Design Group CONSIDERATION FOR STRUCTURAL INTEGRITY,SAFETY, Attention: Curt Trolan DETAILED COMPLIANCE WITH CONTRACT REQUIREMENTS OR ANY OTHER OBLIGATION OF THE SUBCONTRACTOR. 7650 SW Beveland Street, Suite 120 SUBCONTRACTOR IS FULLY RESPONSIBLE FOR CONFIRMING AND CORRELATING ALL DIMENSIONS; Tigard, Oregon 97223 FABRICATING AND CONSTRUCTION TECHNIQUES; COORDINATING HIS WORK WITH THAT OF ALL OTHER TRADES;AND THE SATISFACTORY PERFORMANCE OF HIS GENERAL CONTRACTOR ENTIRE WORK IN STRICT ACCORDANCE WITH THE CONTRACT DOCUMENTS. Approver's Stamp: Perlo Construction NO EXCEPTION NOTED ❑ MAKE CORRECTIONS NOTED tE Attention: Jake Jensen REJECTED ❑ REVISE AND RESUBMIT ❑ 11450 SW Amu Street THIS REVIEW IS FOR GENERAL CONFORMANCE WITH DESIGN Tualatin, Oregon 97062 CONCEPT ONLY. ANY DEVIATION FROM PLANS OR SPECIFICATIONS NOT CLEARLY NOTED BY THE CONTRACTOR HAS NOT BEEN REVIEWED. REVIEW SHALL NOT CONSTITUTE A COMPLETE CHECK OF ALL DETAILED DIMENSIONS OR COUNT OR SERVE TO RELIEVE THE CONTRACTOR OF CONTRACTUAL RESPONSIBIUTY FOR ANY ERROR No Exception ❑ Make Corrections OR DEVIATION FROM CONTRACT REQUIREMENTS. Rejected ❑ Revise and Resubmit ❑ TM RIPPEY This review is for general conformance with design concept CONSULTING ENGINEERS only. Any deviation from plans or specifications not clearly PORTLAND, OREGON noted by the contractor has not been reviewed. Review shall not constitute a complete check of all detailed DATE 4-4-2019 pY: RNT dimensions or count or serve to relieve the contractor of contractual responsibility for any error or deviation from the contract requirements. Date:04-05-2019 Reviewed by:CLT MILnREN DEsicN GROUP,P.C. SHEETS E3021, 3024 , 3601A OR GCB 189245 LICENSED THROUGHOUT THE WESTERN UNITED STATES AZ ROC 293181 KO KO Custom Fab Inc. PO Box 1343 OR CCB: 196494 Estacada, OR 97023 WA CL#: 18625 SE Bakers Ferry Rd - Boring, OR 97009 KOCUSCF884KW PH: 503-630-7990 -- Fax: 503-630-7888 Transmittal #1111-14 To: AAI Engineering 4875 SW Griffith Drive, Suite 300 Beaverton, OR 97005 STAIR CALLOUTS ARE REVERSED STAIR#1 IS ADJACENT TO GRID P Attn: Chemelle Stark/chemelles@aaieng.com STAIR#2 IS ADJACENT TO GRID M Date: 3/15/19 Project: #1111 -Jaguar-Land Rover STAIRS#1 &#2 TO RECEIVE SP6 FINISH WITH STD GREY PRIMER Items Included: #1111 - IFA #019 Stair#001 & #002 for Engineer Stamp Shops: 3600- 3619 Rev. B Dated 3/13/19. Erection Drawings: E3021 &E3024 Rev. B dated 3/13/19. "For Engineer Stamp" Via email Please review and return no later than 3/22/2019 31,0CTUR4t Thank-You `kVatD PROFF�,� KO Custom Fab, Inc. 4 72666PE Lee Morris Lee@kocustomfab.com OREGOH0t °9 q 41iE l•c'�� EXPIRES: 6/30/20