Loading...
Report (168) C:o©c i U � sv3 c-12 . RECEIVED AUG 7 2018 CITY OF "I i( N1-; :) BUILDING DIVISlop,p Product Data For: River Terrace East Condominiums S.W. Appledale Rd. and S.W. 169th Ave. Tigard, Oregon 97223 Specification Division 21 Fire Sprinkler System GGr4 OFFIGG`#. Jet Fire Protection 1935 Silverton Rd. N.E. Salem, Oregon 97301 ES-A-InBuildingRiser Job Name Contractor Job Location Approval Engineer Contractor's P.O. No. Approval Representative LEAD FREE* Series IBR In-Building Risers Customizable Sizes: 4" — 10" (100 — 250mm) • 9 Building Floor d:o Building perimeter wall CAP TE INCLUDED! O O g O q:: O eac, •�`� W No ,.a 6'x6'standard length o a r (custom lengths from 3'—20'available) ME= Flow Features Series IBR In-Building Risers are used to connect the main fire supply to the building overhead fire system.The fitting passes under the foundation without joints and ex- •Cost savings tends up through the floor. Provided with installation tabs,the unit has a CIPS(Cast •Corrosion resistant stainless steel Iron Pipe Size)coupler for easy connection to the underground supply(AWWA C900 construction, type 304 PVC and Ductile Iron Pipe)and industry standard grooved-end connection(AWWA •Ease of installation and light weight allows C606)on the building side for easy connection to the overhead fire sprinkler system. one person to position and handle the riser The IBR features Lead Free*construction to comply with Lead Free*installation requirements. •Minimal site preparation;joint restraint one- piece construction reduces time and labor; Ames In-Building Risers are precision engineered and manufactured to provide no missing parts, no leaks; easily identifiable exceptional reliability and reduce installation time&labor costs associated with field for approvals assembly. In accordance with NFPA 24,the UL/FM approved In-Building Risers replace numerous fittings, elbows&spools and reduces the possibility of leaks or •Includes Test Cap and Coupler failure in comparison to traditional installation methods and materials. Factory tested •ULJFM approved integrity ensures the highest quality installation.The use of stainless steel significantly •Sizes: available in 4"— 10" (100-250mm) increases the reliability and life of the riser. with various lengths to meet local require- *The wetted surface of this product contacted by consumable water contains less ments than 0.25%of lead by weight. •Designed to meet NFPA 24 •AWWA C900 Inlet/DIP •AWWA C606 Outlet AMES Ames Fire&Waterworks product specifications in U.S.customary units and metric are approximate and are provided for reference only.For precise measure- » = ments,please contact Ames Fire&Waterworks Technical Service.Ames Fire&Waterworks reserves the right to change or modify product design,construction, FIRE&WATE R WO R KS. specifications,or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames Fire&Waterworks products previously or subsequently sold. A WATTS Brand Specifications Standards In-Building Riser shall be installed as indicated on the plans. NFPA — Designed to allow the contractor to conform to NFPA Riser shall be composed of a single extended 90 degree fitting 24 of fabricated 304 stainless steel tubing, maximum working Where a riser is close to building foundations, underground pressure 200psi(14 bar).The fitting shall have a grooved-end fittings of proper design and type shall be used to avoid pipe joints connection on the outlet(building)side and a CIPS coupler on being located under the foundations. the inlet(underground)side.The grooved end shall include a coupler and cap to facilitate testing of the underground pip End Connections ing.The In-Building Riser shall be an Ames Fire&Waterworks Series IBR. Horizontal End: Mates with Ductile Iron Pipe and AWWA 0900 Pipe(PVC Pipe with Ductile Iron Pipe Equivalent OD's) Utilizes Gasket conforming to UL 157 with"Lock in" gasket configuration Approvals Fittings FM class 1920 SIZE(DN) MATING PIPE OD UL HKQA(4"-10") in. mm in. mm CO41> 0 4 100 6 150 4.8 122 6.9 175 I8 200 9.1 230 10 250 11.1 282 Dimensions —Weights H- A Vertical End: Meets AWWA C-606 dimensions for roll grooved pipe Grooved End (Flange Optional) Meets AWWA C-207 class D for flanges Ratings Meets AWWA C-900 pressure class 200, DR 14 Pipe B Testing Welds are 100% leak tested at the factory CIPS Coupling Tie-Rod Bracket SIZE DESIGN PROOF PRESSURE =111'f „# - in. mm psi bar 4 100 1000 70 I� G rl 6 150 1000 70 8 200 800 56 10 250 800 56 SIZE(DN) WEIGHT A(OD) B C in. mm in. mm ft. cm ft. cm lbs. kg NOTICE 4 100 41/2 114 6 183 6 183 71 32 Inquire with governing authorities for local installation 6 150 65/8 168 6 183 6 183 98 44 requirements 8 200 85/8 219 6 183 6 183 129 59 10 250 103/4 273 6 183 6 183 202 92 **Each B(vertical)and C(horizontal)leg is customizable from 3'to 20'with UUFM NOTICE approvals.Consult with your factory representative for details. The information contained herein is not intended to replace the full product installation and safety information available or the experience of a trained product installer.You are required to thoroughly read all installation instructions and product safety information before beginning the installation of this product. .w AMES FIRE&WATERWORKS A WATTS Brand USA:Backflow Tel:(978)689-6066•Fax:(978)975-8350•AmesFireWater.com USA:Control Valves Tel:(713)943-0688•Fax:(713)944-9445•AmesFireWater.com Canada: Tel:(905)332-4090•Fax:(905)332-7068•AmesFireWater.ca Latin America: Tel:(52)81-1001-8600•AmesFireWater.com ES-A-InBuildingRiser 1626 ©2016 Ames Fire&Waterworks Swing Check Valve FPPI° Full Floating Clapper Assembly Description The bronze*swing check valve features a full floating clapper assembly that provides for a positive seal each time the valve is cycled. This feature improves the swing check valves ability to "clear" any debris that may be present in the water supply. The seat material is NBR which provides for a positive seal even under light residual pressures. Installation Warning Specifications For horizontal installation only. The DO NOT OVER TIGHTEN. Over female by female swing check valve tightening during installation will Valve Body: Cast Bronze` should be installed in accordance crack the valve body. Evidence (85-5-5-5) with commonly used installation of overtightening may not be practices for the fire sprinkler industry. readily visible or apparent upon Clapper Assembly: Forged Brass Proper seal of the threads can be pressurization. accomplished by applying a liberal Seat: amount of PTFE based thread seal- No user serviceable parts. NBR(Chloramine Resistant) ant such as PipeFit®Thread Sealant Sizes: Paste or PTFE Tape. Never use tape 1/2" IPS and paste together. This will cause 3/4" IPS excessive stress on the threaded 1 IPS 1'/4" IPS connection leading to failure of the 11/2" IPS valve. Do not exceed one full turn 2" IPS past hand tight when installing male Female by female threads into the check valve. Rated Pressure: 250 psi *Contains lead.Not for use in water systems intended for human consumption. 5937 DARWIN CT.SUITE 105 C92008ARLSBAD, 0)D 344-1822 +1 (800)344-3775 FAX ©2018 Fire Protection Products,Inc. TT fl as I I ,, H r . o' ,; cLISED LPCB VdS SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS SERIES 728 The Series 728 FireLock valve is a full port,ball valve that is UUFM rated forp 365psi/25 BAR service in all sizes(LPCB and VdS listed for 20 BAR services). i' TM' ,.., 4 ii ;"» 0 Available with grooved or threaded ends(NPT),the valve body is brass.The ball is ,, chrome plated brass with a stainless steel stem.Reinforced seats aid ease of operation and provide a durable,corrosion-free seat.Flow characteristics exceed UL Specification 1091 and FM Approval Standard 1112.The valve is approved for indoor and outdoor use. i Noe DIMENSIONS Approx. H Size Dimensions-Inches/mm Wgt.Each -SII G-ry WI" 1 i! K �t ` rr "` Nominal E to E Height Lbs. 'IGT��\'i�l,l ir'IIII��III Inches/mm A B C 0 E F G H I .1 K kg _��' B 2 84 4.74 0 91 1.67 1.82 2.40 315 4.86 0.68 1.42 3.00 5.1 1/25 Thd XThd 72 120 23 42 46 61 80 123 17 36 76 2.3 I1I•'I ��1 1/a/32 Thd.X Thd. 3.31 4.95 1.10 1.88 2.20 2.61 3.15 4.86 0.68 1 65 3 00 5.8 c , JJ 84 126 28 48 56 66 80 123 17 42 76 2.6 i-.IA j e h/40 Thd.X Thd. 3.66 5.13 1.29 2.06 2.58 2.79 3.15 ! 4.86 0.68 1.83 3.00 6.6 192 130 33 52 66 71 80 1 123 17 47 76 3.0 GROOVED X GROOVED 4.33 5.49 1.69 2.42 3.38 3.15 3.15 4.86 0.68 2.16 3 00 8.5 2/50Thd.XThd H . 110 140 43 62 86 80 80 123 17 55 76 3.9 G 7.25 495 1.10 1.87 2.20 2.61 3.15 4.86 0.68 319 300 5 1 Ya/32 Grv.x Gry 184 126 1 28 48 56 66 80 123 17 81 76 34 / �� \ K I) ="r- 1 Yz/40 Gry X Grv* 7.25 5.17 1.29 2.10 2.58 2.83 315 4.86 0.68 319 3.00 8.5 _ r ..J ri `• 184 31 33 53 66 72 80 123 17 81 76 3 9 II�`t )i !i,�kIIIt��Ill B 7.25 5.47 1.69 2.40 3 38 3.13 315 4.86 0.68 319 3.00 10.5 �-�_ A n� 2/50 Grv.XGrv.* of �� E '! ��IGUIIp%� 184 . 139 i 43 ,... 61 86 80 80 123 17 81 76 4.8 'IIIMI l ,,\\ ,� *1'h and 2740 and 50mm sizes feature a /z"/l2mm tap(Groove by Groove only). C 1-*' E A THREADED X THREADED PERFORMANCE SIZE Equivalent SIZE Equivalent Nominal Inches/mm Feet/meters of Pipe Nominal Inches/mm Feet/meters of Pipe 1/25ThreaoX1Hread 0.5 1Ya/32Groove XGroove �.2 1 Ya/32 Thread X Thread 003 11/2/40 Groove X Groove 0.2 10 0 11/2/40 Thread X Thread 2/50 Groove X Groove 2 2/50 Thread X Thread 1.0 0.3 • JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2011 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ictaulic° REV H 10.17 1 IPS CARTON STEEL PIPE—FIRE PROTECTION VALVES 1 U. 1 / FireLock® Ball Valve SERIES 728 SWITCH AND WIRING 1.The supervisory switch contains two single pole,double throw,pre-wired switches. 2.Switches are rated: 10 amps @ 125 or 250 VAC/60 Hz 0.50 amps @ 125 VDC 0.25 amps @ 250 VDC 3.Switches supervise the valve in the"OPEN"position. 4.One switch has two#18 insulated wires per terminal,which permit complete supervision of leads (refer to diagrams and notes below).The second switch has one#18 insulated wire per terminal. This double circuit provides flexibility to operate two electrical devices at separate locations,such as an indicating light and an audible alarm,in the area that the valve is installed. 5.A#14 insulated ground lead(green)is provided. Switch#1=S1 For connection to the supervisory circuit of a UL Listed alarm control panel Switch#2=S2 Auxiliary switch that may be connected to auxiliary devices,per the authority having jurisdiction Normally Closed:(2)Blue S1 Common:(2)Yellow Normally Closed:Blue with Orange Stripe S2 Normally Open:Brown with Orange Stripe Common:Yellow with Orange Stripe UL LISTED ` (UNCTION BOX FIRE CONTROL PAN 10 END-OF-LINE RESISTOR, ,` ' CONTROL PANEL OR NEXT INDICATOR CONDUIT SUPERVISORY ill �.�a''.- I.� CIRCUIT N0. COM. r 1..• SWITCH _ /'NPT C10AACT RATING125AND: � ®I CONDOR CONNECTORS 10AA50VAC, D 50125, OA AT 125 VDC, 0.25 AT 250 VDC WIRE NUTS BELL OR VOLTAGE SOURCE HORN Switch 1:1 leads per terminal Switch 2:1 lead per terminal NOTE:The above diagram shows a connection between the common terminal(yellow—S1 and yellow- with-orange stripe—S2)and the normally closed terminal(blue—S1 and blue-with-orange stripe—S2). In this example,the indicator light and alarm will stay on until the valve is fully open.When the valve is fully open,the indicator light and alarm will go out.Cap off any unused wires(e.g.brown with orange stripe). Only S1(two leads per terminal)may be connected to the fire alarm control panel. The connection of the alarm switch wiring shall be in accordance with N FPA 72 and the auxiliary switch per NFPA 70(NEC). MATERIAL SPECIFICATIONS Valve Body: Brass ASTM B124 Ball: Chrome Plated Brass Ball Valve Stem:316 Stainless Steel Seat: Carbon Filled (TFE)tetrafluoroethylene Stem Nut: Brass ASTM B-16 C36000 Actuator: Brass traveling nut,on a steel lead screw, in a ductile iron housing • www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2011 VICTAULIC COMPANY.ALL RIGHTS RESERVED. jctaulic° 10.17 2 REV H Pr POTTER RD13 The Symbol of Protection Residential Riser Features , • Pre-assembled and pressure tested • Available in 1",1 1/4", 1 1/2",&2"nominal pipe size models Jo` • Female adapter ships loose so riser can be installed in a ti confined space • Fits in standard 2X4 construction walls E tg l .W • Installation must be performed by qualified personnel and in accordance with all national and local codes and ordinances. • Shock hazard.Disconnect power source before servicing.Serious injury or death could result. • Risk of explosion.Not for use in hazardous locations. Serious in'u or death could result. Description Flow Switch Technical Specifications The RD13 Riser (with NPT connectors) is constructed from Listed Dimensions See Fig 2 CPVC products suitable for fire sprinkler services subject to the limitations and installation requirements of Flameguard®CPVC pipe Service Pressure 175 PSI(12,07 BAR)-UL and Spears®CPVC fittings.The RD13 Riser incorporates a VSR-SG Flow Sensitivity flow switch,gauge,and drain/test valve. The VSR-SG flow switch is Range for Signal 4-10 GPM(15-38 LPM)-UL equipped with union connection to facilitate the installation and removal Maximum Surge 18 FPS(5.5 m/s) of the switch in confined spaces. Two sets of SPDT(Form C) Installation 10.0 Amps at 125/250VAC 1. Using appropriate sealant, thread the female adapter on to the Contact Ratings 2.0 Amps at 30VDC Resistive10 mAmps min. at main water supply. Then glue the riser assembly to the female 24VDC Resistive adapter. Pipe the drain connection to an adequate drain location 10 mAmps min.at 24V DC capable of handling the drain discharge.The riser can be mounted in the horizontal or verticalosition.Direction of flow is indicated Environmental P Temperature range:40°F-120°F(4.5°C-49°C)-UL in Fig. 1. The waterfiow switch must be located on the top or Limitations on the side of the pipe when installed in the horizontal position. Conduit Two knockouts provided for 1/2"conduit This will prevent debris from entering the throat of the waterflow Entrances switch which could interfere with proper operation. Listings UL,CUL CSFM Listed,and CE Marked 2. Following CPVC manufacturer's instructions for preparation and gluing of CPVC piping systems,glue the main riser to the main Specifications subject to change without notice supply line for the sprinkler heads.NOTE:All glued connections Service Use must be completed and cured before the flowswitch is installed. Automatic Sprinkler NFPA-13 (Continued on page 2). One or two family dwelling NFPA-13D ® CAUTION Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 British Standard BS9251 Do not over-tighten the union nut,hand tighten only.Use of a wrench may cause damage to the union nut. Potter Electric Signal Company,LLC • St. Louis,MO • Tech Support: 866-956-0988/Customer Service: 866-572-3005 • www.pottersignal.com 5401152-REV K • 2/15 PAGE 1 OF 3 P POTTER RD13 - The Symbol of Protection Residential Riser Installation (Continued) 3. A thread sealant shall be used in making threaded connections. Teflon®thread tape is the recommended sealant. Some thread sealants other than Teflon thread tape contain solvents or other materials that may be damaging to CPVC.For other types of thread sealants,which have been specifically investigated and confirmed to be"System Compatible",refer to www.spearsmfg.com.Attach gauge to riser.Apply Teflon®tape to male fitting of gauge only. See Fig 1. 4. Check to make sure the proper paddle is installed on the switch. (Paddle size must match the riser pipe size and Tee manufacture.) 5. Install the flow switch to the RD13 Riser.Verify that the o-ring is properly positioned in its groove.Hand tighten the nut to the union after orienting the flow switch in the appropriate direction to detect waterflow.The paddle must not rub the inside of the Tee or bind in any way.The stem should move freely when operated by hand. See Fig. 1.NOTE:Do not leave switch cover off for an extended period of time. 6. The side of flow switch must be perpendicular with the riser piping.See Fig.3. Testing The frequency of inspection and testing for the Model VSR-SG and its associated protective monitoring system,should be in accordance with applicable Codes and Standards and/or the authority having jurisdiction(manufacturer recommends quarterly or more frequently.) If provided,the inspector's test valve(usually located at the end of the most remote branch line)should be used for test purposes.If there is no remote inspection test connection; a short length of hose may be connected to the discharge of the 1"drain line valve,or if the drain line is connected to a drain such as a slop sink or storm drain that will sufficiently handle the discharge of the main drain valve.The drain valve can be used to test the operation of the VSR-SG switch. A minimum flow of 10 GPM(38 LPM)is required to activate this switch.An orifice equal to the smallest sprinkler head orifice used in the system shall be attached to the drain line for testing purposes. Maintenance The VSR-SG waterflow switch should provide years of trouble-free service. The retard and switch assembly are easily field replaceable. In the unlikely event that either component does not perform properly,please order replacement retard switch assembly stock number 1029030.There is no maintenance required,only periodic testing and inspection.. Removal • To prevent accidental water damage,all control valves should be shut tight and the system completely drained before waterflow detectors are removed or replaced. • Turn off electrical power to the detector,then disconnect wiring. • Loosen nut on union fitting. • Lift detector clear of pipe. Fig 1 Optional Cover Tamper Retard Adjustment Switch The delay can be adjusted by rotating the retard adjustment knob from 0 111 to the max setting(60-90 seconds). The time delay should be set at the ��� DO NOT LEAVE minimum required to prevent false alarms. Retard COVER OFF Adjusting iFOR EXTENDED Knob \‘'5•A1<*01 I Pj1% PERIOD OF TIME 11I Mount so arrow tit on base points WATERFLOwIRECTiON OFin direction of � \ waterflow <3, 0 1"Male Fitting on DWG. #1063-3 All Sizes Riser may , Important: be 1",1/4", The paddles have raised lettering that show the pipe size and the TEE 1 1/2",or 2" , 10 manufacturer they are to be used with. The proper paddle must be used. The paddle must be properly attached and the screw that holds the paddle v4 must be securely tightened. Katie Potter Electric Signal Company, LLC • St. Louis,MO • Tech Support: 866-956-0988/Customer Service: 866-572-3005 • www.pottersignal.com 5401152-REV K • 2/15 PAGE 2 OF 3 P POTTER RD13 The Symbol of Protection Residential Riser Dimensions (See Chart Below) Orientation Fig 2 Fig 3 E b F HK 3 1/2"Gauge I (Shipped Loose) 1 . 90° A B C --. _r i NE 1"NPT tag�® j1 vii-4-Drain o Valve .____. — lel il I, to VSR-SG Flow Switch II A CAUTION T NPT Adaptor(Shipped Loose) Flow switch must be properly orientated.Side of cover must be perpendicular with the pipe.Improper orientation could delay or prevent notification of waterflow. *RD13 Risers(ASSEMBLED DIMENSIONS) Riser Model Dimension"A" Dimension"B" Dimension"C" Dimension"D" Dimension"E" Dimension"F" Part Number Size Number (in) (mm.) (in.) (mm.) (in.) (mm.) (in.) (mm.) (in) (mm.) (in.) (mm.) 1" RD13-100-1 1119067 16 406 15 3/4 400 14 7/8 378 14 5/8 371 12 1/4 311 10 1/2 267 1 1/4" RD13-125-1 1119077 16 5/8 422 16 1/2 419 15 1/2 394 15 3/8 391 12 1/2 318 10 5/8 270 1 1/2" RD13-150-1 1119087 N/A N/A 16 3/4 425 N/A N/A 15 5/8 397 12 3/4 324 10 3/4 273 2" RD13-200-1 1119097 N/A N/A 18 1/4 464 N/A N/A 16 7/8 429 13 3/8 340 11 1/8 283 Ordering Information Ordering Information Nominal Pipe Model Part Number Size Optional: Cover Tamper Switch Kit,stock no.0090148 1" RD13 Riser 1119067 Replaceable Components:Retard/Switch Assembly,stock no. 1029030 1 1/4" RD13 Riser 1119077 Gauge,Flow Switch,and NPT Adapter shipped loose in box. 1 1/2" RD13 Riser 1119087 2" RD13 Riser 1119097 Potter Electric Signal Company,LLC • St.Louis,MO • Tech Support: 866-956-0988/Customer Service: 866-572-3005 • www.pottersignal.com Iso 9001:2008DESIGNING,MANUFACTURING, CERTIFIED I&DISTRIBUTING QUALITY SYSTEMS 5401152-REV K • 2/15 PAGE 3 OF 3 Single Inlet Connection .41 FP ' I 111 For Residential systems, UL Listed Description Designed specifically residential sprinkler systems, the Single Inlet Connection features all brass* construction with an integrally cast mounting/identification plate. The connection comes equipped with a single 11/" NST gasketed female threaded swivel +r i inlet and a 11/2" NST plug to protect the threaded swivel from damage or the introduction • of foreign materials when not in use.The out let is 11/2" NPT female thread for connect to the end of 11/2"threaded male pipe.The integrated identification plate has three drilled mounting holes for attachment to a mounting surface such as an exterior wall of a building or other structure. Fasteners used should be suitable for the material to which the connection is being attached. Installation Specifications Install according to applicable codes using customary installation methods Matfor the installation of threaded connections. A suitable threaded sealant Bra B16 s B16 Brass" such as PipeFit Thread Sealing Paste with PTFE or PTFE thread Sealant Tape should be used. Where required, a check valve should be used to Type: maintain system pressure. Single Outlet PL Sizes: 11/2" FNPT x 11/" FNST Other Specifications: Integral Identification sign "Auto Sprinkler"with mounting holes. *Contains lead.Not for use in water systems intended for human consumption. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL+1 800 344-1822 0 FAX+1 800 344-3775 ©2012 Fire Protection Products,Inc. LISTED a FlameGuard® SPEARS CPVC FIRE SPRINKLER PRODUCTS FG-2-0215 Complete System of Pipe, Fittings & Solvent Cement Corrosion Resistant • Superior Flow • Ease of Installation Spears® FlameGuard®CPVC Fire Sprinkler Products provide a cost effective 'r,:- ' %r alternative to metal systems with advantages of high corrosion resistance, improved 1\ 9. system hydraulics, ease IEJ �� �' ' of installation and quick �4§ assembly with common tools." i , r, 4,„,1,,,,, CPVC Fire Sprinkler Systems d , .,. ,:,.. __ uard are based on proven productslip ; - -.4 _ am NU SPRINKUR PRODUCTS that have been in continuous , service for over 40 years. Spears® FlameGuard® products are approved by UL®,FM" Global,LPCB and x... Certified by NSF International for potable water use. Check local codes for restrictions and limitations. v � Corrosion Resistant CPVC Material Does Not Easy Installation for Lower Costs Sustain Biological Growth FlameGuard® CPVC system installations Unlike metal systems, FlameGuard®CPVC significantly reduce costs over conventional metal products never rust, scale or pit and do not sustain piping by virtually eliminating prefabrication. biological growth- a cause of Microbiologically Systems can be fully installed on site using solvent Influenced Corrosion(MIC)which can destroy metal cement joining methods. fire sprinkler systems from the inside out. UL®Listed for U.S. and Canada in Superior Flow Characteristics for Lower NFPA 13, 13R & 13D Systems Friction Losses FlameGuard® CPVC Fire Sprinkler Products The smooth-wall interior surfaces of FlameGuard® are UL® listed for U.S. and Canada applications CPVC systems result in reduced friction loss over for Light Hazard occupancies as defined in NFPA metal systems. The design flow characteristics remain 13,Residential occupancies up to and including constant throughout the life of the product because 4-stories as defined in NFPA 13R, and Residential there is no interior corrosion in the system due to occupancies for one and two family dwellings and microbiological activity. manufactured homes as defined in NFPA 13D. Consult Spears® FlameGuard®CPVC Fire Sprinkler Pressure Rated to 175 psi (1200kpa) @ 150°F Products Installation Instructions and NFPA Standards (65°C) for additional applications including air plenum, FlameGuard®CPVC Products are produced in system risers,concealed, exposed, underground, combinations of Schedule 40 and Schedule 80 Fitting combustable attic, garage,basement and low configurations con-forming to ASTM F 438 or F 439 pressure dry piping installations. standards and FlameGuard® SDR 13.5 CPVC Fire Sprinkler Pipe conforming to ASTM F 442 standards. Full Limited Lifetime Warranty UL® and FM® Rated working pressure is 175 psi FlameGuard®CPVC Fire Sprinkler Products (1200kpa)@ 150°F (65°C)(LPCB rated to 120°F) carry a limited lifetime warranty against defects (49°C). in material or workmanship. Consult Spears® warranty for additional details. PROGRESSIVE PRODUCTS FROM SPEARS® °" "' c INNOVATION & TECHNOLOGY po�P�Bao w Visit our website at www.spearsmfg.com Assessed to ISO 9001:2003 Certificate number 293 : ':• .k ':•• - 1 •Il: .: ► k : AZ.rITS1111111 V27 K4 9 7 C®US SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS Residential Pendent and Recessed Pendent V2740 QUICK RESPONSE This Model V27 residential sprinkler is designed to meet the requirements of NFPA 13, 13D P and 13R for residential use in a variety of room sizes,depending upon available operating pressure and room configuration.The design incorporates state-of-the-art, heat responsive, It frangible glass bulb design(quick response)for prompt, precise operation. The die cast frame is more streamlined and attractive than traditional sand cast frames. It is cast with a hex-shaped wrench boss to allow easy tightening from many angles, reducing assembly effort.This sprinkler is available in various finishes to meet many design requirements. PENDENT (V2740) SPRINKLER OPERATION: The operating mechanism is a frangible glass bulb which contains a heat responsive liquid. During a fire,the ambient temperature rises causing the liquid in the bulb to expand.When the ambient temperature reaches the rated temperature of the sprinkler,the bulb shatters.As a result,the waterway is cleared of all sealing parts and water is discharged towards the deflector.The deflector is designed to distribute the water in a pattern that is most effective in controlling the fire. COVERAGE: Residential spray coverage up to 20 feet x 20 feet/6.1 m x 6.1 m room sizes per NFPA. TECHNICAL SPECIFICATIONS: Model:V274O ACCESSORIES Style: Pendent and Recessed Pendent Installation Wrench: Nominal Orifice Size:%a'/12mm • Open End:V27 K-Factor:4.9 Imp./7.1 S.I.^for room sizes up to • Recessed:V27-1 `.,... 20'/6.1m Sprinkler Finishes: Nominal Thread Size:1/2' NPT/15mm • Plain brass Max.Working Pressure: 175 psi/1200 kPa • Chrome plated ` � Factory Hydrostatic Test: 100%@ 500psi/ • White painted**** 3450 kPa • Custom painted �� �� Min.Operating Pressure:7psi/48kPa For escutcheons,cabinets and other accessories 1r�JJ Temperature Rating:See chart on page 3 refer• to separate sheet. �/ �♦• MATERIAL SPECIFICATIONS ^ For K-Factor when pressure is measured in 1 Bar, multiply S.I. units by 10.0. lleo UPendent Deflector: Bronze per UNS C51000 `� *Teflon is a registered trademark of Bulb:Glass with glycerin solution Dupont Co. Bulb Nominal Diameter: **UL Listed for corrosion resistance in all ,w, i Quick Response:3.0mm configurations. Load Screw: Bronze per UNS :mon NOTE:Weather resistant recessed escutcheon Pip Cap: Bronze per UNS C65100 available upon request. •..ilt Seal:Teflon*tape St �,` !, Frame: Die cast brass 65-30 SIV • Exaggerated for clarity JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED. AtaUl•cs REV E 40, FIRE PROTECTION PRODUCTS—AUTOMATIC SPRINKLERS 4U.4/ 4.9 Residential Pendent and Recessed Pendent V2740 QUICK RESPONSE APPROVALS/LISTINGS Orifice Nominal Approved Temperature Ratings Model Size K-Factor Response Deflector Type °F/'C 1' Inches Imperial tnm S.1.^ cULus V2740 I 76 4.9 Quick Pendent 155,175 12 7.1 68,79 V2740 '7A6 4.9 Quick Recessed Pendent 155,175 12 7.1 Up to Y'Adjustment* 68,79 V2740 '6 4.9 Quick Recessed Pendent 155,175 2 7.1 Up to 3/4"Adjustment# 68,79 #Listings and approval as of printing. A For K-Factor when pressure is measured in Bar,multiply S.I.units by 10.0. *For 12'x 12'to 20'x 20'rooms #For 12'x 12'to 18'x 18'rooms RATINGS All glass bulbs are rated for temperatures from—67°F/-55°C to those shown in table below. Temperature—°F/°C Victaulic Sprinkler Temperature Part Nominal Temperature Maximum Ambient Classification Identification Rating Temperature Allowed Glass Bulb Color Ordinary C 68 138 Red Intermediate F 79 63 Yellow ORDERING INFORMATION Please specify the following when ordering: Sprinkler Model Number Style Temperature Rating K-Factor Thread Size I Quantity Sprinkler Finish Escutcheon Finish Wrench Model Number www.victaulic.com jcta uliic° VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 40.47 2 REV E FIRE PROTECTION PRODUCTS-AUTOMATIC SPRINKLERS 4U.4/ V27, K4.9 Residential Pendent and Recessed Pendent V2740 QUICK RESPONSE ROOM SIZE Victaulic V2740,4.9 K-Factor Pendent Sprinkler For Ceiling types refer to NFPA 13, 13R or 13D 2013 Editions Max. Ordinary Temp Intermediate Temp Coverage Rating Rating Deflector to Installation Minimum Area' 155°F/68-C 175°F/79°C Ceiling Type Spacing Ftowtb) pressure, Flowtb) Pre Ft.x Ft. GPM PSI GPM PSI t. ' m z m L/min bar L/min bar 12 X 12 13 7.0 13 7.0 3.7 X 3.7 49.2 0.48 49.2 0.48 14X14 13 7.0 13 7.0 4.3 X 4.3 49.2 0.48 49.2 0.48 34"recessed 6 X 16 3 70 3 7.0 Escutcheon(r) 8.0 4.9 X 4.9 49.2 048 492 048 1'/,c to 4 inch or non-recessed 2.4 y per NFPA 13,13R 18 X 18 17 12 17 12 or 13D 5.5 X 5.5 64.3 0.83 64.3 0.83 20X20 20 16.7 20 16.7 6.1 X 6.1 1 75.7 1.15 75.7 1.15 (a)For coverage area dimensions less than or between those indicated,use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. (b)For NFPA 13 residential applications,the greater of 0.1gpm/ft2 over the design area of the flow in accordance with the criteria in the table must be used. (c) For 20 x 20 Coverage Area-1"Maximum Recess www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ICta1fuI.C: REV E 40.47 5 , „ VRE PROJEC I h, ; I — I 1,1 •; L ; 1114 t V27 K4• flx COUs LISTED SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS Residential Horizontal Sidewall, Recessed Horizontal Sidewall V2738 QUICK RESPONSE These Model V2738 residential sprinklers are designed to meet the requirements of the 2002 ! „* or later NFPA 13, 13D and 13R for residential use.The Model V2738 is UL Listed for use under smooth flat horizontal ceilings.The design incorporates stateof-the-art, heat responsive, frangible glass bulb design(quick response)for prompt, precise operation. The die cast frame is more streamlined and attractive than traditional sand cast frames. It HORIZONTAL SIDEWALL RECESSED (V2738) HORIZONTAL SIDEWALL is cast with a hex-shaped wrench boss to allow easy tightening from many angles, reducing (V2738) assembly effort.This sprinkler is available in various finishes to meet many design requirements. SPRINKLER OPERATION: The operating mechanism is a frangible glass bulb which contains a heat responsive liquid. During a fire,the ambient temperature rises causing the liquid in the bulb to expand.When the ambient tem- perature reaches the rated temperature of the sprinkler,the bulb shatters.As a result,the waterway is cleared of all sealing parts and water is discharged towards the deflector.The deflector is designed to distribute the water in a pattern that is most effective in controlling the fire. COVERAGE: Residential spray coverage up to 320sq.ft./29.9sq.m room sizes per NFPA. TECHNICAL SPECIFICATIONS: Models:V2738 Accessories Style: Residential Horizontal Installation Wrench: Sidewall and Recessed Horizontal • Open End:V27 Sidewall • Recessed:V27-2 �'._.1/4Nominal Orifice Size:7/16'/12 mm Sprinkler Finishes: K-Factor:4.2lmp./6.1S.1.^ • Plain brass � 1,� Nominal Thread Size:12' NPT/l5mm • Chrome plated -A) _ > Max.Working Pressure: 175 psi/1200kPa • White painted*" Factory Hydrostatic Test: • Custom painted** $ 100% 500 psi/3450 kPa For escutcheons,cabinets and other accessories Min.Operating Pressure:7psi/48kPa refer to separate sheet. VP � Temperature Rating:See chart on page 2 NOTE:Weather resistant recessed escutcheons available upon request. Material Specifications Deflector: Bronze per UNS C51000 A For K-Factor when pressure is measured in Bulb:Glass with glycerin solution. Bar, multiply S.I. units by 10.0. Bulb Nominal Diameter: * Teflon is a registered trademark of Dupont Co. • Quick Response:3.0mm **UL Listed for corrosion resistance. Load Screw: Bronze per UNS C65100 Pip Cap: Bronze per UNS C65100 Spring: Beryllium nickel Seal:Teflon*tape Frame: Die cast brass 65-30 Lodgement Spring: Stainless steel per UNS S30200 JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com iCtaUliCC VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED. —. •- REV D 40.54 1 FIRE PROTECTION PRODUCTS—AU1OMA1IC SPRINKLERS 40.54 V27 K4 . . Residential Horizontal Sidewall, Recessed Horizontal Sidewall V2738 QUICK RESPONSE APPROVALS/LISTINGS Orifice Nominal Approved Temperature Model Size K-Factor Response Deflector Type Ratings`FrC Inches imperial Standard mm S.1.^ or Quick cULus NYC/MEA# CSFM 7/v4.2 155,175 155,175 155,175 V2738 11 61 Quick Horizontal Sidewall 68,79 68,79 68,79 7/16 4.2 Recessed Horizontal Sidewall 155,175 155,175 155,175 V2738 11 ! 61 Quick Up to 3/4"Adjustment 68,79 68,79 68,79 # Listings and approval as of printing. A For K-Factor when pressure is measured in Bar,multiply S.I.units by 10.0. t MEA#62-99-E. RATINGS All glass bulbs are rated for temperatures from—67°F/-55°C to those shown in table below. Victaulic Temperature-°F/°C Sprinkler Temperature Part Nominal Temperature Maximum Ambient Classification Identification Rating Temperature Allowed Glass Bulb Color 155Ordinary C 8 00 Red 68 638 Intermediate E �9 66 Yellow ORDERING INFORMATION Please specify the following when ordering: Sprinkler Model Number Style Temperature Rating K-Factor Thread Size Quantity Sprinkler Finish Escutcheon Finish Wrench Model Number VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.CO 2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED. �CtaUII- 40.54 2 1,Z EV D , FIRE PROTECTION PRODUCTS-AUTOMATIC SPRINKLERS 4U■b4 V27, Residential Horizontal Sidewall, Recessed Horizontal Sidewall V2738 QUICK RESPONSE ROOM SIZE Victaulic V2738,4.2 K-Factor Horizontal Sidewall Sprinkler For Ceiling types refer to NFPA 13, 13R or 13D 2013 Editions Max.Coverage Area° Ordinary Temp Intermediate Temp Top of Width X Max. Rating Rating Deflector to Installation Minimum Length'°' Spacing 155°F/68'C 175-F/79°C Ceiling Type Spacing Flow , pressure, FIovviN Pressure, Ft,o Ft, Ft, GPM PSI GPM PSI Ft m t m ni L/min bar L/min bar a ;�L _ ._ In...c 12 X 12 12 14 11.1 14 11.1 3.7 X 3.7 3.7 53.0 0.76 53.0 0.76 14 X 14 14 14 11.1 14 11.1 4.3 X 4.3 4.3 53.0 0.76 53.0 _ 0.76 16X 16 16 17 16.4 17 16.4 4to6inches 4.9X4.9 4.9 64.4 1.13 64.4 j 1.13 16X18 16 19 20.5 19 20.5 j i 4.9X5.5 49 72.0 1.4 72.0 1.4 3/4"recessed 16 X 20 16 23 30.0 23 30.0 using 4.9 X 6.1 4.9 87.1 21 87.1 2.1 Escutcheon or 8.0 - 2.4 12 X 12 12 15 12.8 15 12.8 non-recessed per 3.7 X 3.7 3.7 56.8 0.88 56.8 0.88 1NFPA , 13 14 X 14 14 17 16.4 17 16.4 4.3 X 4.3 4.3 64.4 1.13 64.4 1.13 16 X 16 16 1 19 20.5 19 20.5 6 to 12 inches 4.9X4.9 4.9 72.0 1.4 72.0 1.4 16 X 18 16 24 32.6 24 32.6 4.9 X 5.5 I 4.9 90.8 2.25 90.8 2.25 16 X 20 i 16 28 44.4 28 44.4 4.9 X 6.1 4.9 106.0 3.06 106.0 3.06 (a)For coverage area dimensions less than or between those indicated,use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. (b)For NFPA 13 residential applications,the greater of 0.1gpm/ft2 over the design area of the flow in accordance with the criteria in the table must be used. (c)The Width X Length dimension refers to the Width(backwall where the sprinkler is located)times the Length(horizontal throw of sprinkler) www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.m 2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ICta'�UI1�. REV D 40.54 5 FireLockTM V36, K5.6 Models V3605 V3606ata�,��a• ' 40.60 Dry Type Pendants Technical Specifications: Standard and Quick Response Models: V3606 and V3605 Style: Pendent, Recessed Pendent or Intermediate Level ,. t Pendent (' 1 Nominal Orifice Size: 1/2"/13 mm MI P Orifice Insert: Stainless steel per UNS S30300 Flush Sleeve and Plain Intermediate Extended Recessed Skirt Barrel K-Factor: 5.6 Imp./8.1 SI' Approvals/Listings: Nominal Thread Size: 1" NPT/33.7 mm c®us ® Max. Working Pressure: 175 psi/1200 kPa LISTED See Victaulic Publication 10.01 for more details. Factory Hydrostatic Test: 100% @ 500 psi/3450 kPa Min. Operating Pressure: 7psi/48 kPa Product Description: Temperature Rating: See chart on page 3. The Model V36 Series Dry Type Pendent and Recessed Pendent Sprinklers have been redesigned utilizing 'For K-Factor when pressure is measured in Bar,multiply S.I.units by 10.0. stainless steel internal components. The V36 Dry Sprinkler is used in special applications such as freezing environments and conditions where sediment or Dry SprP WI materials might accumulate in ordinary drop nipples. '`���Et IIIV The Model V3606 and V3605 Intermediate Level Pendent 1 sprinklers incorporate a water shield plate to prevent / i water from higher level sprinklers from interfering with 0 normal operation. These intermediate level sprinklers are 0 0 designed for use in intermediate levels of rack storage or other open grate storage arrangements, where they may be exposed to upper level or ceiling level sprinklers. P�,1 Coverage 1� %1' For coverage area and sprinkler placement, refer to NFPA �'�� FIIt 13 or applicable standards. �;c? ski I � II; 14 Exaggerated for clarity Job/Owner Engineer System No. Spec Section Location Paragraph Contractor Approved Submitted By Date Date victaulic.com I Sprinklers I FireLock'" I K5.6, V36 I Publication 40.60 40.60 3123 Rev I Updated 03/2018 ©2018 Victaulic Company.All rights reserved. 1IIct auhiic` victaulic.com I Sprinklers I FireLock® I K5.6, V36 I Publication 40.60 Material Specifications: Accessories Deflector: Brass per UNS C22000 or Stainless Steel per Installation Wrench: UNS S30400 Model V36 Open End and Recessed Wrenches fit all V36 Series frames. Bulb: Glass with glycerin solution Bulb Nominal Diameter: Sprinkler Finishes: ❑ Plain brass ❑ Standard: 5.0 mm ❑ Quick Response: 3.0 mm ❑ Chrome plated ❑ White painted3 4 Split Spacer: Stainless steel per UNS S30300 ❑ Flat black painted3 4 Load Screw: Brass per UNS C36000 ❑ Custom painted3 4 Pip Cap: Stainless steel per UNS S30300 El VC-2505 Spring Seal Assembly: Teflon2 coated Beryllium nickel 155, 200, 286 SR Only: alloy and stainless steel per UNS S30300 ❑ Wax4 Frame: Die cast brass For cabinets and other accessories refer to separate sheet. Outer Tube: Galvanized steel pipe 2 Teflon is a registered trademark of Dupont Co. Not available on the Intermediate Level Style Pendent. Inner Tube: Stainless steel per UNS S30400 °UL Listed for corrosion resistance. Escutcheon/Plate: 1010- 1018 mild steel and stainless 5 UL Listed and FM Approved for corrosion resistance. steel NOTE:Weather resistant escutcheon available upon request. Torsion Spring: SST Wire 40.60 3123 Rev I Updated 03/2018 ©2018 Victaulic Company.All rights reserved. victaulic.com 2 jctaulic° victaulic.com I Sprinklers I FireLock® K5.6, V36 I Publication 40.60 Approvals/Listings: , APPROVALS/LISTINGS Model V3606 V3606 V3605 V3605 Orifice Size(inches) Y 1/2 1 Y Orifice Size(mm) 13 13 13 13 Nominal K Factor Imperial 5.6 5.6 5.6 5.6 Nominal K Factor 5.1.6 8.1 8.1 8.1 8.1 Response Quick Quick Standard Standard Deflector Type Pendent Recessed Pendent Pendent Recessed Pendent Approved Temperature Ratings F°/C° 135°F/57°C 135°F/57°C 135"F/57°C 135"F/57°C cULus 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 200°F/93°C 200"F!93°C 200°F/93°C 200°F/93°C 286°F/141°C 286°F/141°C 286°F/141°C 286°F/141°C 135°F/57°C135°F/57°C 135°F/57°C 135°F/57°C FM 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 286°F/141°C 286°F/141°C 6 For K-Factor when pressure is measured in Bar,multiply S.I.units by 10. Note:Listings and approval as of printing.Temperatures are listed for all hazards and approved for V3605 and V3606 dry sprinklers up to 48"length. Dimensions: NOTE:The"A"dimension of a dry sprinkler,which extends into a freezer from a wet piping system,must take into account the wall or ceiling thickness of the freezer.See IMPORTANT INSTALLATION INFORMATION later in this document. _ Tee with same outlet size ———— Tee with same outlet size Tee with same outlet sire [1— -n as sprinkler thread size. as sprinkler thread size. nn------ n as sprinkler thread size. ' See"Important InstallationII See"Important Installation -------n See"Important Installati�n Information",later in this _ _I Information",later in /•• .. P I this document Information',later in th s document document NPT 1"NPT 1"NET "A" 13/4"Min.Dia. (Min.11/4") 1rHole in Ceiling "A„ 1 i7 1 1.; .. (Min.11") Ain.11/4") 11/2"Min.Dia. —1 r Hole in Ceiling Two Piece Escutcheon ++ 2'h"Min. moor l I�//Al l��/////. MOI 4"Max. 1 �, 3"Dia. —. ltl�� — 2' 3%:"Dia. 3"Dia.— I$_�I I� i ,/` 1 Sleeve and Skirt --a"-- Flush Intermediate Level Pendent _ _ Tee with same outlet size --- Ir as sprinkler thread size. — Tee with same outlet size /• -----31 Tee with same outlet size as sprinkler thread size. See"Important Installation t as sprinkler thread size. See"Important Installation Information",later in See"Important Installation Information",later in this • this document 1"NPT -- Information",later in thisit' document } document NPT q" 1"NPTz"Min.Dia. "A" Hole in Ceiling (Min.1W) (Min 1Y<<") „A" t7 Al l%��� 3h� (Min. Collar 1 72"Min.Dia. Hole in Ceiling imam33/a"Min. �� //ain ���//////hf 11/2" I'Io Two Piece 5"Max. ``� 1"Min. irr�n I`.�I 1 ,�` Escutcheon II IIS Ceiling Cup �"` 13/4"Max. n Plain Barrel _. 215/6"Dia.— Extended Recessed 40.60 3123 Rev I Updated 03/2018 ©2018 Victaulic Company.All rights reserved. victaulic.com 3 ilctaulic` FireLock® V36, K5.6 jctaulic° Models V3609, V3610 40.64 Dry Type Standard Spray, Light Hazard Technical Specifications: Horizontal and Recessed Horizontal Sidewall Standard and Quick Response Models: V3610 and V3609 Style: Horizontal Sidewall and Recessed Horizontal Sidewall Nominal Orifice Size: 1/2"/13 mm Flush Dry Recessed Orifice Insert: Stainless steeler UNS S30300 Horizontal Sidewall Horizontal Sidewall p K-Factor: 5.6 Imp./8.1 S.I.1 itt* a — Nominal Thread Size: 1" NPT/33.7 mm /41, Max. Working Pressure: 175 psi/1200 kPa Dry Sleeve&Skirt Extended Plain Horizontal Sidewall Horizontal Sidewall Horizontal Sidewall Factory Hydrostatic Test: 100% @ 500 psi/3450 kPa Approvals/Listings: Min. Operating Pressure: 7psi/48 kPa c0 us ® Temperature Rating: See chart on page 3. LISTED 'For K-Factor when pressure is measured in Bar,multiply S.I.units by 10.0. See Victaulic Publication 10.01 for more details. Product Description: ' The V36 dry sprinkler is used in special applications sucht.4.0A•eilrA''s''s''s''s''s''s''s''s''s''st lel' �r �ifryyHy i/ i as freezing environments and conditions where sediment ;"i,r C or foreign materials might accumulate in ordinary ,,-yi ' =yyy ' ��...40 horizontal pipe nipples. �""r"�'y'y'y'y'y'y'y'y'y'y'y� ISIS The Model V36 Dry Type Horizontal Sidewall Sprinkler P utilizes a frangible glass bulb.At the bulb's rated Exaggerated for clarity temperature,the sprinkler opens releasing the bulb seat assembly,causing the inner tube assembly to move, allowing the spring assembly to pivot alongside the inner tube.At this time,water flows through the sprinkler and is distributed by the deflector, in an approved discharge pattern. Coverage For coverage area and sprinkler placement, refer to NFPA 13 or applicable standards. Job/Owner Engineer System No. Spec Section Location Paragraph Contractor Approved Submitted By Date Date victaulic.com I Sprinklers I FireLock® I K5.6, V36 I Publication 40.64 40.64 3127 Rev.J Updated 6/2014 ©2014 Victaulic Company.All rights reserved. 1 ictaulic victaulic.com I Sprinklers I FireLock® K5.6, V36 I Publication 40.64 Material Specifications: Accessories • Deflector: Brass per UNS C22000 or Stainless Steel per Installation Wrench: UNS S30400 Model V36 Open End and Recessed Wrenches fit all Bulb: Glass with glycerin solution V36 Series frames. Bulb Nominal Diameter: Sprinkler Finishes: LiStandard: 5.0 mm ❑ Plain brass Quick Response: 3.0 mm Chrome plated White painted3 Split Spacer: Stainless steel per UNS S30300 Flat black painted3 Load Screw: Brass per UNS C36000 Custom painted3 Pip Cap: Stainless steel per UNS S30300 El Proprietary Nickel Teflon2 Coated3 VC-2504 Spring Seal Assembly: Teflon2 coated Beryllium nickel 155, 200, 286 SR Only: alloy and stainless steel per UNS S30300 ❑ Wax3 Frame: Die cast brass For cabinets and other accessories refer to separate Outer Tube: Galvanized steel pipe sheet. 2 Teflon is a registered trademark of Dupont Co. Inner Tube: Stainless steel per UNS S30400 3 UL Listed for corrosion resistance. 4 UL Listed and FM Approved for corrosion resistance. Escutcheon/Plate: 1010 - 1018 mild steel and stainless steel NOTE:Weather resistant escutcheon available upon request. Torsion Spring: Stainless Steel Wire • 40.64 3127 Rev.J Updated 6/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 2 'ct:2iulic° victaulic.com I Sprinklers I FireLock® I K5.6, V36 I Publication 40.64 • " Approvals/Listings: APPROVALS/LISTINGS Model V3610 V3610 V3609 V3609 Orifice Size(inches) Y2 3h Th f/z Orifice Size(mm) 13 13 13 13 Nominal K Factor Imperial 5.6 5.6 5.6 5.6 Nominal K Factor S.l 5 8.1 8.1 8.1 8.1 Response Quick Quick Standard Standard Deflector Type Horizontal Sidewall Recessed Horizontal Horizontal Sidewall Recessed Horizontal Sidewall Sidewall Approved Temperature Ratings F°/C° 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C cUlus 6 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 286°F/141°C 286°F/141°C 286°F1141°C 286°F/141°C 135°F/57°C135°F/57°C 135°F/57°C 135°F/57°C FM 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 286°F/141°C 286°F/141°C 5 For K-Factor when pressure is measured in Bar,multiply S.I.units by 10. 6 Light Hazard Only-Listed for light hazard only with deflector from 4"—12"below the ceiling. Note:Listings and approval as of printing.Temperatures approved for V3609 and V3610 up to 48"length for cULus and 36"for FM. Dimensions: NOTE:The"A"dimension of a dry sprinkler,which extends into a freezer from a wet piping system,must take into account the wall or ceiling thickness of the freezer.See IMPORTANT INSTALLATION INFORMATION later in this document. A. (Min. ,4�ti" Escutcheon ' 1'NGT I"NPT / __-__1 , �k L: -_: Tee WlIsame lu.Min Dia. HoleinWxll 1'h" n. Tee WlttSame Holee in Wallall 3"Do. outlet size as 3"Min. outlet size as sprinkler thread 44'Max. sprinkler thread size. ', size. 4, See"Important See"Important Installation Installation Flush Information",later Sleeve&Skirt Information",later in this document in this document I.NPT (Min.13/41 11/2"Min.Dia. Wall Cup if- __ Hole in Wall I Collar - IMln.1A") __I r NFT 1'NIT �• __ �= I FL t imp, r�e ��`e ,Isprinkler thread ! ' ! uc Escutcheon } z"Min.Dia. __ __ Tee with same Hole in Wall [ } size. outlet size as 1%"Min.y Tee with same zsss"� See"Im"Important I sprinkler thread \ z'h"Mas. in outlet size as Installation (Min.OT 515 Max. size. I sprinkler thread Information",later size. Plain Barrel Extended See"Important Recessed in this document Installation See"Important ter Installation lin this document in this document Information",later in this document Deflector to ceiling distance 4-12"/102-305 mm for all configurations shown above. 40.64 3127 Rev.J Updated 6/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 3 .ctaulic° Bulletin 016 Rev, H Model DH56 HSW co e lima di Model DH56 HSW Recessed CD 5 RModel DH56 HSW Concealedo Quick Response, zi Extended Coverage Dry Sprinklers For coverages up to 28 feet wide and 10 feet long('). 250 psi (17,2 bar) rated. Features: 1. Coverage for long and narrow spaces such as hallways, ' : corridors, decks and rooms up to 28 feet wide and 10 S,. feet long.(') 2. Deflector to ceiling dimensions are: 4" (102mm)min.to 12" (305mm)max. DH56 HSW(See Fig.4) 3. Minimum spacing between sprinklers 16 feet(4.9m).(1) 4. Polyester Coated or Electroless Nickel PTFE (Teflon®) ,� „ Plated Corrosion Resistant Sprinklers. *Concealed Sprinkler is not corrosion resistance. 5. UL Listed for extended coverage,light hazard applications. r 6. 5.6 K thit \ 7. Sprinkler is approved for f, 250 psi (17,2 bar)applications. 8. Quick response performance. 9. 1" (13mm)adjustment of escutcheon and cover. DH56 HSW/HB(See Fig.5) 10.Concealed cover plate can prevent the sprinkler from being used for unintended purposes.No exposed thermal element ~. with the concealed version. 11.Push-on/thread-off sturdy convenient escutcheon for recessed and cover for concealed. 12.Factory assembled sprinkler&cup,shipped complete with bulb protector for concealed and FP recessed versions. 13.Sprinkler & cup assembly and escutcheon or cover are separately packaged. DH56 HSW FP Recessed (See Fig.6) 14.Available in a variety of plated and painted finishes t'►See Fig. 9. Approval Organizations 1. Listed by Underwriters Laboratories Inc. and UL certified for Canada(cULus) ,-- 2. NYC MEA 258-93-E Patents DH56 HSW Concealed US Patent No. 7,841,418 Other Patents Pending with SWC coverplate(See Fig. 7) The SWC cover plate and FP recessed escutcheons have Products Description 1/2" adjustment. The SWC cover plate is attached with 135 The Model DH56 are quick response extended cover- & 165 degree solder. In the event of a fire the rising ambient age sidewall dry sprinklers for use in light hazard applica- temperature melts the solder and the cover plate is ejected tions. The Model DH56 dry sprinkler with SWC cover plate away by springs exposing the 3mm frangible glass bulb. is a concealed sprinkler that uses Reliable's push on/thread The use of a 3mm bulb allows quick response which enables off sidewall cover.This sprinkler has the cup factory mounted the sprinkler to apply water to a fire sooner than standard and is shipped with a bulb protector that protects the 3mm response sprinklers of the same temperature rating. frangible glass bulb during shipping and post installation fin- Model DH56 dry sprinklers are intended for use in dry ishing operations. The DH56 can be combined in the field and preaction systems to protect areas subjected to freez- with the FP Escutcheon to make a recessed dry sprinkler. ing temperatures and unheated portions inside and outside buildings. See Fig. 1 for guidelines on using dry sprinklers in "DuPont Registered Trademark wet systems. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 • Environments wherein dry sprinklers are employed can DH56 HSW Recessed with FP Escutcheon be corrosive. For this reason, Model DH56 dry sprinklers To install the DH56 HSW dry sprinkler with the FP Escutch- have a special wax fillet placed in the gap between the eon as a recessed sprinkler cut a 25/8" diameter hole in the cup that supports the bulb and the wrenching boss. This wall as shown in Fig.6. Temporarily remove the plastic pro- wax will not interfere with the operation of the sprinkler, and tective cap, and then use the Model XLO2 wrench' (see it prevents contaminants from entering the internal portion Fig. 2)to tighten the sprinkler until it is secured in the sprin- of the drop nipple. The wax must not be removed. kler fitting. Note:The Model XLO2 wrench has a notch in it to accommodate the deflector top. This wrench can only Application be inserted one way. Care must be taken not to damage The Model DH56 is a horizontal sidewall dry sprinkler the deflector during tightening. Apply a Teflon* based seal- intended for installation in light hazard occupancies in ac- ant to the sprinkler threads before installing in the sprinkler. cordance with NFPA 13. These sprinklers are designed to It is recommended that the sprinkler be protected during provide fire protection in long and narrow spaces such as plastering and painting operations by reinstalling the plastic hallways, corridors, decks and rooms up to 28 feet (8,5m) protective cap. Installation is completed by removing the wide and 10 feet(3m)long. They are rated for 250 psi(17,2 protective cap and inserting the push-on escutcheon. Turn bar) and can be mounted between 4 and 12 inches (102 clockwise to adjust the escutcheon against the wall. and 305mm)down from the ceiling. DH56 HSW Concealed with SWC Cover Plate General Installation Instructions To install the DH56 HSW dry sprinkler with the SWC cover- Model DH56 dry sprinklers must be installed only in stan- plate as a concealed sprinkler, cut a 21/8"diameter hole into dard (ANSI B 16.3 class 150 and ANSI B 16.4 class 125) the wall as shown in Fig. 7. Temporarily remove the plastic pipe tees in the horizontal position,even at branch line ends. protective cap, and then use the Model XLO2 wrench' (see They should not be installed into elbows or pipe couplings Fig. 2)to tighten the sprinkler until it is secured in the sprin- located on drop nipples to the sprinklers. For these and kler fitting. Note:The Model XLO2 wrench has a notch in it other fittings including CPVC, the dry sprinkler should be to accommodate the deflector top. This wrench can only installed into a fitting to allow protrusion into the fitting in ac- be inserted one way. Care must be taken not to damage cordance with the diagrams. The "A" dimension of the dry the deflector during tightening. Apply a Teflon* based seal- sprinkler, which extends into a freezing zone from wet pipe ant to the sprinkler threads before installing in the sprinkler. systems, should be selected to provide, as a minimum, the It is recommended that the sprinkler be protected during specified lengths in inches shown in Fig. 1. plastering and painting operations by reinstalling the plastic Caution: protective cap. Installation is completed by removing the Do not install Model DH56 HSW Dry sprinklers into CPVC protective cap and inserting the coverplate. Coverplate as- adapter fittings or tees that have an internal obstruction. semblies provide 1/2" (13mm) of adjustment. Final adjust- This will damage the sprinkler and /or the fitting. Refer to ment is made by turning the coverplate clockwise until the Fig. 8 skirt flange makes full contact with the wall surface. Cover DH56 HSW removal requires turning in the counter-clockwise direction. Concealed coverplate assemblies are listed only for use To install the DH56 HSW dry sprinkler cut a 278" diameter with specific sprinklers.The use of any other concealed wall hole in the wall as shown in Fig. 4. Use the Model F3 instal- sprinkler or the use of the SWC coverplate on any sprinkler lation wrench (see Fig. 3)on the square boss to tighten the with which it is not specifically listed will void all guarantees, sprinkler until it is secured in the sprinkler fitting'. Apply a warranties, listings and approvals. Teflon* based sealant to the sprinkler threads before install- Note: DH56 and DH56 Recessed Sprinklers have orange ing in the sprinkler. Installation is completed by removing bulb protectors to minimize bulb damage during shipping, the orange glass bulb-protector and assembling the slip-on handling, and installation. REMOVE THIS PROTECTION AT escutcheon to the sprinkler's can. THE TIME THE SPRINKLER SYSTEM IS PLACED IN SER- DH56 HSW/HB VICE FOR FIRE PROTECTION. Removal of the protectors To install the DH56 HSW/HB dry sprinkler cut a 21/2" di- before this time may leave the bulb vulnerable to damage. ameter hole in the wall as shown in Fig. 5. Use the Model RASCO wrenches are designed to install sprinklers when F3 installation wrench (see Fig. 3) on the square boss to covers are in place. REMOVE PROTECTORS BY UNDO tighten the sprinkler until it is secured in the sprinkler fitting'. ING THE CLASP BY HAND. DO NOT USE TOOLS TO RE Apply a Teflon* based sealant to the sprinkler threads be MOVE THE PROTECTORS. fore installing in the sprinkler. Installation is completed by removing the orange glass bulb-protector and assembling the slip-on escutcheon to the sprinkler's can. ' Installation Wrenches Throughout this technical bulletin,Reliable has specified specific installation wrenches for use on each version of our sprinklers,A pipe wrench may also be used to install a dry sprinkler provided that it only interfaces with the steel outer tube of the assembly(Item#8 on fig 10).Keep in mind that a pipe wrench will incorporate a large amount of toraue into the final assembly.This toraue will have to be matched or exceeded upon the sprinkler's removal at a later date. *DuPont Registered Trademark 2. Technical Data: Maintenance • Temperature Sprinkler Model DH56 Quick Response Dry Sprinklers should be in- K Factor RatingMaximum spected and the sprinkler system maintained in accordance Thread Identification p P Y ent Size Ameratu Number with NFPA 25. Do not remove the factory applied thermally SWC US Metric Sprinkler Cover Temperature (SIN) sensitive wax fillet between the bulb supporting cup and the 155°F 135°F 100°F wrenching boss. Do not replace this wax with a substitute (68°C) (57°C) (38°C) substance. An alternate substance may interfere with proper 175°F 165°F 150°F operation of the sprinkler. Do not clean sprinklers with soap 5.6 80 1" (79°C) (74°C) (66°C) RA1664 and water, ammonia or any other cleaning fluids. Remove 200°F 165°F 150°F dust by using a soft brush or gentle vacuuming. Remove any (93°C) (74°C) (66°C) sprinkler which has been painted(other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or Coverage Area operated sprinklers. Prior to installation, sprinklers should be Maximum Coverage Flow Rate Pressure maintained in their original cartons and packaging until used Area Width x Length gpm(L/min) psi(bar) to minimize the potential for damage to sprinklers that would ft x ft(m x m) 28 x 8(88,,5 x 2,4) 23(87,1) 16.9(1,2) cause improper operation or non-operation. 28 x 10(8,5 x 3) 28(106) 25(1,7) Model DH56 Quick Response Approval Type: Extended Coverage Horizontal • Quick Response, Extended Coverage. Sidewall Dry Sprinkler Specification • Approved for installation in accordance with NFPA 13 Sprinklers shall be a [quick response- cULus Listed] ex- for light hazard occupancies. tended coverage horizontal sidewall sprinkler for light hazard occupancies. Sprinklers to be of bronze frame construction Step 1 with a special deflector capable of providing a discharge over a coverage area of 28 ft. (8,5m) wide, and 10 ft. (3m) long CS horizontal throw.Water seal assembly shall consist of a Teflon* coated Belleville spring washer. Installation shall permit sprin- kler deflectors to be positioned 4" (102mm)to 12" (305mm) 4 below the ceiling. Sprinklers shall have a nominal K-factor Step 2 of 5.6 (80), and 1" NPT thread. Sprinkler temperature rating >. .a; shall be [155°F(68°C)] and [200°F (93°C)]. Rated working . pressure shall be 250 psi (17.2 bar). Standard finish: [white] .111.11 [chrome][bronze][Special finish- specify]. Quick response i extended coverage horizontal sidewall dry sprinklers shall be Reliable Model DH56,SIN RA1664(Bulletin 016). Step 3 For recessed EC horizontal sidewall sprinklers: Replace "horizontal sidewall"with"recessed horizontal sidewall." Add: Ol.`: (1)Recessed escutcheon assembly shall be a two-piece es- ' - cutcheon of push-on and thread off design with 1" (13mm) Y adjustment.Standard finish shall.be chrome,white and brass. 4 Quick response recessed horizontal sidewall sprinklers shall Fig.2-XL02 Wrench be Reliable Model DH56, SIN RA1664(Bulletin 016). For concealed EC horizontal sidewall sprinklers: Replace :- ,, "horizontal sidewall" with "concealed horizontal sidewall." ''*"" Add: Cover plate assembly shall consist of a brass cover ` plate and copper alloy retainer flange. Method of attaching .. '" the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a 1" (13mm) cover plate adjust- ment. Cover plate temperature rating shall be 135°F (57°C) . for 155°F (68°C) dry sprinkler and 165°F (74°C) for 200°F (93°C) dry sprinkler. A bulb protector shall be provided and factory installed inside the sprinkler cup to protect the glass bulb from damage, which could occur during construction iir;.:1111, before the cover plate is installed.Standard cover plate finish: [white] [Custom Color- specify]. Quick response extended Fig.3-F3 Wrench coverage concealed horizontal sidewall dry sprinklers shall *DuPont Registered Trademark be Reliable Model DH56,SIN RA1664(Bulletin 016). 4. Ordering Information Installation Wrench' Specify: Model XLO2 Sprinkler Wrench (Recessed & Concealed) 1. Sprinkler Type (select one): Model F3 Sprinkler Wrench (a)Model DH56 Dry EC HSW Note: A leak tight 1" NPT sprinkler joint can be obtained (b)Model DH56 Dry EC HSW/HB with a torque of 20-30 ft-lbs (27.1 - 40.7 N-m). Do not (c)Model DH56 Dry Recessed EC HSW/FP tighten sprinklers over maximum recommended torque. (d)Model DH56 Dry Concealed EC HSW It may cause leakage or impairment of the sprinklers. 2. Sprinkler Temperature Rating. Escutcheon Data: 3. Sprinkler Finish. 4. Cover Plate/Escutcheon Finish. FP cup/escutcheon assembly-1/2" (13mm) adjustment 5. Length: "A" Dimension (face of tee to face of ceiling or Finishes (1) wall) in 1/4" (6mm) increments. Standard Finishes(1) Notes: Sprinkler Escutcheon Cover Plate 1. The "A" dimension is based on a nominally gauged pipe White or Black Polyester(2) Brass(3) thread "make-up" of 0.600" (15mm) per ANSI B2,1 [71 Chrome White White threads approximately]. Bronze Chrome 2. All platings and paintings are decorative and intended for interior use. Special Application Finishes Sprinkler HSW/HSW HB UL Listing CategoryEscutcheons Sprinklers, Automatic and Open. Electroless Nickel PTFE(Teflon®)*(2( Electroless Nickel PTFE(Teflon®)* (1)Quick Response Sprinklers. � Other colors and finishes are available. Consult factory for details. p p (2) cULus listed Corrosion Resistant (3) Not available for HB escutcheons. Note:Paint or any other coatings applied over the factory finish will void all approvals and warranties. 16' [4.9m] Minimum Spacing 28' [8.5m] Maximum Spacing MODEL DH56 DRY SPRINKLER *.4* WALL F Ot .i 4" [100mm] min.From Ceiling 12" [305mm] max. From Ceiling 28' [8.5m] 10' [3m] 016FG09A \\✓/ Fig.9 ' Installation Wrenches: Throughout this technical bulletin,Reliable has specified specific installation wrenches for use on each version of our sprinklers.A pipe wrench may also be used to install a dry sprinkler provided that it only interferes with the steel outer tube of the assembly(item#8 on fig 16).Keep in mind that a pipe wrench will incorporate a large amount of torque into the final assembly.This torque will have to be matched or exceeded upon the sprinkler removal at a later date. *DuPont Registered Trademark 8. Jet Fire Protection 1935 Silverton Rd. N.E. Salem, Oregon 97301 Jet Fire Protection 1935 Silverton Rd. N.E. Salem, Oregon 97301