Loading...
Plans BU P2017 - 00231 L_ _J [Inc ni= - v , m , ryr0 � �mO OOlrIS ses."----OFFICE COPY Tigard, Oregon 97223-8692 I--'a ` CITY OP TIGARD (503) 244-0552 7337 o O Oregon h APProv ) e�b 12 i�i a- OTC: ) Permit#: LCPoG l 7 —co a-3 Address: 7337 S w Tec h re h'te r n I Suite#: By: J r Date: g • 1 6 - )� Code Analysis Sheet Index BASED ON THE 2012 INTERNATIONAL BUILDING CODE (IBC) WITH 2014 OREGON STRUCTURAL AND SPECIALTY CODE AMENDMENTS AO.1 COVER SHEET AND SITE PLAN A2.1 FLOOR PLAN OCCUPANCY AND CONSTRUCTION PER OSSC 304.1, 306.2, 311.2 AND 602.3 ASSUMED OCCUPANCY: B/S1 NON-SEPARATED USE BETWEEN: B/S1 OCCUPANCIES, PER OSSC SECTION 302.1 CONSTRUCTION TYPE: III-B BUILDING HEIGHT AND AREA PER OSSC TABLE 503 Deferred Submittals �5���""' Alb � ALLOWABLE AREA: 51: 17,500 SF ALLOWABLE HEIGHT: 2 STORIES DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BEOs W L ,`I Ei a R.305. , 1,ACTUAL BUILDING AREA: 19,196 SF SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN 1 I ` • ACTUAL HEIGHT: 1 STORY RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD ` .11.1, . .. THEM TO THE BUILDING OFFICIAL WITH A NOTATION INDICATING AREA MODIFICATION PER OSSC 506 THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN ty,, OF O0 REVIEWED AND BEEN FOUND TO BE IN GENERAL CONFORMANCE TO Aa=At+[Atlf/100]+[Atls/100] THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL ITEMS — — — — - _ _ I At=12,000sf, Is=300 sprinkled one story, If=100[(F/P)-0.25](W/30), SHALL NOT BE INSTALLED UNTIL THE DESIGN AND SUBMITTAL — — F=355 lineal feet, P=710 lineal feet, W=30, DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING OFFICIAL. f, If=100[(612/612)-0.25](30/30) = .75, si Client Aa=17500+[17500x.75]+[17500x300/100] NOTE: NOTE: SUBMIT SHOP DRAWINGS FOR REVIEW OF DESIGN A0=17500+13125+52500=83,125 SF INTENT COMPLIANCE PRIOR TO FABRICATION OF THE FOLLOWING: i '� I McCormack FIRE-RESISTANCE RATING REQUIREMENTS PER IBC TABLE 602 1. ELECTRICAL ,i I Properties STRUCTURAL FRAME: 0 HR. EXTERIOR BEARING WALLS: 2 HR. _ bi Existing Building B EXTERIOR NON-BEARING WALLS: 0 HR. INTERIOR NON-BEARING WALLS: 0 HR. ;i I FLOOR CONSTRUCTION: 0 HR. General Notes p ? I I FIRE PROTECTION: BUILDING IS EQUIPPED WITH AN AUTOMATIC ESFR FIRE PROTECTION SYSTEM AND AUTOMATIC SMOKE DETECTION A. VERIFY AND CONFIRM ALL DIMENSIONS AND CONDITIONS 7190 SW Sandburg St. THROUGHOUT IN ACCORDANCE WITH OSSC 903.3.1.1 B. `,k Tigard, Oregon 97223 B. NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO START �q -,..--I r_,_�� OF WORK. •:••J v--- FLAME SPREAD INDEX: NOT MORE THAN 25 C. ALL HARDWARE IN ACCORDANCE WITH ANSI 117.1. ���� — — — Project: SMOKE DEVELOPED INDEX: NOT MORE THAN 450 D. PROVIDE (1) APPROVED FIRE EXTINGUISHER WITH RATING OF NOT LESS THAN 2-A: 108 FOR EACH 3,000 SQ.FT. OF FLOOR T.I. for OCCUPANCY REQUIREMENTS AREA TRAVEL FROM ANY PORTION OF BUILDING NOT TO I I L\ B OCCUPANCY: COMMON PATH OF EGRESS TRAVEL DISTANCE DOES NOT EXCEED 100'-0" PER OSSC SECTION 1014.3 EXCEED 75'. I I EXIT ACCESS TRAVEL DISTANCE DOES NOT EXCEED 300'-0" PER OSSC SECTION 1016.1 E. 100% SPRINKLERING TO BE MAINTAINED THROUGHOUT IN CravenSpeed ;•I ACCORDANCE WITH N.F.P.A. PAMPHLET #13. Si OCCUPANCY: COMMON PATH OF EGRESS TRAVEL DISTANCE DOES NOT EXCEED 100'-0" PER OSSC SECTION 1014.3 F. PROVIDE SIGN AT MAIN EXIT DOOR PER IBC 1008.1.8.3, 2.2 Q EXIT ACCESS TRAVEL DISTANCE DOES NOT EXCEED 250'-0" PER OSSC SECTION 1016.1 STATING "THIS DOOR MUST REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED". I I I I I p EMERGENCY LIGHTING: IN THE EVENT OF POWER SUPPLY FAILURE, AN EMERGENCY ELECTRICAL SYSTEM SHALL G. ALL MODIFIED WALLS TO RECEIVE LEVEL 4 FINISH : (1) COAT �, N 7337 SW Tech Center Dr. AUTOMATICALLY ILLUMINATE THE PORTION. OF THE EXTERIOR EXIT DISCHARGE IMMEDIATELY PRIMER, (2) COATS ACRYLIC LATEX; LEVEL OF GYPSUM BOARD .IIiIRlII�I. Tigard, Oregon ADJACENT TO EXIT DISCHARGE DOORWAYS IN BUILDINGS REQUIRED TO HAVE TWO OR MORE FINISH TO BE PER ASTM C840. EXITS WITH THE EXIT ILLUMINATION SUPPLEMENTED WITH AN EMERGENCY POWER SUPPLY IIP • CAPABLE OF PROVIDING POWER FOR A DURATION OF NOT LESS THAN 90 MINUTES PER OSSC H. NEW CARPET, VCT, RUBBER BASE AND PAINT AT OFFICE AREA • co SECTION 1006.3. ONLY. I I c i Sheet Title: SCOPE OF WORK: INTERIOR REMODEL: REMOVAL OF WALLS, DOORS, RELITES AND FRAMES; ADDITION OF ONE I ! - ��� Cover Sheet PAIR 3'x7' DOORS, NEW FLOORING AND PAINT THROUGHOUT OFFICE. a I I I Existin• Buil•in• A and PLUMBING FIXTURES I I OCCUPANT LOAD PER OSSC TABLE 2902.1 :' Site Plan B OCCUPANCY: 3,208 SF/100 = 32 PERSONS 16 MALE, 16 FEMALE Keynotes WATER CLOSETS: 1:25 FOR FIRST 50 Y 01? LAVATORIES: 1:40 FOR THE FIRST 80 1. EXISTING ACCESSIBLE PARKING, ACCESS AISLE AND SIGNAGE . �=/� O S OCCUPANCY: 5,792 SF/500 = 12 PERSONS I I 'M~�~' 6 MALE, 6 FEMALE Area of Work I WATER CLOSETS: 1: 100 A �� I ' Revisions: LAVATORIES: 1: 100 REQUIRED PROVIDED I I / 4rti ' LAVATORIES I I MALE 1 1 FEMALE 1 1 WATER CLOSETS �v MALE 1 1 — — •-7 FEMALE 1 1 — URINALS MALE 0 1 . SW Tech Center Drive SINKS 0 1 I- iMILOREN1 DESIGN GROUP, P.0.• 2017, ALL RIGHTS RESERVED Site Plan THESE DRAWINGS ARE THE PROPERTY OF MILDREN DESIGN P.C., AND E mir No Scale NOT TO SE USEDOOR REPRODUCED IN ANY MANNER, EXCEPT WITH THE PRIOR WRITTEN PERMISSION OF MILDREN DESIGN GROUP, P.C. OFFICE COPY Date: 14 August 2017 Drawn by: Checked by: CITY OF TIGARD BK WEM Approved by Planning g Date: I I & / I -i Job Number: 117124 Initials: Y11 'b Sheet Permit Submittal - August 2017 A0. 1 Demolition Keynotes 0- 31. REMOVE WALL, DOOR, RELITE AND FRAMES heles "" "--- 32. REMOVE PORTION OF WALL "" " '' MILDREN DESIGN GROUP, P.0 ARCHITECTURE • SPACE PLANNIN( 7650 S.W. Beveland, Suite 120 Door Schedule Tigard, Oregon 97223-8692 NOMINAL SIZE DOOR FRAME (503) 244-0552 MARK WIDTH HEIGHT THICK Type MAT'L FINISH MAT'L FINISH GLAZING HRDW. REMARKS Keynotes a" O © © 4 © 101 6 –0 ' 7 –01 3/4" A HM P HM P TEMP 1 -- l PROVIDE PAIR 3'x7' HM DOORS IN EXISTING WALL 2. PATCH CEILING AT REMOVED WALLS 3. NEW CARPET AND 4" RUBBER BASE THIS PORTION OF 100 —0" OFFICE / LEGEND 4. NEW VCT AND 4" RUBBER BASE THIS PORTION OF OFFICE HM HOLLOW METAL 5. PROVIDE VERTICAL GRAB BAR PER DETAIL 1/A2.1 P PAINT -- A \ C B, — T 7 C Door Hardware B, i i I u GROUP 1 L - - - - - - - - - - - - - - - - - -I 3 PAIR BUTTS i LATCHSET 2 CLOSERS COORDINATOR t�/� ASTRAGAL c`• - ARC GASKET Finish Schedule ( s/ KICKPLATES (EACH SIDE) 'N. " KICKSTAND HOLD OPEN (1 EACH DOOR) CO ROOM NAME 305. ! Floor Finish - A488 � 11/ 1. ,f� E I � R. . A. CARPET I' �' �� B. VINYL COMPOSITION TILE eirPb WAREHOUSE I X. EXISTING TO REMAIN OF 0��' EDoor Type BaseXXXXX 5791.51 S.F. /500 = 17.58 I Tempered Relite 4" RUBBER BASE Client: 5:EXITS 1 IX. EXISTING TO REMAIN B - ❑ ❑ ❑ EXIT TRAVEL DISTANCE=110•73' J _ ��� McCormack / Wall Finish Properties ernes — N X. EXISTING TO REMAIN • © ,� Ceiling Finish m MEN X. EXISTING TO REMAIN E � N/ 7190 SW Sandburg St. XXXXX 18.76 S.F. 0 ' I� A 18" Tall Kickplate „ Tigard, Oregon 97223 EXEMPT / „eiling Heig ht D X. EXISTING TO REMAIN Project: WOMEN E T. I. for xxxxx OT EXIST NG ASTIC XEMP S.F. , O LAMINATE PLWAINSCOT AT CravenSpeed EXEMPT / ®' THESE TWO WALLS ONLY p ..._, , O I / — VERTICAL GRAB BAR 1 ® _ 0 1 ill / BREAK ROOM E Room Symbol Legend t drIOP OF' CEB4XXX 272.46 S.F. I A4 X �B 4X - /75 78.16 ROOM NAME 1:9.4 . S.F •0, 16 .4• S.F. �� B:EXITS 1 �•_a' - 7337 SW Tech Center Dr. /100 = .59`j 700 = 7•.43 / OFFICE EXISTING ROOM D /1 B• XI T. 7/ B: ITS E . I ROOM AREA LOAD Q Tigard, Oregon E IT TR' L D ANC •8_9' AREA/LOAD FINISH -- - -- - - -- — / y FACTOR �B4BB9�— ' '.' I. = = 0 XXX/100:2�_ �� I i � BT VCT � NUMBER OF B:2 E ITS il OCCUPANTS Sheet Title: D OCCUPANCY GROUP PER NUMBER OFAW ' Jr - Floor Plan ;L '' IO CONFERma EE E ®I I✓ OPEN O�I'IC �i rn " / 005 S :• ® i X 8643.49 !S.F. A1166..4 S 20 .07 :.F. /100 176'43 �� /'EO S 1.6 • B: 5(1TS73.+ II B:EXITS 11 I II EXISTING © , , / ACCESSIBLE TOILET EXISTING TOILET TISSUE DISPENSER ' I EXISTING GRAB BARS Revisions: (_k Floor Plan ( i Toilet Room Elevation Mr 2:1 R0., 0 2 4 8 16 Toilet Room Elevation 1 – floor mounted W.0 and wall mount lay existing add vertical MILDREN DESIGN GROUP, P.C., 2017, ALL RIGHTS RESERVED THESE DRAWINGS ARE THE PROPERTY OF MILDREN DESIGN GROUP, P.C., AND ARE NOT TO BE USED OR REPRODUCED IN ANY MANNER, EXCEPT WITH THE PRIOR WRITTEN PERMISSION OF MILDREN DESIGN GROUP, P.C. Date: 14 August 2017 Drawn by: Checked by: BK WEM Job Number: 117124 Sheet Permit Submittal - August 2017 A2. 1