Plans (14) i i 01 00 00 GENERAL DATA g. HARDWARE 23 00 00 HVAC : DESIGN/BUILD SPECIFICATIONS. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE 'rt., 1. FOR BIDDING PURPOSES,THE HVAC CONTRACTOR WILL ASSUME THAT EXISTING HVAC EQUIPMENT IS IN GENERAL REQUIREMENTS 3. FINISH FLOORING TO EXTEND UNDER ALL NEW CASEWORK. HVAC-BID PROCEDURE IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. eiji 4 $1; 1. ALL CONSTRUCTION WORK SHALL BE DONE IN COMPLIANCE WITH THE LATEST EDITION OF THE OREGON 4. PROVIDE A TRANSITION STRIP WHERE EVER TWO DIFFERENT FLOOR MATERIALS MEET 14.REQUIRED IN DIVISION 15,PROVIDE MONITORING OF HVAC EQUIPMENT PER CODE. � 15.REMOVE ALL UNUSED DATA AND POWER BOXES AND INFILL WITH GYP BOARD. EXCEPTION-UNUSED DATA 1, #3082 STRUCTURAL SPECIALTY CODE,AND ALL OTHER STATE OR LOCAL CODE REQUIREMENTS THAT APPLY. 5. PROVIDE SCHLUTER METAL TRIM AT ALL EXPOSED EDGES OF TILE(EXCEPT AT BULLNOSED EDGE)OF TILE PROPER WORKING ORDER. BOXES UNDER WINDOW SILLS TO REMAIN. ALL BLANK COVER PLATES TO BE BUILDING STANDARD FINISH. 2. VERIFY ALL DIMENSIONS AND CONDITIONS SHOWN ON DRAWINGS AND AT THE EXISTING BUILDING AND (CERAMIC,QUARRY OR PORCELAIN) 2. INVENTORY EXISTING H.V.A.C.ROOFTOP UNITS AND SUBMIT TO ARCHITECT A CONDITIONS REPORT OF EACH 16.REMOVE ALL UNUSED LOW VOLTAGE WIRING(TELEPHONE AND DATA)FROM THE RECEPTACLE TO THE TENANT IMPROVEMENT for MARTIN W. HANSON NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO STARTING THE WORK. UNIT 09 21 00 GYPSUM BOARD DISTRIBUTION BOARD.LEAVE PULL STRINGS FROM THE BOX TO THE SPACE ABOVE THE CEILING. A SECTION 3. CONTRACTOR AND ALL SUBCONTRACTORS SHALL PERFORM DUE DILIGENCE INSPECTION OF ALL EXISTING 3. LIST TONNAGE OF EACH UNIT. OF THE EXISITNG LOW VOLTAGE WIRE MAY BE LEFT IN LIEU OF A PULL STRING CONDITIONS PRIOR TO SUBMITTAL OF A PROPOSAL.SUBMITTAL OF A PROPOSAL SHALL BE CONSIDERED GENERAL CONFIRMATION THAT SUCH INSPECTION HAS BEEN MADE,AND NO FURTHER COMPENSATION SHALL BE DUE 4. ALL GYPSUM BOARD WALLS: ONE LAYER 5/8"TYPE X GYPSUM WALLBOARD,EITHER AT RIGHT ANGLES OR HVAC-DESIGN PROCEDURE OFFICE LIGHTING pcc228 S 190 IA�KAMASOREGOTHE CONTRACTOR FOR CLAIMS ARISING AS A RESULT OF FAILURE TO PERFORM SUCH INSPECTION. PARALLEL TO FRAMING ON EACH SIDE OF METAL STUDS SPACED AT 24"O.C. FASTEN WITH 1"TYPE S USE EXISTING AND/OR NEW EQUIPMENT TO DESIGN MECHANICAL H.V.A.C.SYSTEM PER DESIGN STANDARDS 1. RE-LAMP EXISTING FLUORESCENT LIGHTS THROUGHOUT AS NEEDED.DRYWALL SCREWS 8"O.C.TO VERTICAL EDGES AND 12"O.C.TO TOP AND BOTTOM RUNNERS AND LISTED BELOW. ,� �} 4. BBY SUBMITTING THE A PROP ALU ONTIRACTOR AND D ALL SUBCONTRACTORS S CERTIFY TO COTHAT THEY HAVE THE WORK INTERMEDIATE STUDS. STAGGER ALL VERTICAL AND HORIZONTAL JOINTS 24"O.C.(OR ONE STUD SPACING), PRIOR TO AWARD OF CONSTRUCTION CONTRACT,H.V.A.C.CONTRACTOR SHALL SUBMIT TO ARCHITECT FOR 2. BALLASTS)LIGHTOFFICE FIXTURES-LITHONIA 2PM3N G B 3 32 181D MVOLT ADVANCE OR EQUAL.(NO SYLVANIA ,� EACH SIDE AND OPPOSITE SIDES.. PROJECT NARRATIVE op O� DESCRIBED OR REASONABLY IMPLIED IN THESE DOCUMENTS. THIS INCLUDES BUT MAY NOT BE LIMITED TO REVIEW AND APPROVAL A FULL DESIGN SCHEMATIC FOR THE TENANT SPACE INCLUDING BOTH EXTERIOR LIGHTING ALL MATERIALS AND INSTALLATION,DISPOSAL OF EXCESS MATERIALS(USEABLE FINISH MATERIALS SHALL BE 5. ALL OFFICE GYPSUM BOARD TO RECEIVE ONE TAPE COAT AND TWO FINISH COATS WITH SANDING BETWEEN NEW/RENOVATED WORK AND SYSTEMS UNTOUCHED BY THE TENANT IMPROVEMENT AS APPLICABLE. THIS PROJECT CONSISTS OF MINOR REMODELING TO LEFT IN THE TENANT SPACE AS DIRECTED BY PACTRUST),CLEANING AND ALL PREPARATION OF SUBSTRATE FINISH COATS. APPLY USG SHEETROCK BRAND FIRST COAT. PAINT AS INDICATED. INCLUDE THE FOLLOWING: 1. ENTRY LIGHTING AT RECESSED OPENINGS: LITHONIA LF6N,26DTT LAMP,F6OSA RELFECTOR.(EMERGENCY A RECENTLY RELINQUISHED SPACE SURFACES PRIOR TO INSTALLATION,AS WELL AS FINAL CLEAN UP. 6. ALL OTHER GYPSUM BOARD TO RECEIVE ONE TAPE COAT AND ONE FINISH COAT WITH SANDING AFTER FINISH a. DUCTING AND SIZES BATTERY PACK OPTION EL) FROM A ADJACENT TENANT. WORK INCLUDES BUT IS NOT BE LIMITED TO PROJ # 16280 5. IT IS THE INTENT OF THESE CONTRACT DOCUMENTS TO MATCH AND MAINTAIN EXISTING BUILDING COAT. PAINT AS INDICATED. 2. LITHONIA LIGHTING WST LED 1 10A700/40K SR4 MVOLT ELCW DDBXD.EXTERIOR EGRESS LIGHTING. DRYWALL/M ETAS STUDS, SUSPENDED CEILINGS, DOORS/FRAMES AND PAINTING. ALL STANDARDS FOR ALL EXISTING PRODUCTS AND SYSTEMS. UPON DISCOVERY OF A DISCREPANCY TO THIS b. SUPPLY AND RETURN LOCATIONS AND CFM AT EACH GRILL OR DIFUSER INTENTION,THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY. 7. IN FINISHED SPACES PURR-OUT BUILDING COLUMNS AND EXTERIOR WALLS WITH 5/8"GYPSUM BOARD OVER c. ROOF EQUIPMENT,SIZES AND LOCATIONS WORK TO COMPLY WITH THE CURRENT ADDITION OF ALL APPLICABLE CODES ANDr. METAL STUDS. REGULATIONS. rralllI 6. FURNISH ALL NEW MATERIALS EXCEPT WHERE SPECIFICALLY NOTED OTHERWISE. 8. PROVIDE ACOUSTIC GASKETS WHERE WALL INTERSECTS STOREFRONT. QUIETJOINT SHH WHERE WALL d. UNITS REQUIRING DUCTED SMOKE DETECTION r 1 RECEIVED 7. COORDINATE THE WORK OF ALL TRADES. PROVIDE CARPET'WALK-OFF MATS"TO PROTECT EXISTING MEETS MULLION AND QUIETJOINT SHG WHERE WALL MEETS GLAZING.COLOR SELECTED BY ARCHITECT. e. THERMOSTAT LOCATIONS AND ZONE/UNIT ASSOCIATED THEREWITH FSI CARPETS. 9. AT ALL EXISTING WALLS,REMOVE ALL NAILS,SCREWS,FASTENERS,ETC.LEFT BY PREVIOUS TENANT AND f. ANY SUPPLEMENTAL EXHAUST FANS OR SPECIAL SYSTEMS 8. ALL ROOF PENETRATIONS FROM ABANDONED EQUIPMENT TO BE REMOVED. PATCH AND REPAIR ROOF AND PATCH HOLES READY FOR PAINT. g. ZONE DIAGRAM WORK INCLUDED BUT PERFORMED UNDER SEP. PERMIT E"ll MAY 2 6 2016 ROOF MEMBRANE TO MATCH THE EXISTING ROOF. 10.REPAIR GYPSUM BOARD AT REMOVED ELECTRICAL RECEPTACLES OR DATA BOXES AND FINISH READY FOR M 9. ALL ROOF WORK TO BE PERFORMED BY PACTRUST APPROVED ROOFING COMPANIES. APPROVED PAINT HVAC DESIGN STANDARDS FIRE PROTECTION SPRINKLERING rW CITY OF TIGARD COMPANIES INCLUDE: 11.UPON REMOVAL OF WALL BASE,REMOVE RESIDUAL ADHESIVE AND PREP WALL TO PAINT READY CONDITION. THE FOLLOWING ARE MINIMUM DESIGN STANDARDS: HEATING,VENTILATION&AIR CONDITIONING WORK • Li BUILDING DIVISIO'� a. ARROW ROOFING, ALFONSO PEREZ (503)460-2767 WALL CONSTRUCTION MATERIALS 1. 350 SQUARE FOOT PER TON(UNLESS OTHERWISE APPROVED IN WRITING BY PACTRUST). ELECTRICAL WORK, BOTH LINE VOLTAGE AND LOW VOLTAGE a/ b. PACIFIC ROOFING, GUY BELT (503)640-3163 1. PROVIDE STUDS,TRACKS,BRACING,FASTENING AND OTHER ACCESSORIES NECESSARY FOR COMPLETE 2. ADDRESS LOADS BY SPECIFIC LOCATION AND USE,AS WELL AS CRITERIA PROVIDED TO PACTRUST BY c. GRIFFITH ROOFING, GREG STONE (503)643-1596 INSTALLATION. TENANT PRIOR TO CONSTRUCTION: 10.KEEP THE AREA OF WORK FREE OF GARBAGE AND DEBRIS ON A DAILY BASIS INCLUDING DOCK ACCESS 2. FRAMING MEMBERS SHALL HAVE THE STRUCTURAL PROPERTIES INDICATED WHERE PHYSICAL STRUCTURAL a. EXTERIOR EXPOSURE AREAS n AREAS AND COMMON AREA. FLOORS TO BE SWEPT OR VACUUMED DAILY. PROPERTIES ARE NOT INDICATED,THEY SHALL BE AS NECESSARY TO WITHSTAND ALL IMPOSED LIVE LOADS. b. INTERIOR AREAS,SIZE AND USE BUILDINGINFORMATION TENANT INFORMATION DESIGN FRAMING IN ACCORDANCE WITH AISI SG-673. p _ - O 11.PROVIDE ADEQUATE PROTECTION TO ALL EXISTING IMPROVEMENTS INCLUDING BUT NOT LIMITED TO c. CONFERENCE/TRAINING ROOMS OWNER: PACIFIC REALTY ASSOCIATES, L.P. TENANT: O COMMON CORRIDORS AND STAIRS,BUILDING ENTRANCES,SUITE ENTRANCES,ETC. THE CONTRACTOR WILL 3. COLD-FORMED FRAMING SHALL BE GALVANIZED METAL CONFORMING TO ASTM A446/A 446 M GRADE A(33000 d. COMPUTER/SERVER AND TELEPHONE ROOMS TO HAVE PROVISION FOR LOW AMBIENT OPERATION cn BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGES TO EXISTING IMPROVEMENTS DUE TO CONSTRUCTION PSI)G60. AND 24-HOUR USE.VERIFY NEED FOR A SEPARATE SPLIT SYSTEM TO MAINTAIN TEMPERATURE. 15350 SW SEQUOIA PKWY#300 ACTIVITIES. 4. PROVIDE THE LISTED GYPSUM BOARD PRODUCTS BY U.S.GYPSUM,GEORGIA PACIFIC,NATIONAL GYPSUM OR PORTLAND, ORE 97224 pCC228 Suite#190 12.PROVIDE TEMPORARY SANITARY FACILITIES. CONSTRUCTION WORKERS SHALL NOT USE BUILDING AN APPROVED EQUAL. 3. SYSTEM DESIGN CRITERIA-SIZE ZONES FOR 3-5 TON UNITS BASED ON USE&EXPOSURE CRITERIA. TYPE AREAS LOADS EXITS RESTROOM FACILITIES. PACKAGED OR SPLIT SYSTEM EQUIPMENT GREATER THAN 5 TONS SHALL BE SPLIT INTO MULTIPLE ZONES. 5. STANDARD GYPSUM BOARD SHALL BE TYPE'X',5/8"THICK WITH TAPERED EDGES CONFORMING TO ASTM VAV OR WATER SOURCE HEAT PUMP SYSTEMS GREATER THAN 3 TONS SHALL BE SPLIT INTO MULTIPLE (503)624-6300 (PHONE) B 4,778 SF 48 OCC 1 LA 7 13.STORAGE AND STAGING OF CONSTRUCTION MATERIALS SHALL BE LIMITED TO AREAS AS DESIGNATED AT C-36. ZONES. p-'N (503 624-7755(FAX) PRE-CONSTRUCTION MEETING. UNDER NO CIRCUMSTANCES SHALL BUILDING UTILITY AREAS OR ANY OTHER . N COMMON BUILDING AREA BE USED FOR STORAGE. 6. WATER RESISTANT GYPSUM BOARD SHALL BE 5/8"THICK WITH TAPERED EDGES. CONFORMING TO ASTM 4. ALL ENCLOSED ROOMS OR OFFICES TO HAVE DUCTED SUPPLY&RETURN GRILLES. • �CN C-630. 5. VACANT SPACE SHALL HAVE DEDICATED GAS SERVICE FOR FUTURE BUILD-OUT OR FREEZE PROTECTION. BLDG.#: PCC BLDG.#5 (pcc228) O O 14.KEEP THE ROOF FREE OF DEBRIS(I.E.NAILS,SCREWS,BOTTLES,ETC.)AT ALL TIMES. 7. AT TOILET ROOMS USE 5l8"USG FIBERROCK BRAND AQUATOUGH INTERIOR PANEL FROM FLOOR TO 48'A.F.F. `f7 6. UNITS: LENNOX,TRANE,YORK OR CARRIER-7 1/2-TON MAXIMUM UNIT SIZE. ANY UNIT IN EXCESS OF 7 1/2 jj 0/0l� 15.ALL DIMENSIONS ARE TO FACE OF GYPSUM BOARD UNLESS OTHERWISE NOTED. ON WALLS BEHIND OR ADJACENT TO PLUMBING FIXTURES. NO SUBSTITUTES.(EXCEPTION:EXCEPTION AT �� LOCATIONS TO RELIEVE PLASTIC LAMINATE OR TILE WAINSCOT.) TONS SHALL HAVE SPECIAL WRITTEN APPROVAL FROM PACTRUST. CONST.TYPE.: II-B F-1 ' ' 16.CONFIRM SIZES OF ALL OPENINGS REQUIRED FOR THE INSTALLATION OF STRUCTURAL,MECHANICAL, I.y W ELECTRICAL AND PLUMBING WORK PRIOR TO FRAMING OR CUTTING FOR INSTALLATION. 8. AT TILE WAINSCOT LOCATIONS INSTALL CEMENT BACKER BOARD W THICK WITH SQUARE,REINFORCED, 7. HVAC UNITS EQUAL TO OR GREATER THAN 5-TONS TO HAVE DUCT SMOKE DETECTORS AND BE CONNECTED T/J N(V TO A MONITORING STATION WITHIN THE BUILDING. 17.LEAVE THE PROJECT CLEAN AND READY FOR OCCUPANCY. SMOOTH EDGES. PROVIDE DUROCK BRAND CEMENT BOARD OR APPROVED EQUAL. THIS BUILDING HOUSES MULTIPLE SEPARATE TENANTS INCLUDING THIS TENANT. THE �I '3 ,---,--. 8. ROOF TOP UNITS SHALL BE PLACED 24'MINIMUM FROM ROOF EDGE TO CENTER OF UNIT. MULTIPLE UNITS V]a en en 9. INSTALL WATER-RESISTANT GYPSUM BOARD BEHIND WAINSCOT OF FRP,PLASTIC LAMINATE,ETC. EXISTING BUILDING ISA SINGLE STORY BUILDING OF 22,500 SF AND IS FULLY [y 18.CLEAN ADJACENT EXTERIOR AREA,I.E.WALKS,EXTERIOR GLASS,ETC. SHALL BE PLACED SYMMETRICALLY IN A LINE BASED ON LOAD CALCULATIONS BY STRUCTURAL ENGINEER. O O 19.PROVIDE"AS-BUILT'DRAWINGS OF THE WORK AT THE CONCLUSION OF CONSTRUCTION."AS-BUILT' 10.TRIM ACCESSORIES SHALL COMPLY WITH ASTM C-1047. SPRINKLERED. THERE IS FRONTAGE ON ALL FOUR SIDES OF AT LEAST 72 FEET.9. CURBS: 14"HIGH CURBS. ASSEMBLED AND LEVELED TO ROOF,ANCHORED TO STRUCTURAL MEMBERS v1 �� DRAWINGS MAY BE IN THE FORM OF TWO COPIES OF CONSTRUCTION DOCUMENTS MARKED-UP WITH RED 11.USE GEORGIA PACIFIC DENSGLAS GOLD ON EXTERIOR FACE OF EXTERIOR WALLS AND COAT WITH STO FINISH BELOW ROOFING. FP,a xi k PEN.DELIVER RECORD DRAWINGS TO THE ARCHITECT. COMPLETE OPERATION AND MAINTENANCE MANUALS SYSTEM. a. PROFESSIONALLY ROOF IN ALL CURBS AND PENETRATIONS BY PACTRUST APPROVED ROOF ALLOWABLE AREA IS UNLIMITED(OSSC 507.3) .---1C-1 o4 w SHALL BE PROVIDED FOR ALL MECHANICAL,ELECTRICAL AND PLUMBING EQUIPMENT.PACTRUST MAY HOLD WALL CONSTRUCTION EXECUTION CONTRACTOR. SEE DIVISION 1 GENERAL NOTES THIS PAGE. ))) CONTRACTOR'S FINAL PAYMENT UNTIL"AS-BUILT'DRAWINGS AND 0&M MANUALS HAVE BEEN RECEIVED I AND APPROVED. 1. FASTEN FRAMING MEMBERS TOGETHER BY WELDING OR BY USING SELF-DRILLING OR SELF-TAPPING b. UNIT MUST BE LEVEL,SEALED WITH NO AIR LEAKS AND COUNTER FLASHED. /-- SCREWS. WELDING SHALL CONFORM TO AWS D13 WELDING PROCEDURE. ELECTRODES AND SCREW 20.IT IS THE INTENT OF THE CONTRACT DOCUMENTS THAT THE CONTRACTOR PROVIDE A COMPLETE, c. CONDENSATE MUST BE TRAPPED AT UNIT. FUNCTIONING PROJECT INCLUDING ALL GENERAL,MECHANICAL AND ELECTRICAL CONSTRUCTION REQUIRED CONNECTIONSERIALSLIGHTERSHALL THANB18 REQUIREDGAND INDICATED IN THE DESIGN CALCULATIONS. DO NOT FIELD WELD MATERIALS GA. 10.SEISMICALLY ATTACH UNIT TO CURB IN CODE-APPROVED METHOD. TO FULFILL THAT INTENT. ALL ITEMS REQUIRED SHALL BE FURNISHED AND INSTALLED,REGARDLESS OF TO PORTLAND Cnanuam' L WHETHER OR NOT SHOWN ON THE DRAWINGS. 2. PROVIDE ACCURATELY ALIGNED RUNNERS AT TOP AND BOTTOM OF PARTITIONS. ANCHOR TRACKS AS 11.ALL GAS PIPING SHALL BE STANDARD BLACK STEEL PIPE WI SUPPORTS PER CODE. PIPING SHALL BE RUN Ewr"'"' 1-' 21.ITEMS OR WORK NOT TO BE FURNISHED OR ACCOMPLISHED BY CONTRACTOR ARE NOTED"N.I.C.". INDICATED IN THE DESIGN CALCULATIONS. BUTT WELD JOINTS IN TRACKS OR SPLICE WITH STUD INSERTS. INSIDE OF BUILDING W/LEAD FLASHINGS AT ROOF PENETRATIONS. LEAD ROOF JACKS TO BE SEALED AND rr- .. FASTENERS SHALL BE AT LEAST 3 INCHES FROM THE EDGE OF CONCRETE SLABS. CLAMPED(STAINLESS STEEL WORM GEAR). i • 1 o - ®/ 22."ALIGN"AS USED IN THESE DOCUMENTS,MEANS TO ALIGN THE FINISHED FACES OF ELEMENTS IN THE SAME . II I r i +s "-'- \ III 3. CUT STUDS SQUARE AND SET WITH FIRM BEARING AGAINST WEBS OF TOP AND BOTTOM TRACKS. POSITION 12.ALL EXISTING AND NEW GAS PIPING EXPOSED TO THE EXTERIOR TO BE PROTECTED FROM RUST AND - +' PLANE,EITHER IMMEDIATELY ADJACENT TO ONE ANOTHER OR ACROSS AN OPENING. '--I I • - 11 -� ' STUDS VERTICALLY IN TRACKS AND SPACE AS INDICATED IN DESIGN. DO NOT SPLICE STUDS. PROVIDE AT CORROSION WITH OIL BASED PAINT(COLOR GREY). I '-= / '"'^�' a 23.D0 NOT DISASSEMBLE SETS OF CONSTRUCTION DRAWINGS.DRAWINGS ARE INTERRELATED. LEAST TWO FULL HEIGHT KING STUDS AT DOORS AND OTHER OPENINGS 2 FEET WIDE OR LARGER. PROVIDE �� - I �� s4 N JACK STUDS OVER OPENINGS,AS NECESSARY,TO MAINTAIN INDICATED STUD SPACING. PROVIDE TRIPLE 13.LOW VOLTAGE IN SEALTITE CONDUIT FROM BELOW ROOF LINE DIRECT TO UNIT. DO NOT EXCEED BEND 1 _ _ _ 24.SUBMIT SAMPLES OR DRAW DOWNS FOR ALL FINISHES REQUESTED TO THE ARCHITECT OF RECORD WITHIN RADIUS OF MANUFACTURER'S GUIDELINE. j �`L-I-II �6 =' e "' �`^� U STUDS AT CORNERS,POSITIONED TO RECEIVE INTERIOR AND EXTERIOR FINISHES. FASTEN STUDS AT TOP ff�' TWO WEEKS OF PROJECT AWARD.PRODUCTS INSTALLED WITHOUT APPROVED SAMPLES ARE SUBJECT TO 1--�, / o O AND BOTTOM TRACKS BY WELDING OR SCREWING BOTH FLANGES TO THE TRACKS.PROVIDE LONG LEG 14.ECONOMIZER TO MEET CODE AND AS FOLLOWS: U 1 M REPLACEMENT AT CONTRACTOR COST. AN APPROVED SUBMITTAL DOES NOT CHANGE THE CONTRACTUAL 9 �� �'.' , , LL TRACK AT TOP OF WALL TO ALLOW FOR DEFLECTION WHERE WALL MEETS STRUCTURE ABOVE. . --- - -- - - u ^�' I-"- -- c�• S REQUIREMENT TO PROVIDE THE SPECIFIED ITEMS UNLESS SPECIFICALLY NOTED AS A SUBSTITUTION BY THE a. 6 TONS AND ABOVE MUST HAVE ECONOMIZER. - Q�� ^• - o _ L \ CONTRACTOR AND SPECIFICALLY APPROVED BY THE ARCHITECT AS SUCH.REPLACE SUCH PRODUCTS AS 4. INSTALL ALL INTERIOR AND EXTERIOR GYPSUM BOARD PRODUCTS AND ACCESSORIES AS REQUIRED FOR �"`"":: 1 �� t^1 _. -�` - t DIRECTED AT CONTRACTOR'S COST. THE PROJECT. b. BAROMETRIC RELIEF ON 5-7 1/2 TON UNITS. $ " ISI 1 - la I I \eft Ai, �, H 25.SUBMIT COMPLETE SHOP DRAWINGS FOR MILLWORK,SPECIAL SYSTEMS,MECHANICAL,ELECTRICAL AND 5. AT TOILET ROOMS TO RECEIVE SHEET VINYL FLOORING,INSTALL THE GYPSUM BOARD(OR AUQATOUGH) c. 8 TONS AND ABOVE MUST HAVE POWER EXHAUST. _�� S, 1 g I ° `r��r 1 1� �y PLUMBING SYSTEMS(INCLUDING FIRE PROTECTION SYSTEMS). SUBMIT A MINIMUM OF TWO COPIES OF ALL WITH 1/4"GAP BETWEEN THE BOARD AND THE FLOOR TO PREVENT WICKING. d. 1 1/2 THRU 4-TON OSA INTAKE WITH DAMPER. , -M a+it ' L I JI t iSHOP DRAWINGS FOR REVIEWANDAPPROVAL TOTHEARCHITECTOF RECORD.ARCHITECT WILL RETAIN ONE I I ' 1 1I- - E����� /�6. COMPLY WITH USG GYPSUM CONSTRUCTION HANDBOOKANDMANUFACTURER'S RECOMMENDATIONS. 15.ALL UNITS TtJ MEETOR EXCEED CURRENT ENERGY EFFICIENCY CODE REQUIREMENTS -� Y/ COPY AND ONE COPY WILL BE RETURNED TO THE CONTRACTOR. 7. FINISH QUALITY: 16.DROP CANS TO BE SAME SIZE AS CURB OPENING AND TO EXTENDED TO WITHIN 2'OF SUSPENDED CEIILING. 3 26.THE DESIGN OF FIRE PROTECTION SYSTEMS IS THE RESPONSIBILITY OF THE FIRE PROTECTION SYSTEMS -n 1 - - -- j `�•� - -� CONTRACTOR.ALL FIRE PROTECTION SYSTEMS SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER AREA PROCESS TRADE NOMENCLATURE MINIMUM 26 GAUGE FOR SUPPLY AIR. SEAL EDGES OF SUPPLY AIR. M LICENSED BY THE APPROPRIATE JURISDICTION FOR THE DESIGN OF THIS TYPE OF SYSTEM. COORDINATE17.DISTRIBUTION DUCTWORK: A .LL OFFICE/OTHER AREAS TAPE/2 FINISH COATS'/ SMOOTH FINISH TAPED r` INTERFACE WITH EXISTING BUILDING SYSTEMS AND WITH ARCHITECT. ALL SPRINKLER HEADS SHALL BE BUILDING LOCATION a. SPIRAL DUCT PERMITTED ONLY IF EXPOSED. CENTERED IN CEILING TILE(OR 2 x 2 MODULE OF A SECOND LOOK II TYPE OF CEILING TILE WHERE USG"FIRST COAT' •SAND AFTER TAPE/FINISH COAT(S) APPLICABLE). LOCATION OF THOSE IN GYPSUM BOARD CEILINGS SHALL BE PRE-APPROVED IN WRITING BY b. 26 GAUGE OR TO SMACNA STANDARDS WHERE DUCT IS CONCEALED ABOVE A CEILING. 8. FINISH EXPOSED INTERIOR GYPSUM BOARD WALLS AND CEILINGS SMOOTH STRAIGHT READY FOR FINISH AS THE ARCHITECT PRIOR TO INSTALLATION. SHOWN ON PLANS. c. WRAP CONCEALED SUPPLY DUCTWORK IN NON-CONDITIONED AND SEMI-CONDITIONED SPACE WITH LOCATION MAP Ze Q 27.COORDINATE ALL CONSTRUCTION SEQUENCING WITH PACTRUST AND SCHEDULE ALL SERVICE MINIMUM R4.2 INSULATION WITH FSK BARRIER. w INTERRUPTIONS OUTSIDE NORMAL BUSINESS HOURS TO MINIMIZE INCONVENIENCE TO CURRENT TENANTS. 09 53 00 SUSPENDED ACOUSTICAL CEILING _ ! - NOT TO SCALE LL 1. IN EXISTING SPACES REPLACE WATER STAINED OR DAMAGED TILES. d. HANGERS 12 GAUGE WIRE OR 18-GAUGE 1"WIDE STRAP. EXPOSED DUCT MUST HAVE ALL THREAD GENERAL HANGERS AND FULL DIAMETER STRAP UP TO 18"0. LARGER THAN 18"MUST HAVE SADDLE TYPE CLAMP. 1. REMOVE ALL EXISTING VCT,SHEET VINYL,ETC.IN AREAS WHERE NEW FLOOR COVERING IS SPECIFIED PRIOR 2. TUNE UP GRID SYSTEM TO WITHIN PLUS OR MINUS 0.5 INCHES OF LEVEL. e. BRANCH DUCTS SHALL BE PLUMB AND SQUARE(NO OCTOPUS). TEES SHALL BE MAXIMUM OF 45 4 TO INSTALLATION OF NEW FLOORING. 3. BENT OR DAMAGED T-BARS TO BE REPLACED. DEGREES. 2. ALL ROOF PENETRATIONS FOR ELECTRICAL,LOW VOLTAGE,GAS PIPING,ETC.SHALL BE SLEEVED THROUGH 4. REPAIR HOLES IN GRID FROM REMOVED WALLS. USE OF ARMSTRONG"BP ES-4"EXPANSION SLEEVE f. EACH BRANCH DUCT TO HAVE BALANCE DAMPER IN Y BRANCH. A LEAD ROOF JACK,CLAMPED WITH A STAINLESS STEEL CLAMP AND SEALED WITH VULKEM 921 ACCEPTABLE. g. ALL DISTRIBUTION DUCT WORK TO BE INSTALLED MIN.24"ABOVE FINISH CEILING. AREA OF WORK POLYURETHANE SEALANT. SILICONE SEALANT NOT PERMITTED. 09 65 19 RESILIENT FLOORING-VINYL COMPOSITION TILE _ IS 18.FLEX DUCT WILL BE NO LONGER THAN 6'FROM RIGID DUCT DOWN TO DIFFUSER. III NMI MIMI =ft 01 73 29 CUTTING AND PATCHING 19.DIFFUSERS: rMilaTh--"rn-- 1. FINISH FLOORING TO EXTEND UNDER CASEWORK. 1. PERFORM CUTTING AND PATCHING WITH SKILLED CRAFTSMEN EXPERIENCED WITH THE TYPE OF WORK 2. INSTALL TILES IN QUARTER TURN PATTERN. J BEING UNDERTAKEN. a. SUSPENDED CEILING SYSTEM(T-BAR)-PERFORATED FACE ADJUSTABLE CURVED BLADES-DESIGN - .2. PROTECT EXISTING CONSTRUCTION TO PREVENT DAMAGE. 09 91 23 PAINTING TITUS PCS SUPPLY AND TITUS PAR RETURN OR APPROVED EQUAL. 'INTERIOR: b. GYPSUM BOARD CEILING;SUPPLY-CURVED BLADE WI OBD DESIGN TITUS 250;RETURN-BAR TYPE- 113. PERFORM CUTTING USING METHODS LEAST LIKELY TO DAMAGE ELEMENTS TO BE RETAINED. DESIGN TITUS 350;EXHAUST-METAL OR ALUMINUM-1/2"x 1/2"EGG CRATE DESIGN TITUS 50F.4. PATCH,USING MATERIALS IDENTICAL TO EXISTING MATERIALS THAT VISUALLY MATCH EXISTING ADJACENT 1. WALLS: - T�TSURFACES TO THE FULLEST EXTENT POSSIBLE a. PRIME NEW DRYWALL WITH MILLER'S HIGH-BUILD"SUPER SEAL"PRIMER. c. ALL SUPPLY REGISTERS TO HAVE MANUAL VOLUME DAMPERS LOCATED IN DUCT AT OR NEAR CLOSESTWYE BRANCH. ii� 5. PATCH WITH DURABLE,INVISIBLE SEAMS THAT ELIMINATE EVIDENCE OF PATCHING AND REFINISHING. b. NEW AND EXISTING DRYWALL TO BE FINISHED TO ACHIEVE UNIFORM COVERAGE WITH MILLER'S 6200 OR d. CLEAN OR REPLACE ALL SUPPLY AND RETURN AIR GRILLS AND THEIR HOUSINGS AT PROJECT 6. AT CONCRETE SLAB REPAIRS(POUR BACKS),PROVIDE#3 x 12"LONG REBAR DOWELS AT 24"O.C. MIN.WITH 4480 WITH A TIGHT ROLLER STIPPLE FINISH. RESTROOM FINISHES TO BE MILLER'S S/G LATEX ENAMEL. COMPLETION. MIN.6"PENETRATION INTO EXISTING CONCRETE AND MIN,OF 6"EXPOSURE INTO POUR BACK.CENTER 2. DOORS AND FRAMES: 20.THERMOSTAT: ALL EXISTING MERCURY TYPE THERMOSTATS TO BE REPLACED. NEW THERMOSTATS TO BE •� M• O DOWEL IN SLAB DEPTH. i 101 a. NEW HOLLOW METAL-PRIME,SAND,AND FINISH WITH TWO COATS OF SEMI-GLOSS OIL. HONEYWELL COMMERCIAL GRADE VISIONPRO 8000 TOUCH SCREEN MODEL TB8220U1003 WHERE POSSIBLE. 7. REMOVE PATCHES THAT ARE VISUALLY UNSATISFACTORY IN THE ARCHITECTS OPINION AND REPLACE AT NO APPROVED SUBSTITUTE: TOTAL-LINE SIGNATURE COMMERCIAL THERMOSTAT MODEL NO.P374-2800 -7 DAY _____ b. EXISTING HOLLOW METAL-SAND,FILL IMPERFECTIONS WITH BONDO,SAND AND PRIME PATCHES WITH PROGRAMMABLE WITH LOCKOUT FUNCTION-AUTO CHANGEOVER ONLY. MOUNT AT ADA HEIGHT(MAY "I r • ADDITIONAL COST. ALKYD PRIMER,AND FINISH WITH SEMI-GLOSS OIL ENAMEL. REQUIRE CHANGING HEIGHT AT"REPLACEMENT'LOCATIONS). CONTRACTOR SHALL PROGRAM I7.'4 03 7.'403 00 00 CONCRETE c. WOOD-PRIME WITH ALKYD OIL UNDER-COATER,SAND,FILL ALL FASTENING HOLES WITH PAINTER'S THERMOSTATS AND BALANCE SYSTEM. -----� ------M-SC - MI - = ------ 1. EXTERIOR FLAT WORK: PUTTY,CAULK ALL CRACKS IN CASINGS AND BETWEEN JAMBS AND WALLS USING DAP LATEX CAULK, 21.THERMOSTAT LOCATIONS TO BE REVIEWED BY ARCHITECT PRIOR TO INSTALLATION. p AND FINISH WITH SATIN OIL ENAMEL. a. 4"THICK UN-REINFORCED CONCRETE SLAB WITH AIR-INTRAINMENT OVER 4"COMPACTED CRUSHED 22.EXHAUST FANS: ^ l W ROCK(3/4 MINUS). d. WOOD-STAIN,SEAL AS REQUIRED,AND VARNISH WITH SATIN VARNISH. `L/ 3. CEILINGS: a CEILING MOUNTED EXHAUST FANS SHALL HAVE A MINIMUM PERFORMANCE TO MEET THE CURRENT - b. CONTROL JOINTS 5'O.C.MAX,EXPANSION JOINTS 20'O.C.OR AS SHOWN ON PLANS. CODE REQUIREMENTS INCLUDING INTEGRAL BACKDRAFT DAMPER AND VENTING TO THE EXTERIOR. 2 BUILDING PLAN c. BROOM FINISH WITH TOOLED EDGE EACH SIDE. a. EXISTING GYP BOARD/PLASTER-SAND,SPACKLE ALL IMPERFECTIONS,SPOT PRIME AND FINISH TO COOK GEMINI SERIES 100 OR EQUAL;80 CFM WITH A SONE RATING OF 1.6 OR LESS,100 CFM WITH A CD 08 10 00 DOORS AND WINDOWS ACHIEVE UNIFORM COVERAGE WITH MILLER'S 6200 OR 4480. SONE RATING OF.9 OR LESS,200 CFM WITH A SONE RATING OF 1.6 OR LESS. A-1 SCALE 1"= 50' lT//�) U 4 b. NEW GYP BOARD/PLASTER -PRIME WITH SUPER SEAL AND FINISH TO ACHIEVE UNIFORM COVERAGE b. SPECIALTY ROOMS REQUIRING EXHAUST SHALL MEET THE ABOVE MINIMUM REQUIREMENTS- v D W P.1 et 1. RE-USE EXISTING DOORS AND FRAMES WHERE POSSIBLE WITH MILLER'S 6200 OR 4480. INDIVIDUAL ROOMS WITH AN EXHAUST REQUIREMENT GREATER THAN 250 CFM,SHALL HAVE A H N ROOFTOP MOUNTED FAN. MN 2. APPROVED DOOR,FRAME,AND HARDWARE SUPPLIERS INCLUDE: 4. GENERAL NOTES: W g Q to; 23.HVAC TESTING. V0/ a. BAXTER AND FLAMING. (503)225-0486 a. KEEP ALL HARDWARE,HINGES,AND DOOR KNOBS CLEAN OF ALL PAINT SPLATTERS,DRIPS,OR ROLLER - O - C4 b. D&D DOOR (503)205-5533 SPRAY. a. CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES,COMPONENTS, p., a O b. ALL SURFACES TO BE SANDED BETWEEN COATS,PRIOR TO INSTALLATION OF NEXT COAT. EQUIPMENT AND SYSTEMS ARE CALIBRATED,ADJUSTED AND OPERATE IN ACCORDANCE WITH '�J c. BENSON INDUSTRIES (503)907-2200 APPROVED PLANS AND SPECIFICATIONS. Imo. ^, 0 T/J d. GRANT SUPPLY c. DURING PROGRESS OF WORK,KEEP JOB SITE CLEAN OF ALL PAINT MATERIALS,RUBBISH,CANS,AND ` V (360)887-0647 b. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE IN Q U RAGS AT THE END OF EACH DAY. ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. 4.1 3. DOOR AND RELITE FRAMES SHALL BE WESTERN INTEGRATED MATERIALS MIM), OR APPROVED. SUBMITTAL U o REQUIRED PRIOR TO ORDERING MATERIAL.NEW FRAMES TO BE FACTORY FINISH CUSTOM COLOR. d. UPON COMPLETION OF WORK,CLEAN ANY PAINT SPLATTER BY USING PROPER METHODS OF WASHING a A COMPLETE COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND W '[[z��.,, FRAMES AND SCRAPING,USING CARE NOT TO SCRATCH OR DAMAGE FINISHED SURFACES. FILED WITH PACTRUST. 0 U I--1 en H 4. 14-GA.IOR DOORS AND GALV.SHEET TTEEL DOORS,SDI--1LLOW 100 GRADEAL. FRAMES OF ONE-PIECE II,SEAMLESS EDGES,16 GA.GALDED V.SHEET STEEL.ION e. PROTECT WORK OF OTHER TRADES. 24.PROJECT CLOSE OUT DOCUMENTS REQUIRED: c d en 0 FABRICATE DOORS AND FRAMES WITH HARDWARE REINFORCING WELDED IN PLACE. f. PROVIDE"WET PAINT'SIGNS AS REQUIRED TO PROTECT NEWLY PAINTED FINISHES. a. AutoCAD FILE SHOWING AS-BUILT INFORMATION. �'i•( P-i •-1 0.1 5. FIELD VERIFY EXISTING DOOR,FRAME AND HARDWARE FINISH PRIOR TO ORDERING. ALL NEW DOORS, 10 00 00 SPECIALTIES b. ELECTRONIC PDF FILE OF THE AutoCAD FILE ABOVE. FRAMES AND HARDWARE TO MATCH EXISTING BUILDING STANDARDS. 10 28 13 BREAK COUNTER c. HARD COPY OF AutoCAD FILE ABOVE. REVISION 6. ALL INTERIOR DOORS SHALL BE SOLID CORE WOOD UNLESS NOTED OTHERWISE. 1. PAPER TOWEL DISPENSERS,SURFACE MOUNTEDKITCHENIBREAK ROOM)BOBRICK B-262 7. DOOR HARDWARE SHALL BE SCHLAGE AL SATURN OR D RHODES SERIES U.N.O. ( d. OPERATIONS MANUALS FOR ALL EQUIPMENT,INCLUDING T-STATS. 1044 16 FIRE EXTINGUISHERS e. COLORED ZONE MAP WITH THERMOSTAT LOCATIONS INDICATED. 8. ALL DOOR HARDWARE SHALL BE INSTALLED WITH A 5'BACKSET. 1. FIRE EXTINGUISHER 2A10 BC ALL MOUNTED OR IN SEMI RECESSED CABINET AS INDICATED ON PLAN) 1. 9. DOOR FINISH SUBMITTAL:CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR DOOR FRAMES,DOOR 26 00 00 ELECTRICAL : DESIGN/BUILD HARDWARE AND DOORS AS WELL AS A CONTROL SAMPLE OF THE FINISHED DOOR SKIN W/STAIN AND FINISH 2. FIRE EXTINGUISHER CABINET: JL INDUSTRIES ACADEMY SERIES MODEL#C1027V10. GENERAL 2. APPLIED(IF NEW DOORS ARE BEING PROVIDED). BEFORE FINISHING OF DOORS IS COMMENCED ARCHITECT 12 00 00 FURNISHINGS 1. ALL ELECTRICAL FEEDS TO OUTLETS,SWITCHES,ETC.MUST BE VERTICAL DROPS FROM ABOVE EXCEPT FOR 3 SHALL APPROVE CONTROL SAMPLE. FINISHED PRODUCT IS SUBJECT TO REJECTION BY ARCHITECT IF THIS HORIZONTAL RUNS UNDER WINDOWS AND RECEPTACLES ON THE SAME STUD. PROCESS IS NOT FULLY ADHERED TO AND FIELD PRODUCT DOES NOT MATCH THE APPROVED CONTROL 1. CLEAN/REFURBISH EXISTING BUILDING STANDARD BLINDS AT ALL EXTERIOR GLASS. SAMPLE. 2. INSTALL BUILDING STANDARD ADDRESS AND/OR SUITE NUMBER LABELS TO ALL EXTERIOR DOORS. 2. ALL ELECTRICAL FEEDS TO OUTLETS AND DATA BELOW WINDOW SILLS TO BE ROUTED THROUGH BUILDING 4 10.ALL INTERIOR GLAZING SHALL BE TEMPERED. SHELL WALLS. DO NOT FEED FROM PERPENDICULAR INTERIOR PARTITIONS. 21 00 00 FIRE SUPPRESSION : DESIGN/BUILD 3. PROVIDE LABELS AT EACH ELECTRICAL RECEPTACLE IDENTIFYING CORRESPONDING PANEL AND BREAKER. 08 4313 ALUMINUM STOREFRONT DOORS AND WINDOWS 5. 1. ADJUST EXISTING SPRINKLERS THROUGHOUT SPACE AS REQUIRED BY CODE. SPRINKLER HEADS SHALL BE 3. PROVIDE TYPEWRITTEN UPDATED SCHEDULE AT PANEL TO IDENTIFY CIRCUIT BREAKERS. 1. DOOR/WINDOW FRAMES:2"x 4 1/2"OS GLAZED. CENTERED IN 2 X 2 CEILING TILE.LAYOUT OF SPRINKLERS BY CONTRACTOR, SPRINKLER LAYOUT IN ALL HARD 6. 2. DOORS:1 3/4"X 3 1/2"TOP RAIL AND STILES AND 1 3/4"X 10"BOTTOM RAIL,SQUARE GLAZING STOPS. CEILING AREAS(GYPSUM BOARD/PLASTER)TO BE REVIEWED AND APPROVED BY ARCHITECT PRIOR TO 4. VERIFY ELECTRICAL METER AND TAG METER WITH THE TENANT'S ADDRESS OR SUITE NUMBER. METER CITY OF TIGARD INSTALLATION. IDENTIFICATION NUMBER AND TENANT ADDRESS INFORMATION SHALL BE GIVEN TO PACTRUST PRIOR TO REVIEWED FOR CODE COMPLIANCE- 7. 3. DOOR HARDWARE:DEAD BOLT LOCKS AT NEW EXTERIOR DOORS TO BE INSTALLED WITH A SCHLAGE TENANTS MOVE-IN. MORTISE DOUBLE CYLINDER 20-013C "C'KEYWAY;SOLID BRASS;WITH ADAMS-RITE CAM AND COMPRESSION 22 00 00 PLUMBING : DESIGN/BUILD 5. ELECTRICAL CONTRACTOR TO PROVIDE EMERGENCY LIGHTING IN EXIT PATH SHOWN ON PLAN EQUAL TOI t.--r- RING 1 1/8"LENGTH WITH HARDENED CYLINDER GUARD RING KEEDEX K-24. GEAR HINGES. FINISH TO MATCH GENERAL REQUIREMENTS Approved: G lO C� U I a I 1 l..( 8. BUILDING STANDARD. 1-FOOT CANDLE. L 4. APPROVED DOOR,FRAME,AND HARDWARE MANUFACTURERS INCLUDE: • 1. CONTRACTOR TO SUBMIT LAYOUT ON ELEVATIONS AND PLANS PROVIDED FOR ALL SHUT OFF VALVES,CLEAN 6. EXIT LIGHTS:RUUD LIGHTING"PLASTIC LED EXIT SIGN"MODEL EXPBURWH RED LETTERS,WHITE HOUSING, n OUTS,ACCESS DOORS,AND FLOOR DRAINS TO THE ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION. WITH BATTERY BACKUP. Permit# -7 LLP0910 49-(71' /00 Q O a. CASCADE ALUMINUM 2. PLUMBING CONTRACTOR TO PROVIDE AND INSTALL(1)MASTER SHUT OFF VALVE FOR EACH SET OF 7. WHERE NEEDED,CONTRACTOR TO FURNISH AND INSTALL NEW DRY TYPE TRANSFORMERS TO PROVIDEDRAWN BY: b. KAWNEER RESTROOMS. LOCATE VALVE BEHIND HANDICAP WATER CLOSET IN MEN'S TOILET ROOM. 208V/120V POWER FROM THE 480V/277V SYSTEM. SIZE TO BE BIDDER DESIGN. Address: 5 VS jr `e OCA- R.M.T. c. US ALUMINUM 3. ALL DOMESTIC WATER PIPING TO BE TYPE L COPPER-NO EXCEPTIONS. ALL EXPOSED PIPING TO BE a. TRANSFORMERS TO BE ENERGY STAR LABELED. Suite •• ' _c a' - r 5. FINISH: <CLASS I DARK BRONZE ANODIZED FINISH(OR BLACK-MATCH EXISTING),0.7 MILS THICK><CLASS I INSULATED. b. CASE TO BE TOTALLY ENCLOSED WITH LOUVERS TO PREVENT FOREIGN OBJECTS INTO THE INTERIOR. ,qO -� f r, DATE: 5/25/16 CLEAR ANODIZED FINISH,0.7 MILS THICK> 4. WATER HEATER(ELECTRIC)30 GAL AND LARGER 277V LESS THAN 30 GAL 120V. PROVIDE HUB DRAIN AT By: At,l�� Date: "` V� 777 c LOCATION FOR BLOW OFF. c. ENCLOSED AND VENTILATED,AIR COOLED TYPE,CLASS H INSULATION,DESIGNED FOR 115 DEGREES C PERMIT SET 09 00 00 FINISHES 5. POINT OF DEMAND WATER HEATER-BOSCH POWER STREAM PRO-MODEL RP2P 277V/30A. ADJUST WATER OPTEMPERATURE RISE ABOVE 40 DEGREES C AMBIENT TEMPERATURE AT FULL LOAD CONTINUOUS ' • GENERAL FLOW SETTING TO PROVIDE A HEATING RANGE OF 105 TO 120 DEGREES. CONTACT MESHER SUPPLY FOR SOUNDUNLEVEL EQUIP BEEH 2-I NEMA2 PERCENT WITHNFC TAPS AND FOUR DAMPERS2-1/2 PERCENT BNFCHTAPS. MAXIMUM AVAILABILITY,(503)236-4148. EM SHALLS STANDARD ISOLATION BETWEEN THE CORE AND COIL 1. CLEAN,SEAL AND WAX ALL RESILIENT FLOORS PER MANUFACTURERS SPECIFICATIONS. ASSEMBLY AND CASE. o����� COPY 2. SUBMIT SAMPLES OR DRAW DOWNS FOR THE FOLLOWING: 6. FLOOR DRAINS SHALL BE INSTALLED IN TOILET ROOMS CONTAINING TWO(2)OR MORE WATER CLOSETS OR 2 9, FOR FLOOR POWER AND DATA ACCESS IN BUILDINGS WITH ACCESS BELOW FLOOR,USE WIREMOLD RC7 • a. FLOOR COVERINGS,BASE AND TRANSITION STRIPS OR MORE WATER CLOSETS AND URINALS IN COMBINATION. THE FLOOR SHALL SLOPE TOWARD THE FLOOR FLUSH POKE-THRU SERIES OR EQUAL. FOR SLAB ON GRADE INSTALLATIONS USE RACO#5511,2 AT EACH DRAIN. LOCATION TO SEPARATE POWER AND DATA WITH 1'CONDUIT FOR POWER AND 2'CONDUIT FOR DATA. b. PLASTIC LAMINATES 7. FLOOR DRAINS TO BE INSTALLED WITH PRIMER VALVE WITH ISOLATION VALVE. NO ATMOSPHERIC PRIMERS. 10.LOW VOLTAGE SYSTEMS(TELECOMMUNICATION AND DATA)BY FUTURE TENANT. c. ALL NATURAL WOOD(INCLUDING DOORS AND CASEWORK) DRAINS TO BE PRIMED FROM TOILET FIXTURES UNLESS OTHERWISE APPROVED BY PACTRUST. PROVIDE A . d. PAINT MIN. 12"x 12"ACCESS DOOR. 11.LIGHTING ENERGY MANAGEMENT IS REQUIRED IN ALL BUILDINGS. A - i 12.OCCUPANCY CONTROL DEVICES SHALL BE LEVITON OR WATT STOP. e. TILE,MARBLE,GRANITE,STONE,GROUT AND SCHLUTER TRIMS 13.TEST ALL LIGHTING CONTROL SYSTEMS TO ENSURE THAT CONTROL DEVICES,COMPONENTS,EQUIPMENT f. TOILET PARTITIONS AND SYSTEMS ARE CALIBRATED,ADJUSTED AND OPERATE IN ACCORDANCE WITH APPROVED PLANS AND BUILDING DEPARTMENT USE \ \ #3082 %/ \ It 6 „ 1 n C1 9 \1 O \' MARTIN W. HANSON vei 5 1 \. `��' \'N._� \.. ��' �_.- cp CLA,KAMAS, OREGON teA / REMOVE NC SYMBOLS l- OF STRIPE PAWING STALL OR NO PA / PROD # 16280 PAWING - ADD HC PARKING \ ADD HC PARKING ��`i �s � _\ �I`, .;\ SYMBOL SYMBOL SNI_, ii. ,t{ 'VI ii EISc lc ,I W Emi 0 NEW HC PARKING SIGN 4 °' 4 NEW NC PARKING SIGN O DOOR SCHEDULE 0 8 • ° DOOR DATA FRAME DATA HARDWARE Fire Rating Remarks Mark Door Size TI-k. Core Veneer Finish Hand Type Frame Depth Hardware Manufacturer Finish Function 190 3'-0'x 8'-0' 11/2' -- ALIM/GLASS -- Left • -- 5' CLOSER/LEVER LOCK ADAMS RITE 613 OIL RIBBED BRONZE 45b0 -- ri 908 3'-0'x 9'-0' I 3/4' SC OAK WATCO Right • BLDG.STD 41/8' LEVER/LOCK/CLOSER SCHLAGE 613 OIL RIBBED BRONZE AL53PD NEW INTERIOR DOOR a('`1 NEW CONC.WALK • CV r-- ___ i O� OV1 en N A i A 1 i tE ==y-.,_ LN N a• SPRINKLE' I I__ M M rn OO 19101 -414 Ip og �� I I90 —KA -�'1 V'1 O `Z X N �� .~P. aur Ir — — — rr1 1 �� _ _ __ _ — — _ i T ABBREVIATIONS 4 FINISH MATERIALS A I ALL FINISHES MUST BE SUBMITTED TO PACTRUST PRIOR TO INSTALLATION. BRK BRICK PAVERS CP# CUT PILE CARPET 1 CIRC. ;itkli FER I CR CHAIR RAIL ocaTe casE aRc PLunBINGCARPET TILE: 909 A D DISHW45HER ro ADJACENT �� �' LP-1 PATCRAFT CONSTRUKT COLLECTION , LIQUID PATTERN E EXISTING TENANT SPACE Iy_ I ETR EXTEND TO ROOF Ill r_� __ �_ ROCK SCISSORS PAPER 00765 I I I FWC FABRIC WALL COVERING n _414 or j j 1 OFFICE I VINYL COMPOSITION TILE LL OPEN OFFICE -Clj I I 193 GT HOLLOW cy �_ VCT ARMSTRONG STANDARD EXCELON 51868 SMOKEY BROWN, 12"x 12"x 1/8” HM METAL 0 04 a 190 y I I PGWB PAINTED GYPSUM WALL BOARD 7 I: BASE PL4 PLASTIC LAMINATE a Lf ' Lf" D _ RF FLEXCO 4"FLAT RUBBER BASE,038 OUTER BANKS AT ALL CARPET AREAS. PLW PLASTIC LAMINATE WAINSCOT I RC FLEXCO 4"COVE RUBBER BASE, 038 OUTER BANKS AT ALL HARD SURFACES. POT PORCELAIN TILE 1 CIRC. 0 POTW PORCELAIN TILE WAINSCOT e F 906 IN VACANT SPACE PAINT: PT4 PAINT fn k'ia PROTECT ALL FINISNES PT-1 MILLER 4480 PREMIUM SATIN LATEX,0195W MOSSY SHADE (FIELD) RC RUBBER BASE COVED N 1 xx�y D FROM CONSTRUCTION DAMAGE. 3 1 i � "` DEBRIS OR DanAGI=. PT-1 MILLER 4480 PREMIUM SATIN LATEX,0198M YOUNG COLT (ACCENT) RF RUBBER BASE FLAT ItJ SAT SUSPENDED ACOUSTICAL TILE 4 fir ry� BUILDING ELECTRICAL CONFERENCE / LAMINATE: SC SEALED CONCRETE A in �'J I to of 191 STORAGE PL-t WILSONART D327 60 PEPPERDUST,AT ALL FACES SV SHEET VINYL 19e PL-2 WILSONART 4674-60 EVENING TIGRIS, COUNTER, B.S.AND SELF-EDGE. VCT VINYL COMPOSITION TILE rd H ER SHOWER WBC WALL BOARD CEILING CAB PULLS 613 OIL RUBBED BRONZE sos WCG WALL CORNER GUARD x XDOORS, HARDWARE AND FRAMES VVD WOODn L 1 HARDWARE 613 OIL RUBBED BRONZE WOC WALK OFF CARPET i1� Cl FRAMES PAINTED ANODIZED ALUMINUM WW WINDOW WALL J JAN. T CONTRACTOR TO PROVIDE BUILDING STANDARD BLINDS AT ALL EXTERIOR GLASS. soy j o �C ='fir - - - - C ) ol _ -I ,,. CIRC. ' T C -oH 9013 I G 10, H I 0 MEN It 0 WOMEN sot �J 904 OD 0 I I 1 gt co I C 1 L {I F" N 1 I v I ° ga ITh LOBBY V 19311 �� CONSTRUCTION LEGEND a U ¢ o QPI ^^ � Mx I I EXISTING TO REMAIN `�T = _ _ = EXISTING TO BE REMOVED REVISION (C) • ( - I r,,,,,,,,,,,,, Ali NEW STANDARD WALL R I ® ElkNEW STANDARD WALL WITH INS. - 1 N ZS NEW SOUND WALL WITH INS. 2. VESTIBULE - - o 3. '�. c , 900 r c I / —.— — — — — — - — 0 DUPLEX RECEPTACLE a ELECTRICAL PANEL 4 (;i FOURPLEX RECEPTACLE 0 POWER J-BOX ° 0 DEDICATED OUTLET6 ® FLUSH MOUNT FLOOR MONUMENT WI POWER AND DATA 6. 0 EXISTING ELECTRICAL TO REMAIN © FIRE EXTINGUISHER IN RECESSED CAB. 7. PARTITION AND POWER PLANN flil FLOOR MONUMENT WI SERVICES SHOWN ® FIRE EXTINGUISHER-SURFACE MOUNTEDCD 8 \A'2 SCALE 1/8" = l'-0" (11)OUTLET OT THERMOSTAT 4 TELIDATA MUD RING WITH PULL STRING DRAWN BY: R.M.T. >< 2 X 4 FLUOR.FIXTURE X SUPPLY DIFFUSER PARABOLIC LENSE Al RETURN DUCT DATE: 5/25/16 'lIIIItm• 2 X 4 FLUOR.FIXTURE PERMIT SET 1111 PARABOLIC LENSE/STEADY BURN BALLIST ® EXHAUST FAN It 2 x 4 FLUOR.FIXTURE TILLS SPRINKLER HEAD 0 FOUR LAMP T5 FIXTURE B EXIT SIGN(LED RED) 0 RECESSED COMPACT FLUORESCENT LIGHT(TYP.) 0cm HORN/STROBE FIRE ALARM(WALL MOUND 4 RECESSED COMPACT FLUOR.WALL WASH FIXTURES. 10 M HORN/STROBE FIRE ALARM(CEILING MOUNT) a a a TRACK LIGHTING A . 2 ® SMOKE DETECTOR #3082 \ \ \ �� S MARTIN i NANSONj 5 7 ! � 8K___Ur____ l o \ � CLA KAMAS, OREGON,1 \ , 240'-0" PROD # 16280 I II 301_011 1 30'-011 251_011 I _ 251_011 25 -0 _ _ v I �\ 1 NEW EXIT LIGHT I I - `/ / \ IN SIT (/ A \ _ I-- I I - 1 _ T I H -T T _l__ 1__L , z e A: 1 _ N / I � ( ) — 1 — � bH 0 N. X I ao M 1 ► I • /17 ! _ 1 x „<__, ICel Cc)choo co `I •�� s, _ m a a w II Q a d L 'tom �' rillihthw 1K /2I -1•111r - 1 4 j .C0 - F' >< II III 1 I _ � a II � 1. i ..�s. 1- a 11 o _1 •■• mo- _ _ - - L]— - 40 i LHEID T- . _ iicti Ii Gar' Go I G i I CO , I I Ir il 1 CO 1 r i (--a9C> � t 1 - - - - - -- —r-- —I Waw ' I M N Il 1 W , iii I 00x N ! I - - 1 N o � I O _ r I I ,. U, I , ._ :, I V v 3 ■ w E ! ' 1 - - - - - - CONSTRUCTION LEGEND 0 0 M M eve-1 0 i I EXISTING TO REMAIN I = n - = EXISTING TO BE REMOVED REVISION ®REFLECTED CEILING PLAN SCALE 1/8"= 1'-O" [vii ii i ii,zzA w NEW STANDARD WALL 1. E � INDICATES COMMON PATH OF TRAVEL REOUIREING EMERGENCY wu NEW STANDARD WALL WITH INS. LIGHTING EQUAL TO 1-FOOT CANDLE. ...mom= 9 NEW SOUND WALL WITH INS. 2 3. 0 DUPLEX RECEPTACLE a ELECTRICAL PANEL 4 FOURPLEX RECEPTACLE ® POWER J-BOX 5. ° 0 DEDICATED OUTLET ® FLUSH MOUNT FLOOR MONUMENT WI POWER AND DATA 6 Q♦ EXISTING ELECTRICAL TO REMAIN Cp FIRE EXTINGUISHER IN RECESSED CAB. 7 FLOOR MONUMENT W SERVICES SHOWN ® FIRE EXTINGUISHER-SURFACE MOUNTED 8. SPECIAL OUTLET ® THERMOSTAT 4 TELIDATA MUD RING WITH PULL STRING DRAWN BY: R.M.T. \/ 2 X 4 FLUOR.FIXTURE SUPPLY DIFFUSER /\ PARABOLIC LENSE `'' RETURN DUCT DATE: 5/25/16 PERMIT SET ►^IIIIP^- 2 X 4 FLUOR.FIXTURE 1111 PARABOLIC LENSE/STEADY BURN BALLIST EXHAUST FAN 2 x 4 FLUOR.FIXTURE niE SPRINKLER HEAD O FOUR LAMP T5 FIXTURE e EXIT SIGN(LED RED) RECESSED COMPACT FLUORESCENT LIGHT(TYP.) v� HORN/STROBE FIRE ALARM(WALL MOUNT) AtiV RECESSED COMPACT FLUOR.WALL WASH FIXTURES. (G ns Ip HORN/STROBE FIRE ALARM(CEILING MOUNT) Al.. 3 a a a TRACK LIGHTING 0 SMOKE DETECTOR RACO HEAD (ce '"L:41; 20 GA 3 5/8'METAL STUD BRACING #W. H o MARTIN W. ANSON TO ROOF STRUCTURE AT 10'-0'OC WHERE REQUIRED o 1 u / 6' �CLA KAMAS, OREGON ROOF DECK 2'-m' ' LITE KIT WHERE SPECIFIED OR BEAM t .— ' �` EXISTING SUSPENDED GEILNG et �/ � RACO STYLE RECESSEDerr / / `r v OF O� _ RACO STYLE CON EG PT WALLS"1-48TRDT HEADER RECESSED REVEAL .n z ' HEADER CONCEPT SUSPENDED CLG ASSEMBLY z o / PROD # 16280 WALLS II-dBTRDT ° — _ O a � '---A— O 0 0- / Eli ADDI IONAL SWITCH - r�` E 3-5/8'MTL-STUDS • 24'OG. al w w LL \ GANG LOCATION Z �/ 5/8'GYP-BRD-BOTH SIDES o Til in 0I CENTER LINE OF STUD u W II 20 GA 3 5/8' METAL STUD BRACING N TO ROOF STRUCTURE AT I0-0' Qcz E OGW/ (2) "B SHEET METAL -4- \ do r l SCREWS AT EACH END. BRACING cd ELECTRICAL f cD F w U 1°1 TO BE PROVIDED WHERE DISTANCE " \ COR UTLET 3 0 o 4' RUBBER BASE-iYP. BETWEEN PERPENDICULAR INTERSECTING \ o = 0 f9- C...) ATTACH BOTTOM TRACK TO FLOOR WITH —� o Jr0POWDER DRIVEN ANCHORS AT 12 OG. rg IFINISH FLOOR 1 UNDERCUT TOOLA \ ZO e O0REQUIRED TH CLEAR v .n m O OFLOOR FINISH dr ' CA 2 41/8' 1 I r-i---A-4 TYPICAL WALL SECTION A-4 WALL BRACING DETAIL A 4 MOUNTING oHEIGHTS z N SCALE 1" l'-0" SCALE 3" l'-0" C SCALE 1/2" O o, pa o kr)vi 4 cC c5,'r2 20 GA 3 5/8'METAL STUD BRACING O O TO ROOF STRUCTURE AT 10'-0' OC / On py 00 41/4 WHERE REQUIRED ,M O x �, .''."�'��,� ,'�' R-II BAIT INSULATION 4' CENTERED OVER WALL ii / TYPICAL STUD ea—'. EXISTING SUSPENDED CEILING mmi �1 RACO STYLE RECESSED �� REVEAL HEADER sells CONCEPT WALLS.1-481RDT �� 0010 TYPICAL TRACK 3-1/2'BATT INSUL. INSTALL STUDS WITH SAME W 3-5/8'MIL.STUDS a 24' OG. DIMENSION (10' MIN.)FOR o W 011-.1111 BRIDGING ALIGNMENT N Q Fir 5/8' GYP.BRD.BOTH SIDES CENTER LINE OF STUD $1°' p O U ad al ii 0°. POWDER DRIvEN &.; ANCHORS AT 12' O.G. f ''wok 3-IR' BATT INSUL. IN SOUND ATTENUATION WALLS rn f1 1 �I m-16 SCREW C7 3 4' RUBBER BASE-TYP. " I ATTACH BOTTOM TRACK TO FLOOR WITH A POWDER DRIVEN ANCHORS AT 11' OG. PER STUD FLANGEIT �� FINISH FLOOR !►i _ 4 1/8' (2 WALL SECTION W/ SOUND INSUL. 6 WALL BASE DETAIL a A-4 SCALE 1"= 1'-O" \A-4 SCALE 3" = 1'-0" L 4 EXISTING WINDOW WALL / EXISTING GLAZING I / CN /// 112' SILICON BUTT GLAZE / 1 PLATE GLASS ALUMINUM GLAZING CHANNEL FASTENED TO 0 1 RACO WITH SCREWS. FAINT TO MATCH METAL W Iltn - ,-- , C:11 tl RACO STYLE RECESSED REVEAL TRACK, CONCEPT WALLS *1-481RDT MM EW, N rn 1-1 g,11 EXISTING WINDOW SILL /'�� ��j ap: Cin WALL STUD FLUSH WITH WINDOW SILL V R+ SMOOTH FIN. GYP BD. OVER METAL STUDS gU O 3 W - tri , CWINDOW CLOSURE AT WINDOW a u In o SCALE 3" = l'-0" REVISION 1. 2. 3. 4. 5. 6. 7. 8. DRAWN BY: R.M.T. DATE: 5/25/16 PERMIT SET