Plans (6) BU P2017 - 00050 K r \ II awas a er & Tolleson,1)04 RECEIVED P o FEB 2 8 2017 z CI'T'YOETIGAR :: v "o BUILDINGDIVT810I W Z O Ear v ac TIGARD, OR Ln i ° n. O ow tn 4 Tenant Improvement W ° v ,_ L N vri Q„ O ce 3 M O QJ c.s PROJECT TEAM PROJECT DATA/ CODE SUMMARY DRAWI\G I\DEX SCOPE DESCRIPTIO\ r1 BUILDING CODE SUMMARYI I COVER SHEET 2014 EDITION STATE OF OREGON STRUCTURAL SPECIALTY CODE (OSSC) THESE TENANT IMPROVEMENT PROPERTY OWNER Maher & Tolleson, LLC 2014 EDITION STATE OF OREGON MECHANICAL SPECIALTY CODE (GMSC) A4. 1 DEMO/FLOOR PLAN - 1ST FLOOR CONSTRUCTION DOCUMENTS INCLUDE 7190 SW Fir Loop 2014 EDITION STATE OF OREGON PLUMBING SPECIALTY CODE (OSPC) A4.2 DEMO/FLOOR PLAN - 2ND FLOOR THE ALERATION OF AN EXIST. 6,850 sq/ft Tigard OR 97223 2014 EDITION STATE OF OREGON ELECTRICAL SPECIALTY CODE (OSEC) A8. 1 RCP/LIFE SAFETY PLAN BUILDING. 2014 EDITION STATE OF OREGON FIRE SPECIALTY CODE (OSPC) CONSTRUCTION TYPE : VB TENANT IMPROVEMENT DOES NOT REQUIRE TENANT Maher & Tolleson, LLC 7190 SW Fir Loop TWO STORY BUILDING FULLY SPRINKLED/FIRE ALARM STRUCTURAL MODIFICATIONS. Tigard OR 97223 BLDG. AREA: =T.I. AREA: = 6,850 S.F.575 S.F. (USABLE) GROUND FLOOR, 3,230 - SECOND FLOOR) DEFERRED SUBMITTALS OCCUPANCY TYPE: B GENERAL OFFICE HVAC DESIGNER NW Precision Design ELECTRICAL U 22605 SW Pinehurst Ct. EXITING: (2) EXISTS PROVIDED FROM SECOND FLOOR AND (2) EXISTS PLUMBING Sherwood, OR 97140 PROVIDED FROM THE MAIN FLOOR (503) 680-6444 silen Contact: Darin Bouska rn OCCUPANCY: GENERAL OFFICE - GROUND FLOOR: 3,620 S.F. = 36 (GROSS) lo SECOND FLOOR: 3,230 S.F. = 32 (GROSS) O , 68 "oe b0 GENERAL BnK Construction, Inc. FIXTURE REQUIREMENT: OFFICE SITE MAP H o CONTRACTOR 45 82nd Drive, Suite 53By o � Gladstone, OR 97027 EXISTING 'COMMON AREA TOILET ROOMS, ARE SUFFICIANT FOR � ! (503) 557-0866 FAX - (503) 557-1085 THIS OCCUPANCY. (2) FIXTURES PER SEX (1) ADDITIONAL UNISEX TOILET ROOM w �-I Contact: Jared Shandy cn CCB#: 107555 4i F\ , ct R r,,,, ,,, SCOPE OF .WORK CITY OF TIGAL.D VICINITY MAP l r 1. J J REVIEWED FOR CODE CQMELIANCB CITY JURISDICTION City of Tigard Approved: i �� c �sc 13125 SW Hall Blvd. — OTCs I ! c1 Imo) 1-1- Tigard, � Tigard, OR 97223 �' 4 ' / Petmit#s . SCPPO6 7 50 (503) 718-2439 Pfk L �� • r AddresE t7l? O h RI ____________ ai > r = Suite# ' %di:cY e ! Br [.--2,1_, Date 17 ' • • ' Revisions: \ t_, OFFICE COPY 2 i ( .1, , , o \ R �-� — Hampton Ridge ®Touchstone Preschool /(� 1 . . Apartments 1 ' L D L._ "r biarn$S? �.. _ B f . ' - i N, i F . 4 4 1 . .' 1• , 1 ' + ? S't`i Fir St A l t «. Project Number: 03a Services d 4 O aw as Na .....r ; `%\ ri �IJM /i 1 0 a. Oo Igl ® X11 p lel is=JIF 4-11 © - O rn .y eL ;v 0 I, - K--- os Q N Om ® -�� _I u� LA u U O 13 v = k o- 1 I f I I 11SCHEDULE 11 �./ O O I _ • DOORS FRAMES/REL ITES DEMO NOTES SIZE DESCRIPTION DES(. N W -Id ZN 1 . DEMO PLAN — FIRST FLOOR O W w QW WSW W 9 LL REMOVE EXISTING, NON-STRUCTURAL WALL z �� G il PARTITION p p �'gel j p LL�p c p H 0 �op REMARKS SCALE: I/811 = 11-0" - b 5z ':-TW Ts a 9 C69 w i cm It a Z z © REMOVE DOOR/FRAME ROOM NM W I-I T S P MAT. FIN. TYPE E L MAT. FIN. O REMOVE CASEWORK 100 PRIVACY SET 101 30" • PASSAGE SET 102 • PRIVACY SET QREMOVE LIGHT FIXTURE 103 PASSAGE SET (STOCKPILE FOR POSSIBLE RE-USE) © REMOVE 4 'CAP' EXIST. FIXTURE (IN-WALL OR BELOW FLOOR) - (3) WATER CLOSET NOTE: DOOR HARDWARE TO BE GRADE I, DORMA CL800-LG OR APPROVED SUBSTITUTE - (I) URINAL ALL DOOR HARDWARE TO BE LEVER AND A.D.A. APPROVED, 626 FINISH - (4) LAV. SINKS VERIFY ALL FINISHES W/TENANT - STRUCTURAL ENGINEER TO VERIFY ANY STRUCTURAL WALLS OR COLUMNS PRIOR TO DEMOLITION. - SAFE-OFF ALL ELECTRICAL (41G1-1 VOLT 4 LOW VOLT) U PRIOR TO DEMOLITION ATTACH W/(2) "8 to WOOD SCREWS, TON EXIST WOOD STRU7 rn NOTE: ANY WALL OVER 8'-0' LONG u.O O rjj SHALL BE BRACED AS SHOWN. ,I LCO- 3ai8' 25 GA, MTL. STUD BRACES .1 po " 11 L I1 11 1 ( C*C*��yy.``JJ�I��y}} 1 11 11 II 11 11 TO STRUCT. ® 8'-0' O/C - STAGGERED n1 F.I .-- [-LI n--I - - �pI w 6' METAL STUD, 20 GA, 16' O.G. CD o _ OFFICE OFFI5• OFFICE44 I j ;.-1' 44 Pal la.) R 4 p rn _ r � Ci Ri ��1in 5/8' TYPE 'X' SHEETROCK EACH SIDE 3%' MTL. STUDS 20-GAUGE m 24' o%. fiW I — 'D _ BOTTOM TRACK ATT. TO 00 sA " I II FLOOR � 24' O/G W/ O I' __-i I s POWDER DRIVEN ANCHORS _ © itrir 2 = ..i E OEC �� 1 1 _ 101 Ir \ —\. TOILETOD 4° EXISTING FLOOR • = I O 1;' e ' ,O® 0102 � _ METAL STUD WALL DETAIL (AT TOILET) ci 1 N.T.S Revisions: N\ ----) 1--F L J ) i- _ ® -.....-A----1- ' I -• - u - - L - 40° EPDXT 4.6 FIRST COAT TO CONSIST OR APPLICATION pFOL lNTTNG' SRIANER/SELR �MLg / , SECONDCOAT O CONSIST OP APPLICATION ION Of TF¢•EPDXY COMING (SPEOULAR GLOSS 35-40%MINMJI) y 7 PAPER TOEEL MIRROR - DISPENSER ipui30' 14x• a GB.TYP MIRROR IS' IN LENGTH 1 11 II II 12" 1 axe MIND k • y 36 �I C 3 el rr c Dc :. c 1 Nx' a GB.TIP ,>♦ x e GB.NP Si FLOOR NOTES 0 I �� Project Number: HANDI-SHIELD SCORCHING ' I I _ NEW WALL PARTITION V 0 �ACKEi I IBIn eeR BasE e V, - 04 - SCORcuING D 1 . F L O O R PLAN — FIRST F L O O R O (SEE METAL STUD WALL DETAIL) N T7PICAL d11 N� � JACKET File Number: MAH401A 137) SCALE: 1/8" = 11-0" O (VERIFY COLOR W/TENANPARTITIONS ` 'I. \ _-eII �IIII�III�LIIIII,IILI. Date: 2/20/2011 l, 96' / I ral OINSTALL ADA TOILET FIXURES 4 ACCES. 60° c DRAWING SET NO. 'N ® LEVER HDWR3ADAOAPPROVED AND ACCESSIBLE TOILET ROOM — E LE V A4.1 (MATCH BLDG. STANDARD FINISHES) SCALE 3/8" = 1'-0" \ / `\ / 1 ©lc J _ ©tcJ 2 0 II tLni LJ 0 z V � C�1 ____� rim z o /` ©IG—J 0 - at - 0" _ s ° - C/1 0. -S. 7. L.) BIW _ r—�I r—� _ W N - ©IL-J La.'-.-1 a" N M - 3 in M I O . 0 S DEMO NOTES 1 . DEMO PLAN — SECOND FLOOR O REMOITIONXISTING, NON-STRUCTURAL WALL SCALE: 1/SII = 11-0° © REMOVE DOORFRAME © REMOVE LIGHT FIXTURE - STRUCTURAL ENGINEER TO VERIFY ANY STRUCTURAL WALLS OR COLUMNS PRIOR TO DEMOLITION. - SAFE-OFF ALL ELECTRICAL(HIGH VOLT 4 LOW VOLT) PRIOR TO DEMOLITION CI—I UL DOORS ODOR SRA ERITES E I"'• SIZE DESCRIPTION DESC. I— al N 9-N WN lAj OQ w , uQ \ U J Q = 9= � N-1 RD RD ��o al of iEn z y, at >-0 /be, REMARKS 0 O "� A s ,Ia-e• w-e r z bilau rz -10z Z Q 0100 0_0z X WI QC1 l-3d")I6 •t3 mOz r-Oz :Oz z d WOz Q.OZ in WI iZ1/41II F-32 m)z r- .1 bp ROOM NM W H T S P MAT. FIN. TYPE E L MAT. FIN. O . .77-0T-- 200 LOCKSET H o � 201 • LOCKSET .c I 104 202 • LOCKSET o� �, �� �j I • F "N. o 203 • LOCKSET w casI a 120,1 204 LOCKSET �- .moi rn NOTE: DOOR HARDWARE TO BE GRADE 1, DORMA CLS00-LG OR APPROVED SUBSTITUTE (I i 203 ALL DOOR HARDWARE TO BE LEVER AND A.D.A. APPROVED, G2C FINISH `5 VERIFY ALL FINISHES W/TENANT � o � m li 111 Ill Mi 1 206 702 I WI 4 ATTACH W/(2) *8 WOOD SCREWS, TO NOTE: ANY WALL OVER SC0' LONG SMALL BE BRACED AS SHOUIN. FILES EXIST WOOD STRU. BRACING SHALL NOT SE ATTACHED 12 DelTO GRID SYSTEM. Revisions: s I ,a RILES 3%' 25 GA. MTL. STUD BRACES 20 11 N TO S�TRUCT. a 8'-0' 0/C - STAGGERED V \• (2) *8 SCREWS AT EACH END - 1 ` 1��I r a _____,----� qy-0' 14-8' A ACT CEILING TILE _ 1 STUD WALL IS NOT IONIZE DIRECTLY CONNECTED TO CEILING. w f 1" II ,I LI j 5/8' TYPE 'X' SHEETROCK ` 2 EACH SIDE )-- I 3%' MTL. STUDS /Project Number: \ LL 20-GAUGE ® 24' o/c. FLOOR NOTES w (362V5I25-20) 1 . FLOOR P LAN — SECOND FLOOR ,O BOTTOM TRACK ATT. TO MAH402A NEW WALL PARTITION File Number: (SEE METAL STUD WALL DETAIL) FLOOR ® 48' O/G W/ POWDER DRIVEN ANCHORS SCALE: I/811 =11-0a O INSTALL NEW BATHROOM PARTITIONS wl Date: 2/20/201"1 L (VERIFY COLOR W/TENANT) EXISTING FLOOR OINSTALL ADA TOILET FIXURES 4 ACCES. DRAWING SET NO. METAL STUD WALL DETAIL (TYP) 0 LEVER NDWR ADDOOR/FRAMEPRAND N.T.S A4.2 (MATCH BLDG. STANDARD FINISHES) \....... l J - - 1 I n n o- � n I i U I l n I _E.....„ [ .7..„........„.d __ 81 : r- e r E,,, ,,, _ _.>„...i i ___,. xfi 2 ZC V ,E,.....„...„---; E rn let � o / LUG. D t II �I��W j� E 7 v o Z —e ELM �I _ Z h L. D 01 _ TIPS Qa ® o. Ala o C t 1T . r--\\ ...----.....-...--.---a#2 _ S 0E mol ` ) o 0 E p�gT O e E 3. W fag. ® I ,E,„...„.... E E E ivi • CO L — I ± _: IE -- M a in ti LEIS EXISIGRID/TILEk 0 a. '�t - REMAIN.RELOCATE FIXTURES AS REQUIRED 11 I I II II S }REFLECTED CEILING LEGEND FLUORESCENT LAY-IN TYPE FIXTURE. 1 . RCP PLAN — FIRST FLOOR / (3) 32 WATT T-8 LAMPS WITH SINGLE ELEC. BALLAST • 'E' EXISTING SCALE: I/8"=11-C° 'R' RELOCATED 0 COMPACT FLUORESCENT RECESSED CAN LIGHT 120 V, (13 WATTS EACH) I I WALL MOUNTED FLUORESCENT FIXTURE O CEILING EXHAUST FAN (SEE MECHANICAL DRAWINGS FOR SIZING) 9 UNIVERSAL MOUNT EXIT TYPE FIXTURE. GREEN LED LAMPS SINGLE OR DOUBLE FACE WITH - DIRECTIONAL ARROW(S) WITH EMERGENCY BATTERY BACK-UP. _ EGRESS LIGHTING: THE MEANS OF EGRESS ILLUMINATION LEVEL SHALL NOT BE LESS THAN I FOOT-CANDLE, AVERAGE, AT THE FLOOR LEVEL DURING HOURS , OF OPERATION W/90 MIN. BATTERY BACKUP V n LIGHTING: MAINTAIN EXISTING SYSTEM n i-1 rn Oo CD al bp 4 I] I I ,i I n n---) 1 II I I II I 11 Ir."14I 4 E"I O ToT .E . M E _..........."" 7.......„.„-// E-d gt v OrleeI t ® ,� 104 0 - w E �ffi9L_ I.oCU / iei E of / e _ 0 2m2 / kliT ✓ P .12 FILES 12010Revisions: Revisions:,, j PILES .>„.... --- `/ . 12mm _ - I I 1I II II -11 I II I I CEILING GRID/TILE - IS EXISTING TO - REMAIN.RELOCATE FIXTURES t1 AS REQUIRED 1 II 1I 11 • J I r N\ Project Number: 2 . RCP PLAN — SECOND FLOOR File Number: MAI-1801A SCALE: 1/8" II-0" Date: 2/20/2011 DRAWING SET NO. A8.1