Loading...
Report (108) FIRE ALARM CONTROL PANEL REPLACEMENT SUBMITTAL GUIDE RECEIVED MAR 21 2016 CITY OF TIGARD BUILDING DIVISION WOODSPRING APARTMENTS BUILDING 11 16132 SW 113th AVE TIGARD, OR 97224 Prepared By: PERFORMANCE SYSTEMS INTEGRATION 7324 SW Durham Road Portland, Oregon 97224 info@psintegrated.com (503) 641-2222 Phone (503) 641-1464 Fax 3/3/2016 4 SILENT SK-2 & SK-2E Fire Alarm 410 KNIGHT Control Panel by Honeywell A flexible, powerful, cost-effective panel for fire protection applications. The SK-2 and SK-2E (SK-2/E) are two zone conventional fire alarm control panels (FACPs)that bring the latest in microprocessor technology to conventional fire controls. The SK-2 is a 120 VAC FACP and the SK-2E is a 240 VAC FACP. These FACPs provide reliable fire signaling protection for small-to medium-sized commercial, industrial, and institutional buildings. For more information about the SK-2/E system, or to locate your nearest source, please call 1-800-328-0103. Description • Selectable for System Sensor, The two zone SK-2/E is a 24 VDC Wheelock, and Gentex protocols FACP that provides two Class B • Selective silence feature allows initiatingdevice circuits and one Class manual silence of horns while strobes continue to flash on the same NAC �; � B notification appliance circuit(NAC). • Silent or audible walk test operation yam` The SK-2/E NAC protocol includes the mode / 's ability to silence audible devices while • Alarm verification selectable per zone r strobes continue to flash, using only a • Pro ram each zone for supervisory or �` '` single pair of wires. The SK-2/E is also g p �' compatible with conventional input fire with separate red and yellow �` LEDs devices such as two-and four-wire smoke detectors, pull stations, • Disable switches provided per zone waterflow devices, tamper switches and • Program NACS for 9 sir other normally-open contact devices. —Silence inhibit , Activation of a compatible smoke —Auto silence detector or any normally-open fire —Strobe synchronization alarm initiating device activates audible —Temporal or steady signal and visual signaling devices, illuminates —Silenceable or nonsilenceable SK-2 an indicating LED, sounds the piezo —Disable sounder at the FACP, activates the • Form C alarm and trouble relays NACs FACP alarm relay, and operates an • 3A total usable current 2.5A @ 24 VDC with standard optional module used to notify a remote transformer, power-limited station or initiate an auxiliary control ' Optional dress panel (PN SK-DP2/4) Signaling Current: 2.5A max with function. Electrical Specifications standard transformer EOL Resistor: 4.7K , 1/2 watt The SK-2/E is compatible with System SK-2 Primary AC: 120 VAC @ 50/60 Sensor°13 detectors providingHz, 2.3A Form C Relays Types: Trouble and alarm advanced features such as drift SK-2E Primary AC: 240 VAC @ 50 Hz, Contact Ratings: 2A @ 30 VAC, compensation, maintenance alert, and 1.15A resistive freeze warning.Automatic Wiring: 14 AWG (2.0 mm2)with 600 V Auxiliary Output synchronization of audio/visual devices insulation min Resettable is provided, using three selections for Initiating Device Circuits(IDCs) Operating Voltage: 24 VDC nominal manufacturer protocol. Operating Voltage: 22 VDC nominal; Current: 500 mA max, power-limited Features power-limited Standby Current: 4 mA • Two Style B (Class B) initiating Alarm Current: 15 mA min device circuits(IDCs) Short-circuit Current: 40 mA max • One Style Y(Class B) notification Loop Resistance: 100 max appliance circuit (NAC) EOL Resistor: 4.7K , 1/2 watt • Support for synchronization of standard ANSI audible signals and ADA compliant strobes per NFPA 72 • SK-2 & SK-2E Fire Control Panel Engineering Specifications The contractor shall provide a completely electrically supervised fire alarm control panel Silent Knight Model SK-2/E. The system shall contain a fire alarm control panel capable of operating and supervising smoke detection devices, alarm notification devices, and an on-board annunciator. It shall be compatible with a digital communicator accessory. The fire alarm control panel shall have a power limited supply, two Class B initiation circuits which shall accommodate heat detectors, smoke detectors, and manual pull stations. Smoke detection shall be achieved with either 2-or 4-wire detectors that are compatible with the system.The initiation inputs shall be programmable as 1)verification zones in which detectors are automatically reset one time before signaling an alarm condition; or 2)combination waterflow supervisory zones that allows the FACP to distinguish between an alarm switch (waterflow device)and a supervisory switch (tamper) installed on the same circuit. The FACP shall have one 2.5 amp programmable notification output. It shall have dedicated relays for alarm and trouble and a resettable power output rated at 500 mA. The FACP shall have an on-board annunciator to indicate alarm, supervisory, trouble, and maintenance conditions. The annunciator must include LEDs for AC, GENERAL TROUBLE,ALARM SILENCE, WALK TEST, EARTH FAULT,AND LOW BATTERY. The annunciator shall also contain LEDs to annunciate fire alarms, troubles, supervisory, and maintenance by zone. The FACP must be fully operational from the annunciator and include buttons for ACKNOWLEDGE,ALARM, SILENCE, RESET, and WALK TEST. The annunciator must also have separate DISABLE switches for each zone and notification circuit. Electrical Specifications (con't) Approvals Digital Communicator Accessories Battery NFPA 72; UL Listed; 5104B Type: Sealed lead acid only CSFM 7165-0559: 145; Six-Zone fire control communicator Charging Circuit: 27.6 VDC @ 0.8A MEA 297-01-E-3 max normal flat charge 5129 Charging Capacity: 7 AH Ordering Information Four channel slave fire communicator Size: 18 AH max allowed in FACP. SK-2 Larger batteries can housed 120 VAC Two Zone Conventional FACP in an RBB accessory cabinet Compatible Initiating and NAC SK-2E Devices 240 VAC Two Zone Conventional FACP See SK document PN 52612. Accessories Mechanical Specifications SK-DP2/4 Cabinet Backbox Dimensions: Dress Panel.Allows access to the 14.5"W x 15" H x 3" D panel controls but restricts access to (36.83 W x 38.10 H x 7.62 D cm) system wiring. Cabinet Door: SK-4XTM 14.677"W x 15.342" H x 0.375" D Transmitter Module. Provides a (37.28 W x 38.97 H x 0.95 D cm) supervised output for local energy Cabinet Color: Red municipal box transmitter and alarm Installation and trouble reverse polarity. The SK-2/E can be surface mounted RBB using two key slots at the top of the Remote Battery Box Accessory backbox and two additional 0.25" Cabinet. Use if back up batteries are diameter holes at the bottom, or semi- too large to fit into FACP cabinet. flush mounted using optional Trim Ring Dimensions: 16"W x 10"H x 6"D P/N TR-1-R (406 mm W x 254 mm H x 152 mm D) 01 SILENT This document is not intended to bet used for installation purposes.Wte try MADE IN AMERICA to keep our product information up-to-date and accurate.We cannot KNIGHT cover all specific applications or anticipate all requirements.All FORM#350304 Rev. D specifications are subject to change without notice. For more information, ©2012 Honeywell International Inc. by Honeywell contact Silent Knight 12 Clintonville Road, Northford,CT 06472-7161 Phone:(800)328-0103, Fax:(203)484-7118.www.silentknight.com • + PENTAIR FIBERGLASS til 1X"' SPECIFICATIONS ..:, • Compression-molded fiberglass material has excellent temperature and chemical resistance qualities and exhibits "'" outstanding Ph sicat properties,including high-impact `f resistance Fiberglass is easily punched,drilled,filed or sawed • Seamless foam-in-place gasket assures water-tight and dust- tight seat • Enclosure may be rotated 180 degrees for left and right hinging 0 • Molded-in drip shields are standard with each enclosure ;r . • Impact-resistant polycarbonate window is permanently bonded it ll in place • Fiberglass mounting brackets and stainless steel attachment I screws are provided with each enclosure • Unique hinge design allows for standard 180 degree door opening ' 440,1 with a maximum opening of 270 degrees { • Door hinges are replaceable } ` • Type 316 stainless steel quarter-turn latch.Optional keytocking or padlocking handle available. Molded-in DIN bosses • Molded bosses on door provide additional mounting provisions • Integral mountingrailsprovide infinitepanel adjustment front to 9 J back INDUSTRY STANDARDS • Optional data pocket is high-impact thermoplastic Mounting brackets required to meet UL/CSA external mounting FINISH requirements. Exterior surface painted light-gray acrylic enamel for enhanced UL 508A Listed;Type 3,3R,4,4X, 12, 13;File No.E61997 UV protection.Optional steel panels are painted white.Optional cUL Listed per CSA C22.2 No 94;Type 3,3R,4,4X, 12, 13; Fite No. stainless steel,aluminum,conductive and composite panels are E619977 unpainted. Enclosure flammability evaluated per UL 508A Window flammability evaluated per UL 508A ACCESSORIES Type 3,3R,4,4X, 12, 13 See also Accessories. NEMA/EEMAC T YP H2OMIT Vent Drains,Type 4X CSA File No.42186:Type 3,3R,4,4X, 12, 13 H2OMITT" Thermoelectric Dehumidifier IEC 60529,1P66 NOL-SEALERSTM Non-Metallic Hole Seals Meets NEMA Type 3RX requirements Panels for Type 3R,4,4X, 12 and 13 Enclosures APPLICATION Rack Angles(Type RAI Providing outstanding protection against corrosion and the MODIFICATION AND CUSTOMIZATION elements,the clean lines and molded,embossed design of ULTRXTM Hoffman excels at modifying and customizing products to fiberglass enclosures make them the most stylish and aesthetically your specifications.Contact your local Hoffman sates office or pleasing of their class.These enclosures feature hidden hinges,a distributor for complete information. padlocking capability for security,and flexible internal mounting options. BULLETIN:UX1 Standard Product .:112101,11114 ,;;ii: ::Zig,:lgtOlZkt0iik;lit*ita Kir,,,"it*,,, IttOfitntil%filalf%, '''':' ,N,:':;:!:Y,Vi 08504020 Solid 513 x 413 496 x 396 x 220 A20P16 8200169 432 x 330 359 x 459 - 186 297 14 286 387 20.20x16.26 14.53;216505920 8.66 17.00 x 12.99 14.13 x 18.07 - 7.32 11.69 0.75 11.26 15.24 UU504020W Window 513 x 413 496 x 20 820016 920P16C 439 x 330 359 x 459 386 x 286 186 297 19 286 387 20.20016.26 19.53 x 15.59 x 8.66 17.00012.99 14.13018.07 15.20011.26 7.32 11.69 0.75 11.26 15.24 UU606020 Solid 625 x 612 608 x 595 x 220 024P24 82402411 533 x 533 559 x 572 - 186 500 21 489 489 24.61 x 24.09 23.94 x 23.43 x 8.66 20.98 x 20.98 22.01 x 22.52 - 7.32 19.68 0.83 19.25 19.25 08606020W Window 625 x 612 608 x 595 x 220 A241124 824024G 533 x 533 559 x 572 498 x 486 186 500 21 489 489 24.61 x 24.09 23.94 x 23.43 x 8.66 20.98 x 20.98 22.01 x 22.52 19.61 x 19.13 7.32 19.68 0.83 19.25 19.25 UU605025 Solid 625 x 513 608 x 496 x 270 824020 424P206 533 x 4479;507202.44.61 x 20.20 23.94 x x 10.63 20.98 432 x 17.00 7 - 239 400 21 387 489 9.41 15.75 0.83 15.24 19.25 08685825W Window 62245 x 513 60804960 270 A24020 A240200 533 x 432 457 x 570 498 x 386 239 400 21 387 489 24.61 x 20.20 23.94 x 19.53 x 10.63 20.98 x 17.00 17.99 x 22.44 19.61 x 15.20 9.41 15.75 0.83 15.24 19.25 UU504030 Solid 513 x 412 496 x 395 x 321 A20P16 8200166 432 x 330 355 x 455 - 287 300 19 286 387 20.20 x t 6.22 14.53 x 15.55 x 12.64 17.00 x 12.99 13.98 0 17.91 - 11.30 11.81 0.75 11.26 15.24 08504030W Window 250132x0 412 496 x 395 x 321 620016 A200166 432 x 330 355 x 455 386 x 286 287 300 19 286 387 20.20 x 16.22 19.53 x 15.55 x 12.64 17.00 x 12.99 13.98 x 17.91 15.20 x 11.26 11.30 11.81 0.75 11.26 15.24 0U606030 Solid 625 x 612 608 x 595 x 321 824024 A24P24G 533 x 533 555 x 568 - 287 500 21 489 489 24.61 x 24.09 23.94 x 23.43 0 12.64 20.98 x 20.98 21.85 x 22.36 - 11.30 19.68 0.83 19.25 19.25 UU606030W Window 625 x 612 608 x 595 x 321 824P24 A240246 533 x 533 555 x 568 498 x 486 287 500 21 489 489 24.61 x 24.09 23.94 x 23.43 x 12.64 20.98 x 20.98 21.85 x 22.36 19.61 x 19.13 11.30 19.68 0.83 19.25 19.25 UU756030 Solid 775 x 612 758 x 595 x 321 830024 A300240 686 x 533 555 x 718 - 287 500 21 489 641 30.51 x 24.09 29.84 x 23.43 x 12.64 27.01 x 20.98 21.85 x 28.27 - 11.30 19.68 0.83 19.25 25.24 1 NON-METALLIC I SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION SOLUTIONS Spec-00402 H FIBERGLASS 11[14V0 W`+rf ' 0 00756030W Window 775 x 612 758 x;95'0 321 430924 6309246 686 x 533 555 x 718 648 x 486 287 500 21 489 641 30.51 x 24.09 29.84 x 23.43 x 12.64 27.01 x 20.98 21.85 x 28.27 25.51 x 19.13 11.30 19.68 0.83 19.25 25.24 UU1008030 Solid 1025 x 825 1008 x 808 x 321 640930 6409306 940 x 737 768 x 968 - 287 700 23 692 895 40.35 x 32.48 39.68 x 31.81 0 12.64 37.01 x 29.02 30.24 x 38.11 - 11.30 27.56 0.91 27.24 35.24 001008030W Window 1025 x 825 1008 x 808 x 321 640930 6409300 940 x 737 768 x 968 898 x 698 287 700 23 692 895 40.35 x 32.48 39.68 x 31.81 x 12.64 37.01 x 29.02 30.24 x 38.11 35.35 x 27.48 11.30 27.56 0.91 27.24 35.24 UU606040 Solid 625 x 612 608 x 595 x 421 624924 6249246 533 x 533 555 x 568 - 387 500 21 489 489 24.61 x 24.09 23.94 x 23.43 x 16.57 20.98 x 20.98 21.85 x 22.36 - 15.24 19.68 0.83 19.25 19.25 80606040W Window 6224580i 612 608 x 5092530443201 624924 6249246 533 x 533 555 x 568 498 x 486 387 500 21 489 489 24.41 x 24.04 23.94 3 14.57 20.98 x 20.98 21.85 x 22.36 19.61019.13 15.24 19.68 0.83 19.25 19.25 UU756040 Solid 775 x 612 72588804 5073x44320118.02 630924 6309246 684 x 533 52515.87;(1:8.22 - 387 500 21 484 441 30.51 24,04 29.84 . 27.01 x 20.98 - 15.24 19.68 0.83 19.25 25.24 99756040W Window 775 x 612 758 x 595 x 421 630924 6309246 686 x 533 555 x 718 648 x 486 387 500 21 489 641 30.51 x 24.09 29.84 x 23.43 x 16.57 27.01 x 20.98 21.85 x 28.27 25.51 x 19.13 15.24 19.68 0.83 19.25 25.24 Purchase panels separately. Note:When installing enclosures in a right-hand hinge application that involves vibration,Hoffman recommends the use of pad-locking or key-locking quarter-turn latch accessories for door securement(UUHPt.,UUHKU. W B _ 64 mm N 64 mm 2.52 2.52 S -__ 38 mm . 1.48 MMMMMEEMMMMM Q Q, i i.2 , SCREW SLOT PANEL i_ 25 mm�.� LINE OF I LATCH RELEASE (ORDER .98 ,, MAXIMUM 1 SEPARATELY) 38 mm :1USEABLE CENTER HINGE u M L III,.. ., D 1.48 AREAOW I OMIT IF 'L• IS I i T X 1STH4N 775 mm X I I ,- A __ __ 30.51 __ IIIit IR 3 mm CENTER BOSSES E •, 12 OMIT IF W' IS ;1 (TYP) LESS THAN 612 mm i!.iI 24.11K4 ZaJ FRONT VIEW ` J J G I 39 rm 1.53 FRONT VIEW WITH DOOR REMOVED t ;iyp= . ir-J, f II C+8 mm 4 mm C .31 .15 I ..I��rr�NI.�. 28 mm fl i� ',- CO3/8-16 LLAR PANEL 1.10 MOUNTING BRACKET STUD (ORDER SEPARATELY) OPTIONAL POSTION (10 mm) SECT ION X-X FOR MOUNTING BRACKET 02553-C BACK VIEW EQUIPMENT PROTECTION SOLUTIONS PH 763 42 2.2211 •FAX 763.422.2600•HOFFMANONLINE.COM 1 NON-METALLIC 2 Spec-00402 H . 4k PENTAIR FIBERGLASS ET445 ®� MPG ULTRX Panel Bracket Kit 4 e.10 2.00 a= V 0Syyo- 1 1.75 .38-16 BOLT -I 44rrm10 LJ SPACER Panel Bracket Kit is used with steel panels and permits panel I'I adjustment from front to rear.Fits alt ULTRX sizes. Mounts on integrally molded body rail.Brackets are plated steel.All mounting 2.00 hardware is included.Note:Front mounting position is approximately 51 rrrn \ 1.50 140mm/5.5 in.back on 400mm enclosures. >,,38 38 mm BULLETIN:UX1Y 87792343 SWING-OUT PANEL ;, rl' UU5048SP 513x413 432 330 20.20 x16.26 17.00 12.99 ' -4 UU6050SP 625 x 513 536 432 L� 24.61 x 20.20 21,10 17.00 UU6060SP 625 x 612 540 535 ' 24.61 x 24.09 21.25 21.08 UU7560SP 775 x 612 687 535 ; 30.51 x 24.09 27.05 21.08 , UU10080SP 1025 x 825 935 737 ; + 40.35 x 32.48 36.80 29.00 , , � -j ; Use UU6060SP with DATACOM ULTRX Fiberglass Type 4X WiFi Cabinet. j\ \ .75 �``19 mn QUARTER—TURN .(411444444%LATCH L Installs front-mounted panels in ULTRX fiberglass enclosures.The 1 front-mounted swing panel complements window-door units and is suited for any application requiring a display of gauges,dials or any type of control equipment monitor.Made of 14 gauge plated steel. Easy installation;no drilling required.Fully adjustable front to rear. Panel and mounting hardware included. Note:Front mounting position is approximately 140mm/5.5 in.back on W C2562-C 400mm enclosures. BULLETIN:UX1Y Grounding Device provides a means to attach a grounding conductor to an ULTRX Swing-Out Panel or Swing-Out Frame.Includes all o installation hardware and instructions. a a P' 0 BULLETIN:UX1Y 0 ° 0 UUGK� ULTRX Grounding Device ° 2/%...re 0 a °0aa° °o 0 °°°° 3 NON-METALLIC I SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION SOLUTIONS Spec-00402 H FIBERGLASS 1111 " �� PANELS FOR TYRE 3R,4,4X, 12 AND 13 ENCLOSURES ., Steel panels are 12 gauge with a white finish.Pa net mounting hardware is furnished with all enclosures which accept these ,, panels. A20116 12 1700x13.00 432 x330 4 0 A24P20 - 0.75 19 21.00 x 17.00 533 x 432 4 2 A24P24 - 0.75 19 21.00 x 21.00 533 x 533 4 2 • A24P24WD - 0.75 19 21.00 x 21.00 533 x 533 4 - BULLETIN:DWS12,PNLWM A30P24 - 0.75 19 27.00x21.00 686x533 4 2 A40P30 - 0.75 19 37.00 x 29.00 940 x 737 4 4 Catalog number with"WO"is wood. I- 0.50 I EDGE FLANGES 13 mm T IF NECESSARY (TYP) (SEE TABLE) 95.28 GND 7 mm HOLE T (SEE CHART) CENTER HOLES ONLY ON PANELS WITH •D' GREATER D , 40 30.00 763 mm 1.25 32 mm iL CENTER HOLES 1111 ; ONLY ON PANELS 1111 THAN '0' GREATER THAN 30.00 # 762 mm .88 � y .88 II T C2606-C 22 mm IF 22 mm E PACK ANi31EA: !TYRE A) ..,.. UURA6060 610x610 552 10 12 2 24.00 x 24.00 21.75 .38 UURA7560 762x610 705 19 15 2 30.00 x 24.00 27.75 .75 Use UURA6060 with DATACOM ULTRX Fiberglass Type 4X WiFi Cabinet. / frU1 88 25 Pairs of full-length rack-mounting angles are available for mounting 1-in.(483-mm)rack-mounted equipment.Type RA angles are 14 gauge steel with.281-in.(7-mm)diameter mounting holes, L spaced per EIA standard RS-31t3-D(universal.spacing).Use Clip 6 25n 4, rrr Nut Package(AN1032)to provide tapped holes at desired locations. Angles and mounting hardware are plated steel.Mounting N hardware is furnished. .62 -.50 16 mm 13 mm BULLETIN:UX1Y .62 87792473 16 mm EQUIPMENT PROTECTION SOLUTIONS PH 763.422.2211 •FAX 763.422.2 600•HOFFMANONLINE.COM I NON-METALLIC 4 Spec-00402 H * + PENTAIR FIBERGLASS ii[RP KEY CK KIT AND PADLOCK KIT - .96 .96 1 24 mm 24 mm 1 7 ‘ ' •' ' 2.39 ' 2.39 ® 0 61 mm 61 mm Keylock Kit or pushbutton-style Padlock Kit is easily inserted in \ r\ \` 9 r\ latch hole to prevent unauthorized personnel from gaining access to enclosure contents.Each kit is fully assembled for easy installation 1.14 0-40 1.14 in the field.Type 316 stainless steel construction. 29 m 10 mm 29 mm BULLETIN:UX1Y Keylock Kit Padlock Kit UUHKL Keylock Kit 87792346 UUHPL Padlock Kit UUHKL:Internal key components are not stainless steel. UUHPL:Handles maintain UL 508A,Type 3,4,4X and 12 when property installed on a Hoffman enclosure.Set up for 1/4-in.or 3/8-in.padlock. UU6060SF 610 x 610 540 535 11 24.00 x 24.00 21.25 21.08 UU7560SF 762 x 610 687 535 14 30.00 x 24.00 27.05 21.08 Use UU6060SF with DATACOM ULTRX Fiberglass Type 48 WiFi Cabinet. W Swing Frame provides 19-in-rack-mounting capabilities with U-Style(Type RA)mounting hole pattern.Quarter-turn latch has 100-degree swing.Adjustable mounting provision. 14 gauge plated steel.Includes mounting hardware.Swing frame maintains enclosure rating if properly installed in a Hoffman enclosure. L Note:Front mounting position is approximately 740mm/5.5 in.back on ✓/ 400mm enclosures. j C2563-C BULLETIN:UX1Y 5 NON-METALLIC ( SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION SOLUTIONS Spec-00402 H FIBERGLASS UURXr" " DOOR STOP KIT 9 1 Door Stop Kit limits door to , 120-degree opening.Field a� installable on all sizes of ULTRX UUDS Door Stop Kit n �� enclosures.Type 304 stainless steel e construction. BULLETIN:UX1Y 111 TPYVA 1,(1.7.!pear•,;-r r Inserts can be substituted for the standard quarter-turn Latch.Inserts � z are Type 316 stainless steel. UUL3DB Double-bit 3mm UULSC Screwdriver slot BULLETIN:UX1Y I BURST' BOCK-GNP BRACKET KIT Kit is field-installable.Corrosion- �i resistant fiberglass material. Q Type 316 stainless steel mounting UUMF Mounting Bracket Kit 4,. hardware is included.Four mounting brackets per kit. 0.41 ° 2 x BULLETIN:UX1Y .53 — J 13 rmI \ 1 .533 � 39 rrrn 11059177 SCREW INSERT KIT Brass threaded inserts(10-32(with4. t y plated screws.Used on door bosses UUMH2 Screw Insert Kitdin es�tsand4screws lir and DIN bosses. BULLETIN:UX1Y SELF-TAPPING SCREWS "K' Plated screws(1/4-15 x.881 mount panels and accessories to DIN UUMH1 Self-Tapping Screws 10 bosses on back of enclosure. Pp g BULLETIN:UX1Y Ors eftEQUIPMENT PROTECTION SOLUTIONS PH 763,422.2211 •FAX 763.422.2600•HOFFMANONLINE.COM NON-METALLIC 6 Spec-00402 H l' 4. ��// .: �f fi/dj c it 4fig ,,,,, 7 ,,,,,,,r. w ' ,./ ,=-',.- - '':-,,-, • ,., ,';:'2' : '',,,; t - :,''''.j. - ',,'-;;.,741,2 t ,amu; ��- ( "i'" ���„iJ �, ra,w,� .'F,bYLO///(// � ,. ,i . ✓ f jf'q$ n sx fir/ � ;.,,E i _...,..r---..,...1 __ .a m ,# ce' ✓ %ice;, 1 ..... Werker SLA technology offers high-density power that out-performs traditional lead acid batteries. The Absorbed Glass Mat(AGM)construction is designed for efficient gas recombination and allows for maintenance-free operation. Werker SLA batteries maintain their high capacity with a design that is resistant to damage caused by deep discharge.Every Werker SLA battery is inspected to ensure the highest standards in materials and fabrication. Battery Features: Charger Features: • Werker SLA AGM batteries contain a proprietary grid alloy New! SLA Chargers formula.This formula combined with the advanced plate curing techniques offer improved performance. • Regulated trickle charge for"float" mode charging • Werker batteries contain a unique electrolyte formula with a • Short circuit protected special sub-colloid additive for higher reliability and longer life. • Reverse polarity protected • More than 1,000 discharge/recharge cycles. • Thermal protection in case of overload • The unique construction and sealing techniques of the Werker • Alligator clips battery guarantee leak-proof operation. • Color LED to indicate state of charger • Heavy-duty lead calcium tin alloy grids provide an extra margin of performance and service life in cyclic applications, even after repeated over-discharges. • Quality Assurance Engineers monitor and control the entire • �, ' � rr production process. Wer r k e r. (143,0q)ssx SLA/AGM BATTERIES Flame Capacity Dimensions Height Over Weight Flame Capacity Dimensions Height Over Weight Item# Volts Retardant Ah L x W x H(in.) Terminal(in.) (lbs.) Item# Volts Retardant Ah L x W x H(in.) Terminal(in.) (lbs.) WKAl2-0.8WL 12 - 0.8 3.78x 0.9842.40 2.4 0.8 WKAl2-7.5F2 12 - 7.5 5.94 x 2.56 x 3.74 3.98 6.0 WKAl2-1.3F 12 1.3 3.82 x 1.69 4 2.05 2.28 1.4 WKAl2-12F2 12 - 12 5.94x3.904374 3.98 9.3 WKA1 2-2ST 12 - 2 5.91 x 0.79 x 3.54 3.54 1.7 WKAl2-18NBL 12 - 18 7.13x3.03x6.57 6.57 13.9 WKAl2-2.3F 12 - 2.3 6.97 x 1.38 x 2.40 2.64 2.0 WKAl2-26NB 12 - 26 6.50 x 6.93 x 4.92 4.92 20.3 WKAl2_3.3F 12 - 3.2 5.2842.64x2.40 2.64 3,2 WKAl2-33C 12 - 35 7.72 x5.16 x6.10 6.57 25.4 WKAl2-5.1A 12 - 4.5 5.51 4 1,89 4 3.98 421 4.4 WKA1 2-33J 12 - 35 7.72 x 5.16 x 6.10 7.09 25.4 WKAl2-5F 12 - 5 3.54 x 2.76 x 3.98 421 4.0 WKAl2-44C/FR 12 Y 45 7.80 x 6.54 x 6.85 6.85 35 7 WKAl2-7.5F 12 - 7.5 5.94 4 2.56 4 3.74 3.98 6,0 WKAl2-550/FR 12 Y 60 9.02 4 5.43 4 8.19 8.35 40.3 Continued on Next Page For more information please contact: Re . lacement • ,,.•. • ,® • „, ; www,ReplacementUPSbattery.corn Phone: 952-217-6611 Email: info@replacementupsbattery.com Continued from Previous Page Page 2 SLA/AGM BATTERIES Flame Capacity Dimensions Height Over Weight Flame Capacity Dimensions Height Over Weight _ hem# Volts Retardant Ah L x W a H(in.) Terminal(in.) (lbs.) hem 0 Volts Retardant Alt I x W e H lin.) Terminal(in.) (lbs.) WKAl2 55P/FR 12 V 60 9.02 x 5.43 x 8.19 9.06 40.3 WKA6-14A 6 - 14 4.25 a 2.80 x 5.51 5.51 6.2 WKAl2-80C/FR 12 V 80 10.24 x 6.65 x 8.31 8.46 55.1 WKA6-14T1 6 - 14 4.25 x 2.80 x 5.51 5.51 6.2 WKAl2-80J/FR 12 Y 80 10.24 x 6.65 x 8.31 9.06 55.1 WKA6-14T2 6 - 14 4.25 x 2.80 x 5.51 5,51 6.2 • WKAl2-100C/FR 12 V 100 12.09 x 6.65 x 8.31 8.46 72.8 WKA6-1413 6 - 14 4.25 x 2.80 x 5.51 5.51 6.2 WKAl2-100J/FR 12 V 100 12.09 a 6.65 x 8.31 9.06 72.8 WKA6-42F2 6 42 6.38 x 3,46 x 6.42 6.69 15.9 WKAl2-125C/FR 12 Y 140 13.43 x 6.81 a 11.06 11.3 104.7 WK46-42N9 6 - 42 6.38 x 3.46 x 6.42 6.85 15.9 WKA6-1.3F 6 - 1.3 3.82 x 0.94 x 2.05 2.28 0.7 WKA4-4.5F2 4 - 4.5 1.85 x 1.85 x 3.98 4,21 1.3 WKA6-3.3F 6 3.2 5.28 x 1.34 x 2.40 2,64 1.6 WKA6-5F 6 - 5 2,76 x 1,85 x 3,98 4.21 2.1 WERKER SLA CHARGERS WKA6-5SP 6 - 5 2.64 x 2.64 x 3.82 4,53 2.0 Dimensions Weight WKA6-7.2F 6 - 7,2 5.94 x 1.34 x 3.74 3,98 3.0 hem* Volts mA lx W a H(in.) (lbs.) WKA6-8.2F 6 - 8.2 3.90 x 2.24 x 4.53 4.53 3.8 WK6V500 6V 500mA 2,36 x 2.04 a.73 0.58 WKA6-10F 6 - 10 5.94 x 1.97 x 3.74 3.98 4.4 WKl 2V500 12V 500mA 2,36 x 2.04 a.73 0.66 WKA6-12F 6 - 12 5.94 a 1.97 x 3.74 3.98 4.6 WK6V1000 6V 1000mA 2.54 x 2.32 x 1.95 0.86 WKA6-12F2 6 - 12 5.94 x 1.97 x 3.74 3.98 4.6 WK12V1000 12V 1000mA 2.54 x 2.32 x 1.95 1.00