Plans (4) F PS2017 - OO 129 1 cg q) QE Q O,_ _ O€ 2 IC9u �� Z C, 00 A h� Lu- toc w\ Z a W (i) m 0 CtCc; a O W Qd L U � � d c LINCOLN 2 �� L mooOmo. Orn 00.-, .2 m WOc CO F' 2Vw N col 4TH o LS wl- 1. Ebn FL0oR _ surTE 450 3 Rece iv, i FIRE ALARM AUG 142017 Bucin, oinifl AHD SioN z.il SITE INSTALLER DRAWING INDEX E DWG# DESCRIPTION LINCOLN 2 CAPITOL ELECTRIC FA-001 COVER SHEET 0, 10220 SW GREENBURG RD 11401 NE MARX ST FA-002 INFORMATION 4TH FA-101 4THFLOOR DEVICE PLACEMENT PLAN, NAC4 LAYOUT & CALCS E g TIGARD , OR 97223 PORTLAND , OR 97220 FA-701 WIRINGIPICALS PHONE : 503-516-2233 8. CONTACT: SHANE TERCEK 3 s 2 Q OWNER ib SHORENSTEIN REALTY SERVICES - 10220 SW GREENBURG RD C RL- CITY OF TIGARD TIGARD , 09 722 3 REVIEWED FOR COti CD e Approved: ',---4— 0 ck Address: 0ZZO -\ W I— Tils Suite#: 4%40 ,' A,r __4 trtJ _ ByWs' Date: t 0 2 irA en S0 s b- t I OL OFFICE COPY ex N m - M N C = Z wrn is - JO N0 � —1wo 51 v = OoCt U L. ZN Q Z No 0J d- __jr H Si o a w J3 LL o s S Q I- z Q W 2 a Eli` �' E <> 3 H O 3 '- :00: n tilt/3 . :::0": - a. 6305 SW ROSEWOOD ST, SUITE A o N LAKE OSWEGO, OR 97035 w Y CO M0 N 610 a PHONE: 503-683-9000 0 z DRAWN BY: R. HERMANT - SERVICE: 503-683-9001 CHECKED BY: M. GERRONE = g FAX: 503-675-6521 oB#DATE: 8,10,17 c PROJECT* 448..601195001 s SIMPLEXGRINNELL© 2017 Safer. Smarter. Tyco. TM SYSTEM L E FIRE ALARM SYSTEM r SHEET: E z SALES REPRESENTATIVE DRAWINGS PREPARED BY SCHEDULING COVER SHEET 1E BRYAN ADAMS MARIA GERRONE FAITH KASKE _E z'9 ali 503-683-9000 NICET LEVEL III #126987 503-683-9000 0 Mgerrone@simplexgrinnell .com fkaske@simplexgrinnell .com FA-001 a lN 2 ININftil ,T, C GE\ ERAS \ OYES SYSTEv DESCI9TO \ / SCONE OF WORD SYvBOL BEY O O N 0LO , `Cr.Niiit )( o M foulalft co r-- .: (h M � O O C OCCUPANCY TYPE: B BUSINESS GROUP II 1. THESE DRAWINGS DEPICT GENERAL LOCATIONS OF LIFE SAFEIY EQUIPMENT & FIELD DEVICES. EXACT ROUTING OF Z CONDUITS TO BE DETERMINED IN THE FIELD BY THE INSTALLING CONTRACTOR TO SUIT CONDITIONS. ALL CHANGES % O j� 3 SHALL BE CLEARLY INDICATED ON THE RECORD DRAWINGS. SPRINKLER PROTECTION: BUILDING IS FULLY SPRINKLED FIRE ALARM SYMBOLS LEGEND `� o w�� 2. SHOULD ANY CONDITIONS EXIST THAT DIFFER FROM WHAT IS INDICATED ON THESE DRAWINGS WHICH CAUSE MAJOR v DEVIATIONS IN THE WORK SHOWN, THE CONTRACTOR SHALL CONTACT SIMPLEXGRINNELL IN A TIMELY MANNER SO AS NOT MODIFY EXISTING FIRE ALARM SYSTEM: PROVIDE NEW DEVICES AS SHOWN ON DRAWINGS. COMMONLY USED 3ACKBOX, REFER I'-' ,� TO IMPAIR THE CONSTRUCTION SCHEDULE. SYMBOL DESCRIPTION MODEL ci3 ��,_ 3. CONTRACTOR IS RESPONSIBLE FOR MAKING AND OBTAINING APPROVAL FOR ALL NECESSARY ADJUSTMENTS IN CIRCUITING DESIGN IS FOR ARE ALARM NOTIFICATION OF SUITE 450. TO DATA SHEET FOR OTHER OPTIONS o,o N AS REQUIRED TO ACCOMMODATE THE RELOCATION OF EQUIPMENT AND/OR DEVICES WHICH ARE AFFECTED BY ANY C4 t ooM I NAC EXTENDER PANEL ' AUTHORIZED CHANGE. ALL CHANGES SHALL BE CLEARLY INDICATED ON THE RECORD DRAWINGS. ALL NEW WIRING TO BE CLASS B. NAC4 i DESIGNATES THE NAC PANEL NUMBER SIMPLEX 4009-9201 !SUPPLIED BY SIMPLEXGRINNELL E ct co cno o 4. A STAMPED SET OF APPROVED FIRE ALARM DRAWINGS SHALL BE AT THE JOB SITE AND SHALL BE USED FOR I; o w; INSTALLATION. THE EXISTING FIRE ALARM SYSTEM SHALL NOT BE DISCONNECTED OR TAKEN OUT OF SERVICE IW / 6.2AH BATTERY SET SIMPLEX 2081-9272 ( c�LL; 5. THE POWER CIRCUIT TO THE FACP AND TO THE FIRE ALARM POWER SUPPLIES SHALL BE ON A DEDICATED 120V, 20A WITHOUT WRITTEN PERMISSION FROM THE OWNER. IT IS THE CONTRACTOR'S RESPONSIBILITY TO I SMOKE SENSOR / BASE SIMPLEX 4098-9714 iaj cc `,;;�w> BRANCH CIRCUIT BREAKER, AND SHALL HAVE A RED MARKING, LOCK-ON PROVISION AND SHALL BE IDENTIFIED AS "FIRE COORDINATE WITH THE OWNER THE TIMING OF ANY EXISTING FIRE ALARM SYSTEM DEMOLITION WORK. ,� y' I- o � �J { SIMPLEX 4098-9792 BASE 14" OCTAGONAL BOX 1 1/2" DEEP a _1 0 ALARM CIRCUIT CONTROL." THE LOCATION OF THE CIRCUIT DISCONNECT MEANS (CIRCUIT BREAKER) SHALL BE I I N PERMANENTLY IDENTIFIED AT THE FIRE ALARM CONTROL UNIT. . 6. UPDATE THE AS-BUILT DRAWING SET DAILY WITH JOB PROGRESS. RETURN THE AS-BUILT DRAWING SET TO I SIMPLEXGRINNELL NO LATER THAN 7 DAYS AFTER FINAL TEST. j F IMANUAL PULL STATION SIMPLEX 4099-9001 SINGLE GANG BOX 2 1/2" DEEP 14 7. THE CONTRACTOR WILL MAINTAIN ALL AREAS OF THE BUILDING IN A NEAT AND WORKMAN LIKE MANNER. 8. DO NOT APPLY POWER EXCEPT IN THE PRESENCE OF A FACTORY TRAINED SIMPLEXGRINNELL TECHNICAL REPRESENTATIVE. i 9. ANY SMOKE DETECTOR HEAD INSTALLED BEFORE THE BUILDING IS CLEANED AND ACCEPTED SHALL BE COVERED TO 1/2" PROTECT FROM DUST. ANY FALSE ALARMS DUE TO DIRT CONTAMINATED HEADS SHALL BE THE RESPONSIBILITY OF THE ® WALL MOUNT MULTI-CANDELA V/O WHITE SIMPLEX 4906-9103 4" SQUARE BOX 1 DEEP FIRE ALARM INSTALLER. # =CANDELA RATING W/4905-9940 ADAPTER SKIRT WHEN SURFACE MOUNTED E. 10. THE FIRE ALARM INSTALLER WILL MAINTAIN THE FIRE RESISTANCE INTEGRITY OF ALL WALL, CEILING, AND ROOF ASSEMBLIES ANY TIME THAT WORK IS NOT ACTIVELY BEING PERFORMED. ^ 11. INSTALLATION OF DEVICES SHALL BE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. POWER LIMITED AND ( I CEILING NON-POWER LIMITED FIELD WIRING MUST BE INSTALLED WITHIN THE FACP ENCLOSURE IN ACCORDANCE WITH C MOUNT MULTI-CANDELA V/O WHITE SIMPLEX 4906-910 HANDY BOX 1 1/2" DEEP I # =CANDELA RATING MANUFACTURER'S INSTRUCTIONS AND NEC. FI ` IE ALAR V ADL. CABLE C D 3 E S (Sc STA \ DADS 12. ALL WIRING SHALL BE INSTALLED ACCORDING TO NFPA 70 (NEC). I CEILING MOUNT MULTI-CANDELA A/V WHITE SIMPLEX 4906-9130 { 4" SQUARE BOX 1 1/2" DEEP 13. ARE ALARM CIRCUITS SHALL BE IDENTIFIED IN ACCORDANCE WITH APPROPRIATE SECTION OF NEC 760. MARK ALL FIRE C 1 # =CANDELA RATING I - ALARM WIRES IN ACCORDANCE WITH NEC 760 SECTIONS FOR POWER LIMITED AND NON-POWER LIMITED WIRE. - 14 ARE ALARM CABLE INSTALLED IN DUCTS, PLENUM, AND OTHER SPACES USED FOR ENVIRONMENTAL AIR SHALL BE TYPE FPLP. WALL MOUNT MULTI-CANDELA A/V WHITE SIMPLEX 4906-9129 4" SQUARE BOX 1 1/2" DEEP o 15. FIRE ALARM CABLE INSTALLED IN THE VERTICAL RUNS AND PENETRATING MORE THAN ONE FLOOR OR CABLES INSTALLED OREGON FIRE CODE, 2014 EDITION # =CANDELA RATING W/4905-9940 ADAPTER SKIRT WHEN SURFACE MOUNTED IN VERTICAL RUNS IN SHAFTS SHALL BE TYPE FPLR. zf,E 16. FIRE ALARM CABLE INSTALLED IN UNDERGROUND CONDUIT OR OTHER WET LOCATIONS SHALL BE UL LISTED FOR WET OREGON MECHANICAL SPECIALTY CODE, 2014 EDITION ' LOCATIONS. J I JUNCTION/PULL BOX SUPPLIED BY OTHERS ' SUPPLIED BY OTHERS 17. FIRE ALARM CIRCUITS EXTENDING BEYOND ONE BUILDING AND RUN OUTDOORS SHALL BE INSTALLED IN ACCORDANCE OREGON ELECTRICAL SPECIALTY CODE, 2014 EDITION I WITH NFPA 70 ARTICLES 760, 770, 725 AND 800 WHERE APPLICABLE. END-OF-LINE RESISTOR 3.3K (EOL) SIMPLEX 4081-9002 E 18. ALL WIRING, INCLUDING SHIELDS MUST BE DRY AND FREE OF SHORTS AND GROUNDS. NATIONAL FIRE ALARM CODE (NFPA 72), 2013 EDITION #K END-OF-LINE RESISTOR 4.7K (EOL) SIMPLEX 4081-9003 19. ALL SHIELDED WIRE MUST HAVE SHIELD CONTINUITY AT FULL LENGTH OF THE WIRE. 20. ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT. END-OF-LINE RESISTOR 6.8K (EOL) SIMPLEX 4081-9004 21. 120VAC IS NOT PERMITTED IN THE SAME CONDUIT WITH LOW VOLTAGE WIRING. END-OF-LINE RESISTOR 10K (EOL) SIMPLEX 4081-9008 22. MAINTAIN 40 PERCENT MAXIMUM CONDUIT FILL RATIO AS PER NEC REQUIREMENTS. 23. EXISTING CONDUITS MAY BE USED BY THE INSTALLATION CONTRACTOR AS DEEMED NECESSARY, HOWEVER, ANY EXISTING NOTE: EXISTING DEVICES SHOWN SHADED FOR REFERENCE. e CONDUIT WILL BE USED ONLY IF CONDUITS MEET CURRENT STANDARDS AND CODES. SIMPLEXGRINNELL MAKES NO - STATEMENTS WRITTEN OR VERBAL AS TO THE CONDITION OF EXISTING CONDUITS. a U LI L O C O I o U JURISDICTIONS WITHIN THE STATE MAY HAVE AMENDMENTS TO THE STATE ADOPTED CODE. c. CHECK WITH THE LOCAL JURISDICTION AUTHORITY FOR MORE DETAILS. s m a W SC - EDJL` ABBEVIATIO \ S =G - \ D RISER �IIAGAV 3 L O GENERAL NOTES: 0 AC = ABOVE CEILING HT = HEIGHT 1. DEVICES SHOWN ARE TYPICAL SEE FLOOR PLAN FOR QUANTITY AND LOCATION. C = CEILING MOUNTED HVAC = HEATING, VENTILATION, & AIR CONDITIONING 2. ALL WIRING SHALL COMPLY WITH NFPA 70, ARTICLE 760, POWER UMITED SYSTEMS. L E = EXISTING TO REMAIN IMS = INFORMATION MANAGEMENT SYSTEM 3. EXISTING DEVICES SHOWN SHADED FOR REFERENCE. o 0 RC = EXISTING TO REMOVE AND COVER MAX = MAXIMUM RD = EXISTING DEVICE TO BE RELOCATED MIN = MINIMUM H RL = RELOCATED DEVICE N/A = NOT APPLICABLE RR = REMOVE EXISTING AND REPLACE W/NEW NAC = NOTIFICATION APPLIANCE CIRCUIT EXTENDER -`J NDU = NETWORK DISPLAY UNIT (1:NAC4:V1),\ 47‘..,__(. , 1:NAC4V1 0 WP = WEATHERPROOF NEC = NATIONAL ELECTRICAL CODE 10K �� �/��� ;C �-'SI 0 XP = EXPLOSION PROOF NFPA = NATIONAL FIRE PROTECTION ASSOCIATION 'v -V H = HIGH HUMIDITY NIC = NOT IN CONTRACT I I (1:NAC4:2) t ® ;10K " �)� 0 1:NAC4:V2 AFF = ABOVE FINISHED FLOOR NPU = NETWORK PROCESSING UNIT FH E A_AR N WI E LIST AHJ = AUTHORITY HAVING JURISDICTION NTS = NOT TO SCALE 1 (1:NAC4:V3)�,A,� c Ig I r 1:NAC4:V3 ALM = ALARM PAP = PRE-ACTION PANEL 10K "" J ' �L�I CIRCUIT DESCRIPTION RISER RATED: FPLR SINGLE CONDUCTOR(THHN,TFFN) PLENUM RATED: FPLP ANN = ANNUNCIATOR SCC = STATUS COMMAND CENTERI I I O V VISUAL/SIGNAL CIRCUIT SG ANIX./PAIGE 454718ARE SG ANIX./PAIGE 454719ARE BMS = BUILDING MANAGEMENT SYSTEM SLC = SIGNALING LINE CIRCUIT 1:NAC4:V4 2 CONDUCTOR 14 AWG AREA=0.0380 SQ. INCH AREA=0.0333 SQ. INCH CBC = CALIFORNIA BUILDING CODE SMK = SMOKESPARE I SUITE 450 L17) 6- CD = (eg. H SOLID ANIXTER FA-1402C-1-1N-03-BX NUMBER MRAREA 10.0097 SQ. INCH (EACH) FA4 AWG IX1402C-1 NUMBER 03 CSFM = CALIFORNIA) STATEDE FIRE MARSHAL SUPV = TAC = TRUEALEROTRADDRESSABLE CONTROLLER o DET = DETECTOR TRBL = TROUBLE I R Li_ CONDUIT SIZE CONDUCTOR AREA CONDUIT SIZE CONDUCTOR AREA DGP - DATA GATHERING PANEL TS = TAMPER SWITCH NAC4 w 1/2" 0.12 SQ INCH * 1-1/4" 0.60 SQ INCH * EOL END OF LINE TYP = TYPICAL ;� 3/4" 0.21 SQ INCH * 1-1/2" 0.82 SQ INCH = 4009 o 1" 0.34 SQ INCH * 2" 1.34 SQ INCH * EPO = EMERGENCY POWER OFF UON = UNLESS OTHERWISE NOTED E," FACP = FIRE ALARM CONTROL PANEL VCC = VOICE COMMAND CENTER I al * 40% FILL PER N.E.C. VT = VALVE TAMPER ! JANITOR'S 0 ` FATC = FIRE ALARM TERMINAL CABINETzr, THE CABLES SPECIFIED HERE ARE FOR REFERENCE OF REQUIRED ELECTRICAL FBO = FURNISHED BY OTHERS WF = WATER FLOW (f) Lt '' co STORAGE 415 CHARACTERISTICS AS WELL AS CODE REQUIREMENTS. ALTERNATE SUPPLIERS MAY BE FCC = FIRE COMMAND CENTER W = (eg. 1/2W) WATT Y o FAA = FIRE ALARM ANNUNCIATOR W/ - WITH .//�12o VOLT Ac Lt SUBSTITUTED PROVIDING EQUIVALENT CHARACTERISTICS ARE MAINTAINED. ITEMS SUCH AS FTR = FIRE ALARM TRANSPONDER a) W/0 = WITH OUT 4TH FLOOR H CAPACITANCE BETWEEN CONDUCTORS AND WIRE GAUGE CAN BE CRUCIAL TO THE CIRCUIT FSD = FIRE SMOKE DAMPER N m c., N DESIGN OF THIS SYSTEM INSTALLATION. O W CV f. REFERENCE https://www.anixter.com/customer/tycofs FOR SG ANIXTER CABLE DATA E Jo 1 � DEVICE AD7 CESS \ G EGE\ D SEC ENCE OF CPERAT 0 \ -� �, o o � z � Z QNQ o zo Q CONTROL UNIT ANNUNCIATION NOTIFICATION REQUIRED HIRE SAFETY CONTROL SUPPLEMENTARY Y. I ADDRESSABLE CARD (IDNET OR MAPNET)^ / \off NODE DESIGNATOR DE'JICE ADDRESS �o� \o3 vc'D\o� il 1 :PV 1 . �o .�o P� :41:cc Q 4.-',.,\ \, Q P �� yADDRESSABLE DEVICES NUMBERING: `Q� P���' y`'� ' o�aQo ��O�O�\o��' �`POQt�� � S �GP�' •\`' o 0 �� �v�P o. o� c) 4 `moo �P P 6 co P�',`O \' `� �Q -5 5 s 4, .�<-) <z)- .R;\,,c GP C) cJ 4) ��� �. SGP-\o, F,s c� �- <z)\- �o�0�� <z)\- Q. y- ��0 �` � �JO, ����oo� \�Q\ o���Op o� JO p� JO o� JO Q \, Q \41,k0 Q� G P G P G P P Q�' Q, �Q `� �c.F y0 `O 5� 76 5 ( �� ` Z 4009 NAC PANEL CIRCUIT DESIGNATOR op � JJJJJJJ ` J ` (WHEN APPLICABLE) V=VISUAL OR , ` G` G` ' ` �'` co - `' �PPP .• PQPPN- O � $'.<-- /# N' � SL-`c k' ' OPsa w SYSTEM INPUTS A B C D E F G H I J K L M N O P Q R S T U V W X Y Z AA AB AC AD AE AF AG AH REMARKS NODE DESIGNATOR-- r- DEVICE DESIGNATOR 1 SMOKE SENSOR/DETECTOR • • • • • • • • • • I 1 1 :NAC 1 :V2- 1 2 MANUAL PULL STATION • • • • • • • • 20 m 3 DUCT SENSOR/DETECTOR • • • • • 3 N 4 ATRIUM BEAM DETECTOR • • • • • 4 VISUAL, AUDIBLE OR A/V DEVICE - 5 MAIN FLR. ELEV. LOBBY SMOKE DETECTOR • • • • • • • • • • • • 5 co 6 ELEVATOR LOBBY SMOKE DETECTORS (EXC. MAIN FLR.) • • • • • • • • • • 6 I- 7 ELEVATOR MECH. ROOM SMOKE DETECTOR • • • • • • • • • • • 7 045 g g a B 9 _ 9 o 10 WATERFLOW SWITCH _ • • • • • • • 10 0 11 TAMPER SWITCH • 11 12 12 = o 13 FIRE ALARM AC POWER FAILURE • • • • • 13 °' 14 FIRE ALARM SYSTEM LOW BATTERY _ • • 140 4 15 OPEN CIRCUIT • • • • • 15 16 GROUND FAULT • • • • • 16 a. 17 NOTIFICATION APPLIANCE CIRCUIT - CLASS B/STYLE Y: 17 - ,,, 18 WIRE-TO-WIRE SHORT • • 18 0 19 _ 19 a E N 20 20 w Y ti 21 21 D ¢ o 0 22 22 "' < c a) 23 23 co 24 24 O 2525 z26 26 Z 27 -27 DRAWN BY: R. HERMA 28 28 CHECKED BY: M. GERRONE < 29 29 = ISSUE DATE: 8/10/17 30 30 JOB#: 31 31 PROJECT#: 448:601195001 0 ABCDEFGH I JK LMNOPORS TUVWX Y Z AA AB AC AD AE AF AG AH SIMPLEXGRINNELL© 2017 'F° L C , SYSTEM: t C FIRE ALARM SYSTEM O my SHEET: i GENERAL INFORMATION o m c E V m m o d) a m N_ W E II L o W U m • a FA-002 x = N M a E 2 • GENERAL NOTES: 1. ALL CEILINGS ARE ASSUMED TO BE 10' A.F.F., SMOOTH CONSTRUCTION UNLESS NOTED A1 i9 • • OTHERWISE. 2. EXISTING DEVICES SHOWN SHADED FOR REFERENCE ONLY. t E tONCV �CO At nig, c m� r V § E v .0� w .g CiZ eilk al O L. i Q It ii4 � 1:NAC4 BATTERY CALCULATIONS 3g- 1:NAC4 NOTIFICATION APPLIANCE CIRCUIT SCHEDULE u,w Standby Total Alarm Total PLAN CKT PANEL CIRCUIT DESCRIPTION i OF DEVICES CURRENT (A) �w5 4FL HORN STROBES n, 1- oYo Module Description Qty Current Standby Current Alarm 1:NAC4:V1 MAC 1 / 9 0.678 CU o r23� Panel Equipment 1:NAC4:V2 NAC 2 4FL SUITE 400 NOTIFICATION 12 1.007 CO s 4009-9201 4009 IDNET NAC EXTENDER, 120 VAC 1 0.085 0.085 0.185 0.185 1:NAC4:V3 NAC 3 4FL SUITE 450 NOTIFICATION 9 1.21116 1:NAC4:V4 NAC 4 SPARE 0 0.000 Total Panel Stby 0.085 Total Panel Alarm 0.185 Notification Appliance Circuits (From NAC Schedule) 2.896 62 Total Periph Stby 0.000 Total Periph Alarm 2.896 s Total Standby Amps 0.085 Total Alarm Amps 3.081 VOLTAGE DROP CALCULATIONS - 1:NAC4:V1 E I WIRE GAUGE 14 AWG Standby Alarm 2X WIRE RESISTANCE PER FOOT 0.00614 OHMS STARTING VOLTAGE (AT END OF BATTERY DISCHARGE CYCLE) 19.5 VDC Qty Current Current MINIMUM DEVICE VOLTAGE 16 VDC Control Panel Power (Master Power Supply) 0.085 0.185 PERCENTAGE VOLTAGE DROP 3% - Power For External Peripheral Devices 0.000 2.896 DEVICE MODEL CD DISTANCE DEVICE NAC VOLTAGE VOLTAGE AT _ 0.085 <-- Totals --> 3.081 NUMBER NUMBER (FT) CURRENT (A) CURRENT (A) DROP (V) DEVICE (V) Standby Time = 24 Hrs 1.851 Standby Ah 1:NAC4:V1-1 4906-9130 15 50 0.086 0.678 0.21 19.29 Alarm Time = 5 Mins. 0.245 Alarm Ah 1:NAC4:V1-2 4906-9129 30 36 0.116 0.592 0.13 19.16 Battery Supplied 2081-9272 6.2AH 3.390 Total Ah 1:NAC4:V1-3 4906-9104 15 37 0.075 0.476 0.11 19.05 1:NAC4:V1-4 4906-9103 15 39 0.060 0.401 0.10 18.96 s 1:NAC4:V1-5 4906-9103 15 11 0.060 0.341 0.02 18.93 1:NAC4:V1-6 4906-9103 15 18 0.060 0.281 0.03 18.90 - _ 1:NAC4:V1-7 4906-9103 15 12 0.060 0.221 0.02 18.89 E 1:NAC4:V1-8 4906-9130 15 38 0.086 0.161 0.04 18.85 1:NAC4:V1-9 4906-9104 15 29 0.075 0.075 0.01 18.84 1 © 4 5./ C' iz VOLTAGE DROP CALCULATIONS - 1 :NAC4:V2 r 1 WIRE GAUGE 14 AWG a I 2X WIRE RESISTANCE PER FOOT 0.00614 OHMS STARTING VOLTAGE (AT END OF BATTERY DISCHARGE CYCLE) 19.5 VDC rr MINIMUM DEVICE VOLTAGE 16 VDC D / {' r i -- PERCENTAGE VOLTAGE DROP 6% DEVICE MODEL CD DISTANCE DEVICE NAC VOLTAGE VOLTAGE AT 8 j OFFICE OFFICE OFFICE' OFFICE I OFFICE NUMBER NUMBER (FT) CURRENT (A) CURRENT (A) DROP (V) DEVICE (V) E ,// • 1:NAC4:V2-9 / I 416 415 414 413 412 I 1:NAC4:V2-1 4906-9101 15 _ 55 0.060 1.007 0.34 19.16 15 CONFERENCE I I 1:NAC4:V2-2 4906-9101 30 16 0.094 0.947 0.09 19.07 •= 408 1:NAC4:V2-3 4906-9127 30 37 0.116 0.853 0.19 18.87 i L ' V� )/ s �i 1:NAC4:V2-4 4906-9101 75 61 - 0.186 0.737 0.28 18.60 a OFFICE I 15 1:NAC4:V2-5 4906-9127 15 33 0.075 0.551 0.11 18.49 3 / HALL 1:NAC4:V2-6 4906-9101 15 32 0.060 0.476 0.09 18.39 5 417 I V- 1:NAC4:V2-6 \ .., s )}71 1:NAC4:V2-51:NAC4:V2-7 4906-9127 30 12 0.116 0.416 0.03 18.36 0 0 a-1\ / V - \ 1:NAC4:V2-8 4906-9101 15 33 0.060 0.300 0.06 18.30 0 7 11 V I j 1:NAC4:V2-9 4906-9101 15 15 0.060 0.240 0.02 18.28 \ ,\ - i:NAC :V2-10 1:NAC4:V2-10 4906-9101 15 21 0.060 0.180 0.02 18.26 V 15 t:NACa:V2-11 1:NAC4:V2-11 4906-9101 15 16 0.060 0.120 0.01 18.24 OFFICE OFFICE STORAGE CLOSET �( Q 15 I t:NAC4:V2-12 4906-9101 15 29 0.060 0.060 0.07 18.23 418 OPEN 429 410 409 / OFFICE 1 3 I • INTERVIEW/G I / t:NAca:vz-a ER VIEW TESTING II7 I 427 ,�{ 75 �. 1:NAC4:V2-7 t 07 h\ 40 o 11 i:NAC4:V2-6 �.4 30 o-V 'NTE VIEW H V 15 �1 �. V RECEPTION j TE TING/ VOLTAGE DROP CALCULATIONS - 1:NAC4:V3 OFFICE Ait WAITING 4p5 WIRE GAUGE 14 AWG 1 419 I I OFFICE' / j 404 iit:NAC4:V2-12 • 2X WIRE RESISTANCE PER FOOT 0.00614 OHMS e i 428 SKILLS �� 115 STARTING VOLTAGE (AT END OF BAIItKY DISCHARGE CYCLE) 19.5 VDC o LAB ^1, w (t:NAC4: 2) I MINIMUM DEVICE VOLTAGE 16 VDC 402 I CLOSET ' I II 10K PERCENTAGE VOLTAGE DROP 7% 0 © . I -hi I^ _nTh 403 I II _ - DEVICE MODEL CD DISTANCE DEVICE MAC VOLTAGE VOLTAGE AT CI- I NUMBER NUMBER (FT) CURRENT (A) CURRENT (A) DROP (V) DEVICE (V) 1:NAC4:V1-8 ' I ` 1:NAC4:V1-3 I I I 3 1:NAC4:V3-1 4906-9103 30 42 0.094 1.211 0.31 19.19 OPEN 3:0NAC4:V2-3 OFFICE 0_t: 1vtp8 n15 o V O )2±, 1:NAC4:V3-2 4906-9129 75 17 0.221 1.117 0.12 19.07 IIX1 V) o �p y 1:M1-126 5 1:NAC4:V3-3 4906-9103 15 36 0.060 0.896 0.20 18.87 w E wOFFICEO 426 "1 1: 1-127 r /�j `h �- - 1:NAC4:V3-4 4906-9103 15 41 0.060 0.836 0.21 18.66 € 1:NAC4:V3-5 4906-9129 30 18 0.116 0.776 0.09 18.58 .g b /--- j f--" I i \ 1 1:NAC4:V3-6 4906-9103 30 20 0.094 0.660 0.08 18.50 rn IT V o 1:NAC4:V3-7 4906-9103 15 35 0.060 0.566 0.12 18.37 0 - I 1•'��1 ,! I I - 1:NAC4:V3-8 4906-9129 75 21 0.221 0.506 0.07 18.31 - CO c o - I '.�: 1 / II E I 1:NAC4:V3-9 4906-9129 110 61 0.285 0.285 0.11 18.20 , (' 2 1 NAC I ��, "-.-:V1-7 /"l 15 A . 4 I IF OPTIONAL SHIELDS ARE USED FOR IDNet WIRING. 717, !(�+ \�- HALL - I T�f*'°°- oZ !S •15 \ r �''-, FOLLOW THESE PRECAUTIONS. - @ , ER VER 1 15 C � , ,V _ I%�I�'� C 1:NAc4:v1 I N CO co $ 422 / �� CC 1. IF ZDNet WIRING CONTINUES ON TO ANOTHER II OFFICE 424- / @ ( 75� �15 30 DEVICE, TAPE SHIELDS TOGETHER. DO NOT M O Z N = I 421 `� 1:M1 I :NAC4:V1-6 t V O - - TERMINATE SHIELD AT 4009 ZDNet. / / S FROM PREVIOUS ZDNet DEVICES W 1:NAC4:V1- 2 1 OR HOST ZDNet CONTROL PANEL Ncu I I ,^1 V '�' V F 1:NAC4:V2_1 1 11 I \� _ 1:M1-125 _ E I 2. IF IDNet WIRING TERMINATES AT 4009, TAPE M TO ADDITIONAL ZDNet DEVICES O W DA I SHIELD. DO NOT TERMINATE SHIELD AT 4009 ZDNet 0 S J o I 30 115 fi OR RETURN TO HOST ZDNet CONTROL PANEL 1 , N -• - Net CONTROLLER ADDRESS: 1:M1-121 - Z 8 ' / 1:NAC4:V2- I -El ,-,fpr ! 1 f f O Q BREAK I o-v 1:M1-13; i I - r ; 1---.._ h t� Q cu 423 I STORAGE �. I^, r. I (� I `' 1 I = O O Q € `5 1 425 I i `( 1-1 I Q 7t 1 1-�: i � ' --� 1:NAC4:V3 2 N -I "Cr JrI- j ;01/2; iL�l � i:NAC4:V2 i o JAN'TO al ' 1 1:M7-121 Vj AREA OF WORK I I NAG4I STORAG1 1:NAC4:V1 2 I BREAK I ® 41x1 / I o o v •• V LA 410 I II • ' 1 I "--I 1:M1 122 I I r e-' ' cl_¢ i 1 1 t �i 1:M1-124o "' I OFFICE OFFICE ) COPY I V `'J _,- v , J Xt 1:NAC4:V1-1 413 1 412 Iv 411 r 1 �� �}J/ tadt-t2 O2 C IThf ,�, -F L _ € s II 1:NAC4:v3-1 STORAGE' INTERVIEW 8 ® Ill -.e0me 8 s (r �30 X09 rV 407 ^- V 1:NAC4:V3-4 I I_ II' 0 " °.Ioi��!,� E isw2 <m�m Q Q� c • • '-' rc, wt2 "e3 wc. IDNET i ( LV 1�NnC4V3_z %� RECEPTI INTERVIEW15 9 lilI ER VER 1:NAC4:V3-3/ 401 - 402 LI Illooh _ H 408 ,� II _ Z 1 I i i �,4 `� g V l i I e ❑ ❑ ❑❑ eeea O Q B_� 6�Y 6,�Y a cc OPEN 1:NAC4:V3-5 O; ❑ M f - 0 _ I OFFICE I / ry 30 1� STORAGE I Aux PowER OWOW O a o c t 414 b \ o a } ? II P� v� 403 I WSO 0 0 0 - 0 z w 1 I 15 IN MUT 1 w I V.� 1:NAC4:V3-7 i n i \ RET OUT RISME PM O"IT WOR Bi 0 cu i �¢ 1:NAC4:V3-87 A2 mart .0 BATTERY / nn INTERVIEW406I j;�,\ 30 1:NAC4:V3-6 T. RET 1 ID O) �� ® Io e g ``. 8 4009-9201 ZDNet NAC EXTENDER � 00 I\ I- row¢vac we MEP OQ P I 75 _l~ . ® /SST o1m-771 .eco ® . j�/�//////�/�/l/////�////� ow CONFERENCE "' _ w 1 I I I I I I 404 1 "aim- BAPnR WOOS AS-997A 3 II 1 OFFICE �,wuxrss nrsas 1 ` ° S c=i t i 1:NAC4:V3-9 V1--,..N\ . 405 + _ + _ % " S -CONNECT TO 120VAC 60H2 INPUT 3A MAX. o (1:NAC4:V3) 110 B I ` mI j. "°r Inx tOK L- C ! _ _ r- - W II' PART - - - '�/-p���/ L , I 1ERT OF U a �/ - -- - �` - - - - - - - - _' --G-- ` _ I J 1 6.2 Ah BATTERY 6.2 Ah BATTERY -ter / w I M� OF WORK 2081-9272 2081-9272 z - q n ~ ' j/ o o I ,n J Z3 (OD _ 0) PLAN 30 NORTH CONNECT A 12 AWG COPPER GROUND WIRE FROM SAFETY o GROUND IN THE ELECTRICAL DISTRIBUTION PANEL TO - THE 4009 SAFETY GROUND SND. DEVICE P _ACEvE\T PA\ - 4TH FLOJ � � DRAWN BY: R. HERMANT g c-dCHECKED BY: M. �� SCALE: 1�8" = 1'-0" -'_�� SSUE DATE: 8/10/17 O 4ERRONE g 8 16 NAC4 PA\ EL LAYCJT JOB#: (IN FEET) PROJECT#: 448:601195001 8 1.2 LOCATION: 4TH FLOOR, JANITOR'S STORAGE 415 o t NTS SIMPLEXGRINNELL© 2017 € SYSTEM: ` ` FIRE ALARM SYSTEM 8 SHEET: 1 4TH FLOOR DEVICE L z PLACEMENT PLAN, NAC4 LAYOUT& CALCS a E g N . W O m a W 7 Q tit FA-101 - x g e. w a€L DEVICE MOUNTING HEIGHT REFERENCE (PER NFPA 72) END—OF—LINE RESISTOR CODES fb I, VISUAL APPLIANCE MOUNTING HEIGHT CONSIDERATIONS IN SLEEPING ROOMS A/C SUPPLYillfr 0- N 1. MIN DISTANCE IN SLEEPING ROOMS IS 24" (610mm) FROM CEILING TO OR RETURN NOTE: REFER TO PANEL/MODULE AND DEVICE INSTALLATION �� z DIFFUSER THE 4" REQUIREMENT FOR SMOKE DETECTORS HAS INSTRUCTIONS FOR PROPER TERMINATIONS. TOP OF LENS FOR 110CD STROBES WITHIN 16' OF THE PILLOW BEEN REMOVED FROM THE 2010 EDITION OF NFPA 72 Vaian LO"0.0"' o 2. 177CD STROBES, USED IN SLEEPING ROOMS, CAN BE WITHIN THE 24" * USE WITH RETROFIT OR HIGH CURRENT MODULE ,ii (610mm) MINIMUM DISTANCE FROM THE CEILING. THE HIGHER f 4" NOTE: MEASUREMENTS —� \ I 3' (MIN) —.I (102mm) SHOWN ARE TO THE REFERENCE _u- INTENSITY IS TO COMPENSATE FOR A POSSIBLE SMOKE LAYER. I CLOSEST EDGE OF THE MODEL NUMBER OHMS 1ST BAND 2ND BAND 3RD BAND 4TH BAND 5TH BAND WATTS CIRCUIT TYPE FIRE ALARM PANEL/MODULE 1:3I (914mm MIN) CEILING p Waw Y, / / / , / / ///// \\\\\\(///l/off//////////////////�///////////l��/////// // DETECTOR. 4081-9001 733-892 2.2K RED RED RED GOLD N/A 1/2 ANNUNCIATOR (4300) 4004, 4010 (TROUBLE) N N.O. INITIATING 4004*, 4004R, 4005*, 4006, ~ �m FOR CEILING HEIGHTS LESS THAN 86" 2180mm , CEILING MOUNTED / PULL, SMOKE, HEAT, 4100, 4120, 4100U, ZAM'S ■� ��� = mg ( ) NFPA 72 AUDIBLE APPLIANCE SMOKE/HEAT 4 4081-9002 733-893 3.3K ORANGE ORANGE RED GOLD N/A 1 WATERFLOW, TAMPER, ETC. CO_+ -t Dom 2 THE VISUAL LENS MOUNTING HEIGHT SHALL BE 6" MIN (152.4mm MIN) DETECTOR (102mm) 12" (MAX) 24 PT. I/O SWITCH SUPV. 4605-7401, 4100 SERIES RI < NOM WITHIN 6" (150mm) OF THE CEILING. AUDIBLE ONLY BELOW FINISHED CEILING a o 0' (305mm MAX) CURRENT LIMITED N.O. INITIATING 4090 9001 IDNET IAM EOLR HEAT DETECTORS 4081-9003 733-896 4.7K YELLOW VIOLET RED GOLD N/A 1/2 (EOLR) 1 �(c) ® J + 0 90" MIN (2286mm MIN) ACCEPTED HERE NEVER HERE / / NOTIFICATION (DACT) 2080-9024 O C o ABOVE FINISHED FLOOR I N.O. INITIATING 4004, 4005, m o c�� \ T ��� (OTHER MOUNTING HEIGHTS SHALL BE 4081-9004 733-886 6.8K BLUE GREY RED GOLD N/A 1/2 PULL, SMOKE, HEAT, 4090-9001 IDNET IAMup PERMITTED BY THE AHJ PROVIDING IT WATERFLOW, TAMPER, ETC. 2190-9173 MAPNETII 2 PT I/O AUDIBLE/VISUAL MEETS THE SOUND LEVEL OUTPUT REQUIRED.) 4-20MA ZAM (TROUBLE) & VISUAL ONLY WALL MOUNTED CURRENT LIMITED N.O. INITIATING 3 APPLIANCES TO EXIT DOOR SMOKE/HEAT 4081-9005 733-984 1.8K BROWN GREY RED GOLD N/A 1/2 (IN LINE) 4090-9001 IDNET IAM - - 5' (MAX.) DETECTOR s (1524mm) 4081-9006 733-890 560 SZ GREEN BLUE BROWN GOLD N/A 1 N.C. INITIATING (EOLR) 4005*, 4090-9001 IDNET IAM SYNCHRONIZE MORE THAN DOOR 4100, 4100U TWO APPLIANCES IN ANY LESS 3" 4081-9007 733-891 1.2K BROWN RED RED GOLD N/A 1 N.C. INITIATING (EOLR) 4005 a FIELDOFOF VIEW. (76mm) 4004, 4005, 4006, 4008, 4081-9008 733-894 10K BROWN BLACK ORANGE GOLD N/A 1/2 NOTIFICATION 4009, 4010, 4100, 4100U 96" MAX (NFPA, ADA) 5„ SIDE WALL 4081-9009 733-912 200 RED BLACK BLACK GOLD N/A 1 TO MR-101 RELAY COIL 4005 8 POINT I/O (2440mm MAX) (127mm) N.C. INITIATING (ACROSS CONTACTS) 4005*, 4090-9001 IDNET IAM ABOVE FINISHED FLOOR24 PT. I/O (ACROSS CONTACTS) 4605-7401, 4100 SERIES REF. 80" MIN (IBC) MANUAL 4081-9010 733-973 1K BROWN BLACK RED GOLD N/A 1 s TO TOP OF LENSCURRENT LIMITED N.O. INITIATING 5 (2032mm MIN) PULL 1� (IN SERIES WITH CONTACT) 4090-9001 IDNET IAM is REF. 96" MAX (IBC) STATION 4081-9011 733-974 100 SZ BROWN BLACK BROWN GOLD N/A 1/2 ANNUNCIATOR (N2) 4006, 4008, 4010 E 80" MIN (ADA) (2032mm MIN) FIRE / / 5 (2440mm MAX) 80" MIN (NFPA) (2032mm MIN) PHONE MAGNETIC 4081-9012 733-985 22K RED RED ORANGE GOLD N/A 1/2 SPEAKER CIRCUIT 4003 a ABOVE FINISHED FLOOR TO BOTTOM OF LENS JACK ® DOOR /� 4081-9013 734-086 4.99K YELLOW WHITE WHITE BROWN BROWN 1/2 _ HOLDER / N.C. INITIATING ° � FINISHED 4081-9014 734-092 2.4K RED YELLOW RED GOLD N/A 1/2 (SECURITY MONITORING EOLR) 4090-9001 IDNET AM a ® WALL CURRENT LIMITED N.O. INITIATING N NOTE: REFER TO THE PROPER DEVICE 48" MAX (ADA) (1219mm) 4081-9015 734-093 1.5K BROWN GREEN RED GOLD N/A 1/2 (SECURITY MONITORING EOLR) 4090-9001 IDNET IAM ; INSTALLATION INSTRUCTIONS FOR BACKBOX MOUNTING HEIGHT. 48" MAX (NFPA, ADA) (1219mm MAX) 4081-9016 734-149 150K BROWN GREEN YELLOW GOLD N/A 1/2 H FINISHED 42" MIN (NFPA) (1067mm MIN) 4081-9017 734-171 3.9K ORANGE WHITE RED GOLD N/A 1 E FLOOR MEASUREMENTS SHOWN ARE 4081-9018 734-168 10K BROWN BLACK ORANGE GOLD N/A 1 70VRMS CONSTANT SUPV. NACS 4100-1260 1 \ TO TOP OF PULL HANDLE 378-090 8.2K GRAY RED RED GOLD N/A 1/2 SECURITY MONITORING (EOLR) 4100, 4100U s 378-046 5.6K GREEN BLUE RED GOLD N/A 1/2 N.O. SECURITY MON. (SERIES) 4100, 4100U ts 378 069 12K BROWN RED ORANGE GOLD N/A 1/2 N.C. SECURITY MON. (SHUNT) 4100, 4100U TrueAlerrNON—ADDRESSABLE MULTI—CANDELA VISIBLE NOTIFICATION APPLIANCE TrueAlertNON—ADDRESSABLE MULTI—CANDELA AUDIBLE/VISIBLE NOTIFICATION APPLIANCE 8 PRODUCT INFORMATION WHEN SURFACE MOUNTING USEPRODUCT INFORMATION (WALL MOUNT) RED SKIRT NO. 4905-9937 OR (ELECTRONIC HORN W/STROBE) FEATURES: WHITE SKIRT NO. 4905-9940 FEATURES: WHEN SURFACE MOUNTING USE •UL LISTED TO STANDARD 1971 4905-9931 ADAPTER PLATE a 2975-9145 BOX • CLASS B (Sa' SQUARE x 1-1/2" DEEP BOX TYLE Y) OPERATION REQUIRES CONNECTION RED SKIRT NO. 4905-9937 (RED)\ 4" SQUARE x 1 1/2" DEEP BOX g •ADA COMPATIBLE 0 TO A COMPATIBLE SMARTSYNC NAC OR TO -- - WHITE SKIRT NO. 4905-9940 (WHITE) SYNCHRONIZATION TUSH RATE MODE FOR USE WITH: ai �1=in o SMARTSYNC CONTROL MODULE (SCM) 4905-9938 IMPORTANT! 0 � • CLASS A (STYLE Z) OPERATION WHEN CONNECTED TO THE WALL MOUNT INSTALLATION0 s •SEPARATE STROBE SYNCHRONIZATION MODULES THAT ARE AVAILABLE ° _ FOR CLASS B OR CLASS A OPERATION , ����-� 4905-9961 OPTIONAL WIRE _ 4905-9938 SCM OR 4100U SERIES FIRE ALARM HEIGHT REFERENCE • O 3 I/7�1�I�I ��II' GUARD (SHOWN HERE FOR , CONTROL PANEL NAC'S 0 c.0 •SEPARATE SMARTSYNC CONTROL MODULES (SCMs) THAT PROVIDE I REFERENCE ONLY, CAN BE ° ELECTRICAL BOTTOM OF IFNs %���������r�l��; O BOX OUNNE N EITHER EVEN WITFI 1 CLASS B OR CLASS A OUTPUT FROM CONVENTIONAL NAC INPUTS USED ON OTHER MOUNTING SPECIFICATIONS: I/II��I��I■Ii OPTIONS) %bp �� ° oR sucHaY ABOVE ° o' BOTTOM OF SPECIFICATIONS: ( �= • HOUSING DIMENSIONS (INCLUDING LENS) : 5 1/8'1 X 5' W X 2 3/4"D COMpANe E BOx6 Nib, �� o•HOUSING DIMENSIONS: 5-1/8" H X 5' W X 2-3/4' D (130mm X 127mm X 70mm) IIII / OW • ° • HUMIDITY 10% TO 93% NON-CONDENSINGRE RANGE: 37 F TO 127 F (0' TO T C)100' F 38' C) '_`•TEMPERATURE RANGE: 32"F TO 122'F (0 TO 50'C) re._ _ 4I� /� �p.� ( /���� o - •HUMIDITY RANGE: 10% TO 93% NON-CONDENSING AT 100'F (38'C) I I`_ - R' �II' ` 0_, .. • TERMINAL BLOCKS FOR 18 AWG TO 12 AWG; TWO WIRES PER / `► ��•TERMINAL BLOCKS FOR 18AWG TO 12AWG; TWO WIRES PER �_� 'tat TERMINAL FOR IN/OUT WIRING. MMn NFPA 72 REQUIRES THAT \` gr. �' THE ENTIRE LENS BE NOT TERMINAL FOR IN/OUT WIRING. 0 Q _ 0 80' . ` ��, o ALTERNATE HACK BOXESLESS TDRE 80•AND NOT ,�I;WIRING: ■ .-.-.-. GRFATTR THAN 9s ABOVE/ / 1. 2 GANG 1-1/2" DEEP BOX MN. �'. Qc. 2. SINGLE GANG 1-1/2' DEEP BOX =1=1==1.11,. 1 THE FINISHED FLOOR. \� v ALTERNATE BACK BOXES 1. NOTIFICATION APPLIANCES ARE RATED PER INDIVIDUAL NAMEPLATE LABEL STANDARD ELECTRICALLE BOX MOUNTING I� �� j ���; / 1. 2 GANG 1 1/2' DEEP BOX 2. MAINTAIN CORRECT POLARITY ON TERMINAL CONNECTIONS. DO NOT LOOP Aiiimi 4905-9961 OPTIONAL WIRE 1/111111.1 1111111 I z �� 'I 2. SINGLE GANG 1 1/2' DEEP BOX WIRES UNDER TERMINALS. GUARD (SHOWN HERE FOR I� ,�3. ALL NAC WIRING CONNECTIONS ARE SUPERVISED AND POWER-UMITED. RET-ERENCE ONLY, CAN BE I �,1, / / r4. SEE INSTALLATION INSTRUCTIONS (579-548) FOR ADDITIONAL INFORMATION. USED ON OTHER MOUNTING / 2 STROBE: SURFACE MOUNTING CSEMI-FLUSH MOUNTINGOPTIONS) 'II�� � ` SEMI-FLUSH MOUNTING CD• RATED VOLTAGE RANGE: UL LISTED: 16 VDC TO 33 VDC PER UL 1971 / ULC USTED: 20 VDC TO 30 VDC PER ULC S526-M878 R'� 2975-9145 BOX - v • FLASH RATE: 1Hz SURFACE MOUNT ADAPTER SKIRT HORN I� �I ' J/ �' o •SYNCHRONIZED MODE NAC LOADING: MAXIMUM OF 35 SYNCHRONIZED STROBES PER NAC CIRCUIT. 1 5/8" (41mm) DEEP. - SOUND OUTPUT CHARACTERISTICS: 2400 TO 3700 Hz SWEEP, r •N. CONDUIT CUTOUTS ARE PROVIDED4905-9931 ADAPTER PLATE •CURRENT DRAWS REFLECT STROBE FLASHING ON ALL FOUR SIDES. TO ADDITIONAL NOTIFICATION MODULATED AT 120 Hz RATE ISI "d u APPLIANCE DEVICE OR RETURN ( ) TO ADDITIONAL NOTIFICATION a'a' HOUSING LEIMINGSTROBE RMS CURRENT 0 HORN SOUND OUTPUT RATINGS ® 10 FT. 3m E MODEL NUMBER COLOR COLOR RATING 16 VDC 18 VDC 24 VDC TO FACP FOR STYLE Z APPLICATION _ __ LL IF LAST DEVICE ON CIRCUIT INA - __ - APPLIANCE DEVICE OR RETURN 4906-9101 RED WHITE 15cd 60 mA 53 mA 40 mAVOLTAGE 16 VDC 24 VDC 33 VDC TO FACP FOR STYLE Z APPLICATION —2 STYLE Y APPLICATION PLACE A E. 30cd 94 mA 84 mA 63 mA + SOUND TYPE ' STEADY CODED STEADY CODED STEADY CODED1 IF LAST DEVICE ON CIRCUIT INA D in 75cd 186 mA 165 mA 124 mA TERMINALS 3 & 4 ARE NOT USED 10K 1/2W END-OF UNE RESISTOR Q w l + STYLE Y APPLICATION PLACE A 110cd 252 mA 224 mA 168 mA REVERBERATE CHAMBER TERMINALS 3 & 4 ARE NOT USED / 86 dBA 82 dBA 88 dBA 84 dBA 90 dBA 86 dBA 1OK 1 2W END-OF UNE RESISTORW CC Ei 4906-9103 I WHITE I RED 15cd 60 mA 53 mA 40 mA I UL 464 TEST s 30cd 94 mA 84 mA 63 mA , , i 0 75cd 186 mA 165 mA 124 mA I _ �� I ( I _ Irk.in*" _ ANECHOIC CHAMBER 92 dBA 91 dBA 94 dBA 95 d8A 96 dBA 96 dBA I I I I v) o SII }'SKI 0 ill " r �� • v 110cd 252 mA 224 mA 168 mA I I t9! I I I `l I I C7/ I r psi - /�/ a 0 �,j I O (,) I CODED VALUES ARE TYPICAL Of THE OUTPUT MEASURED WITH A TEMPORAL I I— O Llll k' I I I O LIII K' I i m s CODED ORA MARCH TIME CODED PULSE AND WITH A SOUND LEVEL MEIER co FROM A COMPATIBLE SIMPLEX I ■ I I 0' I I 0 • �,) O • O� M IMPORTANT! l+ r 13 ° V ® READING ON A 'FAST SPITING. UNDER THE SAME TEST COND TIONS, CODED O I I O O , I ` v w SMARTSYNC NAC OR FROM + 0 HORN OUTPUT "PEAK" SOUND LEVEL READINGS ARE TYPICALLY 4 dBA HIGHER. ■ �j W CV = WALL MOUNT INSTALLATION SMARTSYNC CONTROL I 1111,21 (� I I FROM A COMPATIBLE + I O r. �- _ '� 0 l� �� l l IIII� 0 UL_ �l! 1 u ° 0 I l �I Illi° I Z o MODULE (SCM) 4905-9938 r m ' '■ m ' SIMPLEX SMARTSYNC CD _ HEIGHT REFERENCE OR SIMPLEX 4905-9914 STROBE NAC OR FROM 1,1010® _ ,. -0p J it c., I I I I SMARTSYNC CONTROL . a — e ELECTRICAL BOTTOM OF LENS OR 9922 SYNC CUBE - RATED VOLTAGE RANGE: UL REGULATED 24VDC PER UL 1971 UBOX oLJR1NE IS EITHER EVEN wmT ' ' ' ULC: 2OVDC TO 3OVDC PER ULC 5526-M878 MODULE (SCM) 4905-9938 I >• I I I J CV = OR SUGHILY ABOVE ' - FLASH RATE: 1Hz ' ' ' 0 H BOTTOM OF I . 111 I I I. 111 - SYNCHRONIZED MODE NAC LOADING: MAXIMUM OF 35 SYNCHRONIZED STROBES PER NAC CIRCUIT. I I. II) I I I. N I J . 0 € 0 COMPATIBLE BOXES CURRENT DRAWS REFLECT STROBE FLASHING AND HORN ON. 7 = O O fr `1"---!----____r—,---- HOUSING LETTERING STROBE RMS CURRENT CO J.,9H,ht I II Z U N QI� O Q �et II I� 0• Q �I MODEL NUMBER COLOR COLOR RATING 16 VDC 18 VDC 24 VDC Z N omo NFPA 72 REQUIRES THAT 75 30cd 116 mA 103 mA 77 mA ar `\ it—IJ ` I_I / MI 10 4906-9127 RLD WHITE 15cd 75 mA 67 mA 50 mA -I O Q it l O J J �} ___I On. THE ENTIRE 80' BE NOT 75cd 221 mA _ 196 mA 147 mA -- I I 80' LESS THAN 80'MD NOT INTENSITY SELECTION 15 110cd 285 mA 253 mA 190 mA - ' _o A MIN. GREATER THAN 96" ABOVE PLUG, ACCESSIBLE ONLY 'MI 4906-9129 WHITE RED - 15cd 75 mA 67 mA 50 mA INTENSITY SELECTION '115__ E. F=- THE FINISHED FLOOR. FROM REAR OF HOUSING; o a I 75cd 221 mA - 196 mA 147 mA - FROM REAR OF HOUSING1.1 ,•1 FACTORY BELTING IS 15cd 110 d 285 mA 253 mA 190 mA PLUG, ACCESSIBLE ONLY ®_ wSTROBE INTENSffY FACTORY SETTING IS 15cd TR EL VIEWING SLOT STROBE INTENSITY - 5. VIEWING SLOT 1€ 8 0 s c2 ZrR I- z 1Q c W I K a CO Lil E • 0) rn I- z m p g 2 co o € aY Ut C U 0 W CO Q U O ° M7 p '0 J NW Y N- N Q 'S O co N 5 a) CO g o w z DRAWN BY: R. HERMANT s E CHECKED BY: M. GERRONE I- ISSUE DATE: 8/10/17 g JOB#: i £ PROJECT#: 448:601195001 5 SIMPLEXGRINNELL© 2017 € g SYSTEM: FIRE ALARM SYSTEM a SHEET: WRING TYPICALS c E N m N w E W j O = N m V F.U m x FA-701 E 1 O ced