Loading...
PFI2018-00156 CITY OF TIGARD PUBLIC FACILITIES IMPROVEMENT PERMIT COMMUNITY DEVELOPMENT Permit#: PF12018-00156 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421 Date Issued: 06/26/2018 Parcel: SEG3908 Jurisdiction: Tigard Site address: Subdivision: Lot: Project: PGE Project Description: Trench for service to River Terrace East Owner: FEES Description Date Amount PHONE: Contractor: PHONE: FAX: Applicant: AMY SWEANY 10800 SW AVERY ST TUALATIN, OR 97062 PHONE: 503-612-2935 Total $0.00 Please sign below to indicate acceptance of conditions and return a copy with the proposed work schedule along with names and contact information of responsible parties before beginning work. Permittee/Applicant Signature: See application Issued By: �—�— - Special Conditions(See Attached) Note:THIS PERMIT DOES NOT COVER WORK ON PRIVATE PROPERTY Conditions for PF12018-00166 Type: Condition Name: Status: Severity: PFI_Utilities 01 -WORK SITE REQUIREMENTS Applied Notice Applicant must comply with all applicable provisions of federal and state law,the Tigard Municipal Code, and the terms of any agreement with the City of Tigard regarding work to be done pursuant to this permit. PFI_Utilities 02-WORK SITE AREA Applied Notice The work area and approach roads shall be maintained in a clean condition, free from obstructions and hazards. The spreading of mud or debris or storage of materials or equipment of any kind upon any public roadway is strictly prohibited and violation shall be cause for immediate cancellation of the permit. The City may at any time order immediate clean-up and suspension of work to accomplish clean-up. PFI_Utilities 03-WORK SITE EROSION CONTROL Applied Notice Prior to starting work,effective and approved erosion control devices must be installed and maintained meeting the Clean Water Services and DEQ requirements. The City may at any time order corrective action and suspension of work to accomplish effective erosion control. PFI_Utilities 04-WORK SITE REPAIRS Applied Notice Disturbed landscaped areas shall be restored or replaced. Existing signs, pavement markings, mailboxes, etc. shall be reinstalled or replaced,with like kind of material. Obtain City approval of restoration work. PFI_Utilities 05-TRAFFIC CONTROL SPECIFICATIONS Applied Notice Applicant shall provide traffic control according to the current edition of the"Manual on Uniform Traffic Control Devices [MUTCD]for Streets and Highways", U.S. Dept. of Transportation, FHWA, current edition,American Traffic Safety Services Association[ATSSA], and Oregon Temporary Traffic Control Handbook[OTTCH]. PFI_Utilities 06-TRAFFIC CONTROL PLAN Applied Notice Submit a job specific traffic control plan. A copy of the approved traffic control plan shall be readily available at the work area. Traffic control devices, flag persons, etc., shall be in place prior to initiation of construction work and shall be effectively maintained. PFI_Utilities 07-TRAFFIC CONTROL ROAD CLOSURE Applied Notice Public roadway shall not be closed to traffic, at any time,without obtaining written approval from the City Engineer. The applicant is responsible to provide 48 hour advance notice of traffic flow disruptions to affected businesses, residents and area wide Emergency Services: 503-629-0111 (Tigard Police Dept., Tualatin Fire&Rescue)and to 503-962-8140(Tri-Met) and 503-431-2345(Tigard School District)and other service providers impacted by such closure. PFI_Utilities 08-TRAFFIC CONTROL PROPERTY ACCESS Applied Notice Access to existing properties shall be maintained at all times, including normal delivery service and mail service. Obtain City approval of any access closures. PFI_Utilities 09-TRAFFIC CONTROL WORK HOURS Applied Notice Work is permitted in daylight between the hours of 7:00 a.m.to 7:00 p.m. Mon-Fri unless otherwise authorized by the City. PFI_Utilities 10-TRAFFIC CONTROL LIMITED WORK HOURS Applied Notice Hours of construction work on collector and arterial roads will be limited to 9:00 a.m.to 3:00 p.m. unless authorized by the City Engineer. Work will not be permitted on collector and arterial roads between 3:00 p.m.to 9:00 a.m. unless authorized by the City Engineer. PFI_Utilities 11 -TRAFFIC CONTROL MODIFICATION Applied Notice The City reserves the right to add to or modify traffic control requirements as necessary to effectively control traffic and to assure public safety. PFI_Utilities 12-UTILITY NOTIFICATION Applied Notice Oregon law requires following the rules adopted by the Oregon Utility Notification Center. Said rules are set forth in OAR 952-001-0100 through OAR 952-001-0080. Copies of said rules may be obtained from the Center by calling 503-246-1987. If you have any question about the rules, contact the Center. NOTE: Damage to utilities shall be corrected at the permit holder's expense. PFI_Utilities 13-UTILITY LOCATION CONFLICT Applied Notice Applicant must verify all existing utilities for both vertical elevation and horizontal location prior to start of work(pothole before digging if necessary). Should conflicts arise and redesign or relocation of facilities be necessary, it shall be done at the applicant's expense. Changes must be approved by the City in advance of work.Applicant shall coordinate the work with affected utility agencies. PFI_Utilities 14-TEMPORARY PATCH Applied Notice A temporary hard-surface patch shall be placed on trenches within roadways at the end of each work shift. Obtain advance approval of patching method. No trench shall be left at any time in an un-safe condition. Applicant is responsible for and is liable for hazards or damage resulting from the prosecution of the work. PFI_Utilities 15-REPAIR OF EXISTING FACILITIES Applied Notice Work under this permit shall include repair of existing facilities(roads, ditches, etc.)as may be necessary, as determined by the Inspector, to overcome deterioration or damage which occurred in conjunction with the work authorized by the permit. Corrective work shall be done at the applicant's expense. PFI_Utilities 16-PRECONSTRUCTION MEETING Applied Notice Before initiating any construction activity,the applicant shall coordinate with the City's inspector, <Insert Name>at<Insert Phone#>,to establish a preconstruction meeting. PFI_Utilities 17-NOTICE TO COMMENCE WORK Applied Notice The applicant shall notify the City's Inspector twenty-four(24)hours prior to commencing work, prior to any staged inspection, and after completing work covered by the permit. PFI_Utilities 18-PERMIT/PLAN ON SITE Applied Notice A copy of the permit including a Certificate of Insurance, and all attachments, and a copy of the approved construction plan and all amendments shall be readily available at the work area. All work shall conform to the permit terms, conditions and provisions and to the City approved permit plans, and approved plan amendments and to the City's standards and specifications and to these General Conditions. Changes to any of these must be approved by the City, in advance of work performance. PFI_Utilities 19-MONUMENT PROTECTION Applied Notice Existing monuments, property corners, and survey markers shall be protected. Replacement shall be at the permit holder's expense. PFI_Utilities 20-EMERGENCY CONTACTS Applied Notice Provide to the City inspector, in writing,the names and 24 hour emergency telephone number of two(2)persons who have authority to resolve problems,take corrective action and, in general,will be responsible in case of any emergency. The applicant shall notify the City Inspector, in writing, of any/all assignment changes. PFI—Utilities 21 -OTHER Applied Notice RDECENED City- of Tigard JUN 10 2018 PUBLIC WORKS —ENGINEERING �` e tYp CIN OF TIGARD' PubhC Faces MIrovement I'' I ff���R'NG TYPE OF WORD DESCRIPTION OF WORD(in the right-of-way) [V TYPE 1—Franchise Utilits,Work Check one: d Utilities ❑ Sidewalk/driveway approach ❑ Street improvements performed by NWN, PGE Detailed description: Trench for service to new 38 lot and/or utility agency. (River Terrace East) ❑ TYPE 2—Sidewalk/Driveway/Sewer PGE Job M2279741 Work performed for the purpose of: • Sidewalk installation or repair. • Driveway approach installation Property address/location(s): S of SW Scholls F rp Rd & SW 175th Ave and/or repair Job fte rs Rd • Sanitary sewer lateral installation "._6z ._6 C O I�j j' and/or main line tap Portland General Electric Submitted b Am Swean ❑ TYPE 3—Full scale Development Applicant: I y y y� Work performed with Land use Address: 10800 SW Avery Street approval which includes any of City/state: Tualatin, OR Zip: 970062 the following: Phone: 503-612-2935 Email: preregcoord@pgn.com • Subdivisions or Partitions Contact name: Dumitru Ilioi Phone: 503-672-5477 • Street widening • Mainline installation for Sanitary Contractor: Northwest Earthmovers Inc. sewer, Storm sewer, Tigard water and/or Tigard Water Service Area CCB#: 62761 Expiration: 11/30/18 Address: 13600 SW Galbreath Dr SUBMIT COMPLETED APPLICATION TO: City/state: Sherwood, OR Zip: 97140 City of Tigard 503-625-3100 Planning/Engineering Phone: Email: 13125 SW Hall Blvd. Contact name: Mike Madison Phone: 503-625-3100 Tigard,OR 97223 Applications for"minor work in right-of-way" En ineer: Pacific Community Design only may be emailed to: g rowpermitsna.tigard-or.gov Address: FOR ONLY City/state: Zip: Phone: 503-941-9484 Email: Craig@pacific-community.com Case No.: °i��� Contact name: Craig Larson Application submittal fee(007%of, Engineer's Estimate) $ r - Estimated value of work is required(if over$5,000):$ 68,936.23 Additional.fees: $ (within the public right-of-way) Application,accepted: By: ' A. Date . Is work related to a LAND-USE DECISIONEl N� No / If so, please specify (MLP,SDR,SUB, etc.) case #: Application reviewed: / f By�� Date: Is work related to a BUILDING PERMIT? ❑ Yes No Applicant notified: If so,please specify(BUILDING PERMIT)case#: By: Date: I:\ENG\PermitApplications\pfi—application Rev:10/16/2017 City ofTigard. 13125 SW Hall Blvd. Tigard,Oregon 97223 -,vwwtigard-or.gov 503-718-2421 • Page 1 of4 APPLICANTS NOTE: Person specified as "Applicant"shall be designated "Permittee"and shall provide financial assurance for work,if required by the city pursuant to TMC 15.041.140. * With the exception of a utility operating pursuant to a valid franchise with the City of Tigard,when the owner and the applicant are different people,the applicant must be the purchaser of record or a lessee in possession with written authorization from the owner or an agent of the owner. The owner(s)must sign this application in the space provided or submit a written authorization with this application. Franchised Utilities are not required to obtain the owner's signature on the application BY SIGNING BELOW,THE APPLICAN'T'(S) SHALL CERTIFY THAT: • The above request does not violate anv recorded deed restrictions that may be attached to or imposed upon the subject ro er . • If the application is granted,the applicant will exercise the rights granted in accordance with the terms and subject to all the conditions and limitations of the approval • All of the above statements and the statements in any plot plan,attachments,and exhibits transmitted herewith,are true;and the applicants so acknowledge that any permit issued,based on this application,may be revoked if it is found that any such statements are false. • The applicant has read the entire contents of the application,including the policies and criteria,and understands the requirements for approving or denying the application. Steve Hursh 6/18/2018 Applicant/Authorized Agent's signature Print name Date SIGNA'T'URES of each owner of the subject property, if required. Owner's signature Print name Date Owner's signature Print name Date Owner's signature Print name Date PUBLIC FACILITY IMPROVEMENT PERMIT City ofTigard 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.tigard-or.gov 503-718-2421 Page 2 of4 DEVELOPMENT ENGINEERING FEES . STAFF USE ONLY Public Facility Improvement(PFI)Permit: D,ETAILED SUBMITTAL .:' REQUIREMENTS® • APPLICATION FEE Part 1: Required submittal fee$300.00 (minimum) FRANCHISE UTILITY AND SIDEWALK/ DRIVEWAY AND UTILITY PERMIT FEE CONNECTIONS,ETC. Part 2: All non-water system improvements (work in the right of way) Engineer's estimate X 5% (less$300.00 minimum submittal fee) Sketch Engineer's estimate X 2%Plan Review (including information below) ❑ Dimensions WATER SYSTEM FEE n Street Name Part 3: All public water system improvements ❑ Site Address Engineer's estimate X 12% FULL SCALE DEVELOPMENT PFI Permit Fee Exemptions: (Subdivisions/Partitions and Street Improvements) There will be no permit fee charged,or assurance required ; for the following types of work: Design Plans • Sidewalk repair (less than 20 lineal feet) (6 sets,24x36 or,2.204) • Relocate or replace mailbox ❑ Cover-Site,-Vicinity,Abbreviation,Legend • Ditch cleaning that does not involve regrading. n General Notes (City;Water,_Sewer;etc.) • Weep hole repair 0 Street(Plan,Profile) • Curb repair or replacement(less than 20 lineal feet) ❑,. Water'Storm and-Sanitary.(Plan Profile), • Lawn sprinkler system installation or repair Water Quality.Facilities • Street tree pruning or planting . Grading • Planter strip landscape maintenance ❑ Landscaping/Tree Plan . • Test wells ❑ Com posite Utility Plan(Electrical,Phone,Gas, Storm,Sanitary,Water,Signage,Street Lights,etc) ❑ Details. Note: A cash/bond assurance may be ❑ Traffic Sight Distance required per TRIC 15.04.140. El Signing.and Striping (customer deposit) ❑ Street Light Plan and Photometric ❑ Engineers seal/signature Sheet label(project land use name,revision and plan log block,dates and sheet numbers) Additional Submittals (per Land Use conditions) El Traffic Report ❑ Storm water Drainage Calculations El Geotechnical Report ❑ Preliminary Access Report(Sight Distance) Proposed.Plat Pathway Design(if applicable) Water Department Approval ❑ Engineer's Construction Estimate. PUBLIC FACILITY IMPROVEMENT PERMIT City ofTigard 13125 SW Hall Blvd. • Tigard,Oregon 97223 • wwwtigard-or.gov 503-718-2421 Page 3 of4 SAMPLE SKETCH: Edge.of P avemerit Ditch — Streetligh7t ®® m ■4,.�® .® . .i�i Rein Dmin ® A 1[1I)0S i ewe 1�I11 " I �;�1u: t �, I � ! :Existing House. I Existing _ 1- a W 1 Driveway _ 1. mf ` l. CU i o' lye 1. tl �I i d r � �E�isting�Shop C e Porr,rerpole o. rt ino e ° Fire Hydrant(FH) I I � � Scale: 1"=30' ° I � I � I I i I i � ° a MINIMUM SKETCH REQUIREMEN'T'S (Put"N/A"if Not Applicable): North arrow Property lines &dimension Slope of property Street &street name(s) Existing building, structures Utility &street light poles Proposed work Existing curb or edge Trees Existing S/W or of pavement Existing utility locations D/W apron (sewer,water,storm) PUBLIC FACILITY IMPROVEMENT PERMIT City ofTigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.tlgard-or.gov • 503-718-2421 • Page 4 of4 O � v>::�. o CD Single Flagger Operation CD for Low Volumes P� I (Optional) p Q W o I (ADT¢400) �" ro sroP A= o o o �' I � I BE 0 �: I ' I PREPAREMe D ONE LANE a I _ AD T n I•a Is s kc Is I TO STOP AD AHEAD 4= I 1�b —--i 4— �' I ► — ® — — I • '40ROAD WORK 00 to 0 0 ?H '° I K c K e j e 4 A a I AHEAD s 4 l✓ N I PMUFCtbnvewq w/ M � 1111 Sea Ctw,pt.r o N N V CJ1'[7SCi ^' SWD qq CD TO UM 000`bncn , S If A B roams L-------------------------I 1 mile t�� _ fm max. -I • • � • � =mss`_ B B Tt Buffer Protection Vehicle • w/TMA(both Optional) ROAD WORK See Chapter 4 AHEAD BE ONE LANE PREPARED n R°ADTo sroP Two Flagger Operation AHEAD v ccno (Optional} A; Co Page 84 2011 Edition Saflaart'y`La�e Cosa��eua �laggog ,. 18®agra' 3�0. Diagram 320 covers total closure of one lane of a two-lane,two-way roadway. See the detail inset for the layout if using a single flagger to control both directions of traffic on low volume roads(less than 400 ADT)with good sight distance as discussed below. 1. Use truck-mounted flashing warning lights on work and protection vehicles_ See Section 4.3—Lights and Lighted Signs for exceptions_ 2. For added visibility, a truck-mounted arrow board or PCMS in caution mode may be used. 3. Flaggers at each approach are required if any of the following conditions exist: a. Night Operations. b. Work space is over 200 feet in length. c. Sight distance is less than 750 feet from each approach through the lane closure. d. Traffic volumes are greater than 400 ADT. 4. The length between the Flagger Ahead signs shall not exceed one mile. Use Diagram 340—Lane Closure with Pilot Car if exceeding one mile. 5. Cones should be used to outline the work space when curves or other roadway alignments prevent clear direction for the motorists to pass the work space safely. 6. Cones along the work space are recommended when posted speeds are 45 mph or greater,when working under heavy traffic or when travel lanes are narrower than 11 feet. 7. Extended queue signing(see Diagram 5-4)should be used when traffic queues extend beyond the initial advance warning sign. 8. When flagging near an intersection,the"Flagger Ahead"(CW23-2) sign should be visible to traffic entering from any side road. Additional advance warning and Flagger Ahead symbol signs may be placed on the side road(s). 9. Sign set-up and flagger placement shown may be used for intermittent full road closures of 20 minutes or less. 10. The"ONE LANE ROAD AHEAD"(W20-4)sign is optional and should be considered on high volume or high speed roads, or when extended queues are expected. Chapter 5 December 2011 Mountainsideo v v High School Y ; SW '010 Fetty Rd SW Scho',ls«stY Rd SAFETY JOB SITE 2 TIGAIRD SW Friendly Ln SW Friendly Ln , e ; JOB SITE I SHEi2WOOD n g , Southwest Forest Hollow Street 0 • ra 0 Our Country Gardens ; i WR CHECKLIST YES COMMENT HOLEDIGGER BOOM A BACKHOE X PGE TRENCH LOCATES STAKING FLAGGING X TREE TRIM LANDSCAPE EASEMENT A PERMITS X CITY OF TIGARD,SHERWOOD TRAFFIC PLANxi CUTSHEET UG CIR. VER. TRANS SHUTDOWN CUST SHUTDOWN DOOR HANGER CONTACT COMPANY PHONE CELL DATE TIME PGF CONSTRUCTION DRAWING Mu M2279741 DESCRIPTION UG SVC TO 38-LOT SUBDIVISION TITLE POLYGON NORTHWEST/RIVER TERRACE EAST PHAS PGE LOCATION ROY ROGERS RD&SCHOLLS FERRY RD,TIGARD CREATED BY DUMITRU ILIOI DATE 5/30/18 ®PORTLAND GENERAL ELECTRIC CO.-ALL RIGHTS RESERVED Rev. 00 ------------------------------------------------------------------- ------------------------------------------------------------------------------------ 14l PVC CONDUITS FOR STANDARD TEMP; SUBDMSION LEGEND wev $ 00004 STUBRFO OUT OF THE 4-u SECONDARY vAULiS iNE[S 2011-45 TEMPORARY SERVICE REQUIFfS 2' $ TIE O NEW AGE FACILITIES TO BE fNSTALLEO 00050 600A A PD-B5" A PHASE OCrIp v3Bi A PHASE (UNLESS o]HERWISE SPECIFIED) 2011-70 r_ Pfmos,fFnCIUTIES�INSTALL FACILRIFS 1P 7.2 244120 PM SOKVA MLB 2 240'120 PM 75KVA NTLRON 644-PGE PADMOUNT VAULT 644-PGE PADMOUNT VAULT Rirv,i°.,Po L m 'I:r"ID PS"IRA crD= ;,oF°,'r CONDurt eE7s+'FENICED1 1.RRiDR`Dp B �•B64 A PHASE O E7D-3382 A PHASE ® r off n w ruF n er u -,,,E. 1 rw rory Rflp 6. _,MOLLS f4RRY RO i ONIP 644-PGF PADMOUNT VAULNTLBT rON-20 PM 50KVA IP 7 644/PGE PADMOUNT VAU0020 PM 50KVA BT m eov�oiD°e uru°i. o eY''�s*oME: _ - �F SIZE WSrrl[.Y'voif0 NOrf: CD - n., corvDwr Is EE Eo.Ar+•' 120 rt A'.. R 0A ' FeACFMPON51RRm J _ rRrKi.....nen r clnrp.v. D DE6INpr.LE.RfPU fro ° 5697 NGRp51 N, � U O 0005] v1 3p3 f / -' D 20P rtM 1. P a IX[6 IMru°oDv fRUIUR�.fO�OOID 2011-TO ut;fb aRF 2<a:4s ^ I [ I) a 1 Ys y PD�i'T 385 e' PD 382 1118'� °o rOeD S o e .RFs rOr.ry r([:Nl:n�r a.2` pUy I •s -- ________ v5rut I_ crlDun! TTO' I .3M u-rx SFBovDUv rvRl. pvr c rRCNDED 6 SisLLEO a bo!. (Po 2113 I u,.Irl E PLuSE Iz "s 504-PGE VAULT DA,V11 rt UR-In 55-332P-PGE DIAMOND PLATE DOOR J 4 , T008.45 \ !' T•n ]- ay] / �.-,. 6 TEMPORARY SERVICE 15OUIRES I- MTA-l'YL `� 'r 1, 1 - O .-__ _ '• < PVC CONDUOS FOR STANDARD I.,-S YT 380 1 r;I-]u N01f3: STURRED OUT OF THE 444 SECONDARY VAULTS TREES Slv FRIENDLY LN ) SRT�tDF�TONS E PGE. r0 A,I- 151 148149 Iso Isi ,, �'�Q I' ' % 1 RDH > D� CONSTRUCTION NOTES: O O RSDEs' ARC .AL PR K SCHDLL'4 FEWFr-RRI I '>+c eErwiErci .c .T 656 r V VT 00052 C O U V7 00035 cNOLEs ERRY-RDr n as � S _ vwLrs. / 41 bl „ NCLOS °. 358 i _..1\ -- -1VT csp p2' ! SM'FOREST FLOLLO ST oIE�'L ''ll' .+ O C.IT iR TO—11—A".CONvcn � Sd ''d r na + m Frlr um 111' O PD 654.ri { OiFflrRiFNG S—'CONDUD ORR IMIM IF, i0 ( s v,Rw[our IOe' 'D 653 MR O 1 237' „ °ROMDf 6 IN -C-1- Rm au � I ,�Fr n.,,,rn l,n,•.n.rvM�u �°'n��,rr�n,a.�M ., O2 M159 r r •r rwu rurc s u '. a� 444-PGE VAULT -=!l- NOTES: Mr-a'1a fM.6 r.a,r•.'n�Y 152 iD b' ti.REK NOTES: Q 168' Q 153 / pp e'� 2-Y RK I.VA T L ro BE srs urc R[amEO.glevv zwa°Rwaa,H•r Mt eurnED D O TERM-A-DUCTS SFE AT EDUrrONS r N h 154 0 ON ALL WALLS -- APPROVED BY R. use AVD 51 50 t9 IB R7 16 RS O 2.TW OF W i0 '� HUF�vro in s�.rtr i.TRTw oe rm,TR.va.WrsT�u.�•-DDc,sl. 155 61 , 6F SET AT FINAL e" w sv,v0 FAS rte• LL r He W 1. ro 357 156T-012- o � APPROVED Br rGE. Flt0'�'I n,u.FF.Rr.VfR°Y 0 O x Do Nor CROSS coca!s a. PD 388 O O PVC BETWEEN KR resp •.m vOu•el ORw eueunrwvs Faro 15] \VAUITs. F,vc nu0 ry rnn cawrrcncF SW GRANITA N .NSTE T L w£(r .7) (� 4 MIrrR TEST glLl- �TtiNC IN uCX Pvc p��r�. „,wr.r b.,orno.l•,w.Rnnl°.r.,casr 111 � VT-600 CRUSHED ".I(MIN)IN) �� TH1NR r o EP r E 11110 RSFwCF AS Y CONDUITS FOR TEMPS pySI 57UI8DOUT OF TUE 444 SECONDARY VAULTS 10.FESLL R[RB7� Pf SOD slcD ARY PEDESTAL S7REE TLR:HT 5T118-W 1 6zIzR VRLLi 14 c\ RRRAMiDRrER ANY "'ATION FROM THIS DCSIGN MUST 6.4.4 VAULT vvmf 3'TERAUAUCTS BE APPROVED BY PGE PROJECT MANAGER 1"""C, Yerr[ vof w'rxF .+R.•moRW. aPcoR m �.eIS.uEMI Q'DL00 TAPER wM n•tF w P,Ovr ODTB EFOSr a vuW°1r ,� T iRm A 1°i.ROaswPGL CONSIRLICTIONDRAWING PGE FACILITIES N07 DRAWN AS-BUILT VERLFfCAT1ON&NESC VIOLATIONS CORRECTED OF ro 70 SCALE ''bs B TNrs DnwTNe n A eRARFneEa REnESENnrgRl RrlANv GEMENT Tn.n�e„m.,,l ua,nolelr,.Ra.«,n FIELD CR.,rm,nw.,. ,• n..0 oR.nF = R EIE[7RK.",PES s IN THE HELD.Ms MAR' mANI,ElEcrtrAL Penmen: Dere: roNNECTrvm.Tms,wD HUMaFRs of coNDuerou.ND RucFivNr of GR,—I Foremen: _ d Ei}IRNAENI MTrNM MF 061RIplrt10N MTFw.n D RECOMMENDED TINT D-; �`� 'L , `'' C D iHf USER NOT RELY ON DtD DIAGRAM FOIE GEWILVNKAL LOGTIONS orvrt m IM fa Feld cDnsfrUcllal eMn m. 48^ t-- Rawlrr a ucom•Rr wu.rn SDPMENG REVIEW: ASBUILi 8Y DESIGNER: � yT-_� DC';pQ\ IM'rs r»in frvosl rra �I •r TMv 2p ® © C uw R 50'S2S1; sem: I':60• n�''"r,10]0001 "d 100000/596 M]T]V]el JOB JTE v war,u, _ CALL III BEFORE YOU DIG r+ RNER TERRACE EAST 13 SUBDMSION i/S •vwrs ceuutto ROCC �' `/-�I}� ,T�ry 8 y r > ORfGON _NODE GeONgC 4R nD ga �GELe 22.31M4YOdl4v CTILTEDng City MED.IRA' .(,D>_23T_NpF, TRENCH DETAIL'A' "o I.'T1Or' A°' 'M°Ov m%Au nH I2o24Dv ASO sERvrcE To NEw ae L SueDMsl REoursr unur.Lou1Es cu"'I oREwr+ fEURFSTRPFa4Br VICINITY MAP rrviss Fwrs�nonE V AFrc.vnoNT lRlwR reR4 WASH co c2i-0e� °F rvp.,[ Dnsl nuAvwu ILFoI d;n =R., ••�R.•� o roRTluro DE nE<rR1c m.-ASE IIDHrs efsmTD