Loading...
Report (92) bko-‘06-kcx RECEVED it NOV 9 2017 BucL-royiNoGr Western States Fire Protection Co. 17500 SW 65th Ave Lake Oswego, OR 97035 Phone (503) 657-5155 Fax (503) 657-5182 k • (3.t 4 " Kelley Imaging Systems 7204 SW Durham Rd. Tigard, OR 97224 WSFP Project #LG1710 Prepared by: Kevin Olson Western States Fire Protection Co. Phone: (503)330-0162 Email: ke, okon(d, s.c Web: Asfp oc-r Nov 3, 2017 n Table of Contents 1. Steel Pipe 2. Fittings and Couplings 3. Sprinkler Heads 4. Hangers r 4 0. a) r L Fittings and Couplings IPS CARBON STEEL PIPE ` 1o� ", HOLE CUT PRODUCTS \IICtaUllia : ,;;;7!' 4-3,.' Style 922 FireLockTM Outlet-T r PRODUCT DESCRIPTION The Style 922 Outlet-T pro- Vds/FM approved for Style 922 is suitable for use A.41/0 vides a convenient method branch connections on wet on standard,lightwall, of incorporating 1/2,�a,and and dry systems. Schedule 5 and other spe- 1"(15,20 and 25 mm)out- cialty pipes.*It is supplied 011 -5..5 lets for directl connectin The locating collar engages y g into the hole prepared in with a clear,rust inhibitive sprinkler heads, drop nip the pipe.When tightened, coating. Contact Victaulic pies,sprigs,gauges,drains the assembly compresses for other optional coatings. N and other outlet products. �� Available for 11/a through the gasket onto the OD of -Consult Section 10.01 for specific L ALO VdS 2W (32 to 65 mm)piping the pipe.Style 922 Outlet-T listings/approvals. is rated to 175 psi(1200 systems, Style 922 outlets See Victaulic are UL/LTLC Listed,LPC, kPa)for fire protection sys- publication 10.01 for details. [LW) tams. • DIMENSIONS1 miff lbw L ii I •Al 1uI Nominal Size inches/ Required Dimensions-inches/ Run X Branch Hole Saw Weight AgE Weight Each FPTt Size T• V W Y _ Z lbs/ 11/4 X 1/ 1346 1.30 1.83 1.10 3.87 2.56 1.0 • 11/4 X'4 13/6 1.28 1.83 1.10 3.87 2.56 1.1 11/4 X 1 13/6 1.52 2.18 1.10 3.87 2.56 1.2 11/2 X / V/6 1.42 1.95 1.22 4.08 2.56 1.2 - 11/2 X 3/4 13/6 1.40 1.95 1.22 4.08 2.56 1.2 11/2 X 1 13/6 1.64 2.30 1.22 4.08 2.56 1.3 2 X 1/2 13A6 1.66 2.19 1.46 4.60 2.56 1.3 2 X 3/4 13/16 1.64 2.19 1.46 4.60 2.56 1.4 2 X 1 13/16 1.88 2.54 1.46 4.60 2.56 1.5 21/2 X 1/2 13/6 1.91 2.44 1.71 5.40 2.56 1.6 21/2 X z1/4 13/16 1.89 2.44 1.71 5.40 2.56 1.6 2/ X 1 13/16 2.13 2.79 1.71 5.40 2.56 1.6 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT(optional)male pipe threads only.Use of male threaded products with special features,such as probes,dry pendent sprinkler heads,etc.,should be verified as suitable for use with this Victaulic product.Failure to verify suitability In advance may,esult in assembly problems or leakage. *Center of run to engaged pipe end for NPT threads(dimensions are approximate). VICTAULIC6 IS AN ISO 9001 CERTIFIED COMPANY Phone:1-800-PICK-VIC(1-800-742-5842) Phone:416-675-5575 Phone:32-9-381-1500 Phone:610-559-3300 Phone:65-235-3035 Fax:610-250-8817 Fax:416-675-5565 Fax:32-9-380-4438 Fax:610-559-3608 Fax:65-235-0535 e-mail:pickvic©victaulic.com e-mail:viccanadaevictaulic.com e-mail:viceuroOvictaulic.be e-mail:vicalevictaulic.com e-mail:vicap@victaulic.com 3355 Rev.A 3/02 3 Registered Trademark of Victaulic 0 Copyright 2002 Victaulic Printed in U.S.A. PERFORMANCE Nominal Size .Equivalent Length of 1"Pipe Feet Inches! 1%X 1 8.5 11/2 X 1 8.5 2 X 1 8.5 2'1X1 8.5 MATERIAL SPECIFICATIONS Housing:Ductile iron conform- Inc.and Approved by Factory tensile strength of 110,000 psi ing to ASTM A-395,grade 65- Mutual Research for wet and (758340 kPa).Flanged hex nut, 45-15,and ASTM A-536,grade dry(oil free air)sprinkler ser- zinc electroplated. 65-45-12 vices up to the rated working Gasket: pressure using the Grade"E" ❑ Grade"E"EPDM-Type A Type A Gasket System. (Violet color code).FireLock Bolts/Nuts:Heat treated car- products have been Listed by bon steel zinc electroplated Underwriters Laboratories track head bolt with a minimum • This product shall be manufactured by Victaulic Company.NI products shall be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. 1.0.52-2 Sprinkler Heads • Vico r • Worldwide www tyco-fire.com Fite PtotecttoP7 Contacts • Products Series TY-B - 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General ambient temperature, concentration of chemicals, and gas/chemical velocity, -- Description should be considered, as a minimum, W,. along with the corrosive nature of the ,,, TYCO Series TY-B, 2.8, 5.6, and 8.0 chemical to which the sprinklers will be " K-factor, Upright and Pendent Sprin- exposed. r 1 I I ilt 4 i iiii klers described in this technical data An intermediate level version of the sheet are standard response,standard Series TY-B Pendent Sprinkler can be i f coverage decorative 5 mm glass bulb obtained by utilizing the Series TY-13 type spray sprinklers designed for use in Pendent Sprinkler in combination with light,ordinary,or extra hazard,commer- the Model S2 Shield. cial occupancies such as banks,hotels, ` Al' shopping malls,factories,refineries,and NOTICE chemical plants. The recessed version of the Series TY-B The Series TY-B Sprinklers described herein must be installed and maintained ,` Pendent Sprinkler,where applicable,is in compliance with this document, as intended for use in areas with a finished well as with the applicable standards of ceiling.It uses a two-piece Style 10(1/2 the National Fire Protection Association _. inch NPT) or Style 40 (3/4 inch NPT) (NFPA),in addition to the standards of f ' i`� Recessed Escutcheon.The Recessed any other authorities having jurisdiction. I Escutcheon provides 1/2 inch(12,7 mm) Failure to do so may impair the perfor- _ of recessed adjustment or up to 3/4 inch mance of these devices. ii (19,1 mm)of total adjustment from the { e flush pendent position.The adjustment The owner is responsible for maintaining provided by the Recessed Escutcheon their fire protection system and devices reduces the accuracy to which the fixed in proper operating condition. Contract pipe drops to the sprinklers must be cut. the installing contractor or product manufacturer with any questions. �` ..e. Corrosion resistant coatings, where applicable,are utilized to extend the life of copper alloy sprinklers beyond that Sprinkler which would otherwise be obtained when exposed to corrosive atmo- identification spheres. Although corrosion resistant coated sprinklers have passed the Numbers (SINS) standard corrosion tests of the appli- cable approval agencies, the testing TY1151 - Upright 2.8K,1/2-NPT is not representative of all possible TY1251 - Pendent 2.8K,1/2"NPT corrosive atmospheres.Consequently, TY3151 - Upright 5.6K,1/2"NPT it is recommended that the end user TY3251- Pendent 5.6K,1/2"NPT be consulted with respect to the suit- TY4151 - Upright 8.0K,3/4"NPT ability of these coatings for any given TY4251 - Pendent 8.0K,3/4"NPT corrosive environment.The effects of TY4851- Upright 8.0K,1/2"NPT TY4951 - Pendent 8.0K,1/2"NPT IMPORTANT Always refer to Technical Data Sheet TFP700 for the `INSTALLER WARNING" that provides cau- tions with respect to handling and installation of sprinkler systems and components.Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 8 NOVEMBER 2014 TFP151 TFP1S1 Page 2 of 8 CEILING PLATE 1 - Frame 5 - Compression SEATING SURFACE 2 - Button Screw 1 iy , _ /� 7 3 AAssembly Sealing 67 - BuDeshing � 7/16" � / 2-1/4" ` 1 4 - Bulb 0 (11,1 mm) (57,2 mm) •All . 3 NOMINAL 1 MAKE-IN /10 ` + 2 *Temperature rating is 1indicated on Deflector. — ' 2-3/16" 1-9/16" _1 (55,6 mm) iI 1 (39,7 mm) 4 I �� 5 ** Pipe thread connections Ale--j e- per ISO 7-1 can be provide1/2"NPT** 1 WRENCH request. on special FLATS UPRIGHT PENDENT CROSS SECTION FIGURE 1 SERIES TY-8 UPRIGHT(TY1151)AND PENDENT(TY/25V SPRINKLERS 2.8 K-FACTOR, 112 INCH NPT,STANDARD RESPONSE *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE 7/16" �.' (11,1 mm) / �r j 03NOMINAL /----1 2-3/16" �� 4 2 MAKE IN i (55,6 mm) • G ' rOA 2 3/16" 1-1/2" ��� I 4-(55,6 mm (38,1 mm) 1 j�__ 5 I „Iltrn 6* 1/2”NPT** I WRENCH STYLE 10 1- 2-7/8"(73,0 mm)DIA. - FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 2 SERIES TY-E3 UPRIGHT(TY3151)AND PENDENT(TY3251)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, STANDARD RESPONSE TFP1S1 Page 3 of 8 *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE rr-� r, t 1 lii �I 1/2` 3 (12,7 mm) / kit NOMINAL /�! 2-5/16" 2 `_�i MAKE-IN (58,7 mm) �� I r(57,2/mm) 1 ' 1-9/16" 1 �f 4 (39,7 mm) 3/4"NPT** I WRENCH STYLE 40 [ - 2-7/8"(73,0 mm)DIA.---j FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 3 SERIES 7Y-B UPRIGHT(7Y4151)AND PENDENT(TY4251)SPRINKLERS 8.0 K-FACTOR,3/4 INCH NPT,STANDARD RESPONSE CEILING PLATE 1 - Frame 5 - Compression SEATING SURFACE 2 - Button Screw 1 3 - Sealing 6 - Deflector* fil'j=�(=m=t i Assembly ------ / 1 �' 3 4 Bulb 7/16" 2-1/4" ) A f (11,1mm) /I$IP (57,2 mm) , 1. 2 M KE IN 1 *Temperature rating is #11111 = 4 indicated on Deflector. 2-3/16" 1-9116" (55,6 mm) i (39,7 mm) . r_o_ ---5 ** Pipe thread connections -- -- —. ...__.— per ISO 7-1 can be 6* provided on special ' 1/2'NPT** T WRENCH request. FLATS UPRIGHT PENDENT CROSS SECTION FIGURE 4 SERIES 7Y-B UPRIGHT(TY4851)AND PENDENT(TY4951)SPRINKLERS 8.0 K-FACTOR, 1/2 INCH NPT,STANDARD RESPONSE TFP1S1 Page 4 of 8 SPRINKLER TEMPERATURE LIQUID BULB SPRINKLER FINISH(81 K TYPE RATING COLOR NATURAL CHROME POLYESTER*** LEAD WAX WAX-OVER-LEAD • BRASS PLATED COATED COATED COATED 135°F(57°C) Orange UPRIGHT 155°F(68°C) Red 2.8 (TY1151) 175°F(79°C) Yellow 1,2,3 1/2" and N/A NPT PENDENT 200°F(93°C) Green (TY1251) Figure 1 286°F(141°C) Blue 360°F(182°C) Mauve 1,2 135°F(57°C) Orange UPRIGHT 155`F(68°C) Red (TY3151) 1,2,3,5 1,2,3,5 and 175°F(79°C) Yellow PENDENT 1,2,3,4.5,6,7, 1,2,3,5 (EN200°F(93°C) Green Figure 2 286°F(141°C) Blue 1**,2** 3** 5** 1** 2** 3",5" 5.6 1/2" 360°F(182°C) Mauve N/A NPT 135°F(57°C) Orange RECESSED 155°F(68°C) Red PENDENT1,2,3,4,5 (TY3251)` 175°F(79°C) Yellow N/A Figure 5 200°F(93°C) Green 286°F(141°C) Blue 1,2 135°F(57°C) Orange UPRIGHT 155°F(68°C) Red (TY4151) 1,2,3,5 1,2,5 and 175°F(79°C) Yellow PENDENT 1,2,3,4,5,6,7 1,2,5 (EN200°F(93°C) Green 2518.0 Figure 3 286°F(141°C) Blue '1",2-- 3",5** 1-* 2**,5** 3/4" 360°F(182°C) Mauve N/A NPT 135°F(57°C) Orange RECESSED 155°F(68°C) Red PENDENT1'2,3'4,5 175°F(79°C) Yellow N/A (TY4251)* Figure 6 200°F(93°C) Green 286°F(141°C) Blue 1,2 135°F(57°C) Orange UPRIGHT 155°F(68°C) Red 8 0 (TY4851) 175`F(79°C) Yellow 1/2" PENDENTand 1,2,3,4,5,6 N/A NPT (TY4951) 200°F(93°C) Green Figure 4 286°F(141°C) Blue 360°F(182°C) Mauve Notes 1. Listed by Underwriters Laboratories,Inc.(UL) 2. Listed by Underwriters Laboratories,Inc.for use in Canada(C-UL) 3. Approved by FM Global(FM Approvals) 4. Approved by the Loss Prevention Certification Board(LPCB Ref.No.007k/03) 5. Approved by the City of New York under MEA 354-01-E 6. VdS Approved(For details contact Tyco Fire Suppression&Building Products,Enschede,Netherlands,Tel.31-53-428-4444/Fax 31-53-428-3377) 7. Approved by the Loss Prevention Certification Board(LPCB Ref.No.094a/05) 8. Where Polyester Coated,Lead Coated,Wax Coated,and Wax-over-Lead Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion- Resistant Sprinklers.Where Lead Coated,Wax Coated,and Wax-over-Lead Coated Sprinklers are noted to be FM Approved,the sprinklers are FM Approved as Corrosion-Resistant Sprinklers. • Installed with Style 10(112-NPT)or Style 40(3/4"NPT)3/4-Total Adjustment Recessed Escutcheon,as applicable • 150°F(66°C)maximum ceiling temperature • Frame and deflector only N/A—Not Applicable • TABLE A SERIES TY-B UPRIGHT AND PENDENT SPRINKLERS LABORATORY LISTINGS AND APPROVALS • TFPIS1 Page 5 of 8 SPRINKLER FINISH K TYPE NATURAL CHROME LEAD WAX WAX-OVER-LEAD BRASS PLATED POLYESTER* COATED COATED COATED 2.8 UPRIGHT(TY1151) 1/2" and 175 psi(12,1 bar) N/A NPT PENDENT(TY1251) UPRIGHT(TY3151) and • 5 6 PENDENT(TY3251) 250 psi(17,2 bar)(a) 1/2" OR NPT 175 psi(12,1 bar) RECESSED PENDENT (TY3251) UPRIGHT(TY4151) and 175 psi(12,1 bar) 8.0 PENDENT(TY4251) 3/4- NPT RECESSED PENDENT 175 psi(12,1 bar) N/A (TY4251) 8.0 UPRIGHT(TY4851) 1/2" and 175 psi(12,1 bar) NPT PENDENT(TY4951) Notes: a. The maximum working pressure of 250 psi(17,2 bar)only applies to the Listing by Underwriters Laboratories,Inc.(UL),the Listing by Underwriters Laboratories,Inc.for use in Canada(C-UL),and the Approval by the City of New York. • Frame and deflector only N/A-Not Applicable • TABLE B SERIES TY-B UPRIGHT AND PENDENT SPRINKLERS MAXIMUM WORKING PRESSURE Technical Physical Characteristics Design Frame Bronze Data Button Brass/Copper Criteria Sealing Assembly Beryllium Nickel Approvals w/TEFLON TYCO Series TY-B, 2.8, 5.6, and UL and C-UL Listed Bulb Glass 8.0 K-factor, Upright and Pendent FM Approved Compression Screw Bronze Sprinklers are intended for fire protec- LPCB Approved Deflector Copper tion systems designed in accordance VdS Approved Bushing(K=2.8) Bronze with the standard installation rules NYC Approved recognized by the applicable Listing (Refer to Table A for complete ap- Operation or Approval agency(e.g.,UL Listing is proval information, including corro- based on the requirements of NFPA sion-resis-tant status.) The glass bulb contains a fluid which 13, and FM Approval is based on the Maximum WorkingPressure expands when exposed to heat.When requirements of the FM Global Loss the rated temperature is reached, the Prevention Data Sheets).Only the Style Refer to Table B. fluid expands sufficiently to shatter the 10 or 40 Recessed Escutcheon, as Discharge Coefficient glass bulb, allowing the sprinkler to applicable, is to be used for recessed K=2.8 gpm/psis/2(40,3 1pmfbar112) activate and water to flow. pendent installations. K=5.6 gpm/psil/2(80,6 1pm/bar1'2) K=8.0 gpm/psis/2(115,2 1pm/bars/2) Temperature Ratings Refer to Table A. Finishes Sprinkler:Refer to Table C. Recessed Escutcheon:Signal or Pure White,Jet Black,Chrome Plated,or Natural Brass • • TFPISI Page6of8 I • 2-7/8"DIA. G (73,0 mm) 3/4"(19,1 mm)5/8±1/4" (15,9±6,4 mm) DIA. t/4"(6,4 mm) 2-1/4WRENCH RECESS " � FACE OF (57,2 mm) �( MOUNTING (END"A" USED FOR 1 SPRINKLER PLATE 1/2"NPT MODELS) FITTING I !� E // ( 1/8" (3,2 mm WRENCH RECESS r '; ' ) 1 ` X11--JiI � — � (END"B"USED FOR T 3/4"NPT MODELS) i // ; Fiir,17.\ � FIGURE 7 MOUNTING/ ltdir f' W TYPE 6 SURFACE SPRINKLER WRENCH / CLOSURE SERIESIS 1-1/4"(31,8 mm)l WRENCH 3/4"(19,1 mm) RECESS FIGURE 5 SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY eni WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT ' - STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT , t _ 2-7/8"DIA. 5/8±1/4" (73,0 mm) 3/4"(19,1 mm) Ilii-.0 r (15,9±6,4 mm) 2-1/4"DIA. 1/4"(6,4 mm) PUSH WRENCH FACE OF (57,2 mm) MOUNTING IN TO ENSURE ENGAGEMENT SPRINKLER ' PLATE WITH SPRINKLER FITTING i I 1/8" WRENCHING AREA / (3,2 mm) FIGURE 8 r W-TYPE 7 RECESSED 1 kaI � i SPRINKLER WRENCH \ /A ��� +` Installation MOUNTING I SURFACE TYCO Series TY-B, 2.8, 5.6, and 8.0 K-factor, Upright and Pendent Sprin- MI CLOSURE SERIES 1-5/16"(33,3 mm) klers must be installed in accordance TY-B 13/16"(20,6 mm) with this section. FIGURE 6 General Instructions SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY Do not install any bulb type sprinkler if WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT the bulb is cracked or there is a loss of STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR,3/4 INCH NPT liquid from the bulb.With the sprinkler held horizontally, a small air bubble should be present.The diameter of the air bubble is approximately 1/16 inch (1,6 mm)for the 135°F (57°C)to 3/32 inch (2,4 mm) for the 360°F (182°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a minimum-to-maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Obtain a leak-tight 3/4 inch NPT sprinkler joint by applying a minimum to maximum torque of 10 to 20 ft-lbs.(13,4 to 26,8 Nm).Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuf- ficient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. TFP151 Page 7 of 8 Upright and Pendent Sprinklers Recessed Pendent Sprinklers Care must be exercised to avoid dam- ' The Series TY-B Upright and Pendent The Series TY-B Recessed Pendent age to the sprinklers before,during,and • Sprinklers must be installed in accor- Sprinklers must be installed in accor- after Installation. Sprinklers damaged dance with the following instructions: dance with the following instructions: by dropping, striking, wrench twist/ Note:Install pendent sprinklers in the Step A. After installing the Style 10 slippage,or the like, must be replaced. pendent position;install upright sprin- or 40 Mounting Plate, as applicable, Also, replace any sprinkler that has a klers in the upright position. over the sprinkler threads and with cracked bulb or that has lost liquid from Step 1.With pipe thread sealant applied pipe thread sealant applied to the pipe its bulb.(Refer to Installation Section.) to the pipe threads, hand-tighten the threads,hand-tighten the sprinkler into The owner is responsible for the inspec- sprinkler into the sprinkler fitting. the sprinkler fitting. tion,testing, and maintenance of their Step B.lighten the sprinkler into the fire protection system and devices in Step 2. Tighten the sprinkler into the sprinkler fitting using only the W-Type compliance with this document, as sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure well as with the 6 Sprinkler Wrench (Figure 7). For applicable standards 8).With reference to Figure 3 or 4,the of the National Fire Protection Asso- wax-coated sprinklers, use an 8 or 10 W_Type 7 Recessed Sprinkler Wrench ciation (e.g., NFPA 25), in addition to inch adjustable wrench.With reference is to be a lied to the the standards of any other authorities to Figures 1 through 4, the W-Type flats. pp sprinkler wrench having jurisdiction.Contact the installing 7 Recessed Sprinkler Wrench or an contractor or product manufacturer with adjustable wrench,as applicable,is to Step C.After the ceiling is installed or any questions. be applied to the sprinkler wrench flats. the finish coat is applied, slide on the Automatic sprinklers are recommended When installingwax-coated sprinklers Style 10 or 40 Closure over the Series p TY-B Sprinkler and push the Closure to be inspected,tested,and maintained with an adjustable wrench, exercise over the Mounting Plate until its flange by a qualified Inspection Service in care to prevent damage to the wax contacts the ceiling. accordance with local requirements coating on the sprinkler wrench flats and/or national codes. or frame arms and, consequently, exposure of bare metal to the corrosive Care and environment. Open the jaws of the wrench sufficiently wide to pass over Maintenance the wrench flats without damaging the wax coating.Before wrench tightening TYCO Series TY-B, 2.8, 5.6, and 8.0 the sprinkler, adjust the jaws of the K-factor, Upright and Pendent Sprin- wrench to contact only the sprinkler klers must be maintained and serviced wrench flats.After wrench tightening the in accordance with this section. sprinkler,loosen the wrench jaws before Before closing a fire protection system removing the wrench. main control valve for maintenance After installation, inspect the sprinkler work on the fire protection system that wrench flats and frame arms and it controls, obtain permission to shut retouch(repair)the wax coating when- down the affected fire protection system ever the coating has been damaged and from the proper authorities and notify all bare metal is exposed.Retouch the wax personnel who may be affected by this coating on the wrench flats by gently action. applying a heated 1/8 inch diameter The owner must assure that the steel rod to the damaged areas of wax, sprinklers are not used for hanging to smooth it back over areas where bare any objects and that the sprinklers are metal is exposed. only cleaned by means of gently dust- ing with a feather duster, otherwise, NOTICE non-operation in the event of a fire or Only retouching of the wax coating inadvertent operation may result. applied to the wrench flats and frame Absence of an escutcheon, which is arms is permitted,and the retouching is used to cover a clearance, may delay to be performed only at the time of the the time to sprinkler operation in a fire initial sprinkler installation. situation. The steel rod should be heated only Sprinklers which are found to be leaking to the point at which it can begin to or exhibiting visible signs of corrosion melt the wax, and appropriate precau- must be replaced. tions need to be taken when handling the heated rod in order to prevent the Automatic sprinklers must never be installer from being burned. painted, plated, coated, or otherwise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated,should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. TFP151 Page 8 of 8 P/N 57 - XXX - X - XXX I i SPRINKLER TEMPERATURE SIN FINISH RATING 530 2.8K UPRIGHT(1/2-NPT) TY1151 1 NATURAL BRASS 135 135°F(57°C) 531 2.8K PENDENT(1/2"NPT) TY1251 3 PURE WHITE(RAL9010)` 155 155°F(68°C) POLYESTER 570 5.6K UPRIGHT(1/2"NPT) TY3151 4 SIGNAL WHITE(RAL9003) 175 175°F(79°C) POLYESTER 571 5.6K PENDENT(1/2"NPT) TY3251 5 JET BLACK(RAL9005)" 200 200°F(93°C) POLYESTER 590 8.0K UPRIGHT(3/4"NPT) TY4151 6 WAX COATED 286 286°F(141°C) 286°F(141°C)MAX 591 8.0K PENDENT(3/4"NPT) TY4251 7 LEAD COATED 360 360°F(182°C) 560 8.0K UPRIGHT(1/2-NPT) TY4851 8 WAX-OVER-LEAD 000 OPEN'" 286°F(141°C)MAX 561 8.0K PENDENT(1/2"NPT) TY4951 9 CHROME PLATED Notes Eastern Hemisphere sales only '" Available In only 8.0K,155°F(68°C)or 200°F(93°C); requires lead time to manufacture ""Available only for 8.0 K-factor TY4151 and TY4251 for use in deluge systems ("OPEN` indicates sprinkler assembly without glass bulb, button,and sealing assembly) TABLE C • SERIES TY-B UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Limited Ordering Wax Sticks (for retouching wrench-damaged Warranty Procedure wax coating) Specify:(specify color,below)Colored For warranty terms and conditions,visit Contact your local distributor for Coded Wax Stick for retouching(specify www.tyco-tire.com. availability. When placing an order, temperature rating)temperature-rated indicate the full product name and Part Series TY-B Sprinklers,P/N(specify) Number(P/N). Black for 135°F(57°C) P/N 56-065-1-135 Red for 155°F(68°C) P/N 56-065-1-155 Sprinkler Assemblies with Yellow for 175°F(79°C) P/N 56-065-1-175 NPT Blue for 200°F(93°C) Thread Connections Specify: and 286°F(141°C) P/N 56-065-1-286 p fy: Series TY-B (specify SIN), (specify K-factor), (specify Upright Note: Each wax stick is suitable for or Pendent) Sprinkler with (specify) retouching up to 25 sprinklers. temperature rating, (specify) finish or coating,P/N(Refer to Table C) Note: The wax used for 286°F (141°C) sprinklers is the same as for 200°F(93°C) Recessed Escutcheon sprinklers,and,therefore,the286°F(141°C) Specify: Style (10 or 40) Recessed sprinkler is limited to the same maximum Escutcheon with(specify)finish,P/N* ceiling temperature as the 200°F(93°C) Refer to Technical Data Sheet TFP770 sprinkler(i.e., 150°F 166°C)). Sprinkler Wrenches Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 1400 Pennbrook Parkway,Lansdale,PA 194461 Telephone+1-215-362-0700 Copyright®2014 Tyco Fire Products,LP. All rights reserved. NCO TEFLON is trademark of the DuPont Corporation. Hangers and Bracing Threaded Accessories B3205-Threaded Rod (right-hand threads - both ends) B3205L-Threaded Rod (right& left hand threads) TL ;;;' Size Range: 3/8"-16 thru 3"-4 rod Specify Length Material: Steel Function: Recommended for use as a hanger support in hanger assemblies. TL Rod is threaded on both ends with right hand threads of the length shown. Also available with left and right hand threads-specify Fig. B3205L when ordering. A r.-\I `:.Thread Size Maximum Temperature: 750°F (399°Ci Finish: Plain. Contact customer service for alternative finishes and materials. Order By: Part number, rod size, length and'finish • Standard design Load Thread Size Thread Length TL 650°F(343°C) 750°F(399°C) Part No. A in. (mm) Lbs. (kN) Lbs. (kN) .B3205-3/s x'L' 3/s-16 21/2° (63.51 TA (3.251 572 (2.54) 83205-1/2 x'1' 1/2"-13 21/2" (63.5) 1350 (6.00) 1057 (4.70) B3205.5/s x'L" 5/8"-11 21/2" (63.5) 2160 (9.61) 1692 (7.52) B3205-3/4 x L. 3/4"-10 3" (76.2) 3230 (14.37) 2530 (11.25) 83205-7h x°L' 7/s"-9 31/2' '(88.9) 4480 (19.93) 3508 (15.60) 83205.1 x'1' 1"-8 4" (101.6) 5900 (26.24) 4620 (20.55) 8320541/8 x"L" 11/8"-7 41/2° (114.3) 7450 (33.14) 5830 ` 125.93) B3205-11/4x'L' 11/4"-7' 5" (127.0) 9500 (42.25) 7440 (33.1J9), B3205-11/2 x'L' 112"-6 6" (152.4) 13800 (61.38) 10807 (48.07) 83205-13/4x'L' 13/4"-5 7" (177.8) 18600 (82.73) 14566 (64,79) B3205-2x'L" 2"-41/2 8" (203.2) 24600 (109.42) 19625 (87.29) a B3205-21/4k"L' 21/4"-41/2 9" (228.6) 32300 (143.67) 25295 (112.51) 83205-21/2 x"L" 21/2"-4 10' (254.0) 39800 (177.03) 31169 (138.64) 33205-23/4x'L" 23/4"-4 11" (279.4) 49400 (219.73) 38687 (172.08) 83205-3x'1.' 3"-4 12" (304.8) 60100 (267.32) 47066 (209.35) ATR - All Threaded Rod 120" (3.05m) Lengths Fig.99-All Threaded Rod Cut To Length f Size Range: 3/8"-16 thru 11/2"-6 rod in 120" (3.05m) lengths or cut to length • i"C� "� Material: Steel („-t.;•:,` "'� Maximum Temperature: 750°F (399'CI Finish: Plain. Contact customer service for alternative finishes and materials. Order By Part number, rod diameter and finish 1 o Part No.-Size x Length Threads Recommended Load Approx.Wt./100 Ft. II ATR Fig.99 Per Inch Lbs. (kN) Lbs. (kg) ATR 1/4"x 120 99-1/4"x length 20 240 (1.07) 12 (5.44) ATR 3/8"x 120 99-3/a"x length 16 730 (3.24) 29 (13.15) ATR 1/2"x 120 99-'/f x length 13 1350 (6.00) 53 (24.04) ATR 5/8"x 120 99-5/s"x length 11 2160 (9.60) 89 (40.37) ATR 3/4"x 120 99-3/4"x length 10 3230 (14.37) 123 (55.79) ATR 7/a"x 120 99-7/s"x length 9 4480 (19.93) 170 (77.11) ATR 1"x 120 99-1"x length 8 5900 (26.24) 225 (102.06) ATR 11/a"x 120 99-11/8"x length 7 7450 (33.14) 280 (127.01) ATR 11/4"x 120 99-11/4"x length 7 9500 (42.25) 351 (159.21) ATR 11/2"x 120 99-11/2"x length 6 13800 (61.38) 510 (231.33) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Pipe Hangers&Supports 238 Eaton • a i°rana of NIBCO Revision 5/24/2001 :.; Fig. 200 (!ti}euj.) "Trimline"Adjustable Band Hanger Size Range- 1/2 thru 8 inch pipe. . I' Material—Carbon Steel, Mil. Galvanized to G-90 specifications. Ill) 41) Function—For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features i (1/2 thru 2 inch)Flared edges ease installation for all BB pipe types and protect CPVC plastic pipe from A abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed • around pipe. • (2-1/2 thru 8 inch)Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. . Approvals—Underwriters'Laboratories Listed (1/2" 1/2 THRU 2 INCH PIPE 2112 THRU 8 INCH PIPE thru 8")in the USA(UL)and Canada (cUL)for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4"thru 8"). Conforms to Federal Specifications WW-H-171 E, Type 10, and Manufacturers Standardization Society SP-69,type 10. r, • Maximum Temperature-650°F. • it i . / /� �� • Finish—Mil. Galvanized,for Stainless Steel materials q� �� �1 / \, * order TOLCOTM Fig. 200WON. ii/ '1,�` G `\ Order ByFigure number and pipe size. I� I/ — g pip � it r j I ��! Pipe Size Rod Size A B Max. Rec. Approx. Inch Metric* Load Lbs. Wt./100 1/2 3/8 8mm or 10mm 3-1/8 2-5/8 400 11 3/4 3/8 8mm or 10mm 3-1/8 2-1/2 400 11 1 3/8 8mm or 10mm 3-3/8 2-5/8 400 12 1-1/4 3/8 8mm or 10mm 3-3/4 2-7/8 400 13 1-1/2 3/8 8mm or 10mm 3-7/8 2-7/8 400 14 2 3/8 8mm or 10mm 4-1/2 3 400 15 2-1/2 3/8 10mm 5-5/8 4-1/8 600 27 3 3/8 10mm 5-7/8 4 600 29 3-1/2 3/8 10mm 7-3/8 5-1/4 600 34 4 3/8 10mm 7-3/8 5 1000 35 5 1/2 12mm 9-1/8 6-1/4 1250 66 6 1/2 12mm 10-1/8 6-3/4 1250 73 8 1/2 12mm 13-1/8 8-3/4 1250 136 " *Order Fig. 200M r Main Office/Manufacturing Facility•1375 Sampson Ave.• Corona,CA 92870• Ph: 909.737.5599• Fax: 909.737.0330 Distribution Center• 8790 Fruitridge Road• Sacramento,CA 95826• Ph: 916.388.7800• Fax: 916.388.1401 89 Manufacturing Facility•4851 Homestead Road,Bldg.118• Houston,TX 77028• Ph: 713.672.0058• Fax: 713.672.0074 www.tolco.com