Loading...
Plans (271) SHEET SEQUENCE AND DETAIL INDEX • NEW ISSUE Q REVISED ISSUE 0 ISSUEDW/NO CHANGES * REVISED-NOTISSUED/SKISSUED FORENSIC IVILIING CO SILTANts CO CO E. 5 o CO 15 82nd Drive,Suite 10 C o CD o N Gladstone,OR 97027 TEL:503.772.1114 ° `_2`. p 1� N H�.. $ y FAX:503.772.4039 Q^ S' .. =N• c Ti, j N c y a,N c www.forensicbuilding.com 2 N U E h o; info©forensicbuilding.com C = h O 2 c 2 . �'d H E COPYRIGHT©2017 FORENSIC SHT# SHEET SEQUENCE AND DETAIL INDEX m SHT# SHEET SEQUENCE AND DETAIL INDEX m o SHT# SHEET SEQUENCE AND DETAIL INDEX m BUILDING CONSULTANTS All Rights Reserved GENERAL 3.00 WALL DETAILS CONTINUED 4.00 WALL OPENING DETAILS OR CCB#155496 0.00 COVER SHEET • 0 4.00 TYPICAL WINDOW FLASHING-INSTALL CONDITION • o 3.19 DOWNSPOUT CLEANOUT ASSEMBLY AT GRADE CLEARANCE • 0 WA FORENW 094308 0.10 SHEET SEQUENCE AND DETAIL INDEX • o WITH FIBER CEMENT PLANK LAP CLADDING UT#8334529-5501 0.11 SHEET SEQUENCE AND DETAIL INDEX • 0 3.20 WING WALL END CAP JOINT AT FIBER CEMENT WALL CLADDING • 0 4.01 A-D TYPICAL VINYL WINDOW INSTALL-ISOMETRIC SEQUENCE • o 0.20 GENERAL NOTES,PROJECT INFO AND CODE ANALYSIS • o SECOND AND THIRD FLOOR LINE THRU-WALL BELLY BAND TRIM 4.02 TYPICAL WINDOW HEAD-CONCEALED COMPONENTS- • ° 3.21 • o INSTALL CONDITION 0.30 ABBREVIATIONS AND SYMBOLS • ° TRANSITION AT FIBER CEMENT PLANK LAP CLADDING TYPICAL WINDOW HEAD-TRIM AND CLADDING 3 22 UPPER WALL BELLY BAND TRIM TRANSITION AT FIBER 4.03 • ° COMPONENTS INSTALL CONDITION • o CEMENT PANEL CLADDING PLANS UPPER WALL BELLY BAND TRIM TRANSITION AT FIBER 4.04 WINDOW HEAD WITH FIBER CEMENT TRIM,TRIM BAND, • ° 1.00 UNIT ADDRESS/BUILDING DESIGNATION-REFERENCE SITE PLAN • 0 3.23 CEMENT PANEL AND SHINGLE PANEL CLADDING DOUBLE BELLY BAND TRIM TRANSITION AT FIBER CEMENT PLANK 4.05 NOT USED 3.24 LAP CLADDING • ° TYPICAL WINDOW JAMB-CONCEALED COMPONENTS- REFERENCE ELEVATION PHOTOS 4.06 INSTALL CONDITION • ° 2.00 BUILDING 1 REFERENCE BUILDING PHOTOS • oHORIZONTAL CLADDING TRANSITION AT FIBER CEMENT 3.25 • ° TYPICAL WINDOW JAMB-TRIM AND CLADDING PLANK LAP AND STONE VENEER CLADDING 4.07 • ° 2.01 BUILDING 2 REFERENCE BUILDING PHOTOS • ° COMPONENTS-INSTALL CONDITION SOFFIT-TO-COLUMN CAP TRANSITION CONDITION 1 AT 2.10 BUILDING 1 FRONT ELEVATION • 0 3.26 •FIBER CEMENT TRIM AND STONE VENEER CLADDING • o WINDOW •JAMB-OUTSIDE CORNER BAY POP-OUT- 2.11 BUILDING 1 REAR ELEVATION • ° SOFFIT-TO-COLUMN CAP TRANSITION CONDITION 2 AT 4.08 INSTALL CONDITION • o PRINT ALL DETAILS IN 2.12 BUILDING 1 LEFT SIDE ELEVATION • 0 3.27 FIBER CEMENT TRIM AND STONE VENEER CLADDING 2.13 BUILDING 1 RIGHT ELEVATION • o SOFFIT TRANSITION DETAIL AT FIBER CEMENT PANEL 4.09 CONDITION • ° 3.28 CLADDING AND PLANK LAP CLADDING • ° TYPICAL WINDOW SILL-CONCEALED COMPONENTS- CLIENT 2.20 BUILDING 2 FRONT ELEVATION • 0 4.10 • o SOFFIT TRANSITION DETAIL AT FIBER CEMENT SHINGLE INSTALL CONDITION 2.21 BUILDING 2 REAR ELEVATION • 0 3.29 • o TYPICAL WINDOW SILL-TRIM AND CLADDING Association of Unit 2.22 BUILDING 2 LEFT SIDE ELEVATION • o PANEL CLADDING AND PLANK LAP CLADDING Owners of Touchstone DOOR ALCOVE SOFFIT TRANSITION DETAIL AT FIBER 4.11 •COMPONENTS-INSTALL CONDITION • ° 2.23 BUILDING 2 RIGHT ELEVATION • o 3.30 CEMENT SHINGLE PANEL CLADDING AND TRIM • ° WINDOW SILL-ALTERNATE TRIM CONFIGURATION AND Townhomes RECESSED GARAGE SOFFIT TRANSITION DETAIL AT FIBER 4.12 CLADDING COMPONENTS-INSTALL CONDITION • ° 3.00 WALL DETAILS 3.31 CEMENT SHINGLE PANEL CLADDING AND DOUBLE TRIM • ° WINDOW HEAD CLADDING JOINTS AT FIBER CEMENT ISSUE SOFFIT TRANSITION DETAIL AT FIBER CEMENT PLANK LAP 4.13 PLANK LAP CLADDING-ISOMETRIC DETAIL • ° TYPICAL BASE OF WALL ASSEMBLY AT FIBER CEMENT SLIDING GLASS DOOR INSTALL AT FIBER CEMENT 3.00 • 0 3.32 • 0 06.05.2018 PLANK LAP CLADDING-ISOMETRIC DETAIL CLADDING AND DOUBLE TRIM •4.14 A-D • o 3.01 TYPICAL SEALANT AND SIDING FASTENER DETAIL • o EXHAUST VENT PENETRATION-TYPICAL MOUNTING BLOCK CLADDING AND FLOR-THRU DECK ASSEMBLY-ISO.SEQ. 3.33 AT FIBER CEMENT CLADDING • 0 4.15 A-D SLIDING GLASS DOOR INSTALL AT FIBER CEMENT • ° Construction Issue Set 3.02 TYPICAL FIBER CEMENT PLANK CLADDING WALL • o CLADDING AND WATERPROOF DECK ASSEMBLY-ISO.SEQ. ASSEMBLY LAP AND FASTENING DETAIL 334 TYPICAL MOUNTING BLOCK AT FIBER CEMENT SIDING- • ° REVISIONS TYPICAL WALL ASSEMBLY FASTENER AND CLEARANCE- ISOMETRIC SEQUENCE 4.16 TYPICAL SLIDING GLASS DOOR HEAD DETAIL AT FIBER • o 3.03 INSTALLATION DETAILS • 0 3.35 EXHAUST VENT PENETRATION AT BELLY BAND TRIM WITH • o CEMENT CLADDING INSTALL CONDITION REV. DATE PIPE PENETRATION MOUNTING BLOCK AND SEALANT AT FIBER CEMENT PLANK LAP CLADDING 4 17 TYPICAL SLIDING GLASS DOOR JAMB DETAIL AT FIBER • o 3.04 • 0 3.36 UTILITY MOUNTING BLOCK WITH PROPER DATA CABLE • o CEMENT CLADDING INSTALL CONDITION FIBER CEMENT PLANK LAP CLADDING AND TRIM TYPICAL SLIDING GLASS DOOR SILL DETAIL AT FLOW-THRU TYPICAL THRU-WALL FLASHING PROFILE AND LAP- PENETRATION AT FIBER CEMENT CLADDING 4.18 • o 3.05 • ° 3.37 SURFACE MOUNTED ELECTRICAL BOX AT FIBER CEMENT CLADDING • o DECK ASSEMBLY-INSTALL CONDITION ISOMETRIC DETAILS TYPICAL SLIDING GLASS DOOR SILL DETAIL AT 3.06 NEW-TO-EXISTING OUTSIDE CORNER JOINT AT FIBER CEMENT • o 3.38 RECESSED FIXTURE/J-BOX WITH MOUNTING BLOCK AT 4.19 • 0 WATERPROOF DECK ASSEMBLY-INSTALL CONDITION • o PLANK LAP CLADDING OVER RAINSCREEN CAVITY FIBER CEMENT CLADDING SWING DOOR INSTALL AT CONCRETE STEP AND FIBER 3.07 OUTSIDE CORNER JOINT CONDITION AT FIBER CEMENT PLANK • ° 3.39 • o HOSE BIBB/PIPE PENETRATION WITH MOUNTING BLOCK AT 4.20 A-D CEMENT CLADDING-ISOMETRIC SEQUENCE • ° LAP CLADDING OVER RAINSCREEN CAVITY FIBER CEMENT CLADDING TYPICAL SWING DOOR HEAD DETAIL AT FIBER CEMENT 3.08 NEW-TO-EXISTING OUTSIDE CORNER JOINT AT FIBER CEMENT • 0 3.40 NON-PENETRATING MOUNTING BLOCK AT FIBER CEMENT • o 4.21 CLADDING-INSTALL CONDITION • 0 PROJECT NAME PLANK LAP CLADDING OVER RAINSCREEN CAVITY PLANK LAP CLADDING TYPICAL SWING DOOR JAMB DETAIL AT FIBER CEMENT 3.09 OUTSIDE CORNER JOINT CONDITION AT FIBER CEMENT PANEL • ° 3.41 • 0 STATIC LOUVER FIXTURE FLASHING WITH MOUNTING 4.22 CLADDING INSTALL CONDITION • ° TO FIBER CEMENT LAP CLADDING OVER RAINSCREEN CAVITY BLOCK AT FIBER CEMENT PLANK LAP CLADDING Touchstone Townhomes OUTSIDE CORNER JOINT CONDITION AT FIBER CEMENT PANEL GANGED UTILITY PENETRATION FLASHING WITH MOUNTING 4.23 TYPICAL SWING DOOR SILL DETAIL AT CONCRETE STEP- • o Targeted Building 3.10 • 0 3.42 • o INSTALL CONDITION CLADDING OVER RAINSCREEN CAVITY BLOCK AT FIBER CEMENT PLANK LAP CLADDING TYPICAL GARAGE DOOR HEAD DETAIL AT FIBER CEMENT Enclosure Rehabilitation 3.11 OUTSIDE 45°CORNER JOINT CONDITION AT FIBER CEMENT • 0 3.43 METER BASE CONDUIT FLASHING AT FIBER CEMENT PLANK 4.24 • ° CLADDING-INSTALL CONDITION • ° PLANK LAP CLADDING OVER RAINSCREEN CAVITY LAP CLADDING TYPICAL GARAGE DOOR JAMB DETAIL AT FIBER CEMENT PROJECT NUMBER INSIDE CORNER JOINT CONDITION AT FIBER CEMENT RECESSED METER BASE HEAD AT FIBER CEMENT PLANK 4.25 • o 3.12 5 0 3.44 • o TRIM AND CLADDING-INSTALL CONDITION (R) 17-091 PLANK LAP CLADDING LAP CLADDING INSIDE 45°CORNER JOINT CONDITION AT FIBER CEMENT RECESSED METER BASE JAMB FLASHING,PLAN VIEW AT 4.26 TYPICAL GARAGE DOOR JAMB DETAIL AT FIBER CEMENT • o 3.13 PLANK LAP CLADDING OVER RAINSCREEN CAVITY • ° 3.45 FIBER CEMENT PLANK LAP CLADDING SAME PLANE TRIM WITH BRACKETED DOWNSPOUT AT 3.46 UTILITY PANEL INSTALLATION-ISOMETRIC SEQUENCE • o SHEET NAME 3.14 FIBER CEMENT TRIM AND CLADDING • ° FIREPLACE VENT FLASHING AT FIBER CEMENT PLANK LAP 5.00 ROOF DETAILS CHANGE IN WALL PLANE CLADDING TRANSITION AT FIBER 3'47 CLADDING • ° 5.00 TYPICAL ROOF FLASHING-ISOMETRIC DETAIL • 0 DRAWING INDEX 3.15 CEMENT CLADDING OVER RAINSCREEN CAVITY • ° 3.48 NOT USED 5.01 ROOF TO WALL APRON FLASHING AT FIBER CEMENT • o HORIZONTAL PANEL JOINT DETAIL AT FIBER CEMENT CLADDING WITH UNDERLAYMENT AT WALL 3.16 • o TOP OF WALL AT EAVE OVERHANG AT FIBER CEMENT PLANK 3.49 ROOF TO WALL STEP FLASHING AT FIBER CEMENT SHEET NUMBER PANEL CLADDING LAP OR SHINGLE PANEL CLADDING • ° 3.17 HORIZONTAL FIBER CEMENT PANEL JOINT TRANSITION • 0 3.50 •TOP OF WALL AT EAVE OVERHANG AT FIBER CEMENT PANEL • 0 5.02 CLADDING-WITH UNDERLAYMENT AT WAL • ° AND COMPONENT ASSEMBLY-ISOMETRIC DETAIL CLADDING 5.03 APRON AND STEP FLASHING TRANSITION-ISOMETRIC DETAIL • o BASE OF WALL FLASHING WITH GRADE CLEARANCE AT 3.18 • ° 3.51 TOP OF WALL TO GABLE/RAKE FASCIA AT FIBER CEMENT • 0 5.04 ROOF VENT ASSEMBLY AT KITCHEN/BATH EXHAUST DUCT • 0 FIBER CEMENT PLANK LAP CLADDING PLANK LAP OR SHINGLE PANEL CLADDING ACTIVE ATTIC VENTILATION UNIT PENETRATION AT 0 1 0 53.52 CORBEL FLASHING INTEGRATION DETAIL AT GABLE/RAKE FASCIA • 0 PITCHED ROOF CONDITION • ° SHEET SEQUENCE AND DETAIL INDEX • NEW ISSUE Q REVISED ISSUE 0 ISSUED W/NO CHANGES * REVISED-NOT ISSUED/SK ISSUED FORENSIC .110116 61156tTAN16 15 82nd Drive,Suite 10 Gladstone,OR 97027 c§ E g TEL:503.772.1114 FAX:503.772.4039 N c 1 www.forensicbuilding.com =N info@forensicbuilding.com 6" 2 3 COPYRIGHT©2017 FORENSIC SHT# SHEET SEQUENCE AND DETAIL INDEX m 0 v o SHT# SHEET SEQUENCE AND DETAIL INDEX SHT# SHEET SEQUENCE AND DETAIL INDEX BUILDING CONSULTANTS All Rights Reserved 6.00 DECK DETAILS OR CCB#155496 6.00A ENLARGED UPPER FLOOR WATERPROOF DECK WA FORENW C94308 • CONDTION AT BUILDING 1 REAR ELEVATOIN UT#8334529-5501 6.006 ENLARGED UPPER FLOOR FLOW-THRU DECK CONDITION •AT AT BUILDING 2 REAR ELEVATION 6.01 FRAMED DECK FLASHING INSTALL AT WATERPROOF DECK • o ASSEMBLY-ISOMETRIC DETAILS BASE OF WALL TO DECK TRANSITION AT WOOD FRAMED 6.02 • WATERPROOF DECK ASSEMBLY DECK EDGE FLASHING TRANSITION AT WOOD FRAMED 6.03 WATERPROOF DECK ASSEMBLY 6.04 DECK EDGE FLASHING WITH GUARDRAIL ATTACHMENT AT • WOOD FRAMED WATERPROOF DECK ASSEMBLY WATERPROOF DECK TO WALL SADDLE FLASHING TRANSITION 6.05 A-B CONDITION 1 AT PERPENDICULAR CONDITION-ISO.SEQ. WATERPROOF DECK TO WALL SADDLE FLASHING TRANSITION 6.06 A-B CONDITION 2 AT PERPENDICULAR CONDITION-ISO.SEQ. PRINT ALL DETAILS IN 6.07 RAIL TO WALL CONNECTION DETAIL AT FIBER CEMENT CLADDING • c COLOR AT 11x17 IAND WATERPROOF DECK COATING ASSEMBLY CLIENT DECK FLASHING ASSEMBLY DIAGRAM AT TYPICAL 6.08 • 0 FLOW-THRU DECK CONDITION-ISOMETRIC DETAIL Association of Unit 6.09 DECK TO WALL FLASHING TRANSITION AT FLOW-THRU • o DECK ASSEMBLY Owners of Touchstone DECK EDGE FLASHING WITH GUARDRAIL ATTACHMENT AT Townhomes 6.10 WOOD FRAMED FLOW-THRU DECK ASSEMBLY 6.11 DECK RAIL TO WALL FLASHING TRANSITION DETAIL AT FIBER o ISSUE •CEMENT CLADDING AND FLOW-THRU DECK ASSEMBLY 6.12 WALL INTEGRATION OF DECK RAIL ASSEMBLY AT FIBER • 0 06.05.2018 CEMENT PLANK LAP CLADDING-ISOMETRIC DETAIL Construction Issue Set REVISIONS REV. DATE PROJECT NAME Touchstone Townhomes Targeted Building Enclosure Rehabilitation PROJECT NUMBER (R) 17-091 SHEET NAME DRAWING INDEX SHEET NUMBER 0. 11 GENERAL NOTES: GENERAL NOTES, CONT.: GENERAL NOTES, CONT.: PROJECT INFORMATION AND CODE ANALYSIS FORENSIC 1. READ DRAWINGS IN CONJUNCTION WITH PROJECT MANUAL MEMBRANE INSTALLATION: PROJECT DESCRIPTION: a I "e 1 11 a CONSIITANTI (SPECIFICATIONS). 15 82nd Drive,Suite 10 1. SEAL WEATHER-RESISTIVE BARRIER AT ALL LAPS AND 1. THE TOUCHSTONE TOWNHOMES ARE A COMMUNITY OF TWO(2)BUILDINGS CONSISTING OF EIGHTEEN(18)PRIVATE 2. DO NOT SCALE DRAWINGS. VERIFY DIMENSIONS ON SITE. TERMINATIONS TO CREATE AIR BARRIER.NOT ALL SEALANT RESIDENCES WITH A REPORTED ORIGINAL CONSTRUCTION YEAR OF 2007.RESIDENCES ARE VARIED BY BUILDING Gladstone,OR 97027 LOCATIONS ARE ILLUSTRATED. TYPES,ORIENTATION,DECK CONFIGURATIONS AND MINOR VARIATIONS OF FINISHES. BUILDINGS ARE EACH WOOD TEL:503.772.1114 3. DRAWINGS OF ELEVATIONS AND SITE PLANS OF THE PROJECT FRAMED CONSTRUCTION OVER CONCRETE FOOTING/WALL FOUNDATIONS AND ARE CLAD IN A COMBINATION OF FIBER FAX:503.772.4039 ARE REPRODUCED FROM BASE DRAWINGS PREPARED BY 2. PROVIDE FURRING STRIPS/RAIN SCREEN BEHIND ALL CEMENT AND STONE VENEER CLADDING TYPES. BUILDING ROOF ASSEMBLIES HAVE EXISTING COMPOSITION www.forensicbuilding.com ORIGINAL ARCHITECT.BRING DISCREPANCIES BETWEEN EXTERIOR CLADDING AND TRIM IN ACCORDANCE WITH THE ASPHALT SHINGLE ROOFING AT PITCHED AND GABLE ROOF ELEMENTS.BUILDINGS INCLUDE WOOD FRAMED infa@forensicbuilding.com DESIGN DOCUMENTS AND ACTUAL PROJECT CONDITIONS TO DRAWINGS,SPECIFICATIONS,AND MANUFACTURER'S WATERPROOF AND FLOW-THRU DECK ASSEMBLY. COPYRIGHT©2017 FORENSIC THE IMMEDIATE ATTENTION OF THE BUILDING ENVELOPE WRITTEN INSTRUCTIONS. BUILDING CONSULTANTS CONSULTANT AND REQUEST A REVIEW. 2. THE TOUCHSTONE TOWNHOMES TARGETED BUILDING ENCLOSURE REHABILITATION(PROJECT)CONSISTS OF All Rights Reserved 3. CLEAN AND PREPARE SURFACE PRIOR TO INSTALLATION OF TARGETED REPAIRS AT THE EXISTING REAR ELEVATIONS AND WATERPROOF AND FLOW-THRU DECK ASSEMBLIES OF 4. EXECUTION OF THE CONTRACT BY THE CONTRACTOR ISA ALL MEMBRANES IN ACCORDANCE TO MANUFACTURERS' EACH BUILDING. OR CCB#155496 REPRESENTATION THAT THE CONTRACTOR HAS VISITED THE RECOMMENDATIONS OR AS DIRECTED BY BUILDING WA FORENW C94308 SITE,BECOME GENERALLY FAMILIAR WITH THE LOCAL ENVELOPE CONSULTANT. 3. TARGETED REPAIRS WILL INCLUDE DECK BOARDS,WATERPROOF DECK COATINGS,LEDGER AND DECK FRAMING UT#8334529-5501 CONDITIONS UNDER WHICH THE WORK IS TO BE PERFORMED DECK POSTS,SOFFITS,BASE-OF-WALL AND STONE VENEER CLADDING CONDITIONS AT DECKS,VINYL WINDOW AND CORRELATED PERSONAL OBSERVATIONS WITH 4. PROVIDE ISOMETRIC METAL SADDLE FLASHING AT PERIMETERS,SLIDING GLASS DOOR PERIMETERS,BELLYBAND TRIM,UTILITY AND VENT PENETRATIONS.THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. INTERSECTIONS AT ROOF PARAPETS AND WALLS;DECK PROPOSED TARGETED SCOPE OF WORK FOR THE BUILDING ENCLOSURE REHABILITATION PROJECT CONSISTS OF CORNERS AND SIMILAR LOCATIONS. THE FOLLOWING: 5. ALL WORK TO BE PERFORMED UNDER THIS SCOPE OF REPAIRS(WORK)SHALL BE CONDUCTED IN FULL COMPLIANCE METAL FLASHING: 4. THE PROPOSED SCOPE OF WORK FOR THE TARGETED BUILDING ENVELOPE REHABILITATION PROJECT CONSISTS OF WITH ALL APPLICABLE LOCAL,STATE,AND FEDERAL LAWS AND THE FOLLOWING: REGULATIONS. IT IS THE CONTRACTOR'S DUTY TO BE 1. INSTALL METAL HEAD FLASHING WITH FOLDED,UPTURNED • 100%REMOVAL AND REPLACEMENT OF EXISTING FIBER CEMENT PANEL CLADDING,REAR ELEVATION TARGETED PLANK LAP FAMILIAR WITH ALL SUCH APPLICABLE LOCAL,STATE,AND END DAMS OVER WINDOWS AND DOORS.CONTRACTOR TO AND SHINGLE PANEL CLADDING.NEW CLADDING FIBER CLADDING TO BE INSTALLED ON 3/8"PRESSURE TREATED FURRING FEDERAL LAWS AND REGULATIONS. FURTHERMORE,THE FIELD VERIFY THAT METAL HEAD FLASHING DOES NOT • 100%REMOVAL OF EXISTING REAR ELEVATION WOOD TRIM MEMBER ELEMENTS AND REPLACEMENT WITH NEW FIBER CEMENT CONTRACTOR SHALL ENSURE THAT ALL ACTIVITIES INTERFERE WITH OPERATION OF WINDOW. TRIM PERFORMED BY THE CONTRACTOR'S PERSONAL EMPLOYEES, • TARGETED REPAIR AT TRANSITIONS FROM STONE VENEER TO ADJACENT FIBER CEMENT CLADDING SUBCONTRACTORS,AND SUPPLIERS COMPLY WITH THESE 2. FORM FLASHINGS WITH A SLOPED HORIZONTAL SURFACE PER • TOP OF WALL TRANSITIONS AT FIBER CEMENTPANEL CLADDING LAWS AND REGULATIONS DURING THE CONSTRUCTION THE FOLLOWING CRITERIA: • ROOF-TO-WALL TRANSITIONS AT FIBER CEMENT SHINGLE PANEL CLADDING PROCESS. • ENSURE A 5%SLOPE AT GREATER THAN OR EQUAL TO A • DECK-TO-BELLY BAND TRIM TRANSITIONS 1-1/2"WIDE HORIZONTAL SURFACE • 100%REMOVAL AND REPLACEMENT OF FLOW-THRU DECK BOARDS,LEDGERS AND FRAMING 6. CONTRACT DRAWINGS ARE COMPLIMENTARY,AND WHAT IS • ENSURE A 10%SLOPE AT LESS THAN A 1-1/2"WIDE • 100%REMOVAL AND REPLACEMENT OF WATERPROOF DECK ASSEMBLIES,SHEATHING,AND FASCIA REQUIRED BY ANY ONE SHALL BE BINDING AS IF REQUIRED BY HORIZONTAL SURFACE - REMOVE AND SAFELY STORE FOR RE-INSTALL EXISTING GUTTER AND DOWNSPOUT ASSEMBLIES AS NECESSARY TO PERFORM ALL.BEFORE STARTING EACH PORTION OF THE WORK, REQUIRED WORK. PRINT ALL DETAILS IN CAREFULLY STUDY AND COMPARE THE VARIOUS DRAWINGS EXTERIOR OPENINGS AND PENETRATIONS: • REMOVE,STORE,AND REINSTALL EXISTING DECK GUARDRAILS WITH FIBER CEMENT MOUNTING BLOCKS COLOR AT 11x17 AND OTHER CONTRACT DOCUMENTS RELATIVE TO THAT • INSTALL METAL AND FLEXIBLE WALL FLASHINGS PER PROJECT DESIGN DOCUMENTS. PORTION OF THE WORK,AS WELL AS INFORMATION 1. ALL SCHEDULES AND QUANTITIES OF WINDOWS,DOORS,AND • EXISTING VINYL WINDOW ASSEMBLIES WITHIN THE SCOPE OF WORK ARE TO BE PULLED AND REINSTALLED WITH ROUGH CLIENT FURNISHED BY OWNER.TAKE FIELD MEASUREMENTS OF ANY VENT PENETRATIONS,AND EXTERIOR FIXTURES,SUCH AS OPENING WRAP,FLASHING AND RELATED COMPONENTS. INSTALL NEW DYNAMIC SEALANT JOINTS AND FIBER CEMENT TRIM AT EXISTING CONDITIONS RELATED TO THAT PORTION OF THE LIGHT FIXTURES,CONVENIENCE RECEPTACLES,EXHAUST ALL WINDOW PERIMETERS. ASSOCIatIOn of Unit WORK AND OBSERVE CONDITIONS AT THE SITE AFFECTING IT. VENTS,PIPE PENETRATIONS,HOSE BIBB,ELECTRICAL OR • EXISTING VINYL SLIDING GLASS DOOR ASSEMBLIES AND SWING DOOR ASSEMBLIES WITHIN THE SCOPE OF WORK ARE TO BE THESE OBLIGATIONS ARE FOR THE PURPOSE OF FACILITATING METERS,ETC.,THAT HAVE BEEN PROVIDED IN THE PULLED AND REINSTALLED WITH ROUGH OPENING WRAP,METAL SILL PAN,METAL FLASHING,AND RELATED COMPONENTS Owners of Touchstone CONSTRUCTION BY THE CONTRACTOR AND NOT FOR THE DOCUMENTS ARE APPROXIMATE AND MUST BE VERIFIED BY INCLUDING NEW DYNAMIC SEALANT JOINTS AND FIBER CEMENT TRIM AT ALL SLIDING GLASS DOOR PERIMETERS. Townhomes PURPOSE OF DISCOVERING ERRORS,OMISSIONS,OR THE CONTRACTOR ON SITE. CONTRACTOR SHALL PERFORM • EXISTING INTERIOR TRIM(AS OCCURS)TO BE REMOVED AT ALL INSTALLED SLIDING GLASS DOORS AND TO BE REPLACED WITH INCONSISTENCIES IN THE CONTRACT DOCUMENTS;HOWEVER, OWN QUANTITY SURVEY AND VERIFIED QUANTITIES OF ALL NEW TO MATCH EXISTING,OR WITH PROFILE AS DIRECTED BY OWNER. REPORT ERRORS,OMISSIONS,OR INCONSISTENCIES ITEMS INDICATED IN THE DRAWINGS. • INSTALL SADDLE FLASHINGS AT DECK CORNERS,AND AT DECK COLUMNS AND POST ASSEMBLIES PER PROJECT DETAILS AND ISSUE DISCOVERED BY THE CONTRACTOR PROMPTLY TO THE SPECIFICATIONS. CONSULTANT AS A REQUEST FOR INTERPRETATION IN THE 2. SEAL INTERIOR AND EXTERIOR WALL PENETRATIONS FOR AIR • INSTALL FLASHING,QUICKFLASH PANELS,AND MOUNTING BLOCKS AT ALL REAR ELEVATION VENTS,UTILITY 06.05.2018 FORM PROVIDED IN THE PROJECT MANUAL. BARRIER CONTINUITY.INSULATE UNDERSIDE OF ALL ROOF PENETRATIONS,LOUVER VENTS,AND PIPE PENETRATIONS. PENETRATIONS 7. REPORT DISCREPANCIES IN CONTRACT DOCUMENTS TO 4. PROJECT BASE BID SCOPE OF REPAIR COMPONENTS TO INCLUDE THE FOLLOWING AREAS OF WORK: Construction Issue Set BUILDING ENVELOPE CONSULTANT FOR CLARIFICATION PRIOR 3. FORM EXTERIOR PERIMETER SEALANT JOINTS 1/2"WIDE WITH • EXTERIOR FIBER CEMENT WALL CLADDINGS TO COMMENCING WORK. CLOSED CELL BACKER ROD U.O.N. MAINTAIN JOINT • WATERPROOF AND FLOW-THROUGH DECK ASSEMBLIES REVISIONS WIDTH:DEPTH RATIO OF 2:1. • PLYWOOD SHEATHING AND WOOD FRAMING MEMBERS 8. IMMEDIATELY NOTIFY BUILDING ENVELOPE CONSULTANT UPON • EXTERIOR WALL PENETRATIONS REV. DATE DISCOVERY OF ADDITIONAL UNFORESEEN DAMAGE TO DRAWING TERMS: - WINDOW ROUGH OPENINGS - EXISTING CONSTRUCTION SCHEDULED TO REMAIN AND THAT • SLIDING GLASS DOOR ROUGH OPENINGS IS OUTSIDE THE CONTRACT. REQUEST A REVIEW.DO NOT 1. DEMOLISH: COMPLETELY REMOVE AND LEGALLY DISPOSE OF • SWING DOOR ROUGH OPENINGS COMMENCE RELATED WORK TO NEARBY WORK WITHOUT OFF-SITE. CONSULTANT APPROVAL. 5. NEW COMPONENTS INCLUDE,BUT ARE NOT LIMITED TO: 2. NEW(ITEM): A TERM USED ON DRAWINGS TO INDICATE THAT AN ITEM • INSULATION 9. TRADE CONTRACTORS ARE RESPONSIBLE FOR THE LAYOUT IS PROVIDED AS NEW WORK. • WOOD FRAMING MEMBERS OF THEIR OWN WORK,AND TO SEE THAT ITS WORK COMES • PLYWOOD SHEATHING TOGETHER WITH THAT OF OTHERS. REPORT DISCREPANCIES 3. PROTECT(ITEM): A TERM USED ON DRAWINGS TO INDICATE AN ITEM • WEATHER-RESISTIVE BARRIER(WRB)AND FLEXIBLE FLASHING ON DRAWINGS TO BUILDING ENVELOPE CONSULTANT FOR REQUIRES PROTECTION FROM THE WORK. • FIBER CEMENT PLANK LAPPED CLADDING DECISIONS. • FIBER CEMENT SHINGLE PANEL CLADDING 4. REMOVE(ITEM):A TERM USED ON DRAWINGS TO INDICATE A • FIBER CEMENT PANEL CLADDING 10. TRADE CONTRACTORS MUST ASSURE THEMSELVES THAT SPECIFIC ITEM TO BE DETACHED FROM EXISTING CONSTRUCTION • FIBER CEMENT TRIM PROJECT NAME THEY HAVE THE LATEST DRAWINGS ISSUED FOR AND LEGALLY DISPOSED OF OFF-SITE,UNLESS INDICATED • FIBER CEMENT MOUNTING BLOCKS CONSTRUCTION,SPECIFICATIONS,MANUFACTURERS' OTHERWISE TO BE REMOVED,SALVAGED,AND REINSTALLED. • CEDAR DECK BOARDS INSTALLATION INSTRUCTIONS AND REFERENCE STANDARDS IN • WATERPROOF PEDESTRIAN DECK COATING Touchstone Townhomes THE CONTRACTOR'S OFFICE. 5. REMOVE AND REINSTALL(ITEM): A TERM USED ON DRAWINGS TO - METAL WALL FLASHING AND THREE-DEMENTIONAL METAL SADDLE FLASHINGS INDICATE A SPECIFIC ITEM TO BE DETACHED FROM EXISTING • SEALANTS Targeted Building 11. DURING REMEDIATION WORK,THE CONTRACTOR IS TO VERIFY CONSTRUCTION,PREPARED FOR REUSE,AND REINSTALLED BACK IN • EXTERIOR PAINTING Enclosure Rehabilitation AND MAINTAIN RATED WALL ASSEMBLIES AT ALL EXISTING ITS EXISTING LOCATION. WALL LOCATIONS. OVERSIGHT IS REQUIRED BY A LICENSED EXISTING USE AND OCCUPANCY: STRUCTURAL ENGINEER TO PROVIDE FRAMING AND 6. RELOCATE(ITEM):A TERM USED IN DRAWINGS TO INDICATE AN PROJECT NUMBER SHEATHING CONDITIONS ASSESSMENT INCLUDING RATED EXISTING ITEM THAT HAS BEEN REMOVED,AND TO BE REINSTALLED 1. ZONING: MUR-1,MAP:1S 1 35AA WALLS WHERE REPAIR WORK IS IDENTIFIED DURING ACTUAL IN A NEW LOCATION 2. COUNTY SEAT: Washington County (R) 17 091 WORK ON THE PROJECT. THE CONTRACTOR IS TO PROVIDE 3. PROPERTY ID: R2159228 AREA SPECIFIC ENGINEERED DRAWINGS SHOWING EXTENT, 7. SALVAGE(ITEM): CAREFULLY DETACH FROM EXISTING 4. STATE ID: 1N2E24DC 90001 DETAILS,AND CALCULATIONS TO THE AUTHORITY HAVING CONSTRUCTION,IN A MANNER TO PREVENT DAMAGE READY FOR 5. PROPERTY CLASS 1020-CONDOMINIUMS JURISDICTION FOR REVIEW AND APPROVAL PRIOR TO REUSE. INCLUDE FASTENERS OR BRACKETS NEEDED FOR 6. NEIGHBORHOOD CODE: 9215 SHEET NAME REMEDIATION WORK. REATTACHMENT IN ORIGINAL LOCATION OR ELSEWHERE. 7. SEISMIC: 'C'for 2008 Oregon Residential Specialty Code CONCEALED BARRIER INSTALLATION: 8. IINDICATE EXISTINGFOISTING ITEITEM):A TERM MS OF CONSTR S DOON N D AT ARE NGS NTO SITE AREAS AND BUILDING HEIGHTS: GEN.ANALYSIS 1. CLEAN AND PREPARE SURFACE PRIOR TO INSTALLATION OF REMOVED AND THAT ARE NOT OTHERWISE INDICATED TO BE 1. SITE AREA: 0.55 AC.(23,958 SF) (UNCHANGED) ALL MEMBRANES IN ACCORDANCE TO MANUFACTURERS' REMOVED,SALVAGED,OR REMOVED AND REINSTALLED.EXISTING 2. BUILDING HEIGHTS: Existing (UNCHANGED) RECOMMENDATIONS OR AS DIRECTED BY BUILDING TO REMAIN IS INDICATED BY GRAPHIC LINETYPE SYMBOL. ENVELOPE CONSULTANT. 3. BUILDING CODES IN EFFECT AT TIME OF REHABILITATION PROJECT: SHEET NUMBER 9. PHASE:A PORTION OF THE WORK TO BE COMPLETED DURING A SET • STATE OF OREGON 2014 OREGON RESIDENTIAL SPECIALTY CODE(O.R.S.C.)AMENDMENTS 2. PROVIDE ISOMETRIC METAL SADDLE FLASHING AT PERIOD OF TIME,AS DEFINED IN THE PROJECT SPECIFICATIONS. (BASED ON 2012 INTERNATIONAL RESIDENTIAL CODE) INTERSECTIONS AT BALCONY/ROOF PARAPET AND WALL; • 2014 OREGON ENERGY EFFICIENCY SPECIALTY CODE(BASED ON THE 2009 INTERNATIONAL ENERGY CODE) DECK CORNERS,SCUPPERS AND SIMILAR LOCATIONS. 10. REFER TO SPECIFICATIONS SUMMARY OF WORK,GENERAL • 2014 OREGON FIRE CODE 0.^O DESCRIPTION OF WORK,FOR SCOPE OF REPAIR ASSEMBLIES. • 2014 OREGON ELECTRICAL SPECIALTY CODE(BASED ON THE 2014 NFPA 70 NATIONAL ELECTRICAL CODE) L • 2014 OREGON PLUMBING SPECIALTY CODE(BASED ON THE 2009 UNIFORM PLUMBING CODE) ABBREVIATIONS: LINETYPE LEGEND: REFERENCE SYMBOLS LEGEND: FORENSIC AL ALUMINUM BUILDING ENVELOPE COMPONENTS- e u i i i a COISIITANTS APPROX APPROXIMATE WINDOWS,DOORS,HOLLOW METAL,VINYL, ARCH ARCHITECTURAL MISC. DETAIL SERIES NUMBER 15 82nd Drive,Suite 10 0 ladstone,BLDG BUILDING SAM-SELF APPLIED MEMBRANE FLEXIBLE GTE L:503.70 72R 11147 BOT BOTTOM FLASHING,OR MANUFACTURED FLASHING FAX:503.772.4039 PANELS AS NOTED www.forensicbuilding.com COL COLUMN WRB-WEATHER RESISTIVE BARRIER info�forensicbuilding.com CONC CONCRETE CONT CONTINUOUS DETAIL NUMBER COPYRIGHT©2017 FORENSIC BUILDING CONSULTANTS CONSTR CONSTRUCTION DECK COATING REINFORCEMENT MESH All Rights Reserved CAN COMPLETE WITH D. DIAMETER POLYURETHANE DECK COATING/CONCRETE OR CCB#155496 DEFS DIRECT-APPLIED FINISH SYSTEM �— WALL DAMPPROOFING DETAIL SERIES NUMBER WA FORENW C94308 UT#8334529-5501 DIM DIMENSION i DWG DRAWING CEMENTITIOUS DECK COATING SYSTEM DS DOWNSPOUT ,_ 0 E. EAST OTHER COMPONENTS-DRAINAGE MAT, EA EACH — REINFORCING MESH,BUG SCREEN, DETAIL NUMBER ELEV ELEVATION FASTENERS,SCREWS,NAILS ELEC ELECTRICAL EIFS EXTERIOR INSULATION&FINISH SYSTEM — EXISTING ROOF UNDERLAYMENT,OTHER EQ EQUAL EXISTING COMPONENTS © STRUCTURAL GRID EQUIP EQUIPMENT LINE DESIGNATION EXIST EXISTING EXT EXTERIOR METAL FLASHING FC FIBER CEMENT i... SEALANT,ADHESIVE FIN FINISH N FRTW FIRE-RETARDANT TREATED WOOD 411 FURR FURRING OR FURRED fPROJECT NORTH ARROW PRINT ALL DETAILS IN GA GAUGE GALV GALVANIZED GWB GYPSUM WALL BOARD DETAIL HATCH PATTERN LEGEND: COLOR ENAT 11x17 GYP GYPSUM Q DELTA REVISION INDICATOR CLIENT HORIZ HORIZONTAL BATT INSULATION Association of Unit OKEYNOTE REFERENCE Owners of Touchstone INT INTERIOR GYPSUM SHEATHING/GYPSUM INSUL INSULATION WALLBOARD Townhomes MAX MAXIMUM ELEVATION DRAWING HATCH MEMB MEMBRANE CONCRETE PATTERN LEGEND: ISSUE MTL METAL 06.05.2018 MIN MINIMUM FIBER CEMENT CLADDING/CEMENT FIBER CEMENT SIDING MISC MISCELLANEOUS BOARD/TILE ADHESIVE N. NORTH DEFS CLADDING Construction Issue Set NTS NOT TO SCALE CONTINUOUS SEALANT BEAD REVISIONS OC ON CENTER SLATE TILE REV. DATE DYNAMIC SEALANT JOINT-SEALANT PLY PLYWOOD APPLICATION OVER CLOSED CELL PT POST-TENSIONED(PRESSURE TREATED BACKER ROD WHEN USED WITH WOOD) �-- _ STONE VENEER(TO REMAIN) POLY POLYETHYLENE w'.1rl $ii DRAINAGE MAT R RADIUS REF REFERENCE REINF REINFORCED ,4),../ RIGID INSULATION/FOAM REQ'D REQUIRED RD ROOF DRAIN S. SOUTH STEEL/METAL SAM SELF ADHESIVE MEMBRANE PROJECT NAME SECT SECTION SIM SIMILAR SPEC SPECIFICATION Touchstone Townhomes SS STAINLESS STEEL STRUC STRUCTURAL ISOMETRIC DRAWING HATCH Targeted Building Enclosure Rehabilitation T&G TONGUE AND GROOVE PATTERN LEGEND: TBD TO BE DETERMINED TEMP TEMPERATURE WRB PROJECT NUMBER TOW TOP OF WALL TYP TYPICAL (R) 17-091 SAM VERT VERTICAL VIF VERIFY IN FIELD SHEET NAME W. WEST METAL FLASHING/COPING/FURRING/TRIM WI W/O WITHTH OUT SYMBOLS WRB WEATHER-RESISTIVE BARRIER CEMENTITIOUS/POLYURETHANE DECK COATING SEALANT SHEET NUMBER TAPE 0.30 FORENSIC BO li OI11 I OIDOiIAllll 15 82nd Drive,Suite 10 Gladstone,OR 97027 Unit 1 Unit 2 Unit 3 Unit 4 Unit 5 Unit 6 Unit 7 Unit 8 Unit 9 Unit 10Unit 11 TEL:503.772.1114 FAX:503.772.4039 I I I 1 I 1 1 + 1 1 www.forensicbuilding.com - - -= info@forensicbuilding.corn COPYRIGHT©2EN BUILDING CONS017ULTANTSFORSIC All Rights Reserved O CCB#155496❑ I I ❑ ❑ I I, I I+ ❑A ❑ I li ❑ I WAFORENWC94308 UT#8334529-5501 ❑ ❑ ❑ ❑ ❑ ❑ - I I - - I �I ❑ ❑ ❑ ❑ ❑0 I 1 ❑ 0 El I ❑ I 0 ❑ 1 I ❑ 0 0 ❑ ❑ ❑ I i` II- H I I' h L ___11 _ ____ Alelr L _ 1 _ PRINT ALL DETAILS IN COLOR AT 11x17 N CLIENT 1 .10 BUILDING 1 ROOF REFERENCE PLAN of Unit ED- Owners of Touchstone 1/16" = 11-011 FOR VENTILATION COORDINATION Townhomes mhg EXISTING BUILDING VENTILATION TABLE ISSUE ATTIC AREA TOTAL PASSIVE INTAKE PASSIVE INTAKE PASSIVE PASSIVE EXHAUST MECHANICAL 06.05.2018 UNIT (SQUARE REQUIRED VENTILATION VENTILATION EXHAUST VENTILATION EXHAUST FEET) VENTILATION REQUIRED(S.F) PROVIDED(S.F) VENTILATION PROVIDED(S.F) PROVIDED Construction Issue Set REQUIRED(S.F) 1 585 S.F. 3.9 S.F. 1.95 S.F. 2.5 S.F. 1.95 S.F. 1.4 S.F. 1,000 CFM REVISIONS 2 585 S.F. 3.9 S.F. 1.95 S.F. 1.0 S.F. 1.95 S.F. 1.4 S.F. 1,000 CFM REV. DATE IIIIIrrilt 40 Unit 41 Unit 42 Unit 43 Unit 44 Unit 45 Unit 46 3 585 S.F. 3.9 S.F. 1.95 S.F. 1.0 S.F. 1.95 S.F. 1.4 S.F. 1,000 CFM I I i I I I 4 585 S.F. 3.9 S.F. 1.95 S.F. 1.0 S.F. 1.95 S.F. 1.4 S.F. 1,000 CFM - - - a a - - - I ^I'- - = - _ - -=1- - _ - 5 585 S.F. 3.9 S.F. 1.95 S.F. 1.0 S.F. 1.95 S.F. 1.4 S.F. 1,000 CFM 6 585 S.F. 3.9 S.F. 1.95 S.F. 1.0 S.F. 1.95 S.F. 1.4 S.F. 1,000 CFM 7 585 S.F. 3.9 S.F. 1.95 S.F. 1.0 S.F. 1.95 S.F. 1.4 S.F. 1,000 CFM I r I' I I' I 8 585 S.F. 3.9 S.F. 1.95 S.F. 1.0 S.F. 1.95 S.F. 1.4 S.F. 1,000 CFM 0 0 ❑ I I ❑ \ ❑ ❑ I 9 585 S.F. 3.9 S.F. 1.95 S.F. 1.0 S.F. 1.95 S.F. 1.4 S.F. 1,000 CFM 10 585 S.F. 3.9 S.F. 1.95 S.F. 1.0 S.F. 1.95 S.F. 1.4 S.F. 1,000 CFM 0 ❑ ❑ ❑ ❑ ❑ \ ❑ 0 11 585 S.F. 3.9 S.F. 1.95 S.F. 2.5 S.F. 1.95 S.F. 1.4 S.F. 1,000 CFM PROJECT NAME I 0 I 0 0 0 I / ❑ ❑ 40 585 S.F. 3.9 S.F. 1.95 S.F. 2.5 S.F. 1.95 S.F. 1.4 S.F. 1,000 CFM Touchstone Townhomes ❑ ❑ I 41 585 S.F. 3.9 S.F. 1.95 S.F. 1.0 S.F. 1.95 S.F. 1.4 S.F. 1,000 CFM Targeted Building 42 585 S.F. 3.9 S.F. 1.95 S.F. 1.0 S.F. 1.95 S.F. 1.4 S.F. 1,000 CFM Enclosure Rehabilitation I' I 43 585 S.F. 3.9 S.F. 1.95 S.F. 1.0 S.F. 1.95 S.F. 1.4 S.F. 1,000 CFM �- -� I I t-- --� 44 585 S.F. 3.9 S.F. 1.95 S.F. 1.0 S.F. 1.95 S.F. 1.4 S.F. 1,000 CFM PROJECT NUMBER I in - J $ - - __ _ + 1[ - 46 585 S.F. 3.9 S.F. 1.95 S.F. 2.5 S.F. 1.95 S.F. 1.4 S.F. 1,000 CFM (R) 17 091 1 1 1 SHEET NAME NOTE: CONTRACTOR TO VERIFY EXISTING ROOF VENTILATION PROVISIONS AND AREA CALCULATIONS REFERENCE PRIOR TO COMMENCEMENT OF WORK. ROOF PLANS 1 .11 BUILDING 2 ROOF REFERENCE PLAN GENERAL NOTES: SHEET NUMBER REFERENCE ROOF PLANS ARE CREATED USING INFORMATION REPRODUCED FROM BASE DRAWINGS ACQUIRED FROM Z - PUBLIC RECORD,AND/OR PREPARED BY ORIGINAUPREVIOUS ARCHITECT,DESIGNER,AND/OR CONSULTANT.BRING ANY 1 . 10 1/1611 = 11-0" FOR VENTILATION COORDINATION DISCREPANCIES BETWEEN DESIGN DOCUMENTS AND ACTUAL PROJECT CONDITIONS TO THE IMMEDIATE ATTENTION OF mhg THE BUILDING ENVELOPE CONSULTANT AND REQUEST A REVIEW. , FORENSIC /111.BI1B CON/1l1ANre 5 82nd Drive,Suite 10 G 10 a k _'YfY'�k 1.'`i k',4',7,77 4 " 'i -��` ,�r, 1Gladstone,OR 97027 R '� 41;:1 .. �d _' i k;� d��"dd;, d 'd d rgljn old t'k,7`rs r1 .; I kd`,i'$1 t - s ., k d�� *11 i' ' g� h d r - TEL 503.772.1114 1 •n_ d r i i FAX 5 r ; 11. I d,J 03.772.ing . . k,,14 0 7 s ,, 1 1'4 " I rl "1 , •k e r a a,r;, i wv✓w.forensicbuildin com S rf d1 d. a d,, t p+ g. nd A .I k.d' 1..,l r I.,jd t d' +,I xid�n.si'adl §'' - .y d,1. .dd '- a�3 d v ;11.:- - •�1A"'SIA ,.,,,,4; �i' y-q F : i, I v ,,1.h i t+115 ,v r.l �, 'R, lr, ,,Ii., r�,. a G infot forensicbuilding.com kd,,'-'11-'4',,-'-'N,r o r° +:1d # )„ fyr ,i a{' .i: �rV„ 'I1'4'� II,la1/: i-1'r, . ' 1'r _-f--.!` � "1 d '. @) ,y, ,,. I I, � rS, .i k � - - COPYRIGHT 02017 FORENSIC rm" t't S an�ran a a �_ I� I, BUILDING CONSULTANT - 17-, _ 0 o 1 1 -�—n -- 1_ r1 — � p I All Rights Reserved ! I 11 I 1 1 }J> r;] 11 ,1, II II i p' j. I I LI 1. jOR CCB#155496 I, i ' lIli' --P-------"•0 {E 1 rI I .i _ , l <: .: I� I I� I (I 11.`1 1 1 1.. ,, 1.,1 ,d... r !! .. — wUT#8334529-550108 I 1 I . 11=7111111M111N1.1 ' ;I i II ___,I ; " +.it l t .. L I,,— rIS1lIl : : ...I �;lidu�I. i !l1. i Il 1I 1 �. I I II iI - rI�' I7N�-� I� �I �� ,In � I ,ta,„,� � , , I o o 88811 HMI t 1 188 II8188 (��I i! i� i o — �� —�� 1� 1 ,, Y 1 11 n. 1 1 I- �j.. I r 'i 'Ill I it 1 t �I 111: (II� I I I t a i � ` `. "� I ._ I - ,-.l � i I ,�I —,®I ��:I ' („r i ,aINMMIMMNIMMIMIMNII�� ( ' i , I , i hll,l i11'� I JIIIII��' ® j '^-.-� : -, 5" moi•' ��_ I +� ®- I 4 n I� Ill Ir i i�l ° .--t: fit At 0r�' -- � r hI® OE 0a O IMi l� al hl Ia o0 00 Ir I g* Im IL; I--- - I I n Li ' - ! f ISO ®®❑ NI MI kW -�-- r- 00 ©o I_I- l® nEj ff� PRINT ALL DETAILS IN COLOR AT 11x17 CLIENT 2.11 BUILDING 1 REAR ELEVATION Association of Unit Owners of Touchstone 3/32° = 11-011 (FOR REFERENCE ONLY) Townhomes ISSUE 06.05.2018 Construction Issue Set REVISIONS b, k a k r k ,.,�• k 1:, I al i: 1] i REV. DATE - 1,1 .% i NI!i! '''.1",'' , d I' "":L." e 1 r P,1. - „1_,,.:,1,1,,,,J,, d I .,,,,i I .I b ' .ire FI84t 1 'Al. : j', eji 9j r d Vii. I—� I,A, I hp 1{d Ip ,, 1 ., i.� 1k l,1 e ' �'9:. i �r "r ,' j. iilk _ r kill +' —B` . own, �.... dk� r 4 a dk COMM' A � �� ' VP k VIE '' d�n1n[• ,114,:,!:, ,, yi4�1 ,, ,, ,, _ u►„ .N J' 1 r d k N 1- .I � �. -- - } c, _ di...' / �_ fiTA•."- ,e • -t i I `f1 1.T—._- ___ =. - ., - \ :.: __ , . d I ,I�/' _ I` _115:�_. -'ro r t x. ��: --�-- - -- E=e.+..a,f,,�sxaas "a' -- ------— ;r.>s .0-:--, ,;-_---'1:::-.'- - -0.00"-- r. . 1 .1I11 � ,./ 1 _ , It I ` ' [7 1E_ I I ., � i ._ JII 1 i , 1 r'1.- -- PROJECT NAME 1 IN ISI j I r^ I ii1111 es a 11. 1I ' I i Touchstone Townhomes I'l ; ) tis.' i t: II Targeted Building ,- i it �. f- — Enclosure Rehabilitation INNEEmmummismi I��- is- a®� ®I h ,111111101111111111111111111111111111.1111111M,mom NM Ia�..I-1 l ]i IIIIIIIIL II L 11 L t l l ) PROJECT NUMBER mon 39 ciEST __ _ 4�L1 rU1.1) i _ elft - �4�1 L X71`� C� 100 Oa - _.: ill ] _ _ — - im — - 17091 liwth �p R. .--------------- �.. r-zirf___ ) I __-rrr -_,no melrsB __.--- � r s� _ .. ;rsrs.e.�-.._.:I?_ �'s" r T - s= _ - �� : -ssr ___:t;'�zr�z a a 1.--3.-41.----------------:-.1.:--;-----%-..x..-1,-..:-:---- - z . �. ,. C-:-;-----:-4a-_ _=-r= _r- :t2 ra'varii-ss_as asl� -sr_g-asses __ _it ....::_11-3:31....r47-.3 -„rx:• - ._r-- - t_ ___- �_ _ ra-ss a -- _ - -vrerr ©© DE © ' t-siasr r -ass — : z: winlr+nrr�ri�n _ +r�as�lvla �dr�rd ,..'. SHEET NAME REFERENCE ELEVATIONS 2.10 BUILDING 1 FRONT ELEVATION SHEET NUMBER 3/3211 = 11-011 (FOR REFERENCE ONLY) 2. 10 NOTE: ALL ELEVATIONS ARE REPRODUCED FROM BASE DRAWINGS PREPARED BY ORIGINAL ARCHITECT. BRING DISCREPANCIES BETWEEN DESIGN DOCUMENTS AND 2. 11 ACTUAL PROJECT CONDITIONS TO THE IMMEDIATE ATTENTION OF THE BUILDING ENVELOPE CONSULTANT AND REQUEST A REVIEW. FORENSIC 8111161110 CAASIIITANTS 15 82nd Drive,Suite 10 Gladstone,OR 97027 TEL:503.772.1114 FAX:503.772.4039 �� www forensicbuilding.com a „dd, info@forensicbuilding.com fm�(�tr Illi nza5t T e"''+ n,VIM �gs COPYRIGHT©2017 FORENSIC f 4 is BUILDING CONSULTANTS rLh.,_I „„,, e :,, „�, ,,;, �„I All Rights Reserved ' d TTShal . al `I ^tl M,0 ea hfd hll N `�Ad ,' ^ i�r{ -t ., a as >�n�a � � °��''.�".�'!� I�i�` OR CCB#155496 WA FORENW C94308 `, ! UT#8334529-5501 lilt r -... I II IN 1 • la ., ;,„ ,, ;, ,, ,.,.. .,.,..„ ,,. .:.:, PRINT ALL DETAILS IN COLOR AT 11x17 CLIENT 2.13 BUILDING 1 LEFT SIDE ELEVATION Association of Unit Owners of Touchstone 3/32" = V1-0” (FOR REFERENCE ONLY) Townhomes ISSUE 06.05.2018 Construction Issue Set REVISIONS 11111,1116=. -- REV. DATE {- I � W1 6 Y P I, d*,,,?,,,6_ „ , 1 1 a A 1 P ylp, 11� ,„„. _,,,,44,,,,,i, Irl. bid tl,.r, Ih p,, ,tC . . , , , __ , . ___ _, t” �j PROJECT NAME Touchstone Townhomes . >f' ., Targeted Building Enclosure Rehabilitation PROJECT NUMBER (R) 17-091 I . i yz„ i.".'i ;#,4i.ft>k .i w -ri�:w3,,A.,, SHEET NAME REFERENCE ELEVATIONS 2.12 BUILDING 1 RIGHT SIDE ELEVATION SHEET NUMBER 3/32" = 11-0" (FOR REFERENCE ONLY) 2. 12 NOTE: ALL ELEVATIONS ARE REPRODUCED FROM BASE DRAWINGS PREPARED BY ORIGINAL ARCHITECT. BRING DISCREPANCIES BETWEEN DESIGN DOCUMENTS AND 2 13 ACTUAL PROJECT CONDITIONS TO THE IMMEDIATE ATTENTION OF THE BUILDING ENVELOPE CONSULTANT AND REQUEST A REVIEW. FORENSIC 8111LOIYB 6C X SI!TANTS 15 82nd Drive,Suite 10 •P "°! ° Gladstone, lad t ne,OR 9702712 4 I' -,' Q _ - FAX:503.772.4039 i� �- www.forensicbuilding.com { �/ :I III 41, - — -', nfo@forenslcbwldmg.com Ti'�y'ti I „.„1„., 11_,,,d10--401--4111,,r,",11:1,,,,,,,:„7-,t7.01..r ;. e I - 1 COPYRIGHT©2017 FORENSIC BUILDING CONSULTANTS _ All Rights Reserved rf — I # CCB#155496 1 I I L WAFORENW C94308 I 1 T I` 1 � JIlL ( _ I ,f "Is r UT#8334529-5501 III 1 I `' 11111 I III , — „„...10 . 1_____1, Is1' L !MC �� �= 1 t ' -_�!I!f L1 LTJ o© i (lam >. ,ar © - ©�, n0 I ' It oil lac •r_ it , t. I �� ®�'I l l�l_I�l II■1 II•I Iwl �.�� frllla ( ��Z- SII II --_- 1, IE®ry !an - O�( L,L.I it-- �..-. i� .__ «l an Lin ©o -__ o PRINT ALL DETAILS IN COLOR AT 11x17 CLIENT 2.21 BUILDING 2 REAR ELEVATION Association of Unit Owners of Touchstone 3/32” = 11-0" (FOR REFERENCE ONLY) Townhomes ISSUE 06.05.2018 Construction Issue Set gg REVISIONS nTa G ", _ �® REV. DATE i I' "' 1 .Tr``, � ' _ a �-i 14 -V4-1,4...-L.',...� 0171p4,'..r ,gyp n a d, 1nJ, q q.. 1 } ,, '; - dI�. rim: +'1 lid -ted , t 'I',' } .::1,+.' I• rH i �_ [, =I� ISI+ 1 ����II t -1-71 ' Il 1 j I, I I II IMIII H1r Id 'j 1 I IIIIIl ( 1111 HII11 I 111111111111111INII11�I1 I + (f :. _ — — : - ,�.. .... PROJECT NAME , [,__ I 1t1111N111 NIffi� 11' I 0 cr 1 + I__ Touchstone Townhomes IN H T 1 __ III lll'll I' I I l -1M1111111II , Targeted Building 1III ��, ,1 1 _..I I l 1111I� h[III�I I, IHIITIlIIiiIflJI� IH11NIl I1 Enclosure Rehabilitation I ' �,� II, © ��� '11, E© i0© �� PROJECT NUMBER I.. �.i i. ( J D© II L IIT ®© n© �® nn' (R) 17091 i 1 ] i I l ! n� 0; :H"min C -' III 'I) X01 nf�� r I I I l j J SHEET NAME REFERENCE ELEVATIONS 2.20 BUILDING 2 FRONT ELEVATION SHEET NUMBER 3/32" = 1T-0" (FOR REFERENCE ONLY) 2.20 NOTE: ALL ELEVATIONS ARE REPRODUCED FROM BASE DRAWINGS PREPARED BY ORIGINAL ARCHITECT. BRING DISCREPANCIES BETWEEN DESIGN DOCUMENTS AND 2.21 ACTUAL PROJECT CONDITIONS TO THE IMMEDIATE ATTENTION OF THE BUILDING ENVELOPE CONSULTANT AND REQUEST A REVIEW. FORENSIC NIII NN I NN L0N51 LI A NIS .V� 15 82nd Drive,Suite 10 Gladstone,OR 97027 TEL:503.772.1114 FAX:503.772.4039 P ;IP j iil,r..r www.forensicbuilding.com h r , 1��� ". info@forensicbuilding.com COPYRIGHT©2017 FORENSIC ti 1 BUILDING CONSULTANTS r All Rights Reserved II OR CCB#155496 WA FORENW 094308 y _ _ UT#8334529-5501 111 NM 1,''Ir['1;11: I A 11111 l 1 J PRINT ALL DETAILS IN COLOR AT 11x17 CLIENT 2.13 BUILDING 2 LEFT SIDE ELEVATION Association of Unit Owners of Touchstone 3/321 = I1-011 (FOR REFERENCE ONLY) Townhomes ISSUE 06.05.2018 Construction Issue Set REVISIONS REV. DATE Illi„'•' dd I_ Tt I i I PROJECT NAME 'I Touchstone Townhomes LiTargeted Building Enclosure Rehabilitation PROJECT NUMBER `== ===_ _ �'ea n---_r_--r. -az=�r (R) 17-091 cagerf _iawEllit*iralWC:i 36=ems r+1E.-r �°1L it*Acral' ry-__tee. / SHEET NAME REFERENCE ELEVATIONS 2.12 BUILDING 2 RIGHT SIDE ELEVATION SHEET NUMBER 3/32" = 11-0" (FOR REFERENCE ONLY) 2.22 NOTE: ALL ELEVATIONS ARE REPRODUCED FROM BASE DRAWINGS PREPARED BY ORIGINAL ARCHITECT. BRING DISCREPANCIES BETWEEN DESIGN DOCUMENTS AND 2.23 ACTUAL PROJECT CONDITIONS TO THE IMMEDIATE ATTENTION OF THE BUILDING ENVELOPE CONSULTANT AND REQUEST A REVIEW. NOTES: FORENSIC 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED WALL ASSEMBLIES. CORRECT INCORRECT e„�L o I v G r O„5 <<f a,z 2. METAL THRU WALL FLASHING IS TO BE COMPLETE WITH UPTURNED ENDS AT TERMINATIONS AND CONTINUOUS 1582nd Drive,Suite 10 AROUND CORNERS. SLOPE HORIZONTAL LEGS TO DRAIN, MIN. 2% Gladstone,OR 97027 3. APPLY PRIMER TO CONCRETE SUBSTRATE PRIOR TO APPLYING SAM. TEL 5037721114 4. SHEET METAL FLASHING IS TO FULLY COVER SAM AND ICE AND WATER SHIELD ENTIRELY FROM UV EXPOSURE. FAX 5037724039 to � www.forensicbuilding.com5. THREE-DIMENSIONAL DRAWINGS ARE INTENDED TO ILLUSTRATE SPECIFIC CONCEPTS OF COMPONENTS info@forensicbuilding.com INSTALLATION. NOT ALL ASSEMBLY COMPONENTS ARE SHOWN. COPYRIGHT©2017 FORENSIC BUILDING CONSULTANTS All Rights Reserved SNUG UNDER DRIVEN OR CCB#155496 WA FORENW C94308 UT#8334529-5501 EXISTING WOOD STUD FRAMING-AT 24”O.C. MAXIP 11:6 FURRING STRIP FORDRAINAGE PLANE CAVITY PRE-FINISHED 26-GAUGE METAL FLASHING PANEL AT JOINT- LAP FLUSH OVERDRIVEN OVER COURSE BELOW, MIN. 6" WI TH CODURSE BELOWMIN. ANDLAPPED ONTO e • �� SCHEDULED WRB ..dil'. s • PRINT ALL DETAILS IN �� -,/.- SCHEDULED FIBER CEMENT ` / 1 PLANK LAP CLADDING ON COLOR AT 11xLS DRAINAGE PLANE CLIENT ro„ CAULK OVERDRIVEN STAPLE Association of Unit SCHEDULED SHEATHING, NAIL AND ADD NAIL Owners of Touchstone REFER TO SPECIFICATIONS Townhomes TYPICAL SIDING NAILING DETAILS ISSUE 06.05.2018 Construction Issue Set 1/2"TYP. SCHEDULED SEALANT REVISIONS ' \ 2:1 RATIO WIDTH TO DEPTI REV. DATE "� SCHEDULED SEALANT TYPICAL A• EXTERIOR 2\ii OVERHANG STARTER STRIP ,� WITH PLANK • INTERIOR L 010 / •• r 1/2"TYP CLOSED CELL NON-GASSING SOFT \ • / PLACE BLIND NAIL HEADS BACKER ROD 25% LARGER THAN 3/4"-1"FROM TOP EDGE AND JOINT PROJECT NAME ` • ••: 6"MIN. CLEARANCE OVERLAP BY 1 1/4" s� ', • a k. ` FROM GRADE TYPICAL STATIC FILLET JOINT Touchstone Townhomes \�/I I TYPICAL DYNAMIC SEALANT JOINT • �� Targeted Building Enclosure Rehabilitation • • •• ,'. PROJECT NUMBER • METAL FLASHING TO PROTECT SAM SEAL (R) 17-091 SAM FLASHING SEAL AT BASE OF SHEATHING SHEET NAME TYPICAL WALL DETAILS 3.00 TYPICAL BASE OF WALL ASSEMBLY 3.01 TYPICAL SEALANT AND SIDING SHEET NUMBER 3" = 1'-0" AT FIBER CEMENT PLANK LAP CLADDING - ISOMETRIC DETAIL N.T.S. FASTENER DETAIL 3.00 mhg 3.00 Wall Details-Touchstone Townhomes.dwg mhg ,O I NOTES: FORENSIC 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED WALL ASSEMBLIES B B i`°'B B B B B B B L I A k I s 2. PRIME AND PREP CLADDING AND TRIM AS REQUIRED TO RECEIVE SEALANT AND PAINT. 1582nd Drive,Suite 10 Gladstone,OR 97027 TEL 503.772.1114 1" MIN CLEARANCE FAX 503.772.4039 www.forensicbui ldingcom info@forensicbu ilding.com SHEATHING COPYRIGHT©2017 FORENSIC SIDING • I BUILDING CONSULTANTS r_ • S1i, ' CC S\0\. �ft WRB All Rights Reserved w 2 1" MIN. z — _ °�� , /g SIDING OR CCB#155496 WOOD STUD 0.C•MAX WOOD STUD ow , \SEPARATION WA FORENW C94308 \,,,__ 24' UT#8334529-5501 WALL SHEATHING " ° WALL SHEATHING v x' 1/4"MIN. CLR.I �b FL„\\f'.... • • Q MTL. FLASHING WRB b S �0 .'Kr` CONCRETE G • TRIM ..._..._ :,...�. 4 ._.,��,� _ a ,.,�- �_ SEALANT 3/4"-1" 1-1/4" 3/ ��,,.�•►'__ o�- OVERLAP KEEP NAILS 3/8"MIN.FROM LAP SIDING EDGES KEEP NAILS 3/4"-1"FROM TOP OF SIDING ai -li 3/8' sr — 11 MINilareil DA FURRING -11111111m MIN11111111111. FIBER CEMENT � - LAP SIDINGBLUE LINE) ' MIL. FLASHING SHINGLE MODERATE _,\ 74m, \ \ WALL SHEATHING PRINT ALL DETAILS IN -BEYOND CONTACT AT pr COLOR AT 11x17 BLIND NAIL, TYP. BUTT JOINT 3/4"-1"FROM f. CLIENT OR 1/8" MAX TOP OF PLANK BLIND NAIL- FIBER CEMENT PLANK LAP CLADDING GAP '. Townhomes Association of Unit IL 31. DRAINAGE MEDIUM NOT SHOWN FOR CLARITY Owners of Touchstone 11/4" 1 1/2" PLASTIC 41 CORRUGATED OVERLAP All FURRING WOOD STUD I. ISSUE 1 WALL SHEATHING 06.05.2018 WOOD STUD 24"O.C. MAX WOOD STUD WOOD STUD WALL SHEATHING --,, WALL SHEATHING FASTENERS AT BUTT JOINT DIAGRAM OVERLAP FOR BLIND AND FACE NAILING Construction Issue Set FIBER CEMENT LAP SIDING FIBER CEMENT LAP SIDING REVISIONS WRB ^ _REV. DATE ..._.. i c .., -.• '""'"..."....". 3/4"-1" 1-1/4" 1/8"MIN.CLEARANCE 1/4"MAX CLEARANCE _,..a�-" " OVERLAP T _4:: FIBER CEMENT CLADDING 3/8" ._,,._ MOP _ 1 = PROJECT NAME - MTL. FLASHING SHINGLE � .. AT BUTT JOINTS Touchstone Townhomes FACE NAIL, TYP. TRIM BOARD / Targeted Building Enclosure Rehabilitation FACE NAIL- FIBER CEMENT PLANK LAP CLADDING FURRING STRIP DRAINAGE MEDIUM NOT SHOWN FOR CLARITY WOOD STUD PROJECT NUMBER (R) 17-091 WALL SHEATHING -- SHEET SHEET NAME SIDING AT TRIM TYPICAL WALL DETAILS 3.02 TYPICAL FIBER CEMENT PLANK CLADDING 3.03 TYPICAL WALL ASSEMBLY FASTENER SHEET NUMBER 3" = 1'-0" WALL ASSEMBLY LAP AND FASTENING DETAIL 3" = l'-0" AND CLEARANCE INSTALLATION DETAILS 3.02 mhg 3.00 Wall Details-Touchstone Townhomes.dwg mhg 3.00 Wall Details-Touchstone Townhomes.dwg 3.03 NOTES: FORENSIC INSTALL SEALANT AT SIDE END 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED WALL ASSEMBLIES BUILDING < M B B t I M w,B DAMS, EXTEND FROM REAR 1/2" MIN. 2. METAL THRU WALL FLASHING IS TO BE COMPLETE WITH UPTURNED ENDS AT TERMINATIONS AND 1582nd Drive,Suite 10 VERTICAL LEG, INTO END DAM UPTURNED FILLET BEAD OF CONTINUOUS AROUND CORNERS. SLOPE HORIZONTAL LEGS TO DRAIN, MIN. 2% Gladstone,OR 97027 SEALANT TEL:503.772.1114 FOLD AND TO DEPTH OF END DAMSAil 3. APPLY PRIMER TO CONCRETE SUBSTRATE PRIOR TO APPLYING SAM. TEL:503.772.4039 DRAINAGE GAP 1/2"WIDTH MAX. 4. SHEET METAL FLASHING IS TO FULLY COVER SAM FROM ALL UV EXPOSURE. www.forensicbuilding.com $1115. ISOMETRIC DRAWINGS ARE INTENDED TO ILLUSTRATE SPECIFIC CONCEPTS OF COMPONENTS info@forensicbui Iding.com COPYRIGHT 02017 FORENSIC SCHEDULED PLANK INSTALLATION. NOT ALL ASSEMBLY COMPONENTS ARE SHOWN. BUILDING CONSULTANTS LAP CLADDING All Rights Reserved NOTE: REFERENCE SECTION • SCHEDULED TRIM WOFORENW C94308 UT#8334529-5501 DETAILS FOR COMPLETE INSTALLATION ` I I 7 I SCHEDULED MOUNTING BLOCK, REFER TO DESIGN MATERIAL(INSTALL WEATHERCUT 2-PIECE BLOCK AS NECESSARY) MAINTAIN A MIN 1/8"CLEARANCE BETWEEN SIDING AND TRIM AND/OR BLOCKING. DO NOT PRINT ALL DETAILS IN COLOR AT 11x17 SPACE MORE THAN 1/4" CLIENT 3.04 PIPE PENETRATION MOUNTING BLOCKAssociation of Unit Owners of Touchstone 3" = 1-0" AND SEALANT AT FIBER CEMENT PLANK LAP CLADDING AND TRIM Townhomes mhg 3.00 Wall Details-Touchstone Townhomes.dwg ISSUE \ \ 06.05.2018 INSTALL 3 CONTINUOUS BEADS OF 3/8"DIAMETER Construction Issue Set 2" FASTENER SEALANT, TYP. REVISIONS ZONE REV. DATE 4" UP \ LEG � METAL FLASHING I , 1/2" END DAM PROJECT NAME 1/2" MIN. t 5%SLOPE @>1-1/2"WIDE DOWN LEG 10%SLOPE @<1-1/2"WIDE Touchstone Townhomes �` 0��-M P � Targeted Building 1/2" HEMMED J HEMMED DRIP EDGE KICK O \/ Enclosure Rehabilitation (REMOVE SHARP EDGES) PROJECT NUMBER 1 TYPICAL FLASHING PROFILE SECTION 2 TYPICAL FLASHING LAP JOINT 3 TYPICAL ALIGNED INSIDE CORNER 4 TYPICAL ADJOINED OUTSIDE CORNER (R) 17-091 NOTE: NOTE: NOTE: NOTE: VERIFY DOWN LEG OF FLASHING DOES NOT IMPEDE SLIP FLASHING TOGETHER FOR A MORE POP-RIVET CORNER OVERLAPS AND SEAL POP-RIVET CORNER OVERLAPS AND SEAL SHEET NAME WITH OPERATION OR VIEW OF WINDOW. DOWN LEG FINISHED APPEARANCE VERSUS STACKING SEAMS TO BE WATER TIGHT SEAMS TO BE WATER TIGHT TYPICAL WALL DIMENSION TO BE VERIFIED DURING MOCK-UP FLASHING DETAILS 3.05 TYPICAL THRU-WALL FLASHING SHEET NUMBER 3" = 18-0" PROFILE AND LAP ISOMETRIC DETAILS 3.04 mhg 3.00 Wall Details-Touchstone Townhomes.dwg 3.05 NOTES: NOTES: FORENSIC 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS BUILDING CCNlIANTS AND MAINTAIN ALL RATED WALL ASSEMBLIES AND MAINTAIN ALL RATED WALL ASSEMBLIES 1582nd Drive,Suite 10 2. CAREFULLY REMOVE EXISTING TRIM, SIDING, WRB AND 2. CAREFULLY REMOVE EXISTING TRIM, SIDING, WRB AND Gladstone,OR97027 ASSOCIATED FLASHINGS AT ELEVATION TO BE ASSOCIATED FLASHINGS AT ELEVATION TO BE TEL:503.772.1114 FAX:503.772.4039 REHABILITATED. REHABILITATED. www.forensicbuilding.corn 3. METAL THRU WALL FLASHING IS TO BE COMPLETE WITH 3. METAL THRU WALL FLASHING IS TO BE COMPLETE WITH info@forensicbuilding corn UPTURNED ENDS AT TERMINATIONS AND CONTINUOUS UPTURNED ENDS AT TERMINATIONS AND CONTINUOUS COPYRIGHT©2017 FORENSIC BUILDING CONSULTANTS AROUND CORNERS AROUND CORNERS All Rights Reserved 4. TRIM TO TUCK UNDER THRU-WALL FLASHING WHERE 4. TRIM TO TUCK UNDER THRU-WALL FLASHING WHERE OR CCB#155496 APPLICABLE. APPLICABLE. WA FORENW 094308 5. PREP TRIM AND CLADDING AS REQUIRED TO RECEIVE 5. PREP TRIM AND CLADDING AS REQUIRED TO RECEIVE UT#8334529-5501 PAINT. PAINT. 6. RUN METAL FLASHING THROUGH ALL EXTERIOR CORNER 6. RUN METAL FLASHING THROUGH ALL EXTERIOR TRIM. CORNER TRIM. 7. NOTIFY CONSULTANT IF EXISTING WRB IS NOT PRESENT. RABBET JOINT 1-SIDE OF RABBET JOINT 1-SIDE OF CORNER TRIM - PRIME CORNER TRIM- PRIME EXISTING CLADDING • �: •'• •. 1/2„ BEFORE INSTALLING TO REMAIN 4 • ' .• 1/2" BEFORE INSTALLING SEALANT(TYP.) • SEALANT(TYP.) EXISTING WRB 1/2" 1/2 j,/ TO REMAIN / PRINT ALL DETAILS IN COLOR AT 11x17 •. .. f: • • •. FULLY SEAL JOIN (TYP.) 1.".......777_,... .,- ��.c• : �: ;a,v.•:.;�t +!4ti•'s' ..I► e�.�•: • ••• •� FULLY SEAL JOIN Y CLIENT TTP. S T(TYP.)a s• • •' — — L I►;n ` �/ SCHEDULED TRIM SIZE Association of Unit �— • • —6"STRIP OF SAM INSTALLED : PER SPECIFICATIONS- Owners of Touchstone O • DIRECTLY ONTO SHEATHING ' s PRIME PRIOR TO SEALANT O ' o )1 't INSTALLATION (TYP.) Townhomes 4" \ ri I \—SCHEDULED TRIM- SIZE PER ISSUE 6„ < SPECIFICATIONS PRIME PRIOR F. 174,1e ' O PSEALANT INSTALLATION '<; 06 05.2018__ 9" (TYP.) �� STATIC FILLET JOINT, STATIC FILLET JOINT(TYP.) Atilt," `� �,P Construction Issue Set I REVISIONS N f 4"LEG OF EXISTING WRB TO 64 1/2„ REV. DATE _ MIN. 9"SAM CENTERED LAP OVER SAM APPLIED F / AT CORNER DIRECTLY ONTO SHEATHING • _3 FIBER CEMENT PLANK LAP 9"STRIP OF SAM TO LAP: M 4"ONTO EXISTING WRB '? CLADDING (SIM.AT ,� 2"ONTO SAM APPLIED SHINGLE PANEL --- - DIRECTLY ONTO SHEATHING CLADDING) -- 3"ONTO NEW WRB , SCHEDULED WRB — ---- -- + SCHEDULED WRB41% ,. 4 PROJECT NAME SCHEDULED SHEATHING Touchstone Townhomes -411111111111110 NSCHEDULED SHEATHING Targeted Building 4101100- C. Enclosure Rehabilitation FIBER CEMENT PLANK LAP N CLADDINGPROJECT NUMBER w SCHEDULED PRESSURE SCHEDULED PRESSURE ,, TREATED FURRING STRIPS (R) 17-091 +,' TREATED FURRING STRIPS J—� ALIGNED WITH STUDS —_ . • ALIGNED WITH STUDS WITH WITH INSECT SCREENS ..................S•••••"*"."") .. `` INSECT SCREENS INSTALLED • --- i I A INSTALLED AT TOP-OF- SHEET NAME AT TOP-OF-WALL AND BASE- WALL AND BASE- OF-WALL TYPICAL WALL OF-WALL TERMINATIONS, TYP. TERMINATIONS, TYP. DETAILS 3.06 NEW-TO-EXISTING OUTSIDE CORNER JOINT 3.07 OUTSIDE CORNER JOINT CONDITION SHEET NUMBER 3" = 1'-0" AT FIBER CEMENT PLANK LAP CLADDING OVER RAINSCREEN CAVITY 3" = 1'-0" AT FIBER CEMENT PLANK LAP CLADDING OVER RAINSCREEN CAVITY 3.06 mhg 3.00 Wall Details-Touchstone Townhomes.dwg mhg 3.00 Wall Details-Touchstone Townhomes.dwg (SIMILAR AT FIBER CEMENT SHINGLE PANEL CLADDING) 3.07 NOTES: NOTES: FORENSIC 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS BUILDING AND MAINTAIN ALL RATED WALL ASSEMBLIES AND MAINTAIN ALL RATED WALL ASSEMBLIES 1582nd Drive,Suite 10 2. CAREFULLY REMOVE EXISTING TRIM, SIDING, WRB AND 2. CAREFULLY REMOVE EXISTING TRIM, SIDING, WRB AND Gladstone,OR 97027 TEL:503.772.1114 ASSOCIATED FLASHINGS AT ELEVATION TO BE ASSOCIATED FLASHINGS AT ELEVATION TO BE FAX:503.772.4039 REHABILITATED. REHABILITATED. www.forensicbuilding.com 3. METAL THRU WALL FLASHING IS TO BE COMPLETE WITH 3. METAL THRU WALL FLASHING IS TO BE COMPLETE WITH nfo@forensicbuilding.com UPTURNED ENDS AT TERMINATIONS AND CONTINUOUS UPTURNED ENDS AT TERMINATIONS AND CONTINUOUS COPYRIGHT©2017 FORENSIC BUILDIRG CONSULTANTS AROUND CORNERS AROUND CORNERS All Rights Reserved 4. TRIM TO TUCK UNDER THRU-WALL FLASHING WHERE 4. TRIM TO TUCK UNDER THRU-WALL FLASHING WHERE OR CCB#155496 APPLICABLE. APPLICABLE. WA FORENW C94308 5. PREP TRIM AND CLADDING AS REQUIRED TO RECEIVE UT#8334529-5501 5. PREP TRIM AND CLADDING AS REQUIRED TO RECEIVE PAINT. PAINT. 6. RUN METAL FLASHING THROUGH ALL EXTERIOR CORNER 6. RUN METAL FLASHING THROUGH ALL EXTERIOR TRIM. CORNER TRIM. 7. NOTIFY CONSULTANT IF EXISTING WRB IS NOT PRESENT. RABBET JOINT 1-SIDE OF CORNER TRIM - PRIME RABBET JOINT 1-SIDE OF . ' , ; 1.0 BEFORE INSTALLING EXISTING FIBER CEMENT CORNER TRIM- PRIME • _4• •J 1/2" SEALANT(TYP.) • PLANK LAP CLADDING TO 4� '•. ' 1/2" BEFORE INSTALLING 1/2" REMAIN SEALANT(TYP.) FIBER CEMENT PLANK EXISTING WRB 1/2";, LAP CLADDING • PRINT ALL DETAILS IN TO REMAIN COLOR AT 11x17 ' FULLY SEAL JOINT(TYP.) `. � FULLY SEAL JOINT(TYP.) CLIENT 7 • . . _�• • . •' �� A...4.:.; t.'.4.:;l' .t•:I. i•: J: ir...i _fie, fie,,• • r.),..r >I ST 4.m....- ' r► - ' ��• r` ��SCHEDULED TRIM -SIZE Association of Unit • 6"STRIP OF SAM INSTALLED ►� '= PER SPECIFICATIONS Owners of Touchstone r ' r r r DIRECTLY ONTO SHEATHING / / / f / :y ► PRIME PRIOR TO SEALANT Townhomes \ T • t� INSTALLATION (TYP.) Atill / 4" •\—SCHEDULED TRIM- SIZE PER ISSUE 6NN \ J,, SPECIFICATIONS- PRIME PRIOR ____ , 06.05.2018 9" ' s TO SEALANT INSTALLATION \ STATIC FILLET JOINT, TYP. \ (TYP) f `. Construction Issue Set Pill v. .� r� STATIC FILLET JOINT(TYP.) �� MIN. 9"SAM CENTERED REVISIONS ` 4" LEG OF EXISTING WRB TO 4 1/2" AT CORNER REV. DATE ___ — a LAP OVER SAM APPLIED — °� _ �1 DIRECTLY ONTO SHEATHING 9"STRIP OF SAM TO LAP: ' ' :7 \, 11 4"ONTO EXISTING WRB 2"ONTO SAM APPLIED \ SCHEDULED WRB DIRECTLY ONTO SHEATHING \ 3"ONTO NEW WRB 6'� EXISTING SHEATHING • \ t PROJECT NAME \ SCHEDULED WRB +� �� SCHEDULED FIBER �; EXISTING SHEATHING \ w CEMENT PANEL CLADDING Touchstone Townhomes "'EWA. ammoo.. 'SCHEDULED FIBER CEMENT PANEL C. Targeted Building \ � CLADDING \ y SCHEDULED PRESSURE Enclosure Rehabilitation TREATED FURRING STRIPS ` �: SCHEDULED PRESSURE TREATED-4111111111. \1,1ALIGNED WITH STUDS WITH PROJECT NUMBER ' FURRING STRIPS ALIGNED WITH ` INSECT SCREENS ------------''– / —�\ ., STUDS WITH INSECT SCREENS !' INSTALLED AT TOP-OF-WALL (R) 17 091 INSTALLAT TOP-OF WALL AND r AND BASE-OF WALL BASE OF WALL TERMINATIONS, TYP. N'r' TERMINATIONS, TYP. SHEET NAME M SCHEDULED BATTENS TO MATCHto SCHEDULED BATTENS TO TYPICAL WALL EXISTING WIDTH AND SPACING MATCH EXISTING WIDTH DETAILS AND SPACING 3.08 NEW-TO-EXISTING OUTSIDE CORNER JOINT 3.09 OUTSIDE CORNER JOINT CONDITION SHEET NUMBER — 3" = 1-0" AT FIBER CEMENT PANEL CLADDING OVER RAINSCREEN CAVITY 3" = 1'-0" AT F. C. PANEL TO F. C. PLANK LAP CLADDING OVER RAINSCREEN CAVITY 3.08 mhg 3.00 Wall Details-Touchstone Townhomes.dwg mhg 3.00 Wall Details-Touchstone Townhomes.dwg 3.09 NOTES: EXAMPLE OF EXISTING OBSERVED FORENSIC 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED WALL ASSEMBLIES CONDITION. PHOTO DOES NOT REPRESENT BUILDING COYSOLIAPIS 2. CAREFULLY REMOVE EXISTING TRIM, SIDING, WRB AND ASSOCIATED FLASHINGS AT ELEVATION TO SCOPE OR VARIATIONS OF CONDITIONS 1582nd Dove,Suite 10 BE REHABILITATED. .,{ � Gladstone,OR97027 3. METAL THRU WALL FLASHING IS TO BE COMPLETE WITH UPTURNED ENDS AT TERMINATIONS AND S 1 TEL 503.772.1 39 1 ,silt FAX 503.772.4039 CONTINUOUS AROUND CORNERS €k www.forensicbuilding.com 4. TRIM TO TUCK UNDER THRU-WALL FLASHING WHERE APPLICABLE. $ nfo@forensicbuilding.com 5. PREP TRIM AND CLADDING AS REQUIRED TO RECEIVE PAINT. 1 L COPYRIGHT©2017 FORENSIC BUILDING CONSULTANTS 6. RUN METAL FLASHING THROUGH ALL EXTERIOR CORNER TRIM. II All Rights Reserved OR CCB#155496 111 ,- ` WA FORENW C94308 tofa. - -- - an UT#8334529-5501 fx RABBET JOINT 1-SIDE OF CORNER . TRIM- PRIME BEFORE INSTALLING i 1. •,�; •.. •• 1/2" SEALANT(TYP.) • SCHEDULED WRB H 1/2"jr/ SEALANT SETTING BED )II\\ \ 41. FILLET BEAD OF SEALANT, # PRINT ALL DETAILS IN • , i TYPICAL SCHEDULED TRIM-SIZE COLOR AT 11x17 CLIENT w_1.i• •"IR.,. :+• IP•: 1.1"•I•i;:•:!:t•,011!i•••e .ri•_S•:r.4__°0;•ti8let� •. PER SPECIFICATIONS 7; . SCHEDULED TRIM -SIZE �. PRIME PRIOR TO SEALANT Association of Unit -.n — i►�•v i= : PER SPECIFICATIONS INSTALLATION (TYP.) Owners of Touchstone � , r / / f PRIME PRIOR TO SEALANT • INSTALLATION (TYP.) ` VII" ` � � MIN. 9"SAM CENTERED AT Townhomes 8 CORNER '1 `` ISSUE £%iijj .:::'*t.1\ y JA' • • 06.05.2018 <6 I �' 4 1/2" '. * Construction Issue Set FILLET BEAD OF FULLY SEAL JOINT(TYP.) t' SEALANT, TYPICAL i .'•+ REVISIONS i:. ;: MIN. 9"SAM CENTERED 'K,, J REV. DATE AT CORNER I — Woo_ t � • STATIC FILLET JOINT, N w� SCHEDULED FIBER CEMENT •' ' TYP. a. PANEL CLADDING �— 10 011111101111" SCHEDULED WRB :. \ • EXISTING SHEATHING PROJECT NAME O N • ^011114110 • .4.\ h, EXISTING SHEATHING 'tr n • SCHEDULED FIBER Touchstone Townhomes �� .. CEMENT PLANK LAP Targeted Building Enclosure Rehabilitation -401111110 SCHEDULED BATTENS CLADDING (SIM.AT 4 TO MATCH EXISTING :tea :+ SHINGLE PANEL %., WIDTH AND DEPTH w CLADDING) PROJECT NUMBER SCHEDULED PRESSURE (R) 17-091 f: TREATED FURRING STRIPS y SCHEDULED PRESSURE Y_ •, �\`` TREATED FURRING ALIGNED WITH STUDS WITH STRIPS ALIGNED WITH SHEET NAME `_ ` t INSECT SCREENS INSTALLED ,., __PC—N ..., C STUDS WITH INSECT —J AT TOP-OF-WALL AND BASE SCREENS INSTALLED AT DWALL ETAILS OF-WALL TERMINATIONS, TYP. TOP-OF-WALL AND BASE OF-WALL TERMINATIONS 3. 10 OUTSIDE CORNER JOINT 3. 11 OITSIDE 45 CORNER JOINT TYP. SHEET NUMBER 3" = 1'-0" CONDITION AT FIBER CEMENT PANEL CLADDING OVER RAINSCREEN CAVITY 3" = 11-0" CONDITION AT F. C. PLANK LAP CLADDING OVER RAINSCREEN CAVITY 3. 10 mhg 3.00 Wall Details-Touchstone Townhomes.dwg mhg 3.00 Wall Details-Touchstone Townhomes.dwg (SIMILAR AT FIBER CEMENT SHINGLE PANEL CLADDING) 3. 11 NOTES: FORENSIC 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS AND PVILDING c u u s a u a x I s MAINTAIN ALL RATED WALL ASSEMBLIES 15 82nd Drive,Suite 10 2. CAREFULLY REMOVE EXISTING TRIM, SIDING, WRB AND Gladstone,OR 97027 ASSOCIATED FLASHINGS AT ELEVATION TO BE REHABILITATED. TEL:503.772.1114 03.772.4039 3. METAL THRU WALL FLASHING IS TO BE COMPLETE WITH FAX: nsicbuilding www.forensicbuilding.com UPTURNED ENDS AT TERMINATIONS AND CONTINUOUS AROUND info@forensicbuilding.com CORNERS COPYRIGHT©2017 FORENSIC BUILDING CONSULTANTS 4. TRIM TO TUCK UNDER THRU WALL FLASHING WHERE `�` All Rights Reserved APPLICABLE. OR CCB#155496 5. PREP TRIM AND CLADDING AS REQUIRED TO RECEIVE PAINT. •,,' •I WA FORENW C94308 6. RUN METAL FLASHING THROUGH ALL EXTERIOR CORNER TRIM. UT r ...i."...... • r.. s .",_•••:.,•„, .. • .; . _• I .: •t..il . 'r. .i.:i ••� 40, , +. \ f 1 I tif `t.:1 41/._ Iillititititill t PRINT ALL DETAILS IN MO ..:;• COLOR AT 11x17 :•• CLIENT /*//.. ` �� _ Associ Owners ofation TouchstoofUnitne --- ` Townhomes • ',� r SCHEDULED WRB ISSUE r, 1/2 EXISTING SHEATHING 06.05.2018 // qie' 4 1/2 I ti STATIC FILLET JOINT, TYP. •ir:••• I�jA'� Construction Issue Set SCHEDULED FIBER CEMENT PLANK SCHEDULED INSIDE CORNER TRIM - 1A0101/ LAP CLADDING (FIBER CEMENT PANEL REVISIONS • •.•� PRIME PRIOR TO SEALANT `/ , AND BATTENS, OR SHINGLE PANEL REV. DATE +� INSTALLATION, (TYP.) _�� , CLADDING SIMILAR) .. MIN. 9"SAM CENTERED AT CORNER :. �� __-_ ,., `) SCHEDULED INSIDE CORNER TRIM - PRIME '•. SCHEDULED FIBER CEMENT PLANK LAP CLADDING 4 1/2 PRIOR TO SEALANT INSTALLATION, (TYP.) • (FIBER CEMENT PANEL AND BATTENS, OR SHINGLE I _ t :s • PANEL CLADDING SIMILAR) . FULLY SEAL JOINT(TYP.) • SCHEDULED WRB ► PROJECT NAME MIN. 9"SAM CENTERED AT CORNER y EXISTING SHEATHING Touchstone Townhomes 7;. `` illTargeted Building ti I � ;• Enclosure Rehabilitation • STATIC FILLET JOINT, TYP. PROJECT NUMBER ,� I: SCHEDULED PRESSURE TREATED FURRING STRIPS ALIGNED WITH STUDS WITH INSECT (R) 17-091 s SCREENS INSTALLED AT TOP-OF-WALL AND H i - SCHEDULED PRESSURE TREATED FURRING ! BASE-OF-WALL TERMINATIONS, TYP. r, STRIPS ALIGNED WITH STUDS WITH INSECT SHEET NAME / SCREENS INSTALLED AT TOP-OF-WALL AND WALL / BASE- OF-WALL TERMINATIONS, TYP. DETAILS 3. 12 INSIDE CORNER JOINT CONDITION 3. 13 INSIDE 45 CORNER JOINT SHEET NUMBER 3" = 1'-0" AT FIBER CEMENT PLANK LAP CLADDING 3" = 1'-0" CONDITION AT F. C. PLANK LAP CLADDING OVER RAINSCREEN CAVITY 3. 12 mhg 3.00 Wall Details-Touchstone Townhomes.dwg mhg 3.00 Wall Details-Touchstone Townhomes.dwg (SIMILAR AT FIBER CEMENT SHINGLE PANEL CLADDING) (SIMILAR AT FIBER CEMENT SHINGLE PANEL CLADDING) 3. 13 EXAMPLE OF EXISTING OBSERVED NOTES: EXAMPLE OF EXISTING OBSERVED F O R E N S I C CONDITION. PHOTO DOES NOT REPRESENT 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED WALL ASSEMBLIES CONDITION. PHOTO DOES NOT REPRESENT e u I l o I G G f G w, <,a„,5 SCOPE OR VARIATIONS OF CONDITIONS 2. CAREFULLY REMOVE EXISTING TRIM, SIDING, WRB AND ASSOCIATED FLASHINGS AT ELEVATION TO BE REHABILITATED. SCOPE OR VARIATIONS OF CONDITIONS 1582nd Drive,Suite 10 — v 3. METAL THRU WALL FLASHING IS TO BE COMPLETE WITH UPTURNED ENDS AT TERMINATIONS AND CONTINUOUS Gladstone,OR 97027 ( t t _ AROUND CORNERS TEL.503.772.1114 is SIP 4. TRIM TO TUCK UNDER THRU-WALL FLASHING WHERE APPLICABLE. FAX nsicbu03 2.4ogs +�#l! '", www.forensicbuilding.com 5. PREP TRIM AND CLADDING AS REQUIRED TO RECEIVE PAINT. info@forensicbuilding.com -,- - 6. RUN METAL FLASHING THROUGH ALL EXTERIOR CORNER TRIM. COPYRIGHT©2017 FORENSIC BUILDING CONSULTANTS t-,.,y All Rights Reserved ` 1 _ ! OR CCB#155496 WA FORENW C94308 UT#8334529-5501 C. -*MENsmai i,.._4 /\ / I . jji,a EXISTINGSHEATHIN SCHEDULEDWRBPRNTLLETIN COLORT1SAM _ „� ._ .� - CLIENT � �•- -a Association c Unit �. T� <, ..r...,.......,......,....,,: �• :,..�,•.�,•... Owners of Touchstone Allil _ Townhomes ! PLYWOOD SHEATHING WRB IssuE • 06.05.2018 2”TYP. i FURRING STRIPS, TYP. EA. SIDE " . .� �' • FIBER CEMENT CLADDING Construction Issue Set )fi REVISIONS _ , 1M FILLET BEAD OF SEALANT, TYPICAL----� •. REV. DATE T �� 4 `m SCHEDULED TRIM- PRIME PRIOR TO SEALANT INSTALLATION, TYP. - ‘• ." .• t{.•"'P--Ia V t" • • • • s • N -fa.ti :, • r i•.J'•�.•"`,'4 �'."'4':: (TYP.) ` r• • '4 I. • MIN. 9"SAM CENTERED AT CORNER, TYP. SCHEDULED PRESSURE _ SCHEDULED FIBER CEMENT TREATED FURRING STRIPS CLADDINGV 1/2"- 1" r WRB CLEARi I-1 \._ FILLET BEAD OF SEALANT, PROJECT NAME TYPICAL 4 1/2" +` FIBER CEMENT CLADDING Touchstone Townhomes SCHEDULED 5/4 FIBER 4 /2" :47, FURRING STRIPS WITH INSECT SCREENS Targeted Building CEMENT TRIM AT TERMINATIONS Enclosure Rehabilitation ! ! / I e 1 �� -� �► SCHEDULED FIBER CEMENT TRIM PRIME PROJECT NUMBER f;701 . _:.'7+ss•1'=~•'sr s3 ''•' - - PRIOR TO SEALANT INSTALLATION (TYP.) (R) 17-091 SCHEDULED DOWNSPOUT AS OCCURS FILLET BEAD OF FULLY SEAL MIN. 9"SAM CENTERED AT CORNER, TYP. SHEET NAME SEALANT, TYPICAL JOINT(TYP.) WALL FILLET BEAD OF SEALANT, TYPICAL DETAILS 3. 14 SAME PLANE TRIM WITH BRACKETED 3. 15 CHANGE IN WALL PLANE SHEET NUMBER 3" = 1'-0" DOWNSPOUT AT FIBER CEMENT TRIM AND CLADDING 3" = 1'-0" CLADDING TRANSITION AT FIBER CEMENT CLADDING 3. 14 mhg mhg 3. 15 NOTES: EXAMPLE OF EXISTING OBSERVED FORENSIC 1. METAL THRU WALL FLASHING IS TO BE COMPLETE WITH UPTURNED ENDS AT CONDITION. PHOTO DOES NOT REPRESENT B U'`0 I B G {°'`""A"" TERMINATIONS AND CONTINUOUS AROUND CORNERS SCOPE OR VARIATIONS OF CONDITIONS 1582nd Drive,Suite 10 2. RUN METAL FLASHING THROUGH ALL INTERIOR AND EXTERIOR CORNER TRIM. Gladstone,OR 97027 3. CONTRACTOR TO VERIFY AND MAINTAIN ALL RATED WALL ASSEMBLIES TEL 503 772 FAX 503.772.4039 www.forensicbuilding.com info@forensicbuild ing.corn COPYRIGHT©2017 FORENSIC BUILDING CONSULTANTS All Rights Reserved _ _ OR CCB#155496 r i. WA FORENW C94308 _,�-`- �'�"--� UT#8334529-5501 - ...oil. I I. • —�- • ire ' �- - 7 —EXISTING SHEATHING SCHEDULED WRB INSTALL SCHEDULED FURRING STRIPS iligle WITH INSECT CI � •1 SCHEDULED FIBER CEMENT PANEL C SCREENS AT HORIZONTAL PRINT ALL DETAILS IN I + / TERMINATIONS COLOR AT 11x17 -�y �• / CLADDING SCHEDULED WRB, SHINGLE LAP OVER CLIENT SCHEDULED PRESSURE TREATED UP LEG OF HEAD FLASHING, 2"MIN. FURRING STRIP WITH INSECT SCREEN Association of Unit AT HORIZONTAL TERMINATIONS INSTALL CONTINUOUS AIR SEAL AT Owners of Touchstone tilliW441111111-""'111111111111 i WRB LAP Townhomes I ; INSTALL SCHEDULED WRB ISSUE '• 1 � 26-GAUGE PRE-FINISHED METAL INSTALL 26-GAUGE PREFINISHED _ 06.05.2018. 40. 1 l i FLASHING, HEM TIGHT, WITH UP- 4" METAL HEAD FLASHING TURNED END DAMS AT Construction Issue Set -.1 1/2" TERMINATIONS EXISTING/SCHEDULED SHEATHING REVISIONS �— —i • L] " it ./ REV. DATE MI5 I : 1.. 1..1/2" . WWI 4. , • SCHEDULED FIBER CEMENT BATTENS �� (BEYOND),ALIGN WITH PANEL JOINTS AND SPACE TO MATCH EXISTING INSTALL SCHEDULED FURRING STRIPS • -�— ' WITH INSECT SCREENS AT HORIZONTAL PROJECT NAME i.; SCHEDULED FIBER CEMENT PANEL TERMINATIONS -'�- ` CLADDING Touchstone Townhomes WIINSTALL SCHEDULED FIBER CEMENT Targeted Building �,� BATTENS,ALIGN WITH PANEL JOINTS Enclosure Rehabilitation � �' AND SPACE TO MATCH EXISTING)4PROJECT NUMBER INSTALL SCHEDULED FIBER CEMENT (R) 17-091 -44111, PANEL CLADDING ` • SHEET NAME WALL DETAILS 3. 16 HORIZONTAL PANEL JOINT DETAIL 3. 17 HORIZONTAL FIBER CEMENT PANEL JOINT SHEET NUMBER 3" = 11-0" AT FIBER CEMENT PANEL CLADDING 1" = 11-0" TRANSITION AND COMPONENT ASSEMBLY- ISOMETRIC DETAIL 3. 16 mhg mhg 3.17 NOTES: A 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS AND MAINTAIN ALL 77_ / METAL DOWNSPOUT FROM FORENSIC° w RATED WALL ASSEMBLIES V •• GUTTER ABOVE, MAINTAIN 1/2"- 1" 1582nd Drive,Suite 10 2. CAREFULLY REMOVE EXISTING TRIM AND ASSOCIATED FLASHINGS AT AREA . STANDOFF FROM FIBER CEMENT Gladstone,OR 97027 TO BE REHABILITATED. TEL:503.772.1114 3. METAL THRU WALL FLASHING IS TO BE CONTINUOUS AROUND CORNERS AND . alliii°v.- i CLADDING www.foFAXrensicbuilding503.772.403.com COMPLETE WITH UPTURNED ENDS AT TERMINATIONS, U.O.N. -�-—= nfo@forensicbuilding.com 4. TRIM TO TUCK UNDER THRU-WALL FLASHING WHERE APPLICABLE. : "� OPTIONAL PRE FINISHED COPYRIGHT©2017FORENSIC 5. PREP AND/OR PRIME TRIM AND CLADDING AS REQUIRED TO RECEIVE PAINT 1 I METAL OPERABLE BUTAIIIRGhtsOReserrved TS i —� 9 AND SEALANT --- SCREEN COVER, OR CCB#155496 6. REVIEW EXISTING CONCRETE PATIO SLABS FOR DRAINAGE CONDITIONS. :. POP-RIVET AT FLANGE WA FORENW C94308 NOTIFY CONSULTANT IF CONCRETE IS BACK SLOPED TOWARDS BUILDING. I %o FOR HINGE. INSURE MIN. UT#8334529-5501 9. SHEET METAL FLASHING IS TO FULLY COVER SAM FROM ALL UV EXPOSURE. ` ���• 1"OPENING ABOVE APPLY PRIMER TO CONCRETE SUBSTRATE PRIOR TO APPLYING SAM. r ..,��� \ COVER FOR OVERFLOW. :.•� PRE-MANUFACTURED AND PRE-FINISHED METAL DOWNSPOUT CLEAN-OUT ` WITH SS CATCH SCREEN, �' EXISTING SHEATHING '�F __ INSTALL PER • '40111111111. MANUFACTURER'S SCHEDULED WRB, LAP OVER SAM AND.., *: 31) ! REQUIREMENTS BASE OF WALL FLASHING BELOW _ y` , PRINT ALL DETAILS IN SCHEDULED PRESSURE TREATED :: ‘iiiiiii .• d COLOR AT 11x17 FURRING STRIP WITH INSECT SCREEN 11111►,` AT HORIZONTAL TERMINATIONS r— 18" CLIENT . ...4011111111110 MIN. '• ; Association of Unit ;" CONTINUOUS SEALANT FOR ,., Owners of Touchstone ••E AIR-SEAL . •" e# Townhomes ' R • FIBER CEMENT PLANK LAP ... s i 1' ! FIBER CEMENT LAP ISSUE 2" CLADDING • CLADDING, TYP. 6" MIN. ,", 06.05.2018 ,` SAM (REFER TO SHEET NOTES) ,* "' .,.•' Construction Issue Set V• • • 4 ^4 4 REVISIONS • • • \• I. Q • 1 REV. DATE •. r j 1/2" • C T_ ••" •�4 . 2" \ MIN. \ • MIN. ( AT GRADE STORM DRAIN I • CONNECTION TO GUTTER 4 C 4 24-GAUGE PRE-FINISHED , 4 A 4, DOWNSPOUT, MODIFY AS FLASHING WITH BACK HEM ,,�_ REQUIRED TO D, MIN. (REFER TO SHEET NOTES) • A4 j ACCOMMODATE 4 . I DOWNSPOUT DIMENSIONS / \ •ti • • 4 1..........._.1 6" PROJECT NAME • 4 4 • �} • 4 _ AN 4 • I MIN. / • . - / a • , •\ Touchstone Townhomes Targeted Building \ \ 4 \77:* r— / \ 4 \/7-\- EEnclosure Rehabilitation \ ® / • \• \//\ PROJECT NUMBER • A • 47\\\(/' . • 4"\./\\ ///\\Y\EXI TINf� /• // A 4 d' n - '. / ,/'\i4 E (R) 17-091 V� 4 � SHEET NAME . \ o \ \\/ \ >\,• _ o // w '/A\\ ` />ss\ /` /! \ // , , - \ // ' '\ S` // WALL Y DETAILS 3. 18 BASE OF WALL FLASHING 3. 19 DOWNSPOUT CLEANOUT ASSEMBLY SHEET NUMBER 3" = 1'-0" WITH GRADE CLEARANCE AT FIBER CEMENT LAP CLADDING 3" = 1'-0" AT GRADE CLEARANCE WITH FIBER LAP CEMENT CLADDING 3. 18 mhg mhg 3. 19 EXAMPLE OF EXISTING OBSERVED NOTES: FORENSIC CONDITION. PHOTO DOES NOT REPRESENT 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED WALL ASSEMBLIES BUILDING COMSULTANIS SCOPE OR VARIATIONS OF CONDITIONS 2. CAREFULLY REMOVE EXISTING TRIM AND ASSOCIATED FLASHINGS AT AREA TO BE REHABILITATED. 15 82nd Drive,Suite 10 rzo 3. METAL THRU WALL FLASHING IS TO BE CONTINUOUS AROUND CORNERS AND COMPLETE WITH Gladstone,OR 97027 TEL:503.772 1114 � UPTURNED ENDS AT TERMINATIONS, U.O.N. FAX 503.772.4039 ':t 4. TRIM TO TUCK UNDER THRU-WALL FLASHING WHERE APPLICABLE. www.forensicbuilding.corn 5. PREP AND/OR PRIME TRIM AND CLADDING AS REQUIRED TO RECEIVE PAINT AND SEALANT nfo@forensicbuilding.com `'' 6. SHEET METAL FLASHING IS TO FULLY COVER SAM FROM ALL UV EXPOSURE.APPLY PRIMER TO COPYRIGHT©2017 FORENSIC BUILDING CONSULTANTS CONCRETE SUBSTRATE PRIOR TO APPLYING SAM. All Rights Reserved OR CCB#155496 WA FORENW C94308 UT#8334529-5501 / � �- • SCHEDULED WRB, LAP OVER WRB V _; �,� AND THRU-WALL FLASHING BELOW EXISTING FIBER CEMENT v� CLADDING, REMOVE AND ' I CONTINUOUS SEALANT j. REPLACE AS NECESSARY TO i , INSTALL SAM AND SCHEDULED MIN. SCHEDULED FIBER CEMENT PLANK LAP PRINT ALL DETAILS IN >.< >< y TRIM AT END WALL CONDITION. CLADDING COLOR AT 11x17 � � % 2„ 24 GAUGE PRE FINISHED METAL HEAD CLIENT r� f• 111%) i . A FLASHING WITH HEMMED DRIP EDGE '� SET IN CONTINUOUS BED OF SEALANT Association of Unit ` Li \ Owners of Touchstone :� ` A ., Townhomes si• __ _7 4" ISSUE 06.05.2018 it.*Mp. EXISTING WRB TO REMAIN 4 i, _____i_Nr s, s 410111) ,, • Construction Issue Set it A L EXISTING SHEATHING � 1„ REVISIONS IN it Liiil/2U REV. DATE �' \ SCHEDULED 5/4 HORIZONTAL FIBER s i. CEMENT TRIM BAND, RABBET BASE i i FOR INTEGRATION WITH LAPPED — ?".. CLADDING BELOW- PRIME PRIOR ,y TO SEALANT INSTALLATION —STATIC FILLET ti SAM TO WRAP END OF JOINT(TYP.) t� 1� PRIVACY WALL, EXTEND SEALANT FILLET BEAD PROJECT NAME Nle, s ,';� 2" MIN. PAST TRIM ONTO SCHEDULED FIBER CEMENT LAPPED iwilm... ii 4 1/2" " EXISTING WRB ti CLADDING Touchstone Townhomes TargeBuilding f—FIBER CEMENT TRIM SCHEDULED PRESSURE TREATED Enclosure Rehabilitation '• MATCH EXISTING ORAS FURRING STRIP WITH INSECT SCREEN FULLY SEAL I i r } r APPROVED DURING h AT HORIZONTAL TERMINATIONS JOINT, TYPICAL •• PROJECT NUMBER '. �► I _-1 �K -1 MOCK-UPS, PRIME r' • . ., �o. _ ':f:,;• r :•r• - -» • . PRIOR TO SEALANT j SCHEDULED WRB (R) 17-091 .4 i INSTALLATION, (TYP.) Oil.1 7 ' • EXISTING SHEATHING SHEET NAME WALL SCHEDULED PRESSURE l I NOTE: BELLY BAND LOCATION DETAILS TREATED FURRING STRIPS VARIES BY BUILDING ELEVATION 3.20 WING WALL END CAP JOINT 3.21 SECOND AND THIRD FLOOR LINE THRU- SHEET NUMBER 3" = 11-0" AT FIBER CEMENT WALL CLADDING 3" = 1'-0" WALL BELLY BAND TRIM TRANSITION AT FIBER CEMENT PLANK LAP CLADDING 3.20 mhg mhg 3.21 NOTES: FORENSIC 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED WALL ASSEMBLIES a e r teRSOLIANIS 2. CAREFULLY REMOVE EXISTING TRIM AND ASSOCIATED FLASHINGS AT AREA TO BE REHABILITATED. 1582nd Drive,Suite 10 3. METAL THRU WALL FLASHING IS TO BE CONTINUOUS AROUND CORNERS AND COMPLETE WITH Gladstone,OR 97027 TEL:503.772.1114 UPTURNED ENDS AT TERMINATIONS, U.O.N. FAX:503.772.4039 4. TRIM TO TUCK UNDER THRU-WALL FLASHING WHERE APPLICABLE. www.forensicbuilding.com 5. PREP AND/OR PRIME TRIM AND CLADDING AS REQUIRED TO RECEIVE PAINT AND SEALANT info@forensicbuilding.com 6. SHEET METAL FLASHING IS TO FULLY COVER SAM FROM ALL UV EXPOSURE.APPLY PRIMER TO COPYRIGHT©2017 FORENSIC BUILDING CONSULTANTS CONCRETE SUBSTRATE PRIOR TO APPLYING SAM. All Rights Reserved OR CCB#155496 WA FORENW C94308 UT#8334529-5501 '`1 �—SCHEDULED WRB, LAP OVER WRB AND THRU-WALL FLASHING BELOW SCHEDULED WRB, LAP OVER WRB f/01) 1 SCHEDULED FIBER CEMENT BATTENS \ AND THRU-WALL FLASHING (BEYOND),ALIGN WITH PANEL JOINTS I BELOW ...loll. AND SPACE TO MATCH EXISTING \ PRINT ALL DETAILS IN CONTINUOUS SEALANT >, CONTINUOUS SEALANT COLOR AT 11x17 \ SCHEDULED FIBER CEMENT PANEL \ SCHEDULED FIBER CEMENT SHINGLE CLIENT CLADDING �. PANEL CLADDING ,.'.111111111111111"°-..401110 1 Association of Unit -440 \ ii 24 GAUGE PRE FINISHED METAL HEAD \ 24 GAUGE PRE FINISHED METAL HEAD Owners of Touchstone FLASHING WITH HEMMED DRIP EDGE FLASHING WITH HEMMED DRIP EDGE Townhomes \ SET IN CONTINUOUS BED OF SEALANT a 0 \ SET IN CONTINUOUS BED OF SEALANT \ ISSUE \4111 , -1111111411 ir/ N i A 06.05.2018 — , 4" —: 4" Construction Issue Set \ N . • REVISIONS ' —�1/2" '� • \ 1/2" REV. DATE .'411111111140 ,' 1„ ', . ----T\� 1., • 1/2" ♦ 1/2" 1111*. s,� SCHEDULED HORIZONTAL FIBER CEMENT TRIM si� SCHEDULED FIBER CEMENT TRIM \ BAND, RABBET BASE FOR INTEGRATION WITH \ ' BAND, RABBET BASE FOR ". PANEL CLADDING BELOW PRIME PRIOR TO INTEGRATION WITH PANEL \ s SEALANT INSTALLATION. s CLADDING BELOW- PRIME PRIOR TO SEALANT INSTALLATION PROJECT NAME N.4000. SEALANT FILLET BEAD Touchstone Townhomes i SEALANT FILLET BEAD 4 Targeted Building \ SCHEDULED PRESSURE TREATED SCHEDULED PRESSURE TREATED Enclosure Rehabilitation /, FURRING STRIP WITH INSECT SCREEN0. �• FURRING STRIP WITH INSECT SCREEN \ ► PROJECT NUMBER \ AT HORIZONTAL TERMINATIONS • AT HORIZONTAL TERMINATIONS (R) 17-091 �; EXISTING SHEATHING EXISTING SHEATHING \ ••i \ f �� :� SHEET NAME ., Will 41111111110 : \ I ;>N NOTE: BELLY BAND LOCATION \ NOTE: BELLY BAND LOCATION WALL • VARIES BY BUILDING ELEVATION 1 P►- : VARIES BY BUILDING ELEVATION DETAILS 3.22 UPPER WALL BELLY BAND TRIM 3.23 UPPER WALL BELLY BAND TRIM SHEET NUMBER 3" = 1'-0" TRANSITION AT FIBER CEMENT PANEL CLADDING 3" = 1'-0" TRANSITION AT FIBER CEMENT PANEL AND SHINGLE PANEL CLADDING 3.22 mhg mhg 3.23 EXAMPLE OF EXISTING OBSERVED FORENSIC CONDITION. PHOTO DOES NOT REPRESENT a"''°'"° `°us°"""" / SCHEDULED WRB, LAP OVER WRB SCOPE OR VARIATIONS OF CONDITIONS 1582nd GlDradstone,OR Suite 10 ' GTEL:503.OR 97027772 Iii AND THRU-WALL FLASHING BELOW i _ FAX 503.772.4039 4" : www.forensicbuilding.com CONTINUOUS SEALANT i nfo@forensicbuilding.com u ' I COPYRIGHT©2017 FORENSIC ; SCHEDULED FIBER CEMENT PLANK LAP • 1/2" '---- BUILDING CONSULTANTS All Rights Reserved CLADDING Wit I 1/2" '- OR CCB#155496 1" ,,� WA FORENW C94308 24 GAUGE PRE FINISHED METAL HEAD . UT#8334529-5501 "h f y ' FLASHING WITH HEMMED DRIP EDGE � SET IN CONTINUOUS BED OF SEALANT LJ1 • alMil. 1 ...,,,...4101111110 4.. SCHEDULED WRB, LAP OVER SAM AND METAL FLASHING BELOW AND SEAL 11111- 11 i x,r • - 1/2" SCHEDULED FIBER CEMENT PLANK LAP CLADDING 1" 1/2" 2 CONTINUOUS BEAD OF SEALANT PRINT ALL DETAILS IN COLOR AT 11x17 . ' ;I• SCHEDULED 10" HORIZONTAL FIBER CEMENT MIN. ) I SCHEDULED PRESSURE TREATED CLIENT TRIM BAND,ALIGN WITH ADJACENT BASE OF '� FURRING STRIP WITH INSECT SCREEN • WALL SOFFIT TRIM AT POP-OUT ELEMENTS- i AT HORIZONTAL TERMINATIONS Association of Unit CONTRACTOR TO VERIFY SIZE CONFIGURATION, Owners of Touchstone PRIME PRIOR TO SEALANT INSTALLATION [i CONTINUOUS BEAD OF SEALANT Townhomes L 24-GAUGE PREFINISHED METAL HEAD ISSUE FLASHING WITH UPTURNED END DAMS AND \ HEMMED RETURN SET IN CONTINUOUS BED 06.0SUE \ 24-GAUGE PRE-FINISHED METAL HEAD 2" OF SEALANT FLASHING WITH HEMMED DRIP EDGE MIN. ConstructionREV. DATE Issue Set HORIZONTAL FIBER CEMENT TRIM BAND, PRIME REVISIONS i SET IN CONTINUOUS BED OF SEALANT PRIOR TO SEALANT INSTALLATION Ompow. IPI 1 ti • fiiiiiro., ..• "-• SCHEDULED 12" HORIZONTAL FIBER CEMENT �:� 24-GAUGE PRE FINISHED METAL HEAD •, TRIM BAND, RABBET BASE FOR INTEGRATION FLASHING WITH UP TURNED FOLDED END 1111(''' .... I N ..• WITH LAPPED CLADDING BELOW-CONTRACTOR DAMS AT METAL FLASHING TERMINATION. TO VERIFY SIZE CONFIGURATION, PRIME PRIORAO 1/2" FLASHING TO FULLY COVER HORIZONTAL • TO SEALANT INSTALLATION eii4•400 s SURFACE OF STONE CAP. ' SCHEDULED PRESSURE TREATED \ ' FURRING STRIP WITH INSECT SCREEN r �� PROJECT NAME AT HORIZONTAL TERMINATIONS CONTINUOUS BEAD OF • SEALANT Touchstone Townhomes • SCHEDULED WRB t• ' _ 4" 5%MIN. Targeted Building EXISTING STONE VENEER SLOPE Enclosure Rehabilitation IIIIII 0111111111111-• CLADDING ASSEMBLY TO 1/2"N.-- REMAIN \ \ PROJECT NUMBER 11111/1.- -41111111111111111111. '440D SEALANT FILLET BEAD .' \1/2" 41111111111 \ EXISTING SHEATHING 1/2" (R) 17-091 SCHEDULED FIBER CEMENT LAPPED TO REMAIN V.I.F. SHEET NAME M CLADDING �. .a � 111111 EXISTING SHEATHING ' EXISTING WRB TO REMAIN WALL DETAILS 3.24 DOUBLE BELLY BAND TRIM 3.25 HORIZONTAL CLADDING TRANSITION SHEET NUMBER 3" = 1'-0" TRANSITION AT FIBER CEMENT PLANK LAP CLADDING 3" = 1'-0" AT FIBER CEMENT PLANK LAP AND STONE VENEER CLADDING 3.24 mhg mhg 3.25 EXAMPLE OF EXISTING OBSERVED NOTE: CONDITION. PHOTO DOES NOT REPRESENT 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS AND SCOPE OR VARIATIONS OF CONDITIONS MAINTAIN ALL RATED WALL ASSEMBLIES ,,:I 2. METAL THRU WALL FLASHING IS TO BE COMPLETE WITH '' UPTURNED ENDS AT TERMINATIONS AND CONTINUOUS AROUND CORNERS. SLOPE HORIZONTAL LEGS TO DRAIN, MIN. 5%. 3. CAREFULLY REMOVE TRIM AND CLADDING AT ELEVATION TO BE REHABILITATED. DO NOT DAMAGE THE EXISTING UNDERLYING WRB. ' 4. NOTIFY CONSULTANT IF EXISTING WRB IS NOT PRESENT OR 0%10 INSUFFICIENT TO TIE INTO. PInik EXISTING SHEATHING L4111`°$' "�� PRESSURE TREATED FURRING STRIP WITH INSECT SCREEN AT HORIZONTAL TERMINATIONS 10111 tSCHEDULED WRB, LAP OVER WRB AND THRU-WALL FLASHING BELOW SCHEDULED FIBER CEMENT PLANK LAP CLADDING Millii 1 If _� )1 CONTINUOUS SEALANT FOR AIR-SEAL 01111 11 minsii1 I — -... - "^ I / 7 f24-GAUGE PRE-FINISHED METAL HEAD FLASHING ‘r—SET ON CONTINUOUS BEAD OF SEALANT WITH UPTURNED END DAMS AT TERMINATIONS SCHEDULED WRB, LAP OVER EXISTING WRB AND CAP FLASHING BELOW SCHEDULED 5/4 x 10"HORIZONTAL FIBER CEMENT TRIM BAND,ALIGN WITH ADJACENT BASE OF WALL SOFFIT TRIM AT POP-OUT ELEMENTS-CONTRACTOR TO VERIFY SIZE CONFIGURATION, PRIME PRIOR TO SEALANT INSTALLATION ___�__ ii 4-~ " t~ + 24-GAUGE PRE-FINISHED METAL HEAD FLASHING EXISTING SOFFIT ' SET ON CONTINUOUS BEAD OF SEALANT WITH CLADDING TO UPTURNED END DAMS AT TERMINATIONS REMAIN SCHEDULED 12"HORIZONTAL FIBER CEMENT FILLET BEAD OF TRIM BAND, CONTRACTOR TO VERIFY SIZE SEALANT CONFIGURATION, PRIME PRIOR TO SEALANT INSTALLATION FIBER CEMENT SOFFIT IIII II CONTINUOUS SEALANT FOR AIR-SEAL WALL CLADDING TO [110 MATCH EXISTING2 2 EXISTING SOFFIT FRAMING MIN. MIN.III III EXISTING WRB TO REMAIN 2„ 2" Mir 0511MIN. MIN. SCHEDULED WRB, LAP OVER EXISTING WRB AND 24-GAUGE FULLY SOLDERED PRE-FINISHED CAP FLASHING BELOW METAL SADDLE FLASHING WITH UP-TURNED III —__----- S .�. 1/2" FOLDED END DAMS AT METAL FLASHING I:* :, IliI '� '1II' •. `�1 TERMINATION. FLASHING TO FULLY COVER -s �I� ��I HORIZONTAL SURFACE OF STONE CAP. I �T .J' CONTINUOUS BEAD OF • ' p ' r 1 SEALANT : 1 EXISTING STONE VENEER \ IF I P• CLADDING ASSEMBLY TO REMAIN EXISTING COLUMN a, FRAMING TO REMAIN EXISTING SHEATHING I; TO REMAIN 1/2" • • '. . EXISTING WRB TO REMAIN 1" 1/2" 3.26 SOFFIT-TO-COLUMN CAP TRANSITION CONDITION 1 3" = V-0" AT FIBER CEMENT TRIM AND STONE VENEER CLADDING mhg = o m jj) O n C/V m _ a) O Q D 73 .- 0) fHH 0 0 CD CO 0 I:nH' onI m -0 r- N ,<n :�7N oC W W ,.m ��rnmm c CO O, aDo orow�om v�/.�, N O n co to N -V J I O cn 7 .0--.cp R. °° -iZ DD "o r-� NOTE: WRB, LAP OVER WRB, SAM AND DRIP 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED WALL ASSEMBLIES �. �: EDGE FLASHING BELOW AND SEAL FORENSIC aaiioiN6 tUNSUNAN is 2. METAL THRU WALL FLASHING IS TO BE COMPLETE WITH UPTURNED ENDS AT TERMINATIONS AND 15 send Drive,site 10 CONTINUOUS AROUND CORNERS. SLOPE HORIZONTAL LEGS TO DRAIN, MIN. 5%. \r..._1_4...______________-------- 1 PRESSURE TREATED FURRING STRIP Gladstone,OR 97027 3. CAREFULLY REMOVE TRIM AND CLADDING AT ELEVATION TO BE REHABILITATED. DO NOT DAMAGE i WITH INSECT SCREEN AT HORIZONTAL TEL 503.772.1114 THE EXISTING UNDERLYING WRB. s TERMINATIONS FAX 503.772 4039 l _____rwww.forensicbuilding.com 4. NOTIFY CONSULTANT IF EXISTING WRB IS NOT PRESENT OR INSUFFICIENT TO TIE INTO. e ; CONTINUOUS SEALANT FOR AIR-SEAL info@forensicbuilding corn COPYRIGHT©2017 FORENSIC EXISTING SHEATHING 2" --� i BUILDING CONSULTANTS 1"` --- 1 I I REFER TO ELEVATION BUMP-OUT All Rights Reserved MIN. ��� LOCATIONS FOR SPECIFIC WOOR CCB#155496 C94308 1 � ` Li' CLADDING TYPES Li 1 UT#8334529-5501 `—�""�'1 24-GAUGE PRE-FINISHED METAL HEAD FLASHING SET ON CONTINUOUS BEAD OF SEALANT WITH i ! '„ UPTURNED END DAMS AT TERMINATIONS N 2,, al 1. f��• CONTINUOUS SEALANT FOR AIR SEAL Z PLYWOOD SOFFIT •. SHEATHING 0 •1►.4' SCHEDULED WRB, LAP OVER WRB, SAM AND FILER CEMENT MIN. ../.....n-1-1-:•....4,1.::1 � 11 Ell: FLASHING BELOW AND SEAL _� SOFFIT PANEL \ ; ,��.' SCHEDULED WRB PRE-STRIPE 0 -4" At‘ SEAL CLADDINt. C r JOINT MIN. «, i...„...---------- ,...*** CHEDULED HORIZONTAL FIBER CEMENT TRIM O /161" BAND, MATCH EXISTING EXPOSURE AND PRINT ALL DETAILS IN 411116110111111111 ''! CONFIGURATION,ALIGN WITH ADJACENT BELLY U COLOR AT 11x17 ti • ?�' TRIM, PRIME PRIOR TO SEALANT INSTALLATION CLIENT Association of Unit a .._ <.. _,._..• __. _._. ti aa�a� s. �= r .' •WTI. 1/2" Owners of Touchstone EXISTING SOFFIT `� 2 - '�NI�N. MAINTAIN MIN. 1/4"GAP BETWEEN SOFFIT Townhomes CLADDING TO = AND TRIM (INCL. FURRING). DO NOT SEAL ISSUE REMAIN 2" :7: MIN. SEALANT 24-GAUGE PRE-FINISHED METAL Q 06.05.2018 FILLET BEAD OF DRIP EDGE FLASHING �/ Q SEALANT \. I 4"SAM I U Construction Issue Set � CL REVISIONS I 1->L SCHEDULED 12"HORIZONTAL FIBER CEMENT Z REv. DATE FIBER CEMENT SOFFIT TRIM BAND, CONTRACTOR TO VERIFY SIZE U WALL CLADDING TO CONFIGURATION, PRIME PRIOR TO SEALANT MATCH EXISTING MIN. MIN. ( INSTALLATION Z O ___.� 'I CONTINUOUS SEALANT FOR AIR-SEAL v~j SCHEDULED WRB, LAP 0'i _ p OVER EXISTING WRB AND 2" 2" EXISTING SOFFIT FRAMING J Z CAP FLASHING BELOW MIN. MIN. EXISTING WRB TO REMAIN Q PROJECT NAME i 1/2" 24-GAUGE FULLY SOLDERED PRE-FINISHED V Touchstone Townhomes 1/2" _ --r-f METAL SADDLE FLASHING WITH UP TURNED O Z Targeted Building FOLDED END DAMS AT METAL FLASHING W Enclosure Rehabilitation ' TERMINATION. FLASHING TO FULLY COVER EXAMPLE OF EXISTING OBSERVED i w•'1111010- -- • I. • ItCONDITION. PHOTO DOES NOT REPRESENT H W HORIZONTAL SURFACE OF STONE CAP. U 7 ,L• l' .' SCOPE OR VARIATIONS OF CONDITIONS• PROJECT NUMBER j; •.'pIiltl �, LL m (R) 17-091 ' CONTINUOUS BEAD OF { , 0 LT ` "1 SEALANT, TYP. \ .. - it ;b \ Q SHEET NAME •° • EXISTING STONE VENEER I 1 WALL I •• • CLADDING ASSEMBLY TOj DETAILS EXISTING COLUMN r ' N. REMAIN 'v b FRAMING TO REMAIN t EXISTING SHEATHING '.. • C� 3 TO REMAIN SHEET NUMBER CV II , li ' \ _ f� CoCOM 1 / t,. EXISTING WRB TO REMAIN \ 3.27 NOTES: EXAMPLE OF EXISTING OBSERVED FORENSIC 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED WALL ASSEMBLIES CONDITION. PHOTO DOES NOT REPRESENT B B;i B I B 6 L CM 5 B C<.,1 C 2. CAREFULLY REMOVE EXISTING TRIM, SIDING, WRB AND ASSOCIATED FLASHINGS AT ELEVATION TO BE REHABILITATED. SCOPE OR VARIATIONS OF CONDITIONS 1582nd Drive,Suite 10 3. TRIM TO TUCK UNDER THRU-WALL FLASHING WHERE APPLICABLE. Gladstone,OR 97027 4. PREP TRIM AND CLADDING AS REQUIRED TO RECEIVE PAINT. TEL 503.772.1114 . `: FAX 503.772.4039 5. RUN METAL FLASHING THROUGH ALL EXTERIOR CORNER TRIM. www.forensicbuilding.com �„ „; ; info@forensicbuilding corn WRB, LAP OVER WRB, SAM AND DRIP I COPYRIGHT©2017FORENSIC �� I �'I EDGE FLASHING BELOW AND SEALh_____ BUILDING CONSULTANTS All Rights Reserved SCHEDULED FIBER CEMENT BATTENS A, OR CCB#155496 ' (BEYOND),ALIGN WITH PANEL JOINTS wAFORENwcsa3os UT#8334529-5501 I AND SPACE TO MATCH EXISTING -..411.1111111-----: 11111.-2" •II CONTINUOUS SEALANT FOR AIR-SEAL EXISTING SHEATHING "– MIN. � � I � PRESSURE TREATED FURRING STRIP I w....„ ... I 2„ i WITH INSECT SCREEN AT HORIZONTAL "'�' C , �= MIN. TERMINATION • S firwiclimwr, Awilei IN ���� - �q�. FIBER CEMENT PANEL CLADDING I 4" i 24 GAUGE PRE FINISHED METAL HEAD FLASHING SET ON CONTINUOUS BEAD OF SEALANT WITH i`a; t UPTURNED END DAMS AT TERMINATIONS • 1/2 `LY , OOD S'oF' , I 1" PRINT ALL DETAILS IN CONTINUOUS SEALANT FOR AIR-SEAL HEATHING till� ,118 ; 1/2" COLOR AT 11x17 2� WRB, LAP OVER WRB, SAM AND DRIP CLIENT FIBERCEIv�ENT MIN. EDGE FLASHING BELOW AND SEAL L' SOFFI P'NEL I � rlMf Association of Unit SEAL CLADD ` 2„ I OP!IIl SCHEDULED WRB PRE-STRIPE Owners of Touchstone JOINT SCHEDULED FIBER CEMENT TRIM, MATCH • MIN. �,,; EXISTING EXPOSURE AND CONFIGURATION Townhomes !w� ISSUE 24-GAUGE PRE-FINISHED METAL �� k. '! DRIP EDGE FLASHINGill 5" 06.05.2018 a- Mill I . . ::., r.;.....: /2 Construction Issue Set MIN.111 1 s MAINTAIN MIN. 1/4"GAP BETWEEN SOFFIT • I. REVISIONS �� AND TRIM (INCL. FURRING). DO NOT SEAL REV. DATE 2 ' SCHEDULED FIBER CEMENT MIN. I TRIM- PRIME PRIOR TO SEALANT 111. III 1SEALANT INSTALLATION, (TYP.) 1111 I 4"SAM il. I 1 4 FILLET BEAD OF SEALANT, TYPICAL PROJECT NAME ah 6 SEALANT SCHEDULED FIBER CEMENT LAP CLADDING Targeted Building EXISTING SHEATHING Touchstone Townhomes Enclosure Rehabilitation • I SCHEDULED WRB PROJECT NUMBER (R) 17-091 0i SCHEDULED FURRING STRIPS WITH INSECT SCREENS AT SHEET NAME ►_ TERMINATIONS, TYP. WALL ME ............. DETAILS 3.28 SOFFIT TRANSITION DETAIL SHEET NUMBER 3" = 11-0" AT FIBER CEMENT PANEL CLADDING AND PLANK LAP CLADDING 3.28 mhg 3.00 Wall Details-Touchstone Townhomes.dwg NOTES: FORENSIC 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED WALL ASSEMBLIES BUILOIIG IOWITANIS 2. CAREFULLY REMOVE EXISTING TRIM, SIDING, WRB AND ASSOCIATED FLASHINGS AT ELEVATION TO BE REHABILITATED. 15 send Drive,Suite 10 3. TRIM TO TUCK UNDER THRU-WALL FLASHING WHERE APPLICABLE. Gladstone,OR 97027 4. PREP TRIM AND CLADDING AS REQUIRED TO RECEIVE PAINT. TEL 503.772 1114 FAX:503.772.4039 5. RUN METAL FLASHING THROUGH ALL EXTERIOR CORNER TRIM. www.forensicbuilding.com A info@forensicbuilding.corn , WRB, LAP OVER WRB, SAM AND DRIP COPYRIGHT©2017 FORENSIC V I 1 I t,t EDGE FLASHING BELOW AND SEAL BUILDING CONSULTANTS , d F All Rights Reserved PRESSURE TREATED FURRING STRIP WAFORENWC94308 � I OR CCB#155496 WITH INSECT SCREEN AT HORIZONTAL UT#8334529-5501 -------- �= I il TERMINATIONS 2" EXISTING SHEATHING /" MIN. 1 it NMI -CONTINUOUS SEALANT FOR AIR-SEAL 2" • —7 AIM __ MIN. SCHEDULED FIBER CEMENT SHINGLE PANEL .-.- CLADDING (SIM AT PLANK LAP CLADDING) _ _ 4" l ' --- w.• 24 GAUGE PRE FINISHED METAL HEAD FLASHING WRB SET ON CONTINUOUS BEAD OF SEALANT WITH 1/2" UPTURNED END DAMS AT TERMINATIONS LY . OOD SOF 'IT 1:% CONTINUOUS SEALANT FOR AIR-SEAL 1" PRINT ALL DETAILS IN .HEATHING ' ,1!i' • '1� COLOR AT 11x17 FIBER CEMENTIII 2 ,.,..,i% WRB, LAP OVER WRB, SAM AND DRIP 1/2 MIN. ✓ EDGE FLASHING BELOW AND SEAL CLIENT SOFFIT PANEL ...• Association of Unit SEAL CLADD • f SCHEDULED WRB PRE-STRIPE C JOINT 2 s .' SCHEDULED FIBER CEMENT TRIM, MATCH • Owners of Touchstone Townhomes MIN. ,�,,;�� EXISTING EXPOSURE AND CONFIGURATION 0.0 1 1 w� ISSUE '� a� 24-GAUGE PRE-FINISHED METAL 06.05.2018 ��.,, ` e �"' • DRIP EDGE FLASHING 5" mid2„ ••... • ..:-,:.:;.Y t . s 1/2" Construction Issue Set MIN.1111 • REVISIONS MAINTAIN MIN. 1/4"GAP BETWEEN SOFFIT • L '� AND TRIM (INCL. FURRING). DO NOT SEAL REV, DATE ---_ 2 SCHEDULED FIBER CEMENT MIN. TRIM- PRIME PRIOR TO SEALANT 0 ii 1 SEALANT INSTALLATION, (TYP.) _ __ — _ Sift ..1. FILLET BEAD OF SEALANT, TYPICAL PROJECT NAME 4"SAM Touchstone Townhomes 0111°.- SCHEDULED FIBER CEMENT LAP CLADDING Targeted Building EXISTING SHEATHING Enclosure Rehabilitation • oil SCHEDULED WRB PROJECT NUMBER (R) 17-091 0 g SCHEDULED FURRING STRIPS WITH INSECT SCREENS AT SHEET NAME TERMINATIONS, TYP. WALL DETAILS 3.29 SOFFIT TRANSITION DETAIL SHEET NUMBER 3" = 1'-0" AT FIBER CEMENT SHINGLE PANEL CLADDING AND PLANK LAP CLADDING 3,29 mhg 3.00 Wall Details-Touchstone Townhomes.dwg NOTES: FORENSIC 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED WALL ASSEMBLIES ,„, Y 6 r o„®„AN„ 2. CAREFULLY REMOVE EXISTING TRIM, SIDING, WRB AND ASSOCIATED FLASHINGS AT ELEVATION TO BE REHABILITATED. 1582nd Drive,Suite 10 3. TRIM TO TUCK UNDER THRU-WALL FLASHING WHERE APPLICABLE. Gladstone,OR 97027 4. PREP TRIM AND CLADDING AS REQUIRED TO RECEIVE PAINT. TEL 503.772.1114 FAX:501772.4039 5. RUN METAL FLASHING THROUGH ALL EXTERIOR CORNER TRIM. www.forensicbuilding.com info@forensicbu ilding.com COPYRIGHT©2017 FORENSIC BUILDING CONSULTANTS All Rights Reserved OR CCB#155496 PRESSURE TREATED FURRING STRIP WITH INSECT WA FORENW C94308 UT#8334529-5501 .r `� "` iri SCREEN AT HORIZONTAL TERMINATIONS"'AO. It SCHEDULED WRB, LAP OVER WRB AND THRU-WALL FLASHING BELOW . 4111111110 CONTINUOUS SEALANT FOR AIR-SEAL 11 . 0111111111111-11111111 1 SCHEDULED FIBER CEMENT SHINGLE PANEL JIi CLADDING (SIM AT PLANK LAP CLADDING) nor -/ _ I �� PRINT ALL DETAILS IN 1 COLOR AT 11x17 N. 4" CLIENT 24-GAUGE PRE-FINISHED METAL HEAD FLASHING1 A A ., Association of Unit WITH HEMMED DRIP EDGE SET IN CONTINUOUS BED 1/2" Owners of Touchstone OF SEALANT,ALIGN WITH THRU-WALL POP-OUT \ SOFFIT FLASHING Townhomes —TN- 1" WRB, LAP OVER WRB, SAM AND DRIP EDGE ISSUE 06.05.2018 Construction Issue Set FLASHING BELOW AND SEAL 1/2 i SCHEDULED FIBER CEMENT TRIM BAND, RABBET BASE FOR INTEGRATION WITH PLANK LAP ` REVISIONS CLADDING BELOW- PRIME PRIOR TO SEALANT REv. DATE INSTALLATION • i _ _ 5� _ .1: 'r"+• ♦.. • •1........ Iw'.:• . i .• '—ai EALANT FILLET BEAD EXISTING SOFFIT MIN. ill, — CLADDING TO CONTINUOUS SEALANT FOR AIR-SEAL REMAIN 2" SCHEDULED FIBER CEMENT PLANK LAP CLADDING PROJECT NAME MIN. ... 24-GAUGE PRE-FINISHED METAL HEAD FLASHING Touchstone Townhomes ,1006001...000.. , 1SET IN CONTINUOUS BED OF SEALANT Targeted Building SAM Enclosure Rehabilitation •• -••NO'•• :••• L `: SCHEDULED FIBER CEMENT TRIM PROJECT NUMBER �1/2" (R) 17-091 24-GAUGE PRE-FINISHED METAL DRIP EDGE FLASHING SHEET NAME SEALANT WALL DETAILS 3.30 DOOR ALCOVE SOFFIT TRANSITION DETAIL SHEET NUMBER 3" = 1'-0" AT FIBER CEMENT SHINGLE PANEL/PLANK LAP CLADDING AND TRIM 3.30 mhg 3.00 Wall Details-Touchstone Townhomes.dwg NOTES: EXAMPLE OF EXISTING OBSERVED FORENSIC 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED WALL ASSEMBLIES CONDITION. PHOTO DOES NOT REPRESENT e u? lEOPSWANIS 2. CAREFULLY REMOVE EXISTING TRIM, SIDING, WRB AND ASSOCIATED FLASHINGS AT ELEVATION TO BE REHABILITATED. SCOPE OR VARIATIONS OF CONDITIONS 1582nd Drive,Suite 10 3. TRIM TO TUCK UNDER THRU-WALL FLASHING WHERE APPLICABLE. ! " I Gladstone,OR 97027 4. PREP TRIM AND CLADDING AS REQUIRED TO RECEIVE PAINT. TEL 503.7721114 FAX'503.772.4039 5. RUN METAL FLASHING THROUGH ALL EXTERIOR CORNER TRIM. www.forensicbuilding.corn WRB, LAP OVER WRB, SAM AND DRIP nfo@forensicbuilding.com [v. " EDGE FLASHING BELOW AND SEAL I' COPYRIGHT©2017 FORENSIC BUILDING CONSULTANTS All Rights Reserved I i PRESSURE TREATED FURRING STRIP -- OR CCB#155496 ir.s.4,..........---- WITH INSECT SCREEN AT HORIZONTAL ® WA FORENW 094308 TERMINATIONS - UT#8334529-5501 EXISTING SHEATHINGt� /7-1--1 CONTINUOUS SEALANT FOR AIR-SEAL 2•• I „ .MIN.'" I li REFER TO ELEVATION BUMP-OUT k LOCATIONS FOR SPECIFIC . ���In...��. �v �I CLADDING TYPES—�,_ --' -., 24-GAUGE PRE-FINISHED METAL HEAD FLASHING SET ON CONTINUOUS BEAD OF SEALANT WITH if n UPTURNED END DAMS AT TERMINATIONS RB r 'r's;� 4,. 416, ,... -, L OOD SO'FIT I ..., f� CONTINUOUS SEALANT FOR AIR-SEAL � PRINT ALL DETAILS IN HING •'k" ' SCHEDULED WRB, LAP OVER WRB, SAM AND --� 1/2" COLOR AT 11x17 2 a•• DRIP EDGE FLASHING BELOW AND SEAL — CLIENT CEMENT MIN. ' " 1" .. . A TPANEL I� • or' �j•: SCHEDULED WRB PRE-STRIPE �� Association of Unit IN� 1/2" Owners of Touchstone • MIN. I ,• ;„,.../..---- .....'" SCHEDULED HORIZONTAL FIBER CEMENT TRIM Ts of ouch .� BAND, MATCH EXISTING EXPOSURE AND •N CONFIGURATION, ALIGN WITH ADJACENT BELLY mes ISSUE • �• TRIM, PRIME PRIOR TO SEALANT INSTALLATION .w 06.05.2018 :ti. Construction Issue Set 4 5" REVISIONS '�: MIN.ril MAINTAIN MIN. 1/4"GAP BETWEEN SOFFIT REV. DATE • AND TRIM (INCL. FURRING). DO NOT SEAL — EXISTING 2" 24-GAUGE PRE-FINISHED METAL SOFFIT A 4"SAM SEALANT CLADDING "' MIN. DRIP EDGE FLASHING _ TO REMAIN "!k SCHEDULED 12" HORIZONTAL FIBER CEMENT --- -- yy TRIM BAND, CONTRACTOR TO VERIFY SIZE CONFIGURATION, PRIME PRIOR TO SEALANT __ ;1A, 2" INSTALLATION — '• ,' MINIlli ' El PROJECT NAME SCHEDULED WRB, LAP OVER SAM AND THRU- 1 WALL SOFFIT DRIP FLASHING BELOW AND SEAL 'Zf MIN. •w To Targeone ted o n homes _ SCHEDULED PRESSURE TREATED 9 g II t�, FURRING STRIPS WITH INSECT Enclosure Rehabilitation :V. 11111111110- SCREENS AT TERMINATIONS, TYP. •• �� V PROJECT NUMBER • or ; r Attie!'t-•• '• -gip, i 1/2" (R) 17-091 24-GAUGE PRE-FINISHED METAL SHEET NAME EXISTING SOFFIT DRIP EDGE FLASHING WALL CLADDING TO REMAIN DETAILS 3.31 RECESSED GARAGE SOFFIT TRANSITION DETAIL SHEET NUMBER 3" = 1'-0" AT FIBER CEMENT SHINGLE PANEL/ PANEL CLADDING AND DOUBLE TRIM 3,31 mhg 3.00 Wall Details-Touchstone Townhomes.dwg NOTES: FORENSIC 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED WALL ASSEMBLIES ,BUILDING t I A N 1 i 2. CAREFULLY REMOVE EXISTING TRIM, SIDING, WRB AND ASSOCIATED FLASHINGS AT ELEVATION TO BE REHABILITATED. 15 82nd Drive,Suite 10 3. TRIM TO TUCK UNDER THRU-WALL FLASHING WHERE APPLICABLE. Gladstone,OR 97027 4. PREP TRIM AND CLADDING AS REQUIRED TO RECEIVE PAINT. TEL 503.772.1114 FAX:503.772.4039 5. RUN METAL FLASHING THROUGH ALL EXTERIOR CORNER TRIM. www.forensicbuilding.com info@forensicbuilding corn COPYRIGHT©2017 FORENSIC UILDING CONSULTANTS °V SCHEDULED WRB, LAP OVER WRB B 01100, i ' IV AND THRU-WALL FLASHING BELOW All Rights Reserved f 1ill 1OR CCB#155498 CONTINUOUS SEALANT WA FORENW C94308 ii -41111111011C ' UT#8334529-5501 �, i{ f SCHEDULED FIBER CEMENT PLANK LAP CLADDING ' 11111111.-A' _ I' 24 GAUGE PRE FINISHED METAL HEAD FLASHING WITH HEMMED DRIP EDGE L /............_./ „__......_z SET IN CONTINUOUS BED OF SEALANT r M / _ A ilt \ , • N PRINT ALL DETAILS IN COLOR AT 11x17 CLIENT r Association of Unit Owners of Touchstone SCHEDULED 5/4 x 10” HORIZONTAL FIBER Townhomes > CEMENT TRIM BAND, ALIGN WITH ADJACENT BASE OF WALL SOFFIT TRIM AT POP OUT ISSUE ELEMENTS- CONTRACTOR TO VERIFY SIZE 4" 06.05.2018 1 '� CONFIGURATION, PRIME PRIOR TO SEALANT J_ �1 —/ / - ` INSTALLATION 1/2" Construction Issue Set "1.4 1" REVISIONS %f I - ' `�„� s• REV. DATE V24-GAUGE PRE-FINISHED METAL HEAD 1/2" \ FLASHING WITH HEMMED DRIP EDGE Vii, ,•• SET IN CONTINUOUS BED OF SEALANT EXISTING SOFFIT :IN ,-- CLADDING —CLADDING TO REMAIN " ..• :w SCHEDULED 5/4 x 12"HORIZONTAL FIBER CEMENT TRIM BAND, RABBET BASE FOR INTEGRATION .,�1.'`� WITH LAPPED CLADDING BELOW-CONTRACTOR � TO VERIFY SIZE CONFIGURATION, PRIME PRIOR PROJECT NAME TO SEALANT INSTALLATION . Touchstone Townhomes Z.i 1°'` SCHEDULED PRESSURE TREATED• Targeted Building • .i l ,• FURRING STRIP WITH INSECT SCREEN Enclosure Rehabilitation .t.. —�` - AT HORIZONTAL TERMINATIONS PROJECT NUMBER SCHEDULED WRB, LAP OVER SAM AND THRU • - •• WALL SOFFIT DRIP FLASHING BELOW AND SEAL (R) •''•*t" _.. • �' •••.•... •14 R 17 091 ,a: vi i �1/2„ SHEET NAME 24-GAUGE PRE-FINISHED METAL 5 WALL SEALANT FILLET BEAD DRIP EDGE FLASHING DETAILS 3.32 SOFFIT TRANSITION DETAIL , SHEET NUMBER 3" = 1'-0" AT FIBER CEMENT PLANK LAP CLADDING AND DOUBLE TRIM �.�� mhg 3.00 Wall Details-Touchstone Townhomes.dwg FORENSIC BUILDING CGGSOIIANIS 15 82nd Drive,Suite 10 Gladstone,OR 97027 TEL:503.772.1114 FAX:503 772.4039 www.forensicbuildingcorn info@forensicbuilding.com COPYRIGHT©2017 FORENSIC BUILDING CONSULTANTS EXISTING SHEATHING All Rights Reserved a.OR CCB#155496 ; y.4 t WA FORENW C94308 UT#8334529-5501 I �•0 f WRB, LAP OVER WRB AND SAM I g BELOW AND SEAL \ A 100. ...00lIll. 11 1 . PRESSURE TREATED FURRING 4" /... STRIPS WITH INSECT SCREENS j*11111 1 AT TERMINATIONS 1/2 SEALANT ` 1/2" ®1. FIBER CEMENT CLADDING PRINT ALL DETAILS IN ` 24-GAUGE PRE FINISHED METAL HEAD COLOR AT 11x17 s. FLASHING SET ON BEAD OF SEALANT. FILL CLIENT VOIDS AT EDGESWITH SEALANT 86 Association of Unit SAM TO LAP OVER HEAD FLANGE ... Owners of Touchstone T. 5.6' Bu.+ Townhomes ; """` _ `f EXTEND 1/2" PRESSURE TREATED ISSUE ,, t FURRING BEHIND TRIM o 0 '4111 • DYNAMIC SEALANT JOINT 06.05.2018 1.• ' /2" Construction Issue Set . I PRE-MANUFACTURED VENT HOOD 7.a" REVISIONS WITH INTEGRAL FLANGES BY PRIMEX- PROVIDE SAME OR GREATER FREE REV. DATE VENT AREA AS EXISTING 0 0 NOTE: UPON DEMOLITION, CONTRACTOR TO 4.8 VERIFY THAT EXISTING DUCTWORK IS NOMINAL 4"MINIMUM DIAMETER, TYP. • +:, INTEGRAL DRIP EDGE PROJECT NAME .f4 * IIII \ PROVIDE SAME OR GREATER FREE VENT Touchstone Townhomes SEALANT AREA AS EXISTING Targeted Building 9" Enclosure Rehabilitation 5/4 FIBER CEMENT TRIM BLOCK, PRIME PRIOR TO SEALANT INSTALLATION, (TYP.) PROJECT NUMBER B,• ,,:i 9"SAM NOTES: (R) 17-091 STATIC FILLET JOINT(TYP.) 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED WALL ASSEMBLIES :::$01111111.1111P- 2. ENSURE THAT SAM IS FULLY COVERED FROM ALL UV EXPOSURE 111 3. SEAL DUCT-TO-HOOD STEM WITH CODE COMPLIANT AND COMPATIBLE MASTIC SEALANT. SHEET NAME PRESSURE TREATED FURRING STRIPS WITH 4. INSTALL LOW EXPANDING FOAM AROUND ALL PENETRATIONS TO LIMIT AIR LEAKAGE. WALL 5. IF PENETRATION DOES NOT FALL ALONG FRAMING, INSTALL STRAPPING OR BLOCKING AND DETAILS INSECT SCREENS AT TERMINATIONS INTERMEDIATE FURRING STRIPS AS NEEDED FOR BLOCK AND SIDING TERMINATIONS. 6. PROVIDE EXTENSIONS WHERE NEEDED TO PIPES, DUCTS,AND OTHER PENETRATIONS TO 3.33 EXHAUST VENT PENETRATION ACCOMMODATE INCREASED THICKNESS OF WALL ASSEMBLIES. SHEET NUMBER 7. ENSURE AIR TIGHT DUCT LINES AT VENTS. 3" = 1'-0" TYPICAL MOUNTING BLOCK AT FIBER CEMENT CLADDING 3.31 mhg NOTES: FORENSIC 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED WALL ASSEMBLIES BUILDING r O N,„,,R N,S 2. ENSURE THAT.SAM IS FULLY COVERED FROM ALL UV EXPOSURE 3. SEAL DUCT-TO-HOOD STEM WITH CODE COMPLIANT AND COMPATIBLE MASTIC SEALANT. lGl82nd ds oDrive, e,OSuite 97027 4. INSTALL LOW EXPANDING FOAM AROUND ALL PENETRATIONS TO LIMIT AIR LEAKAGE. 14 FAX 50TEL:503.772.11 3.772.40399 5. IF PENETRATION DOES NOT FALL ALONG FRAMING, INSTALL STRAPPING OR BLOCKING AND www.forensicbuilding.com INTERMEDIATE FURRING STRIPS AS NEEDED FOR BLOCK AND SIDING TERMINATIONS. nfo@forensicbuilding.com 6. PROVIDE EXTENSIONS WHERE NEEDED TO PIPES, DUCTS,AND OTHER PENETRATIONS TO COPYRIGHT©2017 FORENSIC BUILDING CONSULTANTS ACCOMMODATE INCREASED THICKNESS OF WALL ASSEMBLIES. All Rights Reserved 7. AT DYNAMIC SEALANT JOINTS, MAINTAIN JOINT DEPTH AT ONE HALF JOINT WIDTH. OR CCB#155496 ENSURE AIR TIGHT DUCT LINES AT VENTS. 8. WA FORENW C94308 UT#8334529-5501 ENSURE ADEQUATE BLOCKING EXISTS, PROVIDE BLOCKING AS NEEDED INSTALL UPPER COURSE OF SCHEDULED O. 1 PREFINISHED METAL WRB HEAD FLASHING PRINT ALL DETAILS IN ENSURE ADEQUATE COLOR AT 11x17 I WITH END DAMS CLEARANCE CLIENT INSTALL LOWER ; AND HEMMED DRIP INSTALL SEALANT AT COURSE OF EDGE SET IN END DAMS Association of Unit SCHEDULED CONTINUOUS BED Owners of Touchstone WRB OF SEALANT Townhomes EXTEND PENETRATION 0 ISSUE INSTALL SAM el i$ PROVISIONS AS06.05.2018 WRAP-APPLY INill I NECESSARYA WEATHERLAP I ,11 l � � Construction Issue Set 1 INSTALL 1/2 DYNAMIC FASHION AND INSTALL CONT. SEALANT JOINT AT REVISIONS INCLUDE SEALANT AT INSTALL 5/4 PENETRATION REV. DATE PATCHES AT ALL WRB LAP FOR MOUNTING BLOCK, CORNER VOIDS �� AIR SEAL WEATHER CUT ABUTTING JOINTS 11 IF 2-PIECE INSTALL FILLET BEAD ASSEMBLY OF SEALANT AT REQUIRED SIDES AND BASE OF III,` MOUNTING BLOCK INSTALL SCHEDULED SCHEDULED FIBER PROJECT NAME PRESSURE TREATED CEMENT LAPPED FURRING STRIPS WITH CLADDING Touchstone Townhomes INSECT SCREENS AT Targeted Building TERMINATIONS Enclosure Rehabilitation STEP 1 STEP 2 STEP 3 STEP 4 PROJECT NUMBER (R) 17-091 SHEET NAME WALL DETAILS 3.34 TYPICAL MOUNTING BLOCK ADJUST VENT PENETRATION LOCATION AS NECESSARY SHEET NUMBER WERE HOOD ASSEMBLY ENCROACHES ON TRIM. LOCATE 1" = 11-0" AT FIBER CEMENT SIDING - ISOMETRIC SEQUENCE VENT ASSEMBLY SO AS FLASHING AND SEALANT ARE 3. mhg INSTALLED WITHIN FIBER CEMENT LAP SIDING AREA. 4 SEE DETAIL 3.33 FOR ADDITIONAL ASSEMBLY INFORMATION FORENSIC B41l BING GONSIIiIAN13 15 82nd Drive,Suite 10 Gladstone,OR 97027 TEL:503.772.1114 FAX 503 772.4039 www.fo re n s i c b u i l d i n g.corn info@forensicbuilding.com COPYRIGHT©2017 FORENSIC BUT EXISTING SHEATHING All Rights CONSULTANTS RghtsR served e. OR WA FORENWCCB#155496 08 C943 ' 41111° 4 UT#8334529-5501 SCHEDULED WRB, LAP OVER WRB " AND SAM BELOW AND SEAL • :.....01%. 5 4111 • SCHEDULED PRESSURE TREATED FURRING STRIP WITH INSECT SCREEN ; AT HORIZONTAL TERMINATIONS ... " 111 ` CONTINUOUS SEALANT 1/2,, 1/2" 411 SCHEDULED FIBER CEMENT PLANK 1/2° _woIt LAP CLADDING I PRINT ALL DETAILS IN [1 24-GAUGE PRE-FINISHED METAL HEAD COLOR AT 11x17 n. "::_ L FLASHING SET ON BEAD OF SEALANT. CLIENT FILL VOIDS AT EDGES WITH SEALANT Association of Unit ''' SAM TO LAP OVER HEAD FLANGE Owners of Touchstone s. Townhomes �-. 5.6 ®I : _% EXTEND 1/2" PRESSURE TREATED • , FURRING BEHIND TRIM 0 0 ISSUE ` I DYNAMIC SEALANT JOINT ,.__,�, 06.05.2018 ,!•: ,., s f, dll 1 . /2" bill' Construction Issue Set PRE-MANUFACTURED VENT HOOD ,• 1 11111110 7.a" REVISIONS WITH INTEGRAL FLANGES BY PRIMEX- . PROVIDE SAME OR GREATER FREE ' REV. DnrE VENT AREA AS EXISTING �-1 L-, . 0 0 NOTE: UPON DEMOLITION, CONTRACTOR TO a.e° ✓ VERIFY THAT EXISTING DUCTWORK IS I NOMINAL 4" MINIMUM DIAMETER, TYP. INTEGRAL DRIP EDGE PROJECT NAME °•� PROVIDE SAME OR ' SEALANT GREATER FREE VENT Touchstone Townhomes g ► i ! SCHEDULED 5/4 HORIZONTAL FIBER CEMENT AREA AS EXISTING Targeted Building TRIM BAND, RABBET BASE FOR INTEGRATION Enclosure Rehabilitation . WITH LAPPED CLADDING BELOW PRIME PRIOR ., PROJECT NUMBER TO SEALANT INSTALLATION r SNOTES:4 ..4111111111LW (R) 17-091 1 STATIC SEALANT FILLET JOINT(TYP.) 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED WALL ASSEMBLIES 2. ENSURE THAT SAM IS FULLY COVERED FROM ALL UV EXPOSURE • 9" SAM 3. SEAL DUCT-TO-HOOD STEM WITH CODE COMPLIANT AND COMPATIBLE MASTIC SEALANT. SHEET NAME E. SCHEDULED PRESSURE TREATED 4. INSTALL LOW EXPANDING FOAM AROUND ALL PENETRATIONS TO LIMIT AIR LEAKAGE. WALL 5. IF PENETRATION DOES NOT FALL ALONG FRAMING, INSTALL STRAPPING OR BLOCKING AND FURRING STRIP WITH INSECT SCREEN DETAILS AT HORIZONTAL TERMINATIONS INTERMEDIATE FURRING STRIPS AS NEEDED FOR BLOCK AND SIDING TERMINATIONS. 6. PROVIDE EXTENSIONS WHERE NEEDED TO PIPES, DUCTS, AND OTHER PENETRATIONS TO .- 3.35 EXHAUST VENT PENETRATION ACCOMMODATE INCREASED THICKNESS OF WALL ASSEMBLIES. SHEET NUMBER 7. ENSURE AIR TIGHT DUCT LINES AT VENTS. 3" = 11-0" AT BELLY BAND TRIM WITH FIBER CEMENT LAPPED CLADDING 3.35 mhg NOTES: FORENSIC 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED WALL ASSEMBLIES. BUILDING _O N:N S<m N,S 2. SHEET METAL FLASHING IS TO FULLY COVER SAM FROM ALL UV EXPOSURE. 1582nd Drive,Suite 10 3. SAM TO EXTEND OVER SIDES OF ELECTRICAL UTILITY BOXES. Gladstone,OR 97027 TEL 503.772 1114 4. FORENSIC RECOMMENDS DATA CABLE INSTALLATION/INTEGRATION AS DETAILED TO MAINTAIN BUILDING ENVELOPE INTEGRITY. \ FAX 503 772.4039 5. FASTENER FOR DATA CABLE POSITIONED WITHIN THE BOTTOM INCH (1") OF PLANK AT LAP AND NOT TO PENETRATE WRB www.forensicbuilding.corn 6. INSTALL LOW EXPANDING FOAM AROUND ALL PENETRATIONS TO LIMIT AIR LEAKAGE. nto@forensicbuilding.00m 7. IF PENETRATION DOES NOT FALL ALONG FRAMING, INSTALL STRAPPING OR BLOCKING AND INTERMEDIATE FURRING STRIPS AS COPYRIGHT G CON 7 FORENSIC 4" BUILDING CONSULTANTS NEEDED FOR BLOCK AND SIDING TERMINATIONS. All Rights Reserved 8. PROVIDE EXTENSIONS WHERE NEEDED TO WIRING, PIPES, DUCTS, AND OTHER PENETRATIONS TO ACCOMMODATE INCREASED OR CCB#155496 THICKNESS OF WALL ASSEMBLIES. ♦ 1/2" WA FORENW C94308 UT#8334529-5501 9. ANGLE CABLE PENETRATION THROUGH MOUNTING BLOCK FROM BELOW. J 1/2" X1/2" EXISTING SHEATHING EXISTING SHEATHING 741'11. SCHEDULED WRB, LAP OVER WRB ANDSCHEDULED WRB, LAP OVER SAM FLASHING40111111.-11: SAM BELOW AND SEAL liwimilio...-'40111111411. ��' BELOW AND SEAL01111111._.,41111111. SCHEDULED PRESSURE TREATEDFURRINGSCHEDULED PRESSURE TREATED FURRING iSCHEDU EDRIRS SUH INSECTSTRIPS WITH INSECT SCREENS AT SCREENS AT TERMINATIONS l TERMINATIONSPRINT ALL DETAILS IN SCHEDULED FIBER CEMENT PLANK LAP COLORAT11x17CLADDING SCHEDULED FIBER CEMENT PLANK LAP CLIENT 24-GAUGE PRE-FINISHED METAL HEAD CLADDING - - -IIIIIIIIIIIIIe FLASHING SET ON BEAD OF SEALANT. Association of Unit FILL VOIDS AT EDGES WITH SEALANT Owners of Touchstone 41ftle' "._' "-_,,,. 24-GAUGE PRE-FINISHED METAL HEAD Townhomes Wir CONTINUOUS SEALANT FLASHING SET ON BEAD OF SEALANT. "11140 I FILL VOIDS AT EDGES WITH SEALANT ISSUE I ` 5/4 x 10"x 10" FIBER CEMENT TRIM 3" II QUICKFLASH PANEL TRANSITION TO J-BOX 06.05.2018 � ' BLOCK, PRIME PRIOR TO SEALANT ! INSTALLATION, (TYP.) SET HEIGHT PER , u '� Construction Issue Set _4.08,0. a, OWNER'S REQUIREMENTS. ELECTRICAL/UTILITY BOX „ 'y MINIMALLY EXPANDING FOAM REVISIONS � = QUICKFLASH PANEL � I REv. DATE.... SEALANT AT BACK OF BOX "011iiiiiiii '� INSTALLED DATA CABLE AND SEAL WRB, EXTEND BEHIND ELECTRICAL BOX 1111111111111111 Il INI SOLID BLOCKING SEALANT FOR II\01110 ' AIR SEAL 4.. ll 1 I - , 1/2" DYNAMIC SEALANT JOINT(TYP.) --44‘41) 11111. \ 144 PROJECT NAME 1/2" 5/4 FIBER CEMENT TRIM BLOCK, PRIME r '411/111114, \ 1/2" liftballiNovo._11 PRIOR TO SEALANT INSTALLATION, (TYP.) Touchstone Townhomes Targeted Building 1/2" SEALANT FOR AIR SEAL Enclosure Rehabilitation Ompo.._ STATIC FILLET JOINT(TYP.) STATIC FILLET JOINT(TYP.)„aloePROJECT NUMBER �' (R) 17 091 SCHEDULED WRBillil ` i SHEET NAME WALL DETAILS 3.36 UTILITY MOUNTING BLOCK WITH 3.37 SURFACE MOUNTED ELECTRICAL SHEET NUMBER 3” = 1'-0" PROPER DATA CABLE PENETRATION AT FIBER CEMENT CLADDING 3" = 1'-0" BOX AT FIBER CEMENT CLADDING 3.36 mhg mhg 3.37 EXAMPLE OF EXISTING OBSERVED NOTES: EXAMPLE OF EXISTING OBSERVED FORENSIC CONDITION. PHOTO DOES NOT REPRESENT 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED WALL ASSEMBLIES CONDITION. PHOTO DOES NOT REPRESENT BUILDING f O w s ill I.A1,s SCOPE OR VARIATIONS OF CONDITIONS 2. SHEET METAL FLASHING IS TO FULLY COVER SAM FROM ALL UV EXPOSURE SCOPE OR VARIATIONS OF CONDITIONS 1582nd Drive,Suite 10 3. SAM TO EXTEND OVER SIDES OF ELECTRICAL UTILITY BOXES. Gladstone,OR 97027 4. INSTALL LOW EXPANDING FOAM AROUND ALL PENETRATIONS TO LIMIT AIR LEAKAGE. TEL 503.772.1114 FAX 503.772.4039 5. IF PENETRATION DOES NOT FALL ALONG FRAMING, INSTALL STRAPPING OR BLOCKING AND www.forensicbuilding.com INTERMEDIATE FURRING STRIPS AS NEEDED FOR BLOCK AND SIDING TERMINATIONS. info@forensicbuilding.corn 6. PROVIDE EXTENSIONS WHERE NEEDED TO WIRING, PIPES, DUCTS, AND OTHER PENETRATIONS TO • '' I I' COPYRIGHT©2017 FORENSIC ' ;,� BUILDING CONSULTANTS I ACCOMMODATE INCREASED THICKNESS OF WALL ASSEMBLIES. ::, All Rights Reserved m OR CCB#155496 ���' '?.- WA FORENW C94308 \ ' u I \ , UT#8334529-5501 fS I \ EXISTING SHEATHING EXISTING SHEATHING _ SCHEDULED WRB, LAP OVER SAM A SCHEDULED WRB, LAP OVER QUICKFLASH FLASHING BELOW AND SEAL FLASHING BELOW AND SEAL ` SCHEDULED FIBER CEMENT PLANK LAP PRINT ALL DETAILS IN 24-GAUGE PRE-FINISHED METAL HEAD t illiiiii \ CLADDING COLOR AT 11x17 FLASHING SET ON BEAD OF SEALANT. QUICKFLASH PANEL CLIENT FILL VOIDS AT EDGES WITH SEALANT N 1 24-GAUGE PRE-FINISHED METAL HEAD Association of Unit I 1 FLASHING SET ON CONTINUOUS BEAD OF Owners of Touchstone 2° SEALANT ` 1� i W SEALANT. FILL VOIDS AT EDGES WITH Townhomes uIN ♦ SEALANT Iii �� ISSUE ' ^ FIBER CEMENT TRIM BLOCK, PRIME ""�_� PRIOR TO SEALANT INSTALLATION, 06.05.2018 iiiiiii...110 J�� 4 (TYP.) 1/ 'MIN. * v�• • Construction Issue Set _�� EXISTING HOSE BIBB REVISIONS • EXISTING PIPE II-- �TO REMAIN, REPLACE 1/2" X / 1/2" MIN. AS NECESSARY. gEv. DATE illk III �� PENETRATION. 4" 1/2" 1� . i► ` , REMOVE AND REINSTALL / v v. \ 1/2" .v EXISTING LIGHT FIXTURE ° �t1/2" SEALANT X1/2" \ MINIMALLY EXPANDING FOAM 5/4 FIBER CEMENT TRIM BLOCK, PRIME •' �` PROJECT NAME PRIOR TO SEALANT INSTALLATION, (TYP.) QUICKFLASH PANEL WRAP WALL qq FILLET BEAD OF SEALANT(TYP.) ` TRANSITION TO JUNCTION BOX 6 SEALANT(TYP.) FOR AIR SEAL Touchstone Townhomes gTargeted Building I SEALANT FILLET JOINT Enclosure Rehabilitation SEALANT FOR AIR SEAL 1 SCHEDULED PRESSURE TREATED PROJECT NUMBER w ` SCHEDULED PRESSURE TREATED FURRING STRIPS WITH INSECT FURRING STRIPS WITH INSECT \ SCREENS AT TERMINATIONS (R) 17-091 SCREENS AT TERMINATIONS ",� SHEET NAME 1-'''''''n ""° 1 SCHEDULED FIBER CEMENT PLANK LAP _ WALL '--- - / I ` CLADDING DETAILS 3.38 RECESSED FIXTURE / J-BOX 3.39 HOSE BIBB / PIPE PENETRATION SHEET NUMBER 3" = 1'-0" WITH MOUNTING BLOCK AT FIBER CEMENT CLADDING 3" = 1'-0" WITH MOUNTING BLOCK AT FIBER CEMENT CLADDING 3.38 mhg mhg 3.39 NOTES: FORENSIC 1. CONTRACTOR TO VERIFY AND MAINTAIN ALL RATED WALL ASSEMBLIES ,, ,I S f o Y B B t r d.I 2. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS 1582nd Drive,Suite 10 3. SHEET METAL FLASHING IS TO FULLY COVER SAM FROM ALL UV EXPOSURE Gladstone,OR 97027 4. INSTALL LOW EXPANDING FOAM AROUND ALL PENETRATIONS TO LIMIT AIR LEAKAGE. TEL 503.772 1114 FAX:503.772.4039 5. IF PENETRATION DOES NOT FALL ALONG FRAMING, INSTALL STRAPPING OR BLOCKING www.forensicbuilding.com AND INTERMEDIATE FURRING STRIPS AS NEEDED FOR BLOCK AND SIDING TERMINATIONS. info@forensicbuilding.corn 6. PASSIVE LOUVER VENT JAMBS ARE TO BE DETAILED SIM TO WINDOWS. COPYRIGHT©2017 FORENSIC BUILDING CONSULTANTS All Rights Reserved _ i OR CCB#155496 i t WA FORENW C94308 UT#8334529-5501 A . • PLYWOOD SHEATHING SCHEDULED SCHEDULED WRB 1 Io' Iempop... WRB, LAP OVER WRB AND SAM BELOW 0 SCHEDULED FIBER CEMENT PLANK LAP AND SEAL CLADDING I SCHEDULED PRESSURE TREATED ` 2� r I .- 1 FURRING STRIPS WITH INSECT 24-GAUGE PRE-FINISHED METAL HEAD MIN. ' SCREENS AT TERMINATIONS ' I I FLASHING WITH UP TURNED END DAMS :t COLOR AT 11 x17 ti„N• AND HEMMED DRIP EDGE-SET ONTO A PRINT ALL DETAILS IN 4w•• 2„ P i \ I I ,_4 BEAD OF SEALANT AND FILL VOIDS AT CLIENT MIN. 1110 EDGES FIBER CEMENT CLADDING ` U Association of Unit — Owners of Touchstone IM •., \ Townhomes 24 GA. PRE-PRIMED METAL HEAD SCHEDULED 5/4 FIBER CEMENT TRIM ISSUE FLASHING SET ON BEAD OF SEALANT. N C) � ♦ • FILL VOIDS AT EDGES WITH SEALANT 06.05.2018 • :• Alk, _.-------- ) \ '. "440 PRE-MANUFACTURED STATIC Ik%41 • V .• DATE REV LOUVER FIXTURE ASSEMBLY Construction Issue Set /A� ': i. REVISIONS nY i . ' 41101b .• CONTINUOUS SAM BEHIND BLOCKING ��„ �•` `. •�� 5/4" (1" NOM.)x 10"x 10"FIBER CEMENT TRIM IINT '—_ BLOCK, PRIME PRIOR TO SEALANT 1/2"• —_—__ Eillia. . ` • INSTALLATION, (TYP.) COORDINATE LOCATION 1., • AND HEIGHT PER OWNER'S REQUIREMENTS. ` 1/2" PROJECT NAME SOLID BLOCKING ° •t•' `N i — • I 1' 24 GAUGE PRE FINISHED METAL HEAD Touchstone Townhomes L ...soill. FLASHING WITH UP-TURNED END DAMS I AND HEMMED DRIP EDGE SET ONTO A Targeted Building N BEAD OF SEALANT FILL VOIDS AT EDGES Enclosure Rehabilitation 0 . ,I STATIC FILLET JOINT (TYP.) i tPROJECT NUMBER -T I '- + (R) 17 091 SCHEDULED FIBER CEMENT PLANK LAP CLADDING SHEET NAME WRB SCHEDULED PRESSURE TREATED FURRING STRIPS WITH INSECT WALL SCREENS AT TERMINATIONS DETAILS 3.40 NON-PENETRATING MOUNTING BLOCK 3.41 STATIC LOUVER FIXTURE FLASHING SHEET NUMBER 3" = 1'-0" AT FIBER CEMENT PLANK LAP CLADDING 3" = 1'-0" WITH MOUNTING BLOCK AT FIBER CEMENT PLANK LAP CLADDING 3.40 mhg 3.41 NOTE: FORENSIC 1. JAMBS OF HEAD FLASHING TO LAP OVER AND COVER CONDUIT FLASHING. Bal 1 BINC [Ma 5 0 LIANIS 2. IF APPLICABLE, WIDTH OF ELECTRICAL METER HOOD FLASHING TO ALLOW FOR JAMB FLASHINGS AND 1/2" 1582nd Drive,Suite 10 DYNAMIC SEALANT JOINTS. Gladstone,OR 97027 TEL:503.772.1114 3. ENSURE THAT NEWLY INSTALLED COMPONENTS DO NOT IMPEDE ACCESS INTO ELECTRICAL METER. FAX 503.772.4039 4. TUCK JAMB FLASHING UNDERNEATH HEAD FLASHING www.forensicbuilding.corn 5. PROVIDE EXTENSIONS WHERE NEEDED TO WIRING, PIPES, DUCTS, AND OTHER PENETRATIONS TO info@forensicbuilding.com ACCOMMODATE INCREASED THICKNESS OF WALL ASSEMBLIES. COPYRIGHT©2017 FORENSIC BUILDING CONSULTANTS 6. COORDINATE ELECTRICAL TRADE INSTALLATION WITH EXTERIOR CLADDING WORK All Rights Reserved OR CCB#155496 WA FORENW C94308 UT#8334529-5501 EXISTING SHEATHING ' SCHEDULED WRB, LAP OVER WRB AND SAM BELOW AND SEAL PRESSURE TREATED FURRING SCHEDULEDAND 4,; STRIPS WITH INSECT SCREENS AT TERMINATIONS — 1/2" PRINT ALL DETAILS IN SCHEDULED FIBER CEMENT PLANK LAPCOLOR AT 11x17 CLADDING \ 1/2 CLIENT 1/2" PIPE DIA. 1" 24-GAUGE PRE-FINISHED METAL HEAD FLASHING SET ON BEAD OF SEALANT. FILL VOIDS AT EDGES Association of Unit J.1 '4111111110 WITH SEALANT \ Owners of Touchstone CONTINUOUS SEALANT Townhomes y► 1/2 PIPE DIA. MIN. ISSUE FIBER CEMENT TRIM BLOCK, PRIME PRIOR TO SEALANT INSTALLATION, (TYP.) SET HEIGHT PER 06.05.2018 ' 111111110 I, . Construction Issue Set OWNER'S REQUIREMENTS. DYNAMIC SEALANT JOINT, CONTINUOUS AT SIDES = REVISIONS A/C CONDUIT UNIVERSAL CURVED ,, gEv. DATE QUICKFLASH PANEL SCHEDULED PRESSURE TREATED ��== - FURRING, TYP. 1? At \ A � ) SCHEDULED WRB • IINSTALLED AC CONDUIT PROVISIONS , / .1 / / / / '44111111.. J l' •• 7 `� / ' 1111 PROJECT NAME 47.614;7 ( f" Touchstone Townhomes SEALANT FOR AIR SEAL 1 / \ Targeted Building !� a STATIC FILLET JOINT(TYP.) STATIC FILLET JOINT(TYP.) Enclosure Rehabilitation SCHEDULED TRIM PROJECT NUMBER IN. FLUID APPLIED WRB STATIC FILLET JOINT(TYP.) (R) 17-091 /„�. , 24-GAUGE PRE-FINISHED METAL SHEET NAME _..- -/ �� CHANNEL FLASHING WALL SCHEDULED WRB EXISTING ELECTRICAL CONDUIT DETAILS 3.42 GANGED UTILITY PENETRATION FLASHING 3.43 METER BASE CONDUIT FLASHING SHEET NUMBER 3" = 11-0" WITH MOUNTING BLOCK AT FIBER CEMENT PLANK LAP CLADDING 3" = 1'-0" AT FIBER CEMENT PLANK LAP CLADDING 3.42 mhg mhg 3.00 Wall Details-Touchstone Townhomes.dwg 3.43 NOTE: FORENSIC 1. JAMBS OF HEAD FLASHING TO LAP OVER AND COVER CONDUIT FLASHING. a° r° r°°s°<<a. s 2. IF APPLICABLE,WIDTH OF ELECTRICAL METER HOOD FLASHING TO ALLOW FOR JAMB FLASHINGS AN[ " 1582nd Drive,Suite 10 4 „:, DYNAMIC SEALANT JOINTS. GTEL`50 772 1114 OR 9 027 3. ENSURE THAT NEWLY INSTALLED COMPONENTS DO NOT IMPEDE ACCESS INTO ELECTRICAL METER. FAX 503 772.4039 4. TUCK JAMB FLASHING UNDERNEATH HEAD FLASHING www.forensicbuilding.comm info@forensicbuilding.co 1 5. PROVIDE EXTENSIONS WHERE NEEDED TO WIRING, PIPES, DUCTS,AND OTHER PENETRATIONS TO COPYRIGHT©2017 FORENSIC ACCOMMODATE INCREASED THICKNESS OF WALL ASSEMBLIES. - BUILDING CONSULTANTS 6. COORDINATE ELECTRICAL TRADE INSTALLATION WITH EXTERIOR CLADDING WORK All Rights Reserved OR CCB#155496 WA FORENW 094308 SCHEDULED WRB, LAP OVER SAM ,;. UT#8334529-5501 FLASHING BELOW AND SEAL ' = 4 z ''''' / PRESSURE TREATED FURRING STRIPS WITH INSECT SCREENS AT TERMINATIONS SCHEDULED FIBER CEMENT PLANK LAP CLADDING .. -- SEALANT WRB LAP OVER VERTICAL LEG OF , : HEAD FLASHING AND SEAL 2” .)I $ SAM, LAP ONTO UTILITY BOX 1" MIN. PRINT ALL DETAILS IN 2" ' COLOR AT 11x17 4 ;F 4„ CLIENT \ ya1 Association of Unit U 4 SEALANT Owners of Touchstone / 24-GAUGE PRE-FINISHED • 1/2" Townhomes — — / METAL HEAD FLASHING I50/MI-�PE 1" ISSUE ,--- I r WITH ENDS FOLDED DOWN I L---- OVER JAMB FLASHING AND I----==�.u- UPTURNED END DAMS, 1/2., 06.052018 PUNCH-LOCKED AND i Construction Issue Set VARIES— / SEALED. HEMMED DRIP / EDGE SET ONTO A BEAD OF MINIMALLY EXPANDING REVISIONS A V 4_ SEALANT AND FILL VOIDS AT REV. DATE AAV EDGES '4" FOAM At IW C — EXTEND JAMB FLASHING 1" PERiffl I — 3.24A PAST BOTTOM OF METER PROJECT NAME ti#4 211%.!•.»r iI ...i 2" MIN ITouchstone Townhomes STATIC FILLET JOINT Targeted Building �' (TYP.)TYP.i Enclosure Rehabilitation ! WRB LAP WRB OVER 4" FLANGE `` , r /1/2" 1/2" DYNAMIC SEALANT PROJECT NUMBER FURRING STRIP JOINT(TYP.) (R) 17-091 STATIC SEALANT JOINT i , •• 24-GAUGE PRE-FINISHED METAL SHEET NAME • FLASHING WITH HEMMED EDGE / WALL DETAILS 3.44 RECESSED METER BASE HEAD 3.45 RECESSED METER BASE JAMB FLASHING SHEET NUMBER 3" = 1'-0" AT FIBER CEMENT PLANK LAP CLADDING 3" = 1'-0" PLAN VIEW-AT FIBER CEMENT PLANK LAP CLADDING 3.44 mhg 3.00 Wall Details-Touchstone Townhomes.dwg mhg 3.00 Wall Details-Touchstone Townhomes.dwg 3.45 NOTES: EXAMPLE OF EXISTING OBSERVED 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED WALL ASSEMBLIES FORENSIC 2. SHEET METAL FLASHING IS TO FULLY COVER SAM FROM ALL UV EXPOSURE CONDITION. PHOTO DOES NOT REPRESENT BU (e IIL i u v s u i i n a,s SCOPE OR VARIATIONS OF CONDITIONS 1582nd Drive,Suite 10 3. SAM TO EXTEND OVER SIDES OF ELECTRICAL UTILITY BOXES. Gladstone,OR 97027 4. INSTALL LOW EXPANDING FOAM AROUND ALL PENETRATIONS TO LIMIT AIR LEAKAGE. _ t. '` TEL 503 772.1114 - FAX:503 772.4039 5. PROVIDE EXTENSIONS WHERE NEEDED TO PIPES, DUCTS, AND OTHER PENETRATIONS TO '',:14,:.•••,-- -. www.forensicbuilding.com ACCOMMODATE INCREASED THICKNESS OF WALL ASSEMBLIES. info@forensicbuilding.com 6. AT DYNAMIC SEALANT JOINTS, MAINTAIN JOINT DEPTH AT ONE HALF JOINT WIDTH. '. ' COPYRIGHT©2017 FORENSIC 7. ENSURE NEWLY INSTALLED COMPONENTS DO NOT IMPEDE ACCESS TO ELECTRIC METER. ' i ` BUILDING CONSULTANTS All Rights Reserved WAOR CCB#155443096 FORENW C98 UT#8334529-5501 ...8 _ ii WRB, SHINGLE LAP OVER UP LEG OF METAL HEAD FLASHING HEAD FLASHING EXISTING SHEATHING WITH ENDS FOLDED DOWN OVER JAMB FLASHING. FABRICATE ALL SEAMS PRINT ALL DETAILS IN j WATER TIGHT. HEMMED COLOR AT 11x17 WRB - RUN PAST ROUGH OPENING SAM WRAP, INCLUDE DRIP EDGE "' CLIENT PATCHES AT ALL CORNER VOIDS, '- Association of Unit EXTEND 1" MIN. CONTINUOUS Owners of Touchstone OVER ONTO SIDES SEALANT Townhomes OF UTILITY BOX CONTINUOUS , ISSUE SEALANT FORZN ( 06.05.2018 X - AIR SEAL TYP. 6" 4' IF AT R.O.WRB MIN. Construction Issue Set } REVISIONS 1/2" DYNAMIC Ei_ < REV. DATE SEALANT JOINT cAT EACH JAM l kms- FIBER CEMENT • CLADDING NOT r SHOWN / PROJECT NAME AIR SEAL TYP. 1 AT R.O.WRB Touchstone Townhomes MIN. Targeted Building Enclosure Rehabilitation SHEET METAL JAMB r EXISTING UTILITY FLASHING EA. SIDE INSTALL P.T. PROJECT NUMBER BOX (NOT SHOWN WITH HEMMED EDGE. FURRING FOR CLARITY) TUCK UNDER HEAD STRIPS (NOT f (R) 17-091 FLASHING SHOWN) SHEET NAME WALL DETAILS 3.46 UTILITY PANEL INSTALLATION SHEET NUMBER 1" = 1'-0" ISOMETRIC SEQUENCE mhg 3.46 NOTES: EXAMPLE OF EXISTING OBSERVED FORENSIC 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED WALL ASSEMBLIES CONDITION. PHOTO DOES NOT REPRESENT a u e s a 5 <<,N IS 2. SHEET METAL FLASHING IS TO FULLY COVER SAM FROM ALL UV EXPOSURE SCOPE OR VARIATIONS OF CONDITIONS 3. SAM TO EXTEND OVER SIDES OF ELECTRICAL UTILITY BOXES. DO NOT INSTALL SAM AT BOTTOM OF BOX. 15 82nd Drive,Suite to ;. tt, . Gladstone,OR 97027 4. INSTALL MINIMALLY EXPANDING FOAM AROUND ALL PENETRATIONS TO LIMIT AIR LEAKAGE. TEL 503.7721114 5. IF PENETRATION DOES NOT FALL ALONG FRAMING, INSTALL STRAPPING OR BLOCKING AND INTERMEDIATE FAX:503.772.4039 " .��!..� _ "•••-... .. . www.forensicbuilding.com FURRING STRIPS AS NEEDED FOR BLOCK AND SIDING TERMINATIONS. 76... nfo@forensicbuilding.com 6. PRIME FLASHING PRIOR TO INSTALLATION, COORDINATE FLASHING FINISH COLOR WITH OWNER. 'R ; ,, COPYRIGHT 02017 FORENSIC 7. BUTYL-BASED, FOIL-FACED SAM FLASHING TO EXTEND AROUND PERIMETER OF FIREPLACE EXHAUST BOXES ' BUILDING CONSULTANTS N.1 Iv All Rights Reserved SCHEDULED WRB . �•� fit.-::' OR CCB#155496 v �""''`'` WA FORENW C94308 P - SCHEDULED PRESSURE TREATED FURRING UT#8334529-5501 1/ } WITH INSECT SCREEN f —CONTINUOUS SEALANT °` . r 2„ R BUTYL-BASED, FOIL-FACED SAM FLASHING- MIN. I SEAL TO PERIMETER OF VENT SCHEDULED WRB l 1 1 2III I FIBER CEMENT PLANK LAP CLADDING IN. ' ' 1• ►I 1/2" 24-GAUGE PRE-PRIMED METAL HEAD FLASHING Ill MIN. WITH HEMMED EDGE SET ONTO CONTINUOUS '��1 BEAD OF HIGH-TEMP SEALANT. EXTEND OVER PRINT ALL DETAILS IN .,..„,., , ,— SIDES AND FILL VOIDS AT EDGES WITH COLOR AT 11x17 ( '� SEALANT- FOLDED END DAMS CLIENT C 1 j. Q Association of Unit EXISTING FIREPLACE VENT HOOD Owners of Touchstone / 0 ASSEMBLY TO BE FLASHING IN Townhomes PLACE �_ Q ISSUE J = ( ) 06.05.2018 ( ) r"----1 Construction Issue Set ( REVISIONS C REV. DATE ----_. ��_ ... ( ) _�... 1 U C- . 1 O _ U -__ ,,,, -- 1/2" PROJECT NAME MIN. DYNAMIC SEALANT JOINT AT BASE OF VENT- Touchstone Townhomes I i4 SEAL TO SAM SURFACE. - DETAIL SIDES SIMILAR Targeted Building Enclosure Rehabilitation ) I 0 ti PREFINISHED METAL PERIMETER TRIM FLASHING PROJECT NUMBER BUTYL BASED, FOIL FACED SAM FLASHING SEAL TO PERIMETER OF VENT (R) 17-091 SCHEDULED PRESSURE TREATED FURRING SHEET NAME WITH INSECT SCREEN WALL SCHEDULED WRB DETAILS 3.47 FIREPLACE VENT FLASHING 3.48 NOT USED SHEET NUMBER 3" = 1-0" AT FIBER CEMENT PLANK LAP CLADDING 3.47 mhg 3.00 Wall Details-Touchstone Townhomes.dwg 3.48 NOTES: EXAMPLE OF EXISTING OBSERVED FORENSIC 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED WALL ASSEMBLIES. CONDITION. PHOTO DOES NOT REPRESENT SVIIDIIC G a N <I AN, 2. CAREFULLY REMOVE EXISTING TRIM AND ASSOCIATED FLASHINGS AT AREA TO BE REHABILITATED. EXISTING ROOF EAVE BLOCKING SCOPE OR VARIATIONS OF CONDITIONS 1582nd Drive,Suite 10 3. PREP AND PRIME TRIM AND CLADDING AS REQUIRED TO RECEIVE SEALANT AND PAINT. Gladstone,OR97027 4. FULLY COVER SAM FROM ALL UV EXPOSURE, TYPICAL. WITH VENT(AS OCCURS)TO TEL 503.772 1114 : REMAIN. CONTRACTOR TO FAX503.772.4039 www.forensicbuilding.com INSTALL ADDITIONAL ACHIEVE info@forensicbuilding corn CODE COMPLIANCE. COPYRIGHT©2017 FORENSIC BUILDING CONSULTANTS EXISTING 2x JOIST All Rights Reserved OR CCB#155496 I FRAMING BEYOND WA FORENW 094308 UT#8334529-5501 EXISTING ROOF EAVE BLOCKING WITH VENT(AS OCCURS)TO EXISTING 2x JOIST REMAIN. CONTRACTOR TO ADD FRAMING BEYOND WHERE NECESSARY TO ACHIEVE CODE COMPLIANCE. 7. . EXISTING COMPOSITION EXISTING COMPOSITION ASPHALT SHINGLE ASPHALT SHINGLE ROOFING TO REMAIN ROOFING TO REMAIN EXISTING ROOFING EXISTING ROOFING �'SEALANT UNDERLAYMENT TO UNDERLAYMENT TO REMAIN `` REMAIN PRINT ALL DETAILS IN EXISTING SHEATHING ?' EXISTING SHEATHING COLOR AT 11x17 TO REMAIN TO REMAIN CLIENT SEALANT �1 EXISTING METAL ROOF _.._h- EXISTING METAL ROOF EDGE FLASHING TO �_ Association of Unit EXISTING FASCIA ' i EXISTING FASCIA -- EDGE FLASHING TO Owners of Touchstone NT,, r TRIM TO REMAIN "� REMAIN TRIM TO REMAIN REMAIN Townhomes �� '11111111 ISSUE 4"SAMI 4"SAM 4 ! : : 06.05.2018 1 I I i .... 7) 1 / Construction Issue Set 11111.1 l �_ 1 '� REVISIONS EXISTING all11°P- 1 I .NN—EXISTING '41111111111) N GUTTER TO I `� __ J GUTTER TO REV. DATE 410111/000- • ii; REMAIN ( ; SCHEDULED 4/4 FIBER REMAIN .- 11111. • CEMENT TRIM PRIME • SCHEDULED 5/4 FIBER CEMENT4t PRIOR TO SEALANT TRIM - PRIME PRIOR TO SEALANT INSTALLATION ` 1 ii INSTALLATION, (TYP.) Oft. A I SEALANT FILLET BEAD 4 FILLET BEAD OF r• -041011110 IIIIII —411101, ..: • 41 SEALANT, TYPICAL ` SCHEDULED FIBER CEMENT �— 011 SHINGLE PANEL CLADDING PROJECT NAME SCHEDULED FIBER CEMENT PLANK / ` 'SCHEDULED FIBER ENT BATTENS LAP OR SHINGLE PANEL CLADDING (BEYOND),ALIGN WITH CEMPANEL JOINTS Touchstone Townhomes AND SPACE TO MATCH EXISTING Targeted Building SCHEDULED PRESSURE TREATED Enclosure Rehabilitation alilli i41001. FURRING STRIPS WITH INSECT SCHEDULED PRESSURE TREATED FURRING STRIP WITH INSECT SCREEN PROJECT NUMBER SCREENS AT TERMINATIONS AT HORIZONTAL TERMINATIONS SCHEDULED WRB (R) 17-091 SCHEDULED WRB lil i le 10 SHEET NAME M..../ pillk : EXISTING SHEATHING MOW1111 EXISTING SHEATHING i WALL DETAILS'i 3.49 TOP-OF-WALL AT EAVE OVERHANG 3.50 TOP-OF-WALL AT EAVE OVERHANG SHEET NUMBER 3" = 1'-0" AT FIBER CEMENT PLANK LAP OR SHINGLE PANEL CLADDING 3" = 1'-0" AT FIBER CEMENT PANEL CLADDING 3.49 mhg mhg 3.50 NOTES: FORENSIC 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED ROOF AND WALL ASSEMBLIES. ,, ,, ,,,,, 2. CAREFULLY REMOVE EXISTING TRIM AND ASSOCIATED FLASHINGS AT AREA TO BE REHABILITATED. 1582nd Drive,Suite 10 3. PREP AND PRIME TRIM AND CLADDING AS REQUIRED TO RECEIVE SEALANT AND PAINT. REFER TO DETAIL 3.51 FOR SIMILAR Gladstone,OR 97027 4. FULLY COVER SAM FROM ALL UV EXPOSURE, TYPICAL. TEL:503.772 1114 TOP OF WALL COMPONENT ASSEMBLY EXISTING RAKE wwFAX:503.772.4039 w.forens icbuilding.corn FRAMING BEYOND info@forensicbuilding.corn COPYRIGHT 02017 FORENSIC BUILDING CONSULTANTS EXISTING COMPOSITION ASPHALTAll Rights Reserved ,�a SHINGLE ROOFING TO REMAIN ORCCB#155496 / 1 / ���� EXISTING METAL WA FORENW C94308 . EXISTING ROOFING _ 4 � �� ROOF EDGE UT#8334529-5501 UNDERLAYMENT TO REMAIN \ '., FLASHING TO !' * REMAIN ' � , EXISTING SHEATHING TO EXISTING RAKE ` •'yw REMAIN FRAMING BEYOND I I . EXISTING GABLE/ 74 -- RAKE FASCIA TO Se 24-GAUGE PRE-FINISHED BE REMOVED AND 11.11.1111111= '.'. METAL CORBEL FLASHING REINSTALLED AS / 1 J 1 EXISTING METAL \ ; WITH HEMMED EDGE SET NECESSARY ROOF EDGE IN COMPATIBLE SEALANT 2" MIN. 1/4"CLEAR FLASHING TO v / , MIN ,` DO NOT SEAL REMAIN 1/2 PRINT ALL DETAILS IN \ ; \ COLOR AT 11x17 • MIN. II. . 2" i , ' 2" CLIENT �� ,, SCHEDULED TRIM PRIME ALLli il'' \ �' L �' • Association of Unit CUTS PRIOR TO INSTALLATION, —) Owners of Touchstone 1 v 1 (TYP.) v C i / Townhomes COMPATIBLE SEALANT F j 1 — �' ISSUE ` 4"SAM \ 06.05.2018 EXISTING GABLE/RAKE \ FASCIA TO BE REMOVED 111 ,40 Construction Issue Set AND REINSTALLED AS REVISIONS •N NECESSARY N REV. DATE 4 SCHEDULED FIBER CEMENT PLANK v ..• LAP OR SHINGLE PANEL CLADDING —f— „ EXISTING WOOD CORBEL TO BE _.- N i REMOVED AND REINSTALLED N . SCHEDULED PRESSURE TREATED PROJECT NAME I V.I.F. i FURRING STRIPS WITH INSECT �� ��� , Z / / { SCREENS AT TERMINATIONS ! ' Touchstone Townhomes Targeted Building SCHEDULED WRB /'---,,— Enclosure Rehabilitation } 1 1 ti 1i 1. .r / 4" PROJECT NUMBER i i (R) 17-091 )1 I0 , EXISTING SHEATHING 1 11 I 1,7"----------- •N I 1 SHEET NAME L-- ' f LINE OF TRIM BEYOND 2 WALL V L DETAILS 3.51 TOP-OF-WALL TO GABLE/RAKE FASCIA 3.52 CORBEL FLASHING INTEGRATION DETAIL SHEET NUMBER 3" = 1-0" AT FIBER CEMENT PLANK LAP OR SHINGLE PANEL CLADDING 3" = 1'-0" AT GABLE/RAKE FASCIA 3.51 mhg 3.00 Wall Details-Touchstone Townhomes.dwg mhg 3.00 Wall Details-Touchstone Townhomes.dwg 3.52 FORENSIC BUIIUIUG CUUSULtANI; 0 '49. 15 Gladstonne,OR 97027 TEL:503.772.1114 \O 6 FAX 503.772.4039 I www.forensicbuilding.com A›,.\›'(. 110 www.forensicbuilding.com Oj -n ���' II COPYRIGHT©2017 FORENSIC _ \v�>/ At . BUILDING CONSULTANTS �G All Rights Reserved 4401011 1 �Q OR CCB#155496 1004 WA FORENW C94308 UT#8334529-5501 0 SLOPE MIN.2%TOWARD OUTSIDE OF R.O. EMETAL BACK ANGL INSTALL SAM PATCHES AT INSTALL 9"WIDE SAM CORNERS MIN.2"LAP IN FLASHING ALONG BOTH lQ'> ALL DIRECTIONS JAMBS OF THE ROUGH 9 OPENING STEP 1. STEP 2. STEP 3. PRINT ALL DETAILS IN B. SILL PAN COLORAT11x17 CLIENT 1. FIELD VERIFY WIDTH FOR EACH PAN TO AVOID"DRAPING"OF SAM INTO PANS. 2. SOLDER SEAMS. Association of Unit 3. FASTEN AT JAMBS. DO NOT PENETRATE HORIZONTAL SURFACE OF PAN. Owners of Touchstone Townhomes PROFILE SECTION ISSUE 06.05.2018 / Construction Issue Set 2" FASTENER \ REVISIONS ZONE REV. DATE 4" UP • / (N1 ,41b. LEG 41141111111411%1/11411) 1/2" ENDN 1/2"HIGH FOLDED END DAM �— DAMS, TYPICAL AT ALL °1)°-00,? PROJECT NAME 1/2" MIN. ��OT,y / THRU-WALL FLASHING 5%SLOPE @ 21 1/1/ 'WIDE DOWN LEG Z' PROVISIONS Touchstone Townhomes 1/2" 10%SLOPE @<1-1/2"WIDE HEMMED Targeted Building HEMMED DRIP EDGE KICK - Enclosure Rehabilitation (REMOVE SHARP PROJECT NUMBER EDGES) (R) 17-091 A. HEAD FLASHING SHEET NAME 1. DEPTH OF FLASHING TO BE 1/4"GREATER THAN THE DOOR OR WINDOW IT IS FLASHING. 2. CONTRACTOR TO VERIFY FLASHING DOES NOT INTERFERE WITH OPERATION OF WINDOWS OR DOORS. WALL OPENING DETAILS 4.00 TYPICAL WINDOW FLASHING SHEET NUMBER N.T.S. INSTALL LOCATIONS 4.o0 MA 4.00 Wall Opening Details-Touchstone Townhomes.dwg NOTES: EXAMPLE OF EXISTING OBSERVED CONDITION. EXAMPLE OF EXISTING OBSERVED CONDITION. FORENSIC 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED WALL ASSEMBLIES PHOTO DOES NOT REPRESENT COMPLETE PHOTO DOES NOT REPRESENT COMPLETE a I I.U I II G C G NS U 1.1 P N IS 2. METAL THRU WALL FLASHING IS TO BE COMPLETE WITH UPTURNED ENDS AT TERMINATIONS AND SCOPE OR VARIATIONS OF CONDITIONS. SCOPE OR VARIATIONS OF CONDITIONS. 1582nd Drive,Suite 10 CONTINUOUS AROUND CORNERS Gladstone,OR 97027 3. THREE-DIMENSIONAL DRAWINGS ARE INTENDED TO ILLUSTRATE SPECIFIC CONCEPTS OF TEL 503.772.1114 FAX:503.772.4039 COMPONENTS INSTALLATION. NOT ALL ASSEMBLY COMPONENTS ARE SHOWN. w _ -- l� - www.forensicbuilding.com �. info@forensicbuddmg com _ ,��, COPYRIGHT©2017 FORENSIC — kr:1, : '' — _ BUILDING CONSULTANTS ice` „;,Ya = All Rights Reserved „ OR CCB#155496 - __; '" `�' ;,;- i WA FORENW C94308 ' - " $$, UT#8334529-5501 b .. ..ate. . ..- I PRINT ALL DETAILS IN it COLOR AT 11x17 CLIENT /''7 / Association of Unit Owners of Touchstone Townhomes ISSUE 06.05.2018 -C.9* Construction Issue Set n0i . REVISIONS 1 I REV. DATE 611 TYP. // SEAL CORNERS i CONTRACTOR TOPROJECT NAME INSTALL 9"WIDE BUTYL BASED ENSURE SILL IS NOT SAM OVER PRE-FINISHED REVERSE SLOPED METAL ANGLE Touchstone Townhomes �yQ INSTALL SAM PATCHES AT Targeted Building INSTALL WRB RUN 6 11 Enclosure Rehabilitation CORNERS-MIN. 2"LAP IN PAST ROUGH OPENING ALL DIRECTIONS PROJECT NUMBER INSTALL 26-GAUGE PRE-FINISHED (R) 17-091 STEP 1 STEP 2 METAL BACK ANGLE- FOLD AND STEP 3 EXTEND TO EXTERIOR FACE OF SHEET NAME SHEATHING WALL OPENING DETAILS 4.01A TYPICAL VINYL WINDOW INSTALL SHEET NUMBER 1/2" = 110" ISOMETRIC DETAIL SEQUENCE 1 OF 4 4.01 A MA 4.00 Wall Opening Details-Touchstone Townhomes.dwg FORENSIC N U1 I UING CO USO ITANTS 15 82nd Drive,Suite 10 Gladstone,OR 97027 TEL 503.772.1114 FAX 503.772.4039 www.forensicbuilding.com info@forensicbuilding.com COPYRIGHT©2017 FORENSIC BUILDING CONSULTANTS All Rights Reserved OR CCB#155496 WA FORENW C94308 UT#8334529-5501 6" TYP. 5�Q PRINT ALL DETAILS IN COLOR AT 11x17 CLIENT Association of Unit Owners of Touchstone Townhomes ISSUE 06.05.2018 i Construction Issue Set REVISIONS REV. DATE ''lir=.. . '` PROJECT NAME Touchstone Townhomes INSTALL 9"WIDE BUTYL INSTALL PLASTIC MESH TO Targeted Bailding Enclosure Rehabilitation BASED SAM FLASHING PROMOTE DRAINAGE AT SILL. ALONG BOTH JAMBS OF STOP 2" FROM CORNER OF R.O. PROJECT NUMBER THE ROUGH OPENING ......,...!".„.„.•;!:.„......:„.„5,),..5§ INSTALL FLAT PLASTIC OR (R) 17-091 STEP 4 STEP 5 DECAY-RESISTANT PLASTIC SHIMS PER PRODUCT INFO SHEET NAME TO PROVIDE LEVEL AND FULL WALL OPENING SUPPORT FOR WINDOWS- DETAILS WHERE FRAMING ALLOWS 4.01 B TYPICAL VINYL WINDOW INSTALL SHEET NUMBER 1/2" = 1'0" ISOMETRIC DETAIL SEQUENCE 2 OF 4 4.01 B MA 4.00 Wall Opening Details-Touchstone Townhomes.dwg FORENSIC 841101/6 CON601IAN1S INSTALL A 3/8" DIAMETER CONTINUOUS BEAD OF 1582nd Drive,Suite 10 Gladstone,OR 97027 SAM COMPATIBLE POLYURETHANE SEALANT TO TEL:503.772.1114 FAX:503.772.4039 BACK SIDE OF WINDOW FLANGE ALONG THE HEAD FAX: 03.77 i l 403 Com AND JAMB OF WINDOW.ALIGN SEALANT WITH info@forensicbuilding.com PRE-PUNCHED FASTENER SLOTS IF PROVIDED. DO COPYRIGHT©2017 FORENSIC NOT APPLY SEALANT ALONG WINDOW SILL AREAr� I \ BUILDING CONSULTANTS All Rights Reserved / \ OR CCB#155496 \ WA FORENW C94308 / /Q UT#8334529-5501 A I 40,0°"' I // \ // 0 // l _ rr \ / 1.11 li r \� PRINT CO OR AT 11x17 ILS IN NO FASTENERS WITHIN 3"OF 3 FRAME CORNER. TYP. 10" MAX CLIENT ENSURE A CONTINUOUS 4$ Association of Unit UNBROKEN SEAL BETWEEN ' Owners of Touchstone FLASHING AND WINDOW NAILING Townhomes FLANGE ALONG THE HEAD AND \� JAMBS OF THE WINDOW. `3 1 ISSUE SEALANT SHOULD FLOW OUT AND FILL PRE-PUNCHED 06.05.2018 FASTENER SLOTS. ADD SEALANTConstruction Issue Set WHERE DEFICIENT.ALLOW SEALANT TO CURE BEFORE REVISIONS *N\\\ COVERING FLANGE REV. DATE ,d,lp / \ SECURE WINDOW USING PROPER ER ''' , .,,....r: .... ':° ,H___,/ \ FASTENERS AT SPACING 1 \ REQUIRED BY MANUFACTURER \ \ 1 PROJECT NAME Il i Touchstone Townhomes PROVIDE CONTINUOUS BEAD OF SEALANT 1 / / 11,—__7!_ \\ Targeted Building ALONG JAMB, JUST ABOVE SILL JUNCTURE,AND -► 0 , I Enclosure Rehabilitation AT BACKSIDE OF WINDOW FRAME TO INTERSECT - I WITH INTERIOR FINISH FOR AIR SEAL / PROJECT NUMBER O SECTION / (R) 17-091 STEP 6 DO NOT APPLY SEALANT ALONG BACK SIDE OF \ it STEP 7 FLANGE AT WINDOW SILL-SEE SILL SECTION DETAIL / SHEET NAME WALL OPENING DETAILS 4.01C TYPICAL VINYL WINDOW INSTALL SHEET NUMBER 1/2" = 1'0" ISOMETRIC DETAIL SEQUENCE 3 OF 4 410 C MA 4.00 Wall Opening Details-Touchstone Townhomes.dwg FORENSIC BUI L0I16 Cl USUII ANIS 15 82nd Drive,Suite 10 Gladstone,OR 97027 TEL:503.772.1114 FAX:503.772.4039 www.forens icbui ld ing.corn info@forensicbuilding.com COPYRIGHT©2017 FORENSIC BUILDING CONSULTANTS All Rights Reserved OR CCB#155496 WA FORENW C94308 UT#8334529-5501 9"STRIP OF SAM FLASHING ALONG BOTH JAMBS OF THE ROUGH INSTALL A 9"SAM FLASHING OPENINGS ALONG THE WINDOW HEAD 9.. 1-9;P. 7 �'\'Q. PRINT ALL DETAILS IN 1" dr COLOR AT 11x17 TYP. CLIENT Association of Unit Owners of Touchstone Townhomes Q' ISSUE 06.05.2018 Construction Issue Set REVISIONS REV. DATE Mg�Q. PROJECT NAME Touchstone Townhomes Targeted Building Enclosure Rehabilitation PROJECT NUMBER (R) 17-091 STEP 8 STEP 9 SHEET NAME WALL OPENING *METAL HEAD FLASHING AND WRB INTEGRATION NOT SHOWN FOR DETAILS CLARITY. 4.01 D TYPICAL VINYL WINDOW INSTALL * REINSTALL INTERIOR TRIM COMPONENTS, REPLACE DAMAGED SHEET NUMBER TRIM WITH LIKE KIND AND FINISH TO MATCH EXISTING. 1/2" = 1l0° ISOMETRIC DETAIL SEQUENCE 4 OF 4 /) MA 4.00 Wall Opening Details-Touchstone Townhomes.dwg *CLADDING NOT SHOWN FOR CLARITY. 4.01 D NOTE: FORENSIC 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED WALL ASSEMBLIES. B°I`B I"° `°°B B"A"' 2. METAL THRU WALL FLASHING IS TO BE COMPLETE WITH UPTURNED ENDS AT TERMINATIONS AND CONTINUOUS AROUND CORNERS. 15 82nd Drive,Suite 10 3. AT DYNAMIC SEALANT JOINTS, MAINTAIN JOINT DEPTH AT ONE HALF JOINT WIDTH. Gladstone,OR 97027 TEL:503.772.1114 4. ENSURE INSTALLED COMPONENTS ARE NOT VISIBLE BELOW SIDING AND/OR TRIM. FAX:503.772.4039 5. INSTALL MINIMALLY EXPANDING FOAM INSULATION AT HEAD ASSEMBLY AS NECESSARY. w. www.forensicbuilding.corn inforensicbuilding.corn 6. DETAIL4.02 SHOWS CONCEALED WINDOW HEAD INSTALLATION ASSEMBLY, REFER TO DETAI14.03 AND 4.04 FOR SEALANT, TRIM AND COPYRIGHT 02017 FORENSIC CLADDING COMPONENTS. BUILDING CONSULTANTS All Rights Reserved OR CCB#155496 EXISTING SHEATHING / WA FORENW C94308 UT#8334529-5501 ' :„.„....,.„.______„. ' • 1 ,.. .—Hilp. PRESSURE TREATED FURRING STRIP WITH SCHEDULED WRB, LAP OVER FLASHING AND INSECT SCREEN AT HORIZ. TERMINATIONS, SAM COMPONENTS BELOW 4110/00- TYP. _..ioill.':, ... SCHEDULED FURRING, REFER TO TRIM AND : ,:s ..iiiiiie CLADDING DETAIL FIBER CEMENT PLANK LAP CLADDING (FIBER CEMENT SHINGLE PANEL AND FIBER CEMENT PANEL CLADDING SIMILAR) 41000„._ _.00400 CLADDING AS DETAILED • 011ow.. ,' . • 4111 , PRINT ALL DETAILS IN 9" BUTYL BASED SAM, EXTEND DOWN AND 4" COLOR AT 11x17 OVER WINDOW FLANGE BELOWIIIIIIIIIIIIIIO 5% MIN SLOPE CLIENT 1/2" Association of Unit � • CONTINUOUS BEAD OF SEALANT FOR AIR SEAL ` • 1/2" Owners of Touchstone 1/2" Townhomes ' ISSUE % METAL HEAD FLASHING AS DETAILED 06.05.2018 9" ( I M1 1/2" 24-GAUGE PRE-FINISHED METAL HEAD Construction Issue Set SCHEDULED TRIM, REFER TO TRIM AND o.-- FLASHING (TYP)WITH UP-TURNED END 2" CLADDING DETAIL • • i DAMS AND HEMMED DRIP EDGE SET ON REVISIONS MIN. , i CONTINUOUS 3/8"BEAD OF SEALANT REV. DATE • CONTINUOUS BEAD OF SEALANT BEHIND I a SCHEDULED TRIM SIZE PER l = WINDOW FLANGE , ' �_ SPECIFICATIONS- PRIME PRIOR TO ISEALANT INSTALLATION (TYP.) 1/2" E4! ,r10111-On - i. L-71_1- VII 24-GAUGE PRE-FINISHED METAL INTERIOR BEAD �� PROJECT NAME 111 7 0 THRU-WALL FLASHING WITH END DAMS OF SEALANT ' AND HEMMED DRIP EDGE SET ON Touchstone Townhomes CONTINUOUS 3/8"BEAD OF SEALANT Targeted Building Enclosure Rehabilitation INSTALLED VINYL WINDOW ASSEMBLY PROJECT NUMBER (R) 17-091 �� _____\1\___ SHEET NAME WALL OPENING DETAILS 4.02 TYPICAL WINDOW HEAD - CONCEALED 4.03 TYPICAL WINDOW HEAD - TRIM AND SHEET NUMBER 3" = 1'0" COMPONENTS - INSTALL CONDITION 3" = 1'0" CLADDING COMPONENTS - INSTALL CONDITION 4.02 MA 4.00 Wall Opening Details-Touchstone Townhomes.dwg MA 4.00 Wall Opening Details-Touchstone Townhomes.dwg 4.03 NOTE: EXAMPLE OF EXISTING OBSERVED CONDITION. FORENSIC 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED WALL ASSEMBLIES. PHOTO DOES NOT REPRESENT COMPLETE 9 VI l11111CONSLIANIS 2. METAL THRU WALL FLASHING IS TO BE COMPLETE WITH UPTURNED ENDS AT TERMINATIONS AND SCOPE OR VARIATIONS OF CONDITIONS 15 82nd Drive,Suite 10 CONTINUOUS AROUND CORNERS. Gladstone,OR 97027 TEL.503.772 1114 3. AT DYNAMIC SEALANT JOINTS, MAINTAIN JOINT DEPTH AT ONE HALF JOINT WIDTH. FAX 503.7724039 4. ENSURE INSTALLED COMPONENTS ARE NOT VISIBLE BELOW SIDING AND/OR TRIM. ¥ info forensicbuilding.com r info@forensicbuilding.corn 5. INSTALL MINIMALLY EXPANDING FOAM INSULATION AT JAMB ASSEMBLY AS NECESSARY. co 6. FORENsIc 6. DETAIL4.02 SHOWS CONCEALED WINDOW HEAD INSTALLATION ASSEMBLY, REFER TO DETAI14.03 AND ` `:`" BUILDING CONSULTANNS 4.04 FOR SEALANT, TRIM AND CLADDING COMPONENTS. N r All Rights Reserved SCHEDULED WRB, LAP OVER FLASHING ANDtali OR CCB#155496 ? WAFORENWC94308 WRB COMPONENTS BELOW I : i UT#8334529-5501 OmoNJ JL CONTINUOUS BEAD OF SEALANT FOR AIR-SEAL z / .7- , 2" FIBER CEMENT SHINGLE PANEL CLADDING i MIN. 24-GAUGE PRE-FINISHED METAL FLASHING (TYP)WITH END DAMS AND HEMMED DRIP 411.111100,... EDGE SET ON CONTINUOUS BEAD OF SEALANT -!,....0000 PRINT ALL DETAILS IN - SCHEDULED BELLY BAND TRIM SIZE PER COLOR AT 11x17 �_ SPECIFICATIONS- PRIME PRIOR TO SEALANT CLIENT INSTALLATION (TYP.) Association of Unit • \ Owners of Touchstone Townhomes - .0111111110,- , < 4.. ISSUE a 5% MIN SLOPE 06.05.2018 ° • /2 a♦ 1/2" Construction Issue Set a ` 1/2" REVISIONS .' I REV. DATE FIBER CEMENT PANEL AND BATTEN CLADDING I ` 1/2" 24-GAUGE PRE-FINISHED METAL HEAD „---- FLASHING WITH UP-TURNED END DAMS AND I i HEMMED DRIP EDGE SET ON CONTINUOUS 3/8"BEAD OF SEALANT i I I i a SCHEDULED TRIM - SIZE PER PROJECT NAME SPECIFICATIONS- PRIME PRIOR TO l 1/2" SEALANT INSTALLATION (TYP.) Touchstone Townhomes [ 1-11-TE1/1- Targeted Building v WE Enclosure Rehabilitation PROJECT NUMBER INTERIOR BEAD OF SEALANT �' I (R) 17-091 SHEET NAME WALL OPENING DETAILS 4.04 WINDOW HEAD - FIBER CEMENT TRIM, 4.05 NOT USED SHEET NUMBER 3" = 1'0" TRIM BAND, AND CLADDING COMPONENTS - INSTALL CONDITION 3" = 1'0" 4.04 MA 4.00 Wall Opening Details-Touchstone Townhomes.dwg XX 4.00 Wall Opening Details-Touchstone Townhomes.dwg 4.05 NOTE: FORENSIC 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED WALL ASSEMBLIES. BVIIIIYG IS 2. METAL THRU WALL FLASHING IS TO BE COMPLETE WITH UPTURNED ENDS AT TERMINATIONS AND 15 82nd Drive,Suite 10 CONTINUOUS AROUND CORNERS. Gladstone,OR 97027 3. AT DYNAMIC SEALANT JOINTS, MAINTAIN JOINT DEPTH AT ONE HALF JOINT WIDTH. TEL:503.772.1114 FAX:503.772.4039 4. ENSURE INSTALLED COMPONENTS ARE NOT VISIBLE BELOW SIDING AND/OR TRIM. www.forensicbuilding.com 5. INSTALL MINIMALLY EXPANDING FOAM INSULATION AT JAMB ASSEMBLY AS NECESSARY. nfo@forensicbuilding.com 6. DETAIL4.06 SHOWS CONCEALED WINDOW JAMB INSTALLATION ASSEMBLY, REFER TO DETAI14.07 FOR COPYRIGHT©2017 FORENSIC BUILDING CONSULTANTS TRIM AND CLADDING COMPONENTS. All Rights Reserved OR CCB#155496 WA FORENW C94308 UT#8334529-5501 SEALANT FILLET BEAD PRINT ALL DETAILS IN EXISTING COLOR AT 11x17 SHEATHINGPRESSURE TREATED SCHEDULED TRIM -SIZE PER CLIENT 9"BUTYL BASED SAM FURRING STRIPS SPECIFICATIONS- PRIME PRIOR SCHEDULED WRB TO SEALANT INSTALLATION (TYP.) Association of Unit CLADDING AS FIBER CEMENT Owners of Touchstone DETAILED CONTINUOUS BEAD OF SEALANT CLADDING DYNAMIC SEALANT JOINT Townhomes BEHIND WINDOW FLANGE 1/211ISSUE INSTALLED VINYL WINDOW 06.05.2018 i —\ ASSEMBLY _� ___ Construction Issue Set -" fd I" I 6 REVISIONS �� ��\ �\ ' 171�� ` \ Olt ' \ ❑�'>]tl��n REV. DATE 211 MIN.( �T Qr1 �; 1 / . 1..,-. ! y \ \\ / INTERIOR BEAD OF SEALANT /titill1 PROJECT NAME Touchstone Townhomes 9" BUTYL-BASED SAM, EXTEND Targeted Building INTO ROUGH OPENING Enclosure Rehabilitation PROJECT NUMBER (R) 17-091 SHEET NAME WALL OPENING DETAILS 4.06 TYPICAL WINDOW JAMB - CONCEALED 4.07 TYPICAL WINDOW JAMB - TRIM AND SHEET NUMBER 3" = 1'0" COMPONENTS - INSTALL CONDITION 3" = 1'0" CLADDING COMPONENTS - INSTALL CONDITION 4.06 MA 4.00 Wall Opening Details-Touchstone Townhomes.dwg MA 4.00 Wall Opening Details-Touchstone Townhomes.dwg 4.07 EXAMPLE OF EXISTING OBSERVED CONDITION. NOTE EXAMPLE OF EXISTING OBSERVED CONDITION. FORENSIC PHOTO DOES NOT REPRESENT COMPLETE 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED WALL ASSEMBLIES. PHOTO DOES NOT REPRESENT COMPLETE a°'`°'"° `°°'°"""' SCOPE OR VARIATIONS OF CONDITIONS 2. METAL THRU WALL FLASHING IS TO BE COMPLETE WITH UPTURNED ENDS AT TERMINATIONS AND SCOPE OR VARIATIONS OF CONDITIONS 1582nd Drive,Suite 10 CONTINUOUS AROUND CORNERS. Gladstone,OR 97027 TEL 503 772.1114 3. AT DYNAMIC SEALANT JOINTS, MAINTAIN JOINT DEPTH AT ONE HALF JOINT WIDTH. FAX-503.772.4039 ' : i 4. ENSURE INSTALLED COMPONENTS ARE NOT VISIBLE BELOW SIDING AND/OR TRIM. nfo forensicbuilding.corn ` info@forensicbuilding.com a 5. INSTALL MINIMALLY EXPANDING FOAM INSULATION AT JAMB ASSEMBLY AS NECESSARY. i COPYRIGHT 02017 FORENSIC - I - , BUILDING CONSULTANTS All Rights Reserved �, OR CCB#155496 WA FORENW C94308 J7. Ng ' ' UT#8334529-5501 RABBET JOINT 1-SIDE OF ACORNER TRIM - PRIME 1/2" BEFORE INSTALLING SEALANT(TYP.) CONTINUOUS BEAD OF SEALANT 1/2"� BEHIND WINDOW FLANGE BUTYL-BASED SAM FLASHING PRE-WRAP SCHEDULED TRIM INTERIOR BEAD OF SEALANT PRINT ALL DETAILS IN PRESSURE TREATED \ .' BUTYL BASED SAM COLOR AT 11x17 FURRING STRIPS CLIENT , il BUTYL-BASED SAM Association of Unit FLASHING » IIo Owners of Touchstone SEALANT AT TRIM BUTT 1/2 DYNAMIC SEALANT ❑ p Townhomes JOINT JOINT(TYP.) \ o1 a F7 ISSUE e I- 06.05.2018 `� v ------------1 • 4 1/2" • N n /�t DYNAMIC SEALANT ,‘ N\ G-� a r MIN. \ •• L3 1/2" JOINT(TYP.) Construction Issue Set ❑, �- o ' _ ' 0-. 1A- 5]II�, l �,_._________ ,, �� REVISIONS ') \ rJ SCHEDULED TRIM- SIZE PER SPECIFICATIONS- REv. DATE PRIME PRIOR TO SEALANT INSTALLATION (TYP.) 2" r MIN. SEALANT FILLET BEAD INTERIOR BEAD OF SEALANT9"STRIP OF BUTYL-BASED SAM CENTERED AT CORNER ( III i/ FIBER CEMENT CLADDING 1�_1, y . r-- e� PROJECT NAME -- ‘‘:::\::\ vi SCHEDULED WRB ��f._ Touchstone Townhomes OA , 7'- EXISTING SHEATHING TareteEnclosure dRBuil citation ng ,JIB NOTE: COMPONENTS SIMILAR AT R ,\'\ 45 DEGREE CORNER WALL JOINT , L_ \ PROJECT NUMBER CONDITION. TRIM CONFIGURATION PRESSURE TREATED FURRING STRIP WITH MAY VARY SLIGHTLY, REF. DETAIL \ INSECT SCREEN AT HORIZONTAL (R) 17-091 3.11 AND 3.13. / TERMINATIONS, TYP. / SHEET NAME WALL OPENING DETAILS A 4.08 WINDOW JAMB - OUTSIDE CORNER 4.09 WINDOW JAMB - INSIDE CORNER SHEET NUMBER 3" = 1'0" BAY POP-OUT P-OUT- INSTALL CONDITION 3" = 1'0" BAY POP-OUT- INSTALL CONDITION 4.08 MA 4.00 Wall Opening Details-Touchstone Townhomes.dwg MA 4.00 Wall Opening Details-Touchstone Townhomes.dwg 4.09 NOTE: FORENSIC 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED WALL ASSEMBLIES. I {O K S D I I A N I S 2. METAL THRU WALL FLASHING IS TO BE COMPLETE WITH UPTURNED ENDS AT TERMINATIONS AND 15 82nd Drive,Suite 10 CONTINUOUS AROUND CORNERS. Gladstone,OR 97027 3. AT DYNAMIC SEALANT JOINTS, MAINTAIN JOINT DEPTH AT ONE HALF JOINT WIDTH. TEL:503.772.1114 FAX:503.772.4039 4. ENSURE INSTALLED COMPONENTS ARE NOT VISIBLE BELOW SIDING AND/OR TRIM. www.forensicbuilding.corn 5. DETAIL 4.04 SHOWS CONCEALED WINDOW JAMB INSTALLATION ASSEMBLY, REFER TO DETAIL 4.06 FOR info@forensicbuilding.com TRIM AND CLADDING COMPONENTS. COPYRIGHT©2017 FORENSIC 6. DETAIL4.10 SHOWS CONCEALED WINDOW SILL INSTALLATION ASSEMBLY, REFER TO DETAIII.11 AND BUILDING CONSULTANTS All Rights Reserved 4.12 FOR TRIM AND CLADDING COMPONENTS. OR CCB#155496 WA FORENW C94308 UT#8334529-5501 V.I.F. FOR 1/2" LAP ONTO FRAME • 1/4 INSTALLED VINYL WINDOW ASSEMBLY V.I.F. —1/— CONTINUOUS SEALANT BETWEEN FRAME AND BACK ANGLE, ENSURE SEALANT IS COMPATIBLE WITH SAM AT METAL ANGLE. • 24-GAUGE PRE-FINISHED SEALANT FOR AIR SEAL METAL FASTENING ANGLE INTERIOR FILLET BEAD PRINT ALL DETAILS IN WITH 1/2"OVERLAP ONTO CONTINUOUS SHIM AS REQUIRED TO OF SEALANT TYP I COLOR AT 11x17 FRAME NEGATE ANY REVERSE SLOPING OR 6" PONDING AT THE WINDOW SILLI CLIENT -- -� INTERIOR SILL TRIMIlk;..,..' TRIM AND SILL FINISHe ro INTERMITTENT DECAY-RESISTANT SHIMS TO 1 Association of Unit [ripli,tPROVIDE LEVEL SUPPORT TO MATCH EXISTIN AS DETAILED 1 ;ri I q_. _� DYNAMIC SEALANT JOINT(TYP.) OwnersTownhomesstone [7 f ' 7 ❑� I ► - 1/2" ISSUE L..1000,,-I ► 06.05.2018 , Io"PLASTIC MESH SPACER OR HORSE-SHOE ik , SCHEDULED TRIM, RABBET BOTTOM SHIM AS COMPOSITE SHIM BEHIND FLANGE t OF TRIM FOR INTEGRATION OF FIBER Construction Issue Set ' INTERIOR TRIM- � ° CEMENT CLADDING (NOTE: CONTINUE REVISIONS REQUIRED 12" BUTYL-BASED SAM ' RABBET ALONG BOTTOM OF JAMB TRIM TYPICAL EACH SIDE)-SIZE PER REV. DATE CONTINUOUS • ,,° SPECIFICATIONS PRIME PRIOR TO 9" • PLYWOOD SHI ( SEALANT INSTALLATION (TYP) \ . Ommow._ ,, . C CLADDING, REFER TO TRIM AND (. • CLADDING DETAIL CONTINUOUS FILLET BEAD OF SEALANT PROJECT NAME PRESSURE TREATED FURRING STRIP WITH INSECT SCREEN AT HORIZ. FIBER CEMENT PLANK LAP CLADDING TERMINATIONS, TYP. Touchstone Townhomes 1081 (FIBER CEMENT SHINGLE PANEL AND Targeted Building -0/111410 FIBER CEMENT PANEL CLADDING Enclosure Rehabilitation WRB SIMILAR) PROJECT NUMBER PLYWOOD SHEATHING (R) 17-091 _..71.070 ,,aii_11.____*____________--- SHEET NAME WALL OPENING DETAILS 4. 10 TYPICAL WINDOW SILL - CONCEALED 4. 11 TYPICAL WINDOW SILL - TRIM AND SHEET NUMBER 3" = 1'0" COMPONENTS - INSTALL CONDITION 3" = 1'0" CLADDING COMPONENTS - INSTALL CONDITION 4 . 10 MA 4.00 Wall Opening Details-Touchstone Townhomes.dwg MA 4.00 Wall Opening Details-Touchstone Townhomes.dwg 4. 11 NOTE: NOTES: FORENSIC 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED WALL ASSEMBLIES. 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED WALL ASSEMBLIES BUILDING r U N,N t F N,s 2. METAL THRU WALL FLASHING IS TO BE COMPLETE WITH UPTURNED ENDS AT TERMINATIONS AND 2. METAL THRU WALL FLASHING IS TO BE COMPLETE WITH UPTURNED ENDS AT TERMINATIONS AND 1582nd Drive,Suite 10 CONTINUOUS AROUND CORNERS. CONTINUOUS AROUND CORNERS Gladstone,OR 97027 3. AT DYNAMIC SEALANT JOINTS, MAINTAIN JOINT DEPTH AT ONE HALF JOINT WIDTH. TEL 503.772.1114 3. THREE-DIMENSIONAL DRAWINGS ARE INTENDED TO ILLUSTRATE SPECIFIC CONCEPTS OF FAX 503.772.4039 4. ENSURE INSTALLED COMPONENTS ARE NOT VISIBLE BELOW SIDING AND/OR TRIM. COMPONENTS INSTALLATION. NOT ALL ASSEMBLY COMPONENTS ARE SHOWN www.forensicbuilding.com 5. DETAIL 4.04 SHOWS CONCEALED WINDOW JAMB INSTALLATION ASSEMBLY, REFER TO DETAIL 4.06 FOR info@forensicbuilding.corn TRIM AND CLADDING COMPONENTS. COPYRIGHT O2017 FORENSIC 6. DETAIL4.10 SHOWS CONCEALED WINDOW SILL INSTALLATION ASSEMBLY, REFER TO DETAI1I.11 AND BUTAll IRghtsR ReservNG ed 4.12 FOR TRIM AND CLADDING COMPONENTS. OR CCB#155496 WA FORENW C94308 UT#8334529-5501 N SLOPE \ PRESSURE TREATED FURRING STRIPS FIBER CEMENT PLANK LAP CLADDING V.I.F. LI 1/2.. 1/2"UPTURNED END DAM - FLUSH \ W/OUTSIDE FACE OF TRIM V.I.F. 24-GAUGE PRE-FINISHED METAL HEAD FLASHING OVER FURRING r 71011 FIBER CEMENT TRIM INTERIOR FILLET BEAD I PRINT ALL DETAILS IN OF SEALANT TYP COLOR AT 11X17 24 GAUGE PRE t 1 \ FINISHED METAL CLIENT INTERIOR SILL TRIM II HEAD FLASHING- TO MATCH EXISTIN ( (FA' I i``—' THROUGH-WALL Association of Unit 4'411;‘1DYNAMIC SEALANT JOINT(TYP.) CONTINUOUS Owners of Touchstone SEALANT 11 Townhomes \� :IIIn 1/2" BEAD 11 \ _ __ ISSUE \yy 24 GAUGE PRE FINISHED METAL ' I FLASHING WITH HEMMED DRIP EDGE �� 06.05.2018 AND DOWN TURNED END DAMS SET `I IN CONTINUOUS BEAD OF SEALANT Construction Issue Set z INTERIOR TRIM • / REVISIONS • CONTINUOUS I CONTINUOUS FILLET BEAD OF SEALANT REV. DATE PLYWOOD SHI Ie oill SCHEDULED TRIM, RABBET BOTTOM • OF TRIM FOR INTEGRATION OF FIBER MIN. M ISI CEMENT CLADDING (NOTE: JAMB TRIM WILL TERMINATE TO TOP SURFACE OF - 1 METAL FLASHING TYPICAL EACH SIDE)- WIDTH OF TRIM TO BE FLUSH WITH i JAMB TRIM- SIZE PER SPECIFICATIONS 1' PROJECT NAME - PRIME PRIOR TO SEALANT INSTALLATION (TYP) DYNAMIC SEALANT JOINT Touchstone Townhomes Targeted Building CONTINUOUS FILLET BEAD OF SEALANT Enclosure Rehabilitation FIBER CEMENT PLANK LAP CLADDING PROJECT NUMBER (FIBER CEMENT SHINGLE PANEL AND FIBER CEMENT PANEL CLADDING (R) 17-091 SIMILAR) SEALANT SHEET NAME '= WALL OPENING DETAILS 4. 12 WINDOW SILL - AT ALTERNATE TRIM 4. 13 WINDOW HEAD CLADDING JOINTS SHEET NUMBER 3" = 1'0" CONFIGURATION AND CLADDING COMPONENTS - INSTALL CONDITION 1 1/2" = 1'0" AT FIBER CEMENT LAP CLADDING - ISOMETRIC DETAIL 4. 12 MA 4.00 Wall Opening Details-Touchstone Townhomes.dwg MA 4.00 Wall Opening Details-Touchstone Townhomes.dwg 4. 13 REMOVE EXISTING EXAMPLE OF EXISTING OBSERVED CONDITION. FORENSIC 15 CLADDING AND TRIM TO PHOTO DOES NOT REPRESENT COMPLETE a°'`o i c W 5 a<< w ALLOW ACCESS OF SLIDING SCOPE OR VARIATIONS OF CONDITIONS. 1582nd Drive,Suite 10 Gladstone,OR 97027 -- TEL 503.772.1114 GLASS DOOR AND DECK i' FAX 503.772.4039 ASSEMBLY COMPONENTS. _ �. * CLADDING COMPONENTS BELOW DECK www.forensicbuilding.com — _ ,_ info@forensicbuilding.com SURFACE NOT SHOWN FOR CLARITY. ":'2'1:2.: COPYRIGHT©2017 FORENSIC x ISOMETRIC SEQUENCE REPRESENTS V FAX CONSULTANTS SGD INSTALL ONLY. "" — c All Rights Reserved OR CCB#155496 �i .��1(T ��� ali WA FORENW 094308 " •���' � �`'' ` UT#8334529-5501 Y rri W 444 AL 111,1 .',,,, ,.,„,-. _r ,,,, _._ ., , ,.. ,. _',7 , .. . ,..1110. INSTALL CONTINUOUS DECAY- *ENSURE R.O. IS RESISTANT SHIM AT SILL PLUMB AND LEVEL PRIOR TO SAM INSTALL WRB, EXTEND UP WITH SAM INSTALLATION BEHIND LEDGER AND LAP OVER PRINT ALL DETAILS IN METAL THRU-WALL FLASHING 2" MIN. COLOR AT 11x17 INSTALL SAM SILL CLIENT UNDERLAYMENT- 3/8"CONTINUOUS SEALANT PATCH AND REMOVE LEDGER TO INSTALL WRB BEDDING ON LEDGER Association of Unit PROPERLY LAP AND FLASHING COMPONENTS Owners of Touchstone ANY CORNER ABOVE AND BELOW DECK SURFACE Townhomes VOIDS,TYP. INSTALL PRESSURE TREATED INSTALL 24 GAUGE LEDGER TO RUN FLUSH WITH TOP ISSUE STAINLESS STEEL BASE SURFACE OF DECK BOARDS, SEE 06.05.2018 FLASHING- FASTEN NEXT STEPS / THROUGH VERTICAL / Construction Issue Set LEG ONLY REVISIONS / REV. DATE r / INSTALL 24-GAUGE / PRE-FINISHED METALV.I.F. .1. - '''''..-'."-•41 NI Lhi 41.I I I I III I I I I I*0‘.,THRU WALL FLASHING FASTEN THROUGH ;£ / VERTICAL LEG ONLY 1" , , ell 411$1 5" PROJECT NAME INSTALL WRB, EXTEND TO BOTTOM OF MIN THRU-WALL FLASHING 01 Touchstone Townhomes NO HEM OR KICK Targeted Building SAM INSTALLED BEHIND DECK LEDGER 6" Enclosure Rehabilitation AND BOTH TOP AND BOTTOM METAL LEDGER FLASHINGS. LAP OVER WRB PROJECT NUMBER J/ BELOW 2"MIN, TYP. (R) 17-091 SHEET NAME STEP 1 STEP 2 NOTE: 1. ISOMETRIC DETAILS ARE TO CONVEY INTENT ONLY. NOT ALL CONDITIONS ARE SHOWN. WALL OPENING 2. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED WALL DETAILS ASSEMBLIES. 3. METAL THRU WALL FLASHING IS TO BE COMPLETE WITH UPTURNED ENDS AT TERMINATIONS AND SHEET NUMBER 4. 14A SLIDING GLASS DOOR INSTALL CONTINUOUS AROUND CORNERS. 4. TREAT ALL CUT EDGES OF PRESSURE-TREATED LUMBER INCLUDING KERF CUTS WITH 1/2" = 1'0" AT F.C. CLADDING AND FLOW-THRU DECK ASSEMBLY- ISO. SEQ. 1 OF 4 COMPATIBLE TREATMENT SOLUTION PER AMERICAN WOOD PROTECTION ASSOCIATION- 4. 14A MA 4.00 Wall Opening Details-Touchstone Townhomes.dwg AWPA-M4. 5. REFER TO RELEVANT DETAILS FOR SILL, JAMB, AND HEAD FLASHING FOR SLIDING GLASS DOORS. FJRENSIC 8JI101,' CONSOS(ANSS 15 82nd Drive,Suite 10 Gladstone,OR 97027 ' TEL 503.7721114 FAX 503.772.4039 www.forens icbuilding.com ,,. info@forensicbuilding.com INSTALL WRB, LAP 2"MIN. OVER / COPYRIGHT 02017 FORENSIC BUILDING CONSULTANTS VERTICAL LEG OF DECK LEDGER All Rights Reserved OR CCB#155496 � FLASHING BELOW AND RUN WAFORENWC94308 PAST ROUGH OPENING AT DOOR UT#8334529-5501 HEAD- SEAL OR TAPE ALL EDGES AND CUTS. t 14 INSTALL 9" BUTYL BASED SAM OVER 1/2" WRB AT JAMBS, WRAPPING SAM 5,. AROUND CORNER AT R.O. PRINT ALL DETAILS IN COLOR AT 11x17 CLIENT 6"V.I.FF ` K SEAL LAP ONTO WRB BELOW Association of Unit 3' Owners of Touchstone Townhomes -,----.- ,. / ISSUE 06.052018 • C:Tto ruction Issue Set / � REVISINS RDATE ;•••/. �. • INSTALL 2 BEADS SEALANT AT BACK - <%� DAM OF SILL PAN <4 , INSTALL DECAY RESISTANT SHIMS INSTALL 24 GAUGE FULLY SOLDERED SILL, 8"O.C.TYP. REFER TO STAINLESS STEEL SILL PAN WITH 4" MANUFACTURER INSTRUCTIONS PROJECT NAME MIN. END DAMS OVER BASE OF WALL FLASHING AND SLOPE TO DRAIN Touchstone Townhomes Targeted Building SEALANT Enclosure Rehabilitation PROJECT NUMBER /! (R) 17-091 SHEET NAME STEP 3 STEP 4 WALL OPENING DETAILS 4. 14B SLIDING GLASS DOOR INSTALL SHEET NUMBER 1/2" = 1'0" AT F.C. CLADDING AND FLOW-THRU DECK ASSEMBLY- ISO. SEQ. 2 OF 4 4, 146 MA 4.00 Wall Opening Details-Touchstone Townhomes.dwg FORENSIC IUltIlIl tONSVLIAN1S 5 82nd Drive, APPLY MINIMALLY EXPANDING Gladstone,1 OR Suite 7027 SPRAY FOAM AFTER DOOR IS TEL 503.772.1114 INSTALLED, IF ACCESSIBLE AT INSTALL 9" BUTYL BASED SAMFAX:503.772.4039 www.forens icbu i Id i ng.corn DOOR HEISNEEDEDAT D TYP. FLASHING ALONG THE SGD HEAD info@forensicbuilding.com OVER SAM, DOOR FLANGE AND COPYRIGHT©2017 FORENSIC HEAD FLASHING BELOW BUILDING CONSULTANTS All Rights Reserved 1 1 OR CCB#155496 1 1: WUT 833 529 94308 501 INSTALL JAMBS 4 4 ill \ I \ I II.1 'wPRINT ALL DETAILS IN COLOR AT 11x17 // I CLIENT /// INSTALL 9"BUTYL BASED Association of Unit SAM AT JAMBS, OVERLAP Owners of Touchstone / DOOR FRAME ASSEMBLY.1 // • Townhomes . ISSUE � 06.05.2018 1 Construction Issue Set Iip \ ,,, ! � REVISIONS �, REV. DATE 61 1 ,_, 1 III ��► PROJECT NAME \ Touchstone Townhomes Targeted Building PROVIDE CONTINUOUS BEAD O\ Enclosure Rehabilitation SEALANT ALONG JAMB, JUST ABOVE ' SILL JUNCTURE,AND AT BACKSIDE OF / PROJECT NUMBER WINDOW FRAME TO INTERSECT WITH INSTALL SGD INTERIOR FINISH FOR AIR SEAL ASSEMBLY (R) 17-091 SHEET NAME STEP 5 DO NOT APPLY SEALANT ALONG STEP 6 WALL OPENING BACK SIDE OF FLANGE AT WINDOW DETAILS SILL- SEE SILL SECTION DETAIL 4. 14C SLIDING GLASS DOOR INSTALL SHEET NUMBER 1/2" = 1'0" AT F.C. CLADDING AND FLOW-THRU DECK ASSEMBLY- ISO. SEQ. 3 OF 4 4. 14C MA 4.00 Wall Opening Details-Touchstone Townhomes.dwg FORENSIC BUILDING rUMSUL(f N15 15 82nd Drive,Suite 10 / Gladstone,OR 97027 —— . TEL 503.772.1114 FAX 3 772 //� FAX \ www.forens cbu dinngcom ../ / / \ info@forensicbuilding.com / / COPYRIGHT©2017 FORENSIC /// ' // I BUILDING CONSULTANTS ' All Rights Reserved /_ / / OR CCB#155496 j WA FORENW C94308 / \\\ / '44111,111, i UT#8334529-5501 / �_�!------- INSTALL WRB, LAP OVER LOWER i,,,T LAYER AND METAL HEAD FLASHING 2"MIN.AND SEAL INSTALL METAL HEAD FLASHING WITH UPTURNED END DAMS ALONG THE DOOR PRINT ALL DETAILS IN HEAD, SET ON CONT. 3/8" FIBER CEMENT CLADDING COLOR AT 11x17 BEAD OF SEALANT. � AND TRIM NOT SHOWN CLIENT Association of Unit Owners of Touchstone Townhomes ISSUE 06.05.2018 • I ,I 4 ' � � :St: 5et 4TE DO NOT PENETRATE li FLASHING WITH DECK BOARD FASTENERS Ili 4 44 - 1 ,... 4 4 NOTCH DECK BOARD �� 4 �`- INSTALL SCHEDULED DECK ��• TO ADMIT FLASHING BOARDS MATCHING EXISTING PROJECT NAME AS NEEDED ORIENTATION WITH 1/4"CLEAR SPACING BETWEEN Touchstone Townhomes Targeted Building Enclosure Rehabilitation INSTALL DECK JOIST AND FRAMING WITH 'Z-MAX' CONNECTION HARDWARE PROJECT NUMBER (R) 17-091 SHEET NAME STEP 7 STEP 8 WALL OPENING DETAILS 4. 14D SLIDING GLASS DOOR INSTALL " REINSTALL INTERIOR TRIM COMPONENTS, REPLACE DAMAGED SHEET NUMBER 1/2" = 1'0" AT F.C. CLADDING AND FLOW-THRU DECK ASSEMBLY- ISO. SEQ. 4 OF 4 TRIM WITH LIKE KIND AND FINISH TO MATCH EXISTING. MA 4.00 Wall Opening Details-Touchstone Townhomes.dwg *CLADDING, TRIM,AND ADDITIONAL FLASHING NOT SHOWN FOR 4. 14D CLARITY. NOTES: 1. ISOMETRIC DETAILS ARE TO CONVEY INTENT ONLY. NOT ALL CONDITIONS ARE SHOWN. EXAMPLE OF EXISTING OBSERVED CONDITION. FORENSIC e 2. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED WALL ASSEMBLIES. PHOTO DOES NOT REPRESENT COMPLETE i o i C o w i�.i s SCOPE OR VARIATIONS OF CONDITIONS. 15 adst neOR Suite 97027 3. METAL THRU WALL FLASHING IS TO BE COMPLETE WITH UPTURNED ENDS AT TERMINATIONS AND Gladstone,Drive, 10 CONTINUOUS AROUND CORNERS. TEL��`�4`, TEL 503.772.1114 FAX:503.772.4039 4. VERIFY THAT ALL DECK SURFACES ARE RE-SLOPED TO DRAIN AT 2%. ' wwFAX'5 3 772. 039om 5. MECHANICALLY FASTEN BASE FLASHING AS REQUIRED BY DETAILS AND MANUFACTURERS REQUIREMENTS. into@forenslcbuilding.corn 6. VERIFY ADEQUATE ADHESION OF CEMENTITIOUS DECK COATING TO SHEATHING AND BASE OF WALL AND COPYRIGHT C2017 FORENSIC SILL PAN FLASHINGS PRIOR TO APPLICATION. '` BUILDING CONSULTANTS t14 N All Rights Reserved 7. INSTALL CEMENTITIOUS DECK COATING SYSTEM IN CONFORMANCE WITH MANUFACTURER'S jt �I`',��� 111111 y�:'t OR CCB#155496 INSTRUCTIONS. LAP AND SEAL METAL FLASHING IN CONFORMANCE WITH PROJECT DOCUMENTS. , WAFORENWC94306 8. REFER TO RELEVANT DETAILS FOR SILL, JAMB,AND HEAD FLASHING FOR SLIDING GLASS DOORS. UT#8334529-5501 f -- to MN ■/ REMOVE EXISTING CLADDING AND TRIM TO ALLOW ACCESS OF SLIDING GLASS DOOR AND DECK ASSEMBLY COMPONENTS. PRINT ALL DETAILS IN COLOR AT 11x17 CLIENT Association of Unit Owners of Touchstone Townhomes *EPLUNSUREMBANDLR.O. ISEVEL ISSUE PRIOR TO SAM 06.05.2018 INSTALLATION SEAL ALL METAL Construction Issue Set INSTALL CONTINUOUS FLASHING LAPS, REVISIONS INSTALL CONTINUOUS SEALANT AT BOTTOM REF DETAIL6.XX REV. DATE DECAY-RESISTANT SHIM FLANGE (AT CONDITION AT SILL WHERE R.O. IS NOT 0/1 2 " PRESENT) 4"�� 1 0 1l2" 1100IPIIIIIIIIh- PROJECT NAME / '-- f' :.'' ':''' 5" I Touchstone Townhomes )1/4001011111/0" Targeted Building Enclosure Rehabilitation APPLY SHEET MEMBRANE, EXTEND 6"_ / PROJECT NUMBER Jr INSTALL 24-GAUGE FULLY VERTICALLY MIN. 8" UP WALL AND 24-GAUGE BONDERIZED METAL SOLDERED STAINLESS STEEL (R) 17-091 JAMBS OF THE R.O.AND LAP INTO BASE OF WALL FLASHING SILL PAN WITH 4" MIN. END DAMS THE SILL OVER BASE OF WALL FLASHING STEP 1 STEP 2 STEP 3 SHEET NAME AND SLOPE TO DRAIN WALL OPENING DETAILS 4. 15A SLIDING GLASS DOOR INSTALL SHEET NUMBER 1/2" = 1'0" AT F.C. CLADDING AND WATERPROOF DECK ASSEMBLY- ISO. SEQ. 1 OF 4 4.15A MA 4.00 Wall Opening Details-Touchstone Townhomes.dwg FORENSIC BUI101 NG IGN SlIl I ANIS 15 82nd Drive,Suite 10 Gladstone,OR 97027 TEL 503.772.1114 FAX 503.772.4039 www.forensicbui lding.com info@forensicbuilding.corn COPYRIGHT©2017 FORENSIC BUILDING CONSULTANTS All Rights Reserved OR CCB#155496 WA FORENW C94308 UT#8334529-5501 WRAP SAM AROUND CORNER AT HEAD, PATCH CORNER VOID INA !. WATERSHED FASHION�,_ PRINT ALL DETAILS IN COLOR AT 11x17 CLIENT INSTALL WRB Association of Unit Owners of Touchstone Townhomes ISSUE 06.05.2018 I Construction Issue Set 9"STRIP OF SAM FLASHING t ALONG BOTH JAMBS AND REVISIONS AROUND CORNER AT HEAD REV. DATE OF THE ROUGH OPENINGS. . 00 \=11' ;i /l4 1 1 / PROJECT NAME Touchstone Townhomes 0.441*: Targeted Building INSTALL 2 BEADS SEALANT Enclosure Rehabilitation AT BACK DAM OF SILL PAN PROJECT NUMBER INSTALL DECK COATING- PREP (R) 17-091 SURFACE AS REQUIREDSEAL WRB TO BASE OF INSTALL DECAY RESISTANT WALL FLASHING STEP 6 SHIMS SILL, 8"O.C.TYP. STEP 4 STEP 5 REFER TO MANUFACTURER SHEET NAME INSTRUCTIONS WALL OPENING DETAILS 4. 15B SLIDING GLASS DOOR INSTALL SHEET NUMBER 1/2" = 1'0" AT F.C. CLADDING AND WATERPROOF DECK ASSEMBLY- ISO. SEQ. 2 OF 4 4. 156 MA 4.00 Wall Opening Details-Touchstone Townhomes.dwg FORENSIC e u i L o l u u r o N e o I A N 1 5 15 82nd Drive,Suite 10 APPLY MINIMALLY EXPANDING Gladstone,OR 97027 SPRAY FOAM AFTER DOOR IS TEL 503.772.1114 FAX 503.772.4039 INSTALLED, IF ACCESSIBLE AT www.farensicbuilding.com DOOR HEAD TYP. info@forensicbuilding.com COPYRIGHT©2017 FORENSIC BUILDING CONSULTANTS All Rights Reserved OR CCB#155496 WA FORENW C94308 UT#8334529-5501 INSTALL SHIMS AS NEEDED AT JAMBS INSTALL 9"BUTYL BASED SAM FLASHING ALONG THE SGD HEAD OVER SAM, DOOR FLANGE 1 .11i j I PRINT ALL DETAILS IN J11COLOR AT 11x17 \ ''1,1 CLIENT / Association of Unit / , '1 Owners of Townhomesstone r' 01 / ISSUE 06.05.2018 Construction Issue Set REVISIONS REV. DATE 04* INSTALL 9" BUTYL BASED SAM AT JAMBS. h I / i STEP 7 11 PROJECT NAME \ � Touchstone Townhomes PROVIDE CONTINUOUS BEAD OF JjTargeted Building SEALANT ALONG JAMB, JUST ABOVE ' Enclosure Rehabilitation SILL JUNCTURE,AND AT BACKSIDE OF PROJECT NUMBER WINDOW FRAME TO INTERSECT WITH INSTALL SGD INTERIOR FINISH FOR AIR SEAL ASSEMBLY (R) 17-091 SHEET NAME DO NOT APPLY SEALANT ALONG WALL OPENING BACK SIDE OF FLANGE AT WINDOW DETAILS SILL-SEE SILL SECTION DETAIL STEP 8 4. 15C SLIDING GLASS DOOR INSTALL SHEET NUMBER 1/2" = 1'0" AT F.C. CLADDING AND WATERPROOF DECK ASSEMBLY- ISO. SEQ. 3 OF 4 4. 15C MA 4.00 Wall Opening Details-Touchstone Townhomes.dwg FORENSIC 11111116 [OYSO61AYIS 15 82nd Drive,Suite 10 Gladstone,OR 97027 TEL 503.772.1114 FAX 503.772.4039 wwwforens icbuilding.com info@forensicbuilding.corn COPYRIGHT @2017 FORENSIC BUILDING CONSULTANTS All Rights Reserved OR CCB#155496 WA FORENW C94308 UT#8334529-5501 / ' I / I ' / /�044001 \ / �' PRINT ALL DETAILS IN COLOR AT 11x17 _ INSTALL WRB, LAP OVER LOWER LAYER AND METAL HEAD CLIENT �<< FLASHING 2" MIN.AND SEAL Association of Unit --te a i V / / Owners of Touchstone Townhomes ISSUE INSTALL METAL HEAD FLASHING 06.05.2018 WITH UPTURNED END DAMS ALONG THE DOOR HEAD, SET ON Construction Issue Set CONT. 3/8" BEAD OF SEALANT. REVISIONS REV. DATE J)L � PROJECT NAME Touchstone Townhomes Targeted Building jEnclosure Rehabilitation PROJECT NUMBER (R) 17-091 SHEET NAME STEP 9 STEP 10 WALL OPENING DETAILS 4. 15D SLIDING GLASS DOOR INSTALL * REINSTALL INTERIOR TRIM COMPONENTS, REPLACE DAMAGED SHEET NUMBER 1/2" = 1011 AT F.C. CLADDING AND WATERPROOF DECK ASSEMBLY- ISO. SEQ. 4 OF 4 TRIM WITH LIKE KIND AND FINISH TO MATCH EXISTING. MA 4.00 Wall Opening Details-Touchstone Townhomes.dwg * CLADDING, TRIM,AND ADDITIONAL FLASHING NOT SHOWN FOR 4. 15D CLARITY. NOTES: FORENSIC 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED WALL ASSEMBLIES. I IiM 1 5 2. CONTRACTOR TO ENSURE TRIM AND FLASHING COMPONENTS DO NOT INTERFERE WITH DOOR OPERATION. 15 82nd Drive,Suite 10 3. METAL THRU WALL FLASHING IS TO BE COMPLETE WITH UPTURNED ENDS AT TERMINATIONS AND Gladstone,OR97027 TEL:503.772.1114 CONTINUOUS AROUND CORNERS. FAX 503.772.4039 4. AT DYNAMIC SEALANT JOINTS, MAINTAIN JOINT DEPTH AT ONE HALF JOINT WIDTH. www.forensicbuilding.corn 5. TRIM AND SIDING TO BE INSTALLED IN CONFORMANCE WITH MANUFACTURER'S INSTRUCTIONS. nfo@forensicbullding.com 6. INSTALL FILLET BEAD OF SEALANT IF ABUTTING COMPONENTS ARE TOUCHING OR ARE LESS THAN 1/4"APART.IF COPYRIGHT©2017 FORENSIC BUILDING CONSULTANTS GAP IS 1/4"TO LESS THAN 1/2"INSTALL LOW EXPANDING FOAM.IF GAP IS 1/2"OR LARGER INSTALL BACKER ROD \ All Rights Reserved AND SEALANT. 155496 WA FORENW C94308 PLYWOOD SHEATHING UT#8334529-5501 Imp 41. 11...111110 SCHEDULED WRB, LAP OVER FLASHING AND 5% MIN SLOPE SAM COMPONENTS BELOW 1/2• " 1/2" I,iiiiie I PRESSURE TREATED FURRING STRIP WITH 1/2 INSECT SCREEN AT HORIZ. TERMINATIONS, I TYP. CONTINUOUS BEAD OF FIBER CEMENT PLANK LAP CLADDING SEALANT BEHIND SGD FLANGE AT HEAD AND JAMBS PRINT ALL DETAILS IN SCHEDULED FIBER CEMENT-) TRIM, PRIME PRESSURE TREATED COLOR AT 11x17 iftili . PRIOR TO SEALANT INSTALLATION FURRING STRIPS CLIENT DYNAMIC SEALANT JOINT 4111,0000.. ' 9"BUTYL BASED SAM, EXTEND DOWN AND FILLET BEAD OF SEALANT Association of Unit .. ,4iiillp , OVER SGD FLANGE BELOW INSTALLED SLIDING GLASS DOOR FIBER CEMENT LAP Owners of Touchstone I CONTINUOUS BEAD OF SEALANT FOR ASSEMBLY1 II CLADDING Townhomes 1/2" . i°) I 1 001) AIR SEAL �/ 9" BUTYL BASED SAM ISSUE I II e • • • 06.05.2018 • 24 GAUGE PRE FINISHED METAL HEAD G = G = =1 Construction Issue Set FLASHING (TYP)WITH UP TURNED END REVISIONS w DAMS AND HEMMED DRIP EDGE SET ON ) 1 9„ ,., REV. I DATE 1/2" CONTINUOUS 3/8"BEAD OF SEALANT 6" Ili 1 \ : ilitt - SCHEDULED TRIM- SIZE PER r "' 2" SPECIFICATIONS- PRIME PRIOR TO SEALANT �o c 9" INSTALLATION (TYP.) \ CONTINUOUS BEAD OF SEALANT BEHIND �� � SLIDING GLASS DOOR FLANGE 1/2" INTERIOR BEAD \ Er OF SEALANT . _ PROJECT NAME q_ ---- 11 Touchstone Townhomes clpi___ 24-GAUGE PRE-FINISHED METAL INTERIOR BEAD o� o', THRU-WALL FLASHING WITH END DAMS Targeted Building WRB Enclosure Rehabilitation OF SEALANT --D AND HEMMED DRIP EDGE SET ON l� CONTINUOUS 3/8"BEAD OF SEALANT PROJECT NUMBER PLYWOOD SHEATHING (R) 17-091 INSTALLED SLIDING GLASS DOOR ASSEMBLY SHEET NAME WALL OPENING DETAILS 4. 16 TYPICAL SLIDING GLASS DOOR HEAD 4. 17 TYPICAL SLIDING GLASS DOOR JAMB SHEET NUMBER 3" = 1'0" AT FIBER CEMENT CLADDING - INSTALL CONDITION 3" = 1'0" AT FIBER CEMENT CLADDING - INSTALL CONDITION 4. 16 MA 4.00 Wall Opening Details-Touchstone Townhomes.dwg MA 4.00 Wall Opening Details-Touchstone Townhomes.dwg 4. 17 NOTES: NOTES: FORENSIC 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED WALL ASSEMBLIES 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED WALL ASSEMBLIES. IG LUIIWIANIS 2. CONTRACTOR TO ENSURE TRIM AND FLASHING COMPONENTS DO NOT INTERFERE WITH DOOR OPERATION. 2. CONTRACTOR TO ENSURE TRIM AND FLASHING COMPONENTS DO NOT INTERFERE WITH DOOR OPERATION. 1582nd Drive,Suite 10 3. TRIM TO TUCK UNDER THRU-WALL FLASHING WHERE APPLICABLE 3. VERIFY THAT ALL DECK SURFACES ARE SLOPED TO DRAIN MINIMUM 2%. NOTIFY CONSULTANT IF SLOPE Gladstone,OR 97027 TEL:503.772.1114 4. SHEET METAL FLASHING IS TO FULLY COVER SAM FROM ALL UV EXPOSURE. IS REVERSED OR INADEQUATE. FAX 503.772.4039 5. TREAT ALL CUT EDGES AT PRESSURE-TREATED LUMBER WITH COMPATIBLE TREATMENT SOLUTION PER 4. MECHANICALLY FASTEN BASE FLASHING AS REQUIRED BY DETAILS AND MANUFACTURER'S www.forensicbuilding.com info@forensicbuilding.com AMERICAN WOOD PROTECTION ASSOCIATION-AWPA-M4. REQUIREMENTS. COPYRIGHT @2017 FORENSIC 6. INSTALL FILLET BEAD OF SEALANT IF ABUTTING COMPONENTS ARE TOUCHING OR ARE LESS THAN 1/4"APART. 5. DO NOT INSTALL FASTENERS THROUGH HORIZONTAL SURFACE OF SILL PAN. BUILDING CONSULTANTS IF GAP IS 1/4"TO LESS THAN 1/2"INSTALL LOW EXPANDING FOAM.IF GAP IS 1/2"OR LARGER INSTALL BACKER 6. VERIFY ADEQUATE ADHESION OF NEW WP40 SHEET MEMBRANE, PRIOR TO APPLICATION. INSTALL All Rights Reserved ROD AND SEALANT CEMENTITIOUS DECK COATING SYSTEM IN CONFORMANCE WITH MANUFACTURER'S INSTRUCTIONS. LAP OR CCB#155496 WA FORENW C94308 7. MECHANICALLY FASTEN BASE FLASHING AS REQUIRED BY DETAILS AND MANUFACTURER'S REQUIREMENTS. AND SEAL METAL FLASHING IN CONFORMANCE WITH PROJECT DOCUMENTS. UT#8334529-5501 8. DO NOT INSTALL FASTENERS THROUGH HORIZONTAL SURFACE OF SILL PAN. 7. REMOVE TILE, TILE ADHESIVE, EXISTING DECK SHEATHING MATERIALS FROM DECK AREAS. INSTALL NEW SHEATHING TO RECEIVE CEMENTITIOUS DECK COATING. PROVIDE CLEAN SURFACE FOR SAM PAN WITH 6" END DAMS OVER CONTINUOUS APPLICATION AND FINISH TO MEET MANUFACTURER'S APPLICATION REQUIREMENTS. SHIM DECAY-RESISTANT SHIMS TO PROVIDE LEVEL SUPPORT AT SILL SOLDERED END INSTALLED SLIDING GLASS 1 1/2" DOOR ASSEMBLY ! CONTINUOUS SHIM AS REQUIRED TO NEGATE ANY MIN. DAM BEYOND REVERSE SLOPING OR PONDING AT DOOR SILL N44"24-GAUGE FULLY SOLDERED STAINLESS STEEL 4 o V.I.F. XSILL PAN WITH UP-TURNED END DAMS, SLOPE TO 5/o MIN SLOPE 11" 2 BEADS SEALANT - DRAIN • w• 1/2" if,1/2, VIF `{` 1/2 \ PRINT ALL DETAILS IN TO COMPLETE AIR WRB TO EXTEND OVER THRU-WALL FLASHING 1/2" 2' COLOR AT 11x17 SEAL BELOW JI� "'�II 24-GAUGE STAINLESS STEEL FLASHING-FASTEN MIN. CLIENT THRESHOLD 4 j� THROUGH UP-LEG ONLY,OVERLAP WITH SILL • MIN. i°`�I�II� 1�i PAN, SET IN BED OF SEALANT 1 SAM PAN WITH 6" END DAMS OVER Association of Unit INTERIOR 1111._,�Q r� Owners of Touchstone FINISH CONTINUOUS SHIM �r L''�i�l END DAM BEYOND knit INSTALLED SLIDING GLASS Townhomes q. "/, .11.1 SCHEDULED DECK BOARDS PER DOOR ASSEMBLY DECAY-RESISTANT SHIMS TO PROVIDE LEVEL r - ==j SUPPORT AT SILL ISSUE SPECIFICATIONS, NOTCH TO ADMIT FLASHING AS NEEDED CONTINUOUS SHIM AS REQUIRED TO NEGATE 06.05.2018 2,, = ANY REVERSE SLOPING OR PONDING AT MIN.III 1/4" DOOR SILL Construction Issue Set � TYP. I 2 BEADS SEALANT 24-GAUGE FULLY SOLDERED STAINLESS REVISIONS I 7i��(I //�' • `��/I�% %//� TO COMPLETE AIR STEEL SILL PAN WITH UP-TURNED END DAMS, �il \ h�� //� �� / % ���� \ r —� I SLOPE TO DRAIN REV. DATE II SEAL BELOW 4" 1 • �������'���'��"� ��� // �I/�i��, THRESHOLDI, i. r SEALANT PER COATING MANUFACTURER 1.. MIN. ��I IIII11/11**111 INTERIOR j -1T�� WP40 SHEET MEMBRANE, EXTEND INTO SILL FINISHN ��rz7 m�I� il AND VERTICALLY UP WALL MIN. 2" BEYOND nnurIiEIIfrU IiII+fIIII7nnu�l'J�eeii/IEiftt'L �ne!✓i✓v��� I'�1 i mlI i }. h FLASHING LEG 2.. ( CONTINUOUS BEAD OF SEALANT FOR 1/2 n.. ��' AIR SEAL . ACRYLIC CEMENTITIOUS REINFORCED 2%SLOPE I MIN I ' o DECK COATING SYSTEM TO DRAIN I- SCHEDULED LAG BOLTS AS x�inri�r7rnrn✓��auuirenN�sri,ui.. ., .. i,,,r ni�rat•■ I i% %//i%� i/ - '—-•/ice'//'/// //•-•//•-••//•; . �.. /, REQUIRED- FILL AND SEAL HOLES PROJECT NAME , ,,r_ --\/ XISTING� / / / / i SUBSTRATE' Touchstone Townhomes I i DECK LEDGER TO REMAIN 3„ ALTERNATE THIN SET TILE Targeted Building 2 24 GAUGE PRE FINISHED THRU WALL FLASHING INDICATED OVER MORTAR Enclosure Rehabilitation I BED (NOT BASE SCOPE OF 1 MIN. SET IN SEALANT WITH UP TURNED END DAMS WORK) PROJECT NUMBER AND HEMMED DRIP EDGE 0SAM, EXTEND TO TERMINATE ALONG EDGE OF ' REMOVE AND REPLACE (R) 17-091 R.O., LAP OVER WRB BELOW 2" MIN. PLYWOOD DECK SHEATHING - I FIBER CEMENT PLANK LAP CLADDING PRESSURE TREATED FURRING STRIP WITH 24 GAUGE GALVINZED METAL WALL OPENING BASE-OF-WALL FLASHING DETAILS PLYWOOD SHEATHING INSECT SCREEN AT HORIZ. TERMINATIONS, TYP. 4. 18 TYPICAL SLIDING GLASS DOOR SILL 4. 19 TYPICAL SLIDING GLASS DOOR SILL SHEET NUMBER 3" = 1'0" AT FLOW-THRU DECK ASSEMBLY- INSTALL CONDITION 3" = 1'0" AT WATERPROOF DECK ASSEMBLY- INSTALL CONDITION 4. 18 MA 4.00 Wall Opening Details-Touchstone Townhomes.dwg MA 4.00 Wall Opening Details-Touchstone Townhomes.dwg 4. 19 NOTE: EXAMPLE OF EXISTING OBSERVED CONDITION. FORENSIC 1. ISOMETRIC DETAILS ARE TO CONVEY INTENT ONLY. NOT ALL CONDITIONS ARE SHOWN. 2. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED WALL ASSEMBLIES. PHOTO DOES NOT REPRESENT COMPLETE g v[ w N z 3. METAL THRU WALL FLASHING IS TO BE COMPLETE WITH UPTURNED ENDS AT TERMINATIONS AND SCOPE OR VARIATIONS OF CONDITIONS. 1582nd Drive,Suite 10 Gladstone,OR 97027 CONTINUOUS AROUND CORNERS. TEL 503 772.1114 FAX 503.772.4039 4. VERIFY THAT ALL CONCRETE WALK SURFACES ARE SLOPED TO DRAIN MINIMUM 2%AWAY FROM fn wwwforensicbuilding ng.com corn BUILDING. NOTIFY CONSULTANT IF SLOPE IS REVERSED OR INADEQUATE. 5. REFER TO RELEVANT DETAILS FOR SILL, JAMB,AND HEAD FLASHING FOR SWING DOORS. COPYRIGHT©2017 FORENSIC BUILDING CONSULTANTS ___r - •�,- All Rights Reserved OR CCB#155496 WA FORENW C94308 UT#8334529-5501 REMOVE EXISTING7 CLADDING AND TRIM TO ALLOW ACCESS OF SWING ,,DOOR AND DECK ASSEMBLY i:, - p COMPONENTS. " �_.. i I 1 r �; PRINT ALL DETAILS IN r COLOR AT 11x17 CLIENT 4 4 ____________ t Association of Unit Owners of Touchstone Townhomes ISSUE INSTALL BASE OF WALL06.05.2018 SAM,WRAP INTO DOOR SEAL ALL METAL R.O.AND OVER FLASHING LAPS Construction Issue Set FURRING STRIP AT SILL REVISIONS ... 4" REV. DATE 14.. 6:\\ , • ypi 41 •)), .k EXISTING CONCRETE 5" STEP AND PATIO TO ' REMAIN 46"1- PROJECT NAME INSTALL CONTINUOUS INSTALL 24-GAUGE FULLY INSTALL WRB Touchstone Townhomes SOLDERED STAINLESS STEEL /00,SHIM SILL- ENSURE SILL PAN OVER CONTINUOUS Targeted Building NOT TOOREVERSE SLOPE SEAL WRB TO Enclosure Rehabilitation OR ALLOW PONDING SHIM. COVER SAM FROM UV EXPOSURE AT DOWNLEG, BASE-OF-WALL i PROJECT NUMBER � INSTALL PRESSURE �� TERMINATE WITH HEMMED FLASHING DRIP LEG. (R) 17-091 STEP 1 TREATED FURRING AS STEP 2 STEP 3 REQUIRED TO PROVIDE SUPPORT BEHIND SILL SHEET NAME PAN WALL OPENING DETAILS 4.20A SWING DOOR INSTALL - AT CONCRETE STEP SHEET NUMBER 1/2" = 1'0" AND FIBER CEMENT CLADDING - ISOMETRIC DETAIL SEQUENCE 1 OF 4 4.20A MA 4.00 Wall Opening Details-Touchstone Townhomes.dwg FORENSIC 6UILUIMO rOMM4lIAMIS 15 82nd Drive,Suite 10 Gladstone,OR 97027 TEL:503.772.1114 FAX:503.772.4039 www.forensicbuilding.com info@forensicbuilding.corn INSTALL SHIMS AS NEEDED COPYRIGHT©2017 FORENSIC AT JAMBS,APPLY BUILDING CONSULTANTS INSTALL A 9" MIN. BUTYL-BASED MINIMALLY EXPANDING All Rights Reserved SAM FLASHING ALONG THE SPRAY FOAM AFTER DOOR OR CCB#155496 INSTALL SWING DOOR WAFORENWC94308 SWING DOOR HEAD, IS INSTALLED ASSEMBLY UT#8334529-5501 WRAPPING UNDER AND INTO THE ROUGH OPENING ® C 1 .111 I PRINT ALL DETAILS IN COLOR AT 11x17 CLIENT Association of Unit Owners of Touchstone ' 9"STRIP OF Townhomes BUTYL-BASED SAM FLASHING ALONG ISSUE BOTH JAMBS AND AROUND CORNER AT06.05.2018 HEAD OF THE ROUGH m OPENINGS. PATCH Construction Issue Set CORNER VOID WITH REVISIONS SAM IN A WATERSHED REV. DATE FASHION 11 PROJECT NAME r INSTALL 2 BEADS Touchstone Townhomes SEALANT AT BACK Targeted Building DAM OF SILL PAN Enclosure Rehabilitation INSTALL DECAY-RESISTANT PROJECT NUMBER SHIMS TO PROVIDE LEVEL (R) 17-091 STEP 4 STEP 5 STEP 6 SUPPORT AT SILL, 8"O.C. OR AS REQUIRED BY MANUFACTURER TO PROVIDE NECESSARY SHEET NAME SUPPORT WALL OPENING DETAILS 4.20B SWING DOOR INSTALL - AT CONCRETE STEP SHEET NUMBER 1/2" = 1'0" AND FIBER CEMENT CLADDING - ISOMETRIC DETAIL SEQUENCE 2 OF 4 4.20B MA 4.00 Wall Opening Details-Touchstone Townhomes.dwg FORENSIC BUILDING tON SO1(ANOS 15 82nd Drive,Suite 10 Gladstone,OR 97027 TEL:503.772.1114 FAX:503.772.4039 www.forensicbuilding.com info@forensicbuilding.com COPYRIGHT©2017 FORENSIC BUILDING CONSULTANTS All Rights Reserved OR CCB#155496 /I WA FO 3 C94308 / j UT#8334529-5501 01 INSTALL 9" BUTYL INSTALL PRIMED PRINT ALL DETAILS IN BASED SAM AT HEAD CEDAR FURRING TO COLOR AT 11x17 MATCH THICKNESS CLIENT OF SCHEDULED Association of Unit j.... ''. FURRING AT JAMBS Owners of Touchstone AND HEAD THEN Townhomes SCHEDULED TRIM - INSTALL 9"BUTYL PRIME ALL END CUTS ISSUE BASED SAM FLASHING, 06.05.2018 LAP ONTO DOOR FRAME Construction Issue Set li REVISIONS REV. DATE 6 401#.1111111111 °° 1°1 PROJECT NAME Touchstone Townhomes Targeted Building Enclosure Rehabilitation / PROJECT NUMBER / STEP 7 STEP 8 STEP 9 (R) 17-091 SHEET NAME WALL OPENING DETAILS 4.20C SWING DOOR INSTALL - AT CONCRETE STEP SHEET NUMBER 1/2" = 1'0" AND FIBER CEMENT CLADDING - ISOMETRIC DETAIL SEQUENCE 3 OF 4 �I ,20C MA 4.00 Wall Opening Details-Touchstone Townhomes.dwg �F FORENSIC 81110111 1111111AN1S 15 82nd Drive,Suite 10 Gladstone,OR 97027 TEL:503.772.1114 FAX 503.772.4039 _ www.forensicbuilding.corn //moi \ info@forensicbuilding corn \ COPYRIGHT©2017 FORENSIC / \ BUILDING CONSULTANTS // / \ All Rights Reserved // I % / OR CCB#155496 ENW ` // I\ __ WA TF 8334 9-55 1 / 94308 INSTALL WRB, LAP OVER LOWER LAYER AND METAL HEAD FLASHING 111 2"MIN.AND SEAL 11 41 INSTALL METAL HEAD FLASHING PRINT ALL DETAILS IN WITH UPTURNED END DAMS COLOR AT 11x17 ALONG THE DOOR HEAD TRIM, SET CLIENT ON CONT. 3/8" BEAD OF SEALANT. Association of Unit Owners of Touchstone Townhomes ISSUE 06.05.2018 Construction Issue Set REVISIONS REV. DATE r 7 I PROJECT NAME Touchstone Townhomes Targeted Building Enclosure Rehabilitation PROJECT NUMBER (R) 17-091 STEP 10 STEP 11 SHEET NAME WALL OPENING DETAILS 4.20D SWING DOOR INSTALL - *AT CONCRETE STEP REINSTALL INTERIOR TRIM COMPONENTS, REPLACE DAMAGED SHEET NUMBER 1/2" = 1'0" AND FIBER CEMENT CLADDING - ISOMETRIC DETAIL SEQUENCE 4 OF 4 TRIM WITH LIKE KIND AND FINISH TO MATCH EXISTING. MA 4.00 Wall Opening Details-Touchstone Townhomes.dwg * CLADDING NOT SHOWN FOR CLARITY. 4.20D NOTES: FORENSIC 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED WALL ASSEMBLIES e tl I 1 8111 COISULIANISS 2. CONTRACTOR TO ENSURE NEW TRIM AND FLASHING COMPONENTS DO NOT INTERFERE WITH SWING DOOR OPERATION. 15 82nd Drive,Suite 10 3. METAL THRU WALL FLASHING IS TO BE COMPLETE WITH UPTURNED ENDS AT TERMINATIONS AND CONTINUOUS AROUND CORNERS Gladstone,OR 97027 4. AT DYNAMIC SEALANT JOINTS, MAINTAIN JOINT DEPTH AT ONE HALF JOINT WIDTH TEL:503.772.1114 FAX:503.772.4039 5. TRIM TO TUCK UNDER THRU-WALL FLASHING WHERE APPLICABLE www.forensicbuilding.corn 6. ENSURE INSTALLED CONCEALED COMPONENTS ARE NOT VISIBLE BELOW CLADDING AND/OR TRIM. info@forensicbuilding.com 7. INSTALL FILLET BEAD OF SEALANT IF ABUTTING COMPONENTS ARE TOUCHING OR ARE LESS THAN 1/4"APART. IF GAP IS 1/4"TO LESS COPYRIGHT©2017 FORENSIC THAN 1/2" INSTALL LOW EXPANDING FOAM. IF GAP IS 1/2"OR LARGER INSTALL BACKER ROD AND SEALANT BUILDING CONSULTANTS All Rights Reserved OR CCB#155496 WA FORENW C94308 UT#8334529-5501 EXISTING SHEATHING WRB, LAP OVER SAM FLASHING AND I! METAL HEAD FLASHING BELOW PRESSURE TREATED FURRING STRIPS 4 -'I -- , I WITH INSECT SCREEN AT HORIZ. 9" BUTYL BASED SAM, LAP ONTO -4IllIllillilli.I' . TERMINATIONS, TYP. DOOR FRAME FIBER CEMENT LAPPED CLADDING SEALANT FILLET BEAD P.T. FURRING STRIPS SCHEDULED TRIM-SIZE PER BUTYL BASED SAM, WRAP PRINT ALL DETAILS IN SPECIFICATIONS- PRIME INTO ROUGH OPENING COLOR AT 11x17 CONTINUOUS BEAD OF SEALANT PRIOR TO SEALANT FIBER CEMENT LAPPED CLIENT aimmow., . FOR AIR-SEAL INSTALLATION (TYP.) CLADDING Association of Unit 24-GAUGE PRE-FINISHED METAL WRB Owners of Touchstone FLASHING (TYP)WITH UPTURNED SEALANT(SEE NOTE) Townhomes END DAMS AND HEMMED DRIP EDGE I. I PRIMED CEDAR ISSUE REMOVE 2" 9" BUTYL BASED SAM FURRING 06.05.2018 AND t0 0SEALANT BEDDING 0 REPLACE • Construction Issue Set INTERIOR I , ', , ', •, ', - REVISIONS TRIM 1/2" MIN c \ ff REV. DATE • SCHEDULED TRIM- SIZE PER 6" 2" MIN. I SPECIFICATIONS- PRIME PRIOR TO MIN. / ` / j t - '4� '*/// SEALANT INSTALLATION (TYP.) ,_ r INSTALLED SWING • /// =RIM DOOR ASSEMBLY PROJECT NAME III FILLET BEAD OF COMPATIBLE SEALANT � __ � PRIMED CEDAR FURRING MINIMALLY EXPANDING Touchstone Townhomes / FOAM SEALANT 6" Targeted Building MINIMALLY EXPANDING FOAM SEALANT Enclosure Rehabilitation INSTALLED SWING DOOR ASSEMBLY REMOVE AND REPLACE PROJECT NUMBER INTERIOR TRIM (R) 17-091 SHEET NAME WALL OPENING DETAILS 4.21 TYPICAL SWING DOOR HEAD 4.22 TYPICAL SWING DOOR JAMB SHEET NUMBER 3" = 1'0" AT FIBER CEMENT CLADDING - INSTALL CONDITION 3" = 1'0" AT FIBER CEMENT CLADDING- INSTALL CONDITION 4.21 MA 4.00 Wall Opening Details-Touchstone Townhomes.dwg MA 4.00 Wall Opening Details-Touchstone Townhomes.dwg 4.22 EXAMPLE OF EXISTING OBSERVED CONDITION. NOTES: EXAMPLE OF EXISTING OBSERVED CONDITION. FORENSIC PHOTO DOES NOT REPRESENT COMPLETE 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED WALL ASSEMBLIES. PHOTO DOES NOT REPRESENT COMPLETE B U I t G I B G C U B S U t t A B 1 S SCOPE OR VARIATIONS OF CONDITIONS 2. CONTRACTOR TO ENSURE NEW TRIM AND FLASHING COMPONENTS DO NOT INTERFERE WITH SWING DOOR SCOPE OR VARIATIONS OF CONDITIONS 1582nd Drive,Suite 10 OPERATION OR GARAGE DOOR OPERATION. Gladstone,OR 97027 rr , 3, TRIM TO TUCK UNDER THRU WALL FLASHING WHERE APPLICABLE. TEL 503.7724039 2 1114 FAX 503.772.4039 4. VERIFY THAT ALL CONCRETE WALK SURFACES ARE SLOPED TO DRAIN MINIMUM 2%AWAY FROM BUILDING. NOTIFY www.forensicbuilding.com �" info@forensicbuilding.com / ,`;•. CONSULTANT IF SLOPE IS REVERSED OR INADEQUATE. �� COPYRIGHT©2017 FORENSIC 5. AT DYNAMIC SEALANT JOINTS, MAINTAIN JOINT DEPTH AT ONE HALF JOINT WIDTH. .ti BUILDING©2017 FORENSIC 6. ENSURE INSTALLED COMPONENTS ARE NOT VISIBLE BELOW SIDING AND/OR TRIM SHEET METAL FLASHING IS TO FULLY All Rights Reserved 001101 Nit OR CCB#155496�' COVER SAM FROM ALL UV EXPOSURE. It,n� " � WA FORENW C94308 7. INSTALL FILLET BEAD OF SEALANT IF ABUTTING COMPONENTS ARE TOUCHING OR ARE LESS THAN 1/4"APART. IF GAP UT#8334529-5501 IS 1/4"TO LESS THAN 1/2" INSTALL LOW EXPANDING FOAM. IF GAP IS 1/2"OR LARGER INSTALL BACKER ROD AND ks SEALANT 8. DO NOT INSTALL FASTENERS THROUGH HORIZONTAL SURFACE OF SILL PAN. SOLDERED END [--- I` EXISTING SHEATHING DAM BEYOND 7 Vll ____Ar_ ___ 4 SCHEDULED WRB, LAP OVER SAM FLASHING AND METAL HEAD FLASHING BELOW 1/2" MIN r INSTALLED SWING PRESSURE TREATED FURRING STRIP WITH DOOR ASSEMBLY `t • INSECT SCREEN AT HORIZONTAL L TERMINATIONS,TYP. PRINT ALL DETAILS IN V.I.F. COLOR AT 11x17 SWING DOOR THRESHOLD TWO BEADS TO FIBER CEMENT CLIENT COMPLETE AIR SEAL DECAY-RESISTANT SHIMS TO • 1/2" PLANK LAP BELOW THRESHOLD PROVIDE LEVEL SUPPORT AT •SILL CLADDING 4" Association of Unit SAM PAN WITH 6" END DAMS OVER 5% MIN SLOPE Owners of Touchstone INTERIOR FILLET CONTINUOUS SHIM Townhomes BEAD OF SEALANT — • 1/2" CONTINUOUS SHIM AS REQUIRED TO 1/2" ISSUE ,1 NEGATE ANY REVERSE SLOPING OR G 06.05.2018 4" PONDING AT DOOR SILL INTERIOR MIN. k_. 1/2"DYNAMIC SEALANT JOINT WITH WEEPS Construction Issue Set FINISH Om CONTINUOUS BEAD OF SEALANT FOR AIR-SEAL 1/2" MIN PRESSURE TREATED FURRING INSTALLED REVISIONS \ \ „ IS Pi* • Ama IN PLANE WITH EXTERIOR SHEATHING 24 GA. PRE-FINISHED METAL FLASHING (TYP.) REV. j DATE I ''r fT \ I r ANdifr— 1/2" SURFACE AROUND THE ROUGH OPENING WITH END DAMS AND HEMMED DRIP EDGE 24 GAUGE FULLY SOLDERED STAINLESS SET ON CONTINUOUS 3/8" BEAD OF SEALANT a STEEL SILL PAN, PROVIDE 4" ENDS DAMS 2" �� 1/2" AND 1/2" HEMMED DRIP LEG MIN. -41/2 SAM, LAP ONTO GARAGE DOOR TRIM a MIN1. ` 1/2" MIN 2" HOLD BACK SAM EDGE FROM SEALANT a l•• EXISTING - CONCRETE MIN. SCHEDULED TRIM SIZE PER SPECIFICATIONS PRIME PRIOR TO EXISTING BUILDING STEP \ • PROJECT NAME SLAB ON pRADE 6 <- SEALANT INSTALLATION (TYP.) G 1/2" Touchstone Townhomes � Targeted Building C J Q _ Enclosure Rehabilitation 24-GAUGE PRE-FINISHED METAL PROJECT NUMBER EXISTING CNCRETE THRU-WALL FLASHING WITH END DAMS PA�PIO SLA ON QRADE AND HEMMED DRIP EDGE SET ON (R) 17-091 ACONTINUOUS 3/8"BEAD OF SEALANT SHEET NAME GARAGE DOOR TRIM TO REMAIN IN PLACE WALL OPENING DETAILS 4.23 TYPICAL SWING DOOR SILL 4.24 TYPICAL GARAGE DOOR HEAD SHEET NUMBER 3" = 1'0" AT CONCRETE STEP - INSTALL CONDITION 3" = 1'0" AT FIBER CEMENT CLADDING - INSTALL CONDITION 4.23 MA 4.00 Wall Opening Details-Touchstone Townhomes.dwg MA 4.00 Wall Opening Details-Touchstone Townhomes.dwg B^4 NOTES: EXAMPLE OF EXISTING OBSERVED CONDITION. FORENSIC 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED WALL ASSEMBLIES. PHOTO DOES NOT REPRESENT COMPLETE 2. CONTRACTOR TO ENSURE NEW TRIM AND FLASHING COMPONENTS DO NOT INTERFERE WITH GARAGE DOOR OPERATION. SCOPE OR VARIATIONS OF CONDITIONS BUo r s AN 15 62nd Drive,Suite 10 3. TRIM TO TUCK UNDER THRU-WALL FLASHING WHERE APPLICABLE Gladstone,OR 97027 4. CAREFULLY REMOVE EXISTING TRIM, SIDING, AND ASSOCIATED FLASHING TO PERFORM WORK AT STONE VENEER TRANSITIONS. DO P-,---`°" ,: TEL 503.772.1114 FAX 503.772.4039 NOT REMOVE ANY STONE VENEER AND MAKE SURE TO LEAVE AT LEAST 2"OF WRB TO TIE INTO AT TRANSITIONS. www forensicbuilding com 5. AT DYNAMIC SEALANT JOINTS, MAINTAIN JOINT DEPTH AT ONE HALF JOINT WIDTH. i., nfo@forensicbuilding.com 6. ENSURE INSTALLED CONCEALED COMPONENTS ARE NOT VISIBLE BELOW CLADDING AND/OR TRIMSHEET METAL FLASHING IS TO FULLY ,- _ ., COPYRIGHT©2017 FORENSIC COVER SAM FROM ALL UV EXPOSURE. k!" - BUILDING CONSULTANTS r All Rights Reserved 7. INSTALL FILLET BEAD OF SEALANT IF ABUTTING COMPONENTS ARE TOUCHING OR ARE LESS THAN 1/4' APART. IF GAP IS 1/4"TO LESS ' OR CCB#155496 THAN 1/2" INSTALL LOW EXPANDING FOAM. IF GAP IS 1/2"OR LARGER INSTALL BACKER ROD AND SEALANT. , WA FORENW C94308 8. METAL THRU WALL FLASHING IS TO BE COMPLETE WITH UPTURNED ENDS AT TERMINATIONS AND CONTINUOUS AROUND CORNERS. UT#8334529-5501 SCHEDULED TRIM - SIZE PER SPECIFICAIONS- PRIME PRIOR TO SEALANT INSTALLATION SCHEDULED TRIM -SIZE PER SPECIFICAIONS- PRIME PRIOR TO PRESSURE TREATED FURRING STRIP SEALANT INSTALLATION WITH INSECT SCREEN AT HORIZ. PRINT ALL DETAILS IN SAM, LAP ONTO GARAGE SAM, LAP ONTO GARAGE TERMINATIONS (TYP.) COLOR AT 11x17 DOOR TRIM - HOLD BACK SEALANT FILLET BEAD DOOR TRIM- HOLD BACK CLIENT SEALANT 1/2 DYNAMIC SEALANT JOINT FROM EDGE SAM EDGE FROM PRESSURE TREATED FURRING STRIP SAM Association of Unit SEALANT WITH INSECT SCREEN AT HORIZ. �� CASING BEAD,AS OCCURS Owners of Touchstone TERMINATIONS (TYP.) Townhomes FILLET BEAD FILLET BEAD EXISTING STONE VENEER TO REMAIN OF SEALANT—\\ FIBER CEMENT PLANK LAP CLADDING OF SEALANT ° I ° IssuE • . / - ° __ 06.05.2018 9 � - Construction Issue Set I , , REVISIONS / / REV. DATE 2" 2" 2" MIN. MIN. MIN. \ \ <>- <--> , )1 / \ IL / PROJECT NAME WRB EXISTING LAYERS OF WRB TO Touchstone Townhomes REMAIN, CUT BACK FROM JAMB Targeted Building GARAGE DOOR TRIM TO EXISTING SHEATHING GARAGE DOOR TRIM TO TO ALLOW SAM TO ADHERE TO Enclosure Rehabilitation REMAIN IN PLACE REMAIN IN PLACE SHEATHING PROJECT NUMBER EXISTING SHEATHING (R) 17-091 SHEET NAME WALL OPENING DETAILS 4.25 TYPICAL GARAGE DOOR JAMB 4.26 TYPICAL GARAGE DOOR JAMB SHEET NUMBER 3" = 1'0" AT FIBER CEMENT TRIM AND CLADDING - INSTALL CONDITION 3" = 1'0" AT FIBER CEMENT TRIM AND STONE VENEER- INSTALL CONDITION 4.25 MA 4.00 Wall Opening Details-Touchstone Townhomes.dwg MA 4.00 Wall Opening Details-Touchstone Townhomes.dwg 4.26 NOTE: NOTE: FORENSIC 1. SEAL ALL FASTENERS FOR APRON FLASHING 1. ENSURE UNDERLAYMENT TURNS UP WALL MIN 8". EXAMPLE OF EXISTING OBSERVED CONDITION. ,,,,o,Y G f(Ia ,„N,s 2. ISOMETRIC DETAILS ARE TO CONVEY INTENT ONLY. NOT ALL CONDITIONS ARE SHOWN 2. NOTIFY CONSULTANT IMMEDIATELY IF EXISTING PHOTO DOES NOT REPRESENT COMPLETE 1582nd Drive,Suite 10 UNDERLAYMENT IS NOT PRESENT OR INADEQUATE. SCOPE OR VARIATIONS OF CONDITIONS Gladstone,OR 97027 TEL 503.772.1114 3. DEMO EXISTING ROOF FLASHING AND SHINGLES AS FAx 503.772.1134 METAL FLASHING 3 CONTINUOUS BEADS OF NECESSARY TO ACCESS AND PERFORM REQUIRED ` www.torensicbuilding.00m EXTEND TO A MIN. OF 3/8" DIAMETER SEALANT ROOF-TO-WALL TRANSITION FLASHING. INSTALL NEW, nto@torensicbuilding.com 4"ABOVE ROOFING SHEATHING, UNDERLAYMENT, SHINGLES,WRB, . . `:,-,,i: '-___..----- METAL COPYRIGHT CONS2017 FORENSIC METAL FLASHING +� BUILDING CONSULTANTS SURFACE MATERIAL CLADDING,AND OTHER COMPONENTS TO COMPLETE +' .. All Rights Reserved REQUIRED WORK AND IN ACCORDANCE WITH THE SCOPE OR CCB#155496 OF REPAIR AND AS SHOWN IN THE CONSTRUCTION WA FORENW C94308 4''y/� DRAWINGS. UT#8334529-5501 4"MIN 3,0 U ; , j T IOPEN DIVERTER ► ,0'Q EDGE TO A 110 DEGREE ANGLE MECHANICALLY FASTENED AND 004 • SEALED WATERTIGHT OR FULLY PLYWOOD SHEATHING SOLDERED1%0 1 TYPICAL EDGE DIVERTER 2 TYPICAL FLASHING LAP JOINT P.T. FURRING STRIPS WITH INSECT PRINT ALL DETAILS IN NOTE: SCREENS AT TERMINATIONS COLOR AT 11x17 SLIP FLASHING TOGETHER FOR A MORE FINISHED WRB, LAP OVER UNDERLAYMENT CLIENT ROOFING UNDERLAYMENT APPEARANCE VERSUS STACKING FLASHING sftiolr AND BASE OF WALL FLASHING BELOW Association of Unit 1°) ' OVERLAP EDGE FLASHING Owners of Touchstone FIBER CEMENT CLADDING Townhomes INSTALL A STRIP OF ROOFING ISSUE UNDERLAYMENT AT EAVE PRIOR TO INSTALLING FLASHING 06.05.2018 CONTINUOUS BEAD OF SEALANT FOR AIR-SEAL Construction Issue Set OQZIiiiijilt REVISIONS 5N" REV. DATE ,P°. ts I I I II II IhilftW.11141111"- 1- 1M41111....'- 11114 VERIFY EXISTING ROOFING �p�`� Oil� UNDERLAYMENT EXTENDS UP WALL 8"MIN W4*40‘‘ \ 1" FROM HIGHEST L METAL DRIP POINT OF ROOFING EDGE FLASHING 24 GA. PRE-FINISHED METAL PROJECT NAME �,4Wilb APRON FLASHING EXTEND FLASHING OVER ` 78 == ` ASPHALT SHINGLES TO MATCH Touchstone Townhomes UNDERLAYMENT ALONG � EXISTING Targeted Building �""'!; RAKES AND SEAL OVERLAP j i Ift‘ 1-a____.�� Enclosure Rehabilitation GUTTER WHERE POSSIBLE _ PROJECT NUMBER 4Mirlik * (R) 17-091 TRIM AND BEND TO FORM EXISTING UNDERLAYMENT CLOSURE AT CORNER PLYWOOD SHEATHING SHEET NAME 3 DRIP-EDGE MTL. FLASHING CORROSION RESISTANT FASTENER WITH ROOF EAVES&RAKES GASKET-PRE-DRILL AND FILL WITH WALL DETAILS COMPATIBLE SEALANT 5.00 TYPICAL ROOF FLASHING 5.01 ROOF-TO-WALL APRON FLASHING SHEET NUMBER 1 1/2" = 1-0" ISOMETRIC 3" = 1'-0" AT FIBER CEMENT CLADDING -WITH UNDERLAYMENT AT WALL 5.00 MA 5.00 Roof Details-Touchstone Townhomes.dwg MA 5.00 Roof Details-Touchstone Townhomes.dwg 5.01 NOTE: FORENSIC 1. ENSURE UNDERLAYMENT TURNS UP WALL MIN 8". ELI t o 1 Y 8 COIISMAMIS 2. NOTIFY CONSULTANT IMMEDIATELY IF EXISTING UNDERLAYMENT IS NOT PRESENT OR INADEQUATE. 15 82nd Drive,Suite 10 3. DEMO EXISTING ROOF FLASHING AND SHINGLES AS NECESSARY TO ACCESS AND PERFORM REQUIRED Gladstone,OR 97027 : ROOF-TO-WALL TRANSITION FLASHING. INSTALL NEW, SHEATHING, UNDERLAYMENT, SHINGLES,WRB, TEL503.772.1114 FAX:503.772.4039 CLADDING,AND OTHER COMPONENTS TO COMPLETE REQUIRED WORK AND IN ACCORDANCE WITH THE www.forensicbuilding.corn . SCOPE OF REPAIR AND AS SHOWN IN THE CONSTRUCTION DRAWINGS. info@forensicbuildingcorn COPYRIGHT©2017 FORENSIC BUILDING CONSULTANTS All Rights Reserved OR CCB#155496 WA FORENW C94308 UT#8334529-5501 rOli 1111 EXISTING SHEATHING METAL APRON FLASHING ' WITH HEMMED EDGE- „1111,, P.T. FURRING STRIPS WITH INSECT LAT SEP FLASHING / OVER 2" MIN. PRINT ALL DETAILS IN SCREENS AT TERMINATIONS COLOR AT 11x17 Iw I WRB, LAP OVER UNDERLAYMENT AND BASE OF WALL FLASHING Association of Unit BELOW WETAOwners of Touchstone Townhomes FIBER CEMENT CLADDING LNEXSTEP FLASHING FLASHING LAP WRB OTVER FLASHING 2" CLIENT ISSUE MIN.MITH-CONCEAL FASTENERS \ \ CONTINUOUS BEAD OF SEALANT FOR UNIT 06.05.2018 • AIR-SEAL Construction Issue Set — 1 REV. DATE REVISIONS 1101 VERIFY EXISTING ROOFING / 4 t UNDERLAYMENT EXTENDS UP WALL 8" MIN / 3"MIN 2"TYP 000%.,404 24-GAUGE PRE-FINISHED e j 1 lI METAL STEP FLASHINGpi 1"MIN 1Ilit% 6A1•004. V , A .,iii 1 NI '4" ,,_ I MIN: — 1" MIN. FROM HIGHEST PROJECT NAME POINT OF ROOFING 10*.• L.....----'''' S�0' Touchstone Townhomes _-- / / / Targeted Building Enclosure Rehabilitation 4%10 4° AMATCH SPHALT SHINGLESEXISTING TO PROJECT NUMBER \ (R) 17-091 EXISTING UNDERLAYMENT PLYWOOD SHEATHING SHEET NAME WALL DETAILS 5.02 ROOF-TO-WALL STEP FLASHING 5.03 APRON AND STEP FLASHING SHEET NUMBER 3" = 1'-0" AT FIBER CEMENT CLADDING -WITH UNDERLAYMENT AT WALL 1 1/2" = 1'-0" TRANSITION ISOMETRIC 5.02 MA 5.00 Roof Details-Touchstone Townhomes.dwg MA 5.00 Roof Details-Touchstone Townhomes.dwg 5.03 NOTE: FORENSIC 1. FOLLOW MANUFACTURER'S INSTRUCTION FOR PROPER VENT ASSEMBLY INSTALLATION. I `°a`°"""' 2. DEMO EXISTING ROOF SHINGLES AS NECESSARY TO ACCESS AND PERFORM N ASPHALT SHINGLE ROOFING 1582nd Drive,Suite 10 Gladstone,OR 97027 REQUIRED WORK. INSTALL NEW, SHEATHING, UNDERLAYMENT, SHINGLES,AND \ TEL 503.772.1114 OTHER COMPONENTS TO COMPLETE REQUIRED WORK AND IN ACCORDANCE WITH ROOFING UNDERLAYMENT FAX 503.772.4039 THE SCOPE OF REPAIR AND AS SHOWN IN THE CONSTRUCTION DRAWINGS. www.forensicbuilding.com info@forensicbuilding.com 3. COORDINATE ALL NEW DUCTWORK WITH NRCA STANDARDS. COPYRIGHT©2017 FORENSIC 4. ALL EXHAUST DUCTWORK CONNECTIONS TO BE SEALED AIR TIGHT. . CONT. BEAD OF SEALANT BUILDING CONSULTANTS 5. TREAT ALL MICROBIAL GROWTH USING INDUSTRY RECOGNIZED STANDARD MEANS ANDAT HEAD AND EACH SIDE - PRE-FINISHED GALVANIZED, All Rights Reserved METHODS FOR MICROBIAL GROWTH REMEDIATION.THIS INCLUDES CLEANING AND STEMMED STATIC EXHAUST VENT OR CCB#155496 PREPARATION USING AN ABRASIVE METHODOLOGY AND TREATING WITH A SUITABLE -.,:x\. ASSEMBLY,LAP AND SEAL WITH WA 833 5 9ENW 550105 WOOD PRESERVATIVE CONTAINING SUITABLE FUNGICIDES. SHINGLES 40106_ . INSTALL CORROSION RESISTANT ' �` FASTENER WITH NEOPRENE WASHER AT LOCATIONS SPECIFIED `�\ \\����`� BY MANUFACTURER-SEAL HEAD, CONT.BEAD OF SEALANT 4,10, . , nP SHEATHING CUT OUT FOR VENT,ADJUST \� ROOFING UNDERLAYMENT SIZE PER MANUFACTURER REQUIREMENTS ��`• ICE AND WATER PER SHINGLE MFR. INSTRUCTIONS EXISTING ROOF \O PRCO OR AT 1INT ALL 1x17 ILS IN FRAMING BEYOND \\\ PLYWOOD SHEATHING CLIENT REMOVE AND EXTEND/REPLACE ASPHALT SHINGLE ROOFING Association of Unit k / EXISTING SHEET METAL EXHAUST Owners of Touchstone DUCT,INTEGRATE WITH NEW Townhomes VENT ASSEMBLY \ ISSUE 06.05.2018 Construction Issue Set REVISIONS / REV. DATE EXAMPLE OF EXISTING OBSERVED CONDITION. ( , / PHOTO DOES NOT REPRESENT COMPLETE SCOPE OR VARIATIONS OF CONDITIONS PROJECT NAME Touchstone Townhomes Targeted Building ■ ■ Enclosure Rehabilitation tillt 1', PROJECT NUMBER I "' - EXISTING EXHAUST VENT ASSEMBLY TO REMAIN (R) 17-091 m # , SHEET NAME t ,"", ; ROOF . A .woutfritc.. ...._. DETAILS 5.04 ROOF VENT ASSEMBLY SHEET NUMBER 2" = 1'-0" AT KITCHEN / BATH EXHAUST DUCT 5.04 MA 5.00 Roof Details-Touchstone Townhomes.dwg NOTE: FORENSIC 1. FOLLOW MANUFACTURER'S INSTRUCTION FOR PROPER VENT ASSEMBLY INSTALLATION. EXAMPLE OF EXISTING OBSERVED CONDITION. e,I L,I N L r o a 5 0 I r a w, 2. DEMO EXISTING ROOF SHINGLES AS NECESSARY TO ACCESS AND PERFORM PHOTO DOES NOT REPRESENT COMPLETE 15 82nd Drive,Suite 10 REQUIRED WORK. INSTALL NEW, SHEATHING, UNDERLAYMENT, SHINGLES,AND SCOPE OR VARIATIONS OF CONDITIONS Gladstone,OR 97027 TEL:503.772.1114 OTHER COMPONENTS TO COMPLETE REQUIRED WORK AND IN ACCORDANCE WITH FAX:503.772.4039 THE SCOPE OF REPAIR AND AS SHOWN IN THE CONSTRUCTION DRAWINGS. www.forensicbuilding.com info@forensicbuilding.corn 3. TREAT ALL MICROBIAL GROWTH USING INDUSTRY RECOGNIZED STANDARD MEANS AND METHODS FOR MICROBIAL GROWTH REMEDIATION.THIS INCLUDES CLEANING ANDCOPYRIGHT 02017 FORENSIC BUILDING CONSULTANTS PREPARATION USING AN ABRASIVE METHODOLOGY AND TREATING WITH A SUITABLE1 All Rights Reserved WOOD PRESERVATIVE CONTAINING SUITABLE FUNGICIDES. OR CCB#155496 WA FORENW C94308 UT#8334529-5501 CONTINUOUS BEAD OF SEALANT PRINT ALL DETAILS IN COLOR AT 11x17 AT HEAD AND EACH SIDE CLIENT 1 N\ Association of Unit Owners of Touchstone """""--""""" Townhomes I � � INSTALL FLANGED PRE-MANUFACTURED MOTORIZED VENTILATION UNIT WITH MIN. ISSUE `` CODE COMPLIANT CFM/SQ.FT. CAPACITY _ 06.05.2018 // //iiip//,� Construction Issue Set /////////////i;;.i...��„""'„" v SHEATHING CUT OUT FOR VENT INSTALL �0, // /%�����// tt A it.. PER MANUFACTURERS REQUIREMENTS REVISIONS //// ///////C',.../1r f3.% �,..:. REV. DATE CORROSION-RESISTANT � FASTENER CAPPED WITH ////� �/ EXISTING ROOFING UNDERLAYMENT TO REMAIN COMPATIBLE SEALANT '. \� /i�//'4'//,/, EXISTING ASPHALT SHINGLE ROOFING TO REMAIN, .`� INSTALL REPLACEMENT SHINGLE TO MATCH EXISTING EXISTING ROOF JOISTS TO REMAIN ``` EXISTING SHEATHING TO REMAIN,REPLACE DAMAGED PROJECT NAME -.44, SHEATHING AS NECESSARY,MATCHING EXISTING THICKNESS AND RATING. �`� Touchstone Townhomes Targeted Building `` Enclosure Rehabilitation PROJECT NUMBER (R) 17-091 SHEET NAME - NOTE: ROOF 1. FOLLOW MANUFACTURER'S INSTRUCTION FOR PROPER VENT ASSEMBLY INSTALLATION. DETAILS 2. DEMO EXISTING ROOF SHINGLES, UNDERLAYMENT,AND DAMAGED PLYWOOD SHEATHING AT AREAS . INSTALL NEW, SHEATHING, UNDERLAYMENT, SHINGLES,AND 5.05 ACTIVE ATTIC VENTILATION UNIT COMPO ENOF SVTOC OMPL TE REQUIRED WORK AND N ACCORDANCE WITH THE SCOPE OTHER SHEET NUMBER OF REPAIR AND AS SHOWN IN THE CONSTRUCTION DRAWINGS. 3" = 1'-0" PENETRATION AT PITCHED ROOF CONDITION 3. COORDINATE ALL NEW DUCTWORK WITH NRCA STANDARDS. .05 mhg 5.00 Roof Details-Touchstone Townhomes.dwg 4. ALL EXHAUST DUCTWORK CONNECTIONS TO BE SEALED AND TIGHT-LINED TO VENT ASSEMBLY. v NOTES: FORENSIC 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED WALL ASSEMBLIES. B U I t e 111 U COISUIFANIS 2. DECK DETAILING, RAILING,AND FIBER CEMENT WALL CLADDING AND TRIM ASSEMBLIES TO REQUIRE 1582nd Drive,Suite 10 WORKING CLEARANCES. Gladstone,OR 97027 TEL 503.772.1114 FAX 503.772.4039 www.forens icbu i Id ing.com 6.07 6.02 4.16 4.19 info@forensicbuild ing.corn EAD SILL COPYRIGHT 02017 FORENSIC 6.12 4.17 BUILDING CONSULTANTS JAMB •.05A All Rights Reserved )...._ OR CCB#155496 WA FORENW C94308 UT#8334529-5501 \ EXAMPLE OF EXISTING OBSERVED CONDITION. Alk 1® :z LINE OF ROOF PHOTO DOES NOT REPRESENT COMPLETE 0 6.03 OVERHANG ABOVE SCOPE OR VARIATIONS OF CONDITIONS SIM. ;; e; A,„1.,,„.-qmiqi Ak.01'I,. Y ALTERNATE THIN-SET TILE INDICATED OVER MORTAR BED '}fir ' ACRYLIC CEMENTITIOUS ,� ,,, � � �� ., REINFORCED DECK (NOT BASE SCOPE OF WORK) �' ;.,L COATING SYSTEM 6.04 6.03 PRINT ALL DETAILS IN 41, COLOR AT 11x17 i CLIENT w 6.00A ENLARGED UPPER FLOOR WATERPROOF Association of Unit - ;� Owners of Touchstone 1/4" = 1-0" DECK CONDITION AT BUILDINGS 1 REAR ELEVATION Townhomes mhg NOTE: REFERENCE DECK PLANS ARE REPRODUCED BASE ON PROVIDED ISSUE CONSTRUCTION DOCUMENTS, EXISTING SITE OBSERVATIONS AND CONDITIONS OBSERVED AT LIMITED LOCATIONS AND ARE FOR TYPICAL OR SIMILAR PROJECT 06.05.2018 DETAIL CALLOUTS. BRING DISCREPANCIES BETWEEN DESIGN DOCUMENTS AND ACTUAL PROJECT CONDITIONS TO THE IMMEDIATE ATTENTION OF THE BUILDING Construction Issue Set ENVELOPE CONSULTANT AND REQUEST A REVIEW. REVISIONS REV. DATE 4.16 EAD 6.08 6.12 ® VP _ ® \--- _ I 1 1 —1 PROJECT NAME LINE OF ROOF 16.10 EXAMPLE OF EXISTING OBSERVED CONDITION. Touchstone Townhomes OVERHANG ABOVE SIM PHOTO DOES NOT REPRESENT COMPLETE SCOPE OR VARIATIONS OF CONDITIONS Targeted Building Enclosure Rehabilitation _:______________________________ 2x6 WESTERN CEDAR DECKING PROJECT NUMBER 6.10 . �_� ,,... (R) 17-091 NOTE : EXISTING DECKING TO BE REMOVEDI0 4 ` AND REPLACED WITH CEDAR DECKING TO ''�! * x SHEET NAME MATCH EXISTING SIZE, ORIENTATION, AND / .c; ENLARGED DECK LAYOUT. INSTALL WITH 1/4"SPACING. PLANS €.;fir;,. << 1;!Al, $ \\ i 6.006 ENLARGED UPPER FLOOR FLOW-THRU � - ►�„� �111 Wr-"''� �'�` *- t SHEET NUMBER.- � 1/4" = 11-0" DECK CONDITION AT BUILDING 2 REAR ELEVATION mhg 6.008 EXTEND SHEET MEMBRANE 8"MIN. UP WALL. TOP COURSE WRB NOT SHOWNF O R E N S I C 3" eu��o��o ��Wsa<<�n,s ��� Q DECK-TO-WALL FLASHING PER DETAILS- LAP 1582nd Suite 10 LAP SILL PAN FLANGE OVER DECK- o',— OVER SADDLE AND SEAL WITH SEALANT OR Gladstone,Drive,OR 97e 1 TO WALL FLASHING AND SEAL WITH BASE COAT TEL:503.772.1114 3 BEADS SEALANT/DECK COATING ' FAX:503.772.4039 TO SHEET MEMBRANE WRB TOP COURSE NOT SHOWN v✓ww.forensicbuilding.com INSTALL WP40 SHEET MEMBRANE, nfo@forensicbuilding.com COPYRIGHT©2017 FORENSIC EXTEND TO WALL AND OVER DOOR EXTEND SHEET MEMBRANE 8" BUILDING CONSULTANTS FULLY SOLDERED BONDERIZED THRESHOLD TO ALIGN WITH All Rights Reserved METAL SILL PAN WITH MINIMUM i MIN. UP WALL. OR CCB#155496 PLACEMENT OF METAL SILL PAN 1/2" BACK DAM, SET OVER BASE WAFORENWC94308 00>."------71:: UT#8334529-5501 24-GAUGE BONDERIZED ND SEALED TO WRB SHEET ADECK-TO-WALL FLASHING PER 7-1 6" DETAILS-SEAL WITH SEALANT > / j 4" PRINT ALL DETAILS IN COLOR AT 11x17 � � INSTALL WP40 SHEET CLIENT MEMBRANE, EXTEND Association of Unit VERTICALLY UP WALL Owners of Touchstone Townhomes j ISSUE 06.05.2018 Construction Issue Set REVISIONS i REV. DATE NOTE: i 1. VERIFY THAT ALL DECK SURFACES ARE SLOPED TO DRAIN MINIMUM 2%. NOTIFY CONSULTANT IF SLOPE IS REVERSED OR INADEQUATE. 2. MECHANICALLY FASTEN BASE FLASHING AS REQUIRED BY DETAILS AND MANUFACTURER'S REQUIREMENTS. %� PROJECT NAME 3. VERIFY ADEQUATE ADHESION OFCEMENTITIOUS SHEET MEMBRANE / Touchstone Townhomes SHEATHING AND FLASHING PRIOR TO APPLICATION. Targeted Building 4. INSTALL CEMENTITIOUS DECK COATING SYSTEM IN CONFORMANCE Enclosure Rehabilitation WITH MANUFACTURER'S INSTRUCTIONS. LAP AND SEAL METAL FLASHING IN CONFORMANCE WITH PROJECT DOCUMENTS. COMPLETE ACRYLIC CEMENTITIOUS PROJECT NUMBER 5. THREE-DIMENSIONAL DRAWINGS ARE INTENDED TO ILLUSTRATE REINFORCED DECK COATING SYSTEM I (R) 17-091 SPECIFIC CONCEPTS OF COMPONENTS INSTALLATION. NOT ALL PER DESIGN DOCUMENTS, EXTEND ` ASSEMBLY COMPONENTS ARE SHOWN. OVER METAL DECK-TO-WALL SHEET NAME 6. LIGHTLY ABRADE ALL STAINLESS STEEL METAL FLASHING SURFACES FLASHING (AND METAL SILL PANS (AS OCCURS)TO RECEIVE DECK COATING. DO NOT ABRADE DECK WHERE OCCURS), AND UP VERTICAL BONDERIZED FLASHING PROVISIONS. DETAILS FLASHING LEG, TYP. INSTALL THIN-SET TILE DECK 6.01 FRAMED DECK FLASHING INSTALL CLADDING (NOT SHOWN) SHEET NUMBER 1 1/2" = 1'-0" AT WATERPROOF DECK ASSEMBLY- ISOMETRIC DETAILS 6.01 mhg NOTES: FORENSIC 1. CONTRACTOR TO VERIFY AND MAINTAIN ALL RATED WALL ASSEMBLIES AND CLEARANCE REQUIREMENTS. I5 ONSOLIANIS A SCHEDULED WRB- LAP OVER EDGE OF 2. VERIFY THAT ALL DECK SURFACES ARE SLOPED TO DRAIN MINIMUM 2%. NOTIFY CONSULTANT IF SLOPE IS 1582nd Drive,Suite 10 DECK COATING AND VERTICAL LEG OF REVERSED OR INADEQUATE. Gladstone,OR 97027 DECK-TO-WALL FLASHING BELOW 3. MECHANICALLY FASTEN BASE FLASHING AS REQUIRED BY DETAILS AND MANUFACTURERS TEL 503.772.1114 FAX 503.772.4039 REQUIREMENTS. VERIFY ADEQUATE ADHESION OF CEMENTITIOUS DECK COATING TO SHEET MEMBRANE www.forensicbuilding corn SCHEDULED PRESSURE TREATED AND FLASHING PROVISIONS PRIOR TO APPLICATION. nfo@forensicbuiiding.com FURRING STRIP WITH INSECT SCREEN FIBER CEMENT PLANK LAP CLADDING 6. INSTALL METAL BASE FLASHING AND CEMENTITIOUS DECK COATING SYSTEM IN CONFORMANCE WITH COPYRIGHT©2017 FORENSIC MANUFACTURERS INSTRUCTIONS. LAP AND SEAL METAL FLASHING IN CONFORMANCE WITH PROJECT BUILDINGRghtsOReservedNTs All DOCUMENTS AT CORNERS AND DOOR SILL PAN. OR CCB#155496 WAFORENWC94308 7. SHEET METAL FLASHING IS TO FULLY COVER SAM FROM ALL UV EXPOSURE, TYPICAL. EXTEND WP40 SHEET MEMBRANE W -41:1 VERTICALLY UP WALL MIN. 2" BEYOND 8. CONTRACTOR TO AIR SEAL CANTILEVERED FRAMING THROUGH EXTERIOR WALL ASSEMBLY. UT#8334529-5501 EXISTING _ UNDERLAYMENT, FLASHING LEG PLYWOOD MIN. ( �I1 , DECKING,AND e CONTINUOUS SEALANT, VERIFY FLOOR JOIST2„ COMPATIBILITY WITH PEDESTRIAN COATING FRAMING TO MIN. VAMTBERIZED METAL DECK- REMAIN `1 TO-WALL FLASHING 11 ACRYLIC ACRYLIC CEMENTITIOUS REINFORCED -- for . i DECK COATING SYSTEM ��� I� 2%SLOPE - 4.11"1 . 1112" TO DRAIN alli PRINT ALL DETAILS IN CLR. y��',y�,�y • / • / wag 6" COLOR AT 11x17 I I�� , 11.1 CLIENT I 1 , Association of Unit FILL 'PS WITH � 1 REMOVED EXISTING Owners of Touchstone CO P`TIBLE I PLYWOOD AND INSTALL Townhomes \ SE`LA T ALTERNATE THIN-SET TILE \ I 3/4"T&G PLYWOOD 4ssuE I DECK SHEATHING INDICATED OVER MORTAR BED (NOT BASE SCOPE OF 06.05.2018 1 i WP40 SHEET MEMBRANE, WORK) II I FULLY COVER DECK Construction Issue Set I I SHEATHING I / REVISIONS I 11 EXISTING CANTILEVERED DECK JOISTS, / PLYWOOD SOFFIT SHEATHING REV. DATE I BLOCKING, AND FRAMING TO REMAIN SCHEDULED WRB I / A._ I 1 .1.11111"1.11.11MINI=11111101111.1.1MMENNIIII -Alm 2 SCHEDULED FIBER ‘/11N" . FIBER CEMENT CEMENT TRIM PRIME <VIM 1/4"CLEAR GAP PROJECT NAME PRIOR TO SEALANT INFOR VENTILATION SOFFIT PANEL CLADDING INSTALLATION, (TYP.) (DO NOT SEAL) Touchstone Townhomes FILLET BEAD OF Targeted Building SEALANT Enclosure Rehabilitation 4"SAM PROJECT NUMBER SCHEDULED PRESSURE TREATED (R) 17-091 FURRING STRIP WITH INSECT SCREEN Ompow. ., , SCHEDULED WRB SHEET NAME DECK ,\, SCHEDULED FIBER CEMENT DETAILS PLANK LAP CLADDING 6.02 BASE OF WALL-TO-DECK TRANSITION SHEET NUMBER 3" = 1'-0" AT WOOD FRAMED WATERPROOF DECK ASSEMBLY 6.02 mhg NOTE: FORENSIC 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED WALL ASSEMBLIES. FF o t 0 I C 2. CAREFULLY REMOVE CLADDING TO BE REHABILITATED. DO NOT DAMAGE THE EXISTING UNDERLYING 15 82nd Drive,Suite 10 WRB. NOTIFY CONSULTANT IF EXISTING WRB IS NOT PRESENT. Gladstone,OR 97027 3. DECK SURFACE TO BE 2% MIN. SLOPE TO DRAIN TEL 503.772.1114 FAX 503.772.4039 4. INSTALL METAL BASE FLASHING AND CEMENTITIOUS DECK COATING SYSTEM IN CONFORMANCE WITH www.forensicbuilding.com MANUFACTURER'S INSTRUCTIONS. LAP AND SEAL METAL FLASHING IN CONFORMANCE WITH PROJECT info@forensicbuilding.com DOCUMENTS AT CORNERS AND DOOR SILL PAN. COPYRIGHT©2017 FORENSIC TANTS CONS G UL 5. SHEET METAL FLASHING IS TO FULLY COVER SAM FROM ALL UV EXPOSURE, TYPICAL. All BUILDINNGRights Reserved OR CCB#155496 WA FORENW C94308 UT#8334529-5501 ALTERNATE THIN-SET TILE INDICATED OVER MORTAR BED (NOT BASE SCOPE OF WORK) PLANE PLYWOOD AT DOWN-SLOPE EDGE ONLY FOR COMPONENT INTEGRATION AND FOR ACRYLIC CEMENTITIOUS MINIMUM DIRECTIONAL FLOW INTERRUPTION REINFORCED DECK COATING SYSTEM 24-GAUGE BONDERIZED METAL DECK EDGE 4" 2%SLOPE FLASHING, PAINT WHERE EXPOSED, TYP. TO DRAIN 11 PRINT CO OR AT 11x17 ILS IN i '� CONTINUOUS PRESSURE TREATED BLOCKING • r CLIENT / / / _/ / / / � EXTEND WP-40 OVER DECK EDGE 3 Association of Unit I E MIN. 2" LAP OVER SAM BELOW V.I.F. Owners of Touchstone 1/2" Townhomes 1" MIN. 1� REMOVED EXISTING PLYWOOD I MIN. ISSUE AND INSTALL 3/4"T&G SAM OVER FACE OF SHEATHING, EXTEND 06.05.2018 PLYWOOD DECK SHEATHING OVER SAM AND DRIP FLASHING BELOW WP40 SHEET MEMBRANE Construction Issue Set REVISIONS SCHEDULED WRB PRE-STRIPE EXISTING CANTILEVERED DECK JOISTS, REV. DATE N • 24-GAUGE PRE-FINISHED METAL DRIP BLOCKING,AND FRAMING TO REMAIN FLASHING WITH BACK HEM 2' SCHEDULED 4/4 FIBER CEMENT TRIM, PRIME • PLYWOOD SOFFIT ��/ PRIOR TO SEALANT INSTALLATION SHEATHING ` PRESSURE TREATED FURRING STRIP WITH SCHEDULED WRB INSECT SCREEN AT HORIZONTAL TERMINATIONS 5.. 24-GAUGE PRE-FINISHED METAL PROJECT NAME DRIP FLASHING WITH BACK HEM // / � � /7 ITouchstone Townhomes 1/2" d . \ Targeted Building FIBER CEMENT MIN. • Enclosure Rehabilitation SOFFIT PANEL PROJECT NUMBER CLADDING SEALANT (R) 17-091 SHEET NAME DECK DETAILS 6.03 DECK EDGE FLASHING TRANSITION SHEET NUMBER 3" = 1'-0" AT WOOD FRAMED WATERPROOF DECK ASSEMBLY 6.03 mhg NOTE: FORENSIC 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED WALL ASSEMBLIES. e„,,o,,, , w s „,; 2. CAREFULLY REMOVE CLADDING TO BE REHABILITATED. DO NOT DAMAGE THE EXISTING UNDERLYING 15 82nd Drive,Suite 10 WRB. NOTIFY CONSULTANT IF EXISTING WRB IS NOT PRESENT. Gladstone,OR 97027 3. DECK SURFACE TO BE 2% MIN. SLOPE TO DRAIN TEL:503.772.1114 FAX 503.772.4039 REMOVE, SAFELY STORE,AND 1,— 4. INSTALL METAL BASE FLASHING AND CEMENTITIOUS DECK COATING SYSTEM IN CONFORMANCE WITH www.forensicbuilding.corn REINSTALL GUARDRAIL SYSTEM MANUFACTURER'S INSTRUCTIONS. LAP AND SEAL METAL FLASHING IN CONFORMANCE WITH PROJECT info@forensicbuilding.com DOCUMENTS AT CORNERS AND DOOR SILL PAN. COPYRIGHT©2017 FORENSIC BUILDING CONSULTANTS 5. SHEET METAL FLASHING IS TO FULLY COVER SAM FROM ALL UV EXPOSURE, TYPICAL. All Rights Reserved OR CCB#155496 WA FORENW C94308 UT#8334529-5501 ALTERNATE THIN-SET TILE INDICATED OVER MORTAR BED (NOT BASE SCOPE OF WORK) PLANE PLYWOOD EDGE AT DECK COMPONENT ACRYLIC CEMENTITIOUS INTEGRATION FOR MIN. FLOW REINFORCED DECK DIRECTION INTERRUPTION COATING SYSTEM 1/4" NEOPRENE 24-GAUGE BONDERIZED METAL 2%SLOPE GASKET SECURED DECK EDGE FLASHING, PAINT 4" TO DRAIN WITH SEALANT WHERE EXPOSED, TYP. PRINT ALL DETAILS IN �� COLORCLIEANTT 11x17 f . -;':/.. .•ii. i ;; i/;i/ ;i/,, / :/:;i/ .'-:i �/.:i/'//—"Z:///- 1r . "./////-:.i 7�f : CONTINUOUS PRESSURE TREATED BLOCKING \ j / ' / / / �� / XISTING METAL ATTACHMENT BRACKET Association of Unit / TO BE REMOVED AND REINSTALLED 3" Owners of Touchstone jrr V.I.F. Townhomes 1„ 1/2" ) . SOLID INNYLON SPACER BEHIND BRACKET MIN. • ISSUE e 06.05.2018 4, NEOPRENE GASKET AT POST BASE MOUNTING BRACKET \ Construction Issue Set REVISIONS ,; STAINLESS STEEL FASTENER WITH NEOPRENE WASHER- PRE-DRILL AND SEAL REV. DATE l,yv1vy11'MAX'"'''i ''''`I t . ia \ 1" 2' 8 1/2" 24-GAUGE PRE-FINISHED METAL DRIP FLASHING WITH BACK HEM V.I.F. • ISCHEDULED 4/4 FIBER CEMENT TRIM, PROJECT NAME PRIME PRIOR TO SEALANT INSTALLATION / i / / / / / / / / / / 1/2" 0 Townhomes MI Targeted Building Enclosure Rehabilitation PROJECT NUMBER (R) 17-091 SHEET NAME DECK DETAILS 6.04 DECK EDGE FLASHING WITH GUARDRAIL ATTACHMENT SHEET NUMBER 3" = 1'-0" AT WOOD FRAMED WATERPROOF DECK ASSEMBLY 6.04 mhg FORENSIC INSTALL SHEET MEMBRANE 8VILDIWG IJSULTANIS TO DECK EDGE AND EXTEND 15 82nd Drive,Suite 10 Gladstone,OR 97027 STEP 2 8" MIN.VERTICALLY UP WALL TELtone 72.11 2 STEP 1 SURFACE,AND 2" MIN. DOWN FAX 503.772 4039 OVER SAM FLASHING BELOW www.forensicbuilding.com $" info@forensicbuilding.com % ,,,,t,,,,„ , COPYRIGHT©2017 FORENSIC BUILDING CONSULTANTS ' �,,,. All Rights Reserved OR CCB#155496 1111111111 IlLe°#°° 111„..... - 01.1•1•0401011'' iiiiioloir, _ ,,,4, WA FORENW 094308 EXAMPLE OF EXISTING OBSERVED CONDITION. UT#8334529-5501 PHOTO DOES NOT REPRESENT COMPLETE f. __:„_,,,,..:_i_____. _,„.„-,t _ „„. , .. ___ ,..,.,.„,... , , ,„..., ��°e� SCOPE OR VARIATIONS OF CONDITIONS 00/i° iio.ir INSTALL SAM ` , „ . .. , „ , ... , .., _ ,, ,„ ir INSTALL SOFFIT ` PRINT ALL DETAILS IN COMPONENTS, ✓ COLOR AT 11x17 REFER TO0 CLIENT DETAIL 6.03 1/2" Association of Unit 24-GAUGE PRE-FINISHED METAL DRIP NOTE: INSTALL REPLACEMENT CDX Owners of Touchstone FLASHING WITH HEMMED EDGE PLYWOOD SHEATHING, PRESSURE Townhomes TREATED FRAMING,AND Z-MAX SAM, LAP OVER DRIP FLASHING COMPONENTS CONNECTION HARDWARE AS BELOW, INSTALL AT INSIDE CORNER PRIOR TO ISSUE SOFFIT FLASHING NECESSARY TO CORRECT DAMAGED COMPONENT ASSEMBLIES. 06.05.2018 INSTALL 5/8"MIN. (3/4" RECOMMENDED) T&G CDX PLYWOOD SHEATHING Construction Issue Set REVISIONS STEP 3 REV. DATE ,1111 NOTE: 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED WALL ASSEMBLIES. 2. VERIFY THAT ALL DECK SURFACES ARE SLOPED TO DRAIN MINIMUM 2%.NOTIFY CONSULTANT IF SLOPE IS REVERSED OR INADEQUATE. 3. CAREFULLY REMOVE SCHEDULED TRIM AND CLADDING AT ELEVATION(S)TO BE REHABILITATED. DO NOT DAMAGE THE EXISTING UNDERLYING WRB.NOTIFY CONSULTANT IF EXISTING WRB IS NOT PRESENT. 4. PREP NEW AND EXISTING TRIM AND CLADDING AS REQUIRED TO RECEIVE FINISH. PROJECT NAME 5. MECHANICALLY FASTEN BASE FLASHING AS REQUIRED BY DETAILS AND MANUFACTURER'S REQUIREMENTS. s�°P� 6. VERIFY ADEQUATE ADHESION OF PEDESTRIAN DECK COATING SHEET MEMBRANE TO SHEATHING PRIOR TO Touchstone Townhomes APPLICATION. Targeted Building 7. INSTALL UNDERLAYMENT ANDPEDESTRIAN DECK COATING SYSTEM IN CONFORMANCE WITH MANUFACTURER'S Enclosure Rehabilitation INSTRUCTIONS. LAP AND SEAL METAL FLASHING IN CONFORMANCE WITH PROJECT DOCUMENTS. 8. DO NOT ABRADE BONDERIZED FLASHING PROVISIONS. PROJECT NUMBER 9. DECK RAIL POSTS HAVE BEEN OMITTED FOR CLARITY. /I 10. THREE-DIMENSIONAL DRAWINGS ARE INTENDED TO ILLUSTRATE SPECIFIC CONCEPTS OF COMPONENTS _ (R) 17 091 INSTALLATION.NOT ALL ASSEMBLY COMPONENTS ARE SHOWN. INSTALL CONTINUOUS11111 14 1,,,,r SHEET NAME PRESSURE TREATED IINSTALL OFFSET BELLYBAND DECK BLOCKING L,` I ql1" TRIM, REFER TO DETAIL 3.23 DETAILS INSTALL SCHEDULED FURRING 6.05A WATERPROOF DECK-TO-WALL SADDLE FLASHING SHEET NUMBER INSTALL SCHEDULED FIBER CEMENT 1" = 1'-0" TRANSITION CONDITION 1 AT PERPENDICULAR CONDITION - ISO. SEQ. 1 OF 2 TRIM CLADDING REFER TO DECK EDGE 6.05A DETAIL 6.03 AND 6.04 �' FORENSIC 4n AUI L0I YC ON50tf AN 1's 15 82nd Drive,Suite 10 Gladstone,OR 97027 TEL:503.772.1114 *01 FAX 503.772.4039 ��,2 www.forensicbuilding.com FAX:5377 .43 info@forensicbuilding.com 4„ COPYRIGHT©2017 FORENSIC I BUILDING CONSULTANTS INSTALL 24-GAUGE BONDERIZED All Rights Reserved STEP 5 DECK-TO-WALL FLASHING. EMBED CCB#155496 WAFORENW 094308 IN SEALANT PER DETAILS AND LAP UT#8334529-5501 I 6" ' OVER END PIECE. `, FULLY SOLDERED 24-GAUGE BONDERIZED DIVERTER FLASHING 010 INTEGRATE UNDER BASE OF WALL FLASHING AND SEAL A"24-GAUGE BONDERIZED FULLY "SOLDERED SADDLE FLASHINGWET SET IN SEALANT BED 4:74.0g. PRINT ALL DETAILS IN 41 COLOR AT 11x17 hil' d r11"1 CLIENT Association of Unit Owners of Touchstone Townhonies COMPLETED PEDESTRIAN DECK COATING AT STEP 4 ALL SURFACES PER DRAWINGS ISSUE 06.05.2018 SEAL ABUTTING FLASHING LAP WRB OVER DECK-TO-WALL AND SADDLE Construction Issue Set WITH 3- BEADS OF SEALANT FLASHING COMPONENTS AND SEAL REVISIONS STEP 6 4.4 I CONTINUOUS SEALANT REV. DATE INSTALL THRU-WALL HEAD FLASHING ANTS T BELLYBAND TRIM,ADJUST END DAM iiii*.% Nli1A‘LI* s�°Q�c 1 „,A11X' HEIGHT TO ALIGN WITH DECK-EDGE , FLASHING, REFER TO DETAIL 3.23 \ 410000t optio, 41141lik ��°Q� � /• PROJECT NAME 16. Touchstone Townhomes Targeted Building ` EnclosureRehabilitation 41 i INSTALL 24-GAUGE PRE-FINISHED rit 'h FLASHING WITH HEMMED DRIP 114 PROJECTNUMBERINSTALL 24-GAUGE BONDERIZED (R) 17 091 NI METAL DECK EDGE FLASHING WITHi HEMMED DRIP SET IN SEALANT BEAD SHEET NAME DECK DETAILS 6.05B WATERPROOF DECK-TO-WALL SADDLE FLASHING SHEET NUMBER INSTALL THIN-SET TILE DECK CLADDING 1” = 1'-0" TRANSITION CONDITION 1 AT PERPENDICULAR CONDITION - ISO. SEQ. 2 OF 2 OVER MORTAR BED (NOT SHOWN) 6,058 INSTALL SHEET MEMBRANE FC)RE NSI C 811 LUIY6 4UN SU lI ANiS TO DECK EDGE AND EXTEND 1582nd Drive,Suite 10 8" MIN. VERTICALLY UP WALL Gladstone,OR97027 STEP 1 STEP 2 TEL 503.772.1114 SURFACE,AND 2" MIN. DOWN FAX 503.772.4039 8" OVER SAM FLASHING BELOW www.forensicbuilding corn info@forensicbuilding.com COPYRIGHT©2017 FORENSIC BUILDING CONSULTANTS All Rights Reserved OR CCB#155496 WA FORENW 094308 EXAMPLE OF EXISTING OBSERVED CONDITION. uT#a33a5z9-5so1 PHOTO DOES NOT REPRESENT COMPLETE 7,\I \ ill SCOPE OR VARIATIONS OF CONDITIONS ll OIY— INSTALL SAM PRINT ALL DETAILS IN INSTALL SOFFIT COMPONENTS, �-- COLOR AT 1x17 REFER TO ,�.�. DETAIL 6.03 1/2" CLIENT Association of Unit 24-GAUGE PRE-FINISHED METAL DRIP NOTE: INSTALL REPLACEMENT CDX Owners of Touchstone FLASHING WITH HEMMED EDGE PLYWOOD SHEATHING, PRESSURE Townhomes TREATED FRAMING,AND Z-MAX SAM, LAP OVER DRIP FLASHING COMPONENTS CONNECTION HARDWARE AS ISSUE BELOW, INSTALL AT INSIDE CORNER PRIOR TO NECESSARY TO CORRECT DAMAGED SOFFIT FLASHING COMPONENT ASSEMBLIES. 06.05.2018 INSTALL 5/8" MIN. (3/4" RECOMMENDED) T&G CDX PLYVVOOD SHEATHING Construction Issue Set REVISIONS STEP 3 REV. DATE NOTE: 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED WALL ASSEMBLIES. 2. VERIFY THAT ALL DECK SURFACES ARE SLOPED TO DRAIN MINIMUM 2%. NOTIFY CONSULTANT IF SLOPE IS REVERSED OR INADEQUATE. 3. CAREFULLY REMOVE SCHEDULED TRIM AND CLADDING AT ELEVATION(S)TO BE REHABILITATED.DO NOT DAMAGE THE EXISTING UNDERLYING WRB.NOTIFY CONSULTANT IF EXISTING WRB IS NOT PRESENT. 4. PREP NEW AND EXISTING TRIM AND CLADDING AS REQUIRED TO RECEIVE FINISH. PROJECT NAME 5. MECHANICALLY FASTEN BASE FLASHING AS REQUIRED BY DETAILS AND MANUFACTURER'S REQUIREMENTS. s�°P 6. VERIFY ADEQUATE ADHESION OF PEDESTRIAN DECK COATING SHEET MEMBRANE TO SHEATHING PRIOR TO (� Touchstone Townhomes APPLICATION. 1, Targeted Building 7. INSTALL UNDERLAYMENT ANDPEDESTRIAN DECK COATING SYSTEM IN CONFORMANCE WITH MANUFACTURER'SEnclosure Rehabilitation INSTRUCTIONS.LAP AND SEAL METAL FLASHING IN CONFORMANCE WITH PROJECT DOCUMENTS. 8. DO NOT ABRADE BONDERIZED FLASHING PROVISIONS. pilif000t, PROJECT NUMBER 9. DECK RAIL POSTS HAVE BEEN OMITTED FOR CLARITY. (R) 17-091 10. THREE-DIMENSIONAL DRAWINGS ARE INTENDED TO ILLUSTRATE SPECIFIC CONCEPTS OF COMPONENTS II��4 INSTALLATION. NOT ALL ASSEMBLY COMPONENTS ARE SHOWN. 41 INSTALL ALIGNED BELLYBAND TRIM, SHEET NAME INSTALL CONTINUOUS I REFER TO DETAIL 3.23 FOR SIMILAR PRESSURE TREATED II DECK BLOCKING DETAILS INSTALL SCHEDULED FURRING 6.06A WATERPROOF DECK-TO-WALL SADDLE FLASHING SHEET NUMBER INSTALL SCHEDULED FIBER CEMENT 1" = 1'-0" TRANSITION CONDITION 1 AT PERPENDICULAR CONDITION - ISO. SEQ. 1 OF 2 TRIM CLADDING REFER TO DECK EDGE 6.06A DETAIL 6.03 AND 6.04 V V 6" FORENSIC 4 SVIIDINC tONSUIIANIS 15 82nd Drive,Suite 10 \ lb Gladstone,OR 97027 TEL:503.772.1114 FAX: .4039 nsicbuilding. fn o@forensicbuilding.com COPYRIGHT©2017 FORENSIC I BUILDING CONSULTANTS INSTALL 24-GAUGE BONDERIZED All Rights Reserved STEP 5 DECK-TO-WALL FLASHING. EMBED CCB#155496 WAFORENWC94308 IN SEALANT PER DETAILS AND LAP UT#8334529-5501 I %01 OVER END PIECE. FULLY SOLDERED 24-GAUGE At BONDERIZED DIVERTER FLASHING . 11011110 INTEGRATE UNDER BASE OF WALL FLASHING AND SEAL . 10,0A r 24-GAUGE BONDERIZED FULLY O SOLDERED SADDLE FLASHING ` WET SET IN SEALANT BED PRINT ALL DETAILS IN rri COLOR AT 11x17 CLIENT , 41 111!li Association of Unit , Owners of Touchstone Townhomes COMPLETED CEMENTITOUS DECK STEP 4 141 0 COATING AT ALL SURFACES PER ISSUE DRAWINGS 06.05.2018 111%111 1011 ti r v. SEAL ABUTTING FLASHING LAP WRB OVER DECK-TO-WALL AND SADDLE Construction Issue Set WITH 3-BEADS OF SEALANT ti 1 p p,,,,, FLASHING COMPONENTS AND SEAL REVISIONS STEP 6 INSTALL THRU-WALL HEAD FLASHINGCONTINUOUS SEALANT REV. DATE ►4I ® AT BELLYBAND TRIM,ADJUST END-DAM HEIGHT TO ALIGN WITH DECK-EDGE S�°P� ®,�, �/ FLASHING, REFER TO DETAIL 3.23 FORSr �4411 Ar SIMILAR �� 40 .,,,,T,, ��°QE ��4,1 PROJECT NAME Oe ,/,„„\,1, ,,,, p ..,,, Touchstone Townhomes lee Targeted Building 1� Enclosure Rehabilitation A1101INSTALL 24-GAUGE PRE-FINISHED% FLASHING WITH HEMMED DRIP ��� PROJECT NUMBER (R) 17-091 INSTALL 24-GAUGE BONDERIZED METAL DECK EDGE FLASHING WITH 1 140 HEMMED DRIP SET IN SEALANT BEAD SHEETNAME DECK DETAILS 6.06B WATERPROOF DECK-TO-WALL SADDLE FLASHING SHEET NUMBER INSTALL THIN-SET TILE DECK CLADDING 1" = 1i-0" TRANSITION CONDITION 2 AT PERPENDICULAR CONDITION - ISO. SEQ. 2 OF 2 OVER MORTAR BED (NOT SHOWN) 6.06B EXAMPLE OF EXISTING OBSERVED CONDITION. PHOTO DOES NOT REPRESENT COMPLETE SCHEDULED WRB, LAP SCOPE OR VARIATIONS OF CONDITIONS VER WRB AND I'UU \ OCOMPONENTS BELOW ■ ■ MI1I 1THRU-WALL FLASHING IMIIN SCHEDULED FIBER \Ii ` CEMENT PLANK LAP 2" 6IF 1 CLADDING 1 k` MIN. )i 24-GAUGE PRE-FINISHED -= METAL HEAD FLASHING (TYP)-SET ONTO CONT. -1 BEAD OF SEALANT. FILL ' VOIDS AT EDGES. '''' l''''',06.: 2" I ,MIN. ' I II WRB, LAP OVER DECK 41111 IN ,' COATING AND METAL DECK- TO WALL FLASHING BELOW. 4" ----11/2" MIN I 1/2"MIN as����e��smxa�� v sm�a�s�ogn i�a������tan�e �1.�, 5/8 "DECAY RESISTANT t"." 11/2" MIN I MOUNTING BLOCK, VERTICALLY CONTINUOUS ,.00411111 ' PRE-DRILL AND SEAL ALL NOTE: LAG BOLT PENETRATIONS 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED iI 11111 ' I WALL ASSEMBLIES. 2. TRIM TO TUCK UNDER THRU-WALL FLASHING WHERE APPLICABLE. EXISTING PLYWOOD SHEATHING 3. PREP NEW AND EXISTING TRIM AND TO REMAIN CLADDING AS REQUIRED TO RECEIVE FINISH. 4. CAREFULLY REMOVE TRIM AND CLADDING AT riiiip WRB - LAP OVER EDGE OF ELEVATION TO BE REHABILITATED. DO NOT r ,„ ____4 DECK COATING,W FLASHING DAMAGE THE EXISTING UNDERLYING WRB. AND WRB BELO NOTIFY CONSULTANT IF EXISTING WRB IS NOT PRESENT. 5. DECK SURFACE TO BE A 2%MIN. SLOPE TO DRAIN VINYL SPACER 6. INSTALL METAL BASE FLASHING AND CEMENTITIOUS DECK COATING SYSTEM IN 2" t �,w yi ,�,v',;w,t m /uax kno,' CONFORMANCE WITH MANUFACTURER'S MIN. MI I INSTRUCTIONS. LAP AND SEAL METAL .��--- EXTEND WP40 SHEET MEMBRANE FLASHING IN CONFORMANCE WITH PROJECT 2" I VERTICALLY UP WALL MIN.2"BEYOND DOCUMENTS AT CORNERS AND DOOR SILL MIN. FLASHING LEG PAN. 7. SHEET METAL FLASHING IS TO FULLY COVER P _ SAM FROM ALL UV EXPOSURE,TYPICAL. / ' ACRYLIC CEMENTITIOUS REINFORCED ,===.7.'" ' DECK COATING SYSTEM TO SLOPE,7,7..II I ALTERNATE THIN-SET TILE INDICATED OVER MORTAR BED (NOT BASE SCOPE OF WORK) I 24 GA. BONDERIZED DECK-TO-WALL I I FLASHING Ink li ...... „,.. _..,_ I I \ Yak, I I I I / -.AL_ I I 1 1 REFER TO DETAIL6.02 FOR DECK SOFFIT TO WALL CLADDING TRANSITION 7 6.07 RAIL-TO-WALL CONNECTION 3" = 1-0" AT FIBER CEMENT CLADDING/CEMENTITIOUS DECK COATING mhg m H H C m 0 0 D �� :TI �TS� v v S O (D y00 z— coDDrp- C.., .y..m m CO e0 VJ m _ �7 rii (D O O m n O n OD wAn mOEI @t' NNaa :". m 0 = -, v r a7 ,- wmm mn© yNoomp O C D 0 z v z () co H -' 6 v. m = p, 7 IZ p Neu AZo_ 55 °-“'' "M nrn D p c g c p z Z j O fit “,C�0, m e -n N N.Z I N :z m r 3 (Ps N C t� D N O — H N '^ A Cn m - CO Cr Q. = m C 00 N -.' D owrn `(D >,�O 22 °-L,4- ;V/ A —'CD 7' 7' (D N C v m a o o ro A__, :C)� Q ( n 7 N - _ FtRENSIC / BVIlOIY6 tONSW ANIS 24-GAUGE STAINLESS / STEEL FLASHING 15 82nd Drive,Suite 10 Gladstone,OR 97027 EXTEND 1" BEYOND / INSTALL \ TEL 503.772.1114 FINISH DECK EDGE ® DIVERTER, FAX:503.772.4039 / m TYP. \ www.forensicbuilding.co 6 /X CLADDING info@forensicbuilding.com 6„ / \ COPYRIGHT©2017 FORENSIC BUILDING CONSULTANTS 4" \ All Rights Reserved I 7\ OR CCB#155496 )�� PUNCH LOCKED AND I I WA FORENW C94308 UT#8334529-5501 2 SEALED OR FULLY I a" SOLDERED. 1 EXTEND DIVERTER EDGE \ FLASHING TO EXTEND / 1" PAST VERTICAL FACE \ 1/2"BELOW BOTTOM OF CLADDING \ OF FRAMING / SEAL WRB OVER VERTICAL FLASHING LEG 4' / AND SEAL ALL LAPS IN FLASHING11111%.11111 . INSET'A' 24-GAUGE FULLY SOLDERED STAINLESSDIVERTER FLASHING / REMOVE HEM AT STEEL SADDLE FLASHING REFER TO — — PERPENDICULAR JUNCTIONS TO ,, ' S ,, DETAIL 6.02A JOISTS WHERE NEEDED PRINT ALL DETAILS IN NOTCH FLASHING AS r._ COLOR AT 11x17 NECESSARY TO ACCOMMODATE CLIENT JOISTS.APPLY A BEAD OF / Association of Unit SEALANT AT THE EDGE OF 6" MIN FLASHING WHERE IT AD.TS '�� Owners of Touchstone JOISTS I Townhomes f�� � ISSUE -'44111k11111166-- 1 1 06.05.2018 �' r--1, � j ,,,, Construction Issue Set .. ,, , . . REVISIONS REV. DATE ,.. i. E .4&40111111 , ,\ PROJECT NAME .M.� Touchstone Townhomes �%k \ �' 14Niiiihk....440\ Targeted Building iEnclosure Rehabilitation k.\ PROJECT NUMBER �,� (R) 17-091 II SHEET NAME 1 � DECK DETAILS - 6.08 DECK FLASHING ASSEMBLY DIAGRAM SHEET NUMBER 3/4" = 11-0" AT TYPICAL FLOW-THROUGH DECK CONDITION - ISOMETRIC DETAIL 6,08 mhg NOTES: FORENSIC 1. CONTRACTOR TO VERIFY CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED WALL ASSEMBLIES 8 0 11 0 1 1 0 COMSOLIANIS EXISTING SHEATHING \ 2. METAL THRU WALL FLASHING IS TO BE COMPLETE WITH UPTURNED ENDS AT TERMINATIONS 1582nd Drive,Suite 10 11011 AND CONTINUOUS AROUND CORNERS Gladstone,OR 97027 TEL 503.772.1114 lill IIII 3. TREAT ALL CUT EDGES AT PRESSURE-TREATED LUMBER, INCLUDING KERF CUTS,WITH COMPATIBLE FAX 503.772.4039 SCHEDULED WRB, LAP OVER LOWER TREATMENT SOLUTION PER AMERICAN WOOD PROTECTION ASSOCIATION-AWPA M4. www.torensicbuilding.com WRB AND LEDGER FLASHING BELOW 4. LAP AND SEAL METAL FLASHING IN CONFORMANCE WITH PROJECT DOCUMENTS. nto@torensicbuilding.com 6" 4�� COPYRIGHT@2017 FORENSIC SCHEDULED PRESSURE TREATED BUILDING CONSULTANTS FURRING STRIP WITH INSECT SCREEN All Rights Reserved OR CCB#155496 AT HORIZ. TERMINATIONS, TYP. ---� 1/2" WA FORENW C94308 FIBER CEMENT PLANK LAP CLADDING UT#8334529-5501 1" CONTINUOUS SEALANT I 1 PRESSURE TREATED POST 1/2 BEYOND AT LOWER DECK 24-GAUGE STAINLESS STEEL METAL FLASHING V.I.F.jt, LEVEL AS OCCURS SET IN CONTINUOUS BEAD OF SEALANT_S REMOVE, SAFELY STORE,AND 2.. FASTEN THROUGH UP-LEG ONLY, NOTCH JOIST SCHEDULED DECK BOARDS. SEAL REINSTALL GUARDRAIL SYSTEM TO ADMIT DOWN-LEG AND SET IN CONTINUOUS ALL FASTENER PENETRATIONS BED OF COMPATIBLE SEALANT. THROUGH LEDGER FLASHING 2" II0 SCHEDULED DECK BOARDS. SEALALL —_ FASTENER PENETRATIONS THROUGH E ' LEDGER FLASHING PRINT ALL DETAILS IN 6 COLOR AT 11x17 1161"-2" , ., CLIENT ill All] i ' , A 1 % J ! � llon of Unit L . j / / % %% �A OwnersofTouchst Touchstone PRESSURE TREATED Townhomes 1111.0 � 1" 1/4 TYP DECK FRAMING ' - TYP. ISSUE 06.05.2018 Illigyil- O ° SCHEDULED LAG BOLTS AS - Construction Issue Set REQUIRED- FILL AND SEAL REVISIONS FFilllilt HOLES ---�, REV. DATEfit 2" '''''"""ImmSAM-CONTINUOUS BEHIND LEDGER , ( r� 1 MIN. EXTEND 2"BEYOND FLASHING ABOVE AND LAP 2"OVER METAL HEAD FLASHING BELOW PRESSURE TREATED DECK LEDGER BLOCKING AS REQUIRED ` 24-GAUGE PRE-FINISHED THRU-WALL FLASHING PROJECT NAME SET IN SEALANT LEDGER WITH UP-TURNED END DAMS AND HEMMED DRIP EDGE Touchstone Townhomes J h FIBER CEMENT PLANK LAP CLADDING Targeted Building Enclosure Rehabilitation SCHEDULED PRESSURE TREATED FURRING STRIP WITH INSECT SCREEN AT HORIZ. PROJECT NUMBER TERMINATIONS, TYP. (R) 17-091 SCHEDULED WRB TO EXTEND TO TOP OF LEDGER SHEET NAME PRESSURE TREATED DECK BEAM DECK DETAILS 6.09 DECK-TO-WALL FLASHING TRANSITION 6. 10 DECK EDGE FLASHING WITH GUARDRAIL SHEET NUMBER 3" = 1'-0" AT FLOW-THRU DECK ASSEMBLY 3" = 1'-0" ATTACHMENT AT WOOD FRAMED FLOW-THRU DECK ASSEMBLY 6.09 mhg mhg 6. 10 , EXAMPLE OF EXISTING OBSERVED CONDITION. PHOTO DOES NOT REPRESENT COMPLETE SCOPE OR VARIATIONS OF CONDITIONS Ili PLYWOOD SHEATHING -41 off i1la WRB, LAP OVER WRB AND SAM ,.: 1. .., . BELOW AND SEAL 7 ...., . 404. .ji 1111II PRESSURE TREATED FURRING WITH INSECT SCREENS AT TERMINATIONS SEALANT ti ,.r7;.7 .N IIIIIFIBER CEMENT LAP CLADDING 'II 24-GAUGE PRE-FINSIHED METAL HEAD ® FLA • SHING WITH END DAMS AND OMNI HEMMED DRIP EDGE SET ON I CONTINUOUS BEAD OF SEALANT. FILL 4" ► VOIDS AT EDGES WITH SEALANT 2%MI '.."-lw . p - PRESSURE TREATED FURRING BEHIND SLOP 1/2 I VERTICAL TRIM • -------L--\- 1/2" --' 1/2" L ii ;wI, -4111111111111111110141 'MI FIBER CEMENT TRIM-TERMINATE 2"ABOVE • j SURFACE OF GUARDRAIL,TYP. a SAM - FULL HEIGHT OF TRIM BLOCK 6" 4 100P WRB, LAP OVER LOWER WRB AND LEDGER FLASHING BELOW • CONTINUOUS SEALANT 1/2' LI 11" allimp.--.im . V.I.F. 24-GAUGE STAINLESS STEEL METAL FLASHING SET IN `‘ °Ill CONUOEAARH ° UP NTI-LEG ONLOUYS, NOTCH F JOISTSALTONT ADMIT-FSTEN DOWNTH-LEGOUGAND SET IN CONTINUOUS BED OF COMPATIBLE SEALANT. ''.J SCHEDULED DECK BOARDS ...000l . d NOTE: 1. CONTRACTOR TO VERIFY CLEARANCE a _s,c REQUIREMENTS AND MAINTAIN ALL RATED 7 1 WALL ASSEMBLIES. =� \ �j/7 /�� 2. INSTALL METAL DECK-TO-WALL FLASHING, II j �� DECK FRAMING IN CONFORMANCE WITH I 1Wl/ jjj� / j/,� j7j PROJECT DOCUMENTS AND 1 I . 1 MANUFACTURER'S INSTRUCTIONS. SEAL ALL METAL FLASHING LAPS, CORNERS,AND III ` 7 I . EDGES. 3. CAREFULLY REMOVE TRIM AND SIDING AT Vv ELEVATION TO BE REHABILITATED. DO NOT o DAMAGE THE EXISTING UNDERLYING WRB. I NOTIFY CONSULTANT IF EXISTING WRB IS 1 NOT PRESENT. I I , 0 4. TRIM AND SIDING TO BE INSTALLED IN CONFORMANCE WITH MANUFACTURER'S I I . INSTRUCTIONS I 1 5. TREAT ALL CUT EDGES AT PRESSURE- i , ` TREATED LUMBER, INCLUDING KERF CUTS, r x WITH COMPATIBLE TREATMENT SOLUTION . i PER AMERICAN WOOD PROTECTION REFER TO DETAIL6.09 FOR DECK ASSOCIATION-AWPA-U1. i • I I LEDGER CLADDING TRANSITION 6. SHEET METAL FLASHING IS TO FULLY COVER ASSEMBLY SAM FROM ALL UV EXPOSURE. ---PV--- , i 6. 11 DECK RAIL-TO-WALL FLASHING TRANSITION 3" . 1'-0" AT FIBER CEMENT CLADDING AND FLOW-THRU DECK ASSEMBLY mhg ! o A0 O C7 f0/1 co' 3 __-- N n Z C D r.Z{1 ° m 0 u, ®. _ AO C (O N o C O H O O p H -1T A 00 (-. Dm an°Di 10. N r o O X r _ �0) m m - m - O O m R. O p D #wOc'� �� m 'm �,cn o n —1 � XI o_ n m < O COTe v. g .ZlF- AmmOp `FA ,,,omo• .m C > 0 Z V Z X07 - Z 5 _ N m O 7 -Di 0 � s, <,2 c c ��Om p Q Q J V �� m C- 3 co 3 N C 5 D m y O' B C 0 - -I NC�cn m C� naA� ooc _rri m m m 6 Q 0 m C W CD ' D o a,c, if,< H o ,o. o-,0- -V N O (D N 0 = y r o'o' aZz 3 3 0 ,, ,,,,,_,'m J O -C) o B co = z c O CD CD NOTES: EXAMPLE OF EXISTING OBSERVED CONDITION. EXAMPLE OF EXISTING OBSERVED CONDITION. FORENSIC 1. CONTRACTOR TO VERIFY CLEARANCE PHOTO DOES NOT REPRESENT COMPLETE PHOTO DOES NOT REPRESENT COMPLETE 8 4 I t B I Y C C C tl S O l I A N I S REQUIREMENTS AND MAINTAIN ALL RATED SCOPE OR VARIATIONS OF CONDITIONS SCOPE OR VARIATIONS OF CONDITIONS 1582nd Drive,Suite 10 WALL ASSEMBLIES .." Gladstone,OR 97027 ,� ' w �"`,. TEL:503.772.1114 2. METAL THRU WALL FLASHING IS TO BE FAX 503 772.4039 -. www.forensicbuilding.com COMPLETE WITH UPTURNED ENDS AT ,A *r' �'� C� TERMINATIONS AND CONTINUOUS AROUND info forensicbuilding.corn ` + CORNERS �� !'1111 ` COPYRIGHT CONSUL2017 FORENSIC 3. SHEET METAL FLASHING IS TO ;*t4olrIlk �rt BUILDING CONSULTANTS r ■ '^ All Rights Reserved COVER SAM FROM ALL UV EXPOSURE - (�il It j' OR CCB#155496 ,���,�- ��, .aA WAFORENWC94308 4. THREE-DIMENSIONAL DRAWINGS ARER iiiI = UT#8334529-5501 INTENDED TO ILLUSTRATE SPECIFIC x 11110P �_. ----..s„,_,.,.:.,:._..„ Ir. CONCEPTS OF COMPONENTS ` r INSTALLATION. NOT ALL ASSEMBLY COMPONENTS ARE SHOWN fir' PRINT ALL DETAILS IN COLOR AT 11x17 CLIENT 24-GAUGE PRE-FINISHED METAL HEAD FLASHING WITH UP-TURN END DAM, (TYP) Association of Unit SET ON CONT. BEAD OF SEALANT AND FILL Owners of Touchstone VOIDS AT EDGES. REFER TO DETAIL6.07 Townhomes AND 6.11 I ISSUE 06.05.2018 14, Construction Issue Set 41 ..• EXISTING GUARDRAIL TO BE REMOVED REVISIONS AND REINSTALLED REV. DATE i 0 I 00 II Ij I 0 Ili PROJECT NAME �i 11Touchstone Townhomes Witt ' Targeted Building Enclosure Rehabilitation PROJECT NUMBER FILLET BEAD OF SEALANT, TYPICAL I EACH SIDE II II II CONTINUOUS VERTICAL FIBER CEMENT (R) 17091 MOUNTING BLOCK, FOR RAIL ATTACHMENT. SHEET NAME PRE-DRILL AND SEAL ALL PENETRATIONS, DECK TYPICAL, REFER TO DETAIL6.07 AND 6.11 DETAILS 6. 12 WALL INTEGRATION OF DECK RAIL ASSEMBLY SHEET NUMBER 1" = 1'-O' AT FIBER CEMENT LAP CLADDING - ISOMETRIC DETAIL 6. 12 mhg