Loading...
Plans (259) mit k-)--PDS (. v,2-) -"W,ctx\ Milek® MiTek USA, Inc. 7777 Greenback Lane Suite 109 Citrus Heights,CA,95610 Telephone 916/676-1900 Re: PL15-398_UPPER Fax 916/676-1909 POLYGON The truss drawing(s)referenced below have been prepared by MiTek USA,Inc.under my direct supervision based on the parameters provided by Pacific Lumber&Truss Co.. Pages or sheets covered by this seal: R45996168 thru R45996176 My license renewal date for the state of Oregon is June 30,2017. Lumber design values are in accordance with ANSUTPI 1 section 6.3 These truss designs rely on lumber values established by others. OFFS •5 �NGI NFF� `S/ C• o 87022PE 9r N y �Aj, OREGON etc?AUU Lb 'ER A. HEv' le EX' '' :06/30/ it November 30,2015 Hernandez,Marcos The seal on these drawings indicate acceptance of professional engineering responsibility solely for the truss components shown. The suitability and use of this component for any particular building is the responsibility of the building designer,per ANSUTPI 1. Job Truss Truss Type Qty Ply POLYGON R45996168 PL15-398 UPPER F01 FLOOR 9 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MTek Industries,Inc.Fri Nov 27 10:55:55 2015 Page 1 ID:zs2ygYHMYlt1_Z1 p9y12t1 yAg??-C2lotXC6_hwKV1 DU3AVpf6uLN?I8tNil8m FYHYyEz2 1 1-8-12 1 1 1-4-10 I 2-0-0 1 1 1-2-0 II 1-1-10 I I 1-3-8 I 1-3-0 1 Scale=1:37.2 3x5 = 1.5x3 I I 4x8 = 3x6= 1.5x3 I I 3x4= 1.5x3 I I 3x4= 3x4= 1.5x3 II 3x6 FP= 3x4 I I 3x4= 1.5x3 I I 1 2 3 4 5 6 7 8 9 e10 11 12 13 14 N �� e a \ a a0 0e a m :\e.. II a l'i'o ... 24 23 22 21 20 19 18 17 16 15 4x5= 3x6= 3x6 FP= 3x5= 1.5x3 I I 1.5x3 I I 3x6= 3x8= 3x4= 3x8= 13-0-6 1 1-11-12 i 11-10-6 12-5-661 I 18-6.8 I 21-4-0 I 1-11-12 9-10-10 X7-0 b-7-0 5-6-2 2-9-8 Plate Offsets(X,Y)— [2:0-3-0,Edge],[7:0-1-8,Edge],[8:0-1-8,Edge],[24:Edge,0-1-8] LOADING(psf) SPACING- 1-7-3 CSI. DEFL- in (loc) Udefl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.24 Vert(LL) -0.10 19-20 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.31 Vert(TL) -0.15 19-20 >999 360 BCLL 0.0 Rep Stress Inc: YES WB 0.90 Horz(TL) 0.01 16 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:100 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF 2400F 2.OE(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF 2400F 2.OE(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (lb/size) 15=394/Mechanical,24=-784/Mechanical,23=1695/0-7-0,16=1348/0-5-8 Max Uplift 15=480(LC 6),24=-844(LC 6) Max Gray 23=1697(LC 3),16=1349(LC 4) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=0/1551,3-4=-444/0,4-5=-444/0,5-6=-1444/0,6-7=-1444/0,7-8=-1245/0, 8-9=761/0,9-10=-761/0,10-11=761/0,11-12=0/1306,12-13=0/1302 BOT CHORD 23-24=-1551/0,22-23=-598/0,21-22=-598/0,20-21=0/1094,19-20=0/1245, 18-19=0/1245,17-18=0/1245,15-16=-624/0 WEBS 2-23=1010/0,2-24=0/1766,7-20=101/330,5-20=0/393,5-21=-728/0,3-21=0/1165, 3-23=-1168/0,11-16=-1367/0,11-17=0/942,8-17=-673/0,13-15=0/796,13-16=-921/0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Refer to girder(s)for truss to truss connections. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4)CAUTION,Do not erect truss backwards. � ,4GP SFR s�° Qf 87022PE vr- 01..6461.4.404 N 5.-7 �Aj, OREGO q,° �U� 90 BER '\� �O OS A. HECk EXPIRES:06/30/2017 November 30,2015 4 t ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERANCE PAGE MII-7473 rev.10/032015 BEFORE USE. �Q Design valid for use only with MTan ek®connectors.This design 6 based only upon parameters shown,and is for individual building coponent,not a truss system.Before use,the building designer must verity the applicability of design parameters and properly incorporate this designminto the overall AA !' building design. Bracing indicated is to prevent bucking of individual truss web and/or chord members only.Additional temporary and permanent bracing MITek is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/]P11 Quality Criteria,DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45996169 PL15-398_UPPER F02 Floor 10 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Fri Nov 27 10:55:57 2015 Page 1 ID:zs2ygYHMYItI_Z1 p9y12t1 yAg??-8RtYIDEM WJA2kLNsBaXHkXzecpMrLNVbc4keMRyEzrO 1 1-0.0 1 1 1-1-10 1 1 1-2-0 11)-7-21 I 1-2-0 I 1-2-0 I I 1-2-0 1 1-2-0 i Scale=1:33.9 4x4= 3x4= 3x4= 3x4= 3x4= 3x4= 3x4= 3x4= 4x4= 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 ir„, ‘71; -../NI I I I I I r. NI I 1 W NIIII I r Nir \lir Nish.- .,w„,,.:N e e o 0 0 -e o o e 30 29 28 27 26 25 24 23 22 21 3x4 = 4x5= 3x5= 3x5= 3x5— 3x5= 3x4= 3x5= 4x6 = 3x4= 14-2-2 I 13-0-2 13-7-2 I 19-11-4 I 13-0-2 0-7-0 b-7-0 5-9-2 Plate Offsets(X,Y)— 114:0-1-8,Edge],[24:0-1-8,Edge] LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) I/deft Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.45 Vert(LL) -0.31 24-25 >756 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.61 Vert(TL) -0.49 24-25 >482 360 BCLL 0.0 Rep Stress Incr YES WB 0.56 Horz(TL) 0.07 20 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:99 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF 2400F 2.OE(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF 2400F 2.OE(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 30=871/Mechanical,20=871/0-4-4 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-1588/0,3-4=-1588/0,4-5=-2786/0,5-6=-2786/0,6-7=-3608/0,7-8=-3608/0, 8-9=-4042/0,9-10=-4042/0,10-11=-4122/0,11-12=-4122/0,12-13=-3586/0, 13-14=-3586/0,14-15=3053/0,15-16=-3053/0,16-17=-1806/0,17-18=-1806/0 BOT CHORD 29-30=0/843,28-29=0/2232,27-28=0/3242,26-27=0/3871,25-26=0/4132,24-25=0/3999, 23-24=0/3586,22-23=0/3586,21-22=0/2507,20-21=0/970 WEBS 14-23=0/364,2-30=1181/0,2-29=0/1042,4-29=-903/0,4-28=0/776,6-28=-639/0, 6-27=0/513,8-27=-367/0,12-24=-662/7,18-20=-1271/0,18-21=0/1096,16-21=-919/0, 16-22=0/716,15-22=-31/252,14-22=1052/0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)All plates are 1.5x3 MT20 unless otherwise indicated. 3)Refer to girder(s)for truss to truss connections. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. Ck C��co� .4G N- `i-, 2 �� 87022PE 9t nr 7 oAj, OREGO cyo �N 9O `iii 1\ �O �`.1 A. HECk EXPIRES:06/30/2017 November 30,2015 I, ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERANCE PAGE MII.7473 rev.10/03/2015 BEFORE USE. Mill Design valid for use only with Mitek®connectors.Th6 design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall i� building design.Bracing indicated is to prevent bucking of individual truss web and/or chord members only.Additional temporary and permanent bracing Mi/T Qtly is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45996170 PL15-398_UPPER F03 Floor 2 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MTek Industries,Inc.Fri Nov 27 10:55:58 2015 Page 1 ID:zs2ygYHMYItL_Z1 p9y12t1 yAg??-cdRxWZF_GcivMVy2112 WHIWp2Dne4k9lgkTCutyEzr? 1 1-6-0 1 1-3-4 1 1 1-1-10 1 1-0-0 1 1 1-2-0 IIS Scale=1:38.1 3x4= 4x8 = 3x4 I I 4x4= 3x5= 3x4= 3x4= 3x4- 3x4= 3x6 FP= 3x4 = 3x4= 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 e Nl1_ 'u/ '\ � / \ � /N '�'\ / /N / N /-\ / -N I2 e -[s- o i o e 0 OM 35 34 33 32 31 30 29 28 27 26 25 24 23 4x5= 3x8= 4x6=3x6 FP=4x5= 3x5= 3x5= 3x4= 3x5= 3x5 = 3x5= 3x4 = 14-0-14 1 3-0-4 I 12-10-14 1 -5-14 1 22-4-12 3-0-49-10-10 7-0 7-0 8-3-14 Plate Offsets(X,Y)- [12:0-1-8,Edge],[27:0-1-8,Edge],[35:Edge,0-1-8] LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.34 Vert(LL) -0.16 27 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.32 Vert(TL) -0.25 27 >941 360 BCLL 0.0 Rep Stress Incr YES WB 0.91 Horz(TL) 0.02 23 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:112 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF 2400F 2.0E(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF 2400F 2.0E(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing:34-35,33-34,31-33. REACTIONS. (lb/size) 23=693/Mechanical,34=2158/0-7-0,35=-893/0-2-4 Max Uplift35=984(LC 4) Max Gray 23=693(LC 4),34=2158(LC 1) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=0/2846,3-4=0/2846,4-5=0/872,5-6=0/872,6-7=-574/0,7-8=-574/0,8-9=-1631/0, 9-10=-1631/0,10-11=-2296/0,11-12=-2296/0,12-13=-2565/0,13-14=-2565/0, 14-15=-2528/0,15-16=-2528/0,16-17=-2528/0,17-18=-2064/0,18-19=-2064/0, 19-20=-1227/0,20-21=-1227/0 BOT CHORD 34-35=-1498/0,33-34=1735/0,30-31=0/1148,29-30=0/2013,28-29=0/2565, 27-28=0/2565,26-27=0/2603,25-26=0/2342,2425=0/1690,23-24=0/663 WEBS 2-35=0/1800,2-34=-1780/0,12-29=-548/0,10-29=0/396,10-30=-537/0,8-30=0/677, 8-31=-804/0,6-31=0/946,6-33=1070/0,4-33=0/1208,4-34=-1446/0,21-23=-928/0, 21-24=0/790,19-24=-649/0,19-25=0/523,17-25=-389/0,17-26=0/261,14-27=-266/229 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)All plates are 1.5x3 MT20 unless otherwise indicated. 3)Refer to girder(s)for truss to truss connections. ,,.0P R OFF 4)Provide mechanical connection(by others)of truss to bearing plate at joint(s)35. 4\<c.." G Ss' 5)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to ��"c. �N FR 02 be attached to walls at their outer ends or restrained by other means. p 6)CAUTION,Do not erect truss backwards. 87022PE r / N y �Aj, OREGON rye 4v/ 9O `M$ER 1,� r �`9 A. HERCP EXPI RES:06/30/2017 November 30,2015 1 H ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERANCE PAGE MII-7473 rev.10/032015 BEFORE USE. 1111. Design valid for use only with MTeksE connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and property incorporate this design into the overall p� building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing IYtaTekx is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TP11 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45996171 PL15-398_UPPER F04 FLOOR 3 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MTek Industries,Inc.Fri Nov 27 10:55:59 2015 Page 1 ID:zs2ygYHMYItIf_1�Z111 p9y12t1 yAg??-4q_JjvGd 1 wQmzfxFl?ZIpy3?Cc7vpDxu3ODIQJyEzr 1 1-3-0 1 1-5-0 11 1-5-6 1 2-0-0 I 1 1-7-0 1,a Scale=1:37.1 3x4= 1.5x3 II 4x6= 3x4 I I 3x10= 1.5x3 II 3x4= 1.5x3 II 3x4= 1.5x3 II 3x6 FP= 1.5x3 II 3x4= 1.5x3 II 1 /`2 3 4 5 6 7 8 9 10 11 12 13 14 o e 1 la' 23 22 21 20 19 18 17 16 15 4x5 = 3x8= 3x6 FP= 3x10 = 3x6= 1.5x3 II 3x4= 3x6= 3x4= 1 2-11-0 I 21-3-0 2-11-0 18-4-0I Plate Offsets(X,Y)— 18:0-1-8,Edge],117:0-1-8,Edge],f23:Edge,0-1-81 LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) 1/defl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.31 Vert(LL) -0.14 18 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.25 Vert(TL) -0.21 18 >999 360 BCLL 0.0 Rep Stress Inc: YES WB 0.82 Horz(TL) 0.02 15 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:98 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF 2400F 2.0E(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF 2400F 2.0E(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing:22-23,20-22. REACTIONS. (lb/size) 15=657/Mechanical,22=2013/0-5-8,23=-812/Mechanical Max Uplift23=-902(LC 4) Max Gray 15=657(LC 4),22=2013(LC 1) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 2-3=0/2515,3-4=0/2515,4-5=-251/0,5-6=-251/0,6-7=-1993/0,7-8=1993/0, 8-9=-2337/0,9-10=2337/0,10-11=-1912/0,11-12=-1912/0,12-13=-1912/0 BOT CHORD 22-23=1154/0,21-22=-1215/0,20-21=1215/0,19-20=0/1270,18-19=0/2337, 17-18=0/2337,16-17=0/2293,15-16=0/1139 WEBS 2-23=0/1474,2-22=1729/0,8-19=-553/0,6-19=0/810,6-20=-1172/0,4-20=0/1608, 4-22=-1567/0,13-15=-1276/0,13-16=0/866,10-16=-427/0,10-17=-159/302 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Refer to girder(s)for truss to truss connections. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4)CAUTION,Do not erect truss backwards. '(( O PRo1 c:5 ENGIN F"r io 870 2PE /9r* i 7 NvcV -0j, OREGON c wN "5)O FMBER \� .r �S A. HE# EXPIRES:06/30/2017 November 30,2015 f H ®WARNING-Verify design parameters and READ NOTES ON THOS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev.10/03/2016 BEFORE USE. Design valid for use only with Miler&connectors.The design is based only upon parameters shown,and is for an individual building component,not � a truss system.Before use,the building designer must verify the appfcability of design parameters and properly incorporate the design into the overall T __Q building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing Miler' is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TP11 Quality Criteria,DSB-89 and SCSI Building Component 7777 Greenback Lane Safely information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45996172 PL15-398_UPPER F05 Floor 8 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc. Fri Nov 27 10:56:01 2015 Page 1 ID:zs2ygYHMYItL_Z1 p9y12t1 yAg??-0C638bHtZXgTDygdQQbDuNSHVQikHAIBWiisUCyEzgy 1 1-0.0 1 04 iti 1�-i p-7-7i 1 1-2-0 1 1-2-0 I I 1-2-0 1 1-2-0 1 Scale=1:36.4 4x4-4x4= 3x4= 3x4= 3x4= 3x4= 3x4= 3x6 FP= 3x4= 3x4= 4x5= 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 18 17 18 19 20 21 22 • \e � a • a a o o- �, a ® e o N - e N 0 O O B D TILL. O O O s-e l'-9 35 34 33 32 31 30 29 28 27 26 25 24 23 3x4= 4x6= 3x6=3x6 FP=3x5= 3x5= 3x5= 3x5= 4x4= 3x5= 4x6= 3x4 = 1.5x4 SP= 15-6-14 14-4-14 14-11-1 I 21-4-0 I I 14-4-14 0-7-0 0.7-0 5-9-2 Plate Offsets(X,Y)- (17:0-1-8,Edge],(27:0-1-8,Edge] LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.52 Vert(LL) -0.40 29 >641 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.68 Vert(TL) -0.62 29 >410 360 BCLL 0.0 Rep Stress Incr YES WB 0.60 Horz(TL) 0.09 23 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:107 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF 2400F 2.0E(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF 2400F 2.0E(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 23=933/0-4-4,35=933/Mechanical FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-1712/0,3-4=-1712/0,4-5=-3036/0,5-6=-3036/0,6-7=-3981/0,7-8=-3981/0, 8-9=4547/0,9-10=-4547/0,10-11=-4727/0,11-12=-4727/0,12-13=-4554/0, 13-14=-4554/0,14-15=-4554/0,15-16=3935/0,16-17=-3935/0,17-18=3339/0, 18-19=-3339/0,19-20=-1950/0,20-21=-1950/0 BOT CHORD 34-35=0/905,33-34=0/2419,32-33=0/3553,31-32=0/3553,30-31=0/4309,29-30=0/4682, 28-29=0/4688,27-28=0/4254,26-27=0/3935,25-26=0/3935,24-25=0/2723,23-24=0/1042 WEBS 16-27=0/550,17-26=0/389,2-35=-1268/0,2-34=0/1130,4-34=-990/0,4-33=0/864, 6-33=-724/0,6-31=0/598,8-31=-460/0,8-30=0/334,12-28=-255/55,15-28=0/498, 15-27=885/0,21-23=-1366/0,21-24=0/1190,19-24=1014/0,19-25=0/807, 18-25=-20/270,17-25=-1150/0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)All plates are 1.5x3 MT20 unless otherwise indicated. 3)Refer to girder(s)for truss to truss connections. 4)Required 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be �ck0 PR OFFS, attached to walls at their outer ends or restrained by other means. �� ANG]N��9 6-> 87022PE r N 457 OREG•N ti 9O FA& � OS A. HEEA 1V�P EXPIRES:06/30/2017 November 30,2015 B 1 WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERANCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. l: Design valid for use only with Mtrek0 connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated a to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/1811 Quality Criteria,DSB-89 and BCSI Building Component Suite 109 Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45996173 PL15-398_UPPER F06 Floor 2 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Fri Nov 27 10:56:02 2015 Page 1 ID:zs2ygYHMYIIt1_Z1 p9y12t1 yAg??-UPgRLxIVKroKg6Fq_87SRbhVvg7K0YoKIMRPOeyEzgx 1 1-6-0 1 1-3-4 1 1 1-1-10 1 1-0-0 1 1 1-2-0 1 r- ' r2_( Scale=1:38.5 3x4 = 4x8= 3x4 I I 4x5= 4x4= 3x4= 3x4= 3x4= 3x4= 3x6 FP= 3x4= 3x4= 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 Nla' c ❑ ee 0 0 35 34 33 32 31 30 29 28 27 26 25 24 23 4x5 = 3x8 = 3x6 FP= 4x5= 3x5= 3x5 = 3x4= 3x5= 3x5= 3x5= 3x4=- 4x6 4x6 = 14-0-14 Sod I 12-10-14 15-11A7-0 1 22-7-0 I 3-04 9-10-10 8-6-10 0-7-0 Plate Offsets(X,Y)- [12:0-1-8,Edge],[27:0-1-8,Edge],[35:Edge,0-1-8] LOADING(psf) SPACING- 1-7-3 CSI. DEFL- in (loc) I/defl L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.35 Vert(LL) -0.17 27 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.34 Vert(TL) -0.26 26-27 >899 360 BCLL 0.0 Rep Stress Ina YES WB 0.94 Horz(TL) 0.03 23 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:113 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF 2400F 2.0E(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF 2400F 2.0E(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing:34-35,33-34,31-33. REACTIONS. (lb/size) 23=701/0-2-12,34=2195/0-7-0,35=-917/0-2-4 Max Uplift35=1009(LC 4) Max Gray 23=702(LC 4),34=2195(LC 1) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=0/2915,3-4=0/2915,4-5=0/915,5-6=0/915,6-7=555/0,7-8=-555/0,8-9=-1636/0, 9-10=-1636/0,10-11=-2324/0,11-12=-2324/0,12-13=2618/0,13-14=2618/0, 14-15=-2578/0,15-16=-2578/0,16-17=-2578/0,17-18=-2096/0,18-19=-2096/0, 19-20=-1244/0,20-21=-1244/0 BOT CHORD 34-35=1534/0,33-34=-1790/0,30-31=0/1141,29-30=0/2031,28-29=0/2618, 27-28=0/2618,26-27=0/2665,25-26=0/2384,2425=0/1715,23-24=0/671 WEBS 2-35=0/1844,2-34=-1820/0,12-29=-579/0,10-29=0/411,10-30=-553/0,8-30=0/694, 8-31=-821/0,6-31=0/963,6-33=-1086/0,4-33=0/1225,4-34=-1464/0,21-23=-940/0, 21-24=0/801,19-24=-661/0,19-25=0/534,17-25=-402/0,17-26=0/273,1427=-268/229 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)All plates are 1.5x3 MT20 unless otherwise indicated. 3)Provide mechanical connection(by others)of truss to bearing plate at joint(s)23,35. cc_d P R QFE 4)This truss has large uplift reaction(s)from gravity load case(s).Proper connection is required to secure truss against upward movement <G S' at the bearings.Building designer must provide for uplift reactions indicated. ,., <Y [NER s,O2 5)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to p be attached to walls at their outer ends or restrained by other means. Q 870 2P E r' 6)CAUTION,Do not erect truss backwards. 7 tP rN �'0j, OREG N ti� SUN 9(In qq$ER .\\ .�O S A. HE'ik EXPI RES:06/30/2017 November 30,2015 t WARNING-Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev.10/032015 BEFORE USE. Design valid for use only with Miteke connectors.This design is based only upon parameters shown,and is for an individual building component,not I4 a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing Mitek' is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Quality Criteria,DSB-89 and BCSI Building Component Suite 109 Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45996174 PL15-398 UPPER F07 Floor 2 1 Job Reference(optional) Pacific Lumber 8 Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Fri Nov 27 10:56:04 2015 Page 1 ID:zs2ygYHMYItI_Z1 p9y12t1 yAg??-RnoCmcJIsS224QPC5Z9wWOmgUdkyUYzdDfwW5XyEzgv 10-10-0 1 l5 1 1.2-0 1 p-7-19 1 0-9-0 10-9-0 110.9-0 1 0-9-0 110-9-0 10-9-0 1 Scale=1:34.3 3x4= 4x4= 4x4= 3x4= 3x4 = 3x4 = 3x4= 3x4= 3x6 FP= 3x4= 3x4= 3x4= 4x4 = 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 o , o a o o a e ® o a c N , � /\ /-.\_/..\_/,\_/..\_/\ -/ \_/^\_/.N_/ \ TN I e e e e -ni - e - o 0 0 0 - e 1 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 3x4= 4x5= 3x6= 3x6 FP= 3x5= 3x5= 3x5= 4x5= 3x5= 3x6= 4x5= 3x4= 1.5x4 SP= 3x5= 14-4-14 I 13-2-14 1p-9-141 20-2-0 13-2-14 b-7-0b-7.0 1 5-9-2 1 Plate Offsets(X,V)- j17:0-1-8,Edge],[18:0-1-8,Edge] LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) 1/deft Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.40 Vert(LL) -0.32 33 >759 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.65 Vert(TL) -0.50 33-34 >485 360 BCLL 0.0 Rep Stress Incr YES WB 0.51 Horz(TL) 0.07 26 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:108 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF 2400F 2.0E(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF 2400F 2.0E(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (1b/size) 26=881/0-4-4,40=881/0-2-12 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-1379/0,3-4=1379/0,4-5=-2483/0,5-6=-2483/0,6-7=-3317/0,7-8=-3317/0, 8-9=3881/0,9-10=-3881/0,10-11=4177/0,11-12=-4177/0,12-13=-4200/0, 13-14=-4200/0,14-15=-3978/0,15-16=-3978/0,16-17=-3978/0,17-18=-3617/0, 18-19=-3075/0,19-20=-3075/0,20-21=-2299/0,21-22=-2299/0,22-23=-1261/0, 23-24=-1261/0 BOT CHORD 39-40=0/725,38-39=0/1964,37-38=0/2933,36-37=0/3632,35-36=0/3632,34-35=0/4062, 33-34=0/4221,32-33=0/4113,31-32=0/3617,30-31=0/3617,29-30=0/3617,28-29=0/2730, 27-28=0/1808,26-27=0/660 WEBS 17-31=-412/0,18-30=0/367,2-40=1112/0,2-39=0/1003,4-39=-897/0,4-38=0/796, 6-38=-690/0,6-37=0/590,8-37=-483/0,8-35=0/383,10-35=-277/0,24-26=-1072/0, 24-27=0/977,22-27=-890/0,22-28=0/798,20-28=-701/0,20-29=0/560,14-32=-268/42, 16-32=-317/0,17-32=0/880,18-29=-1017/0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)All plates are 1.5x3 MT20 unless otherwise indicated. �_c,D PR Ofik- 3)Provide mechanical connection(by others)of truss to bearing plate at joint(s)40. Co'• SS' 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to �,� ', f N'F,9 /Q be attached to walls at their outer ends or restrained by other means. .� 870 2PE 1-- 0 N N 7 -0j, OREG N 19 OzN "PO AMBER 1\ n`SA. HES; EXPIRES:06/30/2017 November 30,2015 An WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MAM7473 rev.10/03/2015 BEFORE USE. Design valid for use only with Mirek®connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing Milek` is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Qualify Criteria,DSB-89 and BCSI Building Component Safety information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45996175 PL15-398_UPPER F08 Floor 1 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc. Fri Nov 27 10:56:05 2015 Page 1 ID:zs2ygYHMYItl_Z1 p9y12t1 yAg??-v_MayKNdmAvia_PfGg93DJ2719nCzgmRJg4dzyEzqu 1 1-6-0 1 1-3-4 1 1 1-4-10 1 2-0-0 1 1 1-7-0 11 1-1-10 1 1 1-3-11 1 1-3-0 1 Scale=1:39.1 1.5x3 II 1.5x3 II 3x5= 3x6= 1.5x3 II 1.5x3 II 3x6 FP= 3x5 = 1.5x3 II 2 3 4 5 6 7 8 9 10 11 12 13 14 15 11,41, ''.I' .4110. 111.1•111..110/ 1111111....41.011111111111111111111111111111111111111111111111111111 Wlill1111111111111111111111M11116 jil,LIR dIAIIIIIIIIIN. 25 24 23 22 21 20 19 18 17 16 3x6= 3x6 FP= 3x8= 3x5 = 1.5x3 II 1.5x3 II 3x6= 3x8 = 14-0-14 I 3-0i 1 12-10-14 1$-5-1 •-7-0 22-4-11 3-0-4 9-10-10 8-7-0 4 �� 5-6-2 I 2-9-11 1 0-7-0 Plate Offsets(X,Y)- [8:0-1-8,Edge],[9:0-1-8,Edge] LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (lac) 1/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.22 Vert(LL) -0.09 20-21 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.29 Vert(TL) -0.14 20-21 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.61 Horz(TL) 0.01 17 n/a n/a BCDL 5.0 Code IBC2012JTP12007 (Matrix) Weight:105 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF 2400F 2.0E(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF 2400F 2.0E(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (lb/size) 16=371/0-3-12,24=1523/0-7-0,25=-504/0-4-4,17=1310/0-5-8 Max Uplift 16=-458(LC 6),25=-596(LC 6) Max Gray 24=1524(LC 3),17=1312(LC 4) FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=0/1761,3-4=0/1762,4-5=-298/0,5-6=298/0,6-7=-1358/0,7-8=-1358/0, 8-9=-1201/0,9-10=-749/0,10-11=-749/0,11-12=-749/0,12-13=0/1257,13-14=0/1254 BOT CHORD 24-25=-917/0,23-24=-779/0,22-23=779/0,21-22=0/979,20-21=0/1201,19-20=0/1201, 18-19=0/1201,16-17=-597/0 WEBS 2-25=0/1103,2-24=-1148/0,8-21=-122/284,6-21=0/426,6-22=-764/0,4-22=0/1198, 12-17=-1333/0,12-18=0/910,4-24=-1200/0,9-18=-634/0,14-16=0/762,14-17=-892/0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)All plates are 3x4 MT20 unless otherwise indicated. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4)CAUTION,Do not erect truss backwards. �� _co P R OPFS1S ��5 �NG[N4-, WO 87022PE 144 9<' / g. N ,(V 7 f<% 1.... OREGON tit <N 9O ‘iii On 'S �`S A. H ERCP EXPIRES:06/30/2017 November 30,2015 1 N t WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE AM-7473 rev.10/032 E.015 BEFORE USDesign valid for use only with MiTek0 connectors.This design is based only upon parameters shown,and is for an individual buildingcomponent,not p a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Qualify Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45996176 PL15-398_UPPER F09 Floor 1 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MTek Industries,Inc.Fri Nov 27 10:56:07 2015 Page 1 ID:zs2ygYHMYItl_Z1 p9y12t11 yAg??-rMTKPeMe9NQdxt8nmhid8e0LYrlYguc3vd9AiryEzgs 10^ 10-8-4 I I 1-2-0 11"7=1"1 10-90 10-9-0 110-9-0 10-9-0 110-9-0 I0-&0 I Scale=1:34.8 3x4= 4x4= 3x4= 3x4= 3x4= 3x4= 3x4= 3x6 FP= 4x4= 3x4= 3x4= 4x4= 4x4= 1 2 3 4 5 6 7 8 9 10 11 12 13 1415 16 17 18 19 20 21 22 23 24 25 e e '. e /`!./.\.29/\,/,\2/-\1/49/\2/ o i, Na �, ` e�„�2N1e 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 3x4= 4x5= 3x6 FP=3x5= 3x5= 3x5 = 3x5= 4x5 = 3x5= 4x5= 4x5 = 3x4= 1.5x3 SP= 3x6= 14-7-12 I 13-5-12 1114-0-91 20-4-13 I 13-5-12 7-0 0-7-0 5-9-2 Plate Offsets(X,Y)- [17:0-1-8,Edge],[18:0-1-8,Edge] LOADING(psf) SPACING- 1-7-3 CSI. DEFL- in (loc) 1/defl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.42 Vert(LL) -0.33 33 >731 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.65 Vert(TL) -0.52 33-34 >468 360 BCLL 0.0 Rep Stress Incr YES WB 0.52 Horz(TL) 0.08 26 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:109 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF 2400F 2.0E(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF 2400F 2.OE(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 26=892/0-4-4,40=892/0-4-0 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-1397/0,3-4=-1397/0,4-5=-2518/0,5-6=2518/0,6-7=3371/0,7-8=-3371/0, 8-9=-3953/0,9-10=3953/0,10-11=-4267/0,11-12=-4267/0,12-13=4306/0, 13-14=-4306/0,14-15=-4116/0,15-16=-4116/0,16-17=-4116/0,17-18=3686/0, 18-19=3121/0,19-20=-3121/0,20-21=-2331/0,21-22=-2331/0,22-23=-1277/0, 23-24=1277/0 BOT CHORD 39-40=0/734,38-39=0/1990,37-38=0/2977,36-37=0/2977,35-36=0/3694,34-35=0/4142, 33-34=0/4318,32-33=0/4228,31-32=0/3686,30-31=0/3686,29-30=0/3686,28-29=0/2770, 27-28=0/1832,26-27=0/668 WEBS 17-31=-355/0,18-30=0/383,2-40=-1126/0,2-39=0/1017,4-39=-910/0,4-38=0/810, 6-38=-704/0,6-36=0/603,8-36=-496/0,8-35=0/396,10-35=291/0,16-32=281/0, 17-32=0/823,24-26=-1086/0,24-27=0/990,22-27=-904/0,22-28=0/812,20-28=-713/0, 20-29=0/570,18-29=-1057/0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)All plates are 1.5x3 MT20 unless otherwise indicated. (5`Ed PR OFFS 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to ]N s� be attached to walls at their outer ends or restrained by other means. �� �NG ESR 0jL kc 870 2 P E y1-- SAT GREG \\\s.........._.__..)-4;7t, AMBER � �`S A. HE EXPIRES:06/30/2017 November 30,2015 1 1 ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev.1W03/2015 BEFORE USE. l9 Design valid for use only with MiTeks connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate tho design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing Milet is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Quality Criteria,DSB-89 and BCSI Building Component Suite 109 Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suites Heights,CA 95610 Symbols Numbering System General e Notes PLATE LOCATION AND ORIENTATION 1 6-4-8 dimensions shown in ft-in-sixteenths Failure to Follow Could Cause Property 3/" Center plate on joint unless x,y p y 4 (Drawings not to scale) offsets are indicated. I Damage or Personal Injury IRE= Dimensions are in ft-in-sixteenths. 11%1,, Apply plates to both sides of truss 1 23 1. Additional stability bracing for truss system,e.g. and fully embed teeth. diagonal or X-bracing,is always required. See BCSI. TOP CHORDS O1 „ 2. Truss bracing must be designed by an engineer.For '/16 wide truss spacing,individual lateral braces themselves may require bracing,or alternative Tor I IMIUMF O IL\111111A111 p bracing should be considered. ._� O A I ,g 3. Never exceed the design loading shown and never stack materials on inadequately braced trusses. O 4. Provide copies of this truss design to the building For 4 x 2 orientation,locate �' designer,erection supervisor,property owner and plates 0-'aa' from outside il 7-8 BOTTOM CHORDS all other interested parties. edge of truss. 8 7 6 5 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each This symbol indicates the JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE joint and embed fully.Knots and wane at joint required direction of slots in AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO locations are regulated by ANSI/TPI 1. connector plates. THE LEFT. 7. Design assumes trusses will be suitably protected from CHORDS AND WEBS ARE IDENTIFIED BY END JOINT the environment in accord with ANSI/TPI 1. *Plate location details available in Muck 20/20 NUMBERS/LETTERS. software or upon request. 8. Unless otherwise noted,moisture content of lumber shall not exceed 19%at time of fabrication. PLATE SIZE PRODUCT CODE APPROVALS 9. Unless expressly noted,this design is not applicable for ICC ES Reports: use with fire retardant,preservative treated,or green lumber. The first dimension is the plate 10.Camber is a non-structural consideration and is the 4 x 4 width measured perpendicular ESR-1311,ESR 1352,ESR 1988 responsibility of truss fabricator.General practice is to to slots.Second dimension is ER 3907,ESR-2362,ESR 1397,ESR 3282 camber for dead load deflection. the length parallel to slots. 11.Plate type,size,orientation and location dimensions indicated are minimum plating requirements. LATERAL BRACING LOCATION 12.Lumber used shall be of the species and size,and in all respects,equal to or better than that �! PPIndicated by symbol shown and/or Trusses are designed for wind loads in the plane of the specified. by text in the bracing section of the truss unless otherwise shown. 13.Top chords must be sheathed or purlins provided at output. Use T or I bracing spacing indicated on design. if indicated. Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs relyon lumber values 14.Bottom chords require lateral bracing at 10 ft.spacing, g or less,if no ceiling is installed,unless otherwise noted. BEARING established by others. t../..• 15.Connections not shown are the responsibility of others. I Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint 16.Do not cut or alter truss member or plate without prior ©2012 MiTek®All Rights Reserved approval of an engineer. 11111111111111 ® number where bearings occur. 17.Install and load vertically unless indicated otherwise. Min size shown is for crushing only. 11110 18.Use of green or treated lumber may pose unacceptable environmental,health or performance risks.Consult with project engineer before use. Industry Standards: ANSI/TPI1: National Design Specification for Metal 19.Review all portions of this design(frontback,words Plate Connected Wood Truss Construction. and pictures)before use.Reviewing pictures alone DSB-89: Design Standard for Bracing. is not sufficient. BCSI: Building Component Safety Information, MiTek6 20.Design assumes manufacture in accordance with Guide to Good Practice for Handling, ANSI/TPI 1 Quality Criteria. Installing&Bracing of Metal Plate Connected Wood Trusses. MiTek Engineering Reference Sheet:MII-7473 rev. 10/03/2015