Loading...
Report terFIRE SYSTEM RESIDENTIAL • COMMERCIAL • INDUSTRIAL EXCEEDING YOUR EXPECTATIONS 24/7! APPMAWR YalEYFRE& ROVED CONDITIONALLY APPROVED p APPROVAL OF PLANS 18 NOT AN APPROVAL OF OMISSIONS OR OVERSEW& SEE ATTACHED R. 0 rI 1NER %/t-1.17 TE PreliminaryOFFICE COPY08/28/2017 10:13:32 AM Express Fire Systems, Inc. 670 S.28th St. Your Street Address 2 Washougal,WA 98671 360-953-8432 Job Name . Drawing Location : Remote Area : Contract Data File : HOSTV-Tigard Calc.WXF Computer Programs p og by Hydratec Inc. Revision: 50.52.1 Water Supply Curve C Express Fire Systems, Inc. Page 1 Date City Water Supply: Demand: Cl -Static Pressure : 85 D1 -Elevation : 18.623 C2-Residual Pressure: 71 D2-System Flow :141.547 C2-Residual Flow : 4487 D2-System Pressure : 57.224 Hose(Demand) : 100 D3- System Demand :241.547 Safety Margin : 27.713 150 140 130 ' p 120 R 110 E 100 S 90 Cl — S 80 A C2 U 70 € 5 Psi Under R 60 $ [a2 E50D. 40 30 20 D1 10 500 1000 1500 2000 2500 FLOW (N 01 .85) 3500 4000 4500 Computer Programs by Hydratec Inc. Revision: 50.52.1 Fittings Used Summary Express Fire Systems, Inc. Page 2 Date Fitting Legend Abbrev. Name 1/2 3/4 1 11/4 11 2 21/2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 13 90'Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 Fsp Flow Switch Potter VSR Fitting generates a Fixed Loss Based on Flow L NFPA 13 Long Turn Elbow 0.5 1 2 2 2 3 4 5 5 6 8 9 13 16 18 24 27 30 34 40 T NFPA 13 90'Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zcd Colt C300 Horz Butt Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with*. The fittings marked with a*show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a*will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Revision: 50.52.1 Flow Summary - NFPA 2007 Express Fire Systems, Inc. Page 3 Date SUPPLY ANALYSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure CWM 85.0 71 4487.0 84.937 241.55 57.224 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes 1 40.0 5.6 8.68 16.5 2 40.0 5.6 9.52 17.27 M1 40.0 13.69 M2 40.0 14.26 M3 40.0 19.6 TOSP 40.0 23.25 BOSP 8.0 39.22 M4 8.0 43.24 TOR 8.0 44.58 BOR 5.0 48.93 ! BORA 1.0 54.95 UG -3.0 56.75 CWM -3.0 57.22 100.0 3 40.0 5.6 10.01 17.72 4 40.0 5.6 10.96 18.54 5 40.0 5.6 9.06 16.85 6 40.0 5.6 9.92 17.64 7 40.0 5.6 10.44 18.09 8 40.0 5.6 11.43 18.93 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen-Williams - 2007 Express Fire Systems, Inc. Page 4 Date Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftng's Pe Notes Node2 Elev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf 1 40 5.60 16.50 1 0.0 11.375 120 8.681 to 0.0 0.0 0.0 2 40 16.5 1.097 0.0 11.375 0.0733 0.834 Vel = 5.60 2 40 5.60 17.27 1 T 6.217 8.917 120 9.515 to 0.0 6.217 0.0 M1 40 33.77 1.097 0.0 15.134 0.2759 4.176 Vel = 11.46 M1 40 36.26 2 0.0 14.500 120 13.691 to 0.0 0.0 0.0 M2 40 70.03 2.157 0.0 14.500 0.0395 0.573 Vel = 6.15 M2 40 71.52 2 T 12.307 24.417 120 14.264 to 0.0 12.307 0.0 M3 40 141.55 2.157 0.0 36.724 0.1452 5.332 Vel = 12.43 M3 40 0.0 2 E 6.153 19.042 120 19.596 to 0.0 6.153 0.0 TOSP 40 141.55 2.157 0.0 25.195 0.1452 3.658 Vel = 12.43 TOSP 40 0.0 3 5B 67.198 32.000 120 23.254 to E 9.408 76.606 13.859 BOSP 8 141.55 3.26 0.0 108.606 0.0194 2.111 Vel = 5.44 BOSP 8 0.0 3 T 20.159 186.542 120 39.224 to 0.0 20.159 0.0 M4 8 141.55 3.26 0.0 206.701 0.0194 4.016 Vel = 5.44 M4 8 0.0 3 T 20.159 48.583 120 43.240 to 0.0 20.159 0.0 TOR 8 141.55 3.26 0.0 68.742 0.0194 1.335 Vel = 5.44 TOR 8 0.0 3 Fsp 0.0 3.000 120 44.575 to 0.0 0.0 4.299 " * Fixed Loss=3 BOR 5 141.55 3.26 0.0 3.000 0.0197 0.059 Vel = 5.44 BOR 5 0.0 3 Zcd 0.0 4.000 120 48.933 to 0.0 0.0 5.942 * * Fixed Loss=4.21 BORA 1 141.55 3.26 0.0 4.000 0.0195 0.078 Vel = 5.44 BORA 1 0.0 4 L 8.72 4.000 140 54.953 to 0.0 8.720 1.732 UG -3 141.55 4.1 0.0 12.720 0.0048 0.061 Vel = 3.44 UG -3 0.0 4 0.0 100.000 140 56.746 to 0.0 0.0 0.0 CWM -3 141.55 4.1 0.0 100.000 0.0048 0.478 Vel= 3.44 100.00 Qa= 100.00 CWM 241.55 57.224 K Factor= 31.93 3 40 5.60 17.72 1 0.0 11.375 120 10.010 to 0.0 0.0 0.0 4 40 17.72 1.097 0.0 11.375 0.0837 0.952 Vel = 6.02 4 40 5.60 18.54 1 T 6.217 2.458 120 10.962 to 0.0 6.217 0.0 M1 40 36.26 1.097 0.0 8.675 0.3146 2.729 Vel = 12.31 0.0 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen-Williams Express Fire Systems, Inc. Page 5 Date Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftng's Pe ******* Notes Node2 Elev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf M1 36.26 13.691 K Factor= 9.80 5 40 5.60 16.85 1 0.0 11.375 120 9.055 to 0.0 0.0 0.0 6 40 16.85 1.097 0.0 11.375 0.0763 0.868 Vel = 5.72 6 40 5.60 17.64 1 T 6.217 8.917 120 9.923 to 0.0 6.217 0.0 M2 40 34.49 1.097 0.0 15.134 0.2868 4.341 Vel= 11.71 0.0 M2 34.49 14.264 K Factor= 9.13 7 40 5.60 18.09 1 0.0 11.375 120 10.438 to 0.0 0.0 0.0 8 40 18.09 1.097 0.0 11.375 0.0869 0.989 Vel= 6.14 8 40 5.60 18.93 1 T 6.217 2.458 120 11.427 to 0.0 6.217 0.0 M2 40 37.02 1.097 0.0 8.675 0.3270 2.837 Vel = 12.57 0.0 M2 37.02 14.264 K Factor= 9.80 Computer Programs by Hydratec Inc. Revision: 50.52.1