Loading...
PFI2018-00136 CITY OF TIGARD PUBLIC FACILITIES IMPROVEMENT PERMIT COMMUNITY DEVELOPMENT Permit#: PF12018-00136 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421 Date Issued: 06/14/2018 Parcel: SEG2395 Jurisdiction: Tigard Site address: Subdivision: Lot: Project: PGE Project Description: SEG2395/2390. Replace underground cable. Owner: FEES Description Date Amount PFI Permit Fee 06/14/2018 $300.00 PHONE: Contractor: PHONE: FAX: Applicant: TOM COX 10800 SW AVERY STREET TUALATIN, OR 97062 PHONE: 503-736-5419 Total $300.00 Please sign below to indicate acceptance of conditions and return a copy with the proposed work schedule along with names and contact information of responsible parties before beginning work. Permittee/Applicant r�� A ��L"�� r n, ! Signature: J A `O�J Issued By: C6_yzz� Special Conditions(See Attached) Note:THIS PERMIT DOES NOT COVER WORK ON PRIVATE PROPERTY Conditions for PIs12018-00136 Type: Condition Name: Status: Severity: PFI_Utilities 01 -WORK SITE REQUIREMENTS Applied Notice Applicant must comply with all applicable provisions of federal and state law,the Tigard Municipal Code, and the terms of any agreement with the City of Tigard regarding work to be done pursuant to this permit. PFI_Utilities 02-WORK SITE AREA Applied Notice The work area and approach roads shall be maintained in a clean condition,free from obstructions and hazards. The spreading of mud or debris or storage of materials or equipment of any kind upon any public roadway is strictly prohibited and violation shall be cause for immediate cancellation of the permit. The City may at any time order immediate clean-up and suspension of work to accomplish clean-up. PFI_Utilities 03-WORK SITE EROSION CONTROL Applied Notice Prior to starting work, effective and approved erosion control devices must be installed and maintained meeting the Clean Water Services and DEQ requirements. The City may at any time order corrective action and suspension of work to accomplish effective erosion control. PFI_Utilities 04-WORK SITE REPAIRS Applied Notice Disturbed landscaped areas shall be restored or replaced. Existing signs, pavement markings, mailboxes, etc. shall be reinstalled or replaced,with like kind of material. Obtain City approval of restoration work. PFI_Utilities 05-TRAFFIC CONTROL SPECIFICATIONS Applied Notice Applicant shall provide traffic control according to the current edition of the"Manual on Uniform Traffic Control Devices [MUTCD]for Streets and Highways", U.S. Dept. of Transportation, FHWA, current edition,American Traffic Safety Services Association [ATSSA], and Oregon Temporary Traffic Control Handbook[OTTCH]. PFI_Utilities 06-TRAFFIC CONTROL PLAN Applied Notice Submit a job specific traffic control plan. A copy of the approved traffic control plan shall be readily available at the work area.Traffic control devices,flag persons,etc., shall be in place prior to initiation of construction work and shall be effectively maintained. PFI_Utilities 07-TRAFFIC CONTROL ROAD CLOSURE Applied Notice Public roadway shall not be closed to traffic, at any time,without obtaining written approval from the City Engineer. The applicant is responsible to provide 48 hour advance notice of traffic flow disruptions to affected businesses, residents and area wide Emergency Services: 503-629-0111 (Tigard Police Dept., Tualatin Fire& Rescue)and to 503-962-8140(Tri-Met) and 503-431-2345(Tigard School District)and other service providers impacted by such closure. PFI_Utilities 08-TRAFFIC CONTROL PROPERTY ACCESS Applied Notice Access to existing properties shall be maintained at all times, including normal delivery service and mail service. Obtain City approval of any access closures. PFI_Utilities 09-TRAFFIC CONTROL WORK HOURS Applied Notice Work is permitted in daylight between the hours of 7:00 a.m.to 7:00 p.m. Mon-Fri unless otherwise authorized by the City. PFI_Utilities 10-TRAFFIC CONTROL LIMITED WORK HOURS Applied Notice Hours of construction work on collector and arterial roads will be limited to 9:00 a.m.to 3:00 p.m. unless authorized by the City Engineer. Work will not be permitted on collector and arterial roads between 3:00 p.m.to 9:00 a.m. unless authorized by the City Engineer. PFI_Utilities 11 -TRAFFIC CONTROL MODIFICATION Applied Notice The City reserves the right to add to or modify traffic control requirements as necessary to effectively control traffic and to assure public safety. PFI_Utilities 12-UTILITY NOTIFICATION Applied Notice Oregon law requires following the rules adopted by the Oregon Utility Notification Center. Said rules are set forth in OAR 952-001-0100 through OAR 952-001-0080. Copies of said rules may be obtained from the Center by calling 503-246-1987. If you have any question about the rules, contact the Center. NOTE: Damage to utilities shall be corrected at the permit holder's expense. PFI_Utilities 13-UTILITY LOCATION CONFLICT Applied Notice Applicant must verify all existing utilities for both vertical elevation and horizontal location prior to start of work(pothole before digging if necessary). Should conflicts arise and redesign or relocation of facilities be necessary, it shall be done at the applicant's expense. Changes must be approved by the City in advance of work.Applicant shall coordinate the work with affected utility agencies. PFI_Utilities 14-TEMPORARY PATCH Applied Notice A temporary hard-surface patch shall be placed on trenches within roadways at the end of each work shift. Obtain advance approval of patching method. No trench shall be left at any time in an un-safe condition. Applicant is responsible for and is liable for hazards or damage resulting from the prosecution of the work. PFI_Utilities 15-REPAIR OF EXISTING FACILITIES Applied Notice Work under this permit shall include repair of existing facilities (roads, ditches, etc.)as may be necessary, as determined by the Inspector,to overcome deterioration or damage which occurred in conjunction with the work authorized by the permit. Corrective work shall be done at the applicant's expense. PFI_Utilities 16-PRECONSTRUCTION MEETING Applied Notice Before initiating any construction activity,the applicant shall coordinate with the City's inspector, <Insert Name>at<Insert Phone#>, to establish a preconstruction meeting. PFI_Utilities 17-NOTICE TO COMMENCE WORK Applied Notice The applicant shall notify the City's Inspector twenty-four(24) hours prior to commencing work, prior to any staged inspection, and after completing work covered by the permit. Contact Ken Fisher at 503 816 6146 or Kenny@tigard-or.gov PFI_Utilities 18-PERMIT/PLAN ON SITE Applied Notice A copy of the permit including a Certificate of Insurance, and all attachments, and a copy of the approved construction plan and all amendments shall be readily available at the work area. All work shall conform to the permit terms, conditions and provisions and to the City approved permit plans, and approved plan amendments and to the City's standards and specifications and to these General Conditions. Changes to any of these must be approved by the City, in advance of work performance. PFI_Utilities 19-MONUMENT PROTECTION Applied Notice Existing monuments, property corners, and survey markers shall be protected. Replacement shall be at the permit holder's expense. PFI_Utilities 20-EMERGENCY CONTACTS Applied Notice Provide to the City inspector, in writing, the names and 24 hour emergency telephone number of two(2) persons who have authority to resolve problems,take corrective action and, in general,will be responsible in case of any emergency. The applicant shall notify the City Inspector, in writing, of any/all assignment changes. PFI_Utilities 21 -OTHER Applied Notice RECOVED 2 (City of Tigard JUN 0 201 PUBLIC WORKS — ENGINEERING ITV OF TIGARD ° VffhffEERING T Public 1�ac� Imrovement (PFTT r w . TYPE OF WORK DESCRIPTION OF WORK(in the right-of-way) TYPE 1—Franchise Utility Work Check one: Y Utilities ❑Sidewalk/driveway approach ❑ Streetimprovements performed by NWN, PGE Detailed description: Replace underground cable and/or utility agency. ❑ TYPE 2—Sidewalk./Driveway/Sewer PGE Job M2432127 Work performed for the purpose of- - Sidewalk installation or repair. ° Driveway approach installation 9603 SW Durham Road Property address/location(s): and/or repair aG 2 S 23i 0 Tigard, OR 97224 ° Sanitary sewer lateral installation and/or main line tap Portland General Electric Submitted b El TYPE 3—Full scale Development Applicant: y Amy Swean y] Work performed with Land use Address: 10800 SW Avery Street approval which includes any of City/state: Tualatin, OR Zip. 97062 the following: Phone: 503-612-2935 Email: preregcoord@pgn.com ° Subdivisions or Partitions Contact name: Tom Cox Phone: 503-736-5419 ° Street widening ° Mainline installation for Sanitary Contractor: TBD sewer, Storm sewer, Tigard water and/or Tigard Water Service Area CCB#: Expiration: Address: SUBMIT COMPLETED APPLICATION TO: City/state: Zip: City of Tigard Planning/Engineering Phone: Email: 13125 SW Hall Blvd. Contact name: Phone: Tigard,OR 97223 Applications for"minor work in right-of-way" Engineer: NSA only may be emailed to: rowpermits o tigard-or.gov Address: nm1° mw un emu City/state: Zip: Phone: Email: Case No.: :FFt 2_0 8'.00l Contact name: Application submittal fee(.007%o of Engineer's Estimate) $ jL° Estimated value of work is required(if over$5,000):$ 11,519.32 Additional fees: $ (within the public right-of-way) Application accepted: Is work related to a LAND-USE DECISION? Yes No By: Date: Application reviewed: If so, please specify (MLP,SDR,SUB, etc.) case #: By: Date: Q -4 Is work related to a BUILDING PERMIT? ❑ Yes Cid'No Applicant notified: If so,please specify(BUILDING PERMIT)case#: By: �-' Date: A I:\ENG\PermitApplications\pfi—application Rev.10/16/2017 !� ✓ u Q ��.'��5�Aft- ��\ .j. �"!�6 i C City ofTigard 13125 SW Hall Blvd. Tigard,Oregon 97223 www.tigard-or.gov 503-718-2421 o Page 1 of4 APPLICANTS NOTE: Person specified as "Applicant" shall be designated"Permittee"and shall provide financial assurance for work,if required by the city pursuant to TMC 15.041.140. * With the exception of a utility operating pursuant to a valid franchise with the City of Tigard,when the owner and the applicant are different people,the applicant must be the purchaser of record or a lessee in possession with written authorization from the owner or an agent of the owner. The owner(s) must sign this application in the space provided or submit a written authorization with this application. Franchised Utilities are not required to obtain the owners signature on the application BY SIGNING BELOW,THE APPLICANT(S) SHALL CERTIFY TIFY THAJC: • The above reduest does not violate any recorded deed restrictions that may be attached to or imposed upon the subject proj2em. o If the application is granted,the applicant will exercise the rights granted in accordance with the terms and subject to all the conditions and limitations of the approval. o All of the above statements and the statements in any plot plan,attachments,and exhibits transmitted herewith,are true;and the applicants so acknowledge that any permit issued,based on this application,may be revoked if it is found that any such statements are false. o The applicant has read the entire contents of the application,including the policies and criteria,and understands the requirements for approving or denying the application. ®/�nh ® Digitally signed by Vinh D �!� Nguyen,PE (! ° n u ye n, P E -07'00'018.06.05 12:02:15 Applicant/Authorized Agent's signature Print name Date SIGNATURES of each owner of the subject property, if required. Owner's signature Print name Date Owner's signature Print name Date Owner's signature Print name Date PUBLIC FACILITY IMPROVEMENT PERMIT City ot-Tigard 13125 SW Hall Blvd. o Tigard,Oregon 97223 o w�vw tigard-or.gov 503-718-2421 Page 2 of4 1--')EVELOPMENI'ENGINEERING]FEES FOR Public Facility Improvement(PFI)Permit: DETAILED SUBMITTAL REQUIREMENTS APPLICA`T'ION FEE Part 1: Required submittal fee$300.00 (minimum) FRANCHISE UTILITY AND SIDEWALK/ DRIVEWAY AND UTILI'T'Y PERMIT FEE CONNECTIONS,ETC. Part 2: All non-water system improvements (work in the right of way) Engineer's estimate X 5% (less$300.00 minimum submittal fee) Sketch Engineer's estimate X 2%Plan Review (including information below) ❑ Dimensions WATER SYSTEM FEE ❑ Street Name Part 3: All public water system improvements El Site Address Engineer's estimate X 12% FULL SCALE DEVELOPMENT PFI Permit Fee Exemptions: (Subdivisions/Partitions and Street Improvements) There will be no permit fee charged,or assurance required for the following types of work: Design Plans • Sidewalk repair(less than 20 lineal feet) (6 sets,24x36 or 2204) • Relocate or replace mailbox ❑ Cover—Site,Vicinity,Abbreviation,Legend • Ditch cleaning that does not involve regrading. ❑ General Notes(City,Water;Sewer,etc.) • Weep hole repair ❑ Street(Plan,Profile) • Curb repair or replacement(less than 20 lineal feet) FT Water,Storm and Sanitary=(Plan Profile) • Lawn sprinkler system installation or repair ❑ Water Quality Facilities • Street tree pruning or planting ❑ Grading • Planter strip landscape maintenance ❑ Landscaping/Tree Plan • Test wells ❑ Composite Utility Plan(Electrical,.Phone,Gas, Storm;'Sanitary;Water,Signage,Street Lights;etc) ❑ Details: Note: A cash/bond assurance maybe ❑ Traffic Sight Distance required per TMC 15.04.140. ❑ Signing and Striping (customer deposit) ❑ Street Light Plan and Photometric ❑ Engineers seal/signature ❑ Sheet label(project,land use name,revision and plan log block,dates and sheet numbers.) Additional Submittals (per Land Use conditions) ❑ Traffic Report ❑ Storm water Drainage Calculations ❑ Geotechnical Report ❑ Preliminary Access Report(Sight Distance) ❑ Proposed Plat ❑ Pathway Design(if applicable) El Water Department Approval ❑ Engineer's Construction Estimate PUBLIC FACILITY IMPROVEMENT PERMIT City ofTigard 13125 SW Hall Blvd. • Tigard,Oregon 97223 • wwwtigard-or.gov • 503-718-2421 Page 3 of4 SAMPLE SKETCH: I - E.d a of PtVerteni: a dt p I'YI Ditch. w Mom a 1 mi*as&a�a dens a r r� Rldn Drain II . . T 71,UP 05 &W 5 111 I all Y t , 1 -pas � I E%is,tIn� ?f 51 1 KU 1. s (61 co 41 ■ (61 t .I c-4 ■ �® I Y 1 Y P Cdwe1' o'le B 951 I�' I s Fire Hydrant(FH) � I � Scale,. 'I' 30` � I � 1I MINIMUM SKETCH REQUIREMENTS(Put"N/A"if Not Applicable): North arrow Property lines &dimension Slope of property Street &street name(s) Existing building, structures Utility& street light poles Proposed work Existing curb or edge Trees Existing S/W or of pavement Existing utility locations D/W apron (sewer,water,storm) PUBLIC FACILITY IMPROVEMENT PERMIT City ofTigard ■ 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.tigard-or.gov ■ 503-718-2421 • Page 4 of4 9610 ,' 9600 9590, q 954 LEGEND WL 2 VT-14924: 2�! REMOVEIABANDON FACILITIES l INSTALL FACILITIES Install: y INSTALL ADDITIONAL FACILITIES/MODIFY FACILITIES ELBOW KIT-JKTD CABLE-#2AL- y Remove: Qy G'� ! 1 WORK LOCATIONS ELBOW KIT-JKTD CABLE-#2AL 4570 / P O -------- SURVEY GRID BOUNDARY 0 i sssoO ' CONDUCTORS 9540 •� 4 INSTALL AO#2 AL EPR JKT-D PRIMARY _ _ O�v - ,-' ——— ——- 2-CONDUIT&INSTALLED BYPGE *PROVIDED 15945 1 Gj� 9530 'PROVIDED&INSTALLED BYPGEAPPROVED CONTRACTOR 2 _ ABANDON PRIMARY CABLE s 'GROUND ABANDONED CABLE PER LC22035-7 --___---- VT-14924 � I �� � A-50 24659 I 9520 EQUIPMENT j O� Q SMALL FAULT INDICATOR(S)VAR TRIP 200 A 15955 I I # �1 I' C2 1-11® Q� R 15965 M 9510 21 C21-11C —15970 2ZJ I IN W W WL 1 VT-17: I 15975 r Install: ELBOW KIT-JKTD CABLE-#2AL i a r Remove: i 15985 a I ELBOW KIT-JKTD CABLE-#2AL -— 1 15980 15995 30204! 15990 t 25'-41 — ' L 1979 AL . A 46 25'-4 1 - ----VT-17 -1990 ----- ---- -� ABC•2/0•AL AABBCC•750 AL ..-——r r r r-r----_rr_r_.NAL­ ' AABBCC•750 AL m SWOURHAIMRD L I a C2 1-14B i r I 9627 0 25 SW FERN HOLLOW C714A 16060 1, 00 F et — r- ---- X450 Y N 1 n I{e I N PD I/1G 1�lll Y tl Q B 80 1611BPD 73E5 VT 7361- f 6 f ' �w a fi '� - VT-67.•. ' t b010766 C 60419344VT 7334 p�-. yr 6e- 5�w .SU @9MEC�Fi L DR 71 c e I e m n r 1 Q - VT-69 7362 QBPL 7521 Cr�'�d f f ASD 17888VT 7369 y A 700 1 � 15 760, VT-675.1 B 60.2 Qin' t 764898 "PD 7678 `,a A2844115 D�21 f � .IASO1896 ( P ...Y { > 50 2086$, PD-7674 ,31 A A,a;��--3014-- T s I p y Vi 7363 4 _ -m A 50 20882•,, .: - 1 B =6 C2 1 11D �t J. I zs e369e + Po 7sos bo 200$$ »i Open m 7 ASO 98484VT 14023-' - PD 7675: - .. �,;• - A'504060 '1 1690 f - 1S 86018 PO-7677 A A 2S 4S6 , 7394 A SO 68888 Q 6018714 S a }PL-6262 4r��1492�rry r� VT 14923 J PD 773. 60 248P 76 2169 - CBO 20820, b753 A°60 20837 a o j r r " 60 20898P0 7733' `A'8014716 C - - s ABC 76 3421OP,0 736 •'' 3P 1 PL-19 ?L f589 A7 /i1REI�1l - 6 ABC 434/;aC LI.: 5030'184 PDQ;, - on_AR(: u, 53015 - 0 112.5'225 450-Feet-AS S ___ __ _-ABC Bc ABC A D Aec_ All - CZ 1-,146, ` `:JPL`21 VTJJPD_A rt• I - 'i 6097811 f .C2 1--P-E N !, PGE CONSTRUCTION DRANRNG AS-BUILT VERIFICATION&NESC VIOLATIONS CORRECTED mo aocumemec teiy,evreeeeB FIELD conzo-„cnoe Foreman: Date: THINK General Foreman: Date: SAFETY Si nature onl required for held construction changes.) SDPANENG REVIEW. ASBUILT BY DESIGNER- IRST DATE: SCALE: A OUNT.' AWO: JOB NO. NY DEVIATION FROM THIS DESIGN MUST 12/12/2017 1 in=50 ft 1070001 0000014628 M2432127 �JBE APPROVED BY THE PGE PROJECT MANAGER nr�E REPLACE B/O UG PRIMARY CALL 811 BEFORE YOU DIG CIRCUIT SIZE ATTENTION: KING CITY-SUMMERFIELD 17 x 11 OREGON LAW REQUIRES YOU TO FOLLOW RULES ADOPTED ,. PGE LOCATION BY THE OREGON UTILITY NOTIFICATION CENTER. r ` 9603 SW DURHAM RD,TIGARD,OR,97224 THOSE RULES ARE SET FORTH IN OAR 952-001-0010 1 DESCRIPTION THROUGH 952-001-0090 YOU MAY OBTAIN COPIES OF REPLACE B/O UG PRIMARY BETWEEN VT-17&VT-14924 SHEET THE RULES BY CALLING THE OREGON UTILITY COUNTY I SECTIONS WORK WITH NOTIFICATION CENTER ADMINISTRATION @(502-232-1987) WASHINGTON C2111C,C2114B 1 1 OF 1 TO REQUEST UTILITY LOCATES CALL THE OREGON KnOWwh81$below —SON—E DESIGNBY PHONE DRAWNBY UTILITY NOTIFICATION CENTER,811 AT LEAST CBllbdareymdig UNE CREW CENTER TOM COX 503-867-04141 HEIDI BOOMER 2 BUSINESS DAYS PRIOR 70 EXCAVATION vies swaoEC"R 97 7o ©PORTLAND GENERAL ELECTRIC CO.-ALL RIGHTS RESERVED www.invarionxom ^.` RC-t" :. +;a -r'.rkeu+e �n �n�o�aC��finu '. ���Le�'fur{nLan� y r=y} ■yjy■y�y�■�/q Diagram 430 shows work in the travel lane(s)next to a continuous two-way left turn lane with one direction of traffic diverted into the continuous two-way left turn lane. 1. Use truck-mounted flashing warning lights on work and protection vehicles. See Section 4.3—Lights and Lighted Signs for exceptions. 2. For added visibility, a truck-mounted arrow board or PGMS in caution mode may be used. 3. When two or more travel lanes are reduced to a single lane before the diversion, each lane shall be closed separately. Layout traffic control according to ODOT Standard Drawing TM 852 for 5-lane sections. 4.A shifting taper(L12)may be added in the diverted traffic direction across the continuous two-way left turn lane (as shown).This option is recommended when the speed is 45 mph or greater. Sign Spacing and Buffer Lengths(feet) C }A ERRATA: 20 - 50 25 100 100 100 75 Supplement Table 30 100 35 350 350 350 125 updated:February 12, 40 150 2016 45 180 By:ODOT Traffic-Raodway 50 500 500 500 210 section 55 250 Signs Spacing and Buffer Lengths (feet)Supplement Uffe I.4u�'.' gaM��.9.tw9 60 285 65 700 700 700 325 70 365 www,i nvado n.com t"..t'�"i P.F'' ". s "' Vlilx s-� i�oke sr -wrihid as C,on�inutil) Left' �uirn La�iin� $ ;� °a Dia�r,� x r;:f x ,.xt v »:.. ROAD WORK HEAD B Cyt CENTER LANE CLOSED HEAD A if 101 U2 0 0 0 Buffer Protection Vehicle wrrMA(both Optional) See Chapter 4 C A Buffer 0 0 U2 0 ( o o r U2 o a II0 t B <S> ROAD WORK HEAD