Loading...
PFI2018-00138 CITY OF TIGARD PUBLIC FACILITIES IMPROVEMENT PERMIT COMMUNITY DEVELOPMENT Permit#: PF12018-00138 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421 Date Issued: 06/14/2018 Parcel: SEG714 Jurisdiction: Tigard Site address: Subdivision: Lot: Project: PGE Job M2320746 Project Description: SEG714 and SEG715, associated with 13387 SW Laurmont Ct. Install new street light circuit. PGE Job M2320746 Owner: FEES Description Date Amount PFI Permit Fee 06/14/2018 $300.00 PHONE: Contractor: PHONE: FAX: Applicant: JOSE GRAJEDA 10800 SW AVERY STREET TUALATIN, OR 97062 PHONE: 503-672-5602 Total $300.00 Please sign below to indicate acceptance of conditions and return a copy with the proposed work schedule along with names and contact information of responsible parties before beginning work. Permittee/Applicant Signature: 1, 1��e A A���Ir��T Q ® / �V Issued By: 1,44evi L�� Special Conditions(See Attached) Note:THIS PERMIT DOES NOT COVER WORK ON PRIVATE PROPERTY Conditions for PF12018-00138 Type: Condition Name: Status: Severity: PFI_Utilities 01 -WORK SITE REQUIREMENTS Applied Notice Applicant must comply with all applicable provisions of federal and state law,the Tigard Municipal Code, and the terms of any agreement with the City of Tigard regarding work to be done pursuant to this permit. PFI_Utilities 02-WORK SITE AREA Applied Notice The work area and approach roads shall be maintained in a clean condition, free from obstructions and hazards. The spreading of mud or debris or storage of materials or equipment of any kind upon any public roadway is strictly prohibited and violation shall be cause for immediate cancellation of the permit. The City may at any time order immediate clean-up and suspension of work to accomplish clean-up. PFI_Utilities 03-WORK SITE EROSION CONTROL Applied Notice Prior to starting work, effective and approved erosion control devices must be installed and maintained meeting the Clean Water Services and DEQ requirements. The City may at any time order corrective action and suspension of work to accomplish effective erosion control. PFI_Utilities 04-WORK SITE REPAIRS Applied Notice Disturbed landscaped areas shall be restored or replaced. Existing signs, pavement markings, mailboxes, etc. shall be reinstalled or replaced,with like kind of material. Obtain City approval of restoration work. PFI_Utilities 05-TRAFFIC CONTROL SPECIFICATIONS Applied Notice Applicant shall provide traffic control according to the current edition of the"Manual on Uniform Traffic Control Devices [MUTCD]for Streets and Highways", U.S. Dept. of Transportation, FHWA, current edition,American Traffic Safety Services Association [ATSSA], and Oregon Temporary Traffic Control Handbook[OTTCH]. PFI_Utilities 06-TRAFFIC CONTROL PLAN Applied Notice Submit a job specific traffic control plan. A copy of the approved traffic control plan shall be readily available at the work area.Traffic control devices,flag persons,etc., shall be in place prior to initiation of construction work and shall be effectively maintained. PFI_Utilities 07-TRAFFIC CONTROL ROAD CLOSURE Applied Notice Public roadway shall not be closed to traffic, at any time, without obtaining written approval from the City Engineer. The applicant is responsible to provide 48 hour advance notice of traffic flow disruptions to affected businesses, residents and area wide Emergency Services: 503-629-0111 (Tigard Police Dept.,Tualatin Fire&Rescue) and to 503-962-8140(Tri-Met) and 503-431-2345(Tigard School District)and other service providers impacted by such closure. PFI_Utilities 08-TRAFFIC CONTROL PROPERTY ACCESS Applied Notice Access to existing properties shall be maintained at all times, including normal delivery service and mail service. Obtain City approval of any access closures. PFI_Utilities 09-TRAFFIC CONTROL WORK HOURS Applied Notice Work is permitted in daylight between the hours of 7:00 a.m.to 7:00 p.m. Mon-Fri unless otherwise authorized by the City. PFI_Utilities 10-TRAFFIC CONTROL LIMITED WORK HOURS Applied Notice Hours of construction work on collector and arterial roads will be limited to 9:00 a.m.to 3:00 p.m. unless authorized by the City Engineer. Work will not be permitted on collector and arterial roads between 3:00 p.m.to 9:00 a.m. unless authorized by the City Engineer. PFI_Utilities 11 -TRAFFIC CONTROL MODIFICATION Applied Notice The City reserves the right to add to or modify traffic control requirements as necessary to effectively control traffic and to assure public safety. PFI_Utilities 12-UTILITY NOTIFICATION Applied Notice Oregon law requires following the rules adopted by the Oregon Utility Notification Center. Said rules are set forth in OAR 952-001-0100 through OAR 952-001-0080. Copies of said rules may be obtained from the Center by calling 503-246-1987. If you have any question about the rules, contact the Center. NOTE: Damage to utilities shall be corrected at the permit holder's expense. PFI_Utilities 13-UTILITY LOCATION CONFLICT Applied Notice Applicant must verify all existing utilities for both vertical elevation and horizontal location prior to start of work(pothole before digging if necessary). Should conflicts arise and redesign or relocation of facilities be necessary, it shall be done at the applicant's expense. Changes must be approved by the City in advance of work.Applicant shall coordinate the work with affected utility agencies. PFI_Utilities 14-TEMPORARY PATCH Applied Notice A temporary hard-surface patch shall be placed on trenches within roadways at the end of each work shift. Obtain advance approval of patching method. No trench shall be left at any time in an un-safe condition. Applicant is responsible for and is liable for hazards or damage resulting from the prosecution of the work. PFI_Utilities 15-REPAIR OF EXISTING FACILITIES Applied Notice Work under this permit shall include repair of existing facilities(roads, ditches, etc.)as may be necessary, as determined by the Inspector,to overcome deterioration or damage which occurred in conjunction with the work authorized by the permit. Corrective work shall be done at the applicant's expense. PFI_Utilities 16- PRECONSTRUC T ION MEETING Applied Notice Before initiating any construction activity,the applicant shall coordinate with the City's inspector, <Insert Name>at<Insert Phone#>, to establish a preconstruction meeting. PFI_Utilities 17- NOTICE TO COMMENCE WORK Applied Notice The applicant shall notify the City's Inspector twenty-four(24)hours prior to commencing work, prior to any staged inspection, and after completing work covered by the permit. Call Ken Fisher at 503 816 6146 or Kenny@tigard-or.gov PFI_Utilities 18-PERMIT/PLAN ON SITE Applied Notice A copy of the permit including a Certificate of Insurance, and all attachments, and a copy of the approved construction plan and all amendments shall be readily available at the work area. All work shall conform to the permit terms, conditions and provisions and to the City approved permit plans, and approved plan amendments and to the City's standards and specifications and to these General Conditions. Changes to any of these must be approved by the City, in advance of work performance. PFI_Utilities 19-MONUMENT PROTECTION Applied Notice Existing monuments, property corners, and survey markers shall be protected. Replacement shall be at the permit holder's expense. PFI_Utilities 20-EMERGENCY CONTACTS Applied Notice Provide to the City inspector, in writing,the names and 24 hour emergency telephone number of two(2) persons who have authority to resolve problems, take corrective action and, in general,will be responsible in case of any emergency. The applicant shall notify the City Inspector, in writing, of any/all assignment changes. PFI_Utilities 21 -OTHER Applied Notice RECEWED (pity of Tigard JUN ® 7 2018 PUBLIC WORKS — ENGINEERING CITY OF TIGARD Ove e t r1LIVGINEERIiVG u� c Facility (PFI) �� '�, ° ', .::: i`kf.,,n,,,nwc�i,G.adaa\$ 1i iLY�aRiuSt"u.J,e".'Ficw..1t`�.., w.dai�xl'•`�'^`cam.". n.... . a.ulsazzv..;:., i,.. .".'�uiSC ,.�.,3;t`"-.2"uR . ...a ', - ,..,i. .............. ...a.,.:\'� `@',.i"S" tc«�mM., z 'E ®F DESCRIPTION OF WORD(in the right-of-way) Y(TYPE 1—Franchise Utility Work Check one: [V Utilities ❑ Sidewalk/driveway approach ❑ Street improvements performed by NWN, PGE Detailed description: Install new street light circuit and/or utility agency. ❑ TYPE 2—Sidewalk/Driveway/Sewer PGE Job M2320746 Work performed for the purpose of: 33V - Sidewalk installation or repair. i a Driveway approach installation Property address/location(s): 13N7 SW Laurmont Ct and/or repair Tigard, OR 97223 o Sanitary sewer lateral installation and/or main line tap Applicant: Portland General Electric [Submitted by Amy Sweany] ❑ TYPE 3-Full scale Development Work performed with Land use Address: 1 Q500 SW Avery Street approval which includes any of City/state: Tualatin, OR Zip: 97062 the following: Phone: 503-612-2935 Email: preregcoord@pgn.com o Subdivisions or Partitions Contact name: Jose Grajeda Phone: 503-672-5602 ° Street widening Mainline installation for Sanitary Contractor: Portland General Electric sewer, Storm sewer, Tigard water and/or Tigard Water Service Area CCB#: 103663 Expiration: Address: SUBMIT COMPLETED APPLICATION TO: City/state: Zip: City of Tigard 503-464-7777 Planning/Engineering Phone: Email: 13125 SW Hall Blvd. Contact name: Phone: Tigard,OR 97223 Applications for"minor work in right-of-way" only may be emailed to: Engineer: NSA romTermitsktigard-or.gov Address: © ° Q City/state: Zip: 3`9 Phone: Email: Case NoI, =. '' Contact name: Appltcation subini, fee(007% Engineer's Estirnate) i� Estimated value of work is required(if over$5,000):$ TBD upon bid award Additional fees $ (within the public right-of-way) Application accepted ~. Is work related to a LAND-USE DECISION? El Yes �No By. Date If so, please specify (MLP, SDR, SUB, etc.) case #: Application reviewed: By: ,$S ate:. -°` Is work related to a BUILDING PERMIT? ❑ Yes N� NoAppiicanit notified:" If so,please specify(BUILDING PERMIT)case#: By: ;�. Date I:\ENG\PermitApplicatiohs\pfi—application Rev 10/16/2017 i'Y..wnv'w,, m, s x .:...ifc .,� .. .«..U<«nauua.,.wZd City of`I`igard 13125 SW Hall Blvd. Tigard,Oregon 97223 wwwtigard-or.gov 503-718-2421 Page 1 of APPLICANTS NOTE: Person specified as "Applicant" shall be designated"Permittee" and shall provide financial assurance for ,vork,if required by the city pursuant to TMC 15.041.140. * With the exception of a utility operating pursuant to a valid franchise with the City of Tigard,when the owner and the applicant are different people,the applicant rnust be the purchaser of record or a lessee in possession with written authorization from the owner or an agent of the owner. The owner(s) must sign this application in the space provided or submit a written authorization with this application. Franchised Utilities are not required to obtain the owner's signature on the application BY SIGNING BELOW,THE APPLICAN'T'(S) SHALL CERTIFY TFIAT: o The above request does not violate any recorded deed restrictions that may be attached to or unposed upon the subject ro er 7. o If the application is granted,the applicant will exercise the rights granted in accordance with the terms and subject to all the conditions and limitations of the approval. o All of the above statements and the statements in any plot plan,attachments,and exhibits transmitted herewith,are true;and the applicants so acknowledge that any permit issued,based on this application,may be revoked if it is found that any such statements are false. o The applicant has read the entire contents of the application,including the policies and criteria,and understands the requirements for approving or denying the application. Aroun Xaybanha 06/07/2018 Applicant/Authorized Agent's signature Print name Date SIGNA'JCZJJEI.IES of each owner of the subject property, if required. Owner's signature Print name Date Owner's signature Print name Date Owner's signature Print name Date PUBLIC FACILITY IMPROVEMENT PERMIT City of-Tigard 13125 SW Hall Blvd. o Tigard,Oregon 97223 o www.tigard-ongov 503-718-2421 Page 2 of DEVELOPMENT ENGINEERING FEES ® . • Public Facility Improvement(PFI)Permit: 1 1 $ APPLICATION FEE Part 1: Required submittal fee$300.00 (minimum) FRANCHISE UTILITY AND SIDEWALK DRIVEWAY AND UTILITY PERMIT FEE CONNECTINS,ETC Part 2: All non-waters stem improvements 5 (work m the;right of way) Engineer's estimate X 5% (less$300.00 minimum submittal fee) Slfe�tch (including,,inforrnation below} Engineer's estimate X 2%Plan Review ❑.Dimensions WATER SYSTEM FEE ❑ :Street Name° Part 3: All public eater system improvements ❑ Szte Address Engineer's estimate X 12% FUg.L SCALE DEVE>JO-PM]EN'I' PFI Permit Fee Exemptions: '"{Subdivisions/Partitions and StreetImprovements) There will be no permit fee charged,or assurance required for the following types of work: Desrgrr Plans • Sidewalk repair (less than 20 lineal feet) (6 sets,24 c36 or 22x34) • Relocate or replace mailbox ❑ Lover Site;Vicinity,Abbreviation,Legend • Ditch cleaning that does not involve regrading. ❑ Genera]1"N otes (City;�X/ater,Sewer;etc) • Weep hole repair ❑ Street(flan,Profile) • Curb repair or replacement(less than 20 lineal feet) ❑ Water;Storni and.Sanitaty(Plan-Profzle) • Lawn sprinkler system installation or repair ❑'Water,Quality'.I acihties • Street tree pruning or planting ❑ Grading • Planter strip landscape maintenance ❑ _I andscaping/Trc c Plan, • Test wells ❑ ;Composite LTtility'Plari(Electrical,Phone,Gas, Storm,Sanitary,Water,Signage;Street Lights,etc): ❑.:Details Note: A cash/bond assurance maybe ❑ Traffic Sig11t Distance required per TMC 15.04.140. ❑ Signing and Strtpmg (customer deposit) ❑ Street Light Plan and Photomet, ❑ nngirieers.seat/signature ,.; b ... ❑ Sheet label(protect land use name,revision and, Plan kg block,dates and`sheet;numbers} Additional Submittals . . „ (per I and"Use conditions) ` ❑ Traffic Rep"ort ❑ Storm water Drainage Calculations ❑ Geotechnical Report ❑ ;Preliminary Access Report(Sight Distance)' ❑ P Plat ❑ Pathway Design,(if applicable) ❑ Water Depar'trnent Approval ❑ :Engineer's Construe ri Estimate.. :�__:"'...:..-���`-o't��xe.«�...1,,,r?.,- a3.�.:V:,,*.'i. ��..n,.prp8 „_a.<-s..:�::.:<,��; vz, �.•. ...�a:&a��� _...... a.," _ PUBLIC FACILITY IMPROVEMENT PERMIT City ofTigard 13125 SW Hall Blvd. • Tigard,Oregon 97223 0 wwwtigard-or.gov 503-718-2421 Page 3 of SAMPLE SKETCH: SA .: 'Edge,of P aentert. Ditch Streetlight iL R1.3n Drain' f�. oil T—rrWos� -Mu6rrin 64 x a Ail E E �stiri House I; Existing >i Drivewa.y. p' eti G W, r Iryp1 t klii o �• EASti66 Sho'p • I .. �. C ' _.:. xc Power ole .� o � bra p e rty�Li n e+ . 0 d .. B I I Fir6 H drant FH ° S,c a 10 -1`.=30' A'. e. 0 I I i i MINIMUM SKETCH REQUIREMENTS (Put"N/A"if Not Applicable): North arrow Property lines & dimension Slope of property Street & street name(s) Existing building, structures Utility& street light poles Proposed work Existing curb or edge Trees Existing S/W or of pavement Existing utility locations D/W apron (sewer,water,storm) �'�..��3�:?ssa�a'�". •.....�..> ».�,r,.:....... •.'?: 'sa,.,_,�,..,.w,:�:.n:.-t".<�:�'..m.�i.. ."...'"m�•.?�a�� ux%:.:... <,a� ha'^m�c�..�„ :::. ,"`r'"+s.:.., .„..�"ur:,s„�.�' ... ,�•,z.. �,.x...a:.<:"„_.�.:.�,�.�r�<E:�.:;; °'” ,��� :;:m, �...«<a�,�c:. PUBLIC FACILITY IMPROVEMENT PERMIT City ofTigaird • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.tigard-or.gov • 503-718-2421 • Page 4 of V LIGHTING LEGEND (UNLESS OTHERWISE SPECIFIED) INSTALL 1-10 AL-TX ST LT CIRCUIT IN 1-3"SCH40 PVC - B SQ 25620 5 CONDUIT,PROVIDED & INSTALLED BY CONTRACTOR INSTALL 1-#10 CU-TX ST LT CIRCUIT IN 1-1"SCH40 PVC _®____ i CONDUIT,PROVIDED & INSTALLED BY CONTRACTOR ® 1324 Street Light Junction Box Provided by PGE Installed by Contractor 8 5017295 INSTALL 100W HPS T& C LIGHT PD-18278 ON 20'2 PC FIBERGLASS POLE CONNECT 240 VOLTS (BOTTOM PIECE PROVIDED BY PGE,CONTRACTOR TO INSTALL) CONSTRUCTION NOTES: sLcsT 1. CUSTOMER TO PROVIDE ALL TRENCHING,BACKFR-LING,CONDUIT ELBOWS,JUNCTION E BOXES.VAULTS AND PADS.JOINT USE TRENCH WITH GAS TRENCH TO BE 481NCPIES DEEP AND 30 INCHES WIDE,MEASURED FROM FINAL GRADE. 2. A PGE STANDBY CREW IS REQUIRED FOR OPENING ALL ENERGIZED PGE VAULTS B Z JUNCTION BOXES AND EQUIPMENTIFACILITIES INCLUDING CONNECTOON OR INStALLATION I TSO SCHEDULE A CREW.AN?)PULL STRINGS.CALL 6E ORDINATION AT 503-323-6700 - e 3. ALL PGE CONDUCTORS TO BE INSTALLED IN GRAY,SCHEDULE 40,ELECTRICAL 1 a,. GRADE,PVC CONtUiT WRH NYLON PULL STRINGS,(MIN.500 LBS.TEST) . C1 1-33D _ PGE TO DETERMINE THE SSCONDUITS E AND NUMBER OF ITS REQUIRED. ` MAINTAIN 12 NICHES AND 24 HORIZONTAL INCHES CLEARANCE BE 38 EN _ ALL - - THINKR1�31D$TDEOEL APPROVED FIBERGLA4S13 BENDSf TO F RUNS RADIUS. i f 151 FEET OR L OR FOR ANY LENGTH RUN WITH MORE THAN 180 DEGREES + ! 1 ����TY IN BENDS. PVC 40 BENDS ARE ACCEPTABLE FOR RUNS OF 150 FEET OR LESS.THE MAXI TOTAL BENDS IN ANY CONDUIT RUN IS 270 DEGREES. ALL { BENDS MUST BE F, ORY MADE. REFER TO LETTER OF RESPONSIBILITY FOR 15 PL 8067 FIRST! 1 165' FURTIR DETAILS. - 4. FLUSH CONCRETE TO RB/ ALK D TO BE INSTALLED WITH TOP OF BASE ALL FOOTINGS NEE 1 �U ®QCT - - S. CUSTOMER RESPONSIBLE FOR ROAD CROSSINGS. ALL CROSSINGS MUST EXTEND 1 - -- FROM PROPERTY LINE TO PROPERTY LINE. CROSSINGS TO BE 48 INCHES DEEP, I MEASURED FROM FINAL GRADE. I 6. DIRECTIONAL BORING REQUIREMENTS:BLACK HDPE (HIGH DENSITY POLYETHYLENE) DUCT B0 SW d ALIRMOIMr®R OR SCHEDULE 40 PVC WITH A MECHANICAL CONNECTION (CERTA-LOK OR LIKE MECHANICAL CONNECTION PRODUC AS AN ALTERNATIVE TO HDPE DUCT.HDPE SHALL MEET THE pa�7992 REQUIREMENTS O�PGE SPECIFICATION LC20515 AVAILABLE ON REQUEST FROM PGE PROJECT ?i :_ j --- T ST ALL BE BLACK WITH THREE EQUALLY SPACE AE L - INSTALLATION WITH PGE INSPECT PRESENT. t HD PIPE IS REQUIRED AFTER r MANAGE FOR SAFETY EXTRUDE RED STRIPES WHICH IS A SPECIFICATION REQUIREMENT) MANDRE PE QU INS TH OR .I� N� 7. TRANSFORMER PADS ARE TO BE SET SO THAT THE TOP IS 2 INCHES ABOVE j. JUNCTION BOX INSTALLATIONS i �.� FINAL GRADE. CONDUIT IS TO BE INSTALLED IN PAD AS INDICATED IN DETAIL I AND TO EXTEND 1 INCH ABOVE THE PAD. FOR STREET LIGHTING f._ _..__ , ' j 2 PIECE FIBERGLASS (COMPOSITE) POLE CONTACT PGE FOR APPROVED MANUFACTURERS � F � � 8. ALL PGE TRANSFORII+�RS TO BE INSTALLED 8 FEET (MINA FROM ANY COMBUSTIBLE BUDDING,WALL OVERHANG AND 4 FEET (MIN FROM ANY FIRE HYDRANT. FINAL GRADE IF HARD SURFACE (FLUSH) i I PGE TRAAISFORMSRS MUST BE WITHIN 15 FEET OF A DRIVEABLE AREA. Fhfl Strtng Top Section Slips FINAL GRADE IF SOFT SURFS F. i I ' t ALWAYS MAINTAIN 10 FEET CLEARANCE IN FRONT OF ALL TRANSFORMERS. Swe Taped b Over Stub of Conduit a 13x24x18"DEEP OR �' 9. STEEL BARRIER POSTS ARE REQUIRED AROUND TRANSFORMERS THAT ARE EXPOSED r GROUND ROD INSTALLED BY 17'530 x18"DEEP rwe s CUSTOMER PGE APPROVED TO VEHICLES Sad Grade JUNCTION NED BY PGE - •-- ._:. i 10.10 FEET (PREFERRED) PUBLIC UTILITY EASEMENT (P.U.E) TO BE 8 FEET (MIN) Section Finish RADIUS 9ftEND' 11. CONSULT WITH POE REPRESENTATIVE 2 WEEKS BEFORE STARTING MAIN POWER See Note 2 TRENCHING FOR A PRECONSTRUCTION CONFERENCE. INCLUDED IN THIS CONFERENCE For Installing 1"PVC SCH 40 ELECTRICAL GRADE WILL BE EXCAVATOR,PGE,TELCO,CATV,AND GAS. Sheet Metal Leo w Empty TO OPTIONAL ST LT POLE Screws � I'Selaw Finish Grade 12. CUSTOMER TRENCH AND ELBOW CONFIGURATIONS,ALL CONDUIT,VAULT AND PAD TLeave Extra INSTALLATIONS MUST BE INSPECTED BY PGE PRIOR TO BACKFILLING.WHEN YOU ARE Rock For lkwall READY FOR PGE TO INSPECT (AFTER INSTALLATION IS COMPLETE) CALL 503-736-5450 OR 503-463-4348 (SALEM AREA) .ALLOW UP TO 2 WORKING DAY FOR INSPECTION TO OCCUR. 2^OR 3"PVC SCH oto e�40 GREY PVC FACTORY BENDS CONTACT SERVICE COORDINATOR REFER TO THE PGE ELECTRIC SERVICE REQUIREMENTS BOOKLET FOR SPECIFIC REQUIREMENTS. ELECTRICAL GRADE STEEL OR PGE APPROVED FIBERGLASS BY PGE) OR RUNS OVER 150',OR 180 DEGREES FOR TRENCH AND CONDUIT INSPECTION PRIOR 13• DESIGN IS BASED ON STANDARD UNDERGROUND EQUIPMENT.NON-STANDARD UNDER- (DETERMINEDoR MORE IN BENDS) To BACKFILL.PGE WILL NOT INSTALL WIRE GROUND EQUIPMENT MAY BE AN OPTION AT AN ADDITIONAL COST TO THE CUSTOMER. rOP WEW W OF COMPACTED UNTIL TRENCH IS WIc BACKFILLED. Sea Note I 36"Radius Elbows AROUND S BACKFILL SERE COORD/NA7OR PGE CONSTRUCTION DRAWING 3'V tea: Depending on Installation STREET�IT�TOPOLE UNDER SPLICE BOX AND 3g3�33-6TiDv OR --5,t3-a la DATE: X018 SCALE. AccouNr: 8070001 Awo: 1000004600 oB NO.M2320746 Crashed Rock 2"OR 3" CONDUIT p^OR 3" �� CONDUIT INSTALL GROUND ROD AND ANY DEVIATION FROM THIS DESIGN MUS a PGE 11�J�R HIT '�Q'® POLE BOTTOM PIECE POLE INSTALLATION CONDUIT ON THE SOURCE SIDE BE APPROVED BY PGE PROJECT MANAGER uRcurr SIZE GROUND Notes: RODNMURRYHILL- MURRYHILL 11x17 I. Tamped 34-i�Runus crushed roar ball PGE is required around all poles and footings CALL 811 BEFORE YOU DIG LOCATION regardless of soil condition to maintain R E ON L 13327 SW LAURMONT CT,TIGARD prop-poo a4um ne,t OREGON LAW REQUIRES YOU TO FOLLOW RULES ADOPTED 2. Imp 2-, 314-� scnsws BY THE OREGON UTILITY NOTIFICATION CENTER. DESCRIPTION (PGE AN 02522)We apart through Ite THOSE RULES ARE SET FORTH IN OAR 952-001-WIOguLdA ® Ind:circuit. 3®'DB FG Brrra PI(25'mh)w 100W HPS T&C Coronad@ 240v to Prevent rotation of pole top. THROUGH 952-001-0090.YOU MAY OBTAIN COPIES OF COUNTY N(S) WORK WITH SHEET THE RULES BY CALLING THE OREGON UTILITY BEAVERTON WASHINGTON Cll-33D I OF I NOTIFICATION CENTER ADMINISTRATION @ (503-232-1987) UNE CREW CENTER DESIGN BY PHONE(503) DRAWN BY INSTALL 30AMP FUSES IN SECONDARY PEDESTALS OR SECONDARY VAULTS (WHICHEVER IS ST LT POINT OF ATTACHMENT)FOR EACH TO REQUEST UTILITY LOCATES CALL THE OREGON Know wWs below. 2213 SW 153RD DR ,lose Grojedo 672-5602 LANE WHITNEY STREET LIGHT PER PGE T&D CONSTRUCTION STANDARD LC-11550 UTILITY NOTIFICATION CENTER,811 AT LEAST WAMTON,OR 97006 2 BUSINESS DAYS PRIOR TO EXCAVATION. C®I�before you dig. ®PORTLAND GENERAL ELECTRIC CO.-ALL RIGHTS RESERVED