Plans (176) c T 40 --- \ • 0410E1 00 . . .. .. . . . . . . CT ENGINEERING :•: •: : . CT • • • • • • INC • • 180 Nickerson St. Suite 302 • • • • • ••• • • • Coattle•Wi 981090 • • • ••• • • i • • • • : : •:: (216)28S-1512(V): : • • 151 •• ••• • (206)285-0618(F) asolomon@ctengineering.com ••• ••• • • •• •• • • •• • •• • •• • •• • BULLETIN • • :•• •••• •• • • • • • Date: April 6,2016 Number:CT-02 Project#: 15238 Project Name: River Terrace SF Attached: None Subject: Lots 18& 23—Patio Roof Truss Connection Drawings Affected: Description/Action: This bulletin provides response to RFI, design clarifications and/or variation requests for the 'River Terrace Single-Family' project located in Tigard, Oregon. The patio roof trusses shall be attached to the home using a 2x6 ledger with (3) 0.131"x3" nails to each wall stud. This application applies to all of the plan types in the River Terrace single-family development. PR G 1 N4-`'fit ic th • REC�iNA 04/06/2016 CALL WITH ANY QUESTIONS Issued by: Arnold R. Solomon Date: April 6, 2016 Distribution: Contact Information: Chris Walther Polygon Northwest Company Maggie Gordon Polygon Northwest Company Rick Tolleshauq Milbrandt Architects Alexia Fukui Milbrandt Architects R:\15238 River Terrace\Bulletins\15238_2016.04.06 CTO2 Jots 18&23(Patio Roof Truss Connection).doc Structural Engineers