Loading...
Plans (126) 2 O O t h O Fk ikrO o rn >im SCOPE OF WORK FIRE ALARM EQUIPMENT SYMBOL LIST 3dfg SYMBOL DESCRIPTION PART # I ROUGH-IN / NOTE MOUNTING HEIGHT W V INSTALL A NEW ADDRESSABLE CENTRAL STATION ARE ALARM SYSTEM WHICH O INCLUDES A FIRE ALARM CONTROL PANEL, CENTRAL STATION OFF-SITE NOTIFIER SELF-CONTAINED SURFACE MOUNT 54" TO TOP OF HIGHEST Y REPORTING, SPRINKLER FLOW AND TAMPER VALVE MONITORING, A MANUAL PULL FACP ARE ALARM CONTROL PANELNFW-50 19"H X 16.65"W X 5.25"D USER FUNCTION AFF i STATION, AND A SMOKE DEFECTOR. DSC SELF-CONTAINED SURFACE MOUNT IES CELLULAR DIALER3G4010-CF 11.5"H X 10"W X 3"D ALIGN WITH OTHER EQUIPMENT a El WATER FLOW SWITCH BY OTHERS MONITORED BY NMM-100P . t 11%111 GENERAL NOTES Q TAMPER SWITCH BY OTHERS MONITORED BY NMM-100P i similli i A ®M ADDRESSABLE INPUT MODULE - MINI NMM-100P NOTIFIER SINGLE GANG ALIGN WITH OTHER EQUIPMENT i 11111114 1. THE FIRE ALARM SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 72 AND NFPA 70, ARTICLE 760, POWER LIMITED SYSTEMS. 2. FIRE ALARM WIRE INSTALLED IN VERTICAL RUNS AND PENETRATING MORE F ADDRESSABLE MANUAL PULL STATION NOTIFIER 4" SQUARE, SINGLE GANG, OR 46" TO CENTER AFF THAN ONE FLOOR SHALL BE RISER RATED. NOT-BG12LX DOUBLE GANG BACK BOX 3. FIRE ALARM WIRE RUN IN DUCTS OR PLENUMS SHALL BE PLENUM RATED. COPY NOTIFIER 4. ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT. OFFICE r jj NOTIFIER 5. A SYSTEM GROUND MUST BE PROVIDED FOR EARTH DEFECTION AND { 2D NP-100 4" OCT OR SINGLE GANG CEILING MOUNT PHOTOELECTRIC SMOKE DETECTOR LIGHTNING PROTECTION DEVICES. 6. DEDICATED BRANCH CIRCUIT(S) AND CONNECTIONS SHALL BE MECHANICALLY 24 VOLT WATER FLOW BELL GENTEX GENTEX GBBB WEATHER PROOF G86-24 BACK BOX 96" AFF 7. CIRCUIT DISCONNECT MEANS SHALL HAVE A RED MARKING,IDENTIFIED AS "FRE ALARM CIRCUIT". CITY OF TIGARD 8. AUDIBLE ALARMS SHALL CONFORM TO SECTION 18.4.3 PUBUC MODE (NFPA 72). EWED FOR CODE COMPLIANCE IV' ED 9. CENTRAL STATION MONITORING SHALL BE DOCUMENTED UPON CO,, , QvODE 10. AOF THE RECORD OFIECT IN COMPLETION SHALLE BEITH SECTION 26.6.3 PROVIDED TO THE FIELDA 72)._rowed: SE PR AT THE ACCEPTANCE TEST INSPECTION IN ACCORDANCE WITH (` ' I OMP COMPLETED NEPA 72 MAY ZO)$ !V SECTION 14.6.2.4 (NFPA 72). OTC: I n Permit#: RECORD OF CITY OF TIGARD121 ��5 9 R- Oa' 4 ' COMPLETtOt3 AT BUILDING DIVISION Address: 7S C.O ,c‘,.. nu r h Gm r4. fiNAL`NSPECTION m Suite#: � ) (,) - a_ I W By: Date: ,,c- ) A— pti UJ UJ I— FIRE ALARM OPERATIONAL MATRIX Q ›— SITE SITE SYSTEM OUTPUTS = Cl) CY o 2 � •P'' V) a0 r/ & qP oQ` P Q Q o W 0 .coO Q FP<8� y��Y 5 5� P� 1 42 .01'436- PS �t<, Owl�� 0 S`' OQ� PJ°�S`O�O OJw CO Ur L� PSC' 0\ON �s°�s� JP JP 4, :7:;NOTES: 0 � LLde SYSTEM INPUTS P��P�� R`�R`� 5°� �� P°�P°�P°� ��� � REVIEWED/APPROVED: , r PULL STATION • • • • SMOKE DETECTOR • • • • - ). Cl2 , SPRINKLER FLOW SWITCH • • • • • BEN BREIT-4460LEA 5`' SPRINKLER TAMPER SWITCH • • DWG REV./DATE �F 0 04/24/18 Q COMMUNICATOR TROUBLE • • 1 05/03/18 LDG 2 / y�F,�( LOSS OF AC POWER AT FACP • • �/ N DRAWN BY: (� OPEN CIRCUIT • • TME DISCONNECTION OF BATTERIES • • CHECKED BY: ill II,IIIIII GROUND FAULT • • BJB III1V 111111 „ , , FILE NAME: PRESS SIGNAL SILENCE KEY • • FA.dwg PRESS RESET KEY • DRAWING#: FA-1 ORIG.SHEET SIZE:11"x 17" #OF DWGS IN SET: SHEET 1 OF 4 �n o o r�o BATTERY CALCULATIONS #.o O NOTIFIER NFW-50 W K N o PART # DESCRIPTION QTY STANDBY STANDBY TOTAL ALARM ALARM TOTAL ADDRESS SCHEDULE g Y NFW-50 MAIN CIRCUIT BOARD 1 0.1200 0.1200 0.2000 0.2000 2 g ADDRESS DEVICE LOCATION / AREA NOT-BG12LX PULL STATION ADDR 1 0.0003 0.0003 0.0003 0.0003 D-01 PHOTO SMOKE DETECTOR BY FACP NP-100 PHOTOELECT ADDR HEAD 1 0.0003 0.0003 0.0065 0.0065 NMM-100P MINI MONITOR MODULE 4 0.0004 0.0016 0.0050 0.0200 M-02 MONITOR COMM TROUBLE BY FACP z GB6-24 FIRE ALARM BELL 1 0.0000 0.0000 0.1000 0.1000 M-03 PULL MANUAL PULL STATION BY WF/TS a STANDBY TOTAL 0.1222 ALARM TOTAL 0.2268 M-04 FLOW WATER FLOW *CALCULATIONS BASED ON 24 HR STANDBY TIME & 5 MIN ALARM TIME* M-05 '. A TAMPER TAMPER CHECH AMPS (A) X TIME (H) = AMP-HRS (AH) 20% DERATE M-O6 TAMPER DOUBLE CHECK VALVE le 111 STANDBY 0.1222 X 24 = 2.9328 - A-07 SPARE SPARE a ALARM 0.2268 X 0.0833 = 0.0189 - A-08 SPARE SPARE TOTAL AH = 2.9517 3.5420 A-09 SPARE SPARE A-10 SPARE SPARE BATTERIES TO BE INSTALLED: 7.0 AH *** SPARE CONTINUES *** A-50 I SPARE SPARE D- DETECTOR M- MODULE A- SPARE N 13 J 00 2 I W FIRE ALARM RISER DIAGRAM w H (TYPICAL) Q () D-01 M-02 M-03 M-04 M-05 M-O6 ©. ® 0 ® ® m a Q SLC FPLR . \ CO 2 /�/ DM a ® a 1 BY OTHERS fl EOL_ EOL_ IEOL IR EOL_ Q = J 47kne 47k de 47kn e 47kne 100 FACP Co W M oQ � 0 NOTE: NAC 1 PROGRAMMED AS Q _ LL SLC 1 SPECIAL AUX POWER DWG REV./DATE SLC NOTIFIER 1 0 04/24/18 18/2C FPLR NFW-50 2 1 SPARE ZZ EOL_4.7kn 1 05/03/18 RJ FACP Ea W/INTEGRAL RJ I-- DACT TYPICAL NAC NOTIFICATION CIRCUIT SCHEDULE 14/2C FPLR DRAWN BY: VOLTAGE DROP CALCULATIONS TME 120VAC DEDICATED CCHECKED BY: BJB CIRCUIT TOTAL WIRE WIRE VOLT VOLT ACCEPTED VOLT CKT # DEVICE LOCATION / AREA ORIGIN AMPS DIST SIZE DROP AT EOL DROP DROP % FILE NAME: FA.dwg N-1 WATERFLOW BELL AT FDC FACP 0.100 25 14 0.02 20.38 YES 0.08% N-2 SPARE SPARE FACP 0.000 0 14 0.00 20.40 YES 0.00% DRAWING#: END-OF-LINE METHOD OF CALCULATION FA-2 ORIG.SHEET SIZE:11"x 17" #OF DWGS IN SET: SHEET 2 OF 4 �n o omo aro'6; m J D w s v © wD NV N f 1 Q r 1 i__s, _. N CD BELLQ ELEC/MECH/ J B RISER CO D-01 FACP 2 WI-'^ 1 FAC�AIM>M-02 A DOC Ce V J • � 1E1M03 IM04 �/�a M05 - = VJ_ li V 1�� _ 7 O6 a I �/ L L L 2 LL 2 FtM Q c” N2 0O to Cl FLOOR PLAN ° 8' 16' 32' o ° < U 0 0 OVERALL NE DWG REV./DATE SCALE: 1/16”=1'- ��� ROLL UP DOOR 0 04/24/18 1 05/03/18 DRAWN BY: \''''--.- TME - CHECKED BY: BJB - FILE NAME: FA.dwg DRAVNNG#: 00 ENLARGED PLAN _ _ 8' 16' FA-3 im SCALE: 1/8"=1'-0" ORIG.SHEET SIZE:11"x 17" #OF DWGS IN SET: SHEET 3 OF 4 o A,o ono u;oE, no ci d N o O,o L-, LOLBa w(A w FROM FACP TO NEXT DEVICE OR OR PREVIOUS DEVICE �_ �J �� TO FACP FOR 10/1 \\ OPTIONAL CLASS A m 111 ,f SLC INSL (TYPICAL,encl SLC SLC + Iffiavi-"H-- iikil (TYPICALLOUT OTO NEXT DEVICE TO NEXT DEVICE OR TO FACP FOR OR TO FACP FOR __________________ OPTONAL CLASS A al CLASS X • \ SLC- SLC- SLC_ • SLC _ �/ FROMOORACP SLC IN SLC OUT FROM FACP SLC IN SLC OUT PREVIOUS DEVICE (TYPICAL 18/2C) (TYPICAL tent) OR PREVIOUS DEVICE (TYPICAL 18/2) (TYPICAL 10/2C) SLC+ • SLC+ CAUTION: SLC+ • SLC + DO NOT LOOP WIRE UNDER TERMINAL 1 OR 2. MONITOR MODULE MONITOR MODULE BREAK WIRE RUN TO PROVIDE SUPERVISION OF CONNECTIONS. SEE ADDRESS SCHEDULE FOR 6 7 6 9 =0 6 7 6 9 COIRESPCNDWIG MODULE. 6�7 6 ` 7-13-9 BASE-B2t0LP \/--L/// ADDRESS I\/-`-/ SET DIAL(S)ACCORDINGLY. \ 4 I_I�1 ADDRESS Art 41_' 1 PHOTO SMOKE DETECTOR Ei 21,-- 21,"- Alp "— 3\-\ J 3\- 1 HEAT DETECTOR Z1, Z1O TENS LOOP ONES TENS LOOP ONES _! • • • • • • (-) (+) (+) (-) ®SMOKE/HEAT BASE YELLOW VIOLET RED `BLACK J YELLOW VIOLET RED BLACK SCALE: NTS FLOW OR TAMPER SNITCH TYPICAL 18/2C 1 1/4... / ` TYPICAL 18/2C PLACED HERE;NOTE EOLR k.. Tvwrx,enc N LOCATION ON EACH. -\ 1 \.. J TAMPER SWITCH TYPICAL CC /n PADDLE FLOW SWITCH , v NC NCS PAM-2 •NC NC• C—�_ „..___...0 C \ 47Ko R:KD®' TYPICAL WHITE •OV(-) C• BLS UES 4 m R� NO NO c--•NO NOL _./ � �+24V(aT0.015A NC YELLOW , Ill PLACE EOLR AS SHOWN PLACE EOLR AS SHOMN FOR TAMPER SNITCH FOR PADDLE FLOW SNITCHS Al2VI5C.01SA NO• ORANGE Cl) IX "`FOR USE WITH FLOW SWITCH"` FROM FACP SLC v, TO NEXT DEVICE EOL )•ICD / FACP AUX l OR SLC IN SLC OUT OR Q / \ PREVIOUS DEVICE ("P..L,aACI (TYPICAL 18/2C) TO FACP FOR O + 24VDC GENTEX 24VDC $L,(;+ SLC + OPTIONAL CLASS A '^ TYPICAL 102C POWER FLOW BELL IL TYPICAL 192C , , `/J / e - OUT GB6-24 ` ^^ Q O O CAUTION: BLACK(IN) BLACK(OUT) DO NOT LOOP WIRE UNDER m m m m m m m m m 5 m m m m m m m m m 0 s s 0 TERMINAL 1 OR 2. - c Ch TYPICAL 18/2C I-I t UNU�ppF� BREAK WIRE RUN TO PROVIDE 1- v 8 i D $j w + 0 0 9 5 C N ' CONDUCTORS Z 1` F G = _ < F i� Q N SUPERVISION OF CONNECTIONS. O O111.3 O O v I N" (+) O O (+) DSC3G4010CF .�I. DSC-3G4010CF RED(IN) II RED(OUT) I _ _ POWER SUPPLY 4 PGM4IS OPTIONAL BECAUSE TERMINAL BLOCKS I - 0 DIAL TONE IS NOT " i GENERATED WHEN CELL ��� � SIGNAL IS LOST ®FLOW BELL/TAMPER SWITCH MONITOR �� _ ®I. COMM TROUBLE MONITOR Q o 1 SCALE: NTS SCALE NTS �_ ��� DWG REV./DATE 0 04/24/18 . e 1 05/03/18 3 DRAWN BY: MITME CHECKED BY: PULL STATION BJB FILE NAME: ® dwg PULL STATION FANG SCALE: NTS DRAWING#: FA-4 ORIG.SHEET SIZE:11"B 17" #OF DWGS IN SET: SHEET 4 OF 4