Report • PRT/PK-CABLE: Cable printer/personal computer interface DNR: InnovairFlex low-flow non-relay duct-detector housing. cable. (Order NP-100R separately.) PRN-6: UL listed compatible event printer. Uses tractor-fed DNRW: InnovairFlex low-flow non-relay duct-detector housing, paper. with NEMA-4 rating. Watertight.(Order NP-100R separately.) IPDACT, IPDACT2/2UD Internet Monitoring Module: NMM-100: Addressable Monitor Module for one zone of nor- Mounts in bottom of enclosure with optional mounting kit(PN mally-open dry-contact initiating devices. Mounts in standard IPBRKT). Connects to primary and secondary DACT tele- 4.0" (10.16 cm.) box. Includes plastic cover plate and end-of- phone output ports for internet communications over customer line resistor. Module may be configured for either a Style B provided ethernet internet connection. Requires compatible (Class B)or Style D(Class A)IDC. Teldat Visoralarm Central Station Receiver.Can use DHCP or static IP. (See data sheet dn-60408 for more information.) NDM-100: Dual Monitor Module. Same as NMM-100 except it IPBRKT:Mounting kit for IPDACT-2/2UD in common enclosure. provides two Style B(Class B)only IDCs. NMM- LED IPSPLT: Y-adaptor option allows connection of both panel and Stye D option. Co nects with wire pigtails. Maydmoun in dialer outputs to one IPDACT-2/2UD cable input. device backbox. AC-TRMBLK:AC Terminal Block mounts to a metal bracket,in NZM-100A:Similar to NMM-100A.Addressable Monitor Mod- turn, mounts to the FACP chassis. Use AC-TRMBLK when ule for one zone of conventional two-wire detectors. Requires wire nuts are not allowed for AC connections to the trans- resettable 24 VDC power. Refer to the Device Compatibility former. Document for listed compatible devices and quantity limita- OPTIONAL MODULES tion. NZM-100-6: Six-zone interface module. Mount one or two 4XTM Reverse Polarity Transmitter Module: Provides a mod- supervised output for local energy municipal box transmitter, idesmodon in a -6Bchassis cabinet BB-2(optional).aMount up to six alarm and trouble. Includes a disable switch and disable trou- ble ides a CHS-6 in a BB-25 cabinet. LED. NMM-100-10: Ten-input monitor module. Mount one or two modules in a BB-2 cabinet(optional).Mount up to six modules ANN-SEC: Optional secondary ANN BUS interface module. firmware 3.0 or higher. on a CHS-6 chassis in a BB-25 cabinet. Note:Used only with COMPATIBLE ANNUNCIATORS NC-100:Addressable Control Module for one Style Y/Z(Class N-ANN-80(-W):Remote LCD annunciator mimics the informa- Mounts directly to a 4.0"(10.16 cm.)electri aB/A) zone of survised polarized ltion box.Notification tion displayed on the FACP LCD display. Recommended wire Appliance Circuit option requires external 24 VDC to power type is un-shielded. (Basic model is black;order-W for white; notification appliances. see DN 7114.) NC-100R: Addressable relay module containing two isolated N-ANN-I/O: LED Driver Module provides connections to a sets of Form-C contacts, which operate as a DPDT switch. user supplied graphic annunciator.(See DN-7105.) Mounts directly to a 4.0"(10.16 cm.)box,surface mount using N-ANN-LED: Annunciator Module provides three LEDs for the SMB500. each zone: Alarm, Trouble, and Supervisory. Ships with red NOT BG12LX:Addressable manual pull station with interface enclosure.(See DN-60242) module mounted inside. N-ANN-BLED: Provides alarm (red) indicators for up to 30 N100-ISO:Fault Isolator Module. input zones or addressable points.(See DN-60242.) SMB500:Used to mount all modules except the NMM-100P. N-ANN-RLY: Relay Module provides 10 programmable Form- NOTE:For more information on Compatible Addressable Devices C relays. Can be mounted inside the cabinet.(See DN-7107.) for use with the FireWarden-50, see the following data sheets N-ANN-S/PG: SeriaVParallel Printer Gateway module pro- (document numbers):N100-ISO(DN-6994), NP(-100 series(DNN- vides a connection for a serial or parallel printer. (See DN- 6995), N/-100 (DN-6996), NH-100/NH-100R (DN-6997), DNR/ 7103.) lnnovairFlex(DN-60424, DN-60429), NP-A100(DN-6998), NMM- 100/NMM-100P/NDM-100AMM--100 (DN-6999), NC-100 (ON- ADDRESSABLE DEVICES 7000), NC-100R(DN-60383), NMM-100-10(DN-6990), and NOT- All feature a polling LED and rotary switches for addressing. BG 12LX(DN-7001). NI-100:Addressable low-profile ionization smoke detector. ADDRESSABLE DEVICE ACCESSORIES NP-100:Addressable low profile photoelectric smoke detector. End-of-Line Resistor Assembly (R-47K and R-3.9K): The 47k ohm NP-100T: Addressable low-profile photoelectric smoke detec- NMM 1 OOP,assembly d NC 100 module cir ui ervises the s00The 3.9k ohm tor with thermal sensor. assembly supervises the NZM-100-6 module circuit. These NP-100R: Remote test capable addressable photoelectric resistors are included with each module. smoke detector for use with DNR(W)duct detector housing. Power Supervision Relay: Supervises the power to 4-wire NH-100:Fast response,low-profile heat detector. smoke detectors and notification appliances. NH-100R: Fast-response, low-profile heat detector with rate- of-rise option. Wiring Requirements While shielded wire is not required, it is recommended that all NH-100H: Fast-response, low-profile heat detector that acti vales at 190°F/88°C. SLC wiring be twisted-pair to minimize the effects of electrical interference.Refer to the panel manual for wiring details. NP-A100:Addressable low-profile multi-sensor detector. DN-7102:E•02/22/2011—Page 3 of 4 • SYSTEM SPECIFICATIONS System Capacity (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the • Intelligent Signalling Line Circuits 1 useful life of the system's standby batteries and the electronic • Addressable device capacity components may be adversely affected by extreme tempera- Programmable software zones 50 ture ranges and humidity. Therefore, it is recommended that • 20 this system and its peripherals be installed in an environment • Annunciators 8 with a normal room temperature of 15—27°C/60—80°F. Electrical Specifications NFPA Standards AC Power: FireWarden-50: 120 VAC, 60 Hz, 3.0 A. FireWar- The FireWarden-50 complies with the following NFPA 72 Fire den-50E:240 VAC,50 Hz,1.5 A.Wire size:minimum 14 AWG Alarm Systems requirements: (2.00 mm2) with 600 V insulation. Nonpower-limited, super- —LOCAL (Automatic, Manual, Waterflow and Sprinkler vised. Supervisory). Battery: Two 12 V 18 AH lead-acid batteries. Battery Charger —AUXILIARY(Automatic, Manual and Waterflow)(requires Capacity: 7-18 AH(FireWarden-50 cabinet holds maximum of 4XTM). two 18 AH batteries.) —REMOTE STATION (Automatic, Manual and Waterflow) Communication Loop: Supervised and power-limited. (Where a DACT is not accepted, the alarm, trouble and Notification Appliance Circuits: Terminal Block provides supervisory relays may be connected to UL 864 listed connections for two NACs,Style Y(Class B)or Style Z(Class trouble,4XT ForM is requiequiree polarity signaling of alarm and trouble,4XT A). Special Application power. Power-limited, supervised red.) cir- cuitry. Maximum signaling current per circuit: 2.5 A. End-of —PROPRIETARY(Automatic,Manual and Waterflow). Line Resistor:4.7k ohm,'/ watt(P/N 71252 UL listed)for Style —CENTRAL STATION (Automatic, Manual and Waterflow, Y(Class B)NAC.Refer to the NOTIFIER Device Compatibility and Sprinkler Supervised). Document for listed compatible devices. —OT, PSDN (Other Technologies, Packet-switched Data Two Programmable Relays and One Fixed Trouble Relay: Network) Contact rating: 2.0 A @ 30 VDC (resistive), 0.5 A @ 30 VAC ' (resistive).Form-C relays,nonpower-limited,nonsupervised. Agency Listings and Approvals Cabinet Specifications den-50 control The listings and approvals beeloaw easpplyce rtoa inthe basic FireWar- Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x certain panel. be listed bppro al ag ncies,ort listingg mayy be in p - 0.72" (1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x cess.Consult factory for latest listing status. 16.65" (42.29 cm.) wide x 5.25" (13.34 cm.)deep. Trim Ring • UL:S635 (TR-CE/B):22.00"(55.88 cm.)high x 19.65"(49.91 cm.)wide. • FM approved Shipping Specifications • CSFM:7165-0028:239 Weight:26.9 lbs. (12.20 kg.)Dimensions:20.00"(50.80 cm.) • MEA:442-06-E Vol.2 high x 22.5"(57.15 cm.)wide x 8.5"(21.59 cm.)deep. NOTE:See DN-60446 for ULC-listed model. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 — 49°C/32 — 120°F and at a relative humidity 93% ± 2% RH NOTIFIER®, FireWarden®, and System Sensor® are registered trademarks of Honeywell International Inc. Microsoft®and Windows®are registered trademarks of the Microsoft Corporation. ©2011 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. .�� C E FITF 1 E O We cannot cover all specific applications or anticipate all requirements. - .�. �� ENCIIIEBMRRAMAMMAS All specifications are subject to change without notice. QUALITY SYSTEMS .10............ For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. Made in the U.S.A. www.notifier.com Page 4 of 4—DN-7102:E•02/22/2011 DBD From Tyco Security Products Activating & Initializing the Unit Rate Plan Activating and initializing the 3G4010CF can be done using Cost-effective rate plans have been negotiated and are the automated telephone activation system(VRU), mobile available through authorized master resellers.Contact your interface or web-user interface provided by monitoring station or visit www.connect24.corn to find a C24 Communications.No special tools are required. master reseller.When used as a sole communicator,the 3G4010CF requires use of the 4MB(NFPA72 2010)or Mobile Site for Easy Installation and 500kB(NFPA72 2013)rate plans to support the supervision Comprehensive Maintenance requirements. C24 Communications mobile site(m.connect24.com) makes the installation a simple process and offers intuitive Specifications trouble-shooting features, cutting down on time and cost Dimensions allocated to maintenance. 11-1/2"x 10"x 3" (290 mm x 254 mm x 75 mm) Input Voltage 120 VAC Current Draw 200 mA(standby) 400 mA(transmitting) Operating Environment 32°to 120°F(0°to 49°C) — 0 IZEIEIE. 0—..... Weight 12.8 lbs(5.8 kg)il < ; O m 0NOZIni=ing=a Si® Optional Acessories UL Listing Model Description The 3G4010CF is UL listed under File S4019, Listin GS-15ANIT 15 R extensionantenna(internal use) g guide GS-25ANT 25 ft extension antenna UOXX,as a sole or backup communicator for Commercial Fire monitoring installations.When used as a sole communicator (i0ft a extensionnal use) under NFPA72 2010 guidelines the 3G4010CF will send GS-50ANT 50 f# antenna its heartbeat once every 97 seconds ensuring that three (itemaVexternal use) heartbeats will be received at the supervising station within the 300 second window.When used as a sole communicator under NFPA72 2013 guidelines the 3G4010CF will send its heartbeat once every 5 minutes to monitor connectivity with the supervising station within the 1 hour window. When used as a backup communicator the 3G4010CF will monitor the other communication method(DACT)and send a daily test transmission to the supervising station. CSFM Listing The 3G4010CF has been approved by the California State Fire Marshal(CSFM)pursuant to Section 13144.1 of the California Health and Safety Code. Ordering Information: 3G4010CF-USA Universal Wireless Commercial Fire Alarm Communicator i. (U.S. ModeVSIM Card Included) :0, Z a communications For product information www.dsc.com I[L,1 Is t d nt o n O I 11 r.P s t .,rang cut no r t ruin f odi rr i ,11tn,I f,iir ma o 31 dm 1,1 or rs.I st eniemar,s OfOtherC ,n'g 'x;2019 T5rno SonorS F(o5mrfo 1 • r Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm)wide x • Built-in type identification automatically identifies this device 0.65"(1.651 cm)deep. as a monitor module to the panel. Wire length:6"(15.24 cm)minimum. • Powered directly by two-wire SLC loop.No additional power required. NZM-100(A) Interface Module • High noise(EMF/RFI)immunity. • Supports compatible two-wire smoke detectors. • Tinned,stripped leads for ease of wiring. • Supervises IDC wiring and connection of external power • Direct Decade entry of address: 01 — 99 on FireWarden- source. 100-2,01 —50 on FireWarden-50. • High noise(EMF/RFI)immunity. N • SEMS screws with clamping plates for ease of wiring. 3 1415 0 1 ADDRESS 0 1 • Direct Decade entry of address:, 01 —99 on FireWarden- g 13 2 2 100-2,01 —50 on FireWarden-50. 3 12 �� 3 �, 11 �%v// 4 LOOP �� 4 • LED flashes during normal operation. 10 5 5 • LED latches steady to indicate alarm on command from 9 .' 7 6 9 8 7 6 control panel. TENS ONES The NZM-100(A)Interface Module is intended for use in intelli- n n n n gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wireO W Y conventional smoke detectors.It transmits the status(nor- J J U mal,open,or alarm)of one full zone of conventional detectors W 0 5 back to the control panel. All two-wire detectors being moni- >- CO tored must be UL compatible with the module. NZM-100(A) APPLICATIONS Use the NZM-100(A) to monitor a zone of two-wire smoke I I I detectors. The monitored circuit may be wired as an NFPA Style B(Class B)or Style D(Class A)Initiating Device Circuit. The NMM-100P(A) Mini Monitor Module can be installed in a A 3.9 K ohm End-of-Line Resistor (provided) terminates the single-gang junction directly behind the monitored unit. Its end of the Style B or D (class B or A)circuit(maximum IDC small size and light weight allow it to be installed without rigid loop resistance is 25 ohms). Install ELR across terminals 8 mounting.The NMM-100P(A)is intended for use in intelligent, and 9 for Style D application. two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiat- NZM-100(A)OPERATION ing device circuit for normally-open-contact fire alarm and Each NZM-100(A) uses one of the available module security devices. NMM 100P(A) addresses on an SLC loop. It responds to regular NMM-100P(A)APPLICATIONS lls fro the control panel and reports its type and the status(open/nor Use to monitor a single device or a zone of four-wire smoke mal/short)of its Initiating Device Circuit(IDC).A flashing LED detectors,manual fire alarm pull stations,waterflow devices,or indicates that the module t incommunicationnalarm (subjectwith the control Trent other normally-open dry-contact devices. May also be used to panel.t The LED latches steady on to current monitor normally-open supervisory devices with special super- visory limitations on the loop). indication at the control panel. Monitored circuit/device NZM-100(A)SPECIFICATIONS is wired as an NFPA Style B(Class B)Initiating Device Circuit. Nominal operating voltage: 15 to 32 VDC. A 47K ohm End-of-Line Resistor(provided)terminates the cir- cuit. Maximum current draw:5.1 mA(LED on). NMM-100P(A)OPERATION Maximum IDC wiring resistance:25 ohms. Average operating current: 300 NA, 1 communication and 1 Each NMM 100P(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from LED flash every 5 seconds,3.9k eol. the control panel and reports its type and the status(open/nor- EOL resistance:3.9K ohms. mal/short)of its Initiating Device Circuit(IDC). External supply voltage (between Terminals T3 and T4): NMM-100P(A) SPECIFICATIONS DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum.Current:90 mA per module maximum. Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 pA, 1 communication every Temperature range:32°F to 120°F(0°C to 49°C). 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Humidity range:10%to 93%noncondensing. Shorted). Dimensions: 4.5" (11.43 cm) high x 4° (10.16 cm) wide x Maximum IDC wiring resistance:40 ohms. 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x Maximum IDC Voltage: 11 Volts. 2.125"(5.398 cm)deep box. Maximum IDC Current:400 pA. EOL resistance:47K ohms. Temperature range:32°F to 120°F(0°C to 49°C). Humidity range: 10%to 93%noncondensing. Page 2 of 4—DN-6999:C•10/06/2010 NDM-100(A) Dual Monitor Module • MEA: 72-01-E Vol. 2 (NMM-100, NMM-100P, NZM-100); The NDM-100(A) Dual Monitor Module is intended for use in 227-03-E Vol.3(NDM-100) intelligent, two-wire systems. It provides two independent two Product Line Information wire initiating device circuits(IDCs)at two separate,consecutive addresses. It is capable of monitoring normally open contact fire NOTE:A"suffix indicates ULC-listed model. alarm and supervisory devices.The module has a single panel- NMM-100 A:Monitor module. controlled LED. ( ) NOTE: The NOM-100(A)provides two Style B(Class B)IDC civ- NMM-100P(A):Monitor module,miniature. cults ONLY Style D(Class A)IDC circuits are NOT supported in NZM-100(A):Monitor module,two-wire detectors. any application. NDM-100(A): Monitor module, dual,two independent Class B NDM-100(A)SPECIFICATIONS circuits. Normal operating voltage range:15 to 32 VDC. SMB500:Optional surface-mount backbox. Maximum current draw:6.4 mA(LED on). NOTE: See installation instructions and refer to the SLC Wiring Average operating current:750 pA(LED flashing). Manual,PN 52304. Maximum IDC wiring resistance: 1,500 ohms. , Maximum IDC Voltage: 11 Volts. Maximum IDC Current:240 pA EOL resistance:47K ohms. Maximum SLC Wiring resistance:40 Ohms. Temperature range:32°to 120°F(0°to 49°C). Humidity range: 10%to 93%(non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 2.125"(5.398 cm)deep. NDM-100(A) AUTOMATIC ADDRESSING The NDM-100(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the NDM-100(A) is set to address "26", then it will automati- cally assign itself to addresses"26"and"27". NOTE: `Ones"addresses on the NDM-100(A)are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address,and terminals 8 and 9 use the second address. QCAUTION: Avoid duplicating addresses on the system. Installation NMM-100(A), NZM-100(A), and NDM-100(A) modules mount directly to a standard 4'(10.16 cm)square,2.125'(5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installa- tion instructions are provided with each module. All wiring must conform to applicable local codes,ordinances,and regu- lations. These modules are intended for power-limited wiring only. The NMM-100P(A) module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordi- nances,and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UL:S635 • ULC:S635 • FM Approved • CSFM: 7300-0028:0230 (NMM-100, NMM-100P, NZM- 100);7300-0028:0237(NDM-100) DN-6999:C•10/06/2010—Page 3 of 4 within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel,send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. Product Line Information NOT BG12LX: Dual-action addressable pull station. Includes key locking feature. (Listed for Canadian and non-Canadian applications.) SB-10:Surface backbox;metal. SB-UO:Surface backbox;plastic. BG12TR:Optional trim ring. 17021:Keys,set of two. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess.Consult factory for latest listing status. • UL/ULC Listed: S692(listed for Canadian and non-Cana- dian applications). • MEA:67-02-E Vol.IV. • CSFM:7150-0028:0199. • FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. NOTIFIER®is a registered trademark of Honeywell International Inc. ©2012 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. 1SO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. C E R T F 1 E D We cannot cover all specific applications or anticipate all requirements. BIMMIMIMI I MAMIMICTMEYI All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-7001:D•4/13/2012 • Detector Sensitivity Test NP-100RA:Same as NP-100R with ULC Listing for use with a Each detector can have its sensitivity tested (required per DNRA duct detector housing;B210LPA base included. • NFPA 72,Chapter 14 on Inspection, Testing and Maintenance) INTELLIGENT BASES when installed/connected to a FireWarden-100-2 or FireWar- NOTE:"A"suffix indicates ULC Listed model. den-50 addressable fire alarm control panel.The results of the sensitivity test can be printed off the FireWarden-100-2 or Fire- NOTE:For details about intelligent bases and their mounting,see Warden-50 for record keeping. DN-60054. B210LP(A): Plug-in detector base (included); standard U.S. Specification flanged low-profile mounting base. Voltage range: 15-32 VDC(peak). B210LPBP:Bulk pack of B210LP;package contains 10. Standby current:300 pA 0 24 VDC. B501(A):Standard European flangeless mounting base. LED current:6.5 mA 0 24 VDC(latched"ON"). B501 BP: Bulk pack of B501;package contains 10. Air velocity:4,000 ft./min.(20 m/sec.)maximum. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Size:2.1'(5.33 cm)high;base determines diameter. Replaces B501 BH series bases in retrofit applications. -B210LP(A):6.1'(15.5 cm)diameter. B224RB(A): Plug-in System Sensor relay base. Screw termi- -B501(A):4.1"(10.4 cm)diameter. nals:up to 14 AWG(2.0 mm2).Relay type:Form-C.Rating:2.0 -B200SR(A):6.875"(17.46 cm)diameter. A © 30 VDC resistive; 0.3 A © 110 VDC inductive; 1.0 A CP -B224RB(A):6.2"(15.748 cm)diameter. 30 VDC inductive. Weight:3.6 oz.(102 g). B224BI(A): Plug-in System Sensor isolator detector base. Maximum 25 devices between isolator bases(see DN-6994). Operating temperature range: for NP-100(A):0°C to 49°C ACCESSORIES (32°F to 120°F);for NP-100T(A):0°C to 38°C(32°F to 1000F). NP-100R(A):installed in a DNR(A)/DNRW-20°C to 70°C(-4°F F110: Retrofit flange to convert B210LP(A) to match the to 158°F). B710LP(A) profile, or to convert older high-profile bases to Temperature:0°C-49°C(32°F-120°F). low-profile. Relative humidity: 10%-93%,non condensing. F110BP:Bulk pack of F110;package contains 15. F210: Replacement flange for B210LP(A)base. Listings RA100Z(A): Remote LED annunciator.3-32 VDC.Mounts to Listings and approvals below apply to the NP-100(A), NP- a U.S. single-gang electrical box. For use with B501(A) and 100T(A), and NP-100R(A) detectors. In some cases, certain B210LP(A)bases only. modules may not be listed by certain approval agencies, or SMB600:Surface mounting kit tuning may be in process. Consult factory for latest listing sta M02-04-0O:Test magnet. • UL Listed S1115. M02-09-00:Test magnet with telescoping handle. • ULC Listed:S911. XR2B: Detector removal tool. Allows installation and/or • CSFM:7272-0028:0231. removal of detector heads from bases in high ceiling applica- tions. • MEA:243-02-E Vol.2. XP-4: Extension pole for XR2B. Comes in three 5-foot(1.524 • Maryland State Fire Marshal:permit 2173. m)sections. • FM approved. T55-127-010:Detector removal tool without pole. Product Line Information BCK-200B:Black detector covers for use with NP-100(A)only; box of 10. NOTE:`4"suffix indicates ULC Listed model. WCK-200B: White detector covers for use with NP-100(A) NP-100: Adressable photoelectric detector; B210LP base only;box of 10. included. NP-100A:Sames as NP-100 with ULC Listing; B210LPA base included. NP-100T: Same as NP-100 but with thermal element; B210LP base included. NP-100TA: Same as NP-100T with ULC Listing; B210LPA base included. NP-100R: Remote test capable addressable photoelectric NOTIFIER® and FireWarden® are registered trademarks of Honeywell detector for use with a DNRA/DNRW duct detector housing; International Inc. B210LP base included. ©2011. All rights reserved. Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. CER -r•F 1 E D We cannot cover all specific applications or anticipate all requirements. 9MINEBIMC S MMNUC1IMYC All specifications are subject to change without notice. �� DUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2-DN-6995:C•12/07/2011 Notifier®and FireWarden®are registered trademarks and FireWatchTm is a trademark of Honeywell International Inc. ®2010 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. This document is not intended • 1S0 9001 o to be used for installation purposes. We try to keep our product information up-to-date and accurate. CERT 1 F 1 E We cannot cover all specific applications or anticipate all requirements. mminumnimm UMINEMINS I MAIM= All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 4 of 4—DN-6999:C•10/06/2010