Loading...
Permit CITY OF TIGARD ELECTRICAL PERMIT ---. COMMUNITY DEVELOPMENT Permit#: ELC2018-00216 Date Issued: 04/02/2018 t f GAR D 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S110BD04500 Jurisdiction: Tigard Site address: 11916 SW ELEMAR CT Project: GENDE Subdivision: ASPEN RIDGE Lot: 10 Project Description: (1)branch circuit for hot tub. Contractor: OWNER Owner: GENDE, MICHAEL J MIKE GENDE BURNS, MARK R 11916 SW ELEMAR CT 11916 SW ELEMAR CT TIGARD, OR 97224 PORTLAND, OR 97224 PHONE: PHONE: 503-998-6705 FAX: FEES Quantity Description Date Amount 1 crt Branch Circuits wo/Purchase 04/02/2018 $56.18 Specifics: Service or Feeder 1 ea 12%State Surcharge- 04/02/2018 $6.74 Type of Use: SF Electrical Class of Work: ALT Type of Const: Occupancy Grp: Total $62.92 Required Items and Reports(Conditions) This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 throu 52-001-0090. You may obtain a copy - .gs or direct questions to OUNC by calling 503.232 1987 or 1.800.332.234. / s ) /F— Issued By: Permittee Signature: OWNER INSTALLATION ONLY The installation is being made on property I own which is not intended for sale,lease or rent. OWNER'S SIGNATURE Date: CONTRACTOR INSTALLATION ONLY SIGNATURE OF SUPR.ELEC' Date: LICENSE NO. Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Electrical Permit Application FOR 01'FI( USE ONLY a ;-* 1° Received City Of Tigard Date/B : _ �/ r 13125 SW Hall Blvd.,Tigard,OR 97 Plan Review II Phone: 503.718.2439 2, 0 Date/B : Related Permit#: Email: TigardBuildingPermits@Tigard-or.OP R Ready Date/By: Id See Page 2 for 1 I G ARD Notified/Method: MM. Supplemental Information Inspection Line: 503.639.4175 Internet: ww��ar\- SON -,IO��gR�„� TYPE OF W/ � PLAN REVIEW ❑New construction ` '' �` +,ate Additon/altelbll3cement Please check all that apply(submit 2 sets of plans w/items checked): i 0 Service or feeder 400 amps or more 0 Building over three stories. 0 Demolition 0 Other: where the available fault current 0 Marinas and boatyards. CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or 0 Floating buildings. less to ground,or exceeds 14,000 0 Commercial-use agricultural El1-and 2-family dwelling 0 Commercial/industrial 0 Accessory building amps for all other installations. buildings. ❑Multi-family 0 Master builder 0 Other: 0 Fire pump. 0 Installation of 150 KVA or JOB SITE INFORMATION AND LOCATION 0 Emergency system. larger separately derived 0 Addition of new motor load of system. Job#: Job site address: I lei i(0 5G/i.(L'VL1e'I 100HP or more. ❑"A","E","1-z", `1-3", Q '] ❑Six or more residential units. occupancy. City/State/ZIP: T I G v,,, OR q79-7-14 ❑Health-care facilities. 0 Recreational vehicle parks. Suite/bldg./apt.#: Project name: 60/1/se..„ ❑Hazardous locations. 0 Supply voltage for more than 0 Service or feeder 600 amps or more. 600 volts nominal. Cross street/directions to job site: FEE SCHEDULE Description I Qty. I Each I Total I * New residential single-or multi-family dwelling unit. Subdivision: /� U Lot#: Includes attached garage. A,S P�� �t (� 1,000 sq.ft.or less 168.54 4 Tax map/parcel#: Ea.add'1500 sq.ft.or portion 33.92 1 II f / DESCRIPTION OF WORK Limited energy,residential 75.00 2 ..L to Shot -1" -1-tA 6) • —t'7[ "' � ' S - "- (with above,mq. lt) (� Q t it Limited energy,multi-family 75.00 2 residential(with above sq.ft.) .,CiIr • C` ' =1-. ' 1,4 I Renewable Energy 0 See Page 2 ►5 PR* ' RTY OWN' ' ❑ TENANT Services or feeders installation,alteration,and/or relocation Name: 1/1/1 I i .ez Cry el..C.,,, 200 amps or less 100.70 2 )) l�_// 201 amps to 400 amps 133.56 2 Address: (CII(/ s(di i L e v oiv CA i 401 amps to 600 amps 200.34 2 City/State/ZIP: ``,,c u✓)/ Q '1?��4. 601 amps to 1,000 amps 301.04 2 Phone:(G o3)6194 &'70 Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email: relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 1 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and- 701. 201 amps to 400 amps 125.08 2 Owner signature: Date: ` 1 1�:.1./(? 401 amps to 599 amps 168.54 2 APPLICANT; ❑ CONTACT PERSON Branch circuits–new,alteration,or extension,per panel A.Fee for branch circuits with Business name: above service or feeder fee, 7 42 2 each branch circuit Contact name: B.Fee for branch circuits without service or feeder fee,first ` 56.18 `7�;i ( 2 Address: branch circuit City/State/ZIP: Each add'I branch circuit 7.42 2 Miscellaneous(service or feeder not included) Phone:( ) Each manufactured or modular 67.84 2 dwelling,service and/or feeder Email: Reconnect only 67.84 2 CONTRACTOR Pump or irrigation circle 67.84 2 Business name: Sign or outline lighting 67.84 2 Signal circuit(s)or limited-energy ❑ See Page 2 2 Address: panel,alteration,or extension. Each additional inspection over allowable in any of the above City/State/ZIP: Additional inspection(1 hr min) 66.25/hr Phone:( ) Investigation(1 hr min) 90.00/hr Industrial plant(1 hr min) 78.18/hr Email: Inspections for which no fee is 90.00/hr CCB Lic.: Electrical Lic.: Suprv.Lic.: specifically listed('A hr min) ELECTRICAL PERMIT FEES Suprv.Electrician signature,required: Subtotal: 5.7,.I r Print name: Date: 0 Plan Review Required(25%of permit fee): State surcharge(12%of permit fee): 4..7 y TOTAL PERMIT FEE: 612_') Authorized signature: This permit application expires if a permit is not obtained within 180 Print name: Date: days after it has been accepted as complete. * Number of inspections allowed per permit. I:\Building\Permits\ELC_PermitApp_ELR_ERE.doc Rev 10/26/2017 440-4615T(11/05/COM/WEB Electrical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: RE FO NTI;AL WORK OivLYI FES SCHEDULE Fee for all residential systems combined: $75.00 DeeRennewew I I Each I Total * able electrical energy systemem s: Check Type of Work Involved: 5 kva or less 100.70 2 5.01 to 15 kva 133.56 2 ❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2 Wind generation systems in excess of 25 kva: H Burglar Alarm 25.01 to 50 kva 301.04 2 ❑ Garage Door Opener* 50.01 to 100 kva 552.26 2 >100 kva(fee in accordance with OAR 918-309-0040) 552.26 2 H Heating, Ventilation and Air Conditioning Solar generation systems in excess of 25 kva: System* Each additional kva over 25 7.42 3 ❑ Vacuum Systems* >100 kva—no additional charge 0.0 3 Each additional inspection over allowable in any of the above: ❑ Other: Each additional inspection is 66.25/hr 1 charged at an hourly(1 hr min) Inspections for which no fee is 90.00/hr specifically listed(A hr min) :COMIRCIAL WQ2K �ONLY: 'ELECTRICAL PE FEES WFee for each commercial system: $75.00 Subtotal(Enter on Paget): (SEE OAR 918-309-0000) * Number of inspections allowed per permit. Check Type of Work Involved: ❑ Audio and Stereo Systems n Boiler Controls n Clock Systems ❑ Data Telecommunication Installation ❑ Fire Alarm Installation ❑ HVAC ❑ Instrumentation ❑ Intercom and Paging Systems ❑ Landscape Irrigation Control* H Medical ❑ Nurse Calls ❑ Outdoor Landscape Lighting* ❑ Protective Signaling ❑ Other: Total number of commercial systems: *No licenses are required. Licenses are required for all other installations I:\Building\Permits\ELC_PermltApp_ELR_ERE.doc Rev 10/26/2017 City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 Location: Inspection Date: 11916 SW ELEMAR CT, TIGARD, OR, 97224 Record Type: Record ID: Residential - Electrical ELC2018-00216 Inspection Type: Inspector: 199 Electrical final Jeff Grove Result: PASS - NoCofO Comments: Violation Summary: Inspector Contractor