Plans Y Markup Legend / SPRINKLER SYMBOL DEFINITION Delete Line XXX-XX COLOR/LINETYPE LEGEND — — — tf BLUE LINES FEED TO FIXTURES(BATH,SHOWER,ETC.). o Add Line — — MAXIMUM SPACING(TYP) GREEN LINES,INTERLEVEL CONNECTIONS/SUPPLY. O BLACK LINES=SPRINKLER HEAD TO SPRINKLER HEAD. SPRINKLER MODEL(TYP) \ HEAD SYMBOL(TYP) - 1/2"PIPE SIZE ,1;,'° Add Tee �� �� f�7 =3/4"PIPE SIZE w a �4 a^@,° Add Elbow _ ( = = = 1-PIPE SIZE 0 amu m = 1-1/4"PIPE SIZE Add Coupling I I Sc. - • ..-...-. l CL u v W m O j • 1 Markup Legend SPRINKLER SYMBOL DEFINITION Delete Line /� XXX-Xx COLOR/LINETYPE LEGEND — — — } f BLUE LINES= FEED TO FIXTURES(BATH,SHOWER,ETC.). z N Add Line I MAXIMUM SPACING(TYP) GREEN LINES=INTERLEVEL CONNECTIONS/SUPPLY. ° SPRINKLER MODEL(TYP) BLACK LINES=SPRINKLER HEAD TO SPRINKLER HEAD. O w s 8 Add Tee HEAD SYMBOL(TYP) J �r� = 1/4"PIPE SIZE 8^ 1 - =3/4"PIPE SIZE C - = 1"PIPE SIZE O a ,,u S' Add Elbow _ = 1-1/4"PIPE SIZE ' 11>z Add Coupling CIO u v LL O CL^�� Add Head -qi 1\--�.2 �3\ Z o1 ��v mN2am Delete Head O om'�w?. Q o E.5 _¢GCZ`� Move Head -O- O_ �r �ydo Cowoi zd� ho--26` Note:All revisions must be reviewed by Uponor w> o E 5 wOV-n,.SZ2,4 _0. Table F002-1 Multipurpose Fire Safety Systems ,---,..<. ° g z.5 o The Uponor Residential Fire Safety System is a residential fire protections ,r,'o`o o d` _-r z system installed in combination with the cold side of the domestic potable o o<❑> N�,- w -z ooam<¢oomYFo water system. Only licensed contractors trained by Uponor can install this ?.p?c c z g system. a Ez.zwooj<¢' Wso-o r> z 3: Qw What fetoatures do if Changes are Required 2 o a c<�_z � Q o O If any features or obstructions require the addition or deletion of sprinkler .Q.I.1''..-‘-',,z .,04.--x-''''' 7'.z o o o.o oz a.z c UFC O heads,or significant relocation of sprinkler heads,contact the Uponor Design V a z Q _<�y Department to determine if observed changes require a redesign „may w¢ c‹o Q z z° Q>, (888.594.7726). 1, ., ) �, 6 t- 02x6VZoz c, S 17 s It ht ISI'- r:; biz oo ��< mE.o LA L — - I'-',/ 4, Q D .c Il L —,, �, — �� �zx��o�1z o � RES16 E �I.� i�� — ..,,,`")‹...' "CL,-,7°"'‹ i� O.O> U.Z (, S.1 MAIN SHUTOFF z z r Ir.` s � � r>: E 00003 H2 VALVE LOCATION z>zo�o III • -_ t , f �i _ r 'I 1 IF �w�Euo¢u� sr-oz� w II r L I14fi m I I F TR! ..fJLt� - Master Bedl �S-,� �' / H.11 i.tIF F I I �'"4 1-Ye"AquaPEX TOem �N--,,-,--„„- � III1-5 L r '' L� SYSTEM Ta Garage ad eCar h g RC-RES-16 �„ FL _ t r"'_,,,AN'-y ,5 r I here by certthat this Ian,specification, ill /41 F- F H i r- or report was prepared by me or under my TI _T�� SRC-RES-16dizrar! l LI�Ing � I. Il _i 1 Iii 'L-T,-3-1- L Ce tified atLevel V. that l am NICET L- L _9___ --. -- �. ..__ v I: direct CO _t`T } .� [ - Brent Kotula el E �- �r � �2� T 1$ PPnn _ rh�G en / _ Date: g o.113889 i "— FLOOR TO THIRD FLOOR �� t I' .I 1'AQUAPEX INTERLEVEL -(} -� T4J11�1 `rte— .r, ### --- / 1p /' LJ C� _7t 111 = CONNECTIONS FROM SECOND —I— 2 \ �_ / H.5 � h n , 1r t,- 16 �'-" - I t M.26 r _ _ PoG ES II / li t F �2 RC 6 h ��/ Art t �.�/ \�i.,----i----, 7 II 1 �iH �� 11,_7_,:__,,,, _� /� B - , -t � - - CONNECTIONS FROM FIRST -r 1 �L =r. z F =1 I0 , — BC Fs n6 — , , / fi t` J G T Q INTERLEVEL L 1"A UAPEX L F} 1 »� RES 14 73` F.6 j 7 r , FLOOR TO SECOND FLOOR \ F.4 Ili T.33 I T�34 �— • oi: + — 1 /1 �/ " P�� ,rdt�-'�,. - II .Cr -+� � �`�Ij`Q' 7 C f� A V 'I � 'r n t it r —.,'!-'-‘1.' / 1 4 ',� .�`� ''�-�. 6� "t1. .\ U �1'. \ �.----- ii ,, S 1 % j .,7 v�� Q m^o al _s 1111—:L, ' ' ' cf m N v IIS_ � S i _a° -- li 1, M : / il' \ \ ,...:�I�� , --� � � a°��,.,. fl fi� ro - � 4IHRC-R S U w f '- -, \ \ .35 Entry '—' Jr� 'C-RES-1-6 v 1 - w u 3 T �� a U--1 (Y1 a�aso� ��Rria.� - FA" I� (n °° RC-RES-18 plc �� I Ni o I Tech Rm. � > I B! co- ` Bedroom 2 i r - Y 1 Din./Fam H 15 4 ce _ I I \ P=� ,,,,_[_'L',[!: RL�f�E 1g J i_. Porch w ,_'l Pwdr. , 11, 2 _ � T I 1^.O moo 1 SII ami�� �I j - II U � . -1,— � Z >eg S �"� =m w = o o= V 3 THIRD FLOOR r 1 r Ce n F- Lr,3 6 P 2 SECOND FLOOR - Fi w FIRST FLOOR F101 =� a ii i �1 1/4n = i �_Qn F101 i I� = 11 - SHEET DESCRIPTION 1 1/4 1 -Q F101 , 1/4" /^I� = J �_oII ALL LEVELS-MIRROR 5 `t1 SHEET NUMBER iii- W5 15 ,...7, 1/4"=1'_0" © UPONOR - CONFIDENTIAL F101 • AquaSAFE'"' GENERAL NOTES: Senju RC-RES:Open Web Truss/TJI Construction Insulation Recommendations ProPEX LF Brass Fire In areas subject to freezing,care should be taken in unheated attic spaces See General Notes 8.2.5.7 for Architectural `t 1. THIS SYSTEM IS DESIGNED AS PER NFPA 13D 2016 EDITION AS A RESIDENTIAL MULTIPURPOSE SYSTEMto cover Uponor Aqua PEX tubing completely with insulation. Insulation '-^ Sprinkler Adapter Tee Feature Requirements SECTION 3.3.11.3. Blocking Maybe Fire Sprinkler Adapter should follow the guidelines of the insulation manufacturer. See Uponor .n Document"Uponor AquaSAFE Attic Insulation Guidlines"for attic z 00 2. UPONOR COMPANY RESERVES THE EXCLUSIVE RIGHTS TO ALL DETAILS AND DRAWINGS AS SHOWN ON Required.If -Push-on Nut installation guidelines(Provided in Contractors Documents package or online \ / E z THIS SHEET. THESE DETAILS AND DRAWINGS ARE PROPRIETARY INFORMATION OF UPONOR COMPANY AND Blocking is Used, at www.0 O 'w Use The 2 Top � 11/4"Min. ponorpro.cow). UNAUTHORIZED USE MAY BE SUBJECT TO PROSECUTION TO THE FULL EXTENT OF THE LAW. Screw Holes. �- C I� 1�"Max. / ?^O _ J Bottom of Mountinu Extreme Temperature Installations Planter Box Window,Bay Window or Similar Feature. a 3. THE DESIGN OF THIS SYSTEM IS DICTATED BY SPECIFIC CEILING HEIGHTS AND ROOM SIZES. IT IS THE I Bracket to Face of Truss RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO ENSURE THAT THE CONDITIONS SHOWN ON THESE �� AquaSAFE Residential Fire Safety systems are often installed in attics or If no adtlitinal floor area is created No Additional Sprinkler is Required. Fire Sprinkler AdaOter- -I I-/ other areas exposed to temperature extremes of heat and/or cold. Follow n G Ou PLANS ARE EXACTLY AS THEY EXIST IN THE FIELD. DEVIATIONS FROM THE DESIGN MAY CAUSE THE Mounting Bracket 8'-0"or less O a a.w a SYSTEM TO BE UNABLE TO CONTROL A FIRE.IF THE BUILDING CONSTRUCTION DIFFERS FROM THE FIRE ��ll_9/ the recommended extreme weather installation instructions to isolate and / ,-'-2 'm protect system components from extreme temperatures. Because this SPRINKLER PLAN,CONTACT THE SYSTEM DESIGNER IMMEDIATELY. //�� RC-RES-16,, m a w Q 3-#10 x 1/2" iY},� system also delivers domestic cold water directly to plumbing fixtures, �\ CM u w 4. THIS SYSTEM AND THE ACCOMPANYING HYDRAULIC CALCULATIONS ARE DESIGNED IN COMPLIANCE WITH Full Cour-- I I -� Uponor highly recommends that you protect the tubing with adequate / 9'-0"or less ;N z O NFPA 13D 2016 EDITION. m Thread Screws b' i--f insulation in warm weather areas to minimize heating of the cold water W ft'2,:' cs In Botto Holes CJ supply. \ - a W 3 5. "STAND-ALONE"OR"MULTIPURPOSE,WET PIPE"SYSTEMS ARE NOT PERMITTED TO USE ANTI-FREEZE. �� _6 m o 3 -- \ Installation methods include,but are not limited to: o 6. MODIFICATIONS ARE PROHIBITED.SPRINKLERS THAT HAVE BEEN PAINTED,CAULKED,MODIFIED OR • - ^' b m''`g,' a m DAMAGED MUST 8E REPLACED. Lead-Fres Flat Tenting over the fire sprinkler piping. ` I o o\11 / \ w `''.'6 f w Conceale•Senju -` • ��` • Additional layers of batt insulation. O 10 F w 3 Concealed Flat If additional, oefloor area is created.Cannot exceed 18 ft',be more than 2'-0" WATER SHUT OFF VALVE IS NOT PERMITTED THAT ISOLATES THE SPRINKLER SYSTEM. Sprinkler Head • Increased depth of blown-in insulation. deep,more than 9'-0"wide and be with in the coverage area of the 7. Cover Plate ¢ z sprinkler.No Additional Sprinkler is Required. 8. OWNERS MANUAL MUST BE PROVIDED TO THE OWNER. Caution: If you will be installing spray foam insulation,make sure to R.,;,, i-4,78,,,,,,6.8 LL z '',',Et.',' oz-ccF Senju RC-RES:Traditional Wood Framing Construction Protect all components during application.Consult with the spray foamz =F 9. AT THE MAIN SHUT OFF VALVE,A TAG OR A SIGN STATING THE FOLLOWING IS REQUIRED;"WARNING,THE manufacturer to ensure compatibility with all products before application. NFPA 13D Table 7.5.5.3 Distances From ,.,`,.`.E217,..-- t LL o s s WATER SYSTEM FOR THIS HOME SUPPLIES FIRE SPRINKLERS THAT REQUIRE CERTAIN FLOWS AND >z z a o PRESSURES TO FIGHT A FIRE.DEVICES THAT RESTRICT THE FLOW OR DECREASE THE PRESSURE OR Heat Sources J w z ¢ w s w w Consultation with local building officials is encouraged to ensure compliance e c p m z o d, ft ft AUTOMATICALLY SHUT OFF THE WATER TO THE FIRE SPRINKLER SYSTEM,SUCH AS WATER SOFTENERS, ProPEX L'Brass Fire with local building codes. FILTRATION SYSTEMS AND AUTOMATIC SHUT OFF VALVES,SHALL NOT BE ADDED TO THIS SYSTEM Sprinkler dapter Tee Fire Sprinkler Adapter :4,,.'P ',5'5'7 o ft o m_' z o Q WITHOUT REVIEW OF THE FIRE SPRINKLER SYSTEM BY A FIRE PROTECTION SPECIALIST.DO NOT REMOVE Push-on Na Ordinary Intermediate ..,-,, z-,-,;,'‹ Heat Source Temp. Temp. -z h o z aF THIS SIGN". 135°-170° 175°-225' o o a.,:f w,,-_ ITh 1I'II Bending PEX Tubing zz¢o ,.`mz o 10. ALL INTERIOR PIPING TO BE UPONOR"Aqua PEX®"UNLESS NOTED. 1�/q'Min. The minimum bend radius of Uponor PEX tubing in any direction is six times Side of Fireplace 36" 12" S c z a o 0 z 1%'Max. the outside diameter(6 x OD). Front of Fireplace 60" 36" >w o a 11. UPONOR"Aqua PEX"TUBING TO BE SUPPORTED PER NFPA 13D AND MANUFACTURER'S RECOMMENDATIONS. Fire Sprin ler Adapter Bottom cf Mounting Bend supportsW mom 0 p P¢i,z s¢4 are available for 3/6",1/2",3/4"and 1"Uponor Aqua PEX Wood Burning Stove 42" c_ c= ,-.,z¢ O J Mounting Bracket `_- Bracket to=ace of cross12" --w a z,z O 'T= tubing to facilitate e degree rigid bends. Kitchen Range 18" t"t e z°'-z`� ¢°- MINIMUM SPACING BETWEEN SPRINKLERS IS 8'-0" REFER TO SPACING CHARTS FOR MAXIMUM SPACING + 9° Q,z u o=_o o'-¢<>3 z BETWEEN SPRINKLERS AND FROM WALLS.SPRINKLER HEAD MANUFACTURERS MAY HAVE MORE 2-#10 x 1/2" Wall Oven 18" 9" U a z G w<w a�m12. h?o o RESTRICTIVE SPACING LIMITATIONS. Full Cour-- Recommended Tubing Length Between Fittings V)z N C LL y c o u,v.u �- Hot Air Flues 18" g„ N wdo� zz _ ¢hw Thread S.rews Fitting Size Minimum Tubing Length Ode oflHot Heat Ducts 18" d p E..a o u v: 13. SPRINKLERS ARE NOT NECESSARILY CENTERED IN ROOMS DUE TO LIGHT FIXTURES OR OTHER CEILING In Top H.les 111=11.1/ i♦ 9" D o i e i- -z o z w MOUNTED OBSTRUCTIONS. - 3/8"ProPEX Fitting 2„ Uninsulated Hot Water Pipes 12" 6" ?w F N - z o z_N a courwft �= 1/2"ProPEX Fitting 2 1/2.. Side Hot Air Diffuser 24" 12" c 3 o z 14. THE PLUMBING TIE IN CONNECTIONS ARE SCHEMATIC IN NATURE AND CAN BE INSTALLED OFF THE Front of Hot Air Diffuser 36" d d°d!' �'- `�'i SPRINKLER LOOP ANYWHERE BETWEEN SPRINKLER TO SPRINKLER CONNECTION. - 3/4"ProPEX Fitting 3 1/2" 18" 3,,,LL'E ,, ¢w¢ Lead-Fre: z E a ,7 - Hot Water Heater ¢'0 0'5<�u orw�� 15. THIS SUGGESTED LAYOUT IS BASED UPON INFORMATION PROVIDED BY OTHERS. CHANGES IN Conceale• enju = =e--- 1"ProPEX Fitting3 o v o w z o Y..U N Sprinkler Head Concealed Flat 4 1/2" Furnace 6" o o x o CONSTRUCTION OR FIELD CONDITIONS MAY OCCUR WHICH MAY REQUIRE CHANGES TO THE LAYOUT. ]T IS Cover Plate 1 1/4"ProPEX Fitting S 1/2" SOW-250W Light Fixture 6" 3^ '0 o o m'a x d="-z ft=0 THE RESPONSIBILITY OF THE INSTALLER TO NOTIFY UPONOR TECHNICAL SERVICES OF SUCH CHANGES. u x u o x°U ¢s 25OW-499W Light Fixture 12" x y:. a 6 - i36o� z 16. NFPA 13D 8.2.5*OBSTRUCTIONS TO RESIDENTIAL SPRINKLERS a • 8.2.5.6* SHADOW AREAS SHALL BE PERMITTED IN THE PROTECTION AREA OF A SPRINKLER AS LONG AS Exposed Installation Requirements. \ ,-,,,,u_.,00, m>F,c c¢o"ax 0 0 0 w THE CUMULATIVE DRY AREAS DO NOT EXCEED 15 FT'PER SPRINKLER. \ ¢c,u z z L c z a Uponor AquaPEX'"'tubing(white)and ProPEX-""EP Fittings and ProPEX" I a • 8.2.5.7 SMALL AREAS CREATED BY ARCHITECTURAL FEATURES,SUCH AS PLANTER BOX WINDOWS,BAY Brass Fittings are approved for exposed installation where the following WINDOWS,AND SIMILAR FEATURES,SHALL BE EVALUATED AS FOLLOWS: conditions are met.(UL 1821 Approved) (1)WHERE NO ADDITIONAL FLOOR AREA IS CREATED BY THE ARCHITECTURAL FEATURE,NO ADDITIONAL SPRINKLER PROTECTION IS REQUIRED. Exposed Wood Joist Ceiling Assemblies. ,;,•.3 /�O am (2)WHERE ADDITIONAL FLOOR AREA IS CREATED BY AN ARCHITECTURAL FEATURE,NO ADDITIONAL 1. Joists are of dimensional lumber,engineered wood,wood I-joist or open /U SPRINKLER PROTECTION IS REQUIRED,PROVIDED ALL OF THE FOLLOWING CONDITIONS ARE MET; web wood joists. �� m I here by certify that this plan,specification, (a)THE FLOOR AREA SHALL NOT EXCEED 18 FTS(1.7 M�) 2. Joist are of depths from 6-16 inches(152-204 mm). rym or report was prepared by me or under my (b)THE FLOOR AREA SHALL NOT BE GREATER THAN 2 FT IN DEPTH AT THE DEEPEST POINT OF 3. Joist are of spacing from after1installation.-24 inches(305-610 mm)on center, direct supervision and that 1 arn NICET under THE ARCHITECTURAL FEATURE TO THE PLANE OF THE PRIMARY WALL WHERE MEASURED 4. Joists can be exposed 6111 Certified at Level IV. ALONG THE FINISHED FLOOR. 5. Metal pipe hangers spaced at maximum 24 inches(610 mm)on center \ 1.55" \ (c)THE FLOOR SHALL NOT BE GREATER THAN 9FT IN LENGTH WHERE MEASURED ALONG THE are used. 1.66" PLANE OF THE PRIMARY WALL. 6. Listed residential sprinklers of maximum activation lu 3n / Brent 0 Kotula (d)MEASURED FROM THE DEEPEST POINT OF THE ARCHITECTURAL FEATURE TO THE SPRINKLER temperature rating of automatic sprinklers . 2 -4 Hanger 1�� Hanger SHALL NOT EXCEED THE MAXIMUM LISTED SPACING OF THE SPRINKLER. Date: Reg.No.113889 ro (3)THE HYDRAULIC DESIGN SHALL NOT BE REQUIRED TO CONSIDER THE AREA CREATED BY THE Metal Tubing Support. Tubing Support Spacing: ARCHITECTURALDESIGN S E. u' 1. Metal tubing supports designed for plastic tubing shall be used. (Anchor Aqua PEX Tubing Securely Enough to Support the Tubing,Yet Relaxed 17. NFPA 13D 8.3 LOCATION OF SPRINKLERS. 2. Do not use supports that will damage the tubing.Inspect metal Enough to Allow the Tubing to Expand and Contract) • 8.3.1 SPRINKLERS SHALL BE INSTALLED IN ALL AREAS EXCEPT WHERE OMISSION IS PERMITTED BY 8.3.2 supports for sharp edges. THROUGH 8.3.8. 3. Do not rigidly anchor Uponor movement Xn"'tubing with supports. 1. Along Horizontal Runs,Install Supports Every 32",if Horizontal Runs are Allow Continuously Supported,Place Tubing Su • 8.3.2 SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF 55 FTS(5.1 M�)AND LESS enough tubing for freedom of movement to expand and contract. 9 pports a[Six-Foot Intervals. • 8.3.3 SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS,LINEN CLOSETS,AND PANTRIES THAT 2. Along Vertical Runs,Install Supports Every Four to Five Feet,at Each MEET ALL OF THE FOLLOWING CONDITIONS: Floor and at a Mid-story Guide. (1)THE AREA OF THE SPACE DOES NOT EXCEED 24 FT'(2.2 M'). z o (2)THE WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE In-linehe Flow Test m f a MATERIALS AS DEFINED IN NFPA 220,STANDARD ON TYPES OF BUILDING CONSTRUCTION. If the Upstream Pressure The In-line Flow Test can be constructed on site. It performs a flow test to LF x o • 8.3.4* SPRINKLERS SHALL NOT BE REQUIRED IN GARAGES,OPEN ATTACHED PORCHES,CARPORTS,AND ensure ,A SIMILAR STRUCTURES If the upstream pressure exceeds 80 psi a pressure reducing valve may proper system operation and flow(see Figure F001-8). v J p o v need to be installed. Some jurisdictions mayu ., • 8.3.5 SPRINKLERS SHALL NOT BE REQUIRED IN ATTICS WITH OR WITHOUT STORAGE,PENTHOUSE j require a pressure reducing z ft° '^, n ,t EQUIPMENT ROOMS,ELEVATOR MACHINE ROOMS,CONCEALED SPACES DEDICATED EXCLUSIVELY TO AND valve regardless of upstream pressure. $m of o ry CONTAINING ONLY DWELLING UNIT VENTILATION EQUIPMENT,FLOOR/CEILING SPACES,ELEVATOR SHAFTS, / Uponor AquaPEX Ti p o a j Tubing 1 1 1 w u, CRAWL SPACES,AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENDED FOR LIVING •. . m • PURPOSES. / w 8.3.5.1 SUCH SPACES THAT CONTAIN FUEL-FIRED EQUIPMENT SHALL ALSO COMPLY WITH 8.3.5.1.1 OR LLJ F� f 8.3.5.1.2. z F • 8.3.5.1.1 WHERE THE FUEL-FIRED EQUIPMENT IS ABOVE ALL OF THE OCCUPIED AREAS OF THE DWELLING > o_ o < zO w UNIT,NO SPRINKLER PROTECTION SHALL BE REQUIRED IN THE CONCEALED SPACE. • ( l �/ • 8.3.5.1.2 WHERE FUEL-FIRED EQUIPMENT IS BELOW OR ON THE SAME LEVEL AS OCCUPIED AREAS OF THE i .- -.-"--7'.----L-'-'---"' __ j U L.L G DWELLING UNIT,AT LEAST ONE QUICKRESPONSE IS INTERMEDIATE TEMPERATURE SPRINKLER SHALL BE /` v) NI M a F z Q a.F O o INSTALLED ABOVE THE EQUIPMENT OR AT THE WALL SEPARATING THE SPACE WITH THE FUEL-FIRED Male Threaded Coupling-/ ProPEX Fire V/ N O o o¢a usi z p EQUIPMENT FROM THE OCCUPIED SPACE. g O `D • 8.3.6 SPRINKLERS SHALL NOT BE REQUIRED IN COVERED,UNHEATED PROJECTIONS OF THE BUILDING AT Sprinkler Adapter a, ENTRANCES/EXITS AS LONG AS THE DWELLING UNIT HAS ANOTHER MEANS OF EGRESS. W cc C • 8.3.7 SPRINKLERS SHALL NOT BE REQUIRED FOR CEILING POCKETS THAT MEET THE FOLLOWING To Hot Water Heater Male Threaded Coupling 1"Ball Valve CO1-1 Vi CONDITIONS: ti LL (1)THE TOTAL VOLUME OF ALL UNPROTECTED CEILING POCKETS IN A COMPARTMENT DOES NOT EXCEED ,/ Female Threaded 100 FTs(2.83 M'). _ Tee with Water L,L z (2)THE ENTIRE FLOOR UNDER THE UNPROTECTED CEILING POCKET IS PROTECTED BY THE SPRINKLERS > ( Pressure Gauge 5 m Pressure Gauge Sprinkler Orifice = O o ir AT THE LOWER CEILING ELEVATION. u u (Optional) m m N (3)*THE INTERIOR FINISH OF THE UNPROTECTED CEILING POCKET EXCLUDING DECORATIVE w \ o co o w TREATMENTS IS NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE MATERIAL. Y Main Fire Sprinkler Flow Test Ce ki)1 Q f z z m d ,o (4)SKYLIGHTS NOT EXCEEDING 32 Fig(2.97 MIT SHALL BE PERMITTED TO HAVE A PLASTIC COVER. - Shut-off Valve m o 8.3.8 SPRINKLERS SHALL NOT BE REQUIRED IN CLOSETS IN GARAGES AND EXTERIOR CLOSETS v To ensure the system provides enough water for proper fire sprinkler W LU ce m a m w o' OF" _ performance,you should conduct a flow verification test. m" u> (REGARDLESS OF SIZE)LOCATED ON EXTERIOR BALCONIES,EXTERIOR BREEZEWAYS/CORRIDORS,OR Uponor Warning Signs \ Q -, ACCESSED FROM OUTDOORS WHERE THE CLOSET DOES NOT HAVE DOORS OR UNPROTECTED o Note: The NFPA 13D Installation Standard does not require flow H r Fj "' > =W m PENETRATIONS DIRECTLY INTO THE DWELLING UNIT. verification. `.J �y�Q z z o¢ 'v • 8.3.9 SPRINKLERS SHALL BE INSTALLED IN ANY CLOSET USED FOR HEATING AND/OR AIR-CONDITIONING a Pressure Reducing 7 EQUIPMENT,WASHERS AND/OR DRYERS,OR WATER HEATERS EXCEPT AS ALLOWED BY 8.3.8. Before by Z ~ 3 w z _ Valve performing a flow verification test,confirm the water pressures contacting the Water and Sewer Department of your local city. Ensure the x=w d O L 18. INSULATION GUIDE LINES PER NFPA 13D. available water pressure matches the pressure used in the system design. a u t,m z w • 9.1SU WET PIPE SYSTEMS IN AREAS ABOVE 40.F. A WET PIPE SYSTEM SHALL BE PERMITTED TO BE TO BE _ USED WHERE ALL PIPING IS INSTALLED IN AREAS MAINTAINED ABOVE 40.F,INCLUDING AREAS PROPERLY • Note: The sprinkler plan indicates the most hydraulically remote sprinkler SHEET DESCRIPTION ,e INSULATED TO MAINTAIN 40oF. (or pair of sprinklers). For test requirements on other sprinklers,consult GENERAL NOTES&DETAILS •• A.9.1.1 IN AREAS SUBJECT TO FREEZING,CARE SHOULD 8E TAKEN IN UNHEATED ATTIC SPACES TO 7i- INSULATED your local code. °„' COVER SPRINKLER PIPING COMPLETELY WITH INSULATION. INSTALLATION SHOULD FOLLOW THE ,o GUIDELINES OF THE INSULATION MANUFACTURER.FIGURE A.9.1.1(A)THROUGH FIGURE A.9.1.1(F) Note: It is a good idea to notify the fire inspector at least 24 hours prior to spe d c SHOW SEVERAL METHODS THAT CAN BE CONSIDERED. THESE ARE FOR ILLUSTRATIVE PURPOSES ONLY. performing a flow verification[est This may test f up the inspection 8 CONSULTATION WITH THE GENERAL CONTRACTOR AND/OR OWNER IS RECOMMENDED TO ENSURE process and eliminate the need to repeat the test for the inspector. SHEET NUMBER PROPER METHODS AND MATERIALS ARE USED TO MAKE SURE 400F WILL BE MAINTAINED. Note: See"AquaSAFE Flow Test Instruction Sheet"(Provided in Contractors Documents package or online at www.Uponorpro.com)for more information on Flow Test Setup,Assembly,Performing the Test and Troubleshooting. If there are any questions please contact Uponor. fJ IPRVSettPessurel © UPONOR - CONFIDENTIAL FO 0 1