Loading...
Report (99) PLEASE PROVIDE M S 71-0( �- 00012. COMPLETED NFPA 72 l Z.cC S i,l RECORD OF COMPLETION AT FINAL INSPECTION RECEIVED FEB 1 b 2018 5863 Lakeview Blvd, #100 N?" Lake Oswego, 97035 ��CITY ��'`1`I�aARD (503)627-0100 01100 CORPORATION BUILDING DIVISION FIRE ALARM TABLE OF CONTENTS Gabel Center — Bldg C 12115 SW 70th Ave. Suite 200 Tigard, OR 97223 Drawing Notifier— NMM-100P Addressable Input Module System Sensor— P2WL Horn/Strobe, Wall, White, Std. Candela System Sensor— SWL Strobe, Wall, White, Std. Candela System Sensor— SCWL Strobe, Ceiling, White, Std. Candela Monitor Modules DN-6999:C NMM-100(A), NMM-100P(A), N OT I Fl E R® NZM-100(A), and NDM-100(A) for FireWarden Series Panels by Honeywell Intelligent Addressable Devices General Four different monitor modules are available for Notifier's Fire- Warden Series intelligent control panels for a variety of appli- cations. Monitor modules supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull x% stations, or monitor and power a circuit of two-wire smoke detectors(NZM-100(A)). ; NMM-100(A)is a standard-sized module(typically mounts to a ' s 4" [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. NMM-100P(A) is a miniature monitor module a mere 1.3" ` ' (3.302 cm) H x 2.75" (6.985 cm) W x 0.5" (1.270 cm) D that supervises a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the NMM-100p(A) to be ` t mounted in a single-gang box behind the device it monitors. Ale fate NZM-100(A) is a standard-sized module that monitors and supervises compatible two-wire,24 volt,smoke detectors on a Style D(Class A) or Style B(Class B)circuit. NDM-100(A) is a standard-sized dual monitor module that NMM-100(A)(Type H) monitors and supervises two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at two separate,consecutive addresses in intelligent,two-wire systems. NMM-100(A) OPERATION NMM-100(A) Monitor Module Each NMM-100(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from • Built-in type identification automatically identifies this device the control panel and reports its as a monitor module to the control panel. mal/short)of its Initiating Device Cp cu t(IDC). Atye and thet (open/nor- us flash flashing LED • Powered directly by two wire SLC loop.No additional power indicates that the module is in communication with the control required. panel. The LED latches steady on alarm (subject to current • High noise(EMF/RFI)immunity limitations on the loop). • SEMS screws with clamping plates for ease of wiring. NMM-100(A) SPECIFICATIONS • Direct Decade entry of address: 01 —99 on FireWarden- Nominal operating voltage: 15 to 32 VDC. 100-2,01 —50 on FireWarden-50. Maximum current draw:5.0 mA(LED on). • LED flashes during normal operation and latches on steady Average operating current: 350 pA (LED flashing), 1 com- to indicate alarm. The NMM-100(A)Monitor Module is intended for use in intelli- munication every 5 seconds,47k EOL. gent, two-wire systems, where the individual address of each Maximum IDC wiring resistance:40 ohms. module is selected using the built-in rotary switches. It pro EOL resistance:47K ohms. vides either a two-wire or four-wire fault-tolerant Initiating Temperature range:32°F to 120°F(0°C to 49°C). Device Circuit(IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED Humidity range: 10%to 93%noncondensing. indicator. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x NMM-100(A)APPLICATIONS 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x Use to monitor a zone of four-wire smoke detectors, manual 2.125"(5.398 cm)deep box. fire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B(Class B)or Style D(Class A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. DN-6999:c•10/06/2010—Page 1 of 4 Dimensions: 1.3"(3.302 cm) high x 2.75" (6.985 cm)wide x • Built-in type identification automatically identifies this device 0.65"(1.651 cm)deep. as a monitor module to the panel. Wire length:6"(15.24 cm)minimum. • Powered directly by two-wire SLC loop. No additional power required. NZM-100(A) Interface Module • High noise(EMF/RFI)immunity. • Tinned,stripped leads for ease of wiring. • Supports compatible two-wire smoke detectors. • Direct Decade entry of address: 01 — 99 on FireWarden- • source.Supervises IDC wiring and connection of external power 100-2,01 —50 on FireWarden-50. • High noise(EMF/RFI)immunity. • SEMS screws with clamping plates for ease of wiring. i 1415 0 1 ADDRESS 0 1 • Direct Decade entry of address:, 01 —99 on FireWarden- 3 11,, 3 r1 2 100-2,01 —50 on FireWarden-50. �� 4 LOOP DI 4 • LED flashes during normal operation. 10 5 5 rii • LED latches steady to indicate alarm on command from 9 8 7 6 9 8 6 control panel. nTENS ONES The NZM-100(A)Interface Module is intended for use in intelli- n n n gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- O W Y wire conventional smoke detectors.It transmits the status(nor- () O U mal,open,or alarm)of one full zone of conventional detectors } O S back to the control panel. All two-wire detectors being moni- a� tored must be UL compatible with the module. NZM-100(A) APPLICATIONS Use the NZM-100(A) to monitor a zone of two-wire smoke I I I I detectors. The monitored circuit may be wired as an NFPA The NMM-100p(A) Mini Monitor Module can be installed in a Style B(Class B)or Style D(Class A) Initiating Device Circuit. Asingle-gang junction directly behind the monitored unit. Its end 3.9o K ohm Style EBof Line Resistor (procircuitvided)(maximum the small size and light weight allow it to be installed without rigid of the B or ohms).D lass B or A) R c (maximum IDC mounting. The NMM-100p(A)is intended for use in intelligent, loopresistancefor ylis 25pl Install ELR across terminals 8 two-wire systems where the individual address of each module and 9 for Style D application. is selected using rotary switches. It provides a two-wire initiat- NZM-100(A)OPERATION ing device circuit for normally-open-contact fire alarm and Each NZM-100(A) uses one of the available module security devices. NMM-100P(A) addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status(open/nor- NMM-100P(A)APPLICATIONS Use to monitor a single device or a zone of four-wire smoke mal/short)of its Initiating Device Circuit(IDC). A flashing LED detectors,manual fire alarm pull stations,waterflow devices,or indicates that the module is in communicationnalarm (subjectwith the control Trent other normally-open dry-contact devices. May also be used to panel. The LED latches steady on to current monitor normally-open supervisory devices with special super- visory limitations on the loop). indication at the control panel. Monitored circuit/device NZM-100(A)SPECIFICATIONS is wired as an NFPA Style B(Class B)Initiating Device Circuit. Nominal operating voltage: 15 to 32 VDC. A 47K ohm End-of-Line Resistor(provided)terminates the cir- cuit. Maximum current draw:5.1 mA(LED on). NMM-100P(A)OPERATION Maximum IDC wiring resistance:25 ohms. Average operating current: 300 pA, 1 communication and 1 Each NMM-100p(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from LED flash every 5 seconds,3.9k eol. the control panel and reports its type and the status(open/nor- EOL resistance:3.9K ohms. mal/short)of its Initiating Device Circuit(IDC). External supply voltage (between Terminals T3 and T4): NMM-100P(A) SPECIFICATIONS DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum.Current:90 mA per module maximum. Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 pA, 1 communication every Temperature range:32°F to 120°F(0°C to 49°C). 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Humidity range: 10%to 93%noncondensing. Shorted). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x Maximum IDC wiring resistance:40 ohms. Maximum IDC Voltage: 11 Volts. 2.125"(5.398 cm)deep box. Maximum IDC Current:400 pA. EOL resistance:47K ohms. Temperature range:32°F to 120°F(0°C to 49°C). Humidity range: 10%to 93%noncondensing. Page 2 of 4—DN-6999:C•10/06/2010 Notifier®and Fire Warden®are registered trademarks and FireWatchno is a trademark of Honeywell International Inc. ©2010 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. ISO 900 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. CERTF E o We cannot cover all specific applications or anticipate all requirements. FACINMMINC 11 AWMFACTIEINC All specifications are subject to change without notice. QUALITY SYSTEMS 1 ,11 For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. Made in the U.S.A. www.notifier.corn Page 4 of 4—DN-6999:C•10/06/2010 SYSTEM �. SENSOR® ,iiliiiiii : 4 , 1 1,1,111 f Indoor Selectable- Output Horns, " �. : # Strobes, �� and , a f ` Horn Strobes for Wall ApplicationsN System Sensor L-Series audible visible notification products are rich with features guaranteed to cut "" �'` '! installation times and maximize profits with lower current draw and modern aesthetics. ' Features • Updated Modern Aesthetics The System Sensor 4Series offers the most versatile and • Small profile devices for Horns and Horn Strobes easy-to-use line of horns,strobes,and horn strobes in the industry • Plug-in design with minimal intrusion into the back box with lower current draws and modern aesthetics.With white and red plastic housings,standard and compact devices,and plain,FIRE, • Tamper-resistant construction and FUEGO-printed devices,System Sensor L-Series can • Automatic selection of 12-or 24-volt operation at 15 and 30 meet virtually any application requirement. candela • The L-Series line of wall-mount horns,strobes,and horn strobes Field-selectable candela settings on wall units: 15,30,75,95, 110, 135,and 185 include a variety of features that increase their application versatility while simplifying installation.All devices feature plug-in designs • Horn rated at 88+dBA at 16 volts with minimal intrusion into the back box,making installations fast • Rotary switch for horn tone and two volume selections and foolproof while virtually eliminating costly and time-consuming • Mounting plate for all standard and all compact wall units ground faults. • Mounting plate shorting spring checks wiring continuity before To further simplify installation and protect devices from construction device installation damage,the L-Series utilizes a universal mountin • Electrically Compatible with legacy SpectrAlert and SpectAlertshorting p g 9 plate for all models with an onboard s rin so installers can test wiring Advance devices continuity before the device is installed. • Compatible with MDL3 sync module Installers can also easily adapt devices to a suit a wide range • Listed for wall mounting only of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch Agency Listings for horn tones with two volume selections. SIGNALING LISTED APPROVED ligillil L-Series Specifications Architect/Engineer Specifications General L-Series standard horns,strobes,and horn strobes shall mount to a standard 2 x 4 x 1 7/8-inch back box,4 x 4 x 11/2-inch back box,4-inch octagon back box,or double-gang back box.L-Series compact products shall mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuit'°Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95,110, 135,and 185. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21B-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1,2 Operating Voltage Range 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6"L x 4.7"W x 1.91"D(143 mm L x 119 mm W x 49 mm D) Compact Wall-Mount Dimensions(including lens) 5.26"L x 3.46"W x 1.91"D(133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.25"D(143 mm L x 119 mm W x 32 mm D) Compact Horn Dimensions 5.25"L x 3.45"W x 1.25"D(133mm L x 88mm W x 32mm D) 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts Candela DC 8-17.5 Volts 16-33 Volts DC FWR Sound Pattern dB DC DC FWR Candela 15 88 43 60 Temporal High 39 Range 30 143 63 83 g44 54 Temporal Low 28 32 54 75 N/A 107 136 Non-Temporal High 43 47 54 95 N/A 121 155 Non-Temporal Low 29 32 54 110 N/A 148 179 3.1 KHz Temporal High 39 41 54 135 N/A 172 209 3.1 KHz Temporal Low 29 32 54 185 N/A 222 257 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1 K Temporal High 93 156 53 73 119 140 164 190 242 3.1K Temporal Low 91 154 45 66 112 133 160 185 235 3.1K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1K Non-Temporal Low 93 156 52 72 119 138 162 192 242 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1K Temporal High 81 105 155 177 196 234 284 3.1K Temporal Low 68 90 145 166 186 222 276 3.1K Non-Temporal High 104 131 177 204 230 264 326 3.1K Non-Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data Horn and Horn Strobe Output(dBA) 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9* Coded High 85 90 90 10* 3.1 KHz Coded High 84 89 89 "Settings 9 and 10 are not available on the 2-wire horn strobes. L-Series Dimensions - - 1.91 3.46 = - --3.46 1.25 1.25 ii �_, 171 l _ ......„ III 5.27 ! lit „.„,:,„,, iii;t'iJiI: 5.27 L-Nj NQI 1111111111111II \`\�— �' .4 11111 Compact Strobe/Horn Strobe Compact Horn -.J---4.70 = 1.91 1.25 4.70 = � ri.-1------- 1.25 11 5.67 .1465611.. 'jill I� 67 lij 11 11;11h1 1 11 ,11 Strobe/Horn Strobe Horn L-Series Ordering Information Model Description Wall Horn Strobes Model Description Horns P2RL 2-Wire,Horn Strobe,Red HRL Horn,Red HWL Horn,White P2GRL 2-Wire,Compact Horn Strobe,Red P2GWL 2-Wire,Compact Horn Strobe,White HGRL Compact Horn,Red P2RL-P HGWL Compact Horn,White 2-Wire,Horn Strobe,Red,Plain Accessories P2WL-P 2-Wire,Horn Strobe,White,Plain P2RL-SP TR-2 Universal Wall Trim Ring Red 2-Wire,Horn Strobe,Red,FUEGO TR-2W Universal Wall Trim Ring White P2WL-SP 2-Wire,Horn Strobe,White,FUEGO Wall Strobes SBBRL Wall Surface Mount Back Box,Red SBBWL Wall Surface Mount Back Box,White SRL Strobe,Red SBBGRL Compact Wall Surface Mount Back Box,Red -J,” SBBGWL Compact Wall Surface Mount Back Box,White SGRL Compact Strobe,Red SGWL Compact Strobe,White SRL-P Strobe,Red,Plain SWL-P Strobe,White,Plain SRL-SP Strobe,Red,FUEGO SWL-CLR-ALERT Strobe,White,ALERT Notes: All-P models have a plain housing(no"FIRE"marking on cover) All-SP models have"FUEGO"marking on cover All-ALERT models have"ALERT"marking on cover �� SYSTEM 3825 Ohio Avenue•St.Charles, IL 60174 ©20or SENSOR Phone:800-SENSOR2•Fax:630-377-6495 pecifications subecct tolchaSystem ce withoutsnotice visits temsensorcom ® Products 1 g www.systemsensor.com or current product information,inclutling the latest version of his data sheet. AVDS86502•02/17 SYSTEM SENSOR® a. : Indoor Selectable- if sr" Output Strobes and Horn Strobes for Ceiling Applications ''',r• 7 . System Sensor L-Series audible visible notification • f 'A products are rich with featuresg uaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features The System Sensor L-Series offers the most versatile and • Plug-in design with minimal intrusion into the back box easy-to-use line of horns,strobes,and horn strobes in the industry • Tamper-resistant construction with lower current draws and modern aesthetics.With white and red plastic • Automatic selection of 12-or 24-volt operation LL-Sehousings, ries can meet virtually v rtuallly any ppliicationall and ceiling grequiirrement.ns, Sensor at 15 and 30 candela • Field-selectable candela settings on ceiling units: The entire L-Series product line of ceiling-mount strobes and horn strobes include a variety of features that increase their application • Horn rated at 88+dBA at 16 volts versatility while simplifying installation.All devices feature at plug-in 15,30,75,95, 115, 150,and 177 with minimal inuion into the back gn • Rotary switch for horn tone and two volume selections astland foolproof wh le virtually eliminating boxcostly and time-ins allations • Universal mounting plate for ceiling units consuming ground faults. • Mounting plate shorting spring feature checks wiring continuity To further simplify installation,the L-Series utilizes a universal before device installation mounting plate so installers can mount them to a wide array of back • Electrically Compatible with legacy SpectrAlert and SpectrAlert boxes.With an onboard shorting spring, installers can test wiring Advance devices continuity before the device is installed. • Compatible with MDL3 sync module • Listed for ceiling mounting only Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING 0 (0 LISTED APPROVED ISI 55512 FM approved except 7125-1653;0504 54011 for ALERT models 7135-16530503 3057383 L-Series Specifications Architect/Engineer Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box,4-inch octagon back box,or double- gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuit'm Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95, 115,150,and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Rangel 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range(MDL3) 8.5 to 17.5V(12 V nominal)or 16.5 to 33 V(24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6.8"diameter x 2.5"high(173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9"diameter x 3.4"high(175 mm diameter x 86 mm high) (SBBCRL,SBBCWL) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDS86800 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts Candela DC DC FWR 15 87 41 60 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1K Temporal High 111 164 69 94 147 163 184 229 257 3.1K Temporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1K Temporal High 108 135 179 200 225 255 289 3.1K Temporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data Horn and Horn Strobe Output(dBA) 8-17.5 16-33 Volts Volts Switch Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 AVDS86800 L-Series Dimensions 2.47 1.37 _ 06.83 0 6.92 2.50 1 a J•.rr.\,- I r/poo 0 4 iIII r-. : o og- 0 \..,_ i ! _.../ J Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box Or `") 1/ - * 4.5--- o , `jpJ �,pcek., ,Z3;;;71-1-4'r j:-;');.11!':',. 1��it1717._' I) a ,,,;,:.,..,,,,,.._ __,N _ ....,.. , . 1 . „,,.... . ,,,, . . .. .. , ...,,,-.: __. , �t`i1® Yi,.. I 1 Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box L-Series Ordering Information Model Description Model Description Ceiling Horn Strobes Ceiling Strobes PC2RL 2-Wire,Horn Strobe,Red SCRL Strobe,Red PC2WL 2-Wire,Horn Strobe,White .,:+>iet ,R SCWL-CLR-ALERT Strobe,White,ALERT Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box,Red SBBCWL Ceiling Surface Mount Back Box,White SYSTEM ©2017 System Sensor. 3825 Ohio Avenue•St.Charles, IL 60174 Product specifications subject to change without notice.Visit systemsensorcom SENSOR® Phone:800-SENSOR2•Fax:630-377-6495 for current product information•including the latest version of this data sheet. AVDS86801•03/17