Loading...
Plans (54) - OFFICE COPY ,t,."a' .1. , ,4) PROJECT INFORMATION NUMBER OF ARRAYS PROPOSED: 4 ARRAY#1 DETAILS #OF MODULES:21 TILT:17° AZIMUTH:90° OWNER SHERMAN RESIDENCE CONTRACTOR SUNBRIDGE SOLAR 15352 SW OAKMONT PL,TIGARD,OR 97224 706 W 17th St ARRAY#2 DETAILS #OF MODULES:9 TILT:17° AZIMUTH:270° VANCOUNVER,WA 98660 ARRAY#3 DETAILS #OF MODULES:6 TILT:33° AZIMUTH:180° BUILDING SINGLE FAMILY CONTACT:JORDAN WEISMAN DATA RESIDENTIAL PHONE:503-407-6820 ARRAY#4 DETAILS #OF MODULES:6 TILT:33° AZIMUTH:180° APPLICABLE 2014 OREGON STRUCTURAL CODE(SECTION ROOF SPECS COMPOSITE SHINGLE ROOFING 2X4 CODES 3111) PRE-ENGINEERED MANUFACTURING TRUSSES 3'ROOF SETBACK @ 24"O.C.,DOUGLAS FIR#2(TRUE DIMENSION) SYSTEM SOLARWORLD SW 300 MONO SOLAR TILT:33°AND 17° _______ MODULES AZIMUTH:90°,180°,AND 270° (S) -----_- (42)X300W=12.60 KWdc @ STC AREA OF ROOF(PLAN VIEW).3,338 SF (N)ARRAY 2 (42)IQ6-60-2-US MICRO INVERTERS AREA OF NEW ARRAY(S)=680 SF(ARRAY<20% I o 1 p p p 0 0 OF ROOF AREA) I -- ❑ 00 • o 1 MODULE SOLARWORLD SW 300 MONO SITE DETAILS CLIMATE DATA SOURCE: I 1 •❑ ° 1 SPECS (L)65.94"X(W)39.37"X(H)1.30" I � 1 WEIGHT=39.7 LBS PORTLAND/HILLSBORO,OR,USA,45.53N, COMBINED WEIGHT OF 122.95W ,' 1 MODULES AND RACKING 5 4.5 PSF ASHRAE EXTREME LOW:-8.4°C 1 ' ;ii 1 ASHRAE 2%HIGH:36°C ✓ _ WIND SPEED:110 MPH(ASCE7-10) RISK CATEGORY:II ❑ WIND EXPOSURE CATEGORY:B a I DRIVEWAY ❑❑ GROUND SNOW LOAD:10 PSF :- PROJECT NOTES o I (N)ARRAY 1 1. PV SYSTEMS AND SUPPORTING STRUCTURE SHALL COMPLY 1 ❑ (N)ARRAY 3 1 WITH REQUIREMENTS OF 2014 OREGON STRUCTURAL CODE STRUCTURE,A MAINTAINED ALONGUM O1UNOBSTRUCTEDSIDOFANY HORIZONTALRIZON L� 1 -- (SECTION 3111). SHALL BE EACH SIDE OF _ RIDGE. j\\ 2. 3111.3.2-PV RACKING AND ATTACHMENTS SHALL BE UL 1703 EXCEPTION 1.2:WHERE THE SOLAR ARRAY EXCEEDS \ (N)ARRAY 4 CERTIFIED. 25%AS MEASURED IN PLAN VIEW OF TOTAL ROOF AREA OF THE STRUCTURE,A MINIMUM OF ONE 36" (E)METER,(E)PANEL, 3. 3111.3.4-PV SYSTEM SHALL HAVE A FIRE CLASSIFICATION THAT (N)AC PV DISCONNECT, IS EQUAL TO OR GREATER THAN THE ROOF ASSEMBLY 6. ROOF STRUCTURE IS CONVENTIONAL LIGHT FRAMED WOOD (N)AC IQ ENVOY REQUIRED BY OSSC SECTION 1505.1. CONSTRUCTION WITH PRE-ENGINEERED MANUFACTURING - N TRUSSES @ 24"O.C.REFER TO ALLOWABLE SPAN (E)RESIDENCE 4. 3111.4.3-3111.4.7-PV LAYOUT SHALL NOT RESTRICT EGRESS, REQUIREMENTS IN TABLE 305.4.1. LIGHT VENTILATION,OR ROOF DRAINAGE REQUIREMENTS. S ��i K WITH CITY/COUNTY OR LAND 7. 3111.4.8.5.1-DISCONNECTS,J-BOXES,COMBINER BOXES OR YOR FO OCATE. 5. 3111.4.8.1-GENERAL PATHWAY REQUIREMENTS:ALL PV GUTTERS SHALL NOT BE PLACED IN ANY REQUIRED PATH' MEWED OR CODE CO � INSTALLATIONS SHALL INCLUDE A 36 INCH WIDE PATHWAY OR CUTOUT. MAINTAINED ALONG THREE SIDES OF THE SOLAR ROOF. 8. 3111.5.3.1-TOTAL SYSTEM WEIGHT SHALL NOT EXCEED 4. proved:\141 DRAWING LIST EXCEPTION 1:ON STRUCTURES WITH A PV ARRAY AREA OF 1,000 PV MODULES AND RACKING SHALL BE DIRECTLY ATTACHED • SF OR LESS INSTALLED ON A ROOF WITH A SLOPE THAT ROOF FRAMING AS SHOWN IN PV-2.ATTACHMENT SPACINe V''I C: i , • PVI:TITLE SHEET EXCEEDS 2:12 AND WITH AN INTERSECTING ADJACENT ROOF BE 48"O.C.MAX,AND WHEN ATTACHMENT LOCATED WITHIN 3' PV-2:FRAMING PLAN AND WHERE NO SECTION IS LARGER THAN 150 FEET MEASURED OF ROOF EDGE,HIP,EAVE,RIDGE SHALL BE 24"O.C.MAX. IN LENGTH OR WIDTH. Permit#: PV-3:ROOF PLAN EXCEPTION 1.1:WHERE PV ARRAY DOES NOT EXCEED 25%AS 9' 3111.5.4-MAX MODULE HEIGHT<18"OFF ROOF SURFACE. i PV-4:THREE LINE DIAGRAM MEASURED IN PLAN VIEW OF TOTAL ROOF AREA OF A Address: J��-3 _t... O a r.,40 re pc__PV-5:LABELS Suite�{: APPENDIX:DATA SHEETS CONTRACTOR •7 # - 8 SUNBRIDGE SOLAR € SHERMAN RESIDENCE By: . Date: PV SITF PI AN 706 W 17th St 5u l,,,,S Residential Grid Interactive Solar Installation System AC Size @ STC:10.08 kW System DC Size @ STC:12.60 kW Page: VANCOUNVER,WA 98660 S 0 L A R 15352 SW OAKMONT PL,TIGARD,OR 97224 (42)SOLARWORLD SW 300 MONO SOLAR MODULES Ph:503-407-6820 Ph: (42)106-60-2-US MICRO INVERTERS Contractor#198787DA PV-1 by: Drawn Date: Rev:Perm%Set 3/8/2018 LOW PROFILE ROOF SEE MOUNTING DETAIL PROTRUSION,TYP. IRONRIDGE XR10O RAIL& FLASH FOOT 2 ❑ ❑ ❑ 000 \- " i ,..4 41. SOLARWORL. ❑❑ `©j © SW 300 MONO MODULE i/ 00 1 io 0 %%__ _ ' 2X4 TRUSS @ 24"O.C. ii=_ ___ N FRAMINGSCROSS SECTION 17° (-- 0 : /4 5 --- ESOLARWORLD SW 300 MONO SOLARWORLD 300 M NO I SW 300 MONO A❑ --- MODULE 1 --- MODULE I I 1 I I ©I 1 I I 1 1 1 ____ -__LIRONRIDGE 2X4 TRUSS y L 17° _ �y1 / XR100 RAIL @ 24"O.C. I t // V ! I I I 33° USE 4" IRONRIDGE i� ��- IRONRIDGE 4" STANDOFF ON XR1O0 RAIL Z0 0 3'SETBACK 4, �,� _. _ Ili FLASH FOO `�`` ``` \_` �\ THIS ARRAY 'y FLASH FOOT 2 STANDOFF COMPOSITE O U SHINGLE 4.33° 410 SCREWS LAG WIT ROOFING /16"x3"LAG Fi SCREWS WIT 0 LEGEND: 2.5"MIN. ii•� 2.5"MIN. N 19'-3r' Q FLASH FOOT /r EMBEDMENT �� EMBEDMENT SPAN 24"TO MEET \ I ASCE 7-10 WITH WIND OMPOSITE \ _ 2X4 TRUSS SPEED AT 110 MPH I SHINGLE 2X4 TR I @ 24"O.C. W E Q FLASH FOOT 2 L ROOFING O.0 J FRAMING PLAN 2 SPAN-4FT.TO MEET S SCALE:1/8•=1'-0" SASCE 7-10 ITH PEED AT11OMPHIND MOUNTING DETAIL MOUNTING DETAIL WITH STANDOFF SCALE N.T.S. SCALE N.T.S. CONTRACTOR SUNBRIDGE SOLAR SHERMAN RESIDENCE FRAMING PLAN 706 W 17th St i r Sun h ^ r':' Residential Grid Interactive Solar Installation System AC Size @ STC:10.08 kW System DC Size @ STC:12.60 kW Page: VANCOUNVER,WA 98660 . 5 0 L A R 15352 SW OAKMONT PL,TIGARD,OR 97224 (42)SOLARWORLD SW 300 MONO SOLAR MODULES (42)106-60-2-US MICRO INVERTERS Contractor#198787 PV-2 Ph:503-407-6820 Ph: Drawn by: Date: OA Rev:Permit Set 3/1/2018 GENERAL NOTES. A. CONDUIT IS DIAGRAMMATIC.FINAL ROUTING TO BE 3'SETBACK DETERMINED BV INSTALLER. T B. SUNE SHOTS WERE COLLECTED IN THE ❑ I ❑ ❑ ❑ ❑ EI B. EV SPECIFIED LOCATIONS. [1E[] ❑ o ROOF RIDGE ❑❑ i _ , , ■ • Ell 1: . El /,,e NIZ 41 Ei Z o cm \ ■ U ■ • m m ❑ ❑ Lim ■ /�n �• -� •4m I • ROOF EAVE 3/4"EMT `` `� SOLARWORLD SW 300 MONO MODULE -. • • • ■ ■ --) I I06-60-2-US MICRO INVERTERS ARE I BRANCH#4(12 MODS) LOCATED UNDERSIDE OF EACH cv I — MODULES AND ARE INSTALLED TO 1"EMT--) El El al CONTINUOUS SUPPORT RAIL. I Si, J (E)PANEL / 29'-9" (INTERIOR WALL) N (E)METER (N)IQ ENVOY (EXTERIOR WALL) (EXTERIOR WALL) W E ROOF PLAN FUSED AC DISCONNECT SCALE:1/8"=1'-0" (EXTERIOR WALL) S CONTRACTOR SUNBRIDGE SOLAR l SHERMAN RESIDENCE ROOF PLAN 706 W 17th St Su n br)1 I'1Residential Grid Interactive Solar Installation System AC Size W STC:10.08 kW System DC Size W SIC:12.60 kW Page: VANCOUNVER,WA 98660 --S 0 LAR ' 15352 SW OAKMONT PL,TIGARD,OR 97224 (42)SOLARWORLD SW 300 MONO SOLAR MODULES Ph:503-407-6820 Ph: Contractor#198787 (42)106-65-2-us MICRO INVERTERS PV-3 Drawn by: Date: DA Rev:Permit Set 3/12018 - I METER JUNCTION BOX(TVP.) GENERAL NOTES: A. CONTRACTOR RESPONSIBLE FOR COMPLYING WITH e3/4"CONDUIT:— ENPHASE 0 CABLE(TVPJ ALL LOCAL OR NATIONAL CODE REQUIREMENTS AND °(2)#10 AWG THWN-2 CONDUCTORS BLACK-L1 EQUIPMENT INSTALLATION INSTRUCTIONS. SUPPLY-SIDE (1)#10 AWG THWN-2 GROUND CONNECTION RED-L2 PER NEC B. SEE PV-5 FOR LABELING REQUIREMENTS ARTICLE 690.64 EXISTING 1205/ BRANCH CIRCUIT#4 C D ))1 OUTLET / / (12)SOLARWORLD SW 300 (\ <\ • • • ' MONO MODULES S C ' (12)MICRO-INVERTERS PATCH CABLE TO I I I I I I • I. 2405/VAC _ NETWORK ROUTER �10 ENVOI I B LOCKABLE,FUSED ac 80A {J ti 1O © LAY IN LUG • DISCONNECT - 15ARAIL 4 ENPHASE 106-60-2-US 90A,2405/,2-POLE �t�tl • NEUTRAL ....... /...... 1 / / / /I BRANCH CIRCUIT#3 (\\\ /\ `/\ • • • (a)SMONO O DU SWES 300 MONO MODULES caoue0 O O (9)MICRO4NVERTERS 00 S GUN I I I I I 11 • 5 240V VAC EXISTING AC DISTRIBUTION PANEL — IMI 120/240V,10.3W BOA IG ENVOY, 200A PANEL NEMA-3R,120/2405/,I 20UA MAIN BREAKER 3/4'EMT OR EQUIVALENT: ,\., © LAY IN LUG (2)#6 AWG THWN-2 CONDUCTORS (1)#10AWG THWN-2 GROUND L I ,1 I, RAIL '1'CONDUIT: IA (( ENPHASE 116-60-2-US (e)#10 AWG THWN-2 CONDUCTORS ....._. ..._.. .._.. ...... ........ J_. .... II (4)#10 AWG THWN-2 GROUND 3/4"CONDUIT (2)#10 AWG THWN-2 CONDUCTORS° MODULE SPECS INVERTER SPECS (1)#1D AWG THWN-z GROUND BOR-ET RM TOE(NP TOR MAX.POWER Pmax 300 W MAX.POWER Pmax 240 W / / / BRANCH CIRCUIT#2 OPEN CIRCUIT VOLTAGE Voc 40.1 V MAX.INPUT VOLTAGE 48 V (\ ` ( • • • �I (10)SOLARWORLD TE 300 \ \\\\ MONO MODULES OWER POINT Vmp 31.5 A Voc @-8.4°C 44.1 V • (10)MICRO-INVERTERS SHORT CIRCUIT CURRENT Iso 10.23 A 44.1V<48V YES I I I I I I @ 240V VAC MAX.POWER POINT Imp 9.57 A OUTPUT CURRENT 0,96 A — _ _ Voc TEMP.COEFF. -0.30%/°C OUTPUT VOLTAGE 240 V,1¢ ti '\./ © ILIN LUG RA li 11 Pmax TEMP.COEFF. -0.42%/°C DC/AC RATIO 1.25 III III S ENPHASE 106-604-USli VOLTAGE DROP CALCULATIONS L 3/4"CONDUIT, -- _. .... WIRE RUN #OF MODS V(VOLTS) I(AMPS) L(FT) VD VD(%) WIRE SIZE RACEWAY (2)#10 AWG THWN-2 CONDUCTORS° (1)#10 AWG THWN-2 GROUND #6 BARE CU(TYP.) BRANCH 1 11 2405/ 10.54A 72 1.64V 0.68% 12 AWG O CABLE FREE AIR BRANCH 2 10 24051 9.58A ' 66 1.37V 0.57% 12 AWG O CABLE FREE AIR BRANCH 3 9 240V 8.63A 59 1,12V 0.47% 12 AWG 0 CABLE FREE AIR / / / BRANCH CIRCUIT#1 BRANCH 4 12 240V 11.5,5 79 1.94V 0.81% 12 AWG O CABLE FREE AIR S. S. < • • • �I (11)SOLARWORLD SW 300 BRANCH 1 HOMERUN 11 240V 10.54,5 58 1.52V 0.63% 10 AWG THWN-2 3/4"EMT \ MONO MODULES BRANCH2HOMERUN 10 240V 9.58A 64 1.525/ 0.63% 10 AWG THWN•2 3/4"EMT k (11)MICRO-INVERTERS I I 1 1 • 5 240V VAC BRANCH 3 HOMERUN 9 2400/ 8.63,5 48 1.03V 0.43% 10 AWG THWN-2 3/4"EMT — II BRANCH 4 HOMERUN 12 240V 11.5A 36 1.03V 0.43% 10 AWG THWN-2 3/4"EMT ^, ^, ti RAI IN LUG MI IO ENVOY 42 240V 40.32A 10 0.40V 0.16% 6 AWG THWN-2 3/4"EMT RAIL " > to to ENPHASE 106-60-2-US MAX VOLTAGE DROP:1.48% I a , —s. II CALCULATIONS NOTES:'WIRE SIZES INCLUDE DE-RATING FACTORS SUCH AS AMBIENT TEMPERATURE AND MORE THAN 3 `3/4'CONDUIT: - - CURRENT CARRYING CONDUCTORS IN CONDUIT.UP TO 3 BRANCHES IN).CONDUIT AND UP TO 5 BRANCHES IN 1"CONDUIT. (2)#10 AWG THWN-2 CONDUCTORS® 1) V. CONTRACTOR #10 AWG THWN-2 GROUND #6 BARE CU(TVP.) SUNBRIDGE '' SHERMAN RESIDENCE THREE LINE DIAGRAM 706 W 17th St 1 Sun E 1 I'. Residential Grid Interactive Solar Installation System AC Size @STC:10.08 kW System DC Size @STC:12.60 kW Page: VANCOUNVER,WA 98660 SOLA R 15352 SW OAKMONT PL,TIGARD,OR 97224 (42)SOLARWORLD SW 300 MONO SOLAR MODULES (42)106-60-2-US MICRO INVERTERS PV-4 Ph:503-407-6820 Ph: Contractor#198787 Drawn by: Date: DA Rev:Permit Set 3/12018 OWARNING-PHOTOVOLTAIC PHOTOVOLTAIC SYSTEM NEC 2017 690.12,690.56(0(1)(a) CAUTION A POWER SOURCE AC DISCONNECT SOLAR PV SYSTEM EQUIPPED S LABEL EVERY IO' - OPERATING AMPSOLT40.32A WITH RAPID SHUTDOWN POWER TO THIS BUILD NG ISNPUT SUPPLIEDED FROM THE OOPERATING VOLTAGE 240V M FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS O I CAUTION SOLAR CIRCUIT ® WARNING ® SHOWN: ELECTRIC SHOCK HAZARD TURN RAPID SHUTDOWN LABEL EVERY 10' DO NOT TOUCH TERMINALSSWITCH TO THE"OFF" POSITION TO SHUT DOWN P 17.:,::1,1-7.: 'OSOLAR ARRAYS TERMINALS ON BOTH LINE ANDPV SYSTEM AND REDUCELOAD SIDE MAY BE ENERGIZED IN SHOCK HAZARD IN THE LCAUTION:SOLAR ELECTRICSYSTEM CONNECTED 711,1 0THE OPEN POSITIONARRAY /-- O -•� C LOCATION:MAIN AC DISCONNECT RAPID SHUTDOWN I1 — LOCATION:MAIN SERVICE PANEL LABEL FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND THE CONDUCTORS LEAVING THE ARRAY. A WARNING A NOTE: THE LABEL SHALL UTILIZE CAPITALIZED SERVICE J PV AC CHARACTERS WITH A MINIMUM HEIGHT OF 3/8"IN BLACK DISCONNECT DISCONNECT UAL POWER SUPPLY O SOURCES:UTILITY GRID AND CHARACTERSCN YELLOW BACKGROUND,AND THE REMAINING SHALL BE CAPITALIZED WITH AMINIMUM SOLAR PHOTOVOLTAIC SYSTEM HEIGHT OF 3/16"IN BLACK ON WHITE BACKGROUND. m WARNING m LOCATION:MAIN SERVICE PANEL ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION LOCATION:BUILDING MAIN SERVICE PANEL CONTRACTOR SUNBRIDGE SOLAR g SHERMAN RESIDENCE LABELS 706 W 17th St S LI n 1. 1 r C :'' Residential Grid Interactive Solar Installation System AC Size @ STC:10.08 kW System DC Size @ STC:12.60 kW Page: VANCOUNVER,WA 98660 5 O L A R 15352 SW OAKMONT PL,TIGARD,OR 97224 (42)SOLARWORLD SW 300 MONO SOLAR MODULES Ph:503-407-6820 Ph: (42)106-60-2-US MICRO INVERTERS PV-5 Contractor#198787 Drawn by: Date: DA Rev:Permit Set 3/1/2018 b Sunmodule/Plus i -� r SW 185OO�MONO -= PERFORMANCE UNDER STANDARD TEST CONDITIONS(STC)° SW 285 SW 290 SW 295 SW 300 TUV Power controlled: v�a$aa m p Maximum power P,,,, 285 Wp 290Wp 295 Wp 300Wp Lowest measuring tolerance in industry mwp=--"'" E Open tircu(t voltage V.1011 39.7 V 39.9 V 400 V 401 V Moo oer power point voltage V,,,,, 313 V 314V 31.5V 31.6V t Short nrcuk toren I„ 9.84A 9.97A 10.10 A 10.23 A Maximum power point current I„w 9200 9.33A 9.45A 9570 Every component is tested to meet Moduleeffidemy n, 17.00% 17.30% 17.59% 17.89% 3 times IEC requirements a O "MG3000W/m',25 T.AM Ls PERFORMANCE AT 800 W/Ma,NOCT,AM 1.5 • - SW 285 SW 290 SW 295 SW 300 Designed to withstand heavy Maximum power P,,,,, 2131 Wp 217.1 Wp 220.5 Wp 36.7V 2241 Wp accumulations of snow and ice Open circuit voltage VV„, 364V 36.bV 36.9V O Maximum power point voltage V, 287 V 28.8 V 28.9 V 311 V s ri q Sheet circuit current I, 796A 806A 817A 8270 Maximum power point current I,,,e, 7.430 7.540 7.640 7.750 Sunmodule Plus: Minorrmnevnir etc en<yunder padianoaa Bond non:atzs•c.,izoow/mr,lo0%oftne stc eebdency 6000 w/011,5arn;exed. Positive performance tolerance COMPONENT MATERIALS I. 1000 W/n>' 11111 i._„ ---- Cells p„module 60 Fant Low-iron tempered glass with ARC(EN 12150) 25-year linear performance warranty L........44...".........06.............H.- Monocr staliineii 1 s 600 w/m� Ce//rype S 617 iifame Clear anodlxd aluminum and 10-year product warranty O 6.17;6x6.171) We/hf39.7lbs 18.0kIMI"' Cel/dimensions (156.75 x156.75 mm) 9 ( 81 THERMAL CHARACTERISTICS ADDITIONAL DATA ,gt.. Glass with anti-reflective coating NORP P 46-C POWersolH 1 -0W/t5W• Owawe.ae,eaM V°` TCI. 004%/°C 7-Box IP65 378 961) ,,_ _ — -030 Connector - World-class quality ,�..ara.ncaa,r - - i o© - -- - --- c anrm connector: TCV % 0/ AIL s•• 'aaaa.�sc aro (1116.'6'5)_ Fully-automated production lines and seamless monitoring :naa.a'•.a�an.,.•.xraooa.a.aa ��® = ax-±- Operating temp -40 to es PV wire per UL47o3 H4/UTX ,C Moduleflre perm (UL 7703)Type1 of the process and :.m�•w�,•.•.n,K 6. p o.z6 16 6) material ensure the quality that the company sets as its benchmark for its sites :"'nnmiM,p:�„”;iFf1°' c_us 080.85) PARAMETERS FOR OPTIMAL SYSTEM INTEGRATION worldwide. Q UL 1703 ••0.5(9) Plus-Sorting guaranteesgab. g an1dr „i• Ma system voltage SC 11/NEC SolarWaldPlus-Sortin Iso9ool Ma w c rent loo v efficiency. p y mo laedl __ 250 that have greater than orequal to the nameplate rated SolarWorld only delivers modules %.% Ina,x,kkm 'ti"`I °i _ Na be firyp - - - 3 highesty " .os•.,..r,.,,,.° Design loads' twoaosystese 113 psf downward,64 fu d Ps pwar 2S-year linear performance guarantee and extension of product warranty tom°year it.- is a Design loads _Three raiisystem 176 psf downward,64 psf upward SolarWorld guarantees a maximum performance digression of 0.7%p.a.in the course - --- .- of25yea rs,a significant added value compared to the two-phase warranties common Design Mods' Edge mounting178 psf downward,47 psf upward in the industry,along with our industry-first 70-year product warranty." 'Vlease refertothe Sunmoaule installation instr«tioreforthe details as:«latee weh these mai cases. Solar cells manufactured in U.S.A.or Germany.Modules assembled in U.S.A. '•■ h-l1 .Compatible with both"Top-Down" 1 ";n accordance with the applicable SolarWorld Limited Warranty at purchase. •k1o35(9i and"Bottom"mounting methods wwwsolarwodd.r6m/warranty /.■■■ r 11'32 I �'� • Grounding Location s: (28150) I..■.■■, wnn -41«ations along the length of the - I - IL module in the extended flange. 394(1001) II • solarworid.com 1.301331 Acunitsprsaded areimperial.sl units provieed isparentheses. I.—'alal—..1 SolarWorld AG reserves the dghttomake spe[rtcation changes without notice. 5W-01-7 510 0 5 161006 Data Sheet Enphase Microinverters Enphase IQ 6 and IQ 6+Microinverters INPUT DATA(DC) IQ6-60-2-US/1Q6-60-5-Us IQ6PLU3-72-2-US I IQ6PLUS-72-5-US CommOptyused Module paIdnga' 195:W-330W+: 235W-433w+ 1 Module compatibility 60-cell PV moiules only 60-cell and 72-cell PV modules Mexlm9Mtnput DC vcllage 48V 42 V f Peak power tracking voltage 27 V-37 V 27 V 45 V Enphase The high powered smart grid ready °perettilyiadon 16V--48Y 16V-62V Enphase IQ 6 Micro"and Enphase IQ 6+Micro" Mtn/Max start voltage 22 V/49 V 22 V/62 V 3dsx0Cslutrt¢kdtifld t.OluNbOtc) - 45A 157. . ) IQ 6 and IQ 6+ dramatically simplify the installation process while overvoltageclass ocport II II achieving the highest efficiency for module-level aC oiNlOsgite lu slag fault .. - QA . `. .- . DA -. M i c ro i nve rte rs power electronics. PV array configuration 1 x l ungrounded array;No additional DC side protection required; AC side protec tion requires max 20A per branch circuit Part of the Enphase IQ System,the IQ 6 and OUTPUT DATA(AC) 14 6 Microlnverter IQ 6+Microinverter IQ 6+Micro integrate seamlessly with the Enphase PebkotdputpQwen 249 VA 2gOyA Maximum continuous output power 230 VA - IQ Envoy"',Enphase Q Aggregator',Enphase IQ NNominal , 24VA OA.) 2,urvt2tt' 1�r: 208313 VT -929 24 0 vraat-a64v -MI/016229Y. Battery',and the Enphase Enlighten"'monitoring Maximum continuous outputcurcent 0.960 1.11 A 1.17 A 1.35A and analysis software. $ominat fsegaenc rutrr' OP lit Extended frequency range 47-68 Hz 47-68 Hz The IQ 6 and IQ 6+Micro extend the reliability P000rtafdoratretedpmaer 1-f) 1.0 . Maximum units per 20 A(L-1)branch circuit 16(240 VAC) 13(zoo vac) standards set forth by previous generations and undergo over a million hours of power-on testing, 14(209 vac) 11(208 VAC) tWarvoltageolaatAepurt .111 01. x enabling Enphase to provide an industry-leading AC port backfeed under single fault 0 A 0 A warranty of up to 25 years. Powerfootor(ed)uatatoe) ;' O,7 reading...O.7lagglog. O.7 leading,,,O.7l000log j EFFICIENCY ---- X240 V @208 V (,4240 V @203 V - CCC weighted:effctency 970%59'/0%': 970% = :970%1. MECHANICAL DATA Easytolnstall Amblemtemperaturerange 40°C to+65°C •Lightweight and simple Relative humidity range 4%to 100%(condensing) •Faster installation with improved two-wire cabling Connector type MC4(-2-US)Or Amphenol H4UTX(-S-US) •Built-in rapid shutdown compliant(NEC 2014&2017) Dimensions(WnHsD) 219 mm x 191 mm x 37.9 mm(without bracket) Weight 1.5 kg 0.3 Os) Cooling Natural convection-No fans - Productive and Reliable Appronedfor wetlocations Yes - Pollution degree PD3 •Optimized for high powered 60-cell and Enclosure'. Class II double-insulated 72-cell*modules Environmental category/UV exposure rating Outdoor-NEMA 250,type 6(IP67) •More than a million hours of testing FEATURES •Class IIdouble-insulated enclosure Communication Power line •UL listed Monitoring Enlighten Manager and MyEnlighten monitoring options Compatible with Enphase IQ Envoy Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as th9 bad-break Smart Grid Ready disconnect required by NEC 690. •Complies with fixed power factor,voltage and Compliance CA Rule 21(UL 1741-SA) frequency ride-through requirements UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class 9,ICES-0003 Class B, CAN/CSA-C22.2 NQ.107.1-01 •Remotely updates to respond to changing This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and grid requirements NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC •Configurable for varying grid profiles and DC conductors,when installed according manufacturer's instructions. U •Meets CA Rule 21(UL 1741-SA) 1.No enforced DC/AC ratio.See the compatibility calculator at enphvse,cnm/en-iis/su000rt/module-comoatibility. L 2.Nominal voltage range can be extended beyond nominal if required by the utility. *The IQ be Micro is required to support 72-cell modules To learn more about Enphase offerings,visit enphase.com To learn more about Enphase offerings,visit enphase.eom n EN PI-IAS E. 20'7 Enphase Energy All nights eserved.nil trademarks or brands used arethe property or Enphase Energy,inc. EN P HAS E. 2017-09-ii Data Sheet Enphase Networking Enphase IQ Combiner+ MODEL NUMBER 100etebl XIQ-AMI-240-2 IO:Combiner,wihenphase iti Envcr for integreteit icy/onus gradetti orouttionmetering k (ANSICt2.20+f,-Us%)anti optlonal+consumption monitoring(+1.2, - ACCESSORIES(order separately) Enphase The Enphase IQ Combiner+'"with Enphase EnphaseMobieConnect Plug and playindustrtalgradecellulardem with a for up CELLMODEM-03(40/12-yearyd W) mlcrotn ,(Avaiable in the US C6 *higxi(o Puerto Rico, i US 114ti IQ Combiner+ IQEnvoy'consolidates interconnection CEO.640461Q1(30/5-years p n); Where-theme)sadequate cellular service in the 108faiternureao equipment into a single enclosure and in Monitoring CT SplitcarecurrentVensformersenablewholehomeconsumptionmetering�(+/-2.5%). CT-200-SPLIT X-IQ-AM1-240-2) streamlines PV and storage installations by ELECTRICAL SPECIFICATIONS providing a consistent,pre-wired solution for System voltage 240 VAC,60 HZ residential applications.It offers up to four FatoeBB: h(esbusbarrai - 125A 2-pole input circuits and Eaton BR series Max.continuous current rating(output to grid) 65A busbar assembly. Max.fuselteeekrating(output) - ggA Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DG)breakers only(not included) Max.continuous currentr g(lnputfrooltIV) 64A r .. Max total branch circuit breaker rating(input) 80 A(any combination) Production Metering CI 200 A solid core Installed and weed to 1.0feey. MECHANICAL DATA Dimeoilons(WxHxD) 443x 46,51(.14.00r(19.4*x18,8*1(6.3") �. Smart Weight 7.5 kg(16.5 lbs) .i`,' Includes lO Envoy for communication Ambient temperature r0nge 40o C10+46"C(at0"to 115°F) and control Cooling Natural convection,plus heat shield ,;.,-'-- -- •Flexible networking supports Wi-Fi, Enclosure environmental rating Outdoor,NRTLcertified,NEMA type 3R,polycarbonate construction '.; ¢ • Ethernet,or cellular -- - .: Wire sizes •20 A to 50 A breaker inputs:14 to 4 AWG copper conductors •Provides production metering and optional •60 A breaker branch input B to 1/0 AWG copper conductors consumption monitoring •Main lug combined output 6 to 2/0 AWG copper conductors S• - •Supports installation of the •Neutral end ground:14 to i/0 copper conductors {•;;` Enphase 0 Aggregator" Always follow local code requirements for conductor sizing. . a •1 Altitude To 2000 meters(6,560 feet) INTERNET CONNECTION OPTIONS f<< q Simple Integrated Wi-Fi 802,116/g/n !x '?: • Eaton BR series panelboard interior Ethernet 802.3,CatbE(or Cat 6)UTP Ethernet cable-not included •Up toifour 2-pole branch circuits for 240 VAC Cellular Optional,CELLMODEM-01.(3G)or CELLMODEM-03(4G)(not included) plug-n breakers(not included) COMPLIANCE I 80 A total PV or storage branch circuits - 'c Compliance,Combiner UL 1741 CAN/CSA C22.2 No.107.1 47 CFR,Part 15,Class B,ICES 003 Reliable Production metering:ANSI C12.20 accuracy class 0.5(PV production) • Durable NRTL-certified NEMA type Compliance,IQ Envoy UL 916 3R enclosure CAN/CSA 022.2 No.61010-1 • Five-year warranty •UL listed *Consumption monitoring is required for Enphase Storage Systems. CZ!' LISTED To learn more about Enphase offerings,visit enphase.com To learn more about Enphase offerings,visit enphase.com a ENP HAS E, ®zoi 7 Enphase Ene gy All rights reserves All trademarks or brands in this docurvem are registered y[heir respect a owner. \moi E N PHAS E. 2017-70-26