Plans (26) SITE PLAN-HEATHER ROMANO z m - < > CD - Ca 0Z Lii Lu _ (5 CO D• TO Q U 3 Z W Z Q M ..1 Ce 00 IZ U OFFICE COPY D 4 TO CITY OF TIGARD 0 AC DISCONNECT R VI OWED FOR CODE COMPLIANCE INVERTER Apnrcved: �] AC DISCONNECT OTC: METER- INTERCONNECTION Pe•mit #: y,r, "']1p.� Ackiress: 7 9 7 -7 C r._r 0 L an» Su te#: By. _ 9 ) Dates - ) S- j4i SYSTEM SIZE= 7.37 KW/SYSTEM AREA=400'SQ >25% SOLAR OWNER: BUILDING APPLICABLE ROOF SPECS: SYSTEM INFO: ENERGY CONTRACTOR: DATA: CODES: Solutions ENERGY SOLUTIONS LLC HEATHER ROMANO 1-2 FAMILY 2017 OREGON COMPOSITION/ 4 NGIN RU SES ROOF FRAMED MODULES-)LG335N1C-A5 QUALIFY BLACK FOR ETO v► PO BOX 887 7977 SW CAROL ANN CT SINGLE RES. STRUCTURAL DOUGLAS FIR#2 @ 24"ON (10)LG335N1C-A5 WATT MONO BLACK BEAVERCREEK,OR 97004 TIGARD OR 97224 INSTALLATION CENTER z 503.680.3718 224.430.9389 SPECIALTY FRAMED MODULES DO NOT QUALIFY ..`» CCB#202002 ROOF AREA=1260'SQ FOR ETO r CODE TILT=30 DEGREES (1)SOLAREDGE 7600H-US INVERTER AZ= 270&90 DEGREES (22)SOLAREDGE P370 DC OPTIMIZERS W/ 2017 NEC CODES LOWEST READING=76%TSR ZIGBEE MONITORING 3111.4.8.1 General Pathway Requirements.All PV installations shall include a 36 inch wide(914mm) 3111.4.8.4 Smoke and Heat Vents.In structures where smoke and heat vents have been installed to pathway maintained along three sides of the solar roof.The bottom edge of a roof with a slope that comply with the requirements of the Fire Code,Chapter 9 Smoke and Heat Vents and Chapter 32 High exceeds 2:12 shall not be used as a pathway.All pathways shall be located over a structurally supported Piled Storage,a 36 inch(914mm)wide pathway to and around each vent shall be provided for fire area and measured from edge of the roof and horizontal ridge to the solar array or any portion thereof. department access,maintenance and testing of these vents. Exception: 3111.4.8.5 Electrical 1.On structures with a PV array area of 1,000 square feet(92.90 m2)or less installed on a roof with a 3111.4.8.5.1Disconnects,Component combiner boxes or gutters shall not be located in any required pathway slope that exceeds 2:12 and with an intersecting adjacent roof and where no section is larger than 150 or cutout. feet(45720 mm)measured in length or width: 3111.4.8.5.2 Raceways on flat roofs that cross a required pathway shall be bridged to avoid tripping 1.1.Where the PV array does not exceed 25%as measured in plan view of total roof area of the hazards.Raceways shall not be permitted in required pathways on roofs with a slope that exceeds 2:12 structure,a minimum 12 inch(305mm)unobstructed pathway,shall be maintained along each side of (17-percent slope). any horizontal ridge. 1.2.Where the solar array area exceeds 25%as measured in plan view of total roof area of the structure, a minimum of one 36 inch(914 mm)unobstructed pathway from ridge to eave,over a structurally STANDOFF$ARE ATTACHED EVERY 24"IF supported area,must be provided in addition to a minimum 12 inch(305 mm)unobstructed pathway LOCATED PER C 3'OF ANY HIP,SAVE,RIDGE, along each side of any horizontal ridge. OR VALLEY PER CODE.IF OVER 3',STANDOFFS N ARE ATTACHED EVERY 48"ON CENTER. / . . . . . . / CU N a CO Y - - . '41 I I I I i 1 1 rg In Ce 111 11 1111 ak Ac bI4CONNEC,'T C wl, rNVERTER ,' i s ,i. . AC DISCONNECT METER - INTERCONNECTION ENERGY SOLUTIONS,LLC HEATHER ROMANO PO BOX 887 7977 SW CAROL ANN CT W ENERGY BEAVERCREEK,OR 97004 TIGARD OR 97224 4 503.680.3718 224.430.9389 Z `�`0 Solutions CCB#202002 7.37 KW SOLAR ARRAY-RESIDENTIAL ENLARGED ROOF PLAN 3 16' ,1' / • • 3' SUPPORTE WALK/ WAY " , " A' t f • __ _ •- !'.` " ��.' i �'. i?, i i i i f • • -_ " " " -- -- " e i " t.• I I` i i ? ! li ia, i i -- - ��' . i I i` . i. • i• . i -- -- . 29' �' i i i i i. • F. i . • " 44! i . - 0 . i n i. i rni-i i n " zn _ Q ._�_ i r zz mo i z 70- - pa n " i O Z- 'ii Z C LOWEST READING z / 13' / ' ___ MODULE END CI.AMPrX4'MANUFACTURED TRUSS , 01-1 :1-1 r ti FT!' ....------\ 1 kg ~~�N��—~I�� ' � v---= || 24"0.0. / 'MUG CLAMP --- MODULE ~--_ FLASHING / RACKING RAIL 1 '--- -.-~- �xn�_ . — _' - : 1 i w LL i i ..„..,,,„„„„,........_ S/16'SS LAG SCAN _—_ :., .=�__I IETRATION I I /l'�/F | ; I / ---.1 ( - �-- - SEALED ^~~ | I I | | / / | ( --- ~ p . y ' ~`------iill"imX ------.J ~ | Alk MO TING DETA , oz: . ,...-/'0 ,,--_.-7,,,iii0-- _ ' ___ ' — S stem Information Labels PV Module Ratings Inverter Ratings Photovoltaic DC Disconnect Module Make LG Solar Inverter Make SolarEdge Rated MPP Current = 18.4 A Module Model LG335N1C-A5 Inserter Model SE7600H-US Rated MPP Voltage = 400 V ENERGY Max Power = 335 W Max. Output Power = 7600 W Max. System Voltage = 480 V Open Circuit Voltage = 41.0 V Max. DC Voltage = 480 V Max. System Current = 30.0 A Solutions Max Power Point Voltage = 34.1 V Norminal AC Voltage = 240 V Photovoltaic AC Disconnect Short Circuit Current = 10.49 A Max.AC Current = 32 A AC Output Current = 32 A Max Power Point Current = 9.83 A 'D9.0% p P.O. Box 887 CEC Inserter Efficiency = Nominal AC Voltage = 240 V Beavercreek, Oregon 97004 Phone: 503-680-3718 Q sum, O© © p J E> 1 11 modules w/ '�\ Junction optimizers in series Box INVERTER (a(array) AC AC Main O © © �v 2i}OA AO (' Disconnect �'� Disconnect ;� OGPD I —H-- DG --—--- Unfused ----. 40AFusing 11 modules w/ (@ inverter) (@ service) I optimzers in series _ V — ��� L--- Main G Service 60 0 Pane. 0 2 Pa Sus BUILDING GROUNDING ELECTRODE EQUIPMENT SCHEDULE REF DESCRIPTION PN NOTES 1 SOLAR PV MODULE LG335N1 C-A5 LG SOLAR NEON2 335W MONOCRYSTALLNE MODULE 2 PV MODULE OPTIMIZER P370 SOLAREDGE 370W PV MODULE OPTIMIZER Nates: 3 ARRAY MOUNTHARDWARE TBD FLUSH ROOF MOUNT RACKING SYSTEM • Equipment, conductors and conduit ING 4 JUNCTION BOX TBD FOR TRANSITION FROM PV WIRE TO CONDUCTORS IN CONDUIT as listed or equivalent. 5 INVERTER SE7600H-US SOLAREDGE 7.6KW HD WAVE INVERTER W/DC DISCONNECT • Expected nominal string voltage: 6 SOLAR DISCONNECT DU222NRB SQUARED,SAFETY SWITCH,240V,60A,2-POLE,UNFUSED 400Vdc. 7 MAN SOLAR DISCONNECT D222NRB SQUARED,SAFETY SWITCH,240V,60A,2-POLE,40A FUSNG ONE LINE STANDARD ELECTRICAL DIAGRAM 8 MAIN SERVICE PANEL N/A 200A BUS W/200A MAIN BREAKER,240V(EXISTING) PROJECT REF: Heather Romano CONDUIT&CONDUCTOR SCHEDULE SITE ADDRESS: 7977 SW Carol Ann Ct,Tigard,OR REF DESCRIP./CONDUCTOR TYPE CONDUCTOR GAUGE NUMBER OF CONDUCTORS CONDUIT TYPE CONDUIT SIZE 57224 A PV-WIRE&BARE GROUND #10/#6 YSTBv1 SIZE 7.37 kW2/1 IN FREE AR 2 Strings of 11 Nodules/Optimizers(LG Solar B TIWN-2 #10/#10 4/1 EMT 3/4" 335W/SolarEdge P370) C BARE GROUND #6 1 INFREEAR e: D TI NVN 2 #81#8 3/1 pal 1" I Sheet 1 of 2 DatJanuary 3, 2018 I NOT TO SCALE PORTLAND/HILLSBORO Elev. High Temp Distance above roof Extreme ENERGY 0.4% 2%-Avg. 0.5" 3.5" 12" Min 62 m 37 °C 32 54°C 49 °C 46 °C -8 °C Solutions Correction Temperatures Voltage Drop calculations: AT° =-8°C-25°C=-33°C OTho,=(37°C+35°C)-25°C=47°C PV Nominal String Voltage: 400Vdc P.O. Box 887 Flush Roof Mount PV MPPT String Current: 335W x 15+400V=12.6A Beavercreek, Oregon 97004 Phone: 503-680-3718 DC conductor run is 65 ft(estimated) Module Voltage Calculations DC Voltage Drop LG Solar Neon2 335W(LG335N1C-A5) (2 x 65ft x 12.6A x 1.24O/kft x 100)/(1000ftJkft x 400V)=0.51% Voc=41.0V Vmp=34.1V Voc Temp Coefficient=-0.27%/°C lsc= 10.49A Imp=9.83A Pmax Temp Coefficient=-0.37%/°C Inverter Output is 240Vac, 32A AC conductor run is 15 ft(estimated) Cold Voc=41.0V+(41.0V x-0.27%/°C x-33°C)=41.0V+3.65V=44.7V AC Voltage Drop Hot Vmp=34.1V+(34.1V x-0.37%/°C x 47°C)=34.1V-5.93V=28.2V (2 x 15ft x 32.0A x 0.778Q/kft x 100)/(1000ft/kft x 240V)=0.31% SolarEdge P370 Optimizer Max Input DC Power: 370W Max Input DC Voltage: 60V Notes: MPPT Operating Range: 8-60V Max Input lsc Current: 11A • Ampacity calculations from array to inverter based on 4 current- Maximum DC Output: 15A Min/Max Input String Length: 8/25 carrying conductors in conduit. SolarEdge SE7600H-US Inverter • Interconnection to the main service via a line-side tap to the Max DC Input(V):480V Max DC Input(A): 20.0A supply conductors in the MSP or Meter Base(as appropriate). Nominal DC Input: 400V Max Power per String: 6000W Complies with 705.12. Output voltage: 240Vac Max Output current: 32.0A • Conductor sizing listed is minimum required based on NEC ampacity calculations for CU conductors. String Sizing • PV System to be installed and labeled per National Electric Code. 11 x 335W=3685W Specifically: Label Calculations -690.4(D) -690.31(B) MPPT DC Current: -690.5(C) -690.35(C)and(F) 335W x 22+400V= 18.4A -690.13(8) -690.5(C) -690.17(E) -705.12(D) Conductor Amoacity.OCPD&Disconnects • All equipment used UL listed. Optimizer Output Circuit: • Equipment, conductors and conduit as listed or equivalent. 15A x 125%= 18.8A(continuous duty) • Inverter listed to UL-1741 for grid-interactive use and GFDI 18.8A+ 1.00= 18.8A(PV Wire in free air) #12 AWG(rated for 35A into 75°C terminals in free air) protection. #10 AWG selected for compliance with installation instructions 18.8A+0.8+0.76=30.9A(conditions of use-temp and conduit fill) #10 AWG(rated for 35A into 75°C terminals) No fusing required. Only two strings and each lands on dedicated terminals. DC Disconnect functions integral to inverter. ELECTRICAL CALCULATIONS PROJECT REF: Heather Romano Inverter Output Circuit: 32.OA x 125%=40.OA SITE ADDRESS: 7977 SW Carol Ann Ct,Tigard,OR #8 AWG(rated for 50A into 75°C terminals and required OCPD) 97224 SI40A Fusing in a 60A,240V,2-Pole, Fused AC Disconnect at the Service SYSTEM of 1 7.37 kWEntrance. 2 Strings of 11 Modules/Optimizers(LG Solar 335W/SolarEdge P370) An additional unfused AC Disconnect is located adjacent to the inverter. Sheet 2 of 2 Date: January 3, 2018 RON RI DGE Flash Foot 2 (3.56) Li wi ( 1.02) I (3.67) 'e r 'S ®o a , i THIS EDGE TOWARDS ROOF RIDGE (---- ---'s 1 Q • I ( 12.00) ` �i I y L_1i f � (3.00) - > i �— --- -(4.50} "— -' ( 9.00) — NO. PART NUMBER DESCRIPTION QTY. 1 FM-100-006 ASSY, FLASHING, MILL 1 2 FM-100-008 ASSY, CAP, MILL 1 SCREW, LAG, HEX, 5/16. WI 3 23-3118-475LGF CUSTOM HEAD, 7/16 HEX W/ 1 KIT, FLASHFOOT 2 FLANGE 4.75L SIZE DO NOT SCALE DRAWING 'BiN 4of mat25-3erials shown102for—ODDsingle SFlash Foot 2 WASHERbl , EPDM BACKED A 1 SCAIF 14 I WEIGHT:0,88Rx I SHFFT I OF I is a assemy. 0 2016 IronRidge,Inc.All rights reserved.Visit www.ironridge.com or call 1-800-227-9523 for more information. FM-FF2-MAN REV 1.0 Installation Tools Required:tape measure, chalk line, stud finder, roofing bar, caulking gun, driver with 1/4" bit and 7/16" hex socket. U .. 3rd 1 — L —_..__ I I 3rd course ! , i I I t--i----Rifter i 1 r l l j i ' I II ,, , , _'1-_ L — ! ,2nd course I 1 ' T - ! 1 y 1' ; 1 1j �' j i ...z , ' lit course t Locate rafters and snap vertical and horizontal lines Slide flashing, between 1st and 2nd course, so the to mark flashing locations. Drill 1/4" pilot holes, then top is at least 3/4"above the edge of the 3rd course fill with roofing manufacturer's approved sealant. and the bottom is above the edge of the 1st course. Line up pilot hole with flashing hole and insert lag Place Cap onto flashing in desired orientation for bolt with bonded washer through flashing. Tighten E/W or N/S rails and rotate 180 degrees. FlashFoot lag bolt until fully seated. 2 is now installed and ready for IronRidge XR Rails. Iri - r Structural Certification Designed and Certified for Compliance with the International Building Code&ASCE/SEI-7. Water Seal Ratings Water Sealing Tested to UL 441 Section 27'Rain Test"and A TAS 100-95 Wind" Driven Rain Test"by Intertek. Ratingsapplicable for composition shingle roofs having slopes _ _ -` -- between 2.12 and 12:12. UL 2703 Conforms to UL 2703 Mechanical and Bonding Requirements. See IronRidge Flush Mount Installation Manual for full ratings. Attach rails to either side of the open slot using bonding hardware. Level rail at desired height, then torque to 250 in-lbs (21 ft-lbs). 0 2016 IronRidge,Inc.All rights reserved.Visit www.ironridge.com or call 1-800-227-9523 for more information. FM-FF2-MAN REV 1.0 Datasheet liwAp.,. IRON RIDGE Flush Mount System ., z} hj ',rw r m is x x' ^ ',,.' ¢ u it for solar's solar' toughest roofs. IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. 3r ri Strength Tested r ,-. PE Certified All components evaluated for superior r p p Pre-stamped engineering letters . . t:4 structural performance. �-.. available in most states. 6 Class A Fire Rating Design Assistant Certified to maintain the fire resistance Online software makes it simple to ,. ., rating of the existing roof. create, share, and price projects. UL 2703 Listed System r k h �{ �� � Y ,:'16.140,)''''I'',.:::. 20-Year Warranty Entire system and components meet ,-,,,,,,:!,‘,..—.44.,,, �: Y P Twice the protection offered by newest effective UL 2703 standard. ,,, competitors. Da asheet ._—_ XR Rails .____ _____ __ _ __ . . _. ___a__ _____ . ,__._______._v ___ ._ .,. XR10 Rail XR100 Rail XR1000 Rail Bonded Splices i I 4 . A low-profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections. • 6'spanning capability • 8'spanning capability • 12'spanning capability • Self-drilling screws • Moderate load capability • Heavy load capability • Extreme load capability • Varying versions for rails • Clear&black anod.finish • Clear&black anod.finish • Clear anodized finish • Forms secure bonding i, UFOs Stopper Sleeves Grounding Lugs Microinverter Kits Ap A la Universal Fastening Objects Snap onto the UFO to turn Connect arrays to Mount MIs or POs to XR bond modules to rails. into a bonded end clamp, equipment ground. Rails. • Fully assembled&lubed • Bonds modules to rails • Low profile • Bonds devices to rails • Single, universal size • 6 different sizes • Single tool installation • Kit comes assembled • Clear&black finish • Clear&black anod.finish • Mounts in any direction • Listed to UL 2703 _.,..-_._ Att c m is .., ___ ...e...__._ _ ,- ___�_ �_ ___ �__ . -� _____ _,____ ._.._._..___________ n ___ _ __m._ _.__..n.__ FlashFoot2 Slotted L-Feet Bonding Hardware Flush Standoffs ,s,,,is "'*, tF`''',.$ Fes* Flash and mount XR Rails Drop-in design for rapid rail Bond and attach XR Rails Raise Flush Mount System with superior waterproofing. attachment. to certified attachments. to various heights. • Twist-on Cap eases install • Secure rail connections • T&Square Bolt options • Works with vent flashing • Wind-driven rain tested • Slot for vertical adjusting • Nut uses 7/16"socket • 4"and 7"lengths • Mill&black finish • Clear&black anod.finish • Assembled&lubricated • Ships assembled . _ .... . , ,.... ____ _.._ ___z.._._ ., __ ._....__. _.. . __ ..,__. .,_. ,.._.._.. _.__.. .....,,_.. :sign Assistant X-;.,1,,-;,,,,-,,,\ NABCEP Certified Training I s,► 6a ,,,, ::::1 from rough layout to fully l '„: fit`,, Earn free continuing education credits, gineered system. For free. while learning more about our systems. \.. , ) irortR:k:ty.acorn dc,-Ag i. li`Cilimi,lrgt.C.01T4iIral ilViii l * WC.AN rights rtoaervoli MO wwwjAmrkige.00ro or call 1.4100-227,96,23 f#t more stfor tion.Version 1.20 ii,C.L.7 LG Innovation for Life's Good a Better Life * .t. 46 4 # _ -4 4 14 44 44 4 • 4 .6 4 • 444 .6 16 446 . . 44 4 46 4 4. . LG NeONE 2 LG335N1C-A5 LG's new module,LG NeONTM 2,adopts Cello technology. Cello technology replaces 3 busbars with 12 thin wires T AFYRCve FocUQ /� to enhance power output and reliability.LG NeONTM 2 i OVE c(1 us c E ' V 0 / Cell demonstrates LG's efforts to increase customer's values cell beyond efficiency.It features enhanced warranty,durability, Intertek performance under real environment,and aesthetic design suitable for roofs. 111111 k Enhanced Performance Warrantynr1711; High Power Output LG NeONT" 2 has an enhanced performance warranty. Compared with previous models,the LG NeONT"^2 The annual degradation has fallen from-0.6%/yr todNo anbeen designed to significantly enhance its output -0.55%/yr.Even after 25 years,the cell guarantees 1.2%p efficiency,thereby making it efficient even in limited space. more output than the previous LG NeONTM 2 modules. 111111 Aesthetic Roof Outstanding Durability LG Ne0NT""2 has been designed with aesthetics in mind; 111111 1 With its newly reinforced frame design,LG has extended i ill/ thinner wires that appear all black at a distance, 1 the warranty of the LG NeONTM 2 for an additional The product may help increase the value of 2 years.Additionally,LG NeONT"2 can endure a front a property with its modern design. load up to 6000 Pa,and a rear load up to 5400 Pa. • • • 111111.0. Better Performance on a Sunny Day Double-Sided Cell Structure • • • LG NeONTM'2 now performs better on sunny days thanks The rear of the cell used in LG NeONTM 2 wilt contribute to to its improved temperature coefficiency. generation,just like the front;the light beam reflected from the rear of the module is reabsorbed to generate a great amount of additional power. About LG Electronics LG Electronics is a global player who has been committed to expanding its capacity,based on solar energy business as its future growth engine.We embarked on a solar energy source research program in 1985,supported by LG Group's rich experience in semi-conductor,LCD,chemistry,and materials industry We successfully released the first Mono Xi'l series to the market in 2010,which were exported to 32 countries in the following 2 years,thereafter.In 2013,LG NeON'"(previously known as Mono X®NeON)won"Intersolar Assard';which proved LG is the leader of innovation in the industry. LGNeON 2 LG3351\11C—A5 Mechanical Properties Electrical Properties(STC*) Cells 6 x 10 Module LG335N1 C-A5 Cell Vendor LG Maximum Power(Pmax) 335 Cell Type MonocrystaUine I N-type MPP Voltage(Vmpp) 34.1 Cell Dimensions _ 161.7 x 161.7 mm/6 inches _ MPP Current(lmpp) 9.83 a of Busbar 12(Multi Wire Busbar) Open Circuit Voltage(Voc) 41.0 Dimensions(L x W x H) 1686 x 1016 x 40 mm Short Circuit Current(Isc) 10.49 66.38 x 40 x 1.57 inch Module Efficiency 19.6 Front Load 6000Pa Operating Temperature -40-+90 Rear Load 5400Pa Maximum System Voltage 1,000 Weight 18 kg Maximum Series Fuse Rating 20 Connector Type MC4 Power Tolerance(%) 0-+3 Junction Box IP68 with 3 Bypass Diodes *STC(Standard Test Condition)Irradiance 1,000W/nC,Ambient Temperature 25°C,AM;s hiThe nameplate power outputs measured and determined by COElectronics Sias sole and absolute discretion 1000 mm x 2 ea *The Typical change in module efficiency at 200 W/rn'In relation to 1000 W/m2 is-2.0%. Glass High Transmission Tempered Glass Frame Anodized Aluminium Electrical Properties(NOCT*) Certifications and Warranty Module LG335N1 C-A5 Certifications IEC 61215,IEC 61730-1/-2 Maximum Power(Pmax) 247 UL 1703 MPP Voltage(Vmpp) 31.5 IEC 61701(Salt mist corrosion test) MPP Current(lmpp) 7.83 IEC 62716(Ammonia corrosion test) Open Circuit Voltage(Voc) 38.2 ISO 9001 Short Circuit Current(Isc) 8.44 Module Fire Performance(USA) Type 1 *NOCT(Nominal operating Cell Temperature)Irradiance eoaw/mE,ambient temperature 20=C,wind speed 1m/s Fire Rating(CANADA) Class C(ULC I ORD C1703) Product Warranty 12 years Output Warranty of Pmax Linear warranty** Dimensions(mm/in) -- ,n50 year:98%,2)Aker 2nd yearSS%annual degradation,3)25 years 84.8% sro.3 $ LJ Temperature Characteristics of , CH ,, ,, no, Emig NOCT 45±3°C ocain u,,,, Pmpp -0.37%/5C Voc -0.27%/°C Isc 0.03%/°C °' P=�:i`1 Characteristic Curves 00��' rso,63' rib in y., 1 000w 800W -- 600W °xio asp 400W \ / n 200W s s - - 21 LG North America Solar Business Team Product specifications are;object to change without notice. \�...L,^�' CO Electronics U.S.A.Inc Life's Good 1000 Sylvan Ave,Englewood Cliffs,NJ 07632 . -1.° j Copyright O 2017 LG Electronics.A))rights reserved. Innovation for a Better Life .1.11, ,'"..1..Valid Contact lg.solar@Ige.com ` 01/01/2017 41(44.11S . www(gsolarusa.com i = ,J.Q CIr, I. ------- , C/) solar - • • ::- cr LLJ SolarEdge Single Phase Inverters I--- cri for North America LU SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / > SE7600H-US ZIP — ' - ' ' • - - - - -- , . „ ,, , , 4. , ,, ,r , ,,. .,,, ,,,,.. „, —-„ • „. , ,- , , -, - ,- , ,. -,_„. „_„, --, ..,,,, „ -,, ' ' ' ' - .--e,.,-,„ . ,,,.„ , . ,„,. ,,- , , .., , • , ., , . , , • a', ' vi'' .„'' -fc=',N.,,-.,,,,i,,'4,::,,,,,. _ . . . . . ., , ,,,. -.• -. ,,.,„, . ,. . ,, „ - • v. a,, , . v -#' ' , . , , • v , , v , • / ^. • ' . t • , . ,• ,t„ • a, ' l , • ,,s. •, , , t , ,, a . • r.'. , • ^ • ^ ' •..• , • , , ^'',,. . ... ' ,,, ..,,, . ..• ^ ^ ' • , , ^ Optimized installation with HD-Wave technology - AP Specifically designed to work with power optimizers lir Record-breaking efficiency - Integrated Arc Fault protection and Rapid Shutdown for NEC 2017,690.11 and 690.12 i. II iirli Extremely small inmon rit tio •.. High reliability without any electrolytic capacitors •• Built-in module-level monitoring wave .- Outdoor and indoor installation -. Optional:Revenue grade data,ANSI C12.20 Class 0.5(0.5%accuracy) i.2SA-CANADA 6ERNIANY i fAlY-FRANCE iAPAN SJ-1AA-AUSTRALiA-7HE NE1HER1..ANDS-UK-P,RAEL-ILIRKIY-SOUrH AFRICA-BcHGARIA www.solaredge,us solar _ • • ! Single Phase Inverters for North America SE3000H-US I SE3800H-US/SE5000H-US!SE6000H-US/SE7600H-US SE3000H-US 1 SE3800H-US ! SE5000H-US SE6000H USSE7600H US OUTPUT Rated AC Power Output 3000 3800 I 5000 .6000 __ 7600 VA Max.AC Power Output 3000 3800 5000 ... ., .....6000 7600 VA._.. AC Output Voltage Min.-Nom.-Max.(183-208-229) - ✓ I .. ,... .. ., . . . .. . ., . ,.... Vac AC Output Voltage Min.-Nom.-Max.(211 240-264) ✓ ✓ ✓ ✓ V Vac AC Frequency(Nominal) 59.3-60-60.51- Hz Maximum Continuous Output Current 208V - , 24 A Maximum Continuous Output Current 240V 12.5 16 21 I 25 i 32 A GFDI Threshold1 A ,... Utility Monitoring,Islanding Protection, Yes Country Configurable Thresholds INPUT Maximum DC Power 4650 I.. 5900 7150 9300 11800 W Transformer-less,Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current 208V 15.5 ! I - Adc Maximum Input Current 240V ..,..,...,,._ ... .. ...... ... 85.,......, ... ...10.5.... ......,...,13.5 16.5 . .. 20,.,. ,... ...Adc_... Max.Input Short Circuit Current 45 Adc Reverse Polarity Protection Yes Ground-Fault Isolation Detection 600k<>Sensitivity Maximum Inverter Efficiency 99 % ..-.. ..,., 99.2 CEC Weighted Efficiency 99 ...,. Nighttime Power Consumption <2.5 W ADDITIONAL FEATURES Supported Communication Interfaces RS485,Ethernet,ZigBee(optional),Cellular(optional) Revenue Grade Data,ANSI C12.20 Optional('),. Rapid Shutdown NEC 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE - Safety UL1741,UL1699B,CSA C22.2,Canadian AFC'according to T.I.L.M-07 Grid Connection Standards IEEE1547,Rule 21'3? Rule 14(HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS. AC Output Conduit Size/AWG Range 0.75-1" Conduit/14-6 AWG DC Input Conduit Size/#of Strings/AWG Range 0.75-1" Conduit/1-2 strings/14-6 AWG Dimensions with Safety Switch(HxWxD) 17.7 x 14.6 x 6.8 /450 x 370 x 174 in/mm /., Weight with Safety Switch 25.3/11.5 lbkg Oise <25 dBA Cooling Natural Convection Operating Temperature Range 13 to+,140/!-25 to+6001(:40:F/ 40°C option)t51 °F/°C Protection Rating NEMA 3R(Inverter with Safety Switch) 1')For other regional settings please contact SolarEdge support ,21 Revenue grade inverter P/N:SExxxxH-U5000NNC2 (3,Pending certification '0'Power de-rating from 50,C 151-40 version P/N:SExxxxH-US000NNU4 (III [ Uf... RoHS , ,..'IS" I h..^it„ _ -.I -Du II,, , I,,C e_I,,,. , I,111 D i _,,,_%,LDGE al rr,uomarl a.5[c_Ji,3Jema 4 S.1a'Edg,Icchnc-I kit c.Inc.911 th^r it.2;'ual:s `".:::n I;n:d hici,: -I ,aFIs ti--,.- e•=;arm I).,•.,: l 22L 5 5ub,,c!, „Ila .n I II i .Sae. solar • • f'Nsi ....... SolarEdge Power Optimizer ....... Module Add-On For North America i...... P320 / P370 / P400 / P405 ';.:ii.,,,,,(4e,,r!,;xro?yA54i,YAga4w,"iffPtwRoP4gWgit-AIARgorigrAgioogAktvoas,4#6tggoailgkf.at! w,ito2:t:.3,,,o,:aw,4:,K,z,,,to*oat,t-A4.,,Egtwiptme.-*.4tKse-vr4.,4'tteg65-yprpfr.totgtievaoltistt- -,1,01,:ro?,a-poys4gonflomyoipotAsi4,4,44,A44fazigoitoot4;se--rz:og,twAttoo-oog; ULJ x:x:'rr,;*i'6'r.,ir:,f-s2:nfimgettttf0-is:-ia-zoqrgg*.xqittkvek,aoAtiited,,c:f::'tgtRqtt 'AEx.L.:rv:',,v;--x-pggog,ixxot;-„ti,,p4v4kot*:,ozo-'4vi:,xv4ogsr Ifirgtox* CI_ 4,63' 7.4 * ,;;;, "(ilk''"•rit:;g0-;Wri,0050.0' gAttatiAtO • . :•- .• , . • . PV power optimization at the module-level •-- •-• ••:* • - • • SPecificallydesigned,to workiwith.S0largdoeinverterS1-- •._ '„ : _•••.- ' • , • • •• Up to 25%More energy , - • , , - , ,, Superior efficiency(99.5%) • • , • - • - - , r Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading — Flexible system design for maximum space utilization - • -. Fast installation with a single bolt • Next generation maintenance with module-level monitoring • Compliant with arc fault protection and rapid shutdown NEC requirements(when installed as part of the SolarEdge system) • Module-level voltage shutdown for installer and firefighter safety USA-CANA1A GERMANV ITALY-FRANCE-iAPAN-CHNA-AUSTRAi PA THE NETHERLANDS-UK-ISRAEL-TURKEY-SOUTH AFRiCA BULGARIA-INDA www.soiaredge.os SO I a r ' O • IIIII SolarEdge Power Optimizer Module Add-On for North America P320/ P370/ P400/ P405 OPTIMIZER MODEL P320 i P370 P400� !`^ ' P405` ^' (for high-power (for higher-power (typical module compatibility) 60 and 72-cell $ (for 72&96-cell ( - (for thin film S 60-cell modules) modules) j modules) INPUT modules) Rated Input DC Power 320 370 400 405 W Absolute Maximum Input Voltage ••- (Voc at lowest temperature) 60 80 125 Vdc 48 MPPT Operating Range 8 48 8 608 80 12.5 105 Vdc Maximum Short Circuit Current(Isc) 11 Adc Input13 75 MaximumDC Current .., ... ....... ............. ... .. ... 12.63 ' Maximum Efficiency Adc __..-. 99.5 Weighted Efficiency ,.... .... ........ . ......... 98.8.. .. Overvoltage Category II OUTPUT DURING OPERATION(POWER OPTIMIZERCONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 i-- — - Adc Maximum Output Voltage �°"" ...-•. 60 _ L 85 Vdc OUTPUT:DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power do Optimizer 1±0.1 Vdc ___ --_-- - Y _ _ ._ STANDARD COMPLIANCE EMC FCC Part15 Class B,IEC61000 6 2,IEC61000-6-3 Safety IEC62109-1(class II safety),UL1741 RoHS Yes INSTALLATION SPECIFICATIONSMaximum Allowed System Voltage 1000 Vdc Compatible inverters v r All SolarEdge Single Phase and Three Phase inverters Dimensions(WxLxH) 128x152x28/5x5.97x1.1 128x152x36/ i 128x152 x50/ 5x5.97x1.42 5x5.97x1.96 mm/in Weight .. .. j ..,... _, _.,... g. including cables) 630/1.4 750/17. 845//1.9 gr//lb Input Connector MC4 Compatible MC4/ MC4 Compatible Amphenol AH4 I Double Insulated;MC4 Double Insulated• Output Wire Type/Connector Com alible MC4/ Double Insulated;MC4 Compatible p Amp henol AH4 ..Output Wire Length 0.95/3 0 ., 1 ./ 9 m/ft 2 Operating Temperature Range. -40-+85/-40 C JeF +185 3 .- .. .1 Protection Rating _. .. I P68(N E MA6P Relative Humidity 0 100 1,..,... Relative... . ..,,... ... '�l power of the module.Module of up to+5%power tolerance allowed PV SYSTEM USING —__ ___-.---_.__ _. SINGLE PHASE --- -_---.--- ______ PV A SOLAREDGE DESIGN TERilil3i HD WAVE SINGLE PHASE THREE PHASE 208V THREE PHASE 480V —_._. ,_.__ -1_.._ Minimum String Length P320,P370,P400 I 18 --^- -•------- 8 � (Power Optimizers) P405 6 10 8 14 Maximum String Length ........ .,. (Power pptimizers) � 25 i 25 i 50141 5700(6000 with Maximum Power per String 5250 6000 12750 W SE7600H US) Parallel Strings of Different Lengths or Orientations Yes z For detailed string sizing information refer to nttp.(/www solaredge.comJsites/default/filesJstnng s¢mg na.pdf. I"It is not allowed to mix P405 with P320/P370/P400/P600/P700/P800 In one string. 14)A string with more than 30 optimizers does not meet NEC rapid shutdown requirements;safety voltage will be above the 30V requirement C E ETA I:•E r,-.I, -- I.) .Il h. Y-:c-. 1 JG LA:,t I)I L the Sc Iit s;I,., -t 1141I'[Is by t__AREr,GL 1^Ia l >t r U r,Bra larL.—,S-i d,n'ei hr I Inc :311 thrr tiaa marks mr tl .;d he,,,in,,rE